WorldWideScience

Sample records for resolution nuclear microprobe

  1. Effect of magnetic quadrupole lens alignment on a nuclear microprobe resolution

    International Nuclear Information System (INIS)

    Kolinko, S.V.; Ponomarev, A.G.

    2016-01-01

    The paper reports the research trends in developing probe-forming systems with high demagnification and analysis factors that limit a nuclear microprobe resolution. Parasitic aberrations caused by tilts and offsets of magnetic quadrupoles are studied in terms of their effect on probe parameters on a target. The most common arrangements of probe-forming systems such as a triplet and “Russian quadruplet” with separated geometry are considered. The accuracy prerequisites for the positioning of the quadrupoles are defined, and practical guidelines for alignment of probe-forming systems with high demagnification factors are suggested.

  2. An extended magnetic quadrupole lens for a high-resolution nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Breese, M.B.H. E-mail: m.breese@surrey.ac.uk; Grime, G.W.; Linford, W.; Harold, M

    1999-09-02

    This paper describes the design requirements and initial performance of a new style of magnetic quadrupole lens for use in a high-resolution nuclear microprobe, which is presently being constructed in Oxford. Such a microprobe necessitates the use of a small image distance from the exit face of the final quadrupole lens to the image plane in order to produce a large demagnification. This means that the final lens should be as close to the sample chamber as possible. However, with conventional magnetic quadrupoles the current-carrying coils protrude by a typical distance of 10-20 mm beyond the pole face, thereby significantly limiting the minimum image distance. The approach taken here is to recess the coils into the body of the lens, so that they are almost flush with the pole pieces and lens yoke, enabling an image distance of 55 mm. Three-dimensional magnetic field calculations within this lens structure predict that the field in the extended pole piece 'nose' region is only slightly less than that in the main lens body. Experimental field profiles, measured using a Hall probe, are used to confirm these calculations.

  3. An extended magnetic quadrupole lens for a high-resolution nuclear microprobe

    International Nuclear Information System (INIS)

    Breese, M.B.H.; Grime, G.W.; Linford, W.; Harold, M.

    1999-01-01

    This paper describes the design requirements and initial performance of a new style of magnetic quadrupole lens for use in a high-resolution nuclear microprobe, which is presently being constructed in Oxford. Such a microprobe necessitates the use of a small image distance from the exit face of the final quadrupole lens to the image plane in order to produce a large demagnification. This means that the final lens should be as close to the sample chamber as possible. However, with conventional magnetic quadrupoles the current-carrying coils protrude by a typical distance of 10-20 mm beyond the pole face, thereby significantly limiting the minimum image distance. The approach taken here is to recess the coils into the body of the lens, so that they are almost flush with the pole pieces and lens yoke, enabling an image distance of 55 mm. Three-dimensional magnetic field calculations within this lens structure predict that the field in the extended pole piece 'nose' region is only slightly less than that in the main lens body. Experimental field profiles, measured using a Hall probe, are used to confirm these calculations

  4. Materials analysis with a nuclear microprobe

    International Nuclear Information System (INIS)

    Maggiore, C.J.

    1980-01-01

    The ability to produce focused beams of a few MeV light ions from Van de Graaff accelerators has resulted in the development of nuclear microprobes. Rutherford backscattering, nuclear reactions, and particle-induced x-ray emission are used to provide spatially resolved information from the near surface region of materials. Rutherford backscattering provides nondestructive depth and mass resolution. Nuclear reactions are sensitive to light elements (Z < 15). Particle-induced x-ray analysis is similar to electron microprobe analysis, but 2 orders of magnitude more sensitive. The focused beams are usually produced with specially designed multiplets of magnetic quadrupoles. The LASL microprobe uses a superconducting solenoid as a final lens. The data are acquired by a computer interfaced to the experiment with CAMAC. The characteristics of the information acquired with a nuclear microprobe are discussed; the means of producing the beams of nuclear particles are described; and the limitations and applications of such systems are given

  5. Nuclear scanning microprobe: state of the art, applications and progress trends

    International Nuclear Information System (INIS)

    Ponomarev, A.G.

    2011-01-01

    The physical principles of nuclear scanning microprobe are considered. The analysis of state of the art of the microprobe setup from point of view of its spatial resolution and sensitivity of microanalysis techniques is given. The regions of nuclear microprobe applications are reviewed. The ways of spatial resolution and data acquisition system improvement under consideration of microprobe setup progress trends are considered. (authors)

  6. New generation nuclear microprobe systems

    International Nuclear Information System (INIS)

    Jamieson, David N.

    2001-01-01

    Over the past 20 years, the minimum probe size for nuclear microscopy has stayed around 1 μm with only a few groups reporting a sub-micron probe size around 0.5 μm. No breakthroughs in nuclear microprobe design have been forthcoming to produce dramatic improvements in spatial resolution. The difficulties of breaking the constraints that are preventing reduction of the probe size have been well recognised in the past. Over the past 5 years it has become clear that some of these constraints may not be as limiting as first thought. For example, chromatic aberration clearly is not as significant as implied from first-order ion optics calculations. This paper reviews the constraints in view of the increased understanding of the past 5 years and looks at several new approaches, presently being evaluated in Melbourne and elsewhere, on how to make progress. These approaches include modified RF ion sources for improved beam brightness and exploitation of relaxed constraints on some lens aberrations allowing the use of high demagnification probe forming lens systems

  7. Biomedical application of the nuclear microprobe

    International Nuclear Information System (INIS)

    Lindh, U.

    1987-01-01

    The Studsvik Nuclear Microprobe (SMP) has mainly been devoted to applications in the biomedical field. Its ultimate resolution is reached at 2.9x2.9 μm 2 with a proton current of 100 pA. With this performance the SMP has been used in a wide range of disciplines covering environmental hygiene, toxicology, various aspects of internal medicine and trace element physiology. Examples of recent applications in these fields are described. (orig.)

  8. Chemical history with a nuclear microprobe

    International Nuclear Information System (INIS)

    Maggiore, C.J.; Benjamin, T.M.; Burnett, D.S.; Hyde, P.J.; Rogers, P.S.Z.; Srinivasan, S.; Tesmer, T.; Woolum, D.S.

    1983-01-01

    A nuclear microprobe cannot give direct information on the chemical state of an element, but the spatial distribution of elements in a specimen is often determined by the chemical history of the sample. Fuel cells and minerals are examples of complex systems whose elemental distributions are determined by past chemical history. The distribution of catalyst in used fuel cell electrodes provides direct information on the chemical stability of dispersed catalysts under operating conditions. The authors have used spatially resolved Rutherford backscattering to measure the migration of platinum and vanadium from intermetallic catalysts and to determine their suitability for use under the extreme operating conditions found in phosphoric acid fuel cells. Geologic materials are complex, heterogeneous samples with small mineral grains. The trace element distribution within the individual mineral grains and between different mineral phases is sensitive to the details of the mineral formation and history. The spatial resolution and sub-100-ppm sensitivity available with a nuclear microprobe open up several new classes of experiments to the geochemist. Geochemistry and electrochemistry are two areas proving particularly fruitful for application of the nuclear microprobe

  9. Biological analysis with a nuclear microprobe

    International Nuclear Information System (INIS)

    Cookson, J.A.; Legge, G.J.F.

    1975-01-01

    Most low-energy nuclear accelerators are now partly used on analytical studies in support of sciences other than nuclear physics. This paper gives a short review of such analytical techniques (X-ray analysis, elastic scattering analysis, nuclear reaction analysis, and the nuclear microprobe) with particular reference to biological applications and also emphasizes the role of the positional analysis that can be performed with a focused beam of ions - the nuclear microprobe. (author)

  10. Extraterrestrial materials examined by mean of nuclear microprobe

    Science.gov (United States)

    Khodja, H.; Smith, T.; Engrand, C.; Herzog, G.; Raepsaet, C.

    2013-07-01

    Comet fragments, micrometeorites, and Interplanetary Dust Particles (IDPs) are small objects (purpose, we need instruments and methods that provide both microanalysis and detailed imaging. In these respects, the nuclear microprobe offers many potential advantages: (i) the spatial resolution, ∼1 μm is well-matched to the typical object dimensions, (ii) with some reservations, it is non-destructive when carefully conducted, (iii) it is quantitative, and especially sensitive for light elements. At the Saclay nuclear microprobe, we have been performing analyses of extraterrestrial objects for many years. We review some of these studies, emphasizing the specific requirements for successful analyses. We also discuss the potential pitfalls that may be encountered.

  11. Novel imaging techniques for the nuclear microprobe

    International Nuclear Information System (INIS)

    Saint, A.

    1998-01-01

    Many of the developments of the scanning electron microscope (SEM) have been paralleled during the development of the scanning nuclear microprobe. Secondary electrons were used in the early development of both devices to provide specimen imaging due to the large numbers of secondaries produced per incident charged particle. Other imaging contrast techniques have also been developed on both machines. These include X-ray analysis, scattering contrast, transmission microscopy, channelling induced charge and others. The 'cross-section dependent' imaging techniques such as PIXE, RBS, NRA, etc., rely on the beam current on target for a given resolution. This has prompted research and development of brighter ion sources to maintain probe resolution at high beam current. Higher beam current bring problems with beam damage to the specimen. Low beam current techniques however rely on high countrate data collection systems, but this is only for spectroscopy. To produce an image we can increase beam currents to produce live-time images for specimen manipulation and observation. The work presented here will focus on some developments in live-time imaging with a nuclear micro probe that have taken place recently at the School of Physics, Microanalytical Research Centre (MARC), University of Melbourne

  12. The upgraded Amsterdam nuclear microprobe

    International Nuclear Information System (INIS)

    Vis, R.D.; Kramer, J.L.A.M.; Tros, G.H.J.; Langevelde, F. van; Mars, L.

    1993-01-01

    The improvement of the facilities at our University consists of three phases. In phase 1, a 1.7 MV NEC tandem-Pelletron accelerator has been installed. The accelerator serves as injector for two beam lines, subsequently for macro- and micro-analysis. Moreover, an interconnection has been made with a beam line from our 400 kV high voltage Van de Graaff accelerator in order to enable injection of these very intense low energy beams in these two lines. Apart from new vacuum equipment and conventional beam steering and focussing elements, the experimental facilities are replaced from the cyclotron experimental hall to the newly organised experimental hall. In the phases 2 and 3, which are not yet completed, a second ion source for the Pelletron and a new or extended focussing unit for the microprobe will complete the overall operation. (orig.)

  13. The new nuclear microprobe at Livermore

    International Nuclear Information System (INIS)

    Roberts, M.L.; Bench, G.S.; Heikkinen, D.W.; Morse, D.H.; Bach, P.R.; Pontau, A.E.

    1994-10-01

    Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories/California have jointly constructed a new nuclear microprobe beamline. This beamline is located on the LLNL 10 MV tandem accelerator and can be used for multidisciplinary research using PIXE, PIGE, energy loss tomography, or IBS techniques. Distinctive features of the beamline include incorporation of magnet power supplies into the accelerator control system, computer controlled object and image slits, automated target positioning to sub-micron resolution, and video optics for beam positioning and observation. Mitigation of vibrations was accomplished with vibration isolators and a rigid beamline design while integral beamline shielding was used to shield from stray magnetic fields. Available detectors include a wavelength dispersive X-ray spectrometer, a High-Purity Germanium detector (HPGe), a Lithium-Drifted Silicon X-Ray detector (SiLi), and solid state surface barrier detectors. Along with beamline performance, results from recent measurements on determination of trace impurities in an International Thermonuclear Experimental Reactor (ITER) super conducting wire strand, determination of Ca/Sr ratios in seashells, and determination of minor and trace element concentrations in sperm cells are presented

  14. Mixed beams for the nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Breese, M.B.H.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Recently the Micro-Analytical Research Centre (MARC) at Melbourne University has developed a technique to provide mixed beams of ions for a magnetically focussed nuclear microprobe. Such a mixed beam is defined as two (or more) beams of different species ions that can quickly and easily be made to have the same magnetic rigidity R{sub m} = (mE/q{sup 2}) and therefore be transported, focused and scanned the same in a magnetic nuclear microprobe. The production of mixed beams in an electrostatically focussed micro- probe have already been demonstrated. This paper will show how mixed beams can be produced on a single-ended accelerator. Indications of how to produce them on a tandem will also be given. Applications of these mixed beams in micro-lithography, scanning transmission ion microscopy (STIM) imaging and ion beam induced charge (IBIC) imaging will also be presented. 3 refs., 3 figs.

  15. Mixed beams for the nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A; Breese, M B.H.; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Recently the Micro-Analytical Research Centre (MARC) at Melbourne University has developed a technique to provide mixed beams of ions for a magnetically focussed nuclear microprobe. Such a mixed beam is defined as two (or more) beams of different species ions that can quickly and easily be made to have the same magnetic rigidity R{sub m} = (mE/q{sup 2}) and therefore be transported, focused and scanned the same in a magnetic nuclear microprobe. The production of mixed beams in an electrostatically focussed micro- probe have already been demonstrated. This paper will show how mixed beams can be produced on a single-ended accelerator. Indications of how to produce them on a tandem will also be given. Applications of these mixed beams in micro-lithography, scanning transmission ion microscopy (STIM) imaging and ion beam induced charge (IBIC) imaging will also be presented. 3 refs., 3 figs.

  16. Development of a nuclear microprobe at IGCAR

    International Nuclear Information System (INIS)

    Ramesh, C.; Nair, K.G.M.; Thampi, N.S.; Saha, B.; Mathews, C.K.

    1988-01-01

    A nuclear microprobe is being developed at IGCAR. The system is being built to determine the profiles of light elements, specially carbon in clad and other structural materials of a fast breeder reactor. By scanning a focussed charged particle beam on the sample surface and by detecting the charged particle induced emissions, an elemental map of the surface is obtained. The paper gives the basic design considerations and present status. (author)

  17. The nuclear microprobe of the CENBG: the choices

    International Nuclear Information System (INIS)

    Llabador, Y.

    1987-04-01

    A microbeam line with a spatial resolution of the micrometer order has been set on the Van de Graaf of the Bordeaux-Gradignan nuclear center. This report presents the different stages of the microprobe design: the experimental device which has been chosen, the reason of the different choices, the traps to keep out of during the construction (for instance, the accuracy of the mechanical standards) [fr

  18. Environmental applications of the LANL nuclear microprobe

    International Nuclear Information System (INIS)

    Hickmott, D.D.; Herrin, J.M.; Abell, R.; George, M.; Gauerke, E.R.; Denniston, R.F.

    1997-01-01

    The LANL nuclear microprobe has been used to study the distributions of trace elements (TE) of environmental interest including: (1) metals in coal and fly ash, (2) Pb in the Bandelier Tuff (BT), (3) Ba in tree rings, (4) Mn, Fe, Sr and Y in Yucca Mountain calcites. Micro-PIXE (MP) analyses with 5-10 micrometer spatial resolution provide constraints on processes that redistribute contaminants in the environment, and hence may help answer environmental problems where fine-scale chemical records are important. MP analyses of particulates in coal and ash show that pyrite contains As, Se, Hg and Pb; macerals contain Cr, halogens and S; cenospheres contain As, Se and Ni; and hematite ash contains Ni and As. Understanding these elemental modes of occurrence allows prediction of metal behavior in boilers and may enhance compliance with the Clean Air Act Amendments. Fine-grained high-Pb minerals were identified using SEM and MP analyses of BT minerals. These minerals were from samples associated with deep-groundwater wells containing Pb at levels greater than regulatory limits. Pb is concentrated in Pb minerals (e.g. cerussite), smectite, and hematite formed during low-T alteration of tuff. Understanding mineralogic speciation of metals may provide insights into sources of groundwater pollution. Tree rings from ponderosa pines that grew in a Ba-contaminated drainage were analyzed using MP. Ba concentrations are typically higher in rings that formed after operations discharging Ba to the environment began. Such tree-ring analyses may ultimately provide information on rates of contaminant migration in the environment. TE in zoned calcites from Yucca Mountain were analyzed by MP. Calcites from the saturated zone (SZ) have distinct chemical signatures (high Fe, Mn and low Y). No calcites in the unsaturated zone with SZ chemical signatures were found using MP

  19. Quantitative microanalysis with a nuclear microprobe

    International Nuclear Information System (INIS)

    Themner, Klas.

    1989-01-01

    The analytical techniques of paticle induced X-ray emission (PIXE) and Rutherford backscattering (RBS), together with the nuclear microprobe, form a very powerful tool for performing quantitative microanalysis of biological material. Calibration of the X-ray detection system in the microprobe set-up has been performed and the accuracy of the quantitative procedure using RBS for determination of the areal mass density was investigated. The accuracy of the analysis can be affected by alteration in the elemental concentrations during irradiation due to the radiation damage induced by the very intense beams of ionixing radiation. Loss of matrix elements from freeze-dried tissue sections and polymer films have been studied during proton and photon irradiation and the effect on the accuracy discussed. Scanning the beam over an area of the target, with e.g. 32x32 pixels, in order to produce en elemental map, yields a lot of information and, to be able to make an accurate quantitatification, a fast algorithm using descriptions of the different spectral contributions is of need. The production of continuum X-rays by 2.55 MeV protons has been studied and absolute cross-sections for the bremsstrahlung production from thin carbon and some polymer films determined. For the determination of the bremsstrahlung background knowledge of the amounts of the matrix elements is important and a fast program for the evaluation of spectra of proton back- and forward scattering from biological samples has been developed. Quantitative microanalysis with the nuclear microprobe has been performed on brain tissue from rats subjected to different pathological conditions. Increase in calcium levels and decrease in potssium levels for animals subjected to crebral ischaemia and for animals suffering from epileptic seizures were observed coincidentally with or, in some cases before, visible signs of cell necrosis. (author)

  20. The new scanning nuclear microprobe in Uppsala

    International Nuclear Information System (INIS)

    Sunde, T.; Nystroem, J.; Lindh, U.

    1991-01-01

    During 1989/90 a scanning microprobe, developed for 2-4 MeV protons and submicron resolution, is being installed at the EN-tandem accelerator at the The Svedberg Laboratory, Uppsala University, Sweden. The probe-forming units (object diaphragm, aperture diaphragm and triplet of spark-eroded quadrupoles), the scanning unit of current-controlled ferrite cores and a current digitizer are of Oxford design. The other parts are commercial products or are constructed by ourselves. The latter includes the equipment for optical alignment by interference, a feedback-controlled magnetic beam steerer and stabiliser, a fast beam deflector, specially designed mechanical vibration reducers and dedicated AT expansion cards for scanning control and data acquisition. (orig.)

  1. High resolution, high sensitivity imaging and analysis of minerals and inclusions (fluid and melt) using the new CSIRO-GEMOC nuclear microprobe

    International Nuclear Information System (INIS)

    Ryan, C.G.; McInnes, B.M.; Van Achterbergh, E.; Williams, P.J.; Dong, G.; Zaw, K.

    1999-01-01

    Full text: The new CSIRO-GEMOC Nuclear Microprobe (NMP) The instrument was designed specifically for minerals analysis and imaging and to achieve ppm to sub-ppm sensitivity at a spatial resolution of 1-2 μm using X-rays and y-rays induced by MeV energy ion beams. The key feature of the design is a unique magnetic quadrupole quintuplet ion focussing system that combines high current with high spatial resolution (Ryan et al., 1999). These design goals have been achieved or exceeded. On the first day of operation, a spot-size of 1.3 μm was obtained at a beam current of 0.5 nA, suitable for fluid inclusion analysis and imaging. The spot-size grows to just 1.8 μm at 10 nA (3 MeV protons), ideal for mineralogical samples with detection limits down to 0.2 ppm achieved in quantitative, high resolution, trace element images. Applications of the NMP include: research into ore deposit processes through trace element geochemistry, mineralogy and fluid inclusion analysis of ancient deposits and active sea-floor environments, ore characterization, and fundamental studies of mantle processes and extraterrestrial material. Quantitative True Elemental Imaging Dynamic Analysis is a method for projecting quantitative major and trace element images from proton-induced X-ray emission (PIXE) data obtained using the NMP (Ryan et al., 1995). The method un-mixes full elemental spectral signatures to produce quantitative images that can be directly interrogated for the concentrations of all elements in selected areas or line projections, etc. Fluid Inclusion Analysis and Imaging The analysis of fluids trapped as fluid inclusions in minerals holds the key to understanding ore metal pathways and ore formation processes. PIXE analysis using the NMP provides a direct non-destructive method to determine the composition of these trapped fluids with detection limits down to 20 ppm. However, some PIXE results have been controversial, such as the strong partitioning of Cu into the vapour phase (e

  2. High resolution techniques using scanning proton microprobe (SPM)

    International Nuclear Information System (INIS)

    Cholewa, M.; Saint, A.; Prawer, S.; Laird, J.S.; Legge, G.J.F.; Bardos, R.A.; Moorhead, G.F.; Taylor, G.N.; Stuart, S.A.; Howard, J.

    1994-01-01

    The very high resolution (down to 50 nm) achieved with low beam currents (fA) in a scanning ion microprobe have lead to many nondestructive techniques of microanalysis. This paper discusses recent developments and applications in the use of 3-D STIM (scanning transmission ion microscopy) Tomography, channeling STIM and IBIC (ion beam induced charge). (orig.)

  3. The Fudan nuclear microprobe set-up and performance

    International Nuclear Information System (INIS)

    Zhong, L.; Zhuang, W.; Shen, H.; Mi, Y.; Wu, Y.; Liu, B.; Yang, M.; Cheng, H.

    2007-01-01

    A new scanning nuclear microprobe has been constructed at the Institute of Modern Physics in Fudan University, to replace the old microbeam system which had been running for more than ten years. The key parts were purchased from Oxford Microbeams Ltd., including triplet quadrupole lens (model OM-150), collimator slits, scanning system, target chamber, and data acquisition system. Ion beams are provided from a NEC 9SDH-2 Tandem accelerator. Three CCD cameras and multiple monitors were installed to assist beam adjust. The design of beam line and beam monitors is described. Beam optics calculations were carried out based on the specific Fudan microprobe system geometry, and the results regarding beam line performance and limitations of the spacial resolution are presented and discussed here. A comparison with experimental results is given as well. About 1.5 μm beam spot size could be achieved with a 3 MeV proton beam at a current of around 10 pA. Recently, the new microprobe is applied to obtain information of fly ash particle, algae cell and otoliths

  4. The INS nuclear microprobe and its application

    International Nuclear Information System (INIS)

    Coote, G.E.

    1986-01-01

    The nuclear microprobe directs a well-focused beam of high-energy protons or deuterons at a solid specimen inside a vacuum chamber. Atomic and nuclear reactions are induced in those elements in a layer about 20 micro m thick, leading to the emission of characteristic x-rays, gamma rays, and charged particles as well as Rutherford scattering of the incident beam. These radiations impinge on several detectors near the specimen (NaI, Ge(Li), Si(Li) and Si surface barrier). Using proton-excited x-rays all elements above Na may be detected with sensitivities 10 or 100 times that of the electron probe, while elements which can be estimated from their gamma rays include C, N, O, F, Na and Al. In most of our projects the distribution of a trace or minor element (e.g. F, N) is compared to that of a major element (e.g. Ca or Fe). Recent areas of application include archaeometry (diffusion profiles of F in bones and teeth; depth profiles of sodium in obsidian), geology (F concentrations in mineral grains; studies of the Cretaceous-Tertiary boundary), metallurgy (C, O, N in steel and in welds; S, O, C in corrosion layers), fisheries management (Zn, Sr in otoliths; F in dogfish fin spines and vertebrae), biology (Fe, Sr, N in egg shells; trace elements in human hair), and dental research

  5. Applications of nuclear microprobes in the semiconductor industry

    International Nuclear Information System (INIS)

    Takai, M.

    1996-01-01

    Possible nuclear microprobe applications in semiconductor industries are discussed. A unique technique using soft-error mapping and ion beam induced current measurements for reliability testing of dynamic random access memories such as soft-error immunity and noise carrier suppression has been developed for obtaining design parameters of future memory devices. Nano-probes and small installation areas are required for the use of microprobes in the semiconductor industry. Issues arising from microprobe applications such as damage induced by the probe beam are clarified. (orig.)

  6. Multidimensional elemental analysis with the Sandia nuclear microprobe

    International Nuclear Information System (INIS)

    Doyle, B.L.

    1988-01-01

    It is well known that many of the ion beam analysis techniques such as Rutherford backscattering spectrometry, elastic recoil detection, resonant and nonresonant nuclear reaction analysis can be used to nondestructively obtain concentration depth profiles of elements in solids. When these techniques are combined with the small beam spot capabilities of a scanned nuclear microprobe, sample composition can be determined in up to three dimensions. This paper will review the various procedures used to collect and analyze multidimensional data using the Sandia nuclear microprobe. In addition, examples of how these data are being used in the study of materials will be shown. (author)

  7. The CEA nuclear microprobe. Description, possibilities, application examples

    International Nuclear Information System (INIS)

    Engelmann, C.; Bardy, J.

    1986-05-01

    The nuclear microprobe installed on one of the beam lines of a 4 MV Van de Graaff located in the Research Center of Bruyeres-le-Chatel is described. The various possibilities, particularly the imaging system, and the performances of the instrument are exposed. Two typical application examples concerning, the first, the determination of the deuterium and tritium in glass microballons, the second, the detection and the localization of carbon and oxygen in the superficial layer of lithium hydride pellets, are given. Preliminary results of some other application examples are also presented. The advantages of the nuclear microprobe over the other ponctual analysis techniques are emphasized. 7 refs, 19 figs [fr

  8. The remote control of nuclear microprobes over the Internet

    International Nuclear Information System (INIS)

    Churms, C.L.; Prozesky, V.M.; Springhorn, K.A.

    1999-01-01

    Whereas the concept of remote control is not new, the required equipment and data link have typically been costly and specialized. With the growing availability of reliable Internet connection, it has however become possible and increasingly attractive to be able to control complex equipment remotely over the Internet. Some methods of Internet Remote control are discussed, bearing in mind the specific needs of nuclear microprobe control. One such system has been implemented at the NAC nuclear microprobe, and even though improvements are envisaged, it is already functioning satisfactorily

  9. Developments of new generation nuclear microprobe systems at the University of Melbourne

    International Nuclear Information System (INIS)

    Rout, B.; Jamieson, D.N.; Hopt, R.; Hearne, S.; Szymaski, R.

    2002-01-01

    Full text: A review of the recent developments in fabricating a new generation nuclear microprobe systems at University of Melbourne, Melbourne, will be presented. These new generation systems present high spatial resolution (less than 1 micrometer) with increasing current density (in excess of 100 pA/micrometer 2 ) of the probing ion beam. Detectors with large solid angles and high brightness of the ion source of the accelerator increase the capabilities of these microprobes many fold. Some of the key ingredients of these microprobes are (i) novel magnetic quadrupole lens quintuplet probe forming system (ii) integrated fast data acquisition system to handle high count rates (excess of 100 KHz) due to increasing current density as well as large detector solid angles up to 4 detector stations. Full dead time corrected and charge normalised maps are also implemented to counter the problems normally associated with such high count rate systems. First version of these systems is presently under operation at CSIRO, Sydney. Another similar system is currently being installed at Dutch Institute for Nuclear and High Energy Physics, Amsterdam, Netherlands. A further optimised version of the CSIRO/MARC quintuplet probe forming systems is currently being fabricated at University of Melbourne. Some of the applications involve microelectronic materials, superconductors and geological samples. We will be presenting exciting results arising out of investigations into these materials. We will be demonstrating ultimate spatial resolution of the new microprobe being fabricated at Melbourne

  10. Characterization of semiconductor and frontier materials by nuclear microprobe technology

    International Nuclear Information System (INIS)

    Zhu Jieqing; Li Xiaolin; Yang Changyi; Lu Rongrong; Wang Jiqing; Guo Panlin

    2002-01-01

    The nuclear microprobe technology is used to characterize the properties of semiconductor and other frontier materials at the stages of their synthesis, modification, integration and application. On the basis of the beam current being used, the analytical nuclear microprobe techniques being used in this project can be divided into two categories: high beam current (PIXE, RBS, PEB) or low beam current (IBIC, STIM) techniques. The material properties measured are the thickness and composition of a composite surface on a SiC ceramic, the sputtering-induced surface segregation and depth profile change in a Ag-Cu binary alloy, the irradiation effects on the CCE of CVD diamond, the CCE profile at a polycrystalline CVD diamond film and a GaAs diode at different voltage biases and finally, the characterization of individual sample on an integrated material chip. (author)

  11. Development of a nuclear microprobe and its application to neurobiology

    International Nuclear Information System (INIS)

    Tapper, Staffan.

    1989-01-01

    A nuclear microprobe has been developed at the Pelletron accelerator in Lund. The design of the achromatic beam focusing system as well as of the beam scanning system is described. The focusing system consists of three magnetic- and three electrostatic quadrupole lenses together forming an chromatic quadrupole triplet with symmetric focusing properties. The beam quality from the accelerator has been improved by use of ultrathin stripper foils. The nuclear microprobe set-up has been applied to investigation of brain tissue specimens. The elemantal disorder following epileptic seizures has been studied by micro-PIXE analysis. A combination of macro- and micro-PIXE analysis have been utilized in an investigaiton of elemental differences between normal human brain and human brain tumours. In the context of the quantification procedure in micro-PIXE analysis, callibration and X-ray detector response function are discussed. (author)

  12. Operation and acquisition automation of a nuclear microprobe

    International Nuclear Information System (INIS)

    Simond, Isabelle

    1990-01-01

    The purpose of this work was to design the hardware and the software parts of data acquisition and its graphical analyses of a nuclear microprobe. Our realisation was built from a microprocessor 68020 and specialized co-processors on a VME bus. The more important demand was the amount of time required to collect the data and to perform the graphical analyses during the acquisition. To overcome this problem, we adapted a real time operating system and its kernel to our need, and built special graphical processes. (author) [fr

  13. Stained glasses under the nuclear microprobe: A window into history

    Energy Technology Data Exchange (ETDEWEB)

    Vilarigues, M. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal)], E-mail: mgv@fct.unl.pt; Fernandes, P. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2009-06-15

    Stained glass fragments from the 15th, 16th and 20th centuries, belonging to Mosteiro de Santa Maria da Vitoria, Batalha (Portugal), were characterised non-destructively in a nuclear microprobe. The work aimed at finding the composition of the glasses and glass paintings and relating these with the corresponding production periods. The elemental compositions of the glass fragments were obtained by means of scanning micro-beam Particle Induced X-ray Emission ({mu}-PIXE) spectrometry in selected cross-sections. These were complemented by micro X-Ray fluorescence spectrometry. Characterisation of colour was performed by optical absorption spectroscopy in the UV-vis range, while the corrosion products were identified by optical microscopy and {mu}-FTIR (Fourier Transform Infra Red) spectroscopy in combination with the data generated by {mu}-PIXE. Nuclear microprobe analysis allowed unveiling the compositions and structures, in particular of glass paintings and corrosion products. While it is not surprising that Fe, Cu and Pb were the main elements identified in the grisaille paintings of all studied periods, as well as Ag and Cu found in the glasses decorated with yellow silver painting, their distribution gave important clues on the materials and techniques used to manufacture these stained glasses. Furthermore, it allowed establishing a definite relation between the compositions found and the periods of production, with the added bonus of correctly reassigning the manufacturing period of some samples.

  14. The new confocal heavy ion microprobe beamline at ANSTO: The first microprobe resolution tests and applications for elemental imaging and analysis

    Science.gov (United States)

    Pastuovic, Z.; Siegele, R.; Cohen, D. D.; Mann, M.; Ionescu, M.; Button, D.; Long, S.

    2017-08-01

    The Centre for Accelerator Science facility at ANSTO has been expanded with the new NEC 6 MV ;SIRIUS; accelerator system in 2015. In this paper we present a detailed description of the new nuclear microprobe-Confocal Heavy Ion Micro-Probe (CHIMP) together with results of the microprobe resolution testing and the elemental analysis performed on typical samples of mineral ore deposits and hyper-accumulating plants regularly measured at ANSTO. The CHIMP focusing and scanning systems are based on the OM-150 Oxford quadrupole triplet and the OM-26 separated scan-coil doublet configurations. A maximum ion rigidity of 38.9 amu-MeV was determined for the following nuclear microprobe configuration: the distance from object aperture to collimating slits of 5890 mm, the working distance of 165 mm and the lens bore diameter of 11 mm. The overall distance from the object to the image plane is 7138 mm. The CHIMP beamline has been tested with the 3 MeV H+ and 6 MeV He2+ ion beams. The settings of the object and collimating apertures have been optimized using the WinTRAX simulation code for calculation of the optimum acceptance settings in order to obtain the highest possible ion current for beam spot sizes of 1 μm and 5 μm. For optimized aperture settings of the CHIMP the beam brightness was measured to be ∼0.9 pA μm-2 mrad-2 for 3 MeV H+ ions, while the brightness of ∼0.4 pA μm-2 mrad-2 was measured for 6 MeV He2+ ions. The smallest beam sizes were achieved using a microbeam with reduced particle rate of 1000 Hz passing through the object slit apertures several micrometers wide. Under these conditions a spatial resolution of ∼0.6 μm × 1.5 μm for 3 MeV H+ and ∼1.8 μm × 1.8 μm for 6 MeV He2+ microbeams in horizontal (and vertical) dimension has been achieved. The beam sizes were verified using STIM imaging on 2000 and 1000 mesh Cu electron microscope grids.

  15. Round robin: Quantitative lateral resolution of PHI XPS microprobes Quantum 2000/Quantera SXM

    International Nuclear Information System (INIS)

    Scheithauer, Uwe; Kolb, Max; Kip, Gerard A.M.; Naburgh, Emile; Snijders, J.H.M.

    2016-01-01

    Highlights: • The quantitative lateral resolution of 7 PHI XPS microprobes has been estimated in a round robin. • An ellipsoidally shaped quartz crystal monochromatizes the Alkα radiation and refocuses it from the Al anode to the sample surface. • The long tail contributions of the X-ray beam intensity distribution were measured using a new and innovative approach. • This quantitative lateral resolution has a significantly larger value than the nominal X-ray beam diameter. • The quantitative lateral resolution follows a trend in time: The newer the monochromator so much the better the quantitative lateral resolution. - Abstract: The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitative lateral resolution of 7 PHI XPS microprobes has been estimated. As expected, the quantitative lateral resolution has significantly larger values than the nominal X-ray beam diameter. The estimated values of the quantitative lateral resolution follow a trend in time: the newer the monochromator of an XPS microprobe so much the better the quantitative lateral resolution.

  16. Round robin: Quantitative lateral resolution of PHI XPS microprobes Quantum 2000/Quantera SXM

    Energy Technology Data Exchange (ETDEWEB)

    Scheithauer, Uwe, E-mail: scht.uhg@googlemail.com [82008 Unterhaching (Germany); Kolb, Max, E-mail: max.kolb@airbus.com [Airbus Group Innovations, TX2, 81663 Munich (Germany); Kip, Gerard A.M., E-mail: G.A.M.Kip@utwente.nl [Universiteit Twente, MESA+ Nanolab, Postbus 217, 7500AE Enschede (Netherlands); Naburgh, Emile, E-mail: e.p.naburgh@philips.com [Materials Analysis, Philips Innovation Services, High Tech Campus 11, 5656 AE Eindhoven (Netherlands); Snijders, J.H.M., E-mail: j.h.m.snijders@philips.com [Materials Analysis, Philips Innovation Services, High Tech Campus 11, 5656 AE Eindhoven (Netherlands)

    2016-07-15

    Highlights: • The quantitative lateral resolution of 7 PHI XPS microprobes has been estimated in a round robin. • An ellipsoidally shaped quartz crystal monochromatizes the Alkα radiation and refocuses it from the Al anode to the sample surface. • The long tail contributions of the X-ray beam intensity distribution were measured using a new and innovative approach. • This quantitative lateral resolution has a significantly larger value than the nominal X-ray beam diameter. • The quantitative lateral resolution follows a trend in time: The newer the monochromator so much the better the quantitative lateral resolution. - Abstract: The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitative lateral resolution of 7 PHI XPS microprobes has been estimated. As expected, the quantitative lateral resolution has significantly larger values than the nominal X-ray beam diameter. The estimated values of the quantitative lateral resolution follow a trend in time: the newer the monochromator of an XPS microprobe so much the better the quantitative lateral resolution.

  17. A new Krakow scanning nuclear microprobe performance tests and early application experienc

    CERN Document Server

    Lebed, S; Polak, W; Potempa, A W; Stachura, Z; Paszkowski, M

    2001-01-01

    A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed,installed and tested at the 3MV Van de Graaff accelerator in Krakow.The MP resolution of 3.3 mu m was reached for 2.4 MeV proton beam in the high-current mode (>= 100pA).The MP facility provides a local,non-destructive,quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique.As example of possible application an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented.

  18. Nuclear microprobe imaging of gallium nitrate in cancer cells

    Science.gov (United States)

    Ortega, Richard; Suda, Asami; Devès, Guillaume

    2003-09-01

    Gallium nitrate is used in clinical oncology as treatment for hypercalcemia and for cancer that has spread to the bone. Its mechanism of antitumor action has not been fully elucidated yet. The knowledge of the intracellular distribution of anticancer drugs is of particular interest in oncology to better understand their cellular pharmacology. In addition, most metal-based anticancer compounds interact with endogenous trace elements in cells, altering their metabolism. The purpose of this experiment was to examine, by use of nuclear microprobe analysis, the cellular distribution of gallium and endogenous trace elements within cancer cells exposed to gallium nitrate. In a majority of cellular analyses, gallium was found homogeneously distributed in cells following the distribution of carbon. In a smaller number of cells, however, gallium appeared concentrated together with P, Ca and Fe within round structures of about 2-5 μm diameter located in the perinuclear region. These intracellular structures are typical of lysosomial material.

  19. Nuclear microprobe imaging of gallium nitrate in cancer cells

    International Nuclear Information System (INIS)

    Ortega, Richard; Suda, Asami; Deves, Guillaume

    2003-01-01

    Gallium nitrate is used in clinical oncology as treatment for hypercalcemia and for cancer that has spread to the bone. Its mechanism of antitumor action has not been fully elucidated yet. The knowledge of the intracellular distribution of anticancer drugs is of particular interest in oncology to better understand their cellular pharmacology. In addition, most metal-based anticancer compounds interact with endogenous trace elements in cells, altering their metabolism. The purpose of this experiment was to examine, by use of nuclear microprobe analysis, the cellular distribution of gallium and endogenous trace elements within cancer cells exposed to gallium nitrate. In a majority of cellular analyses, gallium was found homogeneously distributed in cells following the distribution of carbon. In a smaller number of cells, however, gallium appeared concentrated together with P, Ca and Fe within round structures of about 2-5 μm diameter located in the perinuclear region. These intracellular structures are typical of lysosomial material

  20. Analysis of biological materials using a nuclear microprobe

    Science.gov (United States)

    Mulware, Stephen Juma

    The use of nuclear microprobe techniques including: Particle induced x-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS) for elemental analysis and quantitative elemental imaging of biological samples is especially useful in biological and biomedical research because of its high sensitivity for physiologically important trace elements or toxic heavy metals. The nuclear microprobe of the Ion Beam Modification and Analysis Laboratory (IBMAL) has been used to study the enhancement in metal uptake of two different plants. The roots of corn (Zea mays) have been analyzed to study the enhancement of iron uptake by adding Fe (II) or Fe(III) of different concentrations to the germinating medium of the seeds. The Fe uptake enhancement effect produced by lacing the germinating medium with carbon nanotubes has also been investigated. The aim of this investigation is to ensure not only high crop yield but also Fe-rich food products especially from calcareous soil which covers 30% of world's agricultural land. The result will help reduce iron deficiency anemia, which has been identified as the leading nutritional disorder especially in developing countries by the World Health Organization. For the second plant, Mexican marigold (Tagetes erecta ), the effect of an arbuscular mycorrhizal fungi (Glomus intraradices ) for the improvement of lead phytoremediation of lead contaminated soil has been investigated. Phytoremediation provides an environmentally safe technique of removing toxic heavy metals (like lead), which can find their way into human food, from lands contaminated by human activities like mining or by natural disasters like earthquakes. The roots of Mexican marigold have been analyzed to study the role of arbuscular mycorrhizal fungi in enhancement of lead uptake from the contaminated rhizosphere.

  1. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Doubleday, Zoe [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)], E-mail: zoeanned@utas.edu.au; Belton, David [CSIRO Exploration and Mining, University of Melbourne (School of Physics), Melbourne 3010 (Australia); Pecl, Gretta; Semmens, Jayson [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)

    2008-01-15

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure.

  2. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    International Nuclear Information System (INIS)

    Doubleday, Zoe; Belton, David; Pecl, Gretta; Semmens, Jayson

    2008-01-01

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure

  3. Nuclear microprobe analysis of lead profile in crocodile bones

    Energy Technology Data Exchange (ETDEWEB)

    Orlic, I. E-mail: ivo@ansto.gov.au; Siegele, R.; Hammerton, K.; Jeffree, R.A.; Cohen, D.D

    2003-09-01

    Elevated concentrations of lead were found in Australian free ranging saltwater crocodile (Crocodylus porosus) bone and flesh. Lead shots were found as potential source of lead in these animals. ANSTO's heavy ion nuclear microprobe was used to measure the distribution of Pb in a number of bones and osteoderms. The aim was to find out if elevated Pb concentration remains in growth rings and if the concentration is correlated with the blood levels recorded at the time. Results of our study show a very distinct distribution of accumulated Pb in bones and osteoderms as well as good correlation with the level of lead concentration in blood. To investigate influence of ion species on detection limits measurements of the same sample were performed by using 3 MeV protons, 9 MeV He ions and 20 MeV carbon ions. Peak to background ratios, detection limits and the overall 'quality' of obtained spectra are compared and discussed.

  4. Nuclear micro-probe analysis of Arabidopsis thaliana leaves

    International Nuclear Information System (INIS)

    Ager, F.J.; Ynsa, M.D.; Dominguez-Solis, J.R.; Lopez-Martin, M.C.; Gotor, C.; Romero, L.C.

    2003-01-01

    Phytoremediation is a cost-effective plant-based approach for remediation of soils and waters which takes advantage of the remarkable ability of some plants to concentrate elements and compounds from the environment and to metabolize various molecules in their tissues, such as toxic heavy metals and organic pollutants. Nowadays, phytoremediation technology is becoming of paramount importance when environmental decontamination is concerned, due to the emerging knowledge of its physiological and molecular mechanisms and the new biological and engineering strategies designed to optimize and improve it. In addition, the feasibility of using plants for environmental cleanup has been confirmed by many different trials around the world. Arabidopsis thaliana plants can be used for basic studies to improve the technology on phytoremediation. Making use of nuclear microscopy techniques, in this paper we study leaves of wild type and transgenic A. thaliana plants grown in a cadmium-rich environment under different conditions. Micro-PIXE, RBS and SEM analyses, performed on the scanning proton micro-probe at the CNA in Seville (Spain), prove that cadmium is preferentially sequestered in the central region of epidermal trichome and allow comparing the effects of genetic modifications

  5. Structural and electrical characterisation of semiconductor materials using a nuclear microprobe

    International Nuclear Information System (INIS)

    Jamieson, D.N.

    1998-01-01

    The domain of high-resolution imaging techniques (sub-micron) traditionally belongs to low-energy ion beams (ke V ion microprobe), electrons (transmission or scanning electron microscopy), light (near field microscopy), or all variants of scanning probe microscopies. Now, nuclear techniques of analysis, with a nuclear microprobe, have entered this domain, bringing a range of unique techniques for making images. In addition to-conventional techniques like Rutherford (and non-Rutherford) backscattering spectrometry and particle induced x-ray emission for structural characterisation, new ion beam analysis techniques have been developed for electrical characterisation as well. Foremost of these new techniques is ion beam induced charge (IBIC) which has seen an explosion of applications in the last five years to the study of charge transport properties of a variety of materials including polycrystalline diamond and silicon. An additional novel technique is ionoluminescence, which may be used to image various electronic properties of the material. Presented here are some examples of these imaging techniques in a variety of semiconductor materials. In all these examples, the specimens display structural inhomogeneities on the scale of 10 micrometres, making it essential to employ a focused beam. (author)

  6. Structural and electrical characterisation of semiconductor materials using a nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics, Microanalytical Centre

    1998-06-01

    The domain of high-resolution imaging techniques (sub-micron) traditionally belongs to low-energy ion beams (ke V ion microprobe), electrons (transmission or scanning electron microscopy), light (near field microscopy), or all variants of scanning probe microscopies. Now, nuclear techniques of analysis, with a nuclear microprobe, have entered this domain, bringing a range of unique techniques for making images. In addition to-conventional techniques like Rutherford (and non-Rutherford) backscattering spectrometry and particle induced x-ray emission for structural characterisation, new ion beam analysis techniques have been developed for electrical characterisation as well. Foremost of these new techniques is ion beam induced charge (IBIC) which has seen an explosion of applications in the last five years to the study of charge transport properties of a variety of materials including polycrystalline diamond and silicon. An additional novel technique is ionoluminescence, which may be used to image various electronic properties of the material. Presented here are some examples of these imaging techniques in a variety of semiconductor materials. In all these examples, the specimens display structural inhomogeneities on the scale of 10 micrometres, making it essential to employ a focused beam. (author). Extended abstract. 18 refs. 4 figs.

  7. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    International Nuclear Information System (INIS)

    Nesprías, F.; Debray, M.E.; Davidson, J.; Kreiner, A.J.

    2013-01-01

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift 35 Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO 3 , a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well

  8. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    Energy Technology Data Exchange (ETDEWEB)

    Nesprías, F. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Debray, M.E., E-mail: debray@tandar.cnea.gov.ar [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); Davidson, J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); Kreiner, A.J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); and others

    2013-04-01

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift {sup 35}Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO{sub 3}, a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well.

  9. Progress of the new CSIRO-GEMOC nuclear microprobe: first results, performance and recent applications

    International Nuclear Information System (INIS)

    Ryan, C.G.; Cripps, G.; Sie, S.H.; Suter, G.F.; Jamieson, D.N.; Griffin, W.L.; Commonwealth Scientific and Industrial Research Organisation

    1999-01-01

    The new CSIRO-GEMOC Nuclear Microprobe (NMP) features a number of technical advances for high resolution, high sensitivity microanalysis. It was designed at the CSIRO and developed as collaboration between the CSlRO, the GEMOC key-centre at Macquarie University and the MARC group of the University of Melbourne. For imaging applications, it also features a software system using a powerful algorithm called Dynamic Analysis, developed at the CSIRO for unmixing elemental signatures in proton induced X-ray emission (PIXE) data, to provide a tool for rapid quantitative imaging of trace and major element spatial distribution in minerals. This paper reports on the performance of the NMP and examples of its application over the past 6 months since completion

  10. Early works on the nuclear microprobe for microelectronics irradiation tests at the CEICI (Sevilla, Spain)

    International Nuclear Information System (INIS)

    Palomo, F.R.; Morilla, Y.; Mogollon, J.M.; Garcia-Lopez, J.; Labrador, J.A.; Aguirre, M.A.

    2011-01-01

    Particle radiation effects are a fundamental problem in the use of numerous electronic devices for space applications, which is aggravated with the technology shrinking towards smaller and smaller scales. The suitability of low-energy accelerators for irradiation testing is being considered nowadays. Moreover, the possibility to use a nuclear microprobe, with a lateral resolution of a few microns, allows us to evaluate the behavior under ion irradiation of specific elements in an electronic device. The CEICI is the new CEnter for Integrated Circuits Irradiation tests, created into the facilities at the Centro Nacional de Aceleradores (CNA) in Sevilla-Spain. We have verified that our 3 MV Tandem accelerator, typically used for ion beam characterization of materials, is also a valuable tool to perform irradiation experiments in the low LET (Linear Energy Transfer) region.

  11. The French AEC nuclear microprobe: description and first application examples

    International Nuclear Information System (INIS)

    Engelmann, C.; Bardy, J.

    1983-05-01

    The major components of the microprobe are briefly described. The performances and the varying possibilities authorized by the instrument are given. Some application examples concerning especially the determination of concentration profiles in an aqueous leached glass and the distribution of deuterium in a graphite sample exposed to plasma in a Tokamak device are presented

  12. Elemental composition of paint cross sections by nuclear microprobe analysis

    International Nuclear Information System (INIS)

    Nens, B.; Trocellier, P.; Engelmann, C.; Lahanier, C.

    1982-09-01

    Physico-chemical characterization of pigments used in artistic painting give precious indications on age of paintings and sometimes on geographical origin of ores. After recalling the principle of protons microprobe, first results obtained by microanalysis of painting cross sections for non destructive microanalysis of impurities in white lead are given [fr

  13. The role of nuclear microprobes in the study of technology, provenance and corrosion of cultural heritage: The case of gold and silver items

    International Nuclear Information System (INIS)

    Guerra, M.F.; Tissot, I.

    2013-01-01

    This work gives an overview of the main questions raised by gold and silver items kept in museum collections and of the role of nuclear microprobes in their study and conservation. The different approached questions are illustrated by examples; analytical data is given and discussed; and the advantages of IBA are considered: spatial resolution, penetration depth, limits of detection, mapping, etc

  14. 7th international conference on Nuclear microprobe technology and applications

    International Nuclear Information System (INIS)

    2000-01-01

    This colloquium gives an up-to-date report on the continuously advancing applications and development of microbeam technology. It presents abstracts and oral contributions in the following domains: microprobes facilities, analysis techniques, imaging techniques, micro-ion beam modification of materials, microelectronics, applications in Material Sciences in Biology in Medicine in earth and planetary Sciences in environment in art in archaeology, alternative techniques. (A.L.B.)

  15. A novel ultra-short scanning nuclear microprobe: Design and preliminary results

    International Nuclear Information System (INIS)

    Lebed, S.; Butz, T.; Vogt, J.; Reinert, T.; Spemann, D.; Heitmann, J.; Stachura, Z.; Lekki, J.; Potempa, A.; Styczen, J.; Sulkio-Cleff, B.

    2001-01-01

    The paper describes an optimized scanning nuclear microprobe (MP) with a new ultra-short (total length of 1.85 m) probe forming system based on a divided Russian quadruplet (DRQ) of magnetic quadrupole lenses. Modern electrostatic accelerators have a comparatively high beam brightness of about 10-25 pA/μm 2 /mrad 2 /MeV. This allows the MP proposed to provide a high lateral resolution even with large (1%) parasitic (sextupole and octupole) pole tip field components in all lenses. The features of the design permit the MP operation in the high current and low current modes with a short working distance and inexpensive quadrupole lenses. A new quadrupole doublet design has been developed for the MP. In the present work the calculated features of the new MP are compared with preliminary experimental results obtained with a similar system (total length of 2.3 m) at the INP in Cracow. The new MP is promising for studies of solids or biological samples with high resolutions (0.08-2 μm) in both modes under ambient conditions. A vertical version of the ultra-short MP can be very useful for single ion bombardments of living cells

  16. Depth Probing Soft X-ray Microprobe (DPSXRM) for High Resolution Probing of Earth's Microstructural Samples

    Science.gov (United States)

    Dikedi, P. N.

    2015-12-01

    The Cambrian explosion; occurrence of landslides in very dry weather conditions; rockslides; dead, shriveled-up and crumbled leaves possessing fossil records with the semblance of well preserved, flat leaves; abundance of trilobite tracks in lower and higher rock layers; and sailing stones are enigmas demanding demystifications. These enigmas could be elucidated when data on soil structure, texture and strength are provided by some device with submicrometre accuracy; for these and other reasons, the design of a Depth Probing Soft X-ray Microprobe (DPSXRM), is being proposed; it is expected to deliver soft X-rays, at spatial resolution, ϛ≥600nm and to probe at the depth of 0.5m in 17s. The microprobe is portable compared to a synchrotron radiation facility (Diamond Light Source has land size of 43,300m2); spatial resolution,ϛ , of the DPSXRM surpasses those of the X-ray Fluorescence microanalysis (10µm), electron microprobe (1-3µm) and ion microprobe (5->30µm); the DPSXRM has allowance for multiple targets. Vanadium and Manganese membranes are proposed owing to respective 4.952KeV VKα1 and 5.899KeV MnKα1 X-rays emitted, which best suits micro-probing of Earth's microstructural samples. Compound systems like the Kirk-Patrick and Baez and Wolter optics, aspheric mirrors like elliptical and parabolic optics, small apertures and Abbe sine condition are employed to reduce or remove astigmatism, obliquity, comatic and spherical aberrations—leading to good image quality. Results show that 5.899KeV MnKα1 and 4.952KeV VKα1 soft X-rays will travel a distance of 2.75mm to form circular patches of radii 2.2mm and 2.95mm respectively. Zone plate with nth zone radius of 1.5mm must be positioned 1.5mm and 2mm from the electron gun if circular patches must be formed from 4.952KeV VKα1 and 5.899KeV MnKα1 soft X-rays respectively. The focal lengths of 0.25μm≤ƒ≤1.50μm and 0.04μm≤ƒ≤0.2μm covered by 4.952KeV VKα1 and 5.899KeV Mn Kα1 soft X-Rays, will

  17. Lateral diffusion study of the Pt-Al system using the NAC nuclear microprobe.

    Science.gov (United States)

    de Waal, H.; Pretorius, R.

    1999-10-01

    In this study a nuclear microprobe (NMP) was used to analyse phase formation during reaction in Pt-Al lateral diffusion couples. Phase identification was done by Rutherford backscattering spectroscopy. These results were compared with phase formation during conventional thin film Pt-Al interactions. The co-existence of multiple phases in lateral diffusion couples is discussed with reference to the effective heat of formation (EHF) model.

  18. Lateral diffusion study of the Pt-Al system using the NAC nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Waal, H. de E-mail: dewalla@nac.ac.za; Pretorius, R

    1999-09-02

    In this study a nuclear microprobe (NMP) was used to analyse phase formation during reaction in Pt-Al lateral diffusion couples. Phase identification was done by Rutherford backscattering spectroscopy. These results were compared with phase formation during conventional thin film Pt-Al interactions. The co-existence of multiple phases in lateral diffusion couples is discussed with reference to the effective heat of formation (EHF) model.

  19. Combination of synchrotron radiation X-ray microprobe and nuclear microprobe for chromium and chromium oxidation states quantitative mapping in single cells

    International Nuclear Information System (INIS)

    Ortega, Richard; Deves, Guillaume; Fayard, Barbara; Salome, Murielle; Susini, Jean

    2003-01-01

    Hexavalent chromium compounds are established carcinogens but their mechanism of cell transformation has not been elucidated yet. In this study, chromium oxidation state distribution maps in cells exposed to soluble (Na 2 CrO 4 ), or insoluble (PbCrO 4 ), Cr(VI) compounds have been obtained by use of the ESRF ID-21 X-ray microscope. In addition, the quantitative maps of element distributions in cells have been determined using the nuclear microprobe of Bordeaux-Gradignan. Nuclear microprobe quantitative analysis revealed interesting features on chromium, and lead, cellular uptake. It is suggested that cells can enhance PbCrO 4 solubility, resulting in chromium, but not lead uptake. The differential carcinogenic potential of soluble and insoluble Cr(VI) compounds is discussed with regard to chromium intracellular quantitative distribution

  20. A photomultiplier-based secondary electron imaging system for a nuclear microprobe

    International Nuclear Information System (INIS)

    Alves, L.C.; Breese, M.B.H.; Silva, M.F. da; Soares, J.C.

    2002-01-01

    The ability to define, or recognise particular regions of interest or surface features is vital to the analysis and interpretation of spatially-resolved images collected with a nuclear microprobe. However, good topographic image contrast is difficult to accomplish using PIXE or RBS images due to their inherent insensitivity to topography, lack of elemental variation or poor statistics. Topographic image contrast is commonly obtained in scanning electron microscopy (SEM) by detecting a large flux of secondary electrons produced by the focused keV electron beam. Similar systems have not been widely used on nuclear microprobes due to ion beam intensity fluctuations, which limit the minimum resolvable contrast and present a major limitation for this technique. This paper describes a secondary electron imaging system which has been developed on the Lisbon microprobe. It is based on a scintillator, a photomultiplier operated in a pulsed mode, a pulse shaping electronic chain and ADC, and requires no changes to the existing data acquisition system. Examples of the images obtained from materials such as patterned SiGe wafers and hydrogen-implanted silicon are given, and compared with SEM or optical images

  1. Dedicated accelerator and microprobe line

    International Nuclear Information System (INIS)

    Malmqvist, K.G.; Hylten, G.; Hult, M.; Haakansson, K.; Knox, J.M.; Larsson, N.P.O.; Nilsson, C.; Pallon, J.; Schofield, R.; Swietlicki, E.; Tapper, U.A.S.; Yang Changyi

    1993-01-01

    The development of a dedicated facility for nuclear microprobe analysis and the experiences from using it are discussed. The general properties of the present Lund nuclear microprobe will be described and the advantages of using a dedicated accelerator discussed. (orig.)

  2. Ion beam analysis - development and application of nuclear reaction analysis methods, in particular at a nuclear microprobe

    International Nuclear Information System (INIS)

    Sjoeland, K.A.

    1996-11-01

    This thesis treats the development of Ion Beam Analysis methods, principally for the analysis of light elements at a nuclear microprobe. The light elements in this context are defined as having an atomic number less than approx. 13. The work reported is to a large extent based on multiparameter methods. Several signals are recorded simultaneously, and the data can be effectively analyzed to reveal structures that can not be observed through one-parameter collection. The different techniques are combined in a new set-up at the Lund Nuclear Microprobe. The various detectors for reaction products are arranged in such a way that they can be used for the simultaneous analysis of hydrogen, lithium, boron and fluorine together with traditional PIXE analysis and Scanning Transmission Ion Microscopy as well as photon-tagged Nuclear Reaction Analysis. 48 refs

  3. Nuclear microprobe analysis of the standard reference materials

    International Nuclear Information System (INIS)

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  4. The study of voids in the AuAl thin-film system using the nuclear microprobe

    Science.gov (United States)

    de Waal, H. S.; Pretorius, R.; Prozesky, V. M.; Churms, C. L.

    1997-07-01

    A Nuclear Microprobe (NMP) was used to study void formation in thin film gold-aluminium systems. Microprobe Rutherford Backscattering Spectrometry (μRBS) was utilised to effectively obtain a three-dimensional picture of the void structure on the scale of a few nanometers in the depth dimension and a few microns in the in-plane dimension. This study illustrates the usefulness of the NMP in the study of materials and specifically thin-film structures.

  5. Positron annihilation microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Canter, K F [Brandeis Univ., Waltham, MA (United States)

    1997-03-01

    Advances in positron annihilation microprobe development are reviewed. The present resolution achievable is 3 {mu}m. The ultimate resolution is expected to be 0.1 {mu}m which will enable the positron microprobe to be a valuable tool in the development of 0.1 {mu}m scale electronic devices in the future. (author)

  6. Application of tomographic techniques to two-dimensional surface analysis using the Harwell nuclear microprobe

    International Nuclear Information System (INIS)

    Huddleston, J.; Hutchinson, I.G.; Pierce, T.B.

    1983-01-01

    Nuclear methods of surface analysis are discussed briefly, and the circumstances are described in which a two-dimensional analysis of the sample surface is desirable to enable the surface composition to be mapped accurately. Tomographic techniques of data manipulation are outlined. Data acquisition in the present case is performed by moving the sample in a defined sequence of positions, at each of which analytical data are gathered by the proton microprobe. The method and equipment are outlined. Data processing leading to the reconstruction of the image is summarised. (U.K.)

  7. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    International Nuclear Information System (INIS)

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  8. CMB v. 1.1 Data Acquisition and Evaluation System of the Cracow Nuclear Microprobe

    International Nuclear Information System (INIS)

    Lekki, J.; Hajduk, R.; Potempa, A.; Pieprzyca, T.; Stachura, Z.; Zieblinski, M.; Styczen, J.; Lebed, S.

    2000-11-01

    An overview of the Cracow nuclear microprobe together with its data acquisition and control system is presented. Magnetic deflection was applied for beam scanning, while detector signals acquisition is performed by the NIM/CAMAC modules under supervision of a Windows operating system running on a PC equipped with the GPIB controller card. Total spectra from every detector are accessible on-line during the measurement, while full information about detected energy and beam position is stored to a disk file in the list mode to allow off-line data analysis. System hardware and software setups together with software operations and data formats used for information storing are described. (author)

  9. In situ titanium dioxide nanoparticles quantitative microscopy in cells and in C. elegans using nuclear microprobe analysis

    Energy Technology Data Exchange (ETDEWEB)

    Le Trequesser, Quentin [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, Université de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Saez, Gladys; Devès, Guillaume; Michelet, Claire; Barberet, Philippe [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France); Delville, Marie-Hélène [CNRS, Université de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Seznec, Hervé, E-mail: herve.seznec@cenbg.in2p3.fr [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France)

    2014-12-15

    Detecting and tracking nanomaterials in biological systems is challenging and essential to understand the possible interactions with the living. In this context, in situ analyses were conducted on human skin cells and a multicellular organism (Caenorhabditiselegans) exposed to titanium dioxide nanoparticles (TiO{sub 2} NPs) using nuclear microprobe. Coupled to conventional methods, nuclear microprobe was found to be suitable for accurate description of chemical structure of biological systems and also for detection of native TiO{sub 2} NPs. The method presented herein opens the field to NPs exposure effects analyses and more generally to toxicological analyses assisted by nuclear microprobe. This method will show applications in key research areas where in situ imaging of chemical elements is essential.

  10. Nuclear microprobe studies of elemental distribution in the seagrass Thalassodendron ciliatum

    Energy Technology Data Exchange (ETDEWEB)

    Barnabas, A.D. E-mail: alban@pixie.udw.ac.za; Przybylowicz, W.J.; Mesjasz-Przybylowicz, J.; Pineda, C.A

    1999-09-02

    Elemental levels and distributions in various organs (leaves, upright stems, rhizomes and roots) of the seagrass Thalassodendron ciliatum were determined using the NAC nuclear microprobe. Elemental distributions were obtained using the true elemental imaging system Dynamic Analysis (DA). Cl was the most abundant element present in the organs, occurring in all tissues, but present in relatively low concentrations in epidermal cells of leaves and roots. Na, K, S and Mg were also abundant and occurred in all organ tissues. Ca concentration was highest in the leaves, especially in the epidermis. Low concentrations of P were found and its tissue distribution was limited. Although Fe, Cu, Zn, Mn, Br, Ti and Si were present in relatively small amounts, enrichment of the epidermis with Fe, Ti and Si in all organs, was observed. Fe concentration was the highest in rhizomes while Si concentration was highest in upright stems. The significance of these elemental distribution patterns and the value of the nuclear microprobe in elemental analysis of seagrasses are discussed.

  11. Elemental analysis of single phytoplankton cells using the Lund nuclear microprobe

    International Nuclear Information System (INIS)

    Pallon, Jan; Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Graneli, Edna; Sellborn, Anders; Karlsson, Chatarina

    1999-01-01

    The occurrence of annual marine phytoplankton blooms is becoming a global problem. In Europe, the NUTOX project supported by the EC investigates if unbalanced nutrient compositions in the water promote the dominance of harmful phytoplankton species. One of the tasks is the determination of the elemental composition of single phytoplankton cells. This is carried out using the Lund Nuclear Microprobe with a special focus on C, N, P and K. The overall aim is to understand the mechanism leading to toxin production, model it and eventually propose a counteracting method. The preparative method, used to isolate single living cells while reducing their salt environment, is an important part of the analytical procedure. A comparison of light element detection using backscattering from protons and nuclear reaction analysis using deuterons is made

  12. Ion channelling analysis of pre-amorphised silicon diodes using a nuclear microprobe

    International Nuclear Information System (INIS)

    Thornton, J.; Paus, K.C.

    1988-01-01

    Aligned and random ion channelling analysis was performed on p + n diode structures in silicon, with the Surrey nuclear microprobe. Three different types of diode were investigated, each pre-amorphised by a different ion (Si + , Ge + or Sn + ) before the p + region was formed by BF 2 + implantation. The ion channelling measurements are presented and compared with previously published electrical measurements on these diodes. Relatively large residual disorder and junction leakage currents were found for the Si + pre-amorphised diodes; however, all the diodes were leaky. The results are consistent with dislocation loops within the depletion regions of the diodes causing both the residual disorder and the large leakage currents. Cross-sectional transmission electron microscopy studies support this model. (author)

  13. Elemental characterization of individual glia and glioma cells in the nuclear microprobe

    International Nuclear Information System (INIS)

    Lindh, U.

    1982-01-01

    To investigate whether variations in levels of microelements are reflected at the cellular level, a study of cultured cells was undertaken. For elemental characterization were chosen human glia and glioma cell lines. The cells were freeze-dried and about 1000 cells of each line were analyzed in the nuclear microprobe with a probe diameter of 10 μm. Scanning of the specimens under the beam made possible heat reduction and the X-ray spectrum induced was continuously recorded and subsequently processed in the computer. Elemental maps of the cells were then generated and the information from each member of the cell populations could be considered as well as the population statistics. Mass determination was accomplished by means of the bremsstrahlung continuum intensity. The main feature resulting from the characterization was that the glioma cells in average held appreciably higher contents of copper and zinc than did the glia cells. (orig.)

  14. Experimental investigations into sample preparation of Alzheimer tissue specimens for nuclear microprobe analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, T [CEC-JRC, Central Bureau for Nuclear Measurements, Geel (Belgium); Tapper, U A.S. [Dept. of Nuclear Physics, Lund Inst. of Science and Tech. (Sweden); Sturesson, K; Brun, A [Div. of Neuropathology, Dept. of Pathology, Lund University Hospital (Sweden)

    1991-03-01

    Nuclear microprobe analysis was applied to the study of elemental distribution in brains sections of patients with a diagnosis of Alzheimer's disease. Stained and nonstained cryosections were studied. The work carried out shows that serious elemental losses follow the sample staining procedure. Major losses occurred in a simple rinse of the tissue section, probably reducing most of the in-vivo gradients, which show that generally very little information can be gained from stained sections. However, in many cases stained sections are compulsory because of the requirement to recognize the area which is to be studied. All the elemental maps obtained for the neurofibrillary deposits indicate a localized concentration for Si and probably also Al, associated with the senile plaque core. Neither of these elements were found in the staining solutions used. The validity of the results is discussed as well as the possible link of Al and/or Si in the development of Alzheimer's desease. (orig.).

  15. Nuclear microprobe analysis of muscle biopsies: Applications in pathology and clinic

    International Nuclear Information System (INIS)

    Moretto, Ph.; Coquet, M.; Gherardi, R.K.; Stoedzel, P.

    2000-01-01

    The nuclear microprobe analysis of muscle biopsy sections has been recently applied to investigate different muscle disorders. This technique, employed as a complementary examination in the frame of pathological studies, permitted to confirm the diagnosis for a first pathology and to elucidate the cause of a second. In skeletal muscles of a young patient suffering from a slow progressive myopathy, calcium accumulations have been demonstrated in histologically abnormal fibers. These findings have been compared to histopathological characteristics previously described. On the other hand, we have evaluated muscle sections from two patients who presented symptoms of an inflammatory myopathy, a rare pathology that recently emerged in France. The chemical analyses permitted us to highlight local aluminium infiltration in muscles. The hypothesis of an unusual reaction to intramuscular aluminium accumulation has been advanced. These studies demonstrate the capability for ion beam microanalytical techniques to address acute problems in pathology

  16. Characterization of PE-g-HEMA films prepared by gamma irradiation through nuclear microprobe techniques

    International Nuclear Information System (INIS)

    Ferreira, L.M.; Rodrigues, P.A.; Falcao, A.N.; Leal, J.P.

    2011-01-01

    Complete text of publication follows. The functional success of a copolymer as biomaterial depends fundamentally on their mechanical properties (stemming from the material matrix) and on the characteristics of its surface. For biomedical applications, among all the other important properties, the biocompatibility of the surface acquires extreme importance and can dictate its rejection. One of the issues regarding biocompatibility is cytotoxicity which strongly depends on the contamination level at surface. Ion beam analysis techniques associated to Nuclear Microprobe (PIXE, RBS and STIM) allows a rigorous and precise analysis of the concentration (ppm) and distribution of elements contamination, and may also provide information on its near-surface structure. In this work PE-g-HEMA films with different grafting yields were prepared by mutual gamma irradiation at a 60 Co source and were analyzed through nuclear microprobe. Data collected allowed the qualitative and quantitative evaluation of contaminants distribution observed in the different samples as well as the clarification of some processes occurred during the copolymerization reaction. Qualitative analysis showed a random and no homogeneous distribution of the contaminant elements, independent of the grafting degree, suggesting the existence of several sources of contamination at different stages of their preparation. Results also suggest that this 'phased' contamination occurs simultaneously with mechanisms of agglomeration/entrapment of impurities during the gamma induced copolymerization reaction. Moreover, quantitative data showed that all contaminants found in the copolymeric films are natural contaminants of their reagents of preparation, although at concentrations without toxicological hazard, which points to a low cytotoxic potential. The combined analysis of these data with data from SEM and AFM allowed a better understanding of the surface structure and other properties already observed in these

  17. The mutual diffusion coefficient for (meth)acrylate monomers as determined with a nuclear microprobe

    International Nuclear Information System (INIS)

    Leewis, Christian M.; Mutsaers, Peter H.A.; Jong, Arthur M. de; Ijzendoorn, Leo J. van; Voigt, Martien J.A. de; Ren, Min Q.; Watt, Frank; Broer, Dirk J.

    2004-01-01

    The value of the mutual diffusion coefficient D V of two acrylic monomers is determined with nuclear microprobe measurements on a set of polymer films. These films have been prepared by allowing the monomers to diffuse into each other for a certain time and subsequently applying fast ultraviolet photo-polymerization, which freezes the concentration profile. The monomer diffusion profiles are studied with a scanning 2.1 MeV proton microprobe. Each monomer contains a marker element, e.g., Cl and Si, which are easily detected with proton induced x-ray emission. From the diffusion profiles, it is possible to determine the mutual diffusion coefficient. The mutual diffusion coefficient is dependent of concentration, which is concluded from the asymmetry in the Cl- and Si-profiles. A linear dependence of the mutual diffusion coefficient on the composition is used as a first order approximation. The best fits are obtained for a value of b=(0.38±0.15), which is the ratio of the diffusion coefficient of 1,3-bis(3-methacryloxypropyl)-1, 1,3,3-tetramethyldisiloxane in pure 2-chloroethyl acrylate and the diffusion coefficient of 2-chloroethyl acrylate in pure 1,3-bis(3-methacryloxypropyl)-1,1,3,3-tetramethyldisiloxane. Under the assumption of a linear dependence of the mutual diffusion coefficient D V on monomer composition, it follows that D V =(2.9±0.6)·10 -10 m 2 /s at a 1:1 monomer ratio. With Flory-Huggins expressions for the monomer chemical potentials, one can derive approximate values for the individual monomer diffusion coefficients

  18. Nuclear microprobe analysis of serpentine from the mid-Atlantic ridge

    International Nuclear Information System (INIS)

    Orberger, Beate; Metrich, Nicole; Mosbah, Michelle; Mevel, Catherine; Fouquet, Yves

    1999-01-01

    At mid-ocean ridges, ultramafic rocks are serpentinized by interaction with seawater-derived fluids. Elements, dissolved in large quantities in seawater, e.g., Na, K, Cl, Br, Ca and Sr, can be, in small amounts, incorporated as traces into the crystal structure of the various serpentine minerals (Mg 3 Si 2 O 5 (OH) 4 ). These trace elements can be used to track the composition of the reacting fluids and to constrain physico-chemical conditions. This paper represents the first application of particle-induced X- and γ-ray emission (PIXE/PIGE) analysis to serpentine using the nuclear microprobe at the Laboratoire Pierre Suee (CEA-CNRS). Three types of serpentine, belonging to two different serpentinization generations, have been analysed in samples collected from the Mid-Atlantic Ridge (14 deg. 45'N/45 deg. W) that exposes serpentinized peridotites on which the Logachev black smoker is placed. The trace elements Cl, F, S, Cu, Zn, Ca, K, Ni, Cr and Mn were detected from several tens to several thousands of ppm. Bromine, As and Sr are close to the detection limit of about 5 ppm. The trace element concentrations and interelement relationships in serpentines vary (a) with the serpentine type and (b) with the geographic location to the black smoker. Chlorine and in part S originated from seawater, whereas Cu, Zn, Ca, K, Ni, Cr and Fe and the major amount of S were mobilized from the unaltered host rock and partitioned between the serpentine and the aqueous solution

  19. Nuclear microprobe studies of elemental distributions in dormant seeds of Burkea africana

    Science.gov (United States)

    Witkowski, E. T. F.; Weiersbye-Witkowski, I. M.; Przybyłowicz, W. J.; Mesjasz-Przybyłowicz, J.

    1997-07-01

    Seed nutrient stores are vital post-germination for the establishment of seedlings in harsh and unpredictable environments. Plants of nutrient-poor environments allocate a substantial proportion of total acquired nutrients to reproduction (i.e. seeds). We propose that differential allocation of mineral resources to specific seed tissues is an indication of a species germination and establishment strategy. Burkea africana Hook is a leguminous tree typical of broad-leaved nutrient-poor savannas in southern Africa. Elemental distributions in dormant B. africana seed structures were obtained using the true elemental imaging system (Dynamic Analysis) of the NAC Van de Graaff nuclear microprobe. Raster scans of 3.0 MeV protons were complemented by simultaneous BS and PIXE point analyses. Mineral nutrient concentrations varied greatly between seed tissues. Elevated levels of metals known to play an important role as plant enzyme co-factors were found in the seed lens and embryonic axis. Distributions of most of these metals (Ca, Mn, Fe and Zn, but not K or Cu) were positively correlated with embryonic P distribution, and probably represent phytin deposits. The distribution of metals within seed structures is 'patchy' due to their complexation with P as electron-dense globoid phytin crystals, which constrains the interpretation of PIXE point analyses.

  20. The use of the RBI nuclear microprobe in conservation process studies of a church portal

    Energy Technology Data Exchange (ETDEWEB)

    Pastuovic, Z. [Ruder Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia)]. E-mail: pastu@irb.hr; Fazinic, S. [Ruder Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Jaksic, M. [Ruder Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Krstic, D. [Croatian Conservation Institute, Nike Grskovica 23, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Nike Grskovica 23, 10000 Zagreb (Croatia)

    2005-04-01

    The southern portal of the St. Marko church in Zagreb, Croatia, is currently under the process of conservation. The conservation treatments on calcareous sandstone consist of (i) removal of harmful sulfates (gypsum) from the surface of the material by saturated solution of ammonium carbonate; and (ii) treatment of the material surface with a 10% solution of barium hydroxide in order to convert the remaining dissolvable sulfates into non-dissolvable compounds and to strengthen the material surface. The nuclear microprobe has been used to measure the level of gypsum induced damage, and quality of conservation. More specifically, the surface quantity and depth concentration profiles of sulfur have been determined in several samples taken from the portal before and after the treatment with the solution of ammonium carbonate. To test the quality of treatment by the barium hydroxide solution, the depth concentration of barium in the samples has been determined after the treatment. Both sulfur and barium concentration levels have been determined by scanning the focused proton beam over the samples, detecting PIXE spectra and creating elemental distribution maps. Beside portal samples, the efficiency of the barium hydroxide treatment was tested on sandstone samples from nearby stone pit assumed to be the origin of material used for portal construction.

  1. Development of an external beam nuclear microprobe on the Aglae facility of the Louvre museum

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. E-mail: dran@culture.fr; Ioannidou, E.; Moignard, B.; Pichon, L.; Salomon, J

    2000-03-01

    The external beam line of our facility has been recently equipped with the focusing system previously mounted on a classical nuclear microprobe. When using a 0.1 {mu}m thick Si{sub 3}N{sub 4} foil for the exit window and flowing helium on the sample under analysis, a beam spot as small as 10 {mu}m is attainable at a distance of 3 mm from the window. Elemental micromapping is performed by mechanical scanning. An electronic device has been designed which allows XY scanning by moving the sample under the beam by steps down to 0.1 {mu}m. Beam monitoring is carried out by means of the weak X-ray signal emitted by the exit foil and detected by a specially designed Si(Li) detector cooled by Peltier effect. The characteristics of external beams of protons and alpha particles are evaluated by means of resonance scanning and elemental mapping of a grid. An example of application is presented, dealing with elemental micro-mapping of inclusions in gemstones.

  2. The use of the RBI nuclear microprobe in conservation process studies of a church portal

    International Nuclear Information System (INIS)

    Pastuovic, Z.; Fazinic, S.; Jaksic, M.; Krstic, D.; Mudronja, D.

    2005-01-01

    The southern portal of the St. Marko church in Zagreb, Croatia, is currently under the process of conservation. The conservation treatments on calcareous sandstone consist of (i) removal of harmful sulfates (gypsum) from the surface of the material by saturated solution of ammonium carbonate; and (ii) treatment of the material surface with a 10% solution of barium hydroxide in order to convert the remaining dissolvable sulfates into non-dissolvable compounds and to strengthen the material surface. The nuclear microprobe has been used to measure the level of gypsum induced damage, and quality of conservation. More specifically, the surface quantity and depth concentration profiles of sulfur have been determined in several samples taken from the portal before and after the treatment with the solution of ammonium carbonate. To test the quality of treatment by the barium hydroxide solution, the depth concentration of barium in the samples has been determined after the treatment. Both sulfur and barium concentration levels have been determined by scanning the focused proton beam over the samples, detecting PIXE spectra and creating elemental distribution maps. Beside portal samples, the efficiency of the barium hydroxide treatment was tested on sandstone samples from nearby stone pit assumed to be the origin of material used for portal construction

  3. Performance of a high-resolution x-ray microprobe at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Cai, Z.; Lai, B.; Yun, W.; McNulty, I.; Khounsary, A.; Maser, J.; Ilinski, P.; Legnini, D.; Trakhtenberg, E.; Xu, S.; Tieman, B.; Wiemerslage, G.; Gluskin, E.

    1999-01-01

    The authors have developed a x-ray microprobe in the energy region from 6 to 20 keV using undulator radiation and zone-plate optics for microfocusing-based techniques and applications at a beamline at the Advanced Photon Source (APS). The performance of the beamline was shown to meet the design objectives, including preservation of the source brilliance and coherence, selectable transverse coherence length and energy bandwidth, high angular stability, and harmonic suppression of the beam. These objectives were achieved by careful thermal management and use of a novel mirror and crystal monochromator cooling geometry. All beamline optical components are water cooled, and the x-ray beam in the experiment station is stable in beam intensity, energy, and position over many days with no active feedback. Using a double-crystal Si(111) monochromator, they have obtained a focal spot size (FWHM) of 0.15 (micro)m (v) x 1.0 (micro)m (h), and a photon flux of 4 x 10 9 photons/sec at the focal spot, and thus a photon flux density gain of 15,000. A circular beam spot of 0.15 (micro)m in diameter can be achieved by reducing the horizontal source size using a white beam slit located 43.5 meters upstream of the zone plate, with an order of magnitude less flux in the focal spot

  4. Application of the nuclear microprobe to the study of organic and inorganic composition of teeth irradiated by a laser beam

    International Nuclear Information System (INIS)

    Sommer, F.; Engelmann, Ch.; Couble, Ml.; Magloire, H.; Bonnin, P.

    1986-01-01

    The nuclear microprobe uses both direct observation of nuclear reactions induced by deuterons and X ray emission induced by protons or deuterons. Thanks to these techniques, concentration profiles of the main elements (C, N, P, Ca...) contained in different parts of healthy teeth (enamel, dentine and cementum) are drawn in control zones and laser irradiated zones. The results obtained show that important perturbations appear during the irradiation by the laser beam; we observe successively, depleted zones in carbon and nitrogen which contain calcium and phosphorus and hypomineralized zones which contain organic material. 10 refs [fr

  5. Nuclear microprobe study of heavy metal uptake and transport in aquatic plant species

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Kocsar, I.; Szikszai, Z.; Lakatos, Gy.

    2005-01-01

    Complete text of publication follows. In aquatic ecosystems water contamination by trace metals is one of the main types of pollution that may stress the biotic community. Although some metals are needed as micronutrients for autotrophic organisms, they can have toxic effects at higher concentration. Aquatic plants can take up large quantities of nutrients and metals from the environment, they can live under extreme environmental conditions therefore they are being increasingly used in remediation processes to reduce contamination. Besides the usually applied bulk analytical techniques quantitative micro-PIXE investigation of the macro, micro and trace element distribution within the root can lead to a better understanding of the heavy metal up-take, transport and detoxification mechanisms of the plants and thus helps to select the proper species for the remedial activity, or possibly to increase the efficiency of the remediation. In this work we determined the elemental distributions in root cross sections and along the roots of reed (Phragmaties australis), bulrush (Typha angustifolia) and sea club-rush (Bolboschoemus maritimus) using the Debrecen nuclear microprobe. The plants originate from the dried units of the wastewater sedimentation pond system of the tannery of Kunszentmarton. 1500 m 3 waste water containing lime, sodium-salts, ammonium-salts, chromium-salts, sodium, chlorine and magnesium ions, sulphur and organic material was released to the pond system every day till 1988. The chosen species are the dominant species of the area, composing 85-90% of the green plant covering. This heavily contaminated area has been regularly monitored by the colleagues of the Dept. of Applied Ecology of the Univ. of Debrecen since 1998. They focused their work the potentially toxic heavy metal chromium. In order to conserve the samples in the living state, the roots were frozen in liquid nitrogen. 16-20 μm thick cross sections were made with cryo-microtome, and all the

  6. Nuclear microprobe analysis of serpentine from the mid-Atlantic ridge

    Energy Technology Data Exchange (ETDEWEB)

    Orberger, Beate E-mail: orberger@geol.u-psud.fr; Metrich, Nicole; Mosbah, Michelle E-mail: mosbah@drecam.cea.fr; Mevel, Catherine; Fouquet, Yves

    1999-09-02

    At mid-ocean ridges, ultramafic rocks are serpentinized by interaction with seawater-derived fluids. Elements, dissolved in large quantities in seawater, e.g., Na, K, Cl, Br, Ca and Sr, can be, in small amounts, incorporated as traces into the crystal structure of the various serpentine minerals (Mg{sub 3}Si{sub 2}O{sub 5}(OH){sub 4}). These trace elements can be used to track the composition of the reacting fluids and to constrain physico-chemical conditions. This paper represents the first application of particle-induced X- and {gamma}-ray emission (PIXE/PIGE) analysis to serpentine using the nuclear microprobe at the Laboratoire Pierre Suee (CEA-CNRS). Three types of serpentine, belonging to two different serpentinization generations, have been analysed in samples collected from the Mid-Atlantic Ridge (14 deg. 45'N/45 deg. W) that exposes serpentinized peridotites on which the Logachev black smoker is placed. The trace elements Cl, F, S, Cu, Zn, Ca, K, Ni, Cr and Mn were detected from several tens to several thousands of ppm. Bromine, As and Sr are close to the detection limit of about 5 ppm. The trace element concentrations and interelement relationships in serpentines vary (a) with the serpentine type and (b) with the geographic location to the black smoker. Chlorine and in part S originated from seawater, whereas Cu, Zn, Ca, K, Ni, Cr and Fe and the major amount of S were mobilized from the unaltered host rock and partitioned between the serpentine and the aqueous solution.

  7. Nuclear microprobe analysis and source apportionment of individual atmospheric aerosol particles

    International Nuclear Information System (INIS)

    Artaxo, P.; Rabello, M.L.C.; Watt, F.; Grime, G.; Swietlicki, E.

    1993-01-01

    In atmospheric aerosol reserach, one key issue is to determine the sources of the airborne particles. Bulk PIXE analysis coupled with receptor modeling provides a useful, but limited view of the aerosol sources influencing one particular site or sample. The scanning nuclear microprobe (SNM) technique is a microanalytical technique that gives unique information on individual aerosol particles. In the SNM analyses a 1.0 μm size 2.4 MeV proton beam from the Oxford SNM was used. The trace elements with Z>11 were measured by the particle induced X-ray emission (PIXE) method with detection limits in the 1-10 ppm range. Carbon, nitrogen and oxygen are measured simultaneously using Rutherford backscattering spectrometry (RBS). Atmospheric aerosol particles were collected at the Brazilian Antarctic Station and at biomass burning sites in the Amazon basin tropical rain forest in Brazil. In the Antarctic samples, the sea-salt aerosol particles were clearly predominating, with NaCl and CaSO 4 as major compounds with several trace elements as Al, Si, P, K, Mn, Fe, Ni, Cu, Zn, Br, Sr, and Pb. Factor analysis of the elemental data showed the presence of four components: 1) Soil dust particles; 2) NaCl particles; 3) CaSO 4 with Sr; and 4) Br and Mg. Strontium, observed at 20-100 ppm levels, was always present in the CaSO 4 particles. The hierarchical cluster procedure gave results similar to the ones obtained through factor analysis. For the tropical rain forest biomass burning aerosol emissions, biogenic particles with a high organic content dominate the particle population, while K, P, Ca, Mg, Zn, and Si are the dominant elements. Zinc at 10-200 ppm is present in biogenic particles rich in P and K. The quantitative aspects and excellent detection limits make SNM analysis of individual aerosol particles a very powerful analytical tool. (orig.)

  8. Electron Microprobe

    Data.gov (United States)

    Federal Laboratory Consortium — The JEOL JXA-8600 is a conventional hairpin filament thermal emission electron microprobe that is more than 20 years old. It is capable of performing qualitative and...

  9. Contribution to the application of nuclear microprobe in geochemistry. Carbon and nitrogen microanalysis in glasses and minerals

    International Nuclear Information System (INIS)

    Mosbah, M.

    1988-01-01

    The morphological complexity of geological materials implies the use of microanalysis techniques utilization. Nuclear microprobe allows selective and no destructive light elements determination, through nuclear reactions. Nuclear microanalysis has been used to characterize carbon and nitrogen in volatile phase dissolved in magmatic samples. The application of some microanalysis techniques in geochemistry are discussed, nuclear microprobe theory and techniques are developed. Minerals, glasses and glassy inclusions are described, and more particularly, the interest of these investigations. Optimal conditions of carbon and nitrogen analysis ( 12 C(d.p) 13 C and 14 N(d,p) 15 N reaction respectively), as deuteron energy and observation angle are studied. A methodology has been established for this purpose. Several results are exposed: Punctual analysis, carbon concentration profile in depth surface scanning, surficial mapping in glassy inclusions. The carbon content interpretation in glassy inclusions measured conveniently for the first time agrees with data obtained through other techniques. In conclusion, degazing schedule improvements require more analysis. Perspective research axis are evocated [fr

  10. The Melbourne proton microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; McKenzie, C.D.; Mazzolini, A.P.

    1979-01-01

    A scanning proton microprobe is described which operates in ultra-high vacuum with a resolution of ten microns. The operating principles and main features of the design are discussed and the ability of such an instrument to detect trace elements down to a few ppm by mass is illustrated

  11. IMAP: A complete Ion Micro-Analysis Package for the nuclear microprobe

    International Nuclear Information System (INIS)

    Antolak, A.J.; Hildner, M.L.; Morse, D.H.; Bench, G.S.

    1993-01-01

    Microprobe techniques using scanned, focused MeV ions are routinely used in Livermore for materials characterization. Comprehensive data analysis with these techniques is accomplished with the computer software package IMAP, for Ion Micro-Analysis Package. IMAP consists of a set of command language procedures for data processing and quantitative spectral analysis. Deconvolution of the data is achieved by spawning sub-processes within IMAP which execute analysis codes for each specific microprobe technique. IMAP is structured to rapidly analyze individual spectra or multi-dimensional data blocks which classify individual events by the two scanning dimensions, the energy of the detected radiation and, when necessary, one sample rotation dimension. Several examples are presented to demonstrate the utility of the package

  12. Microprobe analysis of PuO2--UO2 nuclear fuel

    International Nuclear Information System (INIS)

    Clark, W.I.; Rasmussen, D.E.; Carlson, R.L.; Highley, D.M.

    1977-01-01

    For the preirradiation characterization of FFTF UO 2 --PuO 2 fuel, a program was developed to determine the preirradiation porosity, grain structure, and microcomposition of the fuel. Two computer programs, MITRAN and MERIT, were developed to evaluate the homogeneity of the fuel. These programs use elemental composition data generated by the electron microprobe. MITRAN determines information on the size and frequency of individual regions, whereas MERIT provides an index of the thermal performance of the fuel and calculated statistical data for comparison to other fuel batches

  13. Quantitative analysis of chemical elements in single cells using nuclear microprobe and nano-probe

    International Nuclear Information System (INIS)

    Deves, Guillaume

    2010-01-01

    The study of the role of trace elements at cellular level requires the use of state-of-the-art analytical tools that could achieve enough sensitivity and spatial resolution. We developed a new methodology for the accurate quantification of chemical element distribution in single cells based on a combination of ion beam analysis techniques STIM, PIXE and RBS. The quantification procedure relies on the development of a STIM data analysis software (Paparamborde). Validity of this methodology and limits are discussed here. The method allows the quantification of trace elements (μg/g) with a 19.8 % uncertainty in cellular compartments with mass below 0.1 ng. The main limit of the method lies in the poor number of samples that can be analyzed, due to long irradiation times required and limited access to ion beam analysis facilities. This is the reason why we developed a database for cellular chemical composition capitalization (BDC4). BDC4 has been designed in order to use cellular chemical composition as a tracer for biological activities and is expected to provide in the future reference chemical compositions for any cellular type or compartment. Application of the STIM-PIXE-RBS methodology to the study of nuclear toxicology of cobalt compounds is presented here showing that STIM analysis is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. (author)

  14. U-Pb geochronology of zircons form lunar Breccia 73217 using a sensitive high mass-resolution ion microprobe

    International Nuclear Information System (INIS)

    Compston, W.; Williams, I.S.

    1984-01-01

    U-Pb age determinations on four lunar zircons from existing thin-sections of one highland breccia, 73217, using the recently constructed ion microprobe SHRIMP, are reported. The analytical reproducibility of SHRIMP is demonstrated, and procedures for measuring Pb/U, Th/U, and corecting for initial Pb are explained. Electron microprobe analyses for the zircons are also reported. The results show that the four zircons survived the lunar cataclysm without any identifiable effects on their U-Pb systematics. All four indicate a single age of 4356 +23 or -14 m.y. The zircons have experienced small variable amounts of Pb loss since crystallization, from almost zero up to about 10 percent. If this occurred during one later event, then age of the latter is between 1100 and 2300 m.y. 18 references

  15. Application of a nuclear microprobe to the study of calcified tissues

    Science.gov (United States)

    Coote, Graeme E.; Vickridge, Ian C.

    1988-03-01

    The mineral fraction of calcified tissue is largely calcium hydroxyapatite (bones and teeth) or calcium carbonate (shells and fish otoliths). Apatite has such a strong affinity for fluoride ions that the F/Ca ratio can vary markedly with position in a bone or tooth, depending on the amount of fluoride present at the time of calcification or partial recrystallization. New biological information can be obtained by introducing extra fluoride into the diet of an animal and using a microprobe later to scan sections of bones or teeth. In suitable burial sites extra fluoride is introduced after death, and the new distribution may have applications in forensic science and archaeology. Fish otoliths are also of interest since a new carbonate layer is formed each day and the distribution of trace elements may record some aspects of the fish's life history. Results from the following studies are presented: fluorine distributions in the teeth of sheep which ingested extra fluoride for known periods; distributions of calcium and fluorine in femurs of rats which drank water high in fluoride for periods from 2 to 15 weeks; calcium and fluorine distributions in artificially-prepared lesions in tooth enamel; diffusion profiles in archaeological human teeth and animal bones; patterns in the strontium/calcium ratio in sectioned otoliths of several species of fish.

  16. PIXE and light element analysis (C,N) in glass inclusions trapped in meteorites with the nuclear microprobe

    International Nuclear Information System (INIS)

    Varela, M.E.; Mosbah, M.; Metrich, N.; Duraud, J.P.; Kurat, G.

    1999-01-01

    Proton-induced X-ray emission (PIXE) and light element analysis have been performed with the nuclear microprobe at the Laboratoire Pierre Suee (Saclay-France) in glass inclusions of the carbonaceous chondrites: Allende, Kaba and Renazzo, and in the achondrite meteorite: Chassigny. Carbon contents in olivine of chondrules are below the nuclear reactions analysis (NRA) detection limit, however, glasses from glass inclusions hosted by these grains, contain an appreciable and highly variable quantities of carbon (200-1600 ppm). This could indicate variable amounts of C trapped during glass inclusion formation. On the other hand, nitrogen is present in highly variable amounts in glasses of both, chondrites and achondrites minerals. Its abundance, correlated with depth from the section surface which suggests loss of N during analyses and therefore the possible existence of a very mobile (volatile?) species. A chondritic Rb/Sr and K/Rb ratio obtained by PIXE analyses in the glass-bearing inclusions of the Chassigny meteorite points towards a primitive source for the glass precursor of Chassigny inclusions

  17. Quantification of the distribution of hydrogen by nuclear microprobe at the Laboratory Pierre Sue in the width of zirconium alloy fuel clad of PWR reactors

    International Nuclear Information System (INIS)

    Raepsaet, C.; Bossis, Ph.; Hamon, D.; Bechade, J.L.; Brachet, J.C.

    2007-01-01

    Among the analysis techniques by ions beams, the micro ERDA (Elastic Detection Analysis) is an interesting technique which allows the quantitative distribution of the hydrogen in materials. In particular, this analysis has been used for hydride zirconium alloys, with the nuclear microprobe of the Laboratory Pierre Sue. This probe allows the characterization of radioactive materials. The technique principles are recalled and then two examples are provided to illustrate the fuel clad behavior in PWR reactors. (A.L.B.)

  18. Ion microprobes

    International Nuclear Information System (INIS)

    Coles, J.N.; Long, J.V.P.

    1977-01-01

    An ion microprobe is described that has an ion extraction arrangement comprising two separate paths for ions and electrons diverging from a common point. A cone shaped or pyramidal guard electrode surrounds each path the apex angles being equal and coinciding with the said point. The guard electrodes are positioned to lie tangentially to each other and to a planar surface including the said point. An aperture is provided for the two paths at the apexes of both guard electrodes, and electrical connections between the guard electrodes enable the same potential to be applied to both guard electrodes. Means are provided for generating oppositely polarised electric fields within the guard electrodes, together with means for causing a focused ion beam to strike the common point without suffering astigmatism. The means for causing a focused ion beam to strike the said point includes an ion gun for directing an ion beam along one of the paths and means to provide an axial accelerating field there along. Optical viewing means are also provided. Existing designs enable only ions or electrons, but not both, to be extracted at any one time. (U.K.)

  19. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  20. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  1. Trace element analysis in geochemistry using a nuclear microprobe. Ionoluminescence and particle induced X-ray emission

    International Nuclear Information System (INIS)

    Homman, P.

    1994-01-01

    In PIXE analysis of geological specimens based on X-ray detection with Si(Li) detectors, effects of detector tailing, pulse pileup, and gamma-ray production are pronounced. In this work the tailing effect has been addressed through characterization of the response function of a Si(Li) detector using an absorber technique. The pileup interval, in the pulse forming electronics of a PIXE detection system, has been improved to 100 ns X-ray energies above 8 keV by means of pulse shape analysis. Pulses due to tailing effects were also isolated but no major improvement was obtained. A means of reducing the increased background in the PIXE spectrum due to Compton scattering of high energetic gamma-rays in the Si(Li) crystal has been investigated by installation of an anti-Compton shield consisting of an organic scintillator mounted inside the detector cryostat and read out by a photomultiplier. Ionoluminescence, a new analytical technique for the nuclear microprobe, has shown to be a technique that can be employed as a fast diagnostic tool in imaging applications. The technique is based on analysis of the light that often can be observed when an ion beam impinges on a geological specimen. This light, luminescence, can often be associated with impurities in the crystal lattice or other structural defects. It can therefore be employed for revealing some chemical information about the specimens in contradiction to PIXE which is rather insensitive to chemical variations. The potential of the method is demonstrated and discussed both as an imaging tool and for spectroscopic studies. 19 refs, 10 figs

  2. Investigation of the Electronic Properties of Cadmium Zinc Telluride (CZT) Detectors using a Nuclear Microprobe

    International Nuclear Information System (INIS)

    BRUNETT, BRUCE A.; DOYLE, BARNEY L.; JAMES, RALPH B.; VIZKELETHY, GYORGY; WALSH, DAVID S.

    1999-01-01

    The electronic transport properties of Cadmium Zinc Telluride (CZT) determine the charge collection efficiency (i.e. the signal quality) of CZT detectors. These properties vary on both macroscopic and microscopic scale and depend on the presence of impurities and defects introduced during the crystal growth. Ion Beam Induced Charge Collection (IBICC) is a proven method to measure the charge collection efficiency. Using an ion microbeam, the charge collection efficiency can be mapped with submicron resolution, and the map of electronic properties (such as drift length) can be calculated from the measurement. A more sophisticated version of IBICC, the Time Resolved IBICC (TRIBICC) allows them to determine the mobility and the life time of the charge carriers by recording and analyzing the transient waveform of the detector signal. Furthermore, lateral IBICC and TRIBICC can provide information how the charge collection efficiency depends on the depth where the charge carriers are generated. This allows one to deduce information on the distribution of the electric field and transport properties of the charge carriers along the detector axis. IBICC and TRIBICC were used at the Sandia microbeam facility to image electronic properties of several CZT detectors. From the lateral TRIBICC measurement the electron and hole drift length profiles were calculated

  3. Nuclear microprobe and Raman investigation of the chemistry of the shell of the pacific oyster, Crassostrea gigas

    International Nuclear Information System (INIS)

    Markwitz, A.; Gauldie, R.W.; Pithie, J.; Sharma, S.K.; Jamieson, D.J.

    1999-01-01

    High-resolution nuclear microscopy was used to study the layered structure in the shell of the pacific oyster, Crassostrea gigas. In cross section, the layers appear as opaque white zones and clearer translucent zones. Raman spectroscopy indicates that the zones consist of alternating layers of the aragonite and calcite morphs of calcium carbonate, the mineral constituent of the shell. The chemistry of the shell varies from individual to individual but generally the predominant metal ion is Ca, with varying amounts of Si, Cl, Cr, Mn, Fe, Zn, Sb, Ni, Fe, As and Sr. Two dimensional maps of these major, minor and trace elements were measured in many shells with nuclear microscopy to identify the patterns of Zn and Sr deposition reflecting the calcite and aragonite layers. The significant difference in the patterns identified by ion beam analyses are possibly a result of isostructural exclusion of these metal ions between the different aragonite and calcite polymorphic forms of calcium carbonate. (author)

  4. Changes in seasonal climate patterns from 34-4 ka in a Soreq Cave (Israel) speleothem: Sub-annual resolution by ion microprobe and CLFM

    Science.gov (United States)

    Orland, I. J.; Bar-Matthews, M.; Kita, N.; Ayalon, A.; Valley, J. W.

    2009-12-01

    Speleothems provide an important proxy-record of paleoclimate. Isotopic data from calcite-dominated cave formations have been used to identify changes in annual rainfall, monsoon strength, telecommunication of Northern Hemisphere climate aberrations, changes in vegetation cover, and other region-specific paleoclimate time-series over annual to millennial timescales. As more research is devoted to understanding abrupt climate change events, there is a need to develop high-temporal-resolution records from continental regions. However, in most isotopic studies, seasonality information is lost due to technical limitations. This study focuses on a speleothem from the semi-arid Eastern Mediterranean region (Soreq Cave, Israel) where prior research shows that conventional drill-sampling methods permit a temporal resolution of ~10-50 years in speleothem paleoclimate records. The WiscSIMS lab has developed analytical protocols for ion microprobe analysis that yield a precision of ~0.3‰ (2 s.d.) in δ18O from 10 μm-diameter spots, which permit multiple analyses/year in many speleothems. Orland et al. (2009, Quat. Res.) establish the methodology for the current study by identifying seasonal variability using a combination of confocal laser fluorescent microscopy (CLFM) and ion microprobe analysis in a younger (~2-1 ka) Soreq speleothem that has a consistent bright-grading-to-dark fluorescence pattern within each annual band. Further, Orland et al. define a quantitative measure of seasonality, Δ18O, that measures the difference in δ18O between bright and dark fluorescent portions of individual annual growth bands [Δ18O = δ18Odark - δ18Obright]. Smaller values of Δ18O are interpreted to be caused by dry years. The current study employs the aforementioned methods to examine seasonality trends in a sample that covers a much longer time period. We report δ18O from >1000 spots across a radial traverse of Soreq Cave sample 2N matched to imaging of annual growth bands by

  5. Nuclear microprobe characterization of surface hardening by precipitation of chromium carbides after laser beam treatment of a Ni-Cr substrate

    International Nuclear Information System (INIS)

    Mosbah, M.; Gosset, J.; Trocellier, P.; Puig, T.; Cantarel, M.; Condat, M.

    1989-01-01

    Surface treatment by laser provides interesting solutions to the problem of accelerated wear of materials. The aim of the present study is the characterization of chromium carbides rich surface alloys after laser beam melting of a Ni 70 Cr 30 carbon precoated substrate. The carbon profiling of the lasered surface was performed by nuclear microprobe using the 12 C(d,p 0 ) 13 C reaction, Ni and Cr were evaluated by means of PIXE (Particle Induced X Ray Emission). The specificity of the method and the experimental conditions are explained. Wear results are very satisfactory and close to those obtained by injection of chromium carbide powders into the laser beam in the case of a Nimonic alloy: wear rates are divided by two orders of magnitude

  6. Ion microprobe Sr isotope analysis of carbonates with about 5 {mu}m spatial resolution: An example from an ayu otolith

    Energy Technology Data Exchange (ETDEWEB)

    Sano, Yuji [Center for Advanced Marine Research, Ocean Research Institute, University of Tokyo, Nakano-ku, Tokyo 164-8639 (Japan)], E-mail: ysano@ori.u-tokyo.ac.jp; Shirai, Kotaro [International Coastal Research Center, Ocean Research Institute, University of Tokyo, Otsuchi, Iwate 028-1102 (Japan); Takahata, Naoto; Amakawa, Hiroshi [Center for Advanced Marine Research, Ocean Research Institute, University of Tokyo, Nakano-ku, Tokyo 164-8639 (Japan); Otake, Tsuguo [International Coastal Research Center, Ocean Research Institute, University of Tokyo, Otsuchi, Iwate 028-1102 (Japan)

    2008-08-15

    A high lateral resolution secondary ion mass spectrometer (NanoSIMS NS50 ion microprobe) has been used to measure {sup 87}Sr/{sup 86}Sr ratios in natural CaCO{sub 3} samples. A {approx}2 nA O{sup -} primary beam was used to sputter a 5-7-{mu}m diameter crater on the sample surface and secondary positive ions were extracted for mass analysis using an accelerating voltage of 8 kV and a Mattauch-Herzog geometry. The multi-collector system was adjusted to detect {sup 43}Ca{sup +} (by a detector EM2), {sup 80}Ca{sub 2}{sup +} (EM3), {sup 86}Sr{sup +} (EM4), and {sup 87}Sr{sup +} (EM4b) ions at the same time. Then the magnetic field was scanned for the EM4 to detect {sup 85}Rb{sup +}, {sup 86}Sr{sup +} and {sup 87}Sr{sup +}, while the EM4b can measure {sup 86}Sr{sup +}, {sup 87}Sr{sup +} and {sup 88}Sr{sup +}, respectively. A mass resolution of 3600 at 10% peak height was attained with a flat peak top, while the sensitivity of Sr was about 10 cps/nA/ppm. An aragonite sample (coral skeleton standard; JCp-1) was used as a reference for Sr isotope ratio calibration. Repeated analyses of the JCp-1 show that the {sup 87}Sr/{sup 86}Sr ratio agrees well with the seawater signature within a precision of 0.3 per mille at 2{sigma}, after the series of corrections such as the Ca dimer, {sup 87}Rb, and a mass bias estimated by the {sup 88}Sr/{sup 86}Sr ratio. The method was applied to an otolith (ear-stone) from ayu (Plecoglossus altivelis altivelis) collected from the Yodo river, Japan. Although experimental errors are relatively large, up to 3 per mille at 2{sigma}, the ratios of the core region are higher than the seawater signature while more distal values agree well with seawater. The very outermost part again shows the relatively higher {sup 87}Sr/{sup 86}Sr ratios. The spatial variation of {sup 87}Sr/{sup 86}Sr ratios was consistent with amphidromous migration of the fish, namely, born in the lake and grown in the coastal sea and finally collected in a river.

  7. Ion microprobe Sr isotope analysis of carbonates with about 5 μm spatial resolution: An example from an ayu otolith

    International Nuclear Information System (INIS)

    Sano, Yuji; Shirai, Kotaro; Takahata, Naoto; Amakawa, Hiroshi; Otake, Tsuguo

    2008-01-01

    A high lateral resolution secondary ion mass spectrometer (NanoSIMS NS50 ion microprobe) has been used to measure 87 Sr/ 86 Sr ratios in natural CaCO 3 samples. A ∼2 nA O - primary beam was used to sputter a 5-7-μm diameter crater on the sample surface and secondary positive ions were extracted for mass analysis using an accelerating voltage of 8 kV and a Mattauch-Herzog geometry. The multi-collector system was adjusted to detect 43 Ca + (by a detector EM2), 80 Ca 2 + (EM3), 86 Sr + (EM4), and 87 Sr + (EM4b) ions at the same time. Then the magnetic field was scanned for the EM4 to detect 85 Rb + , 86 Sr + and 87 Sr + , while the EM4b can measure 86 Sr + , 87 Sr + and 88 Sr + , respectively. A mass resolution of 3600 at 10% peak height was attained with a flat peak top, while the sensitivity of Sr was about 10 cps/nA/ppm. An aragonite sample (coral skeleton standard; JCp-1) was used as a reference for Sr isotope ratio calibration. Repeated analyses of the JCp-1 show that the 87 Sr/ 86 Sr ratio agrees well with the seawater signature within a precision of 0.3 per mille at 2σ, after the series of corrections such as the Ca dimer, 87 Rb, and a mass bias estimated by the 88 Sr/ 86 Sr ratio. The method was applied to an otolith (ear-stone) from ayu (Plecoglossus altivelis altivelis) collected from the Yodo river, Japan. Although experimental errors are relatively large, up to 3 per mille at 2σ, the ratios of the core region are higher than the seawater signature while more distal values agree well with seawater. The very outermost part again shows the relatively higher 87 Sr/ 86 Sr ratios. The spatial variation of 87 Sr/ 86 Sr ratios was consistent with amphidromous migration of the fish, namely, born in the lake and grown in the coastal sea and finally collected in a river

  8. Numerical studies of triplet and Russian quadruplet quadrupole lens systems with the given spot size on the target, for use in a microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Brazhnik, V A; Lebed, S A; Ponomarev, A G; Storizhko, V E [Ukrainian Academy of Sciences, Sumy (Ukraine). Applied Physics Institute; Dymnikov, A D [University of St Petersburg, Stary (Russian Federation). Institute of Computational Mathematics and Control Processes; Jamieson, D N; Legge, S A [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    In a nuclear microprobe the focusing system is an essential component which determines the beam spot size, i.e. the microprobe resolution. A small beam cross section at the target is the most important of the many conflicting requirements imposed on the beam The second most important factor is the current of the beam which at the given brightness is proportional to the phase volume (or emittance) of the beam. Existing microprobes frequently use a triplet or a Russian quadruplet as the focusing systems. This paper describes the numerical studies of some optimal quadrupole lens systems consisting of three or four lenses suitable for use in a nuclear microprobe taking into account geometrical aberrations of third order. The maximum emittance of changed particle beams for these systems has been found. It is shown how the maximum emittance depends on the spot size. 2 refs., 2 figs.

  9. Numerical studies of triplet and Russian quadruplet quadrupole lens systems with the given spot size on the target, for use in a microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Brazhnik, V.A.; Lebed, S.A.; Ponomarev, A.G.; Storizhko, V.E. [Ukrainian Academy of Sciences, Sumy (Ukraine). Applied Physics Institute; Dymnikov, A.D. [University of St Petersburg, Stary (Russian Federation). Institute of Computational Mathematics and Control Processes; Jamieson, D.N.; Legge, S.A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    In a nuclear microprobe the focusing system is an essential component which determines the beam spot size, i.e. the microprobe resolution. A small beam cross section at the target is the most important of the many conflicting requirements imposed on the beam The second most important factor is the current of the beam which at the given brightness is proportional to the phase volume (or emittance) of the beam. Existing microprobes frequently use a triplet or a Russian quadruplet as the focusing systems. This paper describes the numerical studies of some optimal quadrupole lens systems consisting of three or four lenses suitable for use in a nuclear microprobe taking into account geometrical aberrations of third order. The maximum emittance of changed particle beams for these systems has been found. It is shown how the maximum emittance depends on the spot size. 2 refs., 2 figs.

  10. Numerical studies of triplet and Russian quadruplet quadrupole lens systems with the given spot size on the target, for use in a microprobe

    International Nuclear Information System (INIS)

    Brazhnik, V.A.; Lebed, S.A.; Ponomarev, A.G.; Storizhko, V.E.; Dymnikov, A.D.; Jamieson, D.N.; Legge, S.A.

    1993-01-01

    In a nuclear microprobe the focusing system is an essential component which determines the beam spot size, i.e. the microprobe resolution. A small beam cross section at the target is the most important of the many conflicting requirements imposed on the beam The second most important factor is the current of the beam which at the given brightness is proportional to the phase volume (or emittance) of the beam. Existing microprobes frequently use a triplet or a Russian quadruplet as the focusing systems. This paper describes the numerical studies of some optimal quadrupole lens systems consisting of three or four lenses suitable for use in a nuclear microprobe taking into account geometrical aberrations of third order. The maximum emittance of changed particle beams for these systems has been found. It is shown how the maximum emittance depends on the spot size. 2 refs., 2 figs

  11. Characterization of flux-grown Trace-element-doped titanite using the high-mass-resolution ion microprobe (SHRIMP-RG)

    Science.gov (United States)

    Mazdab, F.K.

    2009-01-01

    Crystals of titanite can be readily grown under ambient pressure from a mixture of CaO, TiO2 and SiO2 in the presence of molten sodium tetraborate. The crystals produced are euhedral and prismatic, lustrous and transparent, and up to 5 mm in length. Titanite obtained by this method contains approximately 4300 ppm Na and 220 ppm B contributed from the flux. In addition to dopant-free material, titanite containing trace alkali and alkaline earth metals (K, Sr, Ba), transition metals (Sc, Cr, Ni, Y, Zr, Nb, Hf and Ta), rare-earth elements (REE), actinides (Th, U) and p-block elements (F, S, Cl, Ge, Sn and Pb) have been prepared using the same procedure. Back-scattered electron (BSE) imaging accompanied by ion-microprobe (SHRIMP-RG) analysis confirms significant incorporation of selected trace-elements at structural sites. Regardless of some zonation, the large size of the crystals and broad regions of chemical homogeneity make these crystals useful as experimental starting material, and as matrix-matched trace-element standards for a variety of microbeam analytical techniques where amorphous titanite glass, heterogeneous natural titanite or a non-titanite standard may be less than satisfactory. Trace-element-doped synthetic crystals can also provide a convenient proxy for a better understanding of trace-element incorporation in natural titanite. Comparisons with igneous, authigenic and high-temperature metasomatic titanite are examined. The use of high-mass-resolution SIMS also demonstrates the analytical challenges inherent to any in situ mass-spectrometry-based analysis of titanite, owing to the production of difficult-to-resolve molecular interferences. These interferences are dominated by Ca-Ca, Ca-Ti and Ti-Ti dimers that are significant in the mass range of 80-100, affecting all isotopes of Sr and Zr, as well as 89Y and 93Nb. Methods do exist for the evaluation of interferences by these dimers and of polyatomic interferences on the LREE.

  12. High current pulsed positron microprobe

    International Nuclear Information System (INIS)

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  13. Microprobing of nuclear-dangerous materials in object << Shelter >>.; Mikrozondirovanie yadernoopasnykh delyashchikhsya materialov v ob`ekte << Ukrytie >>.

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, S I; Shostak, V B; Shcherbina, V G [Kievskij Gosudarstvennyj Univ., Kiev (Ukraine); [Myizhgaluzevij Naukovo-Tekhnyichnij Tsentr ` ` Ukrittya ` ` , Natsyional` na Akademyiya Nauk Ukrayini, Chornobil` (Ukraine)

    1994-12-31

    Peculiarities of neutron echo from the nuclear fuel induced by fission have been devised for solving problems of nuclear and radiation safety of object << Shelter >>. Practical scheme of this method for definition of the structure and situation of nuclear fuel is suggested.

  14. Combining Raman Microprobe and XPS to Study High Temperature Oxidation of Metals

    International Nuclear Information System (INIS)

    Windisch, Charles F.; Henager, Charles H.; Engelhard, Mark H.; Bennett, Wendy D.

    2011-01-01

    Raman microprobe spectroscopy was applied in studies of high-temperature air oxidation of a ferritic alloy (HT-9) in the absence and presence of zirconia coatings with the objective of evaluating the technique as a way to quickly screen candidate cladding materials and actinide-based mixed oxide fuel mixtures for advanced nuclear reactors. When oxidation was relatively uniform, Raman spectra collected using microscope optics with low spatial resolution were found to be similar to those collected with conventional Raman spectroscopy. These spectra could be used to identify major oxide corrosion products and follow changes in the composition of the oxides due to heating. However, when the oxidation films were comprised of multiple layers of varying composition, or with layers containing metallic phases, techniques with higher depth resolution and sensitivity to zero-valence metals were necessary. The requirements were met by combining Raman microprobe using different optical configurations and x-ray photoelectron spectroscopy.

  15. Metabolite localization by atmospheric pressure high-resolution scanning microprobe matrix-assisted laser desorption/ionization mass spectrometry imaging in whole-body sections and individual organs of the rove beetle Paederus riparius.

    Science.gov (United States)

    Bhandari, Dhaka Ram; Schott, Matthias; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-03-01

    Mass spectrometry imaging provides for non-targeted, label-free chemical imaging. In this study, atmospheric pressure high-resolution scanning microprobe matrix-assisted laser desorption/ionization mass spectrometry imaging (AP-SMALDI MSI) was used for the first time to describe the chemical distribution of the defensive compounds pederin, pseudopederin, and pederon in tissue sections (16 μm thick) of the rove beetle Paederus riparius. The whole-insect tissue section was scanned with a 20-μm step size. Mass resolution of the orbital trapping mass spectrometer was set to 100,000 at m/z 200. Additionally, organ-specific compounds were identified for brain, nerve cord, eggs, gut, ovaries, and malpighian tubules. To confirm the distribution of the specific compounds, individual organs from the insect were dissected, and MSI experiments were performed on the dissected organs. Three ganglia of the nerve cord, with a dimension of 250-500 μm, were measured with 10-μm spatial resolution. High-quality m/z images, based on high spatial resolution and high mass accuracy were generated. These features helped to assign mass spectral peaks with high confidence. Mass accuracy of the imaging experiments was section. Without any labeling, we assigned key lipids for specific organs to describe their location in the body and to identify morphological structures with a specificity higher than with staining or immunohistology methods.

  16. Nuclear microprobe investigation into the trace elemental contents of carotid artery walls of apolipoprotein E deficient mice

    International Nuclear Information System (INIS)

    Ren Minqin; Huang En; Beck, Konstanze; Rajendran, Reshmi; Wu, Ben J.; Halliwell, Barry; Watt, Frank; Stocker, Roland

    2007-01-01

    Atherosclerosis is a progressive disease that causes lesions in large and medium-sized arteries. There is increasing evidence that the function of vascular endothelial cells is impaired by oxidation reactions, and that metal ions may participate in these processes. The nuclear microscopy facility in NUS, which has the ability to focus a 2 MeV proton beam down to sub micron spot sizes, was used to investigate the trace elemental changes (e.g. Zn and Fe) in atherosclerotic lesions in the common carotid artery of apolipoprotein E deficient mice fed a high fat diet. In this preliminary study, which is part of a larger study to investigate the effects of probucol on carotid artery atherosclerosis, two sets of mice were used; a test set fed a high fat diet +1% probucol, and a control set which was fed a high fat diet only. The results show that the Zn/Fe ratio was significantly higher in the media of arteries of probucol treated animals without overlying lesion (4.3) compared to the media with overlying lesion (1.3) (p = 0.004) for test mice. For the control mice, the arterial Zn/Fe ratio was 1.8 for media without overlying lesion, compared with 1.0 for media with overlying lesion (p = 0.1). Thus, for media without overlying lesion, the Zn/Fe ratio was significantly higher (p = 0.009) in probucol-treated (4.3) than control mice (1.8), whereas there was little difference in the ratios between the two groups in media with overlying lesion (1.3 compared with 1.0). These preliminary results are consistent with the idea that the levels of iron and zinc concentrations within the artery wall may influence the formation of atherosclerotic plaque in the carotid artery

  17. Optimization of the electrostatic structure of the ion microprobe

    Directory of Open Access Journals (Sweden)

    I. G. Ignat'ev

    2012-03-01

    Full Text Available The paper presents optimization data obtained for an immersion probe-forming system of the ion microprobe to be used in 3 MeV H+ ion accelerator generating 0,4 μm beam spot for normalized acceptance of 7 μm2 · mrad2 · MeV. To achieve higher microprobe resolution it is intended to place an electrostatic lens between the collimators and the accelerating tube.

  18. Automated electron microprobe

    International Nuclear Information System (INIS)

    Thompson, K.A.; Walker, L.R.

    1986-01-01

    The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area

  19. Phospholipid Topography of Whole-Body Sections of the Anopheles stephensi Mosquito, Characterized by High-Resolution Atmospheric-Pressure Scanning Microprobe Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging.

    Science.gov (United States)

    Khalil, Saleh M; Römpp, Andreas; Pretzel, Jette; Becker, Katja; Spengler, Bernhard

    2015-11-17

    High-resolution atmospheric-pressure scanning microprobe matrix-assisted laser desorption/ionization mass spectrometry imaging (AP-SMALDI MSI) has been employed to study the molecular anatomical structure of rodent malaria vector Anopheles stephensi mosquitoes. A dedicated sample preparation method was developed which suits both, the special tissue properties of the sample and the requirements of high-resolution MALDI imaging. Embedding in 5% carboxymethylcellulose (CMC) was used to maintain the tissue integrity of the whole mosquitoes, being very soft, fragile, and difficult to handle. Individual lipid compounds, specifically representing certain cell types, tissue areas, or organs, were detected and imaged in 20 μm-thick whole-body tissue sections at a spatial resolution of 12 μm per image pixel. Mass spectrometric data and information quality were based on a mass resolution of 70,000 (at m/z 200) and a mass accuracy of better than 2 ppm in positive-ion mode on an orbital trapping mass spectrometer. A total of 67 imaged lipids were assigned by database search and, in a number of cases, identified via additional MS/MS fragmentation studies directly from tissue. This is the first MSI study at 12 μm spatial resolution of the malaria vector Anopheles. The study provides insights into the molecular anatomy of Anopheles stephensi and the distribution and localization of major classes of glycerophospholipids and sphingolipids. These data can be a basis for future experiments, investigating, e.g., the metabolism of Plasmodium-infected and -uninfected Anopheles mosquitoes.

  20. Beam developments for the Harwell microprobe system

    International Nuclear Information System (INIS)

    Read, P.M.; Cookson, J.A.; Alton, G.D.

    1986-01-01

    A consequence of the rapid development of micron and submicron size electronic devices is the diminished applicability of high energy ion microprobes with their present resolution limitations to the study of such components. Although submicron beams have been reported the available beam current is barely sufficiently for PIXE and is not adequate for RBS. This lack of lateral resolution is due to low beam brightness at the microprobe object and aberrations in the focusing elements. As part of a program to address these problems the Harwell microprobe lens has been relocated on a new 5 MV Laddertron accelerator. The increased brightness and improved stability of this facility has so far led to a reduction in beam size from 3 x 3 μm 2 to about 2 x 2 μm 2 . The feasibility of using a liquid metal ion source has been examined with a view to achieving more substantial increases in brightness. While such sources have brightness approximately 10 5 times greater than conventional gaseous sources the highly divergent nature of the beam presents problems for the beam transport system. The use of a liquid metal source on the accelerator has been successfully demonstrated but it indicates the need for a special low aberration injection lens if brightness is to be maintained

  1. 7th international conference on Nuclear microprobe technology and applications; 7. conference internationale sur la technologie et les applications des microsondes nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This colloquium gives an up-to-date report on the continuously advancing applications and development of microbeam technology. It presents abstracts and oral contributions in the following domains: microprobes facilities, analysis techniques, imaging techniques, micro-ion beam modification of materials, microelectronics, applications in Material Sciences in Biology in Medicine in earth and planetary Sciences in environment in art in archaeology, alternative techniques. (A.L.B.)

  2. High Resolution Sensor for Nuclear Waste Characterization

    International Nuclear Information System (INIS)

    Kanai Shah; William Higgins; Edgar V. Van Loef

    2006-01-01

    Gamma ray spectrometers are an important tool in the characterization of radioactive waste. Important requirements for gamma ray spectrometers used in this application include good energy resolution, high detection efficiency, compact size, light weight, portability, and low power requirements. None of the available spectrometers satisfy all of these requirements. The goal of the Phase I research was to investigate lanthanum halide and related scintillators for nuclear waste clean-up. LaBr 3 :Ce remains a very promising scintillator with high light yield and fast response. CeBr 3 is attractive because it is very similar to LaBr 3 :Ce in terms of scintillation properties and also has the advantage of much lower self-radioactivity, which may be important in some applications. CeBr 3 also shows slightly higher light yield at higher temperatures than LaBr 3 and may be easier to produce with high uniformity in large volume since it does not require any dopants. Among the mixed lanthanum halides, the light yield of LaBr x I 3-x :Ce is lower and the difference in crystal structure of the binaries (LaBr 3 and LaI 3 ) makes it difficult to grow high quality crystals of the ternary as the iodine concentration is increased. On the other hand, LaBr x I 3-x :Ce provides excellent performance. Its light output is high and it provides fast response. The crystal structures of the two binaries (LaBr 3 and LaCl 3 ) are very similar. Overall, its scintillation properties are very similar to those for LaBr 3 :Ce. While the gamma-ray stopping efficiency of LaBr x I 3-x :Ce is lower than that for LaBr 3 :Ce (primarily because the density of LaCl 3 is lower than that of LaBr 3 ), it may be easier to grow large crystals of LaBr x I 3-x :Ce than LaBr 3 :Ce since in some instances (for example, Cd x Zn 1-x Te), the ternary compounds provide increased flexibility in the crystal lattice. Among the new dopants, Eu 2+ and Pr 3+ , tried in LaBr 3 host crystals, the Eu 2+ doped samples exhibited

  3. Subgroup report on hard x-ray microprobes

    International Nuclear Information System (INIS)

    Ice, G.E.; Barbee, T.; Bionta, R.; Howells, M.; Thompson, A.C.; Yun, W.

    1994-01-01

    The increasing availability of synchrotron x-ray sources has stimulated the development of advanced hard x-ray (E≥5 keV) microprobes. New x-ray optics have been demonstrated which show promise for achieving intense submicron hard x-ray probes. These probes will be used for extraordinary elemental detection by x-ray fluorescence/absorption and for microdiffraction to identify phase and strain. The inherent elemental and crystallographic sensitivity of an x-ray microprobe and its inherently nondestructive and penetrating nature makes the development of an advanced hard x-ray microprobe an important national goal. In this workshop state-of-the-art hard x-ray microprobe optics were described and future directions were discussed. Gene Ice, Oak Ridge National Laboratory (ORNL), presented an overview of the current status of hard x-ray microprobe optics and described the use of crystal spectrometers to improve minimum detectable limits in fluorescent microprobe experiments. Al Thompson, Lawrence Berkeley Laboratory (LBL), described work at the Center for X-ray Optics to develop a hard x-ray microprobe based on Kirkpatrick-Baez (KB) optics. Al Thompson also showed the results of some experimental measurements with their KB optics. Malcolm Howells presented a method for bending elliptical mirrors and Troy Barbee commented on the use of graded d spacings to achieve highest efficiency in KB multilayer microfocusing. Richard Bionta, Lawrence Livermore National Laboratory (LLNL), described the development of the first hard x-ray zone plates and future promise of so called open-quotes jelly rollclose quotes or sputter slice zone plates. Wenbing Yun, Argonne National Laboratory (ANL), described characterization of jelly roll and lithographically produced zone plates and described the application of zone plates to focus extremely narrow bandwidths by nuclear resonance. This report summarizes the presentations of the workshop subgroup on hard x-ray microprobes

  4. The North Korean Nuclear Crisis: Outcome and Resolution

    International Nuclear Information System (INIS)

    Lee, Seung-Keun

    2011-01-01

    This paper focuses on the North Korean nuclear crisis and how to find the best method of dismantling the North's nuclear facilities. From empirical studies of North Korean negotiating behavior, strategy, intentions and future of the regime, North Korea seems unlikely to abandon its nuclear program, if left unconstrained. This paper analyzes North Korean nuclear strategy and discusses problems concerned with the North Korean nuclear issues. It will propose some resolutions for a comprehensive approach in order to find a solution to the North Korean nuclear threat: restarting the six-party talks; preparation of a sophisticated nuclear elimination road-map; encouraging the gradual transformation of North Korea and its integration into the international community. In the long run, when North Korean nuclear strategy is considered, dialogue and engagement combined with international pressure or proper sanctions is needed

  5. The resolution of discrepancies among nuclear data

    International Nuclear Information System (INIS)

    Peelle, R.

    1992-01-01

    Significant differences among input data occur in the evaluation of nuclear data because it is difficult to achieve experimental results with the accuracy required for some applications. Types of ''discrepancies'' are classified. The means are reviewed by which an evaluator may treat discrepancies in the process of evaluation. When all means fail that are based on how the discrepant data were obtained, the perplexed evaluator must sometimes combine discrepant data based just on the stated values and uncertainties; techniques for treating such challenges are compared. Some well-known data discrepancies are examined as examples

  6. Development of ultrahigh energy resolution gamma spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Drury, O.B.; Velazquez, M.; Dreyer, J.G.; Friedrich, S.

    2009-01-01

    We are developing superconducting ultrahigh resolution gamma-detectors for non-destructive analysis (NDA) of nuclear materials, and specifically for spent fuel characterization in nuclear safeguards. The detectors offer an energy resolution below 100 eV FWHM at 100 keV, and can therefore significantly increase the precision of NDA at low energies where line overlap affects the errors of the measurement when using germanium detectors. They also increase the peak-to-background ratio and thus improve the detection limits for weak gamma emissions from the fissile Pu and U isotopes at low energy in the presence of an intense Compton background from the fission products in spent fuel. Here we demonstrate high energy resolution and high peak-to-background ratio of our superconducting Gamma detectors, and discuss their relevance for measuring actinides in spent nuclear fuel. (author)

  7. Use of the ion microprobe in geological dating

    International Nuclear Information System (INIS)

    Compston, W.; Williams, I.S.; Black, L.P.

    1983-01-01

    SHRIMP, the Sensitive High Resolution Ion Microprobe with computerised control and data acquisition system, has recently been commissioned. It is used within the Research School of Earth Sciences, Australian National University, for the isotopic analysis of geological samples. Principles of operation and geological applications are outlined. One example described is the application to Pb-U dating of zircon

  8. Proton microprobe analysis of zinc in skeletal tissues

    Science.gov (United States)

    Doty, S. B.; Jones, K. W.; Kraner, H. W.; Shroy, R. E.; Hanson, A. L.

    1981-03-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determination in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage.

  9. Proton microprobe analysis of zinc in skeletal tissues

    International Nuclear Information System (INIS)

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1980-06-01

    A proton microprobe with windowless exit port was used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage

  10. Microprobe channeling analysis of pyrite crystals

    International Nuclear Information System (INIS)

    Jamieson, D.N.; Ryan, C.G.

    1992-01-01

    Nuclear microprobe analysis has provided much useful information about the composition of microscopic inclusions in minerals, mainly through the use of Particle Induced X-ray Emission (PIXE). However this technique, while powerful, does not provide any direct information about the chemical state, in particular the lattice location, of the elements in the mineral. This information is often of crucial importance in understanding the ore genesis. The technique of ion channeling may be used to identify lattice location, but many minerals occur as microscopic crystals. Therefore it is necessary to utilize a nuclear microprobe with the technique of Channeling Contrast Microscopy (CCM). As many minerals contain interesting trace elements, it is necessary to measure both the yield of backscattered particles and the induced x-rays to get a clear picture of the lattice location of the elements in the crystal. CCM with PIXE was used to analyse natural pyrite crystals containing a variety of substitutional and non-substitutional elements and natural pyrite crystals from a gold bearing ore. In the latter case, evidence was obtained for two habits for Au in the 400 μm crystals: one as inclusions of Au rich minerals, the other substituted on the pyrite lattice sites. 31 refs., 3 tabs., 6 figs

  11. Microprobe analysis in human pathology

    International Nuclear Information System (INIS)

    Baker, D.; Kupke, K.G.; Ingram, P.; Roggli, V.L.; Shelburne, J.D.

    1985-01-01

    This tutorial paper reviews the literature on the application of microprobe analysis to practical problems in diagnostic human pathology. The goal is to allow the reader ready access to the literature on specific clinical problems. Specimen preparation and commonly encountered artifacts are also considered. It is concluded that energy dispersive x-ray microanalysis and back-scattered electron imaging are at present the most generally useful microprobe techniques for clinical work, and are no longer solely research tools. The findings often have diagnostic, therapeutic, and/or legal implications. 332 references

  12. Microprobe analysis of human fibroblasts

    International Nuclear Information System (INIS)

    Allan, G.L.; Zhu, J.; Legge, G.J.F.

    1985-01-01

    The Melbourne Proton Microprobe has been used to study the copper content in human skin fibroblast cells derived from patients with the genetic disease Menkes Syndrome. Both normal and diseased cells have been studied to investigate any elemental differences occurring between the two cell types. This paper details the preparatory techniques necessary for individual cell analysis and presents the elemental information with a new three dimensional contour mapping technique. These maps are used to highlight elemental differences between normal and mutant fibroblasts. The work also confirms the expected copper excess found in the Menkes cell and indicates that the microprobe can be used for rapid identification of a Menkes carrier

  13. Dispute resolution in the nuclear waste repository program

    International Nuclear Information System (INIS)

    Creighton, J.L.; Shorett, A.J.

    1988-01-01

    During 1987 a seven-person team addressed just that question for the State of Washington, as part of the studies of the socioeconomic impacts of a possible nuclear waste repository site at the Hanford site. The authors were, respectively, the Mitigation/Compensation team leader and the conflict resolution specialist within the team. While the studies were terminated when Congress selected the Nevada site, the conclusions may still have value for the State of Nevada, or for other controversial federal projects

  14. Fine grained nuclear emulsion for higher resolution tracking detector

    Energy Technology Data Exchange (ETDEWEB)

    Naka, T., E-mail: naka@flab.phys.nagoya-u.ac.jp [Institute of Advanced Research, Nagoya University, Nagoya (Japan); Asada, T.; Katsuragawa, T.; Hakamata, K.; Yoshimoto, M.; Kuwabara, K.; Nakamura, M.; Sato, O.; Nakano, T. [Graduated School of Science, Nagoya University, Nagoya (Japan); Tawara, Y. [Division of Energy Science, EcoTopia Science Institute, Nagoya University, Nagoya (Japan); De Lellis, G. [INFN Sezione di Napoli, Napoli (Italy); Sirignano, C. [INFN Sezione di Padova, Padova (Italy); D' Ambrossio, N. [INFN, Laboratori Nazionali del Gran Sasso, Assergi (L' Aquila) (Italy)

    2013-08-01

    Fine grained nuclear emulsion with several 10 nm silver halide crystals can detect submicron tracks. This detector is expected to be worked as dark matter detector with directional sensitive. Now, nuclear emulsion became possible to be produced at Nagoya University, and extreme fine grained nuclear emulsion with 20 nm diameter was produced. Using this emulsion and new reading out technique with expansion technique, for optical selection and X-ray microscopy, recoiled tracks induced by dark matter can be detected automatically. Then, readout efficiency is larger than 80% at 120 nm, and angular resolution for final confirmation with X-ray microscopy is 20°. In addition, we started to construct the R and D underground facility in Gran Sasso.

  15. Quantification of the distribution of hydrogen by nuclear microprobe at the Laboratory Pierre Sue in the width of zirconium alloy fuel clad of PWR reactors; Quantification de la repartition de l'hydrogene a la microsonde nucleaire du Laboratoire Pierre Sue dans l'epaisseur de tubes de gainage du combustible des REP en alliage de zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Raepsaet, C. [CEA Saclay, Dept. de Recherche sur l' Etat Condense, les Atomes et les Molecules (DSM/DRECAM/LPS-CNRS) UMR9956, 91 - Gif sur Yvette (France); Bossis, Ph. [CEA Saclay, Dept. des Materiaux pour le Nucleaire (DEN/DANS/DMN/SEMULM2E), 91 - Gif-sur-Yvette (France); Hamon, D.; Bechade, J.L.; Brachet, J.C. [CEA Saclay, Dept. des Materiaux pour le Nucleaire (DEN/DANS/DMN/SRMALA2M), 91 - Gif-sur-Yvette (France)

    2007-07-01

    Among the analysis techniques by ions beams, the micro ERDA (Elastic Detection Analysis) is an interesting technique which allows the quantitative distribution of the hydrogen in materials. In particular, this analysis has been used for hydride zirconium alloys, with the nuclear microprobe of the Laboratory Pierre Sue. This probe allows the characterization of radioactive materials. The technique principles are recalled and then two examples are provided to illustrate the fuel clad behavior in PWR reactors. (A.L.B.)

  16. New electron microprobe for radioactive materials

    International Nuclear Information System (INIS)

    Perrot, M.; Geoffroy, G.; Trotabas, M.

    1989-01-01

    The latest model of CAMECA microprobe SX 50R has just been set up in the high activity laboratory of the Centre d'Etudes Nucleaires de SACLAY. It has been especially designed for the examination of nuclear fuel and irradiated materials. The spectrometers are protected from the radioactivity by an armour plate and the entire equipment has been installed into a special cell in order to protect the operators. The special sample holder allows to examine specimens as large as 80 mm in diameter. One of the interesting uses concerns the quantitative determination of the oxygen content in zircaloy oxidized by steam at high temperature. This analysis was made possible by using the new type of crystals (multilayer)

  17. Wavelength dispersive μPIXE setup for the ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Fazinić, S., E-mail: stjepko.fazinic@irb.hr [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Božičević Mihalić, I.; Tadić, T.; Cosic, D.; Jakšić, M. [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Grškovićeva 23, 10000 Zagreb (Croatia)

    2015-11-15

    We have developed a small wavelength dispersive X-ray spectrometer to explore the possibility of performing chemical speciation on microscopic samples utilizing focused ion beams available at the Rudjer Boskovic Institute ion microprobe. Although PIXE spectra are in principle chemically invariant, small influence of chemical effects could be observed even with Si(Li) or SDD detectors. Such chemical effects can be clearly seen with high resolution crystal X-ray spectrometers having energy resolution of several eV. A dedicated vacuum chamber, housing the diffraction crystal, sample holder and CCD X-ray detector, was constructed and positioned behind the main ion microprobe vacuum chamber. Here we will briefly describe the spectrometer, and illustrate its capabilities on measured K X-ray spectra of selected sulfur compounds. We will also demonstrate its abilities to resolve K and M X-ray lines irresolvable by solid state ED detectors usually used in PIXE.

  18. Design considerations for an x-ray microprobe

    International Nuclear Information System (INIS)

    Howells, M.R.; Hastings, J.B.

    1982-01-01

    The optical design of a fluorescent microprobe covering the x-ray region from 2 to 16 keV is considered for the NSLS x-ray ring. The limit on detectability is from total flux (photons/μm 2 ) and several design choices are considered to match the optical system to the storage ring to maximize throughput. The tradeoffs in image quality and energy resolution of these designs have been considered and within these constraints two firm proposals are presented

  19. High resolution spectroscopy in solids by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Bonagamba, T.J.

    1991-07-01

    The nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids are described. Also the construction project of a partially home made spectrometer and its applications in the characterization of solid samples are shown in detail. The high resolution spectrometer used is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5 Khz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120 0 C to +160 0 C, and is fully controlled by a Macintosh IIci microcomputer. (author)

  20. High-resolution nuclear magnetic resonance studies of proteins.

    Science.gov (United States)

    Jonas, Jiri

    2002-03-25

    The combination of advanced high-resolution nuclear magnetic resonance (NMR) techniques with high-pressure capability represents a powerful experimental tool in studies of protein folding. This review is organized as follows: after a general introduction of high-pressure, high-resolution NMR spectroscopy of proteins, the experimental part deals with instrumentation. The main section of the review is devoted to NMR studies of reversible pressure unfolding of proteins with special emphasis on pressure-assisted cold denaturation and the detection of folding intermediates. Recent studies investigating local perturbations in proteins and the experiments following the effects of point mutations on pressure stability of proteins are also discussed. Ribonuclease A, lysozyme, ubiquitin, apomyoglobin, alpha-lactalbumin and troponin C were the model proteins investigated.

  1. Installation and performance of the Budapest-Hamburg proton microprobe

    International Nuclear Information System (INIS)

    Kovacs, I.; Kocsonya, A.; Kostka, P.; Szokefalvi-Nagy, Z.; Schrang, K.; Krueger, A.; Niecke, M.

    2005-01-01

    A new scanning proton microprobe has been installed at the 5 MV Van de Graaff accelerator of the KFKI Research Institute for Particle and Nuclear Physics. It is the energy-upgraded version of the Hamburg proton microprobe dismantled in 2001. The probe forming system includes a pair of focusing quadrupoles and an additional quadrupole pair in front of it, which is applied to increase the proton beam divergence. The average probe size at 2.5 MeV proton energy is 2.2 μm x 1.1 μm. The test results on stability and the preliminary experiments on cement corrosion and fish otoliths are also presented

  2. Mapping of trace elements with photon microprobes: x-ray fluorescence with focussed synchrotron radiation

    International Nuclear Information System (INIS)

    Hanson, A.L.; Jones, K.W.; Gordon, B.M.; Pounds, J.G.; Rivers, M.L.; Schidlovsky, G.

    1985-04-01

    High energy electron synchrotron storage rings provide copious quantities of polarized photons that make possible the mapping of many trace elements with sensitivities at the parts per billion (ppB) level with spatial resolutions in the micrometer range. The brightness of the x-ray ring of the National Synchrotron Light Source (NSLS), presently being commissioned, will be five orders of magnitude larger than that of the bremsstrahlung spectrum of state-of-the-art rotating anode tubes. We will discuss mapping trace elements with a photon microprobe presently being constructed for use at the NSLS. This microprobe will have micrometer spatial resolution

  3. Narrow nuclear resonance profiling of Al with subnanometric depth resolution

    International Nuclear Information System (INIS)

    Rosa, E.B.O. da; Krug, C.; Stedile, F.C.; Morais, J.; Baumvol, I.J.R.

    2002-01-01

    We report on the use of the narrow and isolated resonance at 404.9 keV in the cross-section curve of the 27 Al(p,γ) 28 Si nuclear reaction for profiling Al in ultrathin aluminum oxide films on Si. The samples were characterized as-deposited and after thermal annealing, so that Al transport could be studied. An estimated depth resolution of approximately 0.4 nm near the surface of the films could be obtained owing to: (i) the very small resonance width; (ii) the high stopping power of Al 2 O 3 for 404.9 keV protons; (iii) the high energy stability of the proton beam provided by the 500 kV HVEE ion implanter at Porto Alegre; and (iv) an apparent thickness magnification by a factor between 2.0 and 2.4 with the use of glancing incidence. This technique is compared to other methods for Al profiling like medium energy ion scattering and some sputtering-based techniques

  4. Proton microprobe analysis of zinc in skeletal tissues

    International Nuclear Information System (INIS)

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1981-01-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton micorprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage. (orig.)

  5. Enhancements to the analytical facilities at the GNS proton microprobe

    International Nuclear Information System (INIS)

    Barry, B.J.; Markwitz, A.; Kennedy, V.J.; Trompetter, W.J.

    2005-01-01

    In recent years a number of detection systems have been added to the proton microprobe facility at GNS Science. Particular additions have been a large area HPGe detector and a system for scanning transmission imaging microscopy. The HPGe detector has improved detection sensitivity, particularly for higher energy K x-rays where energy resolution is of lesser importance. The scanning microscopy system has enabled mapping of areal densities in biological samples to give accurate elemental maps. Examples are given of these applications. (author). 22 refs., 7 figs

  6. Resolution Improvement in Multidimensional Nuclear Magnetic Resonance Spectroscopy of Proteins

    International Nuclear Information System (INIS)

    Duma, L.

    2004-01-01

    The work presented in this thesis is concerned with both liquid-state and solid-state nuclear magnetic resonance (NMR) spectroscopy. Most of this work is devoted to the investigation by solid-state NMR of C 13 -enriched compounds with the principal aim of presenting techniques devised for further improving the spectral resolution in multidimensional NMR of microcrystalline proteins. In fully C 13 -labelled compounds, the J-coupling induces a broadening of the carbon lineshapes. We show that spin-state-selective technique called IPAP can be successfully combined with standard polarisation transfer schemes in order to remove the J-broadening in multidimensional solid-state NMR correlation experiments of fully C 13 -enriched proteins. We present subsequently two techniques tailored for liquid-state NMR spectroscopy. The carbon directly detected techniques provide chemical shift information for all backbone hetero-nuclei. They are very attracting for the study of large bio-molecular systems or for the investigation of paramagnetic proteins. In the last part of this thesis, we study the spin-echo J-modulation for homonuclear two-spin 1/2 systems. Under magic-angle spinning, the theory of J-induced spin-echo modulation allows to derive a set of modulation regimes which give a spin-echo modulation exactly equal to the J-coupling. We show that the chemical-shift anisotropy and the dipolar interaction tend to stabilize the spin-echo J-modulation. The theoretical conclusions are supported by numerical simulations and experimental results obtained for three representative samples containing C 13 spin pairs. (author)

  7. A novel technique for producing antibody-coated microprobes using a thiol-terminal silane and a heterobifunctional crosslinker.

    Science.gov (United States)

    Routh, V H; Helke, C J

    1997-02-01

    Antibody-coated microprobes are used to measure neuropeptide release in the central nervous system. Although they are not quantitative, they provide the most precise spatial resolution of the location of in vivo release of any currently available method. Previous methods of coating antibody microprobes are difficult and time-consuming. Moreover, using these methods we were unable to produce evenly coated antibody microprobes. This paper describes a novel method for the production of antibody microprobes using thiol-terminal silanes and the heterobifunctional crosslinker, 4-(4-N-maleimidophenyl)butyric acid hydrazide HCl 1/2 dioxane (MPBH). Following silation, glass micropipettes are incubated with antibody to substance P (SP) that has been conjugated to MPBH. This method results in a dense, even coating of antibody without decreasing the biological activity of the antibody. Additionally, this method takes considerably less time than previously described methods without sacrificing the use of antibody microprobes as micropipettes. The sensitivity of the microprobes for SP is in the picomolar range, and there is a linear correlation between the log of SP concentration (M) and B/B0 (r2 = 0.98). The microprobes are stable for up to 3 weeks when stored in 0.1 M sodium phosphate buffer with 50 mM NaCl (pH 7.4) at 5 degrees C. Finally, insertion into the exposed spinal cord of an anesthetized rat for 15 min produces no damage to the antibody coating.

  8. Resolution of the neutron diffractometer of the Mexican Nuclear Center

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Ita T, A. De

    2003-01-01

    The neutron diffractometer has three collimators and a monochromator of which it depends the resolution of the same one and exists a commitment between the resolution of the diffractometer and its intensity; if it is sought to work with more resolution, the intensity will diminish, and also, if one has little volume of the material, the diffracted light it is diminished, so the selection of the values of the collimators is this way important to have an unique value of the resolution of the diffractometer. (Author)

  9. Proton microprobe analysis of zinc in skeletal tissues. [Proton induced x-ray emission analysis

    Energy Technology Data Exchange (ETDEWEB)

    Doty, S B; Jones, K W; Kraner, H W; Shroy, R E; Hanson, A L

    1980-06-01

    A proton microprobe with windowless exit port was used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage.

  10. Beam optics on the Melbourne proton microprobe

    International Nuclear Information System (INIS)

    Jamieson, D.N.; Colman, R.A.; Allan, G.L.; Legge, G.J.F.

    1985-01-01

    This review paper summarises results of ion optics development work conducted on the Melbourne Proton Microprobe and the associated Pelletron accelerator. The properties of a field ionization ion source have been investigated with the aim of replacing the existing R.F. ion source in the accelerator in order to obtain a brighter beam for the microprobe. The electrostatic emitter lens in the terminal of the accelerator has also been investigated with the aim of improving the focus of the accelerated beam. Finally, the aberrations of the probe forming lens system have been studied and it is shown how some of these may be corrected with an octupole lens

  11. Data acquisition for X ray microprobe. User's manual

    International Nuclear Information System (INIS)

    2002-01-01

    A modified data acquisition software for X ray microprobe was developed by the Physics Group, Instrumentation Unit, IAEA Laboratories at Seibersdorf, with assistance from M. Bogovac, Croatia. The software consists of data acquisition (scanning and calibration), automatic positioning and micro-movement of sample, data reduction and evaluation. The acquisition software was designed in order to support different measurement set-ups which are applied in low-energy nuclear physics. The modification was done in 1999-2000 under the projects Nuclear Spectrometry and Utilization of Particle Accelerators. The manual supersedes the first version entitled Microanalysis Data Acquisition and Control Program published under Computer Manual Series, No. 9 in 1996. The software described in this manual is freely available from the IAEA upon request

  12. Microprobe analysis of teeth by synchrotron radiation: environmental contamination

    International Nuclear Information System (INIS)

    Pinheiro, T.; Carvalho, M.L.; Casaca, C.; Barreiros, M.A.; Cunha, A.S.; Chevallier, P.

    1999-01-01

    An X-ray fluorescence set-up with microprobe capabilities, installed at the Laboratoire pour l'Utilisation du Rayonnement Electromagnetique (LURE) synchrotron (France) was used for elemental determination in teeth. To evaluate the influence of living habits in dental elemental composition nine teeth collected post-mortem were analysed, five from a miner and four from a fisherman. All teeth from the fisherman were healthy. From the miner some teeth were carious and one of them was filled with metallic amalgam. Teeth were sliced under the vertical plane and each slice was scanned from the root to the enamel for elemental profile determination. The synchrotron microprobe resolution was of 100 μm and incident photons of 18 keV energy were used. The elemental concentration values found suggest heterogeneity of the teeth material. Moreover, the distinct profiles for Mn, Sr, Br and Pb were found when teeth from the miner and from the fisherman are compared which can be associated with dietary habits and environmental influence. Higher concentrations of Mn and Sr were found for the fisherman teeth. In addition, Br was only observed in this group of teeth. Pb levels are higher for the miner teeth in particular for dentine regions. The influence of amalgam, such as, increase of Zn and Hg contents in the teeth material, is only noticed for the immediate surroundings of the treated cavity

  13. Microstructural characterization of nuclear-waste ceramics

    International Nuclear Information System (INIS)

    Ryerson, F.J.; Clarke, D.R.

    1982-01-01

    Characterization of nuclear waste ceramics requires techniques possessing high spatial and x-ray resolution. XRD, SEM, electron microprobe, TEM and analytical EM techniques are applied to ceramic formulations designed to immobilize both commercial and defense-related reactor wastes. These materials are used to address the strengths and limitations of the techniques above. An iterative approach combining all these techniques is suggested. 16 figures, 2 tables

  14. Nuclear techniques for bulk and surface analysis of materials

    International Nuclear Information System (INIS)

    D'Agostino, M.D.; Kamykowski, E.A.; Kuehne, F.J.; Padawer, G.M.; Schneid, E.J.; Schulte, R.L.; Stauber, M.C.; Swanson, F.R.

    1978-01-01

    A review is presented summarizing several nondestructive bulk and surface analysis nuclear techniques developed in the Grumman Research Laboratories. Bulk analysis techniques include 14-MeV-neutron activation analysis and accelerator-based neutron radiography. The surface analysis techniques include resonant and non-resonant nuclear microprobes for the depth profile analysis of light elements (H, He, Li, Be, C, N, O and F) in the surface of materials. Emphasis is placed on the description and discussion of the unique nuclear microprobe analytical capacibilities of immediate importance to a number of current problems facing materials specialists. The resolution and contrast of neutron radiography was illustrated with an operating heat pipe system. The figure shows that the neutron radiograph has a resolution of better than 0.04 cm with sufficient contrast to indicate Freon 21 on the inner capillaries of the heat pipe and pooling of the liquid at the bottom. (T.G.)

  15. Noise and resolution with digital filtering for nuclear spectrometry

    International Nuclear Information System (INIS)

    Lakatos, T.

    1991-01-01

    Digital noise filtering looks very promising for semiconductor spectrometry. The resolution and conversion speed of the analog to digital converter (ADC) used at the input of a digital signal processor and analyzer can strongly influence the signal to noise ratio, the peak position and shape. The article leads with the investigation of these effects using computer modelling. (orig.)

  16. Quantitative optical fluorescence microprobe measurements of stresses around indentations in Al2O3 and Al2O3/SiC nanocomposites: The influence of depth resolution and specimen translucency

    International Nuclear Information System (INIS)

    Guo Sheng; Todd, R.I.

    2011-01-01

    Residual stresses around 1 kg Vickers indentations in Al 2 O 3 and Al 2 O 3 /SiC nanocomposites were measured using high-resolution Cr 3+ fluorescence microscopy. Experiments and modelling showed that the use of non-confocal microscopes can lead to significant underestimation of the surface stress in Al 2 O 3 because of the sampling of subsurface regions where the stresses are lower. The nanocomposites were less sensitive to the depth resolution of the microscope because their strong absorption limited the depth from which fluorescent radiation was collected. The use of confocal microscope settings allowed accurate measurements to be made and the indentation stresses were found to be very similar in Al 2 O 3 and the Al 2 O 3 /SiC nanocomposites. The stresses measured were significantly different from the predictions of the Yoffe model for indentation stresses. This was because of indentation cracking, which is not accounted for in the model. Cracking was also considered to be important in determining the plastic zone size in ceramics, which is much smaller relative to the indentation size than in metals.

  17. A high resolution gridded ionization chamber for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Vitale, E.R.

    1988-01-01

    This paper describes some techniques used in the design of high resolution gridded ionisation chambers for measurements of absolute activity of radionuclides. Details of the geometry of the system and its electrodes are presented; their shape and the spacing between the grid wire was studied with the help of an electrolytic tank. The experimental spectra obtained with an Am 241 source using Ar + 10% methane as a flow gas show a total resolution of 39,07 KeV in very good agreement with the best results available in the literature. An application of the methods developed was used in the design ans construction of a proportional counter provided with three sequential grids disposed in such a way that the pulses from the first stage had their amplitude multiplied by the two further stages. Multiplication factors of the order of 10 sup(3) were obtained but higher values are expected. (author)

  18. Resolution of alarms for loss of bulk nuclear material

    International Nuclear Information System (INIS)

    Eggers, R.F.; Davenport, L.C.

    1982-01-01

    Under methods of material accountability considered in the NRC's Reform Amendment (Federal Register, 46(175):45144 to 45151 dated September 10, 1981) prompt detection of losses and resolution of alarms play a central role in the day-to-day activities of the Material Control and Accounting (MC and A) System. This paper will discuss the two basic pathways of alarm resolution, namely, verification of the magnitude of the loss indicated by the initial alarm, and detection of deliberate or accidental accounting discrepancies. Progress along these pathways leads to a consensus that either (1) a loss occurred, (2) the original alarm was caused by MC and A error, or (3) the cause of the original alarm is uncertain. Three phases of response will be outlined and an example of response to alarms will be given for a mixed oxide powder processing control unit

  19. PIXE macro and microprobe techniques in archaeometry

    International Nuclear Information System (INIS)

    Brissaud, I.; Lagarde, G.; Houdayer, A.

    1987-01-01

    PIXE analysis method is applied to archaeometry problems. Advantages and disadvantages are emphasized. Some examples are presented which show the difficulties: especially important heterogeneities of ceramics, old coins and metals restrain from the use of this technique. Other analysis systems, less expensive, like electron microbrobe or x-ray fluorescence spectrometry, are compared with conventional PIXE method. The importance of proton microprobe is explained. (author) 40 refs.; 7 figs.; 5 tabs

  20. High-Resolution Imaging Reveals New Features of Nuclear Export of mRNA through the Nuclear Pore Complexes

    Directory of Open Access Journals (Sweden)

    Joseph M. Kelich

    2014-08-01

    Full Text Available The nuclear envelope (NE of eukaryotic cells provides a physical barrier for messenger RNA (mRNA and the associated proteins (mRNPs traveling from sites of transcription in the nucleus to locations of translation processing in the cytoplasm. Nuclear pore complexes (NPCs embedded in the NE serve as a dominant gateway for nuclear export of mRNA. However, the fundamental characterization of export dynamics of mRNPs through the NPC has been hindered by several technical limits. First, the size of NPC that is barely below the diffraction limit of conventional light microscopy requires a super-resolution microscopy imaging approach. Next, the fast transit of mRNPs through the NPC further demands a high temporal resolution by the imaging approach. Finally, the inherent three-dimensional (3D movements of mRNPs through the NPC demand the method to provide a 3D mapping of both transport kinetics and transport pathways of mRNPs. This review will highlight the recently developed super-resolution imaging techniques advanced from 1D to 3D for nuclear export of mRNPs and summarize the new features in the dynamic nuclear export process of mRNPs revealed from these technical advances.

  1. Resolution no. 15/2012 Safety Guide for the practice of nuclear meters

    International Nuclear Information System (INIS)

    2012-01-01

    1. This guide is Intended to complement the requirements for practice Nuclear meters out in September: • Joint Resolution CITMA-MINSAP Regulation Basic Standards Radiation safety of November 30, 2001, hereinafter NBS. • CITMA Resolution 121/2000, Regulations for the Safe Transport Radioactive Materials; hereinafter transport regulations. • Resolution 35/2003 of CITMA Regulation for the safe management of Radioactive waste of March 7, 2003, hereinafter Regulation waste. • Joint Resolution CITMA-MINSAP Regulations for the Selection, Training Authorization and Associated Personnel performing Employment Practices of Ionizing Radiation of December 19, 2003, hereinafter Staff Rules. 2. The requirements of this guide are applicable to entities and performing practice-related activities Nuclear Meters throughout the national territory.

  2. Milliprobe and microprobe analysis of gold items of ancient jewellery

    International Nuclear Information System (INIS)

    Demortier, G.; Hackens, T.

    It has long been accepted that the presence of cadmium implies a condemnation of the authenticity of an ancient gold object, or at least, of the part of the object where the cadmium is detected. An analysis in Paris of a recently excavated object from Roman times has shown cadmium. Meanwhile, systematic observations were made at L.A.R.N. on objects dating from Hellenistic to Byzantine times with different given origins (objects from a museum and from private collections). By using PIXE with a 3 MeV proton milliprobe (700 μm beam diameter) in a non vacuum geometry, relative amounts of copper, silver, cadmium and gold at the surface of more than 30 gold objects expected to be ancient have been determined. Traces or significant concentrations of cadmium have been detected at several points on or in the neighbourhood of solders on many objects which seem to be from Roman to early Byzantine times. Cadmium concentrations range between 2 to 100 parts per thousand. This range of variations and the relative concentrations of Au, Ag, Cu and Cd at the surface of the objects studied are often different from the figures obtained during analyses of modern soldering alloys. Experiments with the L.A.R.N. proton microprobe (5 μm x 10 μm area) allow a still better topographical resolution and more significative comparison of the relative amounts of the elements of interest in modern soldering alloys and supposedly old solders. The usefulness of the microprobe is demonstrated. (author)

  3. Electron microprobe analysis of tantalum--nitride thin films

    International Nuclear Information System (INIS)

    Stoltz, D.L.; Starkey, J.P.

    1979-06-01

    Quantitative chemical analysis of 500- and 2000-angstrom tantalum--nitride films on glass substrates has been accomplished using an electron microprobe x-ray analyzer. In order to achieve this analysis, modifications to the microprobe were necessary. A description of the calibration procedure, the method of analysis, and the quantitative results are discussed

  4. Nuclear charge radii and nuclear moments of neutron deficient Ba isotopes from high resolution laser spectroscopy

    International Nuclear Information System (INIS)

    Nowicki, G.; Bekk, K.; Goering, S.; Hanser, A.; Rebel, H.; Schatz, G.

    1978-07-01

    Isotope shifts and hyperfine structure of the BaI 6s 2 1 S 0 -6s6p 1 P 1 transitions (lambda = 553.6 nm) in neutron deficient Ba nuclides (N 131 Ba, 128 Ba, in addition to remeasurements of all stable Ba nuclides. The extracted values of delta 2 >, the observed odd-even staggering and the nuclear moments are discussed in the light of other theoretical and experimental nuclear structure studies of the region 50 [de

  5. North Korea’s Second Nuclear Test: Implications of U.N. Security Council Resolution 1874

    Science.gov (United States)

    2010-04-15

    butter” (or in North Korea’s case, rice ) and, in the process, creating a humanitarian disaster. The additional sanctions in U.N. Resolution 1874 target...the May 2009 North Korean nuclear test. See also CRS Report RL34327, Proliferation Security Initiative (PSI), by Mary Beth Nikitin. 72 “Nuclear Black ...Beverages 5,137,988 5,084,449 6,652,041 33 Perfumery, Cosmetic Products 1,322,454 1,672,327 1,688,481 42 Leather Art; Saddlery, Etc. 772,645 1,441,805

  6. New 2-stage ion microprobes and a move to higher energies

    Energy Technology Data Exchange (ETDEWEB)

    Legge, G.J.F.; Dymnikov, A.; Moloney, G.; Saint, A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Cohen, D. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Recent moves in Ion Beam Microanalysis towards the use of a rapidly growing number of very high resolution, low current and single ion techniques has led to the need for high demagnification and greatly improved beam quality. There is also a move to apply Microbeams at higher energies and with heavier ions. This also puts demands on the focusing system and beam control. This paper describes the recent development of 2-stage lens systems to be applied here and overseas, both at very high resolution and at high energies with heavy ions. It looks at new ion beam analysis applications of such ion microprobes. 8 refs., 1 tab., 1 fig.

  7. New 2-stage ion microprobes and a move to higher energies

    Energy Technology Data Exchange (ETDEWEB)

    Legge, G J.F.; Dymnikov, A; Moloney, G; Saint, A [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Cohen, D [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Recent moves in Ion Beam Microanalysis towards the use of a rapidly growing number of very high resolution, low current and single ion techniques has led to the need for high demagnification and greatly improved beam quality. There is also a move to apply Microbeams at higher energies and with heavier ions. This also puts demands on the focusing system and beam control. This paper describes the recent development of 2-stage lens systems to be applied here and overseas, both at very high resolution and at high energies with heavy ions. It looks at new ion beam analysis applications of such ion microprobes. 8 refs., 1 tab., 1 fig.

  8. Line broadening interference for high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

    International Nuclear Information System (INIS)

    Wei, Zhiliang; Yang, Jian; Lin, Yanqin; Chen, Zhong; Chen, Youhe

    2015-01-01

    Nuclear magnetic resonance spectroscopy serves as an important tool for analyzing chemicals and biological metabolites. However, its performance is subject to the magnetic-field homogeneity. Under inhomogeneous fields, peaks are broadened to overlap each other, introducing difficulties for assignments. Here, we propose a method termed as line broadening interference (LBI) to provide high-resolution information under inhomogeneous magnetic fields by employing certain gradients in the indirect dimension to interfere the magnetic-field inhomogeneity. The conventional spectral-line broadening is thus interfered to be non-diagonal, avoiding the overlapping among adjacent resonances. Furthermore, an inhomogeneity correction algorithm is developed based on pattern recognition to recover the high-resolution information from LBI spectra. Theoretical deductions are performed to offer systematic and detailed analyses on the proposed method. Moreover, experiments are conducted to prove the feasibility of the proposed method for yielding high-resolution spectra in inhomogeneous magnetic fields

  9. High resolution spectroscopy in solids by nuclear magnetic resonance; Espectroscopia de alta resolucao em solidos por ressonancia magnetica nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Bonagamba, T J

    1991-07-01

    The nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids are described. Also the construction project of a partially home made spectrometer and its applications in the characterization of solid samples are shown in detail. The high resolution spectrometer used is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5 Khz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -120{sup 0} C to +160{sup 0} C, and is fully controlled by a Macintosh IIci microcomputer. (author).

  10. Angstrom-Resolution Magnetic Resonance Imaging of Single Molecules via Wave-Function Fingerprints of Nuclear Spins

    Science.gov (United States)

    Ma, Wen-Long; Liu, Ren-Bao

    2016-08-01

    Single-molecule sensitivity of nuclear magnetic resonance (NMR) and angstrom resolution of magnetic resonance imaging (MRI) are the highest challenges in magnetic microscopy. Recent development in dynamical-decoupling- (DD) enhanced diamond quantum sensing has enabled single-nucleus NMR and nanoscale NMR. Similar to conventional NMR and MRI, current DD-based quantum sensing utilizes the "frequency fingerprints" of target nuclear spins. The frequency fingerprints by their nature cannot resolve different nuclear spins that have the same noise frequency or differentiate different types of correlations in nuclear-spin clusters, which limit the resolution of single-molecule MRI. Here we show that this limitation can be overcome by using "wave-function fingerprints" of target nuclear spins, which is much more sensitive than the frequency fingerprints to the weak hyperfine interaction between the targets and a sensor under resonant DD control. We demonstrate a scheme of angstrom-resolution MRI that is capable of counting and individually localizing single nuclear spins of the same frequency and characterizing the correlations in nuclear-spin clusters. A nitrogen-vacancy-center spin sensor near a diamond surface, provided that the coherence time is improved by surface engineering in the near future, may be employed to determine with angstrom resolution the positions and conformation of single molecules that are isotope labeled. The scheme in this work offers an approach to breaking the resolution limit set by the "frequency gradients" in conventional MRI and to reaching the angstrom-scale resolution.

  11. U and Pb isotope analysis of uraninite and galena by ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Evins, L.Z.; Sunde, T.; Schoeberg, H. [Swedish Museum of Natural History, Stockholm (Sweden). Laboratory for Isotope Geology; Fayek, M. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Geological Sciences

    2001-10-01

    Accurate isotopic analysis of minerals by ion microprobe, or SIMS (Secondary Ion Mass Spectrometry) usually requires a standard to correct for instrumental mass bias effects that occur during analysis. We have calibrated two uraninite crystals and one galena crystal to be used as ion probe standards. As part of this study we describe the analytical procedures and problems encountered while trying to establish fractionation factors for U and Pb isotopes measured in galena and uraninite. Only the intra-element isotopic mass fractionation is considered and not the interelement fractionation. Galena and uraninite were analysed with TIMS (Thermal Ionisation Mass Spectrometry) prior to SIMS. One uraninite crystal (P88) comes from Sweden and is ca 900 Ma old, the other from Maine, USA (LAMNH-30222) and is ca 350 Ma old. The galena sample comes from the Paleoproterozoic ore district Bergslagen in Sweden. SIMS analyses were performed at two different laboratories: the NORDSM facility in Stockholm, which has a high resolution Cameca IMS 1270 ion microprobe, and the Oak Ridge National Laboratory (ORNL) in Tennessee, which has a Cameca IMS 4f ion microprobe. The results show that during the analysis of galena, Pb isotopes fractionate in favour of the lighter isotope by as much as 0.5%/amu. A Pb isotope fractionation factor for uraninite was more difficult to calculate, probably due to the formation of hydride interferences encountered during analysis with the Cameca IMS 1270 ion microprobe. However, drying the sample in vacuum prior to analysis, and using high-energy filtering and a cold trap during analysis can minimise these hydride interferences. A large fractionation of U isotopes of ca 1.4%/amu in favour of the lighter isotope was calculated for uraninite.

  12. U and Pb isotope analysis of uraninite and galena by ion microprobe

    International Nuclear Information System (INIS)

    Evins, L.Z.; Sunde, T.; Schoeberg, H.; Fayek, M.

    2001-10-01

    Accurate isotopic analysis of minerals by ion microprobe, or SIMS (Secondary Ion Mass Spectrometry) usually requires a standard to correct for instrumental mass bias effects that occur during analysis. We have calibrated two uraninite crystals and one galena crystal to be used as ion probe standards. As part of this study we describe the analytical procedures and problems encountered while trying to establish fractionation factors for U and Pb isotopes measured in galena and uraninite. Only the intra-element isotopic mass fractionation is considered and not the interelement fractionation. Galena and uraninite were analysed with TIMS (Thermal Ionisation Mass Spectrometry) prior to SIMS. One uraninite crystal (P88) comes from Sweden and is ca 900 Ma old, the other from Maine, USA (LAMNH-30222) and is ca 350 Ma old. The galena sample comes from the Paleoproterozoic ore district Bergslagen in Sweden. SIMS analyses were performed at two different laboratories: the NORDSM facility in Stockholm, which has a high resolution Cameca IMS 1270 ion microprobe, and the Oak Ridge National Laboratory (ORNL) in Tennessee, which has a Cameca IMS 4f ion microprobe. The results show that during the analysis of galena, Pb isotopes fractionate in favour of the lighter isotope by as much as 0.5%/amu. A Pb isotope fractionation factor for uraninite was more difficult to calculate, probably due to the formation of hydride interferences encountered during analysis with the Cameca IMS 1270 ion microprobe. However, drying the sample in vacuum prior to analysis, and using high-energy filtering and a cold trap during analysis can minimise these hydride interferences. A large fractionation of U isotopes of ca 1.4%/amu in favour of the lighter isotope was calculated for uraninite

  13. Nuclear waste disposal: Can there be a resolution? Past problems and future solutions

    Energy Technology Data Exchange (ETDEWEB)

    Ahearne, J [Scientific Research Society, Sigma Xi, Research Triangle Park, NC (United States)

    1990-07-01

    Why does the high level waste problem have to be solved now? There are perhaps three answers to that question. First, to have a recovery of nuclear power. But a lack of resolution of the high level waste problem is not the principal reason that nuclear power has foundered and, consequently, solving it will not automatically revive nuclear power. However, if the nuclear industry is adamantly convinced that this is the key to reviving nuclear power, then the nuclear industry should demonstrate its conviction by putting much greater effort into resolving the high level waste problem technically, not through public relations. For example, a substantial effort on the actinide burning approach might demonstrate, in the old American phrase, 'putting your money where your mouth is'. Second, the high level waste problem must be solved now because it is a devil's brew. However, chemical wastes last longer, as we all know, than do the radioactive wastes. As one expert has noted: 'There is real risk in nuclear power, just as there is real risk in coal power.... For some of [these risks], like the greenhouse effect, the potential damage is devastating. While for others, like nuclear accidents, the risk is limited, but imaginations are not. For still others, like the risk posed by a high-level waste repository, there is essentially nothing outside the imagination of the gullible.' Furthermore, any technical solution or any solution to a risky problem requires one to think carefully. It is often better to do it right than quickly. A third reason for requiring it to be solved right now is that HLW disposal is a major technical problem blocking a potentially valuable energy source. But we need a new solution. The current solutions are not working. I believe that we ought to recognize the failure of the geologic repository approach. I believe the federal government should identify, with industry's assistance, the best techniques for surface storage. Some federal locations should be

  14. Nuclear waste disposal: Can there be a resolution? Past problems and future solutions

    International Nuclear Information System (INIS)

    Ahearne, J.

    1990-01-01

    Why does the high level waste problem have to be solved now? There are perhaps three answers to that question. First, to have a recovery of nuclear power. But a lack of resolution of the high level waste problem is not the principal reason that nuclear power has foundered and, consequently, solving it will not automatically revive nuclear power. However, if the nuclear industry is adamantly convinced that this is the key to reviving nuclear power, then the nuclear industry should demonstrate its conviction by putting much greater effort into resolving the high level waste problem technically, not through public relations. For example, a substantial effort on the actinide burning approach might demonstrate, in the old American phrase, 'putting your money where your mouth is'. Second, the high level waste problem must be solved now because it is a devil's brew. However, chemical wastes last longer, as we all know, than do the radioactive wastes. As one expert has noted: 'There is real risk in nuclear power, just as there is real risk in coal power.... For some of [these risks], like the greenhouse effect, the potential damage is devastating. While for others, like nuclear accidents, the risk is limited, but imaginations are not. For still others, like the risk posed by a high-level waste repository, there is essentially nothing outside the imagination of the gullible.' Furthermore, any technical solution or any solution to a risky problem requires one to think carefully. It is often better to do it right than quickly. A third reason for requiring it to be solved right now is that HLW disposal is a major technical problem blocking a potentially valuable energy source. But we need a new solution. The current solutions are not working. I believe that we ought to recognize the failure of the geologic repository approach. I believe the federal government should identify, with industry's assistance, the best techniques for surface storage. Some federal locations should be

  15. Sun, Ocean, Nuclear Bombs, and Fossil Fuels: Radiocarbon Variations and Implications for High-Resolution Dating

    Science.gov (United States)

    Dutta, Koushik

    2016-06-01

    Radiocarbon, or 14C, is a radiometric dating method ideally suited for providing a chronological framework in archaeology and geosciences for timescales spanning the last 50,000 years. 14C is easily detectable in most common natural organic materials and has a half-life (5,730±40 years) relevant to these timescales. 14C produced from large-scale detonations of nuclear bombs between the 1950s and the early 1960s can be used for dating modern organic materials formed after the 1950s. Often these studies demand high-resolution chronology to resolve ages within a few decades to less than a few years. Despite developments in modern, high-precision 14C analytical methods, the applicability of 14C in high-resolution chronology is limited by short-term variations in atmospheric 14C in the past. This article reviews the roles of the principal natural drivers (e.g., solar magnetic activity and ocean circulation) and the anthropogenic perturbations (e.g., fossil fuel CO2 and 14C from nuclear and thermonuclear bombs) that are responsible for short-term 14C variations in the environment. Methods and challenges of high-resolution 14C dating are discussed.

  16. Contribution to the resolution of algebraic differential equations. Application to electronic circuits and nuclear reactors

    International Nuclear Information System (INIS)

    Monsef, Youssef.

    1977-05-01

    This note deals with the resolution of large algebraic differential systems involved in the physical sciences, with special reference to electronics and nuclear physics. The theoretical aspect of the algorithms established and developed for this purpose is discussed in detail. A decomposition algorithm based on the graph theory is developed in detail and the regressive analysis of the error involved in the decomposition is carried out. The specific application of these algorithms on the analyses of non-linear electronic circuits and to the integration of algebraic differential equations simulating the general operation of nuclear reactors coupled to heat exchangers is discussed in detail. To conclude, it is shown that the development of efficient digital resolution techniques dealing with the elements in order is sub-optimal for large systems and calls for the revision of conventional formulation methods. Thus for a high-order physical system, the larger, the number of auxiliary unknowns introduced, the easier the formulation and resolution, owing to the elimination of any form of complex matricial calculation such as those given by the state variables method [fr

  17. Elemental microanalysis of botanical specimens using the Melbourne Proton Microprobe

    International Nuclear Information System (INIS)

    Mazzolini, A.P.J.; Legge, G.J.F.

    1978-01-01

    A proton microprobe has been used to obtain the distribution of elements of various botanical specimens. This paper presents preliminary results obtained by the irradiation of certain organs of the wheat plant

  18. Deep Space 2: The Mars Microprobe Mission

    Science.gov (United States)

    Smrekar, Suzanne; Catling, David; Lorenz, Ralph; Magalhães, Julio; Moersch, Jeffrey; Morgan, Paul; Murray, Bruce; Presley-Holloway, Marsha; Yen, Albert; Zent, Aaron; Blaney, Diana

    The Mars Microprobe Mission will be the second of the New Millennium Program's technology development missions to planetary bodies. The mission consists of two penetrators that weigh 2.4 kg each and are being carried as a piggyback payload on the Mars Polar Lander cruise ring. The spacecraft arrive at Mars on December 3, 1999. The two identical penetrators will impact the surface at ~190 m/s and penetrate up to 0.6 m. They will land within 1 to 10 km of each other and ~50 km from the Polar Lander on the south polar layered terrain. The primary objective of the mission is to demonstrate technologies that will enable future science missions and, in particular, network science missions. A secondary goal is to acquire science data. A subsurface evolved water experiment and a thermal conductivity experiment will estimate the water content and thermal properties of the regolith. The atmospheric density, pressure, and temperature will be derived using descent deceleration data. Impact accelerometer data will be used to determine the depth of penetration, the hardness of the regolith, and the presence or absence of 10 cm scale layers.

  19. Ion microprobe analysis of metallic pigments

    International Nuclear Information System (INIS)

    Pelicon, P.; Simcic, J.; Budnar, M.; Klanjsek-Gunde, M.; Kunavaer, M.

    2001-01-01

    Full text: Metallic paints consist of metallic flakes dispersed m a resinous binder, i.e. a light-element polymer matrix. The spatial distribution and orientation of metallic flakes inside the matrix determines the covering efficiency of the paint, glossiness, and its angular-dependent properties such as lightness flop or color flop (two-tone). Such coatings are extensively used for a functional (i.e. security) as well as decorative purpose. The ion microbeam analysis of two types of silver paint with imbedded metallic flake has been performed to test the ability of the ion microbeam spectroscopic methods on this type of samples. The average sizes of the aluminium flakes were 23 (size distribution 10-37) and 49 (size distribution 34-75) micrometers, respectively. The proton beam with the size of 2x2 micrometers at Ljubljana ion microprobe has been used to scan the surface of the pigments. PIXE mapping of Al Kα map shows lateral distribution of the aluminum flakes, whereas the RBS slicing method reveals tomographic image of the flakes in uppermost 5 micrometers of the pigment layer. The flake distribution in the larger layer depths has been accessed by RBS analysis in a point mode. (author)

  20. Proton microprobe analysis of pancreatic. beta. cells

    Energy Technology Data Exchange (ETDEWEB)

    Lindh, U [Uppsala Univ. (Sweden). Gustaf Werner Inst.; Juntti-Berggren, L; Berggren, P O; Hellman, B [Uppsala Univ. (Sweden)

    1985-01-01

    Freeze-dried pancreas sections from obese hyperglycemic mice were subjected to proton bombardment and the elemental contents in the ..beta.. cells and the exocrine part were obtained from the characteristic X-rays emitted. Quantitative data were provided for 18 different elements. The mole ratio between K and Na exceeded 10, implying that neither the sample preparation nor the irradiation had induced significant diffuse changes. With the demonstration of this high K/Na ratio it seems likely that also the ..beta.. cells are equipped with an efficient Na/sup +//K/sup +/ pump. The ..beta.. cells contained about 70 mmoles Cl per litre cell water. Observed amounts of Ca and Mg were equivalent to those previously recorded by electrothermal atomic absorption spectroscopy. The significant role of Zn for the storage of insulin was emphasized by the demonstration of 3 times as much of this element in the ..beta.. cells as compared with the exocrine pancreas. In addition, the sensitivity of the proton microprobe enabled measurements of various trace elements such as Rb, Cr, Cu, Al and Pb not previously demonstrated in the pancreatic ..beta.. cells.

  1. Assessment of ambient-temperature, high-resolution detectors for nuclear safeguards applications

    International Nuclear Information System (INIS)

    Ruhter, W.D.; McQuaid, J.H.; Lavietes, A.

    1993-01-01

    High-resolution, gamma- and x-ray spectrometry are used routinely in nuclear safeguards verification measurements of plutonium and uranium in the field. These measurements are now performed with high-purity germanium (HPGe) detectors that require cooling liquid-nitrogen temperatures, thus limiting their utility in field and unattended safeguards measurement applications. Ambient temperature semiconductor detectors may complement HPGe detectors for certain safeguards verification applications. Their potential will be determined by criteria such as their performance, commercial availability, stage of development, and costs. We have conducted as assessment of ambient temperature detectors for safeguards measurement applications with these criteria in mind

  2. Resolution establishing the Preparatory Commission for the Comprehensive Nuclear Test-Ban Treaty Organization. Adopted on 19 November 1996

    International Nuclear Information System (INIS)

    1996-11-01

    The document reproduces the text of the Resolution on the Establishment of a Preparatory Commission for the Comprehensive Nuclear Test-Ban Treaty Organization which was adopted on 19 November 1996 at a meeting of the States Signatories of the Comprehensive Nuclear Test-Ban Treaty

  3. U/Th dating by SHRIMP RG ion-microprobe mass spectrometry using single ion-exchange beads

    Science.gov (United States)

    Bischoff, J.L.; Wooden, J.; Murphy, F.; Williams, Ross W.

    2005-01-01

    We present a new analytical method for U-series isotopes using the SHRIMP RG (Sensitive High mass Resolution Ion MicroProbe) mass spectrometer that utilizes the preconcentration of the U-series isotopes from a sample onto a single ion-exchange bead. Ion-microprobe mass spectrometry is capable of producing Th ionization efficiencies in excess of 2%. Analytical precision is typically better than alpha spectroscopy, but not as good as thermal ionization mass spectroscopy (TIMS) and inductively coupled plasma multicollector mass spectrometry (ICP-MS). Like TIMS and ICP-MS the method allows analysis of small samples sizes, but also adds the advantage of rapidity of analysis. A major advantage of ion-microprobe analysis is that U and Th isotopes are analyzed in the same bead, simplifying the process of chemical separation. Analytical time on the instrument is ???60 min per sample, and a single instrument-loading can accommodate 15-20 samples to be analyzed in a 24-h day. An additional advantage is that the method allows multiple reanalyses of the same bead and that samples can be archived for reanalysis at a later time. Because the ion beam excavates a pit only a few ??m deep, the mount can later be repolished and reanalyzed numerous times. The method described of preconcentrating a low concentration sample onto a small conductive substrate to allow ion-microprobe mass spectrometry is potentially applicable to many other systems. Copyright ?? 2005 Elsevier Ltd.

  4. ;Study of secondary hydriding at high temperature in zirconium based nuclear fuel cladding tubes by coupling information from neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and laser induced breakdown spectroscopy microprobe

    Science.gov (United States)

    Brachet, Jean-Christophe; Hamon, Didier; Le Saux, Matthieu; Vandenberghe, Valérie; Toffolon-Masclet, Caroline; Rouesne, Elodie; Urvoy, Stéphane; Béchade, Jean-Luc; Raepsaet, Caroline; Lacour, Jean-Luc; Bayon, Guy; Ott, Frédéric

    2017-05-01

    This paper gives an overview of a multi-scale experimental study of the secondary hydriding phenomena that can occur in nuclear fuel cladding materials exposed to steam at high temperature (HT) after having burst (loss-of-coolant accident conditions). By coupling information from several facilities, including neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and micro laser induced breakdown spectroscopy, it was possible to map quantitatively, at different scales, the distribution of oxygen and hydrogen within M5™ clad segments having experienced ballooning and burst at HT followed by steam oxidation at 1100 and 1200 °C and final direct water quenching down to room temperature. The results were very reproducible and it was confirmed that internal oxidation and secondary hydriding at HT of a cladding after burst can lead to strong axial and azimuthal gradients of hydrogen and oxygen concentrations, reaching 3000-4000 wt ppm and 1.0-1.2 wt% respectively within the β phase layer for the investigated conditions. Consistent with thermodynamic and kinetics considerations, oxygen diffusion into the prior-β layer was enhanced in the regions highly enriched in hydrogen, where the α(O) phase layer is thinner and the prior-β layer thicker. Finally the induced post-quenching hardening of the prior-β layer was mainly related to the local oxygen enrichment. Hardening directly induced by hydrogen was much less significant.

  5. Para-hydrogen raser delivers sub-millihertz resolution in nuclear magnetic resonance

    Science.gov (United States)

    Suefke, Martin; Lehmkuhl, Sören; Liebisch, Alexander; Blümich, Bernhard; Appelt, Stephan

    2017-06-01

    The precision of nuclear magnetic resonance spectroscopy (NMR) is limited by the signal-to-noise ratio, the measurement time Tm and the linewidth Δν = 1/(πT2). Overcoming the T 2 limit is possible if the nuclear spins of a molecule emit continuous radio waves. Lasers and masers are self-organized systems which emit coherent radiation in the optical and micro-wave regime. Both are based on creating a population inversion of specific energy states. Here we show continuous oscillations of proton spins of organic molecules in the radiofrequency regime (raser). We achieve this by coupling a population inversion created through signal amplification by reversible exchange (SABRE) to a high-quality-factor resonator. For the case of 15N labelled molecules, we observe multi-mode raser activity, which reports different spin quantum states. The corresponding 1H-15N J-coupled NMR spectra exhibit unprecedented sub-millihertz resolution and can be explained assuming two-spin ordered quantum states. Our findings demonstrate a substantial improvement in the frequency resolution of NMR.

  6. Adaptive multi-resolution 3D Hartree-Fock-Bogoliubov solver for nuclear structure

    Science.gov (United States)

    Pei, J. C.; Fann, G. I.; Harrison, R. J.; Nazarewicz, W.; Shi, Yue; Thornton, S.

    2014-08-01

    Background: Complex many-body systems, such as triaxial and reflection-asymmetric nuclei, weakly bound halo states, cluster configurations, nuclear fragments produced in heavy-ion fusion reactions, cold Fermi gases, and pasta phases in neutron star crust, are all characterized by large sizes and complex topologies in which many geometrical symmetries characteristic of ground-state configurations are broken. A tool of choice to study such complex forms of matter is an adaptive multi-resolution wavelet analysis. This method has generated much excitement since it provides a common framework linking many diversified methodologies across different fields, including signal processing, data compression, harmonic analysis and operator theory, fractals, and quantum field theory. Purpose: To describe complex superfluid many-fermion systems, we introduce an adaptive pseudospectral method for solving self-consistent equations of nuclear density functional theory in three dimensions, without symmetry restrictions. Methods: The numerical method is based on the multi-resolution and computational harmonic analysis techniques with a multi-wavelet basis. The application of state-of-the-art parallel programming techniques include sophisticated object-oriented templates which parse the high-level code into distributed parallel tasks with a multi-thread task queue scheduler for each multi-core node. The internode communications are asynchronous. The algorithm is variational and is capable of solving coupled complex-geometric systems of equations adaptively, with functional and boundary constraints, in a finite spatial domain of very large size, limited by existing parallel computer memory. For smooth functions, user-defined finite precision is guaranteed. Results: The new adaptive multi-resolution Hartree-Fock-Bogoliubov (HFB) solver madness-hfb is benchmarked against a two-dimensional coordinate-space solver hfb-ax that is based on the B-spline technique and a three-dimensional solver

  7. “Study of secondary hydriding at high temperature in zirconium based nuclear fuel cladding tubes by coupling information from neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and laser induced breakdown spectroscopy microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Brachet, Jean-Christophe, E-mail: jean-christophe.brachet@cea.fr [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Hamon, Didier; Le Saux, Matthieu [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Vandenberghe, Valérie [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); DEN-Service d’Etudes Mécaniques et Thermiques (SEMT), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Toffolon-Masclet, Caroline; Rouesne, Elodie; Urvoy, Stéphane [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Béchade, Jean-Luc [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); DEN-Service de Recherches de Métallurgie Physique (SRMP), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Raepsaet, Caroline [LEEL, CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); NIMBE, CEA, CNRS, Université Paris-Saclay, 91191 Gif-sur-Yvette Cedex (France); and others

    2017-05-15

    This paper gives an overview of a multi-scale experimental study of the secondary hydriding phenomena that can occur in nuclear fuel cladding materials exposed to steam at high temperature (HT) after having burst (loss-of-coolant accident conditions). By coupling information from several facilities, including neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and micro laser induced breakdown spectroscopy, it was possible to map quantitatively, at different scales, the distribution of oxygen and hydrogen within M5™ clad segments having experienced ballooning and burst at HT followed by steam oxidation at 1100 and 1200 °C and final direct water quenching down to room temperature. The results were very reproducible and it was confirmed that internal oxidation and secondary hydriding at HT of a cladding after burst can lead to strong axial and azimuthal gradients of hydrogen and oxygen concentrations, reaching 3000–4000 wt ppm and 1.0–1.2 wt% respectively within the β phase layer for the investigated conditions. Consistent with thermodynamic and kinetics considerations, oxygen diffusion into the prior-β layer was enhanced in the regions highly enriched in hydrogen, where the α(O) phase layer is thinner and the prior-β layer thicker. Finally the induced post-quenching hardening of the prior-β layer was mainly related to the local oxygen enrichment. Hardening directly induced by hydrogen was much less significant. - Highlights: •More than 50% of the gaseous hydrogen produced by the inner clad oxidation absorbed and trapped into prior-β layer. •High hydrogen and oxygen local concentrations, up to 3000–4000 wt. ppm and 1.0–1.2 wt.% respectively, within the β phase. •Enhanced oxygen diffusion into hydrogen enriched prior-β layer, with locally thinner α(O) and thicker prior-β layers. •Post-quenching hardening of the prior-β structure mainly related to the (local) oxygen concentration.

  8. High resolution radio observations of nuclear and circumnuclear regions of luminous infrared galaxies (LIRGs)

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, A; Perez-Torres, M A [Instituto de Astrofisica de Andalucia (IAA, CSIC), PO Box 3004, 18080-Granada (Spain); Colina, L [Instituto de Estructura de la Materia - IEM, CSIC, C, Serrano 115, 28005 Madrid (Spain); Torrelles, J M [Instituto de Ciencias del Espacio (ICE, CSIC) and IEEC, Gran Capita 2-4, 08034 Barcelona (Spain)], E-mail: antxon@iaa.es, E-mail: torres@iaa.es, E-mail: colina@damir.iem.csic.es, E-mail: torrelle@ieec.fcr.es

    2008-10-15

    High-resolution radio observations of the nuclear region of Luminous and Ultraluminous Infrared Galaxies (ULIRGs) have shown that its radio structure consists of a compact high surface-brightness central radio source immersed in a diffuse low brightness circumnuclear halo. While the central component could be associated with an AGN or compact star-forming regions where radio supernovae are exploding, it is well known that the circumnuclear regions host bursts of star-formation. The studies of radio supernovae can provide essential information about stellar evolution and CSM/ISM properties in regions hidden by dust at optical and IR wavelengths. In this contribution, we show results from radio interferometric observations from NGC 7469, IRAS 18293-3413 and IRAS 17138-1017 where three extremely bright radio supernovae have been found. High-resolution radio observations of these and other LIRGs would allow us to determine the core-collapse supernova rate in them as well as their star-formation rate.

  9. Synchrotron radiation XRF microprobe study of human bone tumor slice

    International Nuclear Information System (INIS)

    Huang Yuying; Zhao Limin; Wang Zhouguang; Shao Hanru; Li Guangcheng; Wu Yingrong; He Wei; Lu Jianxin; He Rongguo

    1999-01-01

    The experimental apparatus of X-ray fluorescence (XRF) microprobe analysis at Beijing Synchrotron Radiation Facility (BSRF) is described. Using the bovine liver as the standard reference, the minimum detection limit (MDL) of trace element was measured to determine the capability of biological sample analysis by synchrotron radiation XRF microprobe. The relative change of the content of the major or trace element in the normal and tumor part of human bone tissue slice was investigated. The experimental result relation to the clinical medicine was also discussed. (author)

  10. Super-resolution mapping of scaffold nucleoporins in the nuclear pore complex.

    Science.gov (United States)

    Ma, Jiong; Kelich, Joseph M; Junod, Samuel L; Yang, Weidong

    2017-04-01

    The nuclear pore complex (NPC), composed of ∼30 different nucleoporins (Nups), is one of the largest supramolecular structures in eukaryotic cells. Its octagonal ring scaffold perforates the nuclear envelope and features a unique molecular machinery that regulates nucleocytoplasmic transport. However, the precise copy number and the spatial location of each Nup in the native NPC remain obscure due to the inherent difficulty of counting and localizing proteins inside of the sub-micrometer supramolecular complex. Here, we combined super-resolution single-point edge-excitation subdiffraction (SPEED) microscopy and nanobody-specific labeling to reveal the spatial distribution of scaffold Nups within three separate layers in the native NPC with a precision of ∼3 nm. Our data reveal both the radial and axial spatial distributions for Pom121, Nup37 and Nup35 and provide evidence for their copy numbers of 8, 32 and 16, respectively, per NPC. This approach can help pave the path for mapping the entirety of Nups in native NPCs and also other structural components of macromolecular complexes. © 2017. Published by The Company of Biologists Ltd.

  11. Resolution proposition aiming at the creation of an inquiry commission related to dysfunctions in the nuclear sector in France

    International Nuclear Information System (INIS)

    2011-06-01

    After a reference to the Fukushima accident, the authors comment several issues concerning the nuclear industry in France: safety of nuclear power plants, right to information, financial difficulties of the sector, uncertainties regarding the EPR, storages discovered on the Cadarache site, wastes which have been exported to Siberia, respect of human rights in Africa (notably in Niger and Congo where AREVA operates), espionage activities. These issues are supposed to inspire a parliamentary resolution

  12. Nuclear microprobe local characterization of YBaCuO superconductors

    Science.gov (United States)

    Berger, P.; Berthier, B.; Revel, G.; Trocellier, P.

    1995-09-01

    Stoichiometric local characterizations of YBaCuO oxides have been performed using a 1.4 MeV deuteron microbeam. A beam with a size of 10 × 15 μm 2 allows the observation of variations of x = 0.2 in sintered YBa 2Cu 3O 7-x. Local variations of oxygen stoichiometry in a melt-textured sample, correlated with the microstructure, have been observed. In spite of the degradation of the sample under the beam, oxygen measurements seem to remain significant for doses above 10 18 ions/cm 2.

  13. Laser microprobe mass spectrometry: Potential and limitations for inorganic and organic micro-analysis. Pt. 2

    International Nuclear Information System (INIS)

    Vaeck, I. van; Gijbels, R.

    1990-01-01

    Laser microprobe mass spectrometry (LMMS) employs a highly focused UV laser beam to ionise a microvolume in the order of 1 μm 3 . The produced ions are then mass-separated in a time-of-flight (TOF) or a Fourier Transform (FT) mass spectrometer. The technique allows element localisation, detailed speciation of inorganic substances and structural information of organic molecules. Inorganic applications are treated in the preceding part. This paper will focus on the organic aspects. Selected examples illustrate that TOF LMMS can achieve structural characterisation of molecules, untractable by conventional mass spectrometric techniques. Applicability to the analysis with high spatial resolution is shown and the need for surface availability of organic target molecules is discussed. The recently developed FT LMMS may fulfil the need for better mass resolution. However, the comparability of FT LMMS results with TOF LMMS data is not yet obvious. (orig.)

  14. An SU-8-based microprobe with a nanostructured surface enhances neuronal cell attachment and growth

    Science.gov (United States)

    Kim, Eunhee; Kim, Jin-Young; Choi, Hongsoo

    2017-12-01

    Microprobes are used to repair neuronal injury by recording electrical signals from neuronal cells around the surface of the device. Following implantation into the brain, the immune response results in formation of scar tissue around the microprobe. However, neurons must be in close proximity to the microprobe to enable signal recording. A common reason for failure of microprobes is impaired signal recording due to scar tissue, which is not related to the microprobe itself. Therefore, the device-cell interface must be improved to increase the number of neurons in contact with the surface. In this study, we developed nanostructured SU-8 microprobes to support neuronal growth. Nanostructures of 200 nm diameter and depth were applied to the surface of microprobes, and the attachment and neurite outgrowth of PC12 cells on the microprobes were evaluated. Neuronal attachment and neurite outgrowth on the nanostructured microprobes were significantly greater than those on non-nanostructured microprobes. The enhanced neuronal attachment and neurite outgrowth on the nanostructured microprobes occurred in the absence of an adhesive coating, such as poly- l-lysine, and so may be useful for implantable devices for long-term use. Therefore, nanostructured microprobes can be implanted without adhesive coating, which can cause problems in vivo over the long term.

  15. Single ion hit detection set-up for the Zagreb ion microprobe

    Science.gov (United States)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  16. Ion microprobe imaging of 44Ca-labeled mammalian chromosomes

    International Nuclear Information System (INIS)

    Levi-Setti, R.; Gavrilov, K.L.; Strissel, P.L.; Strick, R.

    2004-01-01

    In our previous investigation, we showed for the first time high-resolution analytical images of the cation composition of mammalian interphase and mitotic cells as well as of isolated metaphase chromosomes using the University of Chicago scanning ion microprobe (UC-SIM). In order to preserve the ionic integrity of the analyzed cells and prevent the well known occurrence of analytical artifacts due to the high diffusivity of cations in biological samples we used fast cryo-preservation methods (freeze-drying and freeze fracture), without any pre-fixations or washes. We identified the role of the cations in chromosome structure and maintenance using SIMS imaging and immunfluorescence methodologies. Importantly, we determined that the above cations are essential participants in chromosome condensation and maintenance of chromatin higher order structure, through their presumed function in DNA electrostatic neutralization and the direct interaction of Ca 2+ , in particular, with structural proteins. In addition, both Ca 2+ and Mg 2+ showed the same cell cycle regulation where during interphase both cations were enriched in the cytosol, particularly in organelles then at mitosis became specifically bound to chromatin. Our present research interest focuses on a more detailed analysis of the distribution of Ca 2+ throughout the different cell cycle stages, e.g. G1, G2 and mitosis. We have chosen the stable isotope 44 Ca as a tracer to follow Ca 2+ throughout the cell cycle. This nuclide occurs naturally in the ratio 44 Ca/ 40 Ca+ 44 Ca of 2.06%, so that incorporation at higher concentrations into chromatin or other cellular components should be easily detected by SIMS. Such incorporation can be obtained either by growing cells in a medium where ordinary Ca is replaced entirely by 44 Ca, or by replacing the cell culture medium with the 44 Ca medium for a gated time span (pulsing), after appropriate cell cycle stage synchronization. In this paper, we describe our

  17. Nuclear labelling after prolonged 3H-uridine incorporation as visualized by high resolution autoradiography

    International Nuclear Information System (INIS)

    Fakan, S.; Bernhard, W.

    1973-01-01

    Localization of radioactive labeling over the nuclei of BSC 1 cells is visualized after long periods of 3 H-5-uridine incubation followed or not followed by periods of postincubation in nonradioactive medium for up to several days, using high resolution autoradiography combined with a preferential staining method for ribonucleoproteins. It is shown that when cells are labeled for 1 or 6 h with 3 H-uridine and postincubated with a nonradioactive medium up to several days, there is always some radioactivity present in the nucleolus and nucleoplasm. When sections of cells fixed after 1 h of labeling followed by 24 h of postincubation are treated with RNase, part of the radioactivity found in the nucleus disappears almost completely only after a succeeding DNase digestion. The majority of interchromatin granules are weakly labeled after most incubation times, with the label localized rather at the periphery of clusters of granules, or are unlabeled. The results are discussed in the context of recent biochemical findings. It is proposed that interchromatin granules might represent a structure containing a limited quantity of slowly labeled nuclear RNA

  18. The Highest Resolution X-ray View of the Nuclear Region of NGC 4151

    Science.gov (United States)

    Wang, Junfeng; Fabbiano, G.; Karovska, M.; Elvis, M.; Risaliti, G.; Zezas, A.; Mundell, C. G.

    2009-09-01

    We report high resolution imaging of the nucleus of the Seyfert 1 galaxy NGC 4151 obtained with a 50 ks Chandra HRC observation. The HRC image resolves the emission on spatial scales of 0.5 arcsec (30 pc), showing an extended X-ray morphology overall consistent with the narrow line region seen in optical line emission. Removal of the bright point-like nuclear source and image deconvolution technique both reveal X-ray enhancements that closely match the substructures seen in the HST [OIII] image and prominent knots in the radio jet. We find that most of the NLR clouds in NGC 4151 have [OIII] to soft X-ray ratio consistent with the values observed in NLRs of some Seyfert 2 galaxies, which indicates a uniform ionization parameter even at large radii and a density dependence ∝ r^{-2} as expected in the disk wind scenario. We examine various X-ray emission mechanisms of the radio jet and consider thermal emission from interaction between radio outflow and the NLR clouds the most probable origin for the X-ray emission associated with the jet.

  19. Resolution of the neutron diffractometer of the Mexican Nuclear Center; Resolucion del difractometro de neutrones del Centro Nuclear de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Garcia C, R.M. [Administracion Central de Laboratorio y Servicios Cientificos, Legaria 608, Col. Irrigacion, 11500 Mexico D.F. (Mexico); Ita T, A. De [UAM-A, San Pablo 180, Col. Reynosa Tamaulipas, 02200 Mexico D.F. (Mexico)

    2003-07-01

    The neutron diffractometer has three collimators and a monochromator of which it depends the resolution of the same one and exists a commitment between the resolution of the diffractometer and its intensity; if it is sought to work with more resolution, the intensity will diminish, and also, if one has little volume of the material, the diffracted light it is diminished, so the selection of the values of the collimators is this way important to have an unique value of the resolution of the diffractometer. (Author)

  20. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Surendra P., E-mail: spv@cie.unam.mx [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Pandarinath, Kailasa [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Velasco-Tapia, Fernando [Facultad de Ciencias de la Tierra, Universidad Autonoma de Nuevo Leon, Carretera Linares-Cerro Prieto km. 8, Linares, N.L. 67700 (Mexico); Rodriguez-Rios, Rodolfo [Facultad de Ingenieria e Instituto de Geologia, Universidad Autonoma de San Luis Potosi, Av. Dr. Manuel Nava No. 8, Zona Universitaria, San Luis Potosi, S.L.P. 78240 (Mexico)

    2009-04-13

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  1. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    International Nuclear Information System (INIS)

    Verma, Surendra P.; Pandarinath, Kailasa; Velasco-Tapia, Fernando; Rodriguez-Rios, Rodolfo

    2009-01-01

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  2. Applications of the ion microprobe to geochemistry and cosmochemistry

    International Nuclear Information System (INIS)

    Shimizu, N.; Hart, S.R.

    1982-01-01

    When a solid surface is subjected to a bombardment of energetic ions, material is ejected from the surface in a process known as sputtering. A part of the sputtered material is ionized and these secondary ions can be analyzed with a mass spectrometer according to a technique known as secondary ion mass spectrometry (SIMS). A description is presented of the present status of geochemical and cosmochemical applications of the ion microprobe. Attention is given to the sputtering event, molecular ion interferences, aspects of isotopic fractionation, secondary ion intensities in polycomponent materials, and questions of trace element analysis. Geochemical applications of the ion microprobe are based on certain advantages over other analytical techniques. These advantages are related to high sensitivity, low background, and the capability of in situ analysis of isotopic composition. The distribution of trace elements in minerals is considered, along with isotope anomalies, isotope zoning, diffusion studies, and depth profiling

  3. Laser microprobe mass spectrometry: Potential and limitations for inorganic and organic micro-analysis. Pt. 1

    International Nuclear Information System (INIS)

    Vaeck, I. van; Gijbels, R.

    1990-01-01

    Laser microprobe mass spectrometry (LMMS) employs a highly focused UV laser beam to ionise a microvolume in the order of 1 μm 3 . The ions produced are then mass-separated in a time-of-flight (TOF) or a Fourier Transform (FT) mass spectrometer. TOF LMMS allows element localisation, detailed speciation of inorganic substances and structural information of organic molecules. Quantitation is difficult. This paper focuses on instrumental aspects and inorganic analysis. Organic applications are treated in part II of this series. Selected examples illustrate that TOF LMMS is a valuable tool for the qualitative characterisation of micro-samples. Also, the applicability to the analysis with high spatial resolution is shown. The current technology and the prospects from the recent FTMS development are discussed. (orig.)

  4. High-resolution characterization of oxidation mechanism of zirconium nuclear fuel cladding alloys

    International Nuclear Information System (INIS)

    Hu, J.; Lozano-Perez, S.; Grovenor, C.

    2015-01-01

    Full text of publication follows. Zirconium alloys are used extensively as cladding materials in modern light water reactors to separate the uranium dioxide (UO 2 ) fuel rods and the coolant water in order to prevent the escape of radioactive fission products whilst maintaining heat transfer to the coolant. With increasing demand for high burn-up in modern nuclear reactors, environmental degradation of these alloys is now the life limiting factor for fuel assemblies. As part of the MUZIC-2 collaboration studying oxidation and hydrogen pickup in Zr alloys, several high resolution analysis techniques have been used to study the microstructure of a range of commercial and developmental Zr alloys. The sample used for this investigation was prepared from a Westinghouse TM developmental alloy with composition of Zr-0.9Nb-0.01Sn-0.08Fe (wt %) in the recrystallized condition. The sample was oxidised in an autoclave at EDF Energy under simulated PWR water conditions at 360 C. degrees for 360 days. Using Transmission Electron Microscope (TEM), we have studied the development of the equiaxed-columnar-equiaxed grain structure, and observe that the columnar grains are both longer and show a stronger preferred texture in more corrosion-resistant alloys. Fresnel imaging revealed the existence of both parallel interconnected pores and some vertically interconnected pores along the columnar oxide grain boundaries, which become more disconnected near the metal-oxide interface. Electron Energy Loss Spectroscopy (EELS) provided accurate quantitative analysis of the oxygen concentration across the interface, identifying the existence of local regions of stoichiometric ZrO and Zr 3 O 2 with varying thickness. These observations will be discussed in the context of current models for oxidation in zirconium alloys. (authors)

  5. Raman microprobe study of heat-treated pitches

    Energy Technology Data Exchange (ETDEWEB)

    Cottinet, D.; Couderc, P.; Saint Romain, J.L.; Dhamelincourt, P.

    1988-01-01

    A series of heat-treated pitches from the same coal-tar precursor is investigated by means of a Raman microprobe. Separated Raman spectra are obtained for the isotropic phase and the mesophase. The evolutions observed are characteristic of the structural rearrangement change in the two phases. They correlate well with the observations reported in literature and obtained by using different methods of structural investigations.

  6. Applications of heavy ion microprobe for single event effects analysis

    International Nuclear Information System (INIS)

    Reed, Robert A.; Vizkelethy, Gyorgy; Pellish, Jonathan A.; Sierawski, Brian; Warren, Kevin M.; Porter, Mark; Wilkinson, Jeff; Marshall, Paul W.; Niu, Guofu; Cressler, John D.; Schrimpf, Ronald D.; Tipton, Alan; Weller, Robert A.

    2007-01-01

    The motion of ionizing-radiation-induced rogue charge carriers in a semiconductor can create unwanted voltage and current conditions within a microelectronic circuit. If sufficient unwanted charge or current occurs on a sensitive node, a variety of single event effects (SEEs) can occur with consequences ranging from trivial to catastrophic. This paper describes the application of heavy ion microprobes to assist with calibration and validation of SEE modeling approaches

  7. A study of VMS ore deposits by the proton microprobe

    International Nuclear Information System (INIS)

    Huston, D.L.; Large, R.R.; Bottril, R.S.; Sie, S.H.; Ryan, C.G.

    1991-01-01

    As part of studies into the mineralogical distribution of gold in volcanogenic massive sulfide (VMS) ore deposits PIXE analysis by the proton microprobe has been used to determine the gold content of pyrite and arsenopyrite from the Rosebery, Mt. Chalmers and Mt. Lyell deposits. In addition, the concentrations of Co, Ni, Cu, Zn, As, Sr, Y, Zr, Mo, Ag, Sb, Te, Au, Tl, Pb and Bi were also determined. 4 refs., 1 tab

  8. Digital pulse processor for ion beam microprobe imaging

    International Nuclear Information System (INIS)

    Bogovac, M.; Jaksic, M.; Wegrzynek, D.; Markowicz, A.

    2009-01-01

    Capabilities of spectroscopic ion beam analysis (IBA) techniques that are available in ion microprobe facilities can be greatly improved by the use of digital pulse processing. We report here development of a digital multi parameter data acquisition system suitable for IBA imaging applications. Input signals from charge sensitive preamplifier are conditioned by using a simple circuit and digitized with fast ADCs. The digitally converted signals are processed in real time using FPGA. Implementation of several components of the system is presented.

  9. Hydrogen depth resolution in multilayer metal structures, comparison of elastic recoil detection and resonant nuclear reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Wielunski, L.S. E-mail: leszekw@optushome.com.au; Grambole, D.; Kreissig, U.; Groetzschel, R.; Harding, G.; Szilagyi, E

    2002-05-01

    Four different metals: Al, Cu, Ag and Au have been used to produce four special multilayer samples to study the depth resolution of hydrogen. The layer structure of each sample was analysed using 2 MeV He Rutherford backscattering spectrometry, 4.5 MeV He elastic recoil detection (ERD) and 30 MeV F{sup 6+} HIERD. Moreover the hydrogen distribution was analysed in all samples using H({sup 15}N, {alpha}{gamma}){sup 12}C nuclear reaction analysis (NRA) with resonance at 6.385 MeV. The results show that the best depth resolution and sensitivity for hydrogen detection are offered by resonance NRA. The He ERD shows good depth resolution only for the near surface hydrogen. In this technique the depth resolution is rapidly reduced with depth due to multiple scattering effects. The 30 MeV F{sup 6+} HIERD demonstrated similar hydrogen depth resolution to He ERD for low mass metals and HIERD resolution is substantially better for heavy metals and deep layers.

  10. Crocus sativus Petals: Waste or Valuable Resource? The Answer of High-Resolution and High-Resolution Magic Angle Spinning Nuclear Magnetic Resonance.

    Science.gov (United States)

    Righi, Valeria; Parenti, Francesca; Tugnoli, Vitaliano; Schenetti, Luisa; Mucci, Adele

    2015-09-30

    Intact Crocus sativus petals were studied for the first time by high-resolution magic angle spinning nuclear magnetic resonance (HR-MAS NMR) spectroscopy, revealing the presence of kinsenoside (2) and goodyeroside A (3), together with 3-hydroxy-γ-butyrolactone (4). These findings were confirmed by HR-NMR analysis of the ethanol extract of fresh petals and showed that, even though carried out rapidly, partial hydrolysis of glucopyranosyloxybutanolides occurs during extraction. On the other hand, kaempferol 3-O-sophoroside (1), which is "NMR-silent" in intact petals, is present in extracts. These results suggest to evaluate the utilization of saffron petals for phytopharmaceutical and nutraceutical purposes to exploit a waste product of massive production of commercial saffron and point to the application of HR-MAS NMR for monitoring bioactive compounds directly on intact petals, avoiding the extraction procedure and the consequent hydrolysis reaction.

  11. NRC program for the resolution of generic issues related to nuclear power plants. (Includes plans for the resolution of ''unresolved safety issues'' pursuant to Section 210 of the Energy Reorganization Act of 1974, as amended)

    International Nuclear Information System (INIS)

    1977-12-01

    This report provides a description of the Nuclear Regulatory Commission's Program for the Resolution of Generic Issues Related to Nuclear Power Plants. The NRC program is of considerably broader scope than the ''Unresolved Safety Issues Plan'' required by Section 210. The NRC program does include plans for the resolution of ''Unresolved Safety Issues''; however, in addition, it includes generic tasks for the resolution of environmental issues, for the development of improvements in the reactor licensing process and for consideration of less conservative design criteria or operating limitations in areas where over conservatisms may be unnecessarily restrictive or costly

  12. Generic safety issues for nuclear power plants with pressurized heavy water reactors and measures for their resolution

    International Nuclear Information System (INIS)

    2007-06-01

    be used in reassessing the safety of individual operating plants. In 1998, the IAEA completed IAEA-TECDOC-1044 entitled Generic Safety Issues for Nuclear Power Plants with Light Water Reactors and Measures Taken for their Resolution and established the associated LWRGSIDB database (Computer Manual Series No. 13). The present compilation, which is based on broad international experience, is an extension of this work to cover pressurized heavy water reactors (PHWRs). As in the case of LWRs, it is one element in the framework of IAEA activities to assist Member States in reassessing the safety of operating nuclear power plants. It addresses generic safety issues identified in nuclear power plants using PHWRs. In most cases, the measures taken or planned to resolve these issues are also identified. The work on this report was initiated by the Senior Regulators of Countries Operating CANDU-Type Nuclear Power Plants at one of their annual meetings. It was carried out within the framework of the IAEA's programme on National Regulatory Infrastructure for Nuclear Installation Safety and serves to enhance regulatory effectiveness through the exchange of safety related information

  13. Generic safety issues for nuclear power plants with light water reactors and measures taken for their resolution

    International Nuclear Information System (INIS)

    1998-09-01

    The IAEA Conference on 'The Safety of Nuclear Power: Strategy for the Future' in 1991 was a milestone in nuclear safety. Two of the important items addressed by this conference were ensuring and enhancing safety of operating plants and treatment of nuclear power plants built to earlier safety standards. A number of publications related to these two items issued subsequent to this conference were: A Common Basis for Judging the Safety of Nuclear Power Plants Built to Earlier Standards, INSAG-9 (1995), the IAEA Safety Guide 50-SG-O12, periodic Safety Review of Operational Nuclear Power Plants (1994) and an IAEA publication on the Safety Evaluation of Operating Nuclear Power Plants Built to Earlier Standards - A Common Basis for Judgement (1997). Some of the findings of the 1991 Conference have not yet been fully addressed. An IAEA Symposium on reviewing the Safety of Existing Nuclear Power Plants in 1996 showed that there is an urgent need for operating organizations and national authorities to review operating nuclear power plants which do not meet the high safety levels of the vast majority of plants and to undertake improvements with assistance from the international community if required. Safety reviews of operating nuclear power plants take on added importance in the context of the Convention on Nuclear safety and its implementation. The purpose of this TECDOC compilation based on broad international experience, is to assist the Member States in the reassessment of operating plants by providing a list of generic safety issues identified in nuclear power plants together with measures taken to resolve these issues. These safety issues are generic in nature with regard to light water reactors and the measures for their resolution are for use as a reference for the safety reassessment of operating plants. The TECDOC covers issues thought to be significant to Member States based on consensus process. It provides an introduction to the use of generic safety issues for

  14. A resolution adaptive deep hierarchical (RADHicaL) learning scheme applied to nuclear segmentation of digital pathology images.

    Science.gov (United States)

    Janowczyk, Andrew; Doyle, Scott; Gilmore, Hannah; Madabhushi, Anant

    2018-01-01

    Deep learning (DL) has recently been successfully applied to a number of image analysis problems. However, DL approaches tend to be inefficient for segmentation on large image data, such as high-resolution digital pathology slide images. For example, typical breast biopsy images scanned at 40× magnification contain billions of pixels, of which usually only a small percentage belong to the class of interest. For a typical naïve deep learning scheme, parsing through and interrogating all the image pixels would represent hundreds if not thousands of hours of compute time using high performance computing environments. In this paper, we present a resolution adaptive deep hierarchical (RADHicaL) learning scheme wherein DL networks at lower resolutions are leveraged to determine if higher levels of magnification, and thus computation, are necessary to provide precise results. We evaluate our approach on a nuclear segmentation task with a cohort of 141 ER+ breast cancer images and show we can reduce computation time on average by about 85%. Expert annotations of 12,000 nuclei across these 141 images were employed for quantitative evaluation of RADHicaL. A head-to-head comparison with a naïve DL approach, operating solely at the highest magnification, yielded the following performance metrics: .9407 vs .9854 Detection Rate, .8218 vs .8489 F -score, .8061 vs .8364 true positive rate and .8822 vs 0.8932 positive predictive value. Our performance indices compare favourably with state of the art nuclear segmentation approaches for digital pathology images.

  15. Resolution 62/96 Regulation for the accounting and control of the nuclear materials

    International Nuclear Information System (INIS)

    1996-01-01

    The present Regulation is a complementary disposition of the ordinance number 208 of May 24 National System of Accounting and Control of Nuclear Materials and it has as objective to establish the relative norms to this System. As for the responsibilities it establish that the National Center of Nuclear Security (CNSN) it is the responsible for the execution from the relative tasks to the National System of Accounting and Control of Nuclear Materials. It establishes the regulations for the following aspects: licenses and authorizations for the transportation of the nuclear material and important components, Of the ceasing of the Accounting and Control, Of the Accounting and Control of the Nuclear Materials, Control of the Important Components, The Inspections, International Organism of the Atomic Energy Safeguards

  16. A tunable x-ray microprobe using synchrotron radiation

    International Nuclear Information System (INIS)

    Wu, Y.; Thompson, A.C.; Underwood, J.H.; Giauque, R.D.; Chapman, K.; Rivers, M.L.; Jones, K.W.

    1989-08-01

    We describe an x-ray microprobe using multilayer mirrors. Previously, we had demonstrated a Kirkpatrick-Baez type focusing system working at both 8 and 10 keV and successfully applied it to a variety of applications, including the determination of elemental contents in fluid inclusions. In this paper, we show that the usable excitation energy for this microprobe is not restricted to between 8 and 10 keV, and furthermore, it can be simply tuned in operation. A 10-keV x-ray fluorescence microprobe can be used to measure the concentration of the elements form potassium (Z = 19) to zinc (Z = 30) using K x-ray lines, and from cadmium (Z = 48) to erbium (Z = 68) using L x-ray lines. There are a number of geologically important elements in the gap between gallium (Z = 31) and silver(Z = 47) and also with Z > 68. In order to cover this range, a higher excitation energy is required. On the other hand, for samples that contain major elements with absorption edges lower than the excitation energy, it would be hard to detect other mirror elements because of the strong signal from the major elements and the background they produce. In this case, a tunable x-ray source can be used to avoid the excitation of the major elements. We demonstrate that, with the existing setup, it is possible to tune the excitation energy from 6 keV to 14 keV, in this range, the intensity does not decrease by more than one order of magnitude. As an illustration, a geological sample was examined by using two different excitation energy range as well as the possibility of improving the intensity. 11 refs., 5 figs

  17. X-ray microprobe for the microcharacterization of materials

    International Nuclear Information System (INIS)

    Sparks, C.J.; Ice, G.E.

    1988-01-01

    The unique properties of x rays offer many advantages over those of electrons and other charged particles for the microcharacterization of materials. X rays are more efficient in exciting characteristic x-ray fluorescence and produce higher fluorescent signal-to-background ratios than obtained with electrons. Such x-ray microprobes will also produce unprecedentedly low levels of detection in diffraction, EXAFS, Auger, and photoelectron spectroscopies for structural and chemical characterization and elemental identification. These major improvements in microcharacterization capabilities will have wide-ranging ramifications not only in materials science but also in physics, chemistry, geochemistry, biology, and medicine. 24 refs., 6 figs., 2 tabs

  18. X-ray Microprobe for Fluorescence and Diffraction Analysis

    International Nuclear Information System (INIS)

    Ice, G.E.

    2005-01-01

    X-ray diffraction (see unit 1.1) and x-ray excited fluorescence analysis are powerful techniques for the nondestructive measurement of crystal structure and chemical composition. X-ray fluorescence analysis is inherently nondestructive with orders of magnitude lower power deposited for the same detectable limit as with fluorescence excited by charged particle probes (Sparks, 1980). X-ray diffraction analysis is sensitive to crystal structure with orders-of-magnitude greater sensitivity to crystallographic strain than electron probes (Rebonato, et al. 1989). When a small-area x-ray microbeam is used as the probe, chemical composition (Z>14), crystal structure, crystalline texture, and crystalline strain distributions can be determined. These distributions can be studied both at the surface of the sample and deep within the sample (Fig. 1). Current state-of-the-art can achieve an ∼1 mm-D x-ray microprobe and an ∼0.1 mm-D x-ray microprobe has been demonstrated (Bilderback, et al., 1994). Despite their great chemical and crystallographic sensitivities, x-ray microprobe techniques have until recently been restricted by inefficient x-ray focusing optics and weak x-ray sources; x-ray microbeam analysis was largely superseded by electron techniques in the 50's. However, interest in x-ray microprobe techniques has now been revived (Howells, et al., 1983; Ice and Sparks, 1984; Chevallier, et al., 1997; Riekel 1992; Thompson, el al., 1992; and Making and Using... 1997) by the development of efficient x-ray focusing optics and ultra-high intensity synchrotron x-ray sources (Buras and Tazzari, 1984; Shenoy, et al., 1988). These advances have increased the achievable microbeam flux by more than 11 orders of magnitude (Fig. 2) (Ice, 1997); the flux in a tunable 1 mm-D beam on a 'so called' 3rd-generation synchrotron source such as the APS can exceed the flux in a fixed-energy mm2 beam on a conventional source. These advances make x-ray microfluorescence and x

  19. Cryosystem for cathodoluminescence investigations by means of electron microprobe analysis

    International Nuclear Information System (INIS)

    Schreiber, J.

    1982-01-01

    A cryosystem is presented which has been designed as auxiliary equipment for electron beam microprobes used in cathodoluminescence studies. The sample holder temperature is adjustable down to 66 K with an accuracy of 0.5 K. Finally, experimental results (transmission spectra and cathodoluminescence spectra of N-doped GaP epitaxial layers at 80 K; changes in microscopic cathodoluminescence distribution at small angle grain boundaries at the (0001) plane of CdS during temperature decrease from 300 to 80 K) obtained by means of the described measuring equipment are given for illustration

  20. Using targeted enrichment of nuclear genes to increase phylogenetic resolution in the neotropical rain forest genus Inga (Leguminosae: Mimosoideae

    Directory of Open Access Journals (Sweden)

    James A Nicholls

    2015-09-01

    Full Text Available Evolutionary radiations are prominent and pervasive across many plant lineages in diverse geographical and ecological settings; in neotropical rainforests there is growing evidence suggesting that a significant fraction of species richness is the result of recent radiations. Understanding the evolutionary trajectories and mechanisms underlying these radiations demands much greater phylogenetic resolution than is currently available for these groups. The neotropical tree genus Inga (Leguminosae is a good example, with ~300 extant species and a crown age of 2-10 MY, yet over 6kb of plastid and nuclear DNA sequence data gives only poor phylogenetic resolution among species. Here we explore the use of larger-scale nuclear gene data obtained though targeted enrichment to increase phylogenetic resolution within Inga. Transcriptome data from three Inga species were used to select 264 nuclear loci for targeted enrichment and sequencing. Following quality control to remove probable paralogs from these sequence data, the final dataset comprised 259,313 bases from 194 loci for 24 accessions representing 22 Inga species and an outgroup (Zygia. Bayesian phylogenies reconstructed using either all loci concatenated or a subset of 60 loci in a gene-tree/species-tree approach yielded highly resolved phylogenies. We used coalescent approaches to show that the same targeted enrichment data also have significant power to discriminate among alternative within-species population histories in the widespread species I. umbellifera. In either application, targeted enrichment simplifies the informatics challenge of identifying orthologous loci associated with de novo genome sequencing. We conclude that targeted enrichment provides the large volumes of phylogenetically-informative sequence data required to resolve relationships within recent plant species radiations, both at the species level and for within-species phylogeographic studies.

  1. High-resolution γ-ray spectroscopy: a versatile tool for nuclear β-decay studies at TRIUMF-ISAC

    Science.gov (United States)

    Ball, G. C.; Achtzehn, T.; Albers, D.; Khalili, J. S. Al; Andreoiu, C.; Andreyev, A.; Ashley, S. F.; Austin, R. A. E.; Becker, J. A.; Bricault, P.; Chan, S.; Chakrawarthy, R. S.; Churchman, R.; Coombes, H.; Cunningham, E. S.; Daoud, J.; Dombsky, M.; Drake, T. E.; Eshpeter, B.; Finlay, P.; Garrett, P. E.; Geppert, C.; Grinyer, G. F.; Hackman, G.; Hanemaayer, V.; Hyland, B.; Jones, G. A.; Koopmans, K. A.; Kulp, W. D.; Lassen, J.; Lavoie, J. P.; Leslie, J. R.; Litvinov, Y.; Macdonald, J. A.; Mattoon, C.; Melconian, D.; Morton, A. C.; Osborne, C. J.; Pearson, C. J.; Pearson, M.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Schumaker, M. A.; Schwarzenberg, J.; Scraggs, H. C.; Smith, M. B.; Svensson, C. E.; Valiente-Dobon, J. J.; Waddington, J. C.; Walker, P. M.; Wendt, K.; Williams, S. J.; Wood, J. L.; Zganjar, E. F.

    2005-10-01

    High-resolution γ-ray spectroscopy is essential to fully exploit the unique, high-quality beams available at the next generation of radioactive ion beam facilities such as the TRIUMF isotope separator and accelerator (ISAC). The 8π spectrometer, which consists of 20 Compton-suppressed HPGe detectors, has recently been reconfigured for a vigorous research programme in weak interaction and nuclear structure physics. With the addition of a variety of ancillary detectors it has become the world's most powerful device dedicated to β-decay studies. This paper provides a brief overview of the apparatus and highlights from recent experiments.

  2. Realtime control system for microprobe beamline at PLS

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, J.C.; Lee, J.W.; Kim, K.H.; Ko, I.S. [Pohang Accelerator Laboratory, POSTECH, Pohang (Korea)

    1998-11-01

    The microprobe beamline of the Pohang Light Source (PLS) consists of main and second slits, a microprobe system, two ion chambers, a video-microscope, and a Si(Li) detector. These machine components must be controlled remodely through the computer system to make user's experiments precise and speedy. A real-time computer control system was developed to control and monitor these components. A VMEbus computer with an OS-9 real-time operating system was used for the low-level data acquisition and control. VME I/O modules were used for the step motor control and the scalar control. The software has a modular structure for the maximum performance and the easy maintenance. We developed the database, the I/O driver, and the control software. We used PC/Windows 95 for the data logging and the operator interface. Visual C{sup ++} was used for the graphical user interface programming. RS232C was used for the communication between the VME and the PC. (author)

  3. General theory of three-dimensional radiance measurements with optical microprobes RID A-1977-2009

    DEFF Research Database (Denmark)

    FukshanskyKazarinova, N.; Fukshansky, L.; Kuhl, M.

    1997-01-01

    Measurements of the radiance distribution and fluence rate within turbid samples with fiber-optic radiance microprobes contain a large variable instrumental error caused by the nonuniform directional sensitivity of the microprobes. A general theory of three-dimensional radiance measurements...

  4. Optimization of the working distance of an ion microprobe-forming system

    International Nuclear Information System (INIS)

    Melnik, K.I.; Magilin, D.V.; Ponomarev, A.G.

    2009-01-01

    A high-resolution ion microprobe necessitates the use of a small working distance (the distance from the final quadrupole lens of a probe-forming system to the specimen) in order to produce a large demagnification. But at the same time a small working distance is a source of a number of practical difficulties. We have presented an approach for determining a working distance that provides the best spatial resolution with the main practical limitations taken into account. We used a probe-forming system acceptance as a criterion of optimality. The calculations have revealed the existence of an optimal working distance in a set of common probe-forming systems, but it can be achieved only after changing of a design of a final quadrupole lens. We proposed a possible design of conic lens that allows solving the problem of detectors location and creating a short focus system. Three-dimensional calculations of magnetic field within this lens predicted a good quality of field structure.

  5. Solid-State NMR on bacterial cells: selective cell wall signal enhancement and resolution improvement using dynamic nuclear polarization

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Bardet, Michel; De Paepe, Gael; Hediger, Sabine; Ayala, Isabel; Simorre, Jean-Pierre

    2013-01-01

    Dynamic nuclear polarization (DNP) enhanced solid-state nuclear magnetic resonance (NMR) has recently emerged as a powerful technique for the study of material surfaces. In this study, we demonstrate its potential to investigate cell surface in intact cells. Using Bacillus subtilis bacterial cells as an example, it is shown that the polarizing agent 1-(TEMPO-4-oxy)-3-(TEMPO-4-amino)propan-2-ol (TOTAPOL) has a strong binding affinity to cell wall polymers (peptidoglycan). This particular interaction is thoroughly investigated with a systematic study on extracted cell wall materials, disrupted cells, and entire cells, which proved that TOTAPOL is mainly accumulating in the cell wall. This property is used on one hand to selectively enhance or suppress cell wall signals by controlling radical concentrations and on the other hand to improve spectral resolution by means of a difference spectrum. Comparing DNP-enhanced and conventional solid-state NMR, an absolute sensitivity ratio of 24 was obtained on the entire cell sample. This important increase in sensitivity together with the possibility of enhancing specifically cell wall signals and improving resolution really opens new avenues for the use of DNP-enhanced solid-state NMR as an on-cell investigation tool. (authors)

  6. Solid-state NMR on bacterial cells: selective cell wall signal enhancement and resolution improvement using dynamic nuclear polarization.

    Science.gov (United States)

    Takahashi, Hiroki; Ayala, Isabel; Bardet, Michel; De Paëpe, Gaël; Simorre, Jean-Pierre; Hediger, Sabine

    2013-04-03

    Dynamic nuclear polarization (DNP) enhanced solid-state nuclear magnetic resonance (NMR) has recently emerged as a powerful technique for the study of material surfaces. In this study, we demonstrate its potential to investigate cell surface in intact cells. Using Bacillus subtilis bacterial cells as an example, it is shown that the polarizing agent 1-(TEMPO-4-oxy)-3-(TEMPO-4-amino)propan-2-ol (TOTAPOL) has a strong binding affinity to cell wall polymers (peptidoglycan). This particular interaction is thoroughly investigated with a systematic study on extracted cell wall materials, disrupted cells, and entire cells, which proved that TOTAPOL is mainly accumulating in the cell wall. This property is used on one hand to selectively enhance or suppress cell wall signals by controlling radical concentrations and on the other hand to improve spectral resolution by means of a difference spectrum. Comparing DNP-enhanced and conventional solid-state NMR, an absolute sensitivity ratio of 24 was obtained on the entire cell sample. This important increase in sensitivity together with the possibility of enhancing specifically cell wall signals and improving resolution really opens new avenues for the use of DNP-enhanced solid-state NMR as an on-cell investigation tool.

  7. High-resolution nuclear magnetic resonance measurements in inhomogeneous magnetic fields: A fast two-dimensional J-resolved experiment

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yuqing; Cai, Shuhui; Yang, Yu; Sun, Huijun; Lin, Yanqin, E-mail: linyq@xmu.edu.cn, E-mail: chenz@xmu.edu.cn; Chen, Zhong, E-mail: linyq@xmu.edu.cn, E-mail: chenz@xmu.edu.cn [Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005 (China); Lin, Yung-Ya [Department of Chemistry and Biochemistry, University of California, Los Angeles, California 90095 (United States)

    2016-03-14

    High spectral resolution in nuclear magnetic resonance (NMR) is a prerequisite for achieving accurate information relevant to molecular structures and composition assignments. The continuous development of superconducting magnets guarantees strong and homogeneous static magnetic fields for satisfactory spectral resolution. However, there exist circumstances, such as measurements on biological tissues and heterogeneous chemical samples, where the field homogeneity is degraded and spectral line broadening seems inevitable. Here we propose an NMR method, named intermolecular zero-quantum coherence J-resolved spectroscopy (iZQC-JRES), to face the challenge of field inhomogeneity and obtain desired high-resolution two-dimensional J-resolved spectra with fast acquisition. Theoretical analyses for this method are given according to the intermolecular multiple-quantum coherence treatment. Experiments on (a) a simple chemical solution and (b) an aqueous solution of mixed metabolites under externally deshimmed fields, and on (c) a table grape sample with intrinsic field inhomogeneity from magnetic susceptibility variations demonstrate the feasibility and applicability of the iZQC-JRES method. The application of this method to inhomogeneous chemical and biological samples, maybe in vivo samples, appears promising.

  8. Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

    International Nuclear Information System (INIS)

    Bacrania, Minesh K.; Croce, Mark; Bond, Evelyn; Dry, Donald; Moody, W. Allen; Lamont, Stephen; Rabin, Michael; Rim, Jung; Smith, Audrey; Beall, James; Bennett, Douglas; Kotsubo, Vincent; Horansky, Robert; Hilton, Gene; Schmidt, Daniel; Ullom, Joel; Cantor, Robin

    2010-01-01

    We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

  9. Monte Carlo Simulations of Ultra-High Energy Resolution Gamma Detectors for Nuclear Safeguards

    International Nuclear Information System (INIS)

    Robles, A.; Drury, O.B.; Friedrich, S.

    2009-01-01

    Ultra-high energy resolution superconducting gamma-ray detectors can improve the accuracy of non-destructive analysis for unknown radioactive materials. These detectors offer an order of magnitude improvement in resolution over conventional high purity germanium detectors. The increase in resolution reduces errors from line overlap and allows for the identification of weaker gamma-rays by increasing the magnitude of the peaks above the background. In order to optimize the detector geometry and to understand the spectral response function Geant4, a Monte Carlo simulation package coded in C++, was used to model the detectors. Using a 1 mm 3 Sn absorber and a monochromatic gamma source, different absorber geometries were tested. The simulation was expanded to include the Cu block behind the absorber and four layers of shielding required for detector operation at 0.1 K. The energy spectrum was modeled for an Am-241 and a Cs-137 source, including scattering events in the shielding, and the results were compared to experimental data. For both sources the main spectral features such as the photopeak, the Compton continuum, the escape x-rays and the backscatter peak were identified. Finally, the low energy response of a Pu-239 source was modeled to assess the feasibility of Pu-239 detection in spent fuel. This modeling of superconducting detectors can serve as a guide to optimize the configuration in future spectrometer designs.

  10. Resolution of Generic Safety Issue 29: Bolting degradation or failure in nuclear power plants

    International Nuclear Information System (INIS)

    Johnson, R.E.

    1990-06-01

    This report describes the US Nuclear Regulatory Commission's (NRC's) Generic Safety Issue 29, ''Bolting Degradation or Failure in Nuclear Power Plants,'' including the bases for establishing the issue and its historical highlights. The report also describes the activities of the Atomic Industrial Forum (AIF) relevant to this issue, including its cooperation with the Materials Properties Council (MPC) to organize a task group to help resolve the issue. The Electric Power Research Institute, supported by the AIF/MPC task group, prepared and issued a two-volume document that provides, in part, the technical basis for resolving Generic Safety Issue 29. This report presents the NRC's review and evaluation of the two-volume document and NRC's conclusion that this document, in conjunction with other information from both industry and NRC, provides the bases for resolving this issue

  11. A new scanning proton microprobe with long focus

    International Nuclear Information System (INIS)

    Zhu Jieqing; Li Minqian; Mao Yu; Chen Hanmin; Gu Yingmei; Yang Changyi; Sheng Kanglong

    1991-01-01

    A new scanning proton microprobe equipped with a long focus Russian magnetic quadruplet is set up. With excellent performances of ion optics, it can be used to do experiments of PIXE, RBS, RFS, NRA and channelling simultaneously within a micron-region. The power supplies for quadruplet and scanning coils are controlled by an IBM-PC computer and a scanning graphical monitor based on an Apple IIe microcomputer provides convenience of searching for an interesting area to scan. The advanced modes of the fast random scan and the event-by-event data collection make it possible to treat the multi-parameter and multi-detector data by means of the strategy of TQSA (Total quantitative scanning analysis). There are three types of graphical display including the innovation of three dimensional contour mapping

  12. Implementation of ionoluminescence in the AGLAE scanning external microprobe

    International Nuclear Information System (INIS)

    Pichon, L.; Calligaro, T.; Gonzalez, V.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The scope of this work is to present the implementation of an IBIL imaging system in the scanning external microprobe of the AGLAE facility so as to correlate luminescence and composition maps provided by PIXE, RBS and PIGE. The challenging integration of the optical spectrometer, due to incompatibility of acquisition timings and data formats with the other IBA channels has motivated the development of a specific acquisition system. This article details the IBIL setup and explains the technical solutions retained for the coupling of IBIL with IBA techniques in order to produce fast and large IBIL-IBA maps. The IBIL maps stored in the same format as the PIXE, RBS and PIGE ones can be visualised and compared using the dedicated AGLAEmap program or the PyMCA processing package. An example of such a coupled mapping on Mesoamerican jade is presented to emphasise the interest of performing simultaneously IBA and IBIL large mappings

  13. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    International Nuclear Information System (INIS)

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  14. Ion microprobe U-Pb dating of a dinosaur tooth

    International Nuclear Information System (INIS)

    Sano, Yuji; Terada, Kentaro; Ly, Chi V.; Park, Eun Ju

    2006-01-01

    Ion microprobe U-Pb dating of apatite is applied to a fossil tooth of a Allosaurid derived from the Hasandong Formation in the Gyeongsang basin, southeastern Korea. Twelve spots on a single fragment of the fossil dentine yield a Tera-Wasserburg concordia intercept age of 115±10 Ma (2σ, MSWD=0.59) on a 238 U/ 206 Pb- 207 Pb/ 206 Pb- 204 Pb/ 206 Pb diagram. The age provides a constraint on the depositional age of the fossil in its host Hassandong Formation as Early Aptian. The success of the ion microprobe dating depends on the heterogeneities of diagenetically incorporated U and Pb at the few hundred μm scale, the consequent variations in Pb isotopic compositions due to radioactive decay and the closed-system behavior of U and Pb. There are at least three end-members to explain the variations of minor chemical components such as FeO, SiO 2 and Al 2 O 3 , and trace elements as Th, U and rare earth elements (REE) in the sample by a simple mixing model. They are (1) very low minor and REE, very high common Pb with variable U abundances, (2) low common Pb, high minor, REE, and U abundances, and (3) low minor, common Pb, and U with intermediate REE abundances, even though groups (2) and (3) may consist of a larger group. Various contributions of the three (and/or two) end-members during diagenetic processes may cause the elemental fractionation of U and Pb in a fossil tooth. (author)

  15. Proton microprobe study of tin-polymetallic deposits

    Energy Technology Data Exchange (ETDEWEB)

    Murao, S. [Geological Survey of Japan, Tsukuba, Ibaraki (Japan); Sie, S.H.; Suter, G.F. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1996-12-31

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs.

  16. Proton microprobe study of tin-polymetallic deposits

    Energy Technology Data Exchange (ETDEWEB)

    Murao, S [Geological Survey of Japan, Tsukuba, Ibaraki (Japan); Sie, S H; Suter, G F [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1997-12-31

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs.

  17. Proton microprobe study of tin-polymetallic deposits

    International Nuclear Information System (INIS)

    Murao, S.; Sie, S.H.; Suter, G.F.

    1996-01-01

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs

  18. Application of PIXE analysis to environmental samples stable element distribution in sea algae by scanning microprobe analysis

    International Nuclear Information System (INIS)

    Ishikawa, M.; Kitao, K.; Imaseki, H.; Ishii, T.; Uchida, S.

    1984-01-01

    The resolution of a 33+-3 μm microprobe focussed with quadrupole doublet installed at the 3 MV Van de Graaff of the National Institute of Radiological Sciences, Japan, was used for the present analysis. Brown algae, Hizikia fusiforme was the sample target bombarded with a 2 MeV proton beam collimated mechanically into a rectangular image of 100 μm x 700 μm. Scanning across the sample target prepared into a longitudinal section from the caulis of the algae provided the following observations. More than 12 elements such as Al, Si, P, Cl, Ca, Mn, Fe, Cu, Zn, As, Br and Sr were determined simultaneously, together with their distributional information across the diameter. In the medullary layer, Mn and Zn were specific in their accumulation, while the deposition of Fe, Cu, As and Br were observed to be high in the epithelial layer, especially Fe and Cu which were found on the surface, where they contacted ambient sea water, but no significant change in pattern was indicated for such elements as Al, P and Cl. The PIXE microprobe analysis was, therefore, effective in its detectability for elements below a few ppm level, resultantly providing further possibilities for collecting information from bio-medical and environmental samples on trace characterization of elements. (author)

  19. Use of a synchrotron radiation x-ray microprobe for elemental analysis at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Gordon, B.M.

    1980-01-01

    The National Synchrotron Light Source (NSLS) is a facility consisting of a 700 MeV and a 2.5 GeV electron storage ring and dedicated to providing synchrotron radiation in the energy range from the vacuum ultraviolet to high energy x rays. Some of the properties of synchrotron radiation that contribute to its usefulness for x-ray fluorescence are: a continuous, tunable energy spectrum, strong collimation in the horizontal plane, high polarization in the storage ring plane, and relatively low energy deposition. The highest priority is for the development of an x-ray microprobe beam line capable of trace analysis in the parts per million range with spatial resolution as low as one micrometer. An eventual capability for bulk sample analysis is also planned with sensitivities in the more favorable cases beings low as 50 parts per billion in dry biological tissue. The microprobe technique has application to a variety of fields including the geological, medical, materials and environmental sciences. Examples of investigations include multielemental trace analysis across grain boundaries for the study of diffusion and cooling processes in geological and materials sciences samples; in leukocytes and other types of individual cells for studying the relationship between trace element concentrations and disease or nutrition; and in individual particles in air pollution samples

  20. Quantification and localization of trace metals in natural plankton using a synchrotron x-ray fluorescence microprobe

    International Nuclear Information System (INIS)

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Jacobsen, C.; Maser, J.; State Univ. of New York at Stony Brook

    2003-01-01

    The accumulation of trace metals by planktonic protists influences the growth of primary producers, metal biogeochemical cycling, and metal bioaccumulation in aquatic food chains. Despite their importance, unequivocal measurements of trace element concentrations in individual plankton cells have not been possible to date. We have used the 2-ID-E side-branch hard x-ray microprobe at the Advanced Photon Source to measure trace elements in individual marine plankton cells. This microprobe employs zoneplate optics to produce the sub-micron spatial resolution and low background fluorescence required to produce trace element maps of planktonic protist cells ranging in size from 3 to >50 (micro)m. We have developed preservation, rinsing, and mounting protocols that remove most of the salt from our marine samples, thus simplifying the identification of unknown cells and reducing high Cl-related background fluorescence. We have also developed spectral modeling techniques that account for the frequent overlap of adjacent fluorescence peaks and non-uniform detector response. Finally, we have used parallel soft x-ray transmission and epifluorescence microscopy images to estimate C normalized trace element concentrations, identify functional cell types (e.g., photosynthetic vs. non-photosynthetic), and correlate cell structures with spatial patterns in trace element fluorescence

  1. Quantification and localization of trace metals in natural plancton using a synchrotron x-ray fluorescence microprobe.

    Energy Technology Data Exchange (ETDEWEB)

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Jacobsen, C.; Maser, J.; State Univ. of New York at Stony Brook

    2003-03-01

    The accumulation of trace metals by planktonic protists influences the growth of primary producers, metal biogeochemical cycling, and metal bioaccumulation in aquatic food chains. Despite their importance, unequivocal measurements of trace element concentrations in individual plankton cells have not been possible to date. We have used the 2-ID-E side-branch hard x-ray microprobe at the Advanced Photon Source to measure trace elements in individual marine plankton cells. This microprobe employs zoneplate optics to produce the sub-micron spatial resolution and low background fluorescence required to produce trace element maps of planktonic protist cells ranging in size from 3 to >50 {micro}m. We have developed preservation, rinsing, and mounting protocols that remove most of the salt from our marine samples, thus simplifying the identification of unknown cells and reducing high Cl-related background fluorescence. We have also developed spectral modeling techniques that account for the frequent overlap of adjacent fluorescence peaks and non-uniform detector response. Finally, we have used parallel soft x-ray transmission and epifluorescence microscopy images to estimate C normalized trace element concentrations, identify functional cell types (e.g., photosynthetic vs. non-photosynthetic), and correlate cell structures with spatial patterns in trace element fluorescence.

  2. High-resolution autoradiography of nuclear modifications during and after heat treatment of neurospora crassa

    International Nuclear Information System (INIS)

    Ton-That, C.; Turian, G.

    1984-01-01

    The appearance of perinucleolar electron-dense spots in the nuclei of macroconidia of Neurospora crassa incubated at 46 0 C and their disaggregation after shift-down to 25 0 C have been investigated by high-resolution autoradiography after (5- 3 H) uridine pulses with or without chase periods. The RNA of these ribonucleoprotein-rich dense spots has been found to originate mainly from the heat-sensitive nucleolus; after return to 25 0 C, the nucleolar activity was recovered and the RNA material stored either in an unprocessed or a mature rRNA form in the dense spots was found to be progressively extruded into the cytoplasm. (Author)

  3. A simple pulsed drain feedback preamplifier for high resolution high rate nuclear spectroscopy

    International Nuclear Information System (INIS)

    Lakatos, T.; Hegyesi, G.; Kalinka, G.

    1996-01-01

    A non-optical, pulsed reset technique for use in charge sensitive preamplifiers with Si(Li) X-ray semiconductor detectors of conventional polarity is described. The phenomenon of impact ionization in the field effect transistor is used for charge restoration. The process is controlled via the detector capacitance. The method needs no extra components in the input circuitry. No significant resolution degradation can be detected up to 600 kcps Mn K intensity if following the 5 μs resetting pulse the signal processor is inhibited for 50 μs. (orig.)

  4. A simple pulsed drain feedback preamplifier for high resolution high rate nuclear spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lakatos, T. [Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete; Hegyesi, G. [Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete; Kalinka, G. [Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete

    1996-08-21

    A non-optical, pulsed reset technique for use in charge sensitive preamplifiers with Si(Li) X-ray semiconductor detectors of conventional polarity is described. The phenomenon of impact ionization in the field effect transistor is used for charge restoration. The process is controlled via the detector capacitance. The method needs no extra components in the input circuitry. No significant resolution degradation can be detected up to 600 kcps Mn K intensity if following the 5 {mu}s resetting pulse the signal processor is inhibited for 50 {mu}s. (orig.).

  5. Resolution Improvement in Multidimensional Nuclear Magnetic Resonance Spectroscopy of Proteins; Amelioration de la resolution dans la resonance magnetique nucleaire multidimensionnelle des proteines

    Energy Technology Data Exchange (ETDEWEB)

    Duma, L

    2004-07-01

    The work presented in this thesis is concerned with both liquid-state and solid-state nuclear magnetic resonance (NMR) spectroscopy. Most of this work is devoted to the investigation by solid-state NMR of C{sup 13}-enriched compounds with the principal aim of presenting techniques devised for further improving the spectral resolution in multidimensional NMR of microcrystalline proteins. In fully C{sup 13}-labelled compounds, the J-coupling induces a broadening of the carbon lineshapes. We show that spin-state-selective technique called IPAP can be successfully combined with standard polarisation transfer schemes in order to remove the J-broadening in multidimensional solid-state NMR correlation experiments of fully C{sup 13}-enriched proteins. We present subsequently two techniques tailored for liquid-state NMR spectroscopy. The carbon directly detected techniques provide chemical shift information for all backbone hetero-nuclei. They are very attracting for the study of large bio-molecular systems or for the investigation of paramagnetic proteins. In the last part of this thesis, we study the spin-echo J-modulation for homonuclear two-spin 1/2 systems. Under magic-angle spinning, the theory of J-induced spin-echo modulation allows to derive a set of modulation regimes which give a spin-echo modulation exactly equal to the J-coupling. We show that the chemical-shift anisotropy and the dipolar interaction tend to stabilize the spin-echo J-modulation. The theoretical conclusions are supported by numerical simulations and experimental results obtained for three representative samples containing C{sup 13} spin pairs. (author)

  6. Nuclear structure at the limits of resolution: Looking through individual wave functions

    Energy Technology Data Exchange (ETDEWEB)

    Zelevinsky, V.G. [Michigan State Univ., East Lansing, MI (United States)

    1996-12-31

    60 years ago Niels Bohr suggested the idea of the compound nucleus. Bohr`s picture strongly resembles that of quantum chaos. Here one comes to the limits of resolution studying particular stationary states at high level density. Present knowledge comes from the experiment and from theoretical constructions, confirmed by the experiment at lower energies and extrapolated into the region where fine resolution measurements are not feasible. Such an analysis was carried out recently for heavy atoms and shell model nuclei. Among complicated states with the same values of integrals of motion, either (i) adjacent states have different structure or (ii) they {open_quotes}look the same{close_quotes} on the microscopic scale. Only (ii) corresponds to strong mixing assumed in the compound nucleus theory. Many-body chaos in nuclei is caused by residual interactions rather than by specific shape of the {open_quotes}container{close_quotes} as in quantum billiards. The shell model, including all degrees of freedom (in truncated space) along with the symmetry requirements, guarantees the correct level density up to some excitation energy. Therefore one can extrapolate the calculations into terra incognita of high lying states.

  7. The optimization of the time resolution and the sensitivity in the pulsed nuclear resonance

    International Nuclear Information System (INIS)

    Umathum, R.

    1987-01-01

    The time resolution of pulsed NMR spectrometer and its spectral sensitivity are closely connected together. An important obstacle in the attempt to increase the resolution represents the dead time of the spectrometer. In the present thesis therefore the different contributions to the system dead time and their causes are analyzed and ways to the reduction respectively complete removement of a part of these contributions are indicated. So a duplexer was developed and constructed on the base of a principle novel for the NMR under application of quadrature hybrids which reduces the residual voltage of the sender pulse to less than 1/10 of the hitherto reached value. In this thesis a concept is extensively discussed which allows to generate at constant quality respectively damping constant of the sample circuit and given sender power a larger high frequency field strength than it is possible in the state of the power fitting. It could be shown than also concerning the noise behaviour by the application of the principle of the defined misfit no compromise must be made but it is even facilitated to approach the ideal of the noise fit of the first receiver stage to the sample circuit. (orig./HSI) [de

  8. Nuclear forensic applications involving high spatial resolution analysis of Trinitite cross-sections

    International Nuclear Information System (INIS)

    Donohue, P.H.; Antonio Simonetti; Koeman, E.C.; Sara Mana; University of Iowa, Iowa City, IA; Burns, P.C.; University of Notre Dame, Notre Dame, IN

    2015-01-01

    This study reports a comprehensive cross-sectional analysis of major and trace element abundances and 240 Pu/ 239 Pu ratios within vertically oriented Trinitite thin sections. The upper glassy layer (∼2 mm thick) represents fused desert sand combined with devolatilized fallout from the debris cloud. The vertical distribution of 240 Pu/ 239 Pu ratios indicates that residual fuel was incorporated deeper (up to ∼10 mm depth) into Trinitite than previously reported. This requires thorough mixing and disturbance of the upper cm of the blast site prior to or during the initial melting of the desert sand resulting from the nuclear explosion. (author)

  9. The Highest Resolution Chandra View of Photoionization and Jet-Cloud Interaction in the Nuclear Region of NGC 4151

    Science.gov (United States)

    Wang, Junfeng; Fabbiano, G.; Karovska, M.; Elvis, M.; Risaliti, G.; Zezas, A.; Mundell, C. G.

    2009-10-01

    We report high resolution imaging of the nucleus of the Seyfert 1 galaxy NGC 4151 obtained with a 50 ks Chandra High Resolution Camera (HRC) observation. The HRC image resolves the emission on spatial scales of 0farcs5, ~30 pc, showing an extended X-ray morphology overall consistent with the narrow-line region (NLR) seen in optical line emission. Removal of the bright point-like nuclear source and image deconvolution techniques both reveal X-ray enhancements that closely match the substructures seen in the Hubble Space Telescope [O III] image and prominent knots in the radio jet. We find that most of the NLR clouds in NGC 4151 have [O III]/soft X-ray ratio ~10, despite the distance of the clouds from the nucleus. This ratio is consistent with the values observed in NLRs of some Seyfert 2 galaxies, which indicates a uniform ionization parameter even at large radii and a density decreasing as r -2 as expected for a nuclear wind scenario. The [O III]/X-ray ratios at the location of radio knots show an excess of X-ray emission, suggesting shock heating in addition to photoionization. We examine various mechanisms for the X-ray emission and find that, in contrast to jet-related X-ray emission in more powerful active galactic nucleus, the observed jet parameters in NGC 4151 are inconsistent with synchrotron emission, synchrotron self-Compton, inverse Compton of cosmic microwave background photons or galaxy optical light. Instead, our results favor thermal emission from the interaction between radio outflow and NLR gas clouds as the origin for the X-ray emission associated with the jet. This supports previous claims that frequent jet-interstellar medium interaction may explain why jets in Seyfert galaxies appear small, slow, and thermally dominated, distinct from those kpc-scale jets in the radio galaxies.

  10. THE HIGHEST RESOLUTION CHANDRA VIEW OF PHOTOIONIZATION AND JET-CLOUD INTERACTION IN THE NUCLEAR REGION OF NGC 4151

    International Nuclear Information System (INIS)

    Wang Junfeng; Fabbiano, G.; Karovska, M.; Elvis, M.; Risaliti, G.; Zezas, A.; Mundell, C. G.

    2009-01-01

    We report high resolution imaging of the nucleus of the Seyfert 1 galaxy NGC 4151 obtained with a 50 ks Chandra High Resolution Camera (HRC) observation. The HRC image resolves the emission on spatial scales of 0.''5, ∼30 pc, showing an extended X-ray morphology overall consistent with the narrow-line region (NLR) seen in optical line emission. Removal of the bright point-like nuclear source and image deconvolution techniques both reveal X-ray enhancements that closely match the substructures seen in the Hubble Space Telescope [O III] image and prominent knots in the radio jet. We find that most of the NLR clouds in NGC 4151 have [O III]/soft X-ray ratio ∼10, despite the distance of the clouds from the nucleus. This ratio is consistent with the values observed in NLRs of some Seyfert 2 galaxies, which indicates a uniform ionization parameter even at large radii and a density decreasing as r -2 as expected for a nuclear wind scenario. The [O III]/X-ray ratios at the location of radio knots show an excess of X-ray emission, suggesting shock heating in addition to photoionization. We examine various mechanisms for the X-ray emission and find that, in contrast to jet-related X-ray emission in more powerful active galactic nucleus, the observed jet parameters in NGC 4151 are inconsistent with synchrotron emission, synchrotron self-Compton, inverse Compton of cosmic microwave background photons or galaxy optical light. Instead, our results favor thermal emission from the interaction between radio outflow and NLR gas clouds as the origin for the X-ray emission associated with the jet. This supports previous claims that frequent jet-interstellar medium interaction may explain why jets in Seyfert galaxies appear small, slow, and thermally dominated, distinct from those kpc-scale jets in the radio galaxies.

  11. Low energy nuclear spin excitations in Ho metal investigated by high resolution neutron spectroscopy.

    Science.gov (United States)

    Chatterji, Tapan; Jalarvo, Niina

    2013-04-17

    We have investigated the low energy excitations in metallic Ho by high resolution neutron spectroscopy. We found at T = 3 K clear inelastic peaks in the energy loss and energy gain sides, along with the central elastic peak. The energy of this low energy excitation, which is 26.59 ± 0.02 μeV at T = 3 K, decreased continuously and became zero at TN ≈ 130 K. By fitting the data in the temperature range 100-127.5 K with a power law we obtained the power-law exponent β = 0.37 ± 0.02, which agrees with the expected value β = 0.367 for a three-dimensional Heisenberg model. Thus the energy of the low energy excitations can be associated with the order parameter.

  12. High-resolution autoradiography of nuclear modifications during and after heat treatment of neurospora crassa

    Energy Technology Data Exchange (ETDEWEB)

    Ton-That, C.; Turian, G. (Geneva Univ. (Switzerland))

    1984-01-01

    The appearance of perinucleolar electron-dense spots in the nuclei of macroconidia of Neurospora crassa incubated at 46/sup 0/C and their disaggregation after shift-down to 25/sup 0/C have been investigated by high-resolution autoradiography after (5-/sup 3/H) uridine pulses with or without chase periods. The RNA of these ribonucleoprotein-rich dense spots has been found to originate mainly from the heat-sensitive nucleolus; after return to 25/sup 0/C, the nucleolar activity was recovered and the RNA material stored either in an unprocessed or a mature rRNA form in the dense spots was found to be progressively extruded into the cytoplasm.

  13. Direct localised measurement of electrical resistivity profile in rat and embryonic chick retinas using a microprobe

    Directory of Open Access Journals (Sweden)

    Harald van Lintel

    2010-01-01

    Full Text Available We report an alternative technique to perform a direct and local measurement of electrical resistivities in a layered retinal tissue. Information on resistivity changes along the depth in a retina is important for modelling retinal stimulation by retinal prostheses. Existing techniques for resistivity-depth profiling have the drawbacks of a complicated experimental setup, a less localised resistivity probing and/or lower stability for measurements. We employed a flexible microprobe to measure local resistivity with bipolar impedance spectroscopy at various depths in isolated rat and chick embryo retinas for the first time. Small electrode spacing permitted high resolution measurements and the probe flexibility contributed to stable resistivity profiling. The resistivity was directly calculated based on the resistive part of the impedance measured with the Peak Resistance Frequency (PRF methodology. The resistivity-depth profiles for both rat and chick embryo models are in accordance with previous mammalian and avian studies in literature. We demonstrate that the measured resistivity at each depth has its own PRF signature. Resistivity profiles obtained with our setup provide the basis for the construction of an electric model of the retina. This model can be used to predict variations in parameters related to retinal stimulation and especially in the design and optimisation of efficient retinal implants.

  14. Metallographic study of ferrite → sigma transformation using ferromagnetic colloid, microprobe analysis, and color etching

    International Nuclear Information System (INIS)

    Gray, R.J.; Crouse, R.S.; Sikka, V.K.; King, R.T.

    1976-01-01

    The mechanical properties of ferrite-containing austenitic stainless steel base metal and weldments are usually adversely affected by prolonged exposure to temperatures in the 482-900 0 C (900-1652 0 F) range. One cause of the property alteration is related to the transformation of relatively ductile delta-ferrite to less ductile sigma-phase. Attempts to identify sigma and delta ferrite phases by color staining techniques alone are well documented; however, the results are often questionable due to the difficulty in maintaining consistent color identifications. This investigation is concerned with the microstructural responses of the ferromagnetic delta-ferrite phase and the paramagnetic sigma-phase to a ferromagnetic iron colloid in a magnetic field. Such positive or negative responses of the two phases to the colloid offer a more definitive identification. With this technique, the identification of small amounts of these phases in the microstructure is limited only by the highest magnification and resolution of the optical microscope. The procedure is substantiated in this metallographic study with microprobe analysis and color metallography. Several examples of the correlative use of these three techniques in identifying varying amounts of delta-ferrite yields sigma transformation are presented

  15. High-resolution coupled physics solvers for analysing fine-scale nuclear reactor design problems

    Science.gov (United States)

    Mahadevan, Vijay S.; Merzari, Elia; Tautges, Timothy; Jain, Rajeev; Obabko, Aleksandr; Smith, Michael; Fischer, Paul

    2014-01-01

    An integrated multi-physics simulation capability for the design and analysis of current and future nuclear reactor models is being investigated, to tightly couple neutron transport and thermal-hydraulics physics under the SHARP framework. Over several years, high-fidelity, validated mono-physics solvers with proven scalability on petascale architectures have been developed independently. Based on a unified component-based architecture, these existing codes can be coupled with a mesh-data backplane and a flexible coupling-strategy-based driver suite to produce a viable tool for analysts. The goal of the SHARP framework is to perform fully resolved coupled physics analysis of a reactor on heterogeneous geometry, in order to reduce the overall numerical uncertainty while leveraging available computational resources. The coupling methodology and software interfaces of the framework are presented, along with verification studies on two representative fast sodium-cooled reactor demonstration problems to prove the usability of the SHARP framework. PMID:24982250

  16. Nuclear graphite development, operational problems, and resolution of these problems at the Hanford production reactors

    International Nuclear Information System (INIS)

    Morgan, W.C.

    1996-01-01

    This paper chronicles the history of the Hanford Production Reactor, from the initial design considerations for B, D, and F Reactors through the selection of the agreed method for safe disposal of the decommissioned reactors. The operational problems that challenged the operations and support staff of each new generation of production reactors, the engineering actions an operational changes that alleviated or resolved the immediate problems, the changes in reactor design and design-bases for the next generation of production reactors, and the changes in manufacturing variables that resulted in new ''improved'' grades of nuclear graphites for use in the moderators of the Hanford Production Reactors are reviewed in the context of the existing knowledge-base and the mission-driven priorities on the time. 14 refs, 6 figs, 3 tabs

  17. Neutron irradiation damage of nuclear graphite studied by high-resolution transmission electron microscopy and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, R. [Dalton Cumbrian Facility, Dalton Nuclear Institute, The University of Manchester, Westlakes Science & Technology Park, Moor Row, Whitehaven, Cumbria, CA24 3HA (United Kingdom); Jones, A.N., E-mail: Abbie.Jones@manchester.ac.uk [Nuclear Graphite Research Group, School of MACE, The University of Manchester, Manchester, M13 9PL (United Kingdom); McDermott, L.; Marsden, B.J. [Nuclear Graphite Research Group, School of MACE, The University of Manchester, Manchester, M13 9PL (United Kingdom)

    2015-12-15

    Nuclear graphite components are produced from polycrystalline artificial graphite manufacture from a binder and filler coke with approximately 20% porosity. During the operational lifetime, nuclear graphite moderator components are subjected to fast neutron irradiation which contributes to the change of material and physical properties such as thermal expansion co-efficient, young's modulus and dimensional change. These changes are directly driven by irradiation-induced changes to the crystal structure as reflected through the bulk microstructure. It is therefore of critical importance that these irradiation changes and there implication on component property changes are fully understood. This work examines a range of irradiated graphite samples removed from the British Experimental Pile Zero (BEPO) reactor; a low temperature, low fluence, air-cooled Materials Test Reactor which operated in the UK. Raman spectroscopy and high-resolution transmission electron microscopy (HRTEM) have been employed to characterise the effect of increased irradiation fluence on graphite microstructure and understand low temperature irradiation damage processes. HRTEM confirms the structural damage of the crystal lattice caused by irradiation attributed to a high number of defects generation with the accumulation of dislocation interactions at nano-scale range. Irradiation-induced crystal defects, lattice parameters and crystallite size compared to virgin nuclear graphite are characterised using selected area diffraction (SAD) patterns in TEM and Raman Spectroscopy. The consolidated ‘D’peak in the Raman spectra confirms the formation of in-plane point defects and reflected as disordered regions in the lattice. The reduced intensity and broadened peaks of ‘G’ and ‘D’ in the Raman and HRTEM results confirm the appearance of turbulence and disordering of the basal planes whilst maintaining their coherent layered graphite structure. - Highlights: • Irradiated graphite

  18. Neutron irradiation damage of nuclear graphite studied by high-resolution transmission electron microscopy and Raman spectroscopy

    International Nuclear Information System (INIS)

    Krishna, R.; Jones, A.N.; McDermott, L.; Marsden, B.J.

    2015-01-01

    Nuclear graphite components are produced from polycrystalline artificial graphite manufacture from a binder and filler coke with approximately 20% porosity. During the operational lifetime, nuclear graphite moderator components are subjected to fast neutron irradiation which contributes to the change of material and physical properties such as thermal expansion co-efficient, young's modulus and dimensional change. These changes are directly driven by irradiation-induced changes to the crystal structure as reflected through the bulk microstructure. It is therefore of critical importance that these irradiation changes and there implication on component property changes are fully understood. This work examines a range of irradiated graphite samples removed from the British Experimental Pile Zero (BEPO) reactor; a low temperature, low fluence, air-cooled Materials Test Reactor which operated in the UK. Raman spectroscopy and high-resolution transmission electron microscopy (HRTEM) have been employed to characterise the effect of increased irradiation fluence on graphite microstructure and understand low temperature irradiation damage processes. HRTEM confirms the structural damage of the crystal lattice caused by irradiation attributed to a high number of defects generation with the accumulation of dislocation interactions at nano-scale range. Irradiation-induced crystal defects, lattice parameters and crystallite size compared to virgin nuclear graphite are characterised using selected area diffraction (SAD) patterns in TEM and Raman Spectroscopy. The consolidated ‘D’peak in the Raman spectra confirms the formation of in-plane point defects and reflected as disordered regions in the lattice. The reduced intensity and broadened peaks of ‘G’ and ‘D’ in the Raman and HRTEM results confirm the appearance of turbulence and disordering of the basal planes whilst maintaining their coherent layered graphite structure. - Highlights: • Irradiated graphite exhibits

  19. Raman and luminescence spectroscopy of zirconium oxide with the use of the MOLE microprobe

    International Nuclear Information System (INIS)

    Doyle, T.E.; Alvarez, J.L.

    1984-01-01

    Raman and luminescence spectroscopy with the use of the MOLE microprobe has been used to characterize ZrO 2 originating from oxidized fuel-rod cladding in nuclear accidents. Micro-Raman analysis of samples from Three Mile Island Unit 2 and the Power Burst Facility identified tetragonal and cubic ZrO 2 . The tetragonal and cubic phases are high-temperature polymorphs of ZrO 2 and provide information about temperatures and hydrogen formation in the TMI-2 core. The data suggest that the tetragonal ZrO 2 in TMI-2 samples was stabilized by a crystallite size effect, whereas cubic ZrO 2 in PBF debris samples was stabilized by impurities. Luminescence was used to differentiate yttria-stabilized ZrO 2 ceramics and oxidized fuel-rod cladding in PBF debris samples. The ZrO 2 ceramics produced strong, sharp luminescence peaks which indicated the presence of titanium and yttria in the ZrO 2 . Oxidized fuel-rod cladding displayed no luminescence

  20. Microprobe PIXE study of Ni–Ge interactions in lateral diffusion couples

    Energy Technology Data Exchange (ETDEWEB)

    Chilukusha, D. [Department of Physics, University of Zambia, P.O. Box 32379, Lusaka 10101 (Zambia); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Faculty of Health & Wellness Sciences, CPUT, Bellville (South Africa); Nemutudi, R. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Habanyama, A. [Department of Physics, Copperbelt University, P.O. Box 21692, Jambo Drive, Riverside, Kitwe 10101 (Zambia); Comrie, C.M. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa)

    2015-11-15

    Rutherford backscattering spectrometry on the nuclear microprobe (μRBS) is often used in studies of lateral diffusion couples. RBS requires that the positions of the interacting species on the periodic table are not too close in terms of atomic number and therefore do not produce excessive RBS peak overlap. In order to satisfactorily characterize systems that have atomic numbers which are close, it is necessary to find techniques which can complement μRBS. The aim of this study was to determine the extent to which particle induced X-ray emission (PIXE) could be applied in the lateral diffusion couple study of a system with relatively close atomic numbers. This was with a view that it may eventually be adopted to study systems where the atomic numbers are too close for RBS analysis. The system studied here was the Ni–Ge binary system. Since RBS is an established technique for studying lateral diffusion couples, we used it as a standard for comparison. The PIXE results showed a maximum error of 12% with reference to the RBS standard. In order to achieve the most effective use of PIXE in lateral diffusion couple studies we recommend the use of the technique in such a way as to obtain depth information and the use of relatively thick sample layers.

  1. NENIMF: Northeast National Ion Microprobe Facility - A Multi-User Facility for SIMS Microanalysis

    Science.gov (United States)

    Layne, G. D.; Shimizu, N.

    2002-12-01

    The MIT-Brown-Harvard Regional Ion Microprobe Facility was one of the earliest multi-user facilities enabled by Dan Weill's Instrumentation and Facilities Program - and began with the delivery of a Cameca IMS 3f ion microprobe to MIT in 1978. The Northeast National Ion Microprobe Facility (NENIMF) is the direct descendant of this original facility. Now housed at WHOI, the facility incorporates both the original IMS 3f, and a new generation, high transmission-high resolution instrument - the Cameca IMS 1270. Purchased with support from NSF, and from a consortium of academic institutions in the Northeast (The American Museum of Natural History, Brown University, The Lamont-Doherty Earth Observatory, MIT, Rensselaer Polytechnic Institute, WHOI) - this latest instrument was delivered and installed during 1996. NENIMF continues to be supported by NSF EAR I&F as a multi-user facility for geochemical research. Work at NENIMF has extended the original design strength of the IMS 1270 for microanalytical U-Pb zircon geochronology to a wide variety of novel and improved techniques for geochemical research. Isotope microanalysis for studies in volcanology and petrology is currently the largest single component of facility activity. This includes the direct measurement of Pb isotopes in melt inclusions, an application developed at NENIMF, which is making an increasingly significant contribution to our understanding of basalt petrogenesis. This same technique has also been extended to the determination of Pb isotopes in detrital feldspar grains, for the study of sedimentary provenance and tectonics of the Himalayas and other terrains. The determination of δ11B in volcanic melt inclusions has also proven to be a powerful tool in the modeling of subduction-related magmatism. The recent development of δ34S and δ37Cl determination in glasses is being applied to studies of the behavior of these volatile elements in both natural and experimental systems. Other recent undertakings

  2. Long-term millimeter VLBI monitoring of M 87 with KVN at milliarcsecond resolution: nuclear spectrum

    Science.gov (United States)

    Kim, Jae-Young; Lee, Sang-Sung; Hodgson, Jeffrey A.; Algaba, Juan-Carlos; Zhao, Guang-Yao; Kino, Motoki; Byun, Do-Young; Kang, Sincheol

    2018-02-01

    We study the centimeter- to millimeter-wavelength synchrotron spectrum of the core of the radio galaxy M 87 at ≲0.8 mas 110Rs spatial scales using four years of fully simultaneous, multi-frequency VLBI data obtained by the Korean VLBI Network (KVN). We find a core spectral index α of ≳‑0.37 (S ∝ ν+α) between 22 and 129 GHz. By combining resolution-matched flux measurements from the Very Long Baseline Array (VLBA) at 15 GHz and taking the Event Horizon Telescope (EHT) 230 GHz core flux measurements in epochs 2009 and 2012 as lower limits, we find evidence of a nearly flat core spectrum across 15 and 129 GHz, which could naturally connect the 230 GHz VLBI core flux. The extremely flat spectrum is a strong indication that the jet base does not consist of a simple homogeneous plasma, but of inhomogeneous multi-energy components, with at least one component with the turn-over frequency ≳ 100 GHz. The spectral shape can be qualitatively explained if both the strongly (compact, optically thick at >100 GHz) and the relatively weakly magnetized (more extended, optically thin at <100 GHz) plasma components are colocated in the footprint of the relativistic jet.

  3. High-resolution nuclear magnetic resonance of quadrupolar nuclei in solids

    International Nuclear Information System (INIS)

    Charpentier, Th.

    1998-01-01

    After a brief review of existing methods in high-resolution NMR of quadrupolar nuclei, the manipulation of multi-quantum coherencies by radiofrequency pulses is studied. Results are then applied to the determination of optimal conditions for performing the recently introduced multiple-quantum magic-angle experiment (MQMAS). The principles of this new method, the different pulse sequences and the data processing are described in detail. Applications on aluminum hydrates and cement pastes show the improvements of this new technique over the previous ones. In a second part, after an investigation of the Floquet theory, a new formalism has been devised for studying the behavior of a spin submitted to a strong quadrupolar interaction and radiofrequency field in a rotating sample. This formalism is then applied to a quantitative study of the phenomenon of rotational induced adiabatic transfer of coherencies (RIACT). The extension of our theoretical approach to two-dimensional experiments provides a powerful tool for quantitative analyses of MQMAS spectra. Agreement between experimental data and simulations demonstrates the reliability of our approach. Preliminary results concerning the application of MQMAS spectroscopy, using our simulation programs, to structural study of amorphous materials are presented. The third and last part presents a theoretical and experimental investigation of dipolar order in a rotating sample. Two theoretical models are described, the first for the slow spinning speed regime where an adiabatic approximation can be made, and the second for the fast spinning speed regime. (author)

  4. Examination of Laser Microprobe Vacuum Ultraviolet Ionization Mass Spectrometry with Application to Mapping Mars Returned Samples

    Science.gov (United States)

    Burton, A. S.; Berger, E. L.; Locke, D. R.; Lewis, E. K.; Moore, J. F.

    2018-04-01

    Laser microprobe of surfaces utilizing a two laser setup whereby the desorption laser threshold is lowered below ionization, and the resulting neutral plume is examined using 157nm Vacuum Ultraviolet laser light for mass spec surface mapping.

  5. Laser microprobe for the study of noble gases and nitrogen in single ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Planetary and Geosciences Division, Physical Research Laboratory, Ahmedabad 380 009, India. ∗e-mail: murty@prl.ernet.in. A laser microprobe capable of analysing nitrogen and noble gases in .... tion properties for light radiation, with some.

  6. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Yumoto, S.; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-01-01

    To investigate the cause of Alzheimer's disease (senile dementia of Alzheimer's disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer's disease using heavy ion (5 MeV Si 3+ ) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si 2+ ) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer's disease using 5 MeV Si 3+ microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer's disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  7. HIGH-RESOLUTION RADIO CONTINUUM MEASUREMENTS OF THE NUCLEAR DISKS OF Arp 220

    Energy Technology Data Exchange (ETDEWEB)

    Barcos-Muñoz, L.; Evans, A. S.; Privon, G. C.; Stierwalt, S. [Department of Astronomy, University of Virginia, 530 McCormick Road, Charlottesville, VA 22904 (United States); Leroy, A. K.; Condon, J.; Reichardt, A. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22904 (United States); Armus, L. [Spitzer Science Center, California Institute of Technology, MC 220-6, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Mazzarella, J. M.; Murphy, E. J. [Infrared Processing and Analysis Center, MS 100-22, California Institute of Technology, Pasadena, CA 91125 (United States); Meier, D. S. [New Mexico Institute of Mining and Technology, 801 Leroy Place, Socorro, NM 87801 (United States); Momjian, E.; Ott, J. [National Radio Astronomy Observatory, P.O. Box O, 1003 Lopezville Road, Socorro, NM 87801 (United States); Sakamoto, K. [Academia Sinica, Institute of Astronomy and Astrophysics, P.O. Box 23-141, Taipei 10617, Taiwan (China); Sanders, D. B. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96816 (United States); Schinnerer, E.; Walter, F. [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Surace, J. A. [Spitzer Science Center, MS 314-6, California Institute of Technology, Pasadena, CA 91125 (United States); Thompson, T. A., E-mail: ldb7et@virginia.edu [Department of Astronomy and Center for Cosmology and Astro-Particle Physics, The Ohio State University, Columbus, OH 43210 (United States)

    2015-01-20

    We present new Karl G. Jansky Very Large Array radio continuum images of the nuclei of Arp 220, the nearest ultra-luminous infrared galaxy. These new images have both the angular resolution to study the detailed morphologies of the two nuclei that power the galaxy merger and sensitivity to a wide range of spatial scales. At 33 GHz, we achieve a resolution of 0.''081 × 0.''063 (29.9 × 23.3 pc) and resolve the radio emission surrounding both nuclei. We conclude from the decomposition of the radio spectral energy distribution that a majority of the 33 GHz emission is synchrotron radiation. The spatial distributions of radio emission in both nuclei are well described by exponential profiles. These have deconvolved half-light radii (R {sub 50d}) of 51 and 35 pc for the eastern and western nuclei, respectively, and they match the number density profile of radio supernovae observed with very long baseline interferometry. This similarity might be due to the fast cooling of cosmic rays electrons caused by the presence of a strong (∼mG) magnetic field in this system. We estimate extremely high molecular gas surface densities of 2.2{sub −1.0}{sup +2.1}×10{sup 5} (east) and 4.5{sub −1.9}{sup +4.5}×10{sup 5} (west) M {sub ☉} pc{sup –2}, corresponding to total hydrogen column densities of N {sub H} = 2.7{sub −1.2}{sup +2.7}×10{sup 25} (east) and 5.6{sub −2.4}{sup +5.5}×10{sup 25} cm{sup –2} (west). The implied gas volume densities are similarly high, n{sub H{sub {sub 2}}}∼3.8{sub −1.6}{sup +3.8}×10{sup 4} (east) and ∼11{sub −4.5}{sup +12}×10{sup 4} cm{sup –3} (west). We also estimate very high luminosity surface densities of Σ{sub IR}∼4.2{sub −0.7}{sup +1.6}×10{sup 13} (east) and Σ{sub IR}∼9.7{sub −2.4}{sup +3.7}×10{sup 13} (west) L{sub ⊙} kpc{sup −2}, and star formation rate surface densities of Σ{sub SFR} ∼ 10{sup 3.7} {sup ±} {sup 0.1} (east) and Σ{sub SFR} ∼ 10{sup 4.1} {sup ±} {sup 0.1}(west) M

  8. High-level nuclear-waste disposal: information exchange and conflict resolution

    International Nuclear Information System (INIS)

    Hadden, S.G.; Chiles, J.R.; Anaejionu, P.; Cerny, K.J.

    1981-07-01

    The research presented here was conceived as an exploration of the interactions among parties involved in the resolution of the high-level radioactive waste (HLW) disposal issue. Because of the major differences in the nature of the interactions between levels of government, on the one hand, and between government and the public, on the other hand, this study is divided into two primary areas - public participation and intergovernmental relations. These areas are further divided into theoretical and practical considerations. The format of the paper reflects the divisions explained above as well as the interaction of the various authors. Public participation is addressed from a theoretical perspective in Part 2. In Part 3 an essentially pragmatic approach is taken drawing on experiences from similar exercises. These two aspects of the study are presented in separate parts because the authors worked largely independently. Intergovernmental relations is treated in Part 4. The treatment is organized as two Sections of Part 4 to reflect the authors' close interaction which yielded a more integrated treatment of the theoretical and practical aspects of intergovernmental relations. Detailed recommendations and conclusions appear in the final subsections of Parts 2, 3, and 4. Part 5, Summary and Conclusions, does not reiterate the detailed conclusions and recommendations presented in previous parts but rather expresses some general perceptions with respect to the high-level waste disposal issue. A brief review of the Table of Contents will assist in visualizing the detailed format of this study and in identifying the portions of greatest relevance to specific questions. A detailed Subject Index and an Acronym Index have been included for the reader's convenience

  9. Targeting high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance analysis with high-resolution radical scavenging profiles - bioactive secondary metabolites from the endophytic fungus Penicillium namyslowskii

    DEFF Research Database (Denmark)

    Wubshet, Sileshi Gizachew; Nyberg, Nils; Tejesvi, Mysore V.

    2013-01-01

    The high-resolution radical scavenging profile of an extract of the endophytic fungus Penicillium namyslowskii was used to target analysis by high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance spectroscopy, i.e., HPLC...... NMR probe designed for 1.7-mm NMR tubes. To further explore the potential of the above HPLC-HRMS-SPE-NMR platform for analysis of endophytic extracts, six peaks displaying no radical scavenging activity were also analyzed. This allowed unambiguous identification of six metabolites, i...... and griseofulvin, directly from crude extract via HPLC-HRMS-SPE-NMR. Dechlorodehydrogriseofulvin was reported for the first time from nature....

  10. Nuclear microscopy of biological specimens

    International Nuclear Information System (INIS)

    Watt, F.; Grime, G.W.; Brook, A.J.; Gadd, G.M.; Perry, C.C.; Pearce, R.B.; Turnau, K.; Watkinson, S.C.

    1991-01-01

    Recent developments in technology have enabled the scanning proton microprobe to scan at submicron spatial resolution on a routine basis. The use of the powerful combination of techniques PIXE (proton induced X-ray emission), nuclear (or Rutherford) backscattering (RBS), and secondary electron detection operating at this resolution will open up new areas in many scientific disciplines. This paper describes some of the work carried out in the biological sciences over the last year, using the Oxford SPM facility. Collaborations with biological scientists have drawn attention to the wealth of information that can be derived when these techniques are applied to micro-organisms, cells and plant tissue. Briefly described here are investigations into the uptake of heavy metals by the alga Pandorina morum, the structure of the diatom Stephanopyxis turris, the presence of various types of crystal structures within the cells of Spirogyra, the heavy metal uptake of a mycorrhizal fungus present in the bracken (Pteridium aquilinum) root, the role of sphagnum moss in the absorption of inorganic elements, the measurement of heavy metals in environmentally-adapted cells of the yeast Saccharomyces cerevisiae, and the elemental distribution in the growing tip of a spore from the plant Equisetum arvense, with special emphasis placed on the visual interpretation of the elemental and secondary-electron maps provided by the nuclear microscopical techniques. (orig.)

  11. Deep PIXE: finding diamonds with the proton microprobe

    International Nuclear Information System (INIS)

    Griffin, W.L.; Ryan, C.G.

    1991-01-01

    Since 1987 the CSIRO Div. of Exploration Geoscience has carried out a program of proton-microprobe (PIXE) analysis aimed at using trace-element data on indicator minerals to discriminate between those from diamondiferous and barren source rocks. The results have provided both important new tools for the exploration industry, and significant new information on the conditions and processes of diamond growth. Cr-pyrope garnet has been used as Ni thermometer while chromites, in partcular their Zn content, has allowed correlation of chromite composition with temperature. The two techniques described provide a significant increase in exploration efficiency, through early recognition and rejection of barren targets and concentration of resources on more promising targets. They also provide direct cost savings in evaluation of ore bodies once they are found. It is estimated that evaluation of a prospect by conventional bulk testing is expensive ($100-500K) and time-consuming; an evaluation by PIXE methods is done quickly for a tiny fraction of that cost. 1 refs., 4 figs

  12. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    International Nuclear Information System (INIS)

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  13. Raman microprobe measurements of stress in ion implanted materials

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, K W; Prawer, S; Weiser, P S; Dooley, S P [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Raman microprobe measurements of ion implanted diamond and silicon have shown significant shifts in the Raman line due to stresses in the materials. The Raman line shifts to higher energy if the stress is compressive and to lower energy for tensile stress{sup 1}. The silicon sample was implanted in a 60 {mu}m square with 2.56 x 10{sup 17} ions per square centimeter of 2 MeV Helium. This led to the formation of raised squares with the top 370mm above the original surface. In Raman studies of silicon using visible light, the depth of penetration of the laser beam into the sample is much less than one micron. It was found that the Raman line is due to the silicon overlying the damage region. The diamond sample was implanted with 2 x 10{sup 15} ions per square centimeter of 2.8 MeV carbon. It was concluded that the Raman spectrum could provide information concerning both the magnitude and the direction of stress in an ion implanted sample. It was possible in some cases to determine whether the stress direction is parallel or perpendicular to the sample surface. 1 refs., 2 figs.

  14. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  15. Raman microprobe measurements of stress in ion implanted materials

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, K.W.; Prawer, S.; Weiser, P.S.; Dooley, S.P. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Raman microprobe measurements of ion implanted diamond and silicon have shown significant shifts in the Raman line due to stresses in the materials. The Raman line shifts to higher energy if the stress is compressive and to lower energy for tensile stress{sup 1}. The silicon sample was implanted in a 60 {mu}m square with 2.56 x 10{sup 17} ions per square centimeter of 2 MeV Helium. This led to the formation of raised squares with the top 370mm above the original surface. In Raman studies of silicon using visible light, the depth of penetration of the laser beam into the sample is much less than one micron. It was found that the Raman line is due to the silicon overlying the damage region. The diamond sample was implanted with 2 x 10{sup 15} ions per square centimeter of 2.8 MeV carbon. It was concluded that the Raman spectrum could provide information concerning both the magnitude and the direction of stress in an ion implanted sample. It was possible in some cases to determine whether the stress direction is parallel or perpendicular to the sample surface. 1 refs., 2 figs.

  16. Iron distribution in cancer cells following doxorubicin exposure using proton and X-ray synchrotron radiation microprobes

    International Nuclear Information System (INIS)

    Ortega, R.; Deves, G.; Bohic, S.; Simionovici, A.; Menez, B.; Bonnin-Mosbah, M.

    2001-01-01

    Chemical studies have shown that doxorubicin, a well-established anticancer agent, is a powerful iron chelator and the resultant iron-drug complex is an efficient catalyst of the conversion of hydrogen peroxide to the highly reactive hydroxyl radical. However, the intracellular complexation of doxorubicin with iron is still debated. Using nuclear microprobe analysis (NMPA), we previously observed in human ovarian cancer cells exposed to 20 μM iodo-doxorubicin (IDX) that iodine and iron cellular distributions were spatially correlated, suggesting a mechanism of intracellular iron chelation by the anthracycline compound. Because maximal plasma drug concentrations in patients are expected to be around 5 μM, NMPA and X-ray absorption near edge spectroscopy (XANES) experiments for iron speciation analysis were performed on cultured cells exposed to pharmacological doses of 2 μM IDX or doxorubicin

  17. Ultra High Spatial Resolution Ion Imaging with a NanoSIMS Ion Microprobe: Applications to Astrobiology

    OpenAIRE

    伊藤, 元雄; Ito, Motoo

    2013-01-01

    会議情報: 国際アストロバイオロジーワークショップ2013(第6回日本アストロバイオロジーネットワーク年次研究会)(2013年11月28日-30日. 宇宙航空研究開発機構宇宙科学研究所(JAXA)(ISAS)), 相模原市, 神奈川県

  18. Windowed direct exponential curve resolution quantification of nuclear magnetic resonance spectroscopy with applications to amniotic fluid metabonomics

    International Nuclear Information System (INIS)

    Botros, L.L.

    2007-01-01

    This thesis presents a quantitative protocol of proton nuclear magnetic resonance ( 1 H NMR) that allows the determination of human amniotic fluid metabolite concentrations, which are then used in a metabonomic study to establish patient health during gestation. 1 H NMR free inductive decays (FIDs) of 258 human amniotic fluid samples from a 500MHz spectrometer are acquired. Quantitative analyses methods in both the frequency- and time-domain are carried out and compared. Frequency-domain analysis is accomplished by integration of the metabolite peaks before and after the inclusion of a known standard addition of alanine. Time-domain analysis is accomplished by the direct exponential curve resolution algorithm (DECRA). Both techniques are assessed by applications to calibration biological solutions and a simulated data set. The DECRA method proves to be a more accurate and precise route for quantitative analysis, and is included in the developed protocol. Well-defined peaks of various components are visible in the frequency-domain 1 H NMR spectra, including lactate, alanine, acetate, citrate, choline, glycine, and glucose. All are quantified with the proposed protocol. Statistical t-test and notched box and whisker plots are used to compare means of metabolite concentrations for diabetic and normal patients. Glucose, glycine, and choline are all found to correlate with gestational diabetes mellitus early in gestation. With further development, time-domain quantitative 1 H NMR has potential to become a robust diagnostic tool for gestational health. (author)

  19. Windowed direct exponential curve resolution quantification of nuclear magnetic resonance spectroscopy with applications to amniotic fluid metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Botros, L.L

    2007-07-01

    This thesis presents a quantitative protocol of proton nuclear magnetic resonance ({sup 1}H NMR) that allows the determination of human amniotic fluid metabolite concentrations, which are then used in a metabonomic study to establish patient health during gestation. {sup 1}H NMR free inductive decays (FIDs) of 258 human amniotic fluid samples from a 500MHz spectrometer are acquired. Quantitative analyses methods in both the frequency- and time-domain are carried out and compared. Frequency-domain analysis is accomplished by integration of the metabolite peaks before and after the inclusion of a known standard addition of alanine. Time-domain analysis is accomplished by the direct exponential curve resolution algorithm (DECRA). Both techniques are assessed by applications to calibration biological solutions and a simulated data set. The DECRA method proves to be a more accurate and precise route for quantitative analysis, and is included in the developed protocol. Well-defined peaks of various components are visible in the frequency-domain {sup 1}H NMR spectra, including lactate, alanine, acetate, citrate, choline, glycine, and glucose. All are quantified with the proposed protocol. Statistical t-test and notched box and whisker plots are used to compare means of metabolite concentrations for diabetic and normal patients. Glucose, glycine, and choline are all found to correlate with gestational diabetes mellitus early in gestation. With further development, time-domain quantitative {sup 1}H NMR has potential to become a robust diagnostic tool for gestational health. (author)

  20. On the identification of carbonaceous aerosols via 14C accelerator mass spectrometry, and laser microprobe mass spectrometry

    International Nuclear Information System (INIS)

    Currie, L.A.; Fletcher, R.A.; Klouda, G.A.

    1987-01-01

    Carbon isotopic measurements ( 12 C, 14 C), derived from chemical measurements of total carbon plus AMS measurements of 14 C/ 12 C have become an accepted means for estimating fossil and contemporary carbon source contributions to atmospheric carbon. Because of the limited sensitivity of these techniques, however, such measurements are restricted to 'bulk' samples comprising at least 10-100 μg of carbon. Laser microprobe mass spectrometry (LMMS) offers an important complementary opportunity to investigate the chemical nature of individual particles as small as 0.1 μm in diameter. Although there is little hope to measure 14 C/ 12 C in such small samples, the compositional and structural information available with the laser microprobe is of interest for possible source discrimination. Also, the analysis of individual particles, which may reflect individual sources, yields significant potential increases in spatial, temporal and source resolution, in comparison to bulk sample analysis. Results of our exploratory investigation of known sources of carbonaceous particles, using LMMS, are presented. By applying multivariate techniques to laser mass spectra of soot from the combustion of heptane and wood, we found striking differences in the alkali metals (notably potassium) in the positive ion mass spectra. For ambient particles, 14 C has proved to be a crucial adjunct for the development and validation of the LMMS approach to single particle source assignment via carbon cluster pattern recognition. The combined techniques offer great promise for objective modeling (number and types of carbon sources) and for extension of the dichotomous carbon apportionment (fossil, contemporary) to subclasses such as soot from wood and agricultural burning, and that from coal and petroleum combustion. (orig.)

  1. Nuclear Physics Group progress report

    International Nuclear Information System (INIS)

    Coote, G.E.

    1985-02-01

    This report summarises the work of the Nuclear Physics Group of the Institute of Nuclear Sciences during the period January-December 1983. Commissioning of the EN-tandem electrostatic accelerator continued, with the first proton beam produced in June. Many improvements were made to the vacuum pumping and control systems. Applications of the nuclear microprobe on the 3MV accelerator continued at a good pace, with applications in archaeometry, dental research, studies of glass and metallurgy

  2. Super-resolution imaging visualizes the eightfold symmetry of gp210 proteins around the nuclear pore complex and resolves the central channel with nanometer resolution

    NARCIS (Netherlands)

    Löschberger, A.; Van de Linde, S.; Debauvalle, M.C.; Rieger, B.; Heilemann, M.; Krohne, G.; Sauer, M.

    2012-01-01

    One of the most complex molecular machines of cells is the nuclear pore complex (NPC), which controls all trafficking of molecules in and out of the nucleus. Because of their importance for cellular processes such as gene expression and cytoskeleton organization, the structure of NPCs has been

  3. Localization microscopy of DNA in situ using Vybrant{sup ®} DyeCycle™ Violet fluorescent probe: A new approach to study nuclear nanostructure at single molecule resolution

    Energy Technology Data Exchange (ETDEWEB)

    Żurek-Biesiada, Dominika [Laboratory of Cell Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Gronostajowa 7, 30-387 Kraków (Poland); Szczurek, Aleksander T. [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Prakash, Kirti [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Institute for Pharmacy and Molecular Biotechnology (IPMB), University of Heidelberg, Im Neuenheimer Feld 364, D-69120 Heidelberg (Germany); Mohana, Giriram K. [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Lee, Hyun-Keun [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Department of Physics, University of Mainz (JGU), Staudingerweg 7, 55128 Mainz (Germany); Roignant, Jean-Yves [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Birk, Udo J. [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Department of Physics, University of Mainz (JGU), Staudingerweg 7, 55128 Mainz (Germany); Dobrucki, Jurek W., E-mail: jerzy.dobrucki@uj.edu.pl [Laboratory of Cell Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Gronostajowa 7, 30-387 Kraków (Poland); Cremer, Christoph, E-mail: c.cremer@imb-mainz.de [Institute of Molecular Biology (IMB), Ackermannweg 4, 55128 Mainz (Germany); Institute for Pharmacy and Molecular Biotechnology (IPMB), University of Heidelberg, Im Neuenheimer Feld 364, D-69120 Heidelberg (Germany); Department of Physics, University of Mainz (JGU), Staudingerweg 7, 55128 Mainz (Germany)

    2016-05-01

    Higher order chromatin structure is not only required to compact and spatially arrange long chromatids within a nucleus, but have also important functional roles, including control of gene expression and DNA processing. However, studies of chromatin nanostructures cannot be performed using conventional widefield and confocal microscopy because of the limited optical resolution. Various methods of superresolution microscopy have been described to overcome this difficulty, like structured illumination and single molecule localization microscopy. We report here that the standard DNA dye Vybrant{sup ®} DyeCycle™ Violet can be used to provide single molecule localization microscopy (SMLM) images of DNA in nuclei of fixed mammalian cells. This SMLM method enabled optical isolation and localization of large numbers of DNA-bound molecules, usually in excess of 10{sup 6} signals in one cell nucleus. The technique yielded high-quality images of nuclear DNA density, revealing subdiffraction chromatin structures of the size in the order of 100 nm; the interchromatin compartment was visualized at unprecedented optical resolution. The approach offers several advantages over previously described high resolution DNA imaging methods, including high specificity, an ability to record images using a single wavelength excitation, and a higher density of single molecule signals than reported in previous SMLM studies. The method is compatible with DNA/multicolor SMLM imaging which employs simple staining methods suited also for conventional optical microscopy. - Highlights: • Super-resolution imaging of nuclear DNA with Vybrant Violet and blue excitation. • 90nm resolution images of DNA structures in optically thick eukaryotic nuclei. • Enhanced resolution confirms the existence of DNA-free regions inside the nucleus. • Optimized imaging conditions enable multicolor super-resolution imaging.

  4. Quantification of hydrogen distribution with the nuclear microprobe of the Pierre Sue Laboratory in the thickness of the PWR fuel cladding in zirconium alloy; Quantification de la repartition de l'hydrogene a la microsonde nucleaire du Laboratoire Pierre Sue dans l'epaisseur du tube de gainage du combustible des REP en alliage de zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Raepsaet, C. [Laboratoire Pierre Sue (DSM/DRECAM/LPS) - CEA Saclay, 91 - Gif-sur-Yvette (France); Bossis, Ph. [CEA Saclay, Dept. des Materiaux pour le Nucleaire (DEN/DANS/DMN/SEMI/LM2E), 91 - Gif sur Yvette (France); Hamon, D.; Bechade, J.L.; Brachet, J.C. [CEA Saclay, Dept. des Materiaux pour le Nucleaire (DEN/DANS/DMN/SRMA/LA2M), 91 - Gif sur Yvette (France)

    2007-07-01

    In a first part of this study, are detailed the general principles of the specific technique ERDA (Elastic Recoil Detection Analysis) used in the Pierre Sue Laboratory. Then, the contribution of this technique is illustrated with two studies examples on the behaviour of PWR nuclear fuel cladding. (O.M.)

  5. Resolution s/n it approves the proposal by the National Directorate of Energy and Nuclear Technology in the terms set out in the working groups mentioned

    International Nuclear Information System (INIS)

    2006-01-01

    The following Resolution has been stated because of the results of the workshops Elaboration of proposals for strategic guidelines held from 2 to May 5, 2006, elaboration of proposals for the Strategic Lines instruments held from 24 to July 28, 2006, as well as documents Proposal of politic energetic Uruguayan Energy Sector development and proposal of Energy Policy Instruments developed by the National Directorate of Nuclear Energy and Technology and the Energy Strategy Guidelines Uruguay 2006.

  6. High resolution γ spectra of 40-44 MeV γ photon activation products: Part 3 - a summary of γ rays, radionuclides and nuclear interferences observed

    International Nuclear Information System (INIS)

    Williams, D.R.; Hislop, J.S.

    1980-09-01

    A table of γ rays observed in the high resolution γ ray spectra of 40 to 44 MeV γ photon activation products is presented. This table is arranged in order of increasing γ ray energy and the parent isotopes, their half-lives and their inactive precursors are identified. Nuclear interferences caused by production of an active isotope from different parent elements have been identified and evaluated quantitatively. These are also tabulated. (author)

  7. Detection of tannins in modern and fossil barks and in plant residues by high-resolution solid-state /sup 13/C nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M A; Hatcher, P G

    1988-01-01

    Bark samples isolated from brown coal deposits in Victoria, Australia, and buried wood from Rhizophora mangle have been studied by high-resolution solid-state nuclear magnetic resonance (NMR) techniques. Dipolar dephasing /sup 13/C NMR appears to be a useful method of detecting the presence of tannins in geochemical samples including barks, buried woods, peats and leaf litter. It is shown that tannins are selectively preserved in bark during coalification to the brown coal stage. 28 refs., 9 figs., 1 tab.

  8. Detection of tannins in modern and fossil barks and in plant residues by high-resolution solid-state 13C nuclear magnetic resonance

    Science.gov (United States)

    Wilson, M.A.; Hatcher, P.G.

    1988-01-01

    Bark samples isolated from brown coal deposits in Victoria, Australia, and buried wood from Rhizophora mangle have been studies by high-resolution solid-state nuclear magnetic resonance (NMR) techniques. Dipolar dephasing 13C NMR appears to be a useful method of detecting the presence of tannins in geochemical samples including barks, buried woods, peats and leaf litter. It is shown that tannins are selectively preserved in bark during coalification to the brown coal stage. ?? 1988.

  9. Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

    Science.gov (United States)

    Fournelle, John; Carpenter, Paul

    2006-01-01

    Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

  10. An x-ray microprobe using focussing optics with a synchrotron radiation source

    International Nuclear Information System (INIS)

    Thompson, A.C.; Underwood, J.H.; Wu, Y.; Giauque, R.D.

    1989-01-01

    An x-ray microprobe can be used to produce maps of the concentration of elements in a sample. Synchrotron radiation provides x-ray beams with enough intensity and collimation to make possible elemental images with femtogram sensitivity. The use of focussing x-ray mirrors made from synthetic multilayers with a synchrotron x-ray beam allows beam spot sizes of less than 10 μm /times/ 10 μm to be produced. Since minimal sample preparation is required and a vacuum environment is not necessary, there will be a wide variety of applications for such microprobes. 8 refs., 6 figs

  11. The PNC/XOR x-ray microprobe station at APS sector 20

    International Nuclear Information System (INIS)

    Heald, S. M.; Cross, J. O.; Brewe, D. L.; Gordon, R. A.

    2007-01-01

    The X-ray microprobe is the most popular experimental setup at the PNC/XOR insertion device beamline located at sector 20 at the Advanced Photon Source. To satisfy user demand and to simplify the setup, we have developed a dedicated station with multiple detection options. This paper will describe the setup in detail and demonstrate the capabilities with some example imaging, micro-XAS and microdiffraction data. In the future, an improved version of the microprobe will be installed on a dedicated undulator. The improvements planned for this station are based on our operational experience and will also be discussed

  12. Polymer SU-8 Based Microprobes for Neural Recording and Drug Delivery

    Science.gov (United States)

    Altuna, Ane; Fernandez, Luis; Berganzo, Javier

    2015-06-01

    This manuscript makes a reflection about SU-8 based microprobes for neural activity recording and drug delivery. By taking advantage of improvements in microfabrication technologies and using polymer SU-8 as the only structural material, we developed several microprobe prototypes aimed to: a) minimize injury in neural tissue, b) obtain high-quality electrical signals and c) deliver drugs at a micrometer precision scale. Dedicated packaging tools have been developed in parallel to fulfill requirements concerning electric and fluidic connections, size and handling. After these advances have been experimentally proven in brain using in vivo preparation, the technological concepts developed during consecutive prototypes are discussed in depth now.

  13. POLYMER SU-8 BASED MICROPROBES FOR NEURAL RECORDING AND DRUG DELIVERY

    Directory of Open Access Journals (Sweden)

    Ane eAltuna

    2015-06-01

    Full Text Available This manuscript makes a reflection about SU-8 based microprobes for neural activity recording and drug delivery. By taking advantage of improvements in microfabrication technologies and using polymer SU-8 as the only structural material, we developed several microprobe prototypes aimed to: a minimize injury in neural tissue, b obtain high-quality electrical signals and c deliver drugs at a micrometer precision scale. Dedicated packaging tools have been developed in parallel to fulfill requirements concerning electric and fluidic connections, size and handling. After these advances have been experimentally proven in brain using in vivo preparation, the technological concepts developed during consecutive prototypes are discussed in depth now.

  14. The new Schonland PIXE microprobe and applications to geological and archaeological samples

    Energy Technology Data Exchange (ETDEWEB)

    Przybylowicz, W J; Watterson, J I.W.; Annegarn, H J; Connell, S H; Fearick, R W; Andeweg, A H; Sellschop, J P.F. [Schonland Research Centre for Nuclear Sciences, Univ. of the Witwatersrand, Johannesburg (South Africa)

    1993-04-01

    The new positive ion microprobe at the Schonland Centre is described and details are given of its configuration, its imaging system and software. In a unique configuration, the microprobe has access to two accelerators, a 6 MV EN tandem and a 2.5 MV single-ended machine. The imaging system uses a CAMAC based system and runs on a personal computer under OS/2. The implementation of PIXE and treatment of thick-target data are presented. Applications discussed are analysis of tin artifacts from the prehistory of metallurgy in South Africa; a diamond-containing rock; carbonado, gold contained in pyrite and cogenetic minerals included in diamond. (orig.).

  15. The new Schonland PIXE microprobe and applications to geological and archaeological samples

    International Nuclear Information System (INIS)

    Przybylowicz, W.J.; Watterson, J.I.W.; Annegarn, H.J.; Connell, S.H.; Fearick, R.W.; Andeweg, A.H.; Sellschop, J.P.F.

    1993-01-01

    The new positive ion microprobe at the Schonland Centre is described and details are given of its configuration, its imaging system and software. In a unique configuration, the microprobe has access to two accelerators, a 6 MV EN tandem and a 2.5 MV single-ended machine. The imaging system uses a CAMAC based system and runs on a personal computer under OS/2. The implementation of PIXE and treatment of thick-target data are presented. Applications discussed are analysis of tin artifacts from the prehistory of metallurgy in South Africa; a diamond-containing rock; carbonado, gold contained in pyrite and cogenetic minerals included in diamond. (orig.)

  16. Theory of equidistant three-dimensional radiance measurements with optical microprobes RID A-1977-2009

    DEFF Research Database (Denmark)

    FukshanskyKazarinova, N.; Fukshansky, L.; Kuhl, Morten

    1996-01-01

    Fiber-optic radiance microprobes, increasingly applied for measurements of internal light fields in living tissues, provide three-dimensional radiance distribution solids and radiant energy fluence rates at different depths of turbid samples. These data are, however, distorted because of an inher...... of application is presented. The limitations of this theory and the prospects for this approach are discussed....... of an inherent feature of optical fibers: nonuniform angular sensitivity. Because of this property a radiance microprobe during a single measurement partly underestimates light from the envisaged direction and partly senses light from other directions. A theory of three-dimensional equidistant radiance...

  17. Nuclear Physics Group progress report January - December 1982

    International Nuclear Information System (INIS)

    Coote, G.E.

    1983-08-01

    The work of the Nuclear Physics Group of the Institute of Nuclear Sciences during the period July-December 1981 is described. Installation of the EN-tandem electrostatic accelerator proceeded to the voltage test stage. Highlights of the research programme included nuclear microprobe studies of bone and teeth, and depth profiling of sodium in hydrated obsidian

  18. A method for improving the efficiency of proton microprobe profiling of strontium in otoliths using a vacuum compatible NaI detector

    International Nuclear Information System (INIS)

    Barry, B.; Markwitz, A.

    2004-01-01

    The precision of proton microprobe measurements of Sr in otoliths by proton induced X-ray emission (PIXE) has been improved significantly by use of a large area low resolution NaI(Tl) detector. This is achieved by scanning the sample simultaneously with a high resolution Si(Li) detector to measure the main constituent Ca and to confirm the absence of other elements in the counting window used by the large area detector. In our experimental setup the count rate for Sr was improved by a factor of 30. We took advantage of this to improve precision and achieve higher sample throughput in studies of diadromous fish, i.e. those whose life cycles may include both marine and freshwater stages

  19. Data acquisition and analysis system for the ion microprobe mass analyzer

    International Nuclear Information System (INIS)

    Darby, D.M.; Cristy, S.S.

    1979-02-01

    A computer was interfaced to an ion microprobe mass analyzer for more rapid data acquisition and analysis. The interface is designed to allow data acquisition, independent of the computer. A large data analysis package was developed and implemented. Performance of the computerized system was evaluated and compared to manual operation

  20. Characterization of Alq3 thin films by a near-field microwave microprobe.

    Science.gov (United States)

    Hovsepyan, Artur; Lee, Huneung; Sargsyan, Tigran; Melikyan, Harutyun; Yoon, Youngwoon; Babajanyan, Arsen; Friedman, Barry; Lee, Kiejin

    2008-09-01

    We observed tris-8-hydroxyquinoline aluminum (Alq3) thin films dependence on substrate heating temperatures by using a near-field microwave microprobe (NFMM) and by optical absorption at wavelengths between 200 and 900 nm. The changes of absorption intensity at different substrate heating temperatures are correlated to the changes in the sheet resistance of Alq3 thin films.

  1. Microprobe investigation of brittle segregates in aluminum MIG and TIG welds

    Science.gov (United States)

    Larssen, P. A.; Miller, E. L.

    1968-01-01

    Quantitative microprobe analysis of segregated particles in aluminum MIG /Metal Inert Gas/ and TIG /Tungsten Inert Gas/ welds indicated that there were about ten different kinds of particles, corresponding to ten different intermetallic compounds. Differences between MIG and TIG welds related to the individual cooling rates of these welds.

  2. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J S; Bardos, R A; Saint, A; Moloney, G M; Legge, G F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1994-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  3. Evaluation of an x-ray microprobe technique as a possible aid to detect salmonellae

    International Nuclear Information System (INIS)

    Richter, E.R.; Banwart, G.J.

    1982-01-01

    Specific bacterial antigen (Salmonella) increased in phosphorus and sqlfur after reaction with the flukrescain isothiocyanate-tagged anti-Salmonella antibody, while nonspecific antigen (Escherichia coli) did not. X-ray microprobe analysis may be useful in detecting salmonellae or other bacteria by determining increases in the elemental constituents of bacterial cells when reacted with elemental-tagged antibodies

  4. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, S. [Tokyo Univ. (Japan). Faculty of Medicine; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-12-31

    To investigate the cause of Alzheimer`s disease (senile dementia of Alzheimer`s disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer`s disease using heavy ion (5 MeV Si{sup 3+}) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si{sup 2+}) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer`s disease using 5 MeV Si{sup 3+} microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer`s disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  5. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J.S.; Bardos, R.A.; Saint, A.; Moloney, G.M.; Legge, G.F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1993-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  6. Elemental microanalysis of biological and medical specimens with a scanning proton microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; Mazzolini, A.P.

    1979-01-01

    The scanning proton microprobe is shown to be a sensitive instrument for elemental microanalysis of cells and tissues in biological and medical specimens. The preparation of specimens and their behaviour under irradiation are crucial and the application of quantitative scanning analysis to the monitoring of such problems is illustrated

  7. High-resolution nuclear magnetic resonance of quadrupolar nuclei in solids; Resonance magnetique nucleaire haute-resolution des noyaux quadrupolaires dans les solides

    Energy Technology Data Exchange (ETDEWEB)

    Charpentier, Th

    1998-10-23

    After a brief review of existing methods in high-resolution NMR of quadrupolar nuclei, the manipulation of multi-quantum coherencies by radiofrequency pulses is studied. Results are then applied to the determination of optimal conditions for performing the recently introduced multiple-quantum magic-angle experiment (MQMAS). The principles of this new method, the different pulse sequences and the data processing are described in detail. Applications on aluminum hydrates and cement pastes show the improvements of this new technique over the previous ones. In a second part, after an investigation of the Floquet theory, a new formalism has been devised for studying the behavior of a spin submitted to a strong quadrupolar interaction and radiofrequency field in a rotating sample. This formalism is then applied to a quantitative study of the phenomenon of rotational induced adiabatic transfer of coherencies (RIACT). The extension of our theoretical approach to two-dimensional experiments provides a powerful tool for quantitative analyses of MQMAS spectra. Agreement between experimental data and simulations demonstrates the reliability of our approach. Preliminary results concerning the application of MQMAS spectroscopy, using our simulation programs, to structural study of amorphous materials are presented. The third and last part presents a theoretical and experimental investigation of dipolar order in a rotating sample. Two theoretical models are described, the first for the slow spinning speed regime where an adiabatic approximation can be made, and the second for the fast spinning speed regime. (author)

  8. Spectral Light Measurements in Microbenthic Phototrophic Communities with a Fiberoptic Microprobe Coupled to a Sensitive Diode-Array Detector Rid A-1977-2009

    DEFF Research Database (Denmark)

    KUHL, M.; JØRGENSEN, BB

    1992-01-01

    with microelectrode measurements of oxygenic photosynthesis in the coastal sediment. With an incident light intensity of 200 muEinst m-2 s-1, photon scalar irradiance reached a maximum of 283 muEinst m-2 s-1 at the sediment surface. The lower boundary of the euphotic zone was 2.2 mm below the surface at a light......A diode array detector system for microscale light measurements with fiber-optic microprobes was developed; it measures intensities of 400-900-nm light over >6 orders of magnitude with a spectral resolution of 2-5 nm. Fiber-optic microprobes to measure field radiance or scalar irradiance were...... extinction maxima in measured radiance spectra at 430-550 nm (Chl a and carotenoids), 620-625 nm (phycocyanin), 675 nm (Chl a), 745-750 nm (BChl c), 800-810 nm, and 860-880 nm (BChl a). Scalar irradiance spectra exhibited a different spectral composition and a higher light intensity at the sediment surface...

  9. Complementary microanalysis of Zn, Mn and Fe in the chelicera of spiders and scorpions using scanning MeV-ion and electron microprobes

    International Nuclear Information System (INIS)

    Schofield, R.; Lefevre, H.; Shaffer, M.

    1989-01-01

    Energy-loss scanning transmission ion microscopy (ELSTIM or just STIM), PIXE and electron microprobe techniques are used to investigate certain minor element accumulations in a few spiders and scorpions. STIM and PIXE are used to survey the unsectioned specimens, while electron microprobe techniques are used for higher resolution investigations of several sections of the specimens. Concentration values measured using STIM and PIXE are found to be in satisfactory agreement with those measured using electron probe microanalysis. A garden spider Araneous diadematus is found to contain high concentrations of zinc in a thin layer near the surface of its fangs (reaching 23% of dry weight), and manganese in its marginal teeth (about 5% of dry weight). A wolf spider Alopecosa kochi is found to have similar concentrations of zinc in a layer near the surface of it's fang, and concentrations of manganese reaching 1.5% in a layer beneath the zinc containing layer. A scorpion Centruroides sp. is found to contain high concentrations of iron (reaching 8%) and zinc (reaching 24%) in the tips of teeth on the cheliceral fingers, and manganese (about 5%) in the stinger. The hypothesis that these elements simply harden the cuticle does not appear to explain their segregation patterns. (orig.)

  10. S. Con. Res. 148: concurrent resolution expressing the sense of congress concerning the nuclear disaster at Chernobyl in the Soviet Union. Introduced in the Senate of the United States, Ninety-Ninth Congress, Second Session, June 13, 1986

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The resolution expresses Congressional concern over the nuclear disaster at Chernobyl, particularly in the area of loss of food and livestock in the area affected by the accident. Noting the US tradition and capacity to provide food assistance, the resolution calls upon the Agriculture Secretary to promote and assist the commercial sale of live dairy cows and dairy beef products to foreign countries

  11. Super-resolution imaging of a 2.5 kb non-repetitive DNA in situ in the nuclear genome using molecular beacon probes

    Science.gov (United States)

    Ni, Yanxiang; Cao, Bo; Ma, Tszshan; Niu, Gang; Huo, Yingdong; Huang, Jiandong; Chen, Danni; Liu, Yi; Yu, Bin; Zhang, Michael Q; Niu, Hanben

    2017-01-01

    High-resolution visualization of short non-repetitive DNA in situ in the nuclear genome is essential for studying looping interactions and chromatin organization in single cells. Recent advances in fluorescence in situ hybridization (FISH) using Oligopaint probes have enabled super-resolution imaging of genomic domains with a resolution limit of 4.9 kb. To target shorter elements, we developed a simple FISH method that uses molecular beacon (MB) probes to facilitate the probe-target binding, while minimizing non-specific fluorescence. We used three-dimensional stochastic optical reconstruction microscopy (3D-STORM) with optimized imaging conditions to efficiently distinguish sparsely distributed Alexa-647 from background cellular autofluorescence. Utilizing 3D-STORM and only 29–34 individual MB probes, we observed 3D fine-scale nanostructures of 2.5 kb integrated or endogenous unique DNA in situ in human or mouse genome, respectively. We demonstrated our MB-based FISH method was capable of visualizing the so far shortest non-repetitive genomic sequence in 3D at super-resolution. DOI: http://dx.doi.org/10.7554/eLife.21660.001 PMID:28485713

  12. Resolution proposition for the creation of an inquiry commission on dysfunctions of the nuclear sector in France

    International Nuclear Information System (INIS)

    2009-11-01

    Written by members of the French Parliament, this paper comments different dysfunctions of the French nuclear sector which could justify the creation of an official parliamentary inquiry commission. These dysfunctions concern uncertainties in the EPR system, the discovery of a quantity of enriched uranium greater than the authorized one in Cadarache, the export of nuclear wastes in Siberia, the general safety of French nuclear power stations, the right to information, the financial problems met by the sector in relationship with a recent loan and foreign investments, the relationship between the African origin of uranium supplies and human rights in these countries, the practices of espionage of NGOs and anti-nuclear associations by EDF

  13. Photovoltage versus microprobe sheet resistance measurements on ultrashallow structures

    DEFF Research Database (Denmark)

    Clarysse, T.; Moussa, A.; Parmentier, B.

    2010-01-01

    on ultrashallow (sub-50-nm) chemical-vapor-deposited layers [T. Clarysse , Mater. Res. Soc. Symp. Proc. 912, 197 (2006)], especially in the presence of medium/highly doped underlying layers (representative for well/halo implants). Here the authors examine more closely the sheet resistance anomalies which have...... recently been observed between junction photovoltage (JPV) based tools and a micrometer-resolution four-point probe (M4PP) tool on a variety of difficult, state-of-the-art sub-32-nm complementary metal-oxide semiconductor structures (low energy and cluster implants, with/without halo, flash- and laser...

  14. High-resolution 13C nuclear magnetic resonance evidence of phase transition of Rb,Cs-intercalated single-walled nanotubes

    KAUST Repository

    Bouhrara, M.

    2011-09-06

    We present 13 C high-resolution magic-angle-turning (MAT) and magic angle spinning nuclear magnetic resonance data of Cs and Rb intercalated single walled carbon nanotubes. We find two distinct phases at different intercalation levels. A simple charge transfer is applicable at low intercalation level. The new phase at high intercalation level is accompanied by a hybridization of alkali (s) orbitals with the carbon (sp2) orbitals of the single walled nanotubes, which indicate bundle surface sites is the most probable alkali site.

  15. Nuclear structure studies using the high resolution spectrometer at the Los Alamos Clinton P. Anderson Meson Physics Facility: Progress report, [1986-1987

    International Nuclear Information System (INIS)

    Hoffmann, G.W.

    1986-12-01

    A major part of the work done this past year was associated with research conducted at the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF) using the High Resolution Spectrometer (HRS) and the External Proton Beam (EPB). The research focussed on (1) providing p + nucleus data which test nonrelativistic and relativistic models of the medium energy proton + nucleus interaction, (2) providing (p,p) and (p,n) data which are to be analyzed to provide new nuclear structure information (both ground state and excited state), (3) providing nucleon + nucleon data to aid in the systematic study of the fundamental nucleon-nucleon interaction, (4) developing and improving the pA models themselves, and (5) initiating new experimental programs whose goals are to search for new phenomena in nuclear physics

  16. S.RES. 455: resolution to call for the creation of an early notification system for nuclear accidents. Introduced in the Senate of the United States, Ninety-Congress, Second Session, July 28, 1986

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The resolution calls for the creation of an early notification system for nuclear accidents. It is a response to the Chernobyl nuclear power station accident in the Soviet Union, and reflects international concern over the time that passed before warnings and information were made public

  17. Using x-ray microprobes for environmental research

    International Nuclear Information System (INIS)

    Cai, Z.; Jastrow, J.; Kemner, K. M.; Lai, B.; Lee, H.-R.; Legnini, D. G.; Miller, R. M.; Pratt, S. T.; Rodrigues, W.; Yun, W.

    1998-01-01

    Understanding the fate of environmental contaminants is of fundamental importance in the development and evaluation of effective remediation strategies. Among the factors influencing the transport of these contaminants are the chemical speciation of the sample and the chemical and physical attributes of the surrounding medium. Characterization of the spatial distribution and chemical speciation at micron and submicron resolution is essential for studying the microscopic physical, geological, chemical, and biological interfaces that play a crucial role in determining contaminant fate and mobility. Hard X-ray spectroscopy and imaging are powerful techniques for the element-specific investigation of complex environmental samples at the needed micron and submicron resolution. An important advantage of these techniques results from the large penetration depth of hard X-rays in water. This minimizes the requirements for sample preparation and allows the detailed study of hydrated samples. This paper discusses some current problems in environmental science that can be addressed by using synchrotron-based X-ray imaging and spectroscopy. These concepts are illustrated by the results of recent X-ray microscopy studies at the Advanced Photon Source

  18. Detection of delta-ferrite to sigma transformation using metallographic techniques involving ferromagnetic colloid, color etching, and microprobe analysis

    International Nuclear Information System (INIS)

    Gray, R.J.; Sikka, V.K.; King, R.T.

    1976-01-01

    The mechanical properties of ferrite-containing austenitic stainless steel base metal and weldments are usually adversely affected by prolonged exposure to temperatures in the 482 to 900 0 C (900 to 1652 0 F) range. One cause of the property alteration is related to the transformation of relatively ductile delta-ferrite to less ductile sigma-phase. Attempts to identify sigma and delta-ferrite phases by color staining techniques alone are well documented; however, the results are often questionable due to the difficulty in maintaining consistent color identifications. This investigation is concerned with the microstructural responses of the ferromagnetic delta-ferrite phase and the paramagnetic sigma-phase to a ferromagnetic iron colloid in a magnetic field. Such positive or negative responses of the two phases to the colloid offer a more definitive identification. With this technique, the identification of small amounts of these phases in the microstructure is limited only by the highest magnification and resolution of the optical microscope. The procedure is substantiated in this metallographic study with microprobe analysis and color metallography. Several examples of the correlative use of these three techniques in identifying varying amounts of delta-ferrite → sigma transformation are presented

  19. False colour backscatter electron images and their application during electron microprobe analysis of ores and host rocks

    International Nuclear Information System (INIS)

    Cousens, D.R.; French, D.H.; Ramsden, A.R.

    1989-01-01

    The limited contrast range of conventional black and white imaging does not enable full use to be made of the dynamic range of the video signal obtained from a scanning electron microscope or microprobe. The use of false colour substantially increases the information that can be derived from such images enabling relationships to be displayed that cannot be observed in black and white. This capability is now used extensively in combination with quantitative electron microprobe analysis as a research tool for ore characterization and host rocks studies related to minerals exploration in the CSIRO Div.sion of Exploration Geoscience. Thus the CAMEBAX scanning electron microprobe has been modified to allow digital images acquisition and software (IMAGE) developed which allows false colour backscatter electron (BSE) images to be obtained during the course of routine electron microprobe analysis. 1 fig

  20. General problems arising from the analogical resolution of the kinetic equations of nuclear reactors (1961); Problemes generaux poses par la resolution analogique des equations cinetiques des reacteurs nucleaires (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Caillet, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The author reviews precisely the analogical techniques used for the resolution of the kinetic equations of nuclear reactors. Prior to this, he recalls the reasons which oblige physicians and engineers, even today, to use electronic machines in this domain. The author then considers the technological problems posed by the range of values which the various nuclear parameters adopt. In each case, he shows that a compromise is possible allowing an optimum precision. He compares the results to those obtained by arithmetic calculation and uses the examples chosen in a critical analysis of the present possibilities of the two methods of calculation. (author) [French] L'auteur cherche a faire un point aussi exact que possible des techniques analogiques utilisees pour resoudre les equations cinetiques des reacteurs nucleaires. Il rappelle auparavant les raisons pour lesquelles physiciens et ingenieurs sont obliges, encore aujourd'hui, de faire appel aux machines electroniques dans ce domaine. Puis il etudie les problemes technologiques que souleve le champ des valeurs prises par les differents parametres nucleaires. Dans chacun des cas, il montre l'existence d'un compromis qui permet d'atteindre une precision optimum. Il compare les resultats obtenus a ceux provenant de calculateurs arithmetiques et profite des exemples choisis pour faire une analyse critique des possibilites actuelles offertes par les deux modes de calcul. (auteur)

  1. Charge collection control using retrograde well tested by proton microprobe irradiation

    International Nuclear Information System (INIS)

    Sayama, Hirokazu; Takai, Mikio; Kimura, Hiroshi; Ohno, Yoshikazu; Satoh, Shinichi; Sonoda, Kenichirou; Katani, Norihiko.

    1993-01-01

    Soft error reduction by high-energy ion-implanted layers has been investigated by novel evaluation techniques using high-energy proton microprobes. A retrograde well formed by 160 and 700 keV boron ion implantation could completely suppress soft errors induced by the proton microprobes at 400 keV. The proton-induced current revealed the charge collection efficiency for the retrograde well structure. The collected charge for the retrograde well in the soft-error mapping was proved to be lower than the critical charge of the measured DRAMs(dynamic random-access memories). Complementary use of soft-error mapping and ion-induced-current measurement could clarify well structures immune against soft errors. (author)

  2. Characterisation of corrosion processes of using electron micro-probe, scanning probe microscopy and synchrotron-generated x-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Neufeld, A.K.; Cole, I.S.; Furman, S.A.; Isaacs, H.S.

    2002-01-01

    Full text: With recent advances in computerized technology, the study of chemical reactions can now be visualized as they occur in real time and has resulted in analytical techniques with orders of magnitude greater sensitivity and resolution. This ability offers the corrosion scientist a unique opportunity to study the processes relevant to degradation science which could only be theoretically considered. Neufeld el al (1,2) have attempted to explain in great detail the mechanism of corrosion initiation of zinc by using X-ray micro-probe, Scanning Kelvin probe, and more recently by using synchrotron-generated X-rays and X-ray fluorescence imaging. New results are presented from the synchrotron studies where the transport of ions in-situ has been investigated. The synthesis of information from the techniques will also be discussed in its relevance to atmospheric corrosion processes. Copyright (2002) Australian Society for Electron Microscopy Inc

  3. Application of synchrotron-radiation-based x-ray microprobe techniques for the analysis of recombination activity of metals precipitated at Si/SiGe misfit dislocations

    CERN Document Server

    Vyvenko, O F; Istratov, A A; Weber, E R; Kittler, M; Seifert, W

    2002-01-01

    In this study we report application of synchrotron-radiation-based x-ray microprobe techniques (the x-ray-beam-induced current (XBIC) and x-ray fluorescence (mu-XRF) methods) to the analysis of the recombination activity and space distribution of copper and iron in the vicinity of dislocations in silicon/silicon-germanium structures. A combination of these two techniques enables one to study the chemical nature of the defects and impurities and their recombination activity in situ and to map metal clusters with a micron-scale resolution. XRF analysis revealed that copper formed clearly distinguishable precipitates along the misfit dislocations. A proportional dependence between the XBIC contrast and the number of copper atoms in the precipitates was established. In hydrogen-passivated iron-contaminated samples we observed clusters of iron precipitates which had no recombination activity detectable by the XBIC technique as well as iron clusters which were not completely passivated.

  4. Expert system applied at the Angra-2 Nuclear Power Plant to assist in the resolution of limiting conditions for operation

    International Nuclear Information System (INIS)

    Schechter, André D.; Nicolau, Andressa S.; Schirru, Roberto

    2017-01-01

    Expert Systems (ES) are widely used to help a common user act as an expert on a particular subject, the information is saved in the program database and the user introduces facts to be interpreted in real time. The inference engine will take these facts and return the answer of the expert. This tool is widely used, for example, in medicine to diagnose patients, game development, the mining industry, and the operation of nuclear power plants. In this article, a model of ES, of the real time, is development in order to treat the Limiting Conditions for Operation (LCO) of the Angra-2 Nuclear Power Plant. In this PWR plant, all information from the LCO comes from failure trees and the ES was adapted to be able to handle the facts with the values True, False, None and Null of the tree. The simulations results of this article and experiments with ES applied in LCOs show that it is an efficient computational tool to deal with this type of problem. The use of this type of technology in the operation of nuclear power plants can reduce the risk of an accident caused by human error, which is one of the most common causes in the history of the nuclear industry. (author)

  5. Expert system applied at the Angra-2 Nuclear Power Plant to assist in the resolution of limiting conditions for operation

    Energy Technology Data Exchange (ETDEWEB)

    Schechter, André D.; Nicolau, Andressa S.; Schirru, Roberto, E-mail: schechterandre@poli.ufrj.br, E-mail: andressa@lmp.ufrj.br, E-mail: schirru@lmp.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    Expert Systems (ES) are widely used to help a common user act as an expert on a particular subject, the information is saved in the program database and the user introduces facts to be interpreted in real time. The inference engine will take these facts and return the answer of the expert. This tool is widely used, for example, in medicine to diagnose patients, game development, the mining industry, and the operation of nuclear power plants. In this article, a model of ES, of the real time, is development in order to treat the Limiting Conditions for Operation (LCO) of the Angra-2 Nuclear Power Plant. In this PWR plant, all information from the LCO comes from failure trees and the ES was adapted to be able to handle the facts with the values True, False, None and Null of the tree. The simulations results of this article and experiments with ES applied in LCOs show that it is an efficient computational tool to deal with this type of problem. The use of this type of technology in the operation of nuclear power plants can reduce the risk of an accident caused by human error, which is one of the most common causes in the history of the nuclear industry. (author)

  6. A complete plastid phylogeny of Daucus – concordance to nuclear results, and markers necessary for phylogenetic resolution

    Science.gov (United States)

    Premise of study: Our purposes were to (1) obtain a well-resolved plastid counterpart to the 94 gene nuclear ortholog gene phylogeny of Arbizu et al. (2014, Amer. J. Bot. 101:1666-1685; and Syst. Bot., in press), and (2) to investigate various classes and numbers of plastid markers necessary for a c...

  7. Nuclear analysis techniques and environmental sciences

    International Nuclear Information System (INIS)

    1997-10-01

    31 theses are collected in this book. It introduced molecular activation analysis micro-PIXE and micro-probe analysis, x-ray fluorescence analysis and accelerator mass spectrometry. The applications about these nuclear analysis techniques are presented and reviewed for environmental sciences

  8. Study of ion tracks by micro-probe ion energy loss spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Vacík, Jiří; Havránek, Vladimír; Hnatowicz, Vladimír; Horák, Pavel; Fink, Dietmar; Apel, P. Yu.

    2014-01-01

    Roč. 332, AUG (2014), s. 308-311 ISSN 0168-583X. [21st International Conference on Ion Beam Analysis (IBA). Seattle, 23.06.2013-28.06.2013] R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : ion energy loss spectrometry * single ion track * microprobe * tomography Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.124, year: 2014

  9. Total quantitative recording of elemental maps and spectra with a scanning microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; Hammond, I.

    1979-01-01

    A system of data recording and analysis has been developed by means of which simultaneously all data from a scanning instrument such as a microprobe can be quantitatively recorded and permanently stored, including spectral outputs from several detectors. Only one scanning operation is required on the specimen. Analysis is then performed on the stored data, which contain quantitative information on distributions of all elements and spectra of all regions

  10. Application of the microprobe dredging operation in the treatment of the meibomian gland dysfunction(MGD

    Directory of Open Access Journals (Sweden)

    Qing-Qiang Wang

    2014-07-01

    Full Text Available AIM: To evaluate the function of the microprobe dredging technology in the treatment of meibomian gland dysfunction(MGDand to provide fast, efficient, economical and practical method of treatment for meibomian gland dysfunction(MGD. METHODS:The 100μm diameter stainless steel wire was made as the microprobe with the total length of 3cm, which the needle was about 5mm and hand shank was about 2.5cm. Selected 140 cases with dry eyes of meibomian gland dysfunction(MGD, patients were divided into two groups and made them have comparability. Observation group(n=70used microprobe to dredge meibomian gland pipe accompanied with drugs, hot compress and meibomian gland massage treatment. The control group(n=70was given conventional drugs, hot compress and meibomian massage treatment. To compare the tear break-up time(BUT, efficient rate and the cure rate of the two groups after treatment of 1d, 1wk, 2wk, 1 mo, 2mo and 3mo.RESULTS: BUT were significantly prolonged in observation group and control group after treatment, and the observation group improved more obviously; the efficient rate and cure rate of the observation group were significantly higher than that of the control group after 1d, 1wk, 2wk, 1mo, 2mo and 3mo treatment. CONCLUSION:Using microprobe to unclog the meibomian gland tube can provide the fast and efficient, economical and practical treatment for meibomian gland dysfunction(MGD, which can be promoted in the clinical practice.

  11. Distribution of copper and other elements in ryegrass roots, determined with a scanning proton microprobe

    International Nuclear Information System (INIS)

    Mazzolini, A.P.; Legge, G.J.F.

    1982-01-01

    A scanning proton microprobe has been used to determine the distribution of Cu and other elements in Wimmera ryegrass roots grown in solution cultures. Cu was found to be localized on or near the surface of the roots in randomly distributed discrete zones. The distribution of Cu was partially correlated with those of Fe, P and Ca and possibly indicates some form of association; co-precipitation in a precipitate of ferric phosphate or hydroxy-oxide is favoured

  12. Medipix2 based CdTe microprobe for dental imaging

    International Nuclear Information System (INIS)

    Vykydal, Z; Jakubek, J; Fauler, A; Fiederle, M; Zwerger, A; Svestkova, M

    2011-01-01

    Medical imaging devices and techniques are demanded to provide high resolution and low dose images of samples or patients. Hybrid semiconductor single photon counting devices together with suitable sensor materials and advanced techniques of image reconstruction fulfil these requirements. In particular cases such as the direct observation of dental implants also the size of the imaging device itself plays a critical role. This work presents the comparison of 2D radiographs of tooth provided by a standard commercial dental imaging system (Gendex 765DC X-ray tube with VisualiX scintillation detector) and two Medipix2 USB Lite detectors one equipped with a Si sensor (300 μm thick) and one with a CdTe sensor (1 mm thick). Single photon counting capability of the Medipix2 device allows virtually unlimited dynamic range of the images and thus increases the contrast significantly. The dimensions of the whole USB Lite device are only 15 mm × 60 mm of which 25% consists of the sensitive area. Detector of this compact size can be used directly inside the patients' mouth.

  13. Trace elemental analysis of bituminous coals using the Heidelberg proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J R; Kneis, H; Martin, B; Nobiling, R; Traxel, K [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.); Heidelberg Univ. (Germany, F.R.). Physikalisches Inst.); Chao, E C.T.; Minkin, J A [Geological Survey, Reston, VA (USA)

    1981-03-01

    Trace elements in coal can occur as components of either the organic constituents (macerals) or the inorganic constituents (minerals). Studies of the concentrations and distribution of the trace elements are vital to understanding the geochemical milieu in which the coal was formed and in evaluating the attempts to recover rare but technologically valuable metals. In addition, information on the trace element concentrations is important in predicting the environmental impact of burning particular coals, as many countries move toward greater utilization of coal reserves for energy production. Traditionally, the optical and the electron microscopes and more recently the electron microprobe have been used in studying the components of coal. The proton-induced X-ray emission (PIXE) microprobe offers a new complementary approach with an order of magnitude or more better minimum detection limit. We present the first measurements with a PIXE microprobe of the trace element concentrations of bituminous coal samples. Elemental analyses of the coal macerals-vitrinite, exinite, and inertinite - are discussed for three coal samples from the Eastern U.S.A., three samples from the Western U.S.A., and one sample from the Peoples Republic of China.

  14. The Mars Microprobe Mission: Advanced Micro-Avionics for Exploration Surface

    Science.gov (United States)

    Blue, Randel

    2000-01-01

    The Mars Microprobe Mission is the second spacecraft developed as part of the New Millennium Program deep space missions. The objective of the Microprobe Project is to demonstrate the applicability of key technologies for future planetary missions by developing two probes for deployment on Mars. The probes are designed with a single stage entry, descent, and landing system and impact the Martian surface at speeds of approximately 200 meters per second. The microprobes are composed of two main sections, a forebody section that penetrates to a depth below the Martian surface of 0.5 to 2 meters, and an aftbody section that remains on the surface. Each probe system consists of a number of advanced technology components developed specifically for this mission. These include a non-erosive aeroshell for entry into. the atmosphere, a set of low temperature batteries to supply probe power, an advanced microcontroller to execute the mission sequence, collect the science data, and react to possible system fault conditions, a telecommunications subsystem implemented on a set of custom integrated circuits, and instruments designed to provide science measurements from above and below the Martian surface. All of the electronic components have been designed and fabricated to withstand the severe impact shock environment and to operate correctly at predicted temperatures below -100 C.

  15. Control of heavy loads at nuclear power plants: Resolution of Generic Technical Activity A-36. Technical report

    International Nuclear Information System (INIS)

    George, H.J.

    1980-07-01

    This report summarizes work performed by the NRC staff in the resolution of Generic Technical Activity A-36, Control of Heavy Loads Near Spent Fuel. Generic Technical Activity A-36 is one of the generic technical subjects designated as unresolved safety issues pursuant to Section 210 of the Energy Reorganization Act of 1974. The report describes the technical studies and evaluations performed by the NRC staff, the staff's guidelines based on these studies, and the staff's plans for implementaton of its technical guidelines

  16. Nuclear structure studies using the high resolution spectrometer at the Los Alamos Clinton P. Anderson Meson Physics Facility: Annual progress report, [1987-1988

    International Nuclear Information System (INIS)

    1987-09-01

    This document constitutes the (1987 to 1988) progress report for the ongoing medium energy nuclear physics research program supported by the US Department of Energy with the University of Texas at Austin. A major part of the work has been and will continue to be associated with research done at the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF) using the High Resolution Spectrometer (HRS), the External Proton Beam (EPB), and the new Neutron Time of Flight Facility (NTOF). Other research is done at the Fermi National Accelerator Laboratory (FNAL). The research focuses on (1) providing proton + nucleus data which test nonrelativistic and relativistic models of the medium energy proton + nucleus interaction, (2) providing (p,p) and (p,n) data which are to be analyzed to provide new nuclear structure information (both ground state and excited state), (3) providing nucleon + nucleon data to aid in the systematic study of the fundamental nucleon-nucleon interaction, (4) developing and improving the proton + nucleus theoretical models themselves, and (5) initiating new experimental programs whose goals are to search for new phenomena in nuclear physics. 182 refs., 71 figs., 5 tabs

  17. High resolution positron Q-value measurements and nuclear structure studies far from the stability line. Progress report

    International Nuclear Information System (INIS)

    Avignone, F.T. III.

    1982-01-01

    Research progress in briefly described, and details are presented in the attached preprints and reprints: (1) precision mass differences in light rubidium and krypton isotopes utilizing beta endpoint measurements; (2) precision mass measurements utilizing beta endpoints; (3) Monte Carlo calculations predicting the response of intrinsic GE detectors to electrons and positrons; and (4) reactor antineutrino spectra and nuclear spectroscopy of isotopes far from beta stability

  18. Results from the nuclear microprobe PIXE analysis of selected rare earth fluor compounds

    International Nuclear Information System (INIS)

    Hollerman, William A.; Gates, Earl; Boudreaux, Philip; Glass, Gary A.

    2002-01-01

    Most previous research measures fluorescence properties over the macroscopic regime. Properties of individual microscopic grains could be significantly different than those measured over the macroscopic scale. Until recently, it was difficult to measure properties of individual fluor grains. Existing characterization techniques like scanning electron microscopy are not practical, since the resulting fluorescence masks the electron surface profile. Starting in September 2000, a research program was initiated at the Acadiana Research Laboratory to determine microscopic fluorescence properties for selected inorganic rare earth compounds. The initial phase of this program utilized microscopic proton induced X-ray emission (μPIXE) to characterize the elemental composition of individual fluor grains. Results show that both individual grains and small clusters of grains could be seen using μPIXE. Maps of this type can be used to estimate grain dimensions for the selected rare earth fluor. This technique is a new and innovative method to characterize a fluor material

  19. Study of metal bioaccumulation by nuclear microprobe analysis of algae fossils and living algae cells

    International Nuclear Information System (INIS)

    Guo, P.; Wang, J.; Li, X.; Zhu, J.; Reinert, T.; Heitmann, J.; Spemann, D.; Vogt, J.; Flagmeyer, R.-H.; Butz, T.

    2000-01-01

    Microscopic ion-beam analysis of palaeo-algae fossils and living green algae cells have been performed to study the metal bioaccumulation processes. The algae fossils, both single cellular and multicellular, are from the late Neoproterozonic (570 million years ago) ocean and perfectly preserved within a phosphorite formation. The biosorption of the rare earth element ions Nd 3+ by the green algae species euglena gracilis was investigated with a comparison between the normal cells and immobilized ones. The new Leipzig Nanoprobe, LIPSION, was used to produce a proton beam with 2 μm size and 0.5 nA beam current for this study. PIXE and RBS techniques were used for analysis and imaging. The observation of small metal rich spores (<10 μm) surrounding both of the fossils and the living cells proved the existence of some specific receptor sites which bind metal carrier ligands at the microbic surface. The bioaccumulation efficiency of neodymium by the algae cells was 10 times higher for immobilized algae cells. It confirms the fact that the algae immobilization is an useful technique to improve its metal bioaccumulation

  20. Nuclear microprobe analysis of carbon within glass inclusions and volcanic materials

    International Nuclear Information System (INIS)

    Metrich, N.; Mosbah, M.; Trocellier, P.; Clocchiatti, R.

    1986-01-01

    Microanalysis possibilities have been explored to determine light element concentrations within glasses (melt inclusions and basaltic glass fragments) and volcanic phenocrysts. In the first step, C was examined. The study of different spectral interferences lead to calculated detection limits of 40 μg/g for basaltic glasses and 50 μg/g for olivine crystals. The C contents of all investigated specimens range from 40 μg/g (the detection limit) to 6800 μg/g. Heterogeneities were revealed within glass inclusions. Measurements show obvious concentration profiles in basaltic glass samples. Our results agree with previous published data and are reliable. Accuracy of measurements is about 20%. 12 refs

  1. Application of a nuclear microprobe to the study of fish otoliths and scales

    International Nuclear Information System (INIS)

    Coote, G.E.; Gauldie, R.W.; West, I.F.

    1991-01-01

    We have measured the distributions of some of the elements in otoliths and scales from several species of teleost (bony) fish, with the aim of learning more about the environment of a fish at different stages in its life, and testing the validity of present methods for determining the age of a fish. The ratio of strontium to calcium in successive layers of an otolith is extremely sensitive to water temperature, so it is possible to trace the temperature history of the fish, probably including seasonal variations. The distributions of calcium and fluorine in scales differ strikingly between species and sufficiently in a single scale to suggest that environmental information may be captured there as well. (orig.)

  2. Hydrogen study in melt inclusions trapped in quartz with nuclear microprobe

    International Nuclear Information System (INIS)

    Mosbah, M.; Tirira, J.; Gosset, J.; Massiot, P.

    1990-01-01

    Elastic recoil spectrometry induced by 3 MeV helium-4 microbeam has been used to determine hydrogen distribution within melt inclusions trapped in quartz. These minerals were selected from different geological environments: Guadeloupe (West Indies), Pantelleria Island (South Sicily - Italy) and San Pietro (South Sardinia - Italy). Bulk hydrogen contents are calculated (H assumed to be in H 2 O form). The knowledge of hydrogen distribution assists both in a better understanding and in the establishment of volcanic dynamism hypotheses. Finally, fluid hydrogen rich inclusions are evidenced and H concentration profile is simulated and reported for the first time in glass inclusion

  3. Study of Italian Renaissance sculptures using an external beam nuclear microprobe

    Science.gov (United States)

    Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J. R.

    2000-03-01

    The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented.

  4. Study of Italian Renaissance sculptures using an external beam nuclear microprobe

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J.R.

    2000-01-01

    The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented

  5. Determination of xenon in irradiated nuclear fuel using a shielded electron microprobe

    International Nuclear Information System (INIS)

    Jenson, E.D.

    1983-06-01

    The technique described produces a semi-quantitative determination of the distribution of xenon present in a section of fuel pin along a predetermined line. The x-ray counting technique chosen is to drive the spectrometer over the peak in small increments, counting at each step, then to integrate the resulting data over the entire peak. Counting times are usually 10 sec at each step and there are 30 to 40 steps over a peak. Interferences and possible loss of Xe due to local heating are discussed. Comparison with independent analysis is presented

  6. The identification of growth lines in abalone shell using a nuclear microprobe

    International Nuclear Information System (INIS)

    Bettiol, A.A.; Yang, C.; Hawkes, G.P.; Jamieson, D.N.; Malmqvist, K.G.; Day, R.W.

    1999-01-01

    Ionoluminescence (IL) combined with particle induced X-ray emission (PIXE) imaging has been employed to identify intrinsic growth bands in the spire region, and extrinsic bands at the growth edge of Australian Black-lip abalone shell (Haliotis rubra). Previous studies using optical flood cathodoluminescence, scanning electron microscope cathodoluminescence (SEM-CL) and Raman spectroscopy on samples from the same population suggest that the visible luminescence is due to Mn 2+ activated calcium carbonate. In this study we confirm Mn 2+ as the activator in both the spire and growth edge regions of the shell. The sensitivity of ionoluminescence to the co-ordination environment of the Mn 2+ activators in the shell allows for the spatial identification of the calcium carbonate polymorph responsible for the growth lines observed optically. Furthermore the detection and mapping of trace elements such as Mn and Sr with the PIXE technique enables comparisons to be made between calcite and aragonite biomineralized in the wild and under laboratory conditions

  7. The identification of growth lines in abalone shell using a nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A.; Yang, C.; Hawkes, G.P.; Jamieson, D.N. E-mail: dnj@physics.unimelb.edu.au; Malmqvist, K.G.; Day, R.W

    1999-09-02

    Ionoluminescence (IL) combined with particle induced X-ray emission (PIXE) imaging has been employed to identify intrinsic growth bands in the spire region, and extrinsic bands at the growth edge of Australian Black-lip abalone shell (Haliotis rubra). Previous studies using optical flood cathodoluminescence, scanning electron microscope cathodoluminescence (SEM-CL) and Raman spectroscopy on samples from the same population suggest that the visible luminescence is due to Mn{sup 2+} activated calcium carbonate. In this study we confirm Mn{sup 2+} as the activator in both the spire and growth edge regions of the shell. The sensitivity of ionoluminescence to the co-ordination environment of the Mn{sup 2+} activators in the shell allows for the spatial identification of the calcium carbonate polymorph responsible for the growth lines observed optically. Furthermore the detection and mapping of trace elements such as Mn and Sr with the PIXE technique enables comparisons to be made between calcite and aragonite biomineralized in the wild and under laboratory conditions.

  8. Nuclear

    International Nuclear Information System (INIS)

    2014-01-01

    This document proposes a presentation and discussion of the main notions, issues, principles, or characteristics related to nuclear energy: radioactivity (presence in the environment, explanation, measurement, periods and activities, low doses, applications), fuel cycle (front end, mining and ore concentration, refining and conversion, fuel fabrication, in the reactor, back end with reprocessing and recycling, transport), the future of the thorium-based fuel cycle (motivations, benefits and drawbacks), nuclear reactors (principles of fission reactors, reactor types, PWR reactors, BWR, heavy-water reactor, high temperature reactor of HTR, future reactors), nuclear wastes (classification, packaging and storage, legal aspects, vitrification, choice of a deep storage option, quantities and costs, foreign practices), radioactive releases of nuclear installations (main released radio-elements, radioactive releases by nuclear reactors and by La Hague plant, gaseous and liquid effluents, impact of releases, regulation), the OSPAR Convention, management and safety of nuclear activities (from control to quality insurance, to quality management and to sustainable development), national safety bodies (mission, means, organisation and activities of ASN, IRSN, HCTISN), international bodies, nuclear and medicine (applications of radioactivity, medical imagery, radiotherapy, doses in nuclear medicine, implementation, the accident in Epinal), nuclear and R and D (past R and D programmes and expenses, main actors in France and present funding, main R and D axis, international cooperation)

  9. A high-resolution, multi-stop, time-to-digital converter for nuclear time-of-flight measurements

    International Nuclear Information System (INIS)

    Spencer, D.F.; Cole, J.; Drigert, M.; Aryaeinejad, R.

    2006-01-01

    A high-resolution, multi-stop, time-to-digital converter (TDC) was designed and developed to precisely measure the times-of-flight (TOF) of incident neutrons responsible for induced fission and capture reactions on actinide targets. The minimum time resolution is ±1 ns. The TDC design was implemented into a single, dual-wide CAMAC module. The CAMAC bus is used for command and control as well as an alternative data output. A high-speed ECL interface, compatible with LeCroy FERA modules, was also provided for the principle data output path. An Actel high-speed field programmable gate array (FPGA) chip was incorporated with an external oscillator and an internal multiple clock phasing system. This device implemented the majority of the high-speed register functions, the state machine for the FERA interface, and the high-speed counting circuit used for the TDC conversion. An external microcontroller was used to monitor and control system-level changes. In this work we discuss the performance of this TDC module as well as its application

  10. Isotopic Investigations of Nebular and Parent Body Processes with a High Sensitivity Ion Microprobe

    Science.gov (United States)

    McKeegan, Kevin D.

    2005-01-01

    NASA supported the development of the CAMECA ims 1270 ion microprobe at UCLA for applications in cosmochemistry. The primary investigations centered on measuring the microscopic distributions of key isotopic abundances in primitive meteoritic materials as a means of constraining the nature of important thermal and chemical processes in the solar nebula and the timescales associated with those processes. Our prior work on oxygen isotope anomalies in a wide variety of meteoritic materials had led us to a view of a spatially heterogeneous nebula, and in particular, a restricted region for CAI formation that is characterized by O-16-rich gas. Because of its production of CAIs in the energetic local environment near the protosun, the existence of a natural transport mechanism via bipolar outflows, and a general astrophysical plausibility, we were attracted to the fluctuating X-wind model which had been put forward by Frank Shu, Typhoon Lee, and colleagues. With our collaborators, we undertook a series of investigations to test the viability of this hypothesis; this work led directly to the discovery of live Be in CAIs and a clear demonstration of the existence of 160-rich condensates, which necessarily implies an O-16-rich gaseous reservoir in the nebula. Both of these observations fit well within the context of X-wind type models, i.e. formation of CAIs (or condensation of their precursors) in the reconnection ring sunward of the inner edge of the accretion disk, however much work remains to be done to test whether the physical parameters of the model can quantitatively predict not only the thermal histories of CAIs but also their radioactivity. The issue of spatial heterogeneity in the nebula, central to the X-wind model, is also at the heart of any chronology based on short-lived radioisotopes. In this work, we followed up on strong hints for presence of exireme:j: (53 day) short-lived Be-7, and have prepared a manuscript (in revision). We also measured A1-Mg

  11. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Piotto Martial

    2012-01-01

    Full Text Available Abstract Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9 originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample. Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater.

  12. Use of X-ray microprobe to diagnose bone tissue demineralization after caffeine administration Use of X-ray microprobe to diagnose bone tissue demineralization after caffeine administration

    Directory of Open Access Journals (Sweden)

    Marek Tomaszewski

    2012-10-01

    Full Text Available Caffeine is a methylxanthine which permeates the placenta. In studies on animals, it has been
    shown to produce teratogenic and embryotoxic effects in large doses. The objective of this study was to
    assess the influence of caffeine on the development of bone tissue, with particular reference to elemental
    bone composition using an X-ray microprobe. The research was conducted on rats. The fertilized females
    were randomly divided into an experimental and a control group. The experimental group was
    given caffeine orally in 30 mg/day doses from the 8th to the 21st day of pregnancy, while the control group
    was given water. The fetuses were used to assess the growth and mineralization of the skeleton. On the
    basis of double dyeing, a qualitative analysis of the bone morphology and mineralization was conducted.
    For calcium and potassium analysis, an X-ray microprobe was used. In 67 fetuses from the experimental
    group, changes in skeleton staining with the alcian-alizarin method were noticed. The frequency of the
    development of variants in the experimental group was statistically higher. In the experimental group,
    a significant decrease in the calcium level, as well as an increase in the potassium level, was observed.
    The X-ray microprobe’s undoubted advantage is that is offers a quick qualitative and quantitative analysis
    of the elemental composition of the examined samples. Employing this new technique may furnish us
    with new capabilities when investigating the essence of the pathology process.Caffeine is a methylxanthine which permeates the placenta. In studies on animals, it has been
    shown to produce teratogenic and embryotoxic effects in large doses. The objective of this study was to
    assess the influence of caffeine on the development of bone tissue, with particular reference to elemental
    bone composition using an X-ray microprobe. The research was conducted on

  13. Survey of university students' knowledge and views on nuclear waste disposal and the alternative dispute resolution process

    International Nuclear Information System (INIS)

    Sheng, G.; Deffner, L.; Fiorini, S.

    1996-01-01

    The management of the high level radioactive waste is an issue which generates multifaceted conflicts. These conflicts are multi-determined, but are nonetheless, based on a myriad of associated concerns including but not exclusive to: effects of radiation on public health and safety, uncertainty associated with long-term assessments and effects, confidence in technology and in government and industry to protect public health and safety, and concerns regarding concurrent and intergenerational equity. These concerns are likely to be deeply felt by the many potential actors and stakeholders who will be impacted during the process of site selection for a nuclear waste disposal facility. Because this site selection is sure to be a controversial undertaking, it is in the interests of those who wish to promote the use of the high-level radioactive waste disposal concept, to understand fully the potential for conflict and consider alternative means of proactively preventing and/or resolving conflicts

  14. Development of nuclear emulsions with 1μm spatial resolution for the AEgIS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, M. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern, 3012 Bern (Switzerland); Aghion, S. [Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sez. di Milano, Via Celoria 16, 20133 Milano (Italy); Ahlén, O. [European Organisation for Nuclear Research, Physics Department, 1211 Geneva 23 (Switzerland); Amsler, C., E-mail: claude.amsler@cern.ch [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern, 3012 Bern (Switzerland); Ariga, A.; Ariga, T. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern, 3012 Bern (Switzerland); Belov, A.S. [Institute for Nuclear Research of the Russian Academy of Sciences, Moscow 117312 (Russian Federation); Bonomi, G. [University of Brescia, Department of Mechanical and Industrial Engineering, Via Branze 38, 25133 Brescia (Italy); Istituto Nazionale di Fisica Nucleare, Sez. di Pavia, Via Agostino Bassi 6, 27100 Pavia (Italy); Bräunig, P. [University of Heidelberg, Kirchhoff Institute for Physics, Im Neuenheimer Feld 227, 69120 Heidelberg (Germany); Bremer, J. [European Organisation for Nuclear Research, Physics Department, 1211 Geneva 23 (Switzerland); Brusa, R.S. [Dipartimento di Fisica, Università di Trento and INFN, Gruppo Collegato di Trento, Via Sommarive 14, 38050 Povo, Trento (Italy); Burghart, G. [European Organisation for Nuclear Research, Physics Department, 1211 Geneva 23 (Switzerland); Cabaret, L. [Laboratoire Aimé Cotton, CNRS, Université Paris Sud, ENS Cachan, Bâtiment 505, Campus d' Orsay, 91405 Orsay Cedex (France); Canali, C. [University of Zurich, Physics Institute, Winterthurerstrasse 190, 8057 Zurich (Switzerland); and others

    2013-12-21

    The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. We will measure the Earth's gravitational acceleration g{sup ¯} with antihydrogen atoms being launched in a horizontal vacuum tube and traversing a moiré deflectometer. We intend to use a position sensitive device made of nuclear emulsions (combined with a time-of-flight detector such as silicon μ-strips) to measure precisely their annihilation points at the end of the tube. The goal is to determine g{sup ¯} with a 1% relative accuracy. In 2012 we tested emulsion films in vacuum and at room temperature with low energy antiprotons from the CERN antiproton decelerator. First results on the expected performance for AEgIS are presented.

  15. Development of nuclear emulsions with 1 $\\mu$m spatial resolution for the AEgIS experiment

    CERN Document Server

    Kimura, M; Ahlén, O; Amsler, C; Ariga, A; Ariga, T; Belov, A.S; Bonomi, G; Bräunig, P; Bremer, J; Brusa, R.S; Burghart, G; Cabaret, L; Canali, C; Caravita, R; Castelli, F; Cerchiari, G; Cialdi, S; Comparat, D; Consolati, G; Di Domizio, S; Di Noto, L; Doser, M; Dudarev, A; Ereditato, A; Ferragut, R; Fontana, A; Genova, P; Giammarchi, M; Gligorova, A; Gninenko, S.N; Haider, S; Hogan, S.D; Huse, T; Jordan, E; Jørgensen, L.V; Kaltenbacher, T; Kawada, J; Kellerbauer, A; Knecht, A; Krasnický, D; Lagomarsino, V; Mariazzi, S; Matveev, V.A; Merkt, F; Moia, F; Nebbia, G; Nédélec, P; Oberthaler, M.K; Pacifico, N; Petrácek, V; Pistillo, C; Prelz, F; Prevedelli, M; Regenfus, C; Riccardi, C; Røhne, O; Rotondi, A; Sandaker, H; Scampoli, P; Spacek, M; Storey, J; Subieta Vasquez, M.A; Testera, G; Trezzi, D; Vaccarone, R; Zavatarelli, S

    2013-01-01

    The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. We will measure the Earth ' s gravitational acceleration g with antihydrogen atoms being launched in a horizontal vacuum tube and traversing a moiré de fl ectometer. We intend to use a position sensitive device made of nuclear emulsions (combined with a time-of- fl ight detector such as silicon μ strips) to measure precisely their annihilation points at the end of the tube. The goal is to determine g with a 1% relative accuracy. In 2012 we tested emulsion fi lms in vacuum and at room temperature with low energy antiprotons from the CERN antiproton decelerator. First results on the expected performance for AEgIS are presented

  16. What Perspectives for Crisis Resolution? Which European Diplomacy vis-a-vis Iran's Nuclear Ambitions?

    International Nuclear Information System (INIS)

    Moscovici, Pierre

    2008-01-01

    The conduct of European diplomacy on the Iranian dossier raises many geopolitical issues. What are the strategic possibilities for the European Union? Its credibility is at stake and it must now demonstrate that its alternative approach is more efficient than American policy, which seeks to use the Iranian nuclear dispute as an element of struggle against the Iranian regime. However, the multiplicity of decision-making structures of the EU foreign policy make more complex its action and the implementation of its policies, that are articulated between diplomatic efforts and threats of sanctions. Where the United States has chosen containment, the EU chooses the commitment and sees the return to dialogue and stabilization possible

  17. New possibility for high-resolution spectroscopy of nuclear particles entering CR-39 at selected dip angles

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Hunyadi, I.; Hafez, A.F. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete); Espinosa, G. (Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Fisica)

    1984-01-01

    In nuclear reaction studies a differentiation of the reaction products according to their type and energy is generally required. At right angle of incidence a particle identification method based on the relation between the track diameter and particle energy can be well applied to plastic track detectors of low registration sensitivity. We have tried to extend this 'track-diameter method' to the high-sensitivity CR-39 sheets by selecting special incident angles for particle detection. The utility of such a measuring procedure, called 'track-size method', is presented for alpha and proton spectroscopy. A theory is developed to calculate at arbitrary angles the main parameters affecting the energy resolving power of the 'track-size method', namely the critical layer thickness (which has to be removed from the detector surface for track-induction) and the depth and minor axis of etch-pits.

  18. Azimuthally anisotropic hydride lens structures in Zircaloy 4 nuclear fuel cladding: High-resolution neutron radiography imaging and BISON finite element analysis

    Science.gov (United States)

    Lin, Jun-Li; Zhong, Weicheng; Bilheux, Hassina Z.; Heuser, Brent J.

    2017-12-01

    High-resolution neutron radiography has been used to image bulk circumferential hydride lens particles in unirradiated Zircaloy 4 tubing cross section specimens. Zircaloy 4 is a common light water nuclear reactor (LWR) fuel cladding; hydrogen pickup, hydride formation, and the concomitant effect on the mechanical response are important for LWR applications. Ring cross section specimens with three hydrogen concentrations (460, 950, and 2830 parts per million by weight) and an as-received reference specimen were imaged. Azimuthally anisotropic hydride lens particles were observed at 950 and 2830 wppm. The BISON finite element analysis nuclear fuel performance code was used to model the system elastic response induced by hydride volumetric dilatation. The compressive hoop stress within the lens structure becomes azimuthally anisotropic at high hydrogen concentrations or high hydride phase fraction. This compressive stress anisotropy matches the observed lens anisotropy, implicating the effect of stress on hydride formation as the cause of the observed lens azimuthal asymmetry. The cause and effect relation between compressive stress and hydride lens anisotropy represents an indirect validation of a key BISON output, the evolved hoop stress associated with hydride formation.

  19. A report on high-level nuclear waste transportation: Prepared pursuant to assembly concurrent resolution No. 8 of the 1987 Nevada Legislature

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-01

    This report has been prepared by the staff of the State of Nevada Agency for Nuclear Projects/Nuclear Waste Project Office (NWPO) in response to Assembly Concurrent Resolution No. 8 (ACR 8), passed by the Nevada State Legislature in 1987. ACR 8 directed the NWPO, in cooperation with affected local governments and the Legislative committee on High-Level Radioactive Waste, to prepare this report which scrutinizes the US Department of Energy`s (DOE) plans for transportation of high-level radioactive waste to the proposed yucca Mountain repository, which reviews the regulatory structure under which shipments to a repository would be made and which presents NWPO`s plans for addressing high-level radioactive waste transportation issues. The report is divided into three major sections. Section 1.0 provides a review of DOE`s statutory requirements, its repository transportation program and plans, the major policy, programmatic, technical and institutional issues and specific areas of concern for the State of Nevada. Section 2.0 contains a description of the current federal, state and tribal transportation regulatory environment within which nuclear waste is shipped and a discussion of regulatory issues which must be resolved in order for the State to minimize risks and adverse impacts to its citizens. Section 3.0 contains the NWPO plan for the study and management of repository-related transportation. The plan addresses four areas, including policy and program management, regulatory studies, technical reviews and studies and institutional relationships. A fourth section provides recommendations for consideration by State and local officials which would assist the State in meeting the objectives of the plan.

  20. A report on high-level nuclear waste transportation: Prepared pursuant to assembly concurrent resolution No. 8 of the 1987 Nevada Legislature

    International Nuclear Information System (INIS)

    1988-12-01

    This report has been prepared by the staff of the State of Nevada Agency for Nuclear Projects/Nuclear Waste Project Office (NWPO) in response to Assembly Concurrent Resolution No. 8 (ACR 8), passed by the Nevada State Legislature in 1987. ACR 8 directed the NWPO, in cooperation with affected local governments and the Legislative committee on High-Level Radioactive Waste, to prepare this report which scrutinizes the US Department of Energy's (DOE) plans for transportation of high-level radioactive waste to the proposed yucca Mountain repository, which reviews the regulatory structure under which shipments to a repository would be made and which presents NWPO's plans for addressing high-level radioactive waste transportation issues. The report is divided into three major sections. Section 1.0 provides a review of DOE's statutory requirements, its repository transportation program and plans, the major policy, programmatic, technical and institutional issues and specific areas of concern for the State of Nevada. Section 2.0 contains a description of the current federal, state and tribal transportation regulatory environment within which nuclear waste is shipped and a discussion of regulatory issues which must be resolved in order for the State to minimize risks and adverse impacts to its citizens. Section 3.0 contains the NWPO plan for the study and management of repository-related transportation. The plan addresses four areas, including policy and program management, regulatory studies, technical reviews and studies and institutional relationships. A fourth section provides recommendations for consideration by State and local officials which would assist the State in meeting the objectives of the plan

  1. In vivo optical microprobe imaging for intracellular Ca2+ dynamics in response to dopaminergic signaling in deep brain evoked by cocaine

    Science.gov (United States)

    Luo, Zhongchi; Pan, Yingtian; Du, Congwu

    2012-02-01

    Ca2+ plays a vital role as second messenger in signal transduction and the intracellular Ca2+ ([Ca2+]i) change is an important indicator of neuronal activity in the brain, including both cortical and subcortical brain regions. Due to the highly scattering and absorption of brain tissue, it is challenging to optically access the deep brain regions (e.g., striatum at >3mm under the brain surface) and image [Ca2+]i changes with cellular resolutions. Here, we present two micro-probe approaches (i.e., microlens, and micro-prism) integrated with a fluorescence microscope modified to permit imaging of neuronal [Ca2+]i signaling in the striatum using a calcium indicator Rhod2(AM). While a micro-prism probe provides a larger field of view to image neuronal network from cortex to striatum, a microlens probe enables us to track [Ca2+]i dynamic change in individual neurons within the brain. Both techniques are validated by imaging neuronal [Ca2+]i changes in transgenic mice with dopamine receptors (D1R, D2R) expressing EGFP. Our results show that micro-prism images can map the distribution of D1R- and D2R-expressing neurons in various brain regions and characterize their different mean [Ca2+]i changes induced by an intervention (e.g., cocaine administration, 8mg/kg., i.p). In addition, microlens images can characterize the different [Ca2+]i dynamics of D1 and D2 neurons in response to cocaine, including new mechanisms of these two types of neurons in striatum. These findings highlight the power of the optical micro-probe imaging for dissecting the complex cellular and molecular insights of cocaine in vivo.

  2. Nuclear protein accumulation in cellular senescence and organismal aging revealed with a novel single-cell resolution fluorescence microscopy assay.

    Science.gov (United States)

    De Cecco, Marco; Jeyapalan, Jessie; Zhao, Xiaoai; Tamamori-Adachi, Mimi; Sedivy, John M

    2011-10-01

    Replicative cellular senescence was discovered some 50 years ago. The phenotypes of senescent cells have been investigated extensively in cell culture, and found to affect essentially all aspects of cellular physiology. The relevance of cellular senescence in the context of age-associated pathologies as well as normal aging is a topic of active and ongoing interest. Considerable effort has been devoted to biomarker discovery to enable the microscopic detection of single senescent cells in tissues. One characteristic of senescent cells documented very early in cell culture studies was an increase in cell size and total protein content, but whether this occurs in vivo is not known. A limiting factor for studies of protein content and localization has been the lack of suitable fluorescence microscopy tools. We have developed an easy and flexible method, based on the merocyanine dye known as NanoOrange, to visualize and quantitatively measure total protein levels by high resolution fluorescence microscopy. NanoOrange staining can be combined with antibody-based immunofluorescence, thus providing both specific target and total protein information in the same specimen. These methods are optimally combined with automated image analysis platforms for high throughput analysis. We document here increasing protein content and density in nuclei of senescent human and mouse fibroblasts in vitro, and in liver nuclei of aged mice in vivo. Additionally, in aged liver nuclei NanoOrange revealed protein-dense foci that colocalize with centromeric heterochromatin.

  3. Detection and quantification of phenolic compounds in olive oil by high resolution {sup 1}H nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Christophoridou, Stella [NMR Laboratory, Department of Chemistry, University of Crete, P.O. Box 2208, Voutes, 71003 Heraklion, Crete (Greece); Dais, Photis [NMR Laboratory, Department of Chemistry, University of Crete, P.O. Box 2208, Voutes, 71003 Heraklion, Crete (Greece)], E-mail: dais@chemistry.uoc.gr

    2009-02-09

    High resolution {sup 1}H NMR spectroscopy has been employed as a versatile and rapid method to analyze the polar fraction of extra virgin olive oils containing various classes of phenolic compounds. The strategy for identification of phenolic compounds is based on the NMR chemical shifts of a large number of model compounds assigned by using two-dimensional (2D) NMR spectroscopy. Furthermore, 2D NMR was applied to phenolic extracts in an attempt to discover additional phenolic compounds. The {sup 1}H NMR methodology was successful in detecting simple phenols, such as p-coumaric acid, vanillic acid, homovanillyl alcohol, vanillin, free tyrosol, and free hydroxytyrosol, the flavonols apigenin and luteolin, the lignans (+) pinoresinol, (+) 1-acetoxypinoresinol and syringaresinol, two isomers of the aldehydic form of oleuropein and ligstroside, the dialdehydic form of oleuropein and ligstroside lacking a carboxymethyl group, and finally total hydroxytyrosol and total tyrosol reflecting the total amounts of free and esterified hydroxytyrol and tyrosol, respectively. The absolute amount of each phenolic constituent was determined in the polar fraction by using anhydrous 1,3,5-triazine as an internal standard.

  4. Detection and quantification of phenolic compounds in olive oil by high resolution 1H nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Christophoridou, Stella; Dais, Photis

    2009-01-01

    High resolution 1 H NMR spectroscopy has been employed as a versatile and rapid method to analyze the polar fraction of extra virgin olive oils containing various classes of phenolic compounds. The strategy for identification of phenolic compounds is based on the NMR chemical shifts of a large number of model compounds assigned by using two-dimensional (2D) NMR spectroscopy. Furthermore, 2D NMR was applied to phenolic extracts in an attempt to discover additional phenolic compounds. The 1 H NMR methodology was successful in detecting simple phenols, such as p-coumaric acid, vanillic acid, homovanillyl alcohol, vanillin, free tyrosol, and free hydroxytyrosol, the flavonols apigenin and luteolin, the lignans (+) pinoresinol, (+) 1-acetoxypinoresinol and syringaresinol, two isomers of the aldehydic form of oleuropein and ligstroside, the dialdehydic form of oleuropein and ligstroside lacking a carboxymethyl group, and finally total hydroxytyrosol and total tyrosol reflecting the total amounts of free and esterified hydroxytyrol and tyrosol, respectively. The absolute amount of each phenolic constituent was determined in the polar fraction by using anhydrous 1,3,5-triazine as an internal standard

  5. Cometary and interstellar dust grains - Analysis by ion microprobe mass spectrometry and other techniques

    Science.gov (United States)

    Zinner, Ernst

    1991-01-01

    A survey of microanalytical measurements on interplanetary dust particles (IDPs) and interstellar dust grains from primitive meteorites is presented. Ion-microprobe mass spectrometry with its capability to determine isotopic compositions of many elements on a micron spatial scale has played a special role. Examples are measurements of H, N, and O isotopes and refractory trace elements in IDPs; C, N, Mg, and Si isotopes in interstellar SiC grains; and C and N isotopes and H, N, Al, and Si concentrations in interstellar graphite grains.

  6. A digital squarer system for positive mass identification on the ARL ion microprobe mass analyser

    International Nuclear Information System (INIS)

    Woods, K.N.; Grant, L.D.V.; Rawsthorne, E.D.; Strydom, H.J.; Gries, W.H.

    1984-01-01

    The original analogue squarer for mass scale linearisation in the Ion Microprobe Mass Analyser (IMMA) has been replaced by a programmable digital squarer system which permits reliable mass number identification throughout the tested range 1 to 240. The digital squarer provides signals to both a digital direct reading mass number display and to an X-Y recorder where it provides a linear mass scale correct to within 0,3 mass units. An additional output to a computer can provide binary or BCD mass number data

  7. X-ray microprobe measurements of the chemical compositions of ALH84001 carbonate globules

    International Nuclear Information System (INIS)

    Flynn, G.J.; Sutton, S.R.; Keller, L.P.

    2004-01-01

    We measured minor element contents of carbonate from ALH84001 and report trends in tbe Ca, V, Mn and Sr in carbonate and the associated magnetite bands. McKay et al. suggested that carbonate globules in the ALH84001 meteorite from Mars contained evidence consistent with the development of bacterial life early in the history of Mars. This result provoked an extensive study of the ALH84001 meteorite. More recently Thomas-Keprta et al. have published a study showing that the magnetite associated with carbonate rims are of the size and shape produced by terrestrial bacteria. This paper has revived interest in ALH84001. The typical ALH84001 carbonate globule consists of four regions: a core of Fe-rich carbonate, a thin magnetite-rich band, a rim of Mn-rich carbonate, and another thin magnetite-rich band. Trace element analysis of each of these phases may allow us to address several important questions about these carbonates: (1) The origin of the magnetite-rich bands in the ALH84001 carbonate globules. If the magnetites are derived from the underlying carbonate through thermal decomposition (as proposed by Golden et al.), then we expect to see 'inherited' trace elements in these magnetite bands. (2) The origin of the rim carbonate, by determining whether the carbonate in the core has the same trace elements as the rim carbonates. (3) The age of the rim carbonate. Borg et al. dated the formation of the rim carbonate using the Rb/Sr chronometer. Borg et al. performed their measurements on an aliquot of what they called a high-Rb, low-Sr carbonate separate from the rim. We previously measured the trace element contents of chips from core and rim carbonates from an ALH84001 carbonate globule using an X-Ray Microprobe on Beamline X26A at the National Synchrotron Light Source. These measurements showed the rim carbonate had a very low Rb content, with Sr>>Rb, inconsistent with the ∼5 ppm Rb reported by Borg et al. in the sample they dated by the Rb/Sr chronometer. The large

  8. Individual precipitates in Al alloys probed by the Bonn positron microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Balarisi, Osman; Eich, Patrick; Haaks, Matz; Klobes, Benedikt; Korff, Bjoern; Maier, Karl; Sottong, Reinhard [Helmholtz-Institut fuer Strahlen- und Kernphysik, Nussallee 14-16, 53115 Bonn (Germany); Huehne, Sven-Martin; Mader, Werner [Institut fuer Anorganische Chemie, Roemerstrasse 164, 53117 Bonn (Germany); Staab, Torsten [Fraunhofer ISC, Neunerplatz 2, 97082 Wuerzburg (Germany)

    2010-07-01

    Positron annihilation spectroscopy (PAS) is a unique tool for the characterization of open-volume defects such as vacancies. Therefore, age hardenable Al alloys, whose decomposition is mainly driven by the vacancy mechanism of diffusion, are often characterized by PAS techniques. Nevertheless, probing the defect state of individual precipitates grown in Al alloys requires a focused positron beam and has not been carried out up to now. In this respect we present the first investigations of the defect state of individual precipitates utilizing the Bonn Positron Microprobe (BPM). Furthermore, the analysis of the experimental data has to be facilitated by theoretical calculations of the observables of positron annihilation spectroscopy.

  9. $ANBA; a rapid, combined data acquisition and correction program for the SEMQ electron microprobe

    Science.gov (United States)

    McGee, James J.

    1983-01-01

    $ANBA is a program developed for rapid data acquisition and correction on an automated SEMQ electron microprobe. The program provides increased analytical speed and reduced disk read/write operations compared with the manufacturer's software, resulting in a doubling of analytical throughput. In addition, the program provides enhanced analytical features such as averaging, rapid and compact data storage, and on-line plotting. The program is described with design philosophy, flow charts, variable names, a complete program listing, and system requirements. A complete operating example and notes to assist in running the program are included.

  10. Applications of petrography and electron microprobe analysis to the study of Indian stone sculpture

    International Nuclear Information System (INIS)

    Newman, R.

    1992-01-01

    Examples of research on ancient Indian stone artefacts utilizing petrographic examination coupled with qualitative and quantitative electron beam microprobe analysis of specific minerals are described. Types of artefacts discussed include Gandharan schist sculptures, Pala dynasty phyllite and schist objects from eastern India. Hoysala sculptures from Karnataka state (southern India), and sandstone objects from northern India. In spite of the rich history of stone sculpture in the Indian subcontinent, characterization studies to date have been limited in scope, typically involving unprovenanced artefacts. The examples described point to areas in which more extensive research could produce useful information for the provenancing of artefacts. (author)

  11. Direct observation of low energy nuclear spin excitations in HoCrO3 by high resolution neutron spectroscopy.

    Science.gov (United States)

    Chatterji, T; Jalarvo, N; Kumar, C M N; Xiao, Y; Brückel, Th

    2013-07-17

    We have investigated low energy nuclear spin excitations in the strongly correlated electron compound HoCrO3. We observe clear inelastic peaks at E = 22.18 ± 0.04 μeV in both energy loss and gain sides. The energy of the inelastic peaks remains constant in the temperature range 1.5-40 K at which they are observed. The intensity of the inelastic peak increases at first with increasing temperature and then decreases at higher temperatures. The temperature dependence of the energy and intensity of the inelastic peaks is very unusual compared to that observed in other Nd, Co, V and also simple Ho compounds. Huge quasielastic scattering appears at higher temperatures presumably due to the fluctuating electronic moments of the Ho ions that get increasingly disordered at higher temperatures. The strong quasielastic scattering may also originate in the first Ho crystal-field excitations at about 1.5 meV.

  12. Resolution of deep eudicot phylogeny and their temporal diversification using nuclear genes from transcriptomic and genomic datasets.

    Science.gov (United States)

    Zeng, Liping; Zhang, Ning; Zhang, Qiang; Endress, Peter K; Huang, Jie; Ma, Hong

    2017-05-01

    Explosive diversification is widespread in eukaryotes, making it difficult to resolve phylogenetic relationships. Eudicots contain c. 75% of extant flowering plants, are important for human livelihood and terrestrial ecosystems, and have probably experienced explosive diversifications. The eudicot phylogenetic relationships, especially among those of the Pentapetalae, remain unresolved. Here, we present a highly supported eudicot phylogeny and diversification rate shifts using 31 newly generated transcriptomes and 88 other datasets covering 70% of eudicot orders. A highly supported eudicot phylogeny divided Pentapetalae into two groups: one with rosids, Saxifragales, Vitales and Santalales; the other containing asterids, Caryophyllales and Dilleniaceae, with uncertainty for Berberidopsidales. Molecular clock analysis estimated that crown eudicots originated c. 146 Ma, considerably earlier than earliest tricolpate pollen fossils and most other molecular clock estimates, and Pentapetalae sequentially diverged into eight major lineages within c. 15 Myr. Two identified increases of diversification rate are located in the stems leading to Pentapetalae and asterids, and lagged behind the gamma hexaploidization. The nuclear genes from newly generated transcriptomes revealed a well-resolved eudicot phylogeny, sequential separation of major core eudicot lineages and temporal mode of diversifications, providing new insights into the evolutionary trend of morphologies and contributions to the diversification of eudicots. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  13. Nuclear Physics Group progress report

    International Nuclear Information System (INIS)

    Coote, G.E.

    1985-07-01

    This report summarises the work of the Nuclear Physics Group of the Institute of Nuclear Sciences during the period January-December 1984. Commissioning of the EN-tandem accelerator was completed. The first applications included the production of 13 N from a water target and the measurement of hydrogen depth profiles with a 19 F beam. Further equipment was built for tandem accelerator mass spectrometry but the full facility will not be ready until 1985. The nuclear microprobe on the 3 MV accelerator was used for many studies in archaeometry, metallurgy, biology and materials analysis

  14. Triple aldose reductase/α-glucosidase/radical scavenging high-resolution profiling combined with high-performance liquid chromatography – high-resolution mass spectrometry – solid-phase extraction – nuclear magnetic resonance spectroscopy for identification of antidiabetic constituents in crude, extract of Radix Scutellariae

    DEFF Research Database (Denmark)

    Tahtah, Yousof; Kongstad, Kenneth Thermann; Wubshet, Sileshi Gizachew

    2015-01-01

    high-performance liquid chromatography – high-resolution mass spectrometry – solid-phase extraction – nuclear magnetic resonance spectroscopy. The only α-glucosidase inhibitor was baicalein, whereas main aldose reductase inhibitors in the crude extract were baicalein and skullcapflavone II, and main....../α-glucosidase/radical scavenging high-resolution inhibition profile - allowing proof of concept with Radix Scutellariae crude extract as a polypharmacological herbal drug. The triple bioactivity high-resolution profiles were used to pinpoint bioactive compounds, and subsequent structure elucidation was performed with hyphenated...

  15. Three-dimensional super-resolution microscopy of the inactive X chromosome territory reveals a collapse of its active nuclear compartment harboring distinct Xist RNA foci.

    Science.gov (United States)

    Smeets, Daniel; Markaki, Yolanda; Schmid, Volker J; Kraus, Felix; Tattermusch, Anna; Cerase, Andrea; Sterr, Michael; Fiedler, Susanne; Demmerle, Justin; Popken, Jens; Leonhardt, Heinrich; Brockdorff, Neil; Cremer, Thomas; Schermelleh, Lothar; Cremer, Marion

    2014-01-01

    A Xist RNA decorated Barr body is the structural hallmark of the compacted inactive X territory in female mammals. Using super-resolution three-dimensional structured illumination microscopy (3D-SIM) and quantitative image analysis, we compared its ultrastructure with active chromosome territories (CTs) in human and mouse somatic cells, and explored the spatio-temporal process of Barr body formation at onset of inactivation in early differentiating mouse embryonic stem cells (ESCs). We demonstrate that all CTs are composed of structurally linked chromatin domain clusters (CDCs). In active CTs the periphery of CDCs harbors low-density chromatin enriched with transcriptionally competent markers, called the perichromatin region (PR). The PR borders on a contiguous channel system, the interchromatin compartment (IC), which starts at nuclear pores and pervades CTs. We propose that the PR and macromolecular complexes in IC channels together form the transcriptionally permissive active nuclear compartment (ANC). The Barr body differs from active CTs by a partially collapsed ANC with CDCs coming significantly closer together, although a rudimentary IC channel system connected to nuclear pores is maintained. Distinct Xist RNA foci, closely adjacent to the nuclear matrix scaffold attachment factor-A (SAF-A) localize throughout Xi along the rudimentary ANC. In early differentiating ESCs initial Xist RNA spreading precedes Barr body formation, which occurs concurrent with the subsequent exclusion of RNA polymerase II (RNAP II). Induction of a transgenic autosomal Xist RNA in a male ESC triggers the formation of an 'autosomal Barr body' with less compacted chromatin and incomplete RNAP II exclusion. 3D-SIM provides experimental evidence for profound differences between the functional architecture of transcriptionally active CTs and the Barr body. Basic structural features of CT organization such as CDCs and IC channels are however still recognized, arguing against a uniform

  16. High-resolution nuclear magnetic resonance imaging and single photon emission computerized tomography--cerebral blood flow in a case of pure sensory stroke and mild dementia owing to subcortical arteriosclerotic encephalopathy (Binswanger's disease)

    DEFF Research Database (Denmark)

    De Chiara, S; Lassen, N A; Andersen, A R

    1987-01-01

    hypertensive, 72-year-old patient with PSS, CT scanning and conventional nuclear magnetic resonance imaging (NMRI) scanning using a 7-mm-thick slice on a 1.5 Tesla instrument all failed to visualize the thalamic infarct. Using the high-resolution mode with 2-mm slice thickness it was, however, clearly seen...

  17. PROTON MICROPROBE ANALYSIS OF TRACE-ELEMENT VARIATIONS IN VITRINITES IN THE SAME AND DIFFERENT COAL BEDS.

    Science.gov (United States)

    Minkin, J.A.; Chao, E.C.T.; Blank, Herma; Dulong, F.T.

    1987-01-01

    The PIXE (proton-induced X-ray emission) microprobe can be used for nondestructive, in-situ analyses of areas as small as those analyzed by the electron microprobe, and has a sensitivity of detection as much as two orders of magnitude better than the electron microprobe. Preliminary studies demonstrated that PIXE provides a capability for quantitative determination of elemental concentrations in individual coal maceral grains with a detection limit of 1-10 ppm for most elements analyzed. Encouraged by the earlier results, we carried out the analyses reported below to examine trace element variations laterally (over a km range) as well as vertically (cm to m) in the I and J coal beds in the Upper Cretaceous Ferron Sandstone Member of the Mancos Shale in central Utah, and to compare the data with the data from two samples of eastern coals of Pennsylvanian age.

  18. A hard X-ray scanning microprobe for fluorescence imaging and microdiffraction at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Cai, L.; Lai, B.; Yun, W.; Ilinski, P.; Legnini, D.; Maser, J.; Rodrigues, W.

    1999-01-01

    A hard x-ray scanning microprobe based on zone plate optics and undulator radiation, in the energy region from 6 to 20 keV, has reached a focal spot size (FWHM) of 0.15 microm (v) x 0.6 microm (h), and a photon flux of 4 x 10 9 photons/sec/0.01%BW. Using a slit 44 meters upstream to create a virtual source, a circular beam spot of 0.15 microm in diameter can be obtained with a photon flux of one order of magnitude less. During fluorescence mapping of trace elements in a single human ovarian cell, the microprobe exhibited an imaging sensitivity for Pt (L a line) of 80 attograms/microm 2 for a count rate of 10 counts per second. The x-ray microprobe has been used to map crystallographic strain and multiquantum well thickness in micro-optoelectronic devices produced with the selective area growth technique

  19. Fast probing of glucose and fructose in plant tissues via plasmonic affinity sandwich assay with molecularly-imprinted extraction microprobes.

    Science.gov (United States)

    Muhammad, Pir; Liu, Jia; Xing, Rongrong; Wen, Yanrong; Wang, Yijia; Liu, Zhen

    2017-12-01

    Determination of specific target compounds in agriculture food and natural plant products is essential for many purposes; however, it is often challenging due to the complexity of the sample matrices. Herein we present a new approach called plasmonic affinity sandwich assay for the facile and rapid probing of glucose and fructose in plant tissues. The approach mainly relies on molecularly imprinted plasmonic extraction microprobes, which were prepared on gold-coated acupuncture needles via boronate affinity controllable oriented surface imprinting with the target monosaccharide as the template molecules. An extraction microprobe was inserted into plant tissues under investigation, which allowed for the specific extraction of glucose or fructose from the tissues. The glucose or fructose molecules extracted on the microprobe were labeled with boronic acid-functionalized Raman-active silver nanoparticles, and thus affinity sandwich complexes were formed on the microprobes. After excess Raman nanotags were washed away, the microprobe was subjected to Raman detection. Upon being irradiated with a laser beam, surface plasmon on the gold-coated microprobes was generated, which further produced plasmon-enhanced Raman scattering of the silver-based nanotags and thereby provided sensitive detection. Apple fruits, which contain abundant glucose and fructose, were used as a model of plant tissues. The approach exhibited high specificity, good sensitivity (limit of detection, 1 μg mL -1 ), and fast speed (the whole procedure required only 20 min). The spatial distribution profiles of glucose and fructose within an apple were investigated by the developed approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. X-ray microprobe characterization of materials: the case for undulators on advanced storage rings

    International Nuclear Information System (INIS)

    Sparks, C.J. Jr.

    1984-01-01

    The unique properties of X rays offer many advantages over electrons and other charged particles for the microcharacterization of materials. X rays are more efficient in exciting characteristic X-ray fluorescence and produce higher fluorescent signals to backgrounds than obtained with electrons. Detectable limits for X rays are a few parts per billion and are 10 -3 to 10 -5 less than for electrons. Energy deposition in the sample by X rays is 10 -3 to 10 -4 less than for electrons for the same detectable concentration. High-brightness storage rings, especially in the 6 GeV class with undulators, will be approximately 10 3 brighter in the X-ray energy range from 5 keV to 35 keV than existing storage rings and provide for X-ray microprobes that are as bright as the most advanced electron probes. Such X-ray microprobes will produce unprecedented low levels of detection in diffraction, EXAFS, Auger, and photoelectron spectroscopies for both chemical characterization and elemental identification. These major improvements in microcharacterization capabilities will have wide-ranging ramifications not only in materials science but also in physics, chemistry, geochemistry, biology, and medicine

  1. Data smoothing techniques applied to proton microprobe scans of teleost hard parts

    International Nuclear Information System (INIS)

    West, I.F.; Gauldie, R.W.; Coote, G.E.

    1992-01-01

    We use a proton microprobe to examine the distribution of elements in otoliths and scales of teleost (bony) fish. The elements of principal interest are calcium and strontium in otoliths and calcium and fluorine in scales. Changes in the distribution of these elements across hard structures may allow inferences about the life histories of fish. Otoliths and scales of interest are up to a centimeter in linear dimension and to reveal the structures of interest up to 200 sampling points are required in each dimension. The time needed to accumulate high X-ray counts at each sampling point can be large, particularly for strontium. To reduce microprobe usage we use data smoothing techniques to reveal changing patterns with modest X-ray count accumulations at individual data points. In this paper we review performance for revealing pattern at modest levels of X-ray count accumulations of a selection of digital filters (moving average smoothers), running median filters, robust locally weighted regression filters and adaptive spline filters. (author)

  2. Ion microprobe mass analysis of plagioclase from 'non-mare' lunar samples

    Science.gov (United States)

    Meyer, C., Jr.; Anderson, D. H.; Bradley, J. G.

    1974-01-01

    The ion microprobe was used to measure the composition and distribution of trace elements in lunar plagioclase, and these analyses are used as criteria in determining the possible origins of some nonmare lunar samples. The Apollo 16 samples with metaclastic texture and high-bulk trace-element contents contain plagioclase clasts with extremely low trace-element contents. These plagioclase inclusions represent unequilibrated relicts of anorthositic, noritic, or troctolitic rocks that have been intermixed as a rock flour into the KREEP-rich matrix of these samples. All of the plagioclase-rich inclusions which were analyzed in the KREEP-rich Apollo 14 breccias were found to be rich in trace elements. This does not seem to be consistent with the interpretation that the Apollo 14 samples represent a pre-Imbrium regolith, because such an ancient regolith should have contained many plagioclase clasts with low trace-element contents more typical of plagioclase from the pre-Imbrium crust. Ion-microprobe analyses for Ba and Sr in large plagioclase phenocrysts in 14310 and 68415 are consistent with the bulk compositions of these rocks and with the known distribution coefficients for these elements. The distribution coefficient for Li (basaltic liquid/plagioclase) was measured to be about 2.

  3. Color electron microprobe cathodoluminescence of Bishunpur meteorite compared with the traditional optical microscopy method

    Directory of Open Access Journals (Sweden)

    Amanda Araujo Tosi

    Full Text Available Abstract Cathodoluminescence (CL imaging is an outstanding method for sub classification of Unequilibrated Ordinary Chondrites (UOC - petrological type 3. CL can be obtained by several electron beam apparatuses. The traditional method uses an electron gun coupled to an optical microscope (OM. Although many scanning electron microscopes (SEM and electron microprobes (EPMA have been equipped with a cathodoluminescence, this technique was not fully explored. Images obtained by the two methods differ due to a different kind of signal acquisition. While in the CL-OM optical photography true colors are obtained, in the CL-EPMA the results are grayscale monochromatic electronic signals. L-RGB filters were used in the CL-EPMA analysis in order to obtain color data. The aim of this work is to compare cathodoluminescence data obtained from both techniques, optical microscope and electron microprobe, on the Bishunpur meteorite classified as LL 3.1 chondrite. The present study allows concluding that 20 KeV and 7 nA is the best analytical condition at EPMA in order to test the equivalence between CL-EPMA and CL-OM colour results. Moreover, the color index revealed to be a method for aiding the study of the thermal metamorphism, but it is not definitive for the meteorite classification.

  4. Development of a scanning proton microprobe - computer-control, elemental mapping and applications

    International Nuclear Information System (INIS)

    Loevestam, Goeran.

    1989-08-01

    A scanning proton microprobe set-up has been developed at the Pelletron accelerator in Lund. A magnetic beam scanning system and a computer-control system for beam scanning and data aquisition is described. The computer system consists of a VMEbus front-end computer and a μVax-II host-computer, interfaced by means of a high-speed data link. The VMEbus computer controls data acquisition, beam charge monitoring and beam scanning while the more sophisticated work of elemental mapping and spectrum evaluations is left to the μVax-II. The calibration of the set-up is described as well as several applications. Elemental micro patterns in tree rings and bark has been investigated by means of elemental mapping and quantitative analysis. Large variations of elemental concentrations have been found for several elements within a single tree ring. An external beam set-up has been developed in addition to the proton microprobe set-up. The external beam has been used for the analysis of antique papyrus documents. Using a scanning sample procedure and particle induced X-ray emission (PIXE) analysis, damaged and missing characters of the text could be made visible by means of multivariate statistical data evaluation and elemental mapping. Also aspects of elemental mapping by means of scanning μPIXE analysis are discussed. Spectrum background, target thickness variations and pile-up are shown to influence the structure of elemental maps considerably. In addition, a semi-quantification procedure has been developed. (author)

  5. Study of the toughening mechanisms in bone and biomimetic hydroxyapatite materials using Raman microprobe spectroscopy.

    Science.gov (United States)

    Pezzotti, Giuseppe; Sakakura, Seiji

    2003-05-01

    A Raman microprobe spectroscopy characterization of microscopic fracture mechanisms is presented for a natural hydroxyapatite material (cortical bovine femur) and two synthetic hydroxyapatite-based materials with biomimetic structures-a hydroxyapatite skeleton interpenetrated with a metallic (silver) or a polymeric (nylon-6) phase. In both the natural and synthetic materials, a conspicuous amount of toughening arose from a microscopic crack-bridging mechanism operated by elasto-plastic stretching of unbroken second-phase ligaments along the crack wake. This mechanism led to a rising R-curve behavior. An additional micromechanism, responsible for stress relaxation at the crack tip, was recognized in the natural bone material and was partly mimicked in the hydroxyapatite/silver composite. This crack-tip mechanism conspicuously enhanced the cortical bone material resistance to fracture initiation. A piezo-spectroscopic technique, based on a microprobe measurement of 980 cm(-1) Raman line of hydroxyapatite, enabled us to quantitatively assess in situ the microscopic stress fields developed during fracture both at the crack tip and along the crack wake. Using the Raman piezo-spectroscopy technique, toughening mechanisms were assessed quantitatively and rationally related to the macroscopic fracture characteristics of hydroxyapatite-based materials. Copyright 2003 Wiley Periodicals, Inc.

  6. Optical system optimization of the microprobe beamline of the Ion Implantation Laboratory (IF-UFRGS), Brazil

    International Nuclear Information System (INIS)

    Bauer, Deiverti de Vila

    2015-01-01

    The aim of the present work is to optimize the microprobe beamline of the Ion Implantation Laboratory (IF-UFRGS). In short, an ion microprobe consists of charged particles focused to the dimensions of a few micrometers. The focusing system is made of two slits for demagnification, a set of magnetic lenses with scanning capability and a reaction chamber. By changing the parameters related to this system, one can optimize the features of the beam. To that end, samples of poly(tereftalate etylene) were irradiated with 2.2 MeV H+ ions and etched, yielding 2D microstructures with high aspect ratio. The analysis of the structures with Scanning Electron Microscopy proved to be an important tool in order to establish a correlation between the size of the microstructures and the parameters of the focusing system. In this work, the causes leading to a beam enlargement are discussed, as well as the aberrations which affect the system. Finally, the advantages of using ions for lithography purposes is pointed out. (author)

  7. Determination of trace element mineral/liquid partition coefficients in melilite and diopside by ion and electron microprobe techniques

    Science.gov (United States)

    Kuehner, S. M.; Laughlin, J. R.; Grossman, L.; Johnson, M. L.; Burnett, D. S.

    1989-01-01

    The applicability of ion microprobe (IMP) for quantitative analysis of minor elements (Sr, Y, Zr, La, Sm, and Yb) in the major phases present in natural Ca-, Al-rich inclusions (CAIs) was investigated by comparing IMP results with those of an electron microprobe (EMP). Results on three trace-element-doped glasses indicated that it is not possible to obtain precise quantitative analysis by using IMP if there are large differences in SiO2 content between the standards used to derive the ion yields and the unknowns.

  8. Improved 206Pb/238U microprobe geochronology by the monitoring of a trace-element-related matrix effect; SHRIMP, ID-TIMS, ELA-ICP-MS and oxygen isotope documentation for a series of zircon standards

    Science.gov (United States)

    Black, L.P.; Kamo, S.L.; Allen, C.M.; Davis, D.W.; Aleinikoff, J.N.; Valley, J.W.; Mundil, R.; Campbell, I.H.; Korsch, R.J.; Williams, I.S.; Foudoulis, C.

    2004-01-01

    Precise isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) documentation is given for two new Palaeozoic zircon standards (TEMORA 2 and R33). These data, in combination with results for previously documented standards (AS3, SL13, QGNG and TEMORA 1), provide the basis for a detailed investigation of inconsistencies in 206Pb/238U ages measured by microprobe. Although these ages are normally consistent between any two standards, their relative age offsets are often different from those established by ID-TIMS. This is true for both sensitive high-resolution ion-microprobe (SHRIMP) and excimer laser ablation-inductively coupled plasma-mass spectrometry (ELA-ICP-MS) dating, although the age offsets are in the opposite sense for the two techniques. Various factors have been investigated for possible correlations with age bias, in an attempt to resolve why the accuracy of the method is worse than the indicated precision. Crystallographic orientation, position on the grain-mount and oxygen isotopic composition are unrelated to the bias. There are, however, striking correlations between the 206Pb/238U age offsets and P, Sm and, most particularly, Nd abundances in the zircons. Although these are not believed to be the primary cause of this apparent matrix effect, they indicate that ionisation of 206Pb/238U is influenced, at least in part, by a combination of trace elements. Nd is sufficiently representative of the controlling trace elements that it provides a quantitative means of correcting for the microprobe age bias. This approach has the potential to reduce age biases associated with different techniques, different instrumentation and different standards within and between laboratories. Crown Copyright ?? 2004 Published by Elsevier B.V. All rights reserved.

  9. Report of the review of WWER-1000 safety issues resolution at Temelin nuclear power plant, Temelin, Czech Republic 11 to 15 March 1996

    International Nuclear Information System (INIS)

    Almeida, C.; Hoehn, J.; Seiberling, R.; Chambon, J.L.; Fil, N.S.; Munoz, A.; Roennberg, G.; Wenk, W.

    1996-01-01

    At the request of the Government of the Czech Republic, the IAEA conducted, in the period of 11-15 March 1996, a mission to review the resolution of WWER-1000 safety issues at Temelin NPP. These safety issues have been identified for WWER-1000 model 320 reactors and ranked according to their importance to safety in the frameworks of the IAEA Extrabudgetary Programme on Safety of WWER and RBMK Nuclear Power Plants. The Temelin NPP is a WWER-1000 and was originally designed according to standards of the former Soviet Union. After a series of reviews in the 1980s, a decision was taken by the Temelin NPP management to upgrade the design of Temelin, including the supply of fuel and instrumentation and control by a western company. The objective of the mission was to review the response of Temelin to the safety issues identified by the IAEA. The mission assessed the current Temelin design, including proposed modifications and plans for operation at Temelin, in the light of the IAEA recommendations for each relevant issue. The present report contains the mission's general conclusions and recommendations and an overview of the review performed in each topical area. The attachment contains a brief summary of the discussions on each individual safety issue and associated conclusions and recommendations. 3 refs

  10. Metabolomics by Proton High-Resolution Magic-Angle-Spinning Nuclear Magnetic Resonance of Tomato Plants Treated with Two Secondary Metabolites Isolated from Trichoderma.

    Science.gov (United States)

    Mazzei, Pierluigi; Vinale, Francesco; Woo, Sheridan Lois; Pascale, Alberto; Lorito, Matteo; Piccolo, Alessandro

    2016-05-11

    Trichoderma fungi release 6-pentyl-2H-pyran-2-one (1) and harzianic acid (2) secondary metabolites to improve plant growth and health protection. We isolated metabolites 1 and 2 from Trichoderma strains, whose different concentrations were used to treat seeds of Solanum lycopersicum. The metabolic profile in the resulting 15 day old tomato leaves was studied by high-resolution magic-angle-spinning nuclear magnetic resonance (HRMAS NMR) spectroscopy directly on the whole samples without any preliminary extraction. Principal component analysis (PCA) of HRMAS NMR showed significantly enhanced acetylcholine and γ-aminobutyric acid (GABA) content accompanied by variable amount of amino acids in samples treated with both Trichoderma secondary metabolites. Seed germination rates, seedling fresh weight, and the metabolome of tomato leaves were also dependent upon doses of metabolites 1 and 2 treatments. HRMAS NMR spectroscopy was proven to represent a rapid and reliable technique for evaluating specific changes in the metabolome of plant leaves and calibrating the best concentration of bioactive compounds required to stimulate plant growth.

  11. Nuclear

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    The first text deals with a new circular concerning the collect of the medicine radioactive wastes, containing radium. This campaign wants to incite people to let go their radioactive wastes (needles, tubes) in order to suppress any danger. The second text presents a decree of the 31 december 1999, relative to the limitations of noise and external risks resulting from the nuclear facilities exploitation: noise, atmospheric pollution, water pollution, wastes management and fire prevention. (A.L.B.)

  12. Resolution 737/991 Nuclear Energy: approval of Action Plan for biennium 1991-1992 about cooperation for peaceful uses between Argentina and Uruguay

    International Nuclear Information System (INIS)

    1991-01-01

    The plan of action approved for the biennium 1991-1992 to implement the Agreement of Cooperation in the field of the peaceful uses of the Nuclear Energy between the Republic of Argentina and the Eastern Republic of Uruguay in the following areas: nuclear fuels, destructive and non-destructive, thermohydraulics, calculation, tests, and physics of reactors and neutrons, control systems, nuclear and electronic instrumentation, radiological protection and nuclear security, dosimetry, radiological emergency, calibrations, management of nuclear power generation, costs, nuclear fuel cycle, medical and veterinary applications, nuclear analytical techniques and environmental studies [es

  13. Microprobe analyses of uranium and thorium in uraninite from the Witwatersrand, South Africa, and Blind River, Ontario, Canada

    International Nuclear Information System (INIS)

    Grandstaff, D.E.

    1981-01-01

    Microprobe analyses of uranium and thorium in uraninite grains from the Witwatersrand, South Africa, and Blind River, Ontario, reveal that although individual grains are fairly homogeneous, the assemblage of grains is quite heterogeneous. This heterogeneity appears to favor genetic concepts advocating a detrital, placer origin for the uraninite

  14. Identification of relevant conditions and experiments for fuel-coolant interactions in nuclear power plants - SERENA Co-ordinated Programme (Steam Explosion Resolution for Nuclear Applications) Phase 1, Task 1 - Final report

    International Nuclear Information System (INIS)

    Magallon, D.; Scott de Martinville, E.; Chaumont, B.; Filippi, M.; Meignen, R.; Berthoud, G.; Ratel, G.; Melikhov, O.I.; Melikhov, V.I.; Jacobs, H.; Buerger, Manfred; Buck, Michael; Moriyama, K.; Nakamura, H.; Hirano, M.; Muramatsu, K.; Ishikawa, J.; Song, Jinho; Bang, Kwanghyun; Suh, Namduk; Sairanen, Risto; Lindholm, Ilona

    2004-01-01

    SERENA (Steam Explosion Resolution for Nuclear Applications) is an international OECD programme for the resolution of FCI remaining issues. The programme has origin the concerns expressed by the Senior Group Experts on Nuclear Safety Research and Programme (SESAR/FAP) about de-emphasis of FCI research all over the world, while uncertainties still exist on some aspects of FCI. After an evaluation of remaining needs by FCI experts in a meeting October 2000, a proposal was matured during 2001 following CSNI recommendations that existing knowledge should be carefully assessed before carrying out new experiments, and reactor application should be the focus of any new action. The work programme was approved by CSNI December 2001. The programme started January 2002. The overall objective of SERENA is to obtain convergence on the understanding of FCI processes and energetics, as well as on method(s) for reliable estimate of the magnitude of loadings for realistic reactor conditions, in order to bring understanding and predictability of FCI energetics to desirable levels for risk management. The work is performed in two phases: - Phase 1 analyses and evaluates knowledge and data on FCI by using available tools with the aim to identify areas where large uncertainties/ discrepancies still subsist and are important for predicting loads in reactors with a sufficient level of confidence, and work to be done, if any, to reduce these uncertainties/discrepancies. - Phase 2 will implement analytical and experimental actions to resolve these uncertainties/ discrepancies, if required. The objective of Phase 1 is reached through comparative calculations by available tools of existing experiments and reactor cases. It is divided into five tasks: 1. Identification of relevant conditions for FCI in reactor, 2. Comparison of various approaches for calculating jet break-up and pre-mixing, 3. Comparison of various approaches for calculating the explosion phase, 4. Reactor applications, 5

  15. Microprobe monazite constraints for and early (ca. 790 Ma) Braziliano orogeny: The Embu Terrane, southeastern Brazil

    International Nuclear Information System (INIS)

    Vlach, Silvio R.F

    2001-01-01

    The evolution of the Mantiqueira Orogenetic System, Southeastern Brazil, comprises discrete episodes of tectonic collage and docking of remnants of Rodinia break-up in the borders of the Sao Francisco Craton. This system is related to the closure of the Adamastor ocean and assemblage of the western Gondwana super-continent during Neoproterozoic times (ca. 610-530 Ma, Brito Neves et al., 1999; Campos Neto, 2000). This report presents monazite microprobe dating results for metassediments from the Embu Complex, an important lithological unit from the Ribeira Belt, currently included in the Juiz de Fora terrane, a unit added to the Sao Francisco Craton at ca. 600-580 Ma. (Campos Neto, 2000). The age results unravel a main metamorphic episode and related orogeny at ca. 790 Ma and bring new insights concerning the agglutination of Gondwana in this region during the Neoproterozoic (au)

  16. The non-destructive analysis of fluid inclusions in minerals using the proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C.G.; Van Achterbergy, E. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Heinrich, C.A. [ETH Zentrum, Zurich, (Switzerland). Department Erdwissenschaften; Mernagh, T.P. [Max-Planck-Institut fuer Chemie (Otto-Hahn-Institut), Mainz (Germany); Zaw, K. [Tasmania Univ., Sandy Bay, TAS (Australia)

    1996-12-31

    The study of ore forming fluids trapped as fluid inclusions in minerals is the key to understanding fluid flow paths at the time of ore formation and to predicting the location of ore bodies within large-scale magmatic hydrothermal systems. The large penetration depths and the predictable nature of MeV proton trajectories and X-ray absorption enables reliable modelling of PIXE yields and the development of standardless quantitative analytical methods. This permits quantitative microanalysis of minerals at ppm levels, and more recently has enabled the development of methods for quantitative trace-element imaging and the quantitative, non-destructive analysis of individual fluid inclusions. This paper reports on recent developments in Proton Microprobe techniques with special emphasis on ore systems and fluid inclusion analysis. 6 refs., 2 figs.

  17. Trace element partitioning between aqueous fluids and silicate melts measured with a proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Adam, J.; Green, T.H. [Macquarie Univ., North Ryde, NSW (Australia). School of Earth Sciences; Sie, S.H. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1996-12-31

    A series of experiments were performed to examine the capacity of H{sub 2}O-fluids to concentrate and transport incompatible elements through peridotitic mantle and metamorphosed (eclogitic) ocean crust. Two naturally occurring rock compositions, trondhjemitic and basanitic, were used in experiments. The proton microprobe was used to determine the trace element concentrations in the solutes from H{sub 2}O-fluids equilibrated at 900-1100 degree C, 2.0 GPa with water saturated melts of trondhjemitic and basanitic compositions. Partitioning data for H{sub 2}O-fluids and silicate melts show that H{sub 2}O-fluids equilibrated with mantle peridotites will not be strongly enriched in trace elements relative to their wallrocks, and thus they melts do not strongly concentrate alkaline earths Th and U, relative to high-field strength elements. 3 refs., 1 tab., 2 figs.

  18. The non-destructive analysis of fluid inclusions in minerals using the proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C G; Van Achterbergy, E [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Heinrich, C A [ETH Zentrum, Zurich, (Switzerland). Department Erdwissenschaften; Mernagh, T P [Max-Planck-Institut fuer Chemie (Otto-Hahn-Institut), Mainz (Germany); Zaw, K [Tasmania Univ., Sandy Bay, TAS (Australia)

    1997-12-31

    The study of ore forming fluids trapped as fluid inclusions in minerals is the key to understanding fluid flow paths at the time of ore formation and to predicting the location of ore bodies within large-scale magmatic hydrothermal systems. The large penetration depths and the predictable nature of MeV proton trajectories and X-ray absorption enables reliable modelling of PIXE yields and the development of standardless quantitative analytical methods. This permits quantitative microanalysis of minerals at ppm levels, and more recently has enabled the development of methods for quantitative trace-element imaging and the quantitative, non-destructive analysis of individual fluid inclusions. This paper reports on recent developments in Proton Microprobe techniques with special emphasis on ore systems and fluid inclusion analysis. 6 refs., 2 figs.

  19. Electron microprobe investigations of ore minerals of the Altenberg tin deposit (Erzgebirge, GDR). 3

    International Nuclear Information System (INIS)

    Foerster, H.J.; Hunger, H.J.; Grimm, L.

    1987-01-01

    Members of the scheelite-powellite solid solution series filling thin fractures or mantling wolframite were found in association with fluorite within a small polymineralic quartz vein traversing a topaz-protolithionite-quartz greisen. The composition of the mixed-crystal series determined by means of an automated ARL SEMQ energy-dispersive electron microprobe is characterized by a great variability and heterogeneity which has not previously been reported from any specimen nor from this special mode of occurrence yet. With an amount of powellite component between 3.2 and 58 mole percent, the molybdoscheelites from Altenberg show the today known extent of complete miscibility in the natural scheelite-powellite series. Final remarks deal with the possibilities of using the mineral series, together with some other tungsten minerals, as an indicator of the physicochemical conditions of ore formation. (author)

  20. A new method for true quantitative elemental imaging using PIXE and the proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C G [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Jamieson, D N [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Churms, C L; Pilcher, J V [National Accelerator Centre, Faure (South Africa)

    1994-12-31

    Traditional methods for X-ray imaging using PIXE and the Proton Microprobe have used a simple gate set on an X-ray peak in a spectrum from a Si(Li) detector to provide an image of the distribution of an element. This method can produce artefacts in images, due to overlapping X-ray lines from interfering elements, charge collection tails on peaks, background variation, Si escape peaks and pileup, all of which can render images misleading or qualitative at best. To address this problem, a matrix transform method has been developed at the CSIRO which not only eliminates most artefacts, but can be implemented on-line. The method has been applied to study trace gold distribution in a complex gold bearing ore from Fiji , and more recently has been installed for direct on-line elemental imaging at the NAC in South Africa. 4 refs., 2 figs.

  1. Laser ablation microprobe inductively coupled plasma mass spectrometry study on diffusion of uranium into cement materials

    International Nuclear Information System (INIS)

    Sugiyama, D.; Chida, T.; Cowper, M.

    2008-01-01

    The diffusion of uranium (U(VI)) in solid cement monoliths of ordinary portland cement (OPC) and low-heat portland cement containing 30 wt.% fly ash (FAC) was measured by an in-diffusion technique. Detailed sharp depth profiles of uranium in the solid cement matrices were successively and quantitatively measured using laser ablation microprobe inductively coupled plasma mass spectrometry (LAMP-ICP-MS), and the apparent (D a ) and effective (D e ) diffusion coefficient of uranium in cement matrix were calculated as: D a =∝ 4 x 10 -16 m 2 s -1 and D e =∝ 3 x 10 -11 m 2 s -1 for OPC, and D a =∝ 2 x 10 -17 m 2 s -1 and D e =∝ 6 x 10 -13 m 2 s -1 for FAC. (orig.)

  2. A new method for true quantitative elemental imaging using PIXE and the proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C.G. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Churms, C.L.; Pilcher, J.V. [National Accelerator Centre, Faure (South Africa)

    1993-12-31

    Traditional methods for X-ray imaging using PIXE and the Proton Microprobe have used a simple gate set on an X-ray peak in a spectrum from a Si(Li) detector to provide an image of the distribution of an element. This method can produce artefacts in images, due to overlapping X-ray lines from interfering elements, charge collection tails on peaks, background variation, Si escape peaks and pileup, all of which can render images misleading or qualitative at best. To address this problem, a matrix transform method has been developed at the CSIRO which not only eliminates most artefacts, but can be implemented on-line. The method has been applied to study trace gold distribution in a complex gold bearing ore from Fiji , and more recently has been installed for direct on-line elemental imaging at the NAC in South Africa. 4 refs., 2 figs.

  3. Development of a shielded ion microprobe analyzer (SIMA) and its application to fast reactor fuel elements

    International Nuclear Information System (INIS)

    Yuji, E.; Junji, K.; Sadamu, Y.; Toshiyuki, I.

    1983-01-01

    A shielded ion microprobe analyzer for elemental and isotopic analyses of irradiated fast reactor fuel and fuel component has been developed and installed in an alpha-gamma hot cell. Radiation shielding of the equipment ensures the radiation dose of -7 C/kg) for 5 Ci (1.85 x 10 11 Bq) of a 60 Co source. Hot samples can be automatically transferred from the cell to the sample chamber of the analyzer. Contamination inside the equipment through sputtering of the radioactive materials can be reduced with a special device. Distribution and migration of fission products, such as 137 Cs, 138 Ba, and 90 Sr, and of fissile materials, such as 235 U and 239 Pu in irradiated mixed-oxide fuel, and isotopic ratios of the elements can be obtained very precisely and quickly

  4. Development of a shielded ion microprobe analyzer (SIMA) and its application to fast reactor fuel elements

    International Nuclear Information System (INIS)

    Enokido, Y.; Itaki, T.; Komatsu, J.; Yamanouchi, S.

    1983-01-01

    A shielded ion microprobe analyzer for elemental and isotopic analyses of irradiated fast reactor fuel and fuel component has been developed and installed in an alpha-gamma hot cell. Radiation shielding of the equipment ensures the radiation dose of -7 C/kg) for 5 Ci (1.85 X 10 11 Bq) of a 60 Co source. Hot samples can be automatically transferred from the cell to the sample chamber of the analyzer. Contamination inside the equipment through sputtering of the radioactive materials can be reduced with a special device. Distribution and migration of fission products, such as 137 Cs, 138 Ba, and 90 Sr, and of fissile materials, such as 235 U and 239 Pu in irradiated mixed-oxide fuel, and isotopic ratios of the elements can be obtained very precisely and quickly

  5. Microprobe and SEM Analysis of a Meteorite from the Campo del Cielo Fall

    International Nuclear Information System (INIS)

    Cabanillas, E. D.; Palacios, T. A.

    2003-01-01

    Full Text: Meteorites are unique pieces in nature having not only the enigmatic connotations of the unknown but also are the easier obtained samples of the exterior universe. Furthermore they are the unique alloys that suffered modifications done during enormous periods of time in space and in land The Campo del Cielo fall, occurred more than 5000 years ago, gave hundredths of pieces some of them well studied. We have studied one of the minor pieces from the fall and with microprobe and scanning electronic microscopy analysis we determined the composition of Schreibersite and Rhabdite phosphides of iron and nickel. This study was performed to establish relationships between the duration of alloys and the design of disposal of high level and long lived radioactive waste

  6. Physical aspects of quantitative particles analysis by X-ray fluorescence and electron microprobe techniques

    International Nuclear Information System (INIS)

    Markowicz, A.

    1986-01-01

    The aim of this work is to present both physical fundamentals and recent advances in quantitative particles analysis by X-ray fluorescence (XRF) and electron microprobe (EPXMA) techniques. A method of correction for the particle-size effect in XRF analysis is described and theoretically evaluated. New atomic number- and absorption correction procedures in EPXMA of individual particles are proposed. The applicability of these two correction methods is evaluated for a wide range of elemental composition, X-ray energy and sample thickness. Also, a theoretical model for composition and thickness dependence of Bremsstrahlung background generated in multielement bulk specimens as well as thin films and particles are presented and experimantally evaluated. Finally, the limitations and further possible improvements in quantitative particles analysis by XFR and EPXMA are discussed. 109 refs. (author)

  7. Trace element partitioning between aqueous fluids and silicate melts measured with a proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Adam, J; Green, T H [Macquarie Univ., North Ryde, NSW (Australia). School of Earth Sciences; Sie, S H [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1997-12-31

    A series of experiments were performed to examine the capacity of H{sub 2}O-fluids to concentrate and transport incompatible elements through peridotitic mantle and metamorphosed (eclogitic) ocean crust. Two naturally occurring rock compositions, trondhjemitic and basanitic, were used in experiments. The proton microprobe was used to determine the trace element concentrations in the solutes from H{sub 2}O-fluids equilibrated at 900-1100 degree C, 2.0 GPa with water saturated melts of trondhjemitic and basanitic compositions. Partitioning data for H{sub 2}O-fluids and silicate melts show that H{sub 2}O-fluids equilibrated with mantle peridotites will not be strongly enriched in trace elements relative to their wallrocks, and thus they melts do not strongly concentrate alkaline earths Th and U, relative to high-field strength elements. 3 refs., 1 tab., 2 figs.

  8. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A A; Jamieson, D N; Prawer, S; Allen, M G [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  9. Hg diffusion in books of XVIII and XIX centuries by synchrotron microprobe

    International Nuclear Information System (INIS)

    Pessanha, S.; Carvalho, M.L.; Manso, M.; Guilherme, A.; Marques, A.F.; Perez, C.A.

    2009-01-01

    The pigment vermilion (HgS) was used to color the fore edge, tail and head of books. Dissemination and quantification of Hg present in the ink used to color books from XVIII and XIX centuries are reported. Mercury is a very toxic element for the human body, therefore it is extremely important to know whether Hg tends to disseminate throughout the paper or stays confined to the borders of the books with less danger for readers. Synchrotron X-ray microprobe was used to evaluate Hg dissemination from the border to the centre of the paper sheet. The diffusion pattern of Hg was compared with the results obtained by a portable X-ray fluorescence spectrometer and mean quantitative calculations were obtained by a stationary X-ray fluorescence system with triaxial geometry. The results showed high concentrations of Hg in the external regions, but no diffusion was observed for the inner parts of the paper.

  10. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    International Nuclear Information System (INIS)

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the element Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  11. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    International Nuclear Information System (INIS)

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the elements Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  12. Study of ancient Islamic gilded pieces combining PIXE-RBS on external microprobe with sem images

    International Nuclear Information System (INIS)

    Ynsa, M.D.; Gutierrez, P.C.; Enguita, O.; Chamon, J.; Pardo, A.I.; Arroyo, M.; Barrio, J.; Gomez-Morilla, I.; Ferretti, M.; Climent-Font, A.

    2008-01-01

    Numerous metallic objects with very aesthetic and technological qualities have been recovered by archaeological excavations. Adequate processes of restoration and conservation treatments require the accurate determination of the elemental composition and distribution within the objects, as well as the identification of the nature and distribution of the corrosion products. Ideally the identification method should cause no alteration in the sample. In this work, different archaeological pieces with a gilded look have been characterized using simultaneously PIXE and RBS at the CMAM external microprobe in order to study the gilding metalworking done in the Iberian Peninsula during the Middle Ages. The gold layer thickness and its elemental concentrations of Ag, Au and Hg were determined by both techniques and compared with the scanning electron microscopy images obtained for some fragments of pieces. (orig.)

  13. Microprobe study of fission product behavior in high-burnup HTR fuels

    International Nuclear Information System (INIS)

    Kleykamp, H.

    Electron microprobe analysis of irradiated coated particles with high burnup (greater than 50 percent fima) gives detailed information on the chemical state and the transport behavior of the fission products in UO 2 and UC 2 kernels and in the coatings. In oxide fuel kernels, metallic inclusions and ceramic precipitations are observed. The solubility behavior of the fission products in the fuel matrix has been investigated. Fission product inclusions could not be detected in carbide fuel kernels; post irradiation annealed UC 2 kernels, however, give information on the element combinations of some fission product phases. Corresponding to the chemical state in the kernel, Cs, Sr, Ba, Pd, Te and the rare earths are released easily and diffuse through the entire pyrocarbon coating. These fission products can be retained by a silicon carbide layer. The initial stage of a corrosive attack of the SiC coating by the fission products is evidenced

  14. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A.; Jamieson, D. N.; Prawer, S.; Allen, M.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  15. Measurements of impurity migration in graphite at high temperatures using a proton microprobe

    International Nuclear Information System (INIS)

    Shroy, R.E.; Soo, P.; Sastre, C.A.; Schweiter, D.G.; Kraner, H.W.; Jones, K.W.

    1978-01-01

    The migration of fission products and other impurities through the graphite core of a High Temperature Gas Cooled Reactor is of prime importance in studies of reactor safety. Work in this area is being carried out in which graphite specimens are heated to temperatures up to 3800 0 C to induce migration of trace elements whose local concentrations are then measured with a proton microprobe. This instrument is a powerful device for such work because of its ability to determine concentrations at a part per million (ppm) level in a circular area as small as 10 μm while operating in an air environment. Studies show that Si, Ca, Cl, and Fe impurities in graphite migrate from hotter to cooler regions. Also Si, S, Cl, Ca, Fe, Mn, and Cr are observed to escape from the graphite and be deposited on cooler surfaces

  16. Present status of research and development on X-ray microprobe

    International Nuclear Information System (INIS)

    Koike, Masaki; Suzuki, I.H.

    1991-01-01

    X-ray beam micro-analysis has advanced rapidly in these years in conjunction with the development of powerful X-ray sources. Among a variety of methods being attempted, the method using a collimated narrow beam has been important because of high brightness, and of usability in both regions of soft and hard X-rays. In the soft X-ray region, the focused beam is formed by a fresnel zone plate or a Schwaltzschild mirror assembly, and can be used for scanning transmission microscope or scanning photoelectron microscope. In the hard X-ray region, the beam is formed by grazing incidence mirrors, and can be used for X-ray fluorescence micro-analysis for obtaining elemental mapping. In this report, the recent progress on the soft X-ray scanning microscopy and the X-ray microprobe has been surveyed, together with the improvement on the related optical elements. (author) 84 refs

  17. Fabrication of wear-resistant silicon microprobe tips for high-speed surface roughness scanning devices

    Science.gov (United States)

    Wasisto, Hutomo Suryo; Yu, Feng; Doering, Lutz; Völlmeke, Stefan; Brand, Uwe; Bakin, Andrey; Waag, Andreas; Peiner, Erwin

    2015-05-01

    Silicon microprobe tips are fabricated and integrated with piezoresistive cantilever sensors for high-speed surface roughness scanning systems. The fabrication steps of the high-aspect-ratio silicon microprobe tips were started with photolithography and wet etching of potassium hydroxide (KOH) resulting in crystal-dependent micropyramids. Subsequently, thin conformal wear-resistant layer coating of aluminum oxide (Al2O3) was demonstrated on the backside of the piezoresistive cantilever free end using atomic layer deposition (ALD) method in a binary reaction sequence with a low thermal process and precursors of trimethyl aluminum and water. The deposited Al2O3 layer had a thickness of 14 nm. The captured atomic force microscopy (AFM) image exhibits a root mean square deviation of 0.65 nm confirming the deposited Al2O3 surface quality. Furthermore, vacuum-evaporated 30-nm/200-nm-thick Au/Cr layers were patterned by lift-off and served as an etch mask for Al2O3 wet etching and in ICP cryogenic dry etching. By using SF6/O2 plasma during inductively coupled plasma (ICP) cryogenic dry etching, micropillar tips were obtained. From the preliminary friction and wear data, the developed silicon cantilever sensor has been successfully used in 100 fast measurements of 5- mm-long standard artifact surface with a speed of 15 mm/s and forces of 60-100 μN. Moreover, the results yielded by the fabricated silicon cantilever sensor are in very good agreement with those of calibrated profilometer. These tactile sensors are targeted for use in high-aspect-ratio microform metrology.

  18. Trans-Regional technologies and the Lapita problem: characterisation of volcanic glass inclusions by electron microprobe

    International Nuclear Information System (INIS)

    Grave, P.; Nockolds, C.; White, P.

    1997-01-01

    Full text: Analysis of pre-modern pottery of the Pacific has long attempted to formulate measures independent of style for constructing archaeologically meaningful groups. However, the variable character of fabrics and the longevity of production (Lapita and post-Lapita wares from 3000 years ago to the present) have tended to obscure differences due to changes in production practices and resources through time and differences relating to the exchange of ceramics between islands or regions. In this poster we outline a preliminary study that employs an economical and robust technique to distinguish both within- and between-region groups. This is achieved with electron microprobe analysis of small volcanic glass fragments present in wares tempered with volcanic sands, and interpretation based on Principal Components Analysis. The method builds on the chemical groupings for glass from different volcanic complexes in the Pacific established through high energy ion beam (PIXE-PIGME) analysis. The purpose of this study is to characterise a selection of samples of pottery from the Duke of York's peninsula using electron microprobe analysis of very small glass fragments in the sections that ranged in size from around 0.05 mm to 1 mm.. The study involved the identification and elemental characterisation of individual fragments of glass in a section. Principal Component Analysis was used to identify structure latent in the dataset. The results of the study show that clear characterisation is possible to enable the wider application of the technique to Lapita and post Lapita ceramics produced originating in volcanic areas of the Pacific

  19. Fabrication of an 8:1 ellipsoidal mirror for a synchrotron x-ray microprobe

    International Nuclear Information System (INIS)

    Jones, K.W.; Takacs, P.Z.; Hastings, J.B.; Casstevens, J.M.; Pionke, C.D.

    1987-01-01

    The fabrication of an 8:1 demagnifying ellipsoidal mirror to be used for an x-ray microprobe at the National Synchrotron Light Source X-26 beam port is described. The design aim was to produce a mirror that could be used over the photon energy range from about 3 to 17 keV. The 300-mm long mirror was required to operate at a grazing angle of 5 mr. The semimajor axis was 4500 mm and the semiminor axis 14.142 mm. Surface roughness of 1 nm or less and slope errors of 1 arc second parallel to the long axis and 200 arc seconds parallel to the short direction were specified. Production of the first electroless nickel-coated aluminum mirror using a diamond-turning technique has been completed. The mirror meets the 1 arc sec surface figure specification except for areas near the ends of the mirror. The reasons for these deviations arise from subtle details of the diamond-turning process which have not been fully incorporated in to the computer program that controls the diamond-turning machines. Further work in computer correction of repeatable errors of the diamond-turning machine can eliminate the waviness at the ends of the mirror. The diamond-turned mirror surface was not fully polished under this effort and therefore does not meet the roughness specification; however, surface smoothness of a fully polished cylindrical mirror manufactured using the same techniques does not meet the specification. It can be concluded that it is now technically feasible to meet the required specifications for the mirror and that the x-ray microprobe based on its use can be achieved

  20. 10 CFR 74.57 - Alarm resolution.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Alarm resolution. 74.57 Section 74.57 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) MATERIAL CONTROL AND ACCOUNTING OF SPECIAL NUCLEAR MATERIAL Formula... unresolved beyond the time period specified for its resolution in the licensee's fundamental nuclear material...

  1. MO-G-17A-04: Internal Dosimetric Calculations for Pediatric Nuclear Imaging Applications, Using Monte Carlo Simulations and High-Resolution Pediatric Computational Models

    Energy Technology Data Exchange (ETDEWEB)

    Papadimitroulas, P; Kagadis, GC [University of Patras, Rion, Ahaia (Greece); Loudos, G [Technical Educational Institute of Athens, Aigaleo, Attiki (Greece)

    2014-06-15

    Purpose: Our purpose is to evaluate the administered absorbed dose in pediatric, nuclear imaging studies. Monte Carlo simulations with the incorporation of pediatric computational models can serve as reference for the accurate determination of absorbed dose. The procedure of the calculated dosimetric factors is described, while a dataset of reference doses is created. Methods: Realistic simulations were executed using the GATE toolkit and a series of pediatric computational models, developed by the “IT'IS Foundation”. The series of the phantoms used in our work includes 6 models in the range of 5–14 years old (3 boys and 3 girls). Pre-processing techniques were applied to the images, to incorporate the phantoms in GATE simulations. The resolution of the phantoms was set to 2 mm3. The most important organ densities were simulated according to the GATE “Materials Database”. Several used radiopharmaceuticals in SPECT and PET applications are being tested, following the EANM pediatric dosage protocol. The biodistributions of the several isotopes used as activity maps in the simulations, were derived by the literature. Results: Initial results of absorbed dose per organ (mGy) are presented in a 5 years old girl from the whole body exposure to 99mTc - SestaMIBI, 30 minutes after administration. Heart, kidney, liver, ovary, pancreas and brain are the most critical organs, in which the S-factors are calculated. The statistical uncertainty in the simulation procedure was kept lower than 5%. The Sfactors for each target organ are calculated in Gy/(MBq*sec) with highest dose being absorbed in kidneys and pancreas (9.29*10{sup 10} and 0.15*10{sup 10} respectively). Conclusion: An approach for the accurate dosimetry on pediatric models is presented, creating a reference dosage dataset for several radionuclides in children computational models with the advantages of MC techniques. Our study is ongoing, extending our investigation to other reference models and

  2. MO-G-17A-04: Internal Dosimetric Calculations for Pediatric Nuclear Imaging Applications, Using Monte Carlo Simulations and High-Resolution Pediatric Computational Models

    International Nuclear Information System (INIS)

    Papadimitroulas, P; Kagadis, GC; Loudos, G

    2014-01-01

    Purpose: Our purpose is to evaluate the administered absorbed dose in pediatric, nuclear imaging studies. Monte Carlo simulations with the incorporation of pediatric computational models can serve as reference for the accurate determination of absorbed dose. The procedure of the calculated dosimetric factors is described, while a dataset of reference doses is created. Methods: Realistic simulations were executed using the GATE toolkit and a series of pediatric computational models, developed by the “IT'IS Foundation”. The series of the phantoms used in our work includes 6 models in the range of 5–14 years old (3 boys and 3 girls). Pre-processing techniques were applied to the images, to incorporate the phantoms in GATE simulations. The resolution of the phantoms was set to 2 mm3. The most important organ densities were simulated according to the GATE “Materials Database”. Several used radiopharmaceuticals in SPECT and PET applications are being tested, following the EANM pediatric dosage protocol. The biodistributions of the several isotopes used as activity maps in the simulations, were derived by the literature. Results: Initial results of absorbed dose per organ (mGy) are presented in a 5 years old girl from the whole body exposure to 99mTc - SestaMIBI, 30 minutes after administration. Heart, kidney, liver, ovary, pancreas and brain are the most critical organs, in which the S-factors are calculated. The statistical uncertainty in the simulation procedure was kept lower than 5%. The Sfactors for each target organ are calculated in Gy/(MBq*sec) with highest dose being absorbed in kidneys and pancreas (9.29*10 10 and 0.15*10 10 respectively). Conclusion: An approach for the accurate dosimetry on pediatric models is presented, creating a reference dosage dataset for several radionuclides in children computational models with the advantages of MC techniques. Our study is ongoing, extending our investigation to other reference models and evaluating the

  3. Local pH Monitoring of Small Cluster of Cells using a Fiber-Optic Dual-Core Micro-Probe.

    Science.gov (United States)

    Chen, Sisi; Yang, Qingbo; Xiao, Hai; Shi, Honglan; Ma, Yinfa

    2017-03-31

    Biological studies of tissues and cells have enabled numerous discoveries, but these studies still bear potential risks of invalidation because of cell heterogeneity. Through high-accuracy techniques, recent studies have demonstrated that discrepancies do exist between the results from low-number-cell studies and cell-population-based results. Thus the urgent need to re-evaluate key principles on limited number of cells has been provoked. In this study, a novel designed dual-core fiber-optic pH micro-probe was fabricated and demonstrated for niche environment pH sensing with high spatial resolution. An organic-modified silicate (OrMoSils) sol-gel thin layer was functionalized by entrapping a pH indicator, 2', 7'-Bis (2-carbonylethyl)-5(6)-carboxyfluorescein (BCECF), on a ~70 μm sized probe tip. Good linear correlation between fluorescence ratio of I 560 nm /I 640 nm and intercellular pH values was obtained within a biological-relevant pH range from 6.20 to 7.92 (R 2 = 0.9834), and with a pH resolution of 0.035 ± 0.005 pH units. The probe's horizontal spatial resolution was demonstrated to be less than 2mm. Moreover, the probe was evaluated by measuring the localized extracellular pH changes of cultured human lung cancer cells (A549) when exposed to titanium dioxide nanoparticles (TiO 2 NPs). Results showed that the probe has superior capability for fast, local, and continual monitoring of a small cluster of cells, which provides researchers a fast and accurate technique to conduct local pH measurements for cell heterogeneity-related studies.

  4. The Stanford-U.S. Geological Survey SHRIMP ion microprobe--a tool for micro-scale chemical and isotopic analysis

    Science.gov (United States)

    Bacon, Charles R.; Grove, Marty; Vazquez, Jorge A.; Coble, Matthew A.

    2012-01-01

    Answers to many questions in Earth science require chemical analysis of minute volumes of minerals, volcanic glass, or biological materials. Secondary Ion Mass Spectrometry (SIMS) is an extremely sensitive analytical method in which a 5–30 micrometer diameter "primary" beam of charged particles (ions) is focused on a region of a solid specimen to sputter secondary ions from 1–5 nanograms of the sample under high vacuum. The elemental abundances and isotopic ratios of these secondary ions are determined with a mass spectrometer. These results can be used for geochronology to determine the age of a region within a crystal thousands to billions of years old or to precisely measure trace abundances of chemical elements at concentrations as low as parts per billion. A partnership of the U.S. Geological Survey and the Stanford University School of Earth Sciences operates a large SIMS instrument, the Sensitive High-Resolution Ion Microprobe with Reverse Geometry (SHRIMP–RG) on the Stanford campus.

  5. Resolution 1540 (2004) overview

    International Nuclear Information System (INIS)

    Kasprzyk, N.

    2013-01-01

    This series of slides presents the Resolution 1540, its features and its status of implementation. Resolution 1540 is a response to the risk that non-State actors may acquire, develop, traffic in weapons of mass destruction and their means of delivery. Resolution 1540 was adopted on 28 April 2004 by the U.N. Security Council at the unanimity of its members. Resolution 1540 deals with the 3 kinds of weapons of mass destruction (nuclear, chemical and biological weapons) as well as 'related materials'. This resolution implies 3 sets of obligations: first no support of non-state actors concerning weapons of mass destruction, secondly to set national laws that prohibit any non-state actors to deal with weapons of mass destruction and thirdly to enforce domestic control to prevent the proliferation of nuclear, chemical or biological weapons and their means of delivery. Four working groups operated by the 1540 Committee have been settled: - Implementation (coordinator: Germany); - Assistance (coordinator: France); - International cooperation (interim coordinator: South Africa); and - Transparency and media outreach (coordinator: USA). The status of implementation of the resolution continues to improve since 2004, much work remains to be done and the gravity of the threat remains considerable. (A.C.)

  6. Rapid rock analysis and microprobe scanning of dermatological material using proton-induced x-ray and γ-ray emission

    International Nuclear Information System (INIS)

    Carlsson, L.E.

    1983-01-01

    The dissertation report comprises 6 articles that have or will appear in open literature. The use of PIXE and PIGE analysis techniques on geological materials, and also on drill cores, is discussed. The accuracy of the methods have been tested on standards. The effect of sample thickness has been studied. A proton microprobe has been compared with an electron microprobe on human skin sections. Both probes give highly reproducible results, but a small systematic deviation between the probes is found. (author)

  7. Investigation of migration an actinide imitator (Ce) in synthesis glass ceramics with a nuclear microscope

    International Nuclear Information System (INIS)

    Bondarenko, V.N.; Goncharov, A.V.; Odejchuk, M.A.; Pistryak, V.M.; Pilipenko, A.V.; Sank, S.Yu.; Sukhostaeva, V.I.; Shevstiev, A.P.

    2005-01-01

    Full text: The generally accepted conception of radioactive waste (RAW) safe disposal, so-called 'multibarrier strategy', assumes construction of several protective barriers in a geologic burial. One of these barriers is is a durable corrosion-resistant container of RAW. The glass ceramics (syntetic alumina silicate) is considered as promising material for such containers. An important parameter for long term reduction of behavior for such materials is rate of radionuclide emanation from the container. As an element whose migration in solids is analogous as that of actinide, one generally uses Cerium. For investigation of transuranium element migration Ce is used as an analogue. Accordingly, CeO 2 may serve as an imitator of transuranium oxides. In the present work Ce migration in glass ceramics has been investigated with a nuclear microprobe which is more sensitive instrument than an electron microscope. The glass ceramic material was prepared from mixture of materials powders (70 % mas. of red granite and 30% mas. of kaolin) by sintering under pressure. The hot pressing was conducted at 1050 deg. temperature and 40 MPa pressure. The endurance time continued 15 min. Manufactured alumina silicate samples were in the form of a pellet. The material density was 2.5-2.7 g/cm 3 . Pellets of imitator substance were made of CeO 2 powder by the same method. After polishing, aluminosilicate and imitator pellets were pressed together and annealed in the temperature range from 600 to 750 deg. C in vacuum during 10 hours. As a result of annealing, Ce penetration occurred thought the interface into the depth of the alumina silicate pellet. After that the pellets were separated, and the alumina silicate pellet was cleaved in the direction transversal to the former interface. The surface of cleavage of alumina silicate pellet was studied with a nuclear microprobe. For measurement of Ce diffusion distribution in alumina silicate samples we applied a nuclear microprobe on the basis

  8. The use of field indentation microprobe in measuring mechanical properties of welds

    International Nuclear Information System (INIS)

    Haggag, F.M.; Wong, H.; Alexander, D.J.; Nanstad, R.K.

    1989-01-01

    A field indentation microprobe (FIM) was conceived for evaluating the structural integrity of metallic components (including base metal, welds, and heat-affected zones) in situ in a nondestructive manner. The FIM consists of an automated ball indentation (ABI) unit for determining the mechanical properties (yield strength, flow properties, estimates of fracture toughness, etc.) and a nondestructive evaluation (NDE) unit (consisting of ultrasonic transducers and a video camera) for determining the physical properties such as crack size, material pileup around indentation, and residual stress presence and orientation. The laboratory version used in this work performs only ABI testing. ABI tests were performed on stainless steel base metal (type 316L), heat-affected zone, and welds (type 308). Excellent agreement was obtained between yield strength and flow properties (true-stress/true-plastic-strain curve) measured by the ABI tests and those from uniaxial tensile tests conducted on 308 stainless steel welds, thermally aged at 343/degree/C for different times, and on the base material. 4 refs., 17 figs

  9. Ion microprobe analyses of aluminous lunar glasses - A test of the 'rock type' hypothesis

    Science.gov (United States)

    Meyer, C., Jr.

    1978-01-01

    Previous soil survey investigations found that there are natural groupings of glass compositions in lunar soils and that the average major element composition of some of these groupings is the same at widely separated lunar landing sites. This led soil survey enthusiasts to promote the hypothesis that the average composition of glass groupings represents the composition of primary lunar 'rock types'. In this investigation the trace element composition of numerous aluminous glass particles was determined by the ion microprobe method as a test of the above mentioned 'rock type' hypothesis. It was found that within any grouping of aluminous lunar glasses by major element content, there is considerable scatter in the refractory trace element content. In addition, aluminous glasses grouped by major elements were found to have different average trace element contents at different sites (Apollo 15, 16 and Luna 20). This evidence argues that natural groupings in glass compositions are determined by regolith processes and may not represent the composition of primary lunar 'rock types'.

  10. A study of aluminium-exposed fish using a scanning proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Eeckhaoudt, S; Van Grieken, R [Universitaire Instelling Antwerpen, Antwerp (Belgium)

    1994-12-31

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs.

  11. Treatment of dentin with stannous fluoride - SEM and electron microprobe study

    International Nuclear Information System (INIS)

    Ellingsen, J.E.; Roella, G.

    1987-01-01

    The effect of SnF 2 -treatment of dentin surfaces was investigated by means of scanning electron microscopy (SEM) and electron microprobe analysis. Human dentin was treated with aqueous SnF 2 solutions of concentrations varying from 1 to 10%. The treatment periods lasted for 1, 5, 10 or 60 min. Both tin and fluoride were identified on the surfaces. The concentration varied depending on the extensiveness of the treatment. Immersion in 1 M KOH for 15 h removed both tin and fluoride from the surfaces. This reaction was not observed after immersion in H 2 O for the same time period. Examination of the SnF 2 -treated dentin surfaces showed a dense layer of globular particles and in addition some larger particles. The dentinal tubules were totally covered even after the treatment with the lowest concentration of SnF 2 . Deposition of tin- and fluoride-containing globules on dentin surfaces may be of clinical interest. This layer may have importance both for the caries resistance of dentin and for hypersensitivity reactions. (author)

  12. A study of aluminium-exposed fish using a scanning proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Eeckhaoudt, S.; Van Grieken, R. [Universitaire Instelling Antwerpen, Antwerp (Belgium)

    1993-12-31

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs.

  13. Development of an optical fiber SERS microprobe for minimally invasive sensing applications

    Science.gov (United States)

    Mamun, Md Abdullah Al; Juodkazis, Saulius; Mahadevan-Jansen, Anita; Stoddart, Paul R.

    2018-02-01

    Numerous potential biomedical sensing applications of surface-enhanced Raman scattering (SERS) have been reported, but its practical use has been limited by the lack of a robust sensing platform. Optical fiber SERS probes show great promise, but are limited by the prominent silica Raman background, which requires the use of bulky optics for filtering the signal collection and excitation delivery paths. In the present study, a SERS microprobe has been designed and developed to eliminate the bottlenecks outlined above. For efficient excitation and delivery of the SERS signal, both hollow core photonic crystal fiber and double clad fiber have been investigated. While the hollow core fiber was still found to have excessive silica background, the double clad fiber allows efficient signal collection via the multi-mode inner cladding. A micro filtering mechanism has been designed, which can be integrated into the tip of the optical fiber SERS probe, providing filtering to suppress silica Raman background and thus avoiding the need for bulky optics. The design also assists in the efficient collection of SERS signal from the sample by rejecting Rayleigh scattered light from the sample. Optical fiber cleaving using ultra-short laser pulses was tested for improved control of the fiber tip geometry. With this miniaturized and integrated filtering mechanism, it is expected that the developed probe will promote the use of SERS for minimally invasive biomedical monitoring and sensing applications in future. The probe could potentially be placed inside a small gauge hypodermic needle and would be compatible with handheld portable spectrometers.

  14. Characterisation of Inorganic Pigments Used by Selected Painters by Using Ion Microprobe and Other Complementary Techniques

    International Nuclear Information System (INIS)

    Fazinic, S.; Pastuovic, Z.; Jaksic, M.; Kusijanovic, K.; Mudronja, D.; Braun, M.; Desnica, V.

    2011-01-01

    The aim of the presentation is to show results of the collaboration between the Croatian Conservation Institute (CCI) and the Laboratory for Ion Beam Interactions of the Rudjer Boskovic Institute (RBI) established within the present CRP. CCI is the central Croatian institution for conservation and restoration of cultural heritage objects. Prior to restoration/conservation CCI performs scientific analysis of an object, primarily to enable selection of the best strategy for its restoration/conservation. In many occasions such analysis is also helpful to resolve issues such as clarification of authenticity and/or authorship of an object. CCI has its analytical laboratory which is fully dedicated to the analysis of cultural heritage and art objects. CCI analytical laboratory is equipped with various microscopy techniques, photography methods, portable X-ray Fluorescence Spectrometer (XRF) and X-ray radiography instrumentation. Access to complementary microanalytical techniques like Raman Spectroscopy or Ion Beam Analytical (IBA) techniques is provided through already long and successful collaboration with RBI. The RBI Laboratory for Ion Beam Interactions provides complementary analysis of layered microsamples by using IBA techniques, such as Particle Induced X-ray Emission (PIXE) and Rutherford Back-scattering (RBS), and for the miniature samples by using ion microprobe. (author)

  15. Using Synchrotron X-ray Fluorescence Microprobes in the Study of Metal Homeostasis in Plants

    International Nuclear Information System (INIS)

    Punshon, T.; Guerinot, M.; Lanzirotti, A.

    2009-01-01

    Background and Aims: This Botanical Briefing reviews the application of synchrotron X-ray fluorescence (SXRF) microprobes to the plant sciences; how the technique has expanded our knowledge of metal(loid) homeostasis, and how it can be used in the future. Scope: The use of SXRF microspectroscopy and microtomography in research on metal homeostasis in plants is reviewed. The potential use of SXRF as part of the ionomics toolbox, where it is able to provide fundamental information on the way that plants control metal homeostasis, is recommended. Conclusions: SXRF is one of the few techniques capable of providing spatially resolved in-vivo metal abundance data on a sub-micrometre scale, without the need for chemical fixation, coating, drying or even sectioning of samples. This gives researchers the ability to uncover mechanisms of plant metal homeostasis that can potentially be obscured by the artefacts of sample preparation. Further, new generation synchrotrons with smaller beam sizes and more sensitive detection systems will allow for the imaging of metal distribution within single living plant cells. Even greater advances in our understanding of metal homeostasis in plants can be gained by overcoming some of the practical boundaries that exist in the use of SXRF analysis.

  16. Practical aspects of quantitative laser Raman microprobe spectroscopy for the study of fluid inclusions

    International Nuclear Information System (INIS)

    Pasteris, J.D.; Wopenka, B.; Seitz, J.C.

    1988-01-01

    This paper is addressed to both geologists who use laser Raman microprobe (LRM) spectroscopy to analyze fluid inclusions and to those who want to evaluate analyses done by this technique. Emphasis is on how to obtain quantitative analyses of fluid inclusions. The authors discuss the basic method of fluid inclusion analysis by LRM spectroscopy and the levels of accuracy and precision attainable with this technique. They evaluate which kinds of fluid inclusions and host mineral matrices will yield the most reliable compositional data. Necessary sample preparations, detection limits, problems with fluorescence, dependence of Raman scattering efficiencies on density, and many other questions asked at the workshop on Raman spectroscopy during the 1987 ACROFI meeting also are addressed. The complementary nature, advantages, and disadvantages of both LRM spectroscopy and microthermometry, the two techniques most frequently used for the analysis of individual fluid inclusions, are emphasized. Some discussions are intended to held LRM users calibrate, and evaluate the optical characteristics of, their particular instruments. It is hoped that this paper will further LRM users in finding a common ground on which to discuss the differences and similarities among different LRM instruments, and that it will encourage a future consensus on efficient means of calibration and on interlaboratory standards

  17. A study of aluminium-exposed fish using a scanning proton microprobe

    International Nuclear Information System (INIS)

    Cholewa, M.; Legge, G.L.F.

    1993-01-01

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs

  18. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    International Nuclear Information System (INIS)

    Cao, H; Nguyen, C M; Chiao, J C

    2012-01-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor–liquid–solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H 2 O 2 , electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors

  19. Deposition of corrosion products from dowels on human dental root surfaces measured with proton microprobe technique

    International Nuclear Information System (INIS)

    Brune, D.; Brunell, G.; Lindh, U.

    1982-01-01

    Distribution of copper, mercury and zinc on human teeth root surfaces adjacent to dowels of gold alloy or brass as well as dowels of brass in conjunction with an amalgam crown has been measured with a proton microprobe using PIXE techniques. Upper limits of the contents of gold and silver on the root surfaces were established. Pronounced concentration profiles of copper and zinc were observed on the root surfaces of teeth prepared with dowels of brass. The dowel of gold alloy revealed only zinc deposition. The major part of copper on the root surfaces is assumed to arise from corrosion of the dowels, and has been transported to the surface by diffusion through the dential tubuli. Zinc in the volume analysed is a constituent of dentin tissue as well as a corrosion product of the brass dowel. Part of the zinc level could also be ascribed to erosion of the zinc phosphate cement matrix. The volumes analysed were (25 x 25 x 25)μm 3 . The levels of copper, mercury and zinc on the tooth root surfaces attained values up to about 200, 20 and 600 ppm, respectively. (orig.)

  20. Deposition of corrosion products from dowels on human dental root surfaces measured with proton microprobe technique

    Science.gov (United States)

    Brune, D.; Brunell, G.; Lindh, U.

    1982-06-01

    Distribution of copper, mercury and zinc on human teeth root surfaces adjacent to dowels of gold alloy or brass as well as dowels of brass in conjunction with an amalgam crown has been measured with a proton microprobe using PIXE techniques. Upper limits of the contents of gold and silver on the root surfaces were established. Pronounced concentration profiles of copper and zinc were observed on the root surfaces of teeth prepared with dowels of brass. The dowel of gold alloy revealed only zinc deposition. The major part of copper on the root surfaces is assumed to arise from corrosion of the dowels, and has been transported to the surface by diffusion through the dential tubuli. Zinc in the volume analysed is a constituent of dentin tissue as well as a corrosion product of the brass dowel. Part of the zinc level could also be ascribed to erosion of the zinc phosphate cement matrix. The volumes analysed were (25×25×25)μm 3. The levels of copper, mercury and zinc on the tooth root surfaces attained values up to about 200, 20 and 600 ppm, respectively.

  1. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    Science.gov (United States)

    Cao, H.; Nguyen, C. M.; Chiao, J. C.

    2012-06-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor-liquid-solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H2O2, electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors.

  2. U Y 105 standard use of non sealed radioactive sources in nuclear medicine: approve for Industry energy and Mining Ministry 28/6/2002 Resolution

    International Nuclear Information System (INIS)

    2002-01-01

    Establish minimal requirements radiological safety for use non sealed radioactive sources in nuclear medicine.The present standard is used in operation or nuclear medicine practices using non sealed radioactive sources with diagnostic and therapeutic purposes in vivo and in vitro

  3. High spatial resolution measurement of depth-of-interaction of a PET LSO crystal

    International Nuclear Information System (INIS)

    Simon, A.; Kalinka, G.; Novak, D.; Sipos, A.; Vegh, J.; Molnar, J.

    2004-01-01

    Complete text of publication follows. A new type of experimental technique to investigate the depth-of-interaction (DOI) dependence in small scintillator elements designed for high-resolution animal PET [1] has been introduced at our institute, recently. A lutetium oxyorthosilicate (LSO) crystal (2x2x10 mm 3 ) was irradiated with a highly focused 2 MeV He + beam at the ATOMKI nuclear microprobe laboratory. Pulse height spectra from a photomultiplier (PMT) attached to one end of the LSO crystal were collected in list mode. Sequential scans of 1000x1000 μm 2 areas along the 10 mm long crystal were made to get high lateral resolution images of pulse height spectra at different distances from the window of the PMT. A mean pulse height algorithm was applied to each pixel to generate two dimensional intensity images and the corresponding spectra of 100 μmx1 mm areas. Representative pulse height spectra are shown in Fig. 1 for different distances between the position of irradiation and the PMT. The mean value of the pulse height spectrum describing the position of the full energy peak is a way to measure DOI effects. It is seen that the closer the DOI to the PMT-end of the crystal the higher the energy of the peak. The centre of the detected peak varies about 30 % along the lateral side of the crystal. This effect is due to the increasing number of reflections with associated loss of light when the distance between the DOI position and the light collecting PMT grows. Further these results, no difference in the light intensity was found depending on which position across (perpendicular to the length of) the crystal was irradiated with the microbeam. The obtained results of the overall DOI dependence confirm previous measurements on LSO crystals with similar geometry and wrapping but based on collimated gamma-ray irradiation. Since the present experimental setup allows obtaining data with several orders of magnitude better spatial resolution (from μm up to mm) than with

  4. Materials of the Second Sumy-Cracow-Muenster Symposium on Nuclear Analytical Methods

    International Nuclear Information System (INIS)

    2001-01-01

    The applications of nuclear analytical methods in physico-chemical, biological and medical studies have been presented in large number of applications. Environmental, geological and biological materials have been analysed by means of neutron activation analysis, proton microprobe, x-ray diffraction, synchrotron radiation X-ray spectrum analysis, ESR and others

  5. Evaluation of toxicological effects induced by tributyltin in clam Ruditapes decussatus using high-resolution magic angle spinning nuclear magnetic resonance spectroscopy: Study of metabolic responses in heart tissue and detection of a novel metabolite

    OpenAIRE

    Hanana, H.; Simon, G.; Kervarec, N.; Cérantola, S.

    2014-01-01

    Tributyltin (TBT) is a highly toxic pollutant present in many aquatic ecosystems. Its toxicity in mollusks strongly affects their performance and survival. The main purpose of this study was to elucidate the mechanisms of TBT toxicity in clam Ruditapes decussatus by evaluating the metabolic responses of heart tissues, using high-resolution magic angle-spinning nuclear magnetic resonance (HRMAS NMR), after exposure to TBT (10−9, 10−6 and 10−4 M) during 24 h and 72 h. Results show that response...

  6. CALCMIN - an EXCEL™ Visual Basic application for calculating mineral structural formulae from electron microprobe analyses

    Science.gov (United States)

    Brandelik, Andreas

    2009-07-01

    CALCMIN, an open source Visual Basic program, was implemented in EXCEL™. The program was primarily developed to support geoscientists in their routine task of calculating structural formulae of minerals on the basis of chemical analysis mainly obtained by electron microprobe (EMP) techniques. Calculation programs for various minerals are already included in the form of sub-routines. These routines are arranged in separate modules containing a minimum of code. The architecture of CALCMIN allows the user to easily develop new calculation routines or modify existing routines with little knowledge of programming techniques. By means of a simple mouse-click, the program automatically generates a rudimentary framework of code using the object model of the Visual Basic Editor (VBE). Within this framework simple commands and functions, which are provided by the program, can be used, for example, to perform various normalization procedures or to output the results of the computations. For the clarity of the code, element symbols are used as variables initialized by the program automatically. CALCMIN does not set any boundaries in complexity of the code used, resulting in a wide range of possible applications. Thus, matrix and optimization methods can be included, for instance, to determine end member contents for subsequent thermodynamic calculations. Diverse input procedures are provided, such as the automated read-in of output files created by the EMP. Furthermore, a subsequent filter routine enables the user to extract specific analyses in order to use them for a corresponding calculation routine. An event-driven, interactive operating mode was selected for easy application of the program. CALCMIN leads the user from the beginning to the end of the calculation process.

  7. Sulphur isotope variations in the mantle from ion microprobe analyses of micro-sulphide inclusions

    International Nuclear Information System (INIS)

    Chaussidon, M.; Albarede, F.; Sheppard, S.M.F.

    1989-01-01

    21 samples of sulphide trapped either as liquid globules or grains in various minerals (olivine, pyroxenes, ilmenite and garnet) or rocks (basalt glasses, peridotites, eclogites and kimberlites) of mantle origin, have been analysed for their sulphur isotope, and their Cu, Ni, Fe compositions by ion microprobe. The results show a wide range of δ 34 S values between -4.9±1 and +8±1per mille. Sulphides with high nickel contents (up to 40% pentlandite), corresponding mostly to residual peridotites, have δ 34 S values ranging from -3.2per mille to +3.6per mille with a mode of +3±1per mille, compared to low Ni content sulphides, mostly contained in pyroxenites, OIB and kimberlites, ranging from -3.6per mille to +8per mille with a mode of +1±1per mille. The δ 34 S of sulphides originating from within the mantle are variable. The sulphide globules with high Ni contents and δ 34 S values close to +3per mille, are probably produced by 10-20% partial melting of a mantle source containing 300 ppm sulphur as an upper limit and having a δ 34 S value of +0.5±0.5per mille. This difference in δ 34 S values suggests a high-temperature S-isotope fractionation of ≅+3per mille between liquid sulphide and the sulphur dissolved in the silicate liquid. The sulphur isotopes balance in the system upper mantle + oceanic crust + continental crust + seawater requires a mean δ 34 S value of the primitive upper mantle of +0.5per mille, slightly but significantly different from that of chondrites (+0.2±0.2per mille). (orig.)

  8. Assessment of dye distribution in sensitized solar cells by microprobe techniques

    Energy Technology Data Exchange (ETDEWEB)

    Barreiros, M.A., E-mail: alexandra.barreiros@lneg.pt [Laboratório Nacional de Energia e Geologia, LEN/UES, Estrada do Paço do Lumiar, 22, 1649-038 Lisboa (Portugal); Corregidor, V. [IPFN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10, 2686-953 Sacavém (Portugal); Alves, L.C. [C2TN, Campus Tecnológico e Nuclear, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10, 2686-953 Sacavém (Portugal); Guimarães, F. [Laboratório Nacional de Energia e Geologia, LGM/UCTM, Rua da Amieira, Apartado 1089, 4466-901 S. Mamede de Infesta (Portugal); Mascarenhas, J.; Torres, E.; Brites, M.J. [Laboratório Nacional de Energia e Geologia, LEN/UES, Estrada do Paço do Lumiar, 22, 1649-038 Lisboa (Portugal)

    2015-04-01

    Dye sensitized solar cells (DSCs) have received considerable attention once this technology offers economic and environmental advantages over conventional photovoltaic (PV) devices. The PV performance of a DSC relies on the characteristics of its photoanode, which typically consists of a nanocrystalline porous TiO{sub 2} film, enabled with a large adsorptive surface area. Dye molecules that capture photons from light during device operation are attached to the film nanoparticles. The effective loading of the dye in the TiO{sub 2} electrode is of paramount relevance for controlling and optimizing solar cell parameters. Relatively few methods are known today for quantitative evaluation of the total dye adsorbed on the film. In this context, microprobe techniques come out as suitable tools to evaluate the dye surface distribution and depth profile in sensitized films. Electron Probe Microanalysis (EPMA) and Ion Beam Analytical (IBA) techniques using a micro-ion beam were used to quantify and to study the distribution of the Ru organometallic dye in TiO{sub 2} films, making use of the different penetration depth and beam sizes of each technique. Different 1D nanostructured TiO{sub 2} films were prepared, morphologically characterized by SEM, sensitized and analyzed by the referred techniques. Dye load evaluation in different TiO{sub 2} films by three different techniques (PIXE, RBS and EPMA/WDS) provided similar results of Ru/Ti mass fraction ratio. Moreover, it was possible to assess dye surface distribution and its depth profile, by means of Ru signal, and to visualize the dye distribution in sample cross-section through X-ray mapping by EPMA/EDS. PIXE maps of Ru and Ti indicated an homogeneous surface distribution. The assessment of Ru depth profile by RBS showed that some films have homogeneous Ru depth distribution while others present different Ru concentration in the top layer (2 μm thickness). These results are consistent with the EPMA/EDS maps obtained.

  9. Quantifying trace elements in individual aquatic protist cells with a synchrotron x-ray fluorescence microprobe

    International Nuclear Information System (INIS)

    Twining, B.S.; Baines, S.B.; Fisher, N.S.; Maser, J.; Vogt, S.; Jacobsen, C.; Tovar-Sanchez, A.; Sanudo-Wihelmy, S.A.

    2003-01-01

    The study of trace metal cycling by aquatic protists is limited by current analytical techniques. Standard 'bulk' element analysis techniques that rely on physical separations to concentrate cells for analysis cannot separate cells from co-occurring detrital material or other cells of differing taxonomy or trophic function. Here we demonstrate the ability of a synchrotron-based X-ray fluorescence (SXRF) microprobe to quantify the elements Si, Mn, Fe, Ni, and Zn in individual aquatic protist cells. This technique distinguishes between different types of cells in an assemblage and between cells and other particulate matter. Under typical operating conditions, the minimum detection limits are 7.0 x 10 -16 mol μm -2 for Si and between 5.0 x 10 -20 and 3.9 x 10 -19 mol μm -2 for Mn, Fe, Ni, and Zn; this sensitivity is sufficient to detect these elements in cells from even the most pristine waters as demonstrated in phytoplankton cells collected from remote areas of the Southern Ocean. Replicate analyses of single cells produced variations of <5% for Si, Mn, Fe, and Zn and <10% for Ni. Comparative analyses of cultured phytoplankton cells generally show no significant differences in cellular metal concentrations measured with SXRF and standard bulk techniques (spectrophotometry and graphite furnace atomic absorption spectrometry). SXRF also produces two-dimensional maps of element distributions in cells, thereby providing information not available with other analytical approaches. This technique enables the accurate and precise measurement of trace metals in individual aquatic protists collected from natural environments.

  10. A new approach to nuclear microscopy: The ion-electron emission microscope

    International Nuclear Information System (INIS)

    Doyle, B.L.; Vizkelethy, G.; Walsh, D.S.; Senftinger, B.; Mellon, M.

    1998-01-01

    A new multidimensional high lateral resolution ion beam analysis technique, Ion-Electron Emission Microscopy or IEEM is described. Using MeV energy ions, IEEM is shown to be capable of Ion Beam Induced Charge Collection (IBICC) measurements in semiconductors. IEEM should also be capable of microscopically and multidimensionally mapping the surface and bulk composition of solids. As such, IIEM has nearly identical capabilities as traditional nuclear microprobe analysis, with the advantage that the ion beam does not have to be focused. The technique is based on determining the position where an individual ion enters the surface of the sample by projection secondary electron emission microscopy. The x-y origination point of a secondary electron, and hence the impact coordinates of the corresponding incident ion, is recorded with a position sensitive detector connected to a standard photoemission electron microscope (PEEM). These signals are then used to establish coincidence with IBICC, atomic, or nuclear reaction induced ion beam analysis signals simultaneously caused by the incident ion

  11. Nuclear networking.

    Science.gov (United States)

    Xie, Wei; Burke, Brian

    2017-07-04

    Nuclear lamins are intermediate filament proteins that represent important structural components of metazoan nuclear envelopes (NEs). By combining proteomics and superresolution microscopy, we recently reported that both A- and B-type nuclear lamins form spatially distinct filament networks at the nuclear periphery of mouse fibroblasts. In particular, A-type lamins exhibit differential association with nuclear pore complexes (NPCs). Our studies reveal that the nuclear lamina network in mammalian somatic cells is less ordered and more complex than that of amphibian oocytes, the only other system in which the lamina has been visualized at high resolution. In addition, the NPC component Tpr likely links NPCs to the A-type lamin network, an association that appears to be regulated by C-terminal modification of various A-type lamin isoforms. Many questions remain, however, concerning the structure and assembly of lamin filaments, as well as with their mode of association with other nuclear components such as peripheral chromatin.

  12. Immediate tasks in realization of 52-53 Sessions of United Nations Organization General Assembly resolution on Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Ibraev, S.

    2000-01-01

    The author points out, that ecological heritage of Semipalatinsk test site is not studied, scattered investigations does not give objective assessment about radiation situation in the region. Only operations of close down of wells on the base of inter-state agreement between Republic of Kazakhstan and the United States of America were carried out. There are following main rehabilitation measures on liquidation of nuclear tests consequences in the region: study, deactivation and re-cultivation of populated territories; study of radioactive contamination level in underground waters and definition radionuclides migration by biological chain for taking preventative measures. It is noted, that citizens of the region with gratitude took solution of 52-53 Sessions of United Nations Organization General Assembly 'On liquidation of nuclear tests consequences on Semipalatinsk nuclear test site

  13. Resolution proposition on the acknowledgement of a presumption of a causality relationship between exposure to radiations after a nuclear accident and disease or decease

    International Nuclear Information System (INIS)

    2011-01-01

    This document makes reference to the Chernobyl accident and to the subsequent contamination which occurred in the eastern part of France and Corsica, and also to the fact that a prevalence of thyroid cancers has been noticed in Corsica. Based on these elements, the authors propose a legislative resolution for the recognition of the fact that this radioactivity is responsible for their disease

  14. Integration of a silicon-based microprobe into a gear measuring instrument for accurate measurement of micro gears

    International Nuclear Information System (INIS)

    Ferreira, N; Krah, T; Jeong, D C; Kniel, K; Härtig, F; Metz, D; Dietzel, A; Büttgenbach, S

    2014-01-01

    The integration of silicon micro probing systems into conventional gear measuring instruments (GMIs) allows fully automated measurements of external involute micro spur gears of normal modules smaller than 1 mm. This system, based on a silicon microprobe, has been developed and manufactured at the Institute for Microtechnology of the Technische Universität Braunschweig. The microprobe consists of a silicon sensor element and a stylus which is oriented perpendicularly to the sensor. The sensor is fabricated by means of silicon bulk micromachining. Its small dimensions of 6.5 mm × 6.5 mm allow compact mounting in a cartridge to facilitate the integration into a GMI. In this way, tactile measurements of 3D microstructures can be realized. To enable three-dimensional measurements with marginal forces, four Wheatstone bridges are built with diffused piezoresistors on the membrane of the sensor. On the reverse of the membrane, the stylus is glued perpendicularly to the sensor on a boss to transmit the probing forces to the sensor element during measurements. Sphere diameters smaller than 300 µm and shaft lengths of 5 mm as well as measurement forces from 10 µN enable the measurements of 3D microstructures. Such micro probing systems can be integrated into universal coordinate measuring machines and also into GMIs to extend their field of application. Practical measurements were carried out at the Physikalisch-Technische Bundesanstalt by qualifying the microprobes on a calibrated reference sphere to determine their sensitivity and their physical dimensions in volume. Following that, profile and helix measurements were carried out on a gear measurement standard with a module of 1 mm. The comparison of the measurements shows good agreement between the measurement values and the calibrated values. This result is a promising basis for the realization of smaller probe diameters for the tactile measurement of micro gears with smaller modules. (paper)

  15. Novel Magnetic Microprobe with Benzoboroxole-Modified Flexible Multisite Arm for High-Efficiency cis-Diol Biomolecule Detection.

    Science.gov (United States)

    Chen, Guosheng; Huang, Siming; Kou, Xiaoxue; Zhang, Jin'ge; Wang, Fuxin; Zhu, Fang; Ouyang, Gangfeng

    2018-03-06

    With regard to regulating a variety of biological events, including molecular recognition, signal transduction, cell adhesion, and immune response, cis-diol biomolecules, such as saccharides and glycoproteins, play vital roles. However, saccharides and glycoproteins in living systems usually exist in very low abundance, along with abundant interfering components. High-efficiency detection of saccharides and glycoproteins is a challenging yet highly impactful area of research. Herein, we reported a novel magnetic microprobe with a benzoboroxole-modified flexible multisite arm (PEG 2000-grafted PAMAM dendrimers; the microprobe was denoted as BFMA-MNP) for high-efficiency saccharides detection. The extraction capacity was significantly improved by ∼2 orders of magnitude, because of the integration of the enhanced hydrophilicity and multivalency effects in benzoboroxoles and the enhanced accessibility of the binding sites within the PEG 2000-grafted PAMAM dendrimers. As a result, the proposed approach possessed several advantages, compared with previous boronic acid-based methods, including ultrahigh sensitivity (limit of detection was <1 ng/mL), wide linear range (ranged from 0.5 μM to 2000 μM), and applicable in physiological pH condition. Furthermore, we established a general BFMA-MNP/glycoproteins/AuNPs sandwich assay to realize the visual glycoprotein qualitative screening for the first time. The unique sandwich assay possessed the dual nature of the magnetic separation by BFMA-MNPs and specific coloration by citrate-coated AuNPs. This visual sandwich assay enabled fast differentiation of the existence of glycoproteins in complicated samples without any advanced instruments. We believe the proposed BFMA-MNP microprobe herein will advance the ideas to detect and identify trace saccharides and glycoproteins in important fields such as glycomics and glycoproteomics.

  16. Resolution propositions

    International Nuclear Information System (INIS)

    2003-05-01

    To put a resolution to the meeting in relation with the use of weapons made of depleted uranium is the purpose of this text. The situation of the use of depleted uranium by France during the Gulf war and other recent conflicts will be established. This resolution will give the most strict recommendations face to the eventual sanitary and environmental risks in the use of these kind of weapons. (N.C.)

  17. Preliminary study of Tl and Cd uptake in the heavy metal accumulating Brassica napus using the Debrecen proton microprobe

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Haag-Kerwer, A.; Povh, B.

    2003-01-01

    The high biomass producing crop plants, Brassica juncea L. and Brassica napus are very promising plant species for phytoremediation. The aim of further research is to help a better understanding of the transport mechanism within roots and roots to shoots of heavy metals, and to find out their distribution and translocation among different cell types in the root of these species. The distribution and concentration of major and trace elements was determined along the roots of Cd and Tl treated as well as control plants of Brassica napus on the ATOMKI proton microprobe. (R.P.)

  18. Redeposition of sputtered material in a glow-discharge lamp measured by means of an ion microprobe mass analyser

    International Nuclear Information System (INIS)

    Ferreira, N.P.; Bueger, P.A.

    1978-01-01

    The redeposition of sputtered material on the target in a Grimm-type glow-discharge lamp was studied by means of an ion microprobe mass analyser (IMMA) using 16 O 2 + ions as bombarding species. The target was an aluminium disc with a cylindrical copper insertion, one mm in diameter. The lamp was operated at currents of 50 mA and 100 mA and a voltage of 1200 V. It is estimated that 17% of the copper atoms sputtered are redeposited and may be resputtered. (orig.) [de

  19. Evolution of the Gondwanaland Archaean Shield: ion microprobe zircon dating and southwestern Australia/Wilkes Land, Antartica

    International Nuclear Information System (INIS)

    Lovering, J.F.; Comaford, D.J.

    1979-01-01

    The ion microprobe has been used to study 207 Pb/ 206 Pb ages on 20μm-sized sites on single zircon grains from coastal rocks on either side of the rift in the Gondwanaland Archaean Shield between southwestern Australia and Wilkes Land, Antarctica. The ages on individual sites on zircon grains from a variety of rock types from southwestern Australia show a range from 1600 m.y. to about 3400 m.y., with an inverse dependence on the uranium abundance at each site. Ages of zircons from rocks from the Antartic region show a range from 1600 m.y. to 3100 m.y

  20. High-Resolution Nuclear Magnetic Resonance Determination of Transfer RNA Tertiary Base Pairs in Solution. 2. Species Containing a Large Variable Loop

    NARCIS (Netherlands)

    HURD, RE; ROBILLARD, GT; REID, BR

    1977-01-01

    The number of base pairs in the solution structure of several class III D3VN tRNA species from E. coli has been determined by analyzing the number of low-field (-15 to -11 ppm) proton resonances in their nuclear magnetic resonance spectra at 360 MHz. Contrary to previous reports indicating the

  1. CONCH: A Visual Basic program for interactive processing of ion-microprobe analytical data

    Science.gov (United States)

    Nelson, David R.

    2006-11-01

    A Visual Basic program for flexible, interactive processing of ion-microprobe data acquired for quantitative trace element, 26Al- 26Mg, 53Mn- 53Cr, 60Fe- 60Ni and U-Th-Pb geochronology applications is described. Default but editable run-tables enable software identification of secondary ion species analyzed and for characterization of the standard used. Counts obtained for each species may be displayed in plots against analysis time and edited interactively. Count outliers can be automatically identified via a set of editable count-rejection criteria and displayed for assessment. Standard analyses are distinguished from Unknowns by matching of the analysis label with a string specified in the Set-up dialog, and processed separately. A generalized routine writes background-corrected count rates, ratios and uncertainties, plus weighted means and uncertainties for Standards and Unknowns, to a spreadsheet that may be saved as a text-delimited file. Specialized routines process trace-element concentration, 26Al- 26Mg, 53Mn- 53Cr, 60Fe- 60Ni, and Th-U disequilibrium analysis types, and U-Th-Pb isotopic data obtained for zircon, titanite, perovskite, monazite, xenotime and baddeleyite. Correction to measured Pb-isotopic, Pb/U and Pb/Th ratios for the presence of common Pb may be made using measured 204Pb counts, or the 207Pb or 208Pb counts following subtraction from these of the radiogenic component. Common-Pb corrections may be made automatically, using a (user-specified) common-Pb isotopic composition appropriate for that on the sample surface, or for that incorporated within the mineral at the time of its crystallization, depending on whether the 204Pb count rate determined for the Unknown is substantially higher than the average 204Pb count rate for all session standards. Pb/U inter-element fractionation corrections are determined using an interactive log e-log e plot of common-Pb corrected 206Pb/ 238U ratios against any nominated fractionation-sensitive species pair

  2. Nuclear microprobe investigation of the penetration of ultrafine zinc oxide into human skin affected by atopic dermatitis

    Science.gov (United States)

    Szikszai, Z.; Kertész, Zs.; Bodnár, E.; Borbíró, I.; Angyal, A.; Csedreki, L.; Furu, E.; Szoboszlai, Z.; Kiss, Á. Z.; Hunyadi, J.

    2011-10-01

    Skin penetration is one of the potential routes for nanoparticles to gain access into the human body. Ultrafine metal oxides, such as titanium dioxide and zinc oxide are widely used in cosmetic and health products like sunscreens. These oxides are potent UV filters and the particle size smaller than 200 nm makes the product more transparent compared to formulations containing coarser particles. The present study continues the work carried out in the frame of the NANODERM: “Quality of skin as a barrier to ultrafine particles” European project and complements our previous investigations on human skin with compromised barrier function. Atopic dermatitis (a type of eczema) is an inflammatory, chronically relapsing, non-contagious skin disease. It is very common in children but may occur at any age. The exact cause of atopic dermatitis is unknown, but is likely due to a combination of impaired barrier function together with a malfunction in the body's immune system. In this study, skin samples were obtained from two patients suffering from atopic dermatitis. Our results indicate that the ultrafine zinc oxide particles, in a hydrophobic basis gel with an application time of 2 days or 2 weeks, have penetrated deeply into the stratum corneum in these patients. On the other hand, penetration into the stratum spinosum was not observed even in the case of the longer application time.

  3. Assembling of a low energy ion beam analysis facility and use of Nuclear Microprobe techniques in geological studies

    Energy Technology Data Exchange (ETDEWEB)

    Utui, R

    1996-11-01

    In this work, both PIXE and ion beam induced luminescence, or just Ionoluminescence (IL) were used for geochemical studies. The possibility of rapid absolute quantification of elements in the ppm level by PIXE combined with the yet higher sensitivity of IL to transition metals and Rare Earth Elements (REE) activators, in the absence of quenching phenomena, allow for a synergic use of the two methods in geological applications with enhanced sensitivity. IL and PIXE were combined for studying REE distribution in apatite minerals and ion beam induced damage in inorganic material in general with emphasis to synthetically grown zircon crystals doped with REE. Due to the sensitivity of IL to changes in chemical bonding in the material, beam damage effects can be studied even at low integrated doses, through wavelength shift or fading of the induced light. Micro PIXE technique was used for studying profile concentrations of trace elements in pyrite grains and of elements used as geothermometers. Geothermometry allowed to assess the cooling rates in iron meteorites and the mineralization conditions in metamorphic rocks, attempting to describe the tectonic history of the terranes, with application in petrologic studies and geological prospecting. 148 refs.

  4. Assembling of a low energy ion beam analysis facility and use of Nuclear Microprobe techniques in geological studies

    International Nuclear Information System (INIS)

    Utui, R.

    1996-11-01

    In this work, both PIXE and ion beam induced luminescence, or just Ionoluminescence (IL) were used for geochemical studies. The possibility of rapid absolute quantification of elements in the ppm level by PIXE combined with the yet higher sensitivity of IL to transition metals and Rare Earth Elements (REE) activators, in the absence of quenching phenomena, allow for a synergic use of the two methods in geological applications with enhanced sensitivity. IL and PIXE were combined for studying REE distribution in apatite minerals and ion beam induced damage in inorganic material in general with emphasis to synthetically grown zircon crystals doped with REE. Due to the sensitivity of IL to changes in chemical bonding in the material, beam damage effects can be studied even at low integrated doses, through wavelength shift or fading of the induced light. Micro PIXE technique was used for studying profile concentrations of trace elements in pyrite grains and of elements used as geothermometers. Geothermometry allowed to assess the cooling rates in iron meteorites and the mineralization conditions in metamorphic rocks, attempting to describe the tectonic history of the terranes, with application in petrologic studies and geological prospecting. 148 refs

  5. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    International Nuclear Information System (INIS)

    Cao, Y.; Leroux, P.; De Cock, W.; Steyaert, M.

    2011-01-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma (ΔΣ) TDC structure is proposed. The converter, implemented in 0.13 μm, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm 2 . Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g m biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  6. Design and assessment of a 6 ps-resolution time-to-digital converter with 5 MGy gamma-dose tolerance for nuclear instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Y. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Leroux, P. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium); ICT-RELIC Div., Katholieke Hogeschool Kempen, B-2440 Geel (Belgium); De Cock, W. [SCK.CEN, Belgian Nuclear Research Centre, B-2400 Mol (Belgium); Steyaert, M. [ESAT-MICAS Div., Katholieke Universiteit Leuven, B-3001 Heverlee (Belgium)

    2011-07-01

    Time-to-Digital Converters (TDCs) are key building blocks in time-based mixed-signal systems, used for the digitization of analog signals in time domain. A short survey on state-of-the-art TDCs is given. In order to realize a TDC with picosecond time resolution as well as multi MGy gamma-dose radiation tolerance, a novel multi-stage noise-shaping (MASH) delta-sigma ({Delta}{Sigma}) TDC structure is proposed. The converter, implemented in 0.13 {mu}m, achieves a time resolution of 5.6 ps and an ENOB of 11 bits, when the over sampling ratio (OSR) is 250. The TDC core consumes only 1.7 mW, and occupies an area of 0.11 mm{sup 2}. Owing to the usage of circuit level radiation hardened-by-design techniques, such as passive RC oscillators and constant-g{sub m} biasing, the TDC exhibits enhanced radiation tolerance. At a low dose rate of 1.2 kGy/h, the frequency of the counting clock in the TDC remains constant up to at least 160 kGy. Even after a total dose of 3.4 MGy at a high dose rate of 30 kGy/h, the TDC still achieves a time resolution of 10.5 ps with an OSR of 250. (authors)

  7. Nuclear nonproliferation

    International Nuclear Information System (INIS)

    Neubert, M.

    1992-01-01

    The following motion was put before the United Kingdom House of Commons on 3rd February 1992 and agreed; that this House, recognising the potential dangers of the rapidly changing world order, welcomes the recent proposals for substantial reductions in nuclear weaponry, the growing support for the non-proliferation treaty and progress in the implementation of the United Nations Security Council Resolutions concerning the dismantling of Iraqi nuclear, chemical and biological capabilities; urges the Government to play their full part in helping the relevant authorities in the Commonwealth of Independent States to dismantle their nuclear devices, to safeguard their nuclear components and to discourage the proliferation of nuclear expertise; and believes it is of the first importance that Britain retains an effective and credible minimum nuclear deterrent as security in a world where there remain many sources of instability. The record of arguments for and against the motion in the debate is presented. (author)

  8. Structure and aqueous reactivity of silicate glasses high-resolution nuclear magnetic resonance contribution; Structure et reactivite aqueuse des verres silicates apport de la resonance magnetique nucleaire haute-resolution

    Energy Technology Data Exchange (ETDEWEB)

    Angeli, F

    2000-10-25

    This research aims at getting a better understanding of the relations which may exist between the chemical composition of the oxide silicate glasses, the structure and the aqueous reactivity. We study the cations present in most glasses, more particularly the radioactive waste glasses, and those which are more liable to bring information both about structure and reactivity. Among the experimental methods used, the nuclear magnetic resonance of multi-quantum magic-angle spinning (NMR MQ-MAS) has been carried out for the structural characterization of the pristine and altered glasses. In the first part, we discuss the possibility of deducting a type of information from a quantitative approach of the {sup 23}Na, {sup 27}Al and {sup 17}O NMR MQ-MAS. In the second part, we apply this method to glasses containing between two and six oxides. The vitreous compositions studied permit to focus our attention on the influence of sodium, aluminum and calcium on their local structural environment. We point out an evolution of the distributions of bond distances and angles in relation to the glass chemical composition. We show the strong potentiality of the {sup 17}O used to probe the pristine and altered glasses. The influence of the different cations studied on the rate of glass dissolution is debated from the alterations made on short periods. On the basis of all these data, we discuss the importance of the structural effect which may influence the kinetic phenomena of alteration. (author)

  9. Initial spread of "1"3"7Cs from the Fukushima Dai-ichi Nuclear Power Plant over the Japan continental shelf. A study using a high-resolution, global-coastal nested ocean model

    International Nuclear Information System (INIS)

    Lai, Z.; Chen, C.; Lin, H.; Shanghai Ocean Univ.; Beardsley, R.; Ji, R.; Shanghai Ocean Univ.; Sasaki, J.; Lin, J.

    2013-01-01

    The 11 March 2011 tsunami triggered by the M9 and M7.9 earthquakes off the Tohoku coast destroyed facilities at the Fukushima Dai-ichi Nuclear Power Plant (FNPP) leading to a significant long-term flow of the radionuclide "1"3"7Cs into coastal waters. A high-resolution, global-coastal nested ocean model was first constructed to simulate the 11 March tsunami and coastal inundation. Based on the model's success in reproducing the observed tsunami and coastal inundation, model experiments were then conducted with differing grid resolution to assess the initial spread of "1"3"7Cs over the eastern shelf of Japan. The "1"3"7Cs was tracked as a conservative tracer (without radioactive decay) in the three-dimensional model flow field over the period of 26 March-31 August 2011. The results clearly show that for the same "1"3"7Cs discharge, the model-predicted spreading of "1"3"7Cs was sensitive not only to model resolution but also the FNPP seawall structure. A coarse-resolution (∝2 km) model simulation led to an overestimation of lateral diffusion and thus faster dispersion of "1"3"7Cs from the coast to the deep ocean, while advective processes played a more significant role when the model resolution at and around the FNPP was refined to ∝5 m. By resolving the pathways from the leaking source to the southern and northern discharge canals, the high-resolution model better predicted the "1"3"7Cs spreading in the inner shelf where in situ measurements were made at 30 km off the coast. The overestimation of "1"3"7Cs concentration near the coast is thought to be due to the omission of sedimentation and biogeochemical processes as well as uncertainties in the amount of "1"3"7Cs leaking from the source in the model. As a result, a biogeochemical module should be included in the model for more realistic simulations of the fate and spreading of "1"3"7Cs in the ocean.

  10. Initial spread of {sup 137}Cs from the Fukushima Dai-ichi Nuclear Power Plant over the Japan continental shelf. A study using a high-resolution, global-coastal nested ocean model

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Z. [Sun Yat-Sen Univ., Guangzhou (China). School of Marine Sciences; Univ. of Massachusetts-Dartmouth, New Bedford, MA (United States). School for Marine Science and Technology; Key Laboratory of Marine Resources and Coastal Engineering in Guangdong Province, Guangzhou (China); Chen, C.; Lin, H. [Univ. of Massachusetts-Dartmouth, New Bedford, MA (United States). School for Marine Science and Technology; Shanghai Ocean Univ. (China). International Center for Marine Studies; Beardsley, R. [Woods Hole Oceanographic Institution, Woods Hole, MA (United States). Dept. of Physical Oceanography; Ji, R. [Woods Hole Oceanographic Institution, Woods Hole, MA (United States). Dept. of Biology; Shanghai Ocean Univ. (China). International Center for Marine Studies; Sasaki, J. [The Univ. of Tokyo, Kashiwa (Japan). Dept. of Socio-Cultural Environmental Studies; Lin, J. [Woods Hole Oceanographic Institution, Woods Hole, MA (United States). Dept. of Geology and Geophysics

    2013-07-01

    The 11 March 2011 tsunami triggered by the M9 and M7.9 earthquakes off the Tohoku coast destroyed facilities at the Fukushima Dai-ichi Nuclear Power Plant (FNPP) leading to a significant long-term flow of the radionuclide {sup 137}Cs into coastal waters. A high-resolution, global-coastal nested ocean model was first constructed to simulate the 11 March tsunami and coastal inundation. Based on the model's success in reproducing the observed tsunami and coastal inundation, model experiments were then conducted with differing grid resolution to assess the initial spread of {sup 137}Cs over the eastern shelf of Japan. The {sup 137}Cs was tracked as a conservative tracer (without radioactive decay) in the three-dimensional model flow field over the period of 26 March-31 August 2011. The results clearly show that for the same {sup 137}Cs discharge, the model-predicted spreading of {sup 137}Cs was sensitive not only to model resolution but also the FNPP seawall structure. A coarse-resolution (∝2 km) model simulation led to an overestimation of lateral diffusion and thus faster dispersion of {sup 137}Cs from the coast to the deep ocean, while advective processes played a more significant role when the model resolution at and around the FNPP was refined to ∝5 m. By resolving the pathways from the leaking source to the southern and northern discharge canals, the high-resolution model better predicted the {sup 137}Cs spreading in the inner shelf where in situ measurements were made at 30 km off the coast. The overestimation of {sup 137}Cs concentration near the coast is thought to be due to the omission of sedimentation and biogeochemical processes as well as uncertainties in the amount of {sup 137}Cs leaking from the source in the model. As a result, a biogeochemical module should be included in the model for more realistic simulations of the fate and spreading of {sup 137}Cs in the ocean.

  11. The role of nuclear analytical techniques in the study of aqueous corrosion of glasses

    International Nuclear Information System (INIS)

    Trocellier, P.

    1984-01-01

    Direct observation of resonant nuclear reactions, backscattering spectrometry and X ray microanalysis with a nuclear microprobe were used to determine elementary depth profiles in the near surface region of leached glasses. Some computing programs required to interpretate the analytical information detected were built. Experimental conditions to characterize glass samples without secondary effects were defined; and the influence of some leaching parameters was studied to describe the first stages of aqueous corrosion of borosilicate glasses [fr

  12. Optically continuous silcrete quartz cements of the St. Peter Sandstone: High precision oxygen isotope analysis by ion microprobe

    Science.gov (United States)

    Kelly, Jacque L.; Fu, Bin; Kita, Noriko T.; Valley, John W.

    2007-08-01

    A detailed oxygen isotope study of detrital quartz and authigenic quartz overgrowths from shallowly buried (ratio by laser fluorination, resulting in an average δ 18O of 10.0 ± 0.2‰ (1SD, n = 109). Twelve thin sections were analyzed by CAMECA-1280 ion microprobe (6-10 μm spot size, analytical precision better than ±0.2‰, 1SD). Detrital quartz grains have an average δ 18O of 10.0 ± 1.4‰ (1SD, n = 91) identical to the data obtained by laser fluorination. The ion microprobe data reveal true variability that is otherwise lost by homogenization of powdered samples necessary for laser fluorination. Laser fluorination uses samples that are one million times larger than the ion microprobe. Whole rock (WR) samples from the 53 rocks were analyzed by laser fluorination, giving δ 18O between 9.8‰ and 16.7‰ ( n = 110). Quartz overgrowths in thin sections from 10 rocks were analyzed by ion microprobe and average δ 18O = 29.3 ± 1.0‰ (1SD, n = 161). Given the similarity, on average, of δ 18O for all detrital quartz grains and for all quartz overgrowths, samples with higher δ 18O(WR) values can be shown to have more cement. The quartz cement in the 53 rocks, calculated by mass balance, varies from outlier at 33 vol.% cement. Eolian samples have an average of 11% cement compared to marine samples, which average 4% cement. Two models for quartz cementation have been investigated: high temperature (50-110 °C) formation from ore-forming brines related to Mississippi Valley Type (MVT) mineralization and formation as silcretes at low temperature (10-30 °C). The homogeneity of δ 18O for quartz overgrowths determined by ion microprobe rules out a systematic regional variation of temperature as predicted for MVT brines and there are no other known heating events in these sediments that were never buried to depths >1 km. The data in this study suggest that quartz overgrowths formed as silcretes in the St. Peter Sandstone from meteoric water with δ 18O values of -10

  13. A high-resolution peak fractionation approach for streamlined screening of nuclear-factor-E2-related factor-2 activators in Salvia miltiorrhiza.

    Science.gov (United States)

    Zhang, Hui; Luo, Li-Ping; Song, Hui-Peng; Hao, Hai-Ping; Zhou, Ping; Qi, Lian-Wen; Li, Ping; Chen, Jun

    2014-01-24

    Generation of a high-purity fraction library for efficiently screening active compounds from natural products is challenging because of their chemical diversity and complex matrices. In this work, a strategy combining high-resolution peak fractionation (HRPF) with a cell-based assay was proposed for target screening of bioactive constituents from natural products. In this approach, peak fractionation was conducted under chromatographic conditions optimized for high-resolution separation of the natural product extract. The HRPF approach was automatically performed according to the predefinition of certain peaks based on their retention times from a reference chromatographic profile. The corresponding HRPF database was collected with a parallel mass spectrometer to ensure purity and characterize the structures of compounds in the various fractions. Using this approach, a set of 75 peak fractions on the microgram scale was generated from 4mg of the extract of Salvia miltiorrhiza. After screening by an ARE-luciferase reporter gene assay, 20 diterpene quinones were selected and identified, and 16 of these compounds were reported to possess novel Nrf2 activation activity. Compared with conventional fixed-time interval fractionation, the HRPF approach could significantly improve the efficiency of bioactive compound discovery and facilitate the uncovering of minor active components. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Direct nuclear magnetic resonance identification and quantification of geometric isomers of conjugated linoleic acid in milk lipid fraction without derivatization steps: Overcoming sensitivity and resolution barriers

    International Nuclear Information System (INIS)

    Tsiafoulis, Constantinos G.; Skarlas, Theodore; Tzamaloukas, Ouranios; Miltiadou, Despoina; Gerothanassis, Ioannis P.

    2014-01-01

    Highlights: • The first NMR quantification of four geometric 18:2 CLA isomers has been achieved. • Sensitivity and resolution NMR barriers have been overcome. • Selective suppression and reduced 13 C spectral width have been utilized. • The method is applied in the milk lipid fraction without derivatization steps. • The method is selective, sensitive with very good analytical characteristics. - Abstract: We report the first successful direct and unequivocal identification and quantification of four minor geometric (9-cis, 11-trans) 18:2, (9-trans, 11-cis) 18:2, (9-cis, 11-cis) 18:2 and (9-trans, 11-trans) 18:2 conjugated linoleic acid (CLA) isomers in lipid fractions of lyophilized milk samples with the combined use of 1D 1 H-NMR, 2D 1 H- 1 H TOCSY and 2D 1 H- 13 C HSQC NMR. The significant sensitivity barrier has been successfully overcome under selective suppression of the major resonances, with over 10 4 greater equilibrium magnetization of the -(CH 2 ) n - 1 H spins compared to that of the 1 H spins of the conjugated bonds of the CLA isomers. The resolution barrier has been significantly increased using reduced 13 C spectral width in the 2D 1 H- 13 C HSQC experiment. The assignment was confirmed with spiking experiments with CLA standard compounds and the method does not require any derivatization steps for the lipid fraction. The proposed method is selective, sensitive and compares favorably with the GS-MS method of analysis

  15. Fourier Transform Near Infrared Microspectroscopy, Infrared Chemical Imaging, High-Resolution Nuclear Magnetic Resonance and Fluorescence Microspectroscopy Detection of Single Cancer Cells and Single Viral Particles

    CERN Document Server

    Baianu,I C; Hofmann, N E; Korban, S S; Lozano, P; You, T

    2004-01-01

    Single Cancer Cells from Human tumors are being detected and imaged by Fourier Transform Infrared (FT-IR), Fourier Transform Near Infrared (FT-NIR)Hyperspectral Imaging and Fluorescence Correlation Microspectroscopy. The first FT-NIR chemical, microscopic images of biological systems approaching one micron resolution are here reported. Chemical images obtained by FT-NIR and FT-IR Microspectroscopy are also presented for oil in soybean seeds and somatic embryos under physiological conditions. FT-NIR spectra of oil and proteins were obtained for volumes as small as two cubic microns. Related, HR-NMR analyses of oil contents in somatic embryos as well as 99% accurate calibrations are also presented here with nanoliter precision. Such high-resolution, 400 MHz H-1 NMR analyses allowed the selection of mutagenized embryos with higher oil content (e.g. >~20%) compared to the average levels in non-mutagenized control embryos. Moreover, developmental changes in single soybean seeds and/or somatic embryos may be monito...

  16. Near Infrared Microspectroscopy, Fluorescence Microspectroscopy, Infrared Chemical Imaging and High Resolution Nuclear Magnetic Resonance Analysis of Soybean Seeds, Somatic Embryos and Single Cells

    CERN Document Server

    Baianu, I C; Hofmann, N E; Korban, S S; Lozano, P; You, T; AOCS 94th Meeting, Kansas

    2002-01-01

    Novel methodologies are currently being developed and established for the chemical analysis of soybean seeds, embryos and single cells by Fourier Transform Infrared (FT-IR), Fourier Transform Near Infrared (FT-NIR) Microspectroscopy, Fluorescence and High-Resolution NMR (HR-NMR). The first FT-NIR chemical images of biological systems approaching one micron resolution are presented here. Chemical images obtained by FT-NIR and FT-IR Microspectroscopy are presented for oil in soybean seeds and somatic embryos under physiological conditions. FT-NIR spectra of oil and proteins were obtained for volumes as small as two cubic microns. Related, HR-NMR analyses of oil contents in somatic embryos are also presented here with nanoliter precision. Such 400 MHz 1H NMR analyses allowed the selection of mutagenized embryos with higher oil content (e.g. ~20%) compared to non-mutagenized control embryos. Moreover, developmental changes in single soybean seeds and/or somatic embryos may be monitored by FT-NIR with a precision ...

  17. The bio-PIXE setup on the Debrecen scanning proton microprobe

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Szikszai, Z.; Uzonyi, I.; Simon, A.; Kiss, A.Z.

    2004-01-01

    Complete text of publication follows. Besides the ongoing applications in archeometry, geology, material science and atmospheric aerosol study, in recent years the IBA Group in Debrecen has joined several biological and biomedical research projects. Such studies require the knowledge of accurate quantitative elemental concentrations and distributions in organic, inhomogeneous thin samples on a microscopic scale. In most cases, to carry out quantitative investigations on biomedical samples down to the cell level, the combination of proton induced X-ray emission (PIXE), Rutherford backscattering (RBS) spectrometry and scanning transmission ion microscopy (STIM) analytical methods are used simultaneously. STIM provides information on the density and structure of the sample, PIXE measures the concentration of the inorganic major and trace elements, and finally RBS serves to characterize the organic matrix, to determine the beam dose, and sometimes the sample thickness. The drawback of this combined method is that to evaluate the RBS data the hydrogen to carbon ratio in the sample must be known. The setup developed at the Debrecen microprobe facility [1] is based on the combined application of on-axis STIM and simultaneous PIXE-PIXE analytical techniques. In the PIXE-PIXE method the sample matrix is determined directly by measuring X-rays from all elements in the sample including the light elements such as carbon and oxygen, using two Si(Li) X-ray detectors. In this arrangement an ultra thin windowed Si(Li) X-ray detector serves to characterize the matrix by measuring low energy X-ray lines (0.2-9 keV) while a large area Be-windowed detector is used to detect the medium and high energy X-ray lines (>4 keV). In this way elements with atomic number higher than 5 can be detected simultaneously, reducing both radiation damage of the sample and measurement time. In addition, the knowledge of the hydrogen content of the sample is not needed, since it influences the

  18. High resolution positron Q-value measurements and nuclear structure studies far from the stability line. Progress report, July 1, 1979-June 30, 1980

    International Nuclear Information System (INIS)

    Avignone, F.T. III.

    1980-01-01

    This document represents a progress report and renewal proposal for the contract DEAS 09 79 ER10434 between the USDOE and USC. During the time from 1 July 1979 to 1 March 1980, the large 35% intrinsic Ge detector was purchased and tested, and the new hyperpure Ge detector for positron end-point-energy measurements was designed and fabricated by ORTEC. It was delivered just prior to January 1, 1980. Measurements using this special equipment began in January 1980. During this period, a new effort in the measurement of short nuclear lifetimes was completed, and nuclear structure measurements of 206 Rn nd 208 Rn were completed. The results of these efforts are described in the text. A search for the Post Doctoral Research Associate was started last summer and the position will be filled on or about 1 March 1980. The first experiments to measure positron end-point-energies were proposed to the ORIC scheduling committee, and measurements will begin in March 1980. Theoretical efforts describe accurately the interference of annihilation radiation with positron end-point-energy measurements were begun

  19. Stability issues of high-energy resolution diode type CdTe nuclear radiation detectors in a long-term operation

    CERN Document Server

    Niraula, M; Aoki, T; Tomita, Y; Hatanaka, Y

    2002-01-01

    High-energy resolution diode type CdTe detectors were fabricated by growing an n-type epitaxial layer on high resistivity p-like crystal wafers, and their stability issues during a long-term operation were studied. Room temperature stability of the detectors was not good at low operating biases of around 200 V. However, it could be improved significantly by operating them at higher biases under full depletion conditions. On the other hand, detectors exhibited excellent stability by cooling them slightly below room temperature down to 0 deg. C. The effect of this low level of cooling on detector stability was found to be more significant than that of applying high biases at room temperature. By using the detector type presented here, stable operation could be obtained at moderate operating voltages of around 400 V and with a modest degree of cooling.

  20. Nuclear analytical techniques in medicine

    International Nuclear Information System (INIS)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future

  1. Nuclear analytical techniques in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future.

  2. Ion microprobe analyses of oxygen three-isotope ratios of chondrules from the Sayh al Uhaymir 290 CH chondrite using a multiple-hole disk

    Digital Repository Service at National Institute of Oceanography (India)

    Nakashima, D.; Ushikubo, T.; Gowda, R.N.; Kita, N.T.; Valley, J.W.; Naga, K.

    Author version: Meteorit. Planet. Sci., vol.46(6); 2011; 857-874 Ion microprobe analyses of oxygen three isotope ratios of chondrules from the Sayh al Uhaymir 290 CH chondrite using a multiple-hole disk Daisuke Nakashima 1,2,* , Takayuki Ushikubo...

  3. Verification of a uranium micromass standard using the Eindhoven scanning microprobe

    NARCIS (Netherlands)

    Simons, D.P.L.; Lagerwaard, A.; Mutsaers, P.H.A.; Voigt, de M.J.A.

    1999-01-01

    Analysis of dust samples from uranium enrichment facilities is focused on the detection and analysis of uranium-containing particles. A chemical and isotopic analysis of individual particles from dust samples is thought to be an effective analytical tool to check the absence of nuclear-weapon

  4. Development of a new measurement method for fast breeder reactor fuel burnup using a shielded ion microprobe analyzer

    International Nuclear Information System (INIS)

    Mizuno, M.; Enokido, Y.; Itaki, T.; Kono, K.; Unno, I.; Yamanouchi, S.

    1985-01-01

    A new method of burnup measurement using a shielded ion microprobe analyzer (SIMA) has been developed. The method is based on the isotope analysis of uranium, plutonium, and fission products in irradiated mixed oxide fuel by means of secondary ion mass spectrometry (SIMS). Fourteen samples irradiated in the Japanese experimental fast reactor JOYO were examined. The maximum local burnup of JOYO MK-I core fuels was about5.1 at. %. The axial burnup distribution of the fuel pin was in good agreement with that of the sibling pin in the same subassembly, measured by surface ionization mass spectrometry, which requires the chemical separation of fission products and heavy metals. The new method facilitates the rapid and accurate measurement of fast breeder reactor fuel burnup without human radiation exposure during sample preparation and analysis

  5. Review on the application of electron microprobe chemical dating method in the age research of uranium/pitchblende

    International Nuclear Information System (INIS)

    Ge Xiangkun; Qin Mingkuan; Fan Guang

    2011-01-01

    Different micro dating methods have been developed in recent years, the advantages and disadvantages are simply introduced at first. The recent development of electron microprobe chemical dating method in the age research of uraninite/pitchblende and the used analytical conditions by the precurser are presented in detail by stages. Finally, the application foreground of this method in the age research of uraninite/pitchblende and the possible problems are systematically investigated and discussed. It is believed that this method will play a big role in the age research of uranium minerals, especially in the micro dating research of tiny uranium minerals (φ < 10 μm) and uranium micro-ores of multi-stage. (authors)

  6. A scanning proton microprobe study of stinging emergences from the leaf of the common stinging nettle urtica dioica l.

    Science.gov (United States)

    Hughes, N. P.; Perry, C. C.; Williams, R. J. P.; Watt, F.; Grime, G. W.

    1988-03-01

    Proton-induced X-ray emission (PIXE) combined with the Oxford scanning proton microprobe (SPM) was used to investigate the abundance and spatial distribution of inorganic elements in mineralising stinging emergences from the leaf of the Common Stinging Nettle, Urtica dioica L. Elemental maps and point analytical data were collected for emergences at two stages of maturity. In all emergences calcium and silicon were spatially organised and present at high concentration. The inorganic elements K, P, S and Mn were also spatially organised during mineralisation, but at maturity these elements were present only at background levels and then showed no specific localisation. The observed changes in the inorganic content of the emergences are obviously related to the mineralisation processes. The possible biochemical significance of the distribution of the elements is discussed.

  7. Nuclear safety in France

    International Nuclear Information System (INIS)

    Servant, J.

    1979-12-01

    The main areas of nuclear safety are considered in this paper, recalling the laws and resolutions in force and also the appropriate authority in each case. The following topics are reviewed: radiological protection, protection of workers, measures to be taken in case of an accident, radioactive effluents, impact on the environment of non-nuclear pollution, nuclear plant safety, protection against malicious acts, control and safeguard of nuclear materials, radioisotopes, transport of radioactive substances, naval propulsion, waste management, nuclear plant decommissioning and export of nuclear equipment and materials. Finally, the author describes the role of the general Secretariat of the Interdepartmental Committee on Nuclear Safety

  8. San Francisco Estuary Striped Bass Migration History Determined by Electron-microprobe Analysis of Otolith Sr/Ca Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Ostrach, D J; Phillis, C C; Weber, P K; Ingram, B L; Zinkl, J G

    2004-09-17

    Habitat use has been shown to be an important factor in the bioaccumulation of contaminants in striped bass. This study examines migration in striped bass as part of a larger study investigating bioaccumulation and maternal transfer of xenobiotics to progeny in the San Francisco Estuary system. Habitat use, residence time and spawning migration over the life of females (n = 23) was studied. Female striped bass were collected between Knights Landing and Colusa on the Sacramento River during the spawning runs of 1999 and 2001. Otoliths were removed, processed and aged via otolith microstructure. Subsequently, otoliths were analyzed for strontium/calcium (Sr/Ca) ratio using an electron-microprobe to measure salinity exposure and to distinguish freshwater, estuary, and marine habitat use. Salinity exposure during the last year before capture was examined more closely for comparison of habitat use by the maternal parent to contaminant burden transferred to progeny. Results were selectively confirmed by ion microprobe analyses for habitat use. The Sr/Ca data demonstrate a wide range of migratory patterns. Age of initial ocean entry differs among individuals before returning to freshwater, presumably to spawn. Some fish reside in freshwater year-round, while others return to more saline habitats and make periodic migrations to freshwater. Frequency of habitat shifts and residence times differs among fish, as well as over the lifetime of individual fish. While at least one fish spent its final year in freshwater, the majority of spawning fish spent their final year in elevated salinity. However, not all fish migrated to freshwater to spawn in the previous year. Results from this investigation concerning migration history in striped bass can be combined with contaminant and histological developmental analyses to better understand the bioaccumulation of contaminants and the subsequent effects they and habitat use have on fish populations in the San Francisco Estuary system.

  9. Planktonic foraminiferal oxygen isotope analysis by ion microprobe technique suggests warm tropical sea surface temperatures during the Early Paleogene

    Science.gov (United States)

    Kozdon, Reinhard; Kelly, D. Clay; Kita, Noriko T.; Fournelle, John H.; Valley, John W.

    2011-09-01

    Cool tropical sea surface temperatures (SSTs) are reported for warm Paleogene greenhouse climates based on the δ18O of planktonic foraminiferal tests. These results are difficult to reconcile with models of greenhouse gas-forced climate. It has been suggested that this "cool tropics paradox" arises from postdepositional alteration of foraminiferal calcite, yielding erroneously high δ18O values. Recrystallization of foraminiferal tests is cryptic and difficult to quantify, and the compilation of robust δ18O records from moderately altered material remains challenging. Scanning electron microscopy of planktonic foraminiferal chamber-wall cross sections reveals that the basal area of muricae, pustular outgrowths on the chamber walls of species belonging to the genus Morozovella, contain no mural pores and may be less susceptible to postdepositional alteration. We analyzed the δ18O in muricae bases of morozovellids from the central Pacific (Ocean Drilling Program Site 865) by ion microprobe using 10 μm pits with an analytical reproducibility of ±0.34‰ (2 standard deviations). In situ measurements of δ18O in these domains yield consistently lower values than those published for conventional multispecimen analyses. Assuming that the original δ18O is largely preserved in the basal areas of muricae, this new δ18O record indicates Early Paleogene (˜49-56 Ma) tropical SSTs in the central Pacific were 4°-8°C higher than inferred from the previously published δ18O record and that SSTs reached at least ˜33°C during the Paleocene-Eocene thermal maximum. This study demonstrates the utility of ion microprobe analysis for generating more reliable paleoclimate records from moderately altered foraminiferal tests preserved in deep-sea sediments.

  10. Analysis of the unresolved organic fraction in atmospheric aerosols with ultrahigh-resolution mass spectrometry and nuclear magnetic resonance spectroscopy: organosulfates as photochemical smog constituents.

    Science.gov (United States)

    Schmitt-Kopplin, Philippe; Gelencsér, Andras; Dabek-Zlotorzynska, Ewa; Kiss, Gyula; Hertkorn, Norbert; Harir, Mourad; Hong, Yang; Gebefügi, Istvan

    2010-10-01

    Complementary molecular and atomic signatures obtained from Fourier transform ion cyclotron resonance (FTICR) mass spectra and NMR spectra provided unequivocal attribution of CHO, CHNO, CHOS, and CHNOS molecular series in secondary organic aerosols (SOA) and high-resolution definition of carbon chemical environments. Sulfate esters were confirmed as major players in SOA formation and as major constituents of its water-soluble fraction (WSOC). Elevated concentrations of SO(2), sulfate, and photochemical activity were shown to increase the proportion of SOA sulfur-containing compounds. Sulfonation of CHO precursors by means of heterogeneous reactions between carbonyl derivatives and sulfuric acid in gas-phase photoreactions was proposed as a likely formation mechanism of CHOS molecules. In addition, photochemistry induced oligomerization processes of CHOS molecules. Methylesters found in methanolic extracts of a SOA subjected to strong photochemical exposure were considered secondary products derived from sulfate esters by methanolysis. The relative abundance of nitrogen-containing compounds (CHNO and CHNOS series) appeared rather dependent on local effects such as biomass burning. Extensive aliphatic branching and disruption of extended NMR spin-systems by carbonyl derivatives and other heteroatoms were the most significant structural motifs in SOA. The presence of heteroatoms in elevated oxidation states suggests a clearly different SOA formation trajectory in comparison with established terrestrial and aqueous natural organic matter.

  11. An Arabidopsis introgression zone studied at high spatio-temporal resolution: interglacial and multiple genetic contact exemplified using whole nuclear and plastid genomes.

    Science.gov (United States)

    Hohmann, Nora; Koch, Marcus A

    2017-10-23

    Gene flow between species, across ploidal levels, and even between evolutionary lineages is a common phenomenon in the genus Arabidopsis. However, apart from two genetically fully stabilized allotetraploid species that have been investigated in detail, the extent and temporal dynamics of hybridization are not well understood. An introgression zone, with tetraploid A. arenosa introgressing into A. lyrata subsp. petraea in the Eastern Austrian Forealps and subsequent expansion towards pannonical lowlands, was described previously based on morphological observations as well as molecular data using microsatellite and plastid DNA markers. Here we investigate the spatio-temporal context of this suture zone, making use of the potential of next-generation sequencing and whole-genome data. By utilizing a combination of nuclear and plastid genomic data, the extent, direction and temporal dynamics of gene flow are elucidated in detail and Late Pleistocene evolutionary processes are resolved. Analysis of nuclear genomic data significantly recognizes the clinal structure of the introgression zone, but also reveals that hybridization and introgression is more common and substantial than previously thought. Also tetraploid A. lyrata and A. arenosa subsp. borbasii from outside the previously defined suture zone show genomic signals of past introgression. A. lyrata is shown to serve usually as the maternal parent in these hybridizations, but one exception is identified from plastome-based phylogenetic reconstruction. Using plastid phylogenomics with secondary time calibration, the origin of A. lyrata and A. arenosa lineages is pre-dating the last three glaciation complexes (approx. 550,000 years ago). Hybridization and introgression followed during the last two glacial-interglacial periods (since approx. 300,000 years ago) with later secondary contact at the northern and southern border of the introgression zone during the Holocene. Footprints of adaptive introgression in the

  12. Metabonomic profiling of renal cell carcinoma: High-resolution proton nuclear magnetic resonance spectroscopy of human serum with multivariate data analysis

    International Nuclear Information System (INIS)

    Gao Hongchang; Dong Baijun; Liu Xia; Xuan Hanqing; Huang Yiran; Lin Donghai

    2008-01-01

    Metabonomic profiling using proton nuclear magnetic resonance ( 1 H NMR) spectroscopy and multivariate data analysis of human serum samples was used to characterize metabolic profiles in renal cell carcinoma (RCC). We found distinct, easily detectable differences between (a) RCC patients and healthy humans, (b) RCC patients with metastases and without metastases, and (c) RCC patients before and after nephrectomy. Compared to healthy human serum, RCC serum had higher levels of lipid (mainly very low-density lipoproteins), isoleucine, leucine, lactate, alanine, N-acetylglycoproteins, pyruvate, glycerol, and unsaturated lipid, together with lower levels of acetoacetate, glutamine, phosphatidylcholine/choline, trimethylamine-N-oxide, and glucose. This pattern was somewhat reversed after nephrectomy. Altered metabolite concentrations are most likely the result of the cells switching to glycolysis to maintain energy homeostasis following the loss of ATP caused by impaired TCA cycle in RCC. Serum NMR spectra combined with principal component analysis techniques offer an efficient, convenient way of depicting tumour biochemistry and stratifying tumours under different pathophysiological conditions. It may be able to assist early diagnosis and postoperative surveillance of human malignant diseases using single blood samples

  13. A report on high-level nuclear transportation: Prepared pursuant to assembly concurrent Resolution No. 8 of the 1987 Nevada Legislature

    International Nuclear Information System (INIS)

    1988-12-01

    The report is divided into three major sections, each of which addresses one of three directives cited above. Section 1.0 provides a review of DOE's statutory requirements, its repository transportation program and plans, the major policy, programmatic, technical and institutional issues and specific areas of concern for the State of Nevada. Section 2.0 contains a description of the current federal, state and tribal transportation regulatory environment within which nuclear waste is shipped and a discussion of regulatory issues which must be resolved in order for the State to minimize risks and adverse impacts to its citizens. Among other issues, this section addresses emergency management, liability for accidents, state permitting and fees, and consistency of State and local regulation with federal law. Section 3.0 contains the NWPO plan for the study and management of repository-related transporation. The plan addresses four areas, including policy and program management, regulatory studies, technical reviews and studies and institutional relationships. A fourth section provides recommendations for consideration by State and local officials which would assist the State in meeting the objectives of the plan

  14. Biologically relevant conformational features of linear and cyclic proteolipid protein (PLP) peptide analogues obtained by high-resolution nuclear magnetic resonance and molecular dynamics

    Science.gov (United States)

    Kordopati, Golfo G.; Tzoupis, Haralambos; Troganis, Anastassios N.; Tsivgoulis, Gerasimos M.; Golic Grdadolnik, Simona; Simal, Carmen; Tselios, Theodore V.

    2017-09-01

    Proteolipid protein (PLP) is one of the main proteins of myelin sheath that are destroyed during the progress of multiple sclerosis (MS). The immunodominant PLP139-151 epitope is known to induce experimental autoimmune encephalomyelitis (EAE, animal model of MS), wherein residues 144 and 147 are recognized by T cell receptor (TCR) during the formation of trimolecular complex with peptide-antigen and major histocompability complex. The conformational behavior of linear and cyclic peptide analogues of PLP, namely PLP139-151 and cyclic (139-151) (L144, R147) PLP139-151, have been studied in solution by means of nuclear magnetic resonance (NMR) methods in combination with unrestrained molecular dynamics simulations. The results indicate that the side chains of mutated amino acids in the cyclic analogue have different spatial orientation compared with the corresponding side chains of the linear analogue, which can lead to reduced affinity to TCR. NMR experiments combined with theoretical calculations pave the way for the design and synthesis of potent restricted peptides of immunodominant PLP139-151 epitope as well as non peptide mimetics that rises as an ultimate goal.

  15. Ion microprobe (SHRIMP) dating of detrital zircon grains from quartzites of the Eckergneiss Complex, Harz Mountains (Germany): implications for the provenance and the geological history

    Science.gov (United States)

    Geisler, Thorsten; Vinx, Roland; Martin-Gombojav, Nergui; Pidgeon, Robert T.

    2005-07-01

    The Eckergneiss Complex (EGC) is a geologically unique medium- to high-grade metamorphic unit within the Rhenohercynian domain of the Mid-European Variscides. A previously, poorly defined conventional lower U Pb intercept age of about 560 Ma from detrital zircons of metasedimentary rocks has led to speculations about an East Avalonian affinity of the EGC. In order to unravel the provenance and to constrain the age of the sediment protolith, we carried out sensitive high-resolution ion microprobe U Pb analyses on detrital zircons from five different EGC quartzite occurrences. The obtained age spectrum indicates a SW Baltica provenance of the detritus. Sveconorwegian ages between 0.9 1.2 Ga are particularly well represented by analyses from metamorphic recrystallization/alteration zones penetrating into igneous zircon. Cadomian (Pan-African) ages, which might reflect a metamorphic event, could not be substantiated. Instead, zircons of igneous origin yielded concordant Lower Devonian and Silurian ages of 410±10, 419±10, and 436±6 Ma (1σ), implying that sedimentation of the EG protolith must have taken place after 410±10 Ma. The lower age limit of the EGC metamorphism is constrained by 295 Ma intrusion ages of the adjacent, nonmetamorphosed Harzburg Gabbronorite and Brocken Granite. Sedimentation and metamorphism must thus have taken place between about 410 Ma and 295 Ma. Given that this time span coincides with most of the sedimentation within the virtually nonmetamorphosed (lowest grade) Rhenohercynian in the Harz Mountains, including the direct vicinity of the EGC, along with the high-grade metamorphism, the EGC can hardly be seen as uplifted local basement. A possible candidate for the root region is an easterly, concealed marginal segment of the Rhenohercynian domain of the Variscides, which is tectonically overridden and suppressed by the Mid-German Crystalline Rise during continent collision. However, based on the concept of strike-slip movement of Variscan

  16. Submicrovolt resolution X-ray monochromators

    International Nuclear Information System (INIS)

    Trammell, G.T.; Hannon, J.P.

    1984-01-01

    Two methods are available to obtain monochromatic x-radiation from a white source: wavelength selection and frequency selection. The resolution of wavelength selection methods is limited to 1-10 MeV in the E = 10 KeV range. To exceed this resolution frequency selection methods based on nuclear resonance scattering can be used. Devices which give strong nuclear resonance reflections but weak electronic reflections are candidates for components of frequency selection monochromates. Some examples are discussed

  17. Metabolic fingerprinting of joint tissue of collagen-induced arthritis (CIA) rat: In vitro, high resolution NMR (nuclear magnetic resonance) spectroscopy based analysis.

    Science.gov (United States)

    Srivastava, Niraj Kumar; Sharma, Shikha; Sharma, Rajkumar; Sinha, Neeraj; Mandal, Sudhir Kumar; Sharma, Deepak

    2018-01-01

    Rheumatoid arthritis (RA) is a systemic autoimmune disease whose major characteristics persistent joint inflammation that results in joint destruction and failure of the function. Collagen-induced arthritis (CIA) rat is an autoimmune disease model and in many ways shares features with RA. The CIA is associated with systemic manifestations, including alterations in the metabolism. Nuclear magnetic resonance (NMR) spectroscopy-based metabolomics has been successfully applied to the perchloric acid extract of the joint tissue of CIA rat and control rat for the analysis of aqueous metabolites. GPC (Glycerophosphocholine), carnitine, acetate, and creatinine were important discriminators of CIA rats as compared to control rats. Level of lactate (significance; p = 0.004), alanine (p = 0.025), BCA (Branched-chain amino acids) (p = 0.006) and creatinine (p = 0.023) was significantly higher in CIA rats as compared to control rats. Choline (p = 0.038) and GPC (p = 0.009) were significantly reduced in CIA rats as compared to control rats. Choline to GPC correlation was good and negative (Pearson correlation = -0.63) for CIA rats as well as for control rats (Pearson correlation = -0.79). All these analyses collectively considered as metabolic fingerprinting of the joint tissue of CIA rat as compared to control rat. The metabolic fingerprinting of joint tissue of CIA rats was different as compared to control rats. The metabolic fingerprinting reflects inflammatory disease activity in CIA rats with synovitis, demonstrating that underlying inflammatory process drives significant changes in metabolism that can be measured in the joint tissue. Therefore, the outcome of this study may be helpful for understanding the mechanism of metabolic processes in RA. This may be also helpful for the development of advanced diagnostic methods and therapy for RA.

  18. Exploring the structure of fucosylated chondroitin sulfate through bottom-up nuclear magnetic resonance and electrospray ionization-high-resolution mass spectrometry approaches.

    Science.gov (United States)

    Santos, Gustavo Rc; Porto, Ana Co; Soares, Paulo Ag; Vilanova, Eduardo; Mourão, Paulo As

    2017-07-01

    Fucosylated chondroitin sulfate (FCS) from sea cucumbers is composed of a chondroitin sulfate (CS) central core and branches of sulfated fucose. The structure of this complex glycosaminoglycan is usually investigated via nuclear magnetic resonance (NMR) analyses of the intact molecule, ergo through a top-down approach, which often yield spectra with intricate sets of signals. Here we employed a bottom-up approach to analyze the FCSs from the sea cucumbers Isostichopus badionotus and Ludwigothurea grisea from their basic constituents, viz. CS cores and sulfated fucose branches, obtained via systematic fragmentation through mild acid hydrolysis. Oligosaccharides derived from the central CS core were analyzed via NMR spectroscopy and the disaccharides produced using chondroitin sulfate lyase via SAX-HPLC. The CS cores from the two species were similar, showing only slight differences in the proportions of 4- or 6-monosulfated and 4,6-disulfated β-d-GalNAc. Sulfated fucose units released from the FCSs were analyzed via NMR and ESI-HRMS spectroscopies. The fucose units from each species presented extensive qualitative differences, but quantitative assessments of these units were hindered, mostly because of their extensive desulfation during the hydrolysis. The bottom-up analysis performed here has proved useful to explore the structure of FCS through a sum-of-the-parts approach in a qualitative manner. We further demonstrate that under specific acidification conditions particular fucose branches can be removed preferentially from FCS. Preparation of derivatives enriched with particular fucose branches could be useful for studies on "structure vs. biological function" of FCS. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Gap Resolution

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-25

    Gap Resolution is a software package that was developed to improve Newbler genome assemblies by automating the closure of sequence gaps caused by repetitive regions in the DNA. This is done by performing the follow steps:1) Identify and distribute the data for each gap in sub-projects. 2) Assemble the data associated with each sub-project using a secondary assembler, such as Newbler or PGA. 3) Determine if any gaps are closed after reassembly, and either design fakes (consensus of closed gap) for those that closed or lab experiments for those that require additional data. The software requires as input a genome assembly produce by the Newbler assembler provided by Roche and 454 data containing paired-end reads.

  20. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    International Nuclear Information System (INIS)

    Ponomarev, A.G.; Melnik, K.I.; Miroshnichenko, V.I.; Storizhko, V.E.; Sulkio-Cleff, B.

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 μm with a beam current of ∼100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and second- and third-order parasitic aberrations resulting from distortions of the quadrupole lens symmetry. Therefore probe-forming systems with triplets and quadruplets of magnetic quadrupole lenses have a lower theoretical spatial resolution limit which is restricted mainly by intrinsic spherical third-order aberrations in state-of-the-art microprobes