  1. A Rough Guide to Metabolite Identification Using High Resolution Liquid Chromatography Mass Spectrometry in Metabolomic Profiling in Metazoans

    Directory of Open Access Journals (Sweden)

    David G Watson

    2013-01-01

    Full Text Available Compound identification in mass spectrometry based metabolomics can be a problem but sometimes the problem seems to be presented in an over complicated way. The current review focuses on metazoans where the range of metabolites is more restricted than for example in plants. The focus is on liquid chromatography with high resolution mass spectrometry where it is proposed that most of the problems in compound identification relate to structural isomers rather than to isobaric compounds. Thus many of the problems faced relate to separation of isomers, which is usually required even if fragmentation is used to support structural identification. Many papers report the use of MS/MS or MS2 as an adjunct to the identification of known metabolites but there a few examples in metabolomics studies of metazoans of complete structure elucidation of novel metabolites or metabolites where no authentic standards are available for comparison.

  2. Development and Validation of Liquid Chromatography- Mass ...

    African Journals Online (AJOL)

    HP

    Method: A novel liquid chromatography–tandem mass spectrometry method for the quantitative determination of naproxen in human K2-EDTA plasma in negative ion mode was employed ..... Practice and Applications of Bio-analytical Method.

  3. Liquid chromatography - mass spectrometry analysis of pharmaceuticals

    International Nuclear Information System (INIS)

    Macasek, F.

    2003-01-01

    The drugs represent mostly non-volatile and thermally labile solutes, often available only in small amounts like it is in case of radiopharmaceuticals. Therefor, the favourable separation techniques for such compounds are HPLC, capillary electrophoresis and also TLC 1. Liquid chromatography with mass spectrometric detector (LC/MS) is especially powerful for their microanalysis. Mass spectrometry separating the ions in high vacuum was presumably used as detector for gas chromatography effluent but the on-line coupling with liquid eluant flow 0.1-1 mL/min is far more challenging. New types of ion sources were constructed for simultaneous removal of solvent and ionisation of solutes at atmospheric pressure (API). At present, a relatively wide choice of successfully designed commercial equipment is available either for small organic molecules and larger biomolecules (Perkin-Elmer, Agilent, Jeol, Bruker Daltonics, ThermoQuest, Shimadzu). The features of the LC/MS systems are presented. LC/MS as a new quality control tool for [F-18]fluorodeoxyglucose (FDG) radiopharmaceutical, which has became the most spread radiopharmaceutical for positron emission tomography (PET), was proposed. Other applications of the LC/MS are reviewed. (author)

  4. Cortisol production rates measured by liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Esteban, N.V.; Yergey, A.L.

    1990-01-01

    Cortisol production rates (FPRs) in physiologic and pathologic states in humans have been investigated over the past 30 years. However, there has been conflicting evidence concerning the validity of the currently accepted value of FPRs in humans (12 to 15 mg/m2/d) as determined by radiotracer methodology. The present study reviews previous methods proposed for the measurement of FPRs in humans and discusses the applications of the first method for the direct determination of 24-hour plasma FPRs during continuous administration of a stable isotope, using a thermospray high-pressure liquid chromatography-mass spectrometry technique. The technique is fast, sensitive, and, unlike gas chromatography-mass spectrometry methods, does not require derivatization, allowing on-line detection and quantification of plasma cortisol after a simple extraction procedure. The results of determination of plasma FPRs by stable tracer/mass spectrometry are directly in units of mass/time and, unlike radiotracer methods, are independent of any determination of volume of distribution or cortisol concentration. Our methodology offers distinct advantages over radiotracer techniques in simplicity and reliability since only single measurements of isotope ratios are required. The technique was validated in adrenalectomized patients. Circadian variations in daily FRPs were observed in normal volunteers, and, to date, results suggest a lower FRP in normal children and adults than previously believed. 88 references

  5. Liquid chromatography-mass spectrometry in forensic toxicology.

    Science.gov (United States)

    Van Bocxlaer, J F; Clauwaert, K M; Lambert, W E; Deforce, D L; Van den Eeckhout, E G; De Leenheer, A P

    2000-01-01

    Liquid chromatography-mass spectrometry has evolved from a topic of mainly research interest into a routinely usable tool in various application fields. With the advent of new ionization approaches, especially atmospheric pressure, the technique has established itself firmly in many areas of research. Although many applications prove that LC-MS is a valuable complementary analytical tool to GC-MS and has the potential to largely extend the application field of mass spectrometry to hitherto "MS-phobic" molecules, we must recognize that the use of LC-MS in forensic toxicology remains relatively rare. This rarity is all the more surprising because forensic toxicologists find themselves often confronted with the daunting task of actually searching for evidence materials on a scientific basis without any indication of the direction in which to search. Through the years, mass spectrometry, mainly in the GC-MS form, has gained a leading role in the way such quandaries are tackled. The advent of robust, bioanalytically compatible combinations of liquid chromatographic separation with mass spectrometric detection really opens new perspectives in terms of mass spectrometric identification of difficult molecules (e.g., polar metabolites) or biopolymers with toxicological relevance, high throughput, and versatility. Of course, analytical toxicologists are generally mass spectrometry users rather than mass spectrometrists, and this difference certainly explains the slow start of LC-MS in this field. Nevertheless, some valuable applications have been published, and it seems that the introduction of the more universal atmospheric pressure ionization interfaces really has boosted interests. This review presents an overview of what has been realized in forensic toxicological LC-MS. After a short introduction into LC-MS interfacing operational characteristics (or limitations), it covers applications that range from illicit drugs to often abused prescription medicines and some

  6. Characterisation of uremic "Middle molecular"fractions by gas chromatography mass spectrometry, isotachophoresis, and liquid chromatography

    NARCIS (Netherlands)

    Schoots, A.C.; Mikkers, F.E.P.; Claessens, H.A.; Smet, de R.; Landschoot, van N.; Ringoir, S.M.G.

    1982-01-01

    Uremic ultrafiltrates (and normal serum, for comparison) were fractionated by means of gel filtration. The collected fractions were further investigated by combined analytical techniques: "high- performance" liquid chromatography, gas chromatography, mass spectrometry, and isotachophoresis.

  7. Characterization of the designer drug deschloroketamine (2-methylamino-2-phenylcyclohexanone) by gas chromatography/mass spectrometry, liquid chromatography/high-resolution mass spectrometry, multistage mass spectrometry, and nuclear magnetic resonance.

    Science.gov (United States)

    Frison, Giampietro; Zamengo, Luca; Zancanaro, Flavio; Tisato, Francesco; Traldi, Pietro

    2016-01-15

    Clinical and forensic toxicology laboratories are challenged every day by the analytical aspects of the new psychoactive substances phenomenon. In this study we describe the analytical characterization of a new ketamine derivative, deschloroketamine (2-methylamino-2-phenylcyclohexanone), contained in seized powders. The analytical techniques employed include gas chromatography/mass spectrometry (GC/MS), liquid chromatography/electrospray ionization coupled with Orbitrap high-resolution/MS (LC/ESI-HRMS), multistage MS (ESI-MS(n)), and NMR. The LC/ESI-HRMS analyses consisted of accurate mass measurements of MH(+) ions in full-scan mode; comparison of experimental and calculated MH(+) isotopic patterns; and examination of the isotopic fine structure (IFS) of the M + 1, M + 2, M + 3 isotopic peaks relative to the monoisotopic M + 0 peak. The collision-induced product ions of the MH(+) ions were studied by both HRMS and MS(n). (1)H and (13)C NMR measurements were carried out to confirm the chemical structure of the analyte. The EI mass spectra obtained by GC/MS analysis showed the presence of molecular ions at m/z 203, and main fragment ions at m/z 175, 174, 160, 147, 146, and 132. The application of LC/ESI-HRMS allowed us to obtain: the accurate mass of deschloroketamine MH(+) ions with a mass accuracy of 1.47 ppm; fully superimposable experimental and calculated MH(+) isotopic patterns, with a relative isotopic abundance value of 3.69 %; and the IFS of the M + 1, M + 2, M + 3 isotopic peaks completely in accordance with theoretical values. Examination of the product ions of MH(+), as well as the study of both (1)H and (13)C NMR spectra, enabled the full characterization of the molecular structure of deschloroketamine. The combination of the employed analytical techniques allowed the characterization of the seized psychoactive substance, in spite of the lack of a reference standard. Deschloroketamine is a ketamine analogue considered to be

  8. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion

  9. Determination of chlormequat in pears by liquid chromatography/mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    2000-01-01

    A straightforward and reliable method was developed for the determination of chlormequat in pears by liquid chromatography/mass spectrometry (LC/MS). Water and methanol were compared as extraction solvents. Because no significant differences in extraction efficiency or repeatability were found,

  10. Column liquid chromatography- mass spectrometry: selected techniques in environmental applications for polar pesticides and related compounds.

    NARCIS (Netherlands)

    Slobodnik, J.; van Baar, B.L.M.; Brinkman, U.A.T.

    1995-01-01

    A review covering the field of environmental applications of liquid chromatography-mass spectrometry (LC-MS) is presented. Recent developments and advances are discussed with emphasis on the presently popular thermospray, particle beam and atmospheric pressure ionisation interfaces. Each interface

  11. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  12. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Campbell, J.A.; Lerner, B.D.; Bean, R.M.; Grant, K.E.; Lucke, R.B.; Mong, G.M.; Clauss, S.A.

    1994-08-01

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids

  13. Metabolite Extraction from Saccharomyces cerevisiae for Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Rosebrock, Adam P; Caudy, Amy A

    2017-09-01

    Prior to mass spectrometric analysis, cellular small molecules must be extracted and separated from interfering components such as salts and culture medium. To ensure minimal perturbation of metabolism, yeast cells grown in liquid culture are rapidly harvested by filtration as described here. Simultaneous quenching of metabolism and extraction is afforded by immediate immersion in low-temperature organic solvent. Samples prepared using this method are suitable for a range of downstream liquid chromatography-mass spectrometry analyses and are stable in solvent for >1 yr at -80°C. © 2017 Cold Spring Harbor Laboratory Press.

  14. Urinary metabonomics study in a rat model in response to protein-energy malnutrition by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wu, Zeming; Li, Min; Zhao, Chunxia; Zhou, Jia; Chang, Yuwei; Li, Xiang; Gao, Peng; Lu, Xin; Li, Yousheng; Xu, Guowang

    2010-11-01

    Systematic studies were performed on the biological perturbations in metabolic phenotype responding to protein-energy malnutrition through global metabolic profiling analysis, in combination with pattern recognition. The malnutrition rat model was established through five weeks of strict diet restriction, and the metabonome data obtained from gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) were integrated to approximate the comprehensive metabolic signature. Principal component analysis and orthogonal projection to latent structure analysis were used for the classification of metabolic phenotypes and discovery of differentiating metabolites. The perturbations in the urine profiles of malnourished rats were marked by higher levels of creatine, threitol, pyroglutamic acid, gluconic acid and kynurenic acid, as well as decreased levels of succinic acid, cis-aconitic acid, citric acid, isocitric acid, threonic acid, trimethylglycine, N-methylnicotinic acid and uric acid. The alterations in these metabolites were associated with perturbations in energy metabolism, carbohydrate, amino acid, and fatty acid metabolism, purine metabolism, cofactor and vitamin metabolism, in response to protein and energy malnutrition. Our findings show the integration of GC-MS and LC-MS techniques for untargeted metabolic profiling analysis was promising for nutriology.

  15. Current practice of liquid chromatography-mass spectrometry in metabolomics and metabonomics.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Plumb, Robert S; Wilson, Ian D

    2014-01-01

    Based on publication and citation numbers liquid chromatography (LC-MS) has become the major analytical technology in the field of global metabolite profiling. This dominance reflects significant investments from both the research community and instrument manufacturers. Here an overview of the approaches taken for LC-MS-based metabolomics research is given, describing critical steps in the realisation of such studies: study design and its needs, specific technological problems to be addressed and major obstacles in data treatment and biomarker identification. The current state of the art for LC-MS-based analysis in metabonomics/metabolomics is described including recent developments in liquid chromatography, mass spectrometry and data treatment as these are applied in metabolomics underlining the challenges, limitations and prospects for metabolomics research. Examples of the application of metabolite profiling in the life sciences focusing on disease biomarker discovery are highlighted. In addition, new developments and future prospects are described. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Comparative urine analysis by liquid chromatography-mass spectrometry and multivariate statistics : Method development, evaluation, and application to proteinuria

    NARCIS (Netherlands)

    Kemperman, Ramses F. J.; Horvatovich, Peter L.; Hoekman, Berend; Reijmers, Theo H.; Muskiet, Frits A. J.; Bischoff, Rainer

    2007-01-01

    We describe a platform for the comparative profiling of urine using reversed-phase liquid chromatography-mass spectrometry (LC-MS) and multivariate statistical data analysis. Urinary compounds were separated by gradient elution and subsequently detected by electrospray Ion-Trap MS. The lower limit

  17. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory

  18. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts

    NARCIS (Netherlands)

    de Jong, C.F.; Derks, R.J.E.; Bruyneel, B.; Niessen, W.M.A.; Irth, H.

    2006-01-01

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the

  19. Analysis of CYP3A inhibitory components of star fruit (Averrhoa carambola L.) using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hosoi, Shinzo; Shimizu, Eri; Arimori, Kazuhiko; Okumura, Manabu; Hidaka, Muneaki; Yamada, Mitsuko; Sakushima, Akiyo

    2008-07-01

    In this study, we analyzed the CYP3A inhibitory components of star fruit Averrhoa carambola L., using liquid chromatography-mass spectrometry (LC-MS). The stereoisomer of procyanidin B1 and B2 and/or the trimer consisting of catechin and/or epicatechin were suggested to be potent inhibitory components.

  20. Liquid chromatography/mass spectrometric determination of patulin in apple juice using atmospheric pressure photoionization.

    Science.gov (United States)

    Takino, Masahiko; Daishima, Shigeki; Nakahara, Taketoshi

    2003-01-01

    This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) technique for the liquid chromatography/mass spectrometric (LC/MS) determination of patulin in clear apple juice. A column switching technique for on-line extraction of clear apple juice was developed. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for both APCI and APPI. The results indicated that APPI provides lower chemical noise and signal suppression in comparison with APCI. The linear range for patulin in apple juice (correlation coefficient >0.999) was 0.2-100 ng mL(-1). Mean recoveries of patulin in three apple juices ranged from 94.5 to 103.2%, and the limit of detection (S/N = 3), repeatability and reproducibility were 1.03-1.50 ng mL(-1), 3.9-5.1% and 7.3-8.2%, respectively. The total analysis time was 10.0 min. Copyright 2003 John Wiley & Sons, Ltd.

  1. Enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Hasegawa, Takashi; Takahashi, Kazunaga; Fukiwake, Tomohide; Saijo, Masaaki; Motoki, Yuji

    2013-01-01

    We developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens. L- and D-DOPA were ultrasonically extracted with 1% formic acid aqueous solution. The isolated extracts were analyzed by LC/MS using a Crownpak CR (-) column at 30℃. The mass spectrometer was operated in the positive mode of electrospray ionization, and the mobile phase was aqueous formic acid (pH 2.0). L-DOPA-ring-d3 was used as an internal standard. The method was validated for a dietary supplement spiked with L- and D-DOPA at 50 and 500 μg/g, respectively, and the recoveries of the DOPA enantiomers were between 97.5% and 101.3%. Relative standard deviation values of repeatability and intermediate precision were less than 7%. The method was applied to 14 dietary supplements. L-DOPA was detected in these supplements in the range of 0.88-12.8 mg/unit. D-DOPA was not detected.

  2. Current role of liquid chromatography-mass spectrometry in clinical and forensic toxicology.

    Science.gov (United States)

    Maurer, Hans H

    2007-08-01

    This paper reviews multi-analyte single-stage and tandem liquid chromatography-mass spectrometry (LC-MS) procedures using different mass analyzers (quadrupole, ion trap, time-of-flight) for screening, identification, and/or quantification of drugs, poisons, and/or their metabolites in blood, plasma, serum, or urine published after 2004. Basic information about the biosample assayed, work-up, LC column, mobile phase, ionization type, mass spectral detection mode, and validation data of each procedure is summarized in tables. The following analytes are covered: drugs of abuse, analgesics, opioids, sedative-hypnotics, benzodiazepines, antidepressants including selective-serotonin reuptake inhibitors (SSRIs), herbal phenalkylamines (ephedrines), oral antidiabetics, antiarrhythmics and other cardiovascular drugs, antiretroviral drugs, toxic alkaloids, quaternary ammonium drugs and herbicides, and dialkylphosphate pesticides. The pros and cons of the reviewed procedures are critically discussed, particularly, the need for studies on matrix effects, selectivity, analyte stability, and the use of stable-isotope labeled internal standards instead of unlabeled therapeutic drugs. In conclusion, LC-MS will probably become a gold standard for detection of very low concentrations particularly in alternative matrices and for quantification in clinical and forensic toxicology. However, some drawbacks still need to be addressed and finally overcome.

  3. Integration of Electrochemistry with Ultra Performance Liquid Chromatography/Mass Spectrometry (UPLC/MS)

    Science.gov (United States)

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A.; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of disulfide bond-containing proteins/peptides. In our approach, a protein/peptide mixture sample undergoes fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and MS/MS analyses. The electrochemical cell is coupled to MS using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, disulfide bond-containing peptides can be differentiated from those without disulfide bonds as the former are electroactive and reducible. Tandem MS analysis of the disulfide-reduced peptide ions provides increased sequence and disulfide linkage pattern information. In a reactive DESI-MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which would be useful in top-down protein structure analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1~2 orders of magnitude by using UPLC for the LC/EC/MS platform, in comparison to the previously used high performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis. PMID:26307715

  4. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air.

  5. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  6. Metabolite profiling and quantification of phytochemicals in potato extracts using ultra-high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Chong, Esther Swee Lan; McGhie, Tony K; Heyes, Julian A; Stowell, Kathryn M

    2013-12-01

    Potatoes contain a diverse range of phytochemicals which have been suggested to have health benefits. Metabolite profiling and quantification were conducted on plant extracts made from a white potato cultivar and 'Urenika', a purple potato cultivar traditionally consumed by New Zealand Maori. There is limited published information regarding the metabolite profile of Solanum tuberosum cultivar 'Urenika'. Using ultra-high- performance liquid chromatography-mass spectrometry (UHPLC-MS), a total of 31 compounds were identified and quantified in the potato extracts. The majority of the compounds were identified for the first time in 'Urenika'. These compounds include several types of anthocyanins, hydroxycinnamic acid (HCA) derivatives, and hydroxycinnamic amides (HCAA). Six classes of compounds, namely organic acids, amino acids, HCA, HCAA, flavonols and glycoalkaloids, were present in both extracts but quantities varied between the two extracts. The unknown plant metabolites in both potato extracts were assigned with molecular formulae and identified with high confidence. Quantification of the metabolites was achieved using a number of appropriate standards. High-resolution mass spectrometry data critical for accurate identification of unknown phytochemicals were achieved and could be added to potato or plant metabolomic database. © 2013 Society of Chemical Industry.

  7. Liquid-chromatography mass spectrometry (LC-MS) of steroid hormone metabolites and its applications

    Science.gov (United States)

    Penning, Trevor M.; Lee, Seon-Hwa; Jin, Yi; Gutierrez, Alejandro; Blair, Ian A.

    2010-01-01

    Advances in liquid chromatography-mass spectrometry (LC-MS) can be used to measure steroid hormone metabolites in vitro and in vivo. We find that LC-Electrospray Ionization (ESI)-MS using a LCQ ion trap mass spectrometer in the negative ion mode can be used to monitor the product profile that results from 5α–dihydrotestosterone(DHT)-17β-glucuronide, DHT-17β-sulfate, and tibolone-17β-sulfate reduction catalyzed by human members of the aldo-keto reductase (AKR) 1C subfamily and assign kinetic constants to these reactions. We also developed a stable-isotope dilution LC-electron capture atmospheric pressure chemical ionization (ECAPCI)-MS method for the quantitative analysis of estrone (E1) and its metabolites as pentafluorobenzyl (PFB) derivatives in human plasma in the attomole range. The limit of detection for E1-PFB was 740 attomole on column. Separations can be performed using normal-phase LC because ionization takes place in the gas phase rather than in solution. This permits efficient separation of the regioisomeric 2- and 4-methoxy-E1. The method was validated for the simultaneous analysis of plasma E2 and its metabolites: 2-methoxy-E2, 4-methoxy-E2, 16α-hydroxy-E2, estrone (E1), 2-methoxy-E1, 4-methoxy-EI, and 16α-hydroxy-E1 from 5 pg/mL to 2,000 pg/mL. Our LC-MS methods have sufficient sensitivity to detect steroid hormone levels in prostate and breast tumors and should aid their molecular diagnosis and treatment. PMID:20083198

  8. Liquid chromatography/mass spectrometry analysis of exhaled leukotriene B4 in asthmatic children

    Directory of Open Access Journals (Sweden)

    Barnes Peter J

    2005-10-01

    Full Text Available Abstract Background The role of leukotriene (LT B4, a potent inflammatory mediator, in atopic asthmatic and atopic nonasthmatic children is largely unknown. The lack of a gold standard technique for measuring LTB4 in exhaled breath condensate (EBC has hampered its quantitative assessment in this biological fluid. We sought to measure LTB4 in EBC in atopic asthmatic children and atopic nonasthmatic children. Exhaled nitric oxide (NO was measured as an independent marker of airway inflammation. Methods Fifteen healthy children, 20 atopic nonasthmatic children, 25 steroid-naïve atopic asthmatic children, and 22 atopic asthmatic children receiving inhaled corticosteroids were studied. The study design was of cross-sectional type. Exhaled LTB4 concentrations were measured using liquid chromatography/mass spectrometry-mass spectrometry (LC/MS/MS with a triple quadrupole mass spectrometer. Exhaled NO was measured by chemiluminescence with a single breath on-line method. LTB4 values were expressed as the total amount (in pg of eicosanoid expired in the 15-minute breath test. Kruskal-Wallis test was used to compare groups. Results Compared with healthy children [87.5 (82.5–102.5 pg, median and interquartile range], exhaled LTB4 was increased in steroid-naïve atopic asthmatic [255.1 (175.0–314.7 pg, p 4 than steroid-naïve asthmatics [125.0 (25.0–245.0 pg vs 255.1 (175.0–314.7 pg, p Conclusion In contrast to exhaled NO concentrations, exhaled LTB4 values are selectively elevated in steroid-naïve atopic asthmatic children, but not in atopic nonasthmatic children. Although placebo control studies are warranted, inhaled corticosteroids seem to reduce exhaled LTB4 in asthmatic children. LC/MS/MS analysis of exhaled LTB4 might provide a non-invasive, sensitive, and quantitative method for airway inflammation assessment in asthmatic children.

  9. Conventional-Flow Liquid Chromatography-Mass Spectrometry for Exploratory Bottom-Up Proteomic Analyses.

    Science.gov (United States)

    Lenčo, Juraj; Vajrychová, Marie; Pimková, Kristýna; Prokšová, Magdaléna; Benková, Markéta; Klimentová, Jana; Tambor, Vojtěch; Soukup, Ondřej

    2018-04-17

    Due to its sensitivity and productivity, bottom-up proteomics based on liquid chromatography-mass spectrometry (LC-MS) has become the core approach in the field. The de facto standard LC-MS platform for proteomics operates at sub-μL/min flow rates, and nanospray is required for efficiently introducing peptides into a mass spectrometer. Although this is almost a "dogma", this view is being reconsidered in light of developments in highly efficient chromatographic columns, and especially with the introduction of exceptionally sensitive MS instruments. Although conventional-flow LC-MS platforms have recently penetrated targeted proteomics successfully, their possibilities in discovery-oriented proteomics have not yet been thoroughly explored. Our objective was to determine what are the extra costs and what optimization and adjustments to a conventional-flow LC-MS system must be undertaken to identify a comparable number of proteins as can be identified on a nanoLC-MS system. We demonstrate that the amount of a complex tryptic digest needed for comparable proteome coverage can be roughly 5-fold greater, providing the column dimensions are properly chosen, extra-column peak dispersion is minimized, column temperature and flow rate are set to levels appropriate for peptide separation, and the composition of mobile phases is fine-tuned. Indeed, we identified 2 835 proteins from 2 μg of HeLa cells tryptic digest separated during a 60 min gradient at 68 μL/min on a 1.0 mm × 250 mm column held at 55 °C and using an aqua-acetonitrile mobile phases containing 0.1% formic acid, 0.4% acetic acid, and 3% dimethyl sulfoxide. Our results document that conventional-flow LC-MS is an attractive alternative for bottom-up exploratory proteomics.

  10. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    OpenAIRE

    Suriyavathana Muthukrishnan; Subha Palanisamy; Senthilkumar Subramanian; Sumathi Selvaraj; Kavitha Rani Mari; Ramalingam Kuppulingam

    2016-01-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. Th...

  11. Gas chromatography-mass spectrometry and high-performance liquid chromatographic analyses of thermal degradation products of common plastics

    OpenAIRE

    Pacakova, V.; Leclercq, P.A.

    1991-01-01

    The thermo-oxidation of five commonly used materials, namely low-density polyethylene, retarded polyethylene, paper with a polyethylene foil, a milk package and filled polypropylene, was studied. Capillary gas chromatography and gas chromatography-mass spectrometry were used to analyze the volatile degradation products, while high-performance liquid chromatography was employed to measure polycyclic aromatic hydrocarbons. The results are discussed from the point of view of toxicity of the prod...

  12. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Masiá, Ana [Food and Environmental Safety Research Group, Department of Preventive Medicine and Public Health, Food Science, Toxicology and Legal Medicine, University of Valencia, Valencia (Spain); Research Center on Desertification (CIDE, UV-CSIC-GV), Carretera Moncada-Náquera, Moncada (Spain); Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin [Unit of Public Health, Hygiene and Environmental Health, Department of Preventive Medicine and Public Health, Food Science, Toxicology and Legal Medicine, University of Valencia, Valencia (Spain); CIBER Epidemiología y Salud Pública (CIBERESP), Madrid (Spain); Center for Advanced Research in Public Health (CSISP-FISABIO), Valencia (Spain); Picó, Yolanda, E-mail: Yolanda.Pico@uv.es [Food and Environmental Safety Research Group, Department of Preventive Medicine and Public Health, Food Science, Toxicology and Legal Medicine, University of Valencia, Valencia (Spain); Research Center on Desertification (CIDE, UV-CSIC-GV), Carretera Moncada-Náquera, Moncada (Spain); CIBER Epidemiología y Salud Pública (CIBERESP), Madrid (Spain)

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS. - Highlights: • An overview of status and future trends in this field. • Analytical method's compliance with guidelines to ensure reliability. • QuEChERS platform is a referent to extract both, pesticides and veterinary drugs in food. • The progress that liquid chromatography has shown in recent years is revised. • Determination of target, non-target and unknowns is

  13. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review

    International Nuclear Information System (INIS)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-01-01

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS. - Highlights: • An overview of status and future trends in this field. • Analytical method's compliance with guidelines to ensure reliability. • QuEChERS platform is a referent to extract both, pesticides and veterinary drugs in food. • The progress that liquid chromatography has shown in recent years is revised. • Determination of target, non-target and unknowns is covered.

  14. Dansylation isotope labeling liquid chromatography mass spectrometry for parallel profiling of human urinary and fecal submetabolomes

    Energy Technology Data Exchange (ETDEWEB)

    Su, Xiaoling [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Wang, Nan [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Chen, Deying [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Lu, Yingfeng [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Huan, Tao [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Xu, Wei [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Li, Lanjuan, E-mail: ljli@zju.edu.cn [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China)

    2016-01-15

    Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on {sup 12}C-labeling of individual samples and {sup 13}C-labeling of a pooled urine or pooled feces and subsequent analysis of the {sup 13}C-/{sup 12}C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome

  15. Dansylation isotope labeling liquid chromatography mass spectrometry for parallel profiling of human urinary and fecal submetabolomes

    International Nuclear Information System (INIS)

    Su, Xiaoling; Wang, Nan; Chen, Deying; Li, Yunong; Lu, Yingfeng; Huan, Tao; Xu, Wei; Li, Liang; Li, Lanjuan

    2016-01-01

    Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on "1"2C-labeling of individual samples and "1"3C-labeling of a pooled urine or pooled feces and subsequent analysis of the "1"3C-/"1"2C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome. - Highlights: • A

  16. Automated mass correction and data interpretation for protein open-access liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wagner, Craig D; Hall, John T; White, Wendy L; Miller, Luke A D; Williams, Jon D

    2007-02-01

    Characterization of recombinant protein purification fractions and final products by liquid chromatography-mass spectrometry (LC/MS) are requested more frequently each year. A protein open-access (OA) LC/MS system was developed in our laboratory to meet this demand. This paper compares the system that we originally implemented in our facilities in 2003 to the one now in use, and discusses, in more detail, recent enhancements that have improved its robustness, reliability, and data reporting capabilities. The system utilizes instruments equipped with reversed-phase chromatography and an orthogonal accelerated time-of-flight mass spectrometer fitted with an electrospray source. Sample analysis requests are accomplished using a simple form on a web-enabled laboratory information management system (LIMS). This distributed form is accessible from any intranet-connected company desktop computer. Automated data acquisition and processing are performed using a combination of in-house (OA-Self Service, OA-Monitor, and OA-Analysis Engine) and vendor-supplied programs (AutoLynx, and OpenLynx) located on acquisition computers and off-line processing workstations. Analysis results are then reported via the same web-based LIMS. Also presented are solutions to problems not addressed on commercially available, small-molecule OA-LC/MS systems. These include automated transforming of mass-to-charge (m/z) spectra to mass spectra and automated data interpretation that considers minor variants to the protein sequence-such as common post-translational modifications (PTMs). Currently, our protein OA-LC/MS platform runs on five LC/MS instruments located in three separate GlaxoSmithKline R&D sites in the US and UK. To date, more than 8000 protein OA-LC/MS samples have been analyzed. With these user friendly and highly automated OA systems in place, mass spectrometry plays a key role in assessing the quality of recombinant proteins, either produced at our facilities or bought from external

  17. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    Science.gov (United States)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to

  18. Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    2016-01-01

    Levetiracetam (LEV) is an antiepileptic drug that is clinically effective in generalized and partial epilepsy syndromes. The use of this drug has been increasing in clinical practice and intra- or -interindividual variability has been exhibited for special population. For this reason, bioanalytical methods are required for drug monitoring in biological matrices. So this work presents a dispersive liquid-liquid microextraction method followed by gas chromatography-mass spectrometry (DLLME-GC-MS) for LEV quantification in human plasma. However, due to the matrix complexity a previous purification step is required. Unlike other pretreatment techniques presented in the literature, for the first time, a procedure employing ultrafiltration tubes Amicon® (10 kDa porous size) without organic solvent consumption was developed. GC-MS analyses were carried out using a linear temperature program, capillary fused silica column, and helium as the carrier gas. DLLME optimized parameters were type and volume of extraction and dispersing solvents, salt addition, and vortex agitation time. Under chosen parameters (extraction solvent: chloroform, 130 μL; dispersing solvent: isopropyl alcohol, 400 μL; no salt addition and no vortex agitation time), the method was completely validated and all parameters were in agreement with the literature recommendations. LEV was quantified in patient's plasma sample using less than 550 μL of organic solvent. PMID:27830105

  19. Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Greyce Kelly Steinhorst Alcantara

    2016-01-01

    Full Text Available Levetiracetam (LEV is an antiepileptic drug that is clinically effective in generalized and partial epilepsy syndromes. The use of this drug has been increasing in clinical practice and intra- or -interindividual variability has been exhibited for special population. For this reason, bioanalytical methods are required for drug monitoring in biological matrices. So this work presents a dispersive liquid-liquid microextraction method followed by gas chromatography-mass spectrometry (DLLME-GC-MS for LEV quantification in human plasma. However, due to the matrix complexity a previous purification step is required. Unlike other pretreatment techniques presented in the literature, for the first time, a procedure employing ultrafiltration tubes Amicon® (10 kDa porous size without organic solvent consumption was developed. GC-MS analyses were carried out using a linear temperature program, capillary fused silica column, and helium as the carrier gas. DLLME optimized parameters were type and volume of extraction and dispersing solvents, salt addition, and vortex agitation time. Under chosen parameters (extraction solvent: chloroform, 130 μL; dispersing solvent: isopropyl alcohol, 400 μL; no salt addition and no vortex agitation time, the method was completely validated and all parameters were in agreement with the literature recommendations. LEV was quantified in patient’s plasma sample using less than 550 μL of organic solvent.

  20. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    International Nuclear Information System (INIS)

    Shen, Weifeng; Han, Wei; Li, Yunong; Meng, Zhiqi; Cai, Leiming; Li, Liang

    2016-01-01

    Silkworm (Bombyx mori) is a very useful target insect for evaluation of endocrine disruptor chemicals (EDCs) due to mature breeding techniques, complete endocrine system and broad basic knowledge on developmental biology. Comparative metabolomics of silkworms with and without EDC exposure offers another dimension of studying EDCs. In this work, we report a workflow on metabolomic profiling of silkworm hemolymph based on high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) and demonstrate its application in studying the metabolic changes associated with the pesticide dichlorodiphenyltrichloroethane (DDT) exposure in silkworm. Hemolymph samples were taken from mature silkworms after growing on diet that contained DDT at four different concentrations (1, 0.1, 0.01, 0.001 ppm) as well as on diet without DDT as controls. They were subjected to differential "1"2C-/"1"3C-dansyl labeling of the amine/phenol submetabolome, LC-UV quantification of the total amount of labeled metabolites for sample normalization, and LC-MS detection and relative quantification of individual metabolites in comparative samples. The total concentration of labeled metabolites did not show any significant change between four DDT-treatment groups and one control group. Multivariate statistical analysis of the metabolome data set showed that there was a distinct metabolomic separation between the five groups. Out of the 2044 detected peak pairs, 338 and 1471 metabolites have been putatively identified against the HMDB database and the EML library, respectively. 65 metabolites were identified by the dansyl library searching based on the accurate mass and retention time. Among the 65 identified metabolites, 33 positive metabolites had changes of greater than 1.20-fold or less than 0.83-fold in one or more groups with p-value of smaller than 0.05. Several useful biomarkers including serine, methionine, tryptophan, asymmetric dimethylarginine, N

  1. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Weifeng [Key Laboratory of Detection for Pesticide Residues, Ministry of Agriculture (China); Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Han, Wei; Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Meng, Zhiqi [Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Cai, Leiming, E-mail: cailm@mail.zaas.ac.cn [Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2016-10-26

    Silkworm (Bombyx mori) is a very useful target insect for evaluation of endocrine disruptor chemicals (EDCs) due to mature breeding techniques, complete endocrine system and broad basic knowledge on developmental biology. Comparative metabolomics of silkworms with and without EDC exposure offers another dimension of studying EDCs. In this work, we report a workflow on metabolomic profiling of silkworm hemolymph based on high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) and demonstrate its application in studying the metabolic changes associated with the pesticide dichlorodiphenyltrichloroethane (DDT) exposure in silkworm. Hemolymph samples were taken from mature silkworms after growing on diet that contained DDT at four different concentrations (1, 0.1, 0.01, 0.001 ppm) as well as on diet without DDT as controls. They were subjected to differential {sup 12}C-/{sup 13}C-dansyl labeling of the amine/phenol submetabolome, LC-UV quantification of the total amount of labeled metabolites for sample normalization, and LC-MS detection and relative quantification of individual metabolites in comparative samples. The total concentration of labeled metabolites did not show any significant change between four DDT-treatment groups and one control group. Multivariate statistical analysis of the metabolome data set showed that there was a distinct metabolomic separation between the five groups. Out of the 2044 detected peak pairs, 338 and 1471 metabolites have been putatively identified against the HMDB database and the EML library, respectively. 65 metabolites were identified by the dansyl library searching based on the accurate mass and retention time. Among the 65 identified metabolites, 33 positive metabolites had changes of greater than 1.20-fold or less than 0.83-fold in one or more groups with p-value of smaller than 0.05. Several useful biomarkers including serine, methionine, tryptophan, asymmetric dimethylarginine, N

  2. Analysis of L-serine-O-phosphate in cerebrospinal spinal fluid by derivatization-liquid chromatography/mass spectrometry.

    Science.gov (United States)

    McNaney, Colleen A; Benitex, Yulia; Luchetti, David; Labasi, Jeffrey M; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M

    2014-05-01

    L-serine-O-phosphate (L-SOP), the precursor of L-serine, is a potent agonist against the group III metabotropic glutamate receptors (mGluRs) and, thus, is of interest as a potential biomarker for monitoring modulation of neurotransmitter release. So far, no reports are available on the analysis of L-SOP in cerebrospinal fluid (CSF). Here a novel method is presented to determine L-SOP levels in CSF employing precolumn derivatization with (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) coupled to liquid chromatography/mass spectrometry (derivatization-LC/MS, d-LC/MS). Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Pharmacokinetic Studies of Chinese Medicinal Herbs Using an Automated Blood Sampling System and Liquid Chromatography-mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yu-Tse Wu

    2012-01-01

    Full Text Available The safety of herbal products is one of the major concerns for the modernization of traditional Chinese medicine, and pharmacokinetic data of medicinal herbs guide us to design the rational use of the herbal formula. This article reviews the advantages of the automated blood sampling (ABS systems for pharmacokinetic studies. In addition, three commonly used sample preparative methods, protein precipitation, liquid-liquid extraction and solid-phase extraction, are introduced. Furthermore, the definition, causes and evaluation of matrix effects in liquid chromatography-mass spectrometry (LC/MS analysis are demonstrated. Finally, we present our previous works as practical examples of the application of ABS systems and LC/MS for the pharmacokinetic studies of Chinese medicinal herbs.

  4. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Dubbels, R.; Klenke, E.; Schnakenberg, E.; Ehlers, C.; Schloot, W.; Reiter, R.J.; Goebel, A.; Schiware, H.W.

    1995-01-01

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs

  5. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations.

    Science.gov (United States)

    Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A

    2011-01-01

    Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.

  6. Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bassarab, P; Williams, D; Dean, J R; Ludkin, E; Perry, J J

    2011-02-04

    A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Prostate cell membrane chromatography-liquid chromatography-mass spectrometry for screening of active constituents from Uncaria rhynchophylla.

    Science.gov (United States)

    He, Jianyu; Han, Shengli; Yang, Fangfang; Zhou, Nan; Wang, Sicen

    2013-01-01

    Uncaria rhynchophylla is a traditional Chinese medicinal herb used to treat hypertension and convulsive disorders such as epilepsy. Rat prostate cell membrane chromatography combined with liquid chromatography-mass spectrometry (LC-MS) was used to identify active constituents from U. rhynchophylla extracts. Four compounds (corynoxeine, isorhynchophylline, isocorynoxeine and rhynchophylline) were discovered. Competitive binding assay results indicated that the four compounds were in direct competition at a single common binding site and interacted with α1A adrenergic receptors (α1A-AR) in a manner similar to tamsulosin. Affinity constant values of the four compounds binding with α1A-AR were also measured using rat prostate cell membrane chromatography (CMC). Finally, their pharmacodynamic effects were tested on rat caudal arteries. This CMC combined LC-MS system offers a means of drug discovery by screening natural medicinal herbs for new pharmacologically active molecules targeting specific receptors.

  8. Determination of regulatory ionophore coccidiostat residues in feedstuffs at carry-over levels by liquid chromatography-mass spectrometry

    Science.gov (United States)

    Stramenga, Arianna; Colagrande, Maria Novella; Campana, Guido; Scortichini, Giampiero; Migliorati, Giacomo; Compagnone, Dario

    2017-01-01

    In this study samples of feedstuffs were collected from different feed mills and animal farms located in central Italy and analyzed for ionophore coccidiostat residues at carry-over levels by liquid chromatography-mass spectrometry. Since unavoidable cross-contamination of feedstuffs may occur during their production as well as distribution and storage, the collection of samples covered all these different stages. Residues of lasalocid, monensin, salinomycin and maduramicin were detected in 32.4% of samples, both at production and storage level. The maximum content for unavoidable carry-over set by Regulation (EU) No 574/2011 was exceeded in 11.3% of samples. The variability of the results highlighted the different approach of each investigated feed business operator to avoid any cross-contamination in non-target feed. The method developed in this study can be able to detect ionophore coccidiostats at low concentrations consequent to carry-over. PMID:28792977

  9. FRAGMENTATION STUDIES OF D6,7-ANHIDROERITROMISIN-A BY LIQUID CHROMATOGRAPHY-MASS SPECTROSCOPY (LC-MS

    Directory of Open Access Journals (Sweden)

    Khairan Khairan

    2010-06-01

    Full Text Available Semisynthesis of D6,7-Anhydroerythromycin-A was done by biomodification technique by addition of 0.2% INH into a culture fermentation of Saccharopolyspora erythraea ATCC 11635 in medium Hutchinson. The aim of this research is to studies of fragmentation pattern from new matabolite of D6,7-Anhydroerythromycin-A by Liquid Chromatography-Mass Spectroscopy (LC-MS and the ionization of mass spectroscopy is use by ESI (Electrospray Ionization pattern. The FT-IR spectrometric analyzes showed a stretching vibration of C=C conjugated group at wave number 1602.7 cm-1. This C=C conjugated vibration indicated the existence of double bond between C6 and C7 (D6,7, this confirmed that isolate contained D6,7-Anhydroerythromycin-A (the possibility of D6,7 was positive. For complementation, a LC-MS (Liquid Chromatography-Mass Spectroscopy analyzes using ESI-MS (Electrospray Ionization-Mass Spectroscopy ionization pattern was conducted to the isolate which resulted Quassimolecular ions [M+H]+ of D7,8- and D6,7-Anhydroerythromycin-A. LC-MS spectrogram of the isolate, which gave two peaks of m/z 732.2460 and m/z 716.2522, confirmed that the m/z 732.2460 possibly was D7,8-Anhydroerythromycin-A, while the m/z 716.2502 and m/z 715.2522 possibly were D6,7-Anhydroerythromycin-A.   Keywords: isoniazid, enoyl reduction, D6,7-Anhidroeritromisin-A, fragmentation, LC-MS.

  10. Bayesian approach to peak deconvolution and library search for high resolution gas chromatography - Mass spectrometry

    NARCIS (Netherlands)

    Barcaru, A.; Mol, H.G.J.; Tienstra, M.; Vivó-Truyols, G.

    2017-01-01

    A novel probabilistic Bayesian strategy is proposed to resolve highly coeluting peaks in high-resolution GC-MS (Orbitrap) data. Opposed to a deterministic approach, we propose to solve the problem probabilistically, using a complete pipeline. First, the retention time(s) for a (probabilistic) number

  11. Recent trends in application of multivariate curve resolution approaches for improving gas chromatography-mass spectrometry analysis of essential oils.

    Science.gov (United States)

    Jalali-Heravi, Mehdi; Parastar, Hadi

    2011-08-15

    Essential oils (EOs) are valuable natural products that are popular nowadays in the world due to their effects on the health conditions of human beings and their role in preventing and curing diseases. In addition, EOs have a broad range of applications in foods, perfumes, cosmetics and human nutrition. Among different techniques for analysis of EOs, gas chromatography-mass spectrometry (GC-MS) is the most important one in recent years. However, there are some fundamental problems in GC-MS analysis including baseline drift, spectral background, noise, low S/N (signal to noise) ratio, changes in the peak shapes and co-elution. Multivariate curve resolution (MCR) approaches cope with ongoing challenges and are able to handle these problems. This review focuses on the application of MCR techniques for improving GC-MS analysis of EOs published between January 2000 and December 2010. In the first part, the importance of EOs in human life and their relevance in analytical chemistry is discussed. In the second part, an insight into some basics needed to understand prospects and limitations of the MCR techniques are given. In the third part, the significance of the combination of the MCR approaches with GC-MS analysis of EOs is highlighted. Furthermore, the commonly used algorithms for preprocessing, chemical rank determination, local rank analysis and multivariate resolution in the field of EOs analysis are reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Bayesian approach to peak deconvolution and library search for high resolution gas chromatography - Mass spectrometry.

    Science.gov (United States)

    Barcaru, A; Mol, H G J; Tienstra, M; Vivó-Truyols, G

    2017-08-29

    A novel probabilistic Bayesian strategy is proposed to resolve highly coeluting peaks in high-resolution GC-MS (Orbitrap) data. Opposed to a deterministic approach, we propose to solve the problem probabilistically, using a complete pipeline. First, the retention time(s) for a (probabilistic) number of compounds for each mass channel are estimated. The statistical dependency between m/z channels was implied by including penalties in the model objective function. Second, Bayesian Information Criterion (BIC) is used as Occam's razor for the probabilistic assessment of the number of components. Third, a probabilistic set of resolved spectra, and their associated retention times are estimated. Finally, a probabilistic library search is proposed, computing the spectral match with a high resolution library. More specifically, a correlative measure was used that included the uncertainties in the least square fitting, as well as the probability for different proposals for the number of compounds in the mixture. The method was tested on simulated high resolution data, as well as on a set of pesticides injected in a GC-Orbitrap with high coelution. The proposed pipeline was able to detect accurately the retention times and the spectra of the peaks. For our case, with extremely high coelution situation, 5 out of the 7 existing compounds under the selected region of interest, were correctly assessed. Finally, the comparison with the classical methods of deconvolution (i.e., MCR and AMDIS) indicates a better performance of the proposed algorithm in terms of the number of correctly resolved compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cho, Sung-Hee; Lee, Sun-Kyung; Kim, Chong Hyeak

    2018-05-01

    Polycyclic aromatic hydrocarbons (PAHs), organic compounds formed by at least two condensed aromatic rings, are ubiquitous environmental pollutants that are produced by incomplete combustion of organic materials. PAHs have been classified as carcinogenIC to humans by the International Agency for Research on Cancer, because they can bind to DNA, causing mutations. Therefore, the levels of PAHs in human urine can be used as an indicator for potential carcinogenesis and cell mutation. An analytical method was developed for the accurate measurement of PAHs in urine using high-resolution gas chromatography-mass spectrometry. Urine samples were extracted by an Oasis HLB extraction cartridge after enzymatic hydrolysis with a β-glucuronidase/arylsulfatase cocktail. The 18 PAHs were separated using an Agilent DB-5 MS capillary column (30 m × 0.25 mm, 0.25 μm) and monitored by time-of-flight mass spectrometry. Under the optimized method, the linearity of calibration curves was >0.994. The limits of detection at a signal-to-noise ratio of 3 were 10-100 ng/L. The coefficients of variation were in the range of 0.4-9.0%. The present method was highly accurate for simultaneous determination of 18 PAHs in human urine and could be applied to monitoring and biomedical investigations to check exposure of PAHs. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Intra- and inter-metabolite correlation spectroscopy of tomato metabolomics data obtained by liquid chromatography-mass spectrometry and nuclear magnetic resonance

    NARCIS (Netherlands)

    Moco, S.I.A.; Forshed, J.; Vos, de C.H.; Bino, R.J.; Vervoort, J.J.M.

    2008-01-01

    Nuclear magnetic resonance (NMR) and liquid chromatography-mass spectrometry (LCMS) are frequently used as technological platforms for metabolomics applications. In this study, the metabolic profiles of ripe fruits from 50 different tomato cultivars, including beef, cherry and round types, were

  15. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  16. Combined liquid chromatography-mass spectrometry for trace analysis of pharmaceuticals

    International Nuclear Information System (INIS)

    Schmidt, L.; Danigel, H.; Jungclas, H.

    1982-01-01

    A 252 Cf-plasma desorption mass spectrometer (PDMS) for the analysis of thin layers from nonvolatile organic samples has been set up to be combined with a liquid chromatograph. A novel interface performs the direct inlet of the liquid sample through a capillary into the vacuum system of the spectrometer. Samples of drugs are periodically collected, transferred to the ion source and analysed using a rotating disk. This on-line sample preparation has been tested for three antiarrhythmic drugs using various solvents and mixtures. (orig.)

  17. Picomolar concentrations of morphine in human urine determined by dansyl derivatization and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Lamshöft, Marc; Grobe, Nadja; Spiteller, Michael

    2011-04-15

    Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml). Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Resolution of co-eluting compounds of Cannabis Sativa in comprehensive two-dimensional gas chromatography/mass spectrometry detection with Multivariate Curve Resolution-Alternating Least Squares.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Amigo, José Manuel; Etxebarria, Nestor

    2014-04-01

    Comprehensive Two Dimensional Gas Chromatography - Mass Spectrometry (GC × GC/qMS) analysis of Cannabis sativa extracts shows a high complexity due to the large variety of terpenes and cannabinoids and to the fact that the complete resolution of the peaks is not straightforwardly achieved. In order to support the resolution of the co-eluted peaks in the sesquiterpene and the cannabinoid chromatographic region the combination of Multivariate Curve Resolution and Alternating Least Squares algorithms was satisfactorily applied. As a result, four co-eluting areas were totally resolved in the sesquiterpene region and one in the cannabinoid region in different samples of Cannabis sativa. The comparison of the mass spectral profiles obtained for each resolved peak with theoretical mass spectra allowed the identification of some of the co-eluted peaks. Finally, the classification of the studied samples was achieved based on the relative concentrations of the resolved peaks. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Improvement of recovery and repeatability in liquid chromatography-mass spectrometry analysis of peptides

    NARCIS (Netherlands)

    van Midwoud, Paul M.; Rieux, Laurent; Bischoff, Rainer; Verpoorte, Elisabeth; Niederlander, Harm A. G.

    2007-01-01

    Poor repeatability of peak areas is a problem frequently encountered in peptide analysis with nanoLiquid Chromatography coupled on-line with Mass Spectrometry (nanoLC-MS). As a result, quantitative analysis will be seriously hampered unless the observed variability can be corrected in some way.

  20. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with

  1. Optimization of the combination micro-high-performance liquid-chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Haider, K.

    1997-03-01

    The coupling of liquid chromatography and mass spectrometry is still growing in significance. In this thesis, a particle beam interface has been investigated for combining ion chromatography with mass spectrometric detection. To introduce the eluent directly (without membrane suppressor) into the spectrometer, only methods with low flow rates like microcolumn chromatography can be used. For the preparation of the columns, reversed-phase and silica-based anion exchange materials were packed into PEEK, steel and fused-silica capillaries with i.d. from 130 to 1000 μm using different methods. The performance of the particle beam interface (modified with a new miniaturized aerosol generator) and the mass spectrometric detection has been studied for a series of inorganic anions as well as aminopolycarboxylic acids and the metal-EDTA complexes. Detection limits between 10 and 100 ng injected could be achieved in the multiple ion detection mode of the mass spectrometer for the investigated solutes. A second type of interface, the direct liquid introduction (DLI) has been used to analyze the priority pollutant phenols. This interface is based on a modified GC-interface into the MS. Separation columns used so far include packed fused-silica capillaries with inner diameter of 75 μm and polystyrene-divinylbenzene (functionalized with tert. butyl groups) as stationary phase. Aspects of instrumentation and effects of chemical ionization in the direct liquid introduction mode are discussed. (author)

  2. An analytical method for cyclosporine using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kanduru, Srividya V; Somayaji, Vishwa; Lavasanifar, Afsaneh; Brocks, Dion R

    2010-02-01

    A liquid chromatographic mass spectrometric (LC-MS) assay has been developed for cyclosporine A (CyA) in rat plasma using amiodarone as internal standard (IS). Rat plasma (100 microL) containing drug and IS were extracted using liquid-liquid extraction with 4 mL of 95:5 ether:methanol. After evaporation of the organic layer the residue was reconstituted with 500 microL of water. Then the aqueous layer was transferred to LC-MS sample vials. A 10 microL volume was injected. The analysis was performed on a C(8) column 3.5 microm (2.1 x 50 mm) heated to 60 degrees C with a mobile phase consisting of acetonitrile:methanol:0.2% NH(4)OH (60:20:20) at an isocratic flow-rate of 0.2 mL/min. The ions used for quantitation of CyA and IS were m/z 1202.8 and 645.9, with retention times of 3.35 and 4.72 min, respectively. Linear relationships (r(2) > 0.99) were achieved between plasma or blood concentration and peak height ratios (drug:IS) over the concentration range 50-5000 ng/mL. The CV% and mean error were <19%. Based on validation data, the lower limit of quantification for the assay was 50 ng/mL. The reported assay method displayed high measures of linearity, sensitivity, reliability and precision, allowing its applicability in pharmacokinetic studies in rat. (c) 2009 John Wiley & Sons, Ltd.

  3. Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.

  4. Analysis of glyphosate residues in cereals using liquid chromatography-mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Granby, Kit; Johannesen, S.; Gabrielsen, Martin Vahl

    2003-01-01

    A fast and specific method for the determination of glyphosate in cereals is described. The method is based on extraction with water by ultrasonication. The samples are cleaned up and separated by high-performance liquid chromatography on a polystyrene-based reverse-phase column (clean-up) in ser......A fast and specific method for the determination of glyphosate in cereals is described. The method is based on extraction with water by ultrasonication. The samples are cleaned up and separated by high-performance liquid chromatography on a polystyrene-based reverse-phase column (clean...... monitored m/z 168--> 150 (glyphosate) and 170-->152 (internal standard 2- 13 (CN)-N-15-glyphosate) for quantification. The mean recovery was 85% ( n =32) at spiking levels from 0.03 to 0.33 mg kg(-1) . From 1998 to 2001, from the analysis of about 50 samples per annum, a reduction in the glyphosate residues...... was observed owing to a Danish trade decision not to use grain with glyphosate residues for milling or bread production....

  5. Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis

    Science.gov (United States)

    Gelhaus, Stacy L.; Mesaros, A. Clementina; Blair, Ian A.

    2011-01-01

    The metabolism of fatty acids, such as arachidonic acid (AA) and linoleic acid (LA), results in the formation of oxidized bioactive lipids, including numerous stereoisomers1,2. These metabolites can be formed from free or esterified fatty acids. Many of these oxidized metabolites have biological activity and have been implicated in various diseases including cardiovascular and neurodegenerative diseases, asthma, and cancer3-7. Oxidized bioactive lipids can be formed enzymatically or by reactive oxygen species (ROS). Enzymes that metabolize fatty acids include cyclooxygenase (COX), lipoxygenase (LO), and cytochromes P450 (CYPs)1,8. Enzymatic metabolism results in enantioselective formation whereas ROS oxidation results in the racemic formation of products. While this protocol focuses primarily on the analysis of AA- and some LA-derived bioactive metabolites; it could be easily applied to metabolites of other fatty acids. Bioactive lipids are extracted from cell lysate or media using liquid-liquid (l-l) extraction. At the beginning of the l-l extraction process, stable isotope internal standards are added to account for errors during sample preparation. Stable isotope dilution (SID) also accounts for any differences, such as ion suppression, that metabolites may experience during the mass spectrometry (MS) analysis9. After the extraction, derivatization with an electron capture (EC) reagent, pentafluorylbenzyl bromide (PFB) is employed to increase detection sensitivity10,11. Multiple reaction monitoring (MRM) is used to increase the selectivity of the MS analysis. Before MS analysis, lipids are separated using chiral normal phase high performance liquid chromatography (HPLC). The HPLC conditions are optimized to separate the enantiomers and various stereoisomers of the monitored lipids12. This specific LC-MS method monitors prostaglandins (PGs), isoprostanes (isoPs), hydroxyeicosatetraenoic acids (HETEs), hydroxyoctadecadienoic acids (HODEs), oxoeicosatetraenoic

  6. Oligosaccharide substrate preferences of human extracellular sulfatase Sulf2 using liquid chromatography-mass spectrometry based glycomics approaches.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Sulfs are extracellular endosulfatases that selectively remove the 6-O-sulfate groups from cell surface heparan sulfate (HS chain. By altering the sulfation at these particular sites, Sulfs function to remodel HS chains. As a result of the remodeling activity, HSulf2 regulates a multitude of cell-signaling events that depend on interactions between proteins and HS. Previous efforts to characterize the substrate specificity of human Sulfs (HSulfs focused on the analysis of HS disaccharides and synthetic repeating units. In this study, we characterized the substrate preferences of human HSulf2 using HS oligosaccharides with various lengths and sulfation degrees from several naturally occurring HS sources by applying liquid chromatography mass spectrometry based glycomics methods. The results showed that HSulf2 preferentially digests highly sulfated HS oligosaccharides with zero acetyl groups and this preference is length dependent. In terms of length of oligosaccharides, HSulf2 digestion induced more sulfation decrease on DP6 (DP: degree of polymerization compared to DP2, DP4 and DP8. In addition, the HSulf2 preferentially digests the oligosaccharide domain located at the non-reducing end (NRE of the HS and heparin chain. In addition, the HSulf2 digestion products were altered only for specific isomers. HSulf2 treated NRE oligosaccharides also showed greater decrease in cell proliferation than those from internal domains of the HS chain. After further chromatographic separation, we identified the three most preferred unsaturated hexasaccharide for HSulf2.

  7. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    Science.gov (United States)

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases. Copyright © 2016. Published by Elsevier B.V.

  8. Toxic Cyanobacteria in Svalbard: Chemical Diversity of Microcystins Detected Using a Liquid Chromatography Mass Spectrometry Precursor Ion Screening Method

    Directory of Open Access Journals (Sweden)

    Julia Kleinteich

    2018-04-01

    Full Text Available Cyanobacteria synthesize a large variety of secondary metabolites including toxins. Microcystins (MCs with hepato- and neurotoxic potential are well studied in bloom-forming planktonic species of temperate and tropical regions. Cyanobacterial biofilms thriving in the polar regions have recently emerged as a rich source for cyanobacterial secondary metabolites including previously undescribed congeners of microcystin. However, detection and detailed identification of these compounds is difficult due to unusual sample matrices and structural congeners produced. We here report a time-efficient liquid chromatography-mass spectrometry (LC-MS precursor ion screening method that facilitates microcystin detection and identification. We applied this method to detect six different MC congeners in 8 out of 26 microbial mat samples of the Svalbard Archipelago in the Arctic. The congeners, of which [Asp3, ADMAdda5, Dhb7] MC-LR was most abundant, were similar to those reported in other polar habitats. Microcystins were also determined using an Adda-specific enzyme-linked immunosorbent assay (Adda-ELISA. Nostoc sp. was identified as a putative toxin producer using molecular methods that targeted 16S rRNA genes and genes involved in microcystin production. The mcy genes detected showed highest similarities to other Arctic or Antarctic sequences. The LC-MS precursor ion screening method could be useful for microcystin detection in unusual matrices such as benthic biofilms or lichen.

  9. Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assay.

    Science.gov (United States)

    Wang, Xiu-Li; Zhu, Ying; Fang, Qun

    2014-01-07

    In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10-100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.

  10. Characterisation of capillary ionic liquid columns for gas chromatography-mass spectrometry analysis of fatty acid methyl esters.

    Science.gov (United States)

    Zeng, Annie Xu; Chin, Sung-Tong; Nolvachai, Yada; Kulsing, Chadin; Sidisky, Leonard M; Marriott, Philip J

    2013-11-25

    Due to their distinct chemical properties, the application of ionic liquid (IL) compounds as gas chromatography (GC) stationary phases offer unique GC separation especially in the analysis of geometric and positional fatty acid methyl ester (FAME) isomers. Elution behaviour of FAME on several commercialised IL capillary columns including phosphonium based SLB-IL59, SLB-IL60, SLB-IL61 and SLB-IL76 and imidazolium based SLB-IL82, SLB-IL100, and SLB-IL111 as well as a general purpose column SLB-5ms, were evaluated in gas chromatography-mass spectrometry (GC-MS) analysis. The phases were further characterised by using a linear solvation energy relationship (LSER) approach according to the equivalent chain length (ECL) index of FAME. Among all tested IL columns, elution temperatures of saturated FAME increased as their McReynolds' polarity value decreased, except for IL60. ECL values increased markedly as the stationary phase polarity increased, particularly for the polyunsaturated FAME. The LSER study indicated a lowest l/e value at 0.864 for IL111, displaying phase selectivity towards unsaturated FAME, with higher peak capacity within a carbon number isomer group. s and e descriptors calculated from LSER were validated by excellent correlation with dipole moments and lowest unoccupied molecular orbital (LUMO) energies, with R(2) values of 0.99 and 0.92 respectively, calculated using GAUSSIAN. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. [Structural characterization of Astragalus polysaccharides using partial acid hydrolysis-hydrophilic interaction liquid chromatography-mass spectrometry].

    Science.gov (United States)

    Liang, Tu; Fu, Qing; Xin, Huaxia; Li, Fangbing; Jin, Yu; Liang, Xinmiao

    2014-12-01

    Water-soluble polysaccharides from traditional Chinese medicine (TCM) have properties of broad-spectrum treatment and low toxicity, making them as important components in natural medicines and health products. In order to solve the problem of polysaccharides characterization caused by their complex structures, a "bottom-up" approach was developed to complete the characterization of polysaccharides from Astragalus. Firstly, Astragalus pieces were extracted with hot water and then were precipitated by ethanol to obtain Astragalus polysaccharides. Secondly, a partial acid hydrolysis method was carried out and the effects of time, acid concentration and temperature on hydrolysis were investigated. The degree of hydrolysis increased along with the increase of hydrolysis time and acid concentration. The temperature played a great role in the hydrolysis process. No hydrolysis of the polysaccharides occurred at low temperature, while the polysaccharides were almost hydrolyzed to monosaccharide at high temperature. Under the optimum hydrolysis conditions (4 h, 1.5 mol/L trifluoroacetic acid, and 80 °C), Astragalus polysaccharides were hydrolyzed to characteristic oligosaccharide fragments. At last, a hydrophilic liquid chromatography-mass spectrometry method was used for the separation and structural characterization of the polysaccharide hydrolysates. The results showed that the resulting polysaccharides were mainly 1--> 4 linear glucan, and gluco-oligosaccharides with the degrees of polymerization (DP) of 4 - 11 were obtained after partial acid hydrolysis. The significance of this study is that it is the guidance for the characterization of other TCM polysaccharides.

  12. Liquid chromatography-mass spectrometry in occupational toxicology: a novel approach to the study of biotransformation of industrial chemicals.

    Science.gov (United States)

    Manini, Paola; Andreoli, Roberta; Niessen, Wilfried

    2004-11-26

    Biological monitoring and biomarkers are used in occupational toxicology for a more accurate risk assessment of occupationally exposed people. Appropriate and validated biomarkers of internal dose, like urinary metabolites, besides to be positively correlated with external exposure, have a predictive value to the risk of adverse effects. The application of liquid chromatography-mass spectrometry (LC-MS) in occupational and environmental toxicology, although relatively recent, has been demonstrated valid in the determination of traditional biomarkers of exposure, as well as in metabolism studies aimed at investigating minor metabolic routes and new more specific biomarkers. This review presents selected applications of LC-MS to the study of the metabolism of industrial chemicals, like n-hexane, benzene and other aromatic hydrocarbons, styrene and other monomers employed in plastic industry, as well as to other chemicals used in working environments, like pesticides used by farmers, and antineoplastic agents prepared by hospital personnel. Analytical and pre-analytical factors, which affect quantitative determination of urinary metabolites, i.e. sample preparation, matrix effect, ion suppression, use of internal standards, and calibration, are emphasized.

  13. Ultra performance liquid chromatography-mass spectrometry profiling of bile acid metabolites in biofluids: application to experimental toxicology studies.

    Science.gov (United States)

    Want, Elizabeth J; Coen, Muireann; Masson, Perrine; Keun, Hector C; Pearce, Jake T M; Reily, Michael D; Robertson, Donald G; Rohde, Cynthia M; Holmes, Elaine; Lindon, John C; Plumb, Robert S; Nicholson, Jeremy K

    2010-06-15

    We have developed an ultra performance liquid chromatography-mass spectrometry (UPLC-MS(E)) method to measure bile acids (BAs) reproducibly and reliably in biological fluids and have applied this approach for indications of hepatic damage in experimental toxicity studies. BAs were extracted from serum using methanol, and an Acquity HSS column coupled to a Q-ToF mass spectrometer was used to separate and identify 25 individual BAs within 5 min. Employing a gradient elution of water and acetonitrile over 21 min enabled the detection of a wide range of endogenous metabolites, including the BAs. The utilization of MS(E) allowed for characteristic fragmentation information to be obtained in a single analytical run, easily distinguishing glycine and taurine BA conjugates. The proportions of these conjugates were altered markedly in an experimental toxic state induced by galactosamine exposure in rats. Principally, taurine-conjugated BAs were greatly elevated ( approximately 50-fold from control levels), and were highly correlated to liver damage severity as assessed by histopathological scoring (r = 0.83), indicating their potential as a sensitive measure of hepatic damage. The UPLC-MS approach to BA analysis offers a sensitive and reproducible tool that will be of great value in exploring both markers and mechanisms of hepatotoxicity and can readily be extended to clinical studies of liver damage.

  14. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  15. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Jin; Shin, Yeon Jae; Oh, Se Yeon; Kim, Nam Sun; Kim, Kun; Lee, Dong Sun [Seoul Women' s University, Seoul (Korea, Republic of)

    2006-02-15

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (K{sub lh}) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

  16. Fast simultaneous analysis of caffeine, trigonelline, nicotinic acid and sucrose in coffee by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Perrone, Daniel; Donangelo, Carmen Marino; Farah, Adriana

    2008-10-15

    A rapid liquid chromatography-mass spectrometry method for the simultaneous quantification of caffeine, trigonelline, nicotinic acid and sucrose in coffee was developed and validated. The method involved extraction with hot water, clarification with basic lead acetate and membrane filtration, followed by chromatographic separation using a Spherisorb(®) S5 ODS2, 5μm chromatographic column and gradient elution with 0.3% aqueous formic acid/methanol at a flow rate of 0.2mL/min. The electrospray ionization source was operated in the negative mode to generate sucrose ions and in the positive mode to generate caffeine, trigonelline and nicotinic acid ions. Ionization suppression of all analytes was found due to matrix effect. Calibrations curves prepared in green and roasted coffee extracts were linear with r(2)>0.999. Roasted coffee was spiked and recoveries ranged from 93.0% to 105.1% for caffeine, from 85.2% to 116.2% for trigonelline, from 89.6% to 113.5% for nicotinic acid and from 94.1% to 109.7% for sucrose. Good repeatibilities (RSDcoffee samples (regular or decaffeinated green, ground roasted and instant) gave results in agreement with the literature. The method showed to be suitable for different types of coffee available in the market thus appearing as a fast and reliable alternative method to be used for routine coffee analysis. Copyright © 2008 Elsevier Ltd. All rights reserved.

  17. Liquid chromatography-mass spectrometry identification of anthocyanins of isla oca (Oxalis tuberosa, Mol.) tubers.

    Science.gov (United States)

    Alcalde-Eon, Cristina; Saavedra, Gloria; de Pascual-Teresa, Sonia; Rivas-Gonzalo, Julián C

    2004-10-29

    High-performance liquid chromatography (HPLC)-diode array detection (DAD)-mass spectrometry (MS) techniques have been successfully employed in the identification of the anthocyanins of the coloured tubers of isla oca (Oxalis tuberosa), the second most cultivated tuber in the Andean region. Tubers underwent a pre-treatment step in order to inhibit enzymatic reactions and to obtain a stable powder or "concentrate". This concentrate was dissolved, purified and then analysed. Eight different compounds were found. The major peaks were malvidin glucosides (malvidin 3-O-glucoside and 3,5-O-diglucoside). The rest of the peaks were 3,5-O-diglucosides of petunidin and peonidin, and 3-O-glucosides of delphinidin, petunidin and peonidin. Only malvidin 3-O-acetylglucoside-5-O-glucoside was found as an acylated anthocyanin.

  18. Mapping of low molecular weight heparins using reversed phase ion pair liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Daoyuan; Chi, Lequan; Jin, Lan; Xu, Xiaohui; Du, Xuzhao; Ji, Shengli; Chi, Lianli

    2014-01-01

    Low molecular weight heparins (LMWHs) are structurally complex, highly sulfated and negatively charged, linear carbohydrate polymers prepared by chemical or enzymatic depolymerization of heparin. They are widely used as anticoagulant drugs possessing better bioavailability, longer half-life, and lower side effects than heparin. Comprehensive structure characterization of LMWHs is important for drug quality assurance, generic drug application, and new drug research and development. However, fully characterization of all oligosaccharide chains in LMWHs is not feasible for current available analytical technologies due to their structure complexity and heterogeneity. Fingerprinting profiling is an efficient way for LMWHs' characterization and comparison. In this work, we present a simple, sensitive, and powerful analytical approach for structural characterization of LMWHs. Two different LMWHs, enoxaparin and nadroparin, were analyzed using reversed phase ion pair electrospray ionization mass spectrometry (RPIP-ESI-MS). More than 200 components were identified, including major structures, minor structures, and process related impurities. This approach is robust for high resolution and complementary fingerprinting analysis of LMWHs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Serum metabonomics of NAFLD plus T2DM based on liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yang; Li, Chunlong; Liu, Liyan; Guo, Fuchuan; Li, Songtao; Huang, Lina; Sun, Changhao; Feng, Rennan

    2016-09-01

    Nonalcoholic fatty liver disease (NAFLD), a main liver disease around the world, is closely associated with insulin resistance, type 2 diabetes mellitus (T2DM) and other metabolic diseases. The objective of this study is to identify distinct metabolites of NAFLD patients with or without T2DM. We used a biomarker-discovery population to find distinct metabolites of NAFLD patients with or without T2DM. Then, a validation population was applied to test the model of the biomarker-discovery population. All the individuals received anthropometric and common biochemical measurements. The metabolic data were analyzed by multivariable statistical analyses using ultra-high-performance liquid chromatography/quadrupole time-of-flight-tandem mass spectrometry. There were 7, 7, 2 metabolites in the positive electrospray ionization (ESI(+)) mode, which were identified between groups from both the biomarker-discovery and validation population. The NAFLD group showed higher concentrations of oleamide, l-phenylalanine, l-proline, bilirubin, l-palmitoylcarnitine, and PC (20:5) and a lower concentration of Lyso-PAF C-18 than those of control. Compared with the control group, the NAFLD+T2DM group displayed higher oleamide, l-leucine, LysoPC (14:0), bilirubin, tetradecenoylcarnitine, linoleyl carnitine, and tetradecadiencarnitine in serum. Tetradecenoylcarnitine and tetradecadiencarnitine were more elevated in patients with NAFLD+T2DM than in the NAFLD group. Serum metabonomic analyses displayed great metabolic changes in patients with NAFLD and NAFLD plus T2DM. Our study is beneficial in providing a further view into the pathogenesis and pathophysiology of NAFLD and NAFLD plus T2DM, which might be useful for the prevention and therapy of NAFLD and NAFLD plus T2DM. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Degradation product characterization of therapeutic oligonucleotides using liquid chromatography mass spectrometry.

    Science.gov (United States)

    Elzahar, N M; Magdy, N; El-Kosasy, Amira M; Bartlett, Michael G

    2018-05-01

    Synthetic antisense phosphorothioate oligonucleotides (PS) have undergone rapid development as novel therapeutic agents. The increasing significance of this class of drugs requires significant investment in the development of quality control methods. The determination of the many degradation pathways of such complex molecules presents a significant challenge. However, an understanding of the potential impurities that may arise is necessary to continue to advance these powerful new therapeutics. In this study, four different antisense oligonucleotides representing several generations of oligonucleotide therapeutic agents were evaluated under various stress conditions (pH, thermal, and oxidative stress) using ion-pairing reversed-phase liquid chromatography tandem mass spectrometry (IP-RPLC-MS/MS) to provide in-depth characterization and identification of the degradation products. The oligonucleotide samples were stressed under different pH values at 45 and 90 °C. The main degradation products were observed to be losses of nucleotide moieties from the 3'- and 5'-terminus, depurination, formation of terminal phosphorothioates, and production of ribose, ribophosphorothioates (Rp), and phosphoribophosphorothioates (pRp). Moreover, the effects of different concentrations of hydrogen peroxide were studied resulting in primarily extensive desulfurization and subsequent oxidation of the phosphorothioate linkage to produce the corresponding phosphodiester. The reaction kinetics for the degradation of the oligonucleotides under the different stress conditions were studied and were found to follow pseudo-first-order kinetics. Differences in rates exist even for oligonucleotides of similar length but consisting of different sequences. Graphical abstract Identification of degradation products across several generations of oligonucleotide therapeutics using LC-MS.

  1. Quantification of almond skin polyphenols by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bolling, Bradley W; Dolnikowski, Gregory; Blumberg, Jeffrey B; Oliver Chen, C Y

    2009-01-01

    Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic acids from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-day relative standard deviation (RSD) of standard curve slopes ranged from 13% to 25% of the mean. On column (OC) limits of detection (LOD) for polyphenols ranged from 0.013 to 1.4 pmol, and flavonoid glycosides had a 7-fold greater sensitivity than aglycones. Limits of quantification were 0.043 to 2.7 pmol OC, with a mean of 0.58 pmol flavonoid OC. Mean inter-day RSD of polyphenols in almond skin extract was 6.8% with a range of 4% to 11%, and intra-day RSD was 2.4%. Liquid nitrogen (LN(2)) or hot water (HW) blanching was used to facilitate removal of the almond skins prior to extraction using assisted solvent extraction (ASE) or steeping with acidified aqueous methanol. Recovery of polyphenols was greatest in HW blanched almond extracts with a mean value of 2.1 mg/g skin. ASE and steeping extracted equivalent polyphenols, although ASE of LN(2) blanched skins yielded 52% more aglycones and 23% less flavonoid glycosides. However, the extraction methods did not alter flavonoid profile of HW blanched almond skins. The recovery of polyphenolic components that were spiked into almond skins before the steeping extraction was 97% on a mass basis. This LC-MS method presents a reliable means of quantifying almond polyphenols.

  2. Recent advances and trends in the liquid-chromatography-mass spectrometry analysis of flavonoids.

    Science.gov (United States)

    de Villiers, André; Venter, Pieter; Pasch, Harald

    2016-01-22

    Flavonoids have elicited significant attention as a result of their importance in plants, their influence on the properties of natural-product derived commodities and especially as a consequence of their purported health benefits. Research in all of these fields relies heavily on accurate analytical data, and in this LC-MS has come to play an influential role by allowing relatively fast tentative identification and accurate quantification of low levels of flavonoids in a variety of matrices. The field has undergone rapid expansion in the last decade due to important developments in both HPLC and MS instrumentation, which nowadays allow much faster and more accurate analysis of flavonoids. This contribution aims to provide an overview of these developments and their application in flavonoid analysis since 2009. The discussion is focussed first on methodologies which provide improved LC separation of flavonoids in terms of speed and/or resolution, including ultra high pressure LC (UHPLC), monolithic and superficially porous phases, high temperature LC (HTLC) and comprehensive two-dimensional LC (LC×LC). The fundamental background relevant to each of these will be briefly outlined, as well as the implications and promise of their hyphenation to MS. Secondly, the possibilities and limitations of a range of the latest MS instruments available in combination with advanced LC analysis will be discussed, including ion trap, triple quadrupole, time-of-flight, Orbitrap, ion mobility and various hybrid instruments. Examples from the latest literature will be used to illustrate the performance gains achievable in flavonoid analysis by the hyphenation of advanced LC separation and high-end MS instrumentation. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  4. Tailored liquid chromatography-mass spectrometry analysis improves the coverage of the intracellular metabolome of HepaRG cells.

    Science.gov (United States)

    Cuykx, Matthias; Negreira, Noelia; Beirnaert, Charlie; Van den Eede, Nele; Rodrigues, Robim; Vanhaecke, Tamara; Laukens, Kris; Covaci, Adrian

    2017-03-03

    Metabolomics protocols are often combined with Liquid Chromatography-Mass Spectrometry (LC-MS) using mostly reversed phase chromatography coupled to accurate mass spectrometry, e.g. quadrupole time-of-flight (QTOF) mass spectrometers to measure as many metabolites as possible. In this study, we optimised the LC-MS separation of cell extracts after fractionation in polar and non-polar fractions. Both phases were analysed separately in a tailored approach in four different runs (two for the non-polar and two for the polar-fraction), each of them specifically adapted to improve the separation of the metabolites present in the extract. This approach improves the coverage of a broad range of the metabolome of the HepaRG cells and the separation of intra-class metabolites. The non-polar fraction was analysed using a C18-column with end-capping, mobile phase compositions were specifically adapted for each ionisation mode using different co-solvents and buffers. The polar extracts were analysed with a mixed mode Hydrophilic Interaction Liquid Chromatography (HILIC) system. Acidic metabolites from glycolysis and the Krebs cycle, together with phosphorylated compounds, were best detected with a method using ion pairing (IP) with tributylamine and separation on a phenyl-hexyl column. Accurate mass detection was performed with the QTOF in MS-mode only using an extended dynamic range to improve the quality of the dataset. Parameters with the greatest impact on the detection were the balance between mass accuracy and linear range, the fragmentor voltage, the capillary voltage, the nozzle voltage, and the nebuliser pressure. By using a tailored approach for the intracellular HepaRG metabolome, consisting of three different LC techniques, over 2200 metabolites can be measured with a high precision and acceptable linear range. The developed method is suited for qualitative untargeted LC-MS metabolomics studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  6. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells.

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-05-01

    145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry.

  7. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-01-01

    g/mL). All other extracts were nontoxic. A total of 145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. Conclusions: The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. SUMMARY Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. PMID:27279705

  8. Exploring symbiotic nitrogen fixation and assimilation in pea root nodules by in vivo 15N nuclear magnetic resonance spectroscopy and liquid chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Scharff, A.M.; Egsgaard, H.; Hansen, P.E.

    2003-01-01

    Nitrogen (N) fixation and assimilation in pea (Pisum sativum) root nodules were studied by in vivo N-15 nuclear magnetic resonance (NMR) by exposing detached nodules to N-15, via a perfusion medium, while recording a time course of spectra. In vivo P-31 NMR spectroscopy was used to monitor...... the physiological state of the metabolically active nodules. The nodules were extracted after the NMR studies and analyzed for total soluble amino acid pools and N-15 labeling of individual amino acids by liquid chromatography-mass spectrometry. A substantial pool of free ammonium was observed by N-15 NMR...... labeling of Asn was observed by liquid chromatography-mass spectrometry, which is consistent with the generally accepted role of Asn as the end product of primary N assimilation in pea nodules. However, the Asn N-15 amino signal was absent in in vivo N-15 NMR spectra, which could be because...

  9. Analysis of human plasma metabolites across different liquid chromatography/mass spectrometry platforms: Cross-platform transferable chemical signatures.

    Science.gov (United States)

    Telu, Kelly H; Yan, Xinjian; Wallace, William E; Stein, Stephen E; Simón-Manso, Yamil

    2016-03-15

    The metabolite profiling of a NIST plasma Standard Reference Material (SRM 1950) on different liquid chromatography/mass spectrometry (LC/MS) platforms showed significant differences. Although these findings suggest caution when interpreting metabolomics results, the degree of overlap of both profiles allowed us to use tandem mass spectral libraries of recurrent spectra to evaluate to what extent these results are transferable across platforms and to develop cross-platform chemical signatures. Non-targeted global metabolite profiles of SRM 1950 were obtained on different LC/MS platforms using reversed-phase chromatography and different chromatographic scales (conventional HPLC, UHPLC and nanoLC). The data processing and the metabolite differential analysis were carried out using publically available (XCMS), proprietary (Mass Profiler Professional) and in-house software (NIST pipeline). Repeatability and intermediate precision showed that the non-targeted SRM 1950 profiling was highly reproducible when working on the same platform (relative standard deviation (RSD) HPLC, UHPLC and nanoLC) on the same platform. A substantial degree of overlap (common molecular features) was also found. A procedure to generate consistent chemical signatures using tandem mass spectral libraries of recurrent spectra is proposed. Different platforms rendered significantly different metabolite profiles, but the results were highly reproducible when working within one platform. Tandem mass spectral libraries of recurrent spectra are proposed to evaluate the degree of transferability of chemical signatures generated on different platforms. Chemical signatures based on our procedure are most likely cross-platform transferable. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  10. Liquid chromatography/mass spectrometry investigation of the impact of thermal processing and storage on peach procyanidins.

    Science.gov (United States)

    Hong, Yun-Jeong; Barrett, Diane M; Mitchell, Alyson E

    2004-04-21

    Normal-phase liquid chromatography/mass spectrometry (LC/MS) was used to determine the levels and fate of procyanidins in frozen and canned Ross clingstone peaches as well as in the syrup used in the canning over a 3 month period. Procyanidin oligomers, monomers through undecamers, were identified in Ross clingstone peaches. Optimized methods allowed for the quantitation of oligomers through octamers. The profile of procyanidins in peaches is similar to profiles found in grapes, chocolate, and beverages linked to health benefits such as tea and wine. The monomer content in frozen peeled peaches was found to be 19.59 mg/kg. Dimers (39.59 mg/kg) and trimers (38.81 mg/kg) constituted the largest percent composition of oligomers in the peaches. Tetramers through octamers were present in levels of 17.81, 12.43, 10.62, 3.94 and 1.75 mg/kg, respectively. Thermal processing resulted in an 11% reduction in monomers, a 9% reduction in dimers, a 12% reduction in trimers, a 6% reduction in tetramers, and a 5% reduction in pentamers. Hexamers and heptamers demonstrated an approximate 30% loss, and octamers were no longer detected. Analysis of the syrup after thermal processing indicates that there is a migration of procyanidin monomers through hexamers into the syrup that can account for the losses observed during the canning process. Storage of canned peaches for 3 months demonstrated a time-related loss in higher oligomers and that by 3 months oligomers larger than tetramers are not observed. At 3 months postcanning, levels of monomers had decreased by 10%, dimers by 16%, trimers by 45%, and tetramers by 80%. A similar trend was observed in the canning syrup.

  11. A Search for Amino Acids and Nucleobases in the Martian Meteorite Roberts Massif 04262 Using Liquid Chromatography-Mass Spectrometry

    Science.gov (United States)

    Callahan, Michael P.; Burton, Aaron S.; Elsila, Jamie E.; Baker, Eleni M.; Smith, Karen E.; Glavin, Daniel P.; Dworkin, Jason P.

    2013-01-01

    The investigation into whether Mars contains signatures of past or present life is of great interest to science and society. Amino acids and nucleobases are compounds that are essential for all known life on Earth and are excellent target molecules in the search for potential Martian biomarkers or prebiotic chemistry. Martian meteorites represent the only samples from Mars that can be studied directly in the laboratory on Earth. Here, we analyzed the amino acid and nucleobase content of the shergottite Roberts Massif (RBT) 04262 using liquid chromatography-mass spectrometry. We did not detect any nucleobases above our detection limit in formic acid extracts; however, we did measure a suite of protein and nonprotein amino acids in hot-water extracts with high relative abundances of beta-alanine and gamma-amino-eta-butyric acid. The presence of only low (to absent) levels of several proteinogenic amino acids and a lack of nucleobases suggest that this meteorite fragment is fairly uncontaminated with respect to these common biological compounds. The distribution of straight-chained amine-terminal eta-omega-amino acids in RBT 04262 resembled those previously measured in thermally altered carbonaceous meteorites. A carbon isotope ratio of -24(0/00) +/- 6(0/00) for beta-alanine in RBT 04262 is in the range of reduced organic carbon previously measured in Martian meteorites (Steele et al. 2012). The presence of eta-omega-amino acids may be due to a high temperature Fischer-Tropschtype synthesis during igneous processing on Mars or impact ejection of the meteorites from Mars, but more experimental data are needed to support these hypotheses.

  12. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins

    International Nuclear Information System (INIS)

    Tang, Yanan; Li, Liang

    2013-01-01

    Graphical abstract: -- Highlights: •LC–MS was developed for quantifying protein mixtures containing both intact and N-terminal truncated proteins. • 12 C 2 -Dansylation of the N-terminal amino acid of proteins was done first, followed by microwave-assisted acid hydrolysis. •The released 12 C 2 -dansyl labeled N-terminal amino acid was quantified using 13 C 2 -dansyl labeled amino acid standards. •The method provided accurate and precise results for quantifying intact and N-terminal truncated proteins within 8 h. -- Abstract: The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards

  13. Plasma metabonomics study of the patients with acute anterior uveitis based on ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Guo, Junguo; Yan, Tingqin; Bi, Hongsheng; Xie, Xiaofeng; Wang, Xingrong; Guo, Dadong; Jiang, Haiqiang

    2014-06-01

    The identification of the biomarkers of patients with acute anterior uveitis (AAU) may allow for a less invasive and more accurate diagnosis, as well as serving as a predictor in AAU progression and treatment response. The aim of this study was to identify the potential biomarkers and the metabolic pathways from plasma in patients with AAU. Both plasma metabolic biomarkers and metabolic pathways in the AAU patients versus healthy volunteers were investigated using ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) and a metabonomics approach. The principal component analysis (PCA) was used to separate AAU patients from healthy volunteers as well as to identify the different biomarkers between the two groups. Metabolic compounds were matched to the KEGG, METLIN, and HMDB databases, and metabolic pathways associated with AAU were identified. The PCA for UPLC-MS data shows that the metabolites in AAU patients were significantly different from those of healthy volunteers. Of the 4,396 total features detected by UPLC-MS, 102 features were significantly different between AAU patients and healthy volunteers according to the variable importance plot (VIP) values (greater than two) of partial least squares discriminate analysis (PLS-DA). Thirty-three metabolic compounds were identified and were considered as potential biomarkers. Meanwhile, ten metabolic pathways were found that were related to the AAU according to the identified biomarkers. These data suggest that metabolomics study can identify potential metabolites that differ between AAU patients and healthy volunteers. Based on the PCA, PLS-DA, several potential metabolic biomarkers and pathways in AAU patients were found and identified. In addition, the UPLC-MS technique combined with metabonomics could be a suitable systematic biology tool in research in clinical problems in ophthalmology, and can provide further insight into the pathophysiology of AAU.

  14. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.

    Science.gov (United States)

    Nah, Hyunjin; Lee, Sang-Guk; Lee, Kyeong-Seob; Won, Jae-Hee; Kim, Hyun Ok; Kim, Jeong-Ho

    2016-02-01

    The aim of this study was to estimate bilirubin interference and accuracy of six routine methods for measuring creatinine compared with isotope dilution-liquid chromatography mass spectrometry (ID-LC/MS). A total of 40 clinical serum samples from 31 patients with serum total bilirubin concentration >68.4μmol/L were collected. Serum creatinine was measured using two enzymatic reagents and four Jaffe reagents as well as ID-LC/MS. Correlations between bilirubin concentration and percent difference in creatinine compared with ID-LC/MS were analyzed to investigate bilirubin interference. Bias estimations between the six reagents and ID-LC/MS were performed. Recovery tests using National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967a were also performed. Both the enzymatic methods showed no bilirubin interference. However, three of the four Jaffe methods demonstrated significant bilirubin concentration-dependent interference in samples with creatinine levels creatinine levels ranging from 53.0 to 97.2μmol/L. Comparison of these methods with ID-LC/MS using patients' samples with elevated bilirubin revealed that the tested methods failed to achieve the bias goal at especially low levels of creatinine. In addition, recovery test using NIST SRM 967a showed that bias in one Jaffe method and two enzymatic methods did not achieve the bias goal at either low or high level of creatinine, indicating they had calibration bias. One enzymatic method failed to achieve all the bias goals in both comparison experiment and recovery test. It is important to understand that both bilirubin interference and calibration traceability to ID-LC/MS should be considered to improve the accuracy of creatinine measurement. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yanan; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2013-08-20

    Graphical abstract: -- Highlights: •LC–MS was developed for quantifying protein mixtures containing both intact and N-terminal truncated proteins. •{sup 12}C{sub 2}-Dansylation of the N-terminal amino acid of proteins was done first, followed by microwave-assisted acid hydrolysis. •The released {sup 12}C{sub 2}-dansyl labeled N-terminal amino acid was quantified using {sup 13}C{sub 2}-dansyl labeled amino acid standards. •The method provided accurate and precise results for quantifying intact and N-terminal truncated proteins within 8 h. -- Abstract: The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards.

  17. Determination of phenobarbital in hair matrix by liquid phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Roveri, Flávia Lopes; Paranhos, Beatriz Aparecida Passos Bismara; Yonamine, Mauricio

    2016-08-01

    A method for identification and quantification of phenobarbital in hair samples by liquid phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS) has been presented. Drug-free hair specimens were collected and separated in 50mg aliquots. Each aliquot was washed with 2.0mL of dichloromethane for 15min at 37°C. Standards and deuterated internal standards for calibration and quality control samples were added to the washed hair aliquot and the sample was submitted to complete digestion with sodium hydroxide (NaOH) 1.0mol/L for 15min at 70°C. The dissolved sample was submitted to LPME. After extraction, the residue was derivatized with tetramethylammonium hydroxide (TMAH) and analyzed by GC-MS. The limit of detection (LOD) was 0.1ng/mg and the limit of quantification (LOQ) was 0.25ng/mg. The calibration curve was linear over a concentration range of 0.25ng/mg to 10ng/mg (r(2)>0.99). The intra- and inter-assay precisions, given by RSD, were less than 6% for phenobarbital. Fortified samples of secobarbital and pentobarbital were also submitted to the validated method. The method was successfully applied to hair samples collected from three volunteers who reported regular use of phenobarbital (clinical treatment). The concentrations found were 9.5, 15.1 and 16.3ng/mg of phenobarbital. To contemplate the concentrations found, dilution integrity tests were also validated. The LPME and GC-MS method showed to be suitable for the detection of phenobarbital in hair samples and can be promptly used for different purposes whenever required. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Rapid simultaneous determination of organophosphorus pesticides in human serum and urine by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Zlatković Milica

    2010-01-01

    Full Text Available Background/Aim. Analysis of organophosphosphorus compounds and their metabolites in a biological material includes the use of numerous methods, covering both preparation of samples for analysis and their identification that is considered to be very complex. Low concentrations monitoring requires implementation of highly sensitive analytical techniques. The aim of this study was to develop and validate an original and sensitive method for the detection and quantitation of organophosphorus pesticides (dimethoate, diazinon, malathion and malaoxon in human biological matrices (serum, urine. Methods. This method was based on a solid-phase extraction procedure, a chromatographic separation using an ACQUITY UPLC ® HSST3 column and mass spectrometric detection in the positve ion mode. Mobile phase: was consited of Solvent A (5 mM ammonium formate pH 3.0 and Solvent B (0.1% acetic formate in methanol, in a linear gradient (constant flow-rate 0.3 mL/min. Results. The standard curve was linear in the range of 0.05-5.00 mg/L for malathion and malaoxon, 0.10-5.00 mg/L for dimethoate and 0.05-2.50 mg/L for diazinon. The correlation coefficient was r ≥ 0.99. Extraction recoveries were satisfactory and ranged between 90-99%. The limits of detection (LOD was between 0.007- 0.07 mg/L and the limits of quantitation (LOQ ranged between 0.022-0.085 mg/L. Intra- and interassay precision and accuracy were satisfactory for all of the pesticides analyzed. Conclusion. The method of liquid chromatography - mass spectrometry is simple, accurate, and useful for the determination of organophosphorus pesticides in both clinical and forensic toxicology.

  19. Gas chromatography-mass spectrometry and high-performance liquid chromatographic analyses of thermal degradation products of common plastics

    NARCIS (Netherlands)

    Pacakova, V.; Leclercq, P.A.

    1991-01-01

    The thermo-oxidation of five commonly used materials, namely low-density polyethylene, retarded polyethylene, paper with a polyethylene foil, a milk package and filled polypropylene, was studied. Capillary gas chromatography and gas chromatography-mass spectrometry were used to analyze the volatile

  20. Pressurized liquid extraction-gas chromatography-mass spectrometry analysis of fragrance allergens, musks, phthalates and preservatives in baby wipes.

    Science.gov (United States)

    Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria

    2015-03-06

    Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between

  1. Use of radioimmunoassay as a screen for antibiotics in confined animal feeding operations and confirmation by liquid chromatography/mass spectrometry

    Science.gov (United States)

    Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.

    2000-01-01

    Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid

  2. [Determination of fatty acid esters of chloropropanediols in diet samples by gas chromatography-mass spectrometry coupled with solid-supported liquid-liquid extraction].

    Science.gov (United States)

    Gao, Jie; Liu, Qing; Han, Feng; Miao, Hong; Zhao, Yunfeng; Wu, Yongning

    2014-05-01

    To establish a method for the determination of fatty acid esters of 3-monochloropropane-1, 2-diol (3-MCPD) and 2-monochloropropane-1, 3-diol (2-MCPD) in diet samples by gas chromatography-mass spectrometry (GC-MS) with solid-supported liquid-liquid extraction (SLE). Diet samples were ultrasonically extracted by hexane, followed by ester cleavage reaction with sodium methylate in methanol, and then purified by solid-supported liquid-liquid extraction. (SLE) using diatomaceous earth as the sorbent. After derivatization with heptafluorobutyrylimidazole, the analytes were detected by GC-MS and quantified by the deuterated internal standards. The limits of detection (LODs) of 3-MCPD esters and 2-MCPD esters in different diet samples were 0.002 - 0.005 mg/kg and 0.002 - 0.006 mg/kg. The average recoveries of 3-MCPD esters and 2-MCPD esters at the spiking levels of 0.05 and 0.1 mg/kg in the diet samples were in the range of 65.9% - 104.2% and 75.4% - 118.0%, respectively, with the relative standard deviations in the range of 2.2% - 14.2% and 0.8% - .13.9%. The method is simple, accurate and rugged for the determination of fatty acid esters of 3-MCPD and 2-MCPD in diet samples.

  3. Liquid chromatography-mass spectrometry for metabolic footprinting of co-cultures of lactic and propionic acid bacteria

    DEFF Research Database (Denmark)

    Honore, Anders H.; Thorsen, Michael; Skov, Thomas

    2013-01-01

    (UPLC) coupled to high-resolution mass spectrometry (MS) via electrospray ionisation (ESI) operated in both positive and negative modes is regarded as the optimum instrumental technique. The applicability of a range of liquid chromatographic techniques ranging from ion-pair (IPC) and hydrophilic...... could be a potent approach to elucidation of the mechanism. The purpose of this review is to discuss the two pre-requisites for such a study-the compound classes expected in the co-cultures, and on the basis of these, the most suitable analytical technique(s). Ultrahigh-performance liquid chromatography...

  4. A simple liquid extraction protocol for overcoming the ion suppression of triacylglycerols by phospholipids in liquid chromatography mass spectrometry studies.

    Science.gov (United States)

    Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu

    2016-02-01

    It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Mercapturic acids: recent advances in their determination by liquid chromatography/mass spectrometry and their use in toxicant metabolism studies and in occupational and environmental exposure studies

    Science.gov (United States)

    Mathias, Patricia I.; B’Hymer, Clayton

    2016-01-01

    This review describes recent selected HPLC/MS methods for the determination of urinary mercapturates that are useful as non-invasive biomarkers in characterizing human exposure to electrophilic industrial chemicals in occupational and environmental studies. High performance liquid chromatography/mass spectrometry is a sensitive and specific method for analysis of small molecules found in biological fluids. In this review, recent selected mercapturate quantification methods are summarized and specific cases are presented. The biological formation of mercapturates is introduced and their use indicators of metabolic processing of reactive toxicants is discussed, as well as future trends and limitations in this area of research. PMID:26900903

  6. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  7. Analyses of Indole Compounds in Sugar Cane (Saccharum officinarum L. Juice by High Performance Liquid Chromatography and Liquid Chromatography-Mass Spectrometry after Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Jean Wan Hong Yong

    2017-03-01

    Full Text Available Simultaneous quantitative analysis of 10 indole compounds, including indole-3-acetic acid (IAA, one of the most important naturally occurring auxins and some of its metabolites, by high performance liquid chromatography (HPLC and liquid chromatography-mass spectrometry (LC-MS after solid-phase extraction (SPE was reported for the first time. The analysis was carried out using a reverse phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid modified by methanol. Furthermore, a novel SPE procedure was developed for the pre-concentration and purification of indole compounds using C18 SPE cartridges. The combination of SPE, HPLC, and LC-MS was applied to screen for the indole compounds present in sugar cane (Saccharum officinarum L. juice, a refreshing beverage with various health benefits. Finally, four indole compounds were successfully detected and quantified in sugar cane juice by HPLC, which were further unequivocally confirmed by LC-MS/MS experiments operating in the multiple reaction monitoring (MRM mode.

  8. Optimization of two different dispersive liquid-liquid microextraction methods followed by gas chromatography-mass spectrometry determination for polycyclic aromatic hydrocarbons (PAHs) analysis in water.

    Science.gov (United States)

    Tseng, Wan-Chi; Chen, Pai-Shan; Huang, Shang-Da

    2014-03-01

    Novel sample preparation methods termed "up-and-down shaker-assisted dispersive liquid-liquid microextraction (UDSA-DLLME)" and "water with low concentration of surfactant in dispersed solvent-assisted emulsion dispersive liquid-liquid microextraction (WLSEME)" coupled with gas chromatography-mass spectrometry (GC-MS) have been developed for the analysis of 11 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. For UDSA-DLLME, an up-and-down shaker-assisted emulsification was employed. Extraction was complete in 3min. Only 14 μL of 1-heptanol was required, without a dispersive solvent. Under the optimum conditions, the linear range was 0.08-100 µg L(-1), and the LODs were in the range 0.022-0.060 µg L(-1). The enrichment factors (EFs) ranged from 392 to 766. Relative recoveries were between 84% and 113% for river, lake, and field water. In WLSEME, 9 μL of 1-nonanol as extraction solvent and 240 μL of 1 mg L(-1) Triton X-100 as surfactant were mixed in a microsyringe to form a cloudy emulsified solution, which was then injected into the samples. Compared with other surfactant-assisted emulsion methods, WLSEME uses much less surfactant. The linear range was 0.08-100 µg L(-1), and the LODs were 0.022-0.13 µg L(-1). The EFs ranged from 388 to 649. The relative recoveries were 86-114% for all three water specimens. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Glyoxal and methylglyoxal as urinary markers of diabetes. Determination using a dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pastor-Belda, M; Fernández-García, A J; Campillo, N; Pérez-Cárceles, M D; Motas, M; Hernández-Córdoba, M; Viñas, P

    2017-08-04

    Glyoxal (GO) and methylglyoxal (MGO) are α-oxoaldehydes that can be used as urinary diabetes markers. In this study, their levels were measured using a sample preparation procedure based on salting-out assisted liquid-liquid extraction (SALLE) and dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography-mass spectrometry (GC-MS). The effect of the derivatization reaction with 2,3-diaminonaphthalene, the addition of acetonitrile and sodium chloride to urine, and the DLLME step using the acetonitrile extract as dispersant solvent and carbon tetrachloride as extractant solvent were carefully optimized. Quantification was performed by the internal standard method, using 5-bromo-2-chloroanisole. The intraday and interday precisions were lower than 6%. Limits of detection were 0.12 and 0.06ngmL -1 , and enrichment factors 140 and 130 for GO and MGO, respectively. The concentrations of these α-oxoaldehydes in urine were between 0.9 and 35.8ngg -1 levels (creatinine adjusted). A statistical comparison of the analyte contents of urine samples from non-diabetic and diabetic patients pointed to significant differences (P=0.046, 24 subjects investigated), particularly regarding MGO, which was higher in diabetic patients. The novelty of this study compared with previous procedures lies in the treatment of the urine sample by SALLE based on the addition of acetonitrile and sodium chloride to the urine. The DLLME procedure is performed with a sedimented drop of the extractant solvent, without a surfactant reagent, and using acetonitrile as dispersant solvent. Separation of the analytes was performed using GC-MS detection, being the analytes unequivocal identified. The proposed procedure is the first microextraction method applied to the analysis of urine samples from diabetic and non-diabetic patients that allows a clear differentiation between both groups using a simple analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Investigation of forced and total degradation products of amlodipine besylate by liquid chromatography and liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Stoiljković Zora Ž.

    2014-01-01

    Full Text Available An isocratic, reversed-phase liquid chromatographic method was applied for the investigation of the degradation products of amlodipine besylate under the stressed conditions in solution. Amlodipine besylate stock solutions were subjected to acid and alkali hydrolysis, chemical oxidation and photodegradation as well as to the electrochemical degradation by cyclic voltammetry in 0.05 mol/L NaHCO3 on gold electrode. The total degradation of amlodipine besylate was achieved in 5 mol/L NaOH at 80°C for 6 h and the compound with molecular formula C15H16NOCl was identified as a main degradation product. Under acidic (5 mol/L HCl at 80°C for 6 h stress conditions 75.2% of amlodipine besylate degradation was recorded. Oxidative degradation in the solution of 3% H2O2-methanol 80:20 at 80°C for 6 h showed that amlodipine besylate degraded to 80.1%. After 14 days of expose in photostability chamber amlodipine besylate solution showed degradation of 32.2%. In electrochemical degradation after 9 hours of cyclization the beginning of amlodipine oxidation was shifted for 200 mV to more negative potentials, with the degradation of 66.5%. Mass spectrometry analysis confirmed the presence of dehydro amlodipine derivate with molecular formula C20H23N2O5Cl in oxidative and acidic conditions while in electrochemical degradation was detected in traces. [Projekat Ministarsva nauke Republike Srbije, br. 172013

  11. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  12. Gas chromatography-mass spectrometry of ethyl palmitate calibration and resolution with ethyl oleate as biomarker ethanol sub acute in urine application study

    Science.gov (United States)

    Suaniti, Ni Made; Manurung, Manuntun

    2016-03-01

    Gas Chromatography-Mass Spectrometry is used to separate two and more compounds and identify fragment ion specific of biomarker ethanol such as palmitic acid ethyl ester (PAEE), as one of the fatty acid ethyl esters as early detection through conyugated reaction. This study aims to calibrate ethyl palmitate and develop analysis with oleate acid. This methode can be used analysis ethanol and its chemistry biomarker in ethanol sub-acute consumption as analytical forensic toxicology. The result show that ethanol level in urine rats Wistar were 9.21 and decreased 6.59 ppm after 48 hours consumption. Calibration curve of ethyl palmitate was y = 0.2035 x + 1.0465 and R2 = 0.9886. Resolution between ethyl palmitate and oleate were >1.5 as good separation with fragment ion specific was 88 and the retention time was 18 minutes.

  13. Salting-out assisted liquid-liquid extraction combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in high salinity and biological samples.

    Science.gov (United States)

    Niu, Zongliang; Yu, Chunwei; He, Xiaowen; Zhang, Jun; Wen, Yingying

    2017-09-05

    A salting-out assisted liquid-liquid extraction (SALLE) combined with gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of four pyrethroid insecticides (PYRs) in high salinity and biological samples. Several parameters including sample pH, salting-out solution volume and salting-out solution pH influencing the extraction efficiency were systematically investigated with the aid of orthogonal design. The optimal extraction conditions of SALLE were: 4mL of salting-out solution with pH=4 and the sample pH=3. Under the optimum extraction and determination conditions, good responses for four PYRs were obtained in a range of 5-5000ng/mL, with linear coefficients greater than 0.998. The recoveries of the four PYRs ranged from 74% to 110%, with standard deviations ranging from 1.8% to 9.8%. The limits of detection based on a signal-to-noise ratio of 3 were between 1.5-60.6ng/mL. The method was applied to the determination of PYRs in urine, seawater and wastewater samples with a satisfactory result. The results demonstrated that this SALLE-GC-MS method was successfully applied to determine PYRs in high salinity and biological samples. SALLE avoided the need for the elimination of salinity and protein in the sample matrix, as well as clean-up of the extractant. Most of all, no centrifugation or any special apparatus are required, make this a promising method for rapid sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  15. Quantitative Analysis of Tetramethylenedisulfotetramine ('Tetramine') Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    International Nuclear Information System (INIS)

    Owens, J.; Hok, S.; Alcaraz, A.; Koester, C.

    2008-01-01

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD 50 = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 (micro)g/mL by LC/MS/MS versus 0.15 (micro)g/mL for GC/MS. Fortifications of the beverages at 2.5 (micro)g/mL and 0.25 (micro)g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  16. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography.

    Science.gov (United States)

    Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.

  17. Use of [18O4] phosphoric acid in the quantitation of phosphate by gas-liquid chromatography-mass spectrometry analysis

    International Nuclear Information System (INIS)

    Graff, G.; Krick, T.P.; Walseth, T.F.; Goldberg, N.D.

    1980-01-01

    A procedure is described to quantitate inorganic phosphate in the form of the tris(trimethylsilyl) (TMS) phosphate by gas-liquid chromatography-mass spectrometry (glc-ms) that increases the previously reported detection limit from the microgram to the nanogram range. The sensitivity for detecting TMS-phosphate by glc-ms analysis was shown to be limited by an increasing fractional loss with decreasing concentrations of TMS-phosphate analyzed due to its adsorption on different types of glc column supports. The method developed employs [ 18 O 4 ] phosphoric acid which serves as both an internal standard to permit quantitation and as a carrier to minimize sample adsorption on the glc column support

  18. Determination of nitrosamines and caffeine metabolites in wastewaters using gas chromatography mass spectrometry and ionic liquid stationary phases.

    Science.gov (United States)

    Reyes-Contreras, Carolina; Domínguez, Carmen; Bayona, Josep M

    2012-10-26

    Recently, the interest to assess the environmental and human health effects of a wide group of emerging contaminants is growing worldwide. However, one of the main problems associated to their exposure is their determination in environmental matrices. It is hindered by the high polarity of most of these analytes, the poor selectivity obtained with low polarity stationary phases and the high background obtained with polar columns commonly used in GC-MS. Accordingly, this study examines the suitability of ionic liquid (IL) (e.g. SLB-IL59, SLB-IL61, SLB-IL82 and SLB-IL111) as stationary phases for GC-MS and their application to the determination of nitrosamines and caffeine metabolites in wastewater samples. Different chromatographic conditions were evaluated and results discussed in terms of resolution and peak symmetry. The SLB-IL111 column enabled the baseline separation and quantification of 7 nitrosamines in a shorter analysis time compared with cyanopropylphenyl polysiloxane commonly used. On the other hand, the SLB-IL59 column provided the best results for caffeine metabolites. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  20. Acamprosate determinations in plasma and cerebrospinal fluid after multiple dosing measured by liquid chromatography-mass spectroscopy: a pharmacokinetic study in healthy volunteers.

    Science.gov (United States)

    Hammarberg, Anders; Beck, Olof; Eksborg, Staffan; Jayaram-Lindström, Nitya; Lindefeldt, Annika; Andersson, Maria; Brundin, Lou; Reid, Malcolm S; Franck, Johan

    2010-08-01

    The central nervous system-active medication acamprosate has been shown to modulate alcohol-related behavior in both preclinical and clinical studies. Although commonly used in the treatment of alcohol dependence, there are still unanswered questions concerning the pharmacokinetic properties of acamprosate. The aims of the present study were to 1) to validate liquid chromatography-mass spectrometry as a method to study the presence of acamprosate in plasma and cerebrospinal fluid (CSF) in humans; and 2) validate previous results on clinically important pharmacokinetic data for acamprosate. In an open label, single-site design, 13 healthy males and females were recruited to 22 days of oral acamprosate treatment (1998 mg/day). Subjects provided in all 256 plasma samples for analysis at regular intervals at Day 1, 7, 14, and 22 of treatment. On Day 22, subjects also left a sample of CSF for measurement of acamprosate. The results showed that steady-state level of acamprosate was accomplished within 5 days after the start of treatment and remained fairly stable for 2 to 3 days after termination of treatment. Variations in plasma concentrations corresponded to earlier studies and did not exceed those for comparable pharmacotherapeutic agents. Acamprosate concentrations in the CSF were below the limit of quantification, ie, estimated concentrations between 9 and 33 ng/mL. Plasma concentrations were more than 25 times higher than in lumbar CSF. The low CSF levels seen after 3 weeks of treatment may provide an explanation to the delay in therapeutic effect noticed in treatment studies on acamprosate. A longer duration of treatment might be necessary to obtain clinically significant brain levels of acamprosate. In summary, the present study validated liquid chromatography-mass spectrometry as a method for assessment of compliance to acamprosate treatment. Furthermore, the results suggest that the mechanism of action of acamprosate needs to be further explored with regard to

  1. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Feng

    2013-01-01

    Full Text Available Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  2. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution.

    Science.gov (United States)

    Feng, Xiao-Liang; He, Yun-Biao; Liang, Yi-Zeng; Wang, Yu-Lin; Huang, Lan-Fang; Xie, Jian-Wei

    2013-01-01

    Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  3. Determination of chlorophenols in landfill leachate using headspace sampling with ionic liquid-coated solid-phase microextraction fibers combined with gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Tse-Tsung; Chen, Chung-Yu [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China); Li Zuguang [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China); College of Chemical Engineering and Materials Science, Zhejiang University of Technology, Hangzhou 310014, Zhejiang (China); Yang, Thomas Ching-Cherng [Department of Chemistry, National Kaohsiung Normal University, Kaohsiung 82444, Taiwan (China); Lee, Maw-Rong, E-mail: mrlee@dragon.nchu.edu.tw [Department of Chemistry, National Chung Hsing University, Taichung 40227, Taiwan (China)

    2012-01-27

    Highlights: Black-Right-Pointing-Pointer Ionic liquid (IL), ([C{sub 4}MIM][PF{sub 6}]), was rapid synthesized by microwave radiation. Black-Right-Pointing-Pointer Trace chlorophenols in landfill leachate were extract by SPME coated IL. Black-Right-Pointing-Pointer The IL-coated SPME-GC/MS method is low-cost, solvent-free and sensitive. - Abstract: A new microextraction technique based on ionic liquid solid-phase microextraction (IL-SPME) was developed for determination of trace chlorophenols (CPs) in landfill leachate. The synthesized ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C{sub 4}MIM][PF{sub 6}]), was coated onto the spent fiber of SPME for extraction of trace CPs. After extraction, the absorbed analytes were desorbed and quantified using gas chromatography-mass spectrometry (GC/MS). The term of the proposed method is as ionic liquid-coated of solid-phase microextraction combined with gas chromatography-mass spectrometry (IL-SPME-GC/MS). No carryover effect was found, and every laboratory-made ionic liquids-coated-fiber could be used for extraction at least eighty times without degradation of efficiency. The chlorophenols studied were 2,4-dichlorophenol (2,4-DP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and pentachlorophenol (PCP). The best results of chlorophenols analysis were obtained with landfill leachate at pH 2, headspace extraction for 4 min, and thermal desorption with the gas chromatograph injector at 240 Degree-Sign C for 4 min. Linearity was observed from 0.1 to 1000 {mu}g L{sup -1} with relative standard deviations (RSD) less than 7% and recoveries were over 87%. The limit of detection (LOD) for pentachlorophenol was 0.008 {mu}g L{sup -1}. The proposed method was tested by analyzing landfill leachate from a sewage farm. The concentrations of chlorophenols were detected to range from 1.1 to 1.4 {mu}g L{sup -1}. The results demonstrate that the IL-SPME-GC/MS method is highly effective in

  4. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  5. Simultaneous analysis of fourteen tertiary amine stimulants in human urine for doping control purposes by liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Lu Jianghai; Wang San; Dong Ying; Wang Xiaobing; Yang Shuming; Zhang Jianli; Deng Jing; Qin Yang; Xu Youxuan; Wu Moutian; Ouyang Gangfeng

    2010-01-01

    A method for the simultaneous screening and confirmation of the presence of fourteen tertiary amine stimulants in human urine by gas chromatography-mass spectrometry (GC-MS) in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. Solid phase extraction (SPE) and liquid-liquid extraction (LLE) approaches were utilized for the pre-treatment of the urine samples. The study indicated that the capillary temperature played a significant role in the signal abundances of the protonated molecules of cropropamide and crotethamide under positive ion electrospray ionization (ESI) conditions. In addition, comparison studies of two different pre-treatment approaches as well as the two ionization modes were conducted. The LODs of the developed method for all the analytes were lower than the minimum required performance limit (MRPL) as set forth in the World Anti-Doping Agency (WADA) technical document for laboratories. The human urine sample obtained after oral administration of prolintane.HCl was successfully analyzed by the developed method, which demonstrated the applicability and reliability of the method for routine doping control analysis.

  6. Analysis of Nitro-aromatic and Nitramine Explosives by Atmospheric Pressure Chemical Ionization / High Performance Liquid Chromatography / Mass Spectrometry / Mass Spectrometry

    International Nuclear Information System (INIS)

    Hicks, B.J.; Han, W.; Robben, J.R.

    2009-01-01

    This procedure is capable of separating and quantifying twenty-nine high explosives and internal surrogates with a single injection. After the initial preparation step, the sample is introduced to the high performance liquid chromatograph for target separation, ionized by atmospheric pressure chemical ionization and the explosives of interest are isolated / quantified by mass spectrometry / mass spectrometry. Concentrations of the target explosives are measured relative to the response of both internal and external standard concentrations. A C-18 reverse phase high performance liquid chromatograph column is used for separation. Ionization is performed using both positive and negative atmospheric pressure chemical ionization resulting in a molecular ion with little fragmentation. These ions are isolated at the first quadrupole of the mass spectrometer, dissociated by collision with argon in the collision cell and the resulting daughter ions are isolated at the second quadrupole. These daughter ions then reach the detector where they are quantified. To date this procedure represents the most thorough high performance liquid chromatography / mass spectrometry / mass spectrometry explosives analysis available in the environmental chemistry market. (authors)

  7. Dehydroepiandrosterone sulfate quantification in serum using high-performance liquid chromatography/mass spectrometry and a deuterated internal standard: a technique suitable for routine use or as a reference method

    International Nuclear Information System (INIS)

    Shackleton, C.H.; Kletke, C.; Wudy, S.; Pratt, J.H.

    1990-01-01

    A thermospray high-performance liquid chromatography/mass spectrometry method for determination of serum dehydroepiandrosterone sulfate is described. The steroid was measured intact using [7,7-2H2]dehydroepiandrosterone sulfate as internal standard. The analysis was carried out in the negative ion mode by determining the peak height ratio of the molecular anions of the analyte and internal standard. The method was used to determine the steroid in serum from 15 male and female normal adults and the following values were obtained: males, 272 +/- 45 micrograms/dl (range, 197 to 331 micrograms/dl) and females, 215 +/- 67 micrograms/dl (range, 107 to 347 micrograms/dl). In addition, dehydroepiandrosterone sulfate was measured by high-performance liquid chromatography/mass spectrometry and radioimmunoassay (a commercial kit) on 25 individuals of all age groups. There was strong correlation between the values obtained, but the radioimmunoassay values were generally double those obtained by high-performance liquid chromatography/mass spectrometry. Three other steroid sulfates, androsterone sulfate, epiandrosterone sulfate, and androst-5-ene-3 beta, 17 beta-diol sulfate, were also assayed. In males, these had mean values of 112, 44, and 13 micrograms/dl and, in females, they had mean values of 84, 25, and 6 micrograms/dl, respectively. Radioimmunoassay cross-reactivity measurement for these steroids (as reference compounds) showed that they were unlikely to contribute greatly to the discrepancy between radioimmunoassay and high-performance liquid chromatography/mass spectrometry values

  8. Simultaneous determination of amoxicillin and clavulanic acid in the human plasma by high performance liquid chromatography: Mass spectrometry (UPLC/MS

    Directory of Open Access Journals (Sweden)

    Ćirić Biljana

    2010-01-01

    Full Text Available Background/Aim. Quantitative analysis of amoxicillin and clavulanic acid in biological matrices requires sensitive and specific methods which allow determination of therapeutic concentration in μg/mL range. Analytical methods for determination of their concentrations in body fluids described in literature include high performance liquid chromatography coupled to UV detector (HPLC-UV and liquid chromatography-mass spectrometry (LC-MS. The aim of this study was to develop sensitive and specific ultra performance liquid chromatography/ mass spectrometry (UPLC/MS method which could be used for the spectral identification and quantification of the low concentrations of amoxicillin and clavulanic acid in the human plasma. Method. A sensitive and specific UPLC/MS method for amoxicillin and clavulanic acid determination was developed in this study. The samples were taken from the adult healthy volunteers receiving per os one tablet of amoxicillin (875 mg in combination with clavulanic acid (125 mg. Results. Plasma samples were pretreated by direct deproteinization with perchloric acid. Quantification limit of 0.01 μg/ml for both amoxicillin and clavulanic acid was achieved. The method was reproducible day by day (RSD < 7 %. Analytical recoveries for amoxicillin ranged from 98.82% to 100.9% (for concentrations of 1, 5 and 20 μg/mL, and recoveries for clavulanic acid were 99,89% to 100.1% (for concentrations of 1, 2 and 5 μg/mL. This assay was successfully applied to a pilot pharmacokinetic study in healthy volunteers after a single-oral administration of amoxicillin/ clavulanic combination. The determined plasma concentrations of both amoxicillin and clavulanic acid were in the range of the expected values upon the literature data for HPLC-UV and LC-MS methods. Conclusion. The described method provided a few advantages comparing with LC/MS-MS method. The method is faster using running time of 5 minute, has lower limit of quantification (LOQ and it

  9. Ionic liquid based vortex assisted liquid-liquid microextraction combined with liquid chromatography mass spectrometry for the determination of bisphenols in thermal papers with the aid of response surface methodology.

    Science.gov (United States)

    Asati, Ankita; Satyanarayana, G N V; Panchal, Smita; Thakur, Ravindra Singh; Ansari, Nasreen G; Patel, Devendra K

    2017-08-04

    A sensitive, rapid and efficient ionic liquid-based vortex assisted liquid-liquid microextraction (IL-VALLME) with Liquid Chromatography Mass spectrometry (LC-MS/MS) method is proposed for the determination of bisphenols in thermal paper. Extraction factors were systematically optimized by response surface methodology. Experimental factors showing significant effects on the analytical responses were evaluated using design of experiment. The limit of detection for Bisphenol-A (BPA) and Bisphenol-S (BPS) in thermal paper were 1.25 and 0.93μgkg -1 respectively. The dynamic linearity range for BPA was between 4 and 100μgkg -1 and the determination of coefficient (R 2 ) was 0.996. The values of the same parameters were 3-100μgkg -1 and 0.998 for BPS. The extraction recoveries of BPA and BPS in thermal paper were 101% and 99%. Percent relative standard deviation (% RSD) for matrix effect and matrix match effects were not more than 10%, for both bisphenols. The proposed method uses a statistical approach for the analysis of bisphenols in environmental samples, and is easy, rapid, requires minimum organic solvents and efficient. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A Metabolomics-Guided Exploration of the Phytochemical Constituents of Vernonia fastigiata with the Aid of Pressurized Hot Water Extraction and Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Masike, Keabetswe; Khoza, Bradley S; Steenkamp, Paul A; Smit, Elize; Dubery, Ian A; Madala, Ntakadzeni E

    2017-07-27

    Vernonia fastigiata is a multi-purpose nutraceutical plant with interesting biological properties. However, very little is known about its phytochemical composition and, thus the need for its phytochemical characterization. In the current study, an environmentally friendly method, pressurized hot water extraction (PHWE), was used to extract metabolites from the leaves of V. fastigiata at various temperatures (50 °C, 100 °C, 150 °C and 200 °C). Ultra-high performance liquid chromatography-quadrupole time of flight mass spectrometry (UHPLC-qTOF-MS) analysis in combination with chemometric methods, particularly principal component analysis (PCA) and liquid/gas chromatography mass spectrometry (XCMS) cloud plots, were used to descriptively visualize the data and identify significant metabolites extracted at various temperatures. A total of 25 different metabolites, including hydroxycinnamic acid derivatives, clovamide, deoxy-clovamide and flavonoids, were noted for the first time in this plant. Overall, an increase in extraction temperature resulted in an increase in metabolite extraction during PHWE. This study is the first scientific report on the phytochemical composition of V. fastigiata , providing insight into the components of the chemo-diversity of this important plant.

  11. Technical report Development of a piezoelectric inkjet dopant delivery device for an atmospheric pressure photoionization source with liquid chromatography/mass spectrometry

    KAUST Repository

    Amad, Maan H.

    2013-01-01

    This paper describes a simple robust and integrated piezoelectric actuated printhead as a dopant delivery system for atmospheric pressure photoionization with liquid chromatography/mass spectrometry The newly designed dopant delivery system avoids problems associated with traditional liquid delivery systems such as solvent immiscibility backpressure and increased post-column dead volume issues The performance of the new device was tested and evaluated using chlorobenzene as a dopant with a test mixture consisting of 18 different polycyclic aromatic hydrocarbons (PAHs) The results show that the new system works robustly at low dopant consumption level (16 uL min-1) consuming only approximately 5% of the amount used by conventional sources The low dopant consumption has resulted in up to a 20-fold reduction in signal intensity of tested PAH molecules but has led to less presence of background cluster ions and dopant trace contaminant background ions in the source area Consequently all tested PAHs were detected with excellent signal-to-noise ratio with at least two-to ten-fold improvements in the limit of detection and quantification compared to those obtained with traditional dopant assistance using a post-column addition method © IM Publications LLP 2013.

  12. Analysis of Glyphosate and Aminomethylphosphonic Acid in Nutritional Ingredients and Milk by Derivatization with Fluorenylmethyloxycarbonyl Chloride and Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ehling, Stefan; Reddy, Todime M

    2015-12-09

    A straightforward analytical method based on derivatization with fluorenylmethyloxycarbonyl chloride and liquid chromatography-mass spectrometry has been developed for the analysis of residues of glyphosate and aminomethylphosphonic acid (AMPA) in a suite of nutritional ingredients derived from soybean, corn, and sugar beet and also in cow's milk and human breast milk. Accuracy and intermediate precision were 91-116% and soy protein isolate. Limits of quantitation were 0.05 and 0.005 μg/g in powdered and liquid samples, respectively. Glyphosate and AMPA were quantified at 0.105 and 0.210 μg/g (soy protein isolate) and 0.850 and 2.71 μg/g (soy protein concentrate, both derived from genetically modified soybean), respectively. Residues were not detected in soy milk, soybean oil, corn oil, maltodextrin, sucrose, cow's milk, whole milk powder, or human breast milk. The method is proposed as a convenient tool for the survey of glyphosate and AMPA in the ingredient supply chain.

  13. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng; Shen Jianzhong

    2009-01-01

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg -1 , respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  14. Application of liquid chromatography-mass spectrometry in research of plant proteins and peptides%液相色谱质谱联用技术在植物蛋白及多肽研究中的应用

    Institute of Scientific and Technical Information of China (English)

    许岩; 任皓威; 周广运; 刘宁

    2017-01-01

    With liquid chromatography-mass spectrometry technology developing continuously,the liquid chromatography-mass spectrometry technology has been widely available in the field of medicine,environment,food security recently,and also play a key role in plant protein and peptide research.Recently advances on development of liquid chromatography-mass spectrometry and liquid chromatography-mass spectrometry application in the cereals,legumes and other crop proteins were reviewed.The development trend and prospects of plant protein research by liquid chromatography-mass spectrometry were used to provide the latest basic theory for the further study of plant proteins.%近年来,随着液相色谱质谱联用技术的发展,其在医药、环境和食品安全等领域中已得到广泛应用,目前也成为植物蛋白研究的重要手段.本文将从液相色谱质谱联用技术发展及液相色谱质谱联用技术在谷物蛋白、豆类蛋白及其他作物蛋白中的研究和应用进行归纳和总结,并对液相色谱质谱联用技术在植物蛋白研究中的发展方向和前景进行展望,以期为植物蛋白的深入研究提供最新的基础理论.

  15. A liquid chromatography-mass spectrometric method for the determination of oak moss allergens atranol and chloroatranol in perfumes

    DEFF Research Database (Denmark)

    Bossi, Rossana; Rastogi, Suresh Chandra; Bernard, Guillaume

    2004-01-01

    This paper describes a validated liquid chromatographic-tandem mass spectrometric method for quantitative analysis of the potential oak moss allergens atranol and chloroatranol in perfumes and similar products. The method employs LC-MS-MS with electrospray ionization (ESI) in negative mode...

  16. Identification and quantification of cannabinoids in Cannabis sativa L. plants by high performance liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Aizpurua-Olaizola, Oier; Omar, Jone; Navarro, Patricia; Olivares, Maitane; Etxebarria, Nestor; Usobiaga, Aresatz

    2014-01-01

    High performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) has been successfully applied to cannabis plant extracts in order to identify cannabinoid compounds after their quantitative isolation by means of supercritical fluid extraction (SFE). MS conditions were optimized by means

  17. Determination of periplocymarin in human blood and urine by high-performance liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chen Jian Xia

    2017-01-01

    Full Text Available A simple, rapid and sensitive liquid chromatography with tandem mass spectrometry method for the determination of periplocymarin in human blood and urine was developed. The digoxin-d3 was used as an internal standard. Periplocymarin and digoxin-d3 (IS were processed with ethyl acetate by liquid-liquid extraction. The chromatographic separation was performed on a Shim-pack XR-ODSIII C18 column with a 7 min gradient elution using methanol-ammonium formate (5 mmol/L as mobile phase at a flow rate of 0.3 mL/min (65:35, v/v. The detection was performed on a triple quadrupole tandem mass spectrometer using positive-ion mode electrospray ionization in selected reaction monitoring mode. The periplocymarin was well separated from the internal standard. Two calibration curves were linear within the concentration range 0.01-1 μg/mL. The limit of detection and quantification of blood and urine samples were both estimated at 0.005 and 0.01 μg/mL. The interday and intraday precisions, accuracy, and recovery were assessed to verify this method. The results showed that the method was suitable for the determination of periplocymarin in forensic toxicological analysis and clinical diagnosis.

  18. Novel determination of polychlorinated naphthalenes in water by liquid chromatography-mass spectrometry with atmospheric pressure photoionization.

    Science.gov (United States)

    Moukas, Athanasios I; Thomaidis, Nikolaos S; Calokerinos, Antony C

    2016-01-01

    This study presents the development, optimization, and validation of a novel method for the determination of polychlorinated naphthalenes (PCNs) by liquid chromatography-atmospheric pressure photoionization (APPI), using toluene as dopant. The mass spectra of PCN 52, 54, 66, 67, 73, and 75 were recorded in negative ionization. The base ions corresponded to [M-Cl+O](-), where M is the analyte molecule. A strategy, which includes designs of experiments, for the development, the evaluation, and the optimization of the LC-APPI-MS/MS methods is also described. Finally, a highly sensitive method with low instrumental limits of detection (LoDs), ranging from 0.8 pg for PCN 75 to 16 pg for PCN 54 on column, was validated. A Thermo Hypersil Green PAH (100 mm × 2.1 mm, 3 μm) column was used with acetonitrile/water/methanol as mobile phase. The method was applied for the determination of the selected PCNs in surface and tap water samples. A simple liquid-liquid extraction method for the extraction of PCNs from water samples was used. Method LoQs ranged from 29 ng L(-1), for PCN 73, to 63 ng L(-1), for PCN 54, and the recoveries ranged from 97 to 99%, for all congeners. This is the first LC-APPI-MS/MS method for the determination of PCNs in water samples.

  19. Determination of methylphenidate in Calliphorid larvae by liquid-liquid extraction and liquid chromatography mass spectrometry - Forensic entomotoxicology using an in vivo rat brain model

    DEFF Research Database (Denmark)

    Bushby, Sarah K.; Thomas, Nicky; Priemel, Petra A.

    2012-01-01

    and Calliphorid larvae) by liquid-liquid extraction with recovery of >80%, and quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS assay was validated for entomotoxicological use and initially applied to male Sprague-Dawley rats (n=6) that were dosed with MPH (20mg/kg) ante...

  20. Hydrophilic Interaction Liquid Chromatography/Mass Spectrometry: An Attractive and Prospective Method for the Quantitative Bioanalysis in Drug Metabolism.

    Science.gov (United States)

    Li, Zheng; Han, Jie; Sun, Shi-an; Chen, Kai; Tang, Dao-quan

    2016-01-01

    During the development, dosage optimization and safety evaluation of a drug, rapid and precise monitoring of administered drug and/or its metabolites in biological samples including blood, plasma, serum, tissues and saliva are vital. As drug biotransformation produces more hydrophilic metabolites for the enhancement of drug elimination, which is often a challenge for traditional reversed-phase liquid chromatography (RPLC) separation. Because hydrophilic interaction liquid chromatography (HILIC) is capable of retaining polar compounds and readily compatible with mass spectrometry (MS), HILIC has been used as a complementary separation technique to RPLC for analysis of polar metabolites, especially polar drugs and their metabolites. This review covers core aspects of HILIC-MS/MS method and overall profile of its application in analysis of drug and/or its metabolites. The emphasis of this paper has been placed on the applications of HILIC-MS/MS method in quantitative bioanalysis of drugs alone or along with their metabolites in drug metabolism studies in recent years. As a fundamental and critical step of bioanalytical method, conventional sample preparation techniques of biological matrices for the HILIC-MS/MS analysis of drugs and/or their metabolites are also briefly featured.

  1. Determination of flumazenil in serum by liquid chromatography-mass spectrometry: Application to kinetics study in acute diazepam overdose.

    Science.gov (United States)

    Djordjević, Snezana; Jović-Stosić, Jasmina; Kilibarda, Vesna; Segrt, Zoran; Perković-Vukcević, Natasa

    2016-02-01

    Flumazenil is benzodiazepine receptor antagonist. It has been studied for a various indications, including reversal of sedation after surgery or diagnostic procedures, awakening of comatose patients in benzodiazepine overdose, or for symptomatic treatment of hepatic encephalopathy. Some drugs, like theophylline, may prolong its elimination half-life. Considering the long half-life of diazepam and its metabolites, concomitant use of theophylline may reduce the need for repeated dosing of flumazenil in patients with acute diazepam poisoning. The aim of this study was to introduce a reliable and accurate method for determining the concentration of flumazenil after therapeutic application in patients with acute poisoning, and using that method to assess whether the kinetics of flumazenil change in the presence of aminophylline (combination of theophylline and ethylenediamine in a 2:1 ratio) applied as concomitant therapy. Blood samples from patients with acute diazepam poisoning that received flumazenil at the dose of 0.5 mg, or the same dose with 3 mg/kg of body weight of aminophylline, were collected 1, 3, 10, 30, 60, 120 and 240 min after its intravenous administration. Samples were prepared by solid-phase extraction on Oasis HLB cartridges with ethylacetate as extracting agens. Flumazenil was determined by liquid chromatography with mass spectrometry (LC-MS) in single ionmonitoring mode at m/z 304. Separation of flumazenil from matrix compound was performed on Lichrospher RP-8 column usingthe mixture of acidic acetonitrile and 20 mM of ammonium acetatein water (55 : 45) as a mobile phase. The applied analitycal method showed excellent recovery (94.65%). The obtained extracts were much cleaner than the extracts obtained by the sameextractant in the process of liquid-liquid extraction. The limit ofdetection of the LC-MS method described in this paper was 0.5 ng/mL and the limit of quantitation was 1 ng/mL. In the patientstreated with both flumazenil and aminophylline

  2. Determination of flumazenil in serum by liquid chromatography-mass spectrometry: Application to kinetics study in acute diazepam overdose

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2016-01-01

    Full Text Available Backgound/Aim. Flumazenil is benzodiazepine receptor antagonist. It has been studied for a various indications, including reversal of sedation after surgery or diagnostic procedures, awakening of comatose patients in benzodiazepine overdose, or for symptomatic treatment of hepatic encephalopathy. Some drugs, like theophylline, may prolong its elimination half-life. Considering the long half-life of diazepam and its metabolites, concomitant use of theophylline may reduce the need for repeated dosing of flumazenil in patients with acute diazepam poisoning. The aim of this study was to introduce a reliable and accurate method for determining the concentration of flumazenil after therapeutic application in patients with acute poisoning, and using that method to assess whether the kinetics of flumazenil change in the presence of aminophylline (combination of theophylline and ethylenediamine in a 2 : 1 ratio applied as concomitant therapy. Methods. Blood samples from patients with acute diazepam poisoning that received flumazenil at the dose of 0.5 mg, or the same dose with 3 mg/kg of body weight of aminophylline, were collected 1, 3, 10, 30, 60, 120 and 240 min after its intravenous administration. Samples were prepared by solid-phase extraction on Oasis HLB cartridges with ethylacetate as extracting agens. Flumazenil was determined by liquid chromatography with mass spectrometry (LC-MS in single ion monitoring mode at m/z 304. Separation of flumazenil from matrix compound was performed on Lichrospher RP-8 column using the mixture of acidic acetonitrile and 20 mM of ammonium acetate in water (55 : 45 as a mobile phase. Results. The applied analitycal method showed excellent recovery (94.65%. The obtained extracts were much cleaner than the extracts obtained by the same extractant in the process of liquid-liquid extraction. The limit of detection of the LC-MS method described in this paper was 0.5 ng/mL and the limit of quantitation was 1 ng/mL. In

  3. Determination of membrane degradation products in the product water of polymer electrolyte membrane fuel cells using liquid chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zedda, Marco

    2011-05-12

    The predominant long term failure of polymer electrolyte membranes (PEM) is caused by hydroxyl radicals generated during fuel cell operation. These radicals attack the polymer, leading to chain scission, unzipping and consequently to membrane decomposition products. The present work has investigated decomposition products of novel sulfonated aromatic hydrocarbon membranes on the basis of a product water analysis. Degradation products from the investigated membrane type and the possibility to detect these compounds in the product water for diagnostic purposes have not been discovered yet. This thesis demonstrates the potential of solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) for the extraction, separation, characterization, identification and quantification of membrane degradation products in the product water of fuel cells. For this purpose, several polar aromatic hydrocarbons with different functional groups were selected as model compounds for the development of reliable extraction, separation and detection methods. The results of this thesis have shown that mixed mode sorbent materials with both weak anion exchange and reversed phase retention properties are well suited for reproducible extraction of both molecules and ions from the product water. The chromatographic separation of various polar aromatic hydrocarbons was achieved by means of phase optimized liquid chromatography using a solvent gradient and on a C18 stationary phase. Sensitive and selective detection of model compounds could be successfully demonstrated by the analysis of the product water using tandem mass spectrometry. The application of a hybrid mass spectrometer (Q Trap) for the characterization of unknown polar aromatic hydrocarbons has led to the identification and confirmation of 4-hydroxybenzoic acid in the product water. In addition, 4-HBA could be verified as a degradation product resulting from PEM decomposition by hydroxyl radicals using an

  4. Monitoring changes in anthocyanin and steroid alkaloid glycoside content in lines of transgenic potato plants using liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Stobiecki, Maciej; Matysiak-Kata, Iwona; Frański, Rafał; Skała, Jacek; Szopa, Jan

    2003-03-01

    Transgenic potato plants overexpressing and repressing enzymes of flavonoids biosynthesis were created and analyzed. The selected plants clearly showed the expected changes in anthocyanins synthesis level. Overexpression of a DNA encoding dihydroflavonol 4-reductase (DFR) in sense orientation resulted in an increase in tuber anthocyanins, a 4-fold increase in petunidin and pelargonidin derivatives. A significant decrease in anthocyanin level was observed when the plant was transformed with a corresponding antisense construct. The transformation of potato plants was also accompanied by significant changes in steroid alkaloid glycosides (SAG) level in transgenic potato tuber. The changes in SAGs content was not dependent on flavonoid composition in transgenic potato. However, in an extreme situation where the highest (DFR11) or the lowest (DFRa3) anthocyanin level was detected the positive correlation with steroid alkaloid content was clearly visible. It is suggested that the changes in SAGs content resulted from chromatin stressed upon transformation. A liquid chromatography/mass spectrometry (LC/MS) system with electrospray ionization was applied for profiling qualitative and quantitative changes of steroid alkaloid glycosides in tubers of twelve lines of transgenic potato plants. Except alpha-chaconine and alpha-solanine, in the extracts from dried tuber skin alpha-solamargine and alpha-solasonine, triglycosides of solasonine, were identified in minor amounts, triglycosides of solanidine dehydrodimers were also recognized.

  5. An evaluation of liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization for the rapid and simultaneous measurement of carbamate pesticides and organophorus pesticides

    International Nuclear Information System (INIS)

    Kim, Byung Joo; So, Hun Young

    2000-01-01

    Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 μg/mL. The peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to tun. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng

  6. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays.

    Science.gov (United States)

    Rezende, Vinicius Marcondes; Rivellis, Ariane; Novaes, Mafalda Megumi Yoshinaga; de Alencar Fisher Chamone, Dalton; Bendit, Israel

    2013-01-01

    Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring. A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500-10.0 μg/mL with a limit of detection of 0.155 μg/mL. Stability data for the analyte are also presented. Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.

  7. Phytochemical analyses of Ziziphus jujuba Mill. var. spinosa seed by ultrahigh performance liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Bao; Yang, Hongshun; Chen, Feng; Hua, Yanglin; Jiang, Yueming

    2013-11-21

    Ziziphus jujuba Mill. var. spinosa (Z. jujuba) seeds have attracted much attention within the field of medicine due to their significant effects against disturbances of the central nervous system. Secondary metabolites composition is key to the influence of the pharmaceutical and commercial qualities of this plant. In this work, the phytochemical profile of Z. jujuba seeds was analysed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and gas chromatography-mass spectrometry (GC-MS). The UPLC-MS/MS information identified the main secondary metabolites in Z. jujuba seeds, including flavonoid C-glycosides, triterpene acids and unsaturated fatty acids. The leading chemical identified by UPLC-MS/MS was betulinic acid, and oleic acid was the leading volatile from the GC-MS results. All the samples tested showed similar phytochemical profiles, but levels of the chemical compounds varied. Principal component analysis revealed the principal secondary metabolites that could define the differences in quality. It was confirmed that the combination of UPLC-MS/MS and GC-MS was an effective technique to demonstrate the pharmaceutical quality of Z. jujuba seeds.

  8. Rapid, Sensitive and Validated Ultra-Performance Liquid Chromatography/Mass Spectrometric Method for the Determination of Fenofibric Acid and its Application to Human Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Sunil K. Dubey

    2010-01-01

    Full Text Available The first, rapid and sensitive ultra performance liquid chromatography mass spectrometric method for the determination of fenofibric acid, the active metabolite of fenofibrate, a lipid regulating agent, in human EDTA plasma has been developed and validated using fenofibric d6 acid as internal standard and Waters LC-MS/MS. Negative ions of fenofibric acid and fenofibric d6 acid were detected in multiple reaction-monitoring (MRM mode. The method was validated over a concentration range of 0.176 μg/mL to 19.837 μg/mL (r ≥ 0.99. It took only 1.5 minute to analyse a sample. Intra- and inter-run precision of fenofibric acid assay at four concentrations ranged from 0.5% to 4.3% with accuracy varied from 93.1 to 108.1% indicating good precision and accuracy. Analytical recoveries of fenofibric acid and internal standard in plasma were less than 90%. This method was successfully applied for evaluation of pharmacokinetics of fenofibric acid after a single oral dose of 145 mg fenofibrate to 10 Indian healthy volunteers

  9. A rapid approach for characterization of thiol-conjugated antibody-drug conjugates and calculation of drug-antibody ratio by liquid chromatography mass spectrometry.

    Science.gov (United States)

    Firth, David; Bell, Leonard; Squires, Martin; Estdale, Sian; McKee, Colin

    2015-09-15

    We present the demonstration of a rapid "middle-up" liquid chromatography mass spectrometry (LC-MS)-based workflow for use in the characterization of thiol-conjugated maleimidocaproyl-monomethyl auristatin F (mcMMAF) and valine-citrulline-monomethyl auristatin E (vcMMAE) antibody-drug conjugates. Deconvoluted spectra were generated following a combination of deglycosylation, IdeS (immunoglobulin-degrading enzyme from Streptococcus pyogenes) digestion, and reduction steps that provide a visual representation of the product for rapid lot-to-lot comparison-a means to quickly assess the integrity of the antibody structure and the applied conjugation chemistry by mass. The relative abundance of the detected ions also offer information regarding differences in drug conjugation levels between samples, and the average drug-antibody ratio can be calculated. The approach requires little material (<100 μg) and, thus, is amenable to small-scale process development testing or as an early component of a complete characterization project facilitating informed decision making regarding which aspects of a molecule might need to be examined in more detail by orthogonal methodologies. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. A rapid and sensitive evaluation of nitrite content in Saudi Arabian processed meat and poultry using a novel ultra performance liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    Siddiqui, Masoom Raza; Wabaidur, Saikh Mohammad; Khan, Moonis Ali; ALOthman, Zeid A; Rafiquee, M Z A; Alqadami, Ayoub Abdullah

    2018-01-01

    Quantitative assessment of nitrite (NO 2 - ) anion was performed using a newly developed high throughput ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method. The nitrite determination with the proposed method using micellar mobile phase was unknown. Selected ion reaction mode using negative electrospray ionization was adopted for the identification and quantitative analysis of nitrite. The chromatographic separation was performed using BEH C-18 column and a micellar mobile phase consisted of sodium dodecyl sulphate and acetonitrile in ratio 30:70 was used. The elution of nitrite anion was accomplished in less than 1 min. Under the optimal analysis conditions, the linearity of the developed method was checked in the concentration range of 0.5-20 mg kg -1 NO 2 - with an excellent correlation coefficient of 0.996. The precisions of the method with relative standard deviation <2% was observed when standard at concentration of 1 mg kg -1 was used. The limit of detection and limit of quantitation of the developed mass spectrometric method was found to be 0.114 and 0.346 mg kg -1 , respectively. The developed UPLC/MS method was applied to quantify this anion in processed meats and poultries from various super market of Saudi Arabia (Riyadh region). The recoveries of the nitrite in the various samples were found in the range of 100.03-103.5%.

  11. Periodic modulation-based stochastic resonance algorithm applied to quantitative analysis for weak liquid chromatography-mass spectrometry signal of granisetron in plasma

    Science.gov (United States)

    Xiang, Suyun; Wang, Wei; Xiang, Bingren; Deng, Haishan; Xie, Shaofei

    2007-05-01

    The periodic modulation-based stochastic resonance algorithm (PSRA) was used to amplify and detect the weak liquid chromatography-mass spectrometry (LC-MS) signal of granisetron in plasma. In the algorithm, the stochastic resonance (SR) was achieved by introducing an external periodic force to the nonlinear system. The optimization of parameters was carried out in two steps to give attention to both the signal-to-noise ratio (S/N) and the peak shape of output signal. By applying PSRA with the optimized parameters, the signal-to-noise ratio of LC-MS peak was enhanced significantly and distorted peak shape that often appeared in the traditional stochastic resonance algorithm was corrected by the added periodic force. Using the signals enhanced by PSRA, this method extended the limit of detection (LOD) and limit of quantification (LOQ) of granisetron in plasma from 0.05 and 0.2 ng/mL, respectively, to 0.01 and 0.02 ng/mL, and exhibited good linearity, accuracy and precision, which ensure accurate determination of the target analyte.

  12. Simultaneous determination of sulfonamides, tetracyclines and tiamulin in swine wastewater by solid-phase extraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Ben, Weiwei; Qiang, Zhimin; Adams, Craig; Zhang, Heqing; Chen, Liping

    2008-08-22

    Little is known about the contamination level of antibiotics in swine wastewater in China. The highly complex matrix of swine wastewater, which generally has a chemical oxygen demand (COD) concentration as high as 15,000 mg/L, makes it difficult to detect antibiotics at trace levels. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of three classes of commonly used veterinary antibiotics including five sulfonamides, three tetracyclines and one macrolide in swine wastewater using solid-phase extraction (SPE) and liquid chromatography-mass spectrometry (LC-MS). The method detection limits (MDL) in the swine wastewater were determined to be between 5 and 91 ng/L, depending on specific antibiotics. Except sulfamethizole, all the other eight antibiotics were detected in the swine wastewaters collected from three concentrated swine feeding plants located in the Beijing (China) area, showing a concentration range of 0.62-32.67 microg/L. These results reveal the representative concentration levels of selected antibiotics in the swine wastewaters of Beijing area.

  13. Simultaneous monitoring of oxidation, deamidation, isomerization, and glycosylation of monoclonal antibodies by liquid chromatography-mass spectrometry method with ultrafast tryptic digestion.

    Science.gov (United States)

    Wang, Yi; Li, Xiaojuan; Liu, Yan-Hui; Richardson, Daisy; Li, Huijuan; Shameem, Mohammed; Yang, Xiaoyu

    Monoclonal antibodies are subjected to a wide variety of post-translational modifications (PTMs) that cause structural heterogeneity. Characterization and control of these modifications or quality attributes are critical to ensure antibody quality and to define any potential effects on the ultimate safety and potency of antibody therapeutics. The biopharmaceutical industry currently uses numerous tools to analyze these quality attributes individually, which requires substantial time and resources. Here, we report a simple and ultrafast bottom-up liquid chromatography-mass spectrometry (uLC-MS) method with 5 min tryptic digestion to simultaneously analyze multiple modifications, including oxidation, deamidation, isomerization, glycation, glycosylation, and N-terminal pyro-glutamate formation, which can occur during antibody production in mammalian cell culture, during purification and/or on storage. Compared to commonly used preparation procedures, this uLC-MS method eliminates assay artifacts of falsely-increased Met oxidation, Asp isomerization, and Asn deamidation, a problem associated with long digestion times in conventional LC-MS methods. This simple, low artifact multi-attribute uLC-MS method can be used to quickly and accurately analyze samples at any stage of antibody drug development, in particular for clone and media selection during cell culture development.

  14. Analysis of trace levels of sulfonamide and tetracycline antimicrobials in groundwater and surface water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lindsey, M.E.; Meyer, M.; Thurman, E.M.

    2001-01-01

    A method has been developed for the trace analysis of two classes of antimicrobials consisting of six sulfonamides (SAs) and five tetracyclines (TCs), which commonly are used for veterinary purposes and agricultural feed additives and are suspected to leach into ground and surface water. The method used solid-phase extraction and liquid chromatography/mass spectrometry (LC/MS) with positive ion electrospray. The unique combination of a metal chelation agent (Na2EDTA) with a macroporous copolymer resulted in quantitative recoveries by solid-phase extraction (mean recovery, 98 ?? 12%) at submicrogram-per-liter concentrations. An ammonium formate/formic acid buffer with a methanol/water gradient was used to separate the antimicrobials and to optimize the signal intensity. Mass spectral fragmentation and ionization characteristics were determined for each class of compounds for unequivocal identification. For all SAs, a characteristic m/z 156 ion representing the sulfanilyl fragment was identified. TCs exhibited neutral losses of 17 amu resulting from the loss of ammonia and 35 amu from the subsequent loss of water. Unusual matrix effects were seen only for TCs in this first survey of groundwater and surface water samples from sites around the United States, requiring that TCs be quantitated using the method of standard additions.

  15. Evaluation of the impact of sulfobutylether7 -β-cyclodextrin on the liquid chromatography-mass spectrometry analysis of biological samples arising from in vivo pharmacokinetic studies.

    Science.gov (United States)

    Leong, Nathania J; Prankerd, Richard J; Shackleford, David M; Mcintosh, Michelle P

    2015-04-01

    The utility of cyclodextrin (CD) complexation in improving apparent solubility of drugs in parenteral formulations is well established. Administration of these formulations delivers CD directly into the systemic circulation, and it may be necessary to demonstrate unaltered in vivo disposition of a drug coadministered with a CD. Crucial to the undertaking of such a study is the need for bioanalytical assays in which CD presence does not impact drug quantitation. This is of particular importance when assessing the potential impact of in vivo CD complexation on the urinary excretion of a drug, as CDs are predominantly eliminated via glomerular filtration, and hence are present in urine at significantly higher concentration than would be present in blood and plasma. Of 23 publications (in the past 30 years) describing preclinical and clinical assessment of drug pharmacokinetics after i.v. administration of CD-enabled formulations, only two reports clearly stated that the presence of CD had no impact on assay performance. In this work, we describe the simple process involved in (1) predicting the maximum concentrations of a modified CD, sulfobutylether7 -β-CD (SBE7 -β-CD), in plasma and urine samples from preclinical studies, and (2) evaluating the impact of SBE7 -β-CD on the quantitative liquid chromatography-mass spectrometry analysis of rimantadine. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  16. Rapid and interference-free analysis of nine B-group vitamins in energy drinks using trilinear component modeling of liquid chromatography-mass spectrometry data.

    Science.gov (United States)

    Hu, Yong; Wu, Hai-Long; Yin, Xiao-Li; Gu, Hui-Wen; Xiao, Rong; Xie, Li-Xia; Liu, Zhi; Fang, Huan; Wang, Li; Yu, Ru-Qin

    2018-04-01

    The aim of the present work was to develop a rapid and interference-free method based on liquid chromatography-mass spectrometry (LC-MS) for the simultaneous determination of nine B-group vitamins in various energy drinks. A smart and green strategy that modeled the three-way data array of LC-MS with second-order calibration methods based on alternating trilinear decomposition (ATLD) and alternating penalty trilinear decomposition (APTLD) algorithms was developed. By virtue of "mathematical separation" and "second-order advantage", the proposed strategy successfully solved the co-eluted peaks and unknown interferents in LC-MS analysis with the elution time less than 4.5min and simple sample preparation. Satisfactory quantitative results were obtained by the ATLD-LC-MS and APTLD-LC-MS methods for the spiked recovery assays, with the average spiked recoveries ranging from 87.2-113.9% to 92.0-111.7%, respectively. These results acquired from the proposed methods were confirmed by the LC-MS/MS method, which shows a quite good consistency with each other. All these results demonstrated that the developed chemometrics-assisted LC-MS strategy had advantages of being rapid, green, accurate and low-cost, and it could be an attractive alternative for the determination of multiple vitamins in complex food matrices, which required no laborious sample preparation, tedious condition optimization or more sophisticated instrumentations. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Dual-target screening of bioactive components from traditional Chinese medicines by hollow fiber-based ligand fishing combined with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Liang; Wang, Xin; Liu, Youping; Di, Xin

    2017-09-05

    A novel strategy was developed for dual-target screening of bioactive components from traditional Chinese medicines (TCMs). This strategy was based on the use of low-cost microporous hollow fibers filled with target enzymes as baits to "fish out" the ligands in TCM extracts, followed by identification of the ligands dissociated from the target-ligand complexes by liquid chromatography-mass spectrometry. Ganjiang Huangqin Huanglian Renshen Decoction (GHHRD), a classical TCM prescription for diabetes treatment, was chosen as a model sample to evaluate the feasibility of the proposed strategy. Three bioactive components were successfully screened out from GHHRD. Coptisine was identified as the ligand of α-glucosidase and baicalin as the ligand of angiotensin-converting enzyme (ACE). Berberine was found to be a dual inhibitor of α-glucosidase and ACE. The results were further verified by enzyme inhibitory assay and molecular docking simulation. The study suggested that our developed strategy would be a powerful tool for screening bioactive components from multi-component and multi-target TCMs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    Science.gov (United States)

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  19. Liquid Chromatography/Mass Spectrometry Reveals the Effect of Lactobacillus Treatment on the Faecal Metabolite Profile of Rats with Chronic Renal Failure.

    Science.gov (United States)

    Wu, Bin; Jiang, Hongli; He, Quan; Wang, Meng; Xue, Jinhong; Liu, Hua; Shi, Kehui; Wei, Meng; Liang, Shanshan; Zhang, Liwen

    2017-01-01

    Chronic kidney disease is accompanied by changes in the gut microbiome and by an increase in the number of gut pathogenic bacteria. The aim of this study was to investigate the difference of the faecal metabolic profiles in rats with uremia, and to determine whether the altered metabolites in the rats with uremia can be restored by Lactobacillus. Thirty rats were randomly divided into 3 groups: sham, uremia and uremia + probiotic (UP) groups. The rats in uremia and UP groups were prepared through surgical renal mass 5/6 ablation. The rats in the UP group received Lactobacillus LB (1 ml, 109 CFU/ml) through gavage every day for 4 weeks. The rats were fed with a standard diet. Faecal samples were analysed through ultra performance liquid chromatography/mass spectrometry. Statistical analyses were performed using MetaboAnalyst and MATLAB. A total of 99, 324 and 177 significantly different ion peaks were selected between sham and uremia groups; sham and UP groups; and uremia and UP groups, respectively. In the 3 groups, 35 significantly altered metabolites were identified; of the 35 metabolites, 27 initially increased and then decreased; by contrast, 8 metabolites initially decreased and then increased. The 35 metabolites were subjected to pathway analysis in MetaboAnalyst. Faecal metabolites were significantly altered in rats with uremia; these changes were partially reversed by Lactobacillus. © 2016 S. Karger AG, Basel.

  20. Characterisation of organic compounds in aerosol particles from a finnish forest by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shimmo, Masahiko; Jaentti, Jaana; Hartonen, Kari; Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland); Aalto, Pasi; Kulmala, Markku [Division of Atmospheric Sciences, Department of Physical Sciences, University of Helsinki, P.O. Box 64, 00014, Helsinki (Finland)

    2004-04-01

    During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC-MS. A fraction volume as high as 840 {mu}L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified. (orig.)

  1. An evaluation of liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization for the rapid and simultaneous measurement of carbamate pesticides and organophorus pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Joo; So, Hun Young [Korea Research Institute of Standards and Sceince, Taejon (Korea, Republic of)

    2000-05-01

    Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 {mu}g/mL. The peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to tun. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

  2. Identification and quantification of cannabinoids in Cannabis sativa L. plants by high performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Aizpurua-Olaizola, Oier; Omar, Jone; Navarro, Patricia; Olivares, Maitane; Etxebarria, Nestor; Usobiaga, Aresatz

    2014-11-01

    High performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) has been successfully applied to cannabis plant extracts in order to identify cannabinoid compounds after their quantitative isolation by means of supercritical fluid extraction (SFE). MS conditions were optimized by means of a central composite design (CCD) approach, and the analysis method was fully validated. Six major cannabinoids [tetrahydrocannabinolic acid (THCA), tetrahydrocannabinol (THC), cannabidiol (CBD), tetrahydrocannabivarin (THCV), cannabigerol (CBG), and cannabinol (CBN)] were quantified (RSD Cannabis sativa L. plant varieties and the principal component analysis (PCA) of the resulting data, a clear difference was observed between outdoor and indoor grown plants, which was attributed to a higher concentration of THC, CBN, and CBD in outdoor grown plants.

  3. Simultaneous quantification of 21 water soluble vitamin circulating forms in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Meisser Redeuil, Karine; Longet, Karin; Bénet, Sylvie; Munari, Caroline; Campos-Giménez, Esther

    2015-11-27

    This manuscript reports a validated analytical approach for the quantification of 21 water soluble vitamins and their main circulating forms in human plasma. Isotope dilution-based sample preparation consisted of protein precipitation using acidic methanol enriched with stable isotope labelled internal standards. Separation was achieved by reversed-phase liquid chromatography and detection performed by tandem mass spectrometry in positive electrospray ionization mode. Instrumental lower limits of detection and quantification reached water soluble vitamins in human plasma single donor samples. The present report provides a sensitive and reliable approach for the quantification of water soluble vitamins and main circulating forms in human plasma. In the future, the application of this analytical approach will give more confidence to provide a comprehensive assessment of water soluble vitamins nutritional status and bioavailability studies in humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Simultaneous detection of nine cyanotoxins in drinking water using dual solid-phase extraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Yen, Hung-Kai; Lin, Tsair-Fuh; Liao, Pao-Chi

    2011-08-01

    A solid-phase extraction (SPE)-liquid chromatography (LC)-mass spectrometry (MS) method was developed to concentrate and detect nine cyanotoxins simultaneously, including six microcystins (MCs) congeners, nodularin (NOD), anatoxin-a (ATX) and cylindrospermopsin (CYN), in pure and natural waters. A dual cartridge SPE assembly was tested for the operating parameters of cyanotoxin extraction. A surrogate standard (SS), 1,9-diaminononane, was spiked in all the samples before the SPE extraction, and an internal standard (IS), 2,3,5-trimethylphenyl methyl carbamate, was spiked before LC/MS analysis. The method detection limit (MDL) was 2-100 ng/L for nine cyanotoxins in pure water and was increased by a factor of three to ten in a more complicated water matrix. The recoveries based on SS were between 83 and 104%, while those based on IS were 80-120%. The developed method was successfully employed in analyzing 33 water samples collected from eutrophic lakes, water treatment plants and distribution taps. MCs, NOD, and CYN were detected in the reservoir water, with concentrations as high as 36 μg/L. In addition, for the first time in Taiwan's tap water, CYN was detected at concentrations as high as 8.6 μg/L. Quality control data for the field samples shows that the analytical scheme developed is appropriate for monitoring cyanotoxins. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. A novel liquid chromatography/mass spectrometry method for determination of neurotransmitters in brain tissue: Application to human tauopathies.

    Science.gov (United States)

    Forgacsova, Andrea; Galba, Jaroslav; Garruto, Ralph M; Majerova, Petra; Katina, Stanislav; Kovac, Andrej

    2018-01-15

    Neurotransmitters, small molecules widely distributed in the central nervous system are essential in transmitting electrical signals across neurons via chemical communication. Dysregulation of these chemical signaling molecules is linked to numerous neurological diseases including tauopathies. In this study, a precise and reliable liquid chromatography method was established with tandem mass spectrometry detection for the simultaneous determination of aspartic acid, asparagine, glutamic acid, glutamine, γ-aminobutyric acid, N-acetyl-l-aspartic acid, pyroglutamic acid, acetylcholine and choline in human brain tissue. The method was successfully applied to the analysis of human brain tissues from three different tauopathies; corticobasal degeneration, progressive supranuclear palsy and parkinsonism-dementia complex of Guam. Neurotransmitters were analyzed on ultra-high performance chromatography (UHPLC) using an ethylene bridged hybrid amide column coupled with tandem mass spectrometry (MS/MS). Identification and quantification of neurotransmitters was carried out by ESI+ mass spectrometry detection. We optimized sample preparation to achieve simple and fast extraction of all nine analytes. Our method exhibited an excellent linearity for all analytes (all coefficients of determination >0.99), with inter-day and intra-day precision yielding relative standard deviations 3.2%-11.2% and an accuracy was in range of 92.6%-104.3%. The present study, using the above method, is the first to demonstrate significant alterations of brain neurotransmitters caused by pathological processes in the brain tissues of patient with three different tauopathies. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. DETERMINATION OF MUSHROOM TOXIN ALPHA-AMANITIN IN SERUM BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AFTER SOLID-PHASE EXTRACTION

    Directory of Open Access Journals (Sweden)

    Maja Vujović

    2015-03-01

    Full Text Available Alpha-amanitin is a cyclic peptide which belongs to a large group of mushroom toxins known as amatoxins. Being responsible for the majority of fatal mushroom poisonings, they require rapid detection and excretion from the body fluids. In accordance with these requirements, a simple and an accurate method was developed for successful identification and quantification of alpha-amanitin in serum with electrospray liquid chromatography–mass spectrometry (LC-ESI-MS after collision-induced dissociation. The method conforms to the established International Conference on Harmonization Q2A/Q2B 1996 guidelines on the validation of analytical methods. Linearity, precision, extraction recovery and stability test on blank serum spiked with alpha-amanitin and stored in different conditions met the acceptance criteria. The obtained calibration curve was linear over the concentration range 5-100 ng/mL with a lower limit of quantification (LOQ of 5 ng/mL and limit of detection (LOD of 2.5 ng/mL. The mean intra- and inter-day precision and accuracy were 6.05% and less than ±15% of nominal values, respectively. The neutral solid phase extraction with copolymer hydrophilic–lipophilic balance cartridges was found optimal for sample preparation with the mean recovery of 91.94%. The proposed method demonstrated high sensitivity and selectivity which can be useful both for clinical and forensic toxicology analysis of alpha-amanitin at low concentrations.

  7. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    Science.gov (United States)

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc ® inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. First identification of dimethoxycinnamic acids in human plasma after coffee intake by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Nagy, Kornél; Redeuil, Karine; Williamson, Gary; Rezzi, Serge; Dionisi, Fabiola; Longet, Karin; Destaillats, Frédéric; Renouf, Mathieu

    2011-01-21

    There is a substantial amount of published literature on the bioavailability of various coffee components including the most abundant metabolites, caffeic and ferulic acids. Surprisingly, to date, the appearance of dimethoxycinnamic acid derivatives in humans has not been reported despite the fact that methylated form of catechol-type polyphenols could help maintain, modify or even improve their biological activities. This study reports an LC-MS method for the detection of dimethoxycinnamic acid in human plasma after treatment with an esterase. Liquid chromatography, including the combination of methanol and acetonitrile as organic eluent, was optimized to resolve all interferences and enable reliable detection and identification of 3,4-dimethoxycinnamic and 3,4-dimethoxy-dihydrocinnamic acids. In addition to the good mass accuracy achieved (better than 5 ppm), tandem mass spectrometric and co-chromatography experiments further confirmed the identity of the compounds. The optimized method was applied to analyze samples obtained immediately, 1 and 10 h after coffee ingestion. The results show that in particular 3,4-dimethoxycinnamic acid appears in high abundance (∼380 nM at 60 min) in plasma upon coffee intake, indicating that it is important to consider these derivatives in future bioavailability and bioefficacy studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. N-alkylamide profiling of Achillea ptarmica and Achillea millefolium extracts by liquid and gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Lieselotte Veryser; Lien Taevernier; Evelien Wynendaele; Yannick Verheust; Ann Dumoulin; Bart De Spiegeleer

    2017-01-01

    Achillea millefolium and Achillea ptarmica are both plants belonging to the Asteracea family and are traditionally used for their medicinal properties. It has already been shown that some N-alkylamides (NAAs) are responsible for these pharmacological actions. Therefore, in the present study, the NAA content of the two plants was analytically characterised. Different extracts were prepared from the roots, the leaves, the stems and the flowers. The structures of NAAs have been assigned in ethanolic extracts of Achillea millefolium and Achillea ptarmica using high performance liquid chromatography – electrospray ionisation – mass spectro-metry (HPLC–ESI–MS) and gas chromatography–electron impact–mass spectrometry (GC–EI–MS). Using both analytical techniques, the structures of 14 and 15 NAAs have been assigned in Achillea ptarmica and Achillea millefolium, respectively. Structures of two new NAAs, previously never observed in Achillea ptarmica, were assigned: deca-2E,6Z,8E-trienoic acid 2-methylbutylamide (homospilanthol) or a related isomeric compound and deca-2E,4E-dienoic acid N-methyl isobutylamide. The structure of homospilanthol or a related isomeric compound was also assigned in Achillea millefolium for the first time.

  11. Aspects of matrix effects in applications of liquid chromatography-mass spectrometry to forensic and clinical toxicology--a review.

    Science.gov (United States)

    Peters, Frank T; Remane, Daniela

    2012-06-01

    In the last decade, liquid chromatography coupled to (tandem) mass spectrometry (LC-MS(-MS)) has become a versatile technique with many routine applications in clinical and forensic toxicology. However, it is well-known that ionization in LC-MS(-MS) is prone to so-called matrix effects, i.e., alteration in response due to the presence of co-eluting compounds that may increase (ion enhancement) or reduce (ion suppression) ionization of the analyte. Since the first reports on such matrix effects, numerous papers have been published on this matter and the subject has been reviewed several times. However, none of the existing reviews has specifically addressed aspects of matrix effects of particular interest and relevance to clinical and forensic toxicology, for example matrix effects in methods for multi-analyte or systematic toxicological analysis or matrix effects in (alternative) matrices almost exclusively analyzed in clinical and forensic toxicology, for example meconium, hair, oral fluid, or decomposed samples in postmortem toxicology. This review article will therefore focus on these issues, critically discussing experiments and results of matrix effects in LC-MS(-MS) applications in clinical and forensic toxicology. Moreover, it provides guidance on performance of studies on matrix effects in LC-MS(-MS) procedures in systematic toxicological analysis and postmortem toxicology.

  12. Quantification of abscisic acid in grapevine leaf (Vitis vinifera) by isotope-dilution liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Vilaró, Francisca; Canela-Xandri, Anna; Canela, Ramon

    2006-09-01

    A specific, sensitive, precise, and accurate method for the determination of abscisic acid (ABA) in grapevine leaf tissues is described. The method employs high-performance liquid chromatography and electrospray ionization-mass spectrometry (LC-ESI-MS) in selected ion monitoring mode (SIM) to analyze ABA using a stable isotope-labeled ABA as an internal standard. Absolute recoveries ranged from 72% to 79% using methanol/water pH 5.5 (50:50 v/v) as an extraction solvent. The best efficiency was obtained when the chromatographic separation was carried out by using a porous graphitic carbon (PGC) column. The statistical evaluation of the method was satisfactory in the work range. A relative standard deviation (RDS) of < 5.5% and < 6.0% was obtained for intra-batch and inter-batch comparisons, respectively. As for accuracy, the relative error (%Er) was between -2.7 and 4.3%, and the relative recovery ranged from 95% to 107%.

  13. Spatial Mapping of Protein Abundances in the Mouse Brain by Voxelation Integrated with High-Throughput Liquid Chromatography ? Mass Spectrometry

    International Nuclear Information System (INIS)

    Petyuk, Vladislav A.; Qian, Weijun; Chin, Mark H.; Wang, Haixing H.; Livesay, Eric A.; Monroe, Matthew E.; Adkins, Joshua N.; Jaitly, Navdeep; Anderson, David J.; Camp, David G.; Smith, Desmond J.; Smith, Richard D.

    2007-01-01

    Temporally and spatially resolved mapping of protein abundance patterns within the mammalian brain is of significant interest for understanding brain function and molecular etiologies of neurodegenerative diseases; however, such imaging efforts have been greatly challenged by complexity of the proteome, throughput and sensitivity of applied analytical methodologies, and accurate quantitation of protein abundances across the brain. Here, we describe a methodology for comprehensive spatial proteome mapping that addresses these challenges by employing voxelation integrated with automated microscale sample processing, high-throughput LC system coupled with high resolution Fourier transform ion cyclotron mass spectrometer and a ''universal'' stable isotope labeled reference sample approach for robust quantitation. We applied this methodology as a proof-of-concept trial for the analysis of protein distribution within a single coronal slice of a C57BL/6J mouse brain. For relative quantitation of the protein abundances across the slice, an 18O-isotopically labeled reference sample, derived from a whole control coronal slice from another mouse, was spiked into each voxel sample and stable isotopic intensity ratios were used to obtain measures of relative protein abundances. In total, we generated maps of protein abundance patterns for 1,028 proteins. The significant agreement of the protein distributions with previously reported data supports the validity of this methodology, which opens new opportunities for studying the spatial brain proteome and its dynamics during the course of disease progression and other important biological and associated health aspects in a discovery-driven fashion

  14. Determination of diazepam and its metabolites in serum by the use of liquid chromatography: Mass spectrometry method

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2007-01-01

    Full Text Available Background/Aim. Diazepam is a benzodiazepine anxyolitic. Metabolism of diazepam takes place in liver which generates pharmacologically active metabolites N-desmethyldiazepam, temazepam and oxazepam. The aim of this study was to develop and validate the method of liquid chromatographymass spectrometry (LC-MS for separation and determination of diazepam and its active metabolites in the serum of rats samples after i.p. application of diazepam in a dose of 10 mg/kg. Methods. The serum samples taken from Wistar rats, were used in LC-MS analysis after the application of 10 mg/kg of diazepam i.p. Results. After alkaline extraction from the serum samples with diethylether and separation on a C18 reversed-phase column by using mobile phase methanolglacial acetic acid-water (50:1:49 v/v, diazepam and its metabolites were quantified. Determination was performed in a selective ion monitoring (SIM mode, thereby the other exogenous and endogenous compounds did not interfere with this assay. Diazepam, N-desmethyldiazepam, oxazepam and temazepam were eluted in 14 minutes. The standard curve was linear in the range from 10-2 000 ng/ml. The limits of detection for diazepam, N-desmethyldiazepam, oxazepam and temazepam were 4.37, 3.13, 4.38 and 7.31 ng/ml, respectively. The limits of quantitation for diazepam, Ndesmethyldiazepam, oxazepam and temazepam were 14.58, 10.41, 14.59 and 24.36 ng/ml, respectively. Conclusion. The described LC-MS is a simple, sensitive, specific and accurate method and could be used for routine identification and quantification of small concentrations of diazepam and its metabolites in biological fluids.

  15. Improved detection of multiple environmental antibiotics through an optimized sample extraction strategy in liquid chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi

    2015-12-01

    A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.

  16. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    International Nuclear Information System (INIS)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-01-01

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d_5-Girard reagent P (d_5-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones related

  17. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi, E-mail: yqfeng@whu.edu.cn

    2016-01-28

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d{sub 5}-Girard reagent P (d{sub 5}-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones

  18. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide.

    Science.gov (United States)

    Torma, Attila F; Groves, Kate; Biesenbruch, Sabine; Mussell, Chris; Reid, Alan; Ellison, Steve; Cramer, Rainer; Quaglia, Milena

    2017-08-28

    B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.

  19. Optimization of hydrophilic interaction liquid chromatography/mass spectrometry and development of solid-phase extraction for the determination of paralytic shellfish poisoning toxins.

    Science.gov (United States)

    Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena

    2008-01-01

    The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.

  20. Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography-mass spectrometry vs. liquid chromatography-trapped-ion-mobility-mass spectrometry.

    Science.gov (United States)

    Baglai, Anna; Gargano, Andrea F G; Jordens, Jan; Mengerink, Ynze; Honing, Maarten; van der Wal, Sjoerd; Schoenmakers, Peter J

    2017-12-29

    Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC×LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped-ion-mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC×LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Microwave synthesis of gibberellin acid 3 magnetic molecularly imprinted polymer beads for the trace analysis of gibberellin acids in plant samples by liquid chromatography-mass spectrometry detection.

    Science.gov (United States)

    Zhang, Zhuomin; Tan, Wei; Hu, Yuling; Li, Gongke; Zan, Song

    2012-02-21

    In this study, novel GA3 magnetic molecularly imprinted polymer (mag-MIP) beads were synthesized by a microwave irradiation method, and the beads were applied for the trace analysis of gibberellin acids (GAs) in plant samples including rice and cucumber coupled with high performance liquid chromatography-mass spectrometry (HPLC-MS). The microwave synthetic procedure was optimized in detail. In particular, the interaction between GA3 and functional monomers was further studied for the selection of the optimal functional monomers during synthesis. It can be seen that the interaction between GA3 and acrylamide (AM) finally selected was stronger than that between GA3 and other functional monomers. GA3 mag-MIP beads were characterized by a series of physical tests. GA3 mag-MIP beads had a porous and homogeneous surface morphology with stable chemical, thermal and magnetic properties. Moreover, GA3 mag-MIP beads demonstrated selective and specific absorption behavior for the target compounds during unsaturated extraction, which resulted in a higher extraction capacity (∼708.4 pmol for GA3) and selectivity than GA3 mag-non-imprinted polymer beads. Finally, an analytical method of GA3 mag-AM-MIP bead extraction coupled with HPLC-MS detection was established and applied for the determination of trace GA1, GA3, GA4 and GA7 in rice and cucumber samples. It was satisfactory that GA4 could be actually found to be 121.5 ± 1.4 μg kg(-1) in real rice samples by this novel analytical method. The recoveries of spiked rice and cucumber samples were found to be 76.0-109.1% and 79.9-93.6% with RSDs of 2.8-8.8% and 3.1-7.7% (n = 3), respectively. The proposed method is efficient and applicable for the trace analysis of GAs in complicated plant samples.

  2. Development of isotope dilution-liquid chromatography/mass spectrometry combined with standard addition techniques for the accurate determination of tocopherols in infant formula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joonhee; Jang, Eun-Sil; Kim, Byungjoo, E-mail: byungjoo@kriss.re.kr

    2013-07-17

    Graphical abstract: -- Highlights: •ID-LC/MS method showed biased results for tocopherols analysis in infant formula. •H/D exchange of deuterated tocopherols in sample preparation was the source of bias. •Standard addition (SA)-ID-LC/MS was developed as an alternative to ID-LC/MS. •Details of calculation and uncertainty evaluation of the SA-IDMS were described. •SA-ID-LC/MS showed a higher-order metrological quality as a reference method. -- Abstract: During the development of isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) for tocopherol analysis in infant formula, biased measurement results were observed when deuterium-labeled tocopherols were used as internal standards. It turned out that the biases came from intermolecular H/D exchange and intramolecular H/D scrambling of internal standards in sample preparation processes. Degrees of H/D exchange and scrambling showed considerable dependence on sample matrix. Standard addition-isotope dilution mass spectrometry (SA-IDMS) based on LC/MS was developed in this study to overcome the shortcomings of using deuterium-labeled internal standards while the inherent advantage of isotope dilution techniques is utilized for the accurate recovery correction in sample preparation processes. Details of experimental scheme, calculation equation, and uncertainty evaluation scheme are described in this article. The proposed SA-IDMS method was applied to several infant formula samples to test its validity. The method was proven to have a higher-order metrological quality with providing very accurate and precise measurement results.

  3. Liquid chromatography mass spectrometry determination of perfluoroalkyl acids in environmental solid extracts after phospholipid removal and on-line turbulent flow chromatography purification.

    Science.gov (United States)

    Mazzoni, M; Polesello, S; Rusconi, M; Valsecchi, S

    2016-07-01

    An on-line TFC (Turbulent Flow Chromatography) clean up procedures coupled with UHPLC-MS/MS (Ultra High Performance Liquid Chromatography Mass Spectrometry) multi-residue method was developed for the simultaneous determination of 8 perfluroalkyl carboxylic acids (PFCA, from 5 to 12 carbon atoms) and 3 perfluoroalkyl sulfonic acids (PFSA, from 4 to 8 carbon atoms) in environmental solid matrices. Fast sample preparation procedure was based on a sonication-assisted extraction with acetonitrile. Phospholipids in biological samples were fully removed by an off-line SPE purification before injection, using HybridSPE(®) Phospholipid Ultra cartridges. The development of the on-line TFC clean-up procedure regarded the choice of the stationary phase, the optimization of the mobile phase composition, flow rate and injected volume. The validation of the optimized method included the evaluation of matrix effects, accuracy and reproducibility. Signal suppression in the analysis of fortified extracts ranged from 1 to 60%, and this problem was overcome by using isotopic dilution. Since no certified reference materials were available for PFAS in these matrices, accuracy was evaluated by recoveries on spiked clam samples which were 98-133% for PFCAs and 40-60% for PFSAs. MLDs and MLQs ranged from 0.03 to 0.3ngg(-1) wet weight and from 0.1 to 0.9ngg(-1) wet weight respectively. Repeatability (intra-day precision) and reproducibility (inter-day precision) showed RSD from 3 to 13% and from 4 to 27% respectively. Validated on-line TFC/UHPLC-MS/MS method has been applied for the determination of perfluoroalkyl acids in different solid matrices (sediment, fish, bivalves and bird yolk). Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Galaxy-M: a Galaxy workflow for processing and analyzing direct infusion and liquid chromatography mass spectrometry-based metabolomics data.

    Science.gov (United States)

    Davidson, Robert L; Weber, Ralf J M; Liu, Haoyu; Sharma-Oates, Archana; Viant, Mark R

    2016-01-01

    Metabolomics is increasingly recognized as an invaluable tool in the biological, medical and environmental sciences yet lags behind the methodological maturity of other omics fields. To achieve its full potential, including the integration of multiple omics modalities, the accessibility, standardization and reproducibility of computational metabolomics tools must be improved significantly. Here we present our end-to-end mass spectrometry metabolomics workflow in the widely used platform, Galaxy. Named Galaxy-M, our workflow has been developed for both direct infusion mass spectrometry (DIMS) and liquid chromatography mass spectrometry (LC-MS) metabolomics. The range of tools presented spans from processing of raw data, e.g. peak picking and alignment, through data cleansing, e.g. missing value imputation, to preparation for statistical analysis, e.g. normalization and scaling, and principal components analysis (PCA) with associated statistical evaluation. We demonstrate the ease of using these Galaxy workflows via the analysis of DIMS and LC-MS datasets, and provide PCA scores and associated statistics to help other users to ensure that they can accurately repeat the processing and analysis of these two datasets. Galaxy and data are all provided pre-installed in a virtual machine (VM) that can be downloaded from the GigaDB repository. Additionally, source code, executables and installation instructions are available from GitHub. The Galaxy platform has enabled us to produce an easily accessible and reproducible computational metabolomics workflow. More tools could be added by the community to expand its functionality. We recommend that Galaxy-M workflow files are included within the supplementary information of publications, enabling metabolomics studies to achieve greater reproducibility.

  5. Metabonomics evaluation of urine from rats administered with phorate under long-term and low-level exposure by ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Sun, Xiaowei; Xu, Wei; Zeng, Yan; Hou, Yurong; Guo, Lin; Zhao, Xiujuan; Sun, Changhao

    2014-02-01

    The purpose of this study was to investigate the toxic effect of long-term and low-level exposure to phorate using a metabonomics approach based on ultra-performance liquid chromatography-mass spectrometry (UPLC-MS). Male Wistar rats were given phorate daily in drinking water at low doses of 0.05, 0.15 or 0.45 mg kg⁻¹ body weight (BW) for 24 weeks consecutively. Rats in the control group were given an equivalent volume of drinking water. Compared with the control group, serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), total bilirubin (TBIL), urea nitrogen (BUN) and creatinine (CR) were increased in the middle- and high-dose groups whereas albumin (ALB) and cholinesterase (CHE) were decreased. Urine metabonomics profiles were analyzed by UPLC-MS. Compared with the control group, 12 metabolites were significantly changed in phorate-treated groups. In the negative mode, metabolite intensities of uric acid, suberic acid and citric acid were significantly decreased in the middle- and high-dose groups, whereas indoxyl sulfic acid (indican) and cholic acid were increased. In the positive mode, uric acid, creatinine, kynurenic acid and xanthurenic acid were significantly decreased in the middle- and high-dose groups, but 7-methylguanine (N⁷G) was increased. In both negative and positive modes, diethylthiophosphate (DETP) was significantly increased, which was considered as a biomarker of exposure to phorate. In conclusion, long-term and low-level exposure to phorate can cause disturbances in energy-related metabolism, liver and kidney function, the antioxidant system, and DNA damage. Moreover, more information can be provided on the evaluation of toxicity of phorate using metabonomics combined with clinical chemistry. Copyright © 2012 John Wiley & Sons, Ltd.

  6. A urinary metabonomics analysis of long-term effect of acetochlor exposure on rats by ultra-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Li, Longxue; Wang, Maoqing; Chen, Shuhong; Zhao, Wei; Zhao, Yue; Wang, Xu; Zhang, Yang

    2016-03-01

    The study was to assess the long-term toxic effects of acetochlor on rats. Two different doses (42.96 and 107.4 mg/kg body weight/day) of acetochlor were administered to Wistar rats through their food for over 24 weeks. Rat urine samples were collected at two time-points for the measurements of the metabonomics profiles with ultra-performance liquid chromatography-mass spectrometry (UPLC-MSMS). The results of clinical chemistry and histopathology suggested that long-term use of acetochlor in rats caused liver and kidney damage, and dysfunction of antioxidant system. The urinary metabonomics analysis indicated that the high and low-dose exposure of acetochlor could cause alterations of these metabonomics in urine in the rat. Significant changes of the levels of hippuric acid (0.403-fold decrease), citric acid (0.430-fold decrease), pantothenic acid (0.486-fold decrease), uracil (0.419-fold decrease), β-Alanine (0.325-fold decrease), nonanedioic acid (0.445-fold decrease), L-tyrosine (0.410-fold decrease), D-glucuronic acid (8.389-fold increase) and 2-ethyl-6-methyl-N-methyl-2-chloro-acetanilide in urine were observed. In addition, it may interfere with the fatty acid synthesis, the pyrimidine degradation and pantothenate biosynthesis. The level of 2-ethyl-6-methyl-N-methyl-2-chloro-acetanilide is detected in all treated groups which is not found in the control groups, indicating which can be used as an early, sensitive marker of acetochlor exposure in rat. This study illustrates the important utility of metabonomics approaches to understand the toxicity of long-term exposure of acetochlor. Copyright © 2015. Published by Elsevier Inc.

  7. Molecularly imprinted solid phase extraction using stable isotope labeled compounds as template and liquid chromatography-mass spectrometry for trace analysis of bisphenol A in water sample

    International Nuclear Information System (INIS)

    Kawaguchi, Migaku; Hayatsu, Yoshio; Nakata, Hisao; Ishii, Yumiko; Ito, Rie; Saito, Koichi; Nakazawa, Hiroyuki

    2005-01-01

    We have developed a molecularly imprinted polymer (MIP) using a stable isotope labeled compound as the template molecule and called it the ''isotope molecularly imprinted polymer'' (IMIP). In this study, bisphenol A (BPA) was used as the model compound. None imprinted polymer (NIP), MIP, dummy molecularly imprinted polymer (DMIP) and IMIP were prepared by the suspension polymerization method using without template, BPA, 4-tert-butylphenol (BP) and bisphenol A-d 16 (BPA-d 16 ), respectively. The polymers were subjected to molecularly imprinted solid phase extraction (MI-SPE), and the extracted samples were subjected to liquid chromatography-mass spectrometry (LC-MS). Although the leakage of BPA-d 16 from the IMIP was observed and that of BPA was not observed. The selectivity factors of MIP and IMIP for BPA were 4.45 and 4.43, respectively. Therefore, IMIP had the same molecular recognition ability as MIP. When MI-SPE with IMIP was used and followed by LC-MS in the analysis of river water sample, the detection limit of BPA was 1 ppt with high sensitivity. Moreover, the average recovery was higher than 99.8% (R.S.D.: 3.7%) by using bisphenol A- 13 C 12 (BPA- 13 C 12 ) as the surrogate standard. In addition, the IMIP were employed in MI-SPE of BPA in river water sample by LC-MS. The concentration of BPA in the river water sample was determined to be 32 pg ml -1 . We confirmed that it was possible to measure trace amounts of a target analyte by MI-SPE using IMIP

  8. The toxicity of 3-chloropropane-1,2-dipalmitate in Wistar rats and a metabonomics analysis of rat urine by ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Jianshuang; Wang, Sen; Wang, Maoqing; Shi, Wenxiu; Du, Xiaoyan; Sun, Changhao

    2013-11-25

    3-Monochloropropane-1,2-diol(3-MCPD) fatty acid esters can release free 3-MCPD in a certain condition. Free 3-MCPD is a well-known food contaminant and is toxicological well characterized, however, in contrast to free 3-MCPD, the toxicological characterization of 3-MCPD fatty acid esters is puzzling. In this study, toxicological and metabonomics studies of 3-chloropropane-1,2-dipalmitate(3-MCPD dipalmitate) were carried out based on an acute oral toxicity test, a 90-day feeding test and ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) analysis. The LD50 value of 3-MCPD dipalmitate was determined to be 1780 mg/kg body weight (bw) for Wistar rats. The results of the 90-day feeding test in male Wistar rats showed that 3-MCPD dipalmitate caused a significant increase in blood urea nitrogen and creatinine in the high-dose group (267 mg/kg bw/day) compared to control rats. Renal tubular epithelium cell degeneration and renal tubular hyaline cast accumulation were the major histopathological changes in rats administered 3-MCPD dipalmitate. Urine samples obtained after the 90-day feeding test and analyzed by UPLC-MS showed that the differences in metabolic profiles between control and treated rats were clearly distinguished by partial least squares-discriminant analysis (PLS-DA) of the chromatographic data. Five metabolite biomarkers which had earlier and significant variations had been identified, they were first considered to be the early, sensitive biomarkers in evaluating the effect of 3-MCPD dipalmitate exposure, and the possible mechanism of these biomarkers variation was elucidated. The combination of histopathological examination, clinical chemistry and metabolomics analyses in rats resulted in a systematic and comprehensive assessment of the long-term toxicity of 3-MCPD dipalmitate. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Calculation and mitigation of isotopic interferences in liquid chromatography-mass spectrometry/mass spectrometry assays and its application in supporting microdose absolute bioavailability studies.

    Science.gov (United States)

    Gu, Huidong; Wang, Jian; Aubry, Anne-Françoise; Jiang, Hao; Zeng, Jianing; Easter, John; Wang, Jun-sheng; Dockens, Randy; Bifano, Marc; Burrell, Richard; Arnold, Mark E

    2012-06-05

    A methodology for the accurate calculation and mitigation of isotopic interferences in liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays and its application in supporting microdose absolute bioavailability studies are reported for the first time. For simplicity, this calculation methodology and the strategy to minimize the isotopic interference are demonstrated using a simple molecule entity, then applied to actual development drugs. The exact isotopic interferences calculated with this methodology were often much less than the traditionally used, overestimated isotopic interferences simply based on the molecular isotope abundance. One application of the methodology is the selection of a stable isotopically labeled internal standard (SIL-IS) for an LC-MS/MS bioanalytical assay. The second application is the selection of an SIL analogue for use in intravenous (i.v.) microdosing for the determination of absolute bioavailability. In the case of microdosing, the traditional approach of calculating isotopic interferences can result in selecting a labeling scheme that overlabels the i.v.-dosed drug or leads to incorrect conclusions on the feasibility of using an SIL drug and analysis by LC-MS/MS. The methodology presented here can guide the synthesis by accurately calculating the isotopic interferences when labeling at different positions, using different selective reaction monitoring (SRM) transitions or adding more labeling positions. This methodology has been successfully applied to the selection of the labeled i.v.-dosed drugs for use in two microdose absolute bioavailability studies, before initiating the chemical synthesis. With this methodology, significant time and cost saving can be achieved in supporting microdose absolute bioavailability studies with stable labeled drugs.

  10. Monitoring of estrogens, pesticides and bisphenol A in natural waters and drinking water treatment plants by solid-phase extraction-liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià

    2004-08-06

    A multi-residue analytical method has been developed for the determination of various classes of selected endocrine disruptors. This method allows the simultaneous extraction and quantification of different estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol diacetate, estrone-3-sulfate, ethynyl estradiol and diethylstilbestrol), pesticides (atrazine, simazine, desethylatrazine, isoproturon and diuron), and bisphenol A in natural waters. In the method developed, 500 ml of water are preconcentrated on LiChrolut RP-18 cartridges. Further analysis is carried out by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionisation (APCI) in the positive ion mode for determination of pesticides and electrospray in the negative ionisation mode for determination of estrogens and bisphenol A. Recoveries for most compounds were between 90 and 119%, except for bisphenol A (81%) and diethylstilbestrol (70%), with relative standard deviations below 20%. Limits of detection ranged between 2 and 15 ng/l. The method was used to study the occurrence of the selected pollutants in surface and groundwater used for abstraction of drinking water in a waterworks and to evaluate the removal efficiency of the different water treatments applied. Water samples from the river, the aquifer, and after each treatment stage (sand filtration, ozonation, activated carbon filtration and post-chlorination) were taken monthly from February to August of 2002. The presence in river water of atrazine, simazine, diuron and bisphenol A were relatively frequent at concentrations usually below 0.1 microg/l. Lower levels, below 0.02 microg/l, were usual for isoproturon. Estrone-3-sulfate and estrone were detected occasionally in the river. Most of the compounds were completely removed during the water treatment, especially after activated carbon filtration.

  11. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  12. Investigation of the presence of β-hydroxy-β-methylbutyric acid and α-hydroxyisocaproic acid in bovine whole milk and fermented dairy products by a validated liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    Ehling, Stefan; Reddy, Todime M

    2014-02-19

    A simple, rugged, quantitative, and confirmatory method based on liquid chromatography-mass spectrometry was developed and comprehensively validated for the analysis of the leucine metabolites β-hydroxy-β-methylbutyric acid (HMB) and α-hydroxyisocaproic acid (HICA) in bovine whole milk and yogurt. Mean accuracy (90-110% for HMB and 85-115% for HICA) and total precision (dairy products with HMB and/or HICA appears to be justified.

  13. High-throughput characterization of sediment organic matter by pyrolysis-gas chromatography/mass spectrometry and multivariate curve resolution: A promising analytical tool in (paleo)limnology.

    Science.gov (United States)

    Tolu, Julie; Gerber, Lorenz; Boily, Jean-François; Bindler, Richard

    2015-06-23

    Molecular-level chemical information about organic matter (OM) in sediments helps to establish the sources of OM and the prevalent degradation/diagenetic processes, both essential for understanding the cycling of carbon (C) and of the elements associated with OM (toxic trace metals and nutrients) in lake ecosystems. Ideally, analytical methods for characterizing OM should allow high sample throughput, consume small amounts of sample and yield relevant chemical information, which are essential for multidisciplinary, high-temporal resolution and/or large spatial scale investigations. We have developed a high-throughput analytical method based on pyrolysis-gas chromatography/mass spectrometry and automated data processing to characterize sedimentary OM in sediments. Our method consumes 200 μg of freeze-dried and ground sediment sample. Pyrolysis was performed at 450°C, which was found to avoid degradation of specific biomarkers (e.g., lignin compounds, fresh carbohydrates/cellulose) compared to 650°C, which is in the range of temperatures commonly applied for environmental samples. The optimization was conducted using the top ten sediment samples of an annually resolved sediment record (containing 16-18% and 1.3-1.9% of total carbon and nitrogen, respectively). Several hundred pyrolytic compound peaks were detected of which over 200 were identified, which represent different classes of organic compounds (i.e., n-alkanes, n-alkenes, 2-ketones, carboxylic acids, carbohydrates, proteins, other N compounds, (methoxy)phenols, (poly)aromatics, chlorophyll and steroids/hopanoids). Technical reproducibility measured as relative standard deviation of the identified peaks in triplicate analyses was 5.5±4.3%, with 90% of the RSD values within 10% and 98% within 15%. Finally, a multivariate calibration model was calculated between the pyrolytic degradation compounds and the sediment depth (i.e., sediment age), which is a function of degradation processes and changes in OM

  14. Determination of anabolic steroids in human urine by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Saito, Keita; Yagi, Katsuharu; Ishizaki, Atsushi; Kataoka, Hiroyuki

    2010-09-05

    A simple, rapid and sensitive method was developed for determining the presence of seven anabolic steroids (boldenone, nandrolone, testosterone, methyltestosterone, epiandrosterone, androsterone, and atnozolol) in human urine. Glucuronide-conjugates of these compounds were hydrolyzed with beta-glucuronidase. The anabolic steroids were analyzed by on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). The steroids were separated within 14 min by high performance liquid chromatography using a Chromolith RP-18e column and 5 mM ammonium formate/methanol (35/65, v/v) as a mobile phase at a flow rate of 1.0 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for the MS detection of these compounds. The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 microL using a Supel-Q PLOT capillary column for the extraction. The extracted compounds could be desorbed readily from the capillary column by flow of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS with SIM mode detection, good linearity of the calibration curve (r>0.995) was obtained in the concentration range of 0.5-20 ng/mL, except for stanozolol. The detection limits (S/N=3) of anabolic steroids were in the range 9-182 pg/mL and the proposed method showed 20-33-fold higher sensitivity than the direct injection method. The within-day and between-day precisions were below 4.0% and 7.3% (n=5), respectively. This method was applied successfully to the analysis of urine samples without the interference peaks. The recovery rates of anabolic steroids spiked into urine samples were above 85%. This method is useful to analyze the urinary levels of these compounds in anti-doping tests. 2010 Elsevier B.V. All rights reserved.

  15. Analysis of chemical warfare agents in organic liquid samples with magnetic dispersive solid phase extraction and gas chromatography mass spectrometry for verification of the chemical weapons convention.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud, Raghavender D; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-05-27

    A simple, sensitive and low temperature sample preparation method is developed for detection and identification of Chemical Warfare Agents (CWAs) and scheduled esters in organic liquid using magnetic dispersive solid phase extraction (MDSPE) followed by gas chromatography-mass spectrometry analysis. The method utilizes Iron oxide@Poly(methacrylic acid-co-ethylene glycol dimethacrylate) resin (Fe2O3@Poly(MAA-co-EGDMA)) as sorbent. Variants of these sorbents were prepared by precipitation polymerization of methacrylic acid-co-ethylene glycol dimethacrylate (MAA-co-EGDMA) onto Fe2O3 nanoparticles. Fe2O3@poly(MAA-co-EGDMA) with 20% MAA showed highest recovery of analytes. Extractions were performed with magnetic microspheres by MDSPE. Parameters affecting the extraction efficiency were studied and optimized. Under the optimized conditions, method showed linearity in the range of 0.1-3.0μgmL(-1) (r(2)=0.9966-0.9987). The repeatability and reproducibility (relative standard deviations (RSDs) %) were in the range of 4.5-7.6% and 3.4-6.2% respectively for organophosphorous esters in dodecane. Limits of detection (S/N=3/1) and limit of quantification (S/N=10/1) were found to be in the range of 0.05-0.1μgmL(-1) and 0.1-0.12μgmL(-1) respectively in SIM mode for selected analytes. The method was successfully validated and applied to the extraction and identification of targeted analytes from three different organic liquids i.e. n-hexane, dodecane and silicon oil. Recoveries ranged from 58.7 to 97.3% and 53.8 to 95.5% at 3μgmL(-1) and 1μgmL(-1) spiking concentrations. Detection of diethyl methylphosphonate (DEMP) and O-Ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) in samples provided by the Organization for Prohibition of Chemical Weapons Proficiency Test (OPCW-PT) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Stable isotope N-phosphoryl amino acids labeling for quantitative profiling of amine-containing metabolites using liquid chromatography mass spectrometry.

    Science.gov (United States)

    Zhang, Shanshan; Shi, Jinwen; Shan, Changkai; Huang, Chengting; Wu, Yile; Ding, Rong; Xue, Yuhua; Liu, Wen; Zhou, Qiang; Zhao, Yufen; Xu, Pengxiang; Gao, Xiang

    2017-07-25

    Stable isotope chemical labeling liquid chromatography-mass spectrometry (LC-MS) is a powerful strategy for comprehensive metabolomics profiling, which can improve metabolites coverage and quantitative information for exploration of metabolic regulation in complex biological systems. In the current work, a novel stable isotope N-phosphoryl amino acids labeling strategy (SIPAL) has been successful developed for quantitative profiling of amine-containing metabolites in urine based on organic phosphorus chemistry. Two isotopic reagents, 16 O 2 - and 18 O 2 -N-diisopropyl phosphoryl l-alanine N-hydroxysuccinimide esters ( 16 O/ 18 O-DIPP-L-Ala-NHS), were firstly synthesized in high yields for labeling the amine-containing metabolites. The performance of SIPAL strategy was tested by analyzing standard samples including 20 l-amino acids, 10 d-amino acids and small peptides by using LC-MS. We observed highly efficient and selective labeling for SIPAL strategy within 15 min in a one-pot derivatization reaction under aqueous reaction conditions. The introduction of a neutral phosphate group at N-terminus can increase the proton affinity and overall hydrophobicity of targeted metabolites, leading to the better ionization efficiency in electrospray ionization processes and chromatographic separations of hydrophilic metabolites on reversed-phase column. Furthermore, the chiral metabolites, such as d-amino acids, could be converted to diastereomers after SIPAL and successfully separated on regular reversed-phase column. The chirality of labeled enantiomers can be determined by using different detection methods such as 31 P NMR, UV, and MS, demonstrating the potential application of SIPAL strategy. In addition, absolute quantification of chiral metabolites in biological samples can be easily achieved by using SIPAL strategy. For this purpose, urine samples collected from a healthy volunteer were analyzed by using LC-ESI-Orbitrap MS. Over 300 pairs of different amine

  17. Enhancement of sensitivity in the determination of organic trace compounds in complex matrices with liquid chromatography-mass spectrometry (LC-MS)

    International Nuclear Information System (INIS)

    Mascher, D.G.

    2002-05-01

    The PhD-thesis deals with 'enhancement of sensitivity in the determination of organic trace compounds in complex matrices with liquid chromatography-mass spectrometry (LC-MS)'. Almost the most important factor is the enhancement of the ionization yield with Atmospheric Pressure Chemical Ionization (APCI) or Electrospray Ionization (ESI) in LC-MS. Ionization yields of different compounds can vary by a factor of 10000. Three ways to solve this problem of little ionization yield were tried: 1) Modification of the mobile phase in HPLC 2) Chemical modification of the analytes 3) A new type of ionization called Atmospheric Pressure Photo Ionization (APPI). ad 1) By using specific additives to mobile phases ion suppression that might derive from an ion pair reagent that was necessary for chromatography could be omitted. General remarks cannot be done. ad 2) Chemical modification or so called derivatization is well known for UV- and fluorescence-detection for a long period of time. As substances containing nitrogene (e.g. primary, secondary or tertiary amines) often have good ionization yields, poor or relatively poor ionizable substances like carboxylic acids, sugars and partially phenolic steroids were used as analytes for derivatization reactions. By using Dansyl as Dansylchlorid or Dansylhydrazine a basic derivatization agent could be found that ionizes very well. A 200 times more sensitive determination of estrogenes is possible after derivatization with Dansylchlorid. Using a tandem-mass-spectrometer a lower limit of quantification of 2 pg/mL plasma could be reached by using 1 mL of plasma. For ketones like carvon and campher an enhancement by a factor of 500 and 4000 could be reached by using Dansylhydrazine as the derivatization agent. For fatty acids DMEQ as derivatization agent enhanced the sensitivity by a factor of 20 to 100. ad 3) APPI as a new ionization mode showed really good results for specific molecules. Relatively unpolar substances as diphenylsulfide

  18. Determination of caffeoylquinic acids in feed and related products by focused ultrasound solid-liquid extraction and ultra-high performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Tena, M T; Martínez-Moral, M P; Cardozo, P W

    2015-06-26

    A method to determine caffeoylquinic acids (CQAs) in three sources (herbal extract, feed additive and finished feed) using for the first time focused ultrasound solid-liquid extraction (FUSLE) followed by ultra-high performance liquid chromatography (UPLC) coupled to quadrupole-time of flight mass spectrometry is presented. Pressurized liquid extraction (PLE) was also tested as extraction technique but it was discarded because cynarin was not stable under temperature values used in PLE. The separation of the CQAs isomers was carried out in only seven minutes. FUSLE variables such as extraction solvent, power and time were optimized by a central composite design. Under optimal conditions, FUSLE extraction was performed with 8mL of an 83:17 methanol-water mixture for 30s at a power of 60%. Only two extraction steps were found necessary to recover analytes quantitatively. Sensitivity, linearity, accuracy and precision were established. Matrix effect was studied for each type of sample. It was not detected for mono-CQAs, whereas the cynarin signal was strongly decreased due to ionization suppression in presence of matrix components; so the quantification by standard addition was mandatory for the determination of di-caffeoylquinic acids. Finally, the method was applied to the analysis of herbal extracts, feed additives and finished feed. In all samples, chlorogenic acid was the predominant CQA, followed by criptochlorogenic acid, neochlorogenic acid and cynarin. The method allows an efficient determination of chlorogenic acid with good recovery rates. Therefore, it may be used for screening of raw material and for process and quality control in feed manufacture. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui

    2017-08-01

    Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Method for the determination of carboxylic acids in industrial effluents using dispersive liquid-liquid microextraction with injection port derivatization gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, Andre; Boczkaj, Grzegorz

    2017-09-29

    The paper presents a new method for the determination of 15 carboxylic acids in samples of postoxidative effluents from the production of petroleum bitumens using ion-pair dispersive liquid-liquid microextraction and gas chromatography coupled to mass spectrometry with injection port derivatization. Several parameters related to the extraction and derivatization efficiency were optimized. Under optimized experimental conditions, the obtained limit of detection and quantification ranged from 0.0069 to 1.12μg/mL and 0.014 to 2.24μg/mL, respectively. The precision (RSD ranged 1.29-6.42%) and recovery (69.43-125.79%) were satisfactory. Nine carboxylic acids at concentrations ranging from 0.10μg/mL to 15.06μg/mL were determined in the raw wastewater and in samples of effluents treated by various oxidation methods. The studies revealed a substantial increase of concentration of benzoic acids, in samples of wastewater after treatment, which confirms the need of carboxylic acids monitoring during industrial effluent treatment processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Method for the simultaneous determination of monoaromatic and polycyclic aromatic hydrocarbons in industrial effluents using dispersive liquid-liquid microextraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, André; Boczkaj, Grzegorz

    2018-02-23

    We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid-liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1-84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono- and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Determination of phthalate esters in distillates by ultrasound-vortex-assisted dispersive liquid-liquid micro-extraction (USVADLLME) coupled with gas chromatography/mass spectrometry.

    Science.gov (United States)

    Montevecchi, Giuseppe; Masino, Francesca; Zanasi, Luca; Antonelli, Andrea

    2017-04-15

    A method for the extraction of phthalate esters (PAEs) by Ultrasound-Vortex-Assisted Dispersive Liquid-Liquid Micro-Extraction (USVADLLME) approach was optimised and applied for the first time to a historical series of brandies. These contaminants are widely spread in the environment as a consequence of about half century of use in different fields of applications. The concern about these substances and the recent legal restrictions of China in distillates import need a quick and sensitive method for their quantification. The proposed method, moreover, is environmentally oriented due to the disposal of micro-quantities of solvent required. In fact, sub-ppm-limits of detection were achieved with a solvent volume as low as 160μL. The analysed samples were within the legal limits, except for some very ancient brandies whose contamination was probably due to a PAEs concentration effect as a consequence of long ageing and for the use of plastic pipelines no more operative. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Development of salt and pH-induced solidified floating organic droplets homogeneous liquid-liquid microextraction for extraction of ten pyrethroid insecticides in fresh fruits and fruit juices followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Torbati, Mohammadali; Farajzadeh, Mir Ali; Torbati, Mostafa; Nabil, Ali Akbar Alizadeh; Mohebbi, Ali; Afshar Mogaddam, Mohammad Reza

    2018-01-01

    A new microextraction method named salt and pH-induced homogeneous liquid-liquid microextraction has been developed in a home-made extraction device for the extraction and preconcentration of some pyrethroid insecticides from different fruit juice samples prior to gas chromatography-mass spectrometry. In the present work, an extraction device made from two parallel glass tubes with different lengths and diameters was used in the microextraction procedure. In this method, a homogeneous solution of a sample solution and an extraction solvent (pivalic acid) was broken by performing an acid-base reaction and the extraction solvent was produced in whole of the solution. The produced droplets of the extraction solvent went up through the solution and solidified using an ice-bath. They were collected without centrifugation step. Under the optimum conditions, limits of detection and quantification were obtained in the ranges of 0.006-0.038, and 0.023-0.134ngmL -1 , respectively. The enrichment factors and extraction recoveries of the selected analytes ranged from 365-460 to 73-92%, respectively. The relative standard deviations were lower than 9% for intra- (n = 6) and inter-day (n = 4) precisions at a concentration of 1ngmL -1 of each analyte. Finally, some fruit juice samples were effectively analyzed by the proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos

    2013-06-30

    A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  5. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  6. Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction

    Science.gov (United States)

    Johnsen, Elin; Leknes, Siri; Wilson, Steven Ray; Lundanes, Elsa

    2015-03-01

    Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.

  7. Polybrominated diphenyl ethers (PBDEs) contents in house and car dust of Portugal by pressurized liquid extraction (PLE) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Cunha, S C; Kalachova, K; Pulkrabova, J; Fernandes, J O; Oliveira, M B P P; Alves, A; Hajslova, J

    2010-03-01

    Dust is the repository of various compounds including flame retardants. In this study an analytical method based on PLE extraction and gas chromatography-mass spectrometry was selected for the analysis of 16 PBDEs congeners in house and car dust samples collected in Portugal. The analytical performance of the method was validated using standard reference material (SRM); values from 90% to 109% and from 2% to 11% were obtained for recovery and precision, respectively. The PBDE congeners distribution in whole and sieved fractions of the dust samples, as well as influence of the source on the levels of these contaminants, were obtained. The wide range of PBDEs contents found in the dust samples indicates heterogeneous levels of contamination in these matrices. The clearest feature of the results obtained was that Deca-BDE was the main PBDE in both house and car dust samples. The total PBDEs measured in house dust (ranging from 34 to 1928 ng g(-1)) was lower than those found in car dust (ranging from 193 to 22955 ng g(-1)). However, house dust provides a major contribution to human exposure due to the time spent there, much higher than in cars. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  8. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  9. Prediction of biotransformation products of the fungicide fluopyram by electrochemistry coupled online to liquid chromatography-mass spectrometry and comparison with in vitro microsomal assays.

    Science.gov (United States)

    Mekonnen, Tessema F; Panne, Ulrich; Koch, Matthias

    2018-04-01

    Biotransformation processes of fluopyram (FLP), a new succinate dehydrogenase inhibitor (SDHI) fungicide, were investigated by electrochemistry (EC) coupled online to liquid chromatography (LC) and electrospray mass spectrometry (ESI-MS). Oxidative phase I metabolite production was achieved using an electrochemical flow-through cell equipped with a boron-doped diamond (BDD) electrode. Structural elucidation and prediction of oxidative metabolism pathways were assured by retention time, isotopic patterns, fragmentation, and accurate mass measurements using EC/LC/MS, LC-MS/MS, and/or high-resolution mass spectrometry (HRMS). The results obtained by EC were compared with conventional in vitro studies by incubating FLP with rat and human liver microsomes (RLM, HLM). Known phase I metabolites of FLP (benzamide, benzoic acid, 7-hydroxyl, 8-hydroxyl, 7,8-dihydroxyl FLP, lactam FLP, pyridyl acetic acid, and Z/E-olefin FLP) were successfully simulated by EC/LC/MS. New metabolites including an imide, hydroxyl lactam, and 7-hydroxyl pyridyl acetic acid oxidative metabolites were predicted for the first time in our study using EC/LC/MS and liver microsomes. We found oxidation by dechlorination to be one of the major metabolism mechanisms of FLP. Thus, our results revealed that EC/LC/MS-based metabolic elucidation was more advantageous on time and cost of analysis and enabled matrix-free detection with valuable information about the mechanisms and intermediates of metabolism processes. Graphical abstract Oxidative metabolism of fluopyram.

  10. Determination of growth hormone releasing peptides (GHRP) and their major metabolites in human urine for doping controls by means of liquid chromatography mass spectrometry.

    Science.gov (United States)

    Thomas, Andreas; Höppner, Sebastian; Geyer, Hans; Schänzer, Wilhelm; Petrou, Michael; Kwiatkowska, Dorota; Pokrywka, Andrzej; Thevis, Mario

    2011-08-01

    A family of small peptides has reached the focus of doping controls representing a comparably new strategy for cheating sportsmen. These growth hormone releasing peptides (GHRP) are orally active and induce an increased production of endogenous growth hormone (GH). While the established test for exogenous GH fails, the misuse of these prohibited substances remains unrecognized. The present study provides data for the efficient extraction of a variety of known drug candidates (GHRP-1, GHRP-2, GHRP-4, GHRP-5, GHRP-6, alexamorelin, ipamorelin, and hexarelin) from human urine with subsequent mass spectrometric detection after liquid chromatographic separation. The used method potentially enables the retrospective evaluation of the acquired data for unknown metabolites by means of a non-targeted approach with high-resolution/high-accuracy full-scan mass spectrometry with additional higher collision energy dissociation experiments. This is of great importance due to the currently unknown metabolism of most of the targets and, thus, the method is focused on the intact peptidic drugs. Only the already characterised major metabolite of GHRP-2 (D-Ala-D-2-naphthylAla-L-Ala, as well as its stable isotope-labelled analogue) was synthesised and implemented in the detection assay. Method validation for qualitative purpose was performed with respect to specificity, precision (<20%), intermediate precision (<20%), recovery (47-95%), limit of detection (0.2-1 ng/mL), linearity, ion suppression and stability. Two stable isotope-labelled internal standards were used (deuterium-labelled GHRP-4 and GHRP-2 metabolite). The proof-of-principle was obtained by the analysis of excretion study urine samples obtained from a single oral administration of 10 mg of GHRP-2. Here, the known metabolite was detectable over 20 h after administration while the intact drug was not observed.

  11. Simultaneous determination of bisphenol A and bisphenol B in beverages and powdered infant formula by dispersive liquid-liquid micro-extraction and heart-cutting multidimensional gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cunha, S C; Almeida, C; Mendes, E; Fernandes, J O

    2011-04-01

    The purpose of this study was to establish a reliable, cost-effective, fast and simple method to quantify simultaneously both bisphenol A (BPA) and bisphenol B (BPB) in liquid food matrixes such as canned beverages (soft drinks and beers) and powdered infant formula using dispersive liquid-liquid micro-extraction (DLLME) with in-situ derivatisation coupled with heart-cutting gas chromatography-mass spectrometry (GC-MS). For the optimisation of the DLLME procedure different amounts of various extractive and dispersive solvents as well as different amounts of the derivative reagent were compared for their effects on extraction efficiency and yields. The optimised procedure consisted of the injection of a mixture containing tetrachloroethylene (extractant), acetonitrile (dispersant) and acetic anhydride (derivatising reagent) directly into an aliquot of beverage samples or into an aqueous extract of powdered milk samples obtained after a pretreatment of the samples. Given the compatibility of the solvents used, and the low volumes involved, the procedure was easily associated with GC-MS end-point determination, which was accomplished by means of an accurate GC dual column (heart-cutting) technique. Careful optimisation of heart-cutting GC-MS conditions, namely pressure of front and auxiliary inlets, have resulted in a good analytical performance. The linearity of the matrix-matched calibration curves was acceptable, with coefficients of determination (r2) always higher than 0.99. Average recoveries of the BPA and BPB spiked at two concentration levels into beverages and powdered infant formula ranged from 68% to 114% and the relative standard deviation (RSD) was canned beverages were 5.0 and 2.0 ng l(-1) for BPA and BPB, respectively, whereas LOD in powdered infant formula were 60.0 and 30.0 ng l(-1), respectively. The limits of quantification (LOQ) in canned beverages were 10.0 and 7.0 ng l-1 for BPA and BPB, respectively, whereas LOQ in powdered infant formula were

  12. Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

    Science.gov (United States)

    Brunswick, Pamela; Shang, Dayue; van Aggelen, Graham; Hindle, Ralph; Hewitt, L Mark; Frank, Richard A; Haberl, Maxine; Kim, Marcus

    2015-07-31

    A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed

  13. Analysis of recombinant Schistosoma mansoni antigen rSmp28 by on-line liquid chromatography-mass spectrometry combined with sodium dodecyl sulfate polyacrylamide gel electrophoresis

    NARCIS (Netherlands)

    Klarskov, K.; Roecklin, D.; Bouchon, B.; Sabatie, J.; Van Dorsselaer, A.; Bischoff, Rainer

    1994-01-01

    A recombinant Schistosoma mansoni antigen produced in Saccharomyces cerevisiae and purified by glutathione-Sepharose affinity chromatography was analyzed by tryptic peptide mapping using on-line reversed-phase high-performance liquid chromatography pneumatically assisted electrospray mass

  14. Tandem Extraction/Liquid Chromatography-Mass Spectrometry Protocol for the Analysis of Acrylamide and Surfactant-related Compounds in Complex Aqueous Environmental Samples

    Science.gov (United States)

    The development of a liquid chromatography‐mass spectrometry (LC‐MS)‐based strategy for the detection and quantitation of acrylamide and surfactant‐related compounds in aqueous complex environmental samples.

  15. Development and validation of confirmatory method for analysis of nitrofuran metabolites in milk, honey, poultry meat and fish by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fatih Alkan

    2016-03-01

    Full Text Available In this study we have devoloped and validated a confirmatory analysis method for nitrofuran metabolites, which is in accordance with European Commission Decision 2002/657/EC requirements. Nitrofuran metabolites in honey, milk, poultry meat and fish samples were acidic hydrolised followed by derivatisation with nitrobenzaldehyde and liquid-liquid extracted with ethylacetate. The quantitative and confirmative determination of nitrofuran metbolites was performed by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS in the positive ion mode. In-house method validation was performed and reported data of validation (specificity, linearity, recovery, CCα and CCβ. The advantage of this method is that it avoids the use of clean-up by Solid-Phase Extraction (SPE. Furthermore, low levels of nitrofuran metabolites are detectable and quantitatively confirmed at a rapid rate in all samples.

  16. A liquid chromatography-mass spectrometry method for the quantification of bioavailability and bioconversion of beta-carotene to retinol in humans

    NARCIS (Netherlands)

    Yan Wang,; Xiaoying Xu,; Lieshout, van M.; West, C.E.; Lugtenburg, J.; Verhoeven, M.A.; Creemers, A.F.L.

    2000-01-01

    A method based on high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (APCI LC-MS) was developed for the quantification of the bioavailability of retinyl palmitate and -carotene and the bioconversion of -carotene to retinol in humans. Following oral

  17. Variability of matrix effects in liquid and gas chromatography - mass spectrometry analysis of pesticide residues after QuEChERS sample preparation of different food crops

    Science.gov (United States)

    Gas and liquid chromatography (GC and LC) coupled to sophisticated mass spectrometry (MS) instruments are among the most powerful analytical tools currently available to monitor pesticide residues in food, among other applications. However, both GC-MS and LC-MS are susceptible to matrix effects whi...

  18. Factors That Contribute to Assay Variation in Quantitative Analysis of Sex Steroid Hormones Using Liquid and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Xu, Xia; Veenstra, Timothy D.

    2012-01-01

    The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…

  19. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group?Determination of acetamide herbicides and their degradation products in water using online solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, E.A.; Strahan, A.P.

    2003-01-01

    An analytical method for the determination of 6 acetamide herbicides (acetochlor, alachlor, dimethenamid, flufenacet, metolachlor, and propachlor) and 16 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is described in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using octadecylsilane as the solid-phase extraction media on online automated equipment followed by liquid chromatography/mass spectrometry. The method uses only 10 milliliters of sample per injection. Three different water-sample matrices, a reagent-water, a ground-water, and a surface-water sample spiked at 0.10 and 1.0 microgram per liter, were analyzed to determine method performance. Method detection limits ranged from 0.004 to 0.051 microgram per liter for the parent acetamide herbicides and their degradation products. Mean recoveries for the acetamide compounds in the ground- and surface-water samples ranged from 62.3 to 117.4 percent. The secondary amide of acetochlor/metolachlor ethanesulfonic acid (ESA) was recovered at an average rate of 43.5 percent. The mean recoveries for propachlor and propachlor oxanilic acid (OXA) were next lowest, ranging from 62.3 to 95.5 percent. Mean recoveries from reagent-water samples ranged from 90.3 to 118.3 percent for all compounds. Overall the mean of the mean recoveries of all compounds in the three matrices spiked at 0.10 and 1.0 microgram per liter ranged from 89.9 to 100.7 percent, including the secondary amide of acetochlor/metolachlor ESA and the propachlor compounds. The acetamide herbicides and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter. The upper concentration limit is 2.0 micrograms per liter for all compounds without dilution. With the exception of the secondary amide of

  20. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group : determination of triazine and phenylurea herbicides and their degradation products in water using solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Lee, Edward Alan; Strahan, Alex P.; Thurman, Earl Michael

    2002-01-01

    An analytical method for the determination of 7 triazine and phenylurea herbicides and 12 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography/mass spectrometry is presented in this report. Special consideration was given during the development of the method to prevent the formation of degradation products during the analysis. Filtered water samples were analyzed using 0.5 gram graphitized carbon as the solid-phase extraction media followed by liquid chromatography/mass spectrometry. Three different water-sample matrices?ground-water, surface-water, and reagent-water samples?spiked at 0.2 and 2.0 micrograms per liter were analyzed. Method detection limits ranged from 0.013 to 0.168 microgram per liter for the parent triazine herbicides and the triazine degradation products. Method detection limits ranged from 0.042 to 0.141 microgram per liter for the parent phenylurea herbicides and their degradation products. Mean recoveries for the triazine compounds in the ground- and surface-water samples generally ranged from 72.6 to 117.5 percent, but deethyl-cyanazine amide was recovered at 140.5 percent. Mean recoveries from the ground- and surface-water samples for the phenylurea compounds spiked at the 2.0-micrograms-per-liter level ranged from 82.1 to 114.4 percent. The mean recoveries for the phenylureas spiked at 0.2-microgram per liter were less consistent, ranging from 87.0 to 136.0 percent. Mean recoveries from reagent-water samples ranged from 87.0 to 109.5 percent for all compounds. The triazine compounds and their degradation products are reported in concentrations ranging from 0.05 to 2.0 micrograms per liter, with the exception of deethylcyanazine and deethylcyanazine amide which are reported at 0.20 to 2.0 micrograms per liter. The phenylurea compounds and their degradation products are reported in concentrations ranging from 0.20 to 2.0 micrograms per liter. The upper concentration limit was 2

  1. Tracking problems and possible solutions in the quantitative determination of small molecule drugs and metabolites in biological fluids using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bakhtiar, Ray; Majumdar, Tapan K

    2007-01-01

    During the last decade, quantification of low molecular weight molecules using liquid chromatography-tandem mass spectrometry in biological fluids has become a common procedure in many preclinical and clinical laboratories. This overview highlights a number of issues involving "small molecule drugs", bioanalytical liquid chromatography-tandem mass spectrometry, which are frequently encountered during assay development. In addition, possible solutions to these issues are proposed with examples in some of the case studies. Topics such as chromatographic peak shape, carry-over, cross-talk, standard curve non-linearity, internal standard selection, matrix effect, and metabolite interference are presented. Since plasma is one of the most widely adopted biological fluid in drug discovery and development, the focus of this discussion will be limited to plasma analysis. This article is not intended to be a comprehensive overview and readers are encouraged to refer to the citations herein.

  2. Improved sensitivity using liquid chromatography mass spectrometry (LC-MS) for detection of propyl chloroformate derivatised β-N-methylamino-L-alanine (BMAA) in cyanobacteria

    OpenAIRE

    Esterhuizen-Londt, M; Downing, S; Downing, TG

    2011-01-01

    β-N-methylamino-L-alanine (BMAA) is a difficult molecule to detect, primarily due to its presence in low concentrations in complex matrices. This has resulted in contradictory reports on the presence of BMAA in cyanobacteria. We report improved sensitivity of detection using propyl chloroformate derivatisation, liquid chromatographic (LC) separation, and single quadrupole mass spectrometry (MS) detection. Triple quadrupole mass spectrometry (MS/MS) was used to confirm the identity of BMAA in ...

  3. Qualitative and quantitative characterization of plasma proteins when incorporating traveling wave ion mobility into a liquid chromatography-mass spectrometry workflow for biomarker discovery: use of product ion quantitation as an alternative data analysis tool for label free quantitation.

    Science.gov (United States)

    Daly, Charlotte E; Ng, Leong L; Hakimi, Amirmansoor; Willingale, Richard; Jones, Donald J L

    2014-02-18

    Discovery of protein biomarkers in clinical samples necessitates significant prefractionation prior to liquid chromatography-mass spectrometry (LC-MS) analysis. Integrating traveling wave ion mobility spectrometry (TWIMS) enables in-line gas phase separation which when coupled with nanoflow liquid chromatography and data independent acquisition tandem mass spectrometry, confers significant advantages to the discovery of protein biomarkers by improving separation and inherent sensitivity. Incorporation of TWIMS leads to a packet of concentrated ions which ultimately provides a significant improvement in sensitivity. As a consequence of ion packeting, when present at high concentrations, accurate quantitation of proteins can be affected due to detector saturation effects. Human plasma was analyzed in triplicate using liquid-chromatography data independent acquisition mass spectrometry (LC-DIA-MS) and using liquid-chromatography ion-mobility data independent acquisition mass spectrometry (LC-IM-DIA-MS). The inclusion of TWIMS was assessed for the effect on sample throughput, data integrity, confidence of protein and peptide identification, and dynamic range. The number of identified proteins is significantly increased by an average of 84% while both the precursor and product mass accuracies are maintained between the modalities. Sample dynamic range is also maintained while quantitation is achieved for all but the most abundant proteins by incorporating a novel data interpretation method that allows accurate quantitation to occur. This additional separation is all achieved within a workflow with no discernible deleterious effect on throughput. Consequently, TWIMS greatly enhances proteome coverage and can be reliably used for quantification when using an alternative product ion quantification strategy. Using TWIMS in biomarker discovery in human plasma is thus recommended.

  4. Quantification of 8-α-hydroxy-mutilin as marker residue for tiamulin in rabbit tissues by high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    De Baere, Siegrid; Devreese, Mathias; Maes, An; De Backer, Patrick; Croubels, Siska

    2015-06-01

    For the first time, a sensitive and specific method was developed and fully validated for the quantification of the EU marker residue of tiamulin, 8-α-hydroxy-mutilin, in rabbit muscle and liver tissues using liquid chromatography combined with positive heated electrospray ionization triple quadrupole mass spectrometry. The mass spectrometer was operated in the selected reaction monitoring (SRM) mode with selection of the [M + H](+) ion in both quadrupoles 1 and 3, resulting in the SRM transition m/z 337.25 > 337.25 for quantification. Chromatography was performed using a Hypersil Gold C18 column using a gradient elution program with water and methanol as mobile phases. The sample preparation procedure for the analysis of 8-α-hydroxy-mutilin in liver and muscle samples consisted of three main steps: (1) extraction of the tissue matrix using 0.1 N hydrochloric acid/acetone (50/50, v/v), (2) hydrolysis of tiamulin and metabolites to 8-α-hydroxy-mutilin in alkaline medium at 45 °C, and (3) liquid-liquid extraction in acidic medium using ethyl acetate. This is the first method presenting fully validated results, encompassing a linearity of 50 to 2,000 μg/kg, within-run and between-run accuracy and precision, limit of quantification (50 μg/kg for both muscle and liver tissues), limit of detection (muscle, 11.9 μg/kg; liver, 20.6 μg/kg), extraction recovery (muscle, 66.2%; liver, 75.5%), signal suppression and enhancement (muscle, 51.7%; liver, 43.3%), carryover, applicability and practicability, and stability during storage and analysis. This novel method is therefore sensitive enough to be used for residue depletion studies of tiamulin in rabbits and for food safety monitoring with respect to MRL compliance of residues.

  5. Amphetamines analysis in wastewaters - method performance of solid phase extraction - higher performance liquid chromatography mass spectrometry techniques (SPE-HPLC MS/MS)

    Science.gov (United States)

    Mustapha, Aliru Olajide; Ajao, Usman L

    2011-01-01

    Recently, many articles have reported different levels and distribution of amphetamine hitherto detected in biological fluids now appreciably found in aquatic environment at ng/L levels. Identification and measurement of amphetamine and its metabolites in surface and sewage waters using higher performance liquid chromatographic methodologies in the literatures now on current trend have provided information that are of scientific interest and effectively replaced immunological methods which only suggest the presence of these substances. Active research on both distribution and impacts of this important drug of abuse and related metabolites in the wastewaters are on-going. PMID:27857670

  6. A sensitive liquid chromatography-mass spectrometry method for the simultaneous determination in plasma of pentacyclic triterpenes of Olea europaea L.

    Science.gov (United States)

    Giménez, Estela; Juan, M Emília; Calvo-Melià, Sara; Planas, Joana M

    2017-08-15

    Table olives are especially rich in pentacyclic triterpenic compounds, which exert several biological activities. A crucial step in order to know if these compounds could contribute to the beneficial and healthy properties of this food is their measurement in blood. Therefore, the present study describes a simple and accurate liquid-liquid extraction followed by LC-QqQ-MS analysis for the simultaneous determination of the main pentacyclic triterpenes from Olea europaea L. in rat plasma. The method was validated by the analysis of blank plasma samples spiked with pure compounds, obtaining a linear correlation, adequate sensitivity with a limit of quantification ranging from 1nM for maslinic acid to 10nM for uvaol. Precision and accuracy were lower than 10% in all cases and recoveries were between 95 and 104%. The oral administration of olives to rats and its determination in plasma verified that the established methodology is appropriate for bioavailability studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A liquid chromatography-mass spectrometry method based on class characteristic fragmentation pathways to detect the class of indole-derivative synthetic cannabinoids in biological samples.

    Science.gov (United States)

    Mazzarino, Monica; de la Torre, Xavier; Botrè, Francesco

    2014-07-21

    This article describes a liquid chromatographic/tandem mass spectrometric method, based on the use of precursor ion scan as the acquisition mode, specifically developed to detect indole-derived cannabinoids (phenylacetylindoles, naphthoylindoles and benzoylindoles) in biological fluids (saliva, urine and blood). The method is designed to recognize one or more common "structural markers", corresponding to mass spectral fragments originating from the specific portion of the molecular structure that is common to the aminoalkylindole analogues and that is fundamental for their pharmacological classification. As such, the method is also suitable for detecting unknown substances, provided they contain the targeted portion of the molecular structure. The pre-treatment procedure consists in a liquid/liquid extraction step carried out at neutral pH: this is the only pretreatment in the case of analyses carried out in saliva, while it follows an enzymatic hydrolysis procedure in the case of urine samples, or a protein precipitation step in the case of blood samples. The chromatographic separation is achieved using an octadecyl reverse-phase 5 μm fused-core particle column; while the mass spectrometric detection is carried out by a triple-quadrupole instrument in positive electrospray ionization and precursor ion scan as acquisition mode, selecting, as mass spectral fragments, the indole (m/z 144), the carbonylnaphthalenyl (m/z 155) and the naphthalenyl (m/z 127) moieties. Once developed and optimized, the analytical procedure was validated in term of sensitivity (lower limits of detection in the range of 0.1-0.5 ng mL(-1)), specificity (no interference was detected at the retention times of the analytes under investigation), recovery (higher than 65% with a satisfactory repeatability: CV% lower than 10), matrix effect (lower than 30% for all the biological specimens tested), repeatability of the retention times (CV% lower than 0.1), robustness, and carry over (the positive

  8. Antibiofilm activity of cashew juice pulp against Staphylococcus aureus, high performance liquid chromatography/diode array detection and gas chromatography-mass spectrometry analyses, and interference on antimicrobial drugs

    Directory of Open Access Journals (Sweden)

    Marcus V. Dias-Souza

    2017-07-01

    Full Text Available The epidemiology of Staphylococcus aureus infections has evolved in recent years, as this species is a major Gram-positive pathogen associated with healthcare services. The antimicrobial resistance of this species raises an urgent need for new treatment strategies. Fruits play important nutritional and economic roles in society, but their biological and pharmacological features are poorly explored when compared to nonedible parts of plants such as barks and leaves. In this study, we show that the cashew apple juice [cashew juice pulp (CJP] extract is active against the planktonic cells of S. aureus strains, and for the first time, we show that CJP is also active against S. aureus biofilms. High performance liquid chromatography and gas chromatography-mass spectrometry analyses were conducted to prospect for polyphenols and free carbohydrates, respectively. Cashew apple juice, which is rich in nutrients, is widely consumed in Brazil; therefore, the quality attributes of CJPs were investigated. Samples were evaluated for pH, total titratable acidity, vitamin C levels, and total soluble solids. We also detected an antagonistic interference of CJP when it was combined with different antimicrobial drugs.

  9. Application of ultraperformance liquid chromatography/mass spectrometry-based metabonomic techniques to analyze the joint toxic action of long-term low-level exposure to a mixture of organophosphate pesticides on rat urine profile.

    Science.gov (United States)

    Du, Longfei; Wang, Hong; Xu, Wei; Zeng, Yan; Hou, Yurong; Zhang, Yuqiu; Zhao, Xiujuan; Sun, Changhao

    2013-07-01

    In previously published articles, we evaluated the toxicity of four organophosphate (OP) pesticides (dichlorvos, dimethoate, acephate, and phorate) to rats using metabonomic technology at their corresponding no observed adverse effect level (NOAEL). Results show that a single pesticide elicits no toxic response. This study aimed to determine whether chronic exposure to a mixture of the above four pesticides (at their corresponding NOAEL) can lead to joint toxic action in rats using the same technology. Pesticides were administered daily to rats through drinking water for 24 weeks. The above mixture of the four pesticides showed joint toxic action at the NOAEL of each pesticide. The metabonomic profiles of rats urine were analyzed by ultraperformance liquid chromatography/mass spectrometry. The 16 metabolites statistically significantly changed in all treated groups compared with the control group. Dimethylphosphate and dimethyldithiophosphate exclusively detected in all treated groups can be used as early, sensitive biomarkers for exposure to a mixture of the OP pesticides. Moreover, exposure to the OP pesticides resulted in increased 7-methylguanine, ribothymidine, cholic acid, 4-pyridoxic acid, kynurenine, and indoxyl sulfate levels, as well as decreased hippuric acid, creatinine, uric acid, gentisic acid, C18-dihydrosphingosine, phytosphingosine, suberic acid, and citric acid. The results indicated that a mixture of OP pesticides induced DNA damage and oxidative stress, disturbed the metabolism of lipids, and interfered with the tricarboxylic acid cycle. Ensuring food safety requires not only the toxicology test data of each pesticide for the calculation of the acceptable daily intake but also the joint toxic action.

  10. Removal of BrO₃⁻ from drinking water samples using newly developed agricultural waste-based activated carbon and its determination by ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Naushad, Mu; Khan, Mohammad R; ALOthman, Zeid A; AlSohaimi, Ibrahim; Rodriguez-Reinoso, Francisco; Turki, Turki M; Ali, Rahmat

    2015-10-01

    Activated carbon was prepared from date pits via chemical activation with H3PO4. The effects of activating agent concentration and activation temperature on the yield and surface area were studied. The optimal activated carbon was prepared at 450 °C using 55 % H3PO4. The prepared activated carbon was characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric-differential thermal analysis, and Brunauer, Emmett, and Teller (BET) surface area. The prepared date pit-based activated carbon (DAC) was used for the removal of bromate (BrO3 (-)). The concentration of BrO3 (-) was determined by ultra-performance liquid chromatography-mass tandem spectrometry (UPLC-MS/MS). The experimental equilibrium data for BrO3 (-) adsorption onto DAC was well fitted to the Langmuir isotherm model and showed maximum monolayer adsorption capacity of 25.64 mg g(-1). The adsorption kinetics of BrO3 (-) adsorption was very well represented by the pseudo-first-order equation. The analytical application of DAC for the analysis of real water samples was studied with very promising results.

  11. Pressurized liquid extraction-gas chromatography-mass spectrometry for confirming the photo-induced generation of dioxin-like derivatives and other cosmetic preservative photoproducts on artificial skin.

    Science.gov (United States)

    Alvarez-Rivera, Gerardo; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2016-04-01

    The stability and photochemical transformations of cosmetic preservatives in topical applications exposed to UV-light is a serious but poorly understood problem. In this study, a high throughput extraction and selective method based on pressurized liquid extraction (PLE) coupled to gas chromatography-mass spectrometry (GC-MS) was validated and applied to investigate the photochemical transformation of the antioxidant butylated hydroxytoluene (BHT), as well as the antimicrobials triclosan (TCS) and phenyl benzoate (PhBz) in an artificial skin model. Two sets of photodegradation experiments were performed: (i) UV-Irradiation (8W, 254nm) of artificial skin directly spiked with the target preservatives, and (ii) UV-irradiation of artificial skin after the application of a cosmetic cream fortified with the target compounds. After irradiation, PLE was used to isolate the target preservatives and their transformation products. The follow-up of the photodegradation kinetics of the parent preservatives, the identification of the arising by-products, and the monitorization of their kinetic profiles was performed by GC-MS. The photochemical transformation of triclosan into 2,8-dichloro-dibenzo-p-dioxin (2,8-DCDD) and other dioxin-like photoproducts has been confirmed in this work. Furthermore, seven BHT photoproducts, and three benzophenones as PhBz by-products, have been also identified. These findings reveal the first evidences of cosmetic ingredients phototransformation into unwanted photoproducts on an artificial skin model. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Tissue-specific metabolite profiling of Cyperus rotundus L. rhizomes and (+)-nootkatone quantitation by laser microdissection, ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry, and gas chromatography-mass spectrometry techniques.

    Science.gov (United States)

    Jaiswal, Yogini; Liang, Zhitao; Guo, Ping; Ho, Hing-Man; Chen, Hubiao; Zhao, Zhongzhen

    2014-07-23

    Cyperus rotundus L. is a plant species commonly found in both India and China. The caused destruction of this plant is of critical concern for agricultural produce. Nevertheless, it can serve as a potential source of the commercially important sesquiterpenoid (+)-nootkatone. The present work describes comparative metabolite profiling and (+)-nootkatone content determination in rhizome samples collected from these two countries. Laser dissected tissues, namely, the cortex, hypodermal fiber bundles, endodermis, amphivasal vascular bundles, and whole rhizomes were analyzed by ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Gas chromatography-mass spectrometry (GC-MS) analysis was used for profiling of essential oil constituents and quantitation of (+)-nootkatone. The content of (+)-nootkatone was found to be higher in samples from India (30.47 μg/10 g) compared to samples from China (21.72 μg/10 g). The method was validated as per International Conference on Harmonisation (ICH) guidelines (Q2 R1). The results from this study can be applied for quality control and efficient utilization of this terpenoid-rich plant for several applications in food-based industries.

  13. A new liquid chromatography-mass spectrometry-based method to quantitate exogenous recombinant transferrin in cerebrospinal fluid: a potential approach for pharmacokinetic studies of transferrin-based therapeutics in the central nervous systems.

    Science.gov (United States)

    Wang, Shunhai; Bobst, Cedric E; Kaltashov, Igor A

    2015-01-01

    Transferrin (Tf) is an 80 kDa iron-binding protein that is viewed as a promising drug carrier to target the central nervous system as a result of its ability to penetrate the blood-brain barrier. Among the many challenges during the development of Tf-based therapeutics, the sensitive and accurate quantitation of the administered Tf in cerebrospinal fluid (CSF) remains particularly difficult because of the presence of abundant endogenous Tf. Herein, we describe the development of a new liquid chromatography-mass spectrometry-based method for the sensitive and accurate quantitation of exogenous recombinant human Tf in rat CSF. By taking advantage of a His-tag present in recombinant Tf and applying Ni affinity purification, the exogenous human serum Tf can be greatly enriched from rat CSF, despite the presence of the abundant endogenous protein. Additionally, we applied a newly developed (18)O-labeling technique that can generate internal standards at the protein level, which greatly improved the accuracy and robustness of quantitation. The developed method was investigated for linearity, accuracy, precision, and lower limit of quantitation, all of which met the commonly accepted criteria for bioanalytical method validation.

  14. Interlaboratory Trial for Measurement of Vitamin D and 25-Hydroxyvitamin D [25(OH)D] in Foods and a Dietary Supplement Using Liquid Chromatography-Mass Spectrometry

    DEFF Research Database (Denmark)

    Roseland, Janet Maxwell; Patterson, Kristine Y; Andrews, Karen W

    2016-01-01

    performance has been needed. The primary goal of this study was to evaluate whether vitamin D3 and 25(OH)D3 concentrations in food and DS materials could be measured with acceptable reproducibility. Five experienced laboratories from the United States and other countries participated, all using liquid......Assessment of total vitamin D intake from foods and dietary supplements (DSs) may be incomplete if 25-hydroxyvitamin D [25(OH)D] intake is not included. However, 25(OH)D data for such intake assessments are lacking, no food or DS reference materials (RMs) are available, and comparison of laboratory...... chromatography tandem-mass spectrometry but no common analytical protocol; however, various methods were used for determining vitamin D3 in the DS. Five animal-based materials (including three commercially available RMs) and one DS were analyzed. Reproducibility results for the materials were acceptable. Thus...

  15. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    Science.gov (United States)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  16. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    Science.gov (United States)

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  17. Screening and identification of antioxidants in biological samples using high-performance liquid chromatography-mass spectrometry and its application on Salacca edulis Reinw.

    Science.gov (United States)

    Shui, Guanghou; Leong, Lai Peng

    2005-02-23

    In this study, a new approach was developed for screening and identifying antioxidants in biological samples. The approach was based on significant decreases of the intensities of ion peaks obtained from high-performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) upon reaction with 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) free radicals. HPLC-MS/MS was further applied to elucidate structures of antioxidant peaks characterized in a spiking test. The new approach could also be used to monitor the reactivity of antioxidants in biological sample with free radicals. The approach was successfully applied to the identification of antioxidants in salak (Salacca edulis Reinw), a tropical fruit that is reported to be a very good source of natural antioxidants, but it was still not clear which compounds were responsible for its antioxidant property. The antioxidants in salak were identified to be chlorogenic acid, (-)-epicatechin, and singly linked proanthocyanidins that mainly existed as dimers through hexamers of catechin or epicatechin. In salak, chlorogenic acid was identified to be an antioxidant of the slow reaction type as it reacted with free radicals much more slowly than either (-)-epicatechin or proanthocyanidins. The new approach was proved to be useful for the characterization and identification of antioxidants in biological samples as a mass detector combined with an HPLC separation system not only serves as an ideal tool to monitor free radical active components but also provides their possible chemical structures in a biological sample.

  18. Sensitive method for the quantitative determination of proguanil and its metabolites in rat blood and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Leveque, Nathalie L; Charman, William N; Chiu, Francis C K

    2006-01-18

    A sensitive, simple and fast liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 1-(4-chlorophenyl)biguanide (4CPB), was developed and validated over a concentration range of 1-2000 ng/mL using only 50 microL of blood or plasma. After a simple solvent precipitation procedure, the supernatant was analysed directly by HPLC-MS/MS. Separation was achieved using an ethyl-linked phenyl reverse phase column with polar endcapping with an acetonitrile-water-formic acid gradient. Mass spectrometry was performed using a triple quadrupole mass spectrometer operating in positive electrospray ionization mode. The elution of PG (254.07-->169.99), CG (252.12-->195.02) and 4CPB (212.06-->153.06) was monitored using selected reaction monitoring. The three compounds and the internal standard (chloroproguanil) were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in blood and plasma. The limit of quantification of PG and CG was 1 ng/mL and 5 ng/mL for 4CPB in rat blood and plasma. The extraction efficiency of PG, CG and 4CPB from rat blood and plasma was higher than 73%. The intra- and inter-assay variability of PG, CG and 4CPB were within 12% and the accuracy within +/-5%. This new assay offers higher sensitivity and a much shorter run time over earlier methods.

  19. [Rapid screening and confirmation of 205 pesticide residues in rice by QuEChERS and liquid chromatography-mass spectrometry].

    Science.gov (United States)

    Chen, Xi; Cheng, Lei; Qu, Shichao; Huang, Daliang; Liu, Jiacheng; Cui, Han; Jia, Yanbo; Ji, Mingshan

    2015-10-01

    A method for rapid screening and confirmation of 205 pesticide residues in rice was developed by combining QuEChERS and high performance liquid chromatography-triple quadrupole-linear ion trap mass spectrometry (LC-Q-TRAP/MS). The rice samples were extracted with acetonitrile, and then cleaned up with primary secondary amine (PSA), anhydrous magnesium sulfate (MgSO4) and C18 adsorbent. Finally, the samples were detected by LC-Q-TRAP/MS in multiple reaction monitoring with information-dependent acquisition of enhanced product ion (MRM-IDA-EPI) mode followed with database searching. A total of 205 pesticide residues were confirmed by retention times, ion pairs and the database searching using EPI library, and quantified by external standard method. All the pesticides showed good linearities with linear correlation coefficients all above 0.995. The limits of quantification (LOQs) for the 205 pesticides were 0.5-10.0 μg/kg. The average recoveries of the 205 pesticides ranged from 62.4% to 127.1% with the relative standard deviations (RSDs) of 1.0% - 20.0% at spiked levels of 10 μg/kg and 50 μg/kg, and only 20 min were needed for the analysis of an actual rice sample. In brief, the method is fast, accurate and highly sensitive, and is suitable for the screening and confirmation of pesticide residues in rice.

  20. The detection and quantitative analysis of the psychoactive component of Salvia divinorum, salvinorin A, in human biological fluids using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    McDonough, Pamela C; Holler, Justin M; Vorce, Shawn P; Bosy, Thomas Z; Magluilo, Joseph; Past, Marilyn R

    2008-01-01

    Salvia divinorum, a member of the mint plant family, has hallucinogenic properties that have become increasingly sought after by recreational drug users. The main psychoactive component, salvinorin A, has potency comparable to lysergic acid diethylamide. Though still legal to possess in most of the United States and much of Europe, little is known regarding the compound's long-term health effects, addiction liability, and pharmacokinetics. Limited data are available in the scientific literature, and few analytical methods are published for the detection in human biological fluids. These factors contribute to the unfamiliarity of the compound and complicate the method development process necessary to accommodate special requested testing for salvinorin A. A sensitive analytical method for the detection and quantitation of salvinorin A in human biological fluids was developed and validated to resolve analytical shortcomings. The method utilizes a solid-phase extraction technique coupled with liquid chromatography-electrospray ionization mass spectrometry operated in selected ion monitoring mode. The assay has a linear range of 5.0-100 ng/mL with a correlation coefficient of 0.997. The limit of detection and limit of quantitation were experimentally determined as 2.5 and 5.0 ng/mL, respectively. The method has been applied to blood and urine samples successfully and can be used to detect the presence of salvinorin A in forensic testing.

  1. Simultaneous determination of praziquantel, pyrantel embonate, febantel and its active metabolites, oxfendazole and fenbendazole, in dog plasma by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Klausz, Gabriella; Keller, Éva; Sára, Zoltán; Székely-Körmöczy, Péter; Laczay, Péter; Ary, Kornélia; Sótonyi, Péter; Róna, Kálmán

    2015-12-01

    A liquid chromatography-electrospray-mass spectrometry method (LC/MS) has been developed and validated for determination of praziquantel (PZQ), pyrantel (PYR), febantel (FBT), and the active metabolites fenbendazole (FEN) and oxfendazole (OXF), in dog plasma, using mebendazole as internal standard (IS). The method consists of solid-phase extractions on Strata-X polymeric cartridges. Chromatographic separation was carried out on a Phenomenex Gemini C6 -Phenyl column using binary gradient elution containing methanol and 50 mm ammonium-formate (pH 3). The method was linear (r(2)  ≥ 0.990) over concentration ranges of 3-250 ng/mL for PYR andFEB, 5-250 ng/mL for OXF and FEN, and 24-1000 ng/mL for PZQ. The mean precisions were 1.3-10.6% (within-run) and 2.5-9.1% (between-run), and mean accuracies were 90.7-109.4% (within-run) and 91.6-108.2% (between-run). The relative standard deviations (RSD) were <9.1%. The mean recoveries of five targeted compounds from dog plasma ranged from 77 to 94%.The new LC/MS method described herein was fully validated and successfully applied to the bioequivalence studies of different anthelmintic formulations such as tablets containing PZQ, PYR embonate and FBT in dogs after oral administration. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Application of solid phase microextraction followed by liquid chromatography-mass spectrometry in the determination of antibiotic drugs and their metabolites in human whole blood and tissue samples.

    Science.gov (United States)

    Szultka-Mlynska, Malgorzata; Pomastowski, Pawel; Buszewski, Boguslaw

    2018-06-01

    A sensitive, rapid and specific analytical method using high performance liquid chromatography coupled with mass spectrometry (HPLC-QqQ-MS) was developed to determine selected antibiotic drugs and their metabolites (amoxicillin, cefotaxime, ciprofloxacin, clindamycin and metronidazole; amoxycilloic acid, 4-hydroxyphenyl glycyl amoxicillin, desacetyl cefotaxime, 3-desacetyl cefotaxime lactone, ciprofloxacin N-oxide, N-demethylclindamycin, clindamycin sulfoxide, and hydroxy metronidazole) in human whole blood and vascularized tissue after single oral administration. The samples were prepared by solid phase microextraction with C18 fibers (SPME C18 ) and determined on a GRACE analytical C18 column, Vision HT (50 × 2 mm, 1.5 μm) at the flow rate of 0.4 mL min -1 using water and acetonitrile (containing 0.1% formic acid) as the mobile phase. The proposed method was successfully applied in a pharmacokinetic study of the selected antibiotic drugs and their metabolites in real human samples. Additionally, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS) was used for identification and qualification analysis of the target compounds. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Addressing the need for biomarker liquid chromatography/mass spectrometry assays: a protocol for effective method development for the bioanalysis of endogenous compounds in cerebrospinal fluid.

    Science.gov (United States)

    Benitex, Yulia; McNaney, Colleen A; Luchetti, David; Schaeffer, Eric; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M

    2013-08-30

    Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Differentiation between lutein monoester regioisomers and detection of lutein diesters from marigold flowers (Tagetes erecta L.) and several fruits by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Breithaupt, Dietmar E; Wirt, Ursula; Bamedi, Ameneh

    2002-01-02

    Liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCIMS) was employed for the identification of eight lutein monoesters, formed by incomplete enzymatic saponification of lutein diesters of marigold (Tagetes erecta L.) by Candida rugosa lipase. Additionally, the main lutein diesters naturally occurring in marigold oleoresin were chromatographically separated and identified. The LC-MS method allows for characterization of lutein diesters occurring as minor components in several fruits; this was demonstrated by analysis of extracts of cape gooseberry (Physalis peruviana L.), kiwano (Cucumis metuliferus E. Mey. ex Naud.), and pumpkin (Cucurbita pepo L.). The assignment of the regioisomers of lutein monoesters is based on the characteristic fragmentation pattern: the most intense daughter ion generally results from the loss of the substituent (fatty acid or hydroxyl group) bound to the epsilon-ionone ring, yielding an allylic cation. The limit of detection was estimated at 0.5 microg/mL with lutein dimyristate as reference compound. This method provides a useful tool to obtain further insight into the biochemical reactions leading to lutein ester formation in plants.

  5. Sensitive Determination of Onco-metabolites of D- and L-2-hydroxyglutarate Enantiomers by Chiral Derivatization Combined with Liquid Chromatography/Mass Spectrometry Analysis

    Science.gov (United States)

    Cheng, Qing-Yun; Xiong, Jun; Huang, Wei; Ma, Qin; Ci, Weimin; Feng, Yu-Qi; Yuan, Bi-Feng

    2015-01-01

    2-hydroxyglutarate (2HG) is a potent competitor of α-ketoglutarate (α-KG) and can inhibit multiple α-KG dependent dioxygenases that function on the epigenetic modifications. The accumulation of 2HG contributes to elevated risk of malignant tumors. 2HG carries an asymmetric carbon atom in its carbon backbone and differentiation between D-2-hydroxyglutarate (D-2HG) and L-2-hydroxyglutarate (L-2HG) is crucially important for accurate diagnosis of 2HG related diseases. Here we developed a strategy by chiral derivatization combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis for highly sensitive determination of D-2HG and L-2HG enantiomers. N-(p-toluenesulfonyl)-L-phenylalanyl chloride (TSPC) was used to derivatize 2HG. The formed diastereomers by TSPC labeling can efficiently improve the chromatographic separation of D-2HG and L-2HG. And derivatization by TSPC could also markedly increase the detection sensitivities by 291 and 346 folds for D-2HG and L-2HG, respectively. Using the developed method, we measured the contents of D-2HG and L-2HG in clear cell renal cell carcinoma (ccRCC) tissues. We observed 12.9 and 29.8 folds increase of D-2HG and L-2HG, respectively, in human ccRCC tissues compared to adjacent normal tissues. The developed chiral derivatization combined with LC-ESI-MS/MS analysis offers sensitive determination of D-2HG and L-2HG enantiomers, which benefits the precise diagnosis of 2HG related metabolic diseases. PMID:26458332

  6. Dried Blood Spots Combined With Ultra-High-Performance Liquid Chromatography-Mass Spectrometry for the Quantification of the Antipsychotics Risperidone, Aripiprazole, Pipamperone, and Their Major Metabolites.

    Science.gov (United States)

    Tron, Camille; Kloosterboer, Sanne M; van der Nagel, Bart C H; Wijma, Rixt A; Dierckx, Bram; Dieleman, Gwen C; van Gelder, Teun; Koch, Birgit C P

    2017-08-01

    Risperidone, aripiprazole, and pipamperone are antipsychotic drugs frequently prescribed for the treatment of comorbid behavioral problems in children with autism spectrum disorders. Therapeutic drug monitoring (TDM) could be useful to decrease side effects and to improve patient outcome. Dried blood spot (DBS) sample collection seems to be an attractive technique to develop TDM of these drugs in a pediatric population. The aim of this work was to develop and validate a DBS assay suitable for TDM and home sampling. Risperidone, 9-OH risperidone, aripiprazole, dehydroaripiprazole, and pipamperone were extracted from DBS and analyzed by ultra-high-performance liquid chromatography-tandem mass spectrometry using a C18 reversed-phase column with a mobile phase consisting of ammonium acetate/formic acid in water or methanol. The suitability of DBS for TDM was assessed by studying the influence of specific parameters: extraction solution, EDTA carryover, hematocrit, punching location, spot volume, and hemolysis. The assay was validated with respect to conventional guidelines for bioanalytical methods. The method was linear, specific without any critical matrix effect, and with a mean recovery around 90%. Accuracy and imprecision were within the acceptance criteria in samples with hematocrit values from 30% to 45%. EDTA or hemolysis did not skew the results, and no punching carryover was observed. No significant influence of the spot volume or the punch location was observed. The antipsychotics were all stable in DBS stored 10 days at room temperature and 1 month at 4 or -80°C. The method was successfully applied to quantify the 3 antipsychotics and their metabolites in patient samples. A UHPLC-MS/MS method has been successfully validated for the simultaneous quantification of risperidone, 9-OH risperidone, aripiprazole, dehydroaripiprazole, and pipamperone in DBS. The assay provided good analytical performances for TDM and clinical research applications.

  7. Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Burkhardt, M.R.; Gates, Paul M.; Werner, S.L.; Battaglin, W.A.

    2000-01-01

    Sulfonylurea (SU), imidazolinone (IMI), and sulfonamide (SA) herbicides are new classes of low-application-rate herbicides increasingly used by farmers. Some of these herbicides affect both weed and crop species at low dosages and must be carefully used. Less is known about the effect of these compounds on non-crop plant species, but a concentration of 100 ng/l in water has been proposed as the threshold for possible plant toxicity for most of these herbicides. Hence, analytical methods must be capable of detecting SUs, IMIs, and SAs at concentrations less than 100 ng/l in ambient water samples. The authors developed a two-cartridge, solid-phase extraction method for isolating 12 SU, 3 IMI, and 1 SA herbicides by using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS) to identify and quantify these herbicides to 10 ng/l. This method was used to analyze 196 surface- and ground-water samples collected from May to August 1998 throughout the Midwestern United States, and more than 100 quality-assurance and quality-control samples. During the 16 weeks of the study, the HPLC/ESI-MS maintained excellent calibration linearity across the calibration range from 5 to 500 ng/l, with correlation coefficients of 0.9975 or greater. Continuing calibration verification standards at 100-ng/l concentration were analyzed throughout the study, and the average measured concentrations for individual herbicides ranged from 93 to 100 ng/l. Recovery of herbicides from 27 reagent-water samples spiked at 50 and 100 ng/l ranged from 39 to 92%, and averaged 73%. The standard deviation of recoveries ranged from 14 to 26%, and averaged 20%. This variability reflects multiple instruments, operators, and the use of automated and manual sample preparation. Spiked environmental water samples had similar recoveries, although for some herbicides, the sample matrix enhanced recoveries by as much as 200% greater than the spiked concentration. This matrix

  8. Development of an isotope labeling ultra-high performance liquid chromatography mass spectrometric method for quantification of acylglycines in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Stanislaus, Avalyn; Guo, Kevin [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Li Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2012-10-31

    Graphical abstract: - Abstract: Acylglycines play a crucial regulatory and detoxification role in the accumulation of the corresponding acyl CoA esters and are an important class of metabolites in the diagnoses of inborn errors of metabolism. Sensitive quantification of a large number of acylglycines not only improves diagnosis but also enables the discovery of potential new biomarkers of diseases. We report an ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS) method for quantifying acylglycines in human urine with high sensitivity. This method is based on the use of a newly developed isotope labeling reagent, p-dimethylaminophenacyl (DmPA) bromide, to label acylglycines to improve detection sensitivity. Eighteen acylglycines, namely acetylglycine, propionylglycine, isobutyrylglycine, butyrylglycine, 4-hydroxyphenylacetylglycine, 2-furoylglycine, tiglylglycine, 2-methybutyrylglycine, 3-methylcrotonylglycine, isovalerylglycine, valerylglycine, hexanoylglycine, phenylacetylglycine, phenylpropionylglycine, glutarylglycine, heptanoylglycine, octanoylglycine and suberylglycine, were measured. This method uses calibration standards prepared in surrogate matrix (un-derivatized urine) and stable-isotope labeled analytes as the internal standards. The analysis was carried out in the positive ion detection mode using multiple reaction monitoring (MRM) survey scans. The calibration curves were validated over the range of 1.0-500 nM. The method achieved a lower limit of quantitation (LLOQ) of 1-5 nM for all analytes, as measured by the standard derivations associated with calibration curves and confirmed in surrogate matrix; the signal-to-noise ratio at LLOQ ranged from 12.50 to 156.70. Both accuracy (% RE or relative error) and precision (% CV) were <15%. Matrix effects were minimized using the surrogate matrix. All eighteen analytes were stable in urine for at least 5 h at room temperature, autosampler (4 Degree-Sign C) for 24 h, 7 weeks at -20

  9. Toxicity and Detoxification Effects of Herbal Caowu via Ultra Performance Liquid Chromatography/Mass Spectrometry Metabolomics Analyzed using Pattern Recognition Method

    Science.gov (United States)

    Yan, Yan; Zhang, Aihua; Dong, Hui; Yan, Guangli; Sun, Hui; Wu, Xiuhong; Han, Ying; Wang, Xijun

    2017-01-01

    were identified and validated as phenotypic toxicity biomarkers of CaowuMetabolite changes of toxicity obtained can be adjusted by different combinatorial interventions.Pattern recognition plot reflects the toxicity effects tendency of the urine metabolic fluctuations according to time after treatment of herbal Caowu. Abbreviations used: CW: Caowu (Radix Aconiti kusnezoffii); CHW: Chuanwu (Radix Aconiti); TCM: Traditional Chinese Medicine; CG: Caowu and Gancao; CB: Caowu and Baishao; CR: Caowu and Renshen; QC: Quality control; UPLC: Ultra performance liquid chromatography; MS: Mass spectrometry; PCA: Principal component analysis; PLS-DA: Partial least squares-discriminant analysis; OPLS: Orthogonal projection to latent structures analysis. PMID:29200734

  10. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    Science.gov (United States)

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  11. Effect of Mg2+ and Fe2+ Concentrations in Culture Medium on CGF Formation from Microalgae Chlorella Pyrenoidosa Ink and Analysis of Amino Acids by Liquid Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kusmiati Kusmiati

    2015-06-01

    Full Text Available Chlorella pyrenoidosa (C. pyrenoidosa contains Chlorella Growth Factor (CGF, which consists of proteins and polysaccharides. CGF is located inside the nucleus of cells and is beneficial to humans as a food supplement, an immunity booster, and an antioxidant. CGF formation of C. pyrenoidosa is influenced by medium composition. C. pyrenoidosa INK was cultured in a modified basal medium (MBM with various concentrations of Mg2+ (0.5, 1.0, and 1.5 g/L and Fe2+ (3.5×10-4 and 5.0×10-4 g/L. The experiments were performed and analyzed under a completely randomized design using a 2-L bottle with three replications. The results showed that MBM with 1.0 g/L of Mg2+ and 3.5×10-4 g/L of Fe2+ yielded the optimal growth curve for C. pyrenoidosa. Analysis of protein content was carried out using the Lowry method with a spectrophotometer at λ=750 nm, and the obtained results were 0.0974 mg/mL (extract and 6.4097 mg/ml (supernatant. Furthermore, analysis of glucose content was carried out using the phenol sulfate method (λ = 490 nm, and the obtained results were 49.331 ppm (extract and 1566.911 ppm (supernatant. Analysis of amino acids in CGF using liquid chromatography-mass spectrometry (LC-MS indicated the presence of tyrosine, proline, glutamate, alanine, valine, tryptopan, phenylalanine, methionine, and leucine-isoleucine.

  12. A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices.

    Science.gov (United States)

    Zhu, Peijuan; Ding, Wei; Tong, Wei; Ghosal, Anima; Alton, Kevin; Chowdhury, Swapan

    2009-06-01

    A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) is implemented using the statistical programming language R to remove non-drug-related ion signals from accurate mass liquid chromatography/mass spectrometry (LC/MS) data. The background-subtraction part of the algorithm is similar to a previously published procedure (Zhang H and Yang Y. J. Mass Spectrom. 2008, 43: 1181-1190). The noise reduction algorithm (NoRA) is an add-on feature to help further clean up the residual matrix ion noises after background subtraction. It functions by removing ion signals that are not consistent across many adjacent scans. The effectiveness of BgS-NoRA was examined in biological matrices by spiking blank plasma extract, bile and urine with diclofenac and ibuprofen that have been pre-metabolized by microsomal incubation. Efficient removal of background ions permitted the detection of drug-related ions in in vivo samples (plasma, bile, urine and feces) obtained from rats orally dosed with (14)C-loratadine with minimal interference. Results from these experiments demonstrate that BgS-NoRA is more effective in removing analyte-unrelated ions than background subtraction alone. NoRA is shown to be particularly effective in the early retention region for urine samples and middle retention region for bile samples, where the matrix ion signals still dominate the total ion chromatograms (TICs) after background subtraction. In most cases, the TICs after BgS-NoRA are in excellent qualitative correlation to the radiochromatograms. BgS-NoRA will be a very useful tool in metabolite detection and identification work, especially in first-in-human (FIH) studies and multiple dose toxicology studies where non-radio-labeled drugs are administered. Data from these types of studies are critical to meet the latest FDA guidance on Metabolite in Safety Testing (MIST). Copyright (c) 2009 John Wiley & Sons, Ltd.

  13. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    International Nuclear Information System (INIS)

    Koivunen, Marja E.; Dettmer, Katja; Vermeulen, Roel; Bakke, Berit; Gee, Shirley J.; Hammock, Bruce D.

    2006-01-01

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL -1 ), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL -1 ) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R 2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R 2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine

  14. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  15. Method for the fast determination of bromate, nitrate and nitrite by ultra performance liquid chromatography-mass spectrometry and their monitoring in Saudi Arabian drinking water with chemometric data treatment.

    Science.gov (United States)

    Khan, Mohammad Rizwan; Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Busquets, Rosa; Naushad, Mu

    2016-05-15

    A rapid, sensitive and precise method for the determination of bromate (BrO3(-)), nitrate (NO3(-)) and nitrite (NO2(-)) in drinking water was developed with Ultra performance Liquid Chromatography-Mass Spectrometry (UPLC-ESI/MS). The elution of BrO3(-), NO3(-) and NO2(-) was attained in less than two minutes in a reverse phase column. Quality parameters of the method were established; run-to-run and day-to-day precisions were water from Saudi Arabia (Jeddah, Dammam and Riyadh areas) and commercial bottled water (from well or unknown source) after mere filtration steps. The quantified levels of NO3(-) were not found to pose a risk. In contrast, BrO3(-) was found above the maximum contaminant level established by the US Environmental Protection Agency in 25% and 33% of the bottled and metropolitan waters, respectively. NO2(-) was found at higher concentrations than the aforementioned limits in 70% and 92% of the bottled and metropolitan water samples, respectively. Therefore, remediation measures or improvements in the disinfection treatments are required. The concentrations of BrO3(-), NO3(-) and NO2(-) were mapped with Principal Component analysis (PCA), which differentiated metropolitan water from bottled water through the concentrations of BrO3(-) and NO3(-) mainly. Furthermore, it was possible to discriminate between well water; blend of well water and desalinated water; and desalinated water. The point or source (region) was found to not be distinctive. Copyright © 2016. Published by Elsevier B.V.

  16. Comparative gas chromatography-mass spectroscopy, Fourier transform infrared spectroscopy, and high-performance liquid chromatography analysis of essential oils extracted using 4 methods from the leaves of Eucalyptus globulus L.

    Directory of Open Access Journals (Sweden)

    Yasmeen Khan

    2016-01-01

    Full Text Available Background: Eucalyptus globulus L. (family, Myrtaceae is one of the world′s most widely planted genera. E. globulus L., commonly referred to as Tasmanian blue gum, is a fast growing, evergreen tree, native to Tasmania and South-East Australia. Apart from its extensive use in pulp industry, it is also produces Oleum Eucalypti (eucalyptus oil that is extracted on commercial scale in many countries such as China, India, South Africa, Portugal, Brazil, and Tasmania, as a raw material in perfumery, cosmetics, food beverage, aromatherapy, and phytotherapy. Materials and Methods: Traditional hydrodistillation (HD, solvent extraction (SE, ultrasonication (US, and supercritical fluid extraction (SFE were conducted for the extraction of essential oil from the leaves of E. globulus. Each oil was evaluated in terms of high-performance liquid chromatography (HPTLC and Fourier transform infrared spectroscopy (FTIR fingerprinting with qualitative and semi-quantitative composition of the isolated essential oil by gas chromatography-mass spectroscopy (GCMS, the extract yield of essential oil was 2.60%, 2.2%, 2.0%, and 3.6% v/w, respectively, for HD, SE, US, and SFE. Results: A total of 53 compounds were identified by GCMS. Comparative analysis indicated that SFE was favorable for extraction of monoterpene hydrocarbon, sesquiterpene hydrocarbon, and oxygenated sesquiterpene hydrocarbon. HD, SE, and US had certain advantages in the extraction of aliphatic saturated hydrocarbons organic acid and esters. Overlay, FTIR spectra of oil samples obtained by four extraction methods were superimposed with each other showing similar components. The maximum separation of compound seen at 254 nm and lesser at 366 nm by HPTLC fingerprinting which again showed superimposed chromatograms. Conclusion: It is concluded that different extraction method may lead to different yields of essential oils where the choice of appropriate method is very important to obtained more desired

  17. Optimization of a two-dimensional liquid chromatography-supercritical fluid chromatography-mass spectrometry (2D-LC-SFS-MS) system to assess "in-vivo" inter-conversion of chiral drug molecules.

    Science.gov (United States)

    Goel, Meenakshi; Larson, Eli; Venkatramani, C J; Al-Sayah, Mohammad A

    2018-05-01

    Enantioselective analysis is an essential requirement during the pharmaceutical development of chiral drug molecules. In pre-clinical and clinical studies, the Food and Drug Administration (FDA) mandates the assessment of "in vivo" inter-conversion of chiral drugs to determine their physiological effects. In-vivo analysis of the active pharmaceutical ingredient (API) and its potential metabolites could be quite challenging due to their low abundance (ng/mL levels) and matrix interferences. Therefore, highly selective and sensitive analytical techniques are required to separate the API and its metabolites from the matrix components and one another. Additionally, for chiral APIs, further analytical separation is required to resolve the API and its potential metabolites from their corresponding enantiomers. In this work, we demonstrate the optimization of our previously designed two-dimensional liquid chromatography-supercritical fluid chromatography-mass spectrometry (2D-LC-SFC -MS) system to achieve 10 ng/mL detection limit [1]. The first LC dimension, used as a desalting step, could efficiently separate the API from its potential metabolites and matrix components. The API and its metabolites were then trapped/focused on small trapping columns and transferred onto the second SFC dimension for chiral separation. Detection can be achieved by ultra-violet (UV) or MS detection. Different system parameters such as column dimensions, transfer volumes, trapping column stationary phase, system tubing internal diameter (i.d.), and detection techniques, were optimized to enhance the sensitivity of the 2D-LC-SFC-MS system. The limit of detection was determined to be 10 ng/mL. An application is described where a mouse hepatocyte treated sample was analyzed using the optimized 2D-LC-SFC-MS system with successful assessment of the ratio of API to its metabolite (1D-LC), as well as the corresponding enantiomeric excess values (% e.e.) of each (2D-SFC). Copyright © 2018

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by graphitized carbon-based solid-phase extraction and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Anderson, Bruce D.; Werner, Stephen L.; Soliven, Paul P.; Coffey, Laura J.; Burkhardt, Mark R.

    2001-01-01

    In 1996, the U.S. Geological Survey National Water Quality Laboratory (NWQL) developed and implemented a graphitized carbon-based solid-phase extraction and high-performance liquid chromatographic analytical method to determine polar pesticide concentrations in surface- and ground-water samples. Subsequently, the NWQL developed a complementary analysis that uses high-performance liquid chromatography/mass spectrometry to detect, identify, and quantify polar pesticides and pesticide metabolites in filtered water at concentrations as low as 10 nanograms per liter. This new method was designed to improve sensitivity and selectivity over the prior method, and to reduce known interferences from natural organic matter.In this new method, pesticides are extracted from filtered water samples by useing a 0.5-gram graphitized carbon-based solid-phase extraction cartridge, eluted from the cartridge, and concentrations determined by using high-performance liquid chromatography with electrospray ionization-mass spectrometry. The upper concentration limit is 1.000 microgram per liter (μg/L) for most compounds. Single-operator method detection limits in organic-free water samples fortified with pesticides at a concentration of 0.025 μg/L ranged from 0.0019 to 0.022 μg/L for all compounds in the method. The grand mean (mean of mean recoveries for individual compounds) recoveries in organic-free water samples ranged from 72 to 89 percent, fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Grand mean recoveries in ground- and surface-water samples ranged from 46 to 119 percent, also fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Long-term recoveries from reagent water spikes were used to demonstrate that 38 of 65 compounds can be reported without qualification of the quantitative result across the analytical range of the method. The remaining 27 are reported with qualified estimates of concentration because of greater

  19. Inflammatory Response and Barrier Dysfunction by Different e-Cigarette Flavoring Chemicals Identified by Gas Chromatography-Mass Spectrometry in e-Liquids and e-Vapors on Human Lung Epithelial Cells and Fibroblasts.

    Science.gov (United States)

    Gerloff, Janice; Sundar, Isaac K; Freter, Robert; Sekera, Emily R; Friedman, Alan E; Robinson, Risa; Pagano, Todd; Rahman, Irfan

    2017-03-01

    Recent studies suggest that electronic cigarette (e-cig) flavors can be harmful to lung tissue by imposing oxidative stress and inflammatory responses. The potential inflammatory response by lung epithelial cells and fibroblasts exposed to e-cig flavoring chemicals in addition to other risk-anticipated flavor enhancers inhaled by e-cig users is not known. The goal of this study was to evaluate the release of the proinflammatory cytokine (interleukin-8 [IL-8]) and epithelial barrier function in response to different e-cig flavoring chemicals identified in various e-cig e-liquid flavorings and vapors by chemical characterization using gas chromatography-mass spectrometry analysis. Flavorings, such as acetoin (butter), diacetyl, pentanedione, maltol (malt), ortho-vanillin (vanilla), coumarin, and cinnamaldehyde in comparison with tumor necrosis factor alpha (TNFα), were used in this study. Human bronchial epithelial cells (Beas2B), human mucoepidermoid carcinoma epithelial cells (H292), and human lung fibroblasts (HFL-1) were treated with each flavoring chemical for 24 hours. The cells and conditioned media were then collected and analyzed for toxicity (viability %), lung epithelial barrier function, and proinflammatory cytokine IL-8 release. Cell viability was not significantly affected by any of the flavoring chemicals tested at a concentration of 10 μM to 1 mM. Acetoin and diacetyl treatment induced IL-8 release in Beas2B cells. Acetoin- and pentanedione-treated HFL-1 cells produced a differential, but significant response for IL-8 release compared to controls and TNFα. Flavorings, such as ortho-vanillin and maltol, induced IL-8 release in Beas2B cells, but not in H292 cells. Of all the flavoring chemicals tested, acetoin and maltol were more potent inducers of IL-8 release than TNFα in Beas2B and HFL-1 cells. Flavoring chemicals rapidly impaired epithelial barrier function in human bronchial epithelial cells (16-HBE) as measured by electric cell surface

  20. Microextraction with polyethersulfone for bisphenol-A, alkylphenols and hormones determination in water samples by means of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Ros, O; Vallejo, A; Blanco-Zubiaguirre, L; Olivares, M; Delgado, A; Etxebarria, N; Prieto, A

    2015-03-01

    In the present work, the suitability of polyethersulfone (PES) tube was assessed for the simultaneous sorptive microextraction of commonly found endocrine disrupting compounds in natural waters such as bisphenol-A (BPA), nonylphenol technical mixture (NP mix), 4-tert-octylphenol (4tOP), 4-n-octylphenol (4-nOP), 17β-estradiol (E2) and 17α-ethynilestradiol (EE2). After the concentration of target compounds in the PES polymer, the analytes were recovered soaking the polymer with a suitable solvent (ethyl acetate or methanol), derivatized using N,O-bis(trimethylsilyl)trifluoroacetamide with 1% of trimethylchlorosilane (BSTFA+1% TMCS) and determined by gas chromatography-mass spectrometry (GC-MS). The analysis was also performed without derivatization step by means of liquid chromatography-tandem mass spectrometry (LC-MS/MS). Extraction parameters (addition of MeOH, ionic strength, extraction speed and time and desorption time) were evaluated and the optimum conditions were fixed as follows: 150 mL water samples containing a 10% (w/v) of sodium chloride and using 5 tubular PES sorbent fibers (1.5 cm length×0.7 mm o.d.). Equilibrium conditions were achieved after 9 h, with absolute extraction efficiencies ranging from 27 to 56%. On the whole, good apparent recoveries were achieved (68-103% and 81-122% for GC-MS and LC-MS/MS, respectively) using deuterated analogues as surrogates. Achieved quantification limits (LOQs) varied between 2-154 ng/L and 2-63 ng/L for all the compounds using GC-MS and LC-MS/MS, respectively. The effect of organic matter was evaluated previous to apply the final method to the analysis of estuarine and wastewater real samples. The comparison of both methods showed that overall, PES-LC-MS/MS provided shorter sample preparation time and better LODs, but PES-silylation-GC-MS allowed the simultaneous determination of all the studied compounds with adequate repeatability and accuracy. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A strategy for efficient discovery of new natural compounds by integrating orthogonal column chromatography and liquid chromatography/mass spectrometry analysis: Its application in Panax ginseng, Panax quinquefolium and Panax notoginseng to characterize 437 potential new ginsenosides.

    Science.gov (United States)

    Yang, Wen-zhi; Ye, Min; Qiao, Xue; Liu, Chun-fang; Miao, Wen-juan; Bo, Tao; Tao, Hai-yan; Guo, De-an

    2012-08-20

    To discover new natural compounds from herbal medicines tends to be more and more difficult. In this paper, a strategy integrating orthogonal column chromatography and liquid chromatography/mass spectrometry (LC/MS) analysis was proposed, and was applied for rapid discovery of new ginsenosides from Panax ginseng (PG), Panax quinquefolium (PQ), and Panax notoginseng (PN). The ginsenosides extracts were fractionated by MCI gel×silica gel orthogonal column chromatography. The fractions were then separated on a C(18) HPLC column, eluted with a three-component mobile phase (CH(3)CN/CH(3)OH/3mM CH(3)COONH(4)H(2)O), and detected by electrospray ionization tandem mass spectrometry. The structures of unknown ginsenosides were elucidated by analyzing negative and positive ion mass spectra, which provided complementary information on the sapogenins and oligosaccharide chains, respectively. A total of 623 comprising 437 potential new ginsenosides were characterized from the ethanol extracts of PG, PQ and PN. New acylations, diversified saccharide chains and C-17 side chains constituted novelty of the newly identified ginsenosides. An interpretation guideline was proposed for structural characterization of unknown ginsenosides by LC/MS. To confirm reliability of this strategy, two targeted unknown trace ginsenosides were obtained in pure form by LC/MS-guided isolation. Based on extensive NMR spectroscopic analysis and other techniques, they were identified as 3-O-[6-O-(E)-butenoyl-β-D-glucopyranosyl(1,2)-β-D-glucopyranosyl]-20(S)-protopanaxadiol-20-O-β-D-glucopyranosyl(1,6)-β-D-glucopyranoside (named ginsenoside IV) and 3-O-β-D-glucopyranosyl(1,2)-β-D-glucopyranosyl-3β,12β,20(S),24(R)-tetra hydroxy-dammar-25-ene-20-O-β-D-glucopyranosyl(1,6)-β-D-glucopyranoside (ginsenoside V), respectively. The fully established structures were consistent with the MS-oriented structural elucidation. This study expanded our understanding on ginsenosides of Panax species, and the

  2. Extraction and analysis of intact glucosinolates--a validated pressurized liquid extraction/liquid chromatography-mass spectrometry protocol for Isatis tinctoria, and qualitative analysis of other cruciferous plants.

    Science.gov (United States)

    Mohn, Tobias; Cutting, Brian; Ernst, Beat; Hamburger, Matthias

    2007-09-28

    Glucosinolates have attracted significant interest due to the chemopreventive properties of some of their transformation products. Numerous protocols for the extraction and analysis of glucosinolates have been published, but limited effort has been devoted to optimize and validate crucial extraction parameters and sample preparation steps. We carried out a systematic optimization and validation of a quantitative assay for the direct analysis of intact glucosinolates in Isatis tinctoria leaves (woad, Brassicaceae). Various parameters such as solvent composition, particle size, temperature, and number of required extraction steps were optimized using pressurized liquid extraction (PLE). We observed thermal degradation of glucosinolates at temperatures above 50 degrees C, and loss of >60% within 10min at 100 degrees C, but no enzymatic degradation in the leaf samples at ambient temperature. Excellent peak shape and resolution was obtained by reversed-phase chromatography on a Phenomenex Aqua column using 10mM ammonium formate as ion-pair reagent. Detection was carried out by electrospray ionisation mass spectrometry in the negative ion mode. Analysis of cruciferous vegetables and spices such as broccoli (Brassica oleracea L. var. italica), garden cress (Lepidium sativum L.) and black mustard (Sinapis nigra L.) demonstrated the general applicability of the method.

  3. Time resolution research in liquid scintillating detection

    International Nuclear Information System (INIS)

    He Hongkun; Shi Haoshan

    2006-01-01

    The signal processing design method is introduced into liquid scintillating detection system design. By analyzing the signal of liquid scintillating detection, improving time resolution is propitious to upgrade efficiency of detecting. The scheme of realization and satisfactory experiment data is demonstrated. Besides other types of liquid scintillating detection is the same, just using more high speed data signal processing techniques and elements. (authors)

  4. Determination of Human-Health Pharmaceuticals in Filtered Water by Chemically Modified Styrene-Divinylbenzene Resin-Based Solid-Phase Extraction and High-Performance Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Werner, Stephen L.; Anderson, Bruce D.; Cahill, Jeffery D.

    2008-01-01

    In 1999, the Methods Research and Development Program of the U.S. Geological Survey National Water Quality Laboratory began the process of developing a method designed to identify and quantify human-health pharmaceuticals in four filtered water-sample types: reagent water, ground water, surface water minimally affected by human contributions, and surface water that contains a substantial fraction of treated wastewater. Compounds derived from human pharmaceutical and personal-care product use, which enter the environment through wastewater discharge, are a newly emerging area of concern; this method was intended to fulfill the need for a highly sensitive and highly selective means to identify and quantify 14 commonly used human pharmaceuticals in filtered-water samples. The concentrations of 12 pharmaceuticals are reported without qualification; the concentrations of two pharmaceuticals are reported as estimates because long-term reagent-spike sample recoveries fall below acceptance criteria for reporting concentrations without qualification. The method uses a chemically modified styrene-divinylbenzene resin-based solid-phase extraction (SPE) cartridge for analyte isolation and concentration. For analyte detection and quantitation, an instrumental method was developed that used a high-performance liquid chromatography/mass spectrometry (HPLC/MS) system to separate the pharmaceuticals of interest from each other and coextracted material. Immediately following separation, the pharmaceuticals are ionized by electrospray ionization operated in the positive mode, and the positive ions produced are detected, identified, and quantified using a quadrupole mass spectrometer. In this method, 1-liter water samples are first filtered, either in the field or in the laboratory, using a 0.7-micrometer (um) nominal pore size glass-fiber filter to remove suspended solids. The filtered samples then are passed through cleaned and conditioned SPE cartridges at a rate of about 15

  5. Urinary detection of conjugated and unconjugated anabolic steroids by dilute-and-shoot liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Tudela, Eva; Deventer, Koen; Geldof, Lore; Van Eenoo, Peter

    2015-02-01

    Anabolic androgenic steroids (AAS) are an important class of doping agents. The metabolism of these substances is generally very extensive and includes phase-I and phase-II pathways. In this work, a comprehensive detection of these metabolites is described using a 2-fold dilution of urine and subsequent analysis by liquid chromatography-high resolution mass spectrometry (LC-HRMS). The method was applied to study 32 different metabolites, excreted free or conjugated (glucuronide or sulfate), which permit the detection of misuse of at least 21 anabolic steroids. The method has been fully validated for 21 target compounds (8 glucuronide, 1 sulfate and 12 free steroids) and 18 out of 21 compounds had detection limits in the range of 1-10 ng mL(-1) in urine. For the conjugated compounds, for which no reference standards are available, metabolites were synthesized in vitro or excretion studies were investigated. The detection limits for these compounds ranged between 0.5 and 18 ng mL(-1) in urine. The simple and straightforward methodology complements the traditional methods based on hydrolysis, liquid-liquid extraction, derivatization and analysis by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). Copyright © 2014 John Wiley & Sons, Ltd.

  6. Comprehensive analysis of a multidimensional liquid chromatography mass spectrometry dataset acquired on a quadrupole selecting, quadrupole collision cell, time-of-flight mass spectrometer: I. How much of the data is theoretically interpretable by search engines?

    Science.gov (United States)

    Chalkley, Robert J; Baker, Peter R; Hansen, Kirk C; Medzihradszky, Katalin F; Allen, Nadia P; Rexach, Michael; Burlingame, Alma L

    2005-08-01

    An in-depth analysis of a multidimensional chromatography-mass spectrometry dataset acquired on a quadrupole selecting, quadrupole collision cell, time-of-flight (QqTOF) geometry instrument was carried out. A total of 3269 CID spectra were acquired. Through manual verification of database search results and de novo interpretation of spectra 2368 spectra could be confidently determined as predicted tryptic peptides. A detailed analysis of the non-matching spectra was also carried out, highlighting what the non-matching spectra in a database search typically are composed of. The results of this comprehensive dataset study demonstrate that QqTOF instruments produce information-rich data of which a high percentage of the data is readily interpretable.

  7. Simultaneous determination of five major compounds in the traditional medicine Pyeongwee-San by high performance liquid chromatography-diode array detection and liquid chromatography-mass spectrometry/mass spectrometry.

    Science.gov (United States)

    Lee, Bohyoung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Pyeongwee-San (PWS) has been widely used for treating acute gastritis, chronic, and gastritis. In this paper, simultaneous determination of five compounds (naringin, hesperidin, glycyrrhizin, atractylenolide III, and magnolol) from traditional medicine PWS using the high performance liquid chromatography (HPLC) was established for quality control. Optimum separations were obtained with a SHISEIDO C18 reverse-phase column by gradient elution with 0.1% Trifluoroacetic acid (TFA) water-acetonitrile as the mobile phase. The flow rate was 1 mL/min and detection wavelength was set at 205 nm and 250 nm. Validation of the analytical method was evaluated by linearity, precision, and accuracy test. The calibration curves were linear over the established range with R (2) > 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.09 to 0.43 and 0.27 to 1.29 μg/mL. The method exhibited intra-day and inter-day precision range between 0.01-1.86% and 0.04-0.35% respectively. The recoveries of five compounds in PWS were in the range between 93.18-106.40%, and 0.20-1.51%. The application of this method was identified through the successful analysis of five compounds in 12 batches of PWS. In addition, identification of five compounds was confirmed by a liquid chromatography method and mass spectrometry. The HPLC method was could be accomplished to the quality control and stable experiment for the preparations consisted of five major compounds.

  8. Quantification of free and total bisphenol A and bisphenol B in human urine by dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography-mass spectrometry (MD-GC/MS).

    Science.gov (United States)

    Cunha, S C; Fernandes, J O

    2010-11-15

    A novel method combining dispersive liquid-liquid microextraction (DLLME) and heart-cutting multidimensional gas chromatography coupled to mass spectrometry was developed for the determination of free and total bisphenol A (BPA) and bisphenol B (BPB) in human urine samples. The DLLME procedure combines extraction, derivatization and concentration of the analytes into one step. Several important variables influencing the extraction efficiency and selectivity such as nature and volume of extractive and dispersive solvents as well as the amount of acetylating reagent were investigated. The temperature and time to hydrolyze BPA and BPB conjugates with a β-glucuronidase and sulfatase enzyme preparation were also studied. Under the optimized conditions good efficiency extraction (71-93%) and acceptable total DLLME yields (56-77%) were obtained for both analytes. Matrix-matched calibration curves were linear with correlation coefficients higher than 0.996 in the range level 0.1-5 μg/l, and the relative standard deviations (%RSD) were lower than 20% (n=6). The limits of detection were 0.03 and 0.05 μg/l for BPA and BPB, respectively. The applicability of the proposed method for determining urinary free and total BPA and BPB was assessed by analyzing the human urine of a group of 20 volunteers. Free BPA was detected in 45% of the sample whereas total BPA was detected in 85% of the samples at concentrations ranging between 0.39 and 4.99 μg/l. BPB was detected in conjugated form in two samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry

    NARCIS (Netherlands)

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-01-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry

  10. Simultaneous liquid chromatography/mass spectrometry determination of both polar and "multiresidue" pesticides in food using parallel hydrophilic interaction/reversed-phase liquid chromatography and a hybrid sample preparation approach.

    Science.gov (United States)

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2017-09-29

    Pesticide testing of foodstuffs is usually accomplished with generic wide-scope multi-residue methods based on liquid chromatography tandem mass spectrometry (LC-MS/MS). However, this approach does not cover some special pesticides, the so called "single-residue method" compounds, that are hardly compatible with standard reversed-phase (RP) separations due to their specific properties. In this article, we propose a comprehensive strategy for the integration of single residue method compounds and standard multiresidue pesticides within a single run. It is based on the use of a parallel LC column assembly with two different LC gradients performing orthogonal hydrophilic interaction chromatography (HILIC) and reversed-phase (RPLC) chromatography within one analytical run. Two sample aliquots were simultaneously injected on each column, using different gradients, being the eluents merged post-column prior to mass spectrometry detection. The approach was tested with 41 multiclass pesticides covering a wide range of physicochemical properties across several orders of log K ow (from -4 to +5.5). With this assembly, distinct separation from the void was attained for all the pesticides studied, keeping similar performance in terms of sensitivity, peak area reproducibility (pesticides) method was evaluated based on solvent extraction with MeOH and acetonitrile followed by dispersive solid-phase extraction, delivering appropriate recoveries for most of the pesticides included in the study within the log K ow in the range from -4 to +5.5. The proposed strategy may be extended to other fields such as sport drug testing or environmental analysis, where the same type of variety of analytes featuring poor retention within a single chromatographic separation occurs. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 气相色谱质谱联用法测定液氧中微量的氪和氙%Determination of trace krypton and xenon in liquid oxygen by Gas Chromatography/Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    唐轩; 陈鹰; 吴建军

    2013-01-01

    Trace krypton and xenon was determined by gas chromatography/mass spectrometry with selection ion monitoring mode (SIM). The ions m/z=84 and m/z=132 were chosen as quantitative ion for krypton and xenon respectively. The results show that it is a simple way to implement, rapid detection and good selectivity. The linear relation between the peak area and concentration was excellent within the range of (1.0~100)×10-6 V/V. Meanwhile, the minimum detectable concentration and repeatability was also detected.%利用气相色谱质谱联用技术中的选择离子监测(SIM)方式对液氧中的微量氪气和氙气进行了测定。选择m/z为84的离子作为氪的定量离子、m/z为132的离子作为氙的定量离子。方法简单、快速、选择性好,在浓度为(1.0~100)×10-6 V/V范围内,峰面积与浓度有良好的线性关系。同时考察了方法的最低检测浓度和重复性。

  12. Studies on the analysis of benzo(a)pyrene and its metabolites in biological samples by using high performance liquid chromatography/fluorescence detection and gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Lee, Won; Hong, Jee Eun; Shin, Hye Seung; Pyo, Hee Soo; Kim, Yun Je

    2003-01-01

    An analytical method the determination of benzo(a)pyrene (BaP) and its hydroxylated metabolites, 1-hydroxybenzo(a)pyrene (1-OHBaP), 3-hydroxybenzo(a)pyrene (3-OHBaP), benzo(a)pyrene-4,5-dihydrodial(4,5-diolBaP) and benzo(a)pyrene-7,8-dihydrodiol (7,8-diolBaP), in rat urine and plasma has been developed by HPLC/FLD and GC/MS. The derivatization with alkyl iodide was employed to improve the resolution and the detection of two mono hydroxylated metabolites, 1-OHBaP and 3-OHBaP, in LC and GC. BaP and its four metabolites in spiked urine were successfully separated by gradient elution on reverse phase ODS C 18 column (4.6 mm I.D., 100 mm length, particle size 5μm) using a binary mixture of MeOH/H 2 O (85/15, v/v) as mobile phase after ethylation at 90 .deg. C for 10 min. The extraction recoveries of BaP and its metabolites in spiked samples with liquid-liquid extraction, which was better than solid phase extraction, were in the range of 90.3-101.6% in n-hexane for urine and 95.7-106.3% in acetone for plasma, respectively. The calibration curves has shown good linearity with the correlation coefficients (R 2 ) varying from 0.992 to 1.000 for urine and from 0.996 to 1.000 for plasma, respectively. The detection limits of all analytes were obtained in the range of 0.01-0.1 ng/mL for urine and 0.1-0.4ng/mL for plasma, respectively. The metabolites of BaP were excreted as mono hydroxy and dihydrodiol forms after intraperitoneal infection of 20 mg/kg of BaP to rats. The total amounts of BaP and four metabolites excreted in dosed rat urine were 3.79 ng over the 0 - 96 hr period from administration and the excretional recovery was less than 0.065% of the injection amounts of BaP. The proposed method was successfully applied to the determination of BaP and its hydroxylated metabolites in rat urine and plasma for the pharmacokinetic studies

  13. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group - Determination of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Water Using Online Solid-Phase Extraction and High-Performance Liquid Chromatography/Mass Spectrometry

    National Research Council Canada - National Science Library

    Lee, E. A; Strahan, A. P; Thurman, E. M

    2002-01-01

    ...). After derivatization, cleanup and concentration were accomplished using automated online solidphase extraction followed by elution with the mobile phase allowing for direct injection into a liquid...

  14. High Resolution Displays Using NCAP Liquid Crystals

    Science.gov (United States)

    Macknick, A. Brian; Jones, Phil; White, Larry

    1989-07-01

    Nematic curvilinear aligned phase (NCAP) liquid crystals have been found useful for high information content video displays. NCAP materials are liquid crystals which have been encapsulated in a polymer matrix and which have a light transmission which is variable with applied electric fields. Because NCAP materials do not require polarizers, their on-state transmission is substantially better than twisted nematic cells. All dimensional tolerances are locked in during the encapsulation process and hence there are no critical sealing or spacing issues. By controlling the polymer/liquid crystal morphology, switching speeds of NCAP materials have been significantly improved over twisted nematic systems. Recent work has combined active matrix addressing with NCAP materials. Active matrices, such as thin film transistors, have given displays of high resolution. The paper will discuss the advantages of NCAP materials specifically designed for operation at video rates on transistor arrays; applications for both backlit and projection displays will be discussed.

  15. A study of thermaů decomposition and combustion products of disposable polyethylene terephtalate plastic using high resolution fourier transform infrared spectroscopy, selected ion flow tube mass spectrometry and gas chromatography mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Sovová, Kristýna; Ferus, Martin; Matulková, Irena; Španěl, Patrik; Dryahina, Kseniya; Dvořák, O.; Civiš, Svatopluk

    2008-01-01

    Roč. 106, 9-10 (2008), s. 1205-1214 ISSN 0026-8976 R&D Projects: GA AV ČR IAA400400705; GA ČR GA202/06/0776 Institutional research plan: CEZ:AV0Z40400503 Keywords : polyethylene terephtalate (PET) * combustion * high resolution FTIR spectroscopy * GC-MS * SIFT-MS Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.478, year: 2008

  16. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group--Determination of Triazine and Phenylurea Herbicides and Their Degradation Products in Water Using Solid-Phase Extraction and Liquid Chromatography/Mass Spectrometry

    National Research Council Canada - National Science Library

    Lee, E. A; Strahan, A. P; Thurman, E. M

    2002-01-01

    An analytical method for the determination of 7 triazine and phenylurea herbicides and 12 of their degradation products in natural water samples using solid-phase extraction and liquid chromatography...

  17. Gas Chromatography Mass Spectrometry of Quassia undulata Seed ...

    African Journals Online (AJOL)

    Prof. Ogunji

    The use of gas chromatography mass spectrometry (GC MS) as a sensitive and specific technique ... cold flow properties and stability of the fuel to oxidation, peroxidation and polymerization .... determinants of both the physical and chemical ...

  18. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    HP

    Original Research Article. Gas Chromatography-Mass Spectrometric Analysis and ... into a natural fumigant/insecticide for the control of stored product insects. Keywords: Mallotus ..... stability as well as reduce cost. ACKNOWLEDGEMENT.

  19. Gas Chromatography-Mass Spectrometric Analysis of Nematicidal ...

    African Journals Online (AJOL)

    Gas Chromatography-Mass Spectrometric Analysis of Nematicidal Essential Oil of Valeriana ... Tropical Journal of Pharmaceutical Research ... have a potential to be developed to natural nematicides for the control of cereal cyst nematodes.

  20. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... apelta aerial parts was analyzed by gas chromatography/mass spectrometric (GC/MS) to determine its composition. ... into a natural fumigant/insecticide for the control of stored product insects.

  1. Prediction of Molar Extinction Coefficients of Proteins and Peptides Using UV Absorption of the Constituent Amino Acids at 214 nm To Enable Quantitative Reverse Phase High-Performance Liquid Chromatography-Mass Spectrometry Analysis

    NARCIS (Netherlands)

    Kuipers, B.J.H.; Gruppen, H.

    2007-01-01

    The molar extinction coefficients of 20 amino acids and the peptide bond were measured at 214 nm in the presence of acetonitrile and formic acid to enable quantitative comparison of peptides eluting from reversed-phase high-performance liquid chromatography, once identified with mass spectrometry

  2. Identification of inorganic anions by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Sakayanagi, Masataka; Yamada, Yaeko; Sakabe, Chikako; Watanabe, Kunio; Harigaya, Yoshihiro

    2006-03-10

    Inorganic anions were identified by using gas chromatography/mass spectrometry (GC/MS). Derivatization of the anions was achieved with pentafluorobenzyl p-toluenesulphonate (PFB-Tos) as the reaction reagent and a crown ether as a phase transfer catalyst. When PFB-Br was used as the reaction reagent, the retention time of it was close to those of the derivatized inorganic anions and interfered with the analysis. In contrast, the retention time of PFB-Tos differed greatly from the PFB derivatives of the inorganic anions and the compounds of interest could be detected without interference. Although the PFB derivatives of SO4, S2O3, CO3, ClO4, and ClO3 could not be detected, the derivatives of F, Cl, Br, I, CN, OCN, SCN, N3, NO3, and NO2 were detected using PFB-Tos as the derivatizing reagent. The inorganic anions were detectable within 30 ng approximately, which is of sufficient sensitivity for use in forensic chemistry. Accurate mass number was measured for each PFB derivative by high-resolution mass spectrometry (HRMS) within a measurement error of 2 millimass units (mmu), which allowed determination of the compositional formula from the mass number. In addition, actual analysis was performed successively by our method using trial samples of matrix.

  3. Characterization of the pigment fraction in sweet bell peppers (Capsicum annuum L.) harvested at green and overripe yellow and red stages by offline multidimensional convergence chromatography/liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bonaccorsi, Ivana; Cacciola, Francesco; Utczas, Margita; Inferrera, Veronica; Giuffrida, Daniele; Donato, Paola; Dugo, Paola; Mondello, Luigi

    2016-09-01

    Offline multidimensional supercritical fluid chromatography combined with reversed-phase liquid chromatography was employed for the carotenoid and chlorophyll characterization in different sweet bell peppers (Capsicum annuum L.) for the first time. The first dimension consisted of an Acquity HSS C18 SB (100 × 3 mm id, 1.8 μm particles) column operated with a supercritical mobile phase in an ultra-performance convergence chromatography system, whereas the second dimension was performed in reversed-phase mode with a C30 (250 × 4.6 mm id, 3.0 μm particles) stationary phase combined with photodiode array and mass spectrometry detection. This approach allowed the determination of 115 different compounds belonging to chlorophylls, free xanthophylls, free carotenes, xanthophyll monoesters, and xanthophyll diesters, and proved to be a significant improvement in the pigments determination compared to the conventional one-dimensional liquid chromatography approach so far applied to the carotenoid analysis in the studied species. Moreover, the present study also aimed to investigate and to compare the carotenoid stability and composition in overripe yellow and red bell peppers collected directly from the plant, thus also evaluating whether biochemical changes are linked to carotenoid degradation in the nonclimacteric investigated fruits, for the first time. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Furanic compounds and furfural in different coffee products by headspace liquid-phase micro-extraction followed by gas chromatography-mass spectrometry: survey and effect of brewing procedures.

    Science.gov (United States)

    Chaichi, Maryam; Ghasemzadeh-Mohammadi, Vahid; Hashemi, Maryam; Mohammadi, Abdorreza

    2015-01-01

    In this study, the levels of furan, 2-methylfuran, 2,5-dimethylfuran, vinyl furan, 2-methoxymethyl-furan and furfural in different coffee products were evaluated. Simultaneous determination of these six furanic compounds was performed by a head space liquid-phase micro-extraction (HS-LPME) method. A total of 67 coffee powder samples were analysed. The effects of boiling and espresso-making procedures on the levels of furanic compounds were investigated. The results showed that different types of coffee samples contained different concentrations of furanic compounds, due to the various processing conditions such as temperature, degree of roasting and fineness of grind. Among the different coffee samples, the highest level of furan (6320 µg kg⁻¹) was detected in ground coffee, while coffee-mix samples showed the lowest furan concentration (10 µg kg⁻¹). Levels in brewed coffees indicated that, except for furfural, brewing by an espresso machine caused significant loss of furanic compounds.

  5. New Methodologies for Qualitative and Semi-Quantitative Determination of Carbon-Centered Free Radicals in Cigarette Smoke Using Liquid ChromatographyTandem Mass Spectrometry and Gas Chromatography-Mass Selective Detection

    Directory of Open Access Journals (Sweden)

    Gerardi AR

    2014-12-01

    Full Text Available Several approaches were explored to develop a high throughput procedure for relative determination of 14 different carbon-centered free radicals, both acyl and alkylaminocarbonyl type, in cigarette smoke. Two trapping procedures using 3-cyano-2,2,5,5-tetramethyl-1-pyrrolidinyloxy, or 3-cyanoproxyl radical (3-CNP were designed for this study: a trapping in solution and b trapping on a solid support which was a Cambridge filter pad. Fresh whole smoke and vapor phase smoke from mainstream cigarette smoke from Kentucky Reference Cigarettes 2R4F, as partitioned via an unadulterated Cambridge filter pad, were transferred into each trapping system in separate experiments. The 3-CNP coated Cambridge filter pad approach was shown to be superior to the impinger procedure as described in this study. Gas chromatography coupled with mass selective detection (GC-MS was employed for the first time as an alternate means of detecting several relatively highly concentrated radical adducts. Liquid chromatography tandem mass spectrometry (LC-MS/MS with precursor ion monitoring and selected ion monitoring (SIM was used for detecting the large array of radicals, including several not previously reported: formyl, crotonyl, acrolein, aminocarbonyl, and anilinocarbonyl radicals. Relative quantitation was achieved using as external calibration standards of 4-(1-pyrrolidinobenzaldehyde and nicotine. It was determined that the yield of carbon-centered free radicals by reference cigarette 2R4F was approximately 265 nmoles/cigarette at 35 mL puff/60 sec interval/2 sec duration smoking conditions.

  6. Data Generated by Quantitative Liquid Chromatography-Mass Spectrometry Proteomics Are Only the Start and Not the Endpoint: Optimization of Quantitative Concatemer-Based Measurement of Hepatic Uridine-5'-Diphosphate-Glucuronosyltransferase Enzymes with Reference to Catalytic Activity.

    Science.gov (United States)

    Achour, Brahim; Dantonio, Alyssa; Niosi, Mark; Novak, Jonathan J; Al-Majdoub, Zubida M; Goosen, Theunis C; Rostami-Hodjegan, Amin; Barber, Jill

    2018-06-01

    Quantitative proteomic methods require optimization at several stages, including sample preparation, liquid chromatography-tandem mass spectrometry (LC-MS/MS), and data analysis, with the final analysis stage being less widely appreciated by end-users. Previously reported measurement of eight uridine-5'-diphospho-glucuronosyltransferases (UGT) generated by two laboratories [using stable isotope-labeled (SIL) peptides or quantitative concatemer (QconCAT)] reflected significant disparity between proteomic methods. Initial analysis of QconCAT data showed lack of correlation with catalytic activity for several UGTs (1A4, 1A6, 1A9, 2B15) and moderate correlations for UGTs 1A1, 1A3, and 2B7 ( R s = 0.40-0.79, P data analysis, starting from unprocessed LC-MS/MS data, was undertaken, with the aim of improving accuracy, defined by correlation against activity. Three main criteria were found to be important: choice of monitored peptides and fragments, correction for isotope-label incorporation, and abundance normalization using fractional protein mass. Upon optimization, abundance-activity correlations improved significantly for six UGTs ( R s = 0.53-0.87, P data analysis strategy and indicates, using examples, the significance of systematic data processing following acquisition. The proposed strategy offers significant improvement on existing guidelines applicable to clinically relevant proteins quantified using QconCAT. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.

  7. Magnetic dispersive solid-phase extraction based on modified magnetic nanoparticles for the detection of cocaine and cocaine metabolites in human urine by high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Feiyu; Zou, Yun; Ni, Chunfang; Wang, Rong; Wu, Min; Liang, Chen; Zhang, Jiabin; Yuan, Xiaoliang; Liu, Wenbin

    2017-11-01

    An easy-to-handle magnetic dispersive solid-phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe 3 O 4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high-performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid-phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09-1.10 ng/mL. The proposed magnetic dispersive solid-phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Application of a new procedure for liquid chromatography/mass spectrometry profiling of plasma amino acid-related metabolites and untargeted shotgun proteomics to identify mechanisms and biomarkers of calcific aortic stenosis.

    Science.gov (United States)

    Olkowicz, Mariola; Debski, Janusz; Jablonska, Patrycja; Dadlez, Michal; Smolenski, Ryszard T

    2017-09-29

    Calcific aortic valve stenosis (CAS) increasingly affects our ageing population, but the mechanisms of the disease and its biomarkers are not well established. Recently, plasma amino acid-related metabolite (AA) profiling has attracted attention in studies on pathology and development of biomarkers of cardiovascular diseases, but has not been studied in CAS. To evaluate the potential relationship between CAS and AA metabolome, a new ion-pairing reversed-phase liquid chromatography-tandem mass spectrometry (IP-RPLC-MS/MS) method has been developed and validated for simultaneous determination of 43 AAs in plasma of stenotic patients and age-matched control subjects. Furthermore, untargeted mass spectrometry-based proteomic analysis and confirmatory ELISA assays were performed. The method developed offered high accuracy (intra-assay imprecision averaged 4.4% for all compounds) and sensitivity (LOQ within 0.01-0.5μM). We found that 22 AAs and three AA ratios significantly changed in the CAS group as compared to control. The most pronounced differences were observed in urea cycle-related AAs and branched-chain AA (BCAA)-related AAs. The contents of asymmetric dimethylarginine (ADMA) and its monomethylated derivative (NMMA) were increased by 30-64% with CAS. The arginine/ADMA and Fischer's ratios as well as arginine, homoarginine, ADMA, symmetric dimethylarginine, hydroxyproline, betaine and 3-methylhistidine correlated with cardiac function-related parameters and concomitant systemic factors in the CAS patients. The results of proteomic analysis were consistent with involvement of inflammation, lipid abnormalities, hemostasis and extracellular matrix remodeling in CAS. In conclusion, changes in plasma AA profile and protein pattern that we identified in CAS provide information relevant to pathomechanisms and may deliver new biomarkers of the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A method for screening active components from Chinese herbs by cell membrane chromatography-offline-high performance liquid chromatography/mass spectrometry and an online statistical tool for data processing.

    Science.gov (United States)

    Cao, Yan; Wang, Shaozhan; Li, Yinghua; Chen, Xiaofei; Chen, Langdong; Wang, Dongyao; Zhu, Zhenyu; Yuan, Yongfang; Lv, Diya

    2018-03-09

    Cell membrane chromatography (CMC) has been successfully applied to screen bioactive compounds from Chinese herbs for many years, and some offline and online two-dimensional (2D) CMC-high performance liquid chromatography (HPLC) hyphenated systems have been established to perform screening assays. However, the requirement of sample preparation steps for the second-dimensional analysis in offline systems and the need for an interface device and technical expertise in the online system limit their extensive use. In the present study, an offline 2D CMC-HPLC analysis combined with the XCMS (various forms of chromatography coupled to mass spectrometry) Online statistical tool for data processing was established. First, our previously reported online 2D screening system was used to analyze three Chinese herbs that were reported to have potential anti-inflammatory effects, and two binding components were identified. By contrast, the proposed offline 2D screening method with XCMS Online analysis was applied, and three more ingredients were discovered in addition to the two compounds revealed by the online system. Then, cross-validation of the three compounds was performed, and they were confirmed to be included in the online data as well, but were not identified there because of their low concentrations and lack of credible statistical approaches. Last, pharmacological experiments showed that these five ingredients could inhibit IL-6 release and IL-6 gene expression on LPS-induced RAW cells in a dose-dependent manner. Compared with previous 2D CMC screening systems, this newly developed offline 2D method needs no sample preparation steps for the second-dimensional analysis, and it is sensitive, efficient, and convenient. It will be applicable in identifying active components from Chinese herbs and practical in discovery of lead compounds derived from herbs. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Radiogas chromatography mass spectrometry in the selected ion monitoring mode

    International Nuclear Information System (INIS)

    Doerfler, D.L.; Rosenblum, E.R.; Malloy, J.M.; Naworal, J.D.; McManus, I.R.; Campbell, I.M.

    1980-01-01

    The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid in Penicillium brevicompactum and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. Both examples used 1-[ 14 C]acetate precursors. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed. (author)

  11. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  12. Liquid chromatography mass spectrometry for analysis of microbial metabolites

    DEFF Research Database (Denmark)

    Klitgaard, Andreas

    to human health. Because of this, methods for detection and analysis of these compounds are vital. Estimates suggest that there are around 1.5 million different fungal species on Earth, dwarfing the number of plants estimated to 300,000, meaning that there potentially are many more interesting compounds...... is of large commercial interest for production of the bioactive compounds of the future. One part of my study focused on identification and elucidation of the biosynthesis of a nonribosomal peptide (NRP) nidulanin A from Aspergillus nidulans. Although the study was successful several analogs were......Filamentous fungi serve a very important role in Nature where they break down organic matter, releasing nutrients that can be used by other organisms. Fungi and other microorganisms also produce a wide array of bioactive compounds, the secondary metabolites( SMs), used for such diverse roles...

  13. Liquid chromatography-mass spectrometry-based quantitative proteomics.

    Science.gov (United States)

    Linscheid, Michael W; Ahrends, Robert; Pieper, Stefan; Kühn, Andreas

    2009-01-01

    During the last decades, molecular sciences revolutionized biomedical research and gave rise to the biotechnology industry. During the next decades, the application of the quantitative sciences--informatics, physics, chemistry, and engineering--to biomedical research brings about the next revolution that will improve human healthcare and certainly create new technologies, since there is no doubt that small changes can have great effects. It is not a question of "yes" or "no," but of "how much," to make best use of the medical options we will have. In this context, the development of accurate analytical methods must be considered a cornerstone, since the understanding of biological processes will be impossible without information about the minute changes induced in cells by interactions of cell constituents with all sorts of endogenous and exogenous influences and disturbances. The first quantitative techniques, which were developed, allowed monitoring relative changes only, but they clearly showed the significance of the information obtained. The recent advent of techniques claiming to quantify proteins and peptides not only relative to each other, but also in an absolute fashion, promised another quantum leap, since knowing the absolute amount will allow comparing even unrelated species and the definition of parameters will permit to model biological systems much more accurate than before. To bring these promises to life, several approaches are under development at this point in time and this review is focused on those developments.

  14. Determination of sulfadiazine, trimethoprim, and N(4) -acetyl-sulfadiazine in fish muscle plus skin by Liquid Chromatography-Mass Spectrometry. Withdrawal-time calculation after in-feed administration in gilthead sea bream (Sparus aurata L.) fed two different diets.

    Science.gov (United States)

    Zonaras, V; Tyrpenou, A; Alexis, M; Koupparis, M

    2016-10-01

    This study presents a depletion study for sulfadiazine and trimethoprim in muscle plus skin of gilthead sea bream (Sparus aurata L.). N(4) -acetyl-sulfadiazine, the main metabolite of sulfadiazine (SDZ), was also examined. The fish were held in seawater at a temperature of 24-26 °C. SDZ and trimethoprim (TMP) were administered orally with medicated feed for five consecutive days at daily doses of 25 mg SDZ and 5 mg TMP per kg of fish body weight per day. Two different diets, fish oil- and plant oil-based diets, were investigated. Ten fish were sampled at each of the days 1, 3, 5, 6, 8, 9, 10, and 12 after the start of veterinary medicine administration. However for the calculation of the withdrawal periods, sampling day 1 was set as 24 h after the last dose of the treatment. Fish samples were analyzed for SDZ, TMP, and acetyl-sulfadiazine (AcSDZ) residues by liquid chromatography-mass spectrometry. SDZ and TMP concentrations declined rapidly from muscle plus skin. Considering a maximum residue limit of 100 μg/kg for the total of sulfonamides and 50 μg/kg for TMP residues in fish muscle plus skin, the withdrawal periods of the premix trimethoprim-sulfadiazine 50% were calculated as 5 and 6 days, at 24-26 °C, in fish oil (FO) and plant oil (PO) groups, respectively. The investigation of this work is important to protect consumers by controlling the undesirable residues in fish. © 2016 John Wiley & Sons Ltd.

  15. Elucidation and identification of amino acid containing membrane lipids using liquid chromatography/high-resolution mass spectrometry

    NARCIS (Netherlands)

    Moore, E.K.; Hopmans, E.C.; Rijpstra, W.I.C.; Villanueva, L.; Sinninghe Damsté, J.S.

    2016-01-01

    RATIONALE: Intact polar lipids (IPLs) are the building blocks of cell membranes, and amino acid containing IPLs havebeen observed to be involved in response to changing environmental conditions in various species of bacteri a. High-performance liquid chromatography/mass spectrometry (HPLC/MS) has

  16. Energy resolution in liquid argon doped with allene

    International Nuclear Information System (INIS)

    Ichinose, H.; Doke, T.; Masuda, K.; Shibamura, E.

    1989-01-01

    Studies have been made on liquid argon as detection medium with large volume and good energy and position resolution. It is advantageous to dope liquid argon with molecules with an ionization potential lower than the energy of scintillation light. In the present work, the energy resolution for 5.305MeV alpha particles is examined, and the effect of allene added to liquid argon is investigated. Some preliminary results for 976 KeV electrons are also presented. Allene is purified by two methods: (a) small-quantity purification and (b) mass purification. Three methods are tried for mixing allene with argon. Results concerning the allene purification methods, effect of allene concentration, and allene-argon mixing methods are presented. Discussion is made of the collected charge and energy resolution. It is concluded that the addition of allene to liquid argon greatly improves the energy resolution of 5.305 MeV alpha particles. The best intrinsic resolution is 1.4 percent FWHM obtained for 4 ppm allene doped liquid argon. In the case of 976 KeV electron radiation, energy resolution is not improved by adding allene to liquid argon. The best resolution is 31 KeV FWHM obtaiend for 65ppm allene doped liquid argon. (N.K.)

  17. Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum

    Czech Academy of Sciences Publication Activity Database

    Pilařová, V.; Gottvald, T.; Svoboda, P.; Novák, Ondřej; Benešová, K.; Běláková, S.; Nováková, L.

    2016-01-01

    Roč. 934, AUG 31 (2016), s. 252-265 ISSN 0003-2670 R&D Projects: GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Ultra-high performance supercritical fluid chromatography * Mass spectrometry * Liquid liquid extraction Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.950, year: 2016

  18. Chlorococcalean microalgae Ankistrodesmus convolutes biodiesel characterization with Fourier transform-infrared spectroscopy and gas chromatography mass spectroscopy techniques

    Directory of Open Access Journals (Sweden)

    Swati SONAWANE

    2015-12-01

    Full Text Available The Chlorococcalean microalgae Ankistrodesmus convolutes was found in fresh water Godawari reservoir, Ahmednagar district of Maharashtra State, India. Microalgae are modern biomass for the production of liquid biofuel due to its high solar cultivation efficiency. The collection, harvesting and drying processes were play vital role in converting algal biomass into energy liquid fuel. The oil extraction was the important step for the biodiesel synthesis. The fatty acid methyl ester (FAME synthesis was carried through base catalyzed transesterification method. The product was analyzed by using the hyphened techniques like Fourier Transform-Infrared spectroscopy (FT-IR and Gas Chromatography Mass Spectroscopy (GCMS. FT-IR Spectroscopy was results the ester as functional group of obtained product while the Gas Chromatography Mass Spectroscopy was results the six type of fatty acid methyl ester with different concentration. Ankistrodesmus convolutes biodiesel consist of 46.5% saturated and 49.14% unsaturated FAME.

  19. Liquid Scintillation High Resolution Spectral Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2010-08-06

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  20. Liquid Scintillation High Resolution Spectral Analysis

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2010-01-01

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  1. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and

  2. Estimation of brassylic acid by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed J. Nasrullah, Erica N. Pfarr, Pooja Thapliyal, Nicholas S. Dusek, Kristofer L. Schiele, Christy Gallagher-Lein, and James A. Bahr

    2010-10-29

    The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.

  3. Forensic applications of supercritical fluid chromatography - mass spectrometry.

    Science.gov (United States)

    Pauk, Volodymyr; Lemr, Karel

    2018-06-01

    Achievements of supercritical fluid chromatography with mass spectrometric detection made in the field of forensic science during the last decade are reviewed. The main topics include analysis of traditional drugs of abuse (e.g. cannabis, methamphetamine) as well as new psychoactive substances (synthetic cannabinoids, cathinones and phenethylamines), doping agents (anabolic steroids, stimulants, diuretics, analgesics etc.) and chemical warfare agents. Control of food authenticity, detection of adulteration and identification of toxic substances in food are also pointed out. Main aspects of an analytical workflow, such as sample preparation, separation and detection are discussed. A special attention is paid to the performance characteristics and validation parameters of supercritical fluid chromatography-mass spectrometric methods in comparison with other separation techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. DETECTING LOW-LEVEL SYNTHESIS IMPURITIES IN MODIFIED PHOSPHOROTHIOATE OLIGONUCLEOTIDES USING LIQUID CHROMATOGRAPHY – HIGH RESOLUTION MASS SPECTROMETRY

    Science.gov (United States)

    Nikcevic, Irena; Wyrzykiewicz, Tadeusz K.; Limbach, Patrick A.

    2010-01-01

    Summary An LC-MS method based on the use of high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTIRCMS) for profiling oligonucleotides synthesis impurities is described. Oligonucleotide phosphorothioatediesters (phosphorothioate oligonucleotides), in which one of the non-bridging oxygen atoms at each phosphorus center is replaced by a sulfur atom, are now one of the most popular oligonucleotide modifications due to their ease of chemical synthesis and advantageous pharmacokinetic properties. Despite significant progress in the solid-phase oligomerization chemistry used in the manufacturing of these oligonucleotides, multiple classes of low-level impurities always accompany synthetic oligonucleotides. Liquid chromatography-mass spectrometry has emerged as a powerful technique for the identification of these synthesis impurities. However, impurity profiling, where the entire complement of low-level synthetic impurities is identified in a single analysis, is more challenging. Here we present an LC-MS method based the use of high resolution-mass spectrometry, specifically Fourier transform ion cyclotron resonance mass spectrometry (FTIRCMS or FTMS). The optimal LC-FTMS conditions, including the stationary phase and mobile phases for the separation and identification of phosphorothioate oligonucleotides, were found. The characteristics of FTMS enable charge state determination from single m/z values of low-level impurities. Charge state information then enables more accurate modeling of the detected isotopic distribution for identification of the chemical composition of the detected impurity. Using this approach, a number of phosphorothioate impurities can be detected by LC-FTMS including failure sequences carrying 3′-terminal phosphate monoester and 3′-terminal phosphorothioate monoester, incomplete backbone sulfurization and desulfurization products, high molecular weight impurities, and chloral, isobutyryl, and N3 (2-cyanoethyl) adducts

  5. Gas Chromatography-Mass Spectroscopic (GC-MS) Analysis of n ...

    African Journals Online (AJOL)

    tuber-regium (synonym Pleurotus tuber regium) using gas chromatography-mass spectroscopic (GC-. MS) techniques. Methods: The n-hexane extract of the sclerotia ... Soxhlet extraction and analysed using gas chromatography-mass spectroscopic (MS) techniques. ..... Phytochemical composition of Pleurotus tuber regium.

  6. A gas chromatography-mass spectrometry method for the quantitation of clobenzorex.

    Science.gov (United States)

    Cody, J T; Valtier, S

    1999-01-01

    Drugs metabolized to amphetamine or methamphetamine are potentially significant concerns in the interpretation of amphetamine-positive urine drug-testing results. One of these compounds, clobenzorex, is an anorectic drug that is available in many countries. Clobenzorex (2-chlorobenzylamphetamine) is metabolized to amphetamine by the body and excreted in the urine. Following administration, the parent compound was detectable for a shorter time than the metabolite amphetamine, which could be detected for days. Because of the potential complication posed to the interpretation of amphetamin-positive drug tests following administration of this drug, the viability of a current amphetamine procedure using liquid-liquid extraction and conversion to the heptafluorobutyryl derivative followed by gas chromatography-mass spectrometry (GC-MS) analysis was evaluated for identification and quantitation of clobenzorex. Qualitative identification of the drug was relatively straightforward. Quantitative analysis proved to be a far more challenging process. Several compounds were evaluated for use as the internal standard in this method, including methamphetamine-d11, fenfluramine, benzphetamine, and diphenylamine. Results using these compounds proved to be less than satisfactory because of poor reproducibility of the quantitative values. Because of its similar chromatographic properties to the parent drug, the compound 3-chlorobenzylamphetamine (3-Cl-clobenzorex) was evaluated in this study as the internal standard for the quantitation of clobenzorex. Precision studies showed 3-Cl-clobenzorex to produce accurate and reliable quantitative results (within-run relative standard deviations [RSDs] clobenzorex.

  7. Analysis of isothiazolinones in environmental waters by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Rafoth, Astrid; Gabriel, Sabine; Sacher, Frank; Brauch, Heinz-Jürgen

    2007-09-14

    This paper describes an analytical method for the determination of five biocides of isothiazolinone type (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT), 2-octyl-3-isothiazolinone (OI), 4,5-dichloro-2-octyl-3-isothiazolinone (DCOI)) in environmental waters. The method is based on pre-concentration of the analytes by solid-phase extraction onto a mixture of a polymeric material and RP-C18 material and subsequent determination by gas chromatography-mass spectrometry (GC-MS). One of the target compounds (BIT) is derivatised with diazomethane after pre-concentration to improve its chromatographic performance. The method was optimised with respect to pre-concentration conditions (liquid-liquid extraction versus solid-phase extraction, solid-phase material, elution solvent and volume) and extensively validated. Applying the method to surface waters, groundwaters, and drinking waters, limits of detection between 0.01 and 0.1 microg/l could be achieved and the repeatability was below 10% for all compounds except for MI. Additional investigations showed that the stability of the isothiazolinones in environmental waters is limited and sample storage at 4 degrees C is mandatory to preserve the target biocides. First investigations of influents and effluents of a wastewater treatment plant showed that conventional wastewater treatment exhibits a high efficiency for removal of the isothiazolinones. In river waters, the target isothiazolinones could not be detected.

  8. Gas chromatography-mass spectrometry with supersonic molecular beams.

    Science.gov (United States)

    Amirav, Aviv; Gordin, Alexander; Poliak, Marina; Fialkov, Alexander B

    2008-02-01

    Gas chromatography-mass spectrometry (GC-MS) with supersonic molecular beams (SMBs) (also named Supersonic GC-MS) is based on GC and MS interface with SMBs and on the electron ionization (EI) of vibrationally cold analytes in the SMBs (cold EI) in a fly-through ion source. This ion source is inherently inert and further characterized by fast response and vacuum background filtration capability. The same ion source offers three modes of ionization including cold EI, classical EI and cluster chemical ionization (CI). Cold EI, as a main mode, provides enhanced molecular ions combined with an effective library sample identification, which is supplemented and complemented by a powerful isotope abundance analysis method and software. The range of low-volatility and thermally labile compounds amenable for analysis is significantly increased owing to the use of the contact-free, fly-through ion source and the ability to lower sample elution temperatures through the use of high column carrier gas flow rates. Effective, fast GC-MS is enabled particularly owing to the possible use of high column flow rates and improved system selectivity in view of the enhancement of the molecular ion. This fast GC-MS with SMB can be further improved via the added selectivity of MS-MS, which by itself benefits from the enhancement of the molecular ion, the most suitable parent ion for MS-MS. Supersonic GC-MS is characterized by low limits of detection (LOD), and its sensitivity is superior to that of standard GC-MS, particularly for samples that are hard for analysis. The GC separation of the Supersonic GC-MS can be improved with pulsed flow modulation (PFM) GC x GC-MS. Electron ionization LC-MS with SMB can also be combined with the Supersonic GC-MS, with fast and easy switching between these two modes of operation. (c) 2008 John Wiley & Sons, Ltd.

  9. Detection of anabolic and androgenic steroids and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Kwok, Karen Y; Choi, Timmy L S; Kwok, Wai Him; Wong, Jenny K Y; Wan, Terence S M

    2017-04-14

    Anabolic and androgenic steroids (AASs) are a class of prohibited substances banned in horseracing at all times. The common approach for controlling the misuse of AASs in equine sports is by detecting the presence of AASs and/or their metabolites in urine and blood samples using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This approach, however, often falls short as the duration of effect for many AASs are longer than their detection time in both urine and blood. As a result, there is a high risk that such AASs could escape detection in their official race-day samples although they may have been used during the long period of training. Hair analysis, on the other hand, can afford significantly longer detection windows. In addition, the identification of synthetic ester derivatives of AASs in hair, particularly for the endogenous ones, can provide unequivocal proof of their exogenous origin. This paper describes the development of a sensitive method (at sub to low parts-per-billion or ppb levels) for detecting 48 AASs and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS). Decontaminated horse hair was pulverised and subjected to in-situ liquid-liquid extraction in a mixture of hexane - ethyl acetate (7:3, v/v) and phosphate buffer (0.1M, pH 9.5), followed by additional clean-up using mixed-mode solid-phase extraction. The final extract was analysed using UHPLC-HRMS in the positive electrospray ionisation (ESI) mode with both full scan and parallel reaction monitoring (PRM). This method was validated for qualitative identification purposes. Validation data, including method specificity, method sensitivity, extraction recovery, method precision and matrix effect are presented. Method applicability was demonstrated by the successful detection and confirmation of testosterone propionate in a referee hair sample. To our knowledge, this was

  10. Signal yields, energy resolution, and recombination fluctuations in liquid xenon

    Science.gov (United States)

    Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bramante, R.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Phelps, P.; Reichhart, L.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.; LUX Collaboration

    2017-01-01

    This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon recombination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2 and 16 keV with 3H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.

  11. Quantitative analysis of aldehydes in canned vegetables using static headspace-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2017-11-17

    Volatile aldehydes appear in canned vegetables as constituents and some of them can also be present as disinfection by-products (DBPs) because of the contact between vegetables and treated water. This paper describes two static headspace-gas chromatography-mass spectrometry (SHS-GC-MS) methods to determine 15 aldehydes in both the solid and the liquid phases of canned vegetables. The treatment for both phases of samples was carried out simultaneously into an SHS unit, including the leaching of the aldehydes (from the vegetable), their derivatization and volatilization of the oximes formed. Detection limits were obtained within the range of 15-400μg/kg and 3-40μg/L for aldehydes in the solid and the liquid phases of the food, respectively. The relative standard deviation was lower than 7% -for the whole array of the target analytes-, the trueness evaluated by recovery experiments provided %recoveries between 89 and 99% and short- and long-term stability studies indicated there was no significant variation in relative peak areas of all aldehydes in both phases of canned vegetables after their storing at 4°C for two weeks. The study of the origin of the 15 aldehydes detected between both phases of canned vegetables showed that: i) the presence of 13 aldehydes -at average concentrations of 2.2-39μg/kg and 0.25-71μg/L for the solid and the liquid phases, respectively- is because they are natural constituents of vegetables; and ii) the presence of glyoxal and methylglyoxal -which are mainly found in the liquid phase (average values, 1.4-4.1μg/L)- is ascribed to the use of treated water, thereby being DBPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. An appraisal on the degradation of paracetamol by TiO2/UV system in aqueous medium: product identification by gas chromatography-mass spectrometry (GC-MS)

    OpenAIRE

    Dalmázio,Ilza; Alves,Tânia M. A.; Augusti,Rodinei

    2008-01-01

    The advanced oxidation of paracetamol (1) promoted by TiO2/UV system in aqueous medium was investigated. Continuous monitoring by several techniques, such as UV-Vis spectroscopy, HPLC (high performance liquid chromatography), TOC (total organic carbon), and ESI-MS (electrospray ionization mass spectrometry), revealed that whereas the removal of paracetamol was highly efficient under these conditions, its mineralization was not likewise accomplished. GC-MS (gas chromatography-mass spectrometry...

  13. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    Science.gov (United States)

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  14. Metabolomics by Gas Chromatography-Mass Spectrometry: the combination of targeted and untargeted profiling

    Science.gov (United States)

    Fiehn, Oliver

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389

  15. Application of Pyrolysis - Gas Chromatography/Mass Spectrometry in Failure Analysis in the Automotive Industry

    OpenAIRE

    Kusch, Peter (Dr.)

    2015-01-01

    This book chapter describes application examples of gas chromatography/mass spectrometry and pyrolysis – gas chromatography/mass spectrometry in failure analysis for the identification of chemical materials like mineral oils and nitrile rubber gaskets. Furthermore, failure cases demanding identification of polymers/copolymers in fouling on the compressor wall of a car air conditioner and identification of fouling on the surface of a bearing race from the automotive industry are demonstr...

  16. Rapid determination of quetiapine in blood by gas chromatography-mass spectrometry. Application to post-mortem cases.

    Science.gov (United States)

    López-Guarnido, Olga; Tabernero, María Jesús; Hernández, Antonio F; Rodrigo, Lourdes; Bermejo, Ana M

    2014-10-01

    A simple, fast and sensitive method for the determination of quetiapine in human blood has been developed and validated. The method involved a basic liquid-liquid extraction procedure and subsequent analysis by gas chromatography-mass spectrometry, previous derivatization with bis(trimethylsilyl)-trifluoro-acetamide and chorotrimethylsilane (99 : 1). The methods of validation included linearity with a correlation coefficient > 0.99 over the range 0.02-1 µg ml(-1), intra- and interday precision (always < 12%) and accuracy (mean relative error always < 12%) to meet the bioanalytical acceptance criteria. The limit of detection was 0.005 µg ml(-1). The procedure was further applied to post mortems from the Institute of Legal Medicine, University of Santiago de Compostela. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Identification and differentiation of methcathinone analogs by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsujikawa, Kenji; Mikuma, Toshiyasu; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2013-08-01

    To overcome a number of challenges involved in analyzing methcathinone (MC) analogues, we performed gas chromatography-mass spectrometry (GC-MS) analysis, including sample preparation, of nine MC analogues - 4-methylmethcathinone, three positional isomers of fluoromethcathinones, 4-methoxymethcathinone, N-ethylcathinone, N,N-dimethylcathinone, buphedrone, and pentedrone. The MC analogues underwent dehydrogenation when the free bases were analyzed using splitless injection. Most of this thermal degradation was prevented using split injection. This indicated that a shorter residence time in the hot injector prevented decomposition. Uniquely, 2-fluoromethcathinone degraded to another product in a process that could not be prevented by the split injection. Replacing the liner with a new, clean one was also effective in preventing thermal degradation. Most of the analytes showed a substantial loss (>30%) when the free base solution in ethyl acetate was evaporated under a nitrogen stream. Adding a small amount of dimethylformamide as a solvent keeper had a noticeable effect, but it did not completely prevent the loss. Three positional isomers of fluoromethcathinones were separated with baseline resolution by heptafluorobutyrylation with a slow column heating rate (8 °C/min) using a non-polar DB-5 ms capillary column. These results will be useful for the forensic analysis of MC analogues in confiscated materials. Copyright © 2012 John Wiley & Sons, Ltd.

  18. A study on the separation and extraction of polycyclic aromatic hydrocarbons in water sample by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Lee, Won; Hong, Jee Eun; Park, Song Ja; Pyo, Hee Soo; Kim, In Hwan

    1998-01-01

    The separation and sample extraction methods of 19 polycyclic aromatic hydrocarbons (PAH S ) in water samples were investigated by gas chromatography/mass spectrometry (GC/MS) and some ex-traction methods involved liquid-liquid extraction, disk extraction and solid-phase extraction methods. The separation of 19 PAH s was possible by partial variation of oven temperature of GC/MS in temperature range 80∼310.deg.C. Extraction procedures of PAH s in water samples were somewhat modified and com-pared as extraction recoveries and the simplicity of methods. Extraction recoveries of PAH s were 71.3∼109.5% by liquid-liquid extraction method. By using disk extraction, good extraction recoveries (80.7∼94.9%) were obtained in case of C 1 8 disk extraction method by filtration. And extraction recoveries of PAH s by C 1 8 solid-phase were in the range of 51.8∼77.9%. Method detection limits (S/N=5) of 19 PAH s were in the range of 0.25∼6.25 ppb by liquid-liquid extraction and solid-phase extraction and 0.05∼1.25 ppb by disk extraction methods

  19. Chemometric profile of root extracts of Rhodiola imbricata Edgew. with hyphenated gas chromatography mass spectrometric technique.

    Directory of Open Access Journals (Sweden)

    Amol B Tayade

    Full Text Available Rhodiola imbricata Edgew. (Rose root or Arctic root or Golden root or Shrolo, belonging to the family Crassulaceae, is an important food crop and medicinal plant in the Indian trans-Himalayan cold desert. Chemometric profile of the n-hexane, chloroform, dichloroethane, ethyl acetate, methanol, and 60% ethanol root extracts of R. imbricata were performed by hyphenated gas chromatography mass spectrometry (GC/MS technique. GC/MS analysis was carried out using Thermo Finnigan PolarisQ Ion Trap GC/MS MS system comprising of an AS2000 liquid autosampler. Interpretation on mass spectrum of GC/MS was done using the NIST/EPA/NIH Mass Spectral Database, with NIST MS search program v.2.0g. Chemometric profile of root extracts revealed the presence of 63 phyto-chemotypes, among them, 1-pentacosanol; stigmast-5-en-3-ol, (3β,24S; 1-teracosanol; 1-henteracontanol; 17-pentatriacontene; 13-tetradecen-1-ol acetate; methyl tri-butyl ammonium chloride; bis(2-ethylhexyl phthalate; 7,8-dimethylbenzocyclooctene; ethyl linoleate; 3-methoxy-5-methylphenol; hexadecanoic acid; camphor; 1,3-dimethoxybenzene; thujone; 1,3-benzenediol, 5-pentadecyl; benzenemethanol, 3-hydroxy, 5-methoxy; cholest-4-ene-3,6-dione; dodecanoic acid, 3-hydroxy; octadecane, 1-chloro; ethanone, 1-(4-hydroxyphenyl; α-tocopherol; ascaridole; campesterol; 1-dotriacontane; heptadecane, 9-hexyl were found to be present in major amount. Eventually, in the present study we have found phytosterols, terpenoids, fatty acids, fatty acid esters, alkyl halides, phenols, alcohols, ethers, alkanes, and alkenes as the major group of phyto-chemotypes in the different root extracts of R. imbricata. All these compounds identified by GC/MS analysis were further investigated for their biological activities and it was found that they possess a diverse range of positive pharmacological actions. In future, isolation of individual phyto-chemotypes and subjecting them to biological activity will definitely prove fruitful

  20. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  1. Multivariate analytical figures of merit as a metric for evaluation of quantitative measurements using comprehensive two-dimensional gas chromatography-mass spectrometry.

    Science.gov (United States)

    Eftekhari, Ali; Parastar, Hadi

    2016-09-30

    The present contribution is devoted to develop multivariate analytical figures of merit (AFOMs) as a new metric for evaluation of quantitative measurements using comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). In this regard, new definition of sensitivity (SEN) is extended to GC×GC-MS data and then, other multivariate AFOMs including analytical SEN (γ), selectivity (SEL) and limit of detection (LOD) are calculated. Also, two frequently used second- and third-order calibration algorithms of multivariate curve resolution-alternating least squares (MCR-ALS) as representative of multi-set methods and parallel factor analysis (PARAFAC) as representative of multi-way methods are discussed to exploit pure component profiles and to calculate multivariate AFOMs. Different GC×GC-MS data sets with different number of components along with various levels of artifacts are simulated and analyzed. Noise, elution time shifts in both chromatographic dimensions, peak overlap and interferences are considered as the main artifacts in this work. Additionally, a new strategy is developed to estimate the noise level using variance-covariance matrix of residuals which is very important to calculate multivariate AFOMs. Finally, determination of polycyclic aromatic hydrocarbons (PAHs) in aromatic fraction of heavy fuel oil (HFO) analyzed by GC×GC-MS is considered as real case to confirm applicability of the proposed metric in real samples. It should be pointed out that the proposed strategy in this work can be used for other types of comprehensive two-dimensional chromatographic (CTDC) techniques like comprehensive two dimensional liquid chromatography (LC×LC). Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Triacylglycerol profiling of microalgae strains for biofuel feedstock by liquid chromatography-high-resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    MacDougall, Karen M.; McNichol, Jesse; McGinn, Patrick J.; O' Leary, Stephen J.B.; Melanson, Jeremy E. [Institute for Marine Biosciences, National Research Council of Canada, Halifax, NS (Canada)

    2011-11-15

    Biofuels from photosynthetic microalgae are quickly gaining interest as a viable carbon-neutral energy source. Typically, characterization of algal feedstock involves breaking down triacylglycerols (TAG) and other intact lipids, followed by derivatization of the fatty acids to fatty acid methyl esters prior to analysis by gas chromatography (GC). However, knowledge of the intact lipid profile could offer significant advantages for discovery stage biofuel research such as the selection of an algal strain or the optimization of growth and extraction conditions. Herein, lipid extracts from microalgae were directly analyzed by ultra-high pressure liquid chromatography-mass spectrometry (UHPLC-MS) using a benchtop Orbitrap mass spectrometer. Phospholipids, glycolipids, and TAGs were analyzed in the same chromatographic run, using a combination of accurate mass and diagnostic fragment ions for identification. Using this approach, greater than 100 unique TAGs were identified over the six algal strains studied and TAG profiles were obtained to assess their potential for biofuel applications. Under the growth conditions employed, Botryococcus braunii and Scenedesmus obliquus yielded the most comprehensive TAG profile with a high abundance of TAGs containing oleic acid. (orig.)

  3. Profiling of volatile organic compounds produced by clinical Aspergillus isolates using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Gerritsen, M G; Brinkman, P; Escobar Salazar, Natalia; Bos, L D; de Heer, K; Meijer, M; Janssen, H-G; de Cock, H; Wösten, H A B; Visser, C.E.; van Oers, M H J; Sterk, P J

    Volatile organic compounds (VOCs) in exhaled breath may identify the presence of invasive pulmonary aspergillosis. We aimed to detect VOC profiles emitted by in vitro cultured, clinical Aspergillus isolates using gas chromatography-mass spectrometry (GC-MS). Three clinical Aspergillus isolates and a

  4. Gas chromatography-mass spectrometry (GC-MS) analysis of extractives of naturally durable wood

    Science.gov (United States)

    G.T. Kirker; A.B. Blodgett; S.T. Lebow; C.A. Clausen

    2011-01-01

    A preliminary study to evaluate naturally durable wood species in an above ground field trial using Gas Chromatography-Mass Spectrometry (GC-MS) detected differences in fatty acid extractives between species and within the same species over time. Fatty acids were extracted with chloroform: methanol mixture then methylated with sodium methoxide and fractionated using...

  5. Ion counting method and it's operational characteristics in gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Fujii, Toshihiro

    1976-01-01

    Ion counting method with continuous channel electron multiplier which affords the direct detection of very small ion currents and it's operational characteristics were studied in gas chromatography-mass spectrometry. Then this method was applied to the single ion detection technique of GC-MS. A detection limit was measured, using various standard samples of low level concentration. (auth.)

  6. Gas Chromatography/mass Spectrometry Analysis of Exhaled Leukotrienes in Asthmatic Patients

    Czech Academy of Sciences Publication Activity Database

    Čáp, P.; Chládek, J.; Pehal, F.; Malý, Marek; Petrů, V.; Barnes, P.J.; Montuschi, P.

    2004-01-01

    Roč. 59, č. 6 (2004), s. 465-470 ISSN 0040-6376 Source of funding: V - iné verejné zdroje Keywords : asthma * breath condensate * gas chromatography/mass spectrometry * leukotrienes Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 5.040, year: 2004

  7. Profiling of volatile organic compounds produced by clinical Aspergillus isolates using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Gerritsen, M. G.; Brinkman, P.; Escobar, N.; Bos, L. D.; de Heer, K.; Meijer, M.; Janssen, H.-G.; de Cock, H.; Wösten, H. A. B.; Visser, C. E.; van Oers, M. H. J.; Sterk, P. J.

    2018-01-01

    Volatile organic compounds (VOCs) in exhaled breath may identify the presence of invasive pulmonary aspergillosis. We aimed to detect VOC profiles emitted by in vitro cultured, clinical Aspergillus isolates using gas chromatography-mass spectrometry (GC-MS). Three clinical Aspergillus isolates and a

  8. Gas Chromatography-Mass Spectroscopic (GC-MS) Analysis of n ...

    African Journals Online (AJOL)

    1Department of Pharmacognosy and Phytotherapy, 2Department of Pharmaceutics and Pharmaceutical Technology, University of Port Harcourt, Nigeria ... tuber-regium (synonym Pleurotus tuber regium) using gas chromatography-mass spectroscopic (GC- ... Department of Plant Science and Biotechnology,. University of ...

  9. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  10. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  11. Fabrication of thin TEM sample of ionic liquid for high-resolution ELNES measurements

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Tomohiro, E-mail: tomo-m@iis.u-tokyo.ac.jp; Mizoguchi, Teruyasu, E-mail: teru@iis.u-tokyo.ac.jp

    2017-07-15

    Investigation of the local structure, ionic and molecular behavior, and chemical reactions at high spatial resolutions in liquids has become increasingly important. Improvements in these areas help to develop efficient batteries and improve organic syntheses. Transmission electron microscopy (TEM) and scanning-TEM (STEM) have excellent spatial resolution, and the electron energy-loss near edge structure (ELNES) measured by the accompanied electron energy-loss spectroscopy (EELS) is effective to analyze the liquid local structure owing to reflecting the electronic density of states. In this study, we fabricate a liquid-layer-only sample with thickness of single to tens nanometers using an ionic liquid. Because the liquid film has a thickness much less than the inelastic mean free path (IMFP) of the electron beam, the fine structure of the C-K edge electron energy loss near edge structure (ELNES) can be measured with sufficient resolution to allow meaningful analysis. The ELNES spectrum from the thin liquid film has been interpreted using first principles ELNES calculations. - Highlights: • A fabrication method of thin liquid film samples for STEM-EELS observations is proposed. • The thickness of the fabricated thin liquid film is about 10 nm. • An ELNES is measured from the thin liquid with a high energy resolution. • The peaks of the ELNES are interpreted using first principles calculations.

  12. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    Science.gov (United States)

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  13. [Confirming Indicators of Qualitative Results by Chromatography-mass Spectrometry in Biological Samples].

    Science.gov (United States)

    Liu, S D; Zhang, D M; Zhang, W; Zhang, W F

    2017-04-01

    Because of the exist of complex matrix, the confirming indicators of qualitative results for toxic substances in biological samples by chromatography-mass spectrometry are different from that in non-biological samples. Even in biological samples, the confirming indicators are different in various application areas. This paper reviews the similarities and differences of confirming indicators for the analyte in biological samples by chromatography-mass spectrometry in the field of forensic toxicological analysis and other application areas. These confirming indicators include retention time (RT), relative retention time (RRT), signal to noise (S/N), characteristic ions, relative abundance of characteristic ions, parent ion-daughter ion pair and abundance ratio of ion pair, etc. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  14. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations

  15. Study on aroma components of osmanthus by absorption wire gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Feng Janyue; Zhao Jing; Huang Qiaoqiao; Feng Lianmei

    2001-01-01

    The aroma components of fresh osmanthus are captured by absorption wires. The fragrant components absorbed in the wires are desorbed immediately at 358 degree C in Curie-point pyrolyzed, and then led into GC/MS to analyze. As a result, 41 aroma compounds such as β-linalool, linalooloxide, β-ocimene etc. in osmanthus are detected qualitatively by gas chromatography/mass spectrometry. This method can be used to analyze the change of aroma compounds of fresh flowers while blossoming

  16. Demonstration of conjugated dopamine in monkey CSF by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Elchisak, M A; Powers, K H; Ebert, M H

    1982-09-01

    A method for measuring unconjugated and conjugated dopamine in body tissues and fluids is described. Conjugated dopamine was hydrolyzed in acid to unconjugated dopamine, separated from the sample matrix by alumina chromatography, and assayed by gas chromatography-mass spectrometry. Conjugated dopamine was detected in greater concentrations than unconjugated dopamine in CSF taken from lateral ventricle or thecal sac of the Rhesus monkey. Haloperidol administration did not increase the levels of conjugated dopamine in lumbar CSF.

  17. Measurement parameter selection for quantitative isotope dilution gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Colby, B.N.; Rosecrance, A.E.; Colby, M.E.

    1981-01-01

    By use of the two-isotope model of isotope dilution, selection criteria were developed for identifying optimum m/z's for quantitation of compounds by gas chromatography/mass spectrometry. In addition, it was possible to predict the optimum ratio of naturally abundant to labeled compound and to identify appropriate data reduction methods. The validity of these predictions was confirmed by using experimental GC/MS data for several organic compounds

  18. Resolution 49/013. Is adequate the quality control of liquid fuels Regulation, approved by Resolution of the URSEA 150/2008

    International Nuclear Information System (INIS)

    2013-01-01

    This Resolution is about the need to adapt the quality control regulation of liquid carburant approved by Resolution of the URSEA N. 150/2008. ANCAP has informed to URSEA the incorporation and reformularization of alcohol carburant in the gasoline

  19. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying; Reardon, Patrick N.; Renslow, Ryan S.; Khbeis, Michael; Irish, Duane; Mueller, Karl T.

    2017-01-01

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

  20. An improved, automated whole air sampler and gas chromatography mass spectrometry analysis system for volatile organic compounds in the atmosphere

    Science.gov (United States)

    Lerner, Brian M.; Gilman, Jessica B.; Aikin, Kenneth C.; Atlas, Elliot L.; Goldan, Paul D.; Graus, Martin; Hendershot, Roger; Isaacman-VanWertz, Gabriel A.; Koss, Abigail; Kuster, William C.; Lueb, Richard A.; McLaughlin, Richard J.; Peischl, Jeff; Sueper, Donna; Ryerson, Thomas B.; Tokarek, Travis W.; Warneke, Carsten; Yuan, Bin; de Gouw, Joost A.

    2017-01-01

    Volatile organic compounds were quantified during two aircraft-based field campaigns using highly automated, whole air samplers with expedited post-flight analysis via a new custom-built, field-deployable gas chromatography-mass spectrometry instrument. During flight, air samples were pressurized with a stainless steel bellows compressor into electropolished stainless steel canisters. The air samples were analyzed using a novel gas chromatograph system designed specifically for field use which eliminates the need for liquid nitrogen. Instead, a Stirling cooler is used for cryogenic sample pre-concentration at temperatures as low as -165 °C. The analysis system was fully automated on a 20 min cycle to allow for unattended processing of an entire flight of 72 sample canisters within 30 h, thereby reducing typical sample residence times in the canisters to less than 3 days. The new analytical system is capable of quantifying a wide suite of C2 to C10 organic compounds at part-per-trillion sensitivity. This paper describes the sampling and analysis systems, along with the data analysis procedures which include a new peak-fitting software package for rapid chromatographic data reduction. Instrument sensitivities, uncertainties and system artifacts are presented for 35 trace gas species in canister samples. Comparisons of reported mixing ratios from each field campaign with measurements from other instruments are also presented.

  1. Determination of major boswellic acids in plasma by high-pressure liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Gerbeth, Kathleen; Meins, Juergen; Kirste, Simon; Momm, Felix; Schubert-Zsilavecz, Manfred; Abdel-Tawab, Mona

    2011-12-15

    Until now, dexamethasone is the medication of choice to reduce peritumoral edema associated with primary and secondary brain tumors. Because of the severe side effects accompanying such a treatment the interest in alternative agents that may be co-administered with glucocorticoids and help to reduce the required dose is constantly increasing. Boswellia serrata gum resin extracts (BSE), which have been designated an orphan drug status by the European Medicines Agency (EMA) in 2002 for the treatment of peritumoral edema, may represent a promising supplemental herbal remedy. However, clinical studies on the effect of BSE on brain edema as well as analyzes of serum levels are very scarce. Based on that background a prospective, placebo controlled, and double blind clinical pilot trial was conducted on 14 patients applying for the first time a high dose of 4200 mg BSE per day and 13 patients receiving placebo. For monitoring the serum levels of all major boswellic acids (BAs) a highly sensitive HPLC-MS method has been developed that allows the determination of KBA and AKBA from 5.0 ng/ml to 3000 ng/ml and of αBA, βBA, AαBA and AβBA from 0.5 ng/ml to 12,000 ng/ml. It is the first validated method that covers such a wide concentration range, which makes it suitable to be used as standard method in clinical trials as it compensates for the great pharmacokinetic variability in the plasma levels of BAs observed in clinical practice. Average steady concentrations (ng/ml) in the range of 6.4-247.5 for KBA, 0-15.5 for AKBA, 36.7-4830.1 for αBA, 87.0-11948.5 for βBA, 73.4-2985.8 for AαBA and 131.4-6131.3 for AβBA were determined in the verum group. The here quantified steady state levels suggest βBA to be a possible candidate for the anti-inflammatory and anti-edemateous effects of BSE. In general, the serum level analysis underlines the promising clinical results of BSE on cerebral edema. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. A harmonized immunoassay with liquid chromatography-mass spectrometry analysis in egg allergen determination.

    Science.gov (United States)

    Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro

    2018-01-01

    Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.

  3. Atmospheric pressure photoionisation : An ionization method for liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Robb, DB; Covey, TR; Bruins, AP

    2000-01-01

    Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from

  4. Determination of ghrelin analogs in plasma samples by liquid chromatography-mass spectrometry using monolithic column

    Czech Academy of Sciences Publication Activity Database

    Zemenová, Jana; Železná, Blanka; Maletínská, Lenka; Sýkora, D.

    2016-01-01

    Roč. 22, Suppl S2 (2016), S105 ISSN 1075-2617. [European Peptide Symposium /34./ and International Peptide Symposium /8./. 04.09.2016-09.09.2016, Leipzig] Institutional support: RVO:61388963 Keywords : ghrelin * LC-MS Subject RIV: CE - Biochemistry

  5. Analysis of Sulfonylurea Herbicides at PPT Levels by Liquid Chromatography-Mass Spectrometry

    DEFF Research Database (Denmark)

    Bossi, R.; Spliid, N. H.; Streibig, J. C.

    1996-01-01

    Proceedings of the X Symposium Pesticide Chemistry, September 30 - October 2, 1996, Castelnuovo Fogliani, Piacenza, Italia......Proceedings of the X Symposium Pesticide Chemistry, September 30 - October 2, 1996, Castelnuovo Fogliani, Piacenza, Italia...

  6. Analysis of sorghum wax and carnauba wax by reversed phase liquid chromatography mass spectrometry

    Science.gov (United States)

    Sorghum is a genus in the grass family, which is used for both grain and forage production throughout the world. In the United States, sorghum grain is predominantly used as livestock feed, and in ethanol production. In recent years however, sorghum grain has been investigated for other industrial a...

  7. Molecular species composition of plant cardiolipin determined by liquid chromatography mass spectrometry

    Science.gov (United States)

    Zhou, Yonghong; Peisker, Helga

    2016-01-01

    Cardiolipin (CL), an anionic phospholipid of the inner mitochondrial membrane, provides essential functions for stabilizing respiratory complexes and is involved in mitochondrial morphogenesis and programmed cell death in animals. The role of CL and its metabolism in plants are less well understood. The measurement of CL in plants, including its molecular species composition, is hampered by the fact that CL is of extremely low abundance, and that plants contain large amounts of interfering compounds including galactolipids, neutral lipids, and pigments. We used solid phase extraction by anion exchange chromatography to purify CL from crude plant lipid extracts. LC/MS was used to determine the content and molecular species composition of CL. Thus, up to 23 different molecular species of CL were detected in different plant species, including Arabidopsis, mung bean, spinach, barley, and tobacco. Similar to animals, plant CL is dominated by highly unsaturated species, mostly containing linoleic and linolenic acid. During phosphate deprivation or exposure to an extended dark period, the amount of CL decreased in Arabidopsis, accompanied with an increased degree in unsaturation. The mechanism of CL remodeling during stress, and the function of highly unsaturated CL molecular species, remains to be defined. PMID:27179363

  8. Dried blood spot assay for the quantification of phenytoin using Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Villanelli, Fabio; Giocaliere, Elisa; Malvagia, Sabrina; Rosati, Anna; Forni, Giulia; Funghini, Silvia; Shokry, Engy; Ombrone, Daniela; Della Bona, Maria Luisa; Guerrini, Renzo; la Marca, Giancarlo

    2015-02-02

    Phenytoin (PHT) is one of the most commonly used anticonvulsant drugs for the treatment of epilepsy and bipolar disorders. The large amount of plasma required by conventional methods for drug quantification makes mass spectrometry combined with dried blood spot (DBS) sampling crucial for pediatric patients where therapeutic drug monitoring or pharmacokinetic studies may be difficult to realize. DBS represents a new convenient sampling support requiring minimally invasive blood drawing and providing long-term stability of samples and less expensive shipment and storage. The aim of this study was to develop a LC-MS/MS method for the quantification of PHT on DBS. This analytical method was validated and gave good linearity (r(2)=0.999) in the range of 0-100mg/l. LOQ and LOD were 1.0mg/l and 0.3mg/l, respectively. The drug extraction from paper was performed in a few minutes using a mixture composed of organic solvent for 80%. The recovery ranged from 85 to 90%; PHT in DBS showed to be stable at different storage temperatures for one month. A good correlation was also obtained between PHT plasma and DBS concentrations. This method is both precise and accurate and appears to be particularly suitable to monitor treatment with a simple and convenient sample collection procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Detection of chloramphenicol residue in bovine meat using Liquid Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Widiastuti R

    2014-03-01

    Full Text Available Chloramphenicol (CAP is a broad spectrum antibiotic that has been banned in many countries due to its serius side effect to human. Detection of CAP residue in food has been determined to a minimum required performance limit (MRPL of 0.3 ng/g. The purpose of this research was to conduct the analysis of CAP residue in bovine meat by using LCMS and to study the presence of CAP residue in marketed bovine meat samples. LC separation was done on a Shimpack column C18 with ammonium acetate 10 mM/water as mobile phase, and ESI-MS analysis in negative ion mode. The coefficient of determination, R2 = 0.9981 at concentration of 0.125, 0.25, 0.63, 1,00 and 2.00 ng/g. Recovery at three fortification levels (0.25, 0.50 and 1.00 ng/g was in the range 77.5, 97.3 and 83.4%. The decision limit and the detection capability were 0.15 ng/g and 0.17 ng/g respectively. Analysis results of 52 marketed samples showed that CAP residue were detected in 9 samples in the concentration range of 0.14 to 2.70 ng/g and 6 among those positive samples were above the MRPL value. Therefore, it is important to increase the awareness and also to monitor regularly CAP residues in food originated from animal to provide safe food for the consumers.

  10. Quantification of Almond Skin Polyphenols by Liquid Chromatography-Mass Spectrometry

    OpenAIRE

    Bolling, Bradley W.; Dolnikowski, Gregory; Blumberg, Jeffrey B.; Oliver Chen, C.Y.

    2009-01-01

    Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic acids from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-day relative standard deviation (RSD) of standard curve slopes ranged from 13% to 25% of the mean. On column (OC) limits of detection (LOD) for polyphenols ranged from 0.013 to 1.4 pmol, and flavonoid gly...

  11. Liquid Chromatography-Mass Spectrometry Interface for Detection of Extraterrestrial Organics

    Science.gov (United States)

    Southard, Adrian E.; Getty, Stephanie A.; Balvin, Manuel; Cook, Jamie E.; Espiritu, Ana Mellina; Kotecki, Carl; Towner, Deborah W.; Dworkin, J. P.; Glavin, Daniel P.; Mahaffy, Paul R.; hide

    2014-01-01

    The OASIS (Organics Analyzer for Sampling Icy surfaces) microchip enables electrospray or thermospray of analyte for subsequent analysis by the OASIS time-of-flight mass spectrometer. Electrospray of buffer solution containing the nucleobase adenine was performed using the microchip and detected by a commercial time-of-flight mass spectrometer. Future testing of thermospray and electrospray capability will be performed using a test fixture and vacuum chamber developed especially for optimization of ion spray at atmosphere and in low pressure environments.

  12. Analysis of citalopram and desmethylcitalopram in postmortem fluids and tissues using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    2011-10-01

    "Citalopram is a selective serotonin reuptake inhibitor that is a commonly prescribed drug for the treatment of : depression, obsessive-compulsive disorder, panic disorder, anxiety disorder, and post-traumatic stress disorder. : While the use of cita...

  13. Simulation of the oxidative metabolism of diclofenac by electrochemistry/(liquid chromatography/)mass spectrometry.

    Science.gov (United States)

    Faber, Helene; Melles, Daniel; Brauckmann, Christine; Wehe, Christoph Alexander; Wentker, Kristina; Karst, Uwe

    2012-04-01

    Diclofenac is a frequently prescribed drug for rheumatic diseases and muscle pain. In rare cases, it may be associated with a severe hepatotoxicity. In literature, it is discussed whether this toxicity is related to the oxidative phase I metabolism, resulting in electrophilic quinone imines, which can subsequently react with nucleophiles present in the liver in form of glutathione or proteins. In this work, electrochemistry coupled to mass spectrometry is used as a tool for the simulation of the oxidative pathway of diclofenac. Using this purely instrumental approach, diclofenac was oxidized in a thin layer cell equipped with a boron doped diamond working electrode. Sum formulae of generated oxidation products were calculated based on accurate mass measurements with deviations below 2 ppm. Quinone imines from diclofenac were detected using this approach. It could be shown for the first time that these quinone imines do not react with glutathione exclusively but also with larger molecules such as the model protein β-lactoglobulin A. A tryptic digest of the generated drug-protein adduct confirms that the protein is modified at the only free thiol-containing peptide. This simple and purely instrumental set-up offers the possibility of generating reactive metabolites of diclofenac and to assess their reactivity rapidly and easily.

  14. Improvements on enzymatic hydrolysis of human hair for illicit drug determination by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Míguez-Framil, Martha; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Pilar; López, Patricia; Tabernero, María Jesús; Bermejo, Ana María

    2007-11-15

    The use of ultrasound energy for accelerating the pronase E enzymatic hydrolysis of human hair for extracting illicit drugs has been novelty tested. The enzymatic extracts obtained after 30 min of sonication in an ultrasonic water bath were subjected to an optimized solid-phase extraction process, which involved a solution of 2.0% (v/v) acetic acid in methanol as eluting solution and concentration by N2 stream evaporation. A gas chromatography/mass spectrometry method was used to separate and determine cocaine, benzoylecgonine, codeine, morphine, and 6-monoacethylmorphine in 20 min. Variables affecting ultrasound-assisted pronase E hydrolysis such as hydrolysis temperature, hydrolysis time, enzyme concentration, catalyzer (1,4-dithiothreitol) concentration, ionic strength, pH, and ultrasound frequency were simultaneously evaluated by a Plackett-Burman design 2(8) PBD of resolution III. The most statistically significant variables were ionic strength and pH, which means that analyte extraction is mainly attributed to pronase E activity. The optimization or evaluation of all the factors has led to an accelerated pronase E hydrolysis of human hair, which can be completed in 30 min. Results have been found to be statistically similar to those obtained with conventional pronase E hydrolysis. The accelerated method was finally applied to several human hair samples from multidrug abusers.

  15. High Resolution NMR Studies of Encapsulated Proteins In Liquid Ethane

    Science.gov (United States)

    Peterson, Ronald W.; Lefebvre, Brian G.; Wand, A. Joshua

    2005-01-01

    Many of the difficulties presented by large, aggregation-prone, and membrane proteins to modern solution NMR spectroscopy can be alleviated by actively seeking to increase the effective rate of molecular reorientation. An emerging approach involves encapsulating the protein of interest within the protective shell of a reverse micelle, and dissolving the resulting particle in a low viscosity fluid, such as the short chain alkanes. Here we present the encapsulation of proteins with high structural fidelity within reverse micelles dissolved in liquid ethane. The addition of appropriate co-surfactants can significantly reduce the pressure required for successful encapsulation. At these reduced pressures, the viscosity of the ethane solution is low enough to provide sufficiently rapid molecular reorientation to significantly lengthen the spin-spin NMR relaxation times of the encapsulated protein. PMID:16028922

  16. Gas chromatography/mass spectrometry characterization of historical varnishes of ancient Italian lutes and violin.

    Science.gov (United States)

    Echard, J P; Benoit, C; Peris-Vicente, J; Malecki, V; Gimeno-Adelantado, J V; Vaiedelich, S

    2007-02-12

    The organic constituents of historical vanishes from two ancient Italian lutes and a Stradivari violin, kept in the Musée de la musique in Paris, have been characterized using gas chromatography-mass spectrometry. Results have been compared with the chromatograms and mass spectra of recent as well as old naturally aged reference materials. The three historical varnishes analyzed have been shown to be oil varnishes, probably mixtures of linseed oil with resins. Identification of diterpenoids and triterpenoids compounds, and of the resins that may have been ingredients of the varnishes, are discussed in this paper.

  17. Comparison of photoacoustic radiometry to gas chromatography/mass spectrometry methods for monitoring chlorinated hydrocarbons

    International Nuclear Information System (INIS)

    Sollid, J.E.; Trujillo, V.L.; Limback, S.P.; Woloshun, K.A.

    1996-01-01

    A comparison of two methods of gas chromatography mass spectrometry (GCMS) and a nondispersive infrared technique, photoacoustic radiometry (PAR), is presented in the context of field monitoring a disposal site. First is presented an historical account describing the site and early monitoring to provide an overview. The intent and nature of the monitoring program changed when it was proposed to expand the Radiological Waste Site close to the Hazardous Waste Site. Both the sampling methods and analysis techniques were refined in the course of this exercise

  18. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  19. Characterization of Volatile Compounds from Ethnic Agave Alcoholic Beverages by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Pilar Escalante-Minakata

    2008-01-01

    Full Text Available Ethnic Agave alcoholic beverages such as raicilla, sisal, tequila, mezcal, bacanora, sotol and pulque have been analyzed by gas chromatography and headspace solid-phase microextraction- gas chromatography-mass spectrometry (HS-SPME-GC-MS. There were 105 compounds identified, eleven were classified as major compounds and the others were classified as minor compounds. Seventeen minor compounds could be used as authenticity markers since they were beverage specific. Cluster analysis (CA showed that Agave alcoholic beverages could be distinguished by multivariate analysis of major compounds; however, the analysis of minor compounds provided a better fingerprinting.

  20. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    Gutierrez Gaiten, Yamilet Irene; Miranda Martinez, Migdalia; Bello Alarcon, Adonis

    2011-01-01

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  1. Current use of high-resolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control.

    Science.gov (United States)

    Ojanperä, Ilkka; Kolmonen, Marjo; Pelander, Anna

    2012-05-01

    Clinical and forensic toxicology and doping control deal with hundreds or thousands of drugs that may cause poisoning or are abused, are illicit, or are prohibited in sports. Rapid and reliable screening for all these compounds of different chemical and pharmaceutical nature, preferably in a single analytical method, is a substantial effort for analytical toxicologists. Combined chromatography-mass spectrometry techniques with standardised reference libraries have been most commonly used for the purpose. In the last ten years, the focus has shifted from gas chromatography-mass spectrometry to liquid chromatography-mass spectrometry, because of progress in instrument technology and partly because of the polarity and low volatility of many new relevant substances. High-resolution mass spectrometry (HRMS), which enables accurate mass measurement at high resolving power, has recently evolved to the stage that is rapidly causing a shift from unit-resolution, quadrupole-dominated instrumentation. The main HRMS techniques today are time-of-flight mass spectrometry and Orbitrap Fourier-transform mass spectrometry. Both techniques enable a range of different drug-screening strategies that essentially rely on measuring a compound's or a fragment's mass with sufficiently high accuracy that its elemental composition can be determined directly. Accurate mass and isotopic pattern acts as a filter for confirming the identity of a compound or even identification of an unknown. High mass resolution is essential for improving confidence in accurate mass results in the analysis of complex biological samples. This review discusses recent applications of HRMS in analytical toxicology.

  2. Stable carbon isotopic composition of gasolines determined by isotope ratio monitoring gas chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Smallwood, B.J.; Philp, R.P.; Allen, J.D. [University of Oklahoma, Norman, OK (United States). School of Geology and Geophysics

    2002-07-01

    A large number of underground gasoline storage facilities in the United States continuously leak gasoline into the subsurface, which makes gasoline a major groundwater contaminant. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) are used currently to characterize contaminated groundwater and soils. Correlations of contaminants with suspected source(s) are extremely difficult by these techniques because many gasolines have similar hydrocarbon distributions. The present study applied the technique of isotope ratio monitoring gas chromatography-mass spectrometry (irmGC-MS) to 19 gasoline samples from different areas of the USA. This allows a much better correlation of gasoline contaminants to source. Data obtained indicate a wide range of {sup {delta}}{sup 13}C values for 16 ubiquitous compounds in the gasolines. The majority of samples could be distinguished from each other on the basis of {sup {delta}}{sup 13}C hydrocarbon composition. The oxygenated additive methyl tertiary butyl ether (MTBE) was present in ten of the gasolines analyzed, and had a relatively narrow range of {sup {delta}}{sup 13}C values (-30.4 to -28.3 per mille). Preliminary investigations were also made to determine the extent of carbon isotopic fractionation after simple water washing and evaporation experiments. Results indicate that the majority of compounds did not undergo significant carbon isotopic fractionation as a result of these processes. (author)

  3. Resolution in QCM Sensors for the Viscosity and Density of Liquids: Application to Lead Acid Batteries

    Directory of Open Access Journals (Sweden)

    Jorge Marcos-Acevedo

    2012-08-01

    Full Text Available In battery applications, particularly in automobiles, submarines and remote communications, the state of charge (SoC is needed in order to manage batteries efficiently. The most widely used physical parameter for this is electrolyte density. However, there is greater dependency between electrolyte viscosity and SoC than that seen for density and SoC. This paper presents a Quartz Crystal Microbalance (QCM sensor for electrolyte density-viscosity product measurements in lead acid batteries. The sensor is calibrated in H2SO4 solutions in the battery electrolyte range to obtain sensitivity, noise and resolution. Also, real-time tests of charge and discharge are conducted placing the quartz crystal inside the battery. At the same time, the present theoretical “resolution limit” to measure the square root of the density-viscosity product ( of a liquid medium or best resolution achievable with a QCM oscillator is determined. Findings show that the resolution limit only depends on the characteristics of the liquid to be studied and not on frequency. The QCM resolution limit for  measurements worsens when the density-viscosity product of the liquid is increased, but it cannot be improved by elevating the work frequency.

  4. Resolution in QCM sensors for the viscosity and density of liquids: application to lead acid batteries.

    Science.gov (United States)

    Cao-Paz, Ana María; Rodríguez-Pardo, Loreto; Fariña, José; Marcos-Acevedo, Jorge

    2012-01-01

    In battery applications, particularly in automobiles, submarines and remote communications, the state of charge (SoC) is needed in order to manage batteries efficiently. The most widely used physical parameter for this is electrolyte density. However, there is greater dependency between electrolyte viscosity and SoC than that seen for density and SoC. This paper presents a Quartz Crystal Microbalance (QCM) sensor for electrolyte density-viscosity product measurements in lead acid batteries. The sensor is calibrated in H(2)SO(4) solutions in the battery electrolyte range to obtain sensitivity, noise and resolution. Also, real-time tests of charge and discharge are conducted placing the quartz crystal inside the battery. At the same time, the present theoretical "resolution limit" to measure the square root of the density-viscosity product [Formula: see text] of a liquid medium or best resolution achievable with a QCM oscillator is determined. Findings show that the resolution limit only depends on the characteristics of the liquid to be studied and not on frequency. The QCM resolution limit for [Formula: see text] measurements worsens when the density-viscosity product of the liquid is increased, but it cannot be improved by elevating the work frequency.

  5. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSD<5%), analytical recovery (96.2-98.0%), and sensitivity (limit of detection=0.009 and 0.004 μg mL(-1) for arbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.).

  6. Chromatography mass spectrometry and its use in identification in the radiolysis products of polycyclic aromatic hydrocarbons and organic compounds

    International Nuclear Information System (INIS)

    Ibadov, N.A.; Suleymanov, B.A.

    2010-01-01

    Full text : Increased attention to the environment is the result of dramatically increased human activity, which in turn is caused by the rapid growth of population of the planet. Extremely powerful tool for control of pollution of different environmental objects - Chromatographic methods to analyze complex mixtures of components. This work is devoted to methods of gas chromatography - mass - spectroscopy and its use in identifying the pollutants of natural environments. Devices that allow obtaining the mass spectra are called mass spectrometers. Sensitivity of gas chromatography-mass spectrometry (typically 10-6-10-9 g) determined by the sensitivity of the mass spectrometer detector. Its essence lies in the fact that the recording of chromatograms is not the full ion current and the most characteristic ions of the substance. With varying degrees of probability in the water identified over 100 individual organic compounds, including PHs. The method of gas chromatography-mass spectrometry identified compounds in natural waters, soils, soil and sediments.

  7. Pyrolysis-gas chromatography-mass spectrometry of isolated, synthetic and degraded lignins

    Energy Technology Data Exchange (ETDEWEB)

    Saiz-Jimenez, C.; De Leeuw, J.W.

    1984-01-01

    Curie-point pyrolysis-gas chromatography-mass spectrometry was applied to study the chemical structure of sound and fungus degraded, industrial and synthetic lignins. Pyrolysis products reflected in some detail the structural units present in the lignin polymer. Thus, sound spruce lignin yielded trans-isoeugenol coniferaldehyde and trans-coniferyl alcohol as major pyrolysis products. Biodegraded lignin yielded oxidized units, including vanillin, acetoguaiacone, methyl vanillate, propioguaiacone, vanilloyl methyl ketone and vanillic acid as major products. Kraft lignin also showed evidence of oxidation, although not as much as the biodegraded lignin. Major products from this industrial lignin were guaiacol, methylguaiacol, vinylguaiacol and homovanillic acid. Results indicated that synthetic lignin duplicates fairly well the structure of natural lignin. However, coniferylaldehyde and trans-coniferyl alcohol were the dominant products only from the synthetic lignin, indicating the presence of large amounts of coniferyl alcohol and coniferylaldehyde end groups. 21 references.

  8. Determination of Chlorpyrifos in Human Blood by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xinhua Dai

    2017-01-01

    Full Text Available Gas chromatography-mass spectrometry method was developed for the qualitative and quantitative analyses of chlorpyrifos in human blood samples. The chlorpyrifos and parathion (internal standard in human blood were extracted with a mixed solvent of hexane and acetonitrile. Chlorpyrifos was well separated from the internal standard. The linear range of chlorpyrifos was 0.01–2 μg/ml in blood. The limit of detection and limit of quantification were estimated at 0.002 and 0.01 μg/ml, respectively. The inter- and intra-day precisions, accuracy, and recovery were assessed to verify this method. The results showed that the developed method is rapid, sensitive, and reliable. It is suitable for the determination of chlorpyrifos in forensic toxicological analysis and clinical diagnosis.

  9. Principles and applications of a research-oriented gas chromatography-mass spectrometry data system

    International Nuclear Information System (INIS)

    Campana, J.E.; Risby, T.H.; Jurs, P.C.

    1979-01-01

    A research-oriented gas chromatography-mass spectrometry data system for a quadrupole mass spectrometer has been developed based on a centrally located departmental computer facility. An overview of the hardware and software system is presented, emphasizing the important aspects of on-line computer data acquisition and control and the design philosophy used in the development of the system. The application of the system is demonstrated by the g.c.-m.s. analysis of a mixture of four transition metal β-diketonates (Al, Cr, Rh, and Ru tris-1,1,1-trifluoro-pentane-2,4-dionate). This anaysis involved vacuum gas chromatography with a support-coated open tubular column and detection of the eluent by chemical ionization mass spectrometry. The results demonstrate the data system capabilities and indicate the utility of the combined methodologies. (Auth.)

  10. Gas chromatography-mass spectrometry evidence for several endogenous auxins in pea seedling organs.

    Science.gov (United States)

    Schneider, E A; Kazakoff, C W; Wightman, F

    1985-08-01

    Qualitative analysis by gas chromatography-mass spectrometry (GC-MS) of the auxins present in the root, cotyledons and epicotyl of 3-dold etiolated pea (Pisum sativum L., cv. Alaska) seedlings has shown that all three organs contain phenylacetic acid (PAA), 3-indoleacetic acid (IAA) and 4-chloro-3-indoleacetic acid (4Cl-IAA). In addition, 3-indolepropionic acid (IPA) was present in the root and 3-indolebutyric acid (IBA) was detected in both root and epicotyl. Phenylacetic acid, IAA and IPA were measured quantitatively in the three organs by GC-MS-single ion monitoring, using deuterated internal standards. Levels of IAA were found to range from 13 to 115 pmol g(-1) FW, while amounts of PAA were considerably higher (347-451 pmol g(-1) FW) and the level of IPA was quite low (5 pmol g(-1) FW). On a molar basis the PAA:IAA ratio in the whole seedling was approx. 15:1.

  11. Applied analysis of lacquer films based on pyrolysis-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Lu, Rong; Kamiya, Yukio; Miyakoshi, Tetsuo

    2006-09-15

    Ancient lacquer film, a Nanban lacquer film, an old lacquer-ware object imported from an Asian country, and the Baroque and Rococo lacquer films were analyzed by pyrolysis-gas chromatography/mass spectrometry. Compared with the results of the natural lacquer film, it was revealed that the ancient lacquer film and Nanban lacquer film were made from Rhus vernicifera, and the old lacquer-ware imported from an Asian country was made from Melanorrhoea usitata. However, the Baroque and Rococo lacquer films obtained from the Doerner Institute in Munich, Germany were made from natural resins. 3-Pentadecylcatechol (MW=320) (urushiol), 3-heptadecylcatechol (MW=348) (laccol), and 4-heptadecylcatechol (MW=348) (thitsiol) were the main products of the pyrolysis of R. vernicifera, Rhus succedanea, and M. usitata.

  12. Profiling of plasma metabolites in canine oral melanoma using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kawabe, Mifumi; Baba, Yuta; Tamai, Reo; Yamamoto, Ryohei; Komori, Masayuki; Mori, Takashi; Takenaka, Shigeo

    2015-08-01

    Malignant melanoma is one of the most common and aggressive tumors in the oral cavity of dog. The tumor has a poor prognosis, and methods for diagnosis and prediction of prognosis after treatment are required. Here, we examined metabolite profiling using gas chromatography-mass spectrometry (GC-MS) for development of a discriminant model for evaluation of prognosis. Metabolite profiles were evaluated in healthy and melanoma plasma samples using orthogonal projection to latent structure using discriminant analysis (OPLS-DA). Cases that were predicted to be healthy using the OPLS discriminant model had no advanced lesions after radiation therapy. These results indicate that metabolite profiling may be useful in diagnosis and prediction of prognosis of canine malignant melanoma.

  13. Determination of d-limonene in adipose tissue by gas chromatography-mass spectrometry

    Science.gov (United States)

    Miller, Jessica A.; Hakim, Iman A.; Thomson, Cynthia; Thompson, Patricia; Chow, H-H. Sherry

    2008-01-01

    We developed a novel method for analyzing d-limonene levels in adipose tissue. Fat samples were subjected to saponification followed by solvent extraction. d-Limonene in the sample extract was analyzed using gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring. Linear calibration curves were established over the mass range of 79.0-2,529 ng d-limonene per 0.1 grams of adipose tissue. Satisfactory within day precision (RSD 6.7 to 9.6%) and accuracy (% difference of −2.7 to 3.8%) and between day precision (RSD 6.0 to 10.7%) and accuracy (% difference of 1.8 to 2.6%) were achieved. The assay was successfully applied to human fat biopsy samples from a d-limonene feeding trial. PMID:18571481

  14. Extractive alkylation of 6-mercaptopurine and determination in plasma by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Floberg, S; Hartvig, P; Lindström, B; Lönner-Holm, G; Odlind, B

    1981-09-11

    An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentration of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography-mass spectrometry with multiple-ion detection. Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectively of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6 mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6 mercaptopurine in plasma.

  15. Determination of tetrahydrozoline in urine and blood using gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Peat, Judy; Garg, Uttam

    2010-01-01

    Tetrahydrozoline, a derivative of imidazoline, is widely used for the symptomatic relief of conjunctival and nasal congestion; however, intentional or unintentional high doses can result in toxicity manifested by hypotension, tachycardia, and CNS depression. The detection of the drug in blood and urine is helpful in the diagnosis and management of a toxic patient. For the analysis, plasma, serum, or urine is added to a tube containing alkaline buffer and organic extraction solvents, and tetrahydrozoline from the sample is extracted into the organic phase by gentle mixing. After centrifugation, the upper organic solvent layer containing the drug is removed and dried under stream of nitrogen at 40 degrees C. The residue is reconstituted in a hexane-ethanol mixture and analyzed using gas-chromatography-mass spectrometry. Quantitation of the drug is done by comparing responses of unknown sample to the responses of the calibrators using selected ion monitoring. Naphazoline is used as an internal standard.

  16. Simultaneous analysis of urinary phthalate metabolites of residents in Korea using isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Miok; Song, Na Rae; Choi, Jong-Ho; Lee, Jeongae; Pyo, Heesoo

    2014-02-01

    Phthalates are used in industry products, household items, and medical tools as plasticizers. Human exposure to phthalates has raised concern about its toxicity. In the present study, optimization was conducted for the simultaneous analysis of eight kinds of phthalate metabolites using gas chromatography-mass spectrometry (GC-MS): MEP, MiBP, MnBP, MBzP, MiNP, MEHP, MEOHP, and MEHHP. In order to minimize the matrix effect and to do quantitative analysis, isotope dilution and LLE-GC-MS methods were performed. Urine samples were enzymatically hydrolyzed, extracted with a mixture of n-hexane and ethyl ether (8:2; v:v), and subsequently derivatized with trimethylsilylation. All eight kinds of analytes showed clear resolution and high reproducibility in GC-MS results. The method detection limit ranged from 0.05 ng/mL to 0.2 ng/mL. Calibration curves were found to be linear from 0.2 to 100 ng/mL with -(2)>0.992. The relative standard deviation of the intraday precision using water and urine ranged from 2.1% to 16.3%. The analysis was performed with urine samples that were collected from adults residing in the Republic of Korea. The analyzed concentration results were compared according to gender and region. As a result, DEHP metabolites showed the highest detected concentration (75.92 μg/g creatinine, 100%), and MiNP, a metabolite of DiNP, showed the lowest detected concentration (0.42 μg/g creatinine, 22.5%). On average, female urine (200.76 μg/g creatinine) had a higher detected concentration of ∑8 phthalate metabolites than male urine. Samples from rural regions (211.96 μg/g creatinine) had higher levels than samples from urban regions. © 2013.

  17. Ganglioside Composition in Beef, Chicken, Pork, and Fish Determined Using Liquid Chromatography-High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Fong, Bertram Y; Ma, Lin; Khor, Geok Lin; van der Does, Yvonne; Rowan, Angela; McJarrow, Paul; MacGibbon, Alastair K H

    2016-08-17

    Gangliosides (GA) are found in animal tissues and fluids, such as blood and milk. These sialo-glycosphingolipids have bioactivities in neural development, the gastrointestinal tract, and the immune system. In this study, a high-performance liquid chromatography-mass spectrometry (HPLC-MS) method was validated to characterize and quantitate the GA in beef, chicken, pork, and fish species (turbot, snapper, king salmon, and island mackerel). For the first time, we report the concentration of GM3, the dominant GA in these foods, as ranging from 0.35 to 1.1 mg/100 g and 0.70 to 5.86 mg/100 g of meat and fish, respectively. The minor GAs measured were GD3, GD1a, GD1b, and GT1b. Molecular species distribution revealed that the GA contained long- to very-long-chain acyl fatty acids attached to the ceramide moiety. Fish GA contained only N-acetylneuraminic acid (NeuAc) sialic acid, while beef, chicken, and pork contained GD1a/b species that incorporated both NeuAc and N-glycolylneuraminic acid (NeuGc) and hydroxylated fatty acids.

  18. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R.

    1984-01-01

    The GABA analogue baclofen [3-(p-chlorophenyl)-4-aminobutanoic acid] has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies. (Auth.)

  19. Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry.

    Science.gov (United States)

    Matysik, Silke; Liebisch, Gerhard

    2017-12-01

    A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing

  1. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From

  2. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  3. Gas Chromatography-Mass Spectrometry for Metabolite Profiling of Japanese Black Cattle Naturally Contaminated with Zearalenone and Sterigmatocystin

    NARCIS (Netherlands)

    Toda, Katsuki; Kokushi, Emiko; Uno, Seiichi; Shiiba, Ayaka; Hasunuma, Hiroshi; Fushimi, Yasuo; Wijayagunawardane, Missaka P B; Zhang, Chunhua; Yamato, Osamu; Taniguchi, Masayasu; Fink-Gremmels, Johanna; Takagi, Mitsuhiro

    2017-01-01

    The objective of this study was to evaluate the metabolic profile of cattle fed with or without zearalenone (ZEN) and sterigmatocystin (STC)-contaminated diets using a gas chromatography-mass spectrometry metabolomics approach. Urinary samples were collected from individual animals (n = 6 per herd)

  4. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared

  5. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R.; Wilson, Ian D.; Somsen, Govert W.; de Jong, Gerhardus J.

    2014-01-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared

  6. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  7. High Resolution Tracking Devices Based on Capillaries Filled with Liquid Scintillator

    CERN Multimedia

    Bonekamper, D; Vassiltchenko, V; Wolff, T

    2002-01-01

    %RD46 %title\\\\ \\\\The aim of the project is to develop high resolution tracking devices based on thin glass capillary arrays filled with liquid scintillator. This technique provides high hit densities and a position resolution better than 20 $\\mu$m. Further, their radiation hardness makes them superior to other types of tracking devices with comparable performance. Therefore, the technique is attractive for inner tracking in collider experiments, microvertex devices, or active targets for short-lived particle detection. High integration levels in the read-out based on the use of multi-pixel photon detectors and the possibility of optical multiplexing allow to reduce considerably the number of output channels, and, thus, the cost for the detector.\\\\ \\\\New optoelectronic devices have been developed and tested: the megapixel Electron Bombarded CCD (EBCCD), a high resolution image-detector having an outstanding capability of single photo-electron detection; the Vacuum Image Pipeline (VIP), a high-speed gateable pi...

  8. Recent progress of task-specific ionic liquids in chiral resolution and extraction of biological samples and metal ions.

    Science.gov (United States)

    Wu, Datong; Cai, Pengfei; Zhao, Xiaoyong; Kong, Yong; Pan, Yuanjiang

    2018-01-01

    Ionic liquids have been functionalized for modern applications. The functional ionic liquids are also called task-specific ionic liquids. Various task-specific ionic liquids with certain groups have been constructed and exploited widely in the field of separation. To take advantage of their properties in separation science, task-specific ionic liquids are generally used in techniques such as liquid-liquid extraction, solid-phase extraction, gas chromatography, high-performance liquid chromatography, and capillary electrophoresis. This review mainly covers original research papers published in the last five years, and we will focus on task-specific ionic liquids as the chiral selectors in chiral resolution and as extractant or sensor for biological samples and metal ion purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  10. Isotope-dilution gas chromatography-mass spectrometry method for the analysis of hydroxyurea.

    Science.gov (United States)

    Garg, Uttam; Scott, David; Frazee, Clint; Kearns, Gregory; Neville, Kathleen

    2015-06-01

    Hydroxyurea is used in the treatment of various malignancies and sickle cell disease. There are limited studies on the pharmacokinetics of hydroxyurea, particularly in pediatric patients. An accurate, precise, and sensitive method is needed to support such studies and to monitor therapeutic adherence. We describe a novel gas chromatography-mass spectrometry (GC-MS) method for the determination of hydroxyurea concentration in plasma using stable labeled hydroxyurea C N2 as an internal standard. The method involved an organic extraction followed by the preparation of trimethylsilyl (TMS) derivatives of hydroxyurea for GC-MS selected ion-monitoring analysis. The following mass-to-charge (m/z) ratio ions for silated hydroxyurea and hydroxyurea C N2 were monitored: hydroxyurea-quantitative ion 277, qualifier ions 292 and 249; hydroxyurea C N2-quantitative ion 280, qualifier ion 295. This method was evaluated for reportable range, accuracy, within-run and between-run imprecisions, and limits of quantification. The reportable range for the method was 0.1-100 mcg/mL. All results were accurate within an allowable error of 15%. Within-run and between-run imprecisions were hydroxyurea described here is accurate, sensitive, precise, and robust. Its characteristics make the method suitable for supporting pharmacokinetic studies and/or clinical therapeutic monitoring.

  11. Magnetic solid phase extraction and gas chromatography-mass spectrometrical analysis of sixteen polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Cai, Ying; Yan, Zhihong; NguyenVan, Manh; Wang, Lijia; Cai, Qingyun

    2015-08-07

    Fluorenyl functionalized superparamagnetic core/shell magnetic nanoparticles (MNPs, Fe3O4@SiO2@Flu) were prepared and characterized by transmission electron microscope, X-ray diffraction and infrared spectroscopy. The MNPs having an average diameter of 200nm were then used as solid-phase extraction sorbent for the determination of 16 priority pollutants polycyclic aromatic hydrocarbons (PAHs) in water samples designated by United States Environmental Protection Agency (U.S. EPA). The main influencing parameters, including sorbent amount, desorption solvent, sample volume and extraction time were optimized. Analyses were performed on gas chromatography-mass spectrometry (GC-MS) using selected ion monitoring (SIM) mode. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels. Limit of detection ranging from 0.5 to 4.0ng/L were obtained. The repeatability was investigated by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) lower than 13.1%. Finally, the proposed method was successfully applied for the determination of PAHs in water samples with the recoveries in the range of 96.0-106.7%. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Analysis of 62 synthetic cannabinoids by gas chromatography-mass spectrometry with photoionization.

    Science.gov (United States)

    Akutsu, Mamoru; Sugie, Ken-Ichi; Saito, Koichi

    2017-01-01

    Gas chromatography-mass spectrometry (GC-MS) in electron ionization (EI) mode is one of the most commonly used techniques for analysis of synthetic cannabinoids, because the GC-EI-MS spectra contain characteristic fragment ions for identification of a compound; however, the information on its molecular ions is frequently lacking. To obtain such molecular ion information, GC-MS in chemical ionization (CI) mode is frequently used. However, GC-CI-MS requires a relatively tedious process using reagent gas such as methane or isobutane. In this study, we show that GC-MS in photoionization (PI) mode provided molecular ions in all spectra of 62 synthetic cannabinoids, and 35 of the 62 compounds showed only the molecular radical cations. Except for the 35 compounds, the PI spectra showed very simple patterns with the molecular peak plus only a few fragment peak(s). An advantage is that the ion source for GC-PI-MS can easily be used for GC-EI-MS as well. Therefore, GC-EI/PI-MS will be a useful tool for the identification of synthetic cannabinoids contained in a dubious product. To the best of our knowledge, this is the first report to use GC-PI-MS for analysis of synthetic cannabinoids.

  13. Metabolic Profiling and Quantification of Neurotransmitters in Mouse Brain by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Jäger, Christian; Hiller, Karsten; Buttini, Manuel

    2016-09-01

    Metabolites are key mediators of cellular functions, and have emerged as important modulators in a variety of diseases. Recent developments in translational biomedicine have highlighted the importance of not looking at just one disease marker or disease inducing molecule, but at populations thereof to gain a global understanding of cellular function in health and disease. The goal of metabolomics is the systematic identification and quantification of metabolite populations. One of the most pressing issues of our times is the understanding of normal and diseased nervous tissue functions. To ensure high quality data, proper sample processing is crucial. Here, we present a method for the extraction of metabolites from brain tissue, their subsequent preparation for non-targeted gas chromatography-mass spectrometry (GC-MS) measurement, as well as giving some guidelines for processing of raw data. In addition, we present a sensitive screening method for neurotransmitters based on GC-MS in selected ion monitoring mode. The precise multi-analyte detection and quantification of amino acid and monoamine neurotransmitters can be used for further studies such as metabolic modeling. Our protocol can be applied to shed light on nervous tissue function in health, as well as neurodegenerative disease mechanisms and the effect of experimental therapeutics at the metabolic level. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  14. Assessment of herbicides and organochlorine pesticides contamination in agricultural soils using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Wan-Hong; Wang, Shi-Cheng; Wang, Yan-Hong

    2008-01-01

    A rapid multi-residue method for the simultaneous analysis of 3 herbicides and 8 organochlorine pesticides (OCPs) in agricultural soils has been developed, using ultrasonic solvent extraction coupled with gas chromatography-mass spectrometry (GC-MS). The recoveries ranged from 81% to 117% with a relative standard deviation (R.S.D) lower than 15%. The limits of quantification (LOQs) ranged from 0.03 to 1.06 microg x kg(-1) dry weight for different pesticides studied. The proposed method has been applied to investigate the 11 pesticide residues in agricultural soils collected from Liaoning Province, northeast of China. 3 OCPs and 3 herbicides were identified. Acetochlor, atrazine, butachtor were measured in the relatively high level with values ranging from 0.53 to 203.18 microg x kg(-1), 0.14 to 21.20 microg x kg(-1), pesticides in this study was compared with the date of other countries reported and the corresponding limiting values used in Netherland, USA, Canada, Vietnam and Thailand. Among the herbicide residues, there was a significant relativity between soil utilizing types and their residue concentration. It seems that the monitoring action for soil contamination caused by commonly-used herbicides should be enhanced according to soil utilizing types, especially acetochlor in maize field.

  15. Integration of gas chromatography mass spectrometry methods for differentiating ricin preparation methods.

    Science.gov (United States)

    Wunschel, David S; Melville, Angela M; Ehrhardt, Christopher J; Colburn, Heather A; Victry, Kristin D; Antolick, Kathryn C; Wahl, Jon H; Wahl, Karen L

    2012-05-07

    The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of Ricinus communis, commonly known as the castor plant. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatography-mass spectrometry (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid, as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods, starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid, or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method, independent of the seed source. In particular, the abundance of mannose, arabinose, fucose, ricinoleic acid, and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation than would be possible using a single analytical method.

  16. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  17. The analysis of common metabolites of organophosphorus pesticides in urine by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Park, Seong Soo; Pyo, Hee Soo; Lee, Kang Jin; Park, Song Ja; Park, Taek Kyu

    1998-01-01

    Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2:1:10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 μg/ml in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants

  18. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division; China Univ. of Geosciences, Wuhan (China). School of Environmental Studies; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division

    2009-07-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  19. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Yang, Z.; China Univ. of Geosciences, Wuhan; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M.

    2009-01-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  20. Exploring the Metabolomic Responses of Bacillus licheniformis to Temperature Stress by Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Dong, Zixing; Chen, Xiaoling; Cai, Ke; Chen, Zhixin; Wang, Hongbin; Jin, Peng; Liu, Xiaoguang; Permaul, Kugenthiren; Singh, Suren; Wang, Zhengxiang

    2018-03-28

    Owing to its high protein secretion capacity, simple nutritional requirements, and GRAS (generally regarded as safe) status, Bacillus licheniformis is widely used as a host for the industrial production of enzymes, antibiotics, and peptides. However, as compared with its close relative Bacillus subtilis , little is known about the physiology and stress responses of B. licheniformis . To explore its temperature-stress metabolome, B. licheniformis strains ATCC 14580 and B186, with respective optimal growth temperatures of 42°C and 50°C, were cultured at 42°C, 50°C, and 60°C and their corresponding metabolic profiles were determined by gas chromatography/mass spectrometry and multivariate statistical analyses. It was found that with increased growth temperatures, the two B. licheniformis strains displayed elevated cellular levels of proline, glutamate, lysine, pentadecanoic acid, hexadecanoic acid, heptadecanoic acid, and octadecanoic acid, and decreased levels of glutamine and octadecenoic acid. Regulation of amino acid and fatty acid metabolism is likely to be associated with the evolution of protective biochemical mechanisms of B. licheniformis . Our results will help to optimize the industrial use of B. licheniformis and other important Bacillus species.

  1. [Determination of five representative ultraviolet filters in water by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Ding, Yiran; Huang, Yun; Zhao, Tingting; Cai, Qian; Luo, Yu; Huang, Bin; Zhang, Yuxia; Pan, Xuejun

    2014-06-01

    A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.

  2. Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Fryš, Ondřej; Česla, Petr; Bajerová, Petra; Adam, Martin; Ventura, Karel

    2012-09-15

    A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Postmortem interval estimation: a novel approach utilizing gas chromatography/mass spectrometry-based biochemical profiling.

    Science.gov (United States)

    Kaszynski, Richard H; Nishiumi, Shin; Azuma, Takeshi; Yoshida, Masaru; Kondo, Takeshi; Takahashi, Motonori; Asano, Migiwa; Ueno, Yasuhiro

    2016-05-01

    While the molecular mechanisms underlying postmortem change have been exhaustively investigated, the establishment of an objective and reliable means for estimating postmortem interval (PMI) remains an elusive feat. In the present study, we exploit low molecular weight metabolites to estimate postmortem interval in mice. After sacrifice, serum and muscle samples were procured from C57BL/6J mice (n = 52) at seven predetermined postmortem intervals (0, 1, 3, 6, 12, 24, and 48 h). After extraction and isolation, low molecular weight metabolites were measured via gas chromatography/mass spectrometry (GC/MS) and examined via semi-quantification studies. Then, PMI prediction models were generated for each of the 175 and 163 metabolites identified in muscle and serum, respectively, using a non-linear least squares curve fitting program. A PMI estimation panel for muscle and serum was then erected which consisted of 17 (9.7%) and 14 (8.5%) of the best PMI biomarkers identified in muscle and serum profiles demonstrating statistically significant correlations between metabolite quantity and PMI. Using a single-blinded assessment, we carried out validation studies on the PMI estimation panels. Mean ± standard deviation for accuracy of muscle and serum PMI prediction panels was -0.27 ± 2.88 and -0.89 ± 2.31 h, respectively. Ultimately, these studies elucidate the utility of metabolomic profiling in PMI estimation and pave the path toward biochemical profiling studies involving human samples.

  5. Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater.

    Science.gov (United States)

    Lamas, J Pablo; Sanchez-Prado, Lucia; Garcia-Jares, Carmen; Llompart, Maria

    2009-07-01

    A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 degrees C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL(-1). Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern.

  6. [Determination of olive oil content in olive blend oil by headspace gas chromatography-mass spectrometry].

    Science.gov (United States)

    Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao

    2017-07-08

    A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.

  7. Determination of pyrrolizidine alkaloids in selected feed materials with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kowalczyk, Ewelina; Kwiatek, Krzysztof

    2017-05-01

    1,2-Dehydropyrrolizidine alkaloids are known to be toxic to many animals and humans. To provide safety of feeds a method based on gas chromatography-mass spectrometry enabling the determination of a content of 1,2-unsaturated PAs in feed materials was developed. After extraction with aqueous solution of HCl and purification of the extract, 1,2-unsaturated alkaloids are reduced to their common backbone structures and subsequently derivatised with heptafluorobutyric anhydride (HFBA). The method was validated according to SANTE/11945/2015. All received parameters are consistent with the document requirements as recovery of a final compound retronecine derivative was from 81.8% to 94.4% when retrosine was used for spiking and from 72.7% to 85.5% when retrorsine N-oxide was spiked. The repeatability was calculated as relative standards deviation and ranged from 7.5% to 14.4%, for N-oxide was from 7.9% to 15.4%. The reproducibility was in the range from 14.2% to 16.3% and from 17.0% to 18.1% for free base and N-oxide respectively. The limit of quantification was determined as 10 µg kg - 1 . Good linearity of the method was obtained with coefficient of determination R 2  > 0.99. The method was applied to 35 silage and two hay samples analysis.

  8. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  9. High-resolution tracking using large capillary bundles filled with liquid scintillator

    CERN Document Server

    Annis, P; Benussi, L; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Van Dantzig, R; Dupraz, J P; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Feyt, J; Frekers, D; Frenkel, A; Galeazzi, F; Garufi, F; Goldberg, J; Golovkin, S V; Gorin, A M; Grégoire, G; Harrison, K; Höpfner, K; Holtz, K; Konijn, J; Kozarenko, E N; Kreslo, I E; Kushnirenko, A E; Liberti, B; Martellotti, G; Medvedkov, A M; Michel, L; Migliozzi, P; Mommaert, C; Mondardini, M R; Panman, J; Penso, G; Petukhov, Yu P; Rondeshagen, D; Siegmund, W P; Tyukov, V E; Van Beek, G; Vasilchenko, V G; Vilain, P; Visschers, J L; Wilquet, G; Winter, Klaus; Wolff, T; Wörtche, H J; Wong, H; Zimyn, K V

    2000-01-01

    We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of \\hbox{$\\approx 10^6$} capillaries with \\hbox{20$-$25 $\\mu$m} diameter and \\hbox{0.9$-$1.8 m} length, have been tested, and a spatial resolution of the order of \\hbox{20$-$40 $\\mu$m} has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were $\\sim$ 8 hits/mm at the readout window, and \\hbox{$\\sim$ 3 ...

  10. High-resolution liquid patterns via three-dimensional droplet shape control.

    Science.gov (United States)

    Raj, Rishi; Adera, Solomon; Enright, Ryan; Wang, Evelyn N

    2014-09-25

    Understanding liquid dynamics on surfaces can provide insight into nature's design and enable fine manipulation capability in biological, manufacturing, microfluidic and thermal management applications. Of particular interest is the ability to control the shape of the droplet contact area on the surface, which is typically circular on a smooth homogeneous surface. Here, we show the ability to tailor various droplet contact area shapes ranging from squares, rectangles, hexagons, octagons, to dodecagons via the design of the structure or chemical heterogeneity on the surface. We simultaneously obtain the necessary physical insights to develop a universal model for the three-dimensional droplet shape by characterizing the droplet side and top profiles. Furthermore, arrays of droplets with controlled shapes and high spatial resolution can be achieved using this approach. This liquid-based patterning strategy promises low-cost fabrication of integrated circuits, conductive patterns and bio-microarrays for high-density information storage and miniaturized biochips and biosensors, among others.

  11. High Resolution Temperature Measurement of Liquid Stainless Steel Using Hyperspectral Imaging

    Directory of Open Access Journals (Sweden)

    Wim Devesse

    2017-01-01

    Full Text Available A contactless temperature measurement system is presented based on a hyperspectral line camera that captures the spectra in the visible and near infrared (VNIR region of a large set of closely spaced points. The measured spectra are used in a nonlinear least squares optimization routine to calculate a one-dimensional temperature profile with high spatial resolution. Measurements of a liquid melt pool of AISI 316L stainless steel show that the system is able to determine the absolute temperatures with an accuracy of 10%. The measurements are made with a spatial resolution of 12 µm/pixel, justifying its use in applications where high temperature measurements with high spatial detail are desired, such as in the laser material processing and additive manufacturing fields.

  12. [Application of liquid chromatography-high resolution mass spectrometry in toxicological screening].

    Science.gov (United States)

    Li, Xiao-Wen; Shen, Bao-Hua; Zhuo, Xian-Yi

    2011-10-01

    Due to the diversity of toxicologically relevant substances, the uncertainty of target compounds and the specificity of samples, toxicological screening techniques have always been valued by the forensic toxicologists. Depending on its powerful separation ability, superhigh resolution and accurate mass measurement, combined with the two levels spectrum database matching and abundance ratio of isotope ion, the liquid chromatography-high resolution mass spectrometry (LC-HRMS) analyzers have increasingly advantage in screening and identification of chemical compound. This review focuses on the applications of LC-HRMS in screening and identification of drug-of-abuse, prescription drugs, pesticide and stimulant. The prospect of LC-HRMS in forensic toxicology analysis is also included.

  13. The simultaneous separation and determination of chloropropanols in soy sauce and other flavoring with gas chromatography-mass spectrometry in negative chemical and electron impact ionization modes.

    Science.gov (United States)

    Xu, Xiaomin; Ren, Yiping; Wu, Pinggu; Han, Jianlong; Shen, Xianghong

    2006-02-01

    Both gas chromatography-mass spectrometry in electron ionization (GC-MS-EI) and negative chemical ionization (GC-MS-NCI) modes are reported in this paper for the simultaneous determination of 1,3-dichloropropan-2-ol (1,3-DCP), 2,3-dichloropropan-1-ol (2,3-DCP), 3-chloropropane-1,2-diol (3-MCPD) and 2-chloropropane-1,3-diol (2-MCPD) in soy sauce and other flavoring. D(5)-3-MCPD (for 3-MCPD and 2-MCPD) and d(5)-1,3-DCP (for 1,3-DCP and 2,3-DCP) were used as the deuterium isotopic labelled internal standards. The feasibility of using heptafluorobutyric anhydride modified with triethylamine (HFBA-Et(3)N) as a new derivatization reagent to replace heptafluorobutyrylimidazole (HFBI) is proposed. Liquid/liquid extraction with hexane was introduced for high lipid content samples. A small survey was carried out of soy sauces (103 samples) and instant noodles (45 samples) and the applicability of GC-MS-NCI and GC-MS-EI was assessed in these different matrices.

  14. Studies on the metabolism and toxicological detection of the designer drug 4-methylthioamphetamine (4-MTA) in human urine using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ewald, Andreas H; Peters, Frank T; Weise, Magdalene; Maurer, Hans H

    2005-09-25

    4-Methylthioamphetamine (4-MTA) is a scheduled designer drug that has appeared on the illicit drug market and led to several non-fatal or even fatal poisonings. Only few data are available on its metabolism. The first aim of this study was to identify the 4-MTA metabolites in human urine and then to study whether the authors' STA procedure is suitable for screening for and identification of 4-MTA and/or its metabolites in urine. After enzymatic cleavage of conjugates, solid-phase extraction (SPE) and acetylation the following metabolites could be identified by full-scan gas chromatography-mass spectrometry (GC-MS): deamino-oxo 4-MTA, deamino-hydroxy 4-MTA, ring hydroxy and beta-hydroxy 4-MTA. 4-MTA sulfoxide could be identified as possible artifact. In urine samples after enzymatic hydrolysis, acidic extraction, and methylation, 4-methylthiobenzoic acid could be identified. The authors' systematical toxicological analysis (STA) procedure using full-scan GC-MS after acid hydrolysis, liquid-liquid extraction (LLE) and acetylation allowed detection of 4-MTA as target analyte plus all the above-mentioned metabolites with the exception of 4-methylthiobenzoic acid. The extraction efficiency of 4-MTA was approximately 70% and the limit of detection (LOD) was 30 ng/ml (S/N 3).

  15. Classification of bacteria by simultaneous methylation-solid phase microextraction and gas chromatography/mass spectrometry analysis of fatty acid methyl esters.

    Science.gov (United States)

    Lu, Yao; Harrington, Peter B

    2010-08-01

    Direct methylation and solid-phase microextraction (SPME) were used as a sample preparation technique for classification of bacteria based on fatty acid methyl ester (FAME) profiles. Methanolic tetramethylammonium hydroxide was applied as a dual-function reagent to saponify and derivatize whole-cell bacterial fatty acids into FAMEs in one step, and SPME was used to extract the bacterial FAMEs from the headspace. Compared with traditional alkaline saponification and sample preparation using liquid-liquid extraction, the method presented in this work avoids using comparatively large amounts of inorganic and organic solvents and greatly decreases the sample preparation time as well. Characteristic gas chromatography/mass spectrometry (GC/MS) of FAME profiles was achieved for six bacterial species. The difference between Gram-positive and Gram-negative bacteria was clearly visualized with the application of principal component analysis of the GC/MS data of bacterial FAMEs. A cross-validation study using ten bootstrap Latin partitions and the fuzzy rule building expert system demonstrated 87 +/- 3% correct classification efficiency.

  16. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples.

    Science.gov (United States)

    Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M

    2012-02-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.

  17. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

    Directory of Open Access Journals (Sweden)

    E. Gerace

    2012-02-01

    Full Text Available A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. Keywords: Anti-estrogens, Fast-GC/MS, Urine screening, Validation, Breast cancer

  18. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Song, Hu; Peng, Jun-Sheng; Yao, Dong-Sheng; Yang, Zu-Li; Liu, Huan-Liang; Zeng, Yi-Ke; Shi, Xian-Ping; Lu, Bi-Yan

    2011-01-01

    Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS) was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA). Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV) of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP) value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1) and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms

  19. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-05-05

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Classical electron ionization mass spectra in gas chromatography/mass spectrometry with supersonic molecular beams.

    Science.gov (United States)

    Gordin, Alexander; Fialkov, Alexander B; Amirav, Aviv

    2008-09-01

    A major benefit of gas chromatography/mass spectrometry (GC/MS) with a supersonic molecular beam (SMB) interface and its fly-through ion source is the ability to obtain electron ionization of vibrationally cold molecules (cold EI), which show enhanced molecular ions. However, GC/MS with an SMB also has the flexibility to perform 'classical EI' mode of operation which provides mass spectra to mimic those in commercial 70 eV electron ionization MS libraries. Classical EI in SMB is obtained through simple reduction of the helium make-up gas flow rate, which reduces the SMB cooling efficiency; hence the vibrational temperatures of the molecules are similar to those in traditional EI ion sources. In classical EI-SMB mode, the relative abundance of the molecular ion can be tuned and, as a result, excellent identification probabilities and very good matching factors to the NIST MS library are obtained. Classical EI-SMB with the fly-through dual cage ion source has analyte sensitivity similar to that of the standard EI ion source of a basic GC/MS system. The fly-through EI ion source in combination with the SMB interface can serve for cold EI, classical EI-SMB, and cluster chemical ionization (CCI) modes of operation, all easily exchangeable through a simple and quick change (not involving hardware). Furthermore, the fly-through ion source eliminates sample scattering from the walls of the ion source, and thus it offers full sample inertness, tailing-free operation, and no ion-molecule reaction interferences. It is also robust and enables increased column flow rate capability without affecting the sensitivity.

  1. Analysis of essential oil of eaglewood tree (Aquilaria agallocha Roxb. by gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Mohammad Nazrul Islam Bhuiyan

    2009-06-01

    Full Text Available The study was carried out to find out the differences in composition of oils obtained from healthy, naturally infected and artificially screws wounds eaglewood (Aquilaria agallocha Roxb. using gas chromatography mass spectrometry (GC-MS analysis. Natural healthy plants agar contained octacosane (19.83%, naphthalene, 1,2,3,5,6,7,8,8a-octahydro-1,8a-dimethyl-7-(1-methylethenyl-, [1R-(1.alpha.,7.beta.,8a.alpha.]- (12.67%, 5-isobutyramido-2-methyl pyrimidine (13.52%, caryophyllene oxide (11.25% and (.+-.-cadinene (5.46%. Natural infected plants agar (super agar contained cycloheptane, 4-methylene-1-methyl-2-(2-methyl-1-propen-1-yl-1-vinyl- (46.17%, caryophyllene oxide (33.00% and 7-Isopropenyl-4a-methyl-1-methylenedecahydronaphthalene (20.83%. Artificially screw injected plants agar contained diisooctyl phthalate (71.97%, 1H-Cycloprop[e]azulen-4-ol, decahydro-1,1,4,7-tetramethyl-, [1ar-(1a.alpha.,4.beta.,4a.beta., 7.alpha., 7a.beta., 7b.alpha.]- (9.16%, hexadecanoic acid (7.05%, naphthalene, 1,2,3,5,6,7,8,8a-octahydro-1,8a-dimethyl-7-(1-methylethenyl-, [1R-(1.alpha.,7.beta.,8a.alpha.]- (6.45% and aristolene (5.36%. This study showed a marked difference in the oil compositions among the treatments with regards to their quality.

  2. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Higgins, C.E.; Jenkins, R.A.

    1994-05-01

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4 degree C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range

  3. Identification of organic acids as potential biomarkers in the urine of autistic children using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Kałużna-Czaplińska, Joanna; Żurawicz, Ewa; Struck, Wiktoria; Markuszewski, Michał

    2014-09-01

    There is a need to identify metabolic phenotypes in autism as they might each require unique approaches to prevention. Biological markers can help define autism subtypes and reveal potential therapeutic targets. The aim of the study was to identify alterations of small molecular weight compounds and to find potential biomarkers. Gas chromatography/mass spectrometry was employed to evaluate major metabolic changes in low molecular weight urine metabolites of 14 children with autism spectrum disorders vs. 10 non-autistic subjects. The results prove the usefulness of an identified set of 21 endogenous compounds (including 14 organic acids), whose levels are changed in diseased children. Gas chromatography/mass spectrometry method combined with multivariate statistical analysis techniques provide an efficient way of depicting metabolic perturbations of diseases, and may potentially be applicable as a novel strategy for the noninvasive diagnosis and treatment of autism. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Tracking juniper berry content in oils and distillates by spectral deconvolution of gas chromatography/mass spectrometry data.

    Science.gov (United States)

    Robbat, Albert; Kowalsick, Amanda; Howell, Jessalin

    2011-08-12

    The complex nature of botanicals and essential oils makes it difficult to identify all of the constituents by gas chromatography/mass spectrometry (GC/MS) alone. In this paper, automated sequential, multidimensional gas chromatography/mass spectrometry (GC-GC/MS) was used to obtain a matrix-specific, retention time/mass spectrometry library of 190 juniper berry oil compounds. GC/MS analysis on stationary phases with different polarities confirmed the identities of each compound when spectral deconvolution software was used to analyze the oil. Also analyzed were distillates of juniper berry and its oil as well as gin from four different manufacturers. Findings showed the chemical content of juniper berry can be traced from starting material to final product and can be used to authenticate and differentiate brands. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Analysis of pharmaceutical and other organic wastewater compounds in filtered and unfiltered water samples by gas chromatography/mass spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Phillips, Patrick J.; Smith, Steven G.

    2014-01-01

    Research on the effects of exposure of stream biota to complex mixtures of pharmaceuticals and other organic compounds associated with wastewater requires the development of additional analytical capabilities for these compounds in water samples. Two gas chromatography/mass spectrometry (GC/MS) analytical methods used at the U.S. Geological Survey National Water Quality Laboratory (NWQL) to analyze organic compounds associated with wastewater were adapted to include additional pharmaceutical and other organic compounds beginning in 2009. This report includes a description of method performance for 42 additional compounds for the filtered-water method (hereafter referred to as the filtered method) and 46 additional compounds for the unfiltered-water method (hereafter referred to as the unfiltered method). The method performance for the filtered method described in this report has been published for seven of these compounds; however, the addition of several other compounds to the filtered method and the addition of the compounds to the unfiltered method resulted in the need to document method performance for both of the modified methods. Most of these added compounds are pharmaceuticals or pharmaceutical degradates, although two nonpharmaceutical compounds are included in each method. The main pharmaceutical compound classes added to the two modified methods include muscle relaxants, opiates, analgesics, and sedatives. These types of compounds were added to the original filtered and unfiltered methods largely in response to the tentative identification of a wide range of pharmaceutical and other organic compounds in samples collected from wastewater-treatment plants. Filtered water samples are extracted by vacuum through disposable solid-phase cartridges that contain modified polystyrene-divinylbenzene resin. Unfiltered samples are extracted by using continuous liquid-liquid extraction with dichloromethane. The compounds of interest for filtered and unfiltered sample

  6. Direct Growth of Bacteria in Headspace Vials Allows for Screening of Volatiles by Gas Chromatography Mass Spectrometry

    OpenAIRE

    Collin M. Timm; Evan P. Lloyd; Amanda Egan; Ray Mariner; David Karig

    2018-01-01

    Bacterially produced volatile organic compounds (VOCs) can modify growth patterns of eukaryotic hosts and competing/cohabiting microbes. These compounds have been implicated in skin disorders and attraction of biting pests. Current methods to detect and characterize VOCs from microbial cultures can be laborious and low-throughput, making it difficult to understand the behavior of microbial populations. In this work we present an efficient method employing gas chromatography/mass spectrometry ...

  7. Ink dating using thermal desorption and gas chromatography / mass spectrometry: comparison of results obtained in two laboratories

    OpenAIRE

    Koenig, A.; Bügler, J.; Kirsch, D.; Köhler, F.; Weyermann, C.

    2015-01-01

    Recent ink dating methods focused mainly on changes in solvent amounts occurring over time. A promising method was developed at the Landeskriminalamt of Munich using thermal desorption (TD) followed by gas chromatography / mass spectrometry (GC/MS) analysis. Sequential extractions of the phenoxyethanol present in ballpoint pen ink entries were carried out at two different temperatures. This method is applied in forensic practice and is currently implemented in several laboratories participati...

  8. Super-resolution with an optically-addressable liquid crystal spatial light modulator

    International Nuclear Information System (INIS)

    McOrist, J.; Sharma, M.D.; Sheppard, C.J.R.

    2002-01-01

    Full text: An optically-addressable liquid crystal spatial light modulator has been used to generate super-resolving masks. This approach avoids problems of low efficiency and coupling between amplitude and phase modulation, that occur when using conventional liquid crystal modulators. When addressed by a programmed light intensity distribution, it allows filters to be changed rapidly to modify the response of a system or permit the investigation of different filter designs. The device used is not pixellated, with a spatial resolution of 30 line pairs/mm over an area 18mm X 18mm, and can achieve continuously-variable phase modulation up to 1.5 wavelengths. The system consists of a write-beam that is collimated from a white-light source. An input mask was used in our experiments determines the modulation pattern of the read-beam. The read-beam from a HeNe laser reflects from the modulator and is focused by a microscope objective. The value of the phase change induced by the transparent regions of the mask can be altered continuously by adjusting the brightness of the write-beam. We have used this system to attain super-resolution by simple Toraldo filters, consisting of arrays of rings. Copyright (2002) Australian Society for Electron Microscopy Inc

  9. A Liquid-Cryogen-Free Cryostat for Ultrahigh Resolution Gamma-Ray Spectrometers

    International Nuclear Information System (INIS)

    Dreyer, J.G.; Hertrich, T.; Drury, O.B.; Hohne, J.; Friedrich, S.

    2008-01-01

    We are developing ultra-high energy resolution gamma-ray detectors based on superconducting transition edge sensors (TESs) for nuclear non-proliferation and fundamental science applications. They use bulk tin absorbers attached to molybdenum-copper multilayer TESs, and have achieved an energy resolution between 50 and 90 eV FWHM for gamma-ray energies below 122 keV. For increased user-friendliness, we have built a cryostat that attains the required detector operating temperature of 0.1 K at the push of a button without the use of cryogenic liquids. It uses a two-stage mechanical pulse tube refrigerator for precooling to ∼3 K, and a two-stage adiabatic demagnetization refrigerator for cooling to the base temperature. The cryostat is fully automated, attains a base temperature below 30 mK without the use of cryogenic liquids, and has a hold time of ∼2 days at 0.1 K between 1-hour demagnetization cycles. Here we discuss the performance of the cryostat for operation in a Gamma-spectrometer with 112-pixel arrays of superconducting TES detectors

  10. Resolving of challenging gas chromatography-mass spectrometry peak clusters in fragrance samples using multicomponent factorization approaches based on polygon inflation algorithm.

    Science.gov (United States)

    Ghaheri, Salehe; Masoum, Saeed; Gholami, Ali

    2016-01-15

    Analysis of fragrance composition is very important for both the fragrance producers and consumers. Unraveling of fragrance formulation is necessary for quality control, competitor and trace analysis. Gas chromatography-mass spectrometry (GC-MS) has been introduced as the most appropriate analytical technique for this type of analysis, which is based on Kovats index and MS database. The most straightforward method to analyze a GC-MS dataset is to integrate those peaks that can be recognized by their mass profiles. But, because of common problems of chromatographic data such as spectral background, baseline offset and specially overlapped peaks, accurate quantitative and qualitative analysis could be failed. Some chemometric modeling techniques such as bilinear multivariate curve resolution (MCR) methods have been introduced to overcome these problems and obtained well resolved chromatographic profiles. The main drawback of these methods is rotational ambiguity or nonunique solution that is represented as area of feasible solutions (AFS). Polygonal inflation algorithm (PIA) is an automatic and simple to use algorithm for numerical computation of AFS. In this study, the extent of rotational ambiguity in curve resolution methods is calculated by MCR-BAND toolbox and the PIA. The ability of the PIA in resolving GC-MS data sets is evaluated by simulated GC-MS data in comparison with other popular curve resolution methods such as multivariate curve resolution alternative least square (MCR-ALS), multivariate curve resolution objective function minimization (MCR-FMIN) by different initial estimation methods and independent component analysis (ICA). In addition, two typical challenging area of total ion chromatogram (TIC) of commercial fragrances with overlapped peaks were analyzed by the PIA to investigate the possibility of peak deconvolution analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Magnetic headspace adsorptive extraction of chlorobenzenes prior to thermal desorption gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Vidal, Lorena; Ahmadi, Mazaher; Fernández, Elena; Madrakian, Tayyebeh; Canals, Antonio

    2017-01-01

    This study presents a new, user-friendly, cost-effective and portable headspace solid-phase extraction technique based on graphene oxide decorated with iron oxide magnetic nanoparticles as sorbent, located on one end of a small neodymium magnet. Hence, the new headspace solid-phase extraction technique has been called Magnetic Headspace Adsorptive Extraction (Mag-HSAE). In order to assess Mag-HSAE technique applicability to model analytes, some chlorobenzenes were extracted from water samples prior to gas chromatography-mass spectrometry determination. A multivariate approach was employed to optimize the experimental parameters affecting Mag-HSAE. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; extraction time, 30 min; sorbent amount, 10 mg; stirring speed, 1500 rpm, and ionic strength, non-significant), obtaining a linear response from 0.5 to 100 ng L −1 for 1,3-DCB, 1,4-DCB, 1,2-DCB, 1,3,5-TCB, 1,2,4-TCB and 1,2,3-TCB; from 0.5 to 75 ng L −1 for 1,2,4,5-TeCB, and PeCB; and from 1 to 75 ng L −1 for 1,2,3,4-TeCB. The repeatability of the proposed method was evaluated at 10 ng L −1 and 50 ng L −1 spiking levels, and coefficients of variation ranged between 1.5 and 9.5% (n = 5). Limits of detection values were found between 93 and 301 pg L −1 . Finally, tap, mineral and effluent water were selected as real water samples to assess method applicability. Relative recoveries varied between 86 and 110% showing negligible matrix effects. - Highlights: • A new extraction technique named Magnetic Headspace Adsorptive Extraction is presented. • Graphene oxide/iron oxide composite deposited on a neodymiun magnet as sorbent. • Sorbent of low cost, rapid and simple synthesis, easy manipulation and portability options. • Fast and efficient extraction and sensitive determination of chlorobenzenes in water samples.

  12. Magnetic headspace adsorptive extraction of chlorobenzenes prior to thermal desorption gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena, E-mail: lorena.vidal@ua.es [Department of Analytical Chemistry, Nutrition and Food Sciences and University Institute of Materials, University of Alicante, P.O. Box 99, E-03080, Alicante (Spain); Ahmadi, Mazaher [Faculty of Chemistry, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of); Fernández, Elena [Department of Analytical Chemistry, Nutrition and Food Sciences and University Institute of Materials, University of Alicante, P.O. Box 99, E-03080, Alicante (Spain); Madrakian, Tayyebeh [Faculty of Chemistry, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of); Canals, Antonio, E-mail: a.canals@ua.es [Department of Analytical Chemistry, Nutrition and Food Sciences and University Institute of Materials, University of Alicante, P.O. Box 99, E-03080, Alicante (Spain)

    2017-06-08

    This study presents a new, user-friendly, cost-effective and portable headspace solid-phase extraction technique based on graphene oxide decorated with iron oxide magnetic nanoparticles as sorbent, located on one end of a small neodymium magnet. Hence, the new headspace solid-phase extraction technique has been called Magnetic Headspace Adsorptive Extraction (Mag-HSAE). In order to assess Mag-HSAE technique applicability to model analytes, some chlorobenzenes were extracted from water samples prior to gas chromatography-mass spectrometry determination. A multivariate approach was employed to optimize the experimental parameters affecting Mag-HSAE. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; extraction time, 30 min; sorbent amount, 10 mg; stirring speed, 1500 rpm, and ionic strength, non-significant), obtaining a linear response from 0.5 to 100 ng L{sup −1} for 1,3-DCB, 1,4-DCB, 1,2-DCB, 1,3,5-TCB, 1,2,4-TCB and 1,2,3-TCB; from 0.5 to 75 ng L{sup −1} for 1,2,4,5-TeCB, and PeCB; and from 1 to 75 ng L{sup −1} for 1,2,3,4-TeCB. The repeatability of the proposed method was evaluated at 10 ng L{sup −1} and 50 ng L{sup −1} spiking levels, and coefficients of variation ranged between 1.5 and 9.5% (n = 5). Limits of detection values were found between 93 and 301 pg L{sup −1}. Finally, tap, mineral and effluent water were selected as real water samples to assess method applicability. Relative recoveries varied between 86 and 110% showing negligible matrix effects. - Highlights: • A new extraction technique named Magnetic Headspace Adsorptive Extraction is presented. • Graphene oxide/iron oxide composite deposited on a neodymiun magnet as sorbent. • Sorbent of low cost, rapid and simple synthesis, easy manipulation and portability options. • Fast and efficient extraction and sensitive determination of chlorobenzenes in water samples.

  13. Plasma metabolomic profiling of dairy cows affected with ketosis using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Zhang, Hongyou; Wu, Ling; Xu, Chuang; Xia, Cheng; Sun, Lingwei; Shu, Shi

    2013-09-26

    Ketosis is an important problem for dairy cows` production performance. However, it is still little known about plasma metabolomics details of dairy ketosis. A gas chromatography/mass spectrometry (GC/MS) technique was used to investigate plasma metabolic differences in cows that had clinical ketosis (CK, n=22), subclinical ketosis (SK, n=32), or were clinically normal controls (NC, n=22). The endogenous plasma metabolome was measured by chemical derivatization followed by GC/MS, which led to the detection of 267 variables. A two-sample t-test of 30, 32, and 13 metabolites showed statistically significant differences between SK and NC, CK and NC, and CK and SK, respectively. Orthogonal signal correction-partial least-square discriminant analysis (OPLS-DA) revealed that the metabolic patterns of both CK and SK were mostly similar, with the exception of a few differences. The development of CK and SK involved disturbances in many metabolic pathways, mainly including fatty acid metabolism, amino acid metabolism, glycolysis, gluconeogenesis, and the pentose phosphate pathway. A diagnostic model arbitrary two groups was constructed using OPLS-DA and receiver-operator characteristic curves (ROC). Multivariate statistical diagnostics yielded the 19 potential biomarkers for SK and NC, 31 for CK and NC, and 8 for CK and SK with area under the curve (AUC) values. Our results showed the potential biomarkers from CK, SK, and NC, including carbohydrates, fatty acids, amino acids, even sitosterol and vitamin E isomers, etc. 2-piperidinecarboxylic acid and cis-9-hexadecenoic acid were closely associated with metabolic perturbations in ketosis as Glc, BHBA and NEFA for dealing with metabolic disturbances of ketosis in clinical practice. However, further research is needed to explain changes of 2,3,4-trihydroxybutyric acid, 3,4-dihydroxybutyric acid, α-aminobutyric acid, methylmalonic acid, sitosterol and α-tocopherol in CK and SK, and to reveal differences between CK and SK. Our

  14. Extending the range of compounds amenable for gas chromatography-mass spectrometric analysis.

    Science.gov (United States)

    Fialkov, Alexander B; Gordin, Alexander; Amirav, Aviv

    2003-04-04

    Gas chromatography-mass spectrometry (GC-MS) suffers from a major limitation in that an expanding number of thermally labile or low volatility compounds of interest are not amenable for analysis. We found that the elution temperatures of compounds from GC can be significantly lowered by reducing the column length, increasing the carrier gas flow rate, reducing the capillary column film thickness and lowering the temperature programming rate. Pyrene is eluted at 287 degrees C in standard GC-MS with a 30 m x 0.25 mm I.D. column with 1-microm DB5ms film and 1-ml/min He column flow rate. In contrast, pyrene is eluted at 79 degrees C in our "Supersonic GC-MS" system using a 1 m x 0.25 mm I.D. column with 0.1-microm DB5ms film and 100-ml/min He column flow rate. A simple model has been invoked to explain the significantly (up to 208 degrees C) lower elution temperatures observed. According to this model, every halving of the temperature programming rate, or number of separation plates (either through increased flow rate or due to reduced column length), results in approximately 20 degrees C lower elution temperature. These considerably lower elution temperatures enable the analysis of an extended range of thermally labile and low volatility compounds, that otherwise could not be analyzed by standard GC-MS. We demonstrate the analysis of large polycyclic aromatic hydrocarbons (PAHs) such as decacyclene with ten fused rings, well above the current GC limit of PAHs with six rings. Even a metalloporphirin such as magnesiumoctaethylporphin was easily analyzed with elution temperatures below 300 degrees C. Furthermore, a range of thermally labile compounds were analyzed including carbamates such as methomyl, aldicarb, aldicarbsulfone and oxamyl, explosives such as pentaerythritol tetranitrate, Tetryl and HMX, and drugs such as reserpine (608 a.m.u.). Supersonic GC-MS was used, based on the coupling of a supersonic molecular beam (SMB) inlet and ion sources with a bench

  15. Importance of optimizing chromatographic conditions and mass spectrometric parameters for supercritical fluid chromatography/mass spectrometry.

    Science.gov (United States)

    Fujito, Yuka; Hayakawa, Yoshihiro; Izumi, Yoshihiro; Bamba, Takeshi

    2017-07-28

    Supercritical fluid chromatography/mass spectrometry (SFC/MS) has great potential in high-throughput and the simultaneous analysis of a wide variety of compounds, and it has been widely used in recent years. The use of MS for detection provides the advantages of high sensitivity and high selectivity. However, the sensitivity of MS detection depends on the chromatographic conditions and MS parameters. Thus, optimization of MS parameters corresponding to the SFC condition is mandatory for maximizing performance when connecting SFC to MS. The aim of this study was to reveal a way to decide the optimum composition of the mobile phase and the flow rate of the make-up solvent for MS detection in a wide range of compounds. Additionally, we also showed the basic concept for determination of the optimum values of the MS parameters focusing on the MS detection sensitivity in SFC/MS analysis. To verify the versatility of these findings, a total of 441 pesticides with a wide polarity range (logP ow from -4.21 to 7.70) and pKa (acidic, neutral and basic). In this study, a new SFC-MS interface was used, which can transfer the entire volume of eluate into the MS by directly coupling the SFC with the MS. This enabled us to compare the sensitivity or optimum MS parameters for MS detection between LC/MS and SFC/MS for the same sample volume introduced into the MS. As a result, it was found that the optimum values of some MS parameters were completely different from those of LC/MS, and that SFC/MS-specific optimization of the analytical conditions is required. Lastly, we evaluated the sensitivity of SFC/MS using fully optimized analytical conditions. As a result, we confirmed that SFC/MS showed much higher sensitivity than LC/MS when the analytical conditions were fully optimized for SFC/MS; and the high sensitivity also increase the number of the compounds that can be detected with good repeatability in real sample analysis. This result indicates that SFC/MS has potential for

  16. [Simultaneous determination of five alkaloids in Niuhuang Shangqing Tablets by micellar electrokinetic chromatography-mass spectrometry using laurel acyl malic acid ester].

    Science.gov (United States)

    Hu, Mengdi; Su, Di; Fan, Xiaosu; Yu, Jianhua; Xu, Yuanjin

    2012-12-01

    A micellar electrokinetic chromatography-mass spectrometric method based on laurel acyl malic acid ester (LMAE) for the separation and determination of coptisine, berberine, jatrorrhizine, phellodendrine and ligustrazine in Niuhuang Shangqing Tablets was established. The baseline separation of the five compounds was attained within 18 min by an uncoated capillary (88 cm x 50 microm) on the operating voltage of 25 kV using 7.5 mmol/L LMAE-15 mmol/L ammonia-50 mmol/L ammonium acetate mixture (pH = 7.0) containing 12.5% (v/v) acetonitrile as the electrophoretic medium and 50% 2-propanol aqueous solution (containing 3 mmol/L acetic acid) as the sheath liquid. The peak area of each component to its concentration showed a good linear relationship. The relative standard deviations of migration times and peak areas of the five components were less than 5% and the recoveries were between 96.0% and 105%. The developed method is simple, rapid, accurate and is suitable for the routine analysis of the five alkaloid components in Niuhuang Shangqing Tablets.

  17. Determination of tributyltin in environmental water matrices using stir bar sorptive extraction with in-situ derivatisation and large volume injection-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Neng, N R; Santalla, R P; Nogueira, J M F

    2014-08-01

    Stir bar sorptive extraction with in-situ derivatization using sodium tetrahydridoborate (NaBH4) followed by liquid desorption and large volume injection-gas chromatography-mass spectrometry detection under the selected ion monitoring mode (SBSE(NaBH4)in-situ-LD/LVI-GC-MS(SIM)) was successfully developed for the determination of tributyltin (TBT) in environmental water matrices. NaBH4 proved to be an effective and easy in-situ speciation agent for TBT in aqueous media, allowing the formation of adducts with enough stability and suitable polarity for SBSE analysis. Assays performed on water samples spiked at the 10.0μg/L, yielded convenient recoveries (68.2±3.0%), showed good accuracy, suitable precision (RSD<9.0%), low detection limits (23ng/L) and excellent linear dynamic range (r(2)=0.9999) from 0.1 to 170.0µg/L, under optimized experimental conditions. By using the standard addition method, the application of the present methodology to real surface water samples allowed very good performance at the trace level. The proposed methodology proved to be a feasible alternative for routine quality control analysis, easy to implement, reliable and sensitive to monitor TBT in environmental water matrices. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Resolution 197/012. It replaces the wording of Annex III of the Regulation of Technical Specifications for Quality of Liquid Fuels, approved by Resolution of the URSEA 150/008

    International Nuclear Information System (INIS)

    2012-01-01

    This resolution is about modifications made in the regulation of technical specifications in the quality of liquid fuels, approved by Resolution of the URSEA 150/008. These modifications concern to the Especial Oil gas

  19. Probing spatial locality in ionic liquids with the grand canonical adaptive resolution molecular dynamics technique

    Science.gov (United States)

    Shadrack Jabes, B.; Krekeler, C.; Klein, R.; Delle Site, L.

    2018-05-01

    We employ the Grand Canonical Adaptive Resolution Simulation (GC-AdResS) molecular dynamics technique to test the spatial locality of the 1-ethyl 3-methyl imidazolium chloride liquid. In GC-AdResS, atomistic details are kept only in an open sub-region of the system while the environment is treated at coarse-grained level; thus, if spatial quantities calculated in such a sub-region agree with the equivalent quantities calculated in a full atomistic simulation, then the atomistic degrees of freedom outside the sub-region play a negligible role. The size of the sub-region fixes the degree of spatial locality of a certain quantity. We show that even for sub-regions whose radius corresponds to the size of a few molecules, spatial properties are reasonably reproduced thus suggesting a higher degree of spatial locality, a hypothesis put forward also by other researchers and that seems to play an important role for the characterization of fundamental properties of a large class of ionic liquids.

  20. [Feasibility investigation of hydrogen instead of helium as carrier gas in the determination of five organophosphorus pesticides by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Liu, Zhenxue; Zhou, Shixue

    2015-01-01

    Helium is almost the only choosable carrier gas used in gas chromatography-mass spectrometry (GC-MS). A mixed standard solution of five organophosphorus pesticides was analyzed by using GC-MS, and hydrogen or helium as carrier gas, so as to study the feasibility of hydrogen instead of helium as carrier gas for the determination of organophosphorus pesticides. Combining a mass spectrum database built by ourselves, the results were deconvolved and identified by Automated Mass Spectral Deconvolution & Identification System (AMDIS32), a software belonging to the workstation of the instrument. Then, the statistical software, IBM SPSS Statistics 19.0 was used for the clustering analysis of the data. The results indicated that when hydrogen was used as carrier gas, the peaks of the pesticides detected were slightly earlier than those when helium used as carrier gas, but the resolutions of the chromatographic peaks were lower, and the fraction good indices (Frac. Good) were lower, too. When hydrogen was used as carrier gas, the signals of the pesticides were unstable, the measuring accuracies of the pesticides were reduced too, and even more, some compounds were undetectable. Therefore, considering the measuring accuracy, the signal stability, and the safety, etc., hydrogen should be cautiously used as carrier gas in the determination of organophosphorus pesticides by GC-MS.

  1. Some rules to improve the energy resolution in alpha liquid scintillation with beta rejection

    CERN Document Server

    Aupiais, J; Dacheux, N

    2003-01-01

    Two common scintillating mixtures dedicated to alpha measurements by means of alpha liquid scintillation with pulse shape discrimination were tested: the di-isopropylnaphthalene - based and the toluene-based solvents containing the commercial cocktails Ultima Gold AB trademark and Alphaex trademark. We show the possibility to enhance the resolution up to 200% by using no-water miscible cocktails and by reducing the optical path. Under these conditions, the resolution of about 200 keV can be obtained either by the Tri Carb sup T sup M or by the Perals sup T sup M spectrometers. The time responses, e.g., the time required for a complete energy transfer between the initial interaction alpha particle-solvent and the final fluorescence of the organic scintillator, have been compared. Both cocktails present similar behavior. According to the Foerster theory, about 6-10 ns are required to complete the energy transfer. For both apparatus, the detection limits were determined for alpha emitters. The sensitivity of the...

  2. Determination of naphthenic acid profile in Ghana's Jubilee Oil using gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Osuteye, I.

    2015-01-01

    Crude oil is the life-blood of the global economy. Its importance stems from the fact that it is a base product for a wide variety of goods [Drugs, Plastics, Liquefied Petroleum Gas (LPG)]. The oil discovery (over 3 billion barrel reserves in hydrocarbon and gas), about 60 km offshore between the Deepwater Tano and Cape Three Points Block in South western Ghana is a valuable natural asset and it has the potential of boosting the Ghanaian economy. During petroleum processing, various waste products are generated. One of such products is Naphthenic acids (NA). Naphthenic acids are organic acids naturally occurring in crude oil and a constituent of waste associated with oil refinery. Naphthenic acids serve as biomarkers for identification of the source of crude oil. The presence of Naphthenic acid in the aquatic environment causes toxic effects due to their weak biodegradable nature; the toxicity of Naphthenic acids depends on the class of Naphthenic acids present in the crude oil. The study assessed the profile of Naphthenic acids in Ghana’s Jubilee crude oil using Low Resolution Electron Impact – Gas Chromatography Mass Spectrometry (LREI-GCMS) after isolation of Naphthenic acids in the Jubilee oil by a modified Kupchan’s Partitioning Process. The Mass Spectrometric (MS) Work Station Software was used for the identification of the Naphthenic acids present in the Jubilee crude oil. The quality of the Jubilee oil was also evaluated through the use of some key physico-chemical parameters [Total Acid Number (TAN), Sulphur Content, Viscosity, Pour Point, Flashpoint, Water Content and Densities] based on the American Standards for Testing and Materials (ASTM, 2007). The Total Acid Number was determined by Colorimetric Titration (ASTM D974); Sulphur Content by X-ray Fluorescent Spectrometry (ASTM D4294); Pour Point by the use of the SETA cloud and Pour Point Refrigerator Technique (ASTM D97); Viscosity by Gravity Timed Method (ASTM D445); Density by the Hydrometer

  3. The use of stable isotopes and gas chromatography/mass spectrometry in the identification of steroid metabolites in the equine

    International Nuclear Information System (INIS)

    Houghton, E.; Dumasia, M.C.; Teale, P.; Smith, S.J.; Cox, J.; Marshall, D.; Gower, D.B.

    1990-01-01

    Stable isotope gas chromatography/mass spectrometry has been used successfully in the elucidation of structures of urinary steroid metabolites in the horse and in the identification of metabolites isolated from in vivo perfusion and in vitro incubation studies using equine tissue preparations. Deuterium-labeled steroids, testosterone, dehydroepiandrosterone, and 5-androstene-3 beta,17 beta-diol have been synthesized by base-catalyzed isotope exchange methods and the products characterized by gas chromatography/mass spectrometry. [16,16(-2)H2]Dehydroepiandrosterone (plus radiolabeled dehydroepiandrosterone) was perfused into a testicular artery of a pony stallion and was shown to be metabolized into 2H2-labeled testosterone, 4-androstenedione, isomers of 5-androstene-3,17-diol, 19-hydroxytestosterone, and 19-hydroxy-4-androstenedione. In further studies, equine testicular minces have been incubated with 2H2-labeled and radiolabeled dehydroepiandrosterone and 5-androstene-3 beta, 17 beta-diol. The metabolites, whose identity was confirmed by stable isotope gas chromatography/mass spectrometry, proved the interconversion of the two substrates, as well as formation of testosterone and 4-androstenedione. The aromatization of dehydroepiandrosterone was also confirmed, together with the formation of an isomer of 5(10)-estrene-3,17-diol from both substrates showing 19-demethylation without concomitant aromatization. In studies of the feto-placental unit, the allantochorion was shown to aromatize [2H5]testosterone to [2H4]estradiol, the loss of one 2H from the substrate being consistent with aromatization of the A ring. The formation of 6-hydroxyestradiol was also confirmed in this study. The same technique has been valuable in determining the structure of two metabolites of nandrolone isolated from horse urine

  4. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were

  5. [Specific detection of urinary sympathomimetic amines for control of anti-doping by gas chromatography-mass spectroscopy].

    Science.gov (United States)

    Franceschini, A; Duthel, J M; Vallon, J J

    1991-03-22

    A specific, sensitive and reliable gas chromatography-mass spectrometry (GC-MS) technique for detection of sympathomimetic amines following urinary extraction is proposed. Amphetamine, phentermine, ephedrine, mephenorex, methylphenidate, benzphetamine, clobenzorex and internal standard (fenfluramine) are extracted from urines at pH 7.0 using elution by chloroform-isopropanol on C18 cartridges. Derivatization followed by GC-MS analysis allows identification of these drugs founded on relative retention times and mass spectra. The quantitation limit for derivatizable drugs was found to be 200 ng/ml and 500 ng/ml for underivatizable drugs.

  6. Development of a Method for Rapid Determination of Morpholine in Juices and Drugs by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Mengsi Cao

    2018-01-01

    Full Text Available A reliable derivatization method has been developed to detect and quantify morpholine in apple juices and ibuprofen with gas chromatography-mass spectrometry. Morpholine can react with sodium nitrite under acidic condition to produce stable and volatile N-nitrosomorpholine derivative. In this experiment, various factors affecting the derivatization and extraction process were optimized, including volume and concentration of hydrochloric acid, quantity of sodium nitrite, derivatization temperature, derivatization time, extraction reagents, and extraction time. The derivative was extracted with dichloromethane and determined by gas chromatography-mass spectrometry. The linearity range of morpholine was 10–500 μg·L−1 with good correlation, and limits of detection (LOD and limits of quantification (LOQ were 7.3 μg·L−1 and 24.4 μg·L−1, respectively. Low, medium, and high concentrations of morpholine were added in apple juices and ibuprofen samples to evaluate standard recovery rate and relative standard deviation. The spiked recovery rate ranged from 94.3% to 109.0%, and the intraday repeatability and interday reproducibility were 2.0%–4.4% and 3.3%–7.0%, respectively. The developed method has good accuracy and precision. This quantitative method for morpholine is simple, sensitive, rapid, and low cost and can successfully be applied to analyze the residual morpholine in apple juices and drug samples.

  7. A single-run liquid chromatography mass spectrometry method to quantify neuroactive kynurenine pathway metabolites in rat plasma.

    Science.gov (United States)

    Orsatti, Laura; Speziale, Roberto; Orsale, Maria Vittoria; Caretti, Fulvia; Veneziano, Maria; Zini, Matteo; Monteagudo, Edith; Lyons, Kathryn; Beconi, Maria; Chan, Kelvin; Herbst, Todd; Toledo-Sherman, Leticia; Munoz-Sanjuan, Ignacio; Bonelli, Fabio; Dominguez, Celia

    2015-03-25

    Neuroactive metabolites in the kynurenine pathway of tryptophan catabolism are associated with neurodegenerative disorders. Tryptophan is transported across the blood-brain barrier and converted via the kynurenine pathway to N-formyl-L-kynurenine, which is further degraded to L-kynurenine. This metabolite can then generate a group of metabolites called kynurenines, most of which have neuroactive properties. The association of tryptophan catabolic pathway alterations with various central nervous system (CNS) pathologies has raised interest in analytical methods to accurately quantify kynurenines in body fluids. We here describe a rapid and sensitive reverse-phase HPLC-MS/MS method to quantify L-kynurenine (KYN), kynurenic acid (KYNA), 3-hydroxy-L-kynurenine (3HK) and anthranilic acid (AA) in rat plasma. Our goal was to quantify these metabolites in a single run; given their different physico-chemical properties, major efforts were devoted to develop a chromatography suitable for all metabolites that involves plasma protein precipitation with acetonitrile followed by chromatographic separation by C18 RP chromatography, detected by electrospray mass spectrometry. Quantitation range was 0.098-100 ng/ml for 3HK, 9.8-20,000 ng/ml for KYN, 0.49-1000 ng/ml for KYNA and AA. The method was linear (r>0.9963) and validation parameters were within acceptance range (calibration standards and QC accuracy within ±30%). Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Enzyme-assisted extraction and liquid chromatography mass spectrometry for the determination of arsenic species in chicken meat.

    Science.gov (United States)

    Liu, Qingqing; Peng, Hanyong; Lu, Xiufen; Le, X Chris

    2015-08-12

    Chicken is the most consumed meat in North America. Concentrations of arsenic in chicken range from μg kg(-1) to mg kg(-1). However, little is known about the speciation of arsenic in chicken meat. The objective of this research was to develop a method enabling determination of arsenic species in chicken breast muscle. We report here enzyme-enhanced extraction of arsenic species from chicken meat, separation using anion exchange chromatography (HPLC), and simultaneous detection with both inductively coupled plasma mass spectrometry (ICPMS) and electrospray ionization tandem mass spectrometry (ESIMS). We compared the extraction of arsenic species using several proteolytic enzymes: bromelain, papain, pepsin, proteinase K, and trypsin. With the use of papain-assisted extraction, 10 arsenic species were extracted and detected, as compared to 8 detectable arsenic species in the water/methanol extract. The overall extraction efficiency was also improved using a combination of ultrasonication and papain digestion, as compared to the conventional water/methanol extraction. Detection limits were in the range of 1.0-1.8 μg arsenic per kg chicken breast meat (dry weight) for seven arsenic species: arsenobetaine (AsB), inorganic arsenite (As(III)), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), inorganic arsenate (As(V)), 3-nitro-4-hydroxyphenylarsonic acid (Roxarsone), and N-acetyl-4-hydroxy-m-arsanilic acid (NAHAA). Analysis of breast meat samples from six chickens receiving feed containing Roxarsone showed the presence of (mean±standard deviation μg kg(-1)) AsB (107±4), As(III) (113±7), As(V) (7±2), MMA (51±5), DMA (64±6), Roxarsone (18±1), and four unidentified arsenic species (approximate concentration 1-10 μg kg(-1)). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Lipidome and metabolome analysis of fresh tobacco leaves in different geographical regions using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Lili; Lu, Xin; Zhao, Jieyu; Zhang, Junjie; Zhao, Yanni; Zhao, Chunxia; Xu, Guowang

    2015-07-01

    The combination of the lipidome and the metabolome can provide much more information in plant metabolomics studies. A method for the simultaneous extraction of the lipidome and the metabolome of fresh tobacco leaves was developed. Method validation was performed on the basis of the optimal ratio of methanol to methyl tert-butyl ether to water (37:45:68) from the design of experiments. Good repeatability was obtained. We found that 92.2% and 91.6% of the peaks for the lipidome and the metabolome were within a relative standard deviation of 20%, accounting for 94.6% and 94.6% of the total abundance, respectively. The intraday and interday precisions were also satisfactory. A total of 230 metabolites, including 129 lipids, were identified. Significant differences were found in lipidomic and metabolomic profiles of fresh tobacco leaves in different geographical regions. Highly unsaturated galactolipids, phosphatidylethanolamines, predominant phosphatidylcholines, most of the polyphenols, amino acids, and polyamines had a higher content in Yunnan province, and low-unsaturation-degree galactolipids, triacylglycerols, glucosylceramides with trihydroxy long-chain bases, acylated sterol glucosides, and some organic acids were more abundant in Henan province. Correlation analysis between differential metabolites and climatic factors indicated the vital importance of temperature. The fatty acid unsaturation degree of galactolipids could be influenced by temperature. Accumulation of polyphenols and decreases in the ratios of stigmasterols to sitosterols and glucosylstigmasterols to glucosylsitosterols were also correlated with lower temperature in Yunnan province. Furthermore, lipids were more sensitive to climatic variations than other metabolites.

  10. Identification of plant proteins in adulterated skimmed milk powder by high-performance liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Luykx, D.M.A.M.; Cordewener, J.H.G.; Ferranti, P.; Frankhuizen, R.; Bremer, M.G.E.G.; Hooijerink, H.; America, A.H.P.

    2007-01-01

    The EU subsidises the use of skimmed-milk powder (SMP) in compound feeding stuffs. There are indications of falsified SMP content due to the addition of plant proteins. These proteins are not allowed in SMP and cannot be identified by the official reference method. Since soy and pea proteins are

  11. Development of a liquid chromatography/mass spectrometry assay for the bacterial transglycosylation reaction through measurement of Lipid II

    NARCIS (Netherlands)

    Blanchaert, Bart; Wyseure, Tine; Breukink, Eefjan; Adams, Erwin; Declerck, Paul; Van Schepdael, Ann

    2015-01-01

    Transglycosylation is the second to last step in the production of bacterial peptidoglycan. It is catalyzed by a transglycosylation site in class A penicillin-binding proteins (PBPs) or monofunctional glycosyl transferases. Several potential inhibitors have been suggested and need to be tested for

  12. Liquid chromatography/mass spectrometry analysis of branched fructans produced in vitro with C-13-labeled substrates

    DEFF Research Database (Denmark)

    Verspreet, Joran; Hansen, Anders Holmgaard; Dornez, Emmie

    2014-01-01

    RATIONALE:Fructans are carbohydrates predominantly based on fructose which are generally considered to be soluble dietary fibers with health-promoting properties. It is known that the nutritional properties of fructans are affected by their structure. This study focused on structural determinatio...

  13. Study of human lung elastin degradation by different elastases using high-performance liquid chromatography/mass spectrometry

    NARCIS (Netherlands)

    Barroso, Begona; Abello, Nicolas; Bischoff, Rainer

    2006-01-01

    Elastin is a structural insoluble protein which gives elasticity to tissues and organs. Although its hydrophobic and highly cross-linked nature makes it a very durable polymer, degradation of elastin in relation with several pathological conditions, such as pulmonary emphysema, has been documented.

  14. Large-scale retrospective evaluation of regulated liquid chromatography-mass spectrometry bioanalysis projects using different total error approaches.

    Science.gov (United States)

    Tan, Aimin; Saffaj, Taoufiq; Musuku, Adrien; Awaiye, Kayode; Ihssane, Bouchaib; Jhilal, Fayçal; Sosse, Saad Alaoui; Trabelsi, Fethi

    2015-03-01

    The current approach in regulated LC-MS bioanalysis, which evaluates the precision and trueness of an assay separately, has long been criticized for inadequate balancing of lab-customer risks. Accordingly, different total error approaches have been proposed. The aims of this research were to evaluate the aforementioned risks in reality and the difference among four common total error approaches (β-expectation, β-content, uncertainty, and risk profile) through retrospective analysis of regulated LC-MS projects. Twenty-eight projects (14 validations and 14 productions) were randomly selected from two GLP bioanalytical laboratories, which represent a wide variety of assays. The results show that the risk of accepting unacceptable batches did exist with the current approach (9% and 4% of the evaluated QC levels failed for validation and production, respectively). The fact that the risk was not wide-spread was only because the precision and bias of modern LC-MS assays are usually much better than the minimum regulatory requirements. Despite minor differences in magnitude, very similar accuracy profiles and/or conclusions were obtained from the four different total error approaches. High correlation was even observed in the width of bias intervals. For example, the mean width of SFSTP's β-expectation is 1.10-fold (CV=7.6%) of that of Saffaj-Ihssane's uncertainty approach, while the latter is 1.13-fold (CV=6.0%) of that of Hoffman-Kringle's β-content approach. To conclude, the risk of accepting unacceptable batches was real with the current approach, suggesting that total error approaches should be used instead. Moreover, any of the four total error approaches may be used because of their overall similarity. Lastly, the difficulties/obstacles associated with the application of total error approaches in routine analysis and their desirable future improvements are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Rapid enzymatic hydrolysis of masked deoxynivalenol and zearalenone prior to liquid chromatography mass spectrometry or immunoassay analysis

    Czech Academy of Sciences Publication Activity Database

    Nielen, M. F. V.; Weijers, C. A. G. M.; Peters, J.; Weignerová, Lenka; Zuilhof, H.; Franssen, M. C. R.

    2014-01-01

    Roč. 7, č. 2 (2014), s. 107-113 ISSN 1875-0710 Institutional support: RVO:61388971 Keywords : masked mycotoxins * enzymatic hydrolysis * 1,3-beta-glucanase Subject RIV: CE - Biochemistry Impact factor: 2.157, year: 2014

  16. Determination of flumazenil in serum by liquid chromatography-mass spectrometry: Application to kinetics study in acute diazepam overdose

    OpenAIRE

    Đorđević Snežana; Jović-Stošić Jasmina; Kilibarda Vesna; Šegrt Zoran; Perković-Vukčević Nataša

    2016-01-01

    Backgound/Aim. Flumazenil is benzodiazepine receptor antagonist. It has been studied for a various indications, including reversal of sedation after surgery or diagnostic procedures, awakening of comatose patients in benzodiazepine overdose, or for symptomatic treatment of hepatic encephalopathy. Some drugs, like theophylline, may prolong its elimination half-life. Considering the long half-life of diazepam and its metabolites, concomitant use of theophylli...

  17. Analysis of Zolpidem in Postmortem Fluids and Tissues Using Ultra-Performance Liquid Chromatography-Mass Spectrometry

    Science.gov (United States)

    2014-02-01

    in postmortem fluids and tissues. 17. Key Words 18. Distribution Statement Forensic Toxicology , Zolpidem, Ambien, Postmortem Distribution, LC/MS/MS...Institute (CAMI) toxicology database identified 10 fatalities from separate avia- tion accidents that were reported positive for zolpidem and also...Sample Selection and Storage A search of the CAMI toxicology database (ToxFLO, DiscoverSoft Development, LLC; Oklahoma City, OK) identi- fied 10

  18. Simultaneous determination of levocetirizine and pseudoephedrine in dog plasma by liquid chromatography-mass spectrometry in the presence of dextrocetirizine.

    Science.gov (United States)

    Ryu, Jae Kuk; Yoo, Sun Dong

    2012-01-01

    This study describes the development of a rapid and sensitive LC-ESI-MS assay for simultaneous enantioselective determination of levocetirizine and pseudoephedrine in dog plasma in the presence of dextrocetirizine. Separations were achieved on an Ultron ES-OVM chiral column using the mobile phase consisting of 10 mM aqueous NH4OAc (pH 6.6) and acetonitrile (9:1 v/v). The retention times of pseudoephedrine, dextrocetirizine, levocetirizine and diazepam (internal standard) were 5.2, 8.3, 9.6 and 11.6 min, respectively, and the total run time was less than 15 min. The assay was validated to demonstrate the linearity, accuracy and precision, recovery and stability. The calibration curves were linear over the concentration range from 1 - 200 ng/mL for levocetirizine and from 5 - 1000 ng/mL for pseudoephedrine. The developed assay was successfully applied to a pharmacokinetic study after oral administration of the racemic cetirizine (0.5 mg/kg, or 0.25 mg/kg as levocetirizine) and pseudoephedrine (12 mg/kg) in the dog. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.

  19. A liquid chromatography-mass spectrometric method for the detection of cyclic beta-amino fatty acid lipopeptides.

    Czech Academy of Sciences Publication Activity Database

    Urajová, P.; Hájek, Jan; Wahlsten, M.; Jokela, J.; Galica, T.; Fewer, D.P.; Kust, Andreja; Zapomělová; Kozlíková, Eliška; Delawská, K.; Sivonen, K.; Kopecký, J.; Hrouzek, P.

    2016-01-01

    Roč. 1438, March (2016), s. 76-83 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA14-18067S; GA ČR(CZ) GA16-09381S Institutional support: RVO:60077344 Keywords : lipopeptides * bacteria * cyanobacteria * LC-HRMS * fatty acid * peptide Subject RIV: EE - Microbiology, Virology Impact factor: 3.981, year: 2016

  20. A liquid chromatography-mass spectrometric method for the detection of cyclic beta-amino fatty acid lipopeptides

    Czech Academy of Sciences Publication Activity Database

    Urajová, Petra; Hájek, Jan; Wahlsten, M.; Jokela, J.; Galica, Tomáš; Fewer, D.P.; Kust, Andreja; Zapomělová-Kozlíková, E.; Delawská, Kateřina; Sivonen, K.; Kopecký, Jiří; Hrouzek, Pavel

    2016-01-01

    Roč. 1438, MARCH 18 (2016), s. 76-83 ISSN 0021-9673 R&D Projects: GA MŠk(CZ) LO1416; GA ČR(CZ) GA14-18067S; GA ČR(CZ) GA16-09381S Institutional support: RVO:61388971 Keywords : Lipopeptides * Bacteria * Cyanobacteria Subject RIV: EE - Microbiology, Virology Impact factor: 3.981, year: 2016

  1. Novel calibration model maintenance strategy for solving the signal instability in quantitative liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Hai-Li; Chen, Zeng-Ping; Song, Mi; Chen, Yao; Yu, Ru-Qin

    2014-04-18

    In this contribution, a multiplicative effects model with a parameter accounting for the variations in overall sensitivity over time was proposed to reduce the effects of signal instability on quantitative results of LC-MS/MS. This method allows the use of calibration models constructed from large standard sets without having to repeat their measurement even though variations occur in sensitivity and baseline signal intensity. The performance of the proposed method was tested on two proof-of-concept model systems: the determination of the target peptide in two sets of peptide digests mixtures and the quantification of melamine and metronidazole in two sets of milk powder samples. Experimental results confirmed that multiplicative effects model could provide quite satisfactory concentration predictions for both systems with average relative predictive error values far lower than the corresponding values of various models investigated in this paper. Considering its capability in solving the problem of signal instability across samples and over time in LC-MS/MS assays and its implementation simplicity, it is expected that the multiplicative effects model can be developed and extended in many application areas such as the quantification of specific protein in cells and human plasma and other complex systems. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Analysis of zolpidem in postmortem fluids and tissues using ultra-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    2014-02-01

    Zolpidem is a nonbenzodiazepine sedative hypnotic drug used for the short-term treatment of insomnia. Its : use is common and wide-spread. While quite effective in producing sedation, zolpidem has potentially : hazardous side effects when put in the ...

  3. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method

    DEFF Research Database (Denmark)

    De Angelis, Meri; Giesert, Florian; Finan, Brian

    2016-01-01

    ). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method the instrumental calibration curves were constructed from 0 to 100pgμL(-1) and all of them showed good linearity (r(2)>0.99...

  4. Batch-processing of imaging or liquid-chromatography mass spectrometry datasets and De Novo sequencing of polyketide siderophores

    Czech Academy of Sciences Publication Activity Database

    Novák, Jiří; Sokolová, Lucie; Lemr, Karel; Pluháček, Tomáš; Palyzová, Andrea; Havlíček, Vladimír

    2017-01-01

    Roč. 1865, č. 7 (2017), s. 768-775 ISSN 1570-9639 R&D Projects: GA ČR(CZ) GA16-20229S; GA MŠk(CZ) LO1509 Institutional support: RVO:61388971 Keywords : Mass spectrometry imaging * De novo sequencing * Siderophores Subject RIV: EE - Microbiology, Virology OBOR OECD: Microbiology Impact factor: 2.773, year: 2016

  5. Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography-mass spectrometry.

    Science.gov (United States)

    Akbal, Laura; Hopfgartner, Gérard

    2017-09-29

    In supercritical fluid chromatography coupled to atmospheric pressure ionization mass spectrometry (SFC-MS), the use of a make-up post-column is almost mandatory to avoid analyte precipitation, especially when using low percentage of modifier (supercritical conditions (1mL/min 40°C, 150bar) to gaseous state (room temperature, atmospheric pressure), the CO 2 expands around 430 times, contributing to almost 5% of the nebulizing process. In positive mode, the presence of ammonium ions either in the mobile phase or in the make-up did significantly increase the MS signal, even at basic apparent pH. The ionization performance of electrospray is influenced by the acidic buffer power of the carbon dioxide, and was found to be restricted in the apparent pH range of 3.8-7.2 in the various conditions investigated. This may challenge sensitive detection in negative mode, as illustrated for bosentan. The use of DMSO as make-up additive (up to 30%) showed a simplification of the full scan spectrum regarding the adducts. Finally, the optimization of make-up composition leads to an enhancement up to a factor of 69 on the electrospray MS response signal, for the SFC-SRM/MS analysis of HIV protease inhibitors in plasma extracted from Dried Plasma Spots. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Analytical method by high resolution liquid chromatography for the determination of carbamazepine in human plasma

    International Nuclear Information System (INIS)

    Jimenez Aleman, Narda M; Calero Carbonell, Jorge E; Padron Yaquis, Alejandro S; Izquierdo Lozano, Julio C

    2007-01-01

    One of the requirements to develop the studies of bioavailability and bioequivalence is to have analytic methodologies validated for the work with samples in biological fluids. A method was developed by high resolution liquid chromatography for the determination of carbamazepine in human plasma. A mixture of hydrogen phosphate of sodium: acetonitrile (65:35) adjusted to pH= 3.3 with phosphoric acid, flow of 1.2 mL/min and ultraviolet detection at 210 nm, was used as mobile phase. Propylparabene was used as an internal standard. According to the established regulations for the validation of the methods in biological fluids, the following parameters were studied: stability of the samples, lineality, specificity, precision, accuracy and limit of detection and quantification. The method proved to be specific and sensitive with a detection and quantification limit of 0.9 and 1.0 ng, respectively. The method was lineal, precise and exact in the range of concentrations of 1. 07 at 12.67 μg/mL. The mean recovery was not statistically different from 100.0 %. The analito in the proposed biological matrix remained in the studied period. The methodology described in this work is applied in our case to the study that evaluates the bioavailability and bioequivalence of a Cuban formulation of carbamazepine in healthy volunteers. (Author)

  7. A high-resolution tracking hodoscope based on capillary layers filled with liquid scintillator

    CERN Document Server

    Bay, A; Bruski, N; Buontempo, S; Currat, C; D'Ambrosio, N; Ekimov, A V; Ereditato, A; Fabre, Jean-Paul; Fanti, V; Frekers, D; Frenkel, A; Golovkin, S V; Govorun, V N; Harrison, K; Koppenburg, P; Kozarenko, E N; Kreslo, I E; Liberti, B; Martellotti, G; Medvedkov, A M; Mondardini, M R; Penso, G; Siegmund, W P; Vasilchenko, V G; Vilain, P; Wilquet, G; Winter, Klaus; Wörtche, H J

    2001-01-01

    Results are given on tests of a high-resolution tracking hodoscope based on layers of \\hbox{26-$\\mu$m-bore} glass capillaries filled with organic liquid scintillator (1-methylnaphthalene doped with R39). The detector prototype consisted of three 2-mm-thick parallel layers, with surface areas of $2.1 \\times 21$~cm$^2$. The layers had a centre-to-centre spacing of 6~mm, and were read by an optoelectronic chain comprising two electrostatically focused image intensifiers and an Electron-Bombarded Charge-Coupled Device (EBCCD). Tracks of cosmic-ray particles were recorded and analysed. The observed hit density was 6.6~hits/mm for particles crossing the layers perpendicularly, at a distance of 1~cm from the capillaries' readout end, and 4.2~hits/mm for particles at a distance of 20~cm. A track segment reconstructed in a single layer had an rms residual of $\\sim$~20~$\\mu$m, and allowed determination of the track position in a neighbouring layer with a precision of $\\sim$~170~$\\mu$m. This latter value corresponded to...

  8. Analyse chronometrique intersexes de la resolution de la tache d'horizontalite des liquides

    Science.gov (United States)

    Berthiaume, Francois

    D'abondantes recherches ont demontre que la reussite a la tache d'horizontalite des liquides est en moyenne plus elevee chez les individus de sexe masculin que chez ceux de sexe feminin. Deux facteurs principaux ont ete proposes: il s'agit de la connaissance du principe physique de l'invariance de l'orientation des liquides et de certaines habiletes perceptives d'ordre visuel. Le but de la presente recherche est d'etablir la duree detaillee de la resolution de la tache d'horizontalite des liquides chez 185 filles et 180 garcons, ages de 15 a 19 ans et repartis en 8 groupes. Dans une version informatisee, le premier groupe trace la position de la surface de l'eau a l'interieur d'un contenant dans diverses inclinaisons et le deuxieme evalue si l'orientation d'une ligne y represente bien cette position; le troisieme groupe trace une horizontale dans un rectangle et le quatrieme juge si la ligne illustree y est bien horizontale. Quatre autres groupes executent respectivement les memes taches dans la version classique papier-crayon. Le temps accorde a la reflexion avant de commencer le trace, le temps de tracage comme tel et le temps de verification du trace complete sont calcules. Chez les groupes qui evaluent l'orientation d'une ligne sur support informatique, le temps requis pour y parvenir est note. Enfin, un questionnaire estime si les participants connaissent ou non le principe physique d'invariance de l'orientation de la surface d'un liquide. Les resultats revelent que cette connaissance est plus frequente chez les garcons dans l'ensemble des groupes. Dans le cas ou les sujets ont a tracer une ligne, les filles reussissent moins d'essais que les garcons s'il faut, sur support informatique, tracer la surface de l'eau dans un contenant incline ou a l'horizontale. Il en va de meme s'il faut, sur support papier, tracer une horizontale dans un contenant incline. Le trace de la surface de l'eau est plus exact chez les sujets connaissant le principe d'invariance et l

  9. Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

    Science.gov (United States)

    Masuck, Ines; Hutzler, Christoph; Luch, Andreas

    2010-04-30

    In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air. 2010 Elsevier B.V. All rights reserved.

  10. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Supported liquid membrane stability in chiral resolution by chemically and physically modified membranes

    Energy Technology Data Exchange (ETDEWEB)

    Molinari, R.; Argurio, P. [Arcavata di Rende Univ. of Calabria, Arcavata di Rende, CS (Italy). Dept. of Chemical and Materials Engineering

    2001-04-01

    In the present work some stability studies on Supported Liquid Membranes (SLMs) to be used for chiral separations were realized. In particular, primary aim was to determine how a modification of the support surface influences the SLM stability. First, the procedure for support modification was optimised, making a screening of various compounds (sulphuric acid, nitric acid, chromic acid, sodium dodecyl sulphate (SDS), glycerol, oleic alcohol, propylene glycol (PPG), bovine serum albumin (BSA)) and testing their performance by means of contact angle measurements. Next, a second screening was realized by permeation tests in a stirred cell. Finally, to compare the stability of modified with unmodified support in a process of interest for chemical and/or biochemical industries, some permeation tests for resolution of DNB-DL-Leucine were realized in a re-circulation system. Results showed a better surface hydrophilization of chemically modified support and better stability of the sulphonated support. However, in operating conditions a little high stability of the unmodified support was obtained. [Italian] Nel presente lavoro sono stati realizzati degli studi di stabilita' di Membrane Liquide Supportate (SLMs) da impiegare in separazioni chirali. In particolare, obiettivo principale e' stato quello di determinare l'influenza che una modifica della superficie del supporto ha sulla stabilita' della SLM. Cosi', in un primo momento, e' stata ottimizzata le procedura di modifica del supporto, facendo una selezione tra vari composti (acido solforico, acido nitrico, acido cromico, sodio dodecil solfato (SDS), glicerolo, alcool oleico, glicole propilenico (PPG), siero di albumina bovina (BSA)) basata su misure dell'angolo di contatto. Successivamente, e' stata realizzata una seconda selezione mediante prove di permeazione in una cella agitata. Infine, con lo scopo di confrontare la stabilita' della SLM con supporto modificato rispetto

  12. Metabolic profiling of potential lung cancer biomarkers using bronchoalveolar lavage fluid and the integrated direct infusion/ gas chromatography mass spectrometry platform.

    Science.gov (United States)

    Callejón-Leblic, Belén; García-Barrera, Tamara; Grávalos-Guzmán, Jesús; Pereira-Vega, Antonio; Gómez-Ariza, José Luis

    2016-08-11

    Lung cancer is one of the ten most common causes of death worldwide, so that the search for early diagnosis biomarkers is a very challenging task. Bronchoalveolar lavage fluid (BALF) provides information on cellular and biochemical epithelial surface of the lower respiratory tract constituents and no previous metabolomic studies have been performed with BALF samples from patients with lung cancer. Therefore, this fluid has been explored looking for new contributions in lung cancer metabolism. In this way, two complementary metabolomics techniques based on direct infusion high resolution mass spectrometry (DI-ESI-QTOF-MS) and gas chromatography mass spectrometry (GC-MS) have been applied to compare statistically differences between lung cancer (LC) and control (C) BALF samples, using partial least square discriminant analysis (PLS-DA) in order to find and identify potential biomarkers of the disease. A total of 42 altered metabolites were found in BALF from LC. The metabolic pathway analysis showed that glutamate and glutamine metabolism pathway was mainly altered by this disease. In addition, we assessed the biomarker specificity and sensitivity according to the area under the receiver operator characteristic (ROC) curves, indicating that glycerol and phosphoric acid were potential sensitive and specific biomarkers for lung cancer diagnosis and prognosis. The search for early diagnosis of lung cancer is a very challenging task because of the high mortality associated to this disease and its critical linkage to the initiation of treatment. Bronchoalveolar lavage fluid provides information on cellular and biochemical epithelial surface of the lower respiratory tract constituents and no previous metabolomic studies have been performed with BALF samples from patients with lung cancer. Since BALF is in close interaction with lung tissue it is a more representative sample of lung status than other peripheral biofluids as blood or urine studied in previous works

  13. The identification of synthetic organic pigments in modern paints and modern paintings using pyrolysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Russell, Joanna; Singer, Brian W; Perry, Justin J; Bacon, Anne

    2011-05-01

    A collection of more than 70 synthetic organic pigments were analysed using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We report on the analysis of diketo-pyrrolo-pyrrole, isoindolinone and perylene pigments which are classes not previously reported as being analysed by this technique. We also report on a number of azo pigments (2-naphthol, naphthol AS, arylide, diarylide, benzimidazolone and disazo condensation pigments) and phthalocyanine pigments, the Py-GC-MS analysis of which has not been previously reported. The members of each class were found to fragment in a consistent way and the pyrolysis products are reported. The technique was successfully applied to the analysis of paints used by the artist Francis Bacon (1909-1992), to simultaneously identify synthetic organic pigments and synthetic binding media in two samples of paint taken from Bacon's studio and micro-samples taken from three of his paintings and one painting attributed to him.

  14. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    Science.gov (United States)

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. The leaf volatile constituents of Isatis tinctoria by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry.

    Science.gov (United States)

    Condurso, Cettina; Verzera, Antonella; Romeo, Vincenza; Ziino, Marisa; Trozzi, Alessandra; Ragusa, Salvatore

    2006-08-01

    The leaf volatile constituents of Isatis tinctoria L. (Brassicaceae) have been studied by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry (SPME/GC-MS). Seventy components were fully characterized by mass spectra, linear retention indices, and injection of standards; the average composition (ppm) as single components and classes of substances is reported. Aliphatic hydrocarbons, acids, alcohols, aldehydes and esters, aromatic aldehydes, esters and ethers, furans, isothiocyanates and thiocyanates, sulfurated compounds, nitriles, terpenes and sesquiterpenes were identified. Leaf volatiles in Isatis tinctoria L. were characterized by a high amount of isothiocyanates which accounted for about 40 % of the total volatile fraction. Isothiocyanates are important and characteristic flavour compounds in Brassica vegetables and the cancer chemo-protective attributes are recently responsible for their growing interest.

  16. Exposure Assessment of Acetamide in Milk, Beef, and Coffee Using Xanthydrol Derivatization and Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Vismeh, Ramin; Haddad, Diane; Moore, Janette; Nielson, Chandra; Bals, Bryan; Campbell, Tim; Julian, Allen; Teymouri, Farzaneh; Jones, A Daniel; Bringi, Venkataraman

    2018-01-10

    Acetamide has been classified as a possible human carcinogen, but uncertainties exist about its levels in foods. This report presents evidence that thermal decomposition of N-acetylated sugars and amino acids in heated gas chromatograph injectors contributes to artifactual acetamide in milk and beef. An alternative gas chromatography/mass spectrometry protocol based on derivatization of acetamide with 9-xanthydrol was optimized and shown to be free of artifactual acetamide formation. The protocol was validated using a surrogate analyte approach based on d 3 -acetamide and applied to analyze 23 pasteurized whole milk, 44 raw sirloin beef, and raw milk samples from 14 different cows, and yielded levels about 10-fold lower than those obtained by direct injection without derivatization. The xanthydrol derivatization procedure detected acetamide in every food sample tested at 390 ± 60 ppb in milk, 400 ± 80 ppb in beef, and 39 000 ± 9000 ppb in roasted coffee beans.

  17. Analysis of Volatile Components of Varietal English Wines Using Stir Bar Sorptive Extraction/Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Darren J. Caven-Quantrill

    2017-12-01

    Full Text Available Aroma is an important property of wine and it can be influenced significantly by enological practices. The aim of this work was, by use of stir bar sorptive extraction/gas chromatography-mass spectrometry (SBSE/GC-MS, to compare semi-quantitative concentrations of the volatile constituents of stainless steel tank-fermented/matured Huxelrebe, Ortega, Schönburger and Siegerrebe varietal wines from a commercial English vineyard, with corresponding wines produced by oak cask (‘barrel’ fermentation/maturation. Aroma profiles of tank and barrel wines were different, with more volatiles detected and net concentrations being higher in barrel wines. Long chain ethyl carboxylate esters were generally more abundant in barrel wines, whereas acetate esters were generally more prominent in tank wines. By conducting a short (~7 month maturation period in secondhand (third or fourth fill casks, it was possible to make wines with more complex aromas, but without obvious oak aroma.

  18. Selective 3,4-Dihydroxyphenylalanine Analysis in Human Urine as Ethoxycarbonyltert- butyldimethylsilyl Derivatives by Gas Chromatography-Mass Spectrometry

    International Nuclear Information System (INIS)

    Paik, Man Jeong; Nguyen, Duc Toan; Cho, In Seon; Kim, Kyoung Rae; Cho, Ki Hong; Choi, Sang Dun; Lee, Gwang; Yoon, Jae Hwan; Shim, Woo Young

    2011-01-01

    A new analytical method for measurement of 3,4-dihydroxyphenylalanine (DOPA) in human urine was developed. DOPA from an aqueous solution was converted into an ethoxycarbonyl (EOC) derivative. A tertbutyldimethylsilyl (TBDMS) reaction under anhydrous conditions was then attempted for analysis by gas chromatography-mass spectrometry in selected ion monitoring mode. A new mass spectral data on DOPA as a tri-EOC/mono-TBDMS derivative was built. This method showed good linearity (r ≥ 0.999), precision (% relative standard deviation = 3.1-9.2), and accuracy (% relative error = .7.2-8.8), with a detection limit of 0.05 ng/mL. This selective and accurate method of DOPA analysis will be useful for biochemical monitoring of various neurological disorders including Parkinson's disease in biological fluids

  19. Determination of some volatile compounds in alcoholic beverage by headspace solid-phase microextraction gas chromatography - mass spectrometry

    Science.gov (United States)

    Schmutzer, G.; Avram, V.; Feher, I.; David, L.; Moldovan, Z.

    2012-02-01

    The volatile composition of alcoholic beverage was studied by headspace solid-phase microextraction (HSSPME) method and gas chromatography - mass spectrometry (GC-MS). Some volatile compounds, such as alcohols, esters, terpenes and other are mainly responsible for the flavor of fortified wines and their amounts specify the quality of the alcoholic beverages. From this perspective it is interesting to develop a rapid, selective and sensitive analytical method suitable for simultaneous quantification of the main molecules being responsible for the organoleptic characteristic of alcoholic beverages. Vermouth fortified drink was analyzed in order to characterize the volatile profile. Using the HS-SPME/GC-MS a number of twenty-six volatile compounds from a commercial market alcoholic beverage were identified. The most abundant compounds were m-thymol, o-thymol and eugenol, alongside of the ethyl ester compounds.

  20. Droplet deposition measurement with high-speed camera and novel high-speed liquid film sensor with high spatial resolution

    International Nuclear Information System (INIS)

    Damsohn, M.; Prasser, H.-M.

    2011-01-01

    Highlights: → Development of a sensor for time- and space-resolved droplet deposition in annular flow. → Experimental measurement of droplet deposition in horizontal annular flow to compare readings of the sensor with images of a high-speed camera when droplets are depositing unto the liquid film. → Self-adaptive signal filter based on autoregression to separate droplet impacts in the sensor signal from waves of liquid films. - Abstract: A sensor based on the electrical conductance method is presented for the measurement of dynamic liquid films in two-phase flow. The so called liquid film sensor consists of a matrix with 64 x 16 measuring points, a spatial resolution of 3.12 mm and a time resolution of 10 kHz. Experiments in a horizontal co-current air-water film flow were conducted to test the capability of the sensor to detect droplet deposition from the gas core onto the liquid film. The experimental setup is equipped with the liquid film sensor and a high speed camera (HSC) recording the droplet deposition with a sampling rate of 10 kHz simultaneously. In some experiments the recognition of droplet deposition on the sensor is enhanced by marking the droplets with higher electrical conductivity. The comparison between the HSC and the sensor shows, that the sensor captures the droplet deposition above a certain droplet diameter. The impacts of droplet deposition can be filtered from the wavy structures respectively conductivity changes of the liquid film using a filter algorithm based on autoregression. The results will be used to locally measure droplet deposition e.g. in the proximity of spacers in a subchannel geometry.

  1. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  2. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Souza, Daniele Z.; Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C.; Pechansky, Flavio; Duarte, Paulina C.A.V.; De Boni, Raquel; Froehlich, Pedro E.; Limberger, Renata P.

    2011-01-01

    Graphical abstract: Highlights: → Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. → Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. → Linear range 2(4)-256 ng mL -1 , detection limits 0.5-2 ng mL -1 . → Accuracy 98-112%, precision TM device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL -1 (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL -1 . The detection limits were 0.5 ng mL -1 (MET), 1 ng mL -1 (MPH) and 2 ng mL -1 (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal TM device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  3. Rapid measurement of 13C-enrichment of acetic, propionic and butyric acids in plasma with solid phase microextraction coupled to gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Moreau, N.M.; Delepee, R.; Maume, D.; Le Bizec, B.; Nguyen, P.G.; Champ, M.M.; Martin, L.J.; Dumon, H.J.

    2004-01-01

    An analytical procedure based on solid phase microextraction (SPME) has been developed to quantify [1- 13 C]-labelled short-chain fatty acids (SCFAs)--mainly acetic, propionic and butyric acids--in a small volume (120 μl) of deproteinised plasma (corresponding to 200 μl of raw plasma) by gas chromatography-mass spectrometry (GC-MS) analysis. Simultaneous SCFA extraction was optimal after 5 min using a 75 μm Carboxen/polydimethylsiloxane-coated fiber. The base peak of the three analytes has been characterised by middle-resolution mass spectrometry (R>6000). All these data allowed the specificity reinforcement of the measure. The validation of the method also considered the linearity and the repeatability of the [ 13 C]SCFA measurements by SPME-GC-MS. Results were linear in a range from 5 to 100 mol% of [ 13 C]SCFA enrichment and the method provided a good intra-day (R.S.D. 13 C]butyric acid) by cecal infusion before blood sampling in portal vein. Results of [1- 13 C]butyric acid enrichment showed an excellent correlation (r 2 =0.9832; n=30) with data obtained on the same samples using a previously published procedure based on diethyl extraction and derivatisation before GC-MS analyses. SPME coupled to GC-MS appears to be a powerful analytical tool for the direct isotopic measurements of low deproteinised plasma volume avoiding consequently preliminary treatment such as extraction or derivatisation. The presented method could be of great interest for real time [ 13 C]SCFA plasma determination of in metabolic in vivo studies in small animal models

  4. A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry.

    Science.gov (United States)

    Jumaah, Firas; Plaza, Merichel; Abrahamsson, Victor; Turner, Charlotta; Sandahl, Margareta

    2016-08-01

    In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for α-carotene and astaxa