WorldWideScience

Sample records for resolution ct evaluation

  1. Application of Super-Resolution Convolutional Neural Network for Enhancing Image Resolution in Chest CT.

    Science.gov (United States)

    Umehara, Kensuke; Ota, Junko; Ishida, Takayuki

    2017-10-18

    In this study, the super-resolution convolutional neural network (SRCNN) scheme, which is the emerging deep-learning-based super-resolution method for enhancing image resolution in chest CT images, was applied and evaluated using the post-processing approach. For evaluation, 89 chest CT cases were sampled from The Cancer Imaging Archive. The 89 CT cases were divided randomly into 45 training cases and 44 external test cases. The SRCNN was trained using the training dataset. With the trained SRCNN, a high-resolution image was reconstructed from a low-resolution image, which was down-sampled from an original test image. For quantitative evaluation, two image quality metrics were measured and compared to those of the conventional linear interpolation methods. The image restoration quality of the SRCNN scheme was significantly higher than that of the linear interpolation methods (p < 0.001 or p < 0.05). The high-resolution image reconstructed by the SRCNN scheme was highly restored and comparable to the original reference image, in particular, for a ×2 magnification. These results indicate that the SRCNN scheme significantly outperforms the linear interpolation methods for enhancing image resolution in chest CT images. The results also suggest that SRCNN may become a potential solution for generating high-resolution CT images from standard CT images.

  2. Evaluation of experimental cartilage lesions with ultrahigh-resolution multi-slice-CT in comparison to histology

    International Nuclear Information System (INIS)

    Stork, A.; Kemper, J.; Begemann, P. G. C.; Habermann, C.R.; Adam, G.; Priemel, M.; Kummer, T.; Amling, M.

    2004-01-01

    Purpose: histologic validation of ultrahigh-resolution multislice (MS)-CT for the evaluation of focal, experimental cartilage lesions with special regard to the subchondral bone. Testing of micro-CTCT) as alternative reference standard. Methods: 32 experimental cartilage lesions in bovine patellae were imaged surrounded by air (MS-CT-air) and immersed in a contrast material solution (MS-CT-CM) with MS-CT (collimation 2 x 0,5 mm). After the μCT (8 μm-voxelsite) examination in three specimen and histologic work-up of 29 specimen two radiologist graded the defects on MS-CT images in consensus (subchondral bone involvement yes or no) and results were compared to the results of histomorphometry and μCT. Results: the MS-CT-air and -CM had an accuracy of 94% (30/32) and 88% (28/32), respectively. MS-CT-air led to one false-positive (remaining cartilage: = 0,1 mm) and false-negative result, each. MS-CT-CM showed false-positive results if the remaining cartilage was [de

  3. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  4. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  5. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  6. High resolution CT of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Harumi (Kyoto Univ. (Japan). Faculty of Medicine)

    1991-02-01

    The emergence of computed tomography (CT) in the early 1970s has greatly contributed to diagnostic radiology. The brain was the first organ examined with CT, followed by the abdomen. For the chest, CT has also come into use shortly after the introduction in the examination of the thoracic cavity and mediastinum. CT techniques were, however, of limited significance in the evaluation of pulmonary diseases, especially diffuse pulmonary diseases. High-resolution CT (HRCT) has been introduced in clinical investigations of the lung field. This article is designed to present chest radiographic and conventional tomographic interpretations and to introduce findings of HRCT corresponding to the same shadows, with a summation of the significance of HRCT and issues of diagnostic imaging. Materials outlined are tuberculosis, pneumoconiosis, bronchopneumonia, mycoplasma pneumonia, lymphangitic carcinomatosis, sarcoidosis, diffuse panbronchiolitis, interstitial pneumonia, and pulmonary emphysema. Finally, an overview of basic investigations evolved from HRCT is given. (N.K.) 140 refs.

  7. Evaluation of high-resolution CT after tympanoplasty

    International Nuclear Information System (INIS)

    Torizuka, T.; Hayakawa, K.; Sato, Y.; Tanaka, F.; Okuno, Y.

    1991-01-01

    This paper reports on the condition of the middle ear cavity following tympanoplasty which is always of great interest to radiologists and otosurgeons. This study consisted of 21 patients who had various types of tympanoplasty (types I-IV) for chronic otitis media and cholesteatoma by using high-resolution CT (HRCT). HRCT following tympanoplasty was a valuable method for assessing the middle ear aeration and the state of ossicular reconstruction, including stapes prosthesis, although in some cases of soft-tissue mass in the middle ear it was necessary to correlate with clinical findings in order to differentiate between granulation and recurrence

  8. Clinical evaluation of high-resolution CT, 1. CT diagnosis of liver tumors and its limit

    Energy Technology Data Exchange (ETDEWEB)

    Araki, T [Tokyo Univ. (Japan). Faculty of Medicine

    1980-03-01

    To estimate diagnostic accuracy of CT in liver tumors, CT diagnosis in 120 patients with primary hepatocellular carcinoma was discussed. As a result, primary hepatocellular carcinoma less than 2 cm in diameter could not be visualized by CT. Even tumors between 4 and 8 cm in diameter showed false negative caused by isodense tumors on images of 4 patients. To improve the detectability of liver tumors by CT, the higher resolution of low contrast regions on images are required. As a method to improve qualitative diagnosis of liver tumors, rapid intravenous injection of contrast medium was performed on 42 patients with liver tumors, As a result, images reflecting vascularity of tumors were obtained, and the differential diagnosis was possible to some extent by observing the movement of the contrast. Especially, cavernous hemangioma could be distinguished from hepatocellular carcinoma, because cavernous hemangioma showed specific images and could be diagnosed accurately.

  9. Prospective evaluation of solitary thyroid nodule on 18F-FDG PET/CT and high-resolution ultrasonography

    International Nuclear Information System (INIS)

    D'Souza, M.M.; Marwaha, R.K.; Sharma, R.

    2010-01-01

    The utility of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the assessment of thyroid nodules is unclear as there are several conflicting reports on the usefulness of standardized uptake value (SUV) as an indicator to distinguish benign from malignant thyroid lesions. This study incorporated an additional parameter, namely dual time point imaging, to determine the diagnostic accuracy of PET/CT imaging. The performance of 18F-FDG PET/CT was compared to that of high-resolution ultrasound which is routinely used for the evaluation of thyroid nodules. Two hundred patients with incidentally detected solitary thyroid nodules were included in the study. Each patient underwent ultrasound and PET/CT evaluation within 7 days of each other, reported by an experienced radiologist and nuclear medicine specialist, respectively, in a blinded manner. The PET/CT criteria employed were maximum SUV (SUV max ) at 60 min and change in SUV max at delayed (120 min) imaging. Final diagnosis was based on pathological evaluation and follow-up. Of the 200 patients, 26 had malignant and 174 had benign nodules. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of ultrasound were 80.8, 81.6, 39.6, 96.6 and 81.5%, respectively. Using SUV max at 60 min as the diagnostic criterion, the above indices were 80.8, 84.5, 43.8, 96.7 and 84%, respectively, for PET/CT. The SUV max of malignant thyroid lesions was significantly higher than benign lesions (16.2±10.6 vs. 4.5±3.1, respectively; p=0.0001). Incorporation of percentage change in SUV max at delayed imaging as the diagnostic criterion yielded a slightly improved sensitivity, specificity, PPV, NPV and accuracy of 84.6, 85.6, 46.8, 97.4 and 85.5%, respectively. There was a significant difference in percentage change in SUV max between malignant and benign thyroid lesions (14.9±11.4 vs. -1.6±13.7, respectively; p=0.0001). However, there was no statistically

  10. High-resolution CT findings in Streptococcus milleri pulmonary infection

    International Nuclear Information System (INIS)

    Okada, F.; Ono, A.; Ando, Y.; Nakayama, T.; Ishii, H.; Hiramatsu, K.; Sato, H.; Kira, A.; Otabe, M.; Mori, H.

    2013-01-01

    Aim: To assess pulmonary high-resolution computed tomography (CT) findings in patients with acute Streptococcus milleri pulmonary infection. Materials and methods: Sixty consecutive patients with acute S. milleri pneumonia who had undergone high-resolution CT chest examinations between January 2004 and March 2010 were retrospectively identified. Twenty-seven patients with concurrent infections were excluded. The final study group comprised 33 patients (25 men, 8 women; aged 20–88 years, mean 63.1 years) with S. milleri infection. The patients' clinical findings were assessed. Parenchymal abnormalities, enlarged lymph nodes, and pleural effusion were evaluated on high-resolution CT. Results: Underlying conditions included malignancy (n = 15), a smoking habit (n = 11), and diabetes mellitus (n = 8). CT images of all patients showed abnormal findings, including ground-glass opacity (n = 24), bronchial wall thickening (n = 23), consolidation (n = 17), and cavities (n = 7). Pleural effusion was found in 18 patients, and complex pleural effusions were found in seven patients. Conclusion: Pulmonary infection caused by S. milleri was observed mostly in male patients with underlying conditions such as malignancy or a smoking habit. The CT findings in patients with S. milleri consisted mainly of ground-glass opacity, bronchial wall thickening, pleural effusions, and cavities

  11. High resolution CT of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Barneveld Binkhuysen, F H [Eemland Hospital (Netherlands), Dept. of Radiology

    1996-12-31

    Compared to conventional CT high resolution CT (HRCT) shows several extra anatomical structures which might effect both diagnosis and therapy. The extra anatomical structures were discussed briefly in this article. (18 refs.).

  12. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Honda, Eiichi; Tetsumura, Akemi; Kurabayashi, Tohru

    2011-01-01

    Purpose: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases. Materials and methods: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom. Results: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64x) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64. Conclusions: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases.

  13. High-resolution CT of otosclerosis

    International Nuclear Information System (INIS)

    Dewen, Yang; Kodama, Takao; Tono, Tetsuya; Ochiai, Reiji; Kiyomizu, Kensuke; Suzuki, Yukiko; Yano, Takanori; Watanabe, Katsushi

    1997-01-01

    High-resolution CT (HRCT) scans of thirty-two patients (60 ears) with the clinical diagnosis of fenestral otosclerosis were evaluated retrospectively. HRCT was performed with 1-mm-thick targeted sections and 1-mm (36 ears) or 0.5-mm (10 ears) intervals in the semiaxial projection. Seven patients (14 ears) underwent helical scanning with a 1-mm slice thickness and 1-mm/sec table speed. Forty-five ears (75%) were found to have one or more otospongiotic or otosclerotic foci on HRCT. In most instances (30 ears), the otospongiotic foci were found in the region of the fissula ante fenestram. No significant correlations between CT findings and air conduction threshold were observed. We found a significant relationship between lesions of the labyrinthine capsule and sensorineural hearing loss. We conclude that HRCT is a valuable modality for diagnosing otosclerosis, especially when otospongiotic focus is detected. (author)

  14. 1024 matrix image reconstruction: usefulness in high resolution chest CT

    International Nuclear Information System (INIS)

    Jeong, Sun Young; Chung, Myung Jin; Chong, Se Min; Sung, Yon Mi; Lee, Kyung Soo

    2006-01-01

    We tried to evaluate whether high resolution chest CT with a 1,024 matrix has a significant advantage in image quality compared to a 512 matrix. Each set of 512 and 1024 matrix high resolution chest CT scans with both 0.625 mm and 1.25 mm slice thickness were obtained from 26 patients. Seventy locations that contained twenty-four low density lesions without sharp boundary such as emphysema, and forty-six sharp linear densities such as linear fibrosis were selected; these were randomly displayed on a five mega pixel LCD monitor. All the images were masked for information concerning the matrix size and slice thickness. Two chest radiologists scored the image quality of each ar rowed lesion as follows: (1) undistinguishable, (2) poorly distinguishable, (3) fairly distinguishable, (4) well visible and (5) excellently visible. The scores were compared from the aspects of matrix size, slice thickness and the different observers by using ANOVA tests. The average and standard deviation of image quality were 3.09 (± .92) for the 0.625 mm x 512 matrix, 3.16 (± .84) for the 0.625 mm x 1024 matrix, 2.49 (± 1.02) for the 1.25 mm x 512 matrix, and 2.35 (± 1.02) for the 1.25 mm x 1024 matrix, respectively. The image quality on both matrices of the high resolution chest CT scans with a 0.625 mm slice thickness was significantly better than that on the 1.25 mm slice thickness (ρ < 0.001). However, the image quality on the 1024 matrix high resolution chest CT scans was not significantly different from that on the 512 matrix high resolution chest CT scans (ρ = 0.678). The interobserver variation between the two observers was not significant (ρ = 0.691). We think that 1024 matrix image reconstruction for high resolution chest CT may not be clinical useful

  15. [Adult transient intestinal intussusception: can abdominal CT guide resolution?].

    Science.gov (United States)

    Stabile Ianora, Amato Antonio; Telegrafo, Michele; Lorusso, Valentina; Rella, Leonarda; Niccoli Asabella, Artor; La Porta, Michele; Moschetta, Marco

    2013-01-01

    The purpose of this study was to evaluate the adult transient intestinal intussusceptions on CT before and after the administration of gastrointestinal contrast material. We evaluated two different gastrointestinal contrast materials: hyperdense and hypodense. In all cases the gastrointestinal contrast agent solved the invaginations. In the group of patients treated with hypodense contrast medium relapses occurred in the short and long term; no recurrence was observed in the other group. CT is useful in the recognition of intestinal intussusception. The gastrointestinal contrast agent could define the real transience of intussusceptions and hyperdense contrast agent could be more effective in short and long term resolution.

  16. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration.

    Science.gov (United States)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander; Lefolii, Tore Tranberg; Jørgensen, Niklas Rye; Feidenhans'l, Robert; Pinholt, Else Marie

    2015-06-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase to 50% as the radial distance from the implant surface increased, and levelled out to approximately 80% at a distance of 400 μm. This method has been successful in depicting the bone and cavities in three dimensions thereby enabling us to give a more precise answer to the fraction of the bone-to-implant contact compared to previous methods. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast...... establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone....... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT...

  18. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  19. Resolution enhancement of lung 4D-CT via group-sparsity

    International Nuclear Information System (INIS)

    Bhavsar, Arnav; Wu, Guorong; Shen, Dinggang; Lian, Jun

    2013-01-01

    Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as

  20. High-resolution CT of temporal bone trauma: review of 38 cases

    International Nuclear Information System (INIS)

    Hiroual, M.R.; Zougarhi, A.; Cherif Idrissi El Ganouni, N.; Essadki, O.; Ousehal, A.; Tijani Adil, O.; Maliki, O.; Aderdour, L.; Raji, A.

    2010-01-01

    Purpose Temporal bone trauma is frequent but difficult to assess due to the diversity of clinical presentations and complex anatomy. We have sought to assess the different types of fractures and complications on high-resolution CT. Materials and methods Descriptive retrospective study over a 24 month period performed in the ENT radiology section of the Mohammed 6 university medical center in Marrakech. A total of 38 cases of temporal bone trauma were reviewed. All patients underwent ENT evaluation and high-resolution CT of the temporal bone using 1 mm axial and coronal sections. Results Mean patient age was 33 years (range: 14-55 years) with male predominance (sex ratio: 36/2). Clinical symptoms were mainly otorrhagia and conductive hearing loss. Oblique extra-labyrinthine fractures were most frequent. Two cases of pneumo-labyrinth were noted. Management was conservative in most cases with deafness in 3 cases. Conclusion High-resolution CT of the temporal bone provides accurate depiction of lesions explaining the clinical symptoms and helps guide management. MRI is complimentary to further assess the labyrinth and VII-VIII nerve complex. (author)

  1. Comparison of the image quality between volumetric and conventional high-resolution CT with 64-slice row CT

    International Nuclear Information System (INIS)

    Gao Yanli; Zhang Lei; Zhao Xia; Ma Min; Zhai Renyou

    2008-01-01

    Objective: To compare the image quality between volumetric high-resolution CT (VHRCT) and conventional high-resolution CT (CHRCT), and investigate the feasibility of VHRCT. Methods: Catphan 412 phantom was scanned with protocols of CHRCT and VHRCT on a set of GE Lightspeed VCT. The spatial-resolution (LP/cm), noise (standard deviation in an ROI) and radiation close (CTDI) were recorded for each CT scan. Difference of noise between CHRCT and VHRCT were evaluated by paired t test. In clinical study, 32 patients were scanned with VHRCT and CHRCT protocols. The image quality of CHRCT and VHRCT was rated and compared. The quality difference between CHRCT and VHRCT was assessed by Wilcoxon paired signed rank sum test. Results: In phantom study, the in-plane spatial-resolution of both VHRCT and CHRCT was 11 LP/cm for axial images and 12 LP/cm for coronal reformatted images. The noise of VHRCT and CHRCT was (69.18±2.77)HU and (54.62±2.12) HU respectively (t=-15.929, P 0.05). The quality assessment scores of VHRCT coronal reformatted images and CHRCT coronal reformatted images were 3.05 and 1.88 respectively with significant difference (Z= -5.088, P<0.01). Conclusion: The image quality of VHRCT cross-sectional image is similar to that of CHRCT. Multiplanar images with high resolution of VHRCT are recommended. The radiation dose of VHRCT remains to be optimized. (authors)

  2. Performance evaluation of 8 CT scanners for clinical use in Italy

    International Nuclear Information System (INIS)

    Pinto, I.; De Denaro, M.; Giribona, P.; Gicericin, C.; Bravar, D.

    1988-01-01

    In the past few years the use of CT scanners has widely spread in Italian care institutions. This methodology has thus become an important creates the need for an accurate study of the various aspects of the phenomenon, e.g. technological, diagnostic and economic. In order to evaluate the quality of the CT scanners used in our country, the majors suppliers of the Italian market were asked to provide us with a unit from their production. Six out of 7 companies complied with our request. A standard protocol was used to evaluate the performance of 8 CT scanners, currently used in Italy. The following parameters were evaluated: spatial resolution, contrast resolution, noise, slice thickness, uniformity, linearity and radiation dose. Five currently-used operating modalities were employed. The results allow an overall assessment of the performance of the 8 CT scanners

  3. Dual resolution cone beam breast CT: A feasibility study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shen Youtao; Lai, Chao-Jen; Han Tao; Zhong Yuncheng; Ge Shuaiping; Liu Xinming; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.; Shaw, Chris C.

    2009-01-01

    Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 μm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

  4. Usefulness evaluation of low-dose for emphysema: Compared with high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jeong [Dept. of Radiological Technology, Daejeon Health Institute of Technology, Daejeon (Korea, Republic of)

    2016-09-15

    The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

  5. Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: in vivo small animal study

    Science.gov (United States)

    Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui

    2011-03-01

    Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.

  6. Evaluation of image quality with different field of view in CT scan of the body in children

    International Nuclear Information System (INIS)

    Gao Dechun; Wu Tai; Mao Dingli; Weng Zhigao

    2005-01-01

    Objective: To evaluate the relationship between field of view (FOV) and quality of CT images. Methods: Scanning of the phantoms of spatial resolution and density resolution was performed with FOVs of 25 cm x 25 cm, 35 cm x 35 cm, and 42 cm x 42 cm, respectively, and the spatial resolution and density resolution of CT images with different FOVs were measured. 20 patients underwent CT scanning using 25 cm x 25 cm and 35 cm x 35 cm FOVs, respectively. The images were evaluated by 3 qualified CT doctors by using a double-blind reading. Results: As FOVs changed, the spatial resolution and density resolution were different. The best spatial resolution and density resolution were obtained on 25 cm x 25 cm FOV images. The best spatial resolution could distinguish four 0.6 mm-diameter eyelets, and the best density resolution could distinguish five 2.5 mm-diameter eyelets. The CT images with 25 cm x 25 cm FOV were obviously better than those with 35 cm x 35 cm FOV (P<0.05). Conclusion: On the range of conventional FOV of CT, the spatial resolution and density resolution of CT images are the best when 25 cm x 25 cm FOV is used. (authors)

  7. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact.

    Science.gov (United States)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander; Lauridsen, Torsten; Hauge, Ellen-Margrethe; Jørgensen, Henrik L; Jørgensen, Niklas Rye; Feidenhansl, Robert; Pinholt, Else Marie

    2017-09-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone. The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT method, one histologic bone section is comparable to the 3D evaluation. Further, the two methods complement each other with knowledge on BIC in 2D and 3D. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. High resolution CT of temporal bone trauma

    International Nuclear Information System (INIS)

    Youn, Eun Kyung

    1986-01-01

    Radiographic studies of the temporal bone following head trauma are indicated when there is cerebrospinal fluid otorrhea or rhinorrhoea, hearing loss, or facial nerve paralysis. Plain radiography displays only 17-30% of temporal bone fractures and pluridirectional tomography is both difficult to perform, particularly in the acutely ill patient, and less satisfactory for the demonstration of fine fractures. Consequently, high resolution CT is the imaging method of choice for the investigation of suspected temporal bone trauma and allows special resolution of fine bony detail comparable to that attainable by conventional tomography. Eight cases of temporal bone trauma examined at Korea General Hospital April 1985 through May 1986. The results were as follows: Seven patients (87%) suffered longitudinal fractures. In 6 patients who had purely conductive hearing loss, CT revealed various ossicular chain abnormality. In one patient who had neuro sensory hearing loss, CT demonstrated intract ossicular with a fracture nearing lateral wall of the lateral semicircular canal. In one patient who had mixed hearing loss, CT showed complex fracture.

  9. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    Energy Technology Data Exchange (ETDEWEB)

    Du, Louise Y [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Umoh, Joseph [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Nikolov, Hristo N [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Pollmann, Steven I [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Lee, Ting-Yim [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Holdsworth, David W [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada)

    2007-12-07

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 {mu}m, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm{sup -1} and noise of {+-}35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.

  10. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    International Nuclear Information System (INIS)

    Du, Louise Y; Umoh, Joseph; Nikolov, Hristo N; Pollmann, Steven I; Lee, Ting-Yim; Holdsworth, David W

    2007-01-01

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 μm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm -1 and noise of ±35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy

  11. Reduction of ring artefacts in high resolution micro-CT reconstructions

    International Nuclear Information System (INIS)

    Sijbers, Jan; Postnov, Andrei

    2004-01-01

    High resolution micro-CT images are often corrupted by ring artefacts, prohibiting quantitative analysis and hampering post processing. Removing or at least significantly reducing such artefacts is indispensable. However, since micro-CT systems are pushed to the extremes in the quest for the ultimate spatial resolution, ring artefacts can hardly be avoided. Moreover, as opposed to clinical CT systems, conventional correction schemes such as flat-field correction do not lead to satisfactory results. Therefore, in this note a simple but efficient and fast post processing method is proposed that effectively reduces ring artefacts in reconstructed μ-CT images. (note)

  12. Lymphocytic interstitial pneumonia in children with AIDS: high-resolution CT findings

    International Nuclear Information System (INIS)

    Becciolini, V.; Gudinchet, F.; Schnyder, P.; Cheseaux, J.J.

    2001-01-01

    Pulmonary involvement in children with acquired immunodeficiency syndrome (AIDS) represents a wide spectrum of diseases. Among the non-infectious, non-neoplastic affections associated with AIDS, lymphocytic interstitial pneumonia (LIP) is now a well-recognized entity, but its radiological pattern studied with high-resolution computed tomography (HRCT) has rarely been described in children. The aim of this study was to illustrate the HRCT spectrum of pulmonary involvement in children with LIP and to evaluate its usefulness in the early diagnosis of this entity. Twelve children with AIDS, aged 3-9 years (mean age 5 years 7 months), underwent chest radiographs and HRCT. A control group of 7 healthy aged-matched children was also studied in the same conditions. Diagnosis of LIP was based on clinical data and HRCT findings. Eight children of 12 had a reticulonodular pattern on chest radiographs. Two children had normal chest films and two children showed peribronchiolar thickening. High-resolution CT displayed micronodules, 1-3 mm in diameter, with a perilymphatic distribution in all patients. High-resolution CT demonstrated also subpleural nodules in children without reticulonodular opacities on chest radiographs. High-resolution CT is able to define a more specific pattern of abnormalities than conventional chest radiographs in children with LIP, allows an earlier and more confident diagnosis and may be useful for the detection of other pathologies associated with AIDS, such as opportunistic infections or superimposed malignancies. (orig.)

  13. The use of thin-section high-resolution CT in pediatric pulmonary disease

    International Nuclear Information System (INIS)

    Hay, T.C.; Horgan, J.G.; Rumack, C.M.

    1989-01-01

    High-resolution thin-section CT of the chest was used successfully to characterize the extent of pulmonary disease. This paper reports on a study in which ten children with chronic lung disorders (including cystic fibrosis, reactive airway disease, and idiopathic disease) were evaluated to test the accuracy of the posteroanterior and lateral chest CT, with both thick (1 cm) and thin (1-3 mm) sections. Unsuspected bronchiectasis was established n two patients with reactive airway disease, and the extent of bronchiectasis in other patients was best defined on thin-section CT. Technique was crucial for an accurate study, and magnification views of each lung were useful. Thin-section CT of the chest was helpful in defining and localizing the extent of these pulmonary disorders

  14. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  15. High-resolution CT of airway reactivity

    International Nuclear Information System (INIS)

    Herold, C.J.; Brown, R.H.; Hirshman, C.A.; Mitzner, W.; Zerhouni, E.A.

    1990-01-01

    Assessment of airway reactivity has generally been limited to experimental nonimaging models. This authors of this paper used high-resolution CT (HRCT) to evaluate airway reactivity and to calculate airway resistance (Raw) compared with lung resistance (RL). Ten anesthetized and ventilated dogs were investigated with HRCT (10 contiguous 2-mm sections through the lower lung lobes) during control state, following aerosol histamine challenge, and following posthistamine hyperinflation. The HRCT scans were digitized, and areas of 10 airways per dog (diameter, 1-10 mm) were measured with a computer edging process. Changes in airway area and Raw (calculated by 1/[area] 2 ) were measured. RL was assessed separately, following the same protocol. Data were analyzed by use of a paired t-test with significance at p < .05

  16. Ring artifact correction for high-resolution micro CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Prell, Daniel; Kalender, Willi A

    2009-01-01

    In high-resolution micro CT using flat detectors (FD), imperfect or defect detector elements may cause concentric-ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. We here present a dedicated image-based ring artifact correction method for high-resolution micro CT, based on median filtering of the reconstructed image and working on a transformed version of the reconstructed images in polar coordinates. This post-processing method reduced ring artifacts in the reconstructed images and improved image quality for phantom and in in vivo scans. Noise and artifacts were reduced both in transversal and in multi-planar reformations along the longitudinal axis. (note)

  17. Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction

    Science.gov (United States)

    Fang, Shiting; Wang, Huafeng; Liu, Yueliang; Zhang, Minghui; Yang, Wei; Feng, Qianjin; Chen, Wufan; Zhang, Yu

    2017-10-01

    Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related health risk. Therefore, resolution enhancement along the superior-inferior direction is necessary. In this paper, a super-resolution (SR) reconstruction method based on a patch low-rank matrix reconstruction is proposed to improve the resolution of lung 4D-CT images. Specifically, a low-rank matrix related to every patch is constructed by using a patch searching strategy. Thereafter, the singular value shrinkage is employed to recover the high-resolution patch under the constraints of the image degradation model. The output high-resolution patches are finally assembled to output the entire image. This method is extensively evaluated using two public data sets. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 9.7%-33.4% and the edge width by 11.4%-24.3%, relative to linear interpolation, back projection (BP) and Zhang et al’s algorithm. A new algorithm has been developed to improve the resolution of 4D-CT. In all experiments, the proposed method outperforms various interpolation methods, as well as BP and Zhang et al’s method, thus indicating the effectivity and competitiveness of the proposed algorithm.

  18. The demonstration of the auditory ossicles by high resolution CT

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.; Boulay, G.H. du; Phelps, P.D.; Pullicino, P.

    1979-01-01

    The high resolution CT scanning system introduced by EMI in 1978 has added a new dimension to computerised tomography in otology. The apparatus used for this study was an EMI CT 5005 body scanner adapted for head and neck scanning and incorporating a high resolution facility. The latter has proved most advantageous in areas of relatively high differential absorption, so that its application to the demonstration of abnormalities in the petrous temporal bone, and in particular middle ear disease, has been very rewarding. Traumatic ossicular disruptions may now be demonstrated and the high contrast of CT often shows them better than conventional hypocycloidal tomography. The stapes is also better visualised and congenital abnormalities of its superstructure have been recorded. These studies have been achieved with a very acceptable level of radiation to the eye, lens and cornea and the technique is clearly a rival to conventional pluridirectional tomography in the assessment of the petrous temporal bone. With further design improvements high resolution CT could completely replace existing techniques. (orig.) [de

  19. Effects of ray profile modeling on resolution recovery in clinical CT

    International Nuclear Information System (INIS)

    Hofmann, Christian; Knaup, Michael; Kachelrieß, Marc

    2014-01-01

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to

  20. High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianzhong; Cao, Yong; Wu, Tianding; Li, Dongzhe [Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008 (China); Lu, Hongbin, E-mail: hongbinlu@hotmail.com [Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008 (China)

    2014-10-15

    Purpose: Understanding the three-dimensional (3D) morphology of the spinal cord microvasculature has been limited by the lack of an effective high-resolution imaging technique. In this study, synchrotron radiation microcomputed tomography (SRµCT), a novel imaging technique based on absorption imaging, was evaluated with regard to the detection of the 3D morphology of the rat spinal cord microvasculature. Methods: Ten Sprague-Dawley rats were used in this ex vivo study. After contrast agent perfusion, their spinal cords were isolated and scanned using conventional x-rays, conventional micro-CT (CµCT), and SRµCT. Results: Based on contrast agent perfusion, the microvasculature of the rat spinal cord was clearly visualized for the first time ex vivo in 3D by means of SRµCT scanning. Compared to conventional imaging techniques, SRµCT achieved higher resolution 3D vascular imaging, with the smallest vessel that could be distinguished approximately 7.4 μm in diameter. Additionally, a 3D pseudocolored image of the spinal cord microvasculature was generated in a single session of SRµCT imaging, which was conducive to detailed observation of the vessel morphology. Conclusions: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.

  1. Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A.; Kolditz, Daniel; Lueck, Ferdinand [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); CT Imaging GmbH, Erlangen (Germany); Steiding, Christian [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); CT Imaging GmbH, Erlangen (Germany); University Hospital of Erlangen, Institute of Radiology, Erlangen (Germany); Ruth, Veikko; Roessler, Ann-Christin [University of Erlangen-Nuernberg, Institute of Medical Physics (IMP), Erlangen (Germany); Wenkel, Evelyn [University Hospital of Erlangen, Institute of Radiology, Erlangen (Germany)

    2017-03-15

    X-ray computed tomography (CT) has been proposed and evaluated multiple times as a potentially alternative method for breast imaging. All efforts shown so far have been criticized and partly disapproved because of their limited spatial resolution and higher patient dose when compared to mammography. Our concept for a dedicated breast CT (BCT) scanner therefore aimed at novel apparatus and detector design to provide high spatial resolution of about 100 μm and average glandular dose (AGD) levels of 5 mGy or below. Photon-counting technology was considered as a solution to reach these goals. The complete concept was previously evaluated and confirmed by simulations and basic experiments on laboratory setups. We here present measurements of dose, technical image quality parameters and surgical specimen results on such a scanner. For comparison purposes, the specimens were also imaged with digital mammography (DM) and breast tomosynthesis (BT) apparatus. Results show that photon-counting BCT (pcBCT) at 5 mGy AGD offers sufficiently high 3D spatial resolution for reliable detectability of calcifications and soft tissue delineation. (orig.)

  2. Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

    International Nuclear Information System (INIS)

    Zhang Yu; Yap, Pew-Thian; Wu Guorong; Feng Qianjin; Chen Wufan; Lian Jun; Shen Dinggang

    2013-01-01

    Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors’ algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors’ algorithm increases peak signal-to-noise ratio by 3–4 dB and the structural similarity index by 3%–5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It

  3. Evaluation of pneumoconiosis by high-resolution CT

    International Nuclear Information System (INIS)

    Egashira, Kanji

    1991-01-01

    Forty-eight patients with pneumoconiosis (47 males and one female) were evaluated by high-resolution computed tomography (HRCT), which was compared with chest radiography and pulmonary function studies. HRCT was superior to chest radiography in detecting small nodular shadows. There was a good correlation between HRCT and chest radiography in evaluating nodule quantity and size. HRCT was superior to chest radiography in detecting emphysematous changes, and the difference was significant. HRCT and chest radiography were closely correlated in their evaluation of the grade of emphysema. The grade of emphysema on HRCT was negatively correlated with the number of nodules. Subpleural curvilinear shadow (SCLS) on HRCT was correlated with the grade of emphysema, but not with the number of nodules. The comparison with pulmonary function studies showed that the emphysematous change on HRCT alone was correlated with %DLCO, while SCLS was correlated with FEV 1.0 %, RV/TLC and %DLCO. HRCT of the lung is useful for complementing chest radiography and pulmonary function studies in the evaluation of pneumoconiosis. (author)

  4. High resolution extremity CT for biomechanics modeling

    International Nuclear Information System (INIS)

    Ashby, A.E.; Brand, H.; Hollerbach, K.; Logan, C.M.; Martz, H.E.

    1995-01-01

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling

  5. High resolution extremity CT for biomechanics modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, A.E.; Brand, H.; Hollerbach, K.; Logan, C.M.; Martz, H.E.

    1995-09-23

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling.

  6. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  7. High resolution CT in the investigation of bone destruction in the outer ear

    International Nuclear Information System (INIS)

    Koester, O.; Straehler-Pohl, H.J.; Bonn Univ.

    1986-01-01

    Eleven patients with known malignant tumours of the outer ear and three patients with otitis externa maligna were examined by high resolution CT. CT provided accurate information concerning soft tissue infiltration into the parotid or subtemporal tissues, and of the bony destruction in the mastoid, meatus and tympanic cavity. Absolute differentiation between a malignant tumour and otitis cisterna maligna is not possible, not even by high resolution CT. (orig.) [de

  8. Tuberculous otitis media: findings on high-resolution CT

    International Nuclear Information System (INIS)

    Lungenschmid, D.; Buchberger, W.; Schoen, G.; Schoepf, R.; Mihatsch, T.; Birbamer, G.; Wicke, K.

    1993-01-01

    We describe two cases of tuberculous otitis media studied with high-resolution computed tomography (CT). Findings included extensive soft tissue densities with fluid levels in the tympanic cavity, the antrum, the mastoid and petrous air cells. Multifocal bony erosions and reactive bone sclerosis were seen as well. CT proved valuable for planning therapy by accurately displaying the involvement of the various structures of the middle and inner ear. However, the specific nature of the disease could only be presumed. (orig.)

  9. Pneumonia: high-resolution CT findings in 114 patients

    Energy Technology Data Exchange (ETDEWEB)

    Reittner, Pia [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Department of Radiology, Karl Franzens University and University Hospital Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L. [Department of Radiology, Vancouver Hospital and Health Sciences Center, 855 W. 12th Ave., Vancouver, BC (Canada); Johkoh, Takeshi [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan)

    2003-03-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  10. Pneumonia: high-resolution CT findings in 114 patients

    International Nuclear Information System (INIS)

    Reittner, Pia; Ward, Suzanne; Heyneman, Laura; Mueller, Nestor L.; Johkoh, Takeshi

    2003-01-01

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  11. Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: Initial patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Apfaltrer, Paul, E-mail: paul.apfaltrer@medma.uni-heidelberg.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoendube, Harald, E-mail: harald.schoendube@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Allmendinger, Thomas, E-mail: thomas.allmendinger@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Tricarico, Francesco, E-mail: francescotricarico82@gmail.com [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, “A. Gemelli” Hospital, Largo A. Gemelli 8, Rome (Italy); Schindler, Andreas, E-mail: andreas.schindler@campus.lmu.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Vogt, Sebastian, E-mail: sebastian.vogt@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Sunnegårdh, Johan, E-mail: johan.sunnegardh@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); and others

    2013-02-15

    Objective: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. Materials and methods: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175–426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. Results: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m{sup 2}. Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p > 0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p > 0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p < 0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median = 2.5) and TRIM (median = 2.0) reconstructions. Conclusion: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients.

  12. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT.

    Science.gov (United States)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-03-01

    The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used

  13. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

    International Nuclear Information System (INIS)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-01-01

    Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same

  14. Interior tomography in microscopic CT with image reconstruction constrained by full field of view scan at low spatial resolution

    Science.gov (United States)

    Luo, Shouhua; Shen, Tao; Sun, Yi; Li, Jing; Li, Guang; Tang, Xiangyang

    2018-04-01

    In high resolution (microscopic) CT applications, the scan field of view should cover the entire specimen or sample to allow complete data acquisition and image reconstruction. However, truncation may occur in projection data and results in artifacts in reconstructed images. In this study, we propose a low resolution image constrained reconstruction algorithm (LRICR) for interior tomography in microscopic CT at high resolution. In general, the multi-resolution acquisition based methods can be employed to solve the data truncation problem if the project data acquired at low resolution are utilized to fill up the truncated projection data acquired at high resolution. However, most existing methods place quite strict restrictions on the data acquisition geometry, which greatly limits their utility in practice. In the proposed LRICR algorithm, full and partial data acquisition (scan) at low and high resolutions, respectively, are carried out. Using the image reconstructed from sparse projection data acquired at low resolution as the prior, a microscopic image at high resolution is reconstructed from the truncated projection data acquired at high resolution. Two synthesized digital phantoms, a raw bamboo culm and a specimen of mouse femur, were utilized to evaluate and verify performance of the proposed LRICR algorithm. Compared with the conventional TV minimization based algorithm and the multi-resolution scout-reconstruction algorithm, the proposed LRICR algorithm shows significant improvement in reduction of the artifacts caused by data truncation, providing a practical solution for high quality and reliable interior tomography in microscopic CT applications. The proposed LRICR algorithm outperforms the multi-resolution scout-reconstruction method and the TV minimization based reconstruction for interior tomography in microscopic CT.

  15. Comparative study between ultrahigh spatial frequency algorithm and high spatial frequency algorithm in high-resolution CT of the lungs

    International Nuclear Information System (INIS)

    Oh, Yu Whan; Kim, Jung Kyuk; Suh, Won Hyuck

    1994-01-01

    To date, the high spatial frequency algorithm (HSFA) which reduces image smoothing and increases spatial resolution has been used for the evaluation of parenchymal lung diseases in thin-section high-resolution CT. In this study, we compared the ultrahigh spatial frequency algorithm (UHSFA) with the high spatial frequency algorithm in the assessment of thin section images of the lung parenchyma. Three radiologists compared the UHSFA and HSFA on identical CT images in a line-pair resolution phantom, one lung specimen, 2 patients with normal lung and 18 patients with abnormal lung parenchyma. Scanning of a line-pair resolution phantom demonstrated no difference in resolution between two techniques but it showed that outer lines of the line pairs with maximal resolution looked thicker on UHSFA than those on HSFA. Lung parenchymal detail with UHSFA was judged equal or superior to HSFA in 95% of images. Lung parenchymal sharpness was improved with UHSFA in all images. Although UHSFA resulted in an increase in visible noise, observers did not found that image noise interfered with image interpretation. The visual CT attenuation of normal lung parenchyma is minimally increased in images with HSFA. The overall visual preference of the images reconstructed on UHSFA was considered equal to or greater than that of those reconstructed on HSFA in 78% of images. The ultrahigh spatial frequency algorithm improved the overall visual quality of the images in pulmonary parenchymal high-resolution CT

  16. High-resolution CT in eosinophilic granuloma (histiocytosis X) of the lung

    International Nuclear Information System (INIS)

    Godwin, J.D.; Buschman, D.L.; Moore, A.D.A.; Muller, N.L.; Naidich, D.P.; Carvalho, C.R.R.; Takasugi, J.E.; Schmidt, R.A.

    1988-01-01

    Eosinophilic granuloma of the lung is fascinating but poorly understood. Computed tomographic (CT) scans in 18 cases (11 high resolution) showed a variety of striking patterns: cysts up to 4 cm with thin or indiscernible walls, ranging from a few lesions to confluent honeycombing; retriculonodular infiltrate; and nodules 2 mm-2cm, sometimes cavitated. CT showed that the ill-defined lucencies barely visible on radiographs are indeed cysts, rather than preserved normal lung surrounded by infiltrate. High-resolution CT showed that some of the early, small nodules were concentrated along terminal bronchioles within the secondary lobules. The differential diagnosis includes sarcoidosis and idiopathic fibrosis, but the prominent cystic abnormality and the lack of peripheral concentration help to distinguish eosinophilic granuloma

  17. Development of high resolution x-ray CT technique for irradiated fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Ishimi, Akihiro; Katsuyama, Kozo; Maeda, Koji; Asaga, Takeo [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

    2012-03-15

    High X-ray CT technique was developed to observe the irradiation performance of FBR fuel assembly and MOX fuel. In this technique, the high energy X-ray pulse (12MeV) was used synchronizing detection system with the X-ray pulse to reduce the effect of the gamma ray emissions from the irradiated fuel assembly. In this study, this technique was upgraded to obtain high resolution X-ray CT image. In this upgrading, the collimator which had slit width of 0.1 mm and X-ray detector of a highly sensitive silicon semiconductor detector (100 channels) was introduced in the X-ray CT system. As a result of these developments, high resolution X-ray CT images could be obtained on the transverse cross section of irradiated fuel assembly. (author)

  18. Evaluation of patient absorbed dose in a PET-CT test

    International Nuclear Information System (INIS)

    Guerra P, F.; Mourao F, A. P.; Santana, P. C.

    2017-10-01

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg 18 F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the 18 F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  19. Evaluation of patient absorbed dose in a PET-CT test

    Energy Technology Data Exchange (ETDEWEB)

    Guerra P, F.; Mourao F, A. P. [Federal University of Minas Gerais, Department of Nuclear Engineering, Av. Antonio Carlos 6627, CEP 31270-901, Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P. C., E-mail: fgpaiva92@gmail.com [Federal University of Minas Gerais, Medical School, Av. Prof. Alfredo Balena 190, CEP 30123970, Santa Efigenia, Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg {sup 18}F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the {sup 18}F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  20. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  1. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  2. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  3. SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V; Zhang, J; Bruner, A [University of Kentucky, Lexington, KY (United States)

    2015-06-15

    Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

  4. Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT

    Science.gov (United States)

    Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.

    1993-07-01

    We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.

  5. Evaluation of the low dose cardiac CT imaging using ASIR technique

    Science.gov (United States)

    Fan, Jiahua; Hsieh, Jiang; Deubig, Amy; Sainath, Paavana; Crandall, Peter

    2010-04-01

    Today Cardiac imaging is one of the key driving forces for the research and development activities of Computed Tomography (CT) imaging. It requires high spatial and temporal resolution and is often associated with high radiation dose. The newly introduced ASIR technique presents an efficient method that offers the dose reduction benefits while maintaining image quality and providing fast reconstruction speed. This paper discusses the study of image quality of the ASIR technique for Cardiac CT imaging. Phantoms as well as clinical data have been evaluated to demonstrate the effectiveness of ASIR technique for Cardiac CT applications.

  6. The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures

    Energy Technology Data Exchange (ETDEWEB)

    Pyka, Grzegorz, E-mail: gregory.pyka@mtm.kuleuven.be [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium); Kerckhofs, Greet [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium); Biomechanics Research Unit, Université de Liege, Chemin des Chevreuils 1 - BAT 52/3, B-4000 Liège (Belgium); Schrooten, Jan; Wevers, Martine [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – PB2450, B-3001 Leuven (Belgium)

    2014-01-15

    In material science microfocus X-ray computed tomography (micro-CT) is one of the most popular non-destructive techniques to visualise and quantify the internal structure of materials in 3D. Despite constant system improvements, state-of-the-art micro-CT images can still hold several artefacts typical for X-ray CT imaging that hinder further image-based processing, structural and quantitative analysis. For example spatial resolution is crucial for an appropriate characterisation as the voxel size essentially influences the partial volume effect. However, defining the adequate image resolution is not a trivial aspect and understanding the correlation between scan parameters like voxel size and the structural properties is crucial for comprehensive material characterisation using micro-CT. Therefore, the objective of this study was to evaluate the influence of the spatial image resolution on the micro-CT based morphological analysis of three-dimensional (3D) open porous structures with a high surface complexity. In particular the correlation between the local surface properties and the accuracy of the micro-CT-based macro-morphology of 3D open porous Ti6Al4V structures produced by selective laser melting (SLM) was targeted and revealed for rough surfaces a strong dependence of the resulting structure characteristics on the scan resolution. Reducing the surface complexity by chemical etching decreased the sensitivity of the overall morphological analysis to the spatial image resolution and increased the detection limit. This study showed that scan settings and image processing parameters need to be customized to the material properties, morphological parameters under investigation and the desired final characteristics (in relation to the intended functional use). Customization of the scan resolution can increase the reliability of the micro-CT based analysis and at the same time reduce its operating costs. - Highlights: • We examine influence of the image resolution

  7. Super resolution reconstruction of μ-CT image of rock sample using neighbour embedding algorithm

    Science.gov (United States)

    Wang, Yuzhu; Rahman, Sheik S.; Arns, Christoph H.

    2018-03-01

    X-ray computed tomography (μ-CT) is considered to be the most effective way to obtain the inner structure of rock sample without destructions. However, its limited resolution hampers its ability to probe sub-micro structures which is critical for flow transportation of rock sample. In this study, we propose an innovative methodology to improve the resolution of μ-CT image using neighbour embedding algorithm where low frequency information is provided by μ-CT image itself while high frequency information is supplemented by high resolution scanning electron microscopy (SEM) image. In order to obtain prior for reconstruction, a large number of image patch pairs contain high- and low- image patches are extracted from the Gaussian image pyramid generated by SEM image. These image patch pairs contain abundant information about tomographic evolution of local porous structures under different resolution spaces. Relying on the assumption of self-similarity of porous structure, this prior information can be used to supervise the reconstruction of high resolution μ-CT image effectively. The experimental results show that the proposed method is able to achieve the state-of-the-art performance.

  8. Thin-slice high-resolution CT study of pulmonary asbestosis and idiopathic interstitial pneumonia

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki; Maeda, Munehiro; Ohmura, Takuya

    1987-01-01

    Thin-slice high-resolution CT findings were compared between 36 patients with pulmonary asbestos exposure (AS) and 33 patients with idiopathic interstitial pneumonia (IIP). The CT scans of these patients were classified into 5 types (0-IV) by the subpleural curvilinear shadow (SCLS) and honey-comb shadow (HS). SCLS was detected in 22 (62 %) patients with AS and 7 (21 %) with IIP. HS was detected in 14 (39 %) patients with AS and 33 (100 %) with IIP. In both the diseases, SCLS was distributed mainly in the lower lobe in CT types I and II, and in mildly fibrotic segments in types III and IV. In CT types II, III and IV, SCLS was always communicated with HS. Thin-slice high-resolution CT is considered very helpful in diagnosis and staging of not only AS and IIP but also pulmonary fibrosis. (author)

  9. Evaluation of the efficiency of FDG PET/CT in detection and characterization of skeletal metastases

    Directory of Open Access Journals (Sweden)

    Ahmed Wafaie

    2014-03-01

    Conclusion: Fused PET/CT was highly efficient in evaluation of skeletal metastases with superior performance in: detection of early bone marrow infiltration not apparent on CT, resolution of metabolic activity before definite signs of complete healing on CT, detection of missed sclerotic metastases on PET due to their relatively low metabolic activity, detection of intra and extra osseous recurrence and differentiation of benign from malignant bone lesions.

  10. Ultra-high-resolution CT angiography of the artery of Adamkiewicz. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Kunihiro; Tanaka, Ryoichi; Takagi, Hidenobu [Iwate Medical University, Division of Cardiovascular Radiology, Department of Radiology, Morioka (Japan); Ueyama, Yuta; Kikuchi, Kei; Chiba, Takuya [Iwate Medical University Hospital, Center for Radiological Science, Morioka (Japan); Arakita, Kazumasa [Center for Medical Research and Development, Toshiba Medical Systems Corporation, Otawara (Japan); Schuijf, Joanne D. [Center for Medical Research and Development Europe, Toshiba Medical Systems Europe, Zoetermeer (Netherlands); Saito, Yasuo [CT Systems Development Department, Toshiba Medical Systems Corporation, Otawara (Japan)

    2018-01-15

    Preoperative identification of the artery of Adamkiewicz can help prevent postoperative spinal cord injury following thoracic and thoracoabdominal aortic repair. Several studies have demonstrated the feasibility of evaluating the artery of Adamkiewicz using multi-detector row computed tomography (CT), but precise visualization remains a challenge. The present study was conducted to evaluate the usefulness of ultra-high-resolution CT for visualizing the artery of Adamkiewicz with a slice thickness of 0.25 versus 0.5 mm in patients with aortic aneurysms. Our institutional review board approved this study. Twenty-four patients with thoracic and thoracoabdominal aneurysms were scanned with beam collimation of 0.25 mm x 128. Images were reconstructed with slice thicknesses of 0.25 and 0.5 mm. The signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) between the anterior spinal artery and spinal cord were measured. Two independent observers evaluated visualization of the artery of Adamkiewicz and its continuity between the anterior spinal artery and the aorta using a four-point scale. No significant differences in the SNR of the aorta or CNR of the anterior spinal artery were observed between 0.25- and 0.5-mm slices. The average visualization score was significantly higher for 0.25-mm slices (3.58 ± 0.78) than for 0.5-mm slices (3.13 ± 0.99) (p = 0.01). The percentage of patients with nondiagnostic image quality was significantly lower for 0.25-mm slices (8.3%) than for 0.5-mm slices (33.3%) (p = 0.03). In patients with aortic aneurysms, ultra-high-resolution CT with 0.25-mm slices significantly improves visualization of the artery of Adamkiewicz compared to 0.5-mm slices. (orig.)

  11. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.

    Science.gov (United States)

    Matenine, Dmitri; Mascolo-Fortin, Julia; Goussard, Yves; Després, Philippe

    2015-11-01

    The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of

  12. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  13. TH-EF-207A-06: High-Resolution Optical-CT/ECT Imaging of Unstained Mice Femur, Brain, Spleen, and Tumor

    International Nuclear Information System (INIS)

    Yoon, S; Dewhirst, M; Oldham, M; Boss, M; Birer, S

    2016-01-01

    Purpose: Optical transmission and emission computed tomography (optical-CT/ECT) provides high-resolution 3D attenuation and emission maps in unsectioned large (∼1cm 3 ) ex vivo tissue samples at a resolution of 12.9µm 3 per voxel. Here we apply optical-CT/ECT to investigate high-resolution structure and auto-fluorescence in a range of optically cleared mice organs, including, for the first time, mouse bone (femur), opening the potential for study of bone metastasis and bone-mediated immune response. Methods: Three BALBc mice containing 4T1 flank tumors were sacrificed to obtain spleen, brain, tumor, and femur. Tissues were washed in 4% PFA, fixed in EtOH solution (for 5, 10, 10, and 2 days respectively), and then optically cleared for 3 days in BABBs. The femur was also placed in 0.25M aqueous EDTA for 15–30 days to remove calcium. Optical-CT/ECT attenuation and emission maps at 633nm (the latter using 530nm excitation light) were obtained for all samples. Bi-telecentric optical-CT was compared side-by-side with conventional optical projection tomography (OPT) imaging to evaluate imaging capability of these two rival techniques. Results: Auto-fluorescence mapping of femurs reveals vasculatures and fluorescence heterogeneity. High signals (A.U.=10) are reported in the medullary cavity but not in the cortical bone (A.U.=1). The brain strongly and uniform auto-fluoresces (A.U.=5). Thick, optically dense organs such as the spleen and the tumor (0.12, 0.46OD/mm) are reconstructed at depth without significant loss of resolution, which we attribute to the bi-telecentric optics of optical-CT. The attenuation map of tumor reveals vasculature, attenuation heterogeneity, and possibly necrotic tissue. Conclusion: We demonstrate the feasibility of optical-CT/ECT imaging of un-sectioned mice bones (femurs) and spleen with high resolution. This result, and the characterization of unstained organs, are important steps enabling future studies involving optical-CT/ECT applied

  14. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  15. Lipoid pneumonia in children following aspiration of mineral oil used in the treatment of constipation: high-resolution CT findings in 17 patients

    International Nuclear Information System (INIS)

    Zanetti, Glaucia; Marchiori, Edson; Gasparetto, Taisa D.; Escuissato, Dante L.; Soares Souza, Arthur

    2007-01-01

    Exogenous lipoid pneumonia is a rare disorder caused by aspiration of mineral, vegetable and animal oils. High-resolution CT findings of lipoid pneumonia in children taking mineral oil for constipation have been rarely reported. To evaluate the high-resolution CT findings in 17 children with exogenous lipoid pneumonia following aspiration of mineral oil. The study included nine boys and eight girls, with ages ranging from 2 months to 9 years. All patients underwent high-resolution CT and the images were reviewed by two radiologists who reached decisions by consensus. The inclusion criteria were an abnormal radiograph, history of taking mineral oil and the presence of intrapulmonary lipids proved by bronchoalveolar lavage or open lung biopsy. The most common symptoms were cough (n = 13), mild fever (n = 11), and progressive dyspnea (n = 9). The main CT findings were air-space consolidations (100%), usually with areas of fatty attenuation (70.6%), areas of ground-glass attenuation (52.9%), and a crazy-paving pattern (17.6%), predominating bilaterally in the posterior and lower regions of the lungs. The high-resolution CT features in children with exogenous lipoid pneumonia are air-space consolidations and ground-glass attenuation, occasionally with a crazy-paving pattern, distributed bilaterally in the posterior and lower zones of the lungs. (orig.)

  16. Lipoid pneumonia in children following aspiration of mineral oil used in the treatment of constipation: high-resolution CT findings in 17 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zanetti, Glaucia [University of Rio de Janeiro, Department of Radiology, Rio de Janeiro (Brazil); Marchiori, Edson [University of Rio de Janeiro, Department of Radiology, University Federal Fluminense, Rio de Janeiro (Brazil); Gasparetto, Taisa D. [University Federal Fluminense, Department of Radiology, Rio de Janeiro (Brazil); Escuissato, Dante L. [University of Parana, Department of Radiology, Curitiba (Brazil); Soares Souza, Arthur [School of Medicine of Sao Jose do Rio Preto (ASSJ), Department of Radiology, Sao Jose do Rio Preto (Brazil)

    2007-11-15

    Exogenous lipoid pneumonia is a rare disorder caused by aspiration of mineral, vegetable and animal oils. High-resolution CT findings of lipoid pneumonia in children taking mineral oil for constipation have been rarely reported. To evaluate the high-resolution CT findings in 17 children with exogenous lipoid pneumonia following aspiration of mineral oil. The study included nine boys and eight girls, with ages ranging from 2 months to 9 years. All patients underwent high-resolution CT and the images were reviewed by two radiologists who reached decisions by consensus. The inclusion criteria were an abnormal radiograph, history of taking mineral oil and the presence of intrapulmonary lipids proved by bronchoalveolar lavage or open lung biopsy. The most common symptoms were cough (n = 13), mild fever (n = 11), and progressive dyspnea (n = 9). The main CT findings were air-space consolidations (100%), usually with areas of fatty attenuation (70.6%), areas of ground-glass attenuation (52.9%), and a crazy-paving pattern (17.6%), predominating bilaterally in the posterior and lower regions of the lungs. The high-resolution CT features in children with exogenous lipoid pneumonia are air-space consolidations and ground-glass attenuation, occasionally with a crazy-paving pattern, distributed bilaterally in the posterior and lower zones of the lungs. (orig.)

  17. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  18. High-resolution CT findings in infants with bronchopulmonary dysplasia: preliminary report

    International Nuclear Information System (INIS)

    Chung, Yoon Ho; Lee, Young Seok; Kim, Ji Hye; Han, Heon; Chung, Hyo Sun; Cha, Yoo Mi; Kim, Young Chae; Kim, Sang Hee

    1996-01-01

    To evaluate high resolution CT(HRCT) findings in infants with bronchopulmonary dysplasia(BPD). In 13 infants(age range, 1-12 months;11 premature babies, two full-term babies; birth weight, 0.97-3.88kg;mean 2,03kg) with clinico-radiologically suggested BPD, HRCT findings of the lung were reviewed retrospectively. Spiral CT using ultra high bone algorithm, 1mm collimation with 5-8mm interval, and 0.7sec scan time was performed without regard to breathing-control of infants. Three radiologists each analysed the HRCT findings twice. HRCT findings of BPD were as follows:parenchymal bands(n=13), interlobular septal thickenings (n=12), multifocal hyperaeration involving lobar or segmental distribution(n=7), and involving lobular distribution or small cyst-like lesion(n=4), centrilobular nodules(n=7), consolidation and/or atelectasis(n=7), and bronchovascular bundle thickening(n=6). Parenchymal bands, interlobular septal thickenings, and multifocal hyperaerations were the major findings in cases of bronchopulmonary dysplasia whereas, centrilobular nodules, consolidation and/or atelectasis, and bronchovascular bundle thickenings were the minor findings. These findings may be used as basic data in the evaluation of BPD in future studies

  19. Bronchiolitis obliterans in children with Stevens-Johnson syndrome: follow-up with high resolution CT

    International Nuclear Information System (INIS)

    Kim, M.J.; Lee, K.Y.

    1996-01-01

    About one third of children with Stevens-Johnson syndrome have pulmonary involvement. As a consequence of airway epithelial injury, bronchiolitis obliterans can occur in these patients. Two cases of Stevens-Johnson syndrome-associated bronchiolitis obliterans in children were diagnosed and followed by high resolution CT without open lung biopsy. Serial changes of high resolution CT features of bronchiolitis obliterans are discussed and the literature is reviewed. (orig.)

  20. Crackle analysis for chest auscultation and comparison with high-resolution CT findings.

    Science.gov (United States)

    Kawamura, Takeo; Matsumoto, Tsuneo; Tanaka, Nobuyuki; Kido, Shoji; Jiang, Zhongwei; Matsunaga, Naofumi

    2003-01-01

    The purpose of our study was to clarify the correlation between respiratory sounds and the high-resolution CT (HRCT) findings of lung diseases. Respiratory sounds were recorded using a stethoscope in 41 patients with crackles. All had undergone inspiratory and expiratory CT. Subjects included 18 patients with interstitial pneumonia and 23 without interstitial pneumonia. Two parameters, two-cycle duration (2CD) and initial deflection width (IDW) of the "crackle," were induced by time-expanded waveform analysis. Two radiologists independently assessed 11 HRCT findings. An evaluation was carried out to determine whether there was a significant difference in the two parameters between the presence and absence of each HRCT finding. The two parameters of crackles were significantly shorter in the interstitial pneumonia group than the non-interstitial pneumonia group. Ground-glass opacity, honeycombing, lung volume reduction, traction bronchiectasis, centrilobular nodules, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were correlated with one or two parameters in all patients, whereas the other three findings were not. Among the interstitial pneumonia group, traction bronchiectasis, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were significantly correlated with one or two parameters. Abnormal respiratory sounds were correlated with some HRCT findings.

  1. Crackle analysis for chest auscultation and comparison with high-resolution CT findings

    International Nuclear Information System (INIS)

    Kawamura, Takeo; Matsumoto, Tsuneo; Tanaka, Nobuyuki; Matsunaga, Naofumi; Kido, Shoji; Jiang Zhongwei

    2003-01-01

    The purpose of our study was to clarify the correlation between respiratory sounds and the high-resolution CT (HRCT) findings of lung diseases. Respiratory sounds were recorded using a stethoscope in 41 patients with crackles. All had undergone inspiratory and expiratory CT. Subjects included 18 patients with interstitial pneumonia and 23 without interstitial pneumonia. Two parameters, two-cycle duration (2CD) and initial deflection width (IDW) of the ''crackle,'' were induced by time-expanded waveform analysis. Two radiologists independently assessed 11 HRCT findings. An evaluation was carried out to determine whether there was a significant difference in the two parameters between the presence and absence of each HRCT finding. The two parameters of crackles were significantly shorter in the interstitial pneumonia group than the non-interstitial pneumonia group. Ground-glass opacity, honeycombing, lung volume reduction, traction bronchiectasis, centrilobular nodules, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were correlated with one or two parameters in all patients, whereas the other three findings were not. Among the interstitial pneumonia group, traction bronchiectasis, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were significantly correlated with one or two parameters. Abnormal respiratory sounds were correlated with some HRCT findings. (author)

  2. Examination of the fine interstitial changes of pneumoconiosis with high resolution computed tomography (HR-CT)

    International Nuclear Information System (INIS)

    Kido, Masamitsu; Miyazaki, Nobuyoshi; Harada, Susumu; Nakata, Hajime

    1986-01-01

    High resolution CT was performed in 14 patients with fine interstitial changes of pneumoconiosis and Review image was evaluated for the diagnostic accuracy as compared with conventional chest roentgenogram. Of the 14 Patients in the study, 7 were divided category 1 by the ILO U/C classification, 4 were category 2, 3 were category 3. Studies of lung function showed obstructive ventilatory disturbance characterized by moderate reduction in FEV 1.0% (58.6 ± 16.5 %) and V25/H (0.34 ± 0.24 l/sec/m). HR-CT defined more sensitive in the presence of fine lung nodules than conventional X-p, and showed high contrast interfaces provided by the aerated lung. HR-CT was also of value in detecting bulla, bleb, peripleural changes and hilar lymphadenopathy. Radiologic-pathologic correlation was examined on tne specimens of transbronchial lung biopsy in 4 patients, and revealed the diagnostic usefullness of HR-CT. (author)

  3. An unusual case of left aberrant innominate artery with right aortic arch: evaluation with high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio [University Rene Descartes-Paris 5, Department of Pediatric Cardiology, Hopital Necker Enfants Malades, Paris (France); Gesualdo, Francesco; Brunelle, Francis; Ou, Phalla [University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker Enfants Malades, Paris Cedex 15 (France)

    2008-01-15

    A left aberrant innominate (brachiocephalic) artery is an angiographically well-known entity that may cause tracheal compression. We report a male newborn who was admitted for further investigation of a prenatally suspected major vessel anomaly. High-resolution CT was used to completely assess the abnormal anatomy and the relationship with the airway, as well as to guide the surgical approach for its correction. (orig.)

  4. An unusual case of left aberrant innominate artery with right aortic arch: evaluation with high-resolution CT

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Gesualdo, Francesco; Brunelle, Francis; Ou, Phalla

    2008-01-01

    A left aberrant innominate (brachiocephalic) artery is an angiographically well-known entity that may cause tracheal compression. We report a male newborn who was admitted for further investigation of a prenatally suspected major vessel anomaly. High-resolution CT was used to completely assess the abnormal anatomy and the relationship with the airway, as well as to guide the surgical approach for its correction. (orig.)

  5. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    Energy Technology Data Exchange (ETDEWEB)

    Panetta, Daniele [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Belcari, Nicola [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy); Tripodi, Maria [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Burchielli, Silvia [Fondazione CNR/Toscana “G. Monasterio” – FTGM, v. G. Moruzzi 1, I-56124 Pisa (Italy); Salvadori, Piero A. [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Del Guerra, Alberto [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy)

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI{sub 100} has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R{sup 2}>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  6. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    Science.gov (United States)

    Panetta, Daniele; Belcari, Nicola; Tripodi, Maria; Burchielli, Silvia; Salvadori, Piero A.; Del Guerra, Alberto

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI100 has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R2>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  7. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    International Nuclear Information System (INIS)

    Panetta, Daniele; Belcari, Nicola; Tripodi, Maria; Burchielli, Silvia; Salvadori, Piero A.; Del Guerra, Alberto

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI_1_0_0 has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R"2>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  8. Pulmonary lymphangioleiomyomatosis: high-resolution CT findings

    International Nuclear Information System (INIS)

    Kirchner, J.; Stein, A.; Thalhammer, A.; Jacobi, V.

    1999-01-01

    Lymphangioleiomyomatosis (LAM) of the lung is a very rare disease. There are obvious discrepancies in the literature concerning the appearance of LAM on CT scans of the lung. This study adds the imaging findings of 11 patients and demonstrates how the imaging findings changed over time in four patients. Twenty-two CT examinations, and radiographs that had been obtained close to the CT examinations, of 11 patients with LAM confirmed by open lung biopsy were retrospectively evaluated with particular attention to the size of cystic lesions and wall thickness. Furthermore the CT scans were analysed for the type of pulmonary infiltration process and its distribution, presence or absence of pleural effusion, pneumothorax and lymph node enlargement. Clinical and CT follow-up studies were available in four patients. The CT scans revealed an increase in the interstitial pattern in all patients. Architectural distortion was seen in two patients and cystic lesions were present in all. The size of the cysts varied from small lesions to bullous emphysema. The cystic lesions revealed a wall thickness up to 2 mm but a wall was not perceptible in all. Pneumothorax was seen in only two patients; pleural effusion was seen in two patients. CT examination of patients with LAM reveals neither a uniform nor a pathognomonic appearance. In the early stages of LAM or in cases with interstitial changes the differential diagnosis of centrilobular emphysema or idiopathic pulmonary fibrosis seems to be more difficult than most authors believe. (orig.) (orig.)

  9. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  10. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  11. High resolution CT in children with cystic fibrosis

    International Nuclear Information System (INIS)

    Stiglbauer, R.; Schurawitzki, H.; Eichler, I.; Goetz, M.

    1992-01-01

    High resolution CT (HRCT) was performed in 24 children (median age 57.9 months) suffering from cystic fibrosis (CF). In 23 patients (one examination unacceptable because of motion artifacts) the most frequent finding was bronchial wall thickening, shown in 21 patients (91%), followed by bronchiectasis in 15 patients (65%). Less frequent findings were mucus plugging and patchy consolidations, which could be demonstrated in 11 patients each (48%). Findings were classified using a CT scoring system and including only irreversible pulmonary changes; a statistically significant correlation with lung function tests could be established. HRCT to date seems to be the most valuable method to determine extent and severity of lung involvement in children with CF and should therefore be routinely used for the staging of this disease. (orig.)

  12. Pulmonary lymphangioleiomyomatosis: high-resolution CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, J.; Stein, A.; Thalhammer, A.; Jacobi, V. [Mainz Univ. (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Viel, K.; Dietrich, C.F. [Frankfurt Univ. (Germany). Medizinische Klinik II; Schneider, M. [Zentrum fuer Pathologie, Frankfurt Univ. (Germany)

    1999-02-01

    Lymphangioleiomyomatosis (LAM) of the lung is a very rare disease. There are obvious discrepancies in the literature concerning the appearance of LAM on CT scans of the lung. This study adds the imaging findings of 11 patients and demonstrates how the imaging findings changed over time in four patients. Twenty-two CT examinations, and radiographs that had been obtained close to the CT examinations, of 11 patients with LAM confirmed by open lung biopsy were retrospectively evaluated with particular attention to the size of cystic lesions and wall thickness. Furthermore the CT scans were analysed for the type of pulmonary infiltration process and its distribution, presence or absence of pleural effusion, pneumothorax and lymph node enlargement. Clinical and CT follow-up studies were available in four patients. The CT scans revealed an increase in the interstitial pattern in all patients. Architectural distortion was seen in two patients and cystic lesions were present in all. The size of the cysts varied from small lesions to bullous emphysema. The cystic lesions revealed a wall thickness up to 2 mm but a wall was not perceptible in all. Pneumothorax was seen in only two patients; pleural effusion was seen in two patients. CT examination of patients with LAM reveals neither a uniform nor a pathognomonic appearance. In the early stages of LAM or in cases with interstitial changes the differential diagnosis of centrilobular emphysema or idiopathic pulmonary fibrosis seems to be more difficult than most authors believe. (orig.) (orig.) With 5 figs., 2 tabs., 21 refs.

  13. High spatial resolution CT image reconstruction using parallel computing

    International Nuclear Information System (INIS)

    Yin Yin; Liu Li; Sun Gongxing

    2003-01-01

    Using the PC cluster system with 16 dual CPU nodes, we accelerate the FBP and OR-OSEM reconstruction of high spatial resolution image (2048 x 2048). Based on the number of projections, we rewrite the reconstruction algorithms into parallel format and dispatch the tasks to each CPU. By parallel computing, the speedup factor is roughly equal to the number of CPUs, which can be up to about 25 times when 25 CPUs used. This technique is very suitable for real-time high spatial resolution CT image reconstruction. (authors)

  14. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  15. Evaluation of the Meditech M250 and a comparison with other CT scanners

    Energy Technology Data Exchange (ETDEWEB)

    Greensmith, R.; Richardson, R.B.; Mackintosh, I.P.; Sargood, A.J.; Stevens, P.H.

    1985-11-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability.

  16. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    International Nuclear Information System (INIS)

    Gupta, Rajiv; Brady, Tom; Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas; Bartling, Soenke H.

    2006-01-01

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  17. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Rajiv; Brady, Tom [Massachusetts General Hospital, Department of Radiology, Founders House, FND-2-216, Boston, MA (United States); Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas [Siemens Medical Solutions, Forchheim (Germany); Bartling, Soenke H. [Hannover Medical School, Department of Neuroradiology, Hannover (Germany)

    2006-06-15

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  18. Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering

    Science.gov (United States)

    Lienemann, Philipp S.; Metzger, Stéphanie; Kiveliö, Anna-Sofia; Blanc, Alain; Papageorgiou, Panagiota; Astolfo, Alberto; Pinzer, Bernd R.; Cinelli, Paolo; Weber, Franz E.; Schibli, Roger; Béhé, Martin; Ehrbar, Martin

    2015-05-01

    Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.

  19. The frequency and the degree of fusion of the lung on high-resolution CT

    International Nuclear Information System (INIS)

    Shin, Hwan Sik; Kim, Sung Jin; Bae, Il Hun; Song, Kyung Sup; Kim, Joo Chang; Han, Ki Suk; Cha, Sang Hoon; Park, Kil Sun

    2000-01-01

    To evaluate the frequency and degree of fusion of the lung as seen on high-resolution CT (HRCT). In 210 patients high-resolution CT scans from the apex to the diaphragm were obtained at 1 mm collimation and 7 mm interval. We retrospectively analysed the frequency and degree of fusion of the lung bordering each interlobar fissure. Fusion of the lung was defined when fissure appeared without complete lobar separation. The degree of lung fusion was classified as mild (less than 1/3 of the fissure), moderate (greater than 1/3 and less than 2/3 of fissure), or severe (greater than 2/3 of the fissure). In 90 of 210 patients, all fissures were identified. In 73 of these 90 (81.1%), lung fusion was noted, the most frequent site of this being between the right upper and right middle lobe (53.3%) . The least frequent site was between the upper portion of the left upper and left lower lobe (32.2%). Am mild degree of fusion was most frequently found between the right middle and right lower lobe (83.9%0, while a severe degree was most frequent between the right middle and right upper lobe (50.0%), followed by the lingular division and the left lower lobe (41.9%). HRCT can be used to evaluate the frequency and degree of interlobar lung fusion. (author)

  20. WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

    International Nuclear Information System (INIS)

    Montoya, J; Ferrero, A; Yu, L; Leng, S; McCollough, C

    2016-01-01

    Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150 and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare

  1. WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

    Energy Technology Data Exchange (ETDEWEB)

    Montoya, J; Ferrero, A; Yu, L; Leng, S; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2016-06-15

    Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150 and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.

  2. Finite detector based projection model for super resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hengyong; Wang, Ge [Wake Forest Univ. Health Sciences, Winston-Salem, NC (United States). Dept. of Radiology; Virgina Tech, Blacksburg, VA (United States). Biomedical Imaging Div.

    2011-07-01

    For finite detector and focal spot sizes, here we propose a projection model for super resolution CT. First, for a given X-ray source point, a projection datum is modeled as an area integral over a narrow fan-beam connecting the detector elemental borders and the X-ray source point. Then, the final projection value is expressed as the integral obtained in the first step over the whole focal spot support. An ordered-subset simultaneous algebraic reconstruction technique (OS-SART) is developed using the proposed projection model. In the numerical simulation, our method produces super spatial resolution and suppresses high-frequency artifacts. (orig.)

  3. Vanishing lung syndrome: the importance of the high-resolution CT in its diagnostic

    International Nuclear Information System (INIS)

    Rodriguez Cerezo, M.I.; Porres Azcona, E.; Pina Insausti, L.; Inchusta Sarasibar, M.I.; Mellado Rodriguez, M.

    1995-01-01

    Vanishing lung syndrome, also referred to as idiopathic giant bullions emphysema is a dissolver that has yet to be fully characterized. It is considered a different entry from classic pulmonary emphysema. It is characterized by the presence of large bullae associated with some type of emphysema. High-resolution CT is the best imaging technique to identify the underlying type of emphysema and it helps to determine the viability of the nonbullous lung. We present the case of an asymptomatic patient in whom the diagnosis was suspected on the basis of plain chest X ray and was confirmed by high-resolution CT. 13 refs

  4. Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Lifeng, E-mail: yu.lifeng@mayo.edu; Vrieze, Thomas J.; Leng, Shuai; Fletcher, Joel G.; McCollough, Cynthia H. [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-05-15

    Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

  5. High-resolution CT with histopathological correlates of the classic metaphyseal lesion of infant abuse

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Andy; Kleinman, Paul K. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); McDonald, Anna G. [Office of the Chief Medical Examiner, Boston, MA (United States); Rosenberg, Andrew E. [University of Miami Hospital, Department of Pathology, Miami, FL (United States); Gupta, Rajiv [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States)

    2014-02-15

    The classic metaphyseal lesion (CML) is a common high specificity indicator of infant abuse and its imaging features have been correlated histopathologically in infant fatalities. High-resolution CT imaging and histologic correlates were employed to (1) characterize the normal infant anatomy surrounding the chondro-osseous junction, and (2) confirm the 3-D model of the CML previously inferred from planar radiography and histopathology. Long bone specimens from 5 fatally abused infants, whose skeletal survey showed definite or suspected CMLs, were studied postmortem. After skeletal survey, selected specimens were resected and imaged with high-resolution digital radiography. They were then scanned with micro-CT (isotropic resolution of 45 μm{sup 3}) or with high-resolution flat-panel CT (isotropic resolutions of 200 μm{sup 3}). Visualization of the bony structures was carried out using image enhancement, segmentation and isosurface extraction, together with volume rendering and multiplanar reformatting. These findings were then correlated with histopathology. Study of normal infant bone clarifies the 3-D morphology of the subperiosteal bone collar (SPBC) and the radiographic zone of provisional calcification (ZPC). Studies on specimens with CML confirm that this lesion is a fracture extending in a planar fashion through the metaphysis, separating a mineralized fragment. This disk-like mineralized fragment has two components: (1) a thick peripheral component encompassing the SPBC; and (2) a thin central component comprised predominantly of the radiologic ZPC. By manipulating the 3-D model, the varying appearances of the CML are displayed. High-resolution CT coupled with histopathology provides elucidation of the morphology of the CML, a strong indicator of infant abuse. This new information may prove useful in assessing the biomechanical factors that produce this strong indicator of abusive assaults in infants. (orig.)

  6. High-resolution CT with histopathological correlates of the classic metaphyseal lesion of infant abuse

    International Nuclear Information System (INIS)

    Tsai, Andy; Kleinman, Paul K.; McDonald, Anna G.; Rosenberg, Andrew E.; Gupta, Rajiv

    2014-01-01

    The classic metaphyseal lesion (CML) is a common high specificity indicator of infant abuse and its imaging features have been correlated histopathologically in infant fatalities. High-resolution CT imaging and histologic correlates were employed to (1) characterize the normal infant anatomy surrounding the chondro-osseous junction, and (2) confirm the 3-D model of the CML previously inferred from planar radiography and histopathology. Long bone specimens from 5 fatally abused infants, whose skeletal survey showed definite or suspected CMLs, were studied postmortem. After skeletal survey, selected specimens were resected and imaged with high-resolution digital radiography. They were then scanned with micro-CT (isotropic resolution of 45 μm 3 ) or with high-resolution flat-panel CT (isotropic resolutions of 200 μm 3 ). Visualization of the bony structures was carried out using image enhancement, segmentation and isosurface extraction, together with volume rendering and multiplanar reformatting. These findings were then correlated with histopathology. Study of normal infant bone clarifies the 3-D morphology of the subperiosteal bone collar (SPBC) and the radiographic zone of provisional calcification (ZPC). Studies on specimens with CML confirm that this lesion is a fracture extending in a planar fashion through the metaphysis, separating a mineralized fragment. This disk-like mineralized fragment has two components: (1) a thick peripheral component encompassing the SPBC; and (2) a thin central component comprised predominantly of the radiologic ZPC. By manipulating the 3-D model, the varying appearances of the CML are displayed. High-resolution CT coupled with histopathology provides elucidation of the morphology of the CML, a strong indicator of infant abuse. This new information may prove useful in assessing the biomechanical factors that produce this strong indicator of abusive assaults in infants. (orig.)

  7. CT imaging of the internal human ear: Test of a high resolution scanner

    Energy Technology Data Exchange (ETDEWEB)

    Bettuzzi, M., E-mail: matteo.bettuzzi@unibo.it [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Brancaccio, R.; Morigi, M.P. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Gallo, A. [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Strolin, S.; Casali, F. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Lamanna, Ernesto [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Ariu, Marilu [CEFLA Dental Group, Imola (Italy)

    2011-08-21

    During the course of 2009, in the framework of a project supported by the National Institute of Nuclear Physics, a number of tests were carried out at the Department of Physics of the University of Bologna in order to achieve a good quality CT scan of the internal human ear. The work was carried out in collaboration with the local 'S. Orsola' Hospital in Bologna and a company (CEFLA) already involved in the production and commercialization of a CT scanner dedicated to dentistry. A laboratory scanner with a simple concept detector (CCD camera-lens-mirror-scintillator) was used to see to what extent it was possible to enhance the quality of a conventional CT scanner when examining the internal human ear. To test the system, some conventional measurements were made, such as the spatial resolution calculation with the MTF and dynamic range evaluation. Different scintillators were compared to select the most suitable for the purpose. With 0.5 mm thick structured cesium iodide and a field of view of 120x120 mm{sup 2}, a spatial resolution of 6.5l p/mm at 5% MTF was obtained. The CT of a pair of human head phantoms was performed at an energy of 120 kVp. The first phantom was a rough representation of the human head shape, with soft tissue made of coarse slabs of Lucite. Some inserts, like small aluminum cylinders and cubes, with 1 mm diameter drilled holes, were used to simulate the channels that one finds inside the human inner ear. The second phantom is a plastic PVC fused head with a real human cranium inside. The bones in the cranium are well conserved and the inner ear features, such as the cochlea and semicircular channels, are clearly detectable. After a number of CT tests we obtained good results as far as structural representation and channel detection are concerned. Some images of the 3D rendering of the CT volume are shown below. The doctors of the local hospital who followed our experimentation expressed their satisfaction. The CT was compared to a

  8. An evaluation of the Meditech M250 and a comparison with other CT scanners

    International Nuclear Information System (INIS)

    Greensmith, R.; Richardson, R.B.; Mackintosh, I.P.; Sargood, A.J.; Stevens, P.H.

    1985-01-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability. (author)

  9. An evaluation of the Meditech M250 and a comparison with other CT scanners.

    Science.gov (United States)

    Greensmith, R; Richardson, R B; Sargood, A J; Stevens, P H; Mackintosh, I P

    1985-11-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability.

  10. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  11. Performance evaluation of a 64-slice CT system with z-flying focal spot.

    Science.gov (United States)

    Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H

    2004-12-01

    The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG

  12. Role of high-resolution CT in the diagnosis of small pulmonary nodules coexisting with potentially operable lung cancer

    International Nuclear Information System (INIS)

    Yuan, Yue; Matsumoto, Tsuneo; Hiyama, Atsuto; Miura, Goji; Tanaka, Nobuyuki; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to evaluate whether high-resolution CT (HRCT) could facilitate the preoperative diagnosis of one or two small nodules of 1 cm or less coexisting with a lung cancer, i.e., coexisting small nodule. This study included 27 coexisting small nodules in 24 potentially operable lung cancer patients. An observer study was performed by five radiologists. The observer performances in differentiating malignant from benign coexisting small nodules were evaluated on conventional CT and HRCT using receiver operating characteristic (ROC) analysis. The area under the ROC curve of five observers was 0.731 on HRCT and 0.578 on conventional CT in the differential diagnosis of coexisting small nodules. A significant diagnostic improvement was found on HRCT (p=0.031). This was especially evident for nodules of ground-glass attenuation (p=0.005). HRCT plays an important role in determining the treatment of potentially operable lung cancer patients with coexisting small nodules. (author)

  13. Anatomy of the minor fissure: assessment with high-resolution CT and classification

    International Nuclear Information System (INIS)

    Ariyuerek, Macit O.; Yelgec, Selcuk N.; Guelsuen, Meltem; Karabulut, Nevzat

    2002-01-01

    The aims of this study were to investigate the anatomy of the minor fissure and its variations on high-resolution CT (HRCT) sections and to propose a detailed classification. The prospective study included 67 patients who were referred to CT for various indications. High-resolution CT examinations (1.5-mm collimation) were obtained through the region of the minor fissure. The CT scans were assessed for the presence, completeness, and configuration of the minor fissure. Various configurations of the minor fissure were classified into four major types, based on whether the highest portion of the middle lobe upper surface was medial (type I), lateral (type II), posterior (type III), or central (type IV). Minor fissure was identified in 65 (97%) of 67 patients, and absent in 2 (3%) cases. The fissure was incomplete in 35 (54%) of 65 patients. Type-I minor fissure is seen in 28 (43%) patients, type II in 22 (34%), type III in 5 (8%), and type IV in 2 (3%) patients. Because the majority of the fissure was absent in 8 (12%) of 35 patients with incomplete fissure, they were considered indeterminate. Comprehensive knowledge of the various configurations of the minor fissure is helpful in correct localization of a lesion and its extension. In equivocal cases, limited thin-section CT scans through the fissure delineate the anatomy more clearly and provide greater degree of precision in localizing pulmonary lesions. (orig.)

  14. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  15. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  16. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  17. Chronic pneumonitis of infancy: high-resolution CT findings

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.; Owens, Catherine M.; Sebire, Neil J.; Jaffe, Adam

    2004-01-01

    Chronic pneumonitis of infancy (CPI) is a very rare entity. We report the chest radiography and high-resolution CT (HRCT) findings in an infant with histopathologically confirmed CPI. The child was admitted for intensive care 18 h after birth and died at 39 days of age. On HRCT there was diffuse ground-glass change, interlobular septal thickening and discrete centrilobular nodules. An accurate diagnosis is crucial for correct management; however, several entities with the same HRCT findings are recognized. (orig.)

  18. Bronchiectasis: correlation of high-resolution CT findings with health-related quality of life

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, I. [Department of Diagnostic Radiology, E. Wolfson Medical Center, Holon (Israel)]. E-mail: iriseshed@gmail.com; Minski, I. [Department of Diagnostic Radiology, E. Wolfson Medical Center, Holon (Israel); Katz, R. [Department of Diagnostic Radiology, E. Wolfson Medical Center, Holon (Israel); Jones, P.W. [Department of Respiratory Medicine, St George' s Hospital Medical School, University of London (United Kingdom); Priel, I.E. [Department of Pulmonary Medicine, E. Wolfson Medical Center, Holon, Israel, Affiliated with the Sackler Faculty of Medicine, Tel-Aviv University (Israel)

    2007-02-15

    Aim: To evaluate the relationship between the severity of bronchiectatic diseases, as evident on high-resolution computed tomography (HRCT) and the patient's quality of life measured using the St George's Respiratory Questionnaire (SGRQ). Methods and materials: Forty-six patients (25 women, 21 men, mean age: 63 years) with bronchiectatic disease as evident on recent HRCT examinations were recruited. Each patient completed the SGRQ and underwent respiratory function tests. HRCT findings were blindly and independently scored by two radiologists, using the modified Bhalla scoring system. The relationships between HRCT scores, SGRQ scores and pulmonary function tests were evaluated. Results: The patients' total CT score did not correlate with the SGRQ scores. However, patients with more advanced disease on HRCT, significantly differed in their SGRQ scores from patients with milder bronchiectatic disease. A significant correlation was found between the CT scores for the middle and distal lung zones and the activity, impacts and total SGRQ scores. No correlation was found between CT scores and respiratory function test indices. However, a significant correlation was found between the SGRQ scores and most of the respiratory function test indices. Conclusion: A correlation between the severity of bronchiectatic disease as expressed in HRCT and the health-related quality of life exists in patients with a more severe bronchiectatic disease but not in patients with mild disease. Such correlation depends on the location of the bronchiectasis in the pulmonary tree.

  19. Radiographic and high resolution CT findings of non-specific interstitial pneumonia/fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Kondoh, Yasuhiro; Taniguchi, Hiroyuki; Nishiyama, Satoshi [Tosei General Hospital, Seto, Aichi (Japan); Yokoi, Toyoharu; Suzuki, Ryujiro; Noda, Yasunobu; Kato, Toshiyuki; Kaneko, Michie

    1999-01-01

    We evaluated the radiographic and high resolution CT findings in fifteen patients with biopsy proven nonspecific interstitial pneumonia. The most common radiographic findings in NSIP were bilateral infiltrates involving alveolar pattern, interstitial pattern, and mixed alveolar-interstitial pattern, which distributed mainly in the middle and lower lung zones. Loss of lung volumes were common. The predominant findings of linear and reticular opacities on HRCT were peribronchovascular interstitial thickening, parenchymal bands, intralobular interstitial thickening, and traction bronchiectasis. Honeycombing was not noted in any patient on initial CT scans. The predominant findings of increased lung opacity were mixed pattern of ground glass opacity and consolidation. Because these findings mimic those of idiopathic pulmonary fibrosis/usual interstitial pneumonia, distinction between NSIP and IPF/UIP seems to be difficult by radiographic and HRCT findings. The response to corticosteroid therapy was good. At follow up HRCT, the pulmonary abnormalities observed on initial scans had disappeared or were diminished in most cases. Intralobular interstitial thickening and traction bronchiectasis, that have been considered to be an indicator of irreversible fibrosis, occasionally disappeared after corticosteroid therapy. (author)

  20. National Electrical Manufacturers Association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner.

    Science.gov (United States)

    Szanda, Istvan; Mackewn, Jane; Patay, Gergely; Major, Peter; Sunassee, Kavitha; Mullen, Gregory E; Nemeth, Gabor; Haemisch, York; Blower, Philip J; Marsden, Paul K

    2011-11-01

    The NanoPET/CT represents the latest generation of commercial preclinical PET/CT systems. This article presents a performance evaluation of the PET component of the system according to the National Electrical Manufacturers Association (NEMA) NU-4 2008 standard. The NanoPET/CT consists of 12 lutetium yttrium orthosilicate:cerium modular detectors forming 1 ring, with 9.5-cm axial coverage and a 16-cm animal port. Each detector crystal is 1.12 × 1.12 × 13 mm, and 1 module contains 81 × 39 of these crystals. An optical light guide transmits the scintillation light to the flat-panel multianode position-sensitive photomultiplier tubes. Analog-to-digital converter cards and a field-programmable gate array-based data-collecting card provide the readout. Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated in accordance with the NEMA NU-4 standard. Energy and temporal resolution measurements and a mouse imaging study were performed in addition to the standard. Energy resolution was 19% at 511 keV. The spatial resolution, measured as full width at half maximum on single-slice rebinning/filtered backprojection-reconstructed images, approached 1 mm on the axis and remained below 2.5 mm in the central 5-cm transaxial region both in the axial center and at one-quarter field of view. The maximum absolute sensitivity for a point source at the center of the field of view was 7.7%. The maximum noise equivalent counting rates were 430 kcps at 36 MBq and 130 kcps at 27 MBq for the mouse- and rat-sized phantoms, respectively. The uniformity and recovery coefficients were measured with the image-quality phantom, giving good-quality images. In a mouse study with an (18)F-labeled thyroid-specific tracer, the 2 lobes of the thyroid were clearly distinguishable, despite the small size of this organ. The flexible readout system allowed experiments to be performed in an efficient manner, and the system remained stable throughout. The large number

  1. Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Jeremiah, E-mail: jeremiah.sanders@duke.edu [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Clinical Imaging Physics Group, Duke University, Durham, North Carolina 27710 (United States); Hurwitz, Lynne [Department of Radiology, Duke University, Durham, North Carolina 27710 (United States); Samei, Ehsan [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Clinical Imaging Physics Group, Duke University, Durham, North Carolina 27710 and Departments of Physics, Biomedical Engineering, Electrical and Computer Engineering, Duke University, Durham, North Carolina 27710 (United States)

    2016-10-15

    Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this

  2. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  3. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    International Nuclear Information System (INIS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-01-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance

  4. The application of high-resolution CT in the visualization of the vestibular aqueduct (Meniere's disease) and labyrinthine otospongiosis

    International Nuclear Information System (INIS)

    Zonneveld, F.W.; Groot, J.A.M. de; Huizing, E.H.; Damsma, H.; Waes, P.F.G.M. van

    1984-01-01

    Ever since the introduction of temporal bone imaging by means of high-resolution CT, it appears that the combination of high spatial resolution, high density resolution and the freedom of patient positioning for scanning of optimal otological planes may play a unique role in the diagnosis and follow-up of a number of otological disorder. Two examples are described here. The first is the possibility of determining whether the vestibular aqueduct in idiopathic Meniere's disease is obliterated or not, and if so, whether it is a bony or a fibrous obliteration. Although the results are preliminary, there are indications that all three cathegories occur and that the efficacy of drainage of the endolymphatic sac can be evaluated prior to surgery. The second example is the possibility of outlining and quantifying the bone mineral loss in cases of labyrinthine otospongiosis. Preliminary studies have outlined that there is a relationship between the degree of decalcification and the severity of sensorineural hearing loss. These examples show high-resolution, thin-section multiplanar CT to have great potential in the diagnosis and treatment of otological disorders. This will become evident as the techniques that were used here are worked out in more detail and become more widely known. (orig.)

  5. CT evaluation of abdominal trauma

    International Nuclear Information System (INIS)

    Huang Ruiting

    2004-01-01

    Objective: An evaluation of CT diagnosis of abdominal trauma. Methods: CT appearance of abdominal trauma was analyzed retrospectively in 95 cases. thirty-three patients were cured by operation, and the other 59 patients received conservative treatment. Fifty-one patients out of 59 were seen healed or improved by a follow up CT scan after the conservative treatment. Results: The study included: 31 cases of splenic contusion, accompanying with hemoperitoneum in 25 cases; 3 cases of hepatic laceration; 33 cases of liver and spleen compound trauma accompanying with hemoperitoneum; 18 cases of renal contusion, with subcapsular hemorrhage in 12 cases; 4 cases of midriff colic; 3 cases of mesentery breach; 3 cases of digestive tract perforation. Conclusion: CT is sensitive and precise in evaluating abdominal trauma, providing important information for treatment. (author)

  6. Characterizing, measuring, and utilizing the resolution of CT imagery for improved quantification of fine-scale features

    Energy Technology Data Exchange (ETDEWEB)

    Ketcham, Richard A., E-mail: ketcham@jsg.utexas.edu; Hildebrandt, Jordan

    2014-04-01

    Quantitative results extracted from computed tomographic (CT) data sets should be the same across resolutions and between different instruments and laboratory groups. Despite the proliferation of scanners and data processing methods and tools, and scientific studies utilizing them, relatively little emphasis has been given to ensuring that these results are comparable or reproducible. This issue is particularly pertinent when the features being imaged and measured are of the same order size as data voxels, as is often the case with fracture apertures, pore throats, and cell walls. We have created a tool that facilitates quantification of the spatial resolution of CT data via its point-spread function (PSF), in which the user draws a traverse across a sharp interface between two materials and a Gaussian PSF is fitted to the blurring across that interface. Geometric corrections account for voxel shape and the angle of the traverse to the interface, which does not need to be orthogonal. We use the tool to investigate a series of grid phantoms scanned at varying conditions and observe how the PSF varies within and between slices. The PSF increases with increasing radial distance within slices, and can increase tangentially with increasing radial distance in CT data sets acquired with relatively few projections. The PSF between CT slices is similar to that within slices when a 2-D detector is used, but is much sharper when the data are acquired one slice at a time with a collimated linear detector array. The capability described here can be used not only to calibrate processing algorithms that use deconvolution operations, but it can also help evaluate scans on a routine basis within and between CT research groups, and with respect to the features within the imagery that are being measured.

  7. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  8. Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

    Science.gov (United States)

    Rucher, Guillaume; Cameliere, Lucie; Fendri, Jihene; Abbas, Ahmed; Dupont, Kevin; Kamel, Said; Delcroix, Nicolas; Dupont, Axel; Berger, Ludovic; Manrique, Alain

    2018-04-30

    The purpose of this study was to assess the impact of positron emission tomography/X-ray computed tomography (PET/CT) acquisition and reconstruction parameters on the assessment of mineralization process in a mouse model of atherosclerosis. All experiments were performed on a dedicated preclinical PET/CT system. CT was evaluated using five acquisition configurations using both a tungsten wire phantom for in-plane resolution assessment and a bar pattern phantom for cross-plane resolution. Furthermore, the radiation dose of these acquisition configurations was calculated. The PET system was assessed using longitudinal line sources to determine the optimal reconstruction parameters by measuring central resolution and its coefficient of variation. An in vivo PET study was performed using uremic ApoE -/- , non-uremic ApoE -/- , and control mice to evaluate optimal PET reconstruction parameters for the detection of sodium [ 18 F]fluoride (Na[ 18 F]F) aortic uptake and for quantitative measurement of Na[ 18 F]F bone influx (Ki) with a Patlak analysis. For CT, the use of 1 × 1 and 2 × 2 binning detector mode increased both in-plane and cross-plane resolution. However, resolution improvement (163 to 62 μm for in-plane resolution) was associated with an important radiation dose increase (1.67 to 32.78 Gy). With PET, 3D-ordered subset expectation maximization (3D-OSEM) algorithm increased the central resolution compared to filtered back projection (1.42 ± 0.35 mm vs. 1.91 ± 0.08, p PET resolution for preclinical study (FWHM = 0.98 mm). These PET reconstruction parameters allowed the detection of Na[ 18 F]F aortic uptake in 3/14 ApoE -/- mice and demonstrated a decreased Ki in uremic ApoE -/- compared to non-uremic ApoE -/- and control mice (p PET. In addition, improving the CT resolution was associated with a dramatic radiation dose increase.

  9. Evaluation of radiation doses delivered in different chest CT protocols

    International Nuclear Information System (INIS)

    Gorycki, Tomasz; Lasek, Iwona; Kamiński, Kamil; Studniarek, Michał

    2014-01-01

    There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDI VOL ) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. CTDI VOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. Mean values of CTDI VOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDI VOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80–81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose

  10. High-resolution CT of lymphoid interstitial pneumonia

    International Nuclear Information System (INIS)

    Vilgrain, V.; Frija, J.; Yana, C.; Couderc, L.J.; David, M.; Clauvel, J.P.; Laval-Jeantet, M.

    1989-01-01

    Three patients with lymphoid interstitial pneumonia (two HIV 1+ patients with chronic lymphadenopathic syndromes and one with a not-characterized autoimmune disease) have been studied with high-resolution computed tomography (HR-CT). This technique reveals septal lines, small reticulonodular opacities, polyhedral micronodular opacities, 'ground-glass' opacities and a dense, subpleural, curved broken line in one patient. The lesions dominate in the bases of the lungs. They are not characteristic for lymphoid interstitial pneumonia. If a patient presents with a chronic lymphadenopathic syndrome, the diagnosis of an opportunistic infection should not be automatically made, since the syndrome can be caused by lymphoid interstitial pneumonia [fr

  11. Acute pulmonary injury: high-resolution CT and histopathological spectrum

    Science.gov (United States)

    Obadina, E T; Torrealba, J M

    2013-01-01

    Acute lung injury usually causes hypoxaemic respiratory failure and acute respiratory distress syndrome (ARDS). Although diffuse alveolar damage is the hallmark of ARDS, other histopathological patterns of injury, such as acute and fibrinoid organising pneumonia, can be associated with acute respiratory failure. Acute eosinophilic pneumonia can also cause acute hypoxaemic respiratory failure and mimic ARDS. This pictorial essay reviews the high-resolution CT findings of acute lung injury and the correlative histopathological findings. PMID:23659926

  12. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CTCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CTCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  13. Clinical evaluation of PET image reconstruction using a spatial resolution model

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Klausen, Thomas Levin; Loft, Annika

    2013-01-01

    PURPOSE: PET image resolution is variable across the measured field-of-view and described by the point spread function (PSF). When accounting for the PSF during PET image reconstruction image resolution is improved and partial volume effects are reduced. Here, we evaluate the effect of PSF......-based reconstruction on lesion quantification in routine clinical whole-body (WB) PET/CT imaging. MATERIALS AND METHODS: 41 oncology patients were referred for a WB-PET/CT examination (Biograph 40 TruePoint). Emission data were acquired at 2.5min/bed at 1hpi of 400 MBq [18F]-FDG. Attenuation-corrected PET images were...... reconstructed on 336×336-matrices using: (R1) standard AW-OSEM (4 iter, 8 subsets, 4mm Gaussian) and (R2) AW-OSEM with PSF (3 iter, 21 subsets, 2mm). Blinded and randomised reading of R1- and R2-PET images was performed. Individual lesions were located and counted independently on both sets of images...

  14. X-ray CT evaluation of pulmonary involvements of sarcoidosis

    International Nuclear Information System (INIS)

    Nishimura, Koichi; Izumi, Takateru; Kitaichi, Masanori

    1987-01-01

    We evaluated high resolution CT in 60 patients with histologically diagnosed pulmonary sarcoidosis and, also, studied the relationship between CT and findings in open lung biopsy specimens in 2 cases. The CT findings were as follows: (1) thickening of bronchial wall shadows (27 out of 60 cases, 45.0 %), (2) irregular enlargement of pulmonary vascular shadows (39 cases, 65.0 %), (3) small or large nodular shadows (24 cases, 40.0 %), (4) local volume loss (14 cases, 23.3 %), (5) slightly increased density of localized lung field areas (24 cases, 40.0 %), (6) pleural or subpleural involvement (27 cases, 45.0 %), (7) lymph node enlargement (59 cases, 98.3 %). X-ray CT in 7 patients revealed no evidence of lung field involvement in patients with histologicall confirmed epithelioid cell granuloma in transbronchial lung biopsy specimens. Lesions located within vessels or in the vascular wall, perivascular sheath or alveoli surrounding blood vessels might cause pulmonary vascular shadows to appear swollen on CT. In a comparative study, we found irregular dilatation of pulmonary vascular shadows corresponding to granulomas in the connective tissue sheath of blood vessels. Also, thickening of bronchial wall shadows corresponded to granulomas in and around the bronchial wall. From the point of histopathological view epithelioid cell granulomas in the bronchovascular sheath were most marked in sarcoidosis, and they apperaed on CT as an irregular enlargement of pulmonary vascular shadows and thickening of the bronchial wall. On the other hand, we reported that collapse of alveoli and fibrosis surrounding blood vessels could cause irregular enlargement of pulmonary vascular shadows on CT in idiopathic pulmonary fibrosis (IPF). Such shadows were seen on CT in both sarcoidosis and IPF but the mechanism of their appearance differed. (J.P.N.)

  15. SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Plautz, Tia E.; Johnson, R. P.; Sadrozinski, H. F.-W.; Zatserklyaniy, A. [University of California, Santa Cruz, Santa Cruz, CA (United States); Bashkirov, V.; Hurley, R. F.; Schulte, R. W. [Loma Linda University, Loma Linda, CA (United States); Piersimoni, P. [University of California, San Francisco, San Francisco, CA (United States); Giacometti, V. [University of Wollongong, Wollongong, NSW (Australia)

    2016-06-15

    Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

  16. Three-rooted premolar analyzed by high-resolution and cone beam CT.

    Science.gov (United States)

    Marca, Caroline; Dummer, Paul M H; Bryant, Susan; Vier-Pelisser, Fabiana Vieira; Só, Marcus Vinicius Reis; Fontanella, Vania; Dutra, Vinicius D'avila; de Figueiredo, José Antonio Poli

    2013-07-01

    The aim of this study was to analyze the variations in canal and root cross-sectional area in three-rooted maxillary premolars between high-resolution computed tomography (μCT) and cone beam computed tomography (CBCT). Sixteen extracted maxillary premolars with three distinct roots and fully formed apices were scanned using μCT and CBCT. Photoshop CS software was used to measure root and canal cross-sectional areas at the most cervical and the most apical points of each root third in images obtained using the two tomographic computed (CT) techniques, and at 30 root sections equidistant from both root ends using μCT images. Canal and root areas were compared between each method using the Student t test for paired samples and 95 % confidence intervals. Images using μCT were sharper than those obtained using CBCT. There were statistically significant differences in mean area measurements of roots and canals between the μCT and CBCT techniques (P < 0.05). Root and canal areas had similar variations in cross-sectional μCT images and became proportionally smaller in a cervical to apical direction as the cementodentinal junction was approached, from where the area then increased apically. Although variation was similar in the roots and canals under study, CBCT produced poorer image details than μCT. Although CBCT is a strong diagnosis tool, it still needs improvement to provide accuracy in details of the root canal system, especially in cases with anatomical variations, such as the three-rooted maxillary premolars.

  17. High-resolution imaging of pulmonary ventilation and perfusion with 68Ga-VQ respiratory gated (4-D) PET/CT

    International Nuclear Information System (INIS)

    Callahan, Jason; Hofman, Michael S.; Siva, Shankar; Kron, Tomas; Schneider, Michal E.; Binns, David; Eu, Peter; Hicks, Rodney J.

    2014-01-01

    Our group has previously reported on the use of 68 Ga-ventilation/perfusion (VQ) PET/CT scanning for the diagnosis of pulmonary embolism. We describe here the acquisition methodology for 68 Ga-VQ respiratory gated (4-D) PET/CT and the effects of respiratory motion on image coregistration in VQ scanning. A prospective study was performed in 15 patients with non-small-cell lung cancer. 4-D PET and 4-D CT images were acquired using an infrared marker on the patient's abdomen as a surrogate for breathing motion following inhalation of Galligas and intravenous administration of 68 Ga-macroaggregated albumin. Images were reconstructed with phase-matched attenuation correction. The lungs were contoured on CT and PET VQ images during free-breathing (FB) and at maximum inspiration (Insp) and expiration (Exp). The similarity between PET and CT volumes was measured using the Dice coefficient (DC) comparing the following groups; (1) FB-PET/CT, (2) InspPET/InspCT, (3) ExpPET/Exp CT, and (4) FB-PET/AveCT. A repeated measures one-way ANOVA with multiple comparison Tukey tests were performed to evaluate any difference between the groups. Diaphragmatic motion in the superior-inferior direction on the 4-D CT scan was also measured. 4-D VQ scanning was successful in all patients without additional acquisition time compared to the nongated technique. The highest volume overlap was between ExpPET and ExpCT and between FB-PET and AveCT with a DC of 0.82 and 0.80 for ventilation and perfusion, respectively. This was significantly better than the DC comparing the other groups (0.78-0.79, p 68 Ga-VQ 4-D PET/CT is feasible and the blurring caused by respiratory motion is well corrected with 4-D acquisition, which principally reduces artefact at the lung bases. The images with the highest spatial overlap were the combined expiration phase or FB PET and average CT. With higher resolution than SPECT/CT, the PET/CT technique has a broad range of potential clinical applications including

  18. Pulmonary tuberculosis with airspace consolidation vs mycoplasma pneumonia in adults: high-resolution CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Chull Hee; Choi, Gyo Chang; Park, Jai Soung; Hwang, Jung Hwa; Kim, Kyung Rak; Im, Han Haek; Kim, Dae Ho; Choi, Deuk Lin [Soonchunghyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-02-01

    To analyse and compare high-resolution CT findings of pulmonary tuberculosis with consolidation and mycoplasma pneumonia. Twenty patients with pulmonary tuberculosis [confirmed by sputum culture (n=9) and bronchoscopic biopsy (n=11)] and airspace consolidation on high-resolution CT and 17 patients with mycoplasma pneumonia, confirmed by serologic test, were included in this study. High-resolution CT findings were analyzed in terms of ground-glass opacities, distribution of consolidation, type of nodules, cavities, interlobular septal thickening, bronchial dilatations, bronchial wall thickening and pleural effusion. In patients with tuberculosis, average age was 33.5 years (range, 20-67); in those with mycoplasma pneumonia it was 32.5 years (range, 17-74). Segmental and subsegmental distributions were most common in both diseases; the preferred site of consolidation was different, however; for tuberculosis it was the upper lobes (13 cases, 65%; bilateral involvement, 7 cases); for mycoplasma pneumonia it was the lower lobes (11 cases, 64.7%). Non-segmental (diffuse and random) distribution of ground-glass opacities were seen in two patients(11.8%) with mycoplasma pneumonia. Centrilobular nodules, branching linear opacities and alveolar nodules were not different in both diseases, but there were nodules above 10mm in 14 cases of tuberculosis and in only one case of mycoplasma pneumonia. Tree-in-bud appearances were seen in five cases of tuberculosis. Cavities without air-fluid level were noted in ten cases of tuberculosis. Other interlobular septal thickening, bronchial wall thickening, bronchial dilatation and pleural effusion were not different in both diseases. There was considerable overlap between high resolution CT findings of tuberculosis with airspace consolidation and those of mycoplasma pneumonia. The location of consolidation, type of nodules, and the presence of tree-in-bud appearance and cavities help in the differentiation of the two diseases, however.

  19. Pulmonary tuberculosis with airspace consolidation vs mycoplasma pneumonia in adults: high-resolution CT findings

    International Nuclear Information System (INIS)

    Cha, Chull Hee; Choi, Gyo Chang; Park, Jai Soung; Hwang, Jung Hwa; Kim, Kyung Rak; Im, Han Haek; Kim, Dae Ho; Choi, Deuk Lin

    1997-01-01

    To analyse and compare high-resolution CT findings of pulmonary tuberculosis with consolidation and mycoplasma pneumonia. Twenty patients with pulmonary tuberculosis [confirmed by sputum culture (n=9) and bronchoscopic biopsy (n=11)] and airspace consolidation on high-resolution CT and 17 patients with mycoplasma pneumonia, confirmed by serologic test, were included in this study. High-resolution CT findings were analyzed in terms of ground-glass opacities, distribution of consolidation, type of nodules, cavities, interlobular septal thickening, bronchial dilatations, bronchial wall thickening and pleural effusion. In patients with tuberculosis, average age was 33.5 years (range, 20-67); in those with mycoplasma pneumonia it was 32.5 years (range, 17-74). Segmental and subsegmental distributions were most common in both diseases; the preferred site of consolidation was different, however; for tuberculosis it was the upper lobes (13 cases, 65%; bilateral involvement, 7 cases); for mycoplasma pneumonia it was the lower lobes (11 cases, 64.7%). Non-segmental (diffuse and random) distribution of ground-glass opacities were seen in two patients(11.8%) with mycoplasma pneumonia. Centrilobular nodules, branching linear opacities and alveolar nodules were not different in both diseases, but there were nodules above 10mm in 14 cases of tuberculosis and in only one case of mycoplasma pneumonia. Tree-in-bud appearances were seen in five cases of tuberculosis. Cavities without air-fluid level were noted in ten cases of tuberculosis. Other interlobular septal thickening, bronchial wall thickening, bronchial dilatation and pleural effusion were not different in both diseases. There was considerable overlap between high resolution CT findings of tuberculosis with airspace consolidation and those of mycoplasma pneumonia. The location of consolidation, type of nodules, and the presence of tree-in-bud appearance and cavities help in the differentiation of the two diseases, however

  20. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  1. Adaptive patch-based POCS approach for super resolution reconstruction of 4D-CT lung data

    International Nuclear Information System (INIS)

    Wang, Tingting; Cao, Lei; Yang, Wei; Feng, Qianjin; Chen, Wufan; Zhang, Yu

    2015-01-01

    Image enhancement of lung four-dimensional computed tomography (4D-CT) data is highly important because image resolution remains a crucial point in lung cancer radiotherapy. In this paper, we proposed a method for lung 4D-CT super resolution (SR) by using an adaptive-patch-based projection onto convex sets (POCS) approach, which is in contrast with the global POCS SR algorithm, to recover fine details with lesser artifacts in images. The main contribution of this patch-based approach is that the interfering local structure from other phases can be rejected by employing a similar patch adaptive selection strategy. The effectiveness of our approach is demonstrated through experiments on simulated images and real lung 4D-CT datasets. A comparison with previously published SR reconstruction methods highlights the favorable characteristics of the proposed method. (paper)

  2. Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ke; Chen, Guang-Hong, E-mail: gchen7@wisc.edu [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Garrett, John; Ge, Yongshuai [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States)

    2014-07-15

    Purpose: Statistical model based iterative reconstruction (MBIR) methods have been introduced to clinical CT systems and are being used in some clinical diagnostic applications. The purpose of this paper is to experimentally assess the unique spatial resolution characteristics of this nonlinear reconstruction method and identify its potential impact on the detectabilities and the associated radiation dose levels for specific imaging tasks. Methods: The thoracic section of a pediatric phantom was repeatedly scanned 50 or 100 times using a 64-slice clinical CT scanner at four different dose levels [CTDI{sub vol} =4, 8, 12, 16 (mGy)]. Both filtered backprojection (FBP) and MBIR (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for image reconstruction and results were compared with one another. Eight test objects in the phantom with contrast levels ranging from 13 to 1710 HU were used to assess spatial resolution. The axial spatial resolution was quantified with the point spread function (PSF), while the z resolution was quantified with the slice sensitivity profile. Both were measured locally on the test objects and in the image domain. The dependence of spatial resolution on contrast and dose levels was studied. The study also features a systematic investigation of the potential trade-off between spatial resolution and locally defined noise and their joint impact on the overall image quality, which was quantified by the image domain-based channelized Hotelling observer (CHO) detectability index d′. Results: (1) The axial spatial resolution of MBIR depends on both radiation dose level and image contrast level, whereas it is supposedly independent of these two factors in FBP. The axial spatial resolution of MBIR always improved with an increasing radiation dose level and/or contrast level. (2) The axial spatial resolution of MBIR became equivalent to that of FBP at some transitional contrast level, above which MBIR demonstrated superior spatial resolution than

  3. Stopping power accuracy and achievable spatial resolution of helium ion imaging using a prototype particle CT detector system

    Directory of Open Access Journals (Sweden)

    Volz Lennart

    2017-09-01

    Full Text Available A precise relative stopping power map of the patient is crucial for accurate particle therapy. Charged particle imaging determines the stopping power either tomographically – particle computed tomography (pCT – or by combining prior knowledge from particle radiography (pRad and x-ray CT. Generally, multiple Coulomb scattering limits the spatial resolution. Compared to protons, heavier particles scatter less due to their lower charge/mass ratio. A theoretical framework to predict the most likely trajectory of particles in matter was developed for light ions up to carbon and was found to be the most accurate for helium comparing for fixed initial velocity. To further investigate the potential of helium in particle imaging, helium computed tomography (HeCT and radiography (HeRad were studied at the Heidel-berg Ion-Beam Therapy Centre (HIT using a prototype pCT detector system registering individual particles, originally developed by the U.S. pCT collaboration. Several phantoms were investigated: modules of the Catphan QA phantom for analysis of spatial resolution and achievable stopping power accuracy, a paediatric head phantom (CIRS and a custom-made phantom comprised of animal meat enclosed in a 2 % agarose mixture representing human tissue. The pCT images were reconstructed applying the CARP iterative reconstruction algorithm. The MTF10% was investigated using a sharp edge gradient technique. HeRad provides a spatial resolution above that of protons (MTF1010%=6.07 lp/cm for HeRad versus MTF10%=3.35 lp/cm for proton radiography. For HeCT, the spatial resolution was limited by the number of projections acquired (90 projections for a full scan. The RSP accuracy for all inserts of the Catphan CTP404 module was found to be 2.5% or better and is subject to further optimisation. In conclusion, helium imaging appears to offer higher spatial resolution compared to proton imaging. In future studies, the advantage of helium imaging compared to other

  4. Pituitary gland and its stalk observed by high resolution CT

    International Nuclear Information System (INIS)

    Nakagawa, Yoshinobu; Fukami, Tsuneharu; Matsumoto, Keizo.

    1982-01-01

    It seemed to be important to recognize the CT findings of normal pituitary gland and the stalk for the acurate morphological diagnosis of pituitary microadenoma. In a consecutive series of normal 103 cases, the CT scans obtained by high resolution CT (CE-CT, Metrizamide CT) were analized and compared with 6 cases of microadenoma. The pituitary stalk demonstrated by the reconstructed coronal CT was examined and the inclination of the stalk was measured. The mean value of the inclination of pituitary stalk was 1.4 +- 1.7 0 in normal group and 9.3 +- 2.4 0 in microadenoma group. The form of the pituitary gland demonstrated by a reconstructed mid-saggital CT were classified into the following 3 types. Type I : The gland filling the whole pituitary fossa. Type II : The gland filled with small CSF space localized in the upper-anterior part in the pituitary fossa. Type III : The enlarged CSF space of more than half of the depth of pituitary fossa and the gland localized in the retro-lower part. As for the shape of pituitary gland, type I was revealed in 26 cases (7 cases in male and 19 cases in female), Type II was revealed in 31 cases (12 cases in male and 19 cases in female), Type III was revealed in 46 cases (25 cases in male and 21 cases in female). Type I was shown in female, especially in 10 years old young female. In 19 cases of 30 years to 40 years female, Type II was shown in 9 cases. In 44 male cases, Type I and Type II were shown in all ages. In the aged, Type III was shown in more than the other types. On the other hand, Type I was noted in 5 out of 6 cases of microadenoma group. (author)

  5. CT-diagnosis of temporal bone trauma

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Stuckmann, G.; Antonucci, F.; Schubiger, O.

    1986-02-01

    73 patients with 78 fractures of the temporal bone were examined by high-resolution computed tomography (CT). Analysis of the CT-findings disclosed 55 longitudinal, 12 transverse, 8 combined and 3 atypical fractures. For determination of the fracture type, axial sections usually proved sufficient. However, for precise topographic analysis of the course of the fracture additional coronal sections were necessary in most of the cases. In the radiologic evaluation of temporal bone fractures detection of associated. Complications is clinically important since these can be surgically corrected. In this series 20 lesions of the ossicular chain were demonstrated by the combined performance of axial and coronal sections and sagittal reformations. High resolution CT demonstrated a lesion of the facial nerve canal in 79% of a patient group with traumatic facial nerve palsy. The most frequent site of injury of the facial nerve canal was the region of the geniculate ganglion. With the use of metrizaminde-CT-cisternography the site of cerebrospinal fluid leakage was demonstrated in 7 of 9 patients with liquorrhea. It is concluded that high-resolution CT is the radiologic method of choice for both topographic evaluation of temporal bone fractures and detection and precise localization of fracture-complications. (orig.).

  6. Pneumonia in novel swine-origin influenza A (H1N1) virus infection: High-resolution CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Li Ping, E-mail: pinglee_2000@yahoo.com [Department of Radiology, The Second Affiliated Hospital of Harbin Medical University, 246 Xue Fu Road, Harbin 150086 (China); Su Dongju, E-mail: hyd_sdj@yahoo.com.cn [Department of Respiratory, The Second Affiliated Hospital of Harbin Medical University, 246 Xue Fu Road, Harbin 150086 (China); Zhang Jifeng, E-mail: zjf2005520@163.com [Department of Radiology, The Second Affiliated Hospital of Harbin Medical University, 246 Xue Fu Road, Harbin 150086 (China); Xia Xudong, E-mail: xiaxd888@163.com [Department of Radiology, The Second Affiliated Hospital of Harbin Medical University, 246 Xue Fu Road, Harbin 150086 (China); Sui Hong, E-mail: suisuihong@126.com [Department of Statistics, Harbin Medical University, 240 Xue Fu Road, Harbin 150086 (China); Zhao Donghui, E-mail: yhwoooooo@yahoo.com.cn [Centers for Disease Control and Prevention of Heilongjiang, 187 Xiang An Street, Harbin 150036 (China)

    2011-11-15

    Objective: The purpose of our study was to review the initial high-resolution CT (HRCT) findings in pneumonia patients with presumed/laboratory-confirmed novel swine-origin influenza A (H1N1) virus (S-OIV) infection and detect pneumonia earlier. Materials and methods: High-resolution CT (HRCT) findings of 106 patients with presumed/laboratory-confirmed novel S-OIV (H1N1) infection were reviewed. The 106 patients were divided into two groups according to the serious condition of the diseases. The pattern (consolidation, ground-glass, nodules, and reticulation), distribution, and extent of abnormality on the HRCT were evaluated in both groups. The dates of the onset of symptoms of the patients were recorded. Results: The predominant CT findings in the patients at presentation were unilateral or bilateral multifocal asymmetric ground-glass opacities alone (n = 29, 27.4%), with unilateral or bilateral consolidation (n = 50, 47.2%). The consolidation had peribronchovascular and subpleural predominance. The areas of consolidation were found mainly in the posterior, middle and lower regions of the lungs. Reticular opacities were found in 6 cases of the initial MDCT scan. The extent of disease was greater in group 1 patients requiring advanced mechanical ventilation, with diffuse involvement in 19 patients (63.3%) of group 1 patients, and only 15/76 (19.7%) of group 2 patients (p < 0.01, {chi}{sup 2} test). 20 cases (19%) of the 106 patients had small bilateral or unilateral pleural effusions. None had evidence of hilar or mediastinal lymph node enlargement on CT performed at admission or later. Conclusions: The most common radiographic and CT findings in patients with S-OIV infection are unilateral or bilateral ground-glass opacities with or without associated focal or multifocal areas of consolidation. On HRCT, the ground-glass opacities had a predominant peribronchovascular and subpleural distribution. CT plays an important role in the early recognition of severe S

  7. Pneumonia in novel swine-origin influenza A (H1N1) virus infection: High-resolution CT findings

    International Nuclear Information System (INIS)

    Li Ping; Su Dongju; Zhang Jifeng; Xia Xudong; Sui Hong; Zhao Donghui

    2011-01-01

    Objective: The purpose of our study was to review the initial high-resolution CT (HRCT) findings in pneumonia patients with presumed/laboratory-confirmed novel swine-origin influenza A (H1N1) virus (S-OIV) infection and detect pneumonia earlier. Materials and methods: High-resolution CT (HRCT) findings of 106 patients with presumed/laboratory-confirmed novel S-OIV (H1N1) infection were reviewed. The 106 patients were divided into two groups according to the serious condition of the diseases. The pattern (consolidation, ground-glass, nodules, and reticulation), distribution, and extent of abnormality on the HRCT were evaluated in both groups. The dates of the onset of symptoms of the patients were recorded. Results: The predominant CT findings in the patients at presentation were unilateral or bilateral multifocal asymmetric ground-glass opacities alone (n = 29, 27.4%), with unilateral or bilateral consolidation (n = 50, 47.2%). The consolidation had peribronchovascular and subpleural predominance. The areas of consolidation were found mainly in the posterior, middle and lower regions of the lungs. Reticular opacities were found in 6 cases of the initial MDCT scan. The extent of disease was greater in group 1 patients requiring advanced mechanical ventilation, with diffuse involvement in 19 patients (63.3%) of group 1 patients, and only 15/76 (19.7%) of group 2 patients (p 2 test). 20 cases (19%) of the 106 patients had small bilateral or unilateral pleural effusions. None had evidence of hilar or mediastinal lymph node enlargement on CT performed at admission or later. Conclusions: The most common radiographic and CT findings in patients with S-OIV infection are unilateral or bilateral ground-glass opacities with or without associated focal or multifocal areas of consolidation. On HRCT, the ground-glass opacities had a predominant peribronchovascular and subpleural distribution. CT plays an important role in the early recognition of severe S-OIV (H1N1).

  8. Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Bridoux, Alexandre; Hutt, Antoine; Faivre, Jean-Baptiste; Pagniez, Julien; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), 59037 Lille Cedex (France); Flohr, Thomas [Siemens Healthcare, Department of Research and Development in CT, Forchheim (Germany); Duhamel, Alain [Universite de Lille, Department of Biostatistics, Lille (France)

    2015-11-15

    Dual-source CT allows scanning of the chest with high pitch and high temporal resolution, which can improve the detection of proximal coronary arteries in infants and young children when scanned without general anesthesia, sedation or beta-blockade. To compare coronary artery visibility between higher and standard temporal resolution. We analyzed CT images in 93 children who underwent a standard chest CT angiographic examination with reconstruction of images with a temporal resolution of 75 ms (group 1) and 140 ms (group 2). The percentage of detected coronary segments was higher in group 1 than in group 2 when considering all segments (group 1: 27%; group 2: 24%; P = 0.0004) and proximal segments (group 1: 37%; group 2: 32%; P = 0.0006). In both groups, the highest rates of detection were observed for the left main coronary artery (S1) (group 1: 65%; group 2: 58%) and proximal left anterior descending coronary artery (S2) (group 1: 43%; group 2: 42%). Higher rates of detection were seen in group 1 for the left main coronary artery (P = 0.03), proximal right coronary artery (P = 0.01), proximal segments of the left coronary artery (P = 0.02) and proximal segments of the left and right coronary arteries (P = 0.0006). Higher temporal resolution improved the visibility of proximal coronary arteries in pediatric chest CT. (orig.)

  9. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  10. High-Resolution C-Arm CT and Metal Artifact Reduction Software: A Novel Imaging Modality for Analyzing Aneurysms Treated with Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y

    2016-02-01

    Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.

  11. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    International Nuclear Information System (INIS)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul

    2001-01-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  12. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  13. MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dillenseger, Jean-Philippe; Goetz, Christian [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Matern, Jean-Francois [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Gros, Catherine-Isabelle; Bornert, Fabien [Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Universite de Strasbourg, Faculte de Chirurgie Dentaire, Strasbourg (France); Le Minor, Jean-Marie [Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Universite de Strasbourg, Institut d' Anatomie Normale, Strasbourg (France); Constantinesco, Andre [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Choquet, Philippe [Hopitaux Universitaires de Strasbourg, Imagerie Preclinique-UF6237, Pole d' imagerie, Strasbourg (France); Universite de Strasbourg, Icube, equipe MMB, CNRS, Strasbourg (France); Universite de Strasbourg, Federation de Medecine Translationnelle de Strasbourg, Faculte de Medecine, Strasbourg (France); Hopital de Hautepierre, Imagerie Preclinique, Biophysique et Medecine Nucleaire, Strasbourg Cedex (France)

    2014-09-24

    Our aim was to conduct a quantitative and qualitative evaluation of high-resolution skull-bone imaging for dentistry and otolaryngology using different architectures of recent X-ray computed tomography systems. Three multi-slice computed tomography (MSCT) systems and one Cone-beam computed tomography (CBCT) system were used in this study. All apparatuses were tested with installed acquisition modes and proprietary reconstruction software enabling high-resolution bone imaging. Quantitative analyses were performed with small fields of view with the preclinical vmCT phantom, which permits to measure spatial resolution, geometrical accuracy, linearity and homogeneity. Ten operators performed visual qualitative analyses on the vmCT phantom images, and on dry human skull images. Quantitative analysis showed no significant differences between protocols in terms of linearity and geometric accuracy. All MSCT systems present a better homogeneity than the CBCT. Both quantitative and visual analyses demonstrate that CBCT acquisitions are not better than the collimated helical MSCT mode. Our results demonstrate that current high-resolution MSCT protocols could exceed the performance of a previous generation CBCT system for spatial resolution and image homogeneity. (orig.)

  14. MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging

    International Nuclear Information System (INIS)

    Dillenseger, Jean-Philippe; Goetz, Christian; Matern, Jean-Francois; Gros, Catherine-Isabelle; Bornert, Fabien; Le Minor, Jean-Marie; Constantinesco, Andre; Choquet, Philippe

    2015-01-01

    Our aim was to conduct a quantitative and qualitative evaluation of high-resolution skull-bone imaging for dentistry and otolaryngology using different architectures of recent X-ray computed tomography systems. Three multi-slice computed tomography (MSCT) systems and one Cone-beam computed tomography (CBCT) system were used in this study. All apparatuses were tested with installed acquisition modes and proprietary reconstruction software enabling high-resolution bone imaging. Quantitative analyses were performed with small fields of view with the preclinical vmCT phantom, which permits to measure spatial resolution, geometrical accuracy, linearity and homogeneity. Ten operators performed visual qualitative analyses on the vmCT phantom images, and on dry human skull images. Quantitative analysis showed no significant differences between protocols in terms of linearity and geometric accuracy. All MSCT systems present a better homogeneity than the CBCT. Both quantitative and visual analyses demonstrate that CBCT acquisitions are not better than the collimated helical MSCT mode. Our results demonstrate that current high-resolution MSCT protocols could exceed the performance of a previous generation CBCT system for spatial resolution and image homogeneity. (orig.)

  15. Comparison of quantitative myocardial perfusion imaging CT to fluorescent microsphere-based flow from high-resolution cryo-images

    Science.gov (United States)

    Eck, Brendan L.; Fahmi, Rachid; Levi, Jacob; Fares, Anas; Wu, Hao; Li, Yuemeng; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    Myocardial perfusion imaging using CT (MPI-CT) has the potential to provide quantitative measures of myocardial blood flow (MBF) which can aid the diagnosis of coronary artery disease. We evaluated the quantitative accuracy of MPI-CT in a porcine model of balloon-induced LAD coronary artery ischemia guided by fractional flow reserve (FFR). We quantified MBF at baseline (FFR=1.0) and under moderate ischemia (FFR=0.7) using MPI-CT and compared to fluorescent microsphere-based MBF from high-resolution cryo-images. Dynamic, contrast-enhanced CT images were obtained using a spectral detector CT (Philips Healthcare). Projection-based mono-energetic images were reconstructed and processed to obtain MBF. Three MBF quantification approaches were evaluated: singular value decomposition (SVD) with fixed Tikhonov regularization (ThSVD), SVD with regularization determined by the L-Curve criterion (LSVD), and Johnson-Wilson parameter estimation (JW). The three approaches over-estimated MBF compared to cryo-images. JW produced the most accurate MBF, with average error 33.3+/-19.2mL/min/100g, whereas LSVD and ThSVD had greater over-estimation, 59.5+/-28.3mL/min/100g and 78.3+/-25.6 mL/min/100g, respectively. Relative blood flow as assessed by a flow ratio of LAD-to-remote myocardium was strongly correlated between JW and cryo-imaging, with R2=0.97, compared to R2=0.88 and 0.78 for LSVD and ThSVD, respectively. We assessed tissue impulse response functions (IRFs) from each approach for sources of error. While JW was constrained to physiologic solutions, both LSVD and ThSVD produced IRFs with non-physiologic properties due to noise. The L-curve provided noise-adaptive regularization but did not eliminate non-physiologic IRF properties or optimize for MBF accuracy. These findings suggest that model-based MPI-CT approaches may be more appropriate for quantitative MBF estimation and that cryo-imaging can support the development of MPI-CT by providing spatial distributions of MBF.

  16. CT-based attenuation correction and resolution compensation for I-123 IMP brain SPECT normal database: a multicenter phantom study.

    Science.gov (United States)

    Inui, Yoshitaka; Ichihara, Takashi; Uno, Masaki; Ishiguro, Masanobu; Ito, Kengo; Kato, Katsuhiko; Sakuma, Hajime; Okazawa, Hidehiko; Toyama, Hiroshi

    2018-03-19

    Statistical image analysis of brain SPECT images has improved diagnostic accuracy for brain disorders. However, the results of statistical analysis vary depending on the institution even when they use a common normal database (NDB), due to different intrinsic spatial resolutions or correction methods. The present study aimed to evaluate the correction of spatial resolution differences between equipment and examine the differences in skull bone attenuation to construct a common NDB for use in multicenter settings. The proposed acquisition and processing protocols were those routinely used at each participating center with additional triple energy window (TEW) scatter correction (SC) and computed tomography (CT) based attenuation correction (CTAC). A multicenter phantom study was conducted on six imaging systems in five centers, with either single photon emission computed tomography (SPECT) or SPECT/CT, and two brain phantoms. The gray/white matter I-123 activity ratio in the brain phantoms was 4, and they were enclosed in either an artificial adult male skull, 1300 Hounsfield units (HU), a female skull, 850 HU, or an acrylic cover. The cut-off frequency of the Butterworth filters was adjusted so that the spatial resolution was unified to a 17.9 mm full width at half maximum (FWHM), that of the lowest resolution system. The gray-to-white matter count ratios were measured from SPECT images and compared with the actual activity ratio. In addition, mean, standard deviation and coefficient of variation images were calculated after normalization and anatomical standardization to evaluate the variability of the NDB. The gray-to-white matter count ratio error without SC and attenuation correction (AC) was significantly larger for higher bone densities (p correction. The proposed protocol showed potential for constructing an appropriate common NDB from SPECT images with SC, AC and spatial resolution compensation.

  17. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  18. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D)

    International Nuclear Information System (INIS)

    Rock, C.; Kotsianos, D.; Linsenmaier, U.; Fischer, T.

    2002-01-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [de

  19. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. No significant differences in quantitative measures of image quality were found between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6 pitch 3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch = 3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom

  20. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    International Nuclear Information System (INIS)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H.

    2009-01-01

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6≤pitch≤3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  1. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H. [Siemens Healthcare, Computed Tomography, 91301 Forchheim, Germany and Department of Diagnostic Radiology, Eberhard-Karls-Universitaet, 72076 Tuebingen (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Siemens Healthcare, Computed Tomography, 91301 Forchheim (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2009-12-15

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  2. Studies on evaluation of staging of cancer of the uterine cervix by means of CT

    Energy Technology Data Exchange (ETDEWEB)

    Kakizaki, D

    1987-03-01

    The present study was undertaken to evaluate the stage classification (FIGO) by using CT in 50 cases with cancer of the uterine cervix in which the final stage had been diagnosed. An accurate diagnosis was obtained in 6 of 14 Ib cases, 14 of 21 IIa cases, 5 of 6 IIb cases, 2 of 3 IIIa cases, 3 of 3 IIIb cases and 3 of 3 IVa cases, for a total of 33 of 50 (66 %). The diagnostic rate for Ib and IIa staging was 57 %, while that for IIb or more was 87 %, but the accuracy rate in IIIb and IVa was 100 %. As the equipment, a high resolutional GE 9800 CT using a special technique was employed. Employing special pretreatment for the patient, it became possible to accurately grasp the pelvic condition of the patients. CT evaluation was related to the extent of the cervical cancer and the presence of infiltration into the vaginal wall. According to a 4-stage classification of the CT image, the extent of infiltration to surrounding parametrium and the bladder was determined. As a result, the sensitivity for evaluating invasion into surrounding tissue raised 92 %, and it showed 100 % for cases with adhesion or invasion of the bladder. Therefore, CT can an extremely effective method to determine the clinical staging of cancer of the uterine cervix.

  3. Utility of F-18 FDG PET/CT on the evaluation of primary bone lymphoma.

    Science.gov (United States)

    Wang, Li-Juan; Wu, Hu-Bing; Wang, Meng; Han, Yan-Jiang; Li, Hong-Sheng; Zhou, Wen-Lan; Wang, Quan-Shi

    2015-11-01

    Primary bone lymphoma (PBL) is a rare type of malignant lymphoma. Few data have been reported regarding the utility of F-18 FDG PET/CT in this disease. The aim of this study was to assess the role of F-18 FDG PET/CT in the diagnosis and therapeutic effect evaluation of PBL. A total of 19 consecutive patients with PBL were enrolled. Whole-body PET/CT scan was performed for all patients. The diagnosis of PBL was established by histopathology and immunohistochemistry. F-18 FDG PET/CT was positive in 94.7% (18/19) of patients. Uptake of FDG in lesions was intense with SUVmax of 15.14 ± 11.82. Multiple involved lesions were found in 47.4% (9/19) patients, while 52.6% presented with a single involved lesion. Based on the lesions, PET detected 98.9% (87/88) lesions. Among them, 71.6% (63/88) lesions were found to be located in axial skeleton and 28.4% (25/88) in the extremity skeleton. FDG PET/CT also found the lesions infiltrate to the surrounding soft tissue in 84.2% (16/19) patients. On the syn-modality CT, the bone destruction was noted in 43.2% (38/88) of the lesions, of which 50.0% lesions presented as slight change in bone density and 50.0% as severe change. The diagnostic sensitivity of PET was much higher than that of CT (98.9% vs. 43.2%, P=0.000). PET/CT was performed for evaluation of treatment response in 13 patients. In 12 patients with complete response(CR), PET/CT found the 25 lesions were F-18 FDG fully resoluted after treatment, however, bone destruction was still presented in 72.0% (18/25) lesions. The present study suggests that F-18 FDG PET/CT was a sensitive imaging modality for diagnosis and treatment response evaluation of PBL. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. High resolution CT in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Spina, Juan C.; Curros, Marisela L.; Gomez, M.; Gonzalez, A.; Chacon, Carolina; Guerendiain, G.

    2000-01-01

    Objectives: To establish the particular advantages of High Resolution CT (HRCT) for the diagnosis of pulmonary sarcoidosis. Material and Methods: A series of fourteen patients, (4 men and 10 women; mean age 44,5 years) with thoracic sarcoidosis. All patients were studied using HRCT and diagnosis was confirmed for each case. Confidence intervals were obtained for different disease manifestations. Results: The most common findings were: lymph node enlargement (n=14 patients), pulmonary nodules (n=13), thickening of septa (n=6), peribronquial vascular thickening (n=5) pulmonary pseudo mass (n=5) and signs of fibrosis (n=4). The stage most commonly observed was stage II. It is worth noting that no cases of pleural effusion or cavitations of pulmonary lesions were observed. Conclusions: In this series, confidence interval overlapping for lymph node enlargement, single pulmonary nodules and septum thickening, allows to infer that their presence in a young adult, with few clinical symptoms, forces to rule out first the possibility of sarcoidosis. (author)

  5. Primary staging of laryngeal and hypopharyngeal cancer: CT, MR imaging and dual-energy CT

    International Nuclear Information System (INIS)

    Kuno, Hirofumi; Onaya, Hiroaki; Fujii, Satoshi; Ojiri, Hiroya; Otani, Katharina; Satake, Mitsuo

    2014-01-01

    Laryngeal and hypopharyngeal cancer, in particular T4a disease associated with cartilage invasion and extralaryngeal spread, needs to be evaluated accurately because treatment can impact heavily on a patient's quality of life. Reliable imaging tools are therefore indispensible. CT offers high spatial and temporal resolution and remains the preferred imaging modality. Although cartilage invasion can be diagnosed with acceptable accuracy by applying defined criteria for combinations of erosion, lysis and transmural extralaryngeal spread, iodine-enhanced tumors and non-ossified cartilage are sometimes difficult to distinguish. MR offers high contrast resolution for images without motion artifacts, although inflammatory changes in cartilage sometimes resemble cartilage invasion. With dual-energy CT, combined iodine overlay images and weighted average images can be used for evaluation of cartilage invasion, since iodine enhancement is evident in tumor tissue but not in cartilage. Extralaryngeal spread can be evaluated from CT, MR or dual-energy CT images and the routes of tumor spread into the extralaryngeal soft tissue must be considered; (1) via the thyrohyoid membrane along the superior laryngeal neurovascular bundle, (2) via the inferior pharyngeal constrictor muscle, and (3) via the cricothyroid membrane. Radiologists need to understand the advantages and limitations of each imaging modality for staging of laryngeal and hypopharyngeal cancer

  6. Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

    Science.gov (United States)

    Meyer, Mathias; Haubenreisser, Holger; Raupach, Rainer; Schmidt, Bernhard; Lietzmann, Florian; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Schad, Lothar R; Schoenberg, Stefan O; Henzler, Thomas

    2015-01-01

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm(2) removes the necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50% • A smaller focal spot of 0.2 mm (2) significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear.

  7. Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?

    Science.gov (United States)

    Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R

    2014-01-01

    Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951

  8. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  9. Radical pancreatectomy: postoperative evaluation by CT

    Energy Technology Data Exchange (ETDEWEB)

    Heiken, J.P.; Balfe, D.M.; Picus, D.; Scharp, D.W.

    1984-10-01

    Twenty-four patients who had undergone radical pancreatic resection were evaluated by CT one week to 11 years after surgery. Eighteen patients had had the Whipple procedure; six had had total pancreatectomy. The region between the aorta and superior mesenteric artery, previously occupied by the uncinate process of the pancreas, is an important area to evaluate for tumor recurrence because periampullary tumors tend to metastasize to the lymph nodes in this region. Tumor recurrence here is readily detectable by CT since radical pancreatectomy leaves this area area free of soft tissue attenuation material. CT demonstrated postoperative complications or tumor recurrence in 16 of the 24 patients and was 100% accurate in patients who had follow-up.

  10. Radical pancreatectomy: postoperative evaluation by CT

    International Nuclear Information System (INIS)

    Heiken, J.P.; Balfe, D.M.; Picus, D.; Scharp, D.W.

    1984-01-01

    Twenty-four patients who had undergone radical pancreatic resection were evaluated by CT one week to 11 years after surgery. Eighteen patients had had the Whipple procedure; six had had total pancreatectomy. The region between the aorta and superior mesenteric artery, previously occupied by the uncinate process of the pancreas, is an important area to evaluate for tumor recurrence because periampullary tumors tend to metastasize to the lymph nodes in this region. Tumor recurrence here is readily detectable by CT since radical pancreatectomy leaves this area area free of soft tissue attenuation material. CT demonstrated postoperative complications or tumor recurrence in 16 of the 24 patients and was 100% accurate in patients who had follow-up

  11. Development of high-resolution x-ray CT system using parallel beam geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Akio, E-mail: akio.yoneyama.bu@hitachi.com; Baba, Rika [Central Research Laboratory, Hitachi Ltd., Hatoyama, Saitama (Japan); Hyodo, Kazuyuki [Institute of Materials Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan); Takeda, Tohoru [School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa (Japan); Nakano, Haruhisa; Maki, Koutaro [Department of Orthodontics, School of Dentistry Showa University, Ota-ku, Tokyo (Japan); Sumitani, Kazushi; Hirai, Yasuharu [Kyushu Synchrotron Light Research Center, Tosu, Saga (Japan)

    2016-01-28

    For fine three-dimensional observations of large biomedical and organic material samples, we developed a high-resolution X-ray CT system. The system consists of a sample positioner, a 5-μm scintillator, microscopy lenses, and a water-cooled sCMOS detector. Parallel beam geometry was adopted to attain a field of view of a few mm square. A fine three-dimensional image of birch branch was obtained using a 9-keV X-ray at BL16XU of SPring-8 in Japan. The spatial resolution estimated from the line profile of a sectional image was about 3 μm.

  12. Complicated pleural tuberculosis in children: CT evaluation

    International Nuclear Information System (INIS)

    Moon, W.K.; Kim, W.S.; Kim, I.O.; Im, J.G.; Kim, J.H.; Yeon, K.M.; Han, M.C.

    1999-01-01

    Purpose. To describe the CT features of complicated pleural tuberculosis in children and to define the use of CT in children with pleural tuberculosis. Materials and methods. The CT findings in 11 children with complicated pleural tuberculosis were retrospectively analysed. CT was performed to evaluate persistent pleural thickening (n = 6) or a mass-like lesion (n = 5) detected on plain radiographs. Chest radiographs and medical records were reviewed to determine whether additional information provided by CT had altered clinical management. Results. On CT, more than one location was involved in five patients (45 %) and in two patients (18 %) the entire pleural spaces were involved. Pleural thickening was seen in all 11 patients and enhancement after administration of contrast medium occurred in ten patients (91 %). Low-density fluid collections were seen in nine patients (82 %) and in two, CT revealed fluid collections within calcified pleural lesions. In five patients with mass-like lesions on plain radiographs, CT showed a low-density pleural mass with peripheral enhancement in four and a calcified pleural mass with fluid collection in one. CT demonstrated parenchymal abnormalities on the same side as pleural lesions in all 11 patients and hilar or mediastinal adenopathy in four. Four patients (36 %) underwent surgery because of fluid within a calcified fibrothorax (n = 3) and chest wall tuberculosis (n = 1) that were seen only on CT. Conclusions. The CT features of complicated pleural tuberculosis in children were pleural thickening, enhancement and fluid collection with associated parenchymal abnormalities and lymphadenopathy. In the evaluation of children with pleural tuberculosis, CT can be useful for demonstrating fluid within a calcified fibrothorax or chest wall involvement, which usually requires surgical intervention. (orig.)

  13. Accurate heterogeneous dose calculation for lung cancer patients without high‐resolution CT densities

    Science.gov (United States)

    Li, Jonathan G.; Liu, Chihray; Olivier, Kenneth R.; Dempsey, James F.

    2009-01-01

    The aim of this study was to investigate the relative accuracy of megavoltage photon‐beam dose calculations employing either five bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full‐resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full‐resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cm3, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 DVHs of the planning target volume (PTV), agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. These required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high‐resolution CT studies for accurate treatment planning. PACS number: 87.53.Tf

  14. Tomography high Resolution CT findings of nontuberculous mycobacterial pulmonary disease: Comparison between the first treatment and the re treatment group

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Soon Hyuk; Cho, Bum Sang; Jeon, Min Hee; Kim, Eun Young; Kang, Min Ho; Yi, Kyung Sik; Lee, Seung Young; Kim, Sung Jin; Lee, Ki Man [Chungbuk National Univ., Cheongju, (Korea, Republic of)

    2012-06-15

    To analyze and compare the thin section CT findings of first and re treatment nontuberculous mycobacterial (NTM) pulmonary disease. Between January 2005 and April 2010, 121 patients with positive sputum culture for NTM were recruited. We included only 32 patients underwent high resolution chest CT and were confirmed by American Thoracic Society criteria NTM pulmonary infection (first treatment 15, re treatment 17 patients). CT images of 32 patients were reviewed retrospectively. We evaluated the frequency and laterality of the followings; nodule, increased density, bronchial change, parenchymal change. The significantly frequent CT findings of the re treatment NTM group were well defined nodules (retreatment 82.4%, first treatment 33.3%, p = 0.00), consolidations (retreatment 88.2%, first treatment 53.3%, p = 0.03), bronchial changes (bronchiectasis; retreatment 100%, first treatment 66.6%, p = 0.01, bronchial narrowing; retreatment 23.5%, first treatment 0%, p = 0.04 and mucoid impaction; retreatment-58.8%, first treatment-20.0%, p = 0.03) and atelectasis with bronchiectasis (retreatment-88.2%, first treatment 26.7%, p = 0.00). However, most of the evaluated thin section CT findings, such as centrilobular and ill defined nodules, lobular, segmental and subpleural consolidations, ground glass attenuation, bronchial wall thickening, cavities, pleural lesions, fibrotic band, emphysema and laterality of lesions, have not shown significant differences between first treatment and the re treatment group. Thin section CT findings of well defined nodules, consolidations, bronchial changes (bronchiectasis, bronchial narrowing and mucoid impaction) and atelectasis with bronchiectasis are highly suggestive of re treatment NTM pulmonary disease.

  15. Evaluation of Marfan syndrome: MR imaging versus CT

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fishman, E.K.; Pyeritz, R.E.; Gott, V.L.; Zerhouni, E.A.

    1986-01-01

    Twenty-five patients with Marfan, syndrome underwent both CT and MR imaging. MR imaging were interpreted in blinded fashion and then compared with CT scans MR imaging was found to be equivalent to CT in the detection of aortic, dural, and hip abnormalities in patients not operated on. MR imaging was superior to CT in the evaluation of postoperative patients because the artifact produced by Bjork-Shirley or St. Jude valves precludes adequate evaluation of the aortic root on CT while producing only a small inferior field distortion (a ''pseudo-ventricular septal defect'') on MR imaging. The absence of radiation exposure is another major advantage of MR imaging in this relatively young population requiring serial studies. The authors conclude that MR imaging is the modality of choice for the evaluation and follow-up of patients with Marfan syndrome and offers an appropriate means of screening their kindred

  16. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

    Science.gov (United States)

    Doerfler, A; Gölitz, P; Engelhorn, T; Kloska, S; Struffert, T

    2015-10-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range, flat-panel detector technology has meanwhile got widely accepted in the neuroradiological community. Especially flat-panel detector computed tomography (FD-CT) using rotational C-arm mounted flat-panel detector technology is capable of volumetric imaging with a high spatial resolution. By providing CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize hemorrhage and may thus improve complication management without the need of patient transfer. As "Angiographic CT" FD-CT may be helpful during many diagnostic and neurointerventional procedures and for noninvasive monitoring and follow-up. In addition, spinal interventions and high-resolution imaging of the temporal bone might also benefit from FD-CT. Finally, using novel dynamic perfusion and angiographic protocols, FD-CT may provide functional information on brain perfusion and vasculature with the potential to replace standard imaging in selected acute stroke patients.

  17. High resolution CT of the lungs in acute disseminated tuberculosis and a pediatric radiology perspectice of the term 'miliary'

    International Nuclear Information System (INIS)

    Jamieson, D.H.; Cremin, B.J.

    1993-01-01

    High resolution CT (HRCT) of the lungs in six children with acute disseminated tuberculosis was evaluated. There was a wide variation in the HRCT appearances. This covered differences in size, distribution and concentration of nodular opacities. Coalescence of nodules and the presence of intestitial thickening was variable. The recognition of acute disseminated tuberculosis is important for diagnosis and has prognostic implications. The use of the term 'acute disseminated tuberculosis' rather than 'miliary tuberculosis' is advocated. (orig.)

  18. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  19. Improved spatial resolution and lower-dose pediatric CT imaging: a feasibility study to evaluate narrowing the X-ray photon energy spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Benz, Mark G. [Safer Pediatric Imaging and Engineering Horizons International, Lincoln, VT (United States); Benz, Matthew W. [Southboro Medical Group, Southboro, MA (United States); Birnbaum, Steven B. [Dartmouth Hitchcock Clinic Manchester, Department of Radiology, Manchester, NH (United States); Chason, Eric; Sheldon, Brian W. [Brown University, Division of Engineering, Materials Science and Engineering Program, Providence, RI (United States); McGuire, Dale [R and D Manager, C and G Technologies Inc., Jeffersonville, IN (United States)

    2014-08-15

    This feasibility study has shown that improved spatial resolution and reduced radiation dose can be achieved in pediatric CT by narrowing the X-ray photon energy spectrum. This is done by placing a hafnium filter between the X-ray generator and a pediatric abdominal phantom. A CT system manufactured in 1999 that was in the process of being remanufactured was used as the platform for this study. This system had the advantage of easy access to the X-ray generator for modifications to change the X-ray photon energy spectrum; it also had the disadvantage of not employing the latest post-imaging noise reduction iterative reconstruction technology. Because we observed improvements after changing the X-ray photon energy spectrum, we recommend a future study combining this change with an optimized iterative reconstruction noise reduction technique. (orig.)

  20. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  1. CT of maxillofacial injury

    International Nuclear Information System (INIS)

    DeLaPaz, R.; Brant-Zawadzki, M.; Rowe, L.D.

    1986-01-01

    Computed tomography has the ability to evaluate maxillofacial trauma quickly. The well-known contrast resolution capabilities of CT play a role in the usefulness of this modality. However, it is the image manipulation capability which is of singular advantage in these cases. The spatial resolution of computed tomography has matched that of conventional pluridirectional tomography in current generation equipment. Since a set of axial CT sections can be obtained with automatic table incrementation within 12 minutes, the information content per time of study ratio is improved over that of conventional tomography, despite the fact that image reformation requires extra time on the part of the radiologist. Radiation savings are significantly in favor of computed tomography as well. In the authors' experience, computed tomography is the primary diagnostic imaging modality used in the evaluation of complex facial trauma, after routine screening films are obtained

  2. Atypical adenomatous hyperplasia of the lung: correlation between high-resolution CT findings and histopathologic features

    International Nuclear Information System (INIS)

    Kawakami, S.; Takashima, S.; Li, F.; Yang, Z.G.; Maruyama, Y.; Hasegawa, M.; Wang, J.C.; Sone, S.; Honda, T.

    2001-01-01

    We describe herein the CT features of atypical adenomatous hyperplasia (AAH) of the lung and its histopathological characteristics. Among 17,919 individuals screened for lung cancer by CT scanning, ten AAH nodules were detected in nine asymptomatic subjects. On high-resolution CT, the lesions measured from 6 x 6 mm to 15 x 17 mm and their CT number ranged from -500 to -760 HU. The AAHs appeared as round nodules with smooth and distinct borders and showed a ground-glass opacity. Plain chest radiographs failed to identify all lesions. Histopathologically, AAH lesions showed atypical epithelial cell proliferation along slightly thickened alveolar septa. Whereas it is often easy to differentiate these nodules from inflammatory and benign lung lesions, histopathological examination remains at present the only method to differentiate AAH from lung cancers. (orig.)

  3. Atypical adenomatous hyperplasia of the lung: correlation between high-resolution CT findings and histopathologic features

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, S.; Takashima, S.; Li, F.; Yang, Z.G.; Maruyama, Y.; Hasegawa, M.; Wang, J.C. [Dept. of Radiology, Shinshu University School of Medicine, Matsumoto (Japan); Sone, S. [Dept. of Radiology, Shinshu University School of Medicine, Matsumoto (Japan); Azumi General Hospital, Ikeda, Nagano (Japan); Honda, T. [Dept. of Laboratory Medicine, Shinshu University School of Medicine, Matsumoto (Japan)

    2001-05-01

    We describe herein the CT features of atypical adenomatous hyperplasia (AAH) of the lung and its histopathological characteristics. Among 17,919 individuals screened for lung cancer by CT scanning, ten AAH nodules were detected in nine asymptomatic subjects. On high-resolution CT, the lesions measured from 6 x 6 mm to 15 x 17 mm and their CT number ranged from -500 to -760 HU. The AAHs appeared as round nodules with smooth and distinct borders and showed a ground-glass opacity. Plain chest radiographs failed to identify all lesions. Histopathologically, AAH lesions showed atypical epithelial cell proliferation along slightly thickened alveolar septa. Whereas it is often easy to differentiate these nodules from inflammatory and benign lung lesions, histopathological examination remains at present the only method to differentiate AAH from lung cancers. (orig.)

  4. Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Yeung, Ivan W. T. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2016-01-15

    Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the

  5. Quality control of some CT scanners in Khartoum state

    International Nuclear Information System (INIS)

    Yousif, Ali Mohammed Ali

    2013-06-01

    This study conduced with the aim to evaluate the performance of three CT scanner in Khartoum-Sudan through extensive quality control measurements. Image quality was assessed using a CATPHAN 412 CT image quality phantom. Image quality parameters evaluated were: CT image noise, uniformity, CT number linearity, Low Contrast Resolution, High Contrast Resolution, measurements were performed in accordance with guidelines set out by the Institute of physical science and engineering in medicine (IPEM 91). Image quality parameters tested were within the apoplectic limit specified in the relevant CT guidelines. Measured slice thickness ranged between 9.66-10.5 mm for large slice and 5.25-5.88 for medium slice. The correlation coefficient (R) between the measured and the reference CT number was better than 0.99 for all CT scanners. High resolution for large slice was 7 L P/ cm and 8 L P/ cm for small slice. Low contrast resolution with 1.0% nominal level ranged between 2-3 mm diameter of disc for large slice and 4-7 mm diameter disc for small slice. The measured noise ranged between 1.4-3.4 HU for large slice and 2.92-4.08 HU for small slice. Uniformity ranged between 3.08 to 2.075 HU for large slice and 3.22 to 1.4 HU for small slice thickness. The results indicate that routine maintenance, service and calibration, as well as the frequent quality control of CT scanners play a key rote in achieving the best performance of the system. Since computed tomography (CT) contributes the most to the collective dose compared to other radiological examinations, it is a necessity for quality control and quality assurance programs to be established in each radiology department.(Author)

  6. Development and performance evaluation of an experimental fine pitch detector multislice CT scanner.

    Science.gov (United States)

    Imai, Yasuhiro; Nukui, Masatake; Ishihara, Yotaro; Fujishige, Takashi; Ogata, Kentaro; Moritake, Masahiro; Kurochi, Haruo; Ogata, Tsuyoshi; Yahata, Mitsuru; Tang, Xiangyang

    2009-04-01

    The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction) x 32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI(vol) of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

  7. SU-E-J-35: Clinical Performance Evaluation of a Phase II Proton CT Scanner

    International Nuclear Information System (INIS)

    Mandapaka, A; Ghebremedhin, A; Farley, D; Giacometti, V; Vence, N; Bashkirov, V; Patyal, B; Schulte, R; Plautz, T; Zatserklyaniy, A; Johnson, R; Sadrozinski, H

    2014-01-01

    Purpose: To develop the methodology to evaluate the clinical performance of a Phase II Proton CT scanner Methods: Range errors on the order of 3%-5% constitute a major uncertainty in current charged particle treatment planning based on Hounsfield Unit (HU)-relative stopping power (RSP) calibration curves. Within our proton CT collaboration, we previously developed and built a Phase I proton CT scanner that provided a sensitive area of 9 cm (axial) × 18 cm (in-plane). This scanner served to get initial experience with this new treatment planning tool and to incorporate lessons learned into the next generation design. A Phase II scanner was recently completed and is now undergoing initial performance testing. It will increase the proton acquisition rate and provide a larger detection area of 9 cm x 36 cm. We are now designing a comprehensive evaluation program to test the image quality, imaging dose, and range uncertainty associated with this scanner. The testing will be performed along the lines of AAPM TG 66. Results: In our discussion of the evaluation protocol we identified the following priorities. The image quality of proton CT images, in particular spatial resolution and low-density contrast discrimination, will be evaluated with the Catphan600 phantom. Initial testing showed that the Catphan uniformity phantom did not provide sufficient uniformity; it was thus replaced by a cylindrical water phantom. The imaging dose will be tested with a Catphan dose module, and compared to a typical cone beam CT dose for comparable image quality. Lastly, we developed a dedicated dosimetry range phantom based on the CIRS pediatric head phantom HN715. Conclusion: A formal evaluation of proton CT as a new tool for proton treatment planning is an important task. The availability of the new Phase II proton CT scanner will allow us to perform this task. This research is supported by the National Institute of Biomedical Imaging and Bioengineering of the NIH under award number R01

  8. Serial high resolution CT in non-specific interstitial pneumonia: prognostic value of the initial pattern

    Energy Technology Data Exchange (ETDEWEB)

    Screaton, N.J. [Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)]. E-mail: nicholas.screaton@papworth.nhs.uk; Hiorns, M.P. [Department of Radiology, Great Ormond Street Hospital, London (United Kingdom); Lee, K.S. [Samsung Medical Centre, Seoul (Korea); Franquet, T. [Hospital de Saint Pau, Universidad Autonoma de Barcelona, Barcelona (Spain); Johkoh, T. [Department of Medical Physics and Radiology, Osaka University Graduate School of Medicine, Osaka (Japan); Fujimoto, K. [Department of Radiology, Kurume University School of Medicine, Kurume (Japan); Ichikado, K. [First Department of Internal Medicine, Kumamoto University School of Medicine, Kumamoto (Japan); Colby, T.V. [Department of Laboratory Medicine/Pathology, Mayo Clinic Scottsdale, AZ (United States); Mueller, N.L. [Department of Radiology, Vancouver General Hospital, Vancouver (Canada)

    2005-01-01

    AIM: To assess the relationship between initial CT pattern and serial changes in CT findings and pulmonary function tests (PFTs) in patients with non-specific interstitial pneumonia (NSIP). MATERIALS AND METHODS: Serial high resolution (HR) CTs and PFTs were retrospectively analyzed in 38 cases of histologically proven NSIP, including 4 with cellular NSIP, 13 with mixed cellular and fibrotic NSIP, and 21 with fibrotic NSIP. The presence and extent of various CT findings were assessed. A fibrosis index (defined as the ratio of the extent of a reticular/honeycomb pattern to the overall extent of abnormal parenchyma) was derived. RESULTS: The predominant CT pattern was reticular/honeycomb in 27 (84%) cases and ground-glass/consolidation in 6 (16%) cases. Between scans, mean disease extent reduced by 5.2%. Disease extent reduced by >10% in 13 (34%) and increased by >10% in 6 (16%) patients. Histopathological subtype of NSIP did not correlate with individual CT pattern, predominant pattern, fibrosis index or serial change in disease extent on CT or PFTs. Response on follow-up CT was associated with fibrosis index, predominant pattern and extent of consolidation on initial CT. CONCLUSION: In NSIP disease, progression on CT correlates with the predominant CT pattern, fibrosis index, and extent of consolidation but not with histopathological subtype. An inflammatory (ground-glass/consolidation) predominant pattern is associated with better outcome in terms of disease extent on HRCT.

  9. Quantitative Assessment of Degenerative Cartilage and Subchondral Bony Lesions in a Preserved Cadaveric Knee: Propagation-Based Phase-Contrast CT Versus Conventional MRI and CT.

    Science.gov (United States)

    Geith, Tobias; Brun, Emmanuel; Mittone, Alberto; Gasilov, Sergei; Weber, Loriane; Adam-Neumair, Silvia; Bravin, Alberto; Reiser, Maximilian; Coan, Paola; Horng, Annie

    2018-04-09

    The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm 2 FOV, and a pixel size of 46 × 46 μm 2 . PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.

  10. High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications

    International Nuclear Information System (INIS)

    Mehndiratta, Amit; Rabinov, James D.; Grasruck, Michael; Liao, Eric C.; Crandell, David; Gupta, Rajiv

    2015-01-01

    This paper evaluates a prototype flat-panel volume CT (fpVCT) for dynamic in vivo imaging in a variety of neurovascular and lower limb applications. Dynamic CTA was performed on 12 patients (neuro = 8, lower limb = 4) using an fpVCT with 120 kVp, 50 mA, rotation time varying from 8 to 19 s, and field of view of 25 x 25 x 18 cm 3 . Four-dimensional data sets (i.e. 3D images over time) were reconstructed and reviewed. Dynamic CTA demonstrated sufficient spatio-temporal resolution to elucidate first-pass and recirculation dynamics of contrast bolus through neurovasclar pathologies and phasic blood flow though lower-limb vasculature and grafts. The high spatial resolution of fpVCT resulted in reduced partial volume and metal beam-hardening artefacts. This facilitated assessment of vascular lumen in the presence of calcified plaque and evaluation of fractures, especially in the presence of fixation hardware. Evaluation of arteriovenous malformation using dynamic fpVCT angiography was of limited utility. Dynamic CTA using fpVCT can visualize time-varying phenomena in neuro and lower limb vascular applications and has sufficient diagnostic imaging quality to evaluate a number of pathologies affecting these regions. (orig.)

  11. Renal stone characterization using high resolution imaging mode on a photon counting detector CT system

    Science.gov (United States)

    Ferrero, A.; Gutjahr, R.; Henning, A.; Kappler, S.; Halaweish, A.; Abdurakhimova, D.; Peterson, Z.; Montoya, J.; Leng, S.; McCollough, C.

    2017-03-01

    In addition to the standard-resolution (SR) acquisition mode, a high-resolution (HR) mode is available on a research photon-counting-detector (PCD) whole-body CT system. In the HR mode each detector consists of a 2x2 array of 0.225 mm x 0.225 mm subpixel elements. This is in contrast to the SR mode that consists of a 4x4 array of the same subelements, and results in 0.25 mm isotropic resolution at iso-center for the HR mode. In this study, we quantified ex vivo the capabilities of the HR mode to characterize renal stones in terms of morphology and mineral composition. Forty pure stones - 10 uric acid (UA), 10 cystine (CYS), 10 calcium oxalate monohydrate (COM) and 10 apatite (APA) - and 14 mixed stones were placed in a 20 cm water phantom and scanned in HR mode, at radiation dose matched to that of routine dual-energy stone exams. Data from micro CT provided a reference for the quantification of morphology and mineral composition of the mixed stones. The area under the ROC curve was 1.0 for discriminating UA from CYS, 0.89 for CYS vs COM and 0.84 for COM vs APA. The root mean square error (RMSE) of the percent UA in mixed stones was 11.0% with a medium-sharp kernel and 15.6% with the sharpest kernel. The HR showed qualitatively accurate characterization of stone morphology relative to micro CT.

  12. Lung Ultrasonography in Patients With Idiopathic Pulmonary Fibrosis: Evaluation of a Simplified Protocol With High-Resolution Computed Tomographic Correlation.

    Science.gov (United States)

    Vassalou, Evangelia E; Raissaki, Maria; Magkanas, Eleftherios; Antoniou, Katerina M; Karantanas, Apostolos H

    2018-03-01

    To compare a simplified ultrasonographic (US) protocol in 2 patient positions with the same-positioned comprehensive US assessments and high-resolution computed tomographic (CT) findings in patients with idiopathic pulmonary fibrosis. Twenty-five consecutive patients with idiopathic pulmonary fibrosis were prospectively enrolled and examined in 2 sessions. During session 1, patients were examined with a US protocol including 56 lung intercostal spaces in supine/sitting (supine/sitting comprehensive protocol) and lateral decubitus (decubitus comprehensive protocol) positions. During session 2, patients were evaluated with a 16-intercostal space US protocol in sitting (sitting simplified protocol) and left/right decubitus (decubitus simplified protocol) positions. The 16 intercostal spaces were chosen according to the prevalence of idiopathic pulmonary fibrosis-related changes on high-resolution CT. The sum of B-lines counted in each intercostal space formed the US scores for all 4 US protocols: supine/sitting and decubitus comprehensive US scores and sitting and decubitus simplified US scores. High-resolution CT-related Warrick scores (J Rheumatol 1991; 18:1520-1528) were compared to US scores. The duration of each protocol was recorded. A significant correlation was found between all US scores and Warrick scores and between simplified and corresponding comprehensive scores (P idiopathic pulmonary fibrosis. The 16-intercostal space simplified protocol in the lateral decubitus position correlated better with high-resolution CT findings and was less time-consuming compared to the sitting position. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  14. Role of CT in Congenital Heart Disease.

    Science.gov (United States)

    Rajiah, Prabhakar; Saboo, Sachin S; Abbara, Suhny

    2017-01-01

    Congenital heart diseases (CHD) are being increasingly encountered in cardiac imaging due to improved outcomes from surgical and interventional techniques. Imaging plays an important role in the evaluation of CHD, both prior to and after surgeries and interventions. Computed tomography (CT) has several advantages in the evaluation of these disorders, particularly its high spatial resolution, multi-planar reconstruction capabilities at sub-millimeter isotropic resolution, good temporal resolution, wide field of view, and rapid turnaround time, which minimizes the need for sedation and anesthesia in young children or children with disabilities. With modern scanners, images can be acquired as fast as within one heartbeat. Although there is a risk of ionizing radiation, the radiation dose can be minimized by using several dose reduction strategies. There is a risk of contrast nephrotoxicity in patients with renal dysfunction. In this article, we will review the role of CT in the evaluation of several congenital heart diseases, both in children and adults.

  15. Evaluation of CT findings for diagnosis of pleural effusions

    International Nuclear Information System (INIS)

    Arenas-Jimenez, J.; Alonso-Charterina, S.; Fernandez-Latorre, F.; Gil-Sanchez, S.; Sanchez-Paya, J.; Lloret-Llorens, M.

    2000-01-01

    Computed tomography studies are usually used to assess patients with pleural effusions, and radiologists should be aware of the significance of different CT findings for the diagnosis of the effusion. The purpose of this study was to evaluate CT findings for etiological diagnosis of pleural effusions. Contrast-enhanced CT of the chest of 211 patients with pleural effusion of definite diagnosis were evaluated. The CT images were evaluated for the presence and extent of pleural effusion, thickening or nodules, extrapleural fat and other changes in the mediastinum or lung. The CT scans were read by two independent observers and correlation between them was evaluated. Comparison of CT findings between benign and malignant effusions, between exudates and transudates, and between empyemas and the other parapneumonic effusions were carried out. Kappa values for most CT findings were >0.85. Loculation, pleural thickening, pleural nodules, and extrapleural fat of increased density were only present in exudative effusions. Multiple pleural nodules and nodular pleural thickening were the only pleural findings limited to malignant pleural effusions. The signs were also more frequently seen in empyemas than in other parapneumonic effusions. Computed tomography findings can help to distinguish between transudates and exudates. Although there is some overlap between benign and malignant pleural effusions, pleural nodules and nodular pleural thickening were present almost exclusively in the latter. Although differences between CT findings of empyemas and the other parapneumonic effusions exist, there is no finding which can definitely differentiate between them. (orig.)

  16. Initial evaluation of commercial optical CT-based 3D gel dosimeter

    International Nuclear Information System (INIS)

    Islam, K.T.S.; Dempsey, James F.; Ranade, Manisha K.; Maryanski, Marek J.; Low, Daniel A.

    2003-01-01

    We evaluated the OCTOPUS-ONE trade mark sign research laser CT scanner developed and manufactured by MGS Research, Inc. (Madison, CT). The scanner is designed for imaging 3D optical density distributions in BANG registered gels. The scanner operates in a translate-rotate configuration with a single scanning laser beam. The rotating cylindrical gel phantom is immersed in a refractive index matching solution and positioned at the center of a square tank made of plastic and glass. A stationary polarized He-Ne laser beam (633 nm) is reflected from a mirror moving parallel to the tank wall and scans the gel. Another mirror moves synchronously along the opposite side of the tank and collects the transmitted light and sends it to a single stationary silicon photodetector. A filtered backprojection algorithm is used to reconstruct projection data in a plane. The laser-mirrors-detector assembly is mounted on a horizontal platform that moves vertically for slice selection. We have tested the mechanical and optical setup, projection centering on the axis of rotation, linearity, and spatial resolution. We found the optical detector to respond linearly to transmitted light from control samples. The spatial resolution of the scanner was determined by employing a split field resolution technique. We obtained the horizontal and vertical full widths at half maxima of the laser beam intensity profiles as 0.6 and 0.8 mm, respectively. Dose calibration tests of the gel were performed using a nine-field (2x2 cm 2 each) dose pattern irradiated at different dose levels. Finally, we compared gel-derived 2D planar dose distribution against radiochromic film measured dose distribution for both the nine-field and a uniform 5x5 cm 2 field of 6 MV x rays. Very similar dose distributions were observed in gel and radiochromic film except in regions of steep dose gradient and highest dose. A dose normalization of 15.6% was required between the two dosimeters due to differences in overall

  17. Asbestosis and other pulmonary fibrosis in asbestos-exposed workers: high-resolution CT features with pathological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki [Dokkyo Medical University, Department of Radiology, Mibu, Tochigi (Japan); Kishimoto, Takumi [Okayama Rosai Hospital, Asbestos Research Center, Okayama (Japan); Ashizawa, Kazuto [Nagasaki University Graduate School of Biomedical Sciences, Department of Clinical Oncology, Nagasaki (Japan); Kato, Katsuya [Kawasaki Medical School, Department of Diagnostic Radiology 2, Okayama (Japan); Okamoto, Kenzo [Hokkaido Chuo Hospital, Department of Pathology, Iwamizawa, Hokkaido (Japan); Honma, Koichi [Dokkyo Medical University, Department of Pathology, Mibu, Tochigi (Japan); Hayashi, Seiji [National Hospital Organization Kinki-Chuo Chest Medical Center, Osaka (Japan); Akira, Masanori [National Hospital Organization Kinki-Chuo Chest Medical Center, Department of Radiology, Osaka (Japan)

    2016-05-15

    The purpose was to identify distinguishing CT features of pathologically diagnosed asbestosis, and correlate diagnostic confidence with asbestos body burden. Thirty-three workers (mean age at CT: 73 years) with clinical diagnoses of asbestosis, who were autopsied (n = 30) or underwent lobectomy (n = 3), were collected. Two radiologists independently scored high-resolution CT images for various CT findings and the likelihood of asbestosis was scored. Two pathologists reviewed the pathology specimens and scored the confidence of their diagnoses. Asbestos body count was correlated with CT and pathology scores. Pathologically, 15 cases were diagnosed as asbestosis and 18 cases with various lung fibroses other than asbestosis. On CT, only the score of the subpleural curvilinear lines was significantly higher in asbestosis (p = 0.03). Accuracy of CT diagnosis of asbestosis with a high confidence ranged from 0.73 to 0.79. Asbestos body count positively correlated with CT likelihood of asbestosis (r = 0.503, p = 0.003), and with the confidence level of pathological diagnosis (r = 0.637, p < 0.001). Subpleural curvilinear lines were the only clue for the diagnosis of asbestosis. However, this was complicated by other lung fibrosis, especially at low asbestos body burden. (orig.)

  18. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  19. Direct microCT imaging of non-mineralized connective tissues at high resolution.

    Science.gov (United States)

    Naveh, Gili R S; Brumfeld, Vlad; Dean, Mason; Shahar, Ron; Weiner, Steve

    2014-01-01

    The 3D imaging of soft tissues in their native state is challenging, especially when high resolution is required. An X-ray-based microCT is, to date, the best choice for high resolution 3D imaging of soft tissues. However, since X-ray attenuation of soft tissues is very low, contrasting enhancement using different staining materials is needed. The staining procedure, which also usually involves tissue fixation, causes unwanted and to some extent unknown tissue alterations. Here, we demonstrate that a method that enables 3D imaging of soft tissues without fixing and staining using an X-ray-based bench-top microCT can be applied to a variety of different tissues. With the sample mounted in a custom-made loading device inside a humidity chamber, we obtained soft tissue contrast and generated 3D images of fresh, soft tissues with a resolution of 1 micron voxel size. We identified three critical conditions which make it possible to image soft tissues: humidified environment, mechanical stabilization of the sample and phase enhancement. We demonstrate the capability of the technique using different specimens: an intervertebral disc, the non-mineralized growth plate, stingray tessellated radials (calcified cartilage) and the collagenous network of the periodontal ligament. Since the scanned specimen is fresh an interesting advantage of this technique is the ability to scan a specimen under load and track the changes of the different structures. This method offers a unique opportunity for obtaining valuable insights into 3D structure-function relationships of soft tissues.

  20. High-resolution imaging of pulmonary ventilation and perfusion with {sup 68}Ga-VQ respiratory gated (4-D) PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Jason [Centre for Molecular Imaging, Peter MacCallum Cancer Centre, East Melbourne, VIC (Australia); Hofman, Michael S. [The University of Melbourne, Department of Medicine, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia); Siva, Shankar [The University of Melbourne, Peter MacCallum Cancer Centre, Department of Radiation Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); Kron, Tomas [The University of Melbourne, Sir Peter MacCallum Department of Oncology, East Melbourne, VIC (Australia); The University of Melbourne, Peter MacCallum Cancer Centre, Department of Physical Sciences, East Melbourne, VIC (Australia); Schneider, Michal E. [Monash University, Department of Medical Imaging and Radiation Science, Clayton, VIC (Australia); Binns, David; Eu, Peter [Peter MacCallum Cancer Centre, Centre for Cancer Imaging, East Melbourne, VIC (Australia); Hicks, Rodney J. [The University of Melbourne, Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne, VIC (Australia)

    2014-02-15

    PET/CT is feasible and the blurring caused by respiratory motion is well corrected with 4-D acquisition, which principally reduces artefact at the lung bases. The images with the highest spatial overlap were the combined expiration phase or FB PET and average CT. With higher resolution than SPECT/CT, the PET/CT technique has a broad range of potential clinical applications including diagnostic algorithms for patients with suspected pulmonary embolism, preoperative evaluation of regional lung function and improving assessment or understanding of pulmonary physiology in the vast range of pulmonary diseases. (orig.)

  1. High resolution CT for localization of early hilar lung carcinoma

    International Nuclear Information System (INIS)

    Minami, Yuko; Ishikawa, Shigemi; Saida, Yukihisa; Kajitani, Motomasa; Yamamoto, Tatsuo; Sato, Yukio; Onizuka, Masataka; Sakakibara, Yuzuru; Noguchi, Masayuki

    2002-01-01

    The purpose of this study was to analyse the usefulness of high resolution CT (HRCT) for the diagnosis and localization of roentgenographically occult lung cancer. HRCT was performed prospectively on chest X-ray negative patients with bloody sputum or suspicious or positive cells on sputum cytology between 1998 and 2000. After the HRCT scan, white light bronchoscopy and autofluorescence bronchoscopy were performed. HRCT depicted 19 hilar bronchial lesions in 13 cases out of 19 patients, of which 9 lesions were confirmed by white light broncoscope. Of 8 hilar squamous cell carcinomas diagnosed in this study, 7 lesions (87.5%) were depicted by HRCT. One CT-negative case (12.5%) was an in situ carcinoma in left B 1+2 . Four out of 20 lesions which showed bronchoscopic abnormality, could not be depicted by HRCT. HRCT could prospectively detect 80% of the bronchoscopic abnormalities and 87.5% of the hilar squamous cell carcinomas of the tracheobronchial lesions of the lung. Therefore, HRCT can be an effective supplemental means for screening for hilar squamous cell carcinoma. (author)

  2. Exogenous lipoid pneumonia: high-resolution CT findings

    International Nuclear Information System (INIS)

    Lee, J.S.; Song, K.S.; Lim, T.H.; Im, J.G.; Seo, J.B.

    1999-01-01

    The aim of this study was to assess high-resolution computed tomography (HRCT) findings of exogenous lipoid pneumonia. High-resolution computed tomography was obtained in 25 patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). Diagnosis was based on biopsy (n = 9), bronchoalveolar lavage (n = 8), or sputum cytology and clinical findings (n = 8). The clinical history of taking squalene was confirmed in all patients. The CT findings were classified into three patterns: diffuse ground-glass opacity, consolidation, and interstitial abnormalities. Distribution of the abnormalities, duration of taking squalene, predisposing factors for aspiration, and route of administration were analyzed. Ten patients showed diffuse ground-glass opacity pattern. Seven of 10 patients had predisposing conditions such as unconsciousness, pharyngeal dysmotility, or motor disturbances, and 6 patients had a recent history of taking large amount of squalene through nasal route. Seven patients who had consolidation pattern had a history of taking squalene for several months and did not have any predisposing factor. All of the 5 patients who had a pattern of interstitial abnormalities had a history of taking squalene longer than 1 year and showed segmental distribution of interstitial thickening with interposing ground-glass opacities. Three patients simultaneously had two different patterns at different lobes of the lung. The HRCT findings of lipoid pneumonia are ground-glass opacities, consolidation, and interstitial abnormalities. These HRCT findings with appropriate inquiries could be useful for diagnosis of exogeneous lipoid pneumonia. (orig.)

  3. Fully automatic segmentation of femurs with medullary canal definition in high and in low resolution CT scans.

    Science.gov (United States)

    Almeida, Diogo F; Ruben, Rui B; Folgado, João; Fernandes, Paulo R; Audenaert, Emmanuel; Verhegghe, Benedict; De Beule, Matthieu

    2016-12-01

    Femur segmentation can be an important tool in orthopedic surgical planning. However, in order to overcome the need of an experienced user with extensive knowledge on the techniques, segmentation should be fully automatic. In this paper a new fully automatic femur segmentation method for CT images is presented. This method is also able to define automatically the medullary canal and performs well even in low resolution CT scans. Fully automatic femoral segmentation was performed adapting a template mesh of the femoral volume to medical images. In order to achieve this, an adaptation of the active shape model (ASM) technique based on the statistical shape model (SSM) and local appearance model (LAM) of the femur with a novel initialization method was used, to drive the template mesh deformation in order to fit the in-image femoral shape in a time effective approach. With the proposed method a 98% convergence rate was achieved. For high resolution CT images group the average error is less than 1mm. For the low resolution image group the results are also accurate and the average error is less than 1.5mm. The proposed segmentation pipeline is accurate, robust and completely user free. The method is robust to patient orientation, image artifacts and poorly defined edges. The results excelled even in CT images with a significant slice thickness, i.e., above 5mm. Medullary canal segmentation increases the geometric information that can be used in orthopedic surgical planning or in finite element analysis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Evaluation of CT in the investigation of patellofemoral malalignment

    International Nuclear Information System (INIS)

    Zhang Quan; Huang Huangyuan; Xia Jun; Chen Wenjun

    1999-01-01

    Objective: To evaluate CT in investigating patellofemoral malalignment. Methods: CT was used to evaluate 32 patients (50 knees) with persistent patellofemoral pain and 15 asymptomatic volunteers (20 knees). Multiple mid-patellar images were obtained at 30 degree flexion. Results: Compared to controls, the patients had marked malalignment including three distinct patterns. 11 knees had lateral patellae based on high congruence angles (CA). 8 knees had tilted patellae with lower lateral patellofemoral angles (LPFA). 10 knees had both high CA and lower LPFA indicating both lateral and tilted patella. Conclusions: CT may be the optimal imaging method of evaluating the patellofemoral joint. An awareness of different patterns of malalignment is a significant advantage of CT when planning selective surgical realignment for these patients

  5. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  6. Visual quantification of diffuse emphysema with Sakal's method and high-resolution chest CT

    International Nuclear Information System (INIS)

    Feuerstein, I.M.; McElvaney, N.G.; Simon, T.R.; Hubbard, R.C.; Crystal, R.G.

    1990-01-01

    This paper determines the accuracy and efficacy of visual quantitation for a diffuse form of pulmonary emphysema with high-resolution CT (HRCT). Twenty- five adults patients with symptomatic emphysema due to α-antitrypsin deficiency prospectively underwent HRCT with 1.5-mm sections, a high-spatial-resolution algorithm, and targeted reconstruction. Photography was performed with narrow lung windows to accentuate diffuse emphysema. Emphysema was then scored with use of a modification of Sakai's extent and severity scoring method. The scans were all scored by the same blinded observer. Pulmonary function testing (PFT), including diffusing capacity measurement, was performed in all patients. Results were statistically correlated with the use of regression analysis

  7. High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications

    Energy Technology Data Exchange (ETDEWEB)

    Mehndiratta, Amit [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States); University of Oxford, Institute of Biomedical Engineering and Keble College, Oxford (United Kingdom); Indian Institute of Technology Delhi and All India Institute of Medical Science, Centre for Biomedical Engineering, New Delhi (India); Rabinov, James D. [Massachusetts General Hospital, Interventional Neuroradiology, Harvard Medical School, Boston, MA (United States); Grasruck, Michael [Siemens Medical Solutions, Forchheim (Germany); Liao, Eric C. [Massachusetts General Hospital, Department of Plastic and Reconstructive Surgery and Center for Regenerative Medicine, Harvard Medical School, Boston, MA (United States); Crandell, David [Spaulding Rehabilitation Hospital, Department of Physical Medicine and Rehabilitation, Harvard Medical School, Charlestown, MA (United States); Gupta, Rajiv [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2015-07-15

    This paper evaluates a prototype flat-panel volume CT (fpVCT) for dynamic in vivo imaging in a variety of neurovascular and lower limb applications. Dynamic CTA was performed on 12 patients (neuro = 8, lower limb = 4) using an fpVCT with 120 kVp, 50 mA, rotation time varying from 8 to 19 s, and field of view of 25 x 25 x 18 cm{sup 3}. Four-dimensional data sets (i.e. 3D images over time) were reconstructed and reviewed. Dynamic CTA demonstrated sufficient spatio-temporal resolution to elucidate first-pass and recirculation dynamics of contrast bolus through neurovasclar pathologies and phasic blood flow though lower-limb vasculature and grafts. The high spatial resolution of fpVCT resulted in reduced partial volume and metal beam-hardening artefacts. This facilitated assessment of vascular lumen in the presence of calcified plaque and evaluation of fractures, especially in the presence of fixation hardware. Evaluation of arteriovenous malformation using dynamic fpVCT angiography was of limited utility. Dynamic CTA using fpVCT can visualize time-varying phenomena in neuro and lower limb vascular applications and has sufficient diagnostic imaging quality to evaluate a number of pathologies affecting these regions. (orig.)

  8. Accuracy of high-resolution CT in distinguishing between Pneumocystis carinii pneumonia and non-Pneumocystis carinii pneumonia in AIDS patients

    International Nuclear Information System (INIS)

    Hidalgo, A.; Mauleon, S.; Andreu, J.; Caceres, J.; Falco, V.; Crespo, M.; Ribera, E.; Pahissa, A.

    2003-01-01

    The aim of this study was to assess the value of high-resolution CT in distinguishing between Pneumocystis carinii and non-Pneumocystis carinii pneumonia (PCP) in patients HIV-positive and high risk to have PCP. We performed a prospective study in 30 patients with <200 CD4 lymphocytes, clinical symptoms of pulmonary disease and chest X-ray non-conclusive for pulmonary infection. Evaluated CT findings included ground-glass opacities, reticulation, tree-in-bud appearance, consolidation, cystic lesions, bronchiectasis and lymphadenopathies. The diagnosis of ''examination suggestive of PCP'' was applied to cases showing a diffuse or predominant ground-glass pattern in the upper fields, associated or not with reticulations and small cystic lesions. The sensitivity, specificity, positive predictive value and negative predictive value of high-resolution computed tomography (HRCT) for the diagnosis of PCP was 100, 83.3, 90.5 and 100%, respectively. Pneumocystis carinii pneumonia was not demonstrated in any of the cases classified as ''examination not suggestive of PCP''. Significant small airway disease was not observed in any of the PCP cases. We conclude that HRCT is a reliable method for differentiating PCP from other infectious processes in HIV-positive patients and a good method to rule our PCP. Its inclusion in the diagnostic algorithm of lung infections is justified in these patients. (orig.)

  9. Computer-assisted solid lung nodule 3D volumetry on CT : influence of scan mode and iterative reconstruction: a CT phantom study

    NARCIS (Netherlands)

    Coenen, Adriaan; Honda, Osamu; van der Jagt, Eric J.; Tomiyama, Noriyuki

    2013-01-01

    To evaluate the effect of high-resolution scan mode and iterative reconstruction on lung nodule 3D volumetry. Solid nodules with various sizes (5, 8, 10 and 12 mm) were placed inside a chest phantom. CT images were obtained with various tube currents, scan modes (conventional mode, high-resolution

  10. Gastrointestinal stromal tumor: role of spiral CT in diagnosis and evaluation of treatment with STI571

    International Nuclear Information System (INIS)

    Hu Jiawang; Zhou Linjiang; Wei Jiangong

    2011-01-01

    Objective: To investigate the CT appearance of gastrointestinal stromal tumors (GISTs) after oral imatinib mesylate (STI571) treatment. Methods: CT scans of 58 cases of GISTs proven by histology and immunohistochemistry were retrospectively analyzed. Dynamic contrast-enhanced CT of 8 patients after STI571 treatment was also evaluated. Results: The tumors originated from the stomach (n=28), small intestine (n=12), duodenum (n=6), colon (n=5), rectum (n=4), mesentery (n=2), and esophagus (n=2). Small GISTs appeared as round or oval, endo- or exophytic masses with well-defined margins and homogeneous contrast enhancement. Large lesions were often irregular infiltrative exophytic masses with heterogeneous enhancement. Ulceration, fistulization and neovascularity can be seen within the larger tumors. CT scans of 5 patients with good treatment response showed rapid transition form a heterogeneously hyper-attenuating pattern to homogeneously hypo-attenuating pattern with resolution of the enhancing tumor nodules and decreased tumor neovascularity. In 3 poor responders, CT showed enlarging or new enhancing nodules within the treated hypo-attenuating tumor, new lesions or metastasis outside the primary tumor. Conclusion: CT can demonstrate changes resulting from treatment of GISTs. It is valuable for guiding and assessing treatment response to STI571. (authors)

  11. CT cystography

    International Nuclear Information System (INIS)

    Tsili, A.

    2012-01-01

    Full text: Cancer of the urinary bladder is one of the commonest urothelial neoplasms. Conventional cystoscopy remains the mainstay in the diagnosis of urinary bladder carcinomas. But it is an invasive and uncomfortable procedure, associated with complications. Computed tomographic (CT) virtual cystoscopy has been proposed as an alternative imaging modality with potential advantages in the detection of urinary bladder neoplasms and good patient acceptance. It is a minimally invasive technique, allowing imaging of the urinary bladder in multiple planes and a 360 0 view. CT cystoscopy provides information about the location, size and morphologic features of urinary bladder lesions, indicating appropriate areas for biopsy. It can be performed in cases in which conventional cystoscopy is not feasible, such as in the presence of urethral strictures, marked prostatic hypertrophy or active bleeding, and in cases in which cystoscopic findings are inconclusive. The technique can be used to evaluate areas of the urinary bladder difficult to evaluate with cystoscopy, such as the anterior bladder neck and narrowmouthed diverticula. Finally, virtual cystoscopy provides both intraluminal and extraluminal pathologic changes, so intravesical disease and exrtavesical extension can be evaluated in the same study. One of the limitations of this technique is the difficulty to demonstrate small-sized lesions. The introduction of multi-detector row CT (MDCT) scanners was a major technological advancement because among other things it substantially improves z-axis resolution by reducing section collimation and allowing the detection of very small lesions. The near isotropic or isotropic pixels achieved with a multidetector CT scanner, enable the creation of multiplanar reformatted images with a resolution very close to that of the axial images and three-dimensional (3D) renderings of outstanding quality. Transverse, multiplanar reformations and virtual endoscopic images are complementary

  12. Spatial resolution measurements by Radia diagnostic software with SEDENTEXCT image quality phantom in cone beam CT for dental use.

    Science.gov (United States)

    Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru

    2018-02-01

    We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.

  13. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    Science.gov (United States)

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  14. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  15. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De [Chonnam Univ. Medical School, Kwangju (Korea, Republic of)

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis.

  16. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis

  17. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    Science.gov (United States)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the

  18. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  19. Bilateral primary renal lymphoma in a pediatric patient: staging and response evaluation with ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    Dhull, V S; Mukherjee, A; Karunanithi, S; Durgapal, P; Bal, C; Kumar, R

    2015-01-01

    Primary renal lymphoma (PRL) is a rare disease. We here present the case of an 8-year-old child who presented with bilateral renal masses. On biopsy, it was confirmed to be B-cell non-Hodgkin's lymphoma. (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography (PET/CT) for staging demonstrated (18)F-FDG avid bilateral renal masses, with no other abnormal focus. Follow up (18)F-FDG PET/CT showed complete resolution of the disease after six cycles of chemotherapy. Here we have highlighted the potential role of (18)F-FDG PET/CT in staging and response evaluation of a patient with PRL and presented a brief review. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  20. Lung manifestation in rheumatoid arthritis: High-resolution CT in mutual relation to skeletal changes and laboratory parameters

    International Nuclear Information System (INIS)

    Mueller-Leisse, C.; Meyer, O.; Genth, E.; Guenther, R.W.

    1996-01-01

    Purpose: It has been the aim of the following study to evaluate pulmonary changes in rheumatoid arthritis with high-resolution CT and to assess their correlation with joint manifestation and laboratory paramters. Material and methods: The authors prospectively performed computed tomography (CT) in 83 patients with rheumatoid arthritis and graded pulmonary changes for frequency and severity. Included were patients with 6-7/7 ARA, BSR>25/1 min and mean disease duration of 12 years (range, 1-44). Data of medical and drug histories, smoking habits, blood levels of rheumatoid factor (RF), antinuclear antibodies (ANA) and C-reactive protein as well as the degree of joint involvement were taken into account. Results: 58 patients (70%) had pathological CT scans showing the following abnormalities: Interlobular thickening (44.5%), intralobular thickening (34%), nonseptal linear attenuation (35%), nodular or linear pleural thickening (32.5%), ground-glass pattern (19%), centrilobular nodules (13%), honeycombing (13%) and bronchiolectasis (9%). Intralobular thickening, honeycombing and pleural thickening were associated with a higher degree of joint manifestation; pleural thickening, honeycombing and ground-glass pattern were associated with a higher level of rheumatoid factor. There was no relationship between pulmonary changes and either the duration of the disease, antinuclear antibodies (ANA) or C-reactive protein. Conclusion: CT may be a useful noninvasive tool for recognition of RA-associated lung disease. Interstitial lung changes are frequent and they are independent of the duration of the disease. Pulmonary interstitial changes are more frequent and more severe in RF-positive patients and in case of more severe joint involvement. (orig.) [de

  1. Evaluation of diseases of the aorta with ultrafast CT

    International Nuclear Information System (INIS)

    Eldredge, W.J.; Flicker, S.; Altin, R.S.; Naidech, H.J.

    1987-01-01

    Ultrafast CT offers several advantages over standard CT for imaging of various congenital and acquired diseases of the aorta. Scan acquisition rates of 50 msec permit evaluation of the entire aorta following a single peripheral intravenous injection of iodinated contrast medium. Pathologic aortic flow patterns may also be defined using an ECG triggered ''flow'' mode, adding another dimension to CT evaluation of the aorta. The papers shows examples of a variety of aortic diseases, including coarctation, Marfan syndrome, atherosclerotic aneurysm, dissection, and postoperative abnormalities. The advantages of the modality are stressed

  2. PET-CT in Staging, Response Evaluation, and Surveillance of Lymphoma.

    Science.gov (United States)

    Thanarajasingam, Gita; Bennani-Baiti, Nabila; Thompson, Carrie A

    2016-05-01

    Lymphoma represents a broad spectrum of diseases with diverse biology, clinical behavior, and imaging features. Functional imaging with 18-F-fluorodeoxyglucose (FDG)-positron emission tomography combined with computed tomography (PET-CT) is widely recognized as the most sensitive and specific imaging modality for patients with lymphoma and is used as part of staging, response evaluation, and surveillance in patients with Hodgkin (HL) and non-Hodgkin lymphoma (NHL). Recent efforts at standardizing the conduct and consensus interpretation of PET-CT have facilitated its use in patients on clinical studies and beyond. The role of PET-CT has been affirmed in some clinical situations, such as staging and end-of-treatment evaluation in Hodgkin lymphoma and diffuse large B cell lymphoma (DLBCL), and in the evaluation of aggressive transformation of an indolent lymphoma. However, the role of functional imaging in other histologies and clinical settings is not as clear given the higher rate of false positive results and the costs inherent to PET-CT. There is little evidence to suggest its utility or impact on outcome in most indolent lymphomas, or in the setting of post-treatment surveillance. In addition, there remains controversy about the value of PET-CT in early response assessment during active therapy, particularly in DLBCL. This review will evaluate the evidence surrounding the role of PET-CT in staging, response evaluation and surveillance of Hodgkin and non-Hodgkin lymphoma.

  3. Diagnosis of hearing impairment by high resolution CT scanning of inner ear anomalies

    International Nuclear Information System (INIS)

    Murata, Kiyotaka; Isono, Michio; Ohta, Fumihiko

    1988-01-01

    High resolution CT scanning of the temporal bone in our clinic has provided a more detailed radiological classification of inner ear anomalies than before. The statistical analysis of inner ear malformations based on the theory of quantification II has produced discriminant equations for the measurable diagnosis of hearing impairment and development of the inner ear. This analysis may make it possible to diagnose total and partial deafness on ipsi- and contralateral sides. (author)

  4. CT evaluation of infectious colitis

    International Nuclear Information System (INIS)

    Horiki, Noriyuki; Maruyama, Masataka; Fujita, Yoshiyuki; Suzuki, Yuko; Tanaka, Tsuyoshi; Imoto, Ichiro; Adachi, Yukihiko

    2002-01-01

    Computed tomography (CT) is useful for evaluating the diagnosis of gastrointestinal disease, such as infectious colitis, in patients with severe pain and bloody diarrhea. During the 7 years between November 1993 and October 2000, 34 patients with infectious colitis (18 male, 16 female; mean age 42±19 yrs), received emergency CT and colonoscopy because of severe abdominal pain and dysentery. The following organisms were isolated: pathogenic Escherichia coli (12), 6 of which were O157: H7 (O-157), Salmonella species (11), Campylobacter species (5), Vibrio parahaemolyticus (3), Yersinia enterocolotica (2) and Shigella species (1). Thickening of the intestinal wall greater than 10 mm was seen in the ascending colon in the 6 cases with E. coli O157, in 5/11 cases with Salmonella, 4/5 with Campylobacter and 1/6 with non-O157 pathogenic E. Coli. marked intestinal wall thickening, greater than 20 mm, was seen in the ascending colon of the 4 of the patients with an O-157 infection. In all patients with O-157 colitis, slight ascites was noted in the pelvic space. In additions, ascites was also seen in 3/13 patients with Salmonella and 1/5 patients with Campylobacter colitis. The CT findings, in the patients with infectious colitis, are non-specific but knowledge and recognition of the findings will help in patient evaluation and proper treatment. (author)

  5. CT evaluation of infectious colitis

    Energy Technology Data Exchange (ETDEWEB)

    Horiki, Noriyuki; Maruyama, Masataka; Fujita, Yoshiyuki; Suzuki, Yuko [Saint Luke' s International Hospital, Tokyo (Japan); Tanaka, Tsuyoshi; Imoto, Ichiro [National Mie Chuo Hospital, Hisai (Japan); Adachi, Yukihiko [Mie Univ., Tsu (Japan). School of Medicine

    2002-08-01

    Computed tomography (CT) is useful for evaluating the diagnosis of gastrointestinal disease, such as infectious colitis, in patients with severe pain and bloody diarrhea. During the 7 years between November 1993 and October 2000, 34 patients with infectious colitis (18 male, 16 female; mean age 42{+-}19 yrs), received emergency CT and colonoscopy because of severe abdominal pain and dysentery. The following organisms were isolated: pathogenic Escherichia coli (12), 6 of which were O157: H7 (O-157), Salmonella species (11), Campylobacter species (5), Vibrio parahaemolyticus (3), Yersinia enterocolotica (2) and Shigella species (1). Thickening of the intestinal wall greater than 10 mm was seen in the ascending colon in the 6 cases with E. coli O157, in 5/11 cases with Salmonella, 4/5 with Campylobacter and 1/6 with non-O157 pathogenic E. Coli. marked intestinal wall thickening, greater than 20 mm, was seen in the ascending colon of the 4 of the patients with an O-157 infection. In all patients with O-157 colitis, slight ascites was noted in the pelvic space. In additions, ascites was also seen in 3/13 patients with Salmonella and 1/5 patients with Campylobacter colitis. The CT findings, in the patients with infectious colitis, are non-specific but knowledge and recognition of the findings will help in patient evaluation and proper treatment. (author)

  6. Optimization of the spatial resolution for the GE discovery PET/CT 710 by using NEMA NU 2-2007 standards

    Science.gov (United States)

    Yoon, Hyun Jin; Jeong, Young Jin; Son, Hye Joo; Kang, Do-Young; Hyun, Kyung-Yae; Lee, Min-Kyung

    2015-01-01

    The spatial resolution in positron emission tomography (PET) is fundamentally limited by the geometry of the detector element, the positron's recombination range with electrons, the acollinearity of the positron, the crystal decoding error, the penetration into the detector ring, and the reconstruction algorithms. In this paper, optimized parameters are suggested to produce high-resolution PET images by using an iterative reconstruction algorithm. A phantom with three point sources structured with three capillary tubes was prepared with an axial extension of less than 1 mm and was filled with 18F-fluorodeoxyglucose (18F-FDG) with concentrations above 200 MBq/cc. The performance measures of all the PET images were acquired according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standards procedures. The parameters for the iterative reconstruction were adjusted around the values recommended by General Electric GE, and the optimized values of the spatial resolution and the full width at half maximum (FWHM) or the full width at tenth of maximum (FWTM) values were found for the best PET resolution. The axial and the transverse spatial resolutions, according to the filtered back-projection (FBP) at 1 cm off-axis, were 4.81 and 4.48 mm, respectively. The axial and the transaxial spatial resolutions at 10 cm off-axis were 5.63 mm and 5.08 mm, respectively, and the trans-axial resolution at 10 cm was evaluated as the average of the radial and the tangential measurements. The recommended optimized parameters of the spatial resolution according to the NEMA phantom for the number of subsets, the number of iterations, and the Gaussian post-filter are 12, 3, and 3 mm for the iterative reconstruction VUE Point HD without the SharpIR algorithm (HD), and 12, 12, and 5.2 mm with SharpIR (HD.S), respectively, according to the Advantage Workstation Volume Share 5 (AW4.6). The performance measurements for the GE Discovery PET/CT 710 using the NEMA NU 2

  7. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    Energy Technology Data Exchange (ETDEWEB)

    Chain, J N M; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, V8W 3P6 (Canada); Schreiner, L J, E-mail: kim.mcauley@chee.queensu.ca [Cancer Centre of Southeastern Ontario, Kingston, K7L 5P9 (Canada)

    2011-04-07

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range ({approx}0.88 H Gy{sup -1}) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent ({approx}0.80 H Gy{sup -1}). This new gel formulation results in enhanced dose resolution ({approx}0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  8. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    International Nuclear Information System (INIS)

    Chain, J N M; McAuley, K B; Jirasek, A; Schreiner, L J

    2011-01-01

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (∼0.88 H Gy -1 ) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (∼0.80 H Gy -1 ). This new gel formulation results in enhanced dose resolution (∼0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  9. Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Jan S., E-mail: jsb@tum.de [Department of Radiology, Technische Universität München, Munich (Germany); Department of Radiology, University of California, San Francisco, CA (United States); Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Sidorenko, Irina [Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Mueller, Dirk [Department of Radiology, Universität Köln (Germany); Baum, Thomas [Department of Radiology, Technische Universität München, Munich (Germany); Department of Radiology, University of California, San Francisco, CA (United States); Max Planck Institute for Extraterrestrial Physics, Garching (Germany); Issever, Ahi Sema [Department of Radiology, University of California, San Francisco, CA (United States); Department of Radiology, Charite, Berlin (Germany); Eckstein, Felix [Institute of Anatomy and Musculoskeletal Research, Paracelsus Medical University, Salzburg (Austria); Rummeny, Ernst J. [Department of Radiology, Technische Universität München, Munich (Germany); Link, Thomas M. [Department of Radiology, University of California, San Francisco, CA (United States); Raeth, Christoph W. [Max Planck Institute for Extraterrestrial Physics, Garching (Germany)

    2014-01-15

    Objectives: Finite-element-models (FEM) are a promising technology to predict bone strength and fracture risk. Usually, the highest spatial resolution technically available is used, but this requires excessive computation time and memory in numerical simulations of large volumes. Thus, FEM were compared at decreasing resolutions with respect to local strain distribution and prediction of failure load to (1) validate MDCT-based FEM and to (2) optimize spatial resolution to save computation time. Materials and methods: 20 cylindrical trabecular bone specimens (diameter 12 mm, length 15–20 mm) were harvested from elderly formalin-fixed human thoracic spines. All specimens were examined by micro-CT (isotropic resolution 30 μm) and whole-body multi-row-detector computed tomography (MDCT, 250 μm × 250 μm × 500 μm). The resolution of all datasets was lowered in eight steps to ∼2000 μm × 2000 μm × 500 μm and FEM were calculated at all resolutions. Failure load was determined by biomechanical testing. Probability density functions of local micro-strains were compared in all datasets and correlations between FEM-based and biomechanically measured failure loads were determined. Results: The distribution of local micro-strains was similar for micro-CT and MDCT at comparable resolutions and showed a shift toward higher average values with decreasing resolution, corresponding to the increasing apparent trabecular thickness. Small micro-strains (ε{sub eff} < 0.005) could be calculated down to 250 μm × 250 μm × 500 μm. Biomechanically determined failure load showed significant correlations with all FEM, up to r = 0.85 and did not significantly change with lower resolution but decreased with high thresholds, due to loss of trabecular connectivity. Conclusion: When choosing connectivity-preserving thresholds, both micro-CT- and MDCT-based finite-element-models well predicted failure load and still accurately revealed the distribution of local micro-strains in

  10. Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?

    International Nuclear Information System (INIS)

    Bauer, Jan S.; Sidorenko, Irina; Mueller, Dirk; Baum, Thomas; Issever, Ahi Sema; Eckstein, Felix; Rummeny, Ernst J.; Link, Thomas M.; Raeth, Christoph W.

    2014-01-01

    Objectives: Finite-element-models (FEM) are a promising technology to predict bone strength and fracture risk. Usually, the highest spatial resolution technically available is used, but this requires excessive computation time and memory in numerical simulations of large volumes. Thus, FEM were compared at decreasing resolutions with respect to local strain distribution and prediction of failure load to (1) validate MDCT-based FEM and to (2) optimize spatial resolution to save computation time. Materials and methods: 20 cylindrical trabecular bone specimens (diameter 12 mm, length 15–20 mm) were harvested from elderly formalin-fixed human thoracic spines. All specimens were examined by micro-CT (isotropic resolution 30 μm) and whole-body multi-row-detector computed tomography (MDCT, 250 μm × 250 μm × 500 μm). The resolution of all datasets was lowered in eight steps to ∼2000 μm × 2000 μm × 500 μm and FEM were calculated at all resolutions. Failure load was determined by biomechanical testing. Probability density functions of local micro-strains were compared in all datasets and correlations between FEM-based and biomechanically measured failure loads were determined. Results: The distribution of local micro-strains was similar for micro-CT and MDCT at comparable resolutions and showed a shift toward higher average values with decreasing resolution, corresponding to the increasing apparent trabecular thickness. Small micro-strains (ε eff < 0.005) could be calculated down to 250 μm × 250 μm × 500 μm. Biomechanically determined failure load showed significant correlations with all FEM, up to r = 0.85 and did not significantly change with lower resolution but decreased with high thresholds, due to loss of trabecular connectivity. Conclusion: When choosing connectivity-preserving thresholds, both micro-CT- and MDCT-based finite-element-models well predicted failure load and still accurately revealed the distribution of local micro-strains in spatial

  11. CT evaluation of thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Hee [Insung Hospital, Chuncheon (Korea, Republic of); Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness.

  12. CT evaluation of thymus in myasthenia gravis

    International Nuclear Information System (INIS)

    Kim, Guk Hee; Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck

    1989-01-01

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness

  13. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  14. Evaluation of left ventricular function by cardiac CT

    International Nuclear Information System (INIS)

    Naito, Hiroaki; Kozuka, Takahiro

    1982-01-01

    Left ventricular function was evaluated by CT, which was compared with the data of left ventriculography for various cardiac diseases. The end diastolic volume of the left ventricle can be readily computed from CT, with a satisfactory correlation with that of left ventriculography (r = 0.95). The left ventricular ejection fraction, calculated from the areal ratio of the left ventricular lumen in end-diastolic imaging to that in end-sytolic imaging, also roughly reflects left ventricular contractile function, but shows correlation with left ventriculography by only r = 0.79. Although the cardiac output is not sensitive for functional evaluation, it can be directly calculated by means of dynamic scanning and shows a satisfactory correlation with the ear piece pigment dilution (r = 0.85). Evaluation of left ventricular function by CT shows a high precision in comparison with left ventriculography, but still lacks temporal resolving power. (Chiba, N.)

  15. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  16. Accuracy of high-resolution CT in distinguishing between Pneumocystis carinii pneumonia and non-Pneumocystis carinii pneumonia in AIDS patients

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, A.; Mauleon, S.; Andreu, J.; Caceres, J. [Department of Radiology, Hospital General Universitari Vall d' Hebron, Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Paseo Vall d' Hebron 119-129, 08035 Barcelona (Spain); Falco, V.; Crespo, M.; Ribera, E.; Pahissa, A. [Department of Medicine, Service of Infectious Diseases, Hospital General Universitari Vall d' Hebron, Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Paseo Vall d' Hebron 119-129, 08035 Barcelona (Spain)

    2003-05-01

    The aim of this study was to assess the value of high-resolution CT in distinguishing between Pneumocystis carinii and non-Pneumocystis carinii pneumonia (PCP) in patients HIV-positive and high risk to have PCP. We performed a prospective study in 30 patients with <200 CD4 lymphocytes, clinical symptoms of pulmonary disease and chest X-ray non-conclusive for pulmonary infection. Evaluated CT findings included ground-glass opacities, reticulation, tree-in-bud appearance, consolidation, cystic lesions, bronchiectasis and lymphadenopathies. The diagnosis of ''examination suggestive of PCP'' was applied to cases showing a diffuse or predominant ground-glass pattern in the upper fields, associated or not with reticulations and small cystic lesions. The sensitivity, specificity, positive predictive value and negative predictive value of high-resolution computed tomography (HRCT) for the diagnosis of PCP was 100, 83.3, 90.5 and 100%, respectively. Pneumocystis carinii pneumonia was not demonstrated in any of the cases classified as ''examination not suggestive of PCP''. Significant small airway disease was not observed in any of the PCP cases. We conclude that HRCT is a reliable method for differentiating PCP from other infectious processes in HIV-positive patients and a good method to rule our PCP. Its inclusion in the diagnostic algorithm of lung infections is justified in these patients. (orig.)

  17. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  18. Fever of unknown origin: A value of 18F-FDG-PET/CT with integrated full diagnostic isotropic CT imaging

    International Nuclear Information System (INIS)

    Ferda, Jiri; Ferdova, Eva; Zahlava, Jan; Matejovic, Martin; Kreuzberg, Boris

    2010-01-01

    Aim: The aim of presented work is to evaluate the clinical value of 18 F-FDG-PET/CT in patients with fever of unknown origin (FUO) and to compare PET/CT finding with the results of the following investigation. Material and method: 48 patients (24 men, 24 women, mean age 57.6 years with range 15-89 years) underwent 18 F-FDG-PET/CT due to the fever of unknown origin. All examinations were performed using complex PET/CT protocol combined PET and whole diagnostic contrast enhanced CT with sub-millimeter spatial resolution (except patient with history of iodine hypersensitivity or sever renal impairment). CT data contained diagnostic images reconstructed with soft tissue and high-resolution algorithm. PET/CT finding were compared with results of biopsies, immunology, microbiology or autopsy. Results: The cause of FUO was explained according to the PET/CT findings and followed investigations in 44 of 48 cases-18 cases of microbial infections, nine cases of autoimmune inflammations, four cases of non-infectious granulomatous diseases, eight cases of malignancies and five cases of proved immunity disorders were found. In 46 cases, the PET/CT interpretation was correct. Only in one case, the cause was overlooked and the uptake in atherosclerotic changes of arteries was misinterpreted as vasculitis in the other. The reached sensitivity was 97% (43/44), and specificity 75% (3/4) respectively. Conclusion: In patients with fever of unknown origin, 18 F-FDG-PET/CT might enable the detection of its cause.

  19. Spiral CT of the pancreas. The value of small field-of-view targeted reconstruction

    International Nuclear Information System (INIS)

    Nishiharu, T.; Yamashita, Y.; Ogata, I.; Sumi, S.; Mitsuzaki, K.; Takahashi, M.

    1998-01-01

    Purpose: To compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases. Material and methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols. Results: The high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). In patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details. Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities. (orig.)

  20. CT in the evaluation of severe liver trauma

    International Nuclear Information System (INIS)

    Machado, Marcel Autran C.; Souza Rocha, Manoel de; Machado, Manoel C.C.; Macedo Neto, Augusto Cesar de; Maciel, Rosangela Pereira; Simonetti, Celso.

    1995-01-01

    Abdominal CT is a common examination in the evaluation of patients with blunt abdominal trauma and clinical suspicion for solid organ injury when reasons for immediate laparotomy are not present. A case of major blunt hepatic injury in a 22-year-old patient is reported. The authors present a brief review of the literature and discussion about the role of CT scan in the evaluation of hepatic trauma, surgical planning and postoperative follow-up. (author). 15 refs., 3 figs., 1 tab

  1. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET/CT

  2. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  3. Algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images

    International Nuclear Information System (INIS)

    Ogino, Takashi; Egawa, Sunao

    1991-01-01

    New algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images were developed. One, designated plane weighting method, is to correct CT value in proportion to the position of the beam element passing through the voxel. The other, designated solid weighting method, is to correct CT value in proportion to the length of the beam element passing through the voxel and the volume of voxel. Phantom experiments showed fair spatial resolution in the transverse direction. In the longitudinal direction, however, spatial resolution of under slice thickness could not be obtained. Contrast resolution was equivalent for both methods. In patient studies, the reconstructed radiotherapy simulation image was almost similar in visual perception of the density resolution to a simulation film taken by X-ray simulator. (author)

  4. Serial quantitative CT evaluation for patients with idiopathic pulmonary fibrosis (IPF) using Gaussian Histogram Normalized Correlation (GHNC)

    International Nuclear Information System (INIS)

    Iwasawa, Tae; Ogura, Takashi; Nishimura, Junichi; Asakura, Akira; Gotoh, Toshiyuki; Yazawa, Takuya; Inoue, Tomio

    2006-01-01

    We assessed serial changes in high-resolution CT findings quantitatively using originally developed software Gaussian Histogram Normalized Correlation (GHNC) in 15 patients with idiopathic pulmonary fibrosis (IPF). Mean follow-up period was 1.4 years. The volume of honeycombing increased with 0.8±0.9%TLC (predicted Total lung capacity) per year, the normal lung volume reduced by 4.1±7.3%TLC per year. GHNC is useful for the quantitative evaluation. (author)

  5. Fire victim identification by post-mortem dental CT: Radiologic evaluation of restorative materials after exposure to high temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Woisetschlaeger, Mischa, E-mail: Mischa.woisetschlager@lio.se [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Lussi, Adrian, E-mail: anders.persson@cmiv.lio.se [Department of Preventive, Restorative and Pediatric Dentistry, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern (Switzerland); Persson, Anders, E-mail: adrian.lussi@zmk.unibe.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Jackowski, Christian, E-mail: christian.jackowski@irm.uzh.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Institute of Legal Medicine, University of Zuerich, Winterthurerstrasse 190/52, 8057 Zuerich (Switzerland)

    2011-11-15

    Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures {>=}400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.

  6. Fire victim identification by post-mortem dental CT: Radiologic evaluation of restorative materials after exposure to high temperatures

    International Nuclear Information System (INIS)

    Woisetschlaeger, Mischa; Lussi, Adrian; Persson, Anders; Jackowski, Christian

    2011-01-01

    Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures ≥400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.

  7. Hypoxic-ischemic encephalopathy in neonates and infants: an evaluation with spiral CT

    International Nuclear Information System (INIS)

    Zhu Linghua

    2006-01-01

    Objective: To evaluate spiral CT imaging in the diagnosis of hypoxic-ischemic encephalopathy (HIE) in the neonates and infants. Methods: 112 children with history of asphyxia in peri-natal period and evident clinical symptoms were evaluated with Spiral CT. CT findings were studied. Results: 46 minor cases, 57 moderate cases and 9 severe cases were found out of 112 patients. Intracranial hemorrhage was revealed in 38 cases. Mortality occurred in 1 case. Conclusion: Spiral CT is helpful for evaluating brain damage and predicting prognosis in neonates with HIE. (authors)

  8. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  9. CT evaluation of optic nerve compression in thyroid eye disease

    International Nuclear Information System (INIS)

    Barrett, L.; Giatt, H.J.; Burde, R.M.; Gado, M.

    1986-01-01

    In thyroid eye disease, visual loss due to optic nerve compression by enlarged muscles near the orbital apex requires prompt surgical decompression and must be differentiated from visual loss due to other mechanisms. Seventy-two high-resolution orbital CT scans of patients with thyroid eye disease were analyzed. From a coronal reconstruction, an easily measured ''apical index'' was determined. Average apical indices for orbits without optic neuropathy (41.0%) and with optic neuropathy (70.2%) were significantly different (P < .001). With the aid of the apical index, CT findings can be used to predict which patients with thyroid eye disease have optic nerve compression

  10. Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue

    Science.gov (United States)

    McClatchy, David M., III; Rizzo, Elizabeth J.; Meganck, Jeff; Kempner, Josh; Vicory, Jared; Wells, Wendy A.; Paulsen, Keith D.; Pogue, Brian W.

    2017-12-01

    A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast of 1.64, and a minimum detectable resolution of 240 μm for a 1.2 min scan. The SLI system, spanning wavelengths 490 nm to 800 nm and spatial frequencies up to 1.37 mm-1 , was evaluated with aqueous tissue simulating phantoms having variations in particle size distribution, scatter density, and blood volume fraction. The reduced scattering coefficient, μs\\prime and phase function parameter, γ, were accurately recovered over all wavelengths independent of blood volume fractions from 0% to 4%, assuming a flat sample geometry perpendicular to the imaging plane. The resolution of the optical system was tested with a step phantom, from which the modulation transfer function was calculated yielding a maximum resolution of 3.78 cycles per mm. The three dimensional spatial co-registration between the CT and optical imaging space was tested and shown to be accurate within 0.7 mm. A freshly resected breast specimen, with lobular carcinoma, fibrocystic disease, and adipose, was imaged with the system. The micro-CT provided visualization of the tumor mass and its spiculations, and SLI yielded superficial quantification of light scattering parameters for the malignant and benign tissue types. These results appear to be the first demonstration of SLI combined with standard medical tomography for imaging excised tumor specimens. While further investigations are needed to determine and test the spectral, spatial, and CT features required to classify tissue, this study demonstrates the ability of multimodal CT/SLI to quantify, visualize, and spatially navigate breast tumor specimens, which could potentially aid in the assessment of tumor margin status during

  11. Chronic ankle instability: evaluation with stress radiography, CT and CT arthrography

    International Nuclear Information System (INIS)

    Faure, Ch.; Deplus, F.; Bochu, M.; Besse, J.L.; Moyen, B.

    1997-01-01

    We retrospectively evaluated the anterior talo-fibular ligament and the tarsal sinus of 17 patients who had complained of chronic ankle external instability. This study based on both surgery and CT-arthrography findings shows the pathologic or normal aspects of the talo-fibular anterior ligament (normal, lax, fibrosis residue, ruptured). It confirms the good anatomic analysis of the tarsal sinus, i particular the anterior talo-calcaneal interosseous ligament and the search for fibrosis. We underline that capsular distension due to subtalar laxity is not detected with medical imaging. Compared with surgery (all patients), CT arthrography demonstrated the different aspects of the anterior talo fibular ligament injuries (normal, lax, discontinuous). (authors)

  12. Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results

    CERN Document Server

    Bennett, James R; Xu, Qiong; Yu, Hengyong; Walsh, Michael; Butler, Anthony; Butler, Phillip; Cao, Guohua; Mohs, Aaron; Wang, Ge

    2014-01-01

    Spectral CT has proven an important development in biomedical imaging, and there have been several publications in the past years demonstrating its merits in pre-clinical and clinical applications. In 2012, Xu et al. reported that near-term implementation of spectral micro-CT could be enhanced by a hybrid architecture: a narrow-beam spectral "interior" imaging chain integrated with a traditional wide-beam "global" imaging chain. This hybrid integration coupled with compressive sensing (CS)-based interior tomography demonstrated promising results for improved contrast resolution, and decreased system cost and radiation dose. The motivation for the current study is implementation and evaluation of the hybrid architecture with a first-of-its-kind hybrid spectral micro-CT system. Preliminary results confirm improvements in both contrast and spatial resolution. This technology is shown to merit further investigation and potential application in future spectral CT scanner design.

  13. 'Crazy-Paving' Patterns on High-Resolution CT Scans in Patients with Pulmonary Complications after Hematopoietic Stem Cell Transplantation

    International Nuclear Information System (INIS)

    Marchiori, Edson; Escuissato, Dante L.; Gasparetto, Taisa Davaus; Considera, Daniela Peixoto; Franquet, Tomas

    2009-01-01

    To describe the pulmonary complications following hematopoietic stem cell transplantation (HSCT) that can present with a 'crazy-paving' pattern in high-resolution CT scans. Retrospective review of medical records from 2,537 patients who underwent HSCT. The 'crazy-paving' pattern consists of interlobular and intralobular septal thickening superimposed on an area of ground-glass attenuation on high-resolution CT scans. The CT scans were retrospectively reviewed by two radiologists, who reached final decisions by consensus. We identified 10 cases (2.02%), seven male and three female, with pulmonary complications following HSCT that presented with the 'crazy-paving' pattern. Seven (70%) patients had infectious pneumonia (adenovirus, herpes simplex, influenza virus, cytomegalovirus, respiratory syncytial virus, and toxoplasmosis), and three patients presented with non-infectious complications (idiopathic pneumonia syndrome and acute pulmonary edema). The 'crazy-paving' pattern was bilateral in all cases, with diffuse distribution in nine patients (90%), predominantly in the middle and inferior lung regions in seven patients (70%), and involving the anterior and posterior regions of the lungs in nine patients (90%). The 'crazy-paving' pattern is rare in HSCT recipients with pulmonary complications and is associated with infectious complications more commonly than non-infectious conditions

  14. CT diagnosis of hepatic alveolar echinococcosis and evaluation after albendazole chemotherapy

    International Nuclear Information System (INIS)

    Wu Jingquan; Liu Yuehan; Wang Xiaogen

    1998-01-01

    Purpose: To analyze the CT features and evaluate albendazole chemotherapy of hepatic alveolar echinococcosis with computed tomography (CT). Methods: Twenty-one patients of hepatic alveolar echincoccosis were diagnosed by epidemiological, clinical, serological tests, and studied with US and CT. Twenty patients were followed up by CT scanning from 1 to 9 years (mean 3.9 years) after albendazole chemotherapy. Results: CT scanning of liver before treatment displayed heterogeneous hypodense lesions, with irregular, obscure contour and calcifications According to CT features, the hepatic lesions were divided into 3 forms: solid mass in 7 cases, pseudocyst in 6 cases and mixed in 8 cases. Three patients had contrast study. The hepatic lesions were not markedly enhanced, but the lesions were seen more clearly and appeared more extensive. In follow-up examination of 20 cases, 4 were apparently cured, 5 improved, 5 stabilized, and 6 cases remained pseudocyst. Conclusion: CT scanning was of value not only for diagnosis of hepatic alveolar echinococcosis, but also useful in evaluation of chemotherapeutic efficacy

  15. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    Science.gov (United States)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  16. Improvement of the temporal resolution of cardiac CT reconstruction algorithms using an optimized filtering step

    International Nuclear Information System (INIS)

    Roux, S.; Desbat, L.; Koenig, A.; Grangeat, P.

    2005-01-01

    In this paper we study a property of the filtering step of multi-cycle reconstruction algorithm used in the field of cardiac CT. We show that the common filtering step procedure is not optimal in the case of divergent geometry and decrease slightly the temporal resolution. We propose to use the filtering procedure related to the work of Noo at al ( F.Noo, M. Defrise, R. Clakdoyle, and H. Kudo. Image reconstruction from fan-beam projections on less than a short-scan. Phys. Med.Biol., 47:2525-2546, July 2002)and show that this alternative allows to reach the optimal temporal resolution with the same computational effort. (N.C.)

  17. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  18. TH-CD-202-04: Evaluation of Virtual Non-Contrast Images From a Novel Split-Filter Dual-Energy CT Technique

    International Nuclear Information System (INIS)

    Huang, J; Szczykutowicz, T; Bayouth, J; Miller, J

    2016-01-01

    Purpose: To compare the ability of two dual-energy CT techniques, a novel split-filter single-source technique of superior temporal resolution against an established sequential-scan technique, to remove iodine contrast from images with minimal impact on CT number accuracy. Methods: A phantom containing 8 tissue substitute materials and vials of varying iodine concentrations (1.7–20.1 mg I /mL) was imaged using a Siemens Edge CT scanner. Dual-energy virtual non-contrast (VNC) images were generated using the novel split-filter technique, in which a 120kVp spectrum is filtered by tin and gold to create high- and low-energy spectra with < 1 second temporal separation between the acquisition of low- and high-energy data. Additionally, VNC images were generated with the sequential-scan technique (80 and 140kVp) for comparison. CT number accuracy was evaluated for all materials at 15, 25, and 35mGy CTDIvol. Results: The spectral separation was greater for the sequential-scan technique than the split-filter technique with dual-energy ratios of 2.18 and 1.26, respectively. Both techniques successfully removed iodine contrast, resulting in mean CT numbers within 60HU of 0HU (split-filter) and 40HU of 0HU (sequential-scan) for all iodine concentrations. Additionally, for iodine vials of varying diameter (2–20 mm) with the same concentration (9.9 mg I /mL), the system accurately detected iodine for all sizes investigated. Both dual-energy techniques resulted in reduced CT numbers for bone materials (by >400HU for the densest bone). Increasing the imaging dose did not improve the CT number accuracy for bone in VNC images. Conclusion: VNC images from the split-filter technique successfully removed iodine contrast. These results demonstrate a potential for improving dose calculation accuracy and reducing patient imaging dose, while achieving superior temporal resolution in comparison sequential scans. For both techniques, inaccuracies in CT numbers for bone materials

  19. TH-CD-202-04: Evaluation of Virtual Non-Contrast Images From a Novel Split-Filter Dual-Energy CT Technique

    Energy Technology Data Exchange (ETDEWEB)

    Huang, J; Szczykutowicz, T; Bayouth, J; Miller, J [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: To compare the ability of two dual-energy CT techniques, a novel split-filter single-source technique of superior temporal resolution against an established sequential-scan technique, to remove iodine contrast from images with minimal impact on CT number accuracy. Methods: A phantom containing 8 tissue substitute materials and vials of varying iodine concentrations (1.7–20.1 mg I /mL) was imaged using a Siemens Edge CT scanner. Dual-energy virtual non-contrast (VNC) images were generated using the novel split-filter technique, in which a 120kVp spectrum is filtered by tin and gold to create high- and low-energy spectra with < 1 second temporal separation between the acquisition of low- and high-energy data. Additionally, VNC images were generated with the sequential-scan technique (80 and 140kVp) for comparison. CT number accuracy was evaluated for all materials at 15, 25, and 35mGy CTDIvol. Results: The spectral separation was greater for the sequential-scan technique than the split-filter technique with dual-energy ratios of 2.18 and 1.26, respectively. Both techniques successfully removed iodine contrast, resulting in mean CT numbers within 60HU of 0HU (split-filter) and 40HU of 0HU (sequential-scan) for all iodine concentrations. Additionally, for iodine vials of varying diameter (2–20 mm) with the same concentration (9.9 mg I /mL), the system accurately detected iodine for all sizes investigated. Both dual-energy techniques resulted in reduced CT numbers for bone materials (by >400HU for the densest bone). Increasing the imaging dose did not improve the CT number accuracy for bone in VNC images. Conclusion: VNC images from the split-filter technique successfully removed iodine contrast. These results demonstrate a potential for improving dose calculation accuracy and reducing patient imaging dose, while achieving superior temporal resolution in comparison sequential scans. For both techniques, inaccuracies in CT numbers for bone materials

  20. CT diagnosis in the evaluation of vertebral trauma

    International Nuclear Information System (INIS)

    Emori, Takumi; Kadoya, Satoru; Nakamura, Tsutomu; Ito, Shotaro; Kwak, Ryungchan

    1984-01-01

    The diagnostic capability of the CT scan of the vertebral trauma and a comparison with the results of a routine roentgenogram and tomogram were studied in 11 patients. In total, there were 15 fractured vertebrae: 3 in the upper cervical, 3 in the lower cervical, and 9 in the thoracic and thoraco-lumbar vertebrae. In the detailed evaluation of the vertebral fractures, CT provided more information than plain films in all 15 fractured vertebrae, with a better visualization of the spinal bony details, particularly at the upper cervical, thoracic, and thoraco-lumbar levels, where the interpretation of the spinal abnormalities is usually difficult because of adjacent structures such as the skull and thorax. Only CT was able to demonstrate impingements on the vertebral canal by bony fragments. Post-traumatic syringomyelia was incidentally demonstrated in one patient on a plain CT. In 6 patients, conventional tomography was done, but no additional information with regard to spinal instability and spinal-cord compression was obtained. The usage of sagittal tomography was also limited, because it required a change in the patient's position, which might worsen the neurological deficits. On the other hand, a plain roentgenogram and conventional tomography were superior in the evaluation of spinal malalignment and fractures running horizontally. In summary, both plain roentgenograms and CT images provided detailed information about vertebral injury, whereas conventional tomography is judged to be inferior and not always necessary. Based on these results, our new diagnostic and therapeutic approaches using CT for the vertebral injuries were presented. (author)

  1. Image-based motion compensation for high-resolution extremities cone-beam CT

    Science.gov (United States)

    Sisniega, A.; Stayman, J. W.; Cao, Q.; Yorkston, J.; Siewerdsen, J. H.; Zbijewski, W.

    2016-03-01

    Purpose: Cone-beam CT (CBCT) of the extremities provides high spatial resolution, but its quantitative accuracy may be challenged by involuntary sub-mm patient motion that cannot be eliminated with simple means of external immobilization. We investigate a two-step iterative motion compensation based on a multi-component metric of image sharpness. Methods: Motion is considered with respect to locally rigid motion within a particular region of interest, and the method supports application to multiple locally rigid regions. Motion is estimated by maximizing a cost function with three components: a gradient metric encouraging image sharpness, an entropy term that favors high contrast and penalizes streaks, and a penalty term encouraging smooth motion. Motion compensation involved initial coarse estimation of gross motion followed by estimation of fine-scale displacements using high resolution reconstructions. The method was evaluated in simulations with synthetic motion (1-4 mm) applied to a wrist volume obtained on a CMOS-based CBCT testbench. Structural similarity index (SSIM) quantified the agreement between motion-compensated and static data. The algorithm was also tested on a motion contaminated patient scan from dedicated extremities CBCT. Results: Excellent correction was achieved for the investigated range of displacements, indicated by good visual agreement with the static data. 10-15% improvement in SSIM was attained for 2-4 mm motions. The compensation was robust against increasing motion (4% decrease in SSIM across the investigated range, compared to 14% with no compensation). Consistent performance was achieved across a range of noise levels. Significant mitigation of artifacts was shown in patient data. Conclusion: The results indicate feasibility of image-based motion correction in extremities CBCT without the need for a priori motion models, external trackers, or fiducials.

  2. CT of the chest in the evaluation of idiopathic pulmonary arterial hypertension in children

    Energy Technology Data Exchange (ETDEWEB)

    Chaudry, Gulraiz [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Children' s Hospital Boston, Department of Radiology, Boston, MA (United States); MacDonald, Cathy; Gundogan, Munire; Manson, David [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Adatia, Ian [UCSF Children' s Hospital, Department of Pediatric Cardiology, San Francisco, CA (United States)

    2007-04-15

    Idiopathic pulmonary arterial hypertension (IPAH) is a rare disease in children. By definition it is a diagnosis of exclusion, and CT of the chest is primarily performed to exclude other causes. Previous studies have defined CT features suggestive of the diagnosis of IPAH, but these have all been limited to the adult population. Contrast-enhanced chest CT and high-resolution CT findings in IPAH were evaluated in an attempt to define features consistently seen in children with this condition. The chest CT scans performed at initial presentation were reviewed in 17 children with echocardiographic or angiographic evidence of IPAH. There were nine boys and eight girls, ranging in age from 1 month to 17 years. The extrapulmonary findings included cardiomegaly with right-sided cardiac enlargement, which was seen in 13 children. The central pulmonary arteries were enlarged in 15 children, with peripheral enlargement in two. In six children this resulted in bronchial compression. In addition, mediastinal and hilar lymphadenopathy was noted in three children. Prominent intrapulmonary features included a peripheral vasculopathy, with enlarged tortuous vessels, seen in eight children. Ill-defined ground-glass centrilobular opacities were also noted in eight children, representing the most common parenchymal abnormality. Other findings included septal lines in five, diffuse ground-glass opacification in four and focal hyperlucent zones in three. Mosaic attenuation was seen in one child. A variety of imaging findings are identified in IPAH. Features particularly consistent with the diagnosis include peripheral vasculopathy and centrilobular opacities in the setting of cardiomegaly and central pulmonary arterial enlargement. (orig.)

  3. CT of the chest in the evaluation of idiopathic pulmonary arterial hypertension in children

    International Nuclear Information System (INIS)

    Chaudry, Gulraiz; MacDonald, Cathy; Gundogan, Munire; Manson, David; Adatia, Ian

    2007-01-01

    Idiopathic pulmonary arterial hypertension (IPAH) is a rare disease in children. By definition it is a diagnosis of exclusion, and CT of the chest is primarily performed to exclude other causes. Previous studies have defined CT features suggestive of the diagnosis of IPAH, but these have all been limited to the adult population. Contrast-enhanced chest CT and high-resolution CT findings in IPAH were evaluated in an attempt to define features consistently seen in children with this condition. The chest CT scans performed at initial presentation were reviewed in 17 children with echocardiographic or angiographic evidence of IPAH. There were nine boys and eight girls, ranging in age from 1 month to 17 years. The extrapulmonary findings included cardiomegaly with right-sided cardiac enlargement, which was seen in 13 children. The central pulmonary arteries were enlarged in 15 children, with peripheral enlargement in two. In six children this resulted in bronchial compression. In addition, mediastinal and hilar lymphadenopathy was noted in three children. Prominent intrapulmonary features included a peripheral vasculopathy, with enlarged tortuous vessels, seen in eight children. Ill-defined ground-glass centrilobular opacities were also noted in eight children, representing the most common parenchymal abnormality. Other findings included septal lines in five, diffuse ground-glass opacification in four and focal hyperlucent zones in three. Mosaic attenuation was seen in one child. A variety of imaging findings are identified in IPAH. Features particularly consistent with the diagnosis include peripheral vasculopathy and centrilobular opacities in the setting of cardiomegaly and central pulmonary arterial enlargement. (orig.)

  4. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  5. Quantifying the usefulness of CT in evaluating seniors with abdominal pain

    International Nuclear Information System (INIS)

    Lewis, Lawrence M.; Klippel, Allen P.; Bavolek, Rebecca A.; Ross, Laura M.; Scherer, Tara M.; Banet, Gerald A.

    2007-01-01

    Objectives: (1) Determine if older patients with abdominal pain who receive emergency department (ED) abdominal CT have changes in diagnosis and/or disposition more often than similar patients without CT; (2) compare physician confidence in diagnosis and disposition for patients with versus without CT; (3) document factors that most influence physician's decision to order abdominal CT in this population. Methods: ED patients 60 years of age or older, with acute non-traumatic abdominal pain were enrolled over a 6-week period. Physicians documented a preliminary and final ED diagnosis and disposition, along with pre- and post-evaluation confidence levels. Decision to order CT, along with clinical information most influencing that decision, was noted. Physician confidence levels and percent change in diagnosis and disposition were compared for patients with versus without CT. Results: One hundred and twenty-six patients comprised study sample. Abdominal CT rate was 59% (95%CI, 50-67%). CT was associated with an increased change in diagnosis (46%; 95%CI, 4-58% versus 29%; 95%CI, 16-42%), but no change in disposition between patients with versus without CT. Preliminary diagnostic confidence was lower for EPs who ordered a CT than for those who did not (p < 0.001). Patient history most influenced ordering CT, whereas prior lab/imaging results most influenced not ordering CT. Conclusion: Patients with CT had a change in diagnosis more often than those without. Preliminary diagnostic confidence was lower in CT group. Percent change in disposition did not differ between groups. Physicians most often ordered CT based on history and did not order CT when other diagnostic evaluation supported a specific diagnosis

  6. Nonspecific interstitial pneumonia: Histologic correlation with high-resolution CT in 29 patients

    Energy Technology Data Exchange (ETDEWEB)

    Sumikawa, Hiromitsu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan)], E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp; Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan); Ichikado, Kazuya [Division of Respiratory Medicine, Saiseikai Kumamoto Hospital, 5-3-1 Tikami, Kumamoto 861-4193 (Japan); Taniguchi, Hiroyuki; Kondoh, Yasuhiro [Department of Respiratory Medicine and Allergy, Tosei General Hospital, 160 Nishioiwake-cho, Seto City, Aichi (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine, 67 Asahi-machi, Kurume 830-0011 (Japan); Yanagawa, Masahiro; Inoue, Atsuo; Mihara, Naoki; Honda, Osamu; Tomiyama, Noriyuki; Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan); Colby, Thomas V. [Department of Pathology, Mayo Clinic, Scottsdale, AZ (United States)

    2009-04-15

    Purpose: To determine the pathological correlation with various high-resolution CT (HRCT) findings in cases with nonspecific interstitial pneumonia (NSIP), paying special attention to pathological subgroups. Material and methods: The study involved 29 patients diagnosed with NSIP by surgical lung biopsy. A total of 54 specimens were obtained and grouped according to Katzenstein's classification (groups 1-3) for NSIP. Two observers then evaluated the HRCT findings for every biopsy site and classified the findings according to the main pattern evident into the following four radiologic pattern groups: A, ground-glass attenuation and fine reticulation; B, ground-glass and coarse reticulation; C, consolidation and D, ground-glass attenuation and consolidation. Results: The pathological pattern was NSIP group 1 in 6 patients, group 2 in 22 and group 3 in 25, while 1 specimen was normal. The main HRCT pattern was pattern A in 15 specimens, B in 8, C in 9 and D in 21. Although there were no significant correlation between HRCT patterns and histological subgroups (Chi-square test, p = 0.07), pattern C was more frequently seen in group 2 (7 of 9) and pattern A was more common in group 3 (11 of 15). HRCT pattern A corresponded pathologically to areas of thickened alveolar septa with temporal uniformity. Pattern B correlated with areas with airspace enlargement/emphysema or dilation of small airways superimposed on thickened alveolar septa. Pattern C was pathologically associated with areas of severe thickened alveolar septa, mucin stasis in the small airways and intraluminal organization. Conclusion: The pathological backgrounds of the same CT findings in patients with NSIP varied among all pathological subgroups. Areas of ground-glass attenuation and air-space consolidation did not always correspond to reversible pathological findings.

  7. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  8. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  9. PET/CT imaging in response evaluation of patients with small cell lung cancer

    DEFF Research Database (Denmark)

    Fischer, Barbara M; Mortensen, Jann; Langer, Seppo W

    2006-01-01

    UNLABELLED: There is an increasing amount of evidence on the usability of PET in response evaluation of non-small cell lung cancer. However, data on SCLC is scarce and mainly retrospective. This prospective study assesses the use of PET (positron emission tomography) and PET/CT in response...... evaluation of patients with small cell lung cancer (SCLC). METHODS: Assignment of early and final response was compared between PET, PET/CT, and CT in 20 patients with SCLC. Final response as assigned by CT (RECIST) served as reference. RESULTS: At response evaluation after one cycle of chemotherapy major...... by PET/CT is feasible, but it is uncertain whether it adds further information to evaluation by RECIST, thus further studies and standardization of methods are needed....

  10. FDG-PET/CT in the evaluation of anal carcinoma

    International Nuclear Information System (INIS)

    Cotter, Shane E.; Grigsby, Perry W.; Siegel, Barry A.

    2006-01-01

    Purpose: Surgical staging and treatment of anal carcinoma has been replaced by noninvasive staging studies and combined modality therapy. In this study, we compare computed tomography (CT) and physical examination to [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) in the staging of carcinoma of the anal canal, with special emphasis on determination of spread to inguinal lymph nodes. Methods and Materials: Between July 2003 and July 2005, 41 consecutive patients with biopsy-proved anal carcinoma underwent a complete staging evaluation including physical examination, CT, and 2-FDG-PET/CT. Patients ranged in age from 30 to 89 years. Nine men were HIV-positive. Treatment was with standard Nigro regimen. Results: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) detected 91% of nonexcised primary tumors, whereas CT visualized 59%. FDG-PET/CT detected abnormal uptake in pelvic nodes of 5 patients with normal pelvic CT scans. FDG-PET/CT detected abnormal nodes in 20% of groins that were normal by CT, and in 23% without abnormality on physical examination. Furthermore, 17% of groins negative by both CT and physical examination showed abnormal uptake on FDG-PET/CT. HIV-positive patients had an increased frequency of PET-positive lymph nodes. Conclusion: [ 18 F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography detects the primary tumor more often than CT. FDG-PET/CT detects substantially more abnormal inguinal lymph nodes than are identified by standard clinical staging with CT and physical examination

  11. Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact. Evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Nishiura, Motoko; Johkoh, Takeshi; Yamamoto, Shuji

    2007-01-01

    The aim of this study was to evaluate the decreasing of cardiac motion artifact and whether the extent of ground-glass attenuation of idiopathic pulmonary fibrosis (IPF) was accurately assessed by electrocardiography (ECG)-triggered high-resolution computed tomography (HRCT) by 0.5-s/rotation multidetector-row CT (MDCT). ECG-triggered HRCT were scanned at the end-diastolic phase by a MDCT scanner with the following scan parameters; axial four-slice mode, 0.5 mm collimation, 0.5-s/rotation, 120 kVp, 200 mA/rotation, high-frequency algorithm, and half reconstruction. In 42 patients with IPF, both conventional HRCT (ECG gating (-), full reconstruction) and ECG-triggered HRCT were performed at the same levels (10-mm intervals) with the above scan parameters. The correlation between percent diffusion of carbon monoxide of the lung (%DLCO) and the mean extent of ground-glass attenuation on both conventional HRCT and ECG-triggered HRCT was evaluated with the Spearman rank correlation coefficient test. The correlation between %DLCO and the mean extent of ground-glass attenuation on ECG-triggered HRCT (observer A: r=-0.790, P<0.0001; observer B: r=-0.710, P<0.0001) was superior to that on conventional HRCT (observer A: r=-0.395, P<0.05; observer B: r=-0.577, P=0.002) for both observers. ECG-triggered HRCT by 0.5 s/rotation MDCT can reduce the cardiac motion artifact and is useful for evaluating the extent of ground-glass attenuation of IPF. (author)

  12. Labyrinthine otosclerosis studied by high-resolution CT

    International Nuclear Information System (INIS)

    Funai, Hiroaki; Horiuchi, Yasuharu; Yano, Jun; Ushijima, Tatujiro; Iinuma, Toshitaka; Oyama, Kazuyuki

    1986-01-01

    Labyrinthine lesions of 10 patients (20 ears) with surgically confirmed otosclerosis were investigated by means of high-resolution CT (HRCT). All ears were scaned in horizontal plane and a slice thickness of 2.0 mm was used to avoid the excessive loss of sharpness by partial volume averaging. HRCTs of 14 normal ears and 18 ears with otitis media were analyzed as controls. (1) Three patients (6 ears) demonstrated lucent zones around the cochleae. In one of 3 cases the zone extended to involve the vestibule and the semicircular canals. (2) The definitive lucent zone was not observed in the control scans. (3) The clinical data of the 3 patients whose HRCTs demonstrated the lucent zones were compared with the other 7 patients with clinical otosclerosis. Three patients showed no distinctive features regarding to age, sex, Schwartze sign and the operative findings. (4) Average bone conduction loss was significantly greater in ears with lucent zones than those without the lucent zones. Serial audiograms revealed progressive hearing impairment in 3 ears of 2 patients with the definitive lucent zone. The present report confirmed that foci of demineralization (otospongiotic lesion) in the labyrinthine capsule were imaged by the HRCT as lucent areas. HRCT provides a reproducible and reliable mean of diagnosis for the labyrinthine otosclerosis. (author)

  13. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT

    International Nuclear Information System (INIS)

    Gervaise, Alban; Osemont, Benoit; Lecocq, Sophie; Blum, Alain; Noel, Alain; Micard, Emilien; Felblinger, Jacques

    2012-01-01

    To evaluate the impact of Adaptive Iterative Dose Reduction (AIDR) on image quality and radiation dose in phantom and patient studies. A phantom was examined in volumetric mode on a 320-detector CT at different tube currents from 25 to 550 mAs. CT images were reconstructed with AIDR and with Filtered Back Projection (FBP) reconstruction algorithm. Image noise, Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR) and spatial resolution were compared between FBP and AIDR images. AIDR was then tested on 15 CT examinations of the lumbar spine in a prospective study. Again, FBP and AIDR images were compared. Image noise and SNR were analysed using a Wilcoxon signed-rank test. In the phantom, spatial resolution assessment showed no significant difference between FBP and AIDR reconstructions. Image noise was lower with AIDR than with FBP images with a mean reduction of 40%. CNR and SNR were also improved with AIDR. In patients, quantitative and subjective evaluation showed that image noise was significantly lower with AIDR than with FBP. SNR was also greater with AIDR than with FBP. Compared to traditional FBP reconstruction techniques, AIDR significantly improves image quality and has the potential to decrease radiation dose. (orig.)

  14. Fever of unknown origin: A value of {sup 18}F-FDG-PET/CT with integrated full diagnostic isotropic CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiri [Department of Nuclear Medicine, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic); Radiodiagnostic Clinic, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic)], E-mail: ferda@fnplzen.cz; Ferdova, Eva [Department of Nuclear Medicine, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic); Radiodiagnostic Clinic, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic); Zahlava, Jan [Department of Nuclear Medicine, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic); Matejovic, Martin [Ist Internal Department, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic); Kreuzberg, Boris [Radiodiagnostic Clinic, Charles University Medical School and Teaching Hospital, Plzen (Czech Republic)

    2010-03-15

    Aim: The aim of presented work is to evaluate the clinical value of {sup 18}F-FDG-PET/CT in patients with fever of unknown origin (FUO) and to compare PET/CT finding with the results of the following investigation. Material and method: 48 patients (24 men, 24 women, mean age 57.6 years with range 15-89 years) underwent {sup 18}F-FDG-PET/CT due to the fever of unknown origin. All examinations were performed using complex PET/CT protocol combined PET and whole diagnostic contrast enhanced CT with sub-millimeter spatial resolution (except patient with history of iodine hypersensitivity or sever renal impairment). CT data contained diagnostic images reconstructed with soft tissue and high-resolution algorithm. PET/CT finding were compared with results of biopsies, immunology, microbiology or autopsy. Results: The cause of FUO was explained according to the PET/CT findings and followed investigations in 44 of 48 cases-18 cases of microbial infections, nine cases of autoimmune inflammations, four cases of non-infectious granulomatous diseases, eight cases of malignancies and five cases of proved immunity disorders were found. In 46 cases, the PET/CT interpretation was correct. Only in one case, the cause was overlooked and the uptake in atherosclerotic changes of arteries was misinterpreted as vasculitis in the other. The reached sensitivity was 97% (43/44), and specificity 75% (3/4) respectively. Conclusion: In patients with fever of unknown origin, {sup 18}F-FDG-PET/CT might enable the detection of its cause.

  15. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  16. Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaemena, Andreas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)], E-mail: andreas.kaemena@charite.de; Streitparth, Florian; Grieser, Christian; Lehmkuhl, Lukas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany); Jamil, Basil [Department of Radiotherapy, Charite-Medical University Berlin, Schumannstr. 20/21, D-10117 Berlin (Germany); Wojtal, Katarzyna; Ricke, Jens; Pech, Maciej [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)

    2007-10-15

    Purpose: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. Material and methods: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7 s, two adjacent 10 mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4 s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. Results: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1 s. Conclusion: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.

  17. High-resolution dynamic imaging and quantitative analysis of lung cancer xenografts in nude mice using clinical PET/CT.

    Science.gov (United States)

    Wang, Ying Yi; Wang, Kai; Xu, Zuo Yu; Song, Yan; Wang, Chu Nan; Zhang, Chong Qing; Sun, Xi Lin; Shen, Bao Zhong

    2017-08-08

    Considering the general application of dedicated small-animal positron emission tomography/computed tomography is limited, an acceptable alternative in many situations might be clinical PET/CT. To estimate the feasibility of using clinical PET/CT with [F-18]-fluoro-2-deoxy-D-glucose for high-resolution dynamic imaging and quantitative analysis of cancer xenografts in nude mice. Dynamic clinical PET/CT scans were performed on xenografts for 60 min after injection with [F-18]-fluoro-2-deoxy-D-glucose. Scans were reconstructed with or without SharpIR method in two phases. And mice were sacrificed to extracting major organs and tumors, using ex vivo γ-counting as a reference. Strikingly, we observed that the image quality and the correlation between the all quantitive data from clinical PET/CT and the ex vivo counting was better with the SharpIR reconstructions than without. Our data demonstrate that clinical PET/CT scanner with SharpIR reconstruction is a valuable tool for imaging small animals in preclinical cancer research, offering dynamic imaging parameters, good image quality and accurate data quatification.

  18. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  19. Evaluation of solitary pulmonary nodules by integrated PET/CT: improved accuracy by FDG uptake pattern and CT findings

    International Nuclear Information System (INIS)

    Joon Young Choi; Kyung Soo Lee; O Jung Kwon; Young Mog Shim; Kyung-Han Lee; Yong Choi; Yearn Seong Choe; Byung-Tae Kim

    2004-01-01

    Objective: FDG PET is useful to differentiate malignancy from benign lesions in the evaluation of solitary pulmonary nodules (SPNs). However, FDG PET showed false positive results in benign inflammatory lesions such as tuberculosis and organizing pneumonia. Furthermore, malignant tumors such as adenocarcinoma (AC) with bronchioloalveolar carcinoma (BAC) type had lower FDG uptake than other cell types of non-small cell lung cancer. We investigated whether FDG uptake pattern and image findings of CT for attenuation correction could improve accuracy for evaluating SPNs over SUV in integrated PET/CT imaging using FDG. Methods: Forty patients (M:F = 23:17, mean age 58.2±9.4 yrs) with non-calcified SPNs (diameter on CT 30 mm, no significant mediastinal node enlargement, no atelectasis) were included. All subjects underwent integrated PET/CT imaging using FDG. One nuclear medicine physician and 1 chest radiologist interpreted the PET and non-contrast CT images for attenuation correction, respectively. On PET images, maximum SUV of SPN was acquired, and FDG uptake pattern was categorized as diffusely increased or heterogeneously increased with upper threshold of window setting adjusted to maximum SUV of each nodule. A radiologist interpreted SPNs as benign or malignant based on CT images with lung and mediastinai window settings blinded to PET findings. Results: On pathological exam, 30 SPNs were confirmed to be malignant (11 AC with non-BAC type, 8 AC with BAC type, 8 squamous cell carcinoma, 1 adenosquamous cell carcinoma, 1 neuroendocrine carcinoma, 1 large cell carcinoma), and 10 were benign (4 tuberculosis, 3 organizing pneumonia, 2 sclerosing pneumocytoma, 1 non-specific inflammation). All 5 nodules with max SUV 7.0 except one with tuberculoma had malignancy. When only nodules with diffusely increased uptake were considered malignant in indeterminate group with max SUV of 4.0 to 7.0, PET could diagnose 5 of 9 malignant nodules with one false positive nodule. In 6 of

  20. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  1. CT evaluation of severe renal inflammatory disease in children

    International Nuclear Information System (INIS)

    Montgomery, P.; Kuhn, J.P.; Afshani, E.

    1987-01-01

    We have performed CT scans on 15 children and 2 young adults with severe renal inflammatory disease. Most children with urinary tract infections do not require such evaluation. We have, however, found CT helpful in defining the nature of renal abnormality and in defining the extent of disease in selected patients who either presented as diagnostic dilemmas or who did not respond initially to proper medical treatment. We therefore use CT scanning as our initial examination in such problem patients. (orig.)

  2. Rare case of Primary Pulmonary Extranodal Non-Hodgkin’s Lymphoma in a Patient with Sjogrens Syndrome: Role of FDG-PET/CT in the Initial Staging and Evaluating Response to Treatment

    Directory of Open Access Journals (Sweden)

    Gonca G. Bural

    2012-12-01

    Full Text Available A 64-year old woman with a long standing Sjogren’s syndrome was undergoing evaluation for renal transplant surgery when two pulmonary opacities were detected on chest CT. Subsequent biopsy revealed extranodal marginal B-cell non-Hodgkin’s lymphoma (NHL. An FDG-PET/CT scan was then performed which demonstrated isolated FDG avid pulmonary involvement. After therapy, FDG-PET/CT scans showed good response to treatment with near complete resolution of FDG avidity. This rare case illustrates the rare pulmonary manifestation of extranodal lymphoma in a patient with Sjogren’s syndrome and emphasizes the value of FDG PET/CT in the initial staging and evaluation of response to treatment, which has not previously been published. (MIRT 2012;21:117-120

  3. Atheromatous extracranial carotid arteries: CT evaluation correlated with arteriography and pathologic examination

    International Nuclear Information System (INIS)

    Leeson, M.D.; Cacayorin, E.D.; Iliya, A.R.; Hodge, C.J.; Culebras, A.; Collins, G.H.; Kieffer, S.A.

    1985-01-01

    Dynamic, rapid sequence, axial computed tomography (CT) was employed to evaluate the extracranial common and internal carotid arteries in 17 patients with clinical histories suggesting recent or remote ischemia in the territory supplied by the internal carotid artery. The CT findings were correlated with arteriographic observations and with gross and histologic evaluations of endarterectomy specimens. Areas of arterial wall thickening were evaluated on CT scans with regard to both degree of thickening and radiographic density (attenuation). The degree of vessel wall thickening secondary to atheromatous plaque demonstrated on CT scans corresponded closely to the severity of luminal compromise seen on arteriograms. While arteriography provides information regarding the status of the arterial lumen, CT offers the potential of accurate characterization of pathologic changes in the wall of the extracranial carotid arteries in patients with symptoms of cerebral ischemia

  4. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  5. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  6. Ultra-high-resolution C-arm flat-detector CT angiography evaluation reveals 3-fold higher association rate for sporadic intracranial cavernous malformations and developmental venous anomalies: a retrospective study in consecutive 58 patients with 60 cavernous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kocak, Burak [Aksaray State Hospital, Department of Radiology, Aksaray (Turkey); Kizilkilic, Osman; Kocer, Naci; Islak, Civan [Istanbul University, Department of Radiology, Cerrahpasa Medical Faculty, Istanbul (Turkey); Oz, Buge; Bakkaloglu, Dogu Vuralli [Istanbul University, Department of Pathology, Cerrahpasa Medical Faculty, Istanbul (Turkey); Isler, Cihan [Istanbul University, Department of Neurosurgery, Cerrahpasa Medical Faculty, Istanbul (Turkey)

    2017-06-15

    The imaging and surgical literature has confusing association rates for the association between sporadic intracranial cavernous malformations (CMs) and developmental venous anomalies (DVAs). In this study, our purpose was to determine the association rate using ultra-high-resolution C-arm flat-detector CT angiography (FDCTA) and compare it with literature. Fifty-eight patients with 60 sporadic intracranial CMs that underwent an FDCTA study were included in our retrospective study. Re-evaluation of radiological data was performed based on the criteria defined by authors. Isotropic volumetric reconstructions with ultra-high resolution (voxel size of 102 μm{sup 3} for initial; 67 μm{sup 3} and 32 μm{sup 3} for further evaluation) were used for assessment. Sixteen patients underwent surgery for excision of their CMs. Fifty-one of all patients (87.9 %) were associated with a DVA. Undefined local venous structures (UD-LVSs) were observed in the remaining 7 patients (12.1 %). The strength of interobserver agreement was excellent [kappa(k) coefficient = 0.923]. Ultra-high-resolution FDCTA evaluation of CMs and DVAs reveals 3-fold higher association rate compared to the literature. FDCTA for patients with sporadic CMs could help identify the associated DVAs that remained undetected or unclear with other imaging modalities, which can be useful in decision-making processes, planning surgery, and during operation. (orig.)

  7. Evaluation of anemia on unenhanced CT of the thorax

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Zhang Xuelin; Zhong Qun; Zhang Fan; Zhang Wensheng

    2006-01-01

    Objective: To explore the correlation between CT density of blood in Cardiac Chambers and hemoglobin concentration in blood, and to evaluate the veracity of diagnosis of aneamia on unenhanced computed tomography of the thorax. Methods: Thorax (heart) helical CT was performed in 92 patients. In each case, the CT values of the blood pool in left ventricle and ventricular septum were tested, and the ratio of blood pool/ventricular septum were calculated. The hemoglobin concentration in blood was tested. The correlation among these indexes were analysed. Results: In these factors, CT density of blood was strongly and positively correlated with hemoglobin concentration in blood (r=0.571, P=0.000), and the CT density ratio was also strongly and positively correlated with hemoglobin concentration in blood (r=0.650, P=0.000). It dramatically implies that the patient may be suffering from aneamia when the ratio is Ness than 90% (male) or 87% (female). Conclusion: Blood pool/ventricular septum CT density ratio may be as a reliable indicator for judging and grading aneamia with CT. (authors)

  8. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  9. Pulmonary Lipiodol Accumulation after Transarterial Chemoembolization: CT Findings and Its Radiologic Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Young; Chong, Se Min; Kwak, Byung Kook; Shin, Hyung Jin; Seo, Gi Young; Seo, Jae Seung; Kim, Jae Kyun [Dept. of Radiology, Chung Ang University Medical Center, Chung Ang University College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    To evaluate CT findings and radiologic outcomes of pulmonary lipiodol accumulation (PLA) after transarterial chemoembolization (TACE). This retrospective study involved 488 TACEs for hepatocellular carcinoma (HCC) (n = 160) and hepatic metastasis for non-hepatic malignancies (n = 7) in 167 patients. We reviewed the patient clinicoradiologic findings before and after TACE and calculated the incidence of PLA and PLA resolution time after initial CT and after TACE. Lipiodol accumulation in the lungs was seen under CT after TACE in seven patients (M : F = 6 : 1, mean age 61 years). The incidence of PLA at CT was 4.1% (7/167 patients). In five patients, associated intrathoracic abnormalities including pleural effusion with (n 3) or without consolidation (n = 2) were revealed at CT scans. The CT resolution time and PLA recovery time were 56 {+-} 54 days and 66 {+-} 52 days, respectively. The recovery time for lipiodol accumulation was 66 days. It is believed that the clinical and radiologic outcome of PLA without respiratory failure is promising, and conservative treatment will suffice when lipiodol accumulation in the lungs is seen in CT images after TACE.

  10. Phantom study for the systemic performance of Gemini PET/CT

    International Nuclear Information System (INIS)

    Feng Yanlin; He Xiaohong; Huang Kemin; Yu Fengwen; Liu Dejun; Yuan Jianwei; Yuan Baihong; Su Shaodi

    2005-01-01

    Objective: To develop the methods and parameters for evaluating the systemic performance of Gemini PET/CT. Methods: The spatial resolution, standardized uptake value (SUV), uniformity and accuracy of image registration were selected as the evaluating indexes. The Jaszczak phantom with smaller inserts was filled with 18 F-fluorodeoxyglucose (FDG) solution and imaged with whole body and brain imaging modes, respectively, to evaluate the spatial resolution of the PET/CT; a Philips hollow phantom was filled with 18 F-FDG solution and imaged for calculating the SUV and the uniformity parameters; four 22 Na solid sources were put under the pad of the patient table and imaged synchronously with the patient's data acquisition to evaluate the accuracy of the PET and CT image fusion. Results: The rods of the diameter of 6.4 mm of both the hot and cold inserts were observed with whole body imaging mode, and rods of the diameters of 4.8 mm of both the hot and cold inserts were observed with brain imaging mode. The SUV with X-ray CT attenuation correction (CTAC) was 0.92 ± 0.24, and was 0.99±0.26 with 137 Cs attenuation correction (CsAC), and t=-1.327, P>0.05 between the two groups. The uniformity of the images with both CTAC and CsAC was very nice, no artifacts were seen either. The maximum pixel counts was 3790, the minimum was 1434, the average was 2581.23 and the standard deviation was 728.39 with CTAC; and were 4218, 1073, 2758.19 and 838.79 with CsAC correspondingly, and t=-1.069, P>0.05 between the two groups. The images of PET and CT were registrated better, and also no diversity was detected on the fusion images. Conclusions: These methods and parameters might be used to evaluate the systemic performance of the PET/CT, and could also be used as the supplementary items for the acceptance test and daily quality assurance of the PET/CT. (authors)

  11. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images

    International Nuclear Information System (INIS)

    Park, Sang-June; Ionascu, Dan; Killoran, Joseph; Chin, Lee; Berbeco, Ross; Mamede, Marcelo; Gerbaudo, Victor H

    2008-01-01

    Gated (4D) PET/CT has the potential to greatly improve the accuracy of radiotherapy at treatment sites where internal organ motion is significant. However, the best methodology for applying 4D-PET/CT to target definition is not currently well established. With the goal of better understanding how to best apply 4D information to radiotherapy, initial studies were performed to investigate the effect of target size, respiratory motion and target-to-background activity concentration ratio (TBR) on 3D (ungated) and 4D PET images. Using a PET/CT scanner with 4D or gating capability, a full 3D-PET scan corrected with a 3D attenuation map from 3D-CT scan and a respiratory gated (4D) PET scan corrected with corresponding attenuation maps from 4D-CT were performed by imaging spherical targets (0.5-26.5 mL) filled with 18 F-FDG in a dynamic thorax phantom and NEMA IEC body phantom at different TBRs (infinite, 8 and 4). To simulate respiratory motion, the phantoms were driven sinusoidally in the superior-inferior direction with amplitudes of 0, 1 and 2 cm and a period of 4.5 s. Recovery coefficients were determined on PET images. In addition, gating methods using different numbers of gating bins (1-20 bins) were evaluated with image noise and temporal resolution. For evaluation, volume recovery coefficient, signal-to-noise ratio and contrast-to-noise ratio were calculated as a function of the number of gating bins. Moreover, the optimum thresholds which give accurate moving target volumes were obtained for 3D and 4D images. The partial volume effect and signal loss in the 3D-PET images due to the limited PET resolution and the respiratory motion, respectively were measured. The results show that signal loss depends on both the amplitude and pattern of respiratory motion. However, the 4D-PET successfully recovers most of the loss induced by the respiratory motion. The 5-bin gating method gives the best temporal resolution with acceptable image noise. The results based on the 4D

  12. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  13. Preoperative CT evaluation on nasal cavity for transsphenoidal approach

    International Nuclear Information System (INIS)

    Saeki, Naokatsu; Yamaura, Akira; Hoshi, Seiichiro; Sunada, Souichi; Sunami, Kenro

    1997-01-01

    Preoperative bone CT scans sliced parallel to the surgical plane were evaluated in 32 cases of transsphenoidal surgery. This method predicted patients with narrow nasal cavity, and helped to determine the rhinological maneuvers for providing a wider operative field. In addition, it helps to plan the need and extent of sella floor removal in re-operated cases. There was relatively little difference in the width and length of the nasal cavity between acromegalic and non-acromegalic patients. Hence, bone CT scans are useful in the preoperative evaluation of patients undergoing transsphenoidal surgery. (author)

  14. Philips Gemini TF64 PET/CT Acceptance Testing

    International Nuclear Information System (INIS)

    González Gonzalez, Joaquín J.; Calderón Marin, Carlos F.; Varela Corona, Consuelo; Machado Tejeda, Adalberto; González Correa, Héctor J.

    2016-01-01

    The Philips Gemini TF64 is the first PET/CT scanner installed in Cuba at the Institute of Oncology and Radiobiology in 2014. It is a third generation fully tridimensional whole body PET scanner with time-of-flight (TOF) technology combined with a 64-slice Brilliance CT scanner. The CT detector module contains 672x64 solid state detector, incorporating GOS scintillators, optical diodes and electronic signal channels arranged in 64 side by side arcs, with 672 detectors in each arc. There are sixteen 0.75 mm individual detector elements around the center and four 1.5 mm elements at each end, resulting in a 24 mm total detection length. The PET detector consists of 28 pixelar modules of a 23x44 array of 4x4x22 mm3 of LYSO crystals arranged in an Anger-logic detector design. The hardware coincidence-timing window for this scanner is set at 4 ns and delayed coincidence window technique is used to estimate the random coincidences in collected data. In this study the performance characteristics of PET/CT scanner were measured as part of the program tests of acceptance for clinical use.Methodology. The performance characteristics of CT scanner were evaluated by manufacturer protocol using Philips system performance phantom. Some additional geometrical tests were performed by the user. The intrinsic measurements of energy resolution as well as timing resolution, which define the TOF performance of PET scanner, were performed following the recommendations of manufacturer using 18 F. Spatial resolution, sensitivity, scatter fraction, counting rate performance, image quality and accuracy were measured according to the NEMA NU-2 2007 procedures. Additionally, to characterize the effect of TOF reconstruction on lesion contrast and noise, the standard NEMA torso phantom was reconstructed with and without TOF capability. The accuracy of PET/CT image registration was tested according to the manufacturer protocol using an image alignment calibration holder with 6 point sources of 22

  15. 4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

    Science.gov (United States)

    Min, Yugang; Neylon, John; Shah, Amish; Meeks, Sanford; Lee, Percy; Kupelian, Patrick; Santhanam, Anand P

    2014-09-01

    The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations. The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range. Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism. The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

  16. Ranking of CT in persistent vertigo after implantation of stapes prostheses

    International Nuclear Information System (INIS)

    Koesling, S.; Woldag, K.; Meister, E.F.; Reschke, I.; Schulz, H.G.

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [de

  17. 18FFDG PET in evaluating malignancies compared with CT, MRI and pathology in 58 cases

    International Nuclear Information System (INIS)

    Li, L.

    2000-01-01

    This article discussed the practical application of 18 F-FDG PET imaging techniques to depict, state, or define recurrences for five important malignancies: lung cancer, colorectal and head-and-neck cancer, intracranial malignant glioma and primary or secondary hepatic malignant diseases. And comparisons of 18 F-FDG PET with CT, MRI imaging were addressed specifically. We reviewed our initial experience with 48 malignant and ten non-malignant cases. Among malignant group, 36 cases were confirmed by operation or biopsy, Other ten non-malignant diseases, including brain infarction, post-radiotherapy necrosis or scar and lung abscesses were followed with CT or MRI at least 6 months. All patients received intravenous administration of 18 F-FDG 10-15 mCi, followed by a 40 minutes uptake phase, and subsequent imaged using a Siemens ECAT 931 whole-body scanner with resolution of 4 mm FWHM in the center of the field of view. Filtered back projection reconstruction was used to display attenuated or non-attenuated corrected images. The result of 18 F-FDG PET was retrospectively evaluated to assess the degree of uptake of 18 F-FDG PET in the tumor tissues and compared with CT, MRI and pathology. CT and MRI exam were taken before or after PET study in two weeks. 18 F-FDG PET scans showed a significantly increased FDG metabolism in 47 malignant lesions, The tumor / normal tissue FDG uptake rate were 4.16 ±2.11. In 47 cases with neoplasm, 18 F-FDG PET findings were constant with or further confirmed the CT or MRI diagnosis in 35/47 (74.5%) and 12/47 (253%) cases. Another one small intracranial metastasis ( 18 F-FDG PET imaging in oncology has demonstrated powerful advantage in characterizing tumor lesions, differentiating recurrent disease from treatment effects, staging tumors, evaluating the extent of disease, and monitoring therapy. But 18 F-FDG PET still cant replace CT or MRI in malignance diagnosis. It will be used to approach and hopefully answer the difficult diagnosis

  18. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  19. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    International Nuclear Information System (INIS)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques; Santangelo, Teresa; Duhamel, Alain; Deschildre, Antoine

    2017-01-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol 32 ) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP 32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP 32 , CTDI vol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP 32 , 0.78-1.25 mGy for the CTDI vol32 and 1.6-2.1 mGy for the SSDE. (orig.)

  20. Effect of CT image size and resolution on the accuracy of rock property estimates

    Science.gov (United States)

    Bazaikin, Y.; Gurevich, B.; Iglauer, S.; Khachkova, T.; Kolyukhin, D.; Lebedev, M.; Lisitsa, V.; Reshetova, G.

    2017-05-01

    In order to study the effect of the micro-CT scan resolution and size on the accuracy of upscaled digital rock property estimation of core samples Bentheimer sandstone images with the resolution varying from 0.9 μm to 24 μm are used. We statistically show that the correlation length of the pore-to-matrix distribution can be reliably determined for the images with the resolution finer than 9 voxels per correlation length and the representative volume for this property is about 153 correlation length. Similar resolution values for the statistically representative volume are also valid for the estimation of the total porosity, specific surface area, mean curvature, and topology of the pore space. Only the total porosity and the number of isolated pores are stably recovered, whereas geometry and the topological measures of the pore space are strongly affected by the resolution change. We also simulate fluid flow in the pore space and estimate permeability and tortuosity of the sample. The results demonstrate that the representative volume for the transport property calculation should be greater than 50 correlation lengths of pore-to-matrix distribution. On the other hand, permeability estimation based on the statistical analysis of equivalent realizations shows some weak influence of the resolution on the transport properties. The reason for this might be that the characteristic scale of the particular physical processes may affect the result stronger than the model (image) scale.

  1. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease.

    Science.gov (United States)

    Katsura, Masaki; Sato, Jiro; Akahane, Masaaki; Mise, Yoko; Sumida, Kaoru; Abe, Osamu

    2017-08-01

    To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). MBIR offered significantly lower objective image noise (22.24±4.53, PASIR (39.76±7.41) and FBP (51.91±9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (PASIR and FBP. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D); Untersuchungen zur Bildqualitaet, Hochkontrastaufloesung und Dosis am Stamm- und Gliedmassenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)

    Energy Technology Data Exchange (ETDEWEB)

    Rock, C.; Kotsianos, D.; Linsenmaier, U. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Klinische Radiologie; Fischer, T. [Klinikum der Universitaet Muenchen, Muenchen (DE). Inst. fuer Klinische Radiologie] (and others)

    2002-02-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [German] Zielsetzung: Evaluierung der 3D-CT-Bildgebung mit einem C-Bogen-basierten dedizierten CT-System (ISO-C-3D, Fa. Siemens) an Extremitaetengelenken und am Stammskelett. Methodik: 27 humane Leichenpraeparate der unteren und oberen Extremitaet sowie des Stammskeletts wurden am ISO-C-3D untersucht und die Bilddaten anhand eines Bildqualitaetsscores von 3 Untersuchern semiquantitativ evaluiert (Score 1: nicht

  3. Perpheral bronchopleural fistula: CT evaluation in 22 patients

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Min Young; Choi, Seong Hee; Kim, Eung Jo; Lee, Jin Joo; Kim, Oak

    1999-01-01

    To determine the usefulness of CT for the evaluation of peripheral bronchopleural fistulas. CT scans of 22 patients with persistent air leak, as seen on serial chest PA, and a clinical history, were retrospectively evaluated. We determined the visibility of direct communication between the lung and pleural space, and the frequency and location of this, and if direct communications were not visualized the probable cause. A bronchopleural fistula(n=13) or its probable cause(n=6) was visualized in 19 patients(86%). Direct communications between the lung and pleural space were seen in 13 patients(59%) ; there were six cases of tuberculous empyema, three of tuberculosis, two of necrotizing empyema, one of trauma, and one of postobstructive pneumonitis. In six patients, bronchiectatic change in peripheral lung adjacent to the pleural cavity was noted, and although this was seen as a probable cause of bronchopleural fistula, direct communication was invisible. Bronchopleural fistula or its probable cause was multiple in 18 of 19 patients, involving the upper and lower lobe in eight, the upper in nine, and the lower in two. CT is useful for evaluating the presence of bronchopleural fistula, and its frequency and location, and in patients in whom the fistula is not directly visualized, the cause of this

  4. CT and MR imaging in the evaluation of leptomeningeal metastases

    International Nuclear Information System (INIS)

    Xiao Jiahe; Wang Dayou; Deng Kaihong

    1999-01-01

    Objective: To study the manifestations of leptomeningeal metastases on CT and MR imaging, and evaluate the diagnostic significance of both modalities for this disease. Methods: Clinical and neuroradiological data of 21 cases with leptomeningeal metastases were retrospectively reviewed. In this series, 16 patients were studied by CT and 7 patients by MRI, 2 patients by both CT and MRI. Results: Abnormal enhancement of pia and subarachnoid space, appearing as diffuse pattern in 10 cases, nodular pattern in 8 cases and mixed pattern with diffuse plus nodules in 3 cases, were visualized by CE-CT and Gd-MRI. Diffuse enhancement followed the convolutions of gyri and surface of brainstem, and extended into cerebral cisterns and sulci. the foci appeared as enhanced nodules 0.2-3.0 cm in diameter and 1 or more in number. Nodules with infiltration of cerebral parenchymal were found in 4 patients. In 86% of all cases, diffuse or nodular foci occurred in basilar systems and adjacent cerebellar and cerebral sulci. There were 4 cases associated with ependymal nodular enhancement and 10 cases with widened irregular tentorial enhancement. Intracerebral metastases in 9 cases and hydrocephalus in 13 cases were found in this series. Conclusions: CE-CT and Gd-MRI are had significant clinical diagnostic value for leptomeningeal metastases, Gd-MRI is superior to CE-CT. Because of the limitation in the evaluation of leptomeningeal invasion by neoplasms on CT and MRI, definitive diagnosis of leptomeningeal metastases depends on combination of clinical and imaging data

  5. Comparison of plain radiography and CT in postoperative evaluation of ankle fractures

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, K.; Qiang, M.; Li, H.; Dai, H.

    2015-01-01

    Aim: To compare postoperative plain radiographs with computed tomography (CT) post-processing images in evaluating the quality of anatomical reduction and internal fixation of ankle fractures. Materials and methods: A total of 168 patients who sustained closed ankle fracture and were treated with open reduction and internal fixation in East Hospital were reviewed. Postoperative plain radiographs and CT post-processing images were evaluated. The observation was performed under volume-rendering mode and multiplanar reconstruction mode. The assessment was performed by two independent orthopaedic surgeons. The inter- and intra-observer variations were analysed by kappa statistics. The differences between plain radiographs and CT post-processing images were compared using χ 2 test (McNemar's test). Results: Inter- and intra-observer agreement was almost perfect (0.813–1.000) using CT post-processing images, which was higher than that using plain radiographs (0.323–0.848). More non-anatomical reduction could be recognised in the supination–external rotation (SER), supination–adduction (SAD), pronation–external rotation (PER), and overall groups (p<0.05) and more poor internal fixation could be recognised in the SER, SAD, and overall groups (p<0.05) using CT post-processing images than using radiographs. Conclusion: More residual articular step, fracture fragment displacement, and poor internal fixation could be detected by CT post-processing images than plain radiographs. -- Highlights: •We compared postoperative X-rays with CT images in ankle fractures. •The evaluation agreement using CT images was higher than X-rays. •CT images detect more residual articular steps than X-rays. •CT images detect more fracture fragment displacement than X-rays. •CT images detect more poor internal fixation than X-rays

  6. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  7. {sup 18}F{sub F}DG PET in evaluating malignancies compared with CT, MRI and pathology in 58 cases

    Energy Technology Data Exchange (ETDEWEB)

    Li, L. [Air Force General Hospital, Beijing (Switzerland)

    2000-07-01

    This article discussed the practical application of {sup 18}F-FDG PET imaging techniques to depict, state, or define recurrences for five important malignancies: lung cancer, colorectal and head-and-neck cancer, intracranial malignant glioma and primary or secondary hepatic malignant diseases. And comparisons of {sup 18}F-FDG PET with CT, MRI imaging were addressed specifically. We reviewed our initial experience with 48 malignant and ten non-malignant cases. Among malignant group, 36 cases were confirmed by operation or biopsy, Other ten non-malignant diseases, including brain infarction, post-radiotherapy necrosis or scar and lung abscesses were followed with CT or MRI at least 6 months. All patients received intravenous administration of {sup 18}F-FDG 10-15 mCi, followed by a 40 minutes uptake phase, and subsequent imaged using a Siemens ECAT 931 whole-body scanner with resolution of 4 mm FWHM in the center of the field of view. Filtered back projection reconstruction was used to display attenuated or non-attenuated corrected images. The result of {sup 18}F-FDG PET was retrospectively evaluated to assess the degree of uptake of {sup 18}F-FDG PET in the tumor tissues and compared with CT, MRI and pathology. CT and MRI exam were taken before or after PET study in two weeks. {sup 18}F-FDG PET scans showed a significantly increased FDG metabolism in 47 malignant lesions, The tumor / normal tissue FDG uptake rate were 4.16 {+-}2.11. In 47 cases with neoplasm, {sup 18}F-FDG PET findings were constant with or further confirmed the CT or MRI diagnosis in 35/47 (74.5%) and 12/47 (253%) cases. Another one small intracranial metastasis (<0,6cm), shown on contrast MRI was not displayed by glucose metabolism Otherwise, the tumor/normal tissue FDG uptake rate were 0.86 {+-} 1,46 in ten non-malignant cases. Most of post-radiotherapy cerebral necrosis, which can't be distinguished on both contrast CT and MRI, showed FDG uptake defect. One cerebral infarction, previously

  8. Interactively variable isotropic resolution in computed tomography

    International Nuclear Information System (INIS)

    Lapp, Robert M; Kyriakou, Yiannis; Kachelriess, Marc; Wilharm, Sylvia; Kalender, Willi A

    2008-01-01

    An individual balancing between spatial resolution and image noise is necessary to fulfil the diagnostic requirements in medical CT imaging. In order to change influencing parameters, such as reconstruction kernel or effective slice thickness, additional raw-data-dependent image reconstructions have to be performed. Therefore, the noise versus resolution trade-off is time consuming and not interactively applicable. Furthermore, isotropic resolution, expressed by an equivalent point spread function (PSF) in every spatial direction, is important for the undistorted visualization and quantitative evaluation of small structures independent of the viewing plane. Theoretically, isotropic resolution can be obtained by matching the in-plane and through-plane resolution with the aforementioned parameters. Practically, however, the user is not assisted in doing so by current reconstruction systems and therefore isotropic resolution is not commonly achieved, in particular not at the desired resolution level. In this paper, an integrated approach is presented for equalizing the in-plane and through-plane spatial resolution by image filtering. The required filter kernels are calculated from previously measured PSFs in x/y- and z-direction. The concepts derived are combined with a variable resolution filtering technique. Both approaches are independent of CT raw data and operate only on reconstructed images which allows for their application in real time. Thereby, the aim of interactively variable, isotropic resolution is achieved. Results were evaluated quantitatively by measuring PSFs and image noise, and qualitatively by comparing the images to direct reconstructions regarded as the gold standard. Filtered images matched direct reconstructions with arbitrary reconstruction kernels with standard deviations in difference images of typically between 1 and 17 HU. Isotropic resolution was achieved within 5% of the selected resolution level. Processing times of 20-100 ms per frame

  9. Evaluation of PET/CT combined with HRCT in differentiating malignant from benign solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ge Quanxu; Zhu Renjuan; Liu Qingwei; Lv Shouchen; Yao Shuzhan; Li Xin

    2005-01-01

    Objective: To investigate the clinical value of 18 F-fluorodeoxyglucose (FDG) PET/CT combined with high resolution CT (HRCT) to differentiate solitary pulmonary nodule (SPN). Methods: 25 patients with 27 SPN were examined with 18 F-FDG PET/CT and HRCT, all of them were proved pathologically or by follow-up. The differential diagnosis of SPN were made using visual method and semi-quantitative method on PET/CT and morphological characteristics on HRCT. The results of 18 F-FDG PET/CT and 18 F-FDG PET/CT combined with HRCT were compared with pathological results. Results: 15 were malignant and 12 benign among the 27 SPN. 14 SPN were positive on PET/CT among 15 malignant SPN with only one negative less than 10 mm in size. 3 benign were positive on PET/CT, but 2 of them were correctly diagnosed as benign by PET/CT combined with HRCT. The specificity, negative predictive value and accuracy of 18 F-FDG PET/CT combined with HRCT were higher than that of PET/CT (91.7%, 93.3%, 91.7% and 93.7% vs 75.0%, 82.4%, 90.0% and 85.2% ). The sensitivity of PET/CT combined with HRCT and PET/CT alone was same (93.3%). Conclusion: 18 F-FDG PET/CT combined with HRCT is a effective no-invasive method in differentiating malignant SPN from benign. (authors)

  10. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  11. CT diagnosis and differential diagnosis of otodystrophic lesions of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    D' Archambeau, O.; Parizel, P.M.; Schepper, A.M. De (Antwerp University Hospital (Belgium). Department of Radiology); Koekelkoren, E.; Van De Heyning, P. (Antwerp University Hospital (Belgium). Department of E.N.T.)

    The purpose of this study was to assess the diagnostic and differential diagnostic value of high-resolution computed tomography in the evaluation of temporal-bone dystrophies. The study group included 55 patients with osseous abnormalities of the temporal bone in general, and the labyrinthine capsule in particular. In 27 patients the CT scan revealed evidence of otodystrophic lesions. The CT findings in patients with otosclerosis (21 patients), osteogenesis imperfecta (two patients), fibrous dysplasia (one patient). Paget's disease (one patient) and osteoporosis (two patients) are described. The CT scans of 17 patients revealed secondary osseous lesions due to metastasis (five patients), post-inflammatory changes (10 patients) or labyrinthitis ossificans (two patients). Normal variants and congenital mineralization defects were diagnosed in nine patients, Down's syndrome in two. Our results indicate the importance of high-resolution computed tomography as the primary imaging modality in evaluating osseous lesions of the temporal bone and labyrinth. (author). 14 refs.; 13 figs; 2 tabs.

  12. CT diagnosis and differential diagnosis of otodystrophic lesions of the temporal bone

    International Nuclear Information System (INIS)

    D'Archambeau, O.; Parizel, P.M.; Schepper, A.M. De; Koekelkoren, E.; Van De Heyning, P.

    1990-01-01

    The purpose of this study was to assess the diagnostic and differential diagnostic value of high-resolution computed tomography in the evaluation of temporal-bone dystrophies. The study group included 55 patients with osseous abnormalities of the temporal bone in general, and the labyrinthine capsule in particular. In 27 patients the CT scan revealed evidence of otodystrophic lesions. The CT findings in patients with otosclerosis (21 patients), osteogenesis imperfecta (two patients), fibrous dysplasia (one patient). Paget's disease (one patient) and osteoporosis (two patients) are described. The CT scans of 17 patients revealed secondary osseous lesions due to metastasis (five patients), post-inflammatory changes (10 patients) or labyrinthitis ossificans (two patients). Normal variants and congenital mineralization defects were diagnosed in nine patients, Down's syndrome in two. Our results indicate the importance of high-resolution computed tomography as the primary imaging modality in evaluating osseous lesions of the temporal bone and labyrinth. (author). 14 refs.; 13 figs; 2 tabs

  13. High resolution spiral CT for determining the malignant potential of solitary pulmonary nodules: refining and testing the test

    Energy Technology Data Exchange (ETDEWEB)

    Harders, Stefan Walbom; Madsen, Hans Henrik; Rasmussen, Finn (Dept. of Radiology, Aarhus Univ. Hospital, Aarhus (Denmark)), Email: stefhard@rm.dk; Rasmussen, Torben Riis (Dept. of Pulmonology, Aarhus Univ. Hospital, Aarhus (Denmark)); Hager, Henrik (Dept. of Pathology, Aarhus Univ. Hospital, Aarhus (Denmark))

    2011-05-15

    Background A solitary pulmonary nodule (SPN) may represent early stage lung cancer. Lung cancer is a devastating disease with an overall 5-year mortality rate of approximately 84% but with early detection and surgery as low as 47%. Currently a contrast-enhanced multiple-row detector CT (MDCT) scan is the first examination when evaluating patients with suspected lung cancer. Purpose To apply an additional high resolution CT (HRCT) to SPNs to test whether certain morphological characteristics are associated with malignancy, to assess the diagnostic accuracy of HRCT in the characterization of SPNs, and to address the reproducibility of all measures. Material and Method Two hundred and thirteen participants with SPNs were included in a follow-up study. Blinded HRCT images were assessed with regard to margin risk categories (MRCs), calcification patterns and certain other characteristics and overall malignancy potential ratings (MPRs) were given. Morphological characteristics were tested against reference standard and ROC methodology was applied to assess diagnostic accuracy. Reproducibility was measured with Kappa statistics and 95% confidence intervals were computed for all results. Histopathology (90%) and CT follow-up (10%) were used as reference standard. Results MRCs (P < 0.001), calcification patterns (P = 0.003), and pleural retraction (P < 0.001) were all statistically significantly associated to malignancy. Reproducibility was moderate to substantial. Sensitivity, specificity, and overall diagnostic accuracy of HRCT were 98%, 23% and 87%, respectively. Reproducibility was substantial. Conclusion Statistically significant associations between SPN MRCs, calcification patterns, pleural retraction and malignancy were found. HRCT yielded a very high sensitivity and a somewhat lower specificity for malignancy. Reproducibility was high

  14. High resolution spiral CT for determining the malignant potential of solitary pulmonary nodules: refining and testing the test

    International Nuclear Information System (INIS)

    Harders, Stefan Walbom; Madsen, Hans Henrik; Rasmussen, Finn; Rasmussen, Torben Riis; Hager, Henrik

    2011-01-01

    Background A solitary pulmonary nodule (SPN) may represent early stage lung cancer. Lung cancer is a devastating disease with an overall 5-year mortality rate of approximately 84% but with early detection and surgery as low as 47%. Currently a contrast-enhanced multiple-row detector CT (MDCT) scan is the first examination when evaluating patients with suspected lung cancer. Purpose To apply an additional high resolution CT (HRCT) to SPNs to test whether certain morphological characteristics are associated with malignancy, to assess the diagnostic accuracy of HRCT in the characterization of SPNs, and to address the reproducibility of all measures. Material and Method Two hundred and thirteen participants with SPNs were included in a follow-up study. Blinded HRCT images were assessed with regard to margin risk categories (MRCs), calcification patterns and certain other characteristics and overall malignancy potential ratings (MPRs) were given. Morphological characteristics were tested against reference standard and ROC methodology was applied to assess diagnostic accuracy. Reproducibility was measured with Kappa statistics and 95% confidence intervals were computed for all results. Histopathology (90%) and CT follow-up (10%) were used as reference standard. Results MRCs (P < 0.001), calcification patterns (P = 0.003), and pleural retraction (P < 0.001) were all statistically significantly associated to malignancy. Reproducibility was moderate to substantial. Sensitivity, specificity, and overall diagnostic accuracy of HRCT were 98%, 23% and 87%, respectively. Reproducibility was substantial. Conclusion Statistically significant associations between SPN MRCs, calcification patterns, pleural retraction and malignancy were found. HRCT yielded a very high sensitivity and a somewhat lower specificity for malignancy. Reproducibility was high

  15. Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination.

    Science.gov (United States)

    Hong, Sun Suk; Lee, Jong-Woong; Seo, Jeong Beom; Jung, Jae-Eun; Choi, Jiwon; Kweon, Dae Cheol

    2013-12-01

    The purpose of this research is to determine the adaptive statistical iterative reconstruction (ASIR) level that enables optimal image quality and dose reduction in the chest computed tomography (CT) protocol with ASIR. A chest phantom with 0-50 % ASIR levels was scanned and then noise power spectrum (NPS), signal and noise and the degree of distortion of peak signal-to-noise ratio (PSNR) and the root-mean-square error (RMSE) were measured. In addition, the objectivity of the experiment was measured using the American College of Radiology (ACR) phantom. Moreover, on a qualitative basis, five lesions' resolution, latitude and distortion degree of chest phantom and their compiled statistics were evaluated. The NPS value decreased as the frequency increased. The lowest noise and deviation were at the 20 % ASIR level, mean 126.15 ± 22.21. As a result of the degree of distortion, signal-to-noise ratio and PSNR at 20 % ASIR level were at the highest value as 31.0 and 41.52. However, maximum absolute error and RMSE showed the lowest deviation value as 11.2 and 16. In the ACR phantom study, all ASIR levels were within acceptable allowance of guidelines. The 20 % ASIR level performed best in qualitative evaluation at five lesions of chest phantom as resolution score 4.3, latitude 3.47 and the degree of distortion 4.25. The 20 % ASIR level was proved to be the best in all experiments, noise, distortion evaluation using ImageJ and qualitative evaluation of five lesions of a chest phantom. Therefore, optimal images as well as reduce radiation dose would be acquired when 20 % ASIR level in thoracic CT is applied.

  16. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  17. Dual energy CT iodine map for delineating inflammation of inflammatory arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Takeshi; Fukuda, Kunihiko [The Jikei University School of Medicine, Department of Radiology, Tokyo (Japan); Umezawa, Yoshinori; Asahina, Akihiko; Nakagawa, Hidemi [The Jikei University School of Medicine, Department of Dermatology, Tokyo (Japan); Furuya, Kazuhiro [The Jikei University School of Medicine, Division of Rheumatology Department of Internal Medicine, Tokyo (Japan)

    2017-12-15

    Iodine mapping is an image-processing technique used with dual-energy computed tomography (DECT) to improve iodine contrast resolution. CT, because of its high spatial resolution and thin slice reconstruction, is well suited to the evaluation of the peripheral joints. Recent developments in the treatment of inflammatory arthritis that require early diagnosis and precise therapeutic assessment encourage radiological evaluation. To facilitate such assessment, we describe DECT iodine mapping as a novel modality for evaluating rheumatoid arthritis and psoriatic arthritis of the hands and feet. (orig.)

  18. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

    Science.gov (United States)

    Burger, C; Goerres, G; Schoenes, S; Buck, A; Lonn, A H R; Von Schulthess, G K

    2002-07-01

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.

  19. CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions

    Energy Technology Data Exchange (ETDEWEB)

    Muthusami, Prakash; Rea, Vanessa; Shroff, Manohar [The Hospital for Sick Children, Pediatric Neuroradiology and Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Shkumat, Nicholas [The Hospital for Sick Children, Medical Physics, Department of Diagnostic Imaging, Toronto, ON (Canada); Chiu, Albert H. [Institute of Neurological Sciences, Prince of Wales Hospital, Department of Interventional Neuroradiology, Randwick, NSW (Australia)

    2017-06-15

    Complex neurovascular lesions in children require precise anatomic understanding for treatment planning. Although 3DRA is commonly employed for volumetric reformation in neurointerventional procedures, the ability to reconstruct this data into CT-like images (3DRA-CT) is not widely utilized. This study demonstrates the feasibility and usefulness of 3DRA-CT and subsequent MRI fusion for problem solving in pediatric neuroangiography. This retrospective study includes 18 3DRA-CT studies in 16 children (age 9.6 ± 3.8 years, range 2-16 years) over 1 year. After biplane 2D-digital subtraction angiography (DSA), 5-second 3DRA was performed with selective vessel injection either with or without subtraction. Images were reconstructed into CT sections which were post-processed to generate multiplanar reformation (MPR) and maximum intensity projection (MIP) images. Fusion was performed with 3D T1 MRI images to precisely demonstrate neurovascular relationships. Quantitative radiation metrics were extracted and compared against those for the entire examination and for corresponding biplane 2D-DSA acquisitions. In all 18 cases, the 3DRA procedure and MRI fusion were technically successful and provided clinically useful information relevant to management. The unsubtracted and subtracted 3DRA acquisitions were measured to deliver 5.9 and 132.2%, respectively, of the mean radiation dose of corresponding biplane 2D-DSA acquisitions and contributed 1.2 and 12.5%, respectively, to the total procedure dose. Lower radiation doses, high spatial resolution, and multiplanar reformatting capability make 3DRA-CT a useful adjunct to evaluate neurovascular lesions in children. Fusing 3DRA-CT data with MRI is an additional capability that can further enhance diagnostic information. (orig.)

  20. Evaluation of abdominal CT in the initial treatment of abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishii, Takashi; Kuwata, Katsuya; Yoneyama, Chihiro; Kitamura, Kazuya; Sasaki, Yoshifumi; Kamachi, Masahiro; Nishiguchi, Hiroyasu.

    1986-01-01

    During the last four years 102 patients with abdominal trauma were examined by CT for preoperative evaluation in our hospital. In 35 patients (34 %), the CT scans revealed no abnormal findings. They were all managed conservatively except for one case of perforated small bowel. In 67 patients (66 %) CT revealed evidences of substantial abdominal or retroperitoneal trauma. In 30 of them CT findings were confirmed by surgery. Hepatic injury is usually easily recognized by CT. CT is also useful for the detection of renal or splenic injuries. The majority of those parenchymatous organ injuries were successfully managed with conservative therapy, despite apparent traumatic lesions revealed by CT. Repeat CT scans is proved to be very useful to follow the changes of these traumatic lesions. In conclusion, application of abdominal CT is extremely useful for the initial decision making in treatment of patients with abdominal trauma and for the follow-up observation of injured lesions. (author)

  1. Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis

    International Nuclear Information System (INIS)

    Mori, Yoshiko; Yamasaki, Michio; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2001-01-01

    To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall was observed in all 29 cases of phlegmonous appendicitis (100%), but in only 66.7% (18 cases) of gangrenous appendicitis. Deficiency of the appendiceal wall was more frequently observed in gangrenous (19/27, 70.4%) than phlegmonous appendicitis (4/29, 13.8%). Findings of enhanced CT provide useful information in evaluating the pathological severity of acute appendicitis. (author)

  2. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  3. Cine CT in the evaluation of coronary bypass graft patency

    International Nuclear Information System (INIS)

    Stanford, W.; Rooholamini, M.; Rumberger, J.; Marcus, M.; Hiratzka, L.

    1986-01-01

    Cine CT produces axial images over an 8-cm section of the aorta in 50 msec. This characteristic makes the technique useful for evaluating coronary bypass graft (CBG) patency. With the use of 40 ml of 67% iothalamate sodium injected via an antecubital vein, 28 patients with 68 CBGs underwent cine CT. Ten patients with 21 CBGs also underwent cardiac catheterization. In the latter group the overall accuracy of cine CT compared to cardiac catheterization was 95.2% (20/21). The sensitivity was 94.1% (16/17), and the specificity was 100% (4/4). This figure compares favorably with the 92% sensitivity achieved with conventional CT

  4. Is PET/CT efficient tool to evaluate the response after stereotactic radiation therapy for pancreas cancer?

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seong Yul; Cho, Chul Koo

    2005-01-01

    In pancreas cancer, to evaluate the efficacy of PET/CT as tool to check the response after stereotactic radiation therapy and to define functional imaging role of PET/CT as alterative tool of computed tomography. From November 2003 to December 2004, among locally advanced pancreas cancer patients treated by stereotactic radiation therapy using CyberKnife(CK), 14 were evaluated by PET/CT before and after treatment. Four patients took PET/CT one month after CK, 4 patients 2 months after CK, and 6 patients 3 months after CK as the first evaluation of treatment. All of patients were also evaluated by CT or CA19-9 tumor antigen with the range of 1-2 months after CK. In addition of PET/CT to CT, lymph node metastasis were revealed as positive in 4 patients who had negative finding on CT. Furthermore, patients who showed partial or complete response on PET/CT findings that checked within 3 months after CK have significantly longer median survival time than patients who showed no response or disease progression(13 months and 9 months, respectively). Responses based on CA19-9 tumor antigen or CT, however, showed no significant difference in terms of median survival time. PET/CT can provide more information for lymph node metastasis compared to CT alone. It is very helpful for delineation of tumor extent for CK planning. And initial response on PET/CT scan could be a significant prognostic factor rather than response on CA19-9 level or CT. In the future, more study is necessary to evaluate if PET/CT could substitute CT and finally CT could be omitted during follow-up period after CK

  5. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnaure, I.; Lovblad, K.O.; Vargas, M.I. [Geneva University Hospital, Department of Neuroradiology, Geneva 14 (Switzerland); Pollak, P.; Horvath, J.; Boex, C.; Burkhard, P. [Geneva University Hospital, Department of Neurology, Geneva (Switzerland); Momjian, S. [Geneva University Hospital, Department of Neurosurgery, Geneva (Switzerland); Remuinan, J. [Geneva University Hospital, Department of Radiology, Geneva (Switzerland)

    2015-09-15

    Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS. (orig.)

  6. Assessment of subpleural opacities on high-resolution CT

    International Nuclear Information System (INIS)

    Choi, Hee Seok; Kim, Jeung Sook; Kang, Eun Young; Kim, Hak Hee

    2007-01-01

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis

  7. Assessment of subpleural opacities on high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hee Seok; Kim, Jeung Sook [Dngguk University International Hospital, Goyang (Korea, Republic of); Kang, Eun Young [Korea University Guro Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2007-11-15

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis.

  8. An evaluation of the use of oral contrast media in abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro [Mater Dei Hospital, Medical Imaging Department, Msida (Malta); Borg Grima, Karen; Zarb, Francis [Mater Dei Hospital, Faculty of Health Sciences, Msida (Malta)

    2014-11-15

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  9. An evaluation of the use of oral contrast media in abdominopelvic CT

    International Nuclear Information System (INIS)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro; Borg Grima, Karen; Zarb, Francis

    2014-01-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  10. How to use PET/CT in the evaluation of response to radiotherapy.

    Science.gov (United States)

    Decazes, Pierre; Thureau, Sébastien; Dubray, Bernard; Vera, Pierre

    2017-11-28

    Radiotherapy is a major treatment modality for many cancers. Tumor response after radiotherapy determines the subsequent steps of the patient's management (surveillance, adjuvant or salvage treatment and palliative care). Tumor response assessed during radiotherapy offers a promising opportunity to adapt the treatment plan to reduced / increased target volume, to specifically target sub-volumes with relevant biological characteristics (metabolism, hypoxia, proliferation ...) and to further spare the organs at risk. In addition to its role in the diagnosis and the initial staging, Positron Emission Tomography combined with a Computed Tomography (PET/CT) provides functional information and is therefore attractive to evaluate tumor response. To review the published data addressing PET/CT as an evaluation tool in irradiated tumors. Reports on PET/CT acquired at various times (during radiotherapy, after initial (chemo-)radiotherapy, after definitive radiotherapy and during posttreatment follow-up) in solid tumors (lung, head-and-neck, cervix, esophagus, prostate and rectum) were collected and reviewed. Various tracers and technical are also discussed. 18F-FDG PET/CT has a well-established role in clinical routine after definitive chemo-radiotherapy for locally advanced head-and-neck cancers. 18F-choline PET/CT is indicated in prostate cancer patients with biochemical failure. 18F-FDG PET/CT is optional in many others circumstances and the clinical benefits of assessing tumor response with PET/CT remain a field of very active research. The combination of PET with Magnetic Resonance Imaging (PET/MRI) may prove to be valuable in irradiated rectal and cervix cancers. Tumor response can be evaluated by PET/CT with clinical consequences in multiple situations, notably in head and neck and prostate cancers, after radiotherapy. Further clinical evaluation for most cancers is still needed, possibly in association to MRI.

  11. CT evaluation of the bile ducts in patients with fatty liver

    International Nuclear Information System (INIS)

    Quint, L.E.; Glazer, G.M.

    1984-01-01

    Computed tomographic (CT) evaluation of the bile ducts in the fatty liver can be difficult, since hepatic attenuation decreases with increased triglyceride content, and liver parenchyma may become isodense with bile. Forty-seven patients with fatty infiltration of the liver were retrospectively identified. In 7 of these patients, attenuation of liver and bile differed by less than 10 HU. In 2 patients, dilated intrahepatic ducts were invisible using CT, because bile was isodense with fatty liver parenchyma. Thus, the fatty liver presents a potential pitfall in CT evaluation of the bile ducts. For maximal accuracy scans should be obtained both before and after administration of intravenous urographic contrast material

  12. An evaluation on CT image acquisition method for medical VR applications

    Science.gov (United States)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  13. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

    Science.gov (United States)

    Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain

    2018-05-01

    To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) statistic (F)=28.52, padvanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.

  14. CT in the diagnosis of isolated cysticercal infestation of extraocular muscle

    International Nuclear Information System (INIS)

    Rauniyar, R.K.; Thakur, S.K.D.; Panda, A.

    2003-01-01

    AIM: To evaluate the use of computed tomography (CT) and ultrasound (US) to diagnose orbital cysticercosis, and present the diagnostic features. METHOD: US and CT were used to evaluate patients with proptosis. Four patients were diagnosed as having orbital myocysticercosis and treated with oral albendazole and corticosteroid. Follow-up was undertaken with US and CT. RESULT: US features were confirmatory of myocysticercosis in two eyes where as CT was effective in diagnosing the condition in all four eyes. In two patients the medial rectus was involved, in one the superior rectus and, in the other, the inferior rectus muscles. Serial US and CT revealed complete resolution of the lesions in 3 months. CONCLUSION: CT is useful method in diagnosing isolated orbital myocysticercosis. Our report demonstrated that ophthalmic signs and symptoms in the presence of proptosis, especially in an endemic region, should alert the clinician to the possibility of myocysticercosis. Though CT is superior, US can be used as a economical follow-up investigation. Rauniyar, R. K. etal. (2003) Clinical Radiology58, 154--156

  15. CT in the diagnosis of isolated cysticercal infestation of extraocular muscle

    Energy Technology Data Exchange (ETDEWEB)

    Rauniyar, R.K.; Thakur, S.K.D.; Panda, A

    2003-02-01

    AIM: To evaluate the use of computed tomography (CT) and ultrasound (US) to diagnose orbital cysticercosis, and present the diagnostic features. METHOD: US and CT were used to evaluate patients with proptosis. Four patients were diagnosed as having orbital myocysticercosis and treated with oral albendazole and corticosteroid. Follow-up was undertaken with US and CT. RESULT: US features were confirmatory of myocysticercosis in two eyes where as CT was effective in diagnosing the condition in all four eyes. In two patients the medial rectus was involved, in one the superior rectus and, in the other, the inferior rectus muscles. Serial US and CT revealed complete resolution of the lesions in 3 months. CONCLUSION: CT is useful method in diagnosing isolated orbital myocysticercosis. Our report demonstrated that ophthalmic signs and symptoms in the presence of proptosis, especially in an endemic region, should alert the clinician to the possibility of myocysticercosis. Though CT is superior, US can be used as a economical follow-up investigation. Rauniyar, R. K. etal. (2003) Clinical Radiology58, 154--156.

  16. Comparison of PET/CT and whole-mount histopathology sections of the human prostate: a new strategy for voxel-wise evaluation.

    Science.gov (United States)

    Schiller, F; Fechter, T; Zamboglou, C; Chirindel, A; Salman, N; Jilg, C A; Drendel, V; Werner, M; Meyer, P T; Grosu, A-L; Mix, M

    2017-08-17

    Implementation of PET/CT in diagnosis of primary prostate cancer (PCa) requires a profound knowledge about the tracer, preferably from a quantitative evaluation. Direct visual comparison of PET/CT slices to whole prostate sections is hampered by considerable uncertainties from imperfect coregistration and fundamentally different image modalities. In the current study, we present a novel method for advanced voxel-wise comparison of histopathology from excised prostates to pre-surgical PET. Resected prostates from eight patients who underwent PSMA-PET/CT were scanned (ex vivo CT) and thoroughly pathologically prepared. In vivo and ex vivo CT including histopathology were coregistered with three different methods (manual, semi-/automatic). Spatial overlap after CT-based registration was evaluated with dice similarity (DSC). Furthermore, we constructed 3D cancer distribution models from histopathologic information in various slices. Subsequent smoothing reflected the intrinsically limited spatial resolution of PSMA-PET. The resulting histoPET models were used for quantitative analysis of spatial histopathology-PET pattern agreement focusing on p values and coefficients of determination (R 2 ). We examined additional rigid mutual information (MI) coregistration directly based on PSMA-PET and histoPET. Mean DSC for the three different methods (ManReg, ScalFactReg, and DefReg) were 0.79 ± 0.06, 0.82 ± 0.04, and 0.90 ± 0.02, respectively, while quantification of PET-histopathology pattern agreement after CT-based registration revealed R 2 45.7, 43.2, and 41.3% on average with p PET-based MI coregistration yielded R 2 61.3, 55.9, and 55.6%, respectively, while implying anatomically plausible transformations. Creating 3D histoPET models based on thorough histopathological preparation allowed sophisticated quantitative analyses showing highly significant correlations between histopathology and (PSMA-)PET. We recommend manual CT-based coregistration followed by a PET

  17. Performance evaluation of X-ray CT using visible scintillation light

    International Nuclear Information System (INIS)

    Kodama, Kiyoyuki; Hamada, Minoru; Suzuki, Tamotsu; Hashimoto, Masatoshi; Hanada, Takashi; Ide, Tatsuya; Maruyama, Koichi

    2004-01-01

    We proposed a new method of performance evaluation for X-ray CT using visible scintillation light and examined its usefulness in this study. When we scanned a plastic scintillator disk in a gantry opening of the X-ray CT, we could observe visible scintillation light. The rotation of the light-emitting area of the disk corresponded to that of the X-ray tube. We were able to record the scintillation light by digital video camera. By analyzing the area of visible scintillation light, the rotation speed of the X-ray tube, angular spread of the X-ray beam, uniformity of the incident X-rays, and change in X-ray energy were measured. No other method is available to obtain the above parameters of X-ray CT during a single CT scan. In the measurements of the uniformity of incident X-rays and change of X-ray energy, our method showed good accuracy in detecting the attenuation caused by the couch between the X-ray tube and the plastic scintillator disc. The proposed method is inexpensive and easy-to-use. We conclude that the method is a useful tool for performance evaluation as well as a maintenance tool for X-ray CT. (author)

  18. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

    Science.gov (United States)

    Yu, Zhicong; Leng, Shuai; Jorgensen, Steven M; Li, Zhoubo; Gutjahr, Ralf; Chen, Baiyu; Halaweish, Ahmed F; Kappler, Steffen; Yu, Lifeng; Ritman, Erik L; McCollough, Cynthia H

    2016-02-21

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  19. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

    International Nuclear Information System (INIS)

    Yu, Zhicong; Leng, Shuai; Li, Zhoubo; Chen, Baiyu; Yu, Lifeng; McCollough, Cynthia H; Jorgensen, Steven M; Ritman, Erik L; Gutjahr, Ralf; Kappler, Steffen; Halaweish, Ahmed F

    2016-01-01

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  20. CT in the evaluation of patients on ECMO due to acute respiratory failure

    International Nuclear Information System (INIS)

    Lidegran, Marika; Jorulf, Haakan; Palmer, Kenneth; Linden, Viveka

    2002-01-01

    Heading AbstractBackground. In patients with acute severe respiratory failure (ARF) treated with extracorporeal membrane oxygenation (ECMO) the radiological evaluation has until now almost exclusively relied on bedside radiography and US. At St. Goeran/Karolinska ECMO centre CT has become a routine complement to bedside examinations.Objective. To review retrospectively the frequency, indications and findings on CT of patients with ARF on ECMO and to evaluate the risk of complications associated with transportation for CT examinations.Materials and methods. One hundred twelve neonates, children and adults were treated with ECMO from May 1994 to January 2001. Forty-six per cent of these patients had CT examinations on one or more occasions during ECMO, giving a total number of 238 examination sites on 104 occasions. All CT examinations were performed in the Paediatric Radiology Department and included a 10-min transport using a mobile ECMO system.Results. CT was more often performed in older patients and in patients with long ECMO runs. The main indications were suspected complications of ECMO and/or the underlying disease or a delay in clinical improvement. In 57% of the CT occasions, significant findings affecting treatment were revealed. There were no complications associated with the examinations or transport.Conclusions. CT is safe and useful in evaluation of patients with ARF during ECMO. (orig.)

  1. The CT evaluation of cephalic and cervical adenoid cystic carcinoma

    International Nuclear Information System (INIS)

    Gu Yajia; Wang Jiuhua; Wang HOngshi; Chen Tongzhen

    2000-01-01

    Objective: To evaluate the CT manifestations of cephalic and cervical adenoid cystic carcinoma (ACC). Methods: Thirty-three cases of ACC were analyzed retrospectively. Of all cases, 22 cases underwent operation and 11 cases received radiotherapy. The manifestations of CT were evaluated and compared with the clinical and pathologic results. Results: Tumors originated from parotid gland (5 cases), floor of mouth (5 cases), nasal cavity and nasopharynx (5 cases), tongue (4 cases), palate (3 cases), tracheas (3 cases), submandibular gland (2 cases), tonsilla (2 cases), maxillary sinus (2 cases), and cheek (2 cases), respectively. The CT manifestations included: (1)ethmoid density in 21 cases, partial ethmoid density in 5 cases. (2)the morphology of ACC was irregular and the growth of the tumor was amorphous in 17 cases, and the margin of the tumor was vague in 20 cases. (3)ACC often grew along the nerve with infiltration, which caused destruction of the skull base in 5 cases and atrophy of mastication muscles and/or buccinator in 3 cases. Conclusion: (1)The characteristics of cephalic and cervical adenoid cystic carcinoma on CT scans were ethmoid density, infiltrated growth, growing along the nerve with infiltration, and submucous growth. Among them, the most important manifestation, which could lead to the histologic diagnosis on CT, was ethmoid density. (2)The range of ACC was usually underestimated on CT. (3)The manifestation of tumor growth along the nerve could be apparently displayed on MRI

  2. Technical principles of dual source CT

    International Nuclear Information System (INIS)

    Petersilka, Martin; Bruder, Herbert; Krauss, Bernhard; Stierstorfer, Karl; Flohr, Thomas G.

    2008-01-01

    During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's 64 slice CT systems allow whole-body examinations with sub-millimeter resolution in short scan times. As an alternative to adding even more detector slices, we describe the system concept and design of a CT scanner with two X-ray tubes and two detectors (mounted on a CT gantry with a mechanical offset of 90 deg.) that has the potential to overcome limitations of conventional MDCT systems, such as temporal resolution for cardiac imaging. A dual source CT (DSCT) scanner provides temporal resolution equivalent to a quarter of the gantry rotation time, independent of the patient's heart rate (83 ms at 0.33 s rotation time). In addition to the benefits for cardiac scanning, it allows to go beyond conventional CT imaging by obtaining dual energy information if the two tubes are operated at different voltages. Furthermore, we discuss how both acquisition systems can be used to add the power reserve of two X-ray tubes for long scan ranges and obese patients. Finally, future advances of DSCT are highlighted

  3. High-resolution CT of the lung in asbestos-exposed subjects. Comparison of low-dose and high-dose HRCT

    International Nuclear Information System (INIS)

    Majurin, M.L.; Varpula, M.; Kurki, T.; Pakkala, L.

    1994-01-01

    The lowest possible mAs settings for high-resolution CT (HRCT) were studied on 45 individuals with suspected asbestos-related lung disease. All patients were investigated with 5 to 6 high-dose HRCT images (120 kVp/160 mA/2 s) at 3-cm intervals. At a selected level 4 additional low-dose images were obtained on each patient with lower mAs settings (100 mA/2 s, 80 mA/2 s, 60 mA/2 s, 30 mA/2 s). Thirty-seven subjects out of 45 had HRCT lesions compatible with asbestosis. HRCT images obtained with as low as 60 mA/2 s settings clearly showed pleural tractions and thickenings, parenchymal bands, honeycombing and subpleural curvilinear shadows, whereas in the evaluation of subpleural short lines and ground glass findings 80 mA/2 s were required. The lowest setting, 30 mA/2 s, was sufficient only in detecting and evaluating pleural tractions and thickenings. We conclude that 160 mAs yield good quality HRCT images, with substantial decrease of radiation dose, for the evaluation of asbestos-related lesions. (orig.)

  4. Follow-up CT Evaluation of the Mural Changes in Active Takayasu Arteritis

    International Nuclear Information System (INIS)

    Kim, Sang Young; Park, Jae Hyung; Chung, Jin Wook; Kim, Hyo Cheol; Lee, Whal; So, Young Ho; Jae, Hwan Jun

    2007-01-01

    We wanted to evaluate the mural changes by CT on the follow-up examination of patients with active Takayasu arteritis. The study included 18 patients, (4 males and 14 females), with active Takayasu arteritis. A total of 44 CT examinations were done during the follow-up period (mean: 55.6 months). At the time of the last follow-up CT, the disease, on the basis of the erythrocyte sedimentation rate (ESR), was found to be inactive in five patients and the disease was active and persistent in 13 patients. The thickness and CT attenuation of the aortic wall on the precontrast, arterial and venous phases were measured on the initial and the follow-up CT examinations. The ratio of the mural attenuation over that of the back muscle on the initial CT was compared with the ratio found on the follow-up CT. The initial CT findings included high density and calcifications of the aortic wall in the precontrast images and a thickened wall with enhancements in the arterial and the venous phases. A low-attenuation ring was demonstrated in the venous phase in 15 patients (83%). On the follow-up evaluation, the mean mural thickness decreased significantly from 4.1 mm to 2.4 mm. The mean mural attenuation ratio in the venous phase decreased significantly from 1.9 to 1.3 (p 0.001). The low attenuation ring was identified in seven patients (39%) who had only with active, persistent Takayasu arteritis. The mural changes demonstrated by the follow-up CT evaluations for the patients with active Takayasu arteritis included a decrease of the mural thickness and enhancement, disappearance of the low-attenuation ring on the venous phase, and an increase of the mural attenuation and calcification on the precontrast phase

  5. The clinical evaluation of CT and radionuclide examination in renal diseases

    International Nuclear Information System (INIS)

    Kutani, Wataru; Ishida, Hirofumi; Shirakawa, Shigetoshi; Shintaku, Takao; Funaki, Ryo

    1980-01-01

    One hundred and twelve cases of renal diseases were studied by computed tomography (CT) using EMI 5005/12. Of them, 60 were examined by both CT and renal scintigraphy, and comparatively evaluated. The CT units were checked before and after the contrast enhancement. Renal scintigrams were obtained by gamma cameras (PHO/GAMMA HP 6406, PHO/GAMMA LFOV) using 99 M Tc-DMSA. CT was especially useful in diagnosing the renal cysts and the hydronephrosis. Cysts in other organs (liver, spleen and pancreas) were simultaneously ascertained in polycystic diseases. CT was not helpful in diagnosing nephritis and diabetic nephropathy. Floating kidney and horse-shoe kidney were difficult to diagnose with CT. The renal scintigram was the reflection of the renal function, and was relatively more useful than CT in diagnosing horse-shoe kidney, floating kidney and nephritis, while it was not useful for non-functioning kidneys. (author)

  6. Precision of DVC approaches for strain analysis in bone imaged with μCT at different dimensional levels.

    Science.gov (United States)

    Dall'Ara, Enrico; Peña-Fernández, Marta; Palanca, Marco; Giorgi, Mario; Cristofolini, Luca; Tozzi, Gianluca

    2017-11-01

    Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-Computed Tomography (µCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application the precision of the method should be evaluated. In this paper we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source µCT or Synchrotron light µCT (SRµCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2500 micrometers. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time large differences in the precision of both local and global DVC approaches have been highlighted when SRµCT or in vivo µCT images were used instead of conventional ex vivo µCT. These findings suggest that in situ mechanical testing protocols applied in SRµCT facilities should be optimized in order to allow DVC analyses of localized strain measurements. Moreover, for in vivo µCT applications DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion

  7. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  8. The role of high-resolution CT in evaluating disease of the posterior tympanum

    International Nuclear Information System (INIS)

    Funai, Hiroaki; Takubo, Masamichi; Iinuma, Toshitaka; Horiuchi, Yasuharu; Ichimura, Keiichi; Oyama, Kazuyuki.

    1989-01-01

    The posterior tympanum consists of several irregular eminences, ridges, and sinuses. These sinuses do not communicate with the mastoid air cell system, and cholesteatoma and/or granulation tissue prefer to fill them. This area cannot be visualized with ease by the usual surgical approach, and is thus quite important for surgeons. Recent developments in high-resolution computed tomography (HRCT) allow more than ever precise identification of subtle changes in the posterior tympanum. Axial HRCT sections provide essential information for the preoperative evaluation of the posterior tympanum. The performance of surgeons has been promoted both in evaluation and treatment planning of patient with suspected posterior tympanic lesions. HRCT findings were compared with the operative findings in 52 patients (54 ears) who had the operation for chronic otitis media. Important findings by HRCT diagnosis of posterior tympanum are as follows; (1) Bone destruction in the posterosuperior part of the tympanic anulus and in the lateral wall of the facial sinus are the important findings for the diagnosis of invasion of cholesteatoma in the posterior tympanum. (2) Similarly important finding is the bone destruction of the pyramidal eminence. This was found in 6 of 9 cases with cholesteatomas extending into the sinus tympani. (3) The soft tissue density in the posterior tympanum does not necessarily indicate pathological processes. Effusion in the posterior tympanum is imaged as soft tissue density, and can not be differentiated from cholesteatoma or granulation by present HRCT. (author)

  9. 'Crazy-Paving' Patterns on High-Resolution CT Scans in Patients with Pulmonary Complications after Hematopoietic Stem Cell Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Escuissato, Dante L.; Gasparetto, Taisa Davaus; Considera, Daniela Peixoto [Federal University, Sao Paulo (Brazil); Franquet, Tomas [Hospital de Sant Pau, Universitat Autonoma de Barcelona, Barcelona (Spain)

    2009-02-15

    To describe the pulmonary complications following hematopoietic stem cell transplantation (HSCT) that can present with a 'crazy-paving' pattern in high-resolution CT scans. Retrospective review of medical records from 2,537 patients who underwent HSCT. The 'crazy-paving' pattern consists of interlobular and intralobular septal thickening superimposed on an area of ground-glass attenuation on high-resolution CT scans. The CT scans were retrospectively reviewed by two radiologists, who reached final decisions by consensus. We identified 10 cases (2.02%), seven male and three female, with pulmonary complications following HSCT that presented with the 'crazy-paving' pattern. Seven (70%) patients had infectious pneumonia (adenovirus, herpes simplex, influenza virus, cytomegalovirus, respiratory syncytial virus, and toxoplasmosis), and three patients presented with non-infectious complications (idiopathic pneumonia syndrome and acute pulmonary edema). The 'crazy-paving' pattern was bilateral in all cases, with diffuse distribution in nine patients (90%), predominantly in the middle and inferior lung regions in seven patients (70%), and involving the anterior and posterior regions of the lungs in nine patients (90%). The 'crazy-paving' pattern is rare in HSCT recipients with pulmonary complications and is associated with infectious complications more commonly than non-infectious conditions.

  10. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  11. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  12. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  13. PET/CT in therapy evaluation of patients with lung cancer

    DEFF Research Database (Denmark)

    Langer, Natasha Hemicke; Christensen, Tine Nøhr; Langer, Seppo W

    2014-01-01

    FDG-PET/CT is a well documented and widespread used imaging modality for the diagnosis and staging of patient with lung cancer. FDG-PET/CT is increasingly used for the assessment of treatment effects during and after chemotherapy. However, PET is not an accepted surrogate end-point for assessment...... of response rate in clinical trials. The aim of this review is to present current evidence on the use of PET in response evaluation of patients with lung cancer and to introduce the pearls and pitfalls of the PET-technology relating to response assessment. Based on this and relating to validation criteria......, including stable technology, standardization, reproducibility and broad availability, the review discusses why, despite numerous studies on response assessment indicating a possible role for FDG-PET/CT, PET still has no place in guidelines relating to response evaluation in lung cancer....

  14. SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

    International Nuclear Information System (INIS)

    Zhang, J; Ge, G; Winkler, M; Cong, W; Wang, G

    2014-01-01

    Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose

  15. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  16. CT evaluation of underlying cause in spontaneous subcapsular and perirenal hemorrhage

    International Nuclear Information System (INIS)

    Sebastia, M.C.; Perez-Molina, M.O.; Alvarez-Castells, A.; Quiroga, S.; Pallisa, E.

    1997-01-01

    We evaluated the CT scans of 13 patients with spontaneous subcapsular or perinephric hemorrhage (SPH) associated with these underlying causes: 4 angiomyolipomas, 2 renal cell carcinomas, 1 renal metastatic malignant melanoma, 1 ruptured renal artery aneurysm, 1 adrenal myelolipoma, 1 ruptured renal abscess, 2 ruptured hemorrhagic cysts, and 1 patient with undiagnosed coagulation disorder. Our objective was to ascertain whether an underlying cause of SPH was identifiable by CT, and to determine the extension of the hematomas. Computed tomography identified the hematoma in all 13 cases (sensitivity 100 %). In all 12 cases in which there was a renal or adrenal anatomic lesion, the underlying cause was identified with CT (100 %), with correct diagnosis in 11 cases (91.6 %). The case in which no lesion was identified was the undiagnosed coagulation disorder. We conclude that CT is a useful technique for the initial evaluation of SPH, permitting diagnosis of hemorrhage and identification of the underlying cause. (orig.). With 6 figs., 1 tab

  17. CT evaluation of underlying cause in spontaneous subcapsular and perirenal hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Sebastia, M.C. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Perez-Molina, M.O. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Alvarez-Castells, A. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Quiroga, S. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Pallisa, E. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain)

    1997-06-01

    We evaluated the CT scans of 13 patients with spontaneous subcapsular or perinephric hemorrhage (SPH) associated with these underlying causes: 4 angiomyolipomas, 2 renal cell carcinomas, 1 renal metastatic malignant melanoma, 1 ruptured renal artery aneurysm, 1 adrenal myelolipoma, 1 ruptured renal abscess, 2 ruptured hemorrhagic cysts, and 1 patient with undiagnosed coagulation disorder. Our objective was to ascertain whether an underlying cause of SPH was identifiable by CT, and to determine the extension of the hematomas. Computed tomography identified the hematoma in all 13 cases (sensitivity 100 %). In all 12 cases in which there was a renal or adrenal anatomic lesion, the underlying cause was identified with CT (100 %), with correct diagnosis in 11 cases (91.6 %). The case in which no lesion was identified was the undiagnosed coagulation disorder. We conclude that CT is a useful technique for the initial evaluation of SPH, permitting diagnosis of hemorrhage and identification of the underlying cause. (orig.). With 6 figs., 1 tab.

  18. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  19. Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition

    International Nuclear Information System (INIS)

    Bruder, H; Raupach, R; Sunnegardh, J; Allmendinger, T; Klotz, E; Stierstorfer, K; Flohr, T

    2015-01-01

    In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta.Examples: in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectral dataset of the same body region provides additional quanta which might be utilized to improve SNR of each spectral component. Perfusion CT is a high dose application, and dose reduction is highly desirable. However, a meaningful evaluation of perfusion parameters might be impaired by noisy time frames. On the other hand, the SNR of the average of all time frames is extremely high.In redundant CT acquisitions, multiple image datasets can be reconstructed and averaged to composite image data. These composite image data, however, might be compromised with respect to contrast resolution and/or spatial resolution and/or temporal resolution. These observations bring us to the idea of transferring high SNR of composite image data to low SNR ‘source’ image data, while maintaining their resolution.It has been shown that the noise characteristics of CT image data can be improved by iterative reconstruction (Popescu et al 2012 Book of Abstracts, 2nd CT Meeting (Salt Lake City, UT) p 148). In case of data dependent Gaussian noise it can be modelled with image-based iterative reconstruction at least in an approximate manner (Bruder et al 2011 Proc. SPIE 7961 79610J).We present a generalized update equation in image space, consisting of a linear combination of the previous update, a correction term which is constrained by the source image data, and a regularization prior, which is initialized by the composite image data. This iterative reconstruction approach we call bimodal reconstruction (BMR).Based on simulation data it is shown that BMR can improve low contrast detectability, substantially reduces the noise power and has the potential to recover spatial

  20. Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition

    Science.gov (United States)

    Bruder, H.; Raupach, R.; Sunnegardh, J.; Allmendinger, T.; Klotz, E.; Stierstorfer, K.; Flohr, T.

    2015-11-01

    In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples: in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectral dataset of the same body region provides additional quanta which might be utilized to improve SNR of each spectral component. Perfusion CT is a high dose application, and dose reduction is highly desirable. However, a meaningful evaluation of perfusion parameters might be impaired by noisy time frames. On the other hand, the SNR of the average of all time frames is extremely high. In redundant CT acquisitions, multiple image datasets can be reconstructed and averaged to composite image data. These composite image data, however, might be compromised with respect to contrast resolution and/or spatial resolution and/or temporal resolution. These observations bring us to the idea of transferring high SNR of composite image data to low SNR ‘source’ image data, while maintaining their resolution. It has been shown that the noise characteristics of CT image data can be improved by iterative reconstruction (Popescu et al 2012 Book of Abstracts, 2nd CT Meeting (Salt Lake City, UT) p 148). In case of data dependent Gaussian noise it can be modelled with image-based iterative reconstruction at least in an approximate manner (Bruder et al 2011 Proc. SPIE 7961 79610J). We present a generalized update equation in image space, consisting of a linear combination of the previous update, a correction term which is constrained by the source image data, and a regularization prior, which is initialized by the composite image data. This iterative reconstruction approach we call bimodal reconstruction (BMR). Based on simulation data it is shown that BMR can improve low contrast detectability, substantially reduces the noise power and has the potential to recover

  1. Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Schreyer, A.G.; Jung, E.M.; Heiss, P.; Zorger, N. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schreyer, C.I.; Framme, C. [Klink und Poliklinik fuer Augenheilkunde, Universitaetsklinikum Regensburg (Germany)

    2010-02-15

    Purpose: To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries. Materials and Methods: Based on a retrospective chart review between 2002 and 2007, we identified 59 patients presenting with severe ocular trauma with uncertain rupture of the globe due to massive subconjunctival and/or anterior chamber hemorrhage. The IOP (intraocular pressure) was within normal range in all patients. High resolution multidetector CT (MD-CT) scans (16 slice scans) with axial and coronar reconstructions were performed in all patients. The affected eye was examined for signs of penetrating injury such as abnormal eye shape, scleral irregularities, lens dislocation or intravitreal hemorrhages. Four experienced radiologists read the CT scans independently. Beside the diagnosis, the relevant morphological criteria and the optimal plane orientation (axial or coronar) were specified. The sensitivity, specificity, and negative and positive predictive value were calculated. Additionally the interobserver variability was determined by applying the Cohen's kappa test. Surgical sclera inspections were performed in all cases as a standard of reference. The evaluations of the CT examination were compared with the surgery reports. Results: 59 patients were evaluated (42 men, 17 women). The mean age was 29 years (range 7-91). In 17 patients a rupture of the globe was diagnosed during surgery. 12 of these 17 penetrating injuries (70.6%) were classified correctly by MDCT, 5 of the 17 (29.4%) were not detectable. 42 patients did not have an open globe injury. 41 of these patients were diagnosed correctly negative by MDCT, and one patient was classified false positive. This results in a sensitivity of 70% with a specificity of 98%. There was high inter-rater agreement with kappa values between 0.89-0.96. Most discrepancies were caused by wrong negative findings. The most frequent morphologic criteria for open globe injury were the deformation (n

  2. Significance of 18F-FDG PET/CT imaging in the evaluation of the efficacy of lymphoma

    Institute of Scientific and Technical Information of China (English)

    CHEN Chengcheng; WANG Zhengguang; CHENG Nan

    2014-01-01

    To evaluate the 18F-labeled deoxyglucose (18F-FDG) PET/CT imaging in the evaluation of the efficacy of ly-mphoma significance.Methods:42 cases of our hospital patients with malignant lymphoma for 2-5 times 18F-FDG PET/CT imaging results in the treatment process, and the treatment process simple CT results were compared and analyzed, the final results were confirmed by pathology and clinical. Results:The lesions were found in153,including 141 malignant, benign 12, sensitivity, specificity, and accuracy evaluating of lymphoma treatment effect of 18F-FDG PET/CT were, 99.30%, 91.67%, 98.70%, were significantly better than CT examination (PCT in the evaluation of ly-mphoma treatment was superior to CT scan purely, it is an effective means of monitoring the efficacy of lymphoma, it can provide the basis for effective treatment programs in clinical work.

  3. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  4. Evaluation of primary prostate cancer using 11C-methionine-PET/CT and 18F-FDG-PET/CT.

    Science.gov (United States)

    Shiiba, Masato; Ishihara, Keiichi; Kimura, Go; Kuwako, Tomoyuki; Yoshihara, Hisashi; Yoshihara, Naohisa; Sato, Hidetaka; Kondo, Yukihiro; Tsuchiya, Shin-ichi; Kumita, Shin-ichiro

    2012-02-01

    The objective of this study was to evaluate the capability of (11)C-methionine (MET)-PET/CT and (18)F-2-deoxy-2-fluoro-D: -glucose (FDG)-PET/CT to diagnose primary prostate cancer using recently developed Gemini TF PET/CT (Philips Healthcare, Cleveland, OH). Twenty men who had been referred for a diagnostic work-up for prostate cancer were enrolled in this study. MET- and FDG-PET/CT by high-resolution mode were carried out on the same day prior to prostate biopsy and each maximum standardized uptake value (SUVmax) was compared with the pathological findings. The regions of interest (about 100 mm(2) small round) were placed at standard 6 points of the peripheral zone and 4 points in the apex of the transitional zone in cases that had undergone biopsy of the internal gland. We summed two scores if a specimen had inhomogeneous Gleason scores (e.g. GS 7; 4 + 3) and doubled the score when the Gleason score was the same (e.g. GS 8; 4 × 2). We divided the tumors into three groups. If the summed Gleason score of the specimens was 5 or less, they were grouped as NG (no grade with the Gleason score). If the summed Gleason score was 6 or 7, the tumors were defined as LG (low Gleason score group), and if the summed Gleason score was 8, 9 or 10, the tumors were classified as HG (high Gleason score group). The mean SUVmax was calculated and one-way analysis of variance or Kruskal-Wallis test and the Tukey post hoc test were performed for statistical comparisons. The capabilities of MET and FDG for diagnosing prostate cancer were evaluated through analysis of the area under the curve of the receiver operating characteristic (ROC) curve. The cut-off levels of SUVmax for the highest accuracy were determined by the results of the ROC analysis, and the sensitivity, specificity and accuracy were calculated. The PET images, obtained with Gemini TF PET/CT, allowed visual identification of anatomical locations within the prostate gland. Among the mean SUVmax of MET, FDG early phase and

  5. Intramuscular ganglia arising from the superior tibiofibular joint: CT and MR evaluation

    International Nuclear Information System (INIS)

    Bianchi, S.; Abdelwahab, I.F.; Kenan, S.; Zwass, A.; Ricci, G.; Palomba, G.

    1995-01-01

    To evaluate the role of magnetic resonance imaging (MRI) and computed tomography (CT) in the diagnosis of intramuscular ganglia (IMG) that arise from the superior tibiofibular joint (STFJ). Our series consisted of three men and three women. Four patients were studied by MRI, one by CT only, and two by both modalities. Contrast was used in one of the two patients studied by CT. MRI was obtained in at least two orthogonal planes to demonstrate the relation of the ganglia to STFJ. The MR and CT appearance of these ganglia was basically that of a well-defined soft tissue mass with low attenuation on CT images consistent with the presence of fluid. On MR studies, they had an isointense signal on T1-weighted images and a homogenous high-intensity signal on T2-weighted images. MRI demonstrated the attachment of these ganglia to the STFJ. CT and MRI were effective, noninvasive modalities in the evaluation of IMG. The imaging features on both modalities were consistent with the presence of fluid-containing lesions that had close proximity and were attached to the STFJ. The combination of location and the fluid consistency of these lesions facilitated the diagnosis. (orig.)

  6. UT-CT: A National Resource for Applications of High-Resolution X-ray Computed Tomography in the Geological Sciences

    Science.gov (United States)

    Carlson, W. D.; Ketcham, R. A.; Rowe, T. B.

    2002-12-01

    An NSF-sponsored (EAR-IF) shared multi-user facility dedicated to research applications of high-resolution X-ray computed tomography (CT) in the geological sciences has been in operation since 1997 at the University of Texas at Austin. The centerpiece of the facility is an industrial CT scanner custom-designed for geological applications. Because the instrument can optimize trade-offs among penetrating ability, spatial resolution, density discrimination, imaging modes, and scan times, it can image a very broad range of geological specimens and materials, and thus offers significant advantages over medical scanners and desktop microtomographs. Two tungsten-target X-ray sources (200-kV microfocal and 420-kV) and three X-ray detectors (image-intensifier, high-sensitivity cadmium tungstate linear array, and high-resolution gadolinium-oxysulfide radiographic line scanner) can be used in various combinations to meet specific imaging goals. Further flexibility is provided by multiple imaging modes: second-generation (translate-rotate), third-generation (rotate-only; centered and variably offset), and cone-beam (volume CT). The instrument can accommodate specimens as small as about 1 mm on a side, and as large as 0.5 m in diameter and 1.5 m tall. Applications in petrology and structural geology include measuring crystal sizes and locations to identify mechanisms governing the kinetics of metamorphic reactions; visualizing relationships between alteration zones and abundant macrodiamonds in Siberian eclogites to elucidate metasomatic processes in the mantle; characterizing morphologies of spiral inclusion trails in garnet to test hypotheses of porphyroblast rotation during growth; measuring vesicle size distributions in basaltic flows for determination of elevation at the time of eruption to constrain timing and rates of continental uplift; analysis of the geometry, connectivity, and tortuosity of migmatite leucosomes to define the topology of melt flow paths, for numerical

  7. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  8. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  9. Adaptive nonlocal means filtering based on local noise level for CT denoising

    International Nuclear Information System (INIS)

    Li, Zhoubo; Trzasko, Joshua D.; Lake, David S.; Blezek, Daniel J.; Manduca, Armando; Yu, Lifeng; Fletcher, Joel G.; McCollough, Cynthia H.

    2014-01-01

    Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the

  10. Technical Evaluation Report 41: WebCT: A major shift of emphasis

    Directory of Open Access Journals (Sweden)

    Kristine Thibeault

    2004-11-01

    Full Text Available The evaluation reports in this series usually feature several products at once. The current review, however, comes at a time when one of the most widely used (and expensive online learning management systems is undergoing a major change in its marketing strategy and corporate focus. WebCT is currently evolving to a new version (WebCT Vista, with much attendant discussion by distance education (DE users. The current review, as the others in this series, adds the DE student's perspective to this discussion. The review compares the existing WebCT Campus Edition with the new WebCT Vista, and examines some of the problems associated with the migration to Vista at the institutional level. A response to the report by the WebCT company is appended.

  11. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    International Nuclear Information System (INIS)

    Guy, Stephen D.; Tramontana, Adrian R.; Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A.; Lau, Eddie; Hicks, Rodney J.; Seymour, John F.

    2012-01-01

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [ 18 F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature ≥38 C and neutrophil count <500 cells/μl for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/μl (range 0-730 cells/μl). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  12. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Stephen D.; Tramontana, Adrian R. [Western Health, Department of Infectious Diseases, Private Bag, Footscray, Victoria (Australia); University of Melbourne, Parkville, Victoria (Australia); Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Infectious Diseases, Melbourne, Victoria (Australia); Lau, Eddie; Hicks, Rodney J. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Centre for Cancer Imaging, Melbourne, Victoria (Australia); Seymour, John F. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Haematology, Melbourne, Victoria (Australia)

    2012-08-15

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [{sup 18} F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature {>=}38 C and neutrophil count <500 cells/{mu}l for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/{mu}l (range 0-730 cells/{mu}l). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  13. 3D printing for orthopedic applications: from high resolution cone beam CT images to life size physical models

    Science.gov (United States)

    Jackson, Amiee; Ray, Lawrence A.; Dangi, Shusil; Ben-Zikri, Yehuda K.; Linte, Cristian A.

    2017-03-01

    With increasing resolution in image acquisition, the project explores capabilities of printing toward faithfully reflecting detail and features depicted in medical images. To improve safety and efficiency of orthopedic surgery and spatial conceptualization in training and education, this project focused on generating virtual models of orthopedic anatomy from clinical quality computed tomography (CT) image datasets and manufacturing life-size physical models of the anatomy using 3D printing tools. Beginning with raw micro CT data, several image segmentation techniques including thresholding, edge recognition, and region-growing algorithms available in packages such as ITK-SNAP, MITK, or Mimics, were utilized to separate bone from surrounding soft tissue. After converting the resulting data to a standard 3D printing format, stereolithography (STL), the STL file was edited using Meshlab, Netfabb, and Meshmixer. The editing process was necessary to ensure a fully connected surface (no loose elements), positive volume with manifold geometry (geometry possible in the 3D physical world), and a single, closed shell. The resulting surface was then imported into a "slicing" software to scale and orient for printing on a Flashforge Creator Pro. In printing, relationships between orientation, print bed volume, model quality, material use and cost, and print time were considered. We generated anatomical models of the hand, elbow, knee, ankle, and foot from both low-dose high-resolution cone-beam CT images acquired using the soon to be released scanner developed by Carestream, as well as scaled models of the skeletal anatomy of the arm and leg, together with life-size models of the hand and foot.

  14. Vocal cord paralysis due to extralaryngeal causes : evaluation with CT

    International Nuclear Information System (INIS)

    Lee, Jong Hwa; Mo, Jong Hyun; Moon, Sung Hee; Na, Dong Gyu; Byun, Hong Sik; Cho, Jae Min; Han, Boo Kyung; Son, Young Ik; Baek, Chung Whan

    1999-01-01

    To evaluate the use of CT in patients with vocal cord paralysis due to extralaryngeal causes, and to use CT for the assessment of extralaryngeal diseases causing vocal cord paralysis. We prospectively studied the results of CT in 41 patients with vocal cord paralysis in whom laryngoscopy revealed no laryngeal cause and physical examination demonstrated no definite extralaryngeal cause. The extralaryngeal cause of vocal cord palsy was determined after comprehensive clinical diagnosis. Enhanced CT scans were acquired from the skull base and continued to the level of the aorticopulmonary window. We used CT to assess the detection rate for extralaryngeal causes and to extimate the extent of extralaryngeal disease and the distribution of lesions. CT revealed that in 20 of 41 patients(49%) the extralarygeal causes of vocal paralysis were as follows : thyroid cancer(n=10), nodal disease(n=6), esophageal cancer(n=2), neurogenic tumor(n=1), aortic aneurysm(n=1). Lesions were located on the left side in 13 patients(65%), and in the tracheoesophageal groove in 15(75%). In patients with vocal cord paralysis in whom no definite lesion is seen on physical examination , CT could be a useful primary imaging method for the assessment of extralaryngeal causes

  15. In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models

    Directory of Open Access Journals (Sweden)

    Dawn Cavanaugh

    2004-01-01

    Full Text Available Micro-computed tomography (micro-CT is becoming an accepted research tool for the noninvasive examination of laboratory animals such as mice and rats, but to date, in vivo scanning has largely been limited to the evaluation of skeletal tissues. We use a commercially available micro-CT device to perform respiratory gated in vivo acquisitions suitable for thoracic imaging. The instrument is described, along with the scan protocol and animal preparation techniques. Preliminary results confirm that lung tumors as small as 1 mm in diameter are visible in vivo with these methods. Radiation dose was evaluated using several approaches, and was found to be approximately 0.15 Gy for this respiratory-gated micro-CT imaging protocol. The combination of high-resolution CT imaging and respiratory-gated acquisitions appears well-suited to serial in vivo scanning.

  16. Filtered backprojection proton CT reconstruction along most likely paths

    Energy Technology Data Exchange (ETDEWEB)

    Rit, Simon; Dedes, George; Freud, Nicolas; Sarrut, David; Letang, Jean Michel [Universite de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Universite Lyon 1, Centre Leon Berard, 69008 Lyon (France)

    2013-03-15

    Purpose: Proton CT (pCT) has the potential to accurately measure the electron density map of tissues at low doses but the spatial resolution is prohibitive if the curved paths of protons in matter is not accounted for. The authors propose to account for an estimate of the most likely path of protons in a filtered backprojection (FBP) reconstruction algorithm. Methods: The energy loss of protons is first binned in several proton radiographs at different distances to the proton source to exploit the depth-dependency of the estimate of the most likely path. This process is named the distance-driven binning. A voxel-specific backprojection is then used to select the adequate radiograph in the distance-driven binning in order to propagate in the pCT image the best achievable spatial resolution in proton radiographs. The improvement in spatial resolution is demonstrated using Monte Carlo simulations of resolution phantoms. Results: The spatial resolution in the distance-driven binning depended on the distance of the objects from the source and was optimal in the binned radiograph corresponding to that distance. The spatial resolution in the reconstructed pCT images decreased with the depth in the scanned object but it was always better than previous FBP algorithms assuming straight line paths. In a water cylinder with 20 cm diameter, the observed range of spatial resolutions was 0.7 - 1.6 mm compared to 1.0 - 2.4 mm at best with a straight line path assumption. The improvement was strongly enhanced in shorter 200 Degree-Sign scans. Conclusions: Improved spatial resolution was obtained in pCT images with filtered backprojection reconstruction using most likely path estimates of protons. The improvement in spatial resolution combined with the practicality of FBP algorithms compared to iterative reconstruction algorithms makes this new algorithm a candidate of choice for clinical pCT.

  17. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  18. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  19. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    OpenAIRE

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki

    2015-01-01

    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images fr...

  20. The usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region

    International Nuclear Information System (INIS)

    Grzesiakowska, U.; Tacikowska, M.; Krajewski, R.; Starosciak, S.; Smorczewska, M.; Wiszniewska-Rawlik, D.

    2005-01-01

    The aim of the study was to determine the usefulness of CT and MR imaging in the preoperative evaluation of neoplasms of the craniofacial region. All the patients were treated surgically. CT and/or MR imaging was done in every patient for preoperative evaluation of soft tissue infiltration, destruction of bone structures, and metastasis of lymph nodes of the head and neck. The results of these imagings were compared with surgical evaluations and microscopic examination of postoperative specimens. Both CT and MR imaging have high accuracy in evaluating soft tissue infiltration. CT imaging is much better than MR in evaluating bony destruction. MR imaging is better in evaluating recurrent tumors, in which CT has very low specificity. MR imaging is the only method for evaluating infiltration of the central nervous system.The authors propose the following diagnostic algorithm: CT imaging for initial evaluation before treatment, MR imaging in suspected cases of infiltration of the central nervous system, and MR imaging in recurrent tumors after surgical and radiation treatment. (author)

  1. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  2. Lumbar CT findings of patients with low back pain

    International Nuclear Information System (INIS)

    Lee, Yong Chul; Kim, Yang Soo; Kim, Kyun Sang

    1986-01-01

    Low back pain is probably the second most common disease entity to upper respiratory infection in developed country. We were missing at least 50% of the pathologic conditions by using conventional diagnostic modalities in low back pain. They did tell us nothing or little about facet abnormalities, lateral recesses, vertebral canal and soft tissue surrounding lumbar spines. High resolutional CT has been the biggest turning point in the diagnosis and management of low back pain. CT make a contribution to reducing the morbidity and probably the cost of evaluating patients with low back pain, and to increasing diagnostic accuracy. We observed 100 cases of lumbar CT using TCT 80A scanner for the evaluation of low back pain during the period from Apr. 1985 to Sept. 1985 at Chung-Ang University Hospital. Lumbar CT scan reveals high-positive findings (98%) in low back pain patients. Common low back disorders in CT are disc bulging (53%), herniated nucleus pulposus (32%), degenerative arthritis in posterior facet joints (27%), spinal stenosis (20%) and postoperative spines (15%). Uncommon low back disorders in CT are compression fracture of vertebral bodies, spondylolysis or spondylolisthesis, tropism, transitional vertebra, Scheueman's disease, limbic fracture, transverse process or articular process fracture, sacroiliac joint subluxation, conjoined nerve root and meningocele.

  3. Lumbar CT findings of patients with low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Chul; Kim, Yang Soo; Kim, Kyun Sang [Chung-Ang University, Seoul (Korea, Republic of)

    1986-04-15

    Low back pain is probably the second most common disease entity to upper respiratory infection in developed country. We were missing at least 50% of the pathologic conditions by using conventional diagnostic modalities in low back pain. They did tell us nothing or little about facet abnormalities, lateral recesses, vertebral canal and soft tissue surrounding lumbar spines. High resolutional CT has been the biggest turning point in the diagnosis and management of low back pain. CT make a contribution to reducing the morbidity and probably the cost of evaluating patients with low back pain, and to increasing diagnostic accuracy. We observed 100 cases of lumbar CT using TCT 80A scanner for the evaluation of low back pain during the period from Apr. 1985 to Sept. 1985 at Chung-Ang University Hospital. Lumbar CT scan reveals high-positive findings (98%) in low back pain patients. Common low back disorders in CT are disc bulging (53%), herniated nucleus pulposus (32%), degenerative arthritis in posterior facet joints (27%), spinal stenosis (20%) and postoperative spines (15%). Uncommon low back disorders in CT are compression fracture of vertebral bodies, spondylolysis or spondylolisthesis, tropism, transitional vertebra, Scheueman's disease, limbic fracture, transverse process or articular process fracture, sacroiliac joint subluxation, conjoined nerve root and meningocele.

  4. CT-sialographic evaluation of 19 cases of alivary gland tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tadashi [Komoro Kousei General Hospital, Nagano (Japan)

    1999-09-01

    Sixteen patients with parotid gland tumors and 3 patients with submandibular gland tumors were evaluated by CT sialography. The 19 patients were 5 to 78 years old, mean age: 57.3 years. CT sialography was performed preoperatively, and postoperative histological examination indicated that the tumors were benign in 13, a cyst in 1, malignant tumors in 4, and a malignant lymphoma in 1 patient. The tumorous lesion detection rate by CT sialography was 100%. The major duct was visualized in all patients, and the examination was informative about the special relationship between the tumor and the facial nerve. No sign of malignancy was noted in an epithelialmyoepithelial carcinoma of 10 mm in diameter on CT sialography. In 2 patients adhesion to surrounding tissues observed intraoperatively was judged to be benign tumors by CT sialography. The marginal morphology of the tumor and the presence or absence of low density areas and punctuate leakage in the interior of the tumor were useful for the judgement of malignancy of salivary gland tumors. CT sialography, which provides diverse information on the location and morphology of the tumor, should be performed early for the diagnosis of salivary gland tumors. (author)

  5. TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

    International Nuclear Information System (INIS)

    Hua, C.

    2015-01-01

    This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI

  6. TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C. [St. Jude Childrens Research Hospital (United States)

    2015-06-15

    This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI

  7. An experimental study on the radiation-induced injury of the rabbit lung: Correlation of soft-tissue radiograph and high- resolution CT findings with pathologic findings

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Nam, Kyung Jin; Park, Byeoung Ho; Jeong, Jin Sook; Lee, Hyung Sik

    1994-01-01

    To describe soft-tissue radiographic and high-resolution CT findings of radiation-induced lung injury of rabbit over time and to correlate them with pathologic findings. 15 rabbits were irradiated in the right lung with one fracture of 2000 cGy. After 4, 6, 12, 20, 24 weeks 3 rabbits in each group were sacrificed and soft-tissue radiographs and high-resolution CT of their lung tissue were obtained. Radiological findings were correlated with pathologic findings. On soft-tissue radiogram, radiation pneumonitis shown as consolidation with air- bronchogram occurred in 3 cases after 6 weeks , and in 1 case after 12 weeks of irradiation. In addition, pneumonic consolidation with adjacent pleural contraction was seen in 2 cases after 12 weeks of irradiation. Fibrotic changes indicated by decreased volume occurred after 20 weeks and combined bronchiectatic change and bronchial wall thickening appeared after 20 weeks(N=1), and 24 weeks(N=3). HRCT findings of radiation pneumonitis were homogeneous, increased attention after 4 weeks(N=3), 6 and 12 weeks(each N=1), patchy consolidation after 6 and 12 weeks(each N=2), discrete consolidation after 12, 20 and 24 weeks(each N=1) and solid consolidation after 20 and 24 weeks(each N=2). Pathologically radiation pneumonitis and pulmonary congestion were seen after 4 and 6 weeks. After 6 weeks, collagen and reticulin fibers were detected along alveolar wall. Mixed radiation pneumonitis and fibrosis were detected after 12 weeks. 20 weeks after irradiation, fibrosis was well defined in interstitium and in 24 weeks, decreased number of alveoli and thickening of bronchial wall were defined. Radiation pneumonitis was provoked 4 weeks after irradiation on rabbit lung and progressed into radiation fibrosis 20 weeks after irradiation on soft-tissue radiographs and high-resolution CT. High-resolution CT is more precise in detecting early radiation pneumonitis and detailed pathologic findings

  8. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  9. Correlation between CT and tympanogram in secretory otitis media

    International Nuclear Information System (INIS)

    Kobayashi, Toshimitsu; Sakurai, Tokio; Taniguchi, Kazuhiko; Takahashi, Kuniaki; Ikeda, Katsuhisa; Kawamoto, Kazutomo.

    1984-01-01

    In an attempt to evaluate the feasibility of the tympanometry in detecting the middle ear effusion (MEE) in secretory otitis media (SOM) in childhood, the findings of the computed tomography (CT) were evaluated whether they were compatible with that of tympanometry in 27 cases (51 ears) of SOM. Tympanometry (tympanogram, static compliance measurement and stapedial reflex test), pure tone audiometry and high resolution CT were performed sequentially, and the CT findings were compared with the results of the other tests. The conclusions obtained were summarized as follows. 1. Among the tests performed, tympanogram appeared to be the most reliable measure in detection of MEE. 2. Fifteen ears out of 16 with type B tympanograms and 6 ears out of 15 with type C 2 tympanograms, were diagnosed by CT as having MEE. MEE occupied the entire middile ear space in most ears with type B tympanograms. By contrast, in the ears with type C 2 tympanograms, air containing space of varying size were always observed even in the ears with MEE. (author)

  10. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    International Nuclear Information System (INIS)

    Demirkazik, Figen Basaran; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P 1 (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV 1 (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry

  11. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  12. Quantitative comparison of PET performance—Siemens Biograph mCT and mMR

    Energy Technology Data Exchange (ETDEWEB)

    Karlberg, Anna M.; Sæther, Oddbjørn [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Eikenes, Live [Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Postbox 8905, 7491 Trondheim (Norway); Goa, Pål Erik [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Department of Physics, Norwegian University of Science and Technology, Trondheim (Norway)

    2016-02-25

    Integrated clinical whole-body PET/MR systems were introduced in 2010. In order to bring this technology into clinical usage, it is of great importance to compare the performance with the well-established PET/CT. The aim of this study was to evaluate PET performance, with focus on image quality, on Siemens Biograph mMR (PET/MR) and Siemens Biograph mCT (PET/CT). A direct quantitative comparison of the performance characteristics between the mMR and mCT system was performed according to National Electrical Manufacturers Association (NEMA) NU 2-2007 protocol. Spatial resolution, sensitivity, count rate and image quality were evaluated. The evaluation was supplemented with additional standardized uptake value (SUV) measurements. The spatial resolution was similar for the two systems. Average sensitivity was higher for the mMR (13.3 kcps/MBq) compared to the mCT system (10.0 kcps/MBq). Peak noise equivalent count rate (NECR) was slightly higher for the mMR (196 kcps @ 24.4 kBq/mL) compared to the mCT (186 kcps @ 30.1 kBq/mL). Scatter fractions in the clinical activity concentration range yielded lower values for the mCT (34.9 %) compared to those for the mMR (37.0 %). Best image quality of the systems resulted in approximately the same mean hot sphere contrast and a difference of 19 percentage points (pp) in mean cold contrast, in favour of the mCT. In general, point spread function (PSF) increased hot contrast and time of flight (TOF) increased both hot and cold contrast. Highest hot contrast for the smallest sphere (10 mm) was achieved with the combination of TOF and PSF on the mCT. Lung residual error was higher for the mMR (22 %) than that for the mCT (17 %), with no effect of PSF. With TOF, lung residual error was reduced to 8 % (mCT). SUV was accurate for both systems, but PSF caused overestimations for the 13-, 17- and 22-mm spheres. Both systems proved good performance characteristics, and the PET image quality of the mMR was close to that of the mCT

  13. CT anatomy of the spine

    International Nuclear Information System (INIS)

    Haughton, V.M.; Williams, A.L.

    1980-01-01

    Effective CT scanning of the spine requires gantry opening greater than 50 cm, spatial resolution of less than 1 mm, contrast resolution of better than 0.5%, and a method for exact localization and selection of cut levels. With a suitable scanner, excellent images of the intervertebral disc, dural sac, spinal cord, facet joints, ligamentum flavum, and epidural veins can be obtained. The purpose of this report is to describe the normal CT appearance of the spinal soft tissues. (orig.) [de

  14. An experimental study of exogenous lipoid pneumonia : sequential changes in high-resolution CT and MR findings

    International Nuclear Information System (INIS)

    Kim, Kyeong Ah; Kang, Eun Young; Kim, Dae Hyun; Park, Sang Woo; Choi, Jeong Cheol; Kim, Ae Ree; Kim, Han Kyum; Cha, In Ho

    1999-01-01

    To evaluate sequential changes in high-resolution CT(HRCT) and MR findings of exogenous lipoid pneumonia in rabbits and to compare the radiologic and histopathologic findings. A single endobronchial administration of shark liver oil(0.5 or 1 ml/kg of body weight) was given to 25 rabbits. HRCT scans were obtained immediately(n=17), at 1 day(n=14), 3 days(n=10), 1 week(n=15), 2 weeks(n=10), 4 weeks(n=9), 6 weeks(n=5), 8 weeks(n=6), 10 weeks(n=4), 12 weeks(n=2), 14 weeks(n=3), and 16 weeks(n=2) after administration. Changes in distribution, extent, and attenuation were assessed on HRCT scans. MR scans were obtained immediately(n=12), at 1 day(n=9), 3 days(n=9), 1 week(n=15), 2 weeks(n=9), 4 weeks(n=11), 6 weeks(n=5), 8 weeks(n=7), 10 weeks(n=3), 14 weeks(n=3), and at 16 weeks(n=2) after administration. Changes in distribution, extent, and signal intensity were assessed on MR scans. In 16 rabbits, CT and MR findings were compared with histopatholo-gic findings obtained in the same plane. HRCT findings included consolidation with air-bronchogram, ground-glass attenuation and fat attenuation within the lesion at earlier stages(immediate-2 weeks). The extent of lesions was greatest at 1 week, and was then seen to gradually decrease on follow-up CT scans. T1-weighted MR images(T1WI) showed high or intermediate signal intensity(SI) at earlier stages and intermediate SI at later stages, while T2-weighted MR images(T2WI) showed high SI at both earlier and later stages. Histopathologic correlation showed that ground-glass attenuation and consolidation on HRCT reflected intraalveolar lipid-laden macrophages, cuboidal metaplasia of alveolar epithelial cells, and alveolar septal widening with inflammatory cell infiltration. Maximal infiltration of oil in the lung correlated closely with the peak low-attenuation seen on CT scans and the high signal intensity seen on T1WI. Shark liver oil-induced exogenous lipoid pneumonia in rabbits is reliably diagnosed by HRCT and MR during

  15. Gamma-ray CT from incomplete projections for two-phase pipe flow.

    Science.gov (United States)

    Xin, S; Wang, H X

    2017-02-01

    A low-energy low-dose γ-ray computed tomography (CT) system used in the gas-liquid two-phase pipe flow measurement has been studied at Tianjin University in recent years. The γ-ray CT system, having a third-generation X-ray CT scanning configuration, is comprised of one 300mCi 241 Am source and 17 CdZnTe detector units and achieves a spatial image resolution of about 7 mm. It is primarily intended to measure the two-phase pipe flow and provide improvement suggestions for industrial CT system. Recently we improve the design for image reconstruction from incomplete projection to optimize the scanning parameters and reduce the radiation dose. First, tomographic problem from incomplete projections is briefly described. Next, a system structure and a hardware circuit design are listed and explained, especially on time parameter setting of the pulse shaper. And then a detailed system analysis is provided in Section II, mainly focusing on spatial resolution, temporal resolution, system noise, and imaging algorithm. Finally, we carry on necessary static and dynamic experiments in a full scan (360°) and two sets of partial scan reconstruction tests to determine the feasibility of this γ-ray CT system for reconstructing the images from insufficient projections. And based on an A-variable algebraic reconstruction technique method, a specially designed algorithm, we evaluate the system performance and noise level of this CT system working quantitatively and qualitatively. Results of dynamic test indicate that the acceptable results can be acquired using a multi-source γ-ray CT system with the same parameters when the flow rate is less than 0.04 m/s and the imaging speed is slower than 33 frames/s.

  16. Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

    Science.gov (United States)

    Cao, Qian; Sisniega, Alejandro; Brehler, Michael; Stayman, J Webster; Yorkston, John; Siewerdsen, Jeffrey H; Zbijewski, Wojciech

    2018-01-01

    Quantitative assessment of trabecular bone microarchitecture in extremity cone-beam CT (CBCT) would benefit from the high spatial resolution, low electronic noise, and fast scan time provided by complementary metal-oxide semiconductor (CMOS) x-ray detectors. We investigate the performance of CMOS sensors in extremity CBCT, in particular with respect to potential advantages of thin (CMOS x-ray detector incorporating the effects of CsI:Tl scintillator thickness was developed. Simulation studies were performed using nominal extremity CBCT acquisition protocols (90 kVp, 0.126 mAs/projection). A range of scintillator thickness (0.35-0.75 mm), pixel size (0.05-0.4 mm), focal spot size (0.05-0.7 mm), magnification (1.1-2.1), and dose (15-40 mGy) was considered. The detectability index was evaluated for both CMOS and a-Si:H flat-panel detector (FPD) configurations for a range of imaging tasks emphasizing spatial frequencies associated with feature size aobj. Experimental validation was performed on a CBCT test bench in the geometry of a compact orthopedic CBCT system (SAD = 43.1 cm, SDD = 56.0 cm, matching that of the Carestream OnSight 3D system). The test-bench studies involved a 0.3 mm focal spot x-ray source and two CMOS detectors (Dalsa Xineos-3030HR, 0.099 mm pixel pitch) - one with the standard CsI:Tl thickness of 0.7 mm (C700) and one with a custom 0.4 mm thick scintillator (C400). Measurements of modulation transfer function (MTF), detective quantum efficiency (DQE), and CBCT scans of a cadaveric knee (15 mGy) were obtained for each detector. Optimal detectability for high-frequency tasks (feature size of ~0.06 mm, consistent with the size of trabeculae) was ~4× for the C700 CMOS detector compared to the a-Si:H FPD at nominal system geometry of extremity CBCT. This is due to ~5× lower electronic noise of a CMOS sensor, which enables input quantum-limited imaging at smaller pixel size. Optimal pixel size for high-frequency tasks was CMOS

  17. PET/CT in staging and treatment response evaluation in lymphomas

    International Nuclear Information System (INIS)

    Bochev, P.

    2015-01-01

    Full text:The introduction of positron emission tomography (PET) and especially PET/CT with FDG in 2001 resulted in new concepts of overall management of patients with lymphoma and changed significantly the staging process and treatment response assessment. The considerable amount of literature and clinical trial data allowed leading cancer organizations like NCCN to incorporate in their current guidelines FDG-PET as a sole imaging modality in the management of Hodgkin‘s lymphoma, and an essential one in the management of FDG avid non-Hodgkin lymphoma (where indications vary based on particular histology). Main indications of FDG PET/CT in lymphoma are initial staging, restaging upon completion of therapy (EOT PET) and treatment response assessment. While staging with FDG and EOT PET restaging alone or combined with CECT have a straight-forward advantage over CT in evaluating small and borderline sized lymph nodes, bone marrow involvement and residual masses, treatment response assessment is rather challenging. By now and after long term trial evaluations, the response assessment is based on a visual assessment five point scale – Deauvillae criteria for response evaluation in HD and combined lugano criteria for NHL. The scale defines PET negative and PET positive cases as a presentation of responders versus non-responders which directly affects management. Although ESMO restricts the use of FDG-PET response evaluation in clinical trials only, NCCN go further, and bases its treatment recommendations on FDG-PET (Interim PET). Nowadays PET/CT is extensively used also in radiotherapy planning, which, in lymphoma patients include initial staging scans on a flat table, in order to assure similar position of future involved sites RT. Despite the extensive use of FDG with the above mentioned indications, neither evidence based guidelines, nor routine clinical practice could recommend follow up of lymphoma patients with FDG-PET. An exception could be made for ositive or

  18. Noninvasive assessment of pulmonary vascular and airway response to physiologic stimuli with high-resolution CT

    International Nuclear Information System (INIS)

    Herold, C.J.; Wetzel, R.C.; Herold, S.M.; Martin, L.; Zerhouni, E.A.; Robotham, J.

    1990-01-01

    This paper reports on reactivity of pulmonary vasculature under various stimuli studied invasively with perfused isolated lung models. We used high- resolution CT (HRCT) to demonstrate noninvasively the effects of hypoxia and volume variation on pulmonary circulation and airways. Five anesthetized and ventilated pigs were examined with HRCT (10 contiguous 2-mm sections through the lower lobes) during varying oxygen tensions and intravascular volume states. Blood pressures, pulmonary artery pressures, blood gas levels, and cardiac indexes (thermodilution) were measured. HRCT scans were digitized, and vessel and airway areas were determined with use of a computer edging process

  19. PET-CT in the evaluation of sarcomas of soft tissues

    International Nuclear Information System (INIS)

    Serna M, J.A.; Quiroz C, O.; Sanchez C, N.; Diaz V, G.

    2007-01-01

    18 F-FDG PET-CT is an image modality of great utility in the evaluation of primary or recurrent lesions of soft tissues. It is necessary to determine the cost-benefit of the different image modalities, although one waits that by means of a better diagnostic, statification and the determination of the grade of malignancy, the PET-CT nowadays can reduce the cost and the complications of the invasive diagnostic methods. (Author)

  20. Novel Influenza A (H1N1) Virus Infection in Children: Chest Radiographic and CT Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Min Jeong; Lee, Young Seok; Lee, Jee Young; Lee, Kun Song [Dankook University College of Medicine, Dankook University Hospital, Cheonan (Korea, Republic of)

    2010-12-15

    The purpose of this study was to evaluate the chest radiographic and CT findings of novel influenza A (H1N1) virus infection in children, the population that is more vulnerable to respiratory infection than adults. The study population comprised 410 children who were diagnosed with an H1N1 infection from August 24, 2009 to November 11, 2009 and underwent chest radiography at Dankook University Hospital in Korea. Six of these patients also underwent chest CT. The initial chest radiographs were classified as normal or abnormal. The abnormal chest radiographs and high resolution CT scans were assessed for the pattern and distribution of parenchymal lesions, and the presence of complications such as atelectasis, pleural effusion, and pneumomediastinum. The initial chest radiograph was normal in 384 of 410 (94%) patients and abnormal in 26 of 410 (6%) patients. Parenchymal abnormalities seen on the initial chest radiographs included prominent peribronchial marking (25 of 26, 96%), consolidation (22 of 26, 85%), and ground-glass opacities without consolidation (2 of 26, 8%). The involvement was usually bilateral (19 of 26, 73%) with the lower lung zone predominance (22 of 26, 85%). Atelectasis was observed in 12 (46%) and pleural effusion in 11 (42%) patients. CT (n = 6) scans showed peribronchovascular interstitial thickening (n = 6), ground-glass opacities (n = 5), centrilobular nodules (n = 4), consolidation (n = 3), mediastinal lymph node enlargement (n = 5), pleural effusion (n = 3), and pneumomediastinum (n = 3). Abnormal chest radiographs were uncommon in children with a swine-origin influenza A (H1N1) virus (S-OIV) infection. In children, H1N1 virus infection can be included in the differential diagnosis, when chest radiographs and CT scans show prominent peribronchial markings and ill-defined patchy consolidation with mediastinal lymph node enlargement, pleural effusion and pneumomediastinum

  1. Novel Influenza A (H1N1) Virus Infection in Children: Chest Radiographic and CT Evaluation

    International Nuclear Information System (INIS)

    Choi, Min Jeong; Lee, Young Seok; Lee, Jee Young; Lee, Kun Song

    2010-01-01

    The purpose of this study was to evaluate the chest radiographic and CT findings of novel influenza A (H1N1) virus infection in children, the population that is more vulnerable to respiratory infection than adults. The study population comprised 410 children who were diagnosed with an H1N1 infection from August 24, 2009 to November 11, 2009 and underwent chest radiography at Dankook University Hospital in Korea. Six of these patients also underwent chest CT. The initial chest radiographs were classified as normal or abnormal. The abnormal chest radiographs and high resolution CT scans were assessed for the pattern and distribution of parenchymal lesions, and the presence of complications such as atelectasis, pleural effusion, and pneumomediastinum. The initial chest radiograph was normal in 384 of 410 (94%) patients and abnormal in 26 of 410 (6%) patients. Parenchymal abnormalities seen on the initial chest radiographs included prominent peribronchial marking (25 of 26, 96%), consolidation (22 of 26, 85%), and ground-glass opacities without consolidation (2 of 26, 8%). The involvement was usually bilateral (19 of 26, 73%) with the lower lung zone predominance (22 of 26, 85%). Atelectasis was observed in 12 (46%) and pleural effusion in 11 (42%) patients. CT (n = 6) scans showed peribronchovascular interstitial thickening (n = 6), ground-glass opacities (n = 5), centrilobular nodules (n = 4), consolidation (n = 3), mediastinal lymph node enlargement (n = 5), pleural effusion (n = 3), and pneumomediastinum (n = 3). Abnormal chest radiographs were uncommon in children with a swine-origin influenza A (H1N1) virus (S-OIV) infection. In children, H1N1 virus infection can be included in the differential diagnosis, when chest radiographs and CT scans show prominent peribronchial markings and ill-defined patchy consolidation with mediastinal lymph node enlargement, pleural effusion and pneumomediastinum

  2. Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging

    International Nuclear Information System (INIS)

    Meyer, Mathias; Haubenreisser, Holger; Schoenberg, Stefan O.; Henzler, Thomas; Raupach, Rainer; Schmidt, Bernhard; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Lietzmann, Florian; Schad, Lothar R.

    2015-01-01

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm 2 removesthe necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63 %/39 % lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. (orig.)

  3. Multicenter Comparison of Contrast-Enhanced FDG PET/CT and 64-Slice Multi-Detector-Row CT for Initial Staging and Response Evaluation at the End of Treatment in Patients With Lymphoma.

    Science.gov (United States)

    Gómez León, Nieves; Delgado-Bolton, Roberto C; Del Campo Del Val, Lourdes; Cabezas, Beatriz; Arranz, Reyes; García, Marta; Cannata, Jimena; González Ortega, Saturnino; Pérez Sáez, Mª Ángeles; López-Botet, Begoña; Rodríguez-Vigil, Beatriz; Mateo, Marta; Colletti, Patrick M; Rubello, Domenico; Carreras, José L

    2017-08-01

    To compare staging correctness between contrast-enhanced FDG PET/ceCT and 64-slice multi-detector-row CT (ceCT64) for initial staging and response evaluation at the end of treatment (EOT) in patients with Hodgkin lymphoma, diffuse large B cell lymphoma (DLBCL), and follicular lymphoma. This prospective study compared initial staging and response evaluation at EOT. One hundred eighty-one patients were randomly assigned to either ceCT64 or FDG PET/ceCT. A nuclear medicine physician and a radiologist read FDG PET/ceCT scans independently and achieved post hoc consensus, whereas another independent radiologist interpreted ceCT64 separately. The reference standard included all clinical information, all tests, and follow-up. Ethics committees of the participating centers approved the study, and all participants provided written consent. Ninety-one patients were randomized to ceCT64 and 90 to FDG PET/ceCT; 72 had Hodgkin lymphoma, 72 had DLBCL, and 37 had follicular lymphoma. There was excellent correlation between the reference standard and initial staging for both FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84), although evaluation of the response at EOT was excellent only for FDG PET/ceCT (κ = 0.91). Our study demonstrated satisfactory agreement between FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84) in initial staging compared with the reference standard (P = 0.16). Response evaluation at EOT with FDG PET/ceCT (κ = 0.91) was superior compared with ceCT64 (κ = 0.307) (P < 0.001).

  4. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    International Nuclear Information System (INIS)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi; Morikage, Noriyasu; Sano, Yuichi; Suga, Kazuyoshi

    2013-01-01

    Background: Dual-energy perfusion CT (DE p CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE p CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE p CT using a 64-slice dual-source CT. DE p CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V 120 ), 1-15 HU (V 15 ), 1-10 HU (V 10 ), and 1-5 HU (V 5 ). Each relative ratio per V 120 was expressed as the %V 15 , %V 10 , and %V 5 . Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V 15 , V 10 , V 5 , %V 15 , %V 10 , and %V 5 were also significantly higher than those without IPC (P = 0.001). %V 5 had a better correlation with D-dimer (r = 0.30, P p CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE

  5. Combined 18F-NaF and 18F-FDG PET/CT in the Evaluation of Sarcoma Patients.

    Science.gov (United States)

    Jackson, Tatianie; Mosci, Camila; von Eyben, Rie; Mittra, Erik; Ganjoo, Kristen; Biswal, Sandip; Gambhir, Sanjiv Sam; Iagaru, Andrei

    2015-09-01

    The combined administration of F-NaF and F-FDG in a single PET/CT scan has the potential to improve patient convenience and cancer detection. Here we report the use of this approach for patients with sarcomas. This is a retrospective review of 21 patients (12 men, 9 women; age, 19-66 years) with biopsy-proven sarcomas who had separate F-NaF PET/CT, F-FDG PET/CT, and combined F-NaF/F-FDG PET/CT scans for evaluation of malignancy. Two board-certified nuclear medicine physicians and 1 board-certified musculoskeletal radiologist were randomly assigned to review the scans. Results were analyzed for sensitivity and specificity, using linear regression and receiver operating characteristics. A total of 13 patients had metastatic disease on F-NaF PET/CT, F-FDG PET/CT, and combined F-NaF/F-FDG PET/CT. Skeletal disease was more extensive on the F-NaF PET/CT scan than on the F-FDG PET/CT in 3 patients, whereas in 1 patient, F-FDG PET/CT showed skeletal disease and the F-NaF PET/CT was negative. Extraskeletal lesions were detected on both F-FDG and combined F-NaF/F-FDG PET/CT in 20 patients, with 1 discordant finding in the lung. The combined F-NaF/F-FDG PET/CT scan allows for accurate evaluation of sarcoma patients. Further evaluation of this proposed imaging modality is warranted to identify the most suitable clinical scenarios, including initial treatment strategy and evaluation of response to therapy.

  6. The role of pneumothorax CT for the evaluation of aortic invasion by lung cancer

    International Nuclear Information System (INIS)

    Yokoi, Kohei; Mori, Kiyoshi; Miyazawa, Naoto; Magota, Seizo; Honda, Kazuyoshi; Sasagawa, Michizo

    1987-01-01

    To improve the accuracy of T3 diagnosis in lung cancer, Pneumothorax CT was carried out in four patients having diagnosis of plain CT and enhanced CT. Both plain and enhanced CT demonstrated obliteration of low density zone between tumor and the aorta in all cases. In three of four cases, Pneumothorax CT, however, demonstrated free air space where tumor was evaluated to be invaded. Remaining one presented the loss of such free air space even by Pneumothorax CT and was made the diagnosis of aortic invasion, which was confirmed by surgicopathological finding. Pneumothorax CT is useful for the diagnosis of ruling out tumor invasion to the aorta. (author)

  7. What is the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after CT?

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Kwanseop [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)], E-mail: kwanseop@hallym.or.kr; Kim, Min-Jeong; Yoon, Hoi Soo; Jeon, Eui Yong; Koh, Sung Hye [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Min, Kwangseon [Department of Pathology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Choi, Dongil [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (Korea, Republic of)

    2010-04-15

    The objective of our study was to estimate the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after abdominoplevic CT. A total of 104 patients initially underwent abdominopelvic CT before appendix US due to acute abdominal pain. All CT examinations were evaluated retrospectively for the presence of acute appendicitis. The findings of appendix on CT were classified into five categories (definite appendicitis, probably appendicitis, equivocal CT findings for diagnosis of appendicitis, probably not appendicitis, and normal looking appendix). Appendix US images and their radiologic reports were also evaluated retrospectively. Then, CT and US findings were correlated with clinical or pathologic diagnosis. Three all patients with definite appendicitis initially on CT again showed US findings of appendicitis. In the 32 patients of probably appendicitis on CT, US showed normal looking appendix in seven patients (21.8%, 7 of 32) who improved with medical treatment and discharged. In the 16 patients of equivocal CT findings for diagnosis of appendicitis, US showed appendicitis in seven patients (43.8%, 7 of 16) and normal looking appendix in nine patients. In the 12 patients of probably not appendicitis on CT, US showed acute appendicitis in two patients (16.7%, 2 of 12). In the 41 patients of normal looking appendix on CT, US showed acute appendicitis in five patients (12.2%, 5 of 41). US reevaluation enables us to avoid misdiagnosis of appendicitis on CT and improve diagnostic accuracy of acute appendicitis.

  8. Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

    Science.gov (United States)

    Cho, Hyo-Min; Barber, William C.; Ding, Huanjun; Iwanczyk, Jan S.; Molloi, Sabee

    2014-01-01

    Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A109Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm2) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution

  9. Two- and three-dimensional CT evaluation of sacral and pelvic anomalies

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Magid, D.

    1988-01-01

    Pelvic anomalies are difficult to evaluate with standard techniques. Detailed knowledge of the existing pelvic structures and musculature is essential for successful repair. The authors evaluated 12 patients with complex malformations of the pelvis using two- and three-dimensional imaging. The anomalies included bladder exstrophy (n = 4), cloacal exstrophy (n = 1), duplicated and absent sacrum (n = 3), myelomeningoceles (n = 2), and diastrophic dwarfism (n = 2). The two-dimensional images consisted of sequential coronal and sagittal reconstructions that could be reviewed dynamically on screen. Three-dimensional images were generated on the Pixar imaging computer with use of volumetric rendering. Two- and three-dimensional CT proved complementary in the evaluation of pelvic anomalies, providing optimal information from transaxial CT data

  10. Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyun; Chang, Yun Woo; Hwang, Jung Hwa; Kim, Hyung Hwan; Lee, Eun Hye; Yang, Seung Boo

    2013-01-01

    To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy.

  11. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  12. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    International Nuclear Information System (INIS)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B.; Screaton, Nicholas J.

    2009-01-01

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  13. PET-CT in the evaluation of metastatic breast cancer

    International Nuclear Information System (INIS)

    Sullivan, A.M.; Fulham, M.J.

    2005-01-01

    A 44-year-old woman underwent two PET-CT scans for the evaluation of metastatic breast cancer. A radical left mastectomy with axillary dissection (1 of 43 nodes positive) followed by chemotherapy, was performed in 1998. She represented in October 2003 with a left supraclavicular fossa mass. This was confirmed to be recurrent breast cancer on FNAB. She was considered for a radical neck dissection and the surgeon requested a PET scan. Other imaging at this time included a normal bone scan and CT brain. CT neck/chest/abdomen/pelvis showed soft tissue thickening in the left lower neck. The PET-CT scan showed multiple glucose avid lesions in the sternum, mediastinum and neck lymph nodes as well as a small lesion in the proximal left femur consistent with extensive metastatic disease. Surgery was cancelled and Femara chemotherapy commenced. Femara was stopped in March 2004 and the patient began alternative therapies. In October 2004 she presented to her surgeon with new back and chest pain. CT of the neck/chest/abdomen/pelvis showed a soft tissue mass in the upper sternum and a lymph node at the base of the neck highly suspicious for metastatic disease. There were also 2 suspicious lung nodules and a lesion in the proximal left femur reported as an osteoid osteoma. Wholebody PET-CT scans were performed on a Siemens LSO Biograph, 60mins after the injection of 350Mbq of Fl 8-Fag, with arms at the patient's side and head in the field-of-view. On both occasions the patient had to pay for the scan. On the 2004 PET-CT scan, the CT brain revealed multiple hyperdense lesions consistent with hemorrhagic metastases. In addition, there were innumerable glucose avid foci involving viscera, nodes and skeleton consistent with disseminated disease. Our case illustrates: (i) the value of PET in the management of metastatic breast cancer; (ii) the improved accuracy of PET-CT in delineating sites of disease; (iii) the issues of head movement in PET-CT and. (iv) the problem with lack of

  14. CT evaluation of hepatocellular carcinomas supplied by right inferior phrenic arteries

    International Nuclear Information System (INIS)

    Wen Ming; Zhu Mingxia; Huang Yonghuo

    2002-01-01

    Objective: To evaluate the CT appearance of the hepatocellular carcinomas (HCC) supplied by the right inferior phrenic arteries (RIPA). Methods: A total of 195 consecutive cases of HCCs examined with helical CT and arteriography were studied. 15 proven HCCs cases were supplied by the RIPA. On arterial-phase CT images, the size of the RIPA, the left inferior phrenic arteries, and HCCs were measured, and the origin of RIPA and the location of HCCs were recorded. The CT findings in these 15 cases were correlated with arterio-graphic images. Results: CT showed RIPA on the right diaphragmatic crus as high attenuation in all patients. The origin of RIPA was demonstrated in 11 cases. The diameter of the RIPA (3.1 +- 1.1) mm was larger than that of the left inferior phrenic artery (1.3 +- 0.4) mm (P < 0.05). Conclusion: On CT images, if the RIPA asymmetrically dilates, and its diameter is larger than 2.5 mm, it is suggested that the HCC is supplied by the RIPA

  15. Idiopathic pulmonary fibrosis with coexisting emphysema : high-resolution CT and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Young; Kim, Kyeong Ah; Oh, Yu Whan; Shim, Jae Jeong; Kang, Kyung Ho [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-05-01

    To correlate high-resolution CT (HRCT) findings with smoking history and pulmonary function test (PFT) in patients with idiopathic pulmonary fibrosis (IPF) with or without coexisting emphsema. The study included 24 patients who had undergone HRCT and in whom IPF had been confirmed pathologically (n=7) and clinically (n=17). The patients included 19 men and 5 women aged between from 44 and 78(mean 59) years. HRCT findings were reviewed by two radiologists and assessed for the presence and extent of emphysema (CT emphysema score;CES) and honeycombing (CT honeycombing score;CHS). CES and CHS were retrospectively correlated with smoking status and pulmonary function test. Evidence of emphysema was seen on HRCT in 20 fo 24 patients with IPF (83%). CES was 14.3 and CHS was 18.1 in smokers with IPF, as compared with 1.8 and 6.7 in nonsmokers (p<0.01). Pulmonary function tests showed lower percent predicted FEVI (69.3%), FVC (64.7%), TLC (73.7%), and RV (77.3%), a lower percent predicted diffusing capacity of carbon monoxide (58.2%), and normal FEVI/FVC (99.1%). The pulmonary function test in smokers showed higher TLC and RV than in nonsmokers. Eight of nine patients whose CES was higher than their CHS, an seen on HRCT, were smokers and had a smoking history of 33.1 pack-years. Seven of 15 whose CHS was higher than their CES were smokers and had a smoking history of 16.8 pack-years. In patients with a higher CES than CHS pulmonary function test results showed normal TLC(85%) and RV(100.7%); this contrasted with decreased TLC(72%) and RV (68%) in patients whose CHS was higher than their CES. Emphysema is a frequently associated finding in patients with IPF, as seen on HRCT, and emphysema is more frequent and extensive in smokers with IPF than non-smokers. HRCT is useful for detecting emphysema in patients with IPF, and the extent of emphysema on HRCT correlates with the results of the pulmonary function test and smoking status.

  16. Idiopathic pulmonary fibrosis with coexisting emphysema : high-resolution CT and clinical correlation

    International Nuclear Information System (INIS)

    Kang, Eun Young; Kim, Kyeong Ah; Oh, Yu Whan; Shim, Jae Jeong; Kang, Kyung Ho

    1997-01-01

    To correlate high-resolution CT (HRCT) findings with smoking history and pulmonary function test (PFT) in patients with idiopathic pulmonary fibrosis (IPF) with or without coexisting emphsema. The study included 24 patients who had undergone HRCT and in whom IPF had been confirmed pathologically (n=7) and clinically (n=17). The patients included 19 men and 5 women aged between from 44 and 78(mean 59) years. HRCT findings were reviewed by two radiologists and assessed for the presence and extent of emphysema (CT emphysema score;CES) and honeycombing (CT honeycombing score;CHS). CES and CHS were retrospectively correlated with smoking status and pulmonary function test. Evidence of emphysema was seen on HRCT in 20 fo 24 patients with IPF (83%). CES was 14.3 and CHS was 18.1 in smokers with IPF, as compared with 1.8 and 6.7 in nonsmokers (p<0.01). Pulmonary function tests showed lower percent predicted FEVI (69.3%), FVC (64.7%), TLC (73.7%), and RV (77.3%), a lower percent predicted diffusing capacity of carbon monoxide (58.2%), and normal FEVI/FVC (99.1%). The pulmonary function test in smokers showed higher TLC and RV than in nonsmokers. Eight of nine patients whose CES was higher than their CHS, an seen on HRCT, were smokers and had a smoking history of 33.1 pack-years. Seven of 15 whose CHS was higher than their CES were smokers and had a smoking history of 16.8 pack-years. In patients with a higher CES than CHS pulmonary function test results showed normal TLC(85%) and RV(100.7%); this contrasted with decreased TLC(72%) and RV (68%) in patients whose CHS was higher than their CES. Emphysema is a frequently associated finding in patients with IPF, as seen on HRCT, and emphysema is more frequent and extensive in smokers with IPF than non-smokers. HRCT is useful for detecting emphysema in patients with IPF, and the extent of emphysema on HRCT correlates with the results of the pulmonary function test and smoking status

  17. CT versus FDG-PET/CT response evaluation in patients with metastatic colorectal cancer treated with irinotecan and cetuximab

    DEFF Research Database (Denmark)

    Skougaard, Kristin; Johannesen, Helle Hjorth; Nielsen, Dorte

    2014-01-01

    included in a phase II trial and treated with cetuximab and irinotecan every second week. They underwent FDG-PET/CT examination at baseline and after every fourth treatment cycle. Response evaluation was performed prospectively according to Response Evaluation Criteria in Solid Tumors (RECIST 1...

  18. Synchrotron X-ray CT of rose peduncles. Evaluation of tissue damage by radiation

    International Nuclear Information System (INIS)

    Herppich, Werner B.; Zabler, Simon; Dawson, Martin; Choinka, Gerard; Manke, Ingo

    2015-01-01

    ''Bent-neck'' syndrome, an important postharvest problem of cut roses, is probably caused by water supply limitations and/or the structural weakness of vascular bundles of the peduncle tissue. For this reason, advanced knowledge about the microstructures of rose peduncles and their cultivar specific variations may lead to a better understanding of the underlying mechanisms. Synchrotron X-ray computed tomography (SXCT), especially phase-based CT, is a highly suitable technique to nondestructively investigate plants' micro anatomy. SXCT with monochromatic X-ray beams of 30, 40 and 50 keV photon energy was used to evaluate the three-dimensional inner structures of the peduncles of 3 rose cultivars that differ greatly in their bent-neck susceptibility. Results indicated that this technique achieves sufficiently high spatial resolution to investigate complex tissues. However, further investigations with chlorophyll fluorescence analysis (CFA) and optical microscope imagery reveal different kinds of heavy damage of the irradiated regions induced by synchrotron X-rays; in a cultivar-specific manner, partial destruction of cell walls occurred a few hours after X-ray irradiation. Furthermore, a delayed inhibition of photosynthesis accompanied by the degradation of chlorophyll was obvious from CFA within hours and days after the end of CT measurements. Although SXCT is certainly well suited for three-dimensional anatomical analysis of rose peduncles, the applied technique is not nondestructive.

  19. Synchrotron X-ray CT of rose peduncles. Evaluation of tissue damage by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Herppich, Werner B. [Leibniz-Institut fuer Agrartechnik Potsdam-Bornim e.V., Potsdam (Germany). Abt. Technik im Gartenbau; Matsushima, Uzuki [Iwate Univ., Morioka (Japan). Faculty of Agriculture; Graf, Wolfgang [Association for Technology and Structures in Agriculture (KTBL), Darmstadt (Germany); Zabler, Simon [Fraunhofer-Institut fuer Integrierte Schaltungen (IIS), Wuerzburg (Germany). Project group NanoCT Systems (NCTS); Dawson, Martin [Salford Univ., Greater Manchester (United Kingdom); Choinka, Gerard; Manke, Ingo [Helmholtz Center Berlin for Materials and Energy (HZB), Berlin (Germany)

    2015-02-01

    ''Bent-neck'' syndrome, an important postharvest problem of cut roses, is probably caused by water supply limitations and/or the structural weakness of vascular bundles of the peduncle tissue. For this reason, advanced knowledge about the microstructures of rose peduncles and their cultivar specific variations may lead to a better understanding of the underlying mechanisms. Synchrotron X-ray computed tomography (SXCT), especially phase-based CT, is a highly suitable technique to nondestructively investigate plants' micro anatomy. SXCT with monochromatic X-ray beams of 30, 40 and 50 keV photon energy was used to evaluate the three-dimensional inner structures of the peduncles of 3 rose cultivars that differ greatly in their bent-neck susceptibility. Results indicated that this technique achieves sufficiently high spatial resolution to investigate complex tissues. However, further investigations with chlorophyll fluorescence analysis (CFA) and optical microscope imagery reveal different kinds of heavy damage of the irradiated regions induced by synchrotron X-rays; in a cultivar-specific manner, partial destruction of cell walls occurred a few hours after X-ray irradiation. Furthermore, a delayed inhibition of photosynthesis accompanied by the degradation of chlorophyll was obvious from CFA within hours and days after the end of CT measurements. Although SXCT is certainly well suited for three-dimensional anatomical analysis of rose peduncles, the applied technique is not nondestructive.

  20. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  1. Cardiac CT and cardiac MRI - competitive or complementary for nuclear cardiology

    International Nuclear Information System (INIS)

    Moshage, W.

    2004-01-01

    In summary, cardiac computed tomography (CT) and cardiac magnetic resonance (MR) are two different technologies with distinct imaging properties that gain increasing importance in clinical cardiology. Even though images may look similar, the areas of application of CT and MR are quite different. Clinical applications of cardiac CT focus on on-invasive imaging of the coronary arteries. In this respect, the higher spatial resolution of cardiac CT constitutes a significant advantage as compared to MR and clinical results are superior. Clinical applications of cardiac MR, next to morphologic imaging of the heart, are most frequently found in the context of intra-and pericardial masses, complex congenital anomalies, and the assessment of left ventricular function (dobutamine) and perfusion (adenosine) under stress. The evaluation of the size and localization of myocardial necrosis, scars, and fibrosis gains increasing importance, for example in the workup of myocardial infarction, but also myocarditis and cardiomyopathies. In this respect, magnetic resonance imaging partly constitutes an alternative to nuclear medicine methods. Due to the lack of ionizing radiation and a relatively high spatial resolution, an increase of MR diagnostic procedures at the expense of nuclear medicine can be expected. (orig.)

  2. Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction

    Science.gov (United States)

    Niu, Shanzhou; Yu, Gaohang; Ma, Jianhua; Wang, Jing

    2018-02-01

    Spectral computed tomography (CT) has been a promising technique in research and clinics because of its ability to produce improved energy resolution images with narrow energy bins. However, the narrow energy bin image is often affected by serious quantum noise because of the limited number of photons used in the corresponding energy bin. To address this problem, we present an iterative reconstruction method for spectral CT using nonlocal low-rank and sparse matrix decomposition (NLSMD), which exploits the self-similarity of patches that are collected in multi-energy images. Specifically, each set of patches can be decomposed into a low-rank component and a sparse component, and the low-rank component represents the stationary background over different energy bins, while the sparse component represents the rest of the different spectral features in individual energy bins. Subsequently, an effective alternating optimization algorithm was developed to minimize the associated objective function. To validate and evaluate the NLSMD method, qualitative and quantitative studies were conducted by using simulated and real spectral CT data. Experimental results show that the NLSMD method improves spectral CT images in terms of noise reduction, artifact suppression and resolution preservation.

  3. Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma.

    Science.gov (United States)

    Nakajima, Reiko; Abe, Koichiro; Kondo, Tsunenori; Tanabe, Kazunari; Sakai, Shuji

    2016-06-01

    We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB phases, and compared the accumulation values with regard to histological type (clear cell carcinoma [CCC] vs. non-clear cell carcinoma [N-CCC]), the TNM stage (high stage [3-4] vs. low stage [1-2]), the Fuhrman grade (high grade [3-4] vs. low grade [1-2]) and presence versus absence of venous (V) and lymphatic (Ly) invasion. In the ED phase, visual evaluation revealed no significant differences in FDG accumulation in terms of each item. However, the maximum standardized uptake value and tumour-to-normal tissue ratios were significantly higher in the CCCs compared to the N-CCCs (p PET/CT is a useful tool for the evaluation of RCCs. • ED and WB FDG-PET/ CT helps to assess patients with RCC • ED FDG-PET/CT enabled differentiation between CCC and N-CCC • FDG accumulation in the WB phase reflects tumour aggressiveness • Management of RCC is improved by ED and WB FDG-PET/CT.

  4. Iodine and freeze-drying enhanced high-resolution MicroCT imaging for reconstructing 3D intraneural topography of human peripheral nerve fascicles.

    Science.gov (United States)

    Yan, Liwei; Guo, Yongze; Qi, Jian; Zhu, Qingtang; Gu, Liqiang; Zheng, Canbin; Lin, Tao; Lu, Yutong; Zeng, Zitao; Yu, Sha; Zhu, Shuang; Zhou, Xiang; Zhang, Xi; Du, Yunfei; Yao, Zhi; Lu, Yao; Liu, Xiaolin

    2017-08-01

    The precise annotation and accurate identification of the topography of fascicles to the end organs are prerequisites for studying human peripheral nerves. In this study, we present a feasible imaging method that acquires 3D high-resolution (HR) topography of peripheral nerve fascicles using an iodine and freeze-drying (IFD) micro-computed tomography (microCT) method to greatly increase the contrast of fascicle images. The enhanced microCT imaging method can facilitate the reconstruction of high-contrast HR fascicle images, fascicle segmentation and extraction, feature analysis, and the tracing of fascicle topography to end organs, which define fascicle functions. The complex intraneural aggregation and distribution of fascicles is typically assessed using histological techniques or MR imaging to acquire coarse axial three-dimensional (3D) maps. However, the disadvantages of histological techniques (static, axial manual registration, and data instability) and MR imaging (low-resolution) limit these applications in reconstructing the topography of nerve fascicles. Thus, enhanced microCT is a new technique for acquiring 3D intraneural topography of the human peripheral nerve fascicles both to improve our understanding of neurobiological principles and to guide accurate repair in the clinic. Additionally, 3D microstructure data can be used as a biofabrication model, which in turn can be used to fabricate scaffolds to repair long nerve gaps. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  6. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon

    1988-01-01

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult cases.

  7. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  8. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  9. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  10. RADIOLOGICAL EVALUATION OF OBSTRUCTIVE JAUNDICE BY ULTRASOUND AND CT

    Directory of Open Access Journals (Sweden)

    Padmalatha

    2015-10-01

    Full Text Available INTRODUCTION: The goals of any radiologic procedure in obstructive Jaundice are to confirm the presence of bile duct obstruction, its location, its extent & the probable cause. It should also attempt to obtain a map of the biliary tree that will help the surgeon to det ermine the best approach to each individual case. OBJECTIVES: 1. To evaluate the role of Ultrasound and CT in patients presenting with clinical features of obstructive jaundice. 2. To evaluate the causes of obstructive jaundice by Ultrasound and CT. PATIENTS AND METHODS: The study was carried with 45 patients from January 2006 to September 2007 who were attending the surgical and Gastroenterology Departments, Govt. General Hospital, Kurnool, which is an attached hospital to Kurnool Medical College, Kurnool. O BSERVATIONS AND RESULTS: In our study, there is female predominance with male: female ratio 1: 1.6.Majority of patients are in age group of 41 - 50 years. Jaundice was the commonest presentation in all patients followed by pruritis in 72% and pain abdomen in 67% of patients. Ultrasound identified the benign cause of biliary obstruction in 79.1% cases and the malignant cause in 61.9% cases. CT identified the benign cause of biliary obstruction in 91.6% of patients and the malignant cause in 80.9% cases.

  11. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  12. How safe is teleradiological telediagnosis for CT imaging?

    International Nuclear Information System (INIS)

    Ricke, J.; Wolf, M.; Hosten, N.; Zielinski, C.; Liebig, T.; Lopez-Haenninen, E.; Lemke, A.J.; Siekmann, R.; Stroszczynski, C.; Schauer, W.; Amthauer, H.; Kleinholz, L.; Felix, R.

    1997-01-01

    Purpose: To define the value of teleradiographic studies, a comparison was carried out between digitised copies of CT examinations of the skull with the original images. Differences in image quality obtained from a digital scanner and a camera were quantified. Material and method: 56 CT examinations of the skull, 28 of which had discrete abnormalities, were chosen for ROC analysis. The original films were digitised with a Vidar VXR-12 scanner and Panasonic WV-160 and WV-PB 500 cameras. The images were evaluated by five radiologists after image transfer with Video Conference software to a personal computer. Results: For the analysis of the films the area under the ROC curve was 0.91±0.04, for the digital scanner it was 0.85±0.04, for camera WV-BP 500 0.89±0.06 and for camera WE-160 0.87±0.09. Comprison with the film findings showed a minimal p-value of 0.17 which indicated that there was no significant reduction in diagnostic value following digitisation. Conclusion: The probable reason for the slight deterioration using the digital scanner was the reduction to 75 dpi compared with 134 dpi on the CT films. The cameras produce image noise comparable to CT with low window settings and reduced local resolution. We expect similar results for CT with soft tissue windows or for MRT of the skull. Conventional radiographs containing high local resolution, wide grey scale and low image noise would presumably make higher demands on methods of digitisation. (orig.) [de

  13. How to perform dosimetry with Optical CT

    International Nuclear Information System (INIS)

    Wuu, Cheng-Shie; Xu, Y

    2010-01-01

    Both polymer gels and PRESAGE radiochromic solid dosimeter, in conjunction with optical CT scanning system, have been employed to measure 3-D dose distribution. The 3-D dose maps obtained from these systems can provide a useful tool for dose verification on complex treatments such as IMRT, radiosurgery, and RapidArc. These complex treatments present high dose gradient regions in the boundaries between the target and the surrounding critical organs. Dose accuracy in these areas can be critical, and may affect the treatment. There is a pressing need for a dosimeter that allows for accurate determination of 3-D dose distribution with high spatial resolution. In this paper, performance of polymer gels and PRESAGE dosimeter with optical CT scanning is reviewed and evaluated in terms of their sensitivity calibration, irradiation, optimization of scanning procedures, precision, and accuracy. Clinical applications of optical-CT dosimetry are presented.

  14. Imaging of bronchiectasis: the great value of high-resolution CT in differential diagnosis; Differenzialdiagnose der Bronchiektasen: High-resolution CT als wertvolle Hilfe

    Energy Technology Data Exchange (ETDEWEB)

    Heckmann, M.; Kramann, B.; Heinrich, M. [Klinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany); Uder, M. [Inst. fuer Diagnostische Radiologie, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany)

    2006-07-01

    Bronchiectasis is defined as localized irreversible dilatation of the bronchial tree. Brochiectasis has been associated with a wide variety of causes, but it is mostly caused by acute, chronic or recurrent infections. This paper should give a review about the manifestation of bronchiectasis and bronchioloectasis in HR-CT and discuss the causing entities. However, integration of bronchiectasis and other HR-CT findings may enable a narrower differential diagnosis, in some cases it is possible to give the correct diagnose directly. (orig.)

  15. Clinical applications of the imatron fast CT scanner

    International Nuclear Information System (INIS)

    Stanford, W.

    1986-01-01

    Utilizing three imaging modes, Cine CT has proven satisfactory in the assessment of left ventricular mass and function including ejection fractions and abnormalities of wall motion. It is helpful in documenting pericardial constrictions, as well as in assessing intracavitary tumors and thrombi. In the lungs, it is used to document AV fistulae and to evaluate the vascularity of mediastinal masses and to exclude invasion or major thoracic vessels. It can be used, as in the conventional scanner, for needle directed lung and chest well biopsies. It is frequently used in a airway studies to differentiate fixed from physiologic constrictions and to assess tracheomalacia and bronchopulmonary dysplasias. It can be used to plan radiation ports in the treatment of breast carcinoma. In the abdomen, successful applications include its use in the assessment of renal blood flow and the evaluation of cavernous hemangiomas of the liver as well as in screening of possible aortic aneurysms. In orthopedics, Cine CT is used to evaluate patellofermoral tracking in subluxations of the patella and used to evaluate subluxations and dislocations of the radio-ulnar joint. Cine CT by virtue of its speed and satisfactory spatial resolution is a significant imaging modality for evaluating the beating heart. Other applications include the evaluation of aortic aneurysms and dissections, para-aortic mass lesions, airway obstructions and patellar tracking and forearm subluxations

  16. PET/CT and vascular disease: Current concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Souza Leao Lima, Ronaldo de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Souza Machado Neto, Luiz de [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Kayat Bittencourt, Leonardo, E-mail: lkayat@terra.com.br [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil); Cortes Domingues, Romeu [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Fonseca, Lea Mirian Barbosa da [CDPI and Multi-Imagem Clinics, Rio de Janeiro (Brazil); Department of Radiology, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro (Brazil)

    2011-10-15

    Since its introduction in 2001, positron emission tomography associated to computed tomography (PET/CT) has been established as a standard tool in cancer evaluation. Being a multimodality imaging method, it combines in a single session the sensitivity granted by PET for detection of molecular targets within the picomolar range, with an underlying submilimetric resolution inherent to CT, that can precisely localize the PET findings. In this last decade, there have been new insights regarding the pathophysiology of atherosclerosis, particularly about plaque rupture and vascular remodeling. This has increased the interest for research on PET/CT in vascular diseases as a potential new diagnostic tool, since some PET molecular targets could identify diseases before the manifestation of gross anatomic features. In this review, we will describe the current applications of PET/CT in vascular diseases, emphasizing its usefulness in the settings of vasculitis, aneurysms, vascular graft infection, aortic dissection, and atherosclerosis/plaque vulnerability. Although not being properly peripheral vascular conditions, ischemic cardiovascular disease and cerebrovascular disease will be briefly addressed as well, due to their widespread prevalence and importance.

  17. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  18. MR imaging versus PET/CT for evaluation of pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Belião, Sara, E-mail: sara.beliao@clix.pt [Department of Radiology Hospital S. Francisco Xavier, Estrada do Forte do Alto do Duque, 1495-005 Lisbon (Portugal); Ferreira, Alexandra, E-mail: alexandratavaresferreira@gmail.com [Department of Radiology, Hospital D. Estefânia, Rua Jacinta Marto, 1169-045 Lisbon (Portugal); Vierasu, Irina, E-mail: Ortansa-Irina.Vierasu@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Blocklet, Didier, E-mail: dblockle@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Goldman, Serge, E-mail: petscan@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Metens, Thierry, E-mail: tmetens@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium); Matos, Celso, E-mail: cmatos@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium)

    2012-10-15

    Purpose: To retrospectively determine the diagnostic accuracy of magnetic resonance imaging (MRI) and combined positron emission tomography/computed tomography (PET/CT) in the differential diagnosis of benign and malignant pancreatic lesions. Materials and methods: Twenty-seven patients (15 women/12 men, mean age 56.5 years) with MR imaging and PET/CT studies performed to differentiate benign and malignant pancreatic lesions were identified between October 2008 and October 2010. Both MR and PET/CT data sets were retrospectively and blindly evaluated by two independent readers (4 readers total) with different degrees of experience, using a visual five-point score system. The results were correlated with final diagnosis obtained by histopathology. Results: 17 patients had malignant diseases and 10 patients had benign diseases. Depending on the observer, the sensitivity, specificity, positive predictive value and negative predictive value of MRI varied between 88–94%, 50–80%, 75–89% and 71–89% respectively. Sensitivities, specificities, positive predictive values and negative predictive values of PET/CT were 73%, 56%, 73% and 56% respectively. The diagnostic accuracy of MR for the differential diagnosis of pancreatic lesions was 74–89%, compared with 67% for PET/CT. The weighted Cohen's kappa coefficient was 0.47 at MR and 0.53 at PET/CT. Conclusion: MRI achieved higher sensitivity and specificity in the differential diagnosis of pancreatic lesions.

  19. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  20. Visualization of Tooth for Non-Destructive Evaluation from CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hui; Chae, Ok Sam [Kyung Hee University, Seoul (Korea, Republic of)

    2009-06-15

    This paper reports an effort to develop 3D tooth visualization system from CT sequence images as a part of the non-destructive evaluation suitable for the simulation of endodontics, orthodontics and other dental treatments. We focus on the segmentation and visualization for the individual tooth. In dental CT images teeth are touching the adjacent teeth or surrounded by the alveolar bones with similar intensity. We propose an improved level set method with shape prior to separate a tooth from other teeth as well as the alveolar bones. Reconstructed 3D model of individual tooth based on the segmentation results indicates that our technique is a very conducive tool for tooth visualization, evaluation and diagnosis. Some comparative visualization results validate the non-destructive function of our method.

  1. Prospective evaluation of MRI, 11C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    International Nuclear Information System (INIS)

    Vargas, H.A.; Akin, O.; Schöder, H.; Olgac, S.; Dalbagni, G.; Hricak, H.; Bochner, B.H.

    2012-01-01

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11 C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11 C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11 C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, 11 C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  2. Evaluation of registration methods on thoracic CT

    DEFF Research Database (Denmark)

    Murphy, K.; van Ginneken, B.; Reinhardt, J.

    2011-01-01

    method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing......EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra-patient thoracic CT image pairs. Evaluation of non-rigid registration techniques is a non trivial task....... This article details the organisation of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed....

  3. Normal CT anatomy of the spine

    International Nuclear Information System (INIS)

    Quiroga, O.; Matozzi, F.; Beranger, M.; Nazarian, S.; Salamon, G.; Gambarelli, J.

    1982-01-01

    To analyse the anatomo-radiological correlation of the spine and spinal cord, 22 formalized, frozen anatomical specimens corresponding to different regions of the spinal column (8 cervical, 5 dorsal, and 9 lumbar) were studied by CT scans on axial, sagittal and coronal planes and by contact radiography after they were cut into anatomical slices in order to clarify the normal CT anatomy of the spinal column. The results obtained from CT patient scans, performed exclusively on the axial plane, were compared with those obtained from the anatomical specimens (both CT and contrast radiography). High resolution CT programs were used, enabling us to obtain better individualization of the normal structures contained in the spinal column. Direct sagittal and coronal sections were performed on the specimens in order to get further anatomo-radiological information. Enhanced CT studies of the specimens were also available because of the air already present in the subarachnoid spaces. Excellent visualization was obtained of bone structures, soft tissue and the spinal cord. High CT resolution of the spine appeares to be an excellent neuroradiological procedure to study the spine and spinal cord. A metrizamide CT scan is, however, necessary when a normal unenhanced CT scan is insufficient for diagnosis and when the spinal cord is not clearly visible, as often happens at the cervical level. Clinical findings are certainly very useful to ascertain the exact CT level and to limit the radiation exposure. (orig.)

  4. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  5. An assessment of the dose received by children from CT examinations along with the quality control parameters from a conventional CT system

    International Nuclear Information System (INIS)

    Sadeghyani, T.; Hashemi Malayeri, B.; Hashemi, H.; Sharafi, A. A.

    2005-01-01

    In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. Children are more sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be carried out periodically on the CT scanners. The aim of this research was to estimate the effective doses received by the children below two years of age from routine CT examinations carried out at an educational imaging center in Tehran. It was also aimed to evaluate the quality control parameters of the mentioned CT scanner at the same time. Materials and Methods: In this study, the Computed Tomography Dose Index were measured at the central axis of the CT gantry in air and in the standard quality control phantoms of the head and body (as recommended by the FDA) using a pencil ionization chamber and LiF TLD pellets for a single scan. By using the measured Computed Tomography Dose Index values and the IrnPACT software, the effective doses were calculated for every routine CT examination protocol. In this study, the quality control parameters such as noise, CT number calibration, high and low contrast resolution and the flatness of the CT image were also evaluated. These parameters were also measured using standard procedures and test objects. Results: The effective dose estimated in this research ranged from 2.05 to 21.45 and 2.05 to 15.7 mSv for the female and male children, respectively. The measured values of the Computed Tomography Dose Index in the standard head and body phantoms were 20.6) 2.01 and 11.13 f 1.04 mGy1100 mAs, respectively. The high and low contrast resolution was estimated to be 0.8 mm and 1.0 rnm, respectively. Conclusion: The estimated values of the effective doses in this research were less than the values reported for the Netherlands, the USA, Germany and were comparable with the values reported in the UK. The measured Computed Tomography Dose Index values were 11

  6. Scout-view assisted interior micro-CT

    International Nuclear Information System (INIS)

    Sharma, Kriti Sen; Narayanan, Shree; Agah, Masoud; Holzner, Christian; Vasilescu, Dragoş M; Jin, Xin; Hoffman, Eric A; Yu, Hengyong; Wang, Ge

    2013-01-01

    Micro computed tomography (micro-CT) is a widely-used imaging technique. A challenge of micro-CT is to quantitatively reconstruct a sample larger than the field-of-view (FOV) of the detector. This scenario is characterized by truncated projections and associated image artifacts. However, for such truncated scans, a low resolution scout scan with an increased FOV is frequently acquired so as to position the sample properly. This study shows that the otherwise discarded scout scans can provide sufficient additional information to uniquely and stably reconstruct the interior region of interest. Two interior reconstruction methods are designed to utilize the multi-resolution data without significant computational overhead. While most previous studies used numerically truncated global projections as interior data, this study uses truly hybrid scans where global and interior scans were carried out at different resolutions. Additionally, owing to the lack of standard interior micro-CT phantoms, we designed and fabricated novel interior micro-CT phantoms for this study to provide means of validation for our algorithms. Finally, two characteristic samples from separate studies were scanned to show the effect of our reconstructions. The presented methods show significant improvements over existing reconstruction algorithms. (paper)

  7. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization

    International Nuclear Information System (INIS)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A.; Nunziata, A.

    2000-01-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyperattenuation in the arterial phase and hypo-isoattenuation in the portal and/or delayed phase, or with hypo-isoattenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hypervascular and 1 hypovascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemoembolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this technique has

  8. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  9. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  10. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  11. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  12. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    Energy Technology Data Exchange (ETDEWEB)

    Demirkazik, Figen Basaran E-mail: demirkaz@dialup.ankara.edu.tr; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P<0.0001) and clinical points (r=0.67, P<0.0001) of the Shwachman-Kulczycki system, FVC (r=0.71 P=0.004) and FEV{sub 1} (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV{sub 1} (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry.

  13. Evaluation of the robustness of the preprocessing technique improving reversible compressibility of CT images: Tested on various CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Chang Ho; Kim, Bohyoung; Gu, Bon Seung; Lee, Jong Min [Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Kim, Kil Joong [Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707, South Korea and Department of Radiation Applied Life Science, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul 110-799 (Korea, Republic of); Lee, Kyoung Ho [Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707, South Korea and Institute of Radiation Medicine, Seoul National University Medical Research Center, and Clinical Research Institute, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744 (Korea, Republic of); Kim, Tae Ki [Medical Information Center, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of)

    2013-10-15

    Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique was developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.

  14. Brain perfusion-CT in acute stroke patients

    International Nuclear Information System (INIS)

    Andreev, T.; Totsev, N.; Tzvetanov, P.

    2013-01-01

    Since 1979 when Grodfrey Hounsfield and Allan Corman introduced the computed tomography new generations of CT were developed that improved the special resolution and time of acquisition. The role of neuro-imaging in the evaluation of acute stroke has changed dramatically in the past decade. Previously, neuro-imaging was used in this set-ting to provide anatomic imaging that indicated the presence or absence of acute cerebral ischemia and excluded lesions that produce symptoms or signs mimicking those of stroke, such as hemorrhage and neoplasms. More recently, the introduction of thrombolysis has changed the goals of neuro-imaging from providing solely anatomic information to providing physiologic information that could help to determine which patients might benefit from therapy. In particular, significant emphasis has been placed on the delineation of the ischemic penumbra, also called tissue at risk. Modem CT survey, consisting of three indissociable elements; noncontrast CT (NCT) of course, perfusion-CT (PCT) and CT-angiography (CTA), fulfill all the requirements for hyperacute stroke imaging. CTA can define the occlusion site, depict arterial dissection, grade collateral blood flow, and characterize atherosclerotic disease, whereas PCT accurately defines the infarct core and the ischemic penumbra. CT offers a number of practical advantages over other cerebral perfusion imaging methods, including its wide availability. Using PCT and CTA to define new individualized strategies for acute reperfusion will allow more acute stroke patients to benefit from thrombolytic therapy. Key words: Stroke. Penumbra. Computed Tomography. Perfusion-CT. CT Angiography. Outcome

  15. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  16. Early smoking-induced lung lesions in asymptomatic subjects. Correlations between high resolution dynamic CT and pulmonary function testing

    International Nuclear Information System (INIS)

    Spaggiari, Enrica; Zompadori, Maurizio; Bna', Claudio; Ormitti, Francesca; Svaerzellati, Nicola; Rabaiotti, Enrico; Verduri, Alessia; Chetta, Alfredo

    2005-01-01

    Purpose: To evaluate the prevalence and significance of the pathological effects of cigarette smoking on the lung and the sensitivity of high-resolution CT (HRCT) in the recognition of early smoking-induced lesions in asymptomatic former of current smokers. Materials and methods: We performed a prospective and consecutive analysis of 36 volunteers (16 males, 20 females), 10 non-smokers (3 males, 7 females) and 26 smokers (13 males, 13 females / 17 current smokers; 9 former smokers), all asymptomatic and with normal respiratory flows. These subjects underwent lung function testing and HRCT, after providing written informed consent for the study. The HRCT scans were obtained at three pre-selected levels (aortic arch, tracheal carina and venous hilum). The same scans were obtained in post-expiration phase. At the level of the apical segmental bronchus of the right upper lobe, we measured on the monitor wall thickening, and the total and internal diameters using the techniques reported in literature. Each study was independently evaluated by two radiologists that were blinded to all clinical and functional data: they also evaluated the presence, prevalence and type of emphysema, areas of patchy hyperlucency and oligoemia in the inspiration phase and areas of expiratory air trapping. The extension was evaluated with the visual score method. The data obtained were analysed with the Windows SPSS package for statistical analysis. Results: The two groups (non smokers and smokers) showed significant differences in some functional tests such as FEV1 (p [it

  17. CT in the evaluation of space-occupying lesions of the thoracic and abdominal wall

    International Nuclear Information System (INIS)

    Marchal, G.; Coenen, Y.; Baert, A.L.; Wilms, G.

    1979-01-01

    The progress of CT is predominantly based upon a higher densitometric resolution. Besides the bony skeleton, still more precisely studied by conventional techniques, the different soft components of the wall can now be directly and distinctly visualized. It is our experience that CT represents an important contribution in the diagnosis of wall lesions for the following reasons: 1. Correct topographic delineation of space-occupying masses, even when these cannot be visualized by conventional X-ray examination. 2. Indication of extension, with all the practical surgical and radiotherapeutic consequences. 3. It is a very valuable noninvasive method of follow-up of these soft tissue masses in radiotherapy as well as in chemotherapy. (orig.) 891 MG/orig. 892 MB [de

  18. Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system

    International Nuclear Information System (INIS)

    Court, Laurence; Rosen, Isaac; Mohan, Radhe; Dong Lei

    2003-01-01

    A new integrated CT/LINAC combination, in which the CT scanner is inside the radiation therapy treatment room and the same patient couch is used for CT scanning and treatment (after a 180-degree couch rotation), should allow for accurate correction of interfractional setup errors. The purpose of this study was to evaluate the sources of uncertainties, and to measure the overall precision of this system. The following sources of uncertainty were identified: (1) the patient couch position on the LINAC side after a rotation, (2) the patient couch position on the CT side after a rotation, (3) the patient couch position as indicated by its digital readout, (4) the difference in couch sag between the CT and LINAC positions, (5) the precision of the CT coordinates, (6) the identification of fiducial markers from CT images, (7) the alignment of contours with structures in the CT images, and (8) the alignment with setup lasers. The largest single uncertainties (one standard deviation or 1 SD) were found in couch position on the CT side after a rotation (0.5 mm in the RL direction) and the alignment of contours with the CT images (0.4 mm in the SI direction). All other sources of uncertainty are less than 0.3 mm (1 SD). The overall precision of two setup protocols was investigated in a controlled phantom study. A protocol that relies heavily on the mechanical integrity of the system, and assumes a fixed relationship between the LINAC isocenter and the CT images, gave a predicted precision (1 SD) of 0.6, 0.7, and 0.6 mm in the SI, RL and AP directions, respectively. The second protocol reduces reliance on the mechanical precision of the total system, particularly the patient couch, by using radio-opaque fiducial markers to transfer the isocenter information from the LINAC side to the CT images. This protocol gave a slightly improved predicted precision of 0.5, 0.4, and 0.4 mm in the SI, RL and AP directions, respectively. The distribution of phantom position after CT

  19. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  20. Study of CT-based positron range correction in high resolution 3D PET imaging

    International Nuclear Information System (INIS)

    Cal-Gonzalez, J.; Herraiz, J.L.; Espana, S.; Vicente, E.; Herranz, E.; Desco, M.; Vaquero, J.J.; Udias, J.M.

    2011-01-01

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  1. SU-F-I-55: Performance Evaluation of Digital PET/CT: Medical Physics Basis for the Clinical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J; Knopp, MV [The Ohio State University, Columbus, OH (United States); Miller, M [Philips Healthcare, Highland Heights, OH (United States)

    2016-06-15

    Purpose: Replacement of conventional PMT-based detector with next generation digital photon counting (DPC) detector is a technology leap for PET imaging. This study evaluated the performance and characteristics of the DPC system and its stability within a 1 year time window following its installation focusing on the medical physics basis for clinical applications. Methods: A digital PET/CT scanner using 1:1 coupling of 23,040 crystal: detector elements was introduced and became operational at OSU. We tested and evaluated system performance and characteristics using NEMA NU2-2012. System stabilities in timing resolution, energy resolution, detector temperature and humidity (T&H) were monitored over 1-yr. Timing, energy and spatial resolution were characterized across clinically relevant count rate range. CQIE uniformity PET and NEMA IEC-Body PET with hot spheres varying with sizes and contrasts were performed. PET reconstructed in standard(4mm), High(2mm) and Ultra-High(1mm) definitions were evaluated. Results: NEMA results showed PET spatial resolution (mm-FWHM) from 4.01&4.14 at 1cm to 5.82&6.17 at 20cm in transverse & axial. 322±3ps timing and 11.0% energy resolution were measured. 5.7kcps/MBq system sensitivity with 24kcps/MBq effective sensitivity was obtained. The peak-NECR was ∼171kcps with the effective peak-NECR >650kcps@50kBq/mL. Scatter fraction was ∼30%, and the maximum trues was >900kcps. NEMA IQ demonstrated hot sphere contrast ranging from ∼62%±2%(10mm) to ∼88%±2%(22mm), cold sphere contrast of ∼86%±2%(28mm) and ∼89%±3%(37mm) and excellent uniformity. Monitoring 1-yr stability, it revealed ∼1% change in timing, ±0.4% change in energy resolution, and <10% variations in T&H. CQIE PET gave <3% SUV variances in axial. 60%–100% recovery coefficients across sphere sizes and contrast levels were achieved. Conclusion: Characteristics and stability of the next generation DPC PET detector system over an 1-yr time window was excellent and

  2. SU-F-I-55: Performance Evaluation of Digital PET/CT: Medical Physics Basis for the Clinical Applications

    International Nuclear Information System (INIS)

    Zhang, J; Knopp, MV; Miller, M

    2016-01-01

    Purpose: Replacement of conventional PMT-based detector with next generation digital photon counting (DPC) detector is a technology leap for PET imaging. This study evaluated the performance and characteristics of the DPC system and its stability within a 1 year time window following its installation focusing on the medical physics basis for clinical applications. Methods: A digital PET/CT scanner using 1:1 coupling of 23,040 crystal: detector elements was introduced and became operational at OSU. We tested and evaluated system performance and characteristics using NEMA NU2-2012. System stabilities in timing resolution, energy resolution, detector temperature and humidity (T&H) were monitored over 1-yr. Timing, energy and spatial resolution were characterized across clinically relevant count rate range. CQIE uniformity PET and NEMA IEC-Body PET with hot spheres varying with sizes and contrasts were performed. PET reconstructed in standard(4mm), High(2mm) and Ultra-High(1mm) definitions were evaluated. Results: NEMA results showed PET spatial resolution (mm-FWHM) from 4.01&4.14 at 1cm to 5.82&6.17 at 20cm in transverse & axial. 322±3ps timing and 11.0% energy resolution were measured. 5.7kcps/MBq system sensitivity with 24kcps/MBq effective sensitivity was obtained. The peak-NECR was ∼171kcps with the effective peak-NECR >650kcps@50kBq/mL. Scatter fraction was ∼30%, and the maximum trues was >900kcps. NEMA IQ demonstrated hot sphere contrast ranging from ∼62%±2%(10mm) to ∼88%±2%(22mm), cold sphere contrast of ∼86%±2%(28mm) and ∼89%±3%(37mm) and excellent uniformity. Monitoring 1-yr stability, it revealed ∼1% change in timing, ±0.4% change in energy resolution, and <10% variations in T&H. CQIE PET gave <3% SUV variances in axial. 60%–100% recovery coefficients across sphere sizes and contrast levels were achieved. Conclusion: Characteristics and stability of the next generation DPC PET detector system over an 1-yr time window was excellent and

  3. Micro-CT of Carotid Arteries: A Tool for Experimental Studies

    International Nuclear Information System (INIS)

    Mohr, Andreas; Wenke, Ruediger; Roemer, Frank W.; Lynch, John A.; Gatzka, Christian; Priebe, Markus; Guermazi, Ali; Grigorian, Mikayel; Heller, Martin; Mueller-Huelsbeck, Stefan

    2004-01-01

    Micro-computed tomography (micro-CT) is a high-resolution, nondestructive tool for two- and three-dimensional imaging and quantification. The ability of this technique to assess atherosclerosis of the carotid artery was evaluated in three human cadaver samples based on the original axial acquisitions, multiplanar reconstructions and volume rendering techniques. Quantitative analysis included the calculation of: (1) the original lumen perimeter, original lumen area, plaque area, residual lumen area, calcified area and gross sectional area reduction of the vascular lumen from two-dimensional slices; (2) the total tissue volume, soft tissue volume and calcified tissue volume from the three-dimensional data set. This preliminary study demonstrates the potential of micro-CT as a supplementary method for the two- and three-dimensional ex vivo evaluation of carotid atherosclerosis

  4. Mediastinal and extrapleural fat hypertrophy in idiopathic pulmonary fibrosis on high-resolution CT: comparison with normal individuals

    International Nuclear Information System (INIS)

    Son, Kyu Ri; Lee, Hyun Ju; Lim, Kun Young; Lee, Chang Hyun; Goo, Jin Mo; Im, Jung Gi

    2004-01-01

    We wished to compare the amount of mediastinal and extrapleural fat on high resolution CT for patients with idiopathic pulmonary fibrosis (IPF) with that of normal individuals, and we wished to evaluate the correlation between the amount of fat and the degree of pulmonary fibrosis. We selected a group of 25 patients with radiologically and clinically diagnosed IPF and we also selected another group of 25 age and gender-matched patients having no abnormalities on pulmonary function testing as well as HRCT as controls from our radiologic database search (mean age: 59 years, M:F= 11:14). We measured the area of mediastinal and extrapleural fat at the levels of the aortic arch and at the origin of the right pulmonary artery and right inferior pulmonary vein on three sections of HRCT by using software (Rapidia; 3DMED, Seoul, Korea). The total amount of fat was calculated by summing up the areas of the mediastinal and extrapleural fat, which is corrected by the body mass index; we also evaluated statistical differences between the two groups. At same sections of CT, the ratio (%) of the honeycombing area to the total areas of the lung was calculated. We evaluated the relationship between the amount of extrapleural or mediastinal fat with the ratio (%) of the honeycombing area. The total amount of fat in patients with IPF and normal individuals were 67.24±19.03 cm 2 and 32.55±11.91 cm 2 , respectively. The fat amount corrected by body mass index was 280.48±74.43 mm 2 /kg/m 2 in the IPF patients and 137.06±41.76 mm 2 /kg/m 2 in normal individuals. The differences between two groups for the total amount of fat and fat amount, as corrected for by the body mass index, were statistically significant (p<0.0001). The ratio (%) of the honeycombing area and the total amount of fat showed a moderate correlation (rho= 0.43, p=0.032). Patients with IPF have a larger amount of mediastinal and extrapleural fat than normal individuals. The hypertrophy of mediastinal and extrapleural

  5. Mediastinal and extrapleural fat hypertrophy in idiopathic pulmonary fibrosis on high-resolution CT: comparison with normal individuals

    Energy Technology Data Exchange (ETDEWEB)

    Son, Kyu Ri; Lee, Hyun Ju; Lim, Kun Young; Lee, Chang Hyun; Goo, Jin Mo; Im, Jung Gi [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-12-01

    We wished to compare the amount of mediastinal and extrapleural fat on high resolution CT for patients with idiopathic pulmonary fibrosis (IPF) with that of normal individuals, and we wished to evaluate the correlation between the amount of fat and the degree of pulmonary fibrosis. We selected a group of 25 patients with radiologically and clinically diagnosed IPF and we also selected another group of 25 age and gender-matched patients having no abnormalities on pulmonary function testing as well as HRCT as controls from our radiologic database search (mean age: 59 years, M:F= 11:14). We measured the area of mediastinal and extrapleural fat at the levels of the aortic arch and at the origin of the right pulmonary artery and right inferior pulmonary vein on three sections of HRCT by using software (Rapidia; 3DMED, Seoul, Korea). The total amount of fat was calculated by summing up the areas of the mediastinal and extrapleural fat, which is corrected by the body mass index; we also evaluated statistical differences between the two groups. At same sections of CT, the ratio (%) of the honeycombing area to the total areas of the lung was calculated. We evaluated the relationship between the amount of extrapleural or mediastinal fat with the ratio (%) of the honeycombing area. The total amount of fat in patients with IPF and normal individuals were 67.24{+-}19.03 cm{sup 2} and 32.55{+-}11.91 cm{sup 2}, respectively. The fat amount corrected by body mass index was 280.48{+-}74.43 mm{sup 2}/kg/m{sup 2} in the IPF patients and 137.06{+-}41.76 mm{sup 2}/kg/m{sup 2} in normal individuals. The differences between two groups for the total amount of fat and fat amount, as corrected for by the body mass index, were statistically significant (p<0.0001). The ratio (%) of the honeycombing area and the total amount of fat showed a moderate correlation (rho= 0.43, p=0.032). Patients with IPF have a larger amount of mediastinal and extrapleural fat than normal individuals. The

  6. Comparative evaluation of the porta hepatis/hepatoduodenal ligament with CT and MR imaging

    International Nuclear Information System (INIS)

    Silverman, P.M.; Feuerstein, I.M.; Zeman, R.K.; Jaffe, M.H.; Garra, B.S.

    1988-01-01

    CT and MR imaging were compared in a retrospective evaluation of 16 patients with abnormalities, predominantly neoplasms, of the porta hepatis/hepatoduodenal ligament. Masses on CT were of decreased density compared with that of liver and were seen in contrast to surrounding periportal fat. On MR images, T1-weighted images demonstrated findings similar to those of CT. T2-weighted images clearly depicted intrahepatic lesions but less distinctly depicted lesions surrounded by fat. Short inversion recovery (STIR) images better demonstrated tumor relative to fat. CT was better than all MR imaging sequences in one of 16 cases, whereas at least one MR imaging sequence was better than CT in six of 16. In nine cases, CT was equivalent to the best MR imaging sequence. In five of six cases where MR imaging was better than CT, STIR sequences were most favorable. In conclusion, MR imaging provided a valuable technique for assessing abnormalities of the porta hepatis/hepatoduodenal ligament

  7. Normal anatomy of the lymphatic system in the CT-image

    International Nuclear Information System (INIS)

    Steinbrich, W.; Peters, P.E.

    1982-01-01

    To evaluate a pathologic process of a lymphatic node, detailed knowledge is required of the normal anatomy of the lumphatic system in an axial CT image. The anatomy is demonstrated in a comparative study before and after lymphography with CT-scans of patients with normal lymphadenographs. Hereby it appears that with the high-resolution scanning method and favourable imaging conditions even small lymphatic nodes can be differentiated without a lymphographic contrast technique. However, nerves and vessels cannot be differentiated. The extreme variability in the size of normal lymphatic nodes makes the differentiation of pathologic processes very difficult. (orig.) [de

  8. 18F-DOPA PET/CT and 68Ga-DOTANOC PET/CT scans as diagnostic tools in focal congenital hyperinsulinism: a blinded evaluation.

    Science.gov (United States)

    Christiansen, Charlotte Dahl; Petersen, Henrik; Nielsen, Anne Lerberg; Detlefsen, Sönke; Brusgaard, Klaus; Rasmussen, Lars; Melikyan, Maria; Ekström, Klas; Globa, Evgenia; Rasmussen, Annett Helleskov; Hovendal, Claus; Christesen, Henrik Thybo

    2018-02-01

    Focal congenital hyperinsulinism (CHI) is curable by surgery, which is why identification of the focal lesion is crucial. We aimed to determine the use of 18F-fluoro-dihydroxyphenylalanine (18F-DOPA) PET/CT vs. 68Ga-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic-acid-1-Nal3-octreotide (68Ga-DOTANOC) PET/CT as diagnostic tools in focal CHI. PET/CT scans of children with CHI admitted to Odense University Hospital between August 2005 and June 2016 were retrospectively evaluated visually and by their maximal standardized uptake values (SUV max ) by two independent examiners, blinded for clinical, surgical and pathological data. Pancreatic histology was used as the gold standard. For patients without surgery, the genetic profile served as the gold standard. Fifty-five CHI patients were examined by PET/CT (18F-DOPA n = 53, 68Ga-DOTANOC n = 18). Surgery was performed in 34 patients, no surgery in 21 patients. Fifty-one patients had a classifiable outcome, either by histology (n = 33, 22 focal lesions, 11 non-focal) or by genetics (n = 18, all non-focal). The predictive performance of 18F-DOPA PET/CT to identify focal CHI was identical by visual- and cut-off-based evaluation: sensitivity (95% CI) of 1 (0.85-1); specificity of 0.96 (0.82-0.99). The optimal 18F-DOPA PET SUV max ratio cut-off was 1.44 and the optimal 68Ga-DOTANOC PET SUV max cut-off was 6.77 g/ml. The area under the receiver operating curve was 0.98 (0.93-1) for 18F-DOPA PET vs. 0.71 (0.43-0.95) for 68Ga-DOTANOC PET (p PET/CT and 68Ga-DOTANOC PET/CT, respectively. 18F-DOPA PET/CT was excellent in predicting focal CHI and superior compared to 68Ga-DOTANOC PET/CT. Further use of 68GA-DOTANOC PET/CT in predicting focal CHI is discouraged.

  9. Third version of vendor-specific model-based iterativereconstruction (Veo 3.0): evaluation of CT image quality in the abdomen using new noise reduction presets and varied slice optimization.

    Science.gov (United States)

    Telesmanich, Morgan E; Jensen, Corey T; Enriquez, Jose L; Wagner-Bartak, Nicolaus A; Liu, Xinming; Le, Ott; Wei, Wei; Chandler, Adam G; Tamm, Eric P

    2017-08-01

    To qualitatively and quantitatively compare abdominal CT images reconstructed with a newversion of model-based iterative reconstruction (Veo 3.0; GE Healthcare Waukesha, WI) utilizing varied presetsof resolution preference, noise reduction and slice optimization. This retrospective study was approved by our Institutional Review Board and was Health Insurance Portability and Accountability Act compliant. The raw datafrom 30 consecutive patients who had undergone CT abdomen scanning were used to reconstructfour clinical presets of 3.75mm axial images using Veo 3.0: 5% resolution preference (RP05n), 5%noise reduction (NR05) and 40% noise reduction (NR40) with new 3.75mm "sliceoptimization," as well as one set using RP05 with conventional 0.625mm "slice optimization" (RP05c). The images were reviewed by two independent readers in a blinded, randomized manner using a 5-point Likert scale as well as a 5-point comparative scale. Multiple two-dimensional circular regions of interest were defined for noise and contrast-to-noise ratio measurements. Line profiles were drawn across the 7 lp cm -1 bar pattern of the Catphan 600 phantom for evaluation of spatial resolution. The NR05 image set was ranked as the best series in overall image quality (mean difference inrank 0.48, 95% CI [0.081-0.88], p = 0.01) and with specific reference to liver evaluation (meandifference 0.46, 95% CI [0.030-0.89], p = 0.03), when compared with the secondbest series ineach category. RP05n was ranked as the best for bone evaluation. NR40 was ranked assignificantly inferior across all assessed categories. Although the NR05 and RP05c image setshad nearly the same contrast-to-noise ratio and spatial resolution, NR05 was generally preferred. Image noise and spatial resolution increased along a spectrum with RP05n the highest and NR40the lowest. Compared to RP05n, the average noise was 21.01% lower for NR05, 26.88%lower for RP05c and 50.86% lower for NR40. Veo 3.0 clinical presets allow for

  10. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias; Scholz, Bernhard; Royalty, Kevin

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  11. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  12. CtGEM typing: Discrimination of Chlamydia trachomatis ocular and urogenital strains and major evolutionary lineages by high resolution melting analysis of two amplified DNA fragments.

    Science.gov (United States)

    Giffard, Philip M; Andersson, Patiyan; Wilson, Judith; Buckley, Cameron; Lilliebridge, Rachael; Harris, Tegan M; Kleinecke, Mariana; O'Grady, Kerry-Ann F; Huston, Wilhelmina M; Lambert, Stephen B; Whiley, David M; Holt, Deborah C

    2018-01-01

    Chlamydia trachomatis infects the urogenital tract (UGT) and eyes. Anatomical tropism is correlated with variation in the major outer membrane protein encoded by ompA. Strains possessing the ocular ompA variants A, B, Ba and C are typically found within the phylogenetically coherent "classical ocular lineage". However, variants B, Ba and C have also been found within three distinct strains in Australia, all associated with ocular disease in children and outside the classical ocular lineage. CtGEM genotyping is a method for detecting and discriminating ocular strains and also the major phylogenetic lineages. The rationale was facilitation of surveillance to inform responses to C. trachomatis detection in UGT specimens from young children. CtGEM typing is based on high resolution melting analysis (HRMA) of two PCR amplified fragments with high combinatorial resolving power, as defined by computerised comparison of 65 whole genomes. One fragment is from the hypothetical gene defined by Jali-1891 in the C. trachomatis B_Jali20 genome, while the other is from ompA. Twenty combinatorial CtGEM types have been shown to exist, and these encompass unique genotypes for all known ocular strains, and also delineate the TI and T2 major phylogenetic lineages, identify LGV strains and provide additional resolution beyond this. CtGEM typing and Sanger sequencing were compared with 42 C. trachomatis positive clinical specimens, and there were no disjunctions. CtGEM typing is a highly efficient method designed and tested using large scale comparative genomics. It divides C. trachomatis into clinically and biologically meaningful groups, and may have broad application in surveillance.

  13. Pre-operative evaluation of cleft palate using three dimensional computerized tomography (s-D CT)

    International Nuclear Information System (INIS)

    Azia, A.; Hashmi, R.

    1999-01-01

    Cleft palate is a congenital anomaly with major development concerns. Surgery with bone grafting is often required to correct the lesion. With the introduction of 3-D CT the evaluation of cleft pa late has become more accurate. We present two cases of cleft palate, which were operated upon with bone grafting. We employed 3-D CT techniques in addition to the conventional 2-D CT, 3-D CT improves the estimation of the required bone graft and signification reduces length of surgery and complications. (author)

  14. Image Quality Improvement after Implementation of a CT Accreditation Program

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Choi, Byung Gil; Shin, Yu Ri; Hwang, Seong Su; Ku, Young Mi; Lim, Yeon Soo; Lee, Jae Mun

    2010-01-01

    The purpose of this study was to evaluate any improvement in the quality of abdominal CTs after the utilization of the nationally based accreditation program. Approval was obtained from the Institutional Review Board, and informed consent was waived. We retrospectively analyzed 1,011 outside abdominal CTs, from 2003 to 2007. We evaluated images using a fill-up sheet form of the national accreditation program, and subjectively by grading for the overall CT image quality. CT scans were divided into two categories according to time periods; before and after the implementation of the accreditation program. We compared CT scans between two periods according to parameters pertaining to the evaluation of images. We determined whether there was a correlation between the results of a subjective assessment of the image quality and the evaluation scores of the clinical image. The following parameters were significantly different after the implementation of the accreditation program: identifying data, display parameters, scan length, spatial and contrast resolution, window width and level, optimal contrast enhancement, slice thickness, and total score. The remaining parameters were not significantly different between scans obtained from the two different periods: scan parameters, film quality, and artifacts. After performing the CT accreditation program, the quality of the outside abdominal CTs show marked improvement, especially for the parameters related to the scanning protocol

  15. Acute pulmonary schistosomiasis: Correlation between the high-resolution CT and pathological findings

    Directory of Open Access Journals (Sweden)

    Arthur Soares Souza, Jr.

    2007-09-01

    Full Text Available A 35 years old rural worker presented with a 15 days history of progressive dyspnea, associated with dry cough, mialgia and fever. Few days before the symptoms, he had swim in a river. The chest radiographs demonstrated bilateral reticule-nodular infiltrates. The high-resolution CT showed patchy areas of ground-glass attenuation, irregular interlobular septal thickening, intralobular interstitial thickening, and small nodules, which are confluent in some regions. All the laboratorial investigation were negative. The open lung biopsy shows parenchymal granulomatous inflammation, and numerous schistosome ova. Resumo: Paciente masculino, de 35 anos, trabalhador rural, apresentando-se com história de dispneia progressiva, tosse seca, mialgia e febre, com evolução de 15 dias. Relatava ter nadado num rio, recentemente. As radiografias de tórax mostravam infiltração retículo-nodular bilateral. A tomografia computadorizada de alta resolução evidenciava áreas esparsas de atenuação em vidro fosco, espessamento irregular de septos in- terlobulares e do interstício intralobular e pequenos nódulos, confluentes em algumas regiões. Os exames laboratoriais eram normais. Biópsia pulmonar a céu aberto demonstrou inflamação parenquimatosa granulomatosa, com presença de ovos de esquistossoma. Key-words: Acute schistosomiasis, high-resolution computed tomography, parasitic infection, lungs, Palavras-chave: Esquistossomose aguda, tomografia computadorizada de alta resolução, infecção parasitária, pulmões

  16. Evaluation of registration methods on thoracic CT : the EMPIRE10 challenge

    NARCIS (Netherlands)

    Murphy, K.; Ginneken, van B.; Reinhardt, J.M.; Kabus, S.; Ding, K.; Deng, Xiang; Cao, K.; Du, K.; Christensen, G.E.; Garcia, V.; Vercauteren, T.; Ayache, N.; Commowick, O.; Malandain, G.; Glocker, B.; Paragios, N.; Navab, N.; Gorbunova, V.; Sporring, J.; Bruijne, de M.; Han, Xiao; Heinrich, M.P.; Schnabel, J.A.; Jenkinson, M.; Lorenz, C.; Modat, M.; McClelland, J.R.; Ourselin, S.; Muenzing, S.E.A.; Viergever, M.A.; Nigris, De D.; Collins, D.L.; Arbel, T.; Peroni, M.; Li, R.; Sharp, G.; Schmidt-Richberg, A.; Ehrhardt, J.; Werner, R.; Smeets, D.; Loeckx, D.; Song, G.; Tustison, N.; Avants, B.; Gee, J.C.; Staring, M.; Klein, S.; Stoel, B.C.; Urschler, M.; Werlberger, M.; Vandemeulebroucke, J.; Rit, S.; Sarrut, D.; Pluim, J.P.W.

    2011-01-01

    EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intrapatient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This

  17. Role of X-ray CT in the evaluation of extension of ovarian cancer

    International Nuclear Information System (INIS)

    Saito, Takashi

    1991-01-01

    To evaluate the utility of X-ray computed tomography (CT) in the management of malignant ovarian tumor, preoperative CT of 89 patients with ovarian cancer were analyzed on the basis of their surgically confirmed findings. Relationships between CT findings and clinical factors such as actual tumor spread, stage, and accomplished surgery were studied. The results obtained were as follows. The rates of correct diagnosis in tumor spread were 79.8% for tumor growth on the external surface of the ovary, 77.6% for involvement of both ovaries, 79.8% for ascites, 78.2% for metastasis to the uterus, 68.2% for peritoneal metastasis, 77.0% for metastasis to the intestine, and 79.3% for the metastasis to the omentum. Comparing the stage suggested by CT (CT stage) and the stage revealed by surgery (surgical stage), the stages coincided in 57 patients (64.0%). CT stages were overestimated in 9 caces and underestimated in 23 caces. As for the practicability of surgery, either complete or standard operation was performed in 31 of 33 caces (93.9%) of CT stage I, 21 of 28 (75.0%) of CT stage II, and 11 of 28 (39.3%) of CT stage III. The possibility of accomplishing surgery was very low when CT indicated stage III disease. (author)

  18. Evaluation of Schmorl's nodes using F-18 FDG PET/CT

    International Nuclear Information System (INIS)

    Lin, C.-Y.; Chen, H.-Y.; Ding, H.-J.; Chen, Y.-K.; Kao, C.-H.

    2012-01-01

    Aim: To evaluate the image findings of Schmorl's nodes on combined 2-[ 18 F]-fluoro-2-deoxy-D-glucose positron-emission tomography/computed tomography (FDG PET/CT). Materials and methods: Twelve patients who were diagnosed with Schmorl's nodes and had undergone magnetic resonance imaging (MRI) and FDG PET/CT were retrospectively recruited for this study. The period between the MRI and the FDG PET/CT examinations was within 1 week. The demographic data and clinical history were reviewed. The relationship between MRI findings and the values of maximum standardized uptake value (SUVmax) on FDG PET/CT was analysed. Results: The mean values of early and delayed SUVmax of Schmorl's nodes without MRI enhancement were 1.14 ± 0.28 and 1.09 ± 0.32. The mean values of early and delayed SUVmax of Schmorl's nodes with MRI enhancement were 1.73 ± 0.49 and 1.75 ± 0.54. There were significant differences in the early and delayed SUVmax between Schmorl's nodes with and without perifocal enhancement on MRI with Wilcoxon's rank-sum test (p = 0.012; p = 0.006). There was a trend of positive correlation, although not statistically significant, between delayed SUVmax on FDG PET/CT and age in Schmorl's nodes with Spearman’s rank correlation (B = 0.86, p = 0.056). Conclusions: Schmorl's nodes demonstrated low to moderate uptake on FDG PET/CT images. Schmorl's nodes with perifocal enhancement on MRI result in higher FDG uptake. The possibility of false positives caused by Schmorl's nodes should be considered when interpreting FDG PET/CT images of bone metastases, especially in the aging population.

  19. The value of CT in the diagnosis of traumatic fronto-basal CSF fistulae

    International Nuclear Information System (INIS)

    Stoeter, P.; Ebeling, U.; Sankt Elisabethenkrankenhaus, Ravensburg

    1982-01-01

    In 20 patients with fronto-basal CSF fistulae, radiograms, tomograms and CTs in the axial and coronal projection were taken before operation. The evaluation showed that small fractures of the cribriform lamina could be demonstrated most clearly by CT with narrow coronal sections. Although the resolution properties of CT is still inferior to that of tomography for small osseous fissures, good CT results could be achieved by the better demonstration of accompanying mucosal swelling and/or small effusions. Fractures of the walls of the frontal sinuses, on the other hand, were shown better by tomography and those of the frontal calotte by normal radiograms. (orig.) [de

  20. Comparison of MR imaging and CT in the evaluation of uterine tumors

    International Nuclear Information System (INIS)

    Janus, C.L.; Dottino, P.; Brodman, M.; Goodman, H.; Gendal, E.S.; Rabinowitz, J.G.

    1987-01-01

    The authors compared the usefulness of MR imaging and CT in staging uterine tumors. Forty women with known cervical carcinoma, endometrial cancer, or leiomyosarcoma underwent CT and MR imaging within 1 week prior to surgery. MR imaging was better than CT for localizing tumors to the endometrium of myometrium and in the evaluation of lymph node involvement and extension to the cervix and parametria. MR imaging, with its superior ability to demonstrate pelvic anatomy and its lack of ionizing radiation and risk from iodinated contrast media, has an important place in the staging of uterine tumors

  1. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  2. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  3. Minimum intensity projection technique in the evaluation of pulmonary emphysema

    International Nuclear Information System (INIS)

    Ishii, Chikako; Tada, Shinpei; Fukuda, Kunihiko; Hayashi, Naganobu

    2000-01-01

    Clinically diagnosed 30 pulmonary emphysema patients were evaluated with helical CT. From 10 mm thickness and 10 mm/sec table speed helical CT date set, minimum intensity projection (Min-IP) were generated. Min-IP coronal images were well demonstrated distribution and degree of emphysema. Compared to the high resolution CT images (2 mm thickness), Min-IP images were as same as well evaluated the disease. Min-IP technique seem to be useful for evaluate distribution and degree of pulmonary emphysema. (author)

  4. Volumetry of human molars with flat panel-based volume CT in vitro

    NARCIS (Netherlands)

    Hannig, C.; Krieger, E.; Dullin, C.; Merten, H.A.; Attin, T.; Grabbe, E.; Heidrich, G.

    2006-01-01

    The flat panel-based volume computed tomography (fpVCT) is a new CT device applicable for experimental, three-dimensional evaluation of teeth at a resolution of about 150 microm in the high contrast region. The aim of this study was to investigate whether fpVCT was suitable for quantification of the

  5. High-resolution coded-aperture design for compressive X-ray tomography using low resolution detectors

    Science.gov (United States)

    Mojica, Edson; Pertuz, Said; Arguello, Henry

    2017-12-01

    One of the main challenges in Computed Tomography (CT) is obtaining accurate reconstructions of the imaged object while keeping a low radiation dose in the acquisition process. In order to solve this problem, several researchers have proposed the use of compressed sensing for reducing the amount of measurements required to perform CT. This paper tackles the problem of designing high-resolution coded apertures for compressed sensing computed tomography. In contrast to previous approaches, we aim at designing apertures to be used with low-resolution detectors in order to achieve super-resolution. The proposed method iteratively improves random coded apertures using a gradient descent algorithm subject to constraints in the coherence and homogeneity of the compressive sensing matrix induced by the coded aperture. Experiments with different test sets show consistent results for different transmittances, number of shots and super-resolution factors.

  6. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  7. Prospective evaluation of MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, H.A., E-mail: vargasah@mskcc.org [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Akin, O.; Schöder, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Olgac, S. [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Dalbagni, G. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hricak, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Bochner, B.H. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-12-15

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), {sup 11}C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, {sup 11}C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, {sup 11}C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  8. Micro-CT Pore Scale Study Of Flow In Porous Media: Effect Of Voxel Resolution

    Science.gov (United States)

    Shah, S.; Gray, F.; Crawshaw, J.; Boek, E.

    2014-12-01

    In the last few years, pore scale studies have become the key to understanding the complex fluid flow processes in the fields of groundwater remediation, hydrocarbon recovery and environmental issues related to carbon storage and capture. A pore scale study is often comprised of two key procedures: 3D pore scale imaging and numerical modelling techniques. The essence of a pore scale study is to test the physics implemented in a model of complicated fluid flow processes at one scale (microscopic) and then apply the model to solve the problems associated with water resources and oil recovery at other scales (macroscopic and field). However, the process of up-scaling from the pore scale to the macroscopic scale has encountered many challenges due to both pore scale imaging and modelling techniques. Due to the technical limitations in the imaging method, there is always a compromise between the spatial (voxel) resolution and the physical volume of the sample (field of view, FOV) to be scanned by the imaging methods, specifically X-ray micro-CT (XMT) in our case In this study, a careful analysis was done to understand the effect of voxel size, using XMT to image the 3D pore space of a variety of porous media from sandstones to carbonates scanned at different voxel resolution (4.5 μm, 6.2 μm, 8.3 μm and 10.2 μm) but keeping the scanned FOV constant for all the samples. We systematically segment the micro-CT images into three phases, the macro-pore phase, an intermediate phase (unresolved micro-pores + grains) and the grain phase and then study the effect of voxel size on the structure of the macro-pore and the intermediate phases and the fluid flow properties using lattice-Boltzmann (LB) and pore network (PN) modelling methods. We have also applied a numerical coarsening algorithm (up-scale method) to reduce the computational power and time required to accurately predict the flow properties using the LB and PN method.

  9. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  10. A rural CT scanner: evaluating the effect on local health care

    International Nuclear Information System (INIS)

    Merkens, B.J.; Mowbray, R.D.; Creeden, L.; Engels, P.T.; Rothwell, D.M.; Chan, B.T.B.; Tu, K.

    2006-01-01

    The first small rural hospital in Ontario to propose a computed tomography (CT) scanner was in Walkerton, a town 160 km north of London. The Ontario Ministry of Health approved the proposal as a pilot project to evaluate the effect on local health care of a rural scanner. This evaluation study had 3 parts: a survey of physicians, a survey of patients, and an analysis of population CT scanning rates. The physicians in the area served by the scanner were asked about its impact on their care of their patients in a mailed questionnaire and in semistructured interviews. Scanner outpatients were given a questionnaire in which they rated the importance of its advantages. The analysis of scanning rates--the ratio of number of scans to estimated population--compared rates in the area with other Ontario rates before and after the scanner was introduced. The physicians reported that local CT allowed them to diagnose and treat patients sooner, closer to home, and with greater confidence. On average, 75% of the patients ranked faster and closer access as very important. Scanning rates in the area rose, although they did not match urban rates. The study confirms that the rural scanner changed the area's health care in significant ways and that it helped to narrow the gap between rural and urban service levels. We recommend that CT be expanded to other rural regions. (author)

  11. SU-C-206-01: Impact of Charge Sharing Effect On Sub-Pitch Resolution for CZT-Based Photon Counting CT Systems

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, X; Cheng, Z; Deen, J; Peng, H [McMaster University, Hamilton, Ontario (Canada); Xing, L [Stanford University School of Medicine, Stanford, CA (United States)

    2016-06-15

    Purposes: Photon counting CT is a new imaging technology that can provide tissue composition information such as calcium/iodine content quantification. Cadmium zinc telluride CZT is considered a good candidate the photon counting CT due to its relatively high atomic number and band gap. One potential challenge is the degradation of both spatial and energy resolution as the fine electrode pitch is deployed (<50 µm). We investigated the extent of charge sharing effect as functions of gap width, bias voltage and depth-of-interaction (DOI). Methods: The initial electron cloud size and diffusion process were modeled analytically. The valid range of charge sharing effect refers to the range over which both signals of adjacent electrodes are above the triggering threshold (10% of the amplitude of 60keV X-ray photons). The intensity ratios of output in three regions (I1/I2/I3: left pixel, gap area and right pixel) were calculated. With Gaussian white noises modeled (a SNR of 5 based upon the preliminary experiments), the sub-pitch resolution as a function of the spatial position in-between two pixels was studied. Results: The valid range of charge sharing increases linearly with depth-of-interaction (DOI) but decreases with gap width and bias voltage. For a 1.5mm thickness CZT detector (pitch: 50µm, bias: 400 V), the range increase from ∼90µm up to ∼110µm. Such an increase can be attributed to a longer travel distance and the associated electron cloud broadening. The achievable sub-pitch resolution is in the range of ∼10–30µm. Conclusion: The preliminary results demonstrate that sub-pixel spatial resolution can be achieved using the ratio of amplitudes of two neighboring pixels. Such ratio may also be used to correct charge loss and help improve energy resolution of a CZT detector. The impact of characteristic X-rays hitting adjacent pixels (i.e., multiple interaction) on charge sharing is currently being investigated.

  12. PET-CT in the evaluation of sarcomas of soft tissues; PET-CT en la evaluacion de sarcomas de tejidos blandos

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J A; Quiroz C, O; Sanchez C, N; Diaz V, G [Hospital Angeles del Pedregal, Mexico D.F. (Mexico)

    2007-07-01

    {sup 18} F-FDG PET-CT is an image modality of great utility in the evaluation of primary or recurrent lesions of soft tissues. It is necessary to determine the cost-benefit of the different image modalities, although one waits that by means of a better diagnostic, statification and the determination of the grade of malignancy, the PET-CT nowadays can reduce the cost and the complications of the invasive diagnostic methods. (Author)

  13. [Rapid resolution of acute subdural haematoma with significant impact on clinical outcome].

    Science.gov (United States)

    Capion, Tenna; Lilja-Cyron, Alexander; Kelsen, Jesper

    2017-09-04

    A 73-year-old woman was admitted to hospital due to anaemia. She suffered a minor head trauma and deteriorated to deep unconsciousness. A CT revealed an acute subdural haematoma (ASDH). Initially, she was not found to be a candidate for neurosurgical intervention, but within 24 hours her level of consciousness improved dramatically, and a renewed CT showed resolution of the ASDH. She underwent acute craniotomy with good outcome. This illustrates the importance of re-evaluation of patients with intracranial haemorrhage.

  14. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  15. Solitary nodular bronchioloalveolar carcinoma of the lung: prediction of histology at high-resolution CT

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Lee, Kyung Soo; Choo, In Wook; Kim, Seung Hoon; Lee, Won Jae; Byun, Hong Sik; Kim, Yoo Kyung; Shin, Myung Hee; Kim, Sang Jin

    1998-01-01

    The purpose of this study is to descdribe the characteristic high-resolution (HR) CT findings of solitary nodular bronchioloalveolar carcinoma (BAC) of the lung which are valuable for specific diagnosis of the disease. HRCT scans of 46 patients (31 with malignant and 15 with benign lesion) with a solitary pulmonary nodule seen on chest radiograph were distributed in random order and analyzed retrospectively. Two blinded observers jointly analyzed the marginal and internal characteristics of nodules as seen on HRCT, and decisions on the findings were reached by consensus. Stepwise discriminant analysis for characteristic findings of BAC was performed. The most frequent CT findings of BAC (n=3D15) were internal bubble lucency (14/15, 93%)(p=3D0.001), area of ground-glass opacity (12/15, 80%; average 58% of tumor volume)(p=3D0.0001), pleural tag(12/15, 80%; p=3D0.097), and lobulated and spiculated margin(8/15, 53%; p=3D0.459). Findings of ground-glass opacity (p=3D0.0001) and bubble lucency (p=3D0.0187) appeared to be discriminant in the diagnosis of BAC. Peripheral pulmonary nodules containing an area of ground-glass opacity associated with internal bubble-lucency are characteristic of BAC. Specific histologic diagnosis of solitary nodular BAC can be suggested by careful analysis of HRCT findings.=20

  16. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  17. Computed tomography in the evaluation of thyroid disease

    International Nuclear Information System (INIS)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-01-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum

  18. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  19. Evaluation of cine CT in the investigation of patients with recurrent symptoms following coronary bypass grafting

    International Nuclear Information System (INIS)

    Rees, M.R.; MacMillan, R.M.; Eldredge, W.J.; Maranhao, V.

    1986-01-01

    Between May 1985 and July 1986, cine-CT was performed in 84 consecutive patients to evaluate graft patency and ventricular function. Only three studies (4%) were unsatisfactory. Compared to catheterization, an accuracy of 94% was found for graft patency, with a significant correlation for ejection fraction (r = .93). Close agreement with angiography was demonstrated for cine-CT detection of left ventricular wall motion abnormalities and graft flow. Compared to surgical placement, cine-CT localization of grafts in major coronary territories was 98% accurate. Despite a significant learning curve in study interpretation, cine-CT can be used in place of catheterization in the evaluation of symptomatic postgraft patients

  20. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients