Sample records for resolution bi-dimensional electrophoresis

  1. Enantiomeric resolution of multiple chiral centres racemates by capillary electrophoresis.

    Ali, Imran; Suhail, Mohd; Al-Othman, Zeid A; Alwarthan, Abdulrahman; Aboul-Enein, Hassan Y


    Enantiomeric resolution of multichiral centre racemates is an important area as some multichiral centre racemates are of great medicinal importance. However, enantioseparation of such types of racemates is a challenging task. Amongst many analytical techniques, capillary electrophoresis is a powerful technique and may be used to resolve such racemates. Only few papers are available describing enantiomeric resolution of such racemates. Therefore, efforts have been made to describe the enantiomeric resolution of multichiral centre racemates by capillary electrophoresis. This article discusses the importance of multichiral racemates, the need for capillary electrophoresis in enantiomeric resolution and chiral resolution of multichiral centre racemates using various chiral selectors. Further, attempts have been made to discuss the future challenges and prospects of enantiomeric resolution of multichiral racemates. The various chiral selectors used for the purpose are chiral crown ether, cyclodextrins, polysaccharides, macrocyclic glycopeptide antibiotics and ligand exchange.

  2. The new horizon in 2D electrophoresis: new technology to increase resolution and sensitivity.

    Moche, Martin; Albrecht, Dirk; Maaß, Sandra; Hecker, Michael; Westermeier, Reiner; Büttner, Knut


    A principally new type of an electrophoresis setup for the second dimension of 2DE named HPE (high performance electrophoresis) has recently become available that provides excellent reproducibility much superior to traditional 2DE. It takes up ideas from early beginnings of 2DE which could not be satisfactory realized at that time. The new HPE system is in contrast to all other established systems a horizontal electrophoresis that employs a new type of precast polyacrylamide gels on film-backing and runs on a multilevel flatbed electrophoresis apparatus. In a systematic approach we compared its features to traditional 2DE for the cytosolic proteome of Bacillus subtilis. Not only the reproducibility is enhanced, but also nearly all qualitative parameters as resolution, sensitivity, the number of protein spots (25% more), and the number of different proteins (also additional 25%) are markedly increased. More than 200 proteins were exclusively found in HPE. This new electrophoresis system does not use buffer tanks. No glass plates are needed. Therefore handling of gels is greatly facilitated and very simple to use even for personnel with low technical skills. The new HPE system is technically at the beginnings and further development with increased performance can be expected.

  3. Enhanced Resolution of DNA Separation Using Agarose Gel Electrophoresis Doped with Graphene Oxide

    Li, Jialiang; Yang, Yushi; Mao, Zhou; Huang, Wenjie; Qiu, Tong; Wu, Qingzhi


    In this work, a novel agarose gel electrophoresis strategy has been developed for separation of DNA fragments by doping graphene oxide (GO) into agarose gel. The results show that the addition of GO into agarose gel significantly improved the separation resolution of DNA fragments by increasing the shift distances of both the single DNA fragments and the adjacent DNA fragments and completely eliminating the background noise derived from the diffusion of the excessive ethidium bromide (EB) dye in the gel after electrophoresis. The improved resolution of DNA fragments in GO-doped agarose gel could be attributed to the successive adsorption-desorption processes between DNA fragments and GO sheets, while the elimination of the background noise could be attributed to the adsorption of the excessive EB dye on the surface of GO sheets and high fluorescence quenching efficiency of GO. These results provide promising potential for graphene and its derivate utilized in various electrophoresis techniques for separation and detection of DAN fragments and other biomolecules.

  4. On Bi-Dimensional Second µ-Variation

    Ereú Jurancy


    Full Text Available In this paper, we present a generalization of the notion of bounded slope variation for functions defined on a rectangle Iba in ℝ2. Given a strictly increasing function µ-defined in a closed real interval, we introduce the class BVµ,2 (Iba , of functions of bounded second µ-variation on Iba ; and show that this class can be equipped with a norm with respect to which it is a Banach space. We also deal with the important case of factorizable functions in BVµ,2 (Iba and finally we exhibit a relation between this class and the one of double Riemann-Stieltjes integrals of functions of bi-dimensional bounded variation.

  5. Heat string model of bi-dimensional dc Glidarc

    Pellerin, S.; Richard, F.; Chapelle, J.; Cormier, J.-M.; Musiol, K.


    The gliding arc discharge (`Glidarc') is the subject of renewed interest in application to a variety of chemical reactions. The gliding arc creates a weakly ionized gas `string' between two horn-shaped electrodes. In this paper, we present a simple model for a bi-dimensional dc Glidarc working in air, in which the conducting zone of the discharge that is heated by the Joule effect is considered as a hot wire cooled by an air flow. Inside this wire, the heat transfer results from thermal conduction. The exchange of heat between the hot wire and the air flow is assured by convection and depends on the wire radius and the relative velocity of the arc with respect to the gas flow. The model correctly describes experimental results and allows us to predict the working parameters of the Glidarc in different experimental situations.

  6. Organization of the Sec61 translocon, studied by high resolution native electrophoresis.

    Dejgaard, Kurt; Theberge, Jean-Francois; Heath-Engel, Hannah; Chevet, Eric; Tremblay, Michel L; Thomas, David Y


    Cotranslational translocation of polypeptides into the ER is controlled by the dynamic interaction of ribosome and translocon components. Analysis of the steps involved in this process by high resolution techniques such as gel electrophoresis is precluded by the high molecular masses of these complexes. We show, here, that modifications to standard native electrophoresis protocols can overcome these problems and lead to an increase in mass range and resolution. Using the modified technique, we show that ER ribosome anchored membrane protein (RAMP) complexes resolve into 3 stable and semistable complexes which range in size between 4 and 8 MDa and are sensitive to relevant concentrations of divalent metals. We demonstrate the molecular composition of the complexes and identify a number of modular components that differentiate them. The components that are common to all three RAMP complexes include the OST translocon subcomplex, Glucosidase I and microtubule tethering protein CLIMP63. The two larger complexes further include the kinesin motor binding protein p180 and Sec61, and the largest complex includes the TRAP translocon component and apoptotic regulator BAP31. On the lumenal side, the BiP cochaperone ERdj3 resides with the three RAMP complexes. Our observations may hint at how subcompartmentalization is achieved in the ER membrane continuum.

  7. Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry

    Moini, Mehdi; Rollman, Christopher M.


    We introduce a battery operated capillary electrophoresis electrospray ionization (CE/ESI) source for mass spectrometry with optical isomer separation capability. The source fits in front of low or high resolution mass spectrometers similar to a nanospray source with about the same weight and size. The source has two high voltage power supplies (±25 kV HVPS) capable of operating in forward or reverse polarity modes and powered by a 12 V rechargeable lithium ion battery with operation time of ~10 h. In ultrafast CE mode, in which short narrow capillaries (≤15 μm i.d., 15-25 cm long) and field gradients ≥1000 V/cm are used, peak widths at the base are <1 s wide. Under these conditions, the source provides high resolution separation, including optical isomer resolution in ~1 min. Using a low resolution mass spectrometer (LTQ Velos) with a scan time of 0.07 s/scan, baseline separation of amino acids and their optical isomers were achieved in ~1 min. Moreover, bovine serum albumin (BSA) was analyzed in ~1 min with 56% coverage using the data-dependent MS/MS. Using a high resolution mass spectrometer (Thermo Orbitrap Elite) with 15,000 resolution, the fastest scan time achieved was 0.15 s, which was adequate for CE-MS analysis when optical isomer separation is not required or when the optical isomers were well separated. Figures of merit including a detection limit of 2 fmol and linear dynamic range of two orders of magnitude were achieved for amino acids.

  8. Rapid high-resolution characterization of functionally important monoclonal antibody N-glycans by capillary electrophoresis.

    Szabo, Zoltan; Guttman, András; Bones, Jonathan; Karger, Barry L


    Characterization of the N-glycosylation present in the Fc region of therapeutic monoclonal antibodies requires rapid, high-resolution separation methods to guarantee product safety and efficacy during all stages of process development. Determination of fucosylated oligosaccharides is particularly important during clone selection, product characterization, and lot release as fucose has been shown to adversely affect the ability of mAbs to induce antibody dependent cellular cytotoxicity (ADCC). Here, we apply a general capillary electrophoresis optimization strategy to separate functionally relevant fucosylated and afucosylated glycans on mononclonal antibody products in the presence of several high mannose oligosaccharides. The N-glycans chosen represent those most commonly reported on CHO cell derived therapeutic antibodies. A rapid (processing for automated 96 well plate-based glycosylation analyses of two nonproprietary therapeutic monoclonal antibodies, demonstrating ruggedness and suitability for high-throughput process and product monitoring applications.

  9. Flow counterbalanced capillary electrophoresis using packed capillary columns: resolution of enantiomers and isotopomers.

    Henley, W Hampton; Wilburn, Richard T; Crouch, Andrew M; Jorgenson, James W


    A method with the ability to increase greatly both the resolution and efficiency of a given capillary electrophoretic system is described. This method differs from traditional capillary electrophoresis (CE) in that a counterflow is induced in the direction opposite to the electrokinetic migration of the analyte. This has the effect of extending not only the time the analytes migrate in the electric field but also the effective length and the effective applied voltage of the system. Previous work in our group with flow counterbalanced capillary electrophoresis has utilized an open tube of small inner diameter to reduce peak broadening caused by hydrodynamic flow. Narrow-diameter capillaries (5-10 microm) restricted analysis to fluorescent analytes and laser-induced fluorescence detection. The method described here uses a capillary of much larger inner diameter (75 microm) that has been packed with nonporous silica particles. The packing material reduces the amount of band broadening caused by pressure-induced flow relative to that experienced in an open tube. A larger diameter capillary allows the detection of analytes by UV absorption, not only eliminating the need to tag analytes with fluorescent tags but also allowing for the detection of a much broader range of analytes. The system was evaluated by studying the separations of several enantiomers using only beta-cyclodextrin as the chiral selector. The system was also used to resolve the two naturally occurring isotopes of bromine and to resolve phenylalanine from phenylalanine-d8. Relative to traditional CE, large improvements in resolution and separation efficiency have been achieved with this method.

  10. High resolution clear native electrophoresis is a good alternative to blue native electrophoresis for the characterization of the Escherichia coli membrane complexes.

    Diéguez-Casal, Ernesto; Freixeiro, Paula; Costoya, Liliana; Criado, M Teresa; Ferreirós, Carlos; Sánchez, Sandra


    Blue native electrophoresis (BNE) has become the most popular method for the global analysis of membrane protein complexes. Although it has been shown to be very useful for that purpose, it can produce the dissociation of complexes with weak interactions and, due to the use of Coomassie Brilliant Blue, does not allow the subsequent application of fluorimetric and/or enzymatic techniques. Recently, we have successfully used the high resolution clear native electrophoresis (hrCNE) for the analysis of Neisseria meningitidis outer membrane porin complexes. The aim of this study was to determine the composition of the complexome of the Escherichia coli envelope by using hrCNE and to compare our results with those previously obtained using BNE. The bidimensional electrophoresis approaches used, hrCN/hrCNE and hrCN/SDS-PAGE, coupled to mass spectrometry allowed a detailed analysis of the complexome of E. coli membranes. For the first time, the three subunits of the formate dehydrogenase FDH-O were identified forming a single complex and hrCNE also allowed the identification of both the HflK and HflC proteins as components of the HflA complex. This technique also allowed us to suggest a relationship between OmpF and DLDH and, although OmpA is considered to be monomeric in vivo, we found this protein structured as homodimers. Thus hrCNE provides a good tool for future analyses of bacterial membrane proteins and complexes and is an important alternative to the commonly used BNE.

  11. Assessment of resolution and intercenter reproducibility of results of genotyping Staphylococcus aureus by pulsed-field gel electrophoresis of SmaI macrorestriction fragments: a multicenter study

    A.F. van Belkum (Alex); S. Salmenlinna; M. Kooistra; B. Cookson (Barry); W. Witte; N. El Solh; F. Forey; J. Etienne (Jerome); R. Goering; A. Morvan; M. Struelens; J. Vuopio-Varkila; F.C. Tenover (Fred); C. Steward; N. Legakis; A. Talens; F. O'Brien (Frances); P. Tassios; R. de Ryck; W. Grubb; M.E. Kaufmann; H.A. Verbrugh (Henri); W.B. van Leeuwen (Willem)


    textabstractTwenty well-characterized isolates of methicillin-resistant Staphylococcus aureus were used to study the optimal resolution and interlaboratory reproducibility of pulsed-field gel electrophoresis (PFGE) of DNA macrorestriction fragments. Five identical

  12. Analyzing genetic diversity in conifers...isozyme resolution by starch gel electrophoresis

    M. Thompson Conkle


    Enzymes in forest tree materials can be resolved by starch gel electrophoresis. A gel slab is prepared in a mold assembled from glass and plastic. Wicks containing an aqueous extract of macerated plant material are inserted in the gel and processed. The gel is sliced, stained, examined, and photographed. Isozyme bands produced by differential migration of enzymes...

  13. High Resolution Microsatellite Marker Analysis of Some Rice Landraces Using Metaphor Agarose Gel Electrophoresis

    K. Kristamtini; T. Taryono; Panjisakti Basunanda; Rudi Hari Murti


    Microsatellite markers or simple sequences repeats are DNA - based molecular techniques that are used to see the different among accessions and inbred lines. There are three methods to analysis the results of the polymerase chain reaction of microsatellite markers namely polyacrylamide gel electrophoresis (PAGE), capillary electroforesis, and Metaphor Agarose Gel Electroforesis (MAGE), and the Use of MAGE assessed more easily and economically the polymorphic pattern of DNA markers...

  14. Electrophoresis technology

    Snyder, R. S.


    A new high resolution apparatus designed for space was built as a laboratory prototype. Using a moving wall with a low zeta potential coating, the major sources of flow distortion for an electrophoretic sample stream are removed. Highly resolved fractions, however, will only be produced in space because of the sensitivity of this chamber to buoyancy-induced convection in the laboratory. The second and third flights of the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system carried samples developed at MSFC intended to evaluate the broad capabilities of free flow electrophoresis in a reduced gravity environment. Biological model materials, hemoglobin and polystyrene latex microspheres, were selected because of their past use as electrophoresis standards and as visible markers for fluid flow due to electroosmosis, spacecraft acceleration or other factors. The dependence of the separation resolution on the properties of the sample and its suspension solution was assessed.

  15. Quantitative investigation of resolution increase of free-flow electrophoresis via simple interval sample injection and separation.

    Shao, Jing; Fan, Liu-Yin; Cao, Cheng-Xi; Huang, Xian-Qing; Xu, Yu-Quan


    Interval free-flow zone electrophoresis (FFZE) has been used to suppress sample band broadening greatly hindering the development of free-flow electrophoresis (FFE). However, there has been still no quantitative study on the resolution increase of interval FFZE. Herein, we tried to make a comparison between bandwidths in interval FFZE and continuous one. A commercial dye with methyl green and crystal violet was well chosen to show the bandwidth. The comparative experiments were conducted under the same sample loading of the model dye (viz. 3.49, 1.75, 1.17, and 0.88 mg/h), the same running time (viz. 5, 10, 15, and 20 min), and the same flux ratio between sample and background buffer (= 10.64 × 10⁻³). Under the given conditions, the experiments demonstrated that (i) the band broadening was evidently caused by hydrodynamic factor in continuous mode, and (ii) the interval mode could clearly eliminate the hydrodynamic broadening existing in continuous mode, greatly increasing the resolution of dye separation. Finally, the interval FFZE was successfully used for the complete separation of two-model antibiotics (herein pyoluteorin and phenazine-1-carboxylic acid coexisting in fermentation broth of a new strain Pseudomonas aeruginosa M18), demonstrating the feasibility of interval FFZE mode for separation of biomolecules.

  16. Multiplex and quantitative pathogen detection with high-resolution capillary electrophoresis-based single-strand conformation polymorphism.

    Hwang, Hee Sung; Shin, Gi Won; Chung, Boram; Na, Jeongkyeong; Jung, Gyoo Yeol


    Among the molecular diagnostic methods for bacteria-induced diseases, capillary electrophoresis-based single-strand conformation polymorphism (CE-SSCP) combined with 16S rRNA gene-specific PCR has enormous potential because it can separate sequence variants using a simple procedure. However, conventional CE-SSCP systems have limited resolution and cannot separate most 16S rRNA gene-specific markers into separate peaks. A high-resolution CE-SSCP system that uses a poly(ethyleneoxide)-poly(propyleneoxide)-poly(ethyleneoxide) triblock copolymer matrix was recently developed and shown to effectively separate highly similar PCR products. In this report, a protocol for the detection of 12 pathogenic bacteria is provided. Pathogen markers were amplified by PCR using universal primers and separated by CE-SSCP; each marker peak was well separated at baseline and showed a characteristic mobility, allowing the easy identification of the pathogens.

  17. Buffer optimization for high resolution of human lung cancer tissue proteins by two-dimensional gel electrophoresis.

    Lee, Kibeom; Pi, Kyungbae; Lee, Keeman


    A problem in proteomic analysis of lung cancer tissue is the presence of complex components of different histological backgrounds (squamous cell carcinoma, small cell lung carcinoma, and adenocarcinoma). The efficient solubilization of protein components before two-dimensional electrophoresis (2-DE) is a very critical. Poor solubilization has been associated with a failure to detect proteins and diffuse, streaked and/or trailing protein spots. Here, we have optimized the solubilization of human lung cancer tissue to increase protein resolution. Isoelectric focusing (IEF) rehydration buffer containing a thiourea-urea mixture provided superior resolution, whereas a buffer without thiourea yielded consistently poor results. In addition, IEF rehydration buffers containing CHAPS and DTT gave superior resolution, whereas buffers containing Nonidet P-40 (NP-40) and/or Triton X-100 did not. A tributylphosphine-containing buffer gave consistently poor results. Using optimized conditions, we used 2-D gel analysis of human lung cancer tissue to identify 11 differentially-expressed protein spots by MALDI-mass spectrometry. This study provides a methodological tool to study the complex mammalian proteomes.

  18. Chiral resolution of basic drugs by capillary electrophoresis with new glycosaminoglycans.

    Tsukamoto, T; Ushio, T; Haginaka, J


    New glycosaminoglycans, fucose-containing glycosaminoglycan (FGAG) and depolymerized holothurian glycosaminoglycan (DHG), were investigated as chiral additives for the separation of drug enantiomers by capillary electrophoresis. The average molecular masses of FGAG and DHG were estimated to be about 59,000 and 14,000, respectively. A variety of basic drug enantiomers were resolved using 10 mM phosphate buffer, pH 5.0, containing 3% FGAG or DHG. Since chiral recognition properties of FGAG and DHG are different, some drug enantiomers were only separated by using FGAG or DHG. With regard to comparison of chiral recognition abilities of FGAG and DHG with other chiral selectors, tolperisone and eperisone enantiomers were not separated with alpha- or beta-cyclodextrin, or heparin as the chiral additives, but were separated with FGAG and DHG. The results obtained reveal that FGAG and DHG are useful as the chiral selectors for separations of drug enantiomers by CE, and that they could be complementarily used with other chiral additives.

  19. "Leucine aminopeptidase" (neutral arylamidase) in sheep sera: improved resolution with gradient gel electrophoresis.

    Manwell, C; Baker, C M


    Electrophoretic resolution of the heterogeneity of sheep serum "leucine aminopeptidase" is greatly improved by the use of gradients of acrylamide polymer, together with enzyme localisation involving L-alanyl beta-naphthylamide and cobaltous ion. The improved resolution contradicts an earlier claim of the existence of only two patterns of individual variation in the heterogeneity of sheep serum "leucine aminopeptidase", with one pattern completely dominant to the other. While the sheep enzyme is unusual among mammalian serum "leucine aminopeptidases" in its complex heterogeneity, it does conform to the typical mammalian pattern of codominant individual variation. The complexity of sheep serum "leucine aminopeptidase" is useful in the study of sheep evolution.

  20. Improved Electrophoresis Cell

    Rhodes, P. H.; Snyder, R. S.


    Several proposed modifications are expected to improve performance of a continous-flow electrophoresis cell. Changes would allow better control of buffer flow and would increase resolution by suppressing thermal gradients. Improved electrophoresis device would have high resolution and be easy to operate. Improvements would allow better flow control and heat dissipation.

  1. Resolution and identification of major peanut allergens using a combination of fluorescence two-dimensional differential gel electrophoresis, western blotting and Q-TOF mass spectrometry.

    Peanut allergy is triggered by several proteins known as allergens. The matching resolution and identification of major peanut allergens in 2D protein maps, was accomplished by the use of fluorescence two-dimensional differential gel electrophoresis (2D DIGE), Western blotting and quadrupole time-of...

  2. Velocity gap mode of capillary electrophoresis developed for high-resolution chiral separations.

    Li, Xue; Li, Youxin; Zhao, Lumeng; Shen, Jianguo; Zhang, Yong; Bao, James J


    A new CE method based on velocity gap (VG) theory has been developed for high-resolution chiral separations. In VG, two consecutive electric fields are adopted to drive analytes passing through two capillaries, which are linked together through a joint. The joint is immersed inside another buffer vial which has conductivity communication with the buffer inside the capillary. By adjusting the field strengths onto the two capillaries, it is possible to observe different velocities of an analyte when it passes through those two capillaries and there would be a net velocity change (NVC) for the same analyte. Different analytes may have different NVC which may be specifically meaningful for enantioseparations because enantiomers are usually hard to resolve. By taking advantage of this NVC, it is possible to enhance the resolution of a chiral separation if a proper voltage program is applied. The feasibility of using NVC to enhance chiral separation was demonstrated in the separations of three pairs of enantiomers: terbutaline, chlorpheniramine, and promethazine. All separations started with partial separation in a conventional CE and were significantly improved under the same experimental conditions. The results indicated that VG has the potential to be used to improve the resolving power of CE in chiral separations.

  3. Protein Electrophoresis/Immunofixation Electrophoresis

    ... be limited. Home Visit Global Sites Search Help? Protein Electrophoresis Immunofixation Electrophoresis Share this page: Was this page helpful? Also known as: Serum Protein Electrophoresis; Protein ELP; SPE; SPEP; Urine Protein Electrophoresis; ...

  4. SAR image change detection algorithm based on stationary wavelet and bi-dimensional intrinsic mode function

    Huang, S. Q.; Wang, Z. L.; Xie, T. G.; Li, Z. C.


    Speckle noise in synthetic aperture radar (SAR) image is produced by the coherent imaging mechanism, which brings a great impact on the change information acquisition of multi-temporal SAR images. Two-dimensional stationary wavelet transform (SWT) and bi-dimensional empirical mode decomposition (BEMD) are the non-stationary signal processing theory of multi-scale transform. According to their implementation process and SAR image characteristic, this paper proposed a new multi-temporal SAR image change detection method based on the combination of the stationary wavelet transform and the bi-dimensional intrinsic mode function (BIMF) features, called SWT-BIMF algorithm. The contribution of the new algorithm includes two aspects. One is the design of the two selections of decomposition features, that is, the speckle noise filtering; another is the selected features to perform the enhance processing, so more effective change information will obtain. The feasibility of the SWT-BIMF algorithm is verified by the measured SAR image data, and good experimental results are obtained.

  5. Dereplication of known nucleobase and nucleoside compounds in natural product extracts by capillary electrophoresis-high resolution mass spectrometry.

    Chen, Junhui; Shi, Qian; Wang, Yanlong; Li, Zhaoyong; Wang, Shuai


    Nucleobase and nucleoside compounds exist widely in various organisms. An often occurring problem in the discovery of new bioactive compounds from natural products is reisolation of known nucleobase and nucleoside compounds. To resolve this problem, a capillary electrophoresis-high resolution mass spectrometry (CE-HR-MS) method providing both rapid separation and accurate mass full-scan MS data was developed for the first time to screen and dereplicate known nucleobase and nucleoside compounds in crude extracts of natural products. Instrumental parameters were optimized to obtain optimum conditions for CE separation and electrospray ionization-time-of-flight mass spectrometry (ESI-TOF/MS) detection. The proposed method was verified to be precise, reproducible, and sensitive. Using this method, known nucleobase and nucleoside compounds in different marine medicinal organisms including Syngnathus acus Linnaeus; Hippocampus japonicus Kaup and Anthopleura lanthogrammica Berkly were successfully observed and identified. This work demonstrates that CE-HR-MS combined with an accurate mass database may be used as a powerful tool for dereplicating known nucleobase and nucleoside compounds in different types of natural products. Rapid dereplication of known nucleobase and nucleoside compounds allows researchers to focus on other leads with greater potential to yield new substances.

  6. Dereplication of Known Nucleobase and Nucleoside Compounds in Natural Product Extracts by Capillary Electrophoresis-High Resolution Mass Spectrometry

    Junhui Chen


    Full Text Available Nucleobase and nucleoside compounds exist widely in various organisms. An often occurring problem in the discovery of new bioactive compounds from natural products is reisolation of known nucleobase and nucleoside compounds. To resolve this problem, a capillary electrophoresis-high resolution mass spectrometry (CE-HR-MS method providing both rapid separation and accurate mass full-scan MS data was developed for the first time to screen and dereplicate known nucleobase and nucleoside compounds in crude extracts of natural products. Instrumental parameters were optimized to obtain optimum conditions for CE separation and electrospray ionization-time-of-flight mass spectrometry (ESI-TOF/MS detection. The proposed method was verified to be precise, reproducible, and sensitive. Using this method, known nucleobase and nucleoside compounds in different marine medicinal organisms including Syngnathus acus Linnaeus; Hippocampus japonicus Kaup and Anthopleura lanthogrammica Berkly were successfully observed and identified. This work demonstrates that CE-HR-MS combined with an accurate mass database may be used as a powerful tool for dereplicating known nucleobase and nucleoside compounds in different types of natural products. Rapid dereplication of known nucleobase and nucleoside compounds allows researchers to focus on other leads with greater potential to yield new substances.

  7. Locus of Control revisited: development of a new bi-dimensional measure

    Javier Suárez-Álvarez

    Full Text Available Locus of control (LOC has a long tradition in Psychology, and various instruments have been designed for its measurement. However, the dimensionality of the construct is unclear, and still gives rise to considerable controversy. The aim of the present work is to present new evidence of validity in relation to the dimensionality of LOC. To this end, we developed a new measurement instrument with 23 items. The sample was made up of 697 Spanish participants, of whom 57.5% were women (M=22.43; SD= 9.19. The results support the bi-dimensionality of LOC: internal (α=.87 and external (α=.85. Furthermore, both subscales have shown adequate validity evidence in relation to self-efficacy, achievement motivation and optimism (r xy> .21. Statistically significant differences were found by sex (p < .05: men scored higher in external LOC and women in internal LOC. The validity evidence supports a two-dimensional structure for the LOC, and the measurement instrument developed showed adequate psychometric properties.

  8. Semi-crosslinked polyacrylamides as high-resolution and dynamic self-coating sieving matrices for protein capillary electrophoresis

    ZHOU Jin; XU JianDong; XIE Yao; QU Feng; DENG YuLin; GENG LiNa


    This paper describes non-gel capillary sieving electrophoresis employing semi-crosslinked poly-acrylamide as a high performance and low viscous replaceable separation matrix for separation of non-denatured protein separation. Arising from the fine sieving and dynamic coating ability of this polymer, a mixture of basic proteins lysozyme, cytochrome C, ribonuclease A, and trypsin was resolved with excellent reproducibility. Mixing different semi-crosslinked polyacrylamides together further im-proves the separation. The separtion mechanism was analyzed. With network structure developed to an intermediate state between crosslinked gel and linear polymer solutions, these semi-crosslinked polyacrylamide polymers demonstrate a promise as a new class of size sieving separation medium, not only in capillary electrophoresis, but also in microfluidic chip separation schemes.

  9. Automated screening system for retinal health using bi-dimensional empirical mode decomposition and integrated index.

    Acharya, U Rajendra; Mookiah, Muthu Rama Krishnan; Koh, Joel E W; Tan, Jen Hong; Bhandary, Sulatha V; Rao, A Krishna; Fujita, Hamido; Hagiwara, Yuki; Chua, Chua Kuang; Laude, Augustinus


    Posterior Segment Eye Diseases (PSED) namely Diabetic Retinopathy (DR), glaucoma and Age-related Macular Degeneration (AMD) are the prime causes of vision loss globally. Vision loss can be prevented, if these diseases are detected at an early stage. Structural abnormalities such as changes in cup-to-disc ratio, Hard Exudates (HE), drusen, Microaneurysms (MA), Cotton Wool Spots (CWS), Haemorrhages (HA), Geographic Atrophy (GA) and Choroidal Neovascularization (CNV) in PSED can be identified by manual examination of fundus images by clinicians. However, manual screening is labour-intensive, tiresome and time consuming. Hence, there is a need to automate the eye screening. In this work Bi-dimensional Empirical Mode Decomposition (BEMD) technique is used to decompose fundus images into 2D Intrinsic Mode Functions (IMFs) to capture variations in the pixels due to morphological changes. Further, various entropy namely Renyi, Fuzzy, Shannon, Vajda, Kapur and Yager and energy features are extracted from IMFs. These extracted features are ranked using Chernoff Bound and Bhattacharyya Distance (CBBD), Kullback-Leibler Divergence (KLD), Fuzzy-minimum Redundancy Maximum Relevance (FmRMR), Wilcoxon, Receiver Operating Characteristics Curve (ROC) and t-test methods. Further, these ranked features are fed to Support Vector Machine (SVM) classifier to classify normal and abnormal (DR, AMD and glaucoma) classes. The performance of the proposed eye screening system is evaluated using 800 (Normal=400 and Abnormal=400) digital fundus images and 10-fold cross validation method. Our proposed system automatically identifies normal and abnormal classes with an average accuracy of 88.63%, sensitivity of 86.25% and specificity of 91% using 17 optimal features ranked using CBBD and SVM-Radial Basis Function (RBF) classifier. Moreover, a novel Retinal Risk Index (RRI) is developed using two significant features to distinguish two classes using single number. Such a system helps to reduce eye

  10. Application of random amplified polymorphic DNA (RAPD) analysis coupled with microchip electrophoresis for high-resolution identification of Monascus strains.

    Shinzato, Naoya; Namihira, Tomoyuki; Tamaki, Yasutomo; Tsukahara, Masatoshi; Matsui, Toru


    Monascus fungi are commonly used for a variety of food products in Asia, and are also known to produce some biologically active compounds. Since the use of Monascus is expected to increase in food industries, strain-level identification and management of Monascus will be needed in the near future. In the present study, random amplified polymorphic DNA (RAPD) analysis coupled with microchip electrophoresis was applied for this purpose. Evaluations of the analysis stability revealed that reproducible results could be obtained, although template DNA fragmentation could influence the resulting RAPD pattern. RAPD analysis using 15 Monascus strains consisting of four species, M. ruber, M. pilosus, M. purpureus, and M. kaoliang showed that each strain generated a unique RAPD pattern, which allows strain-level identification of Monascus. In addition, the phylogenetic tree constructed from RAPD patterns reflected M. ruber-M. pilosus and M. purpureus-M. kaoliang clusters inferred from both ITS and beta-tubulin gene sequences, which indicated that the RAPD pattern could reflect their phylogenetic traits to a certain extent. On the other hand, RAPD analysis did not support the monophyletic clustering of the four Monascus species used in this study, which suggests the necessity of reexamination of species boundaries in Monascus.

  11. Theoretical modelling of a bi-dimensional U-shaped surface plasmon resonance based fibre optic sensor for sensitivity enhancement

    Verma, R K; Gupta, B D [Physics Department, Indian Institute of Technology Delhi, New Delhi-110016 (India)], E-mail:


    Theoretical analysis of a surface plasmon resonance based fibre optic sensor with a uniform semi-metal coated U-shaped probe is carried out using a bi-dimensional model. All the rays of the p-polarized light launched in the fibre and their electric vectors are assumed to be confined in the plane of bending of the U-shaped probe. The effect of the bending radius of the probe on the sensitivity of the sensor is studied. The study shows that as the bending radius of the probe decreases the sensitivity of the sensor increases. For the light launching conditions used, the maximum sensitivity achieved is several times more than that reported for a fibre optic tapered probe. In addition to high sensitivity, the most advantageous feature of a U-shaped probe is that it can be used as a point sensor.

  12. Rapid and high-resolution distinction of community-acquired and nosocomial Staphylococcus aureus isolates with identical pulsed-field gel electrophoresis patterns and spa types.

    Glasner, Corinna; Sabat, Artur J; Dreisbach, Annette; Larsen, Anders R; Friedrich, Alexander W; Skov, Robert L; van Dijl, Jan Maarten


    Methicillin-resistant Staphylococcus aureus (MRSA) represent a serious threat for public health worldwide. Of particular concern is the emergence of community-acquired MRSA, which is often difficult to distinguish from nosocomial MRSA due to a lack of suitable typing methods for early detection. For example, the USA300 pulsed-field gel electrophoresis (PFGE) pattern includes both the 'classical' community-acquired USA300 clone with spa type t008 and an epidemiologically unrelated nosocomial clone with spa type t024. Likewise, spa typing cannot distinguish the classic USA300 from nosocomial MRSA with the spa type t008. Since the fast and high-resolution distinction of these S. aureus types is important for infection prevention and surveillance, we investigated whether multiple-locus variable number tandem repeat fingerprinting (MLVF) can be applied to overcome these limitations. Indeed, MLVF correctly grouped 91 MRSA isolates belonging to the classic USA300 lineage, nosocomial MRSA isolates with the USA300 PFGE profile and spa type t024, and nosocomial MRSA isolates with spa type t008 into 3 distinct clusters. Importantly, several sub-clusters were also identified, reflecting epidemiological relationships between the respective isolates. We conclude that MLVF has the discriminatory power needed to rapidly distinguish very similar community-acquired and nosocomial MRSA isolates and that MLVF-based sub-clustering of isolates is highly useful for epidemiological investigations, outbreak prevention, and control. Copyright © 2012 Elsevier GmbH. All rights reserved.

  13. High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detection.

    Parrot, Sandrine; Sauvinet, Valérie; Riban, Véronique; Depaulis, Antoine; Renaud, Bernard; Denoroy, Luc


    A method for high temporal resolution monitoring of five neurotransmitters, dopamine (DA), noradrenaline (NA), gamma-aminobutyric acid (GABA), glutamate (Glu), l-aspartate (L-Asp), in freely-moving rats using microdialysis and capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD) was developed. An on-line device, including microdialysis and derivatization with naphthalene-2,3-dicarboxaldehyde, mixes the dialysate with derivatization reagents directly in the collection tube, i.e. with no reactor. Thereafter, collected derivatized samples are analyzed off-line with an automated CE system coupled to a LIFD using a 442 nm excitation. The sampling time was limited by the minimal volume required for the analysis by the automated CE system used: neurotransmitters could be determined in 667 nl dialysates (940 nl after derivatization), i.e. in samples collected every 20 s with a flow rate of 2 microl/min. The detection limits at the dialysis probe were 3 x 10(-9), 1 x 10(-9), 1.9 x 10(-8), 4.2 x 10(-7), 2.1 x 10(-7) mol/l for DA, NA, GABA, Glu and L-Asp, respectively. The protocol was validated using in vitro/in vivo tests and the performances--repeatability, linearity, characteristics of the probes--were determined. Finally, the high temporal resolution allowed the simultaneous monitoring of these neurotransmitters in rats with genetic absence epilepsy and revealed, for the first time, increases in GABA concentrations concomitantly with the seizures, detected when our new microdialysis method was combined to electroencephalographic recordings.

  14. On the bi-dimensional variational decomposition applied to nonstationary vibration signals for rolling bearing crack detection in coal cutters

    Jiang, Yu; Li, Zhixiong; Zhang, Chao; Hu, Chao; Peng, Z.


    This work aims to detect rolling bearing cracks using a variational approach. An original method that appropriately incorporates bi-dimensional variational mode decomposition (BVMD) into discriminant diffusion maps (DDM) is proposed to analyze the nonstationary vibration signals recorded from the cracked rolling bearings in coal cutters. The advantage of this variational decomposition based diffusion map (VDDM) method in comparison to the current DDM is that the intrinsic vibration mode of the crack can be filtered into a limited bandwidth in the frequency domain with an estimated central frequency, thus discarding the interference signal components in the vibration signals and significantly improving the crack detection performance. In addition, the VDDM is able to simultaneously process two-channel sensor signals to reduce information leakage. Experimental validation using rolling bearing crack vibration signals demonstrates that the VDDM separated the raw signals into four intrinsic modes, including one roller vibration mode, one roller cage vibration mode, one inner race vibration mode, and one outer race vibration mode. Hence, reliable fault features were extracted from the outer race vibration mode, and satisfactory crack identification performance was achieved. The comparison between the proposed VDDM and existing approaches indicated that the VDDM method was more efficient and reliable for crack detection in coal cutter rolling bearings. As an effective catalyst for rolling bearing crack detection, this newly proposed method is useful for practical applications.

  15. A bi-dimensional genome scan for prolificacy traits in pigs shows the existence of multiple epistatic QTL

    Bidanel Jean P


    Full Text Available Abstract Background Prolificacy is the most important trait influencing the reproductive efficiency of pig production systems. The low heritability and sex-limited expression of prolificacy have hindered to some extent the improvement of this trait through artificial selection. Moreover, the relative contributions of additive, dominant and epistatic QTL to the genetic variance of pig prolificacy remain to be defined. In this work, we have undertaken this issue by performing one-dimensional and bi-dimensional genome scans for number of piglets born alive (NBA and total number of piglets born (TNB in a three generation Iberian by Meishan F2 intercross. Results The one-dimensional genome scan for NBA and TNB revealed the existence of two genome-wide highly significant QTL located on SSC13 (P SSC17 (P P P P P Conclusions The complex inheritance of prolificacy traits in pigs has been evidenced by identifying multiple additive (SSC13 and SSC17, dominant and epistatic QTL in an Iberian × Meishan F2 intercross. Our results demonstrate that a significant fraction of the phenotypic variance of swine prolificacy traits can be attributed to first-order gene-by-gene interactions emphasizing that the phenotypic effects of alleles might be strongly modulated by the genetic background where they segregate.

  16. Supported Molecular Matrix Electrophoresis.

    Matsuno, Yu-Ki; Kameyama, Akihiko


    Mucins are difficult to separate using conventional gel electrophoresis methods such as SDS-PAGE and agarose gel electrophoresis, owing to their large size and heterogeneity. On the other hand, cellulose acetate membrane electrophoresis can separate these molecules, but is not compatible with glycan analysis. Here, we describe a novel membrane electrophoresis technique, termed "supported molecular matrix electrophoresis" (SMME), in which a porous polyvinylidene difluoride (PVDF) membrane filter is used to achieve separation. This description includes the separation, visualization, and glycan analysis of mucins with the SMME technique.

  17. Kidney Cell Electrophoresis

    Todd, P.


    Materials and procedures for microgravity electrophoresis of living human embryonic kidney cells were evaluated, ground support in the form of analytical cell electrophoresis and flow cytometry was provided and cells returned from space flight were analyzed. Preflight culture media, electrophoresis buffer, fraction collection media, temperature profiles, and urokinase assay procedures were tested prior to flight. Electrophoretic mobility distributions of aliquots of the cell population to be fractionated in flight were obtained. The protocol established and utilized is given.

  18. Affinity in electrophoresis.

    Heegaard, Niels H H


    The journal Electrophoresis has greatly influenced my approaches to biomolecular affinity studies. The methods that I have chosen as my main tools to study interacting biomolecules--native gel and later capillary zone electrophoresis--have been the topic of numerous articles in Electrophoresis. Below, the role of the journal in the development and dissemination of these techniques and applications reviewed. Many exhaustive reviews on affinity electrophoresis and affinity CE have been published in the last few years and are not in any way replaced by the present deliberations that are focused on papers published by the journal.

  19. Enantiomeric resolution of galanthamine and related drugs used in anti-Alzheimer therapy by means of capillary zone electrophoresis employing derivatized cyclodextrin selectors.

    Rizzi, A; Schuh, R; Brückner, A; Cvitkovich, B; Kremser, L; Jordis, U; Fröhlich, J; Küenburg, B; Czollner, L


    An analytical assay is presented for the determination of the enantiomeric composition of galanthamine and related synthetic and natural compounds. (-)-Galanthamine is isolated from Galanthus nivalis and is used in this optical pure form in the therapy of Alzheimer's disease. Recent efforts for a total synthesis of unichiral (-)-galanthamine is connected with the need for a fast and reliable assay for the determination of the optical purity of the end product, as well as for optimizing and controlling the final steps in total synthesis particularly the asymmetric transformation of narwedine. In this paper the enantiomeric resolution of these compounds is reported employing a capillary electrophoretic system with beta-cyclodextrin derived chiral selectors. With the proposed system a number of galanthamine and narwedine derived analogous compounds could be separated, including 1-bromo- and N-alkyl-substituted compounds.

  20. Electrophoresis for biological production

    Mccreight, L. R.


    Preparative electrophoresis may provide a unique method for meeting ever more stringent purity requirements. Prolonged near zero gravity in space may permit the operation of preparative electrophoresis equipment with 100 times greater throughput than is currently available. Some experiments with influenza Virus Antigen, Erythropoietin and Antihemophaliac Factor, along with process and economic projections, are briefly reviewed.

  1. Implementation of Online Preconcentration and Microsecond Time Resolution to Capillary Electrophoresis Single Particle Inductively Coupled Plasma Mass Spectrometry (CE-SP-ICP-MS) and Its Application in Silver Nanoparticle Analysis.

    Mozhayeva, Darya; Strenge, Ingo; Engelhard, Carsten


    Capillary electrophoresis (CE) coupled to single particle inductively coupled plasma mass-spectrometry (SP-ICP-MS) was used for the first time with a prototype data acquisition (μsDAQ) system that features 5 μs time resolution (100% duty cycle) to separate and quantify mixtures of silver nanoparticles (Ag NPs). Additionally, an online preconcentration technique, reversed electrode polarity stacking mode (REPSM), was applied for Ag NPs analysis with CE-SP-ICP-MS for the first time. After optimization, best results were achieved using a injection time of 110 s and a constant pressure of 50 mbar in hydrodynamic injection mode. It was possible to detect 14.3 ± 1.5× more 20 nm sized, 21.0 ± 4.2× more 40 nm sized, and 27.7 ± 4.9× more 60 nm sized Ag NPs compared to the standard injection time of only 3 s. The effect of applied voltage on the NPs separation was studied, and a CE separation at 20 kV was found to be optimal for the present setup. The capability of CE-SP-ICP-MS for quantification of particle number concentration was investigated, and detection limits in the submicrogram-per-liter range were achieved. The possibility to separate 20, 40, and 60 nm sized Ag NPs simultaneously present in a mixture was demonstrated over a broad concentration range.

  2. Binary Oscillatory Crossflow Electrophoresis

    Molloy, Richard F.; Gallagher, Christopher T.; Leighton, David T., Jr.


    Electrophoresis has long been recognized as an effective analytic technique for the separation of proteins and other charged species, however attempts at scaling up to accommodate commercial volumes have met with limited success. In this report we describe a novel electrophoretic separation technique - Binary Oscillatory Crossflow Electrophoresis (BOCE). Numerical simulations indicate that the technique has the potential for preparative scale throughputs with high resolution, while simultaneously avoiding many problems common to conventional electrophoresis. The technique utilizes the interaction of an oscillatory electric field and a transverse oscillatory shear flow to create an active binary filter for the separation of charged protein species. An oscillatory electric field is applied across the narrow gap of a rectangular channel inducing a periodic motion of charged protein species. The amplitude of this motion depends on the dimensionless electrophoretic mobility, alpha = E(sub o)mu/(omega)d, where E(sub o) is the amplitude of the electric field oscillations, mu is the dimensional mobility, omega is the angular frequency of oscillation and d is the channel gap width. An oscillatory shear flow is induced along the length of the channel resulting in the separation of species with different mobilities. We present a model that predicts the oscillatory behavior of charged species and allows estimation of both the magnitude of the induced convective velocity and the effective diffusivity as a function of a in infinitely long channels. Numerical results indicate that in addition to the mobility dependence, the steady state behavior of solute species may be strongly affected by oscillating fluid into and out of the active electric field region at the ends of the cell. The effect is most pronounced using time dependent shear flows of the same frequency (cos((omega)t)) flow mode) as the electric field oscillations. Under such conditions, experiments indicate that

  3. Environmental screening of acidic compounds based on capillary zone electrophoresis/laser-induced fluorescence detection with identification by gas chromatography/mass spectrometry and gas chromatography/high-resolution mass spectrometry.

    Brumley, W C; Grange, A H; Kelliher, V; Patterson, D B; Montcalm, A; Glassman, J; Farley, J W


    This paper describes the application of capillary zone electrophoresis/laser-induced fluorescence detection (CZE/LIF) to the discovery of acidic compounds in environmental matrixes or the screening of extracts for acidic components. Published studies indicate that coal-derived materials contain a significant fraction of acidic compounds relative to materials derived from petroleum and shales. Such compounds may be useful as marker compounds for site assessment and source apportionment issues, and their identification may be important in toxicological and other health issues. We used deep-UV light from the frequency-doubled Ar ion laser at 244 and 257 nm to study extracts of samples. The CZE/LIF technique possesses good sensitivity and therefore overcomes one of the limitations of CZE with UV detection. The present work depends on high pressure/temperature solvent extraction of polynuclear aromatic hydrocarbon (PNA)-contaminated soil, followed by separation using CZE. The anionic analytes were separated by using borate or phosphate buffer (pH 9.2-12.3) after a chemical class separation. Samples were also characterized by gas chromatography/mass spectrometry (GC/MS) using full scans at low resolution, and elemental compositions were determined unequivocally by GC/high-resolution MS (GC/HRMS) using mass peak profiling (MPP). The similarity of low-resolution electron ionization mass spectra for a standard, 1-hydroxypyrene, and for a series of compounds in a contaminated-soil extract suggested that several types of phenolic and hydroxy-PNAs were present, including hydroxylated derivatives of fluorenes, fluoranthenes, and pyrenes. GC/HRMS using MPP confirmed the elemental compositions of the hydroxyfluorenes and hydroxypyrenes (and presumably hydroxyfluoranthenes) as [C13H10O] and [C16H10O], respectively. A new version of the MPP software was written for the Finnigan-MAT 900S-Trap and was similar to that developed previously for the VG 250SE. Inclusion of a calibration


    anodically with generally better resolution than is evident for the cathodically-migrating components. Salivary amylase , a troublesome factor in the starch -gel electrophoresis of saliva proteins, does not attack acrylamide gel.

  5. Protein electrophoresis - serum

    ... this page: // Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  6. Urine protein electrophoresis test

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  7. Shaping Crystals using Electrophoresis

    Palacci, Jeremie; Mackiewicz, Kristian


    Electrophoresis is size and shape independent as stressed by Morrison in his seminal paper. Here we present an original approach to reshape colloidal crystals using an electric field as a carving tool.

  8. Electrophoresis operations in space

    Richman, D. W.


    Application of electrophoresis in space processing is described. Spaceborne experiments in areas such as biological products and FDA approved drugs are discussed. These experiments will be carried on shuttle payloads.

  9. Label-free Quantification of Proteins in Single Embryonic Cells with Neural Fate in the Cleavage-Stage Frog (Xenopus laevis) Embryo using Capillary Electrophoresis Electrospray Ionization High-Resolution Mass Spectrometry (CE-ESI-HRMS).

    Lombard-Banek, Camille; Reddy, Sushma; Moody, Sally A; Nemes, Peter


    Quantification of protein expression in single cells promises to advance a systems-level understanding of normal development. Using a bottom-up proteomic workflow and multiplexing quantification by tandem mass tags, we recently demonstrated relative quantification between single embryonic cells (blastomeres) in the frog (Xenopus laevis) embryo. In this study, we minimize derivatization steps to enhance analytical sensitivity and use label-free quantification (LFQ) for single Xenopus cells. The technology builds on a custom-designed capillary electrophoresis microflow-electrospray ionization high-resolution mass spectrometry platform and LFQ by MaxLFQ (MaxQuant). By judiciously tailoring performance to peptide separation, ionization, and data-dependent acquisition, we demonstrate an ∼75-amol (∼11 nm) lower limit of detection and quantification for proteins in complex cell digests. The platform enabled the identification of 438 nonredundant protein groups by measuring 16 ng of protein digest, or embryo. LFQ intensity was validated as a quantitative proxy for protein abundance. Correlation analysis was performed to compare protein quantities between the embryo and n = 3 different single D11 blastomeres, which are fated to develop into the nervous system. A total of 335 nonredundant protein groups were quantified in union between the single D11 cells spanning a 4 log-order concentration range. LFQ and correlation analysis detected expected proteomic differences between the whole embryo and blastomeres, and also found translational differences between individual D11 cells. LFQ on single cells raises exciting possibilities to study gene expression in other cells and models to help better understand cell processes on a systems biology level.

  10. Recent advances in preparative electrophoresis

    Mosher, Richard A.; Thormann, Wolfgang; Egen, Ned B.; Couasnon, Pascal; Sammons, David W.


    Various approaches for preparative electrophoresis, and three new instruments for preparative electrophoresis are discussed. Consideration is given to isoelectric focusing, isotachophoresis, and zone electrophoresis, three gel-based electrophoresis methods. The design, functions, and performance of the Elphor VaP 21 device of Hannig (1982), the shear-stabilized BIOSTREAM separator of Thompson (1983), and the recycling isoelectric focusing device are described.

  11. Lie algebraic approach to the time-dependent quantum general harmonic oscillator and the bi-dimensional charged particle in time-dependent electromagnetic fields

    Ibarra-Sierra, V.G.; Sandoval-Santana, J.C. [Departamento de Física, Universidad Autónoma Metropolitana Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 México D.F. (Mexico); Cardoso, J.L. [Área de Física Teórica y Materia Condensada, Universidad Autónoma Metropolitana Azcapotzalco, Av. San Pablo 180, Col. Reynosa-Tamaulipas, Azcapotzalco, 02200 México D.F. (Mexico); Kunold, A., E-mail: [Área de Física Teórica y Materia Condensada, Universidad Autónoma Metropolitana Azcapotzalco, Av. San Pablo 180, Col. Reynosa-Tamaulipas, Azcapotzalco, 02200 México D.F. (Mexico)


    We discuss the one-dimensional, time-dependent general quadratic Hamiltonian and the bi-dimensional charged particle in time-dependent electromagnetic fields through the Lie algebraic approach. Such method consists in finding a set of generators that form a closed Lie algebra in terms of which it is possible to express a quantum Hamiltonian and therefore the evolution operator. The evolution operator is then the starting point to obtain the propagator as well as the explicit form of the Heisenberg picture position and momentum operators. First, the set of generators forming a closed Lie algebra is identified for the general quadratic Hamiltonian. This algebra is later extended to study the Hamiltonian of a charged particle in electromagnetic fields exploiting the similarities between the terms of these two Hamiltonians. These results are applied to the solution of five different examples: the linear potential which is used to introduce the Lie algebraic method, a radio frequency ion trap, a Kanai–Caldirola-like forced harmonic oscillator, a charged particle in a time dependent magnetic field, and a charged particle in constant magnetic field and oscillating electric field. In particular we present exact analytical expressions that are fitting for the study of a rotating quadrupole field ion trap and magneto-transport in two-dimensional semiconductor heterostructures illuminated by microwave radiation. In these examples we show that this powerful method is suitable to treat quadratic Hamiltonians with time dependent coefficients quite efficiently yielding closed analytical expressions for the propagator and the Heisenberg picture position and momentum operators. -- Highlights: •We deal with the general quadratic Hamiltonian and a particle in electromagnetic fields. •The evolution operator is worked out through the Lie algebraic approach. •We also obtain the propagator and Heisenberg picture position and momentum operators. •Analytical expressions for a

  12. Pulse Field Gel Electrophoresis.

    Sharma-Kuinkel, Batu K; Rude, Thomas H; Fowler, Vance G


    Pulse Field Gel Electrophoresis (PFGE) is a powerful genotyping technique used for the separation of large DNA molecules (entire genomic DNA) after digesting it with unique restriction enzymes and applying to a gel matrix under the electric field that periodically changes direction. PFGE is a variation of agarose gel electrophoresis that permits analysis of bacterial DNA fragments over an order of magnitude larger than that with conventional restriction enzyme analysis. It provides a good representation of the entire bacterial chromosome in a single gel with a highly reproducible restriction profile, providing clearly distinct and well-resolved DNA fragments.




    During this year we performed two major projects: I. We developed a detailed theoretical model which complements our experiments on surface DNA electrophoresis. We found that it was possible to enhance the separation of DNA chains by imposing a chemical nanoscale pattern on the surface. This approach utilized the surface interaction effect of the DNA chains with the substrate and is a refinement to our previous method in which DNA chains were separated on homogeneous flat surfaces. By introducing the nano-patterns on the surface, the conformational changes of DNA chains of different lengths can be amplified, which results in the different friction strengths with the substrate surface. Our results also show that, when compared to the DNA electrophoresis performed on homogeneous flat surfaces, nanopatterned surfaces offer a larger window in choosing different surface interactions to achieve separation. II. In collaboration with a large international manufacturer of skin care products we also embarked on a project involving photo toxicity of titanium dioxide nanoparticles, which are a key ingredient in sunscreen and cosmetic lotions. The results clearly implicated the nanoparticles in catalyzing damage to chromosomal DNA. We then used this knowledge to develop a polymer/anti-oxidant coating which prevented the photocatalytic reaction on DNA while still retaining the UV absorptive properties of the nanoparticles. The standard gel electrophoresis was not sufficient in determining the extent of the DNA damage. The conclusions of this study were based predominantly on analysis obtained with the surface electrophoresis method.

  14. DNA gel electrophoresis: the reptation model(s).

    Slater, Gary W


    DNA gel electrophoresis has been the most important experimental tool to separate DNA fragments for several decades. The introduction of PFGE in the 1980s and capillary gel electrophoresis in the 1990s made it possible to study, map and sequence entire genomes. Explaining how very large DNA molecules move in a gel and why PFGE is needed to separate them has been an active field of research ever since the launch of the journal Electrophoresis. This article presents a personal and historical overview of the development of the theory of gel electrophoresis, focusing on the reptation model, the band broadening mechanisms, and finally the factors that limit the read length and the resolution of electrophoresis-based sequencing systems. I conclude with a short discussion of some of the questions that remain unanswered.

  15. Practical capillary electrophoresis

    Weinberger, Robert


    In the 1980s, capillary electrophoresis (CE) joined high-performance liquid chromatography (HPLC) as the most powerful separation technique available to analytical chemists and biochemists. Published research using CE grew from 48 papers in the year of commercial introduction (1988) to 1200 in 1997. While only a dozen major pharmaceutical and biotech companies have reduced CE to routine practice, the applications market is showing real or potential growth in key areas, particularly in the DNA marketplace for genomic mapping and forensic identification. For drug development involving small molecules (including chiral separations), one CE instrument can replace 10 liquid chromatographs in terms of speed of analysis. CE also uses aqueous rather than organic solvents and is thus environmentally friendlier than HPLC. The second edition of Practical Capillary Electrophoresis has been extensively reorganized and rewritten to reflect modern usage in the field, with an emphasis on commercially available apparatus and ...

  16. Electrophoresis experiments in microgravity

    Snyder, Robert S.; Rhodes, Percy H.


    The use of the microgravity environment to separate and purify biological cells and proteins has been a major activity since the beginning of the NASA Microgravity Science and Applications program. Purified populations of cells are needed for research, transplantation and analysis of specific cell constituents. Protein purification is a necessary step in research areas such as genetic engineering where the new protein has to be separated from the variety of other proteins synthesized from the microorganism. Sufficient data are available from the results of past electrophoresis experiments in space to show that these experiments were designed with incomplete knowledge of the fluid dynamics of the process including electrohydrodynamics. However, electrophoresis is still an important separation tool in the laboratory and thermal convection does limit its performance. Thus, there is a justification for electrophoresis but the emphasis of future space experiments must be directed toward basic research with model experiments to understand the microgravity environment and fluid analysis to test the basic principles of the process.

  17. Preparative electrophoresis for space

    Rhodes, Percy H.; Snyder, Robert S.


    A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

  18. Bis-Indole Derivatives for Polysaccharide Compositional Analysis and Chiral Resolution of D-, L-Monosaccharides by Ligand Exchange Capillary Electrophoresis Using Borate-Cyclodextrin as a Chiral Selector

    Wen-Bin Yang


    Full Text Available A series of aldo-bis-indole derivatives (aldo-BINs was prepared by aromatic C-alkylation reactions of aldoses and indole in acetic acid solution. Common monosaccharides such as glucose, mannose, galactose, fucose, xylose, rhamnose, ribose, arabinose and N-acetylglucosamine were smoothly derivatized to form the UV absorbing aldo-BINs. The use of a capillary electrophoretic method to separate these novel aldo-BIN derivatives was established. The capillary electrophoresis conditions were set by using borate buffer (100 mM at high pH (pH 9.0. The limit of determination was assessed to be 25 nM. The enantioseparation of D, L-pairs of aldo-BINs based on chiral ligand-exchange capillary electrophoresis technology was also achieved by using modified hydroxypropyl-β-cyclodextrin as the chiral selector in the presence of borate buffer. This aldose labeling method was applied successfully to the compositional and configurational analysis of saccharides, exemplified by a rapid and efficient method to simultaneously analyze the composition and configuration of saccharides from the medicinal herbs Cordyceps sinensis and Dendrobium huoshanense.

  19. Derivatization in Capillary Electrophoresis.

    Marina, M Luisa; Castro-Puyana, María


    Capillary electrophoresis is a well-established separation technique in analytical research laboratories worldwide. Its interesting advantages make CE an efficient and potent alternative to other chromatographic techniques. However, it is also recognized that its main drawback is the relatively poor sensitivity when using optical detection. One way to overcome this limitation is to perform a derivatization reaction which is intended to provide the analyte more suitable analytical characteristics enabling a high sensitive detection. Based on the analytical step where the CE derivatization takes place, it can be classified as precapillary (before separation), in-capillary (during separation), or postcapillary (after separation). This chapter describes the application of four different derivatization protocols (in-capillary and precapillary modes) to carry out the achiral and chiral analysis of different compounds in food and biological samples with three different detection modes (UV, LIF, and MS).

  20. Combined effect of tobacco smoking and alcohol drinking in the risk of head and neck cancers: a re-analysis of case-control studies using bi-dimensional spline models.

    Dal Maso, Luigino; Torelli, Nicola; Biancotto, Elisa; Di Maso, Matteo; Gini, Andrea; Franchin, Gianni; Levi, Fabio; La Vecchia, Carlo; Serraino, Diego; Polesel, Jerry


    The synergistic effect of tobacco smoking and alcohol consumption on the risk of head and neck cancers has been mainly investigated as a cross-product of categorical exposure, thus leading to loss of information. We propose a bi-dimensional logistic spline model to investigate the interacting dose-response relationship of two continuous exposures (i.e., ethanol intake and tobacco smoking) on the risk of head and neck cancers, representing results through three-dimensional graphs. This model was applied to a pool of hospital-based case-control studies on head and neck cancers conducted in Italy and in the Vaud Swiss Canton between 1982 and 2000, including 1569 cases and 3147 controls. Among never drinkers and for all levels of ethanol intake, the risk of head and neck cancers steeply increased with increasing smoking intensity, starting from 1 cigarette/day. The risk associated to ethanol intake increased with incrementing exposure among smokers, and a threshold effect at approximately 50 g/day emerged among never smokers. Compared to abstainers from both tobacco and alcohol consumption, the combined exposure to ethanol and/or cigarettes led to a steep increase of cancer risk up to a 35-fold higher risk (95 % confidence interval 27.30-43.61) among people consuming 84 g/day of ethanol and 10 cigarettes/day. The highest risk was observed at the highest levels of alcohol and tobacco consumption. Our findings confirmed a combined effect of tobacco smoking and alcohol drinking on head and neck cancers risk, providing evidence that bi-dimensional spline models could be a feasible and flexible method to explore the pattern of risks associated to two interacting continuous-exposure variables.

  1. High-resolution genotyping of Listeria monocytogenes by fluorescent amplified fragment length polymorphism analysis compared to pulsed-field gel electrophoresis, random amplified polymorphic DNA analysis, ribotyping, and PCR-restriction fragment length polymorphism analysis

    Vogel, Birte Fonnesbech; Fussing, V.; Ojeniyi, B.


    of different origin. The AFLP technique was compared with three other molecular typing methods - ribotyping, random amplified polymorphic DNA analysis (RAPD), and pulsed-field gel electrophoresis (PFGE) - in terms of discriminatory ability. PCR-restriction fragment length polymorphism was included......The purpose of this study was to evaluate fluorescent amplified fragment length polymorphism (AFLP) analysis for the inter- and intraspecies differentiation of a collection of 96 strains of Listeria monocytogenes and 10 non- L. monocytogenes strains representing six other Listeria species...... for virulence gene allele characterization. The 96 L. monocytogenes strains were divided into two major clusters by AFLP fingerprinting at a similarity level of 82% in concordance with the results of PFGE, RAPD, and ribotyping. One main cluster consisted of all of the 24 L. monocytogenes hly allele 1 strains...

  2. Bag model for DNA migration during pulsed-field electrophoresis.

    Chu, G


    A model for pulsed-field electrophoresis was developed by picturing large DNA as a deformable "bag" that (i) moves with limiting mobility in a continuous electric field, (ii) adopts an orientation aligned with the field direction, and (iii) reorients after a change in field direction in a size-dependent manner. The model correctly predicted the resolution of large DNA in a pulsed field including the surprising phenomena of mobility inversion, lateral band spreading, and improved resolution fo...

  3. Monitoring Homovanillic Acid and Vanillylmandelic Acid in Human Urine by Capillary Electrophoresis with Electrochemical Detection


    A simple, rapid and low-cost method of separation and determination of homovanillic acid and vanillylmandelic acid in human urine was developed based on capillary zone electrophoresis / amperometric detection with high sensitivity and good resolution.

  4. DNA typing by capillary electrophoresis

    Zhang, N.


    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  5. Copolymers For Capillary Gel Electrophoresis

    Liu, Changsheng; Li, Qingbo


    This invention relates to an electrophoresis separation medium having a gel matrix of at least one random, linear copolymer comprising a primary comonomer and at least one secondary comonomer, wherein the comonomers are randomly distributed along the copolymer chain. The primary comonomer is an acrylamide or an acrylamide derivative that provides the primary physical, chemical, and sieving properties of the gel matrix. The at least one secondary comonomer imparts an inherent physical, chemical, or sieving property to the copolymer chain. The primary and secondary comonomers are present in a ratio sufficient to induce desired properties that optimize electrophoresis performance. The invention also relates to a method of separating a mixture of biological molecules using this gel matrix, a method of preparing the novel electrophoresis separation medium, and a capillary tube filled with the electrophoresis separation medium.

  6. Biomedical applications of capillary electrophoresis

    Kartsova, L. A.; Bessonova, E. A.


    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references.

  7. Electrophoresis: The Basics (by D. M. Hawcroft)

    Voige, William H.


    D. M. Hawcroft. Oxford University Press: Oxford, 1997. 142 + xii pp. Index. ISBN 0-19-963563-3. $100.00. This concise monograph is one of a series on techniques in widespread use in biochemistry and cell and molecular biology. It seeks to present, in compact and readable form, the fundamentals of electrophoresis and does so very well. Both theory and practice are included, but emphasis is on the latter. Although the preface makes it clear that this book is intended for biologists, it also deserves a place in a truly complete chemistry library. The book is logically organized. Each of the nine chapters corresponds to either a step in an electrophoresis experiment (e.g., Chapter 7: Visualization of Separated Materials) or a major application (Chapter 4: The Electrophoresis of Native and Denatured Proteins). It is written as though the reader is getting ready to begin doing electrophoresis for the first time and needs a survey of the technique and its applications. A question that occurred to me repeatedly as I read through the book is: Exactly how did the author intend it to be used? One can view the book as either a text or a laboratory manual. As a resource that might be used as a supplementary text in a graduate or upper-division undergraduate course, it does an admirable job of presenting a thorough overview of modern electrophoresis. The figures and diagrams are exceptionally clear and present useful comparisons of results that can be obtained under a variety of conditions (e.g., the resolution of DNA fragments obtained with otherwise identical wedge and normal gels). Not all its explanations, however, are as cogent. It defines how the two portions of a discontinuous gel differ but fails to explain clearly how the porosity and pH differences result in the stacking effect, which is such a gel's primary advantage. Having it on hand as a laboratory manual would be much like having colleagues who are experts in all phases of electrophoresis to consult or to go to

  8. Synchrotron radiation for direct analysis of metalloproteins on electrophoresis gels.

    Ortega, Richard


    Metalloproteomics requires analytical techniques able to assess and quantify the inorganic species in metalloproteins. The most widely used methods are hyphenated techniques, based on the coupling of a high resolution chromatographic method with a high sensitivity method for metal analysis in solution. An alternative approach is the use of methods for solid sample analysis, combining metalloprotein separation by gel electrophoresis and direct analysis of the gels. Direct methods are based on beam analysis, such as lasers, ion beams or synchrotron radiation beams. The aim of this review article is to present the main features of synchrotron radiation based methods and their applications for metalloprotein analysis directly on electrophoresis gels. Synchrotron radiation X-ray fluorescence has been successfully employed for sensitive metal identification, and X-ray absorption spectroscopy for metal local structure speciation in proteins. Synchrotron based methods will be compared to ion beam and mass spectrometry for direct analysis of metalloproteins in electrophoresis gels.

  9. Comparison between a second generation automated multicapillary electrophoresis system with an automated agarose gel electrophoresis system for the detection of M-components.

    Larsson, Anders; Hansson, Lars-Olof


    During the last decade, capillary electrophoresis (CE) has emerged as an interesting alternative to traditional analysis of serum, plasma and urine proteins by agarose gel electrophoresis. Initially there was a considerable difference in resolution between the two methods but the quality of CE has improved significantly. We thus wanted to evaluate a second generation of automated multicapillary instruments (Capillarys, Sebia, Paris, France) and the high resolution (HR) buffer for serum or plasma protein analysis with an automated agarose gel electrophoresis system for the detection of M-components. The comparison between the two systems was performed with patients samples with and without M-components. The comparison included 76 serum samples with M-components > 1 g/L. There was a total agreement between the two methods for detection of these M-components. When studying samples containing oligoclonal bands/small M-components, there were differences between the two systems. The capillary electrophoresis system detected a slightly higher number of samples with oligoclonal bands but the two systems found oligoclonal bands in different samples. When looking at resolution, the agarose gel electrophoresis system yielded a slightly better resolution in the alpha and beta regions, but it required an experienced interpreter to be able to benefit from the increased resolution. The capillary electrophoresis has shorter turn-around times and bar-code reader that allows positive sample identification. The Capillarys in combination with HR buffer gives better resolution of the alpha and beta regions than the same instrument with the beta1-beta2+ buffer or the Paragon CZE2000 (Beckman) which was the first generation of capillary electrophoresis systems.

  10. Multidimensional capillary electrophoresis.

    Grochocki, Wojciech; Markuszewski, Michał J; Quirino, Joselito P


    Multidimensional separation where two or more orthogonal displacement mechanisms are combined is a promising approach to increase peak capacity in CE. The combinations allow dramatic improvement of analytical performance since the total peak capacity is given by a product of the peak capacities of all methods. The initial reports were concentrated on the construction of effective connections between capillaries for 2D analysis. Today, 2D and 3D CE systems are now able to separate real complex biological or environmental mixtures with good repeatability, improved resolution with minimal loss of sample. This review will present the developments in the field of multidimensional CE during the last 15 years. The endeavors in this specific field were on the development of interfaces, interface-free techniques including integrated separations, microdevices, and on-line sample concentration techniques to improve detection sensitivity.

  11. Electrophoresis as a management tool

    Morgan, R.P.; Chapman, J.A.; Noe, L.A.; Henny, C.J.


    The theme of this 1974 Northeast Fish and Wildlife Conference is 'A New Era'. Indeed, it is a new era for improved techniques to assist in management of our fish and wildlife resources for the maximum benefit of all. In some cases, the new techniques are primarily used in research.on fish and wildlife, and the results from the research are used to aid management and enforcement agencies in the decision-making process. One of the newer techniques that is being applied to problems in fisheries and wildlife is electrophoresis. In this paper, we review briefly the techniques of electrophoresis and illustrate research problems in wildlife and fisheries where the use of electrophoresis is now assisting or may potentially aid in management decisions.

  12. Optimized photonic crystal fibers supporting efficient capillary electrophoresis

    Calcerrada, M.; García-Ruiz, C.; Roy, P.; Gonzalez-Herraez, M.


    In this paper we present preliminary results on the use of Photonic Crystal Fibers (PCFs) in a conventional capillary electrophoresis system to separate and detect fluorescent species. PCFs show interesting advantages over conventional capillaries for this application, including larger surface-to-volume ratio and potential for higher resolution with comparable sensitivity. Our results illustrate some of these advantages, and we point out the need for stringent tolerances in the fabrication of specific PCFs for this application.

  13. Polyacrylamide gel electrophoresis of isoenzymes from Entamoeba species.

    Mathews, H M; Moss, D M; Healy, G R; Visvesvara, G S


    In this preliminary report, we describe a polyacrylamide gel electrophoresis technique for the resolution of isoenzyme patterns of four isolates of Entamoeba histolytica and one isolate of Entamoeba coli. Our findings were similar to previous findings for three enzyme systems: maleic enzyme (malate dehydrogenase [EC]), hexokinase (EC, and phosphoglucomutase (EC We found preliminary evidence that glucosephosphate isomerase (EC may also differentiate invasiv...

  14. Techniques For Focusing In Zone Electrophoresis

    Sharnez, Rizwan; Twitty, Garland E.; Sammons, David W.


    In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.

  15. Ratcheted electrophoresis of Brownian particles

    Kowalik, Mikołaj; Bishop, Kyle J. M.


    The realization of nanoscale machines requires efficient methods by which to rectify unbiased perturbations to perform useful functions in the presence of significant thermal noise. The performance of such Brownian motors often depends sensitively on their operating conditions—in particular, on the relative rates of diffusive and deterministic motions. In this letter, we present a type of Brownian motor that uses contact charge electrophoresis of a colloidal particle within a ratcheted channel to achieve directed transport or perform useful work against an applied load. We analyze the stochastic dynamics of this model ratchet to show that it functions under any operating condition—even in the limit of strong thermal noise and in contrast to existing ratchets. The theoretical results presented here suggest that ratcheted electrophoresis could provide a basis for electrochemically powered, nanoscale machines capable of transport and actuation of nanoscale components.

  16. Electrophoresis in strong electric fields.

    Barany, Sandor


    Two kinds of non-linear electrophoresis (ef) that can be detected in strong electric fields (several hundred V/cm) are considered. The first ("classical" non-linear ef) is due to the interaction of the outer field with field-induced ionic charges in the electric double layer (EDL) under conditions, when field-induced variations of electrolyte concentration remain to be small comparatively to its equilibrium value. According to the Shilov theory, the non-linear component of the electrophoretic velocity for dielectric particles is proportional to the cubic power of the applied field strength (cubic electrophoresis) and to the second power of the particles radius; it is independent of the zeta-potential but is determined by the surface conductivity of particles. The second one, the so-called "superfast electrophoresis" is connected with the interaction of a strong outer field with a secondary diffuse layer of counterions (space charge) that is induced outside the primary (classical) diffuse EDL by the external field itself because of concentration polarization. The Dukhin-Mishchuk theory of "superfast electrophoresis" predicts quadratic dependence of the electrophoretic velocity of unipolar (ionically or electronically) conducting particles on the external field gradient and linear dependence on the particle's size in strong electric fields. These are in sharp contrast to the laws of classical electrophoresis (no dependence of V(ef) on the particle's size and linear dependence on the electric field gradient). A new method to measure the ef velocity of particles in strong electric fields is developed that is based on separation of the effects of sedimentation and electrophoresis using videoimaging and a new flowcell and use of short electric pulses. To test the "classical" non-linear electrophoresis, we have measured the ef velocity of non-conducting polystyrene, aluminium-oxide and (semiconductor) graphite particles as well as Saccharomice cerevisiae yeast cells as a

  17. Chiral Separation by Capillary Zone Electrophoresis Used Cyclodextrins and Their Derivatives as Chiral Selector


    @@ Capillary zone electrophoresis (CZE) is a very pronising analytical technique for the optical isomer resolution of the compounds studied. The drawbacks of the techniques such as HPLC [1] were sophisticated stationary phases and/or the relatively high quantity of the chiral agent in the mobile phase, which do not exist in CZE. The capillary electrophoresis (CE) method can offer advantages on lower consumption of analyte and background electrolyte (BGE), shorter analysis time, and higher efficiencies [2-3

  18. A method for easily customizable gradient gel electrophoresis.

    Miller, Andrew J; Roman, Brandon; Norstrom, Eric


    Gradient polyacrylamide gel electrophoresis is a powerful tool for the resolution of polypeptides by relative mobility. Here, we present a simplified method for generating polyacrylamide gradient gels for routine analysis without the need for specialized mixing equipment. The method allows for easily customizable gradients which can be optimized for specific polypeptide resolution requirements. Moreover, the method eliminates the possibility of buffer cross contamination in mixing equipment, and the time and resources saved with this method in place of traditional gradient mixing, or the purchase of pre-cast gels, are noteworthy given the frequency with which many labs use gradient gel SDS-PAGE. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Enantiomeric Separation of Meptazinol Hydrochloride by Capillary Electrophoresis

    YUYun-qiu; CHENYan; LINi; QIUZhui-bai


    Aim To establish a capillary electrophoresis method for enantiomerie separation of meptazinol hydrochloride. Methods The separation conditions such as cyclodextrin(CD)type, buffer pH, concentration of 2,3,6-O-triInethyl-β-cyclodextrin and organic additives were optimized. An optimum concentration was 30 mmol·L-1 phosphate (pH 7.02)with 10% (W/V) TM-β-CD and 2% acetonitrile. Results Basehne resolution of the enantiomer was readily achieved using 2,3,6-O-trimethyl-β-cyclodextrin. Conclusion This is a convenient method for fast enantiomeric resolution of meptazinol hydrochloride.

  20. Capillary electrophoresis in food authenticity.

    Kvasnicka, Frantisek


    Food authenticity is a term which simply refers to whether the food purchased by the consumer matches its description. False description can occur in many forms, from the undeclared addition of water or other cheaper materials, or the wrong declaration of the amount of a particular ingredient in the product, to making false statements about the source of ingredients i.e., their geographic, plant, or animal origin. The aim of this review is to summarize applications of capillary electrophoresis in food authentication.

  1. Capillary electrophoresis systems and methods

    Dorairaj, Rathissh; Keynton, Robert S.; Roussel, Thomas J.; Crain, Mark M.; Jackson, Douglas J.; Walsh, Kevin M.; Naber, John F.; Baldwin, Richard P.; Franco, Danielle B.


    An embodiment of the invention is directed to a capillary electrophoresis apparatus comprising a plurality of separation micro-channels. A sample loading channel communicates with each of the plurality of separation channels. A driver circuit comprising a plurality of electrodes is configured to induce an electric field across each of the plurality of separation channels sufficient to cause analytes in the samples to migrate along each of the channels. The system further comprises a plurality of detectors configured to detect the analytes.

  2. Capillary Electrophoresis - Optical Detection Systems

    Sepaniak, M. J.


    Molecular recognition systems are developed via molecular modeling and synthesis to enhance separation performance in capillary electrophoresis and optical detection methods for capillary electrophoresis. The underpinning theme of our work is the rational design and development of molecular recognition systems in chemical separations and analysis. There have been, however, some subtle and exciting shifts in our research paradigm during this period. Specifically, we have moved from mostly separations research to a good balance between separations and spectroscopic detection for separations. This shift is based on our perception that the pressing research challenges and needs in capillary electrophoresis and electrokinetic chromatography relate to the persistent detection and flow rate reproducibility limitations of these techniques (see page 1 of the accompanying Renewal Application for further discussion). In most of our work molecular recognition reagents are employed to provide selectivity and enhance performance. Also, an emerging trend is the use of these reagents with specially-prepared nano-scale materials. Although not part of our DOE BES-supported work, the modeling and synthesis of new receptors has indirectly supported the development of novel microcantilevers-based MEMS for the sensing of vapor and liquid phase analytes. This fortuitous overlap is briefly covered in this report. Several of the more significant publications that have resulted from our work are appended. To facilitate brevity we refer to these publications liberally in this progress report. Reference is also made to very recent work in the Background and Preliminary Studies Section of the Renewal Application.

  3. Procedures for two-dimensional electrophoresis of proteins

    Tollaksen, S.L.; Giometti, C.S.


    High-resolution two-dimensional gel electrophoresis (2DE) of proteins, using isoelectric focusing in the first dimension and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) in the second, was first described in 1975. In the 20 years since those publications, numerous modifications of the original method have evolved. The ISO-DALT system of 2DE is a high-throughput approach that has stood the test of time. The problem of casting many isoelectric focusing gels and SDS-PAGE slab gels (up to 20) in a reproducible manner has been solved by the use of the techniques and equipment described in this manual. The ISO-DALT system of two-dimensional gel electrophoresis originated in the late 1970s and has been modified many times to improve its high-resolution, high-throughput capabilities. This report provides the detailed procedures used with the current ISO-DALT system to prepare, run, stain, and photograph two-dimensional gels for protein analysis.

  4. Capillary electrophoresis theory and practice

    Grossman, Paul D


    This book is designed to be a practical guide, used by wide audience, including those new to CE, those more experienced, routine users, those interested in technology development, and those involved with applications research. References have been emphasized to allow the reader to explore the detailed specifics and theoretical foundations.This book draws together the rapidly evolving, diverse, and multidisciplinary subject of capillary electrophoresis (CE). It is designed as a practical guide to be used by a wide audience, including those new to CE as well as more experienced users. T

  5. Electromigration dispersion in Capillary Electrophoresis

    Chen, Zhen; 10.1007/s11538-011-9708-7


    In a previous paper (S. Ghosal and Z. Chen Bull. Math. Biol. 2010, vol. 72, pg. 2047) it was shown that the evolution of the solute concentration in capillary electrophoresis is described by a nonlinear wave equation that reduced to Burger's equation if the nonlinearity was weak. It was assumed that only strong electrolytes (fully dissociated) were present. In the present paper it is shown that the same governing equation also describes the situation where the electrolytic buffer consists of a single weak acid (or base). A simple approximate formula is derived for the dimensionless peak variance which is shown to agree well with published experimental data.

  6. Organically modified sols as pseudostationary phases for microchip electrophoresis.

    Pumera, Martin; Wang, Joseph; Grushka, Eli; Lev, Ovadia


    We demonstrate that the selectivity of microchip electrophoresis separations is greatly improved by the presence of organically modified silica (Ormosil) sols in the run buffer. A negatively-charged N-(trimethoxysilylpropyl)ethylenediamine triacetic-acid (TETT)-based sol is used for improving the selectivity between nitroaromatic explosives and a methyltrimethoxysilane (MTMOS)-based sol is employed for enhancing the microchip separation of environmental pollutants, aminophenols. These sols are added to the run buffer and act as pseudostationary phases. Their presence in the run buffer changes the apparent mobility of studied solutes, and leads to a higher resolution. The observed mobilities changes reflect the interactions between the Ormosil sols and the solutes. Relevant experimental variables have been characterized and optimized. The diverse chemistry of Ormosil sols should be extremely useful for tailoring the selectivity of a wide range of electrophoresis microchip separations.

  7. DNA Sequencing Using capillary Electrophoresis

    Dr. Barry Karger


    The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other

  8. Conducting polymer electrodes for gel electrophoresis.

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D


    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  9. Conducting polymer electrodes for gel electrophoresis.

    Katarina Bengtsson

    Full Text Available In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene (PEDOT can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  10. Spontaneous chiral resolution in two-dimensional systems of patchy particles

    Martínez-González, J. A.; Chapela, G. A. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 México D.F. (Mexico); Quintana-H, J., E-mail: [Instituto de Química, Universidad Nacional Autónoma de México - Apdo. Postal 70213, 04510 Coyoacán, México D.F. (Mexico)


    Short ranged potentials and their anisotropy produce spontaneous chiral resolution in a two dimensional model of patchy particles introduced in this paper. This model could represent an equimolar binary mixture (racemic mixture) of two kinds of chiral molecules (enantiomers) adsorbed to a bi-dimensional domain where only lateral short ranged interactions are present. Most racemic mixtures undergo chiral resolution due to their spatial anisotropy, the combined effect of long range forces and the thermodynamic conditions. The patchy particles are modeled as a hard disk and four different bonding sites located to produce chirality. Phase behavior and structural properties are analysed using Discontinuous Molecular Dynamics in the canonical ensemble. When the four patchy particles are separated by the angles (60°, 120°, 60°, 120°), spontaneous chiral resolution is produced, given by the formation of homochiral clusters, if started from the corresponding racemic mixture. Gel behavior is also obtained in all the systems for low temperatures and low densities.

  11. Non-Aqueous Capillary Electrophoresis

    Szumski, Michał; Buszewski, Bogusław

    Non-aqueous capillary electrophoresis and capillary electrochromatography are special variants of these techniques. Here, organic solvents or their mixtures with or without dissolved electrolytes are used as separation buffer or mobile phase, respectively. The most important features of non-aqueous systems are: better solubility of more hydrophobic ionic substances (many natural products) than in water, much less current and Joule heating allows for using highly concentrated buffers and/or larger capillary internal diameters, polar interactions are enhanced in organic solvents which is often highly advantageous in chiral separation systems. This chapter presents most frequently used solvents, their properties, as well as shows pH* scale which is often used in non-aqueous systems.

  12. Electrophoresis-mass spectrometry probe

    Andresen, Brian D.; Fought, Eric R.


    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface.

  13. Supramolecular gel electrophoresis of large DNA fragments.

    Tazawa, Shohei; Kobayashi, Kazuhiro; Oyoshi, Takanori; Yamanaka, Masamichi


    Pulsed-field gel electrophoresis is a frequent technique used to separate exceptionally large DNA fragments. In a typical continuous field electrophoresis, it is challenging to separate DNA fragments larger than 20 kbp because they migrate at a comparable rate. To overcome this challenge, it is necessary to develop a novel matrix for the electrophoresis. Here, we describe the electrophoresis of large DNA fragments up to 166 kbp using a supramolecular gel matrix and a typical continuous field electrophoresis system. C3 -symmetric tris-urea self-assembled into a supramolecular hydrogel in tris-boric acid-EDTA buffer, a typical buffer for DNA electrophoresis, and the supramolecular hydrogel was used as a matrix for electrophoresis to separate large DNA fragments. Three types of DNA marker, the λ-Hind III digest (2 to 23 kbp), Lambda DNA-Mono Cut Mix (10 to 49 kbp), and Marker 7 GT (10 to 165 kbp), were analyzed in this study. Large DNA fragments of greater than 100 kbp showed distinct mobility using a typical continuous field electrophoresis system. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The Cutting Edge of Affinity Electrophoresis Technology

    Eiji Kinoshita


    Full Text Available Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years.

  15. The Cutting Edge of Affinity Electrophoresis Technology

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru


    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years.

  16. Compensating for Electro-Osmosis in Electrophoresis

    Rhodes, Percy H.; Snyder, Robert S.


    Simple mechanical adjustment eliminates transverse velocity component. New apparatus for moving-wall electrophoresis increases degree of collimation of chemical species in sample stream. Electrophoresis chamber set at slight angle in horizontal plane to adjust angle between solution flow and wall motion. Component of velocity created cancels electro-osmotic effect.

  17. Comparative Skeletal Muscle Proteomics Using Two-Dimensional Gel Electrophoresis.

    Murphy, Sandra; Dowling, Paul; Ohlendieck, Kay


    The pioneering work by Patrick H. O'Farrell established two-dimensional gel electrophoresis as one of the most important high-resolution protein separation techniques of modern biochemistry (Journal of Biological Chemistry1975, 250, 4007-4021). The application of two-dimensional gel electrophoresis has played a key role in the systematic identification and detailed characterization of the protein constituents of skeletal muscles. Protein changes during myogenesis, muscle maturation, fibre type specification, physiological muscle adaptations and natural muscle aging were studied in depth by the original O'Farrell method or slightly modified gel electrophoretic techniques. Over the last 40 years, the combined usage of isoelectric focusing in the first dimension and sodium dodecyl sulfate polyacrylamide slab gel electrophoresis in the second dimension has been successfully employed in several hundred published studies on gel-based skeletal muscle biochemistry. This review focuses on normal and physiologically challenged skeletal muscle tissues and outlines key findings from mass spectrometry-based muscle proteomics, which was instrumental in the identification of several thousand individual protein isoforms following gel electrophoretic separation. These muscle-associated protein species belong to the diverse group of regulatory and contractile proteins of the acto-myosin apparatus that forms the sarcomere, cytoskeletal proteins, metabolic enzymes and transporters, signaling proteins, ion-handling proteins, molecular chaperones and extracellular matrix proteins.

  18. Comparative Skeletal Muscle Proteomics Using Two-Dimensional Gel Electrophoresis

    Sandra Murphy


    Full Text Available The pioneering work by Patrick H. O’Farrell established two-dimensional gel electrophoresis as one of the most important high-resolution protein separation techniques of modern biochemistry (Journal of Biological Chemistry 1975, 250, 4007–4021. The application of two-dimensional gel electrophoresis has played a key role in the systematic identification and detailed characterization of the protein constituents of skeletal muscles. Protein changes during myogenesis, muscle maturation, fibre type specification, physiological muscle adaptations and natural muscle aging were studied in depth by the original O’Farrell method or slightly modified gel electrophoretic techniques. Over the last 40 years, the combined usage of isoelectric focusing in the first dimension and sodium dodecyl sulfate polyacrylamide slab gel electrophoresis in the second dimension has been successfully employed in several hundred published studies on gel-based skeletal muscle biochemistry. This review focuses on normal and physiologically challenged skeletal muscle tissues and outlines key findings from mass spectrometry-based muscle proteomics, which was instrumental in the identification of several thousand individual protein isoforms following gel electrophoretic separation. These muscle-associated protein species belong to the diverse group of regulatory and contractile proteins of the acto-myosin apparatus that forms the sarcomere, cytoskeletal proteins, metabolic enzymes and transporters, signaling proteins, ion-handling proteins, molecular chaperones and extracellular matrix proteins.


    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.


    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  20. DNA Sequencing Using capillary Electrophoresis

    Dr. Barry Karger


    The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other

  1. Capillary electrophoresis with laser-induced fluorescence detection for fast and reliable apolipoprotein E genotyping

    Somsen, GW; Welten, HTME; Mulder, FP; Swart, CW; Kema, IP; de Jong, GJ


    The use of capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection for the rapid determination of apolipoprotein E (apoE) genotypes was studied. High resolution and sensitive detection of the concerned DNA restriction fragments was achieved using CE buffers with hydroxypropylm

  2. Comparison of non-electrophoresis grade with electrophoresis grade BIS in NIPAM polymer gel preparation.

    Khodadadi, Roghayeh; Khajeali, Azim; Farajollahi, Ali Reza; Hajalioghli, Parisa; Raeisi, Noorallah


    The main objective of this study was to investigate the possibility of replacing electrophoresis cross-linker with non-electrophoresis N, N'-methylenebisacrylamide (BIS) in N-isopropyl acrylamide (NIPAM) polymer gel and its possible effect on dose response. NIPAM polymer gel was prepared from non-electrophoresis grade BIS and the relaxation rate (R2) was measured by MR imaging after exposing the gel to gamma radiation from Co-60 source. To compare the response of this gel with the one that contains electrophoresis grade BIS, two sets of NIPAM gel were prepared using electrophoresis and non-electrophoresis BIS and irradiated to different gamma doses. It was found that the dose-response of NIPAM gel made from the non-electrophoresis grade BIS is coincident with that of electrophoresis grade BIS. Taken all, it can be concluded that the non-electrophoresis grade BIS not only is a suitable alternative for the electrophoresis grade BIS but also reduces the cost of gel due to its lower price.

  3. Electrophoresis of diffuse soft particles.

    Duval, Jérôme F L; Ohshima, Hiroyuki


    A theory is presented for the electrophoresis of diffuse soft particles in a steady dc electric field. The particles investigated consist of an uncharged impenetrable core and a charged diffuse polyelectrolytic shell, which is to some extent permeable to ions and solvent molecules. The diffuse character of the shell is defined by a gradual distribution of the density of polymer segments in the interspatial region separating the core from the bulk electrolyte solution. The hydrodynamic impact of the polymer chains on the electrophoretic motion of the particle is accounted for by a distribution of Stokes resistance centers. The numerical treatment of the electrostatics includes the possibility of partial dissociation of the hydrodynamically immobile ionogenic groups distributed throughout the shell as well as specific interaction between those sites with ions from the background electrolyte other than charge-determining ions. Electrophoretic mobilities are computed on the basis of an original numerical scheme allowing rigorous evaluation of the governing transport and electrostatic equations derived following the strategy reported by Ohshima, albeit within the restricted context of a discontinuous chain distribution. Attention is particularly paid to the influence of the type of distribution adopted on the electrophoretic mobility of the particle as a function of its size, charge, degree of permeability, and solution composition. The results are systematically compared with those obtained with a discontinuous representation of the interface. The theory constitutes a basis for interpreting electrophoretic mobilities of heterogeneous systems such as environmental or biological colloids or swollen/deswollen microgel particles.

  4. Atomic Force Controlled Capillary Electrophoresis

    Lewis, Aaron; Yeshua, Talia; Palchan, Mila; Lovsky, Yulia; Taha, Hesham


    Lithography based on scanning probe microscopic techniques has considerable potential for accurate & localized deposition of material on the nanometer scale. Controlled deposition of metallic features with high purity and spatial accuracy is of great interest for circuit edit applications in the semiconductor industry, for plasmonics & nanophotonics and for basic research in surface enhanced Raman scattering & nanobiophysics. Within the context of metal deposition we will review the development of fountain pen nanochemistry and its most recent emulation Atomic Force Controlled Capillary Electrophoresis (ACCE). Using this latter development we will demonstrate achievement of unprecedented control of nanoparticle deposition using a three-electrode geometry. Three electrodes are attached: one on the outside of a metal coated glass probe, one on the inside of a hollow probe in a solution containing Au nanoparticles in the capillary, and a third on the surface where the writing takes place. The three electrodes provide electrical pulses for accurate control of deposition and retraction of the liquid from the surface overcoming the lack of control seen in both dip pen lithography & fountain pen nanochemistry when the tip contacts the surface. With this development, we demonstrate depositing a single 1.3 nm Au nanoparticle onto surfaces such as semiconductors.

  5. The Optimization of Electrophoresis on a Glass Microfluidic Chip and its Application in Forensic Science.

    Han, Jun P; Sun, Jing; Wang, Le; Liu, Peng; Zhuang, Bin; Zhao, Lei; Liu, Yao; Li, Cai X


    Microfluidic chips offer significant speed, cost, and sensitivity advantages, but numerous parameters must be optimized to provide microchip electrophoresis detection. Experiments were conducted to study the factors, including sieving matrices (the concentration and type), surface modification, analysis temperature, and electric field strengths, which all impact the effectiveness of microchip electrophoresis detection of DNA samples. Our results showed that the best resolution for ssDNA was observed using 4.5% w/v (7 M urea) lab-fabricated LPA gel, dynamic wall coating of the microchannel, electrophoresis temperatures between 55 and 60°C, and electrical fields between 350 and 450 V/cm on the microchip-based capillary electrophoresis (μCE) system. One base-pair resolution could be achieved in the 19-cm-length microchannel. Furthermore, both 9947A standard genomic DNA and DNA extracted from blood spots were demonstrated to be successfully separated with well-resolved DNA peaks in 8 min. Therefore, the microchip electrophoresis system demonstrated good potential for rapid forensic DNA analysis. © 2017 American Academy of Forensic Sciences.

  6. Optimizing Human Bile Preparation for Two-Dimensional Gel Electrophoresis

    Hao-Tsai Cheng


    Full Text Available Aims. Bile is an important body fluid which assists in the digestion of fat and excretion of endogenous and exogenous compounds. In the present study, an improved sample preparation for human bile was established. Methods and Material. The method involved acetone precipitation followed by protein extraction using commercially available 2D Clean-Up kit. The effectiveness was evaluated by 2-dimensional electrophoresis (2DE profiling quality, including number of protein spots and spot distribution. Results. The total protein of bile fluid in benign biliary disorders was 0.797 ± 0.465 μg/μL. The sample preparation method using acetone precipitation first followed by 2D Clean-Up kit protein extraction resulted in better quality of 2DE gel images in terms of resolution as compared with other sample preparation methods. Using this protocol, we obtained approximately 558 protein spots on the gel images and with better protein spots presentation of haptoglobin, serum albumin, serotransferrin, and transthyretin. Conclusions. Protein samples of bile prepared using acetone precipitation followed by 2D Clean-Up kit exhibited high protein resolution and significant protein profile. This optimized protein preparation protocol can effectively concentrate bile proteins, remove abundant proteins and debris, and yield clear presentation of nonabundant proteins and its isoforms on 2-dimensional electrophoresis gel images.

  7. Disposable polyester-toner electrophoresis microchips for DNA analysis.

    Duarte, Gabriela R M; Coltro, Wendell K T; Borba, Juliane C; Price, Carol W; Landers, James P; Carrilho, Emanuel


    Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.

  8. Chiral separation of metalaxyl by capillary zone electrophoresis using cyclodextrins.

    Santilio, Angela; D'Amato, Marilena; Cataldi, Lucilla; Sorbo, Angela; Dommarco, Roberto


    A simple and reliable analytical procedure using capillary electrophoresis with UV absorbance detection for the direct enantiomeric resolution and quantitation of chiral fungicide metalaxyl is described. Several native cyclodextrins and modified beta-cyclodextrins were investigated as chiral additives to 50 mM sodium tetraborate buffer pH 9.3. The effect of their concentration on the resolution of metalaxyl enantiomeric forms was studied. The best results were achieved when 55 mM succynyl-beta-cyclodextrin in 50 mM sodium tetraborate buffer pH 9.3 was used. The optimized method showed satisfactory intraday repeatability as far as relative migration times and relative peak areas are concerned, with a detection limit of 0.1 mM for both enantiomers, and has been successfully applied to the analysis of a real plant protection product containing metalaxyl-M (metalaxyl R-form) as active ingredient.

  9. [Disc electrophoresis of collagen protein (author's transl)].

    Reitmayr, P; Verzár, F


    The composition of proteins extracted from tendon collagen is investigated by disc electrophoresis. No qualitative differences can be demonstrated between young and old collagen. The action of formaldehyde and methionine on the tendons has no effect on the electrophoretic picture.

  10. Free-Flow Open-Chamber Electrophoresis

    Sharnez, Rizwan; Sammons, David W.


    Free-flow open-chamber electrophoresis variant of free-flow electrophoresis performed in chamber with open ends and in which velocity of electro-osmotic flow adjusted equal to and opposite mean electrophoretic velocity of sample. Particles having electrophoretic mobilities greater than mean mobility of sample particles move toward cathode, those with mobilities less move toward anode. Technique applied to separation of components of mixtures of biologically important substances. Sensitivity enhanced by use of tapered chamber.

  11. The latest advancements in proteomic two-dimensional gel electrophoresis analysis applied to biological samples.

    Santucci, Laura; Bruschi, Maurizio; Ghiggeri, Gian Marco; Candiano, Giovanni


    Two-dimensional gel electrophoresis (2DE) is one of the fundamental approaches in proteomics for the separation and visualization of complex protein mixtures. Proteins can be analyzed by 2DE using isoelectric focusing (IEF) in the first dimension, combined to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) in the second dimension, gel staining (silver and Coomassie), image analysis, and 2DE gel database. High-resolution 2DE can resolve up to 5,000 different proteins simultaneously (∼2,000 proteins routinely), and detect and quantify <1 ng of protein per spot. Here, we describe the latest developments for a more complete analysis of biological fluids.

  12. Chiral Separation by Capillary Zone Electrophoresis Used Cyclodextrins and Their Derivatives as Chiral Selector

    HOU; JingGuo


    Capillary zone electrophoresis (CZE) is a very pronising analytical technique for the optical isomer resolution of the compounds studied. The drawbacks of the techniques such as HPLC [1] were sophisticated stationary phases and/or the relatively high quantity of the chiral agent in the mobile phase, which do not exist in CZE. The capillary electrophoresis (CE) method can offer advantages on lower consumption of analyte and background electrolyte (BGE), shorter analysis time, and higher efficiencies [2-3]  ……

  13. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    Vrouwe, E.X.; Lüttge, Regina; Olthuis, Wouter; van den Berg, Albert

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  14. Evaluation of a multicapillary electrophoresis instrument for mitochondrial DNA typing.

    Stewart, John E B; Aagaard, Patricia J; Pokorak, Eric G; Polanskey, Deborah; Budowle, Bruce


    Laser-induced detection of fluorescent labeled PCR products and multi-wavelength detection (i.e., multicolor analysis) enables rapid generation of mtDNA sequencing profiles. Traditionally, polyacrylamide slab gels have been used as the electrophoretic medium for mtDNA sequencing in forensic analyses. Replacement of slab gel electrophoresis with capillary electrophoresis (CE) can facilitate automation of the analytical process. Automation and high throughput can be further enhanced by using multicapillary electrophoretic systems. The use of the ABI Prism 3100 Genetic Analyzer (ABI 3100, Applied Biosystems, Foster City, CA) as well as the ABI Prism 310 Genetic Analyzer (ABI 310, Applied Biosystems, Foster City, CA) were evaluated for mtDNA sequencing capabilities and compared with sequencing results obtained on the platform currently in use in the FBI Laboratory (the ABI Prism 377 DNA Sequencer, ABI 377, Applied Biosystems, Foster City, CA). Various studies were performed to assess the utility of the ABI 3100, as well as the ABI 310 for mtDNA sequencing. The tests included: comparisons of results obtained among the ABI 3100, the ABI 310 and the ABI 377 instruments; comparisons of results obtained within and between capillary arrays; evaluation of capillary length; evaluation of sample injection time; evaluation of the resolution of mixtures/heteroplasmic samples; and evaluation of the sensitivity of detection of a minor component with reduced template on the ABI 3100. In addition, other studies were performed to improve sample preparation; these included: comparison of template suppression reagent (TSR, Applied Biosystems, Foster City, CA) versus formamide; the use of Performa DTR Gel Filtration Cartridges (Edge BioSystems Inc., Gaithersburg, MD) versus Centri-Sep Spin Columns (Princeton Separations, Adelphia, NJ) for product purification after cycle sequencing; and sample stability after denaturation. The data support that valid and reliable results can be obtained

  15. Computer-supported detection of M-components and evaluation of immunoglobulins after capillary electrophoresis.

    Jonsson, M; Carlson, J; Jeppsson, J O; Simonsson, P


    Electrophoresis of serum samples allows detection of monoclonal gammopathies indicative of multiple myeloma, Waldenström macroglobulinemia, monoclonal gammopathy of undetermined significance, and amyloidosis. Present methods of high-resolution agarose gel electrophoresis (HRAGE) and immunofixation electrophoresis (IFE) are manual and labor-intensive. Capillary zone electrophoresis (CZE) allows rapid automated protein separation and produces digital absorbance data, appropriate as input for a computerized decision support system. Using the Beckman Paragon CZE 2000 instrument, we analyzed 711 routine clinical samples, including 95 monoclonal components (MCs) and 9 cases of Bence Jones myeloma, in both the CZE and HRAGE systems. Mathematical algorithms developed for the detection of monoclonal immunoglobulins (MCs) in the gamma- and ss-regions of the electropherogram were tested on the entire material. Additional algorithms evaluating oligoclonality and polyclonal concentrations of immunoglobulins were also tested. CZE electropherograms corresponded well with HRAGE. Only one IgG MC of 1 g/L, visible on HRAGE, was not visible after CZE. Algorithms detected 94 of 95 MCs (98.9%) and 100% of those visible after CZE. Of 607 samples lacking an MC on HRAGE, only 3 were identified by the algorithms (specificity, 99%). Algorithms evaluating total gammaglobulinemia and oligoclonality also identified several cases of Bence Jones myeloma. The use of capillary electrophoresis provides a modern, rapid, and cost-effective method of analyzing serum proteins. The additional option of computerized decision support, which provides rapid and standardized interpretations, should increase the clinical availability and usefulness of protein analyses in the future.

  16. A review on preparative and semi-preparative offgel electrophoresis for multidimensional protein/peptide assessment.

    Moreda-Piñeiro, Antonio; García-Otero, Natalia; Bermejo-Barrera, Pilar


    Mass spectrometry (MS) techniques are commonly used for protein identification and further analysis of selected protein spots after high resolution 2-D electrophoresis. Complementary gel-free approaches have been developed during the last few years and have shown to be useful tools in modern proteomics. The development and application of various gel-free electrophoresis devices for performing protein fractionation according to the pI differences is therefore a topic of interest. This review describes the current state of isoelectric focusing (IEF) gel-free electrophoresis based on the Agilent offgel 3100 fractionator. The review includes, therefore, (i) an overview on IEF as well as other previous IEF gel-free electrophoresis developments; (ii) offgel fundamentals and future trends; (iii) advantages and disadvantages of current offgel procedures; (iv) requirements of isolated protein pellets for further offgel fractionation; (v) offgel fraction requirements to perform the second dimensional analysis by advance electrophoresis and chromatographic techniques; and (vi) effect of the offgel operating conditions on the stability of metal-protein complexes.

  17. Tilted hexagonal post arrays: DNA electrophoresis in anisotropic media.

    Chen, Zhen; Dorfman, Kevin D


    Using Brownian dynamics simulations, we show that DNA electrophoresis in a hexagonal array of micron-sized posts changes qualitatively when the applied electric field vector is not coincident with the lattice vectors of the array. DNA electrophoresis in such "tilted" post arrays is superior to the standard "un-tilted" approach; while the time required to achieve a resolution of unity in a tilted post array is similar to an un-tilted array at a low-electric field strengths, this time (i) decreases exponentially with electric field strength in a tilted array and (ii) increases exponentially with electric field strength in an un-tilted array. Although the DNA dynamics in a post array are complicated, the electrophoretic mobility results indicate that the "free path," i.e. the average distance of ballistic trajectories of point-sized particles launched from random positions in the unit cell until they intersect the next post, is a useful proxy for the detailed DNA trajectories. The analysis of the free path reveals a fundamental connection between anisotropy of the medium and DNA transport therein that goes beyond simply improving the separation device.

  18. Matching Two-dimensional Gel Electrophoresis' Spots

    Dos Anjos, António; AL-Tam, Faroq; Shahbazkia, Hamid Reza


    This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches. This ar......This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches...

  19. Application of Microchip Electrophoresis for Clinical Tests

    Yatsushiro, Shouki; Kataoka, Masatoshi

    Microchip electrophoresis has recently attracted much attention in the field of nuclear acid analysis due to its high efficiency, ease of operation, low consumption of samples and reagents, and relatively low costs. In addition, the analysis has expanded to an analytical field like not only the analysis of DNA but also the analysis of RNA, the protein, the sugar chain, and the cellular function, etc. In this report, we showed that high-performance monitoring systems for human blood glucose levels and α-amylase activity in human plasma using microchip electrophoresis.

  20. Microfluidic chip-capillary electrophoresis devices

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng


    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences.The book gives an overview of the development of MC and CE technology as well as technology that now allows

  1. Micropreparative one- and two-dimensional electrophoresis: improvement with new photopolymerization systems.

    Rabilloud, T; Vincon, M; Garin, J


    To improve the efficiency of one- and two-dimensional electrophoresis for micropreparative purposes, the use of gels polymerized with other initiators than the standard N,N,N',N'-tetramethylethylenediamine (TEMED)/persulfate systems for sodium dodecyl sulfate electrophoresis has been investigated. We show here that the recently described photoinitiator system, composed of methylene blue, toluene sulfinate and diphenyliodonium chloride, leads to a decreased resolution. Resolution can be restored if methylene blue is replaced by riboflavin. Two-dimensional electrophoresis with mg loadings of proteins has also been evaluated with these systems. Independently of the polymerization system, resolution for the first dimension is low with rod gels, increases with gel strips and is further improved when immobilized pH gradients are used. Here too, only the riboflavin/sulfinate/iodonium system results in a resolution that matches the one obtained with the standard TEMED/persulfate system. Gels polymerized with the riboflavin/sulfinate/iodonium system yield better results upon N-terminal microsequencing after blotting than gels polymerized with the standard TEMED/persulfate system.

  2. Development in electrophoresis: instrumentation for two-dimensional gel electrophoresis of protein separation and application of capillary electrophoresis in micro-bioanalysis

    Xu, Aoshuang [Iowa State Univ., Ames, IA (United States)


    This dissertation begins with a general introduction of topics related to this work. The following chapters contain three scientific manuscripts, each presented in a separate chapter with accompanying tables, figures, and literature citations. The final chapter summarizes the work and provides some prospective on this work. This introduction starts with a brief treatment of the basic principles of electrophoresis separation, followed by a discussion of gel electrophoresis and particularly polyacrylamide gel electrophoresis for protein separation, a summary of common capillary electrophoresis separation modes, and a brief treatment of micro-bioanalysis application of capillary electrophoresis, and ends with an overview of protein conformation and dynamics.

  3. Graphitic carbon nitride embedded hydrogels for enhanced gel electrophoresis.

    Zarei, Mohammad; Ahmadzadeh, Hossein; Goharshadi, Elaheh K; Farzaneh, Ali


    Here, we show, for the first time, the use of graphitic carbon nitride (g-C3N4) nanosheets to improve the resolution and efficiency of protein separation in gel electrophoresis. By loading 0.04% (m/v) g-C3N4 nanosheets into the polyacrylamide gel at 25 °C, the thermal conductivity increased approximately 80% which resulted in 20% reduction in Joule heating and overall increase of separation efficiency. Also, polymerization of acrylamide occurred in the absence of tetramethylethylenediamine (TEMED) when the polyacrylamide gel contained g-C3N4 nanosheets. Hence, the g-C3N4 act simultaneously as a polymerization catalyst as well as heat sinks to lower Joule heating effect on band broadening.

  4. Separation of Aminobenzoic Acids by Gold Nanoparticle modified Capillary Electrophoresis

    YAN,Hongtao; LI,Tuo; GUO,Yanli


    A novel method for the separation of aminobenzoic acids by capillary electrophoresis was developed.The capillary was modified with gold nanoparticles.The effect of gold nanoparticles on the resolution and selectivity of separation was investigated.The influence of separation voltage,pH and buffer concentration on the separation of aminobenzoic acids was also examined.It was found that the presence of gold nanoparticles improved the precision of the analysis and increased the separation efficiency.Under the optimized experiment conditions,aminobenzoic acids were separated and determined.Linearity was established over the concentration range 0.5-40 μg·mL-1 with correlation coefficients of 0.9978-0.9992.The detection limits (S/N = 3) were from 0.1 to 0.5 μg·mL-1.

  5. Penicillin G as a novel chiral selector in capillary electrophoresis.

    Dixit, Shuchi; Park, Jung Hag


    The penicillin sub-class of β-lactam antibiotics has not been examined for its enantiodiscriminating abilities in capillary electrophoresis (CE) until date. The present work was therefore designed to evaluate penicillin G potassium salt (PenG) as an ion-pair chiral selector (CS) using CE for its several attributes, namely, high solubility in water and lower alcohols, structure allowing multiple interactions with analytes and cost-effectiveness. Systematic experiments were performed to investigate the effect of composition of background electrolyte, applied voltage and capillary temperature on chiral separation. Baseline resolutions of enantiomers of five basic chiral drugs (namely, darifenacin, citalopram, sertraline, propranolol and metoprolol) were attained using a background electrolyte composed of water:methanol (90:10, v/v) and consisting of 10.7 or 16.1mM CS at 20°C using an applied voltage of 5kV.

  6. Separation of cold medicine ingredients by capillary electrophoresis.

    Suntornsuk, L


    This study demonstrates the separation of cold medicine ingredients (e.g., phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol) by capillary zone electrophoresis and micellar electrokinetic chromatography. Factors affecting their separations were the buffer pH and the concentrations of buffer, surfactant and organic modifiers. Optimum results were obtained with a 10 mM sodium dihydrogen-phosphate-sodium tetraborate buffer containing 50 mM sodium dodecyl sulfate (SDS) and 5% methanol (MeOH), pH 9.0. The carrier electrolyte gave a baseline separation of phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol with a resolution of 1.2, and the total migration time was 11.38 min.

  7. Protein separation by continuous-flow electrophoresis in microgravity.

    Clifton, M J; Roux-de Balmann, H; Sanchez, V


    During the IML-2 space shuttle mission, the RAMSES instrument was operated in the Spacelab module. This continuous-flow electrophoresis device performs separation and purification of protein solutions on a preparative scale. Samples containing artificial mixtures of pure proteins were used to test the capabilities of the device, and useful separations were obtained for proteins having a mobility difference of only 3 x 10(-9) m2 V-1 s-1. Operating conditions that cannot be applied on earth were explored for two different sample concentrations, one of which is too high to allow treatment on earth. It agrees well with a previously published numerical model in that the main cause of loss in resolution in this process is the electrohydrodynamic spreading of the protein filaments.

  8. Zone electrophoresis in an inner-cooling wide-bore electrophoresis system with UV detection.

    Guo, Yugao; Liu, Danning; Wang, Huaifeng; Yuan, Ruijuan; Bao, James Jianmin


    A novel, high-performance wide-bore electrophoresis (WE) system with inner-cooling has been developed. By introducing the mode of a shell and tube heat exchanger into this system to remove Joule heat generated during electrophoresis, it is feasible to extend electrophoresis from the conventional capillary (i.d. tube (i.d. >1000 microm). The wide tube allows the loading of over 1.0 microL of the sample with an LOD of 3.0 x 10(-4) mg/mL (signal-to-noise ratio, 3:1). Satisfactory separations of model compounds have been achieved on the WE system.

  9. Modulation in capillary electrophoresis and analysis of DNA

    Demana, T.


    Analyte velocity modulation results when a sinusoidal AC voltage is superimposed onto the driving DC voltage. The principal motivation for the work has been exploration of voltage modulation as a technique is especially effective with excess noise limited detectors such as the refractive index detector. One advantage of an electrical modulation technique, over an optical one, is its applicability to all detection schemes. The mathematical theory of analyte velocity modulation is presented in this work. The main idea is that the superimposed AC field forces the electroosmotic flow profile to oscillate between laminar and plug flow at the modulation frequency. The changing profile induces a radial movement of sample species to and from the capillary surface. The induced sample concentration gradients can be monitored by carefully probing the capillary surface. The resulting signal is a derivative of the normal shaped peak. Derivative shaped peaks can be observed with cations, but not with anions. Anions are unable to approach the double layer region and therefore are unaffected by the modulation process. The results indicate that the double layer thickness in free solution capillary electrophoresis might be larger than the nominally calculated 3 nm. Analyte velocity modulation can be used as a variation of pulsed field electrophoresis in gel-filled capillaries. This technique provides superior resolution of DNA fragments and shortens their migration times. The authors demonstrate subpicogram detection limits for nucleic acids, with very high efficiencies. Theoretical plate numbers are in the range of 10[sup 5] to 10[sup 6]. They also demonstrate that sine wave modulation gives resolution similar to square wave modulation for frequencies between 10 and 100 Hz. Although a square wave contains high frequency harmonics, the authors show that in general its coupling to DNA motions is not always inferior to that of a sine wave.




    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNA populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.

  11. Concentration polarization in nanochannel DNA electrophoresis

    Dubsky, Pavel; Das, Siddhartha; Berg, van den Albert; Eijkel, Jan C.T.


    We demonstrate that the large field electrophoresis of a single DNA molecule in nanofluidic systems is accompanied by concentration polarization. We illustrate this phenomena by utilizing our electrophoretic simulation tool SIMUL. First we in-vestigate a simple system with univalent strong electroly

  12. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida;


    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  13. Establishment and Preliminary Application of Two dimensional Electrophoresis and Mass Spectrometry in Ovary Study

    Xiang MA; Ye-fei ZHU; Jia-hao SHA; Zuo-min ZHOU; Jia-yin LIU


    Objective To apply two-dimensional electrophoresis and mass spectrometry in the ovary proteome research Methods Protein extractions from mouse ovaries were run in IPGphor isoelectric focus system with 11 cm and 24 cm IPG strips respectively (pH 3~10, 0.3 mm thick), then the protein spots were identified by mass spectrometry.Results The ovary protein exactions separated by two-dimensional electrophoresis have got high resolution, and identifing protein by mass spectrometry was highly efficient and facilitly.These two techniques should facilitate further investigation of female reproduction proteome research.Conclusion These two rapid high resolutions and efficient techniques have a variety of applications foreground in female reproduction proteome pattern research.

  14. Should routine laboratories stop doing screening serum protein electrophoresis and replace it with screening immune-fixation electrophoresis? No quick fixes: Counterpoint.

    Smith, Joel D; Raines, Geoffrey; Schneider, Hans G


    Monoclonal gammopathies are characterised by the production of a monoclonal immunoglobulin or free light chains by an abnormal plasma cell or B-cell clone and may indicate malignancy or a precursor (MGUS). There is currently no consensus on the initial test or combination of tests to be performed in suspected monoclonal gammopathies but serum protein electrophoresis and urine protein electrophoresis are commonly requested as initial investigations. If abnormal, immunofixation electrophoresis is then performed to confirm the presence of paraprotein and to determine its heavy and light chain type. Recently, some groups have developed simplified "screening" IFE methods for use in parallel to SPEP for the detection monoclonal gammopathies. We argue here that screening IFE may be of benefit in clinical laboratories using SPEP with poor resolution in the β-region, assisting in the detection of mainly IgA paraprotein, but may be of less benefit in laboratories utilising higher resolution gels. Further it may increase the detection of trace bands of questionable clinical significance, representing transient phenomena in infectious and auto-immune conditions or very low risk MGUS. The increased detection of these bands using screening IFE would require further patient follow up, possibly causing unnecessary patient anxiety and additional follow up healthcare costs.

  15. Using Gel Electrophoresis To Illustrate Protein Diversity and Isoelectric Point.

    Browning, Mark; Vanable, Joseph


    Demonstrates the differences in protein structures by focusing on isoelectric point with an experiment that is observable under certain pH levels in gel electrophoresis. Explains the electrophoresis procedure and reports results of the experiments. (YDS)

  16. Chiral Separation of Ibuprofen and Terbutaline by Nonaqueous Capillary Electrophoresis with Conductance Detection


    In the nonaqueous N,N-dimethylformamide medium, the chiral drugs ibuprofen and terbutaline were successfully separated with sulfonyl-β-cyclodextrin(s-β-CD) as the chiral selector by capillary electrophoresis with conductance detection. The comparison of the effects of three CDS(β-CD, diethylic-β-CD, sulfonyl-β-CD) on the chiral separation was made and the resolution mechanism was proposed.

  17. Physical and genetic mapping of the genomes of five Mycoplasma hominis strains by pulsed-field gel electrophoresis

    Ladefoged, Søren; Christiansen, Gunna


    -field gel electrophoresis. All the ApaI, SmaI, BamHI, XhoI, and SalI restriction sites (total of 21 to 33 sites in each strain) were placed on the physical map, yielding an average resolution of 26 kb. The maps were constructed using three different approaches: (i) size determination of DNA fragments...

  18. Electrokinetics of nanoparticle gel-electrophoresis.

    Hill, Reghan J


    Gel-electrophoresis has been demonstrated in recent decades to successfully sort a great variety of nanoparticles according to their size, charge, surface chemistry, and corona architecture. However, quantitative theoretical interpetations have been limited by the number and complexity of factors that influence particle migration. Theoretical models have been fragmented and incomplete with respect to their counterparts for free-solution electrophoresis. This paper unifies electrokinetic models that address complex nanoparticle corona architectures, corona and gel charge regulation (e.g., by the local pH), multi-component electrolytes, and non-linear electrostatics and relaxation effects. By comprehensively addressing the electrokinetic aspects of the more general gel-electrophoresis problem, in which short-ranged steric interactions are significant, a stage is set to better focus on the physicochemical and steric factors. In this manner, it is envisioned that noparticle gel-electrophoresis may eventually be advanced from a nanoparticle-characterization tool to one that explicitly probes the short-ranged interactions of nanoparticles with soft networks, such as synthetic gels and biological tissues. In this paper, calculations are undertaken that identify a generalized Hückel limit for nanoparticles in low-conductivity gels, and a new Smoluchowski limit for polyelectrolyte-coated particles in high-conductivity gels that is independent of the gel permeability. Also of fundamental interest is a finite, albeit small, electrophoretic mobility for uncharged particles in charged gels. Electrophoretic mobilities and drag coefficients (with electroviscous effects) for nanoparticles bearing non-uniform coronas show that relaxation effects are typically weak for the small nanoparticles (radius ≈3-10 nm) to which gel-electrophoresis has customarily been applied, but are profound for the larger nanoparticles (radius ≳ 40 nm in low conductivity gels) to which passivated gel-electrophoresis

  19. Ketoprofen analysis in serum by capillary electrophoresis.

    Friedberg, M; Shihabi, Z K


    A method for the quantification of ketoprofen, a new non-prescription non-steroidal anti-inflammatory drug, in serum, by capillary zone electrophoresis for therapeutic monitoring and emergency toxicology is described. Serum is deproteinized with acetonitrile in the presence of an internal standard, to remove serum proteins and to induce sample stacking. The migration time was about 10 min. The assay was linear between 1-10 mg/l without any interferences. The method compared well to an HPLC assay. The HPLC afforded a better detection limit, but the CE was less expensive to operate. This method demonstrates that capillary electrophoresis is a simple and effective method for determination of ketoprofen as well as other drugs in human serum at levels close to 1 mg/l.

  20. Sampling techniques for single-cell electrophoresis.

    Cecala, Christine; Sweedler, Jonathan V


    Cells are extraordinarily complex, containing thousands of different analytes with concentrations spanning at least nine orders of magnitude. Analyzing single cells instead of tissue homogenates provides unique insights into cell-to-cell heterogeneity and aids in distinguishing normal cells from pathological ones. The high sensitivity and low sample consumption of capillary and on-chip electrophoresis, when integrated with fluorescence, electrochemical, and mass spectrometric detection methods, offer an ideal toolset for examining single cells and even subcellular organelles; however, the isolation and loading of such small samples into these devices is challenging. Recent advances have addressed this issue by interfacing a variety of enhanced mechanical, microfluidic, and optical sampling techniques to capillary and on-chip electrophoresis instruments for single-cell analyses.

  1. Fish Muscle Proteins: Extraction, Quantitation, and Electrophoresis

    Smith, Denise

    Electrophoresis can be used to separate and visualize proteins. In sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), proteins are separated based on size. When protein samples are applied to such gels, it is usually necessary to know the protein content of the sample. This makes it possible to apply a volume of sample to the gel such that samples have a comparable amount of total protein. While it is possible to use an official method of protein analysis (e.g., Kjeldahl, N combustion) for such an application, it often is convenient to use a rapid spectroscopic protein analysis that requires only a small amount of sample. The bicinchoninic acid (BCA) assay method will be used for this purpose.

  2. A New Conductivity Detector for Capillary Electrophoresis


    A new conductivity detector for capillary electrophoresis consisting of an electrochemical cell and a conductive meter was developed. In the cell, the microelectrode and capillary were inserted through the cell wall and fixed by screws and sealing ring, the ends of microelectrode and capillary were located by a guide with two cross holes. LOD for K+ was 1.5×10-5 mol/L.

  3. Method and apparatus for continuous electrophoresis

    Watson, Jack S.


    A method and apparatus for conducting continuous separation of substances by electrophoresis are disclosed. The process involves electrophoretic separation combined with couette flow in a thin volume defined by opposing surfaces. By alternating the polarity of the applied potential and producing reciprocating short rotations of at least one of the surfaces relative to the other, small increments of separation accumulate to cause substantial, useful segregation of electrophoretically separable components in a continuous flow system.

  4. Capillary Electrophoresis in the Presence of Fosfomycin


    Fosfomyein, a sodim salt of cis-(3-methyloxiranyl) phosphonic acid, was used as electrolyte in binary methanol-water media for capillary electrophoresis. The variety of electroosmotic flow with pH*,methanol concentration and ionic strength was investigated. The migration behavior of nine bases was examined under various conditions, and the separation of thymine, cytosine, 5-flurouracil, 4,6-diamino-pyrimidine, purine was accomplished.

  5. Stability of Blood Samples for Hemoglobin Electrophoresis

    Yadira Valdés Fraser


    Full Text Available Background: the National Medical Genetics Center has conducted the prenatal screening for hemoglobinopathies in the province of Artemisa and the quality control of this program nationwide; reliability of the results is determined by the quality of the samples used. Objective: to describe the stability of whole blood samples using EDTAK2 and heparin as anticoagulants. Methods: a descriptive study of 100 samples of whole blood from pregnant women and their husbands was conducted at the National Medical Genetics Center. Hemoglobin electrophoresis with Hydrasis technology was performed using 10 % EDTAK2, 2.2 % and 5 % heparin, temperature at 4-8 0C and shelf-life of 7.15 and 30 days. Results: samples with EDTAK2 showed stability for a month with accuracy and repeatability in the electrophoresis runs. By using 5 % and 2.2 % heparin, problems were found in all periods analyzed. Conclusions: 10 % EDTAK2 anticoagulant is appropriate to ensure the reliability of the results in the screening for hemoglobinopathies. The results obtained in this study can be applied in all clinical, hematological and hemoglobin electrophoresis laboratories.

  6. Comparative Two-Dimensional Fluorescence Gel Electrophoresis.

    Ackermann, Doreen; König, Simone


    Two-dimensional comparative fluorescence gel electrophoresis (CoFGE) uses an internal standard to increase the reproducibility of coordinate assignment for protein spots visualized on 2D polyacrylamide gels. This is particularly important for samples, which need to be compared without the availability of replicates and thus cannot be studied using differential gel electrophoresis (DIGE). CoFGE corrects for gel-to-gel variability by co-running with the sample proteome a standardized marker grid of 80-100 nodes, which is formed by a set of purified proteins. Differentiation of reference and analyte is possible by the use of two fluorescent dyes. Variations in the y-dimension (molecular weight) are corrected by the marker grid. For the optional control of the x-dimension (pI), azo dyes can be used. Experiments are possible in both vertical and horizontal (h) electrophoresis devices, but hCoFGE is much easier to perform. For data analysis, commercial software capable of warping can be adapted.

  7. Resolving Acetylated and Phosphorylated Proteins by Neutral Urea Triton-Polyacrylamide Gel Electrophoresis, NUT-PAGE

    Buehl, Christopher J.; Deng, Xiexiong; Liu, Mengyu; Hovde, Stacy; Xu, Xinjing; Kuo, Min-Hao


    Protein acetylation and phosphorylation can be key modifications that regulate both normal and pathological protein functions. Current gel systems used to analyze modified proteins require either expensive reagents or time–consuming second dimension electrophoresis. In this manuscript, we present a neutral pH gel system that allows the analysis of acetylated and phosphorylated proteins. This neutral pH urea Triton-polyacrylamide gel electrophoresis system, or NUT-PAGE, separates proteins based on their charge at pH 7 and generates discrete bands from each acetylated and phosphorylated species. In addition, the gel is composed of common and inexpensive laboratory reagents, and requires only a single dimension of electrophoresis. We are able to demonstrate the effectiveness of this system by analyzing phosphorylated species of an acidic protein, α-synuclein, and both acetylated and phosphorylated species of a basic protein, histone H3. NUT-PAGE thus provides a cost-effective alternative to resolving acetylated and phosphorylated proteins, and potentially proteins with other post-translational modifications that alter net charge. Method Summary Here we present a single-dimension neutral pH urea Triton-polyacrylamide gel electrophoresis (NUT-PAGE) system affording high-resolution separation of acetylated and phosphorylated proteins. PMID:25109292

  8. Trapping and breaking of in vivo nicked DNA during pulsed-field gel electrophoresis

    Khan, Sharik R.; Kuzminov, Andrei


    Pulsed field gel electrophoresis (PFGE) offers a high-resolution approach to quantify chromosomal fragmentation in bacteria, measured as percent of chromosomal DNA entering the gel. The degree of separation in PFG depends upon the size of DNA, as well as various conditions of electrophoresis, such as electric field strength (FS), time of electrophoresis, switch time and buffer composition. Here we describe a new parameter, the structural integrity of the sample DNA itself, that influences its migration through PFGs. We show that sub-chromosomal fragments containing both spontaneous and DNA damage-induced nicks are prone to breakage during PFGE. Such breakage at single strand interruptions results in artefactual decrease in molecular weight of linear DNA making accurate determination of the number of double strand breaks difficult. While breakage of nicked sub-chromosomal fragments is FS-independent, some high molecular weight sub-chromosomal fragments are also trapped within wells under the standard PFGE conditions. This trapping can be minimized by lowering the field strength and increasing the time of electrophoresis. We discuss how breakage of nicked DNA may be mechanistically linked to trapping. Our results suggest how to optimize conditions for PFGE when quantifying chromosomal fragmentation induced by DNA damage. PMID:23770235

  9. Trapping and breaking of in vivo nicked DNA during pulsed field gel electrophoresis.

    Khan, Sharik R; Kuzminov, Andrei


    Pulsed field gel electrophoresis (PFGE) offers a high-resolution approach to quantify chromosomal fragmentation in bacteria, measured as percentage of chromosomal DNA entering the gel. The degree of separation in pulsed field gel (PFG) depends on the size of DNA as well as various conditions of electrophoresis such as electric field strength, time of electrophoresis, switch time, and buffer composition. Here we describe a new parameter, the structural integrity of the sample DNA itself, that influences its migration through PFGs. We show that subchromosomal fragments containing both spontaneous and DNA damage-induced nicks are prone to breakage during PFGE. Such breakage at single-strand interruptions results in artifactual decrease in molecular weight of linear DNA making accurate determination of the number of double-strand breaks difficult. Although breakage of nicked subchromosomal fragments is field strength independent, some high-molecular-weight subchromosomal fragments are also trapped within wells under the standard PFGE conditions. This trapping can be minimized by lowering the field strength and increasing the time of electrophoresis. We discuss how breakage of nicked DNA may be mechanistically linked to trapping. Our results suggest how to optimize conditions for PFGE when quantifying chromosomal fragmentation induced by DNA damage. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Disposable pen-shaped capillary gel electrophoresis cartridge for fluorescence detection of bio-molecules

    Amirkhanian, Varoujan; Tsai, Shou-Kuan


    We introduce a novel and cost-effective capillary gel electrophoresis (CGE) system utilizing disposable pen-shaped gelcartridges for highly efficient, high speed, high throughput fluorescence detection of bio-molecules. The CGE system has been integrated with dual excitation and emission optical-fibers with micro-ball end design for fluorescence detection of bio-molecules separated and detected in a disposable pen-shaped capillary gel electrophoresis cartridge. The high-performance capillary gel electrophoresis (CGE) analyzer has been optimized for glycoprotein analysis type applications. Using commercially available labeling agent such as ANTS (8-aminonapthalene-1,3,6- trisulfonate) as an indicator, the capillary gel electrophoresis-based glycan analyzer provides high detection sensitivity and high resolving power in 2-5 minutes of separations. The system can hold total of 96 samples, which can be automatically analyzed within 4-5 hours. This affordable fiber optic based fluorescence detection system provides fast run times (4 minutes vs. 20 minutes with other CE systems), provides improved peak resolution, good linear dynamic range and reproducible migration times, that can be used in laboratories for high speed glycan (N-glycan) profiling applications. The CGE-based glycan analyzer will significantly increase the pace at which glycoprotein research is performed in the labs, saving hours of preparation time and assuring accurate, consistent and economical results.

  11. Restriction Enzyme Pattern Analysis of Mycobacteria DNA by Capillary Electrophoresis with Laser-induced Fluorescence Detection

    Li Yuanqian; Wang Guoqing; Mi Jianping; Zhou Ying; Zeng Hongyan; Zhang Chaowu


    A new method for rapidly detecting restriction enzyme patterns of Mycobacterium DNA using capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD)was developed.Polymerase chain reaction was used to amplify a 439-bp fragment of a 65,000-kDa(Mr)heat shock protein gene(hsp65)of Mycobacterium.After digesting amplification products by BstEII and HaeIII,patterns of enzyme cleavage products were detected by both CE-LIFD and agarose gel electrophoresis(AGE),respectively.Experimental parameters of CE were optimized.Restriction enzyme patterns of Mycobacterium DNA were detected in optimum electrophoresis conditions:a coated capillary column with a length of 50 cm and an internal diameter of 100 μm,an electrophoresis buffer of 45 mmol/1 Tris-boric acid-ethylenediaminetetraacetic acid,and a running voltage of 11 kV.The restriction enzyme patterns for eight species of mycobacteria were studied.Relative standard deviations of the relative migration times of DNA segments were<3.6%.Compared with AGE,CE is more outstanding in resolution and detection time,and it can be applied as a more effective means to DNA restriction enzyme pattern analysis.

  12. Rapid (ten-minute) pore-gradient electrophoresis of proteins and peptides in Micrograd gels.

    Wrigley, C W; Margolis, J


    Precast gradient gels of short migration length (25 mm) have been developed to provide rapid electrophoretic separation without loss of resolution. These Micrograd gels have been prepared in gel ranges (conventional and unique) to match pore-gradient electrophoresis conditions to proteins/peptides ranging in size from several hundreds to millions. The Hylinx Micrograd gel combines an extreme gel range (6 to 48% polyacrylamide) with a novel crosslinker to provide sieving of polypeptides, and pore-limit electrophoresis of the smallest proteins (e.g. insulin monomer). All gel ranges (such as 3 to 30%) provide zone sharpening in routine analysis of conventional protein mixtures (e.g. serum) within 10 min electrophoresis at 200 to 300 volts. The gels are thin (1 mm) and thus stain quickly, but the gel cassette is of conventional overall width (83 mm), thus fitting many apparatus designs and accommodating 12 samples. The gels are finding valuable use in screening applications, requiring the electrophoretic analysis of many samples, and in cases where a rapid answer is needed, such as monitoring protein purification. The gels have proved particularly useful, in-house, for the latter application in developing Gradipore's new large-scale preparative electrophoresis system, the Gradiflow.

  13. Analysis of anions in ambient aerosols by microchip capillary electrophoresis.

    Liu, Yan; MacDonald, David A; Yu, Xiao-Ying; Hering, Susanne V; Collett, Jeffrey L; Henry, Charles S


    We describe a microchip capillary electrophoresis method for the analysis of nitrate and sulfate in ambient aerosols. Investigating the chemical composition of ambient aerosol particles is essential for understanding their sources and effects. Significant progress has been made towards developing mass spectrometry-based instrumentation for rapid qualitative analysis of aerosols. Alternative methods for rapid quantification of selected high abundance compounds are needed to augment the capacity for widespread routine analysis. Such methods could provide much higher temporal and spatial resolution than can be achieved currently. Inorganic anions comprise a large percentage of particulate mass, with nitrate and sulfate among the most abundant species. While ion chromatography has proven very useful for analyzing extracts of time-integrated ambient aerosol samples collected on filters and for semi-continuous, on-line particle composition measurements, there is a growing need for development of new compact, inexpensive approaches to routine on-line aerosol ion analysis for deployment in spatially dense, atmospheric measurement networks. Microchip capillary electrophoresis provides the necessary speed and portability to address this need. In this report, on-column contact conductivity detection is used with hydrodynamic injection to create a simple microchip instrument for analysis of nitrate and sulfate. On-column contact conductivity detection was achieved using a Pd decoupler placed upstream from the working electrodes. Microchips containing two Au or Pd working electrodes showed a good linear range (5-500 microM) and low limits-of-detection for sulfate and nitrate, with Au providing the lowest detection limits (1 microM) for both ions. The completed microchip system was used to analyze ambient aerosol filter samples. Nitrate and sulfate concentrations measured by the microchip matched the concentrations measured by ion chromatography.

  14. Improved high-throughput DNA fragment analyzer employing horizontal ultrathin gel electrophoresis

    Brumley, Robert L., Jr.; Luckey, John A.


    We are currently developing a significantly improved gel electrophoresis and detection system that will allow more than an order of magnitude enhancement in the speed of DNA fragment analysis. This system is based upon the technique of horizontal ultrathin gel electrophoresis (HUGE) which employs denaturing polyacrylamide gels that are 75 microns thick. Because of the thinness of the gel, very high electric field strengths may be applied without deleterious thermal effects on resolution. Our proprietary fluorescence detector that scans the gel during electrophoresis allows for the simultaneous detection of up to four fluorophores. Because of the efficiency of the system of light collection, the gel can be scanned at speeds fast enough to generate high resolution gel images despite the high speed of separations. In addition, we are able to increase sample density by collecting 500 datapoints across the width of the gel. The resulting instrument has the capability to separate and resolve single-stranded DNA molecules that are between 25 and 300 bases in length from each of 60 lanes in less than 45 minutes. With the advent of 96 lane gels and attendant automation, this instrument will have the ability to analyze 18,432 genotypes per day.

  15. Preparative fractionation of gliadins by electrophoresis at pH 3.1 (A-PAGE).

    Rumbo, M; Chirdo, F G; Giorgieri, S A; Fossati, C A; Añón, M C


    Purification of gliadin subclasses has been difficult since they share many biochemical and physicochemical properties. In this report, the optimization of a preparative electrophoretic method to fractionate gliadins is described. Separation was performed in preparative 7% polyacrylamide gels at pH 3.1. The separation performance was tested using analytical electrophoresis at pH 3.1 and capillary electrophoresis. Preparative gels of different lengths were employed. Using 5-cm preparative gels, several fractions of alpha-, beta-, and gamma-gliadins and fast-mobility and slow-mobility omega-gliadins were collected in 40 h of separation. Resolution was maintained at a protein load of up to 30 mg in each run. The highest efficiency of recovery was achieved using aluminum lactate as the collecting buffer. Fractionation with 10 cm in length gels improved resolution but increased operation times. Gels of 2 cm in length did not separate alpha/beta- and gamma-gliadins efficiently but were useful to separate the two main fractions of omega-gliadins in shorter times. In conclusion, preparative electrophoresis at low pH allowed the separation of alpha-, beta-, gamma-, and omega-gliadin fractions from crude material under nondenaturing conditions.

  16. The fluid mechanics of continuous flow electrophoresis

    Saville, D. A.


    The overall objective is to establish theoretically and confirm experimentally the ultimate capabilities of continuous flow electrophoresis chambers operating in an environment essentially free of particle sedimentation and buoyancy. The efforts are devoted to: (1) studying the effects of particle concentration on sample conductivity and dielectric constant. The dielectric constant and conductivity were identified as playing crucial roles in the behavior of the sample and on the resolving power and throughput of continuous flow devices; and (2) improving the extant mathematical models to predict flow fields and particle trajectories in continuous flow electrophoresis. A dielectric spectrometer was designed and built to measure the complex dielectric constant of a colloidal dispersion as a function of frequency between 500 Hz and 200 kHz. The real part of the signal can be related to the sample's conductivity and the imaginary part to its dielectric constant. Measurements of the dielectric constants of several different dispersions disclosed that the dielectric constants of dilute systems of the sort encountered in particle electrophoresis are much larger than would be expected based on the extant theory. Experiments were carried out to show that, in many cases, this behavior is due to the presence of a filamentary structure of small hairs on the particle surface. A technique for producing electrokinetically ideal synthetic latex particles by heat treating was developed. Given the ubiquitous nature of hairy surfaces with both cells and synthetic particles, it was deemed necessary to develop a theory to explain their behavior. A theory for electrophoretic mobility of hairy particles was developed. Finally, the extant computer programs for predicting the structure of electro-osmotically driven flows were extended to encompass flow channels with variable wall mobilities.

  17. Capillary electrophoresis-mass spectrometry of carbohydrates.

    Zaia, Joseph


    The development of methods for capillary electrophoresis (CE) with on-line mass spectrometric detection (CE/MS) is driven by the need for accurate, robust, and sensitive glycomics analysis for basic biomedicine, biomarker discovery, and analysis of recombinant protein therapeutics. One important capability is to profile glycan mixtures with respect to the patterns of substituents including sialic acids, acetate, sulfate, phosphate, and other groups. There is additional need for an MS-compatible separation system capable of resolving carbohydrate isomers. This chapter summarizes applications of CS/MS to analysis of carbohydrates, glycoproteins, and glycopeptides that have appeared since 2008. Readers are referred to recent comprehensive reviews covering earlier publications.

  18. Pulsed field gel electrophoresis a practical guide

    Birren, Bruce


    Pulsed Field Gel Electrophoresis: A Practical Guide is the first laboratory manual to describe the theory and practice of this technique. Based on the authors' experience developing pulsed field gel instruments and teaching procedures, this book provides everything a researcher or student needs to know in order to understand and carry out pulsed field gel experiments. Clear, well-tested protocols assume only that users have a basic familiarity with molecular biology. Thorough coverage of useful data, theory, and applications ensures that this book is also a lasting resource for more adv

  19. Hybrid slab-microchannel gel electrophoresis system

    Balch, Joseph W.; Carrano, Anthony V.; Davidson, James C.; Koo, Jackson C.


    A hybrid slab-microchannel gel electrophoresis system. The hybrid system permits the fabrication of isolated microchannels for biomolecule separations without imposing the constraint of a totally sealed system. The hybrid system is reusable and ultimately much simpler and less costly to manufacture than a closed channel plate system. The hybrid system incorporates a microslab portion of the separation medium above the microchannels, thus at least substantially reducing the possibility of non-uniform field distribution and breakdown due to uncontrollable leakage. A microslab of the sieving matrix is built into the system by using plastic spacer materials and is used to uniformly couple the top plate with the bottom microchannel plate.

  20. Multicapillary electrophoresis disposable cartridge for bioseparations

    Amirkhanian, Varoujan D.; Liu, Ming-Sun


    We have successfully demonstrated the development of a compact and cost-effective parallel multi-channel capillary electrophoresis system for bio-molecules analysis. The automated process includes a buffer/gel replenishment mechanism, high voltage control of fluidics and an automated sample tray transport capability. The bio-separation/analysis occurs in a disposable cartridge containing multi-column capillaries with integrated excitation optical fibers, detection micro-optics and a buffer reservoir common to all separation channels. Tests of this fully integrated system indicate, that large quantities of biological samples can be analyzed automatically in a short period with highly sensitive fluorescence detection.

  1. Polystyrene latex separations by continuous flow electrophoresis on the Space Shuttle

    Snyder, R. S.; Rhodes, P. H.; Miller, T. Y.; Micale, F. J.; Mann, R. V.


    The seventh mission of the Space Shuttle carried two NASA experiments in the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system. The objectives were to test the operation of continuous flow electrophoresis in a reduced gravity environment using stable particles with established electrokinetic properties and specifically to evaluate the influence of the electrical properties of the sample constituents on the resolution of the continuous flow electrophoretic device. Polystrene latex microspheres dispersed in a solution with three times the electrical conductivity of the curtain buffer separated with a significantly larger band spread compared to the second experiment under matched conductivity conditions. It is proposed that the sample of higher electrical conductivity distorted the electric field near the sample stream so that the polystyrene latex particles migrated toward the chamber walls where electroosmosis retarded and spread the sample.

  2. Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

    Cong, Yongzheng; Katipamula, Shanta; Geng, Tao; Prost, Spencer A.; Tang, Keqi; Kelly, Ryan T.


    A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.

  3. A forensic laboratory tests the Berkeley microfabricated capillary array electrophoresis device.

    Greenspoon, Susan A; Yeung, Stephanie H I; Johnson, Kelly R; Chu, Wai K; Rhee, Han N; McGuckian, Amy B; Crouse, Cecelia A; Chiesl, Thomas N; Barron, Annelise E; Scherer, James R; Ban, Jeffrey D; Mathies, Richard A


    Miniaturization of capillary electrophoresis onto a microchip for forensic short tandem repeat analysis is the initial step in the process of producing a fully integrated and automated analysis system. A prototype of the Berkeley microfabricated capillary array electrophoresis device was installed at the Virginia Department of Forensic Science for testing. Instrument performance was verified by PowerPlex 16 System profiling of single source, sensitivity series, mixture, and casework samples. Mock sexual assault samples were successfully analyzed using the PowerPlex Y System. Resolution was assessed using the TH01, CSF1PO, TPOX, and Amelogenin loci and demonstrated to be comparable with commercial systems along with the instrument precision. Successful replacement of the Hjerten capillary coating method with a dynamic coating polymer was performed. The accurate and rapid typing of forensic samples demonstrates the successful technology transfer of this device into a practitioner laboratory and its potential for advancing high-throughput forensic typing.

  4. Recent advances in amino acid analysis by capillary electrophoresis.

    Poinsot, Véréna; Carpéné, Marie-Anne; Bouajila, Jalloul; Gavard, Pierre; Feurer, Bernard; Couderc, François


    This paper describes the most important articles that have been published on amino acid analysis using CE during the period from June 2009 to May 2011 and follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138) and Poinsot et al. (Electrophoresis 2003, 24, 4047-4062; Electrophoresis 2006, 27, 176-194; Electrophoresis 2008, 29, 207-223; Electrophoresis 2010, 31, 105-121). We present new developments in amino acid analysis with CE, which are reported describing the use of lasers or light emitting diodes for fluorescence detection, conductimetry electrochemiluminescence detectors, mass spectrometry applications, and lab-on-a-chip applications using CE. In addition, we describe articles concerning clinical studies and neurochemical applications of these techniques.

  5. Stacking gels: A method for maximising output for pulsed-field gel electrophoresis

    Heng See


    Full Text Available Pulsed field gel electrophoresis (PFGE, the gold standard of molecular typing methods, has a major disadvantage of an unusually long electrophoretic time. From the original protocol of 6 days, it was modified to 3 days and subsequently to a single day. We describe the procedure of stacking five to six gels one on top of another in order to increase and maximize the output in a shorter time without compromising the resolution and reproducibility. All the variables that affect pulsed field gels during electrophoresis were taken into consideration. We firstly optimized the parameters to be used and secondly determined whether stacking of five to six gels had any effect on the molecular separation during electrophoresis in comparison with a single gel run. DNA preparation, restriction, electrophoresis, staining and gel documentation was carried out based on previously published methods. Gels were analysed using BioNumerics and dice coefficient and unweighted pair group methods were used to generate dendrograms based on 1.5% tolerance values. Identical band profiles and band resolution-separation were seen in the PFGE patterns with single gel and multiple stacking gels. Cluster analysis further strengthened the fact that results from stacking gels were reproducible and comparable with a single gel run. This method of stacking gels saves time and maximizes the output at the same time. The run time for a single gel was about 28 hours, but with six stacked gels the run time was 54 hours compared with 28 x 6 = 168 hours if they were run separately as single gels thus saving time of 67.86%. Beside the big factor of saving time, stacking gels save resources (electricity, reagents, water, chemicals and working time by increasing the sample throughput in a shorter time without compromising on quality of data. But optimization of working parameters is vital depending on the PFGE system used.

  6. Micro-injector for capillary electrophoresis.

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C


    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core.

  7. Fractionation of mineral species by electrophoresis

    Dunning, J. D.; Herren, B. J.; Tipps, R. W.; Snyder, R. S.


    The fractionation of fine-grained aggregates into their major components is a problem in many scientific areas including earth and planetary science. Electrophoresis, the transport of electrically charged particles, immersed in a suspension medium, by a direct current field (Bier, 1959), was employed in this study as a means of separating simulated lunar soil into its constituent minerals. In these tests, conducted in a static analytical cylindrical microelectrophoresis apparatus, samples of simulated lunar soil and samples of pure mineral constituents were placed in the chamber; the electrophoretic mobilities of the lunar soil and the individual mineral constituents were measured. In most of the suspension buffers employed separability was indicated, on the basis of differences in mobility, for all the constituent mineral species except ilmenite and pyroxene, which were not efficiently separable in any of the buffers. Although only a few suspension media were employed, the success of this initial study suggests that electrophoresis may be an important mineral fractionation option in fine-grained aggregate processing.

  8. Gel Electrophoresis of Gold-DNA Nanoconjugates

    T. Pellegrino


    Full Text Available Gold-DNA conjugates were investigated in detail by a comprehensive gel electrophoresis study based on 1200 gels. A controlled number of single-stranded DNA of different length was attached specifically via thiol-Au bonds to phosphine-stabilized colloidal gold nanoparticles. Alternatively, the surface of the gold particles was saturated with single stranded DNA of different length either specifically via thiol-Au bonds or by nonspecific adsorption. From the experimentally determined electrophoretic mobilities, estimates for the effective diameters of the gold-DNA conjugates were derived by applying two different data treatment approaches. The first method is based on making a calibration curve for the relation between effective diameters and mobilities with gold nanoparticles of known diameter. The second method is based on Ferguson analysis which uses gold nanoparticles of known diameter as reference database. Our study shows that effective diameters derived from gel electrophoresis measurements are affected with a high error bar as the determined values strongly depend on the method of evaluation, though relative changes in size upon binding of molecules can be detected with high precision. Furthermore, in this study, the specific attachment of DNA via gold-thiol bonds to Au nanoparticles is compared to nonspecific adsorption of DNA. Also, the maximum number of DNA molecules that can be bound per particle was determined.

  9. Capillary electrophoresis methods for microRNAs assays: A review

    Ban, Eunmi; Song, Eun Joo, E-mail:


    Highlights: • A review of CE analysis of miRNAs. • Summary of developments and applications of CE systems in miRNA studies. • Applications and development of microchip-based CE for rapid analysis of miRNA. - Abstract: MicroRNAs (miRNAs) are short noncoding RNAs that conduct important roles in many cellular processes such as development, proliferation, differentiation, and apoptosis. In particular, circulating miRNAs have been proposed as biomarkers for cancer, diabetes, cardiovascular disease, and other illnesses. Therefore, determination of miRNA expression levels in various biofluids is important for the investigation of biological processes in health and disease and for discovering their potential as new biomarkers and drug targets. Capillary electrophoresis (CE) is emerging as a useful analytical tool for analyzing miRNA because of its simple sample preparation steps and efficient resolution of a diverse size range of compounds. In particular, CE with laser-induced fluorescence detection is a promising and relatively rapidly developing tool with the potential to provide high sensitivity and specificity in the analysis of miRNAs. This paper covers a short overview of the recent developments and applications of CE systems in miRNA studies in biological and biomedical areas.

  10. Analysis of roller pen inks by capillary zone electrophoresis

    ZHAO Pengcheng; WANG Yanji; XU Yuanyuan; YAO Lijuan


    The analysis of roller pen inks has become more and more important in fraudulent document examination because of the extensive use of roller pens in financial documents.Capillary electrophoresis with powerful resolution was applied for the analysis of roller pen inks.The experiment focused on the optimization of the separation of the extract from commercially available roller pen entries.A better separation electropherogram was obtained when a 20 mM borate buffer at pH 8.5 and a fused silica capillary with an inner diameter of 100 μm with a total length of 47 (40 cm to the detector window)were used.Five inks from roller pens of different manufacturers and countries were analyzed,and their electropherograms showed that most patterns are distinctly different from each other.Capillary with inner diameter of 100 μm increased the intensity of determination;therefore,color dyes were identified in the visible range and were able to provide more information for comparing types of roller pen inks.

  11. Chip electrophoresis of gelatin-based nanoparticles.

    Weiss, Victor U; Lehner, Angela; Grombe, Ringo; Marchetti-Deschmann, Martina; Allmaier, Günter


    Recently, biodegradable nanoparticles received increasing attention for pharmaceutical applications as well as applications in the food industry. With the current investigation we demonstrate chip electrophoresis of fluorescently (FL) labeled gelatin nanoparticles (gelatin NPs) on a commercially available instrument. FL labeling included a step for the removal of low molecular mass material (especially excess dye molecules). Nevertheless, for the investigated gelatin NP preparation two analyte peaks, one very homogeneous with an electrophoretic net mobility of μ = -24.6 ± 0.3 × 10(-9) m(2) /Vs at the peak apex (n = 17) and another more heterogeneous peak with μ between approximately -27.2 ± 0.2 × 10(-9) m(2) /Vs and -36.6 ± 0.2 × 10(-9) m(2) /Vs at the peak beginning and end point (n = 11, respectively) were recorded. Filtration allowed enrichment of particles in the size range of approximately 35 nm (pore size employed for concentration of gelatin NPs) to 200 nm (pore size employed during FL labeling). This corresponded to the very homogeneous peak linking it to gelatin NPs, whereas the more heterogeneous peak probably corresponds to gelatin not cross-linked to such a high degree (NP building blocks). Several further gelatin NP preparations were analyzed according to the same protocol yielding peaks with electrophoretic net mobilities between -23.3 ± 0.3 × 10(-9) m(2) /Vs and -28.9 ± 0.2 × 10(-9) m(2) /Vs at peak apexes (n = 15 and 6). Chip electrophoresis allows analyte separation in less than two minutes (including electrophoretic sample injection). Together with the high sensitivity of the FL detection - the LOD as derived for the first main peak of the applied dye from the threefold standard deviation of the background noise values 80 pM for determined separation conditions - this leads to a very promising high throughput separation technique especially for the analysis of bionanoparticles. For gelatin NP preparations, chip electrophoresis

  12. Cycloaliphatic epoxy resin coating for capillary electrophoresis.

    Shah, Roopa S; Wang, Qinggang; Lee, Milton L


    Coating the interior surface of a fused-silica capillary with a polymeric material has long been used in capillary electrophoresis (CE) to reduce or eliminate electroosmotic flow and suppress adsorption. A cycloaliphatic epoxide-based resin was bonded to silane treated capillaries and crosslinked with a curing agent. The epoxy resin coating significantly reduced electroosmotic flow over a pH range of 3-10. This coating was sufficiently hydrophilic to suppress protein adsorption. The epoxy resin coated capillary was used to separate several acidic and basic proteins and peptides. Separation efficiencies greater than 400,000 theoretical plates were achieved. The relative standard deviations in migration times for proteins were methods.

  13. Novel absorption detection techniques for capillary electrophoresis

    Xue, Yongjun [Iowa State Univ., Ames, IA (United States)


    Capillary electrophoresis (CE) has emerged as one of the most versatile separation methods. However, efficient separation is not sufficient unless coupled to adequate detection. The narrow inner diameter (I.D.) of the capillary column raises a big challenge to detection methods. For UV-vis absorption detection, the concentration sensitivity is only at the μM level. Most commercial CE instruments are equipped with incoherent UV-vis lamps. Low-brightness, instability and inefficient coupling of the light source with the capillary limit the further improvement of UV-vis absorption detection in CE. The goals of this research have been to show the utility of laser-based absorption detection. The approaches involve: on-column double-beam laser absorption detection and its application to the detection of small ions and proteins, and absorption detection with the bubble-shaped flow cell.

  14. Antibody enhancement of free-flow electrophoresis

    Cohly, H. H. P.; Morrison, Dennis R.; Atassi, M. Zouhair


    Specific T cell clones and antibodies (ABs) were developed to study the efficiency of purifying closely associated T cells using Continuous Flow Electrophoresis System. Enhanced separation is accomplished by tagging cells first with ABs directed against the antigenic determinants on the cell surface and then with ABs against the Fc portion of the first AB. This second AB protrudes sufficiently beyond the cell membrane and glycocalyx to become the major overall cell surface potential determinant and thus causes a reduction of electrophoretic mobility. This project was divided into three phases. Phase one included development of specific T cell clones and separation of these specific clones. Phase two extends these principles to the separation of T cells from spleen cells and immunized lymph node cells. Phase three applies this double antibody technique to the separation of T cytotoxic cells from bone marrow.

  15. Development of novel separation techniques for biological samples in capillary electrophoresis

    Chang, Huan -Tsung [Iowa State Univ., Ames, IA (United States)


    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  16. A tunable isoelectric focusing via moving reaction boundary for two-dimensional gel electrophoresis and proteomics.

    Guo, Chen-Gang; Shang, Zhi; Yan, Jian; Li, Si; Li, Guo-Qing; Liu, Rong-Zhong; Qing, Ying; Fan, Liu-Yin; Xiao, Hua; Cao, Cheng-Xi


    Routine native immobilized pH gradient isoelectric focusing (IPG-IEF) and two-dimensional gel electrophoresis (2DE) are still suffering from unfortunate reproducibility, poor resolution (caused by protein precipitation) and instability in characterization of intact protein isoforms and posttranslational modifications. Based on the concept of moving reaction boundary (MRB), we firstly proposed a tunable non-IPG-IEF system to address these issues. By choosing proper pairs of catholyte and anolyte, we could achieve desired cathodic and anodic migrating pH gradients in non-IPG-IEF system, effectively eliminating protein precipitation and uncertainty of quantitation existing in routine IEF and 2DE, and enhancing the resolution and sensitivity of IEF. Then, an adjustable 2DE system was developed by combining non-IPG-IEF with polyacrylamide gel electrophoresis (PAGE). The improved 2DE was evaluated by testing model proteins and colon cancer cell lysates. The experiments revealed that (i) a tunable pH gradient could be designed via MRB; (ii) up to 1.65 fold improvement of resolution was achieved via non-IPG-IEF; (iii) the sensitivity of developed techniques was increased up to 2.7 folds; and (iv) up to about 16.4% more protein spots could be observed via the adjustable 2DE as compared with routine one. The developed techniques might contribute to complex proteome research, especially for screening of biological marker and analysis of extreme acidic/alkaline proteins. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Gel Electrophoresis on a Budget to Dye for

    Yu, Julie H.


    Gel electrophoresis is one of the most important tools used in molecular biology and has facilitated the entire field of genetic engineering by enabling the separation of nucleic acids and proteins. However, commercial electrophoresis kits can cost up to $800 for each setup, which is cost prohibitive for most classroom budgets. This article…

  18. Gel Electrophoresis on a Budget to Dye for

    Yu, Julie H.


    Gel electrophoresis is one of the most important tools used in molecular biology and has facilitated the entire field of genetic engineering by enabling the separation of nucleic acids and proteins. However, commercial electrophoresis kits can cost up to $800 for each setup, which is cost prohibitive for most classroom budgets. This article…

  19. Inexpensive and Safe DNA Gel Electrophoresis Using Household Materials

    Ens, S.; Olson, A. B.; Dudley, C.; Ross, N. D., III; Siddiqi, A. A.; Umoh, K. M.; Schneegurt, M. A.


    Gel electrophoresis is the single most important molecular biology technique and it is central to life sciences research, but it is often too expensive for the secondary science classroom or homeschoolers. A simple safe low-cost procedure is described here that uses household materials to construct and run DNA gel electrophoresis. Plastic…

  20. Potential of capillary electrophoresis for the profiling of propolis

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.


    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC) wit

  1. Potential of capillary electrophoresis for the profiling of propolis

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.


    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC)

  2. Inexpensive and Safe DNA Gel Electrophoresis Using Household Materials

    Ens, S.; Olson, A. B.; Dudley, C.; Ross, N. D., III; Siddiqi, A. A.; Umoh, K. M.; Schneegurt, M. A.


    Gel electrophoresis is the single most important molecular biology technique and it is central to life sciences research, but it is often too expensive for the secondary science classroom or homeschoolers. A simple safe low-cost procedure is described here that uses household materials to construct and run DNA gel electrophoresis. Plastic…

  3. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.


    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862.2485 Section 862.2485 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An...

  4. Separation and analysis of triazine herbcide residues by capillary electrophoresis.

    Elbashir, Abdalla A; Aboul-Enein, Hassan Y


    Triazines are widely used in agriculture around the world as selective pre- and post-emergence herbicides for the control of broad leaf and grassy weeds. With high toxicity and persistence, triazines can contaminate the environment and crops, so the development of rapid and sensitive methods for the determination of different triazines is necessary. Capillary electrophoresis comprises a group of techniques used to separate chemical mixtures. Analytical separation is based on different electrophoretic mobilities. This review focuses on the analysis of triazine herbicides with different modes of capillary electrophoresis, including capillary zone electrophoresis, micellar electrokinetic capillary electrophoresis, capillary electrochromatography and nonaqueous capillary electrophoresis. Determinations of triazines in various matrices such as surface water, groundwater, vegetables, soil and grains are emphasized.

  5. Tris-acetate polyacrylamide gradient gel electrophoresis for the analysis of protein oligomerization.

    Cubillos-Rojas, Monica; Schneider, Taiane; Sánchez-Tena, Susana; Bartrons, Ramon; Ventura, Francesc; Rosa, Jose Luis


    Here we report a new approach for studying protein oligomerization in cells using a single electrophoresis gel. We combined the use of a crosslinking reagent for sample preparation, such as glutaraldehyde, with the analysis of oligomers by Tris-acetate polyacrylamide gel electrophoresis. The use of a 3-15% Tris-acetate polyacrylamide gradient gel allows for the simultaneous analysis of proteins of masses ranging from 10 to 500 kDa. We showed the usefulness of this method for analyzing endogenous p53 oligomerization with high resolution and sensitivity in human cells. Oligomerization analysis was dependent on the crosslinker concentration used. We also showed that this method could be used to study the regulation of oligomerization. In all experiments, Tris-acetate polyacrylamide gel electrophoresis proved to be a robust, manageable, and cost- and time-efficient method that provided excellent results using a single gel. This approach can be easily extrapolated to the study of other oligomers. All of these features make this method a highly useful tool for the analysis of protein oligomerization.

  6. Charge Effect on the Quantum Dots-Peptide Self-Assembly Using Fluorescence Coupled Capillary Electrophoresis.

    Wang, Jianhao; Li, Jingyan; Teng, Yiwan; Bi, Yanhua; Hu, Wei; Li, Jinchen; Wang, Cheli; Qiu, Lin; Jiang, Pengju


    We present a molecular characterization of metal-affinity driven self-assembly between CdSe-ZnS quantum dots and a series of hexahistidine peptides with different charges. In particular, we uti- lized fluorescence coupled capillary electrophoresis to test the self-assembly process of quantum dots with peptides in solution. Four peptides with different charges can be efficiently separated by fluorescence coupled capillary electrophoresis. The migration time appeared to be influenced by the charges of the peptide. In addition, the kinetics of self-assembly process of quantum dots with one of the peptides manifested a bi-phasic kinetics followed by a saturating stage. This work revealed that there exist two types of binding sites on the surface of quantum dots for peptide 1: one type termed "high priority" binding site and a "low priority" site which is occupied after the first binding sites are fully occupied. The total self-assembly process finishes in solution within 80 s. Our work represents the systematic investigation of the details of self-assembly kinetics utilizing high-resolution fluorescence coupled capillary electrophoresis. The charge effect of peptide coating quantum dots provides a new way of preparing bioprobes.

  7. Dynamic computer simulations of electrophoresis: a versatile research and teaching tool.

    Thormann, Wolfgang; Breadmore, Michael C; Caslavska, Jitka; Mosher, Richard A


    Software is available, which simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. These dynamic models are based upon equations derived from the transport concepts such as electromigration, diffusion, electroosmosis and imposed hydrodynamic buffer flow that are applied to user-specified initial distributions of analytes and electrolytes. They are able to predict the evolution of electrolyte systems together with associated properties such as pH and conductivity profiles and are as such the most versatile tool to explore the fundamentals of electrokinetic separations and analyses. In addition to revealing the detailed mechanisms of fundamental phenomena that occur in electrophoretic separations, dynamic simulations are useful for educational purposes. This review includes a list of current high-resolution simulators, information on how a simulation is performed, simulation examples for zone electrophoresis, ITP, IEF and EKC and a comprehensive discussion of the applications and achievements.

  8. Analysis of seven STR human loci for paternity testing by microchip electrophoresis

    Karina Fraige


    Full Text Available The aim of this work was to evaluate two paternity cases by microchip electrophoresis and the validation of the methodology by comparison of the results with those obtained in a commercial genetic analyzer. It was observed that when working with tetranucleotide regions, in which the minimal difference between the alleles was only four base pairs, the commercial microchip system did not present the resolution and repeatability needed. Nevertheless, the relative standard deviation was between 0 and 1.2% and the fragments detected were within the expected size ranges as described in the literature.

  9. Applicability of chemically modified capillaries in chiral capillary electrophoresis for methamphetamine profiling.

    Iwata, Yuko T; Mikuma, Toshiyasu; Kuwayama, Kenji; Tsujikawa, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Inoue, Hiroyuki


    We examined the applicability of chemically modified capillaries on the chiral capillary electrophoresis of essential compounds for methamphetamine (MA) profiling (MA, amphetamine, ephedrine, pseudoephedrine, norephedrine, and norpseudoephedrine) using highly sulfated γ-cyclodextrin as a chiral selector. Four types of chemically modified capillaries, namely, FunCap-CE/Type D (possessing diol groups), Type A (amino groups), Type C (carboxyl groups), and Type S (sulfate groups), were evaluated. Repeatability, speed, and good chiral resolution sufficient for routine MA profiling were achieved with the Type S capillary.

  10. Agarose gel electrophoresis and polyacrylamide gel electrophoresis for visualization of simple sequence repeats.

    Anderson, James; Wright, Drew; Meksem, Khalid


    In the modern age of genetic research there is a constant search for ways to improve the efficiency of plant selection. The most recent technology that can result in a highly efficient means of selection and still be done at a low cost is through plant selection directed by simple sequence repeats (SSRs or microsatellites). The molecular markers are used to select for certain desirable plant traits without relying on ambiguous phenotypic data. The best way to detect these is the use of gel electrophoresis. Gel electrophoresis is a common technique in laboratory settings which is used to separate deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) by size. Loading DNA and RNA onto gels allows for visualization of the size of fragments through the separation of DNA and RNA fragments. This is achieved through the use of the charge in the particles. As the fragments separate, they form into distinct bands at set sizes. We describe the ability to visualize SSRs on slab gels of agarose and polyacrylamide gel electrophoresis.

  11. Higher sensitivity of capillary electrophoresis in detecting hemoglobin A2'compared to traditional gel electrophoresis.

    Oleske, Deanna Alicia; Huang, Richard Sheng Poe; Dasgupta, Amitava; Nguyen, Andy; Wahed, Amer


    HbA2' (also called Hb B2) is the most common delta-globin chain defect and is reported to occur in 1-2% of the African American population. The major clinical significance of HbA2' is that the failure to detect it might lead to an underestimation of the total HbA2, leading to failure to diagnose β-thalassemia minor. In order to diagnose β-thalassemia minor, both HbA2 and HbA2' levels must be combined.Hb A2' accounts for a small percentage (1-2%) of the total hemoglobin in heterozygotes. It is difficult to detect this small amount by traditional gel electrophoresis. Using HPLC Hb A2' is easily detected as it produces a minor peak in the S window. Other conditions which might interfere with detection of HbA2' by HPLC include Hb S trait or Hb SS disease (Hb A2' hidden in the S peak), transfused Hb SS (Hb S peak may be very small), Hb C trait or Hb CC disease (glycosylated Hb C elutes in the S window), and Hb G (Hb G2 elutes in the S window). All of the above conditions, including Hb A2', occur most commonly in the same ethnic group (African American). We reviewed 654 consecutive cases over a period of three months for the presence of Hb A2' in our laboratory where capillary electrophoresis is used as the primary diagnostic tool. We detected seven cases (1.07 %) of HbA2'. In contrast, we did not detect any HbA2' using conventional gel electrophoresis in the last one year (2,580 cases). Although in none of the seven cases the sum of Hb A2 and Hb A2' exceeded 3.5%, we believe that capillary electrophoresis allows for a better detection of Hb A2' than gel electrophoresis and HPLC. © 2014 by the Association of Clinical Scientists, Inc.

  12. Modification of gel architecture and TBE/TAE buffer composition to minimize heating during agarose gel electrophoresis.

    Sanderson, Brian A; Araki, Naoko; Lilley, Jennifer L; Guerrero, Gilberto; Lewis, L Kevin


    Agarose gel electrophoresis of DNA and RNA is routinely performed using buffers containing either Tris, acetate, and EDTA (TAE) or Tris, borate, and EDTA (TBE). Gels are run at a low, constant voltage (∼10 V/cm) to minimize current and asymmetric heating effects, which can induce band artifacts and poor resolution. In this study, alterations of gel structure and conductive media composition were analyzed to identify factors causing higher electrical currents during horizontal slab gel electrophoresis. Current was reduced when thinner gels and smaller chamber buffer volumes were used, but was not influenced by agarose concentration or the presence of ethidium bromide. Current was strongly dependent on the amount and type of EDTA used and on the concentrations of the major acid-base components of each buffer. Interestingly, resolution and the mobilities of circular versus linear plasmid DNAs were also affected by the chemical form and amount of EDTA. With appropriate modifications to gel structure and buffer constituents, electrophoresis could be performed at high voltages (20-25 V/cm), reducing run times by up to 3-fold. The most striking improvements were observed with small DNAs and RNAs (10-100 bp): high voltages and short run times produced sharper bands and higher resolution. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Major proteins in normal human lymphocyte subpopulations separated by fluorescence-activated cell sorting and analyzed by two-dimensional gel electrophoresis

    Madsen, P S; Hokland, M; Ellegaard, J;


    We have compared the overall patterns of protein synthesis of normal human lymphocyte subpopulations taken from five volunteers using high resolution two-dimensional gel electrophoresis. The lymphocytes were isolated using density gradient centrifugation, labeled with subtype-specific MoAbs, and ...

  14. Carboxymethyl-β-cyclodextrin for Chiral Separation of Amino Acids Derivatized with Fluorescene-5-isothiocyanate by Capillary Electrophoresis and Laser-induced Fluorescence Detection

    Yu Yun CHEN; Wei WANG; Wei Ping YANG; Zhu Jun ZHANG


    A method using carboxymethyl-β-cyclodextrin(CM-β-CD) as selector for chiral separation of amino acids by capillary electrophoresis and laser-induced fluorescence detection was studied. Resolution was better than that obtained byβ-CD or HP-β-CD.

  15. Improving the sensitivity in chiral capillary electrophoresis.

    Sánchez-López, Elena; Marina, María Luisa; Crego, Antonio L


    CE is known for being one of the most powerful analytical techniques when performing enantioseparations due to its numerous advantages such as excellent separation efficiency and extremely low solvents and reagents consumption, all of them derived from the capillary small dimensions. Moreover, it is worth highlighting that unlike in chromatographic techniques, in CE the chiral selector is generally within the separation medium instead of being attached to the separation column which makes the method optimization a more versatile task. Despite its numerous advantages, when using UV-Vis detection, CE lacks of sensitivity detection due to its short optical path length derived from the narrow separation capillary. This issue can be overcome by means of different approaches, either by sample treatment procedures or by in-capillary preconcentration techniques or even by employing detection systems more sensitive than UV-Vis, such as LIF or MS. The present review assembles the latest contributions regarding improvements of sensitivity in chiral CE published from June 2013 until May 2015, which follows the works included in a previous review reported by Sánchez-Hernández et al. [Electrophoresis 2014, 35, 12-27].

  16. Capillary electrophoresis and the clinical laboratory.

    Jabeen, Rukhsana; Payne, Deborah; Wiktorowicz, John; Mohammad, Amin; Petersen, John


    Over the past 15 years, CE as an analytical tool has shown great promise in replacing many conventional clinical laboratory methods, such as electrophoresis and HPLC. CE's appeal was that it was fast, used very small amounts of sample and reagents, was extremely versatile, and was able to separate large and small analytes, whether neutral or charged. Because of this versatility, numerous methods have been developed for analytes that are of clinical interest. Other than molecular diagnostic and forensic laboratories CE has not been able to make a major impact in the United States. In contrast, in Europe and Japan an increasing number of clinical laboratories are using CE. Now that automated multicapillary instruments are commercially available along with cost-effective test kits, CE may yet be accepted as an instrument that will be routinely used in the clinical laboratories. This review will focus on areas where CE has the potential to have the greatest impact on the clinical laboratory. These include analyses of proteins found in serum and urine, hemoglobin (A1c and variants), carbohydrate-deficient transferrin, forensic and therapeutic drug screening, and molecular diagnostics.

  17. Nitromethane as solvent in capillary electrophoresis.

    Subirats, Xavier; Porras, Simo P; Rosés, Martí; Kenndler, Ernst


    Nitromethane has several properties that make it an interesting solvent for capillary electrophoresis especially for lipophilic analytes that are not sufficiently soluble in water: freezing and boiling points are suitable for laboratory conditions, low viscosity leads to favourable electrophoretic mobilities, or an intermediate dielectric constant enables dissolution of electrolytes. In the present work we investigate the change of electrophoretically relevant analyte properties - mobilities and pKa values - in nitromethane in dependence on the most important experimental conditions determined by the background electrolyte: the ionic strength, I, and the pH. It was found that the mobility decreases with increasing ionic strength (by, e.g. up to 30% from I = 0 to 50 mmol/L) according to theory. An appropriate pH scale is established by the aid of applying different concentration ratios of a buffer acid with known pKa and its conjugate base. The mobility of the anionic analytes (from weak neutral acids) depends on the pH with the typical sigmoidal curve in accordance with theory. The pKa of neutral acids derived from these curves is shifted by as much as 14 pK units in nitromethane compared to water. Both findings confirm the agreement of the electrophoretic behaviour of the analytes with theories of electrolyte solutions. Separation of several neutral analytes was demonstrated upon formation of charged complexes due to heteroconjugation with chloride as ionic constituent of the background electrolyte.

  18. Fabricating PFPE Membranes for Capillary Electrophoresis

    Lee, Michael C.; Willis, Peter A.; Greer, Frank; Rolland, Jason


    A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist).

  19. Electrophoresis of particles with Navier velocity slip.

    Park, Hung Mok


    In the present investigation, it is found that the electrophoretic mobility of hydrophobic particles is affected not only by the zeta potential but also by the velocity slip at the particle surface. From a physicochemical viewpoint, zeta potential represents the surface charge properties and the slip coefficient indicates the hydrophobicity of the particle surface. Thus, it is necessary to separate the contribution of zeta potential from that of slip coefficient to the particle mobility, since zeta potential can be changed by varying the bulk ionic concentration while the slip coefficient can be modified by adjusting surfactant concentration. In the present investigation, a method is devised that allows a simultaneous estimation of zeta potential and slip coefficient of micro and nanoparticles using measurements of electrophoretic mobility at various bulk ionic concentrations. Employing a nonlinear curve-fitting technique and an analytic solution of electrophoresis for a particle with velocity slip, the present technique predicts both zeta potential and slip coefficient simultaneously with reasonable accuracy using the measured values of electrophoretic mobility at various bulk ionic concentrations.

  20. Gel Electrophoresis of Proteins for the Identification of Crop Varieties

    LAN Hai-yan; LI Li-hui


    With the development of the international trade and agricultural science and technology, especially after the execution of the rules on protection of new plant varieties, considerable emphasis has been placed on variety identification. Many evidences have suggested that gel electrophoresis have great influence on this area. This paper reviewed study status of various gel electrophoresis, including development of the methods, comparison of these techniques, influence factors, practical applications, achievements obtained and aspects in the future study. With the wider range on protection of new plant varieties in China, electrophoresis will play a more important role in variety identification.

  1. Thermal image filtering by bi-dimensional empirical mode decomposition

    Gavriloaia, Bogdan-Mihai; Vizireanu, Constantin-Radu; Fratu, Octavian; Mara, Constantin; Vizireanu, Dragos-Nicolae; Preda, Radu; Gavriloaia, Gheorghe


    The abnormal function of cells can be detected by anatomic or physiological registrations. Most of modern approaches, as ultrasound, RMN or CT, show anatomic parametric modifications of tissues or organs. They highlight areas with a larger diameter 1 cm. In the case of skin or superficial cancers, local temperature is different, and it can be put out by thermal imager. Medical imaging is a leading role in modern diagnosis for abnormal or normal tissues or organs. Some information has to be improved for a better diagnosis by reducing or removing some unwanted information like noise affecting image texture. The traditional technologies for medical image enhancement use spatial or frequency domain methods, but whole image processing will hide both partial and specific information for human signals. A particular kind of medical images is represented by thermal imaging. Recently, these images were used for skin or superficial cancers diagnosis, but very clear outlines of certain alleged affected areas need to be shown. Histogram equalization cannot highlights the edges and control the effects of enhancement. A new filtering method was introduced by Huang by using the empirical mode decomposition, EMD. An improved filtering method for thermal images, based on EMD, is presented in this paper, and permits to analyze nonlinear and non-stationary data by the adaptive decomposition into intrinsic mode surfaces. The results, evaluated by SNR ratios, are compared with other filtering methods.

  2. Voltage-programming-based capillary gel electrophoresis for the fast detection of angiotensin-converting enzyme insertion/deletion polymorphism with high sensitivity.

    Woo, Nain; Kim, Su-Kang; Kang, Seong Ho


    A voltage-programming-based capillary gel electrophoresis method with a laser-induced fluorescence detector was developed for the fast and highly sensitive detection of DNA molecules related to angiotensin-converting enzyme insertion/deletion polymorphism, which has been reported to influence predisposition to various diseases such as cardiovascular disease, high blood pressure, myocardial infarction, and Alzheimer's disease. Various voltage programs were investigated for fast detection of specific DNA molecules of angiotensin-converting enzyme insertion/deletion polymorphism as a function of migration time and separation efficiency to establish the effect of voltage strength to resolution. Finally, the amplified products of the angiotensin-converting enzyme insertion/deletion polymorphism (190 and 490 bp DNA) were analyzed in 3.2 min without losing resolution under optimum voltage programming conditions, which were at least 75 times faster than conventional slab gel electrophoresis. In addition, the capillary gel electrophoresis method also successfully applied to the analysis of real human blood samples, although no polymorphism genes were detected by slab gel electrophoresis. Consequently, the developed voltage-programming capillary gel electrophoresis method with laser-induced fluorescence detection is an effective, rapid analysis technique for highly sensitive detection of disease-related specific DNA molecules. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Urinary Glycosaminoglycan Electrophoresis With Optimized Keratan Sulfate Separation Using Peltier System for the Screening of Mucopolysaccharidoses

    Mihriban Tijen Tanyalcin MD, PhD


    Full Text Available The purpose of this communication is to indicate a simple and rapid method with a small volume of urine sample to detect urine glycosaminoglycan (GAG and serve as a screening procedure for mucopolysaccharidoses (MPSs. Total GAG measurement for patients with MPS disorders is considered to be the first step in diagnosis of those heterogeneous group of lysosomal storage disorders presenting clinical phenotype. In this study, modified 9-dimethylmethylene blue method is used for total GAG measurement. Following GAG quantitation, the procedure described here allows GAG isolation from a very a small volume of urine sample and subjected to high-resolution GAG electrophoresis, which can be easily performed in routine clinical diagnostic laboratories. Glycosaminoglycan precipitation is a modified method based on total GAG concentration in the urine. For optimized isolation of total GAG for electrophoresis, instead of considering the urine creatinine concentration, 300 μg/mL GAG containing urine is considered to be the target concentration for the best precipitation with 1000 μL cetylpyridinium chloride (CPC/citrate buffer. Glycosaminoglycan concentration-based precipitation of urine with CPC allows the laboratory to be able to work with a small volume of urine sample by keeping the precipitating ratio with CPC constant for samples that contain GAG less than 300 μg/mL. Based on the effect of cold buffer using low voltage, GAGs high-resolution electrophoresis banding patterns described here enable a clear separation of keratan sulfate from chondroitin sulfate as well as dermatan sulfate (DS1 and DS2 and heparan sulfate. By this procedure, GAG patterns are more clear, easily identified, and provide a guide for the enzyme analysis deficient in the MPS disorders.

  4. 2D electrophoresis-based expression proteomics: a microbiologist's perspective.

    Sá-Correia, Isabel; Teixeira, Miguel C


    Quantitative proteomics based on 2D electrophoresis (2-DE) coupled with peptide mass fingerprinting is still one of the most widely used quantitative proteomics approaches in microbiology research. Our view on the exploitation of this global expression analysis technique and its contribution and potential to push forward the field of molecular microbial physiology towards a molecular systems microbiology perspective is discussed in this article. The advances registered in 2-DE-based quantitative proteomic analysis leading to increased protein resolution, sensitivity and accuracy, and the promising use of 2-DE to gain insights into post-translational modifications at a proteome-wide level (considering all the proteins/protein forms expressed by the genome) are focused on. Given the progress made in this field, it is foreseen that the 2-DE-based approach to quantitative proteomics will continue to be a fundamental tool for microbiologists working at a genome-wide scale. Guidelines are also provided for the exploitation of expression proteomics data, based on useful computational tools, and for the integration of these data with other genome-wide expression information. The advantages and limitations of a complete 2-DE-based expression proteomics analysis, envisaging the quantification of the global changes occurring in the proteome of a given cell depending on environmental or genetic manipulations, are discussed from the microbiologist's perspective. Particular focus is given to the emerging field of toxicoproteomics, a new systems toxicity approach that offers a powerful tool to directly monitor the earliest stages of the toxicological response by identifying critical proteins and pathways that are affected by, and respond to, a chemical stress. The experimental design and the bioinformatics analysis of data used in our laboratory to gain mechanistic insights through expression proteomics into the responses of the eukaryotic model Saccharomyces cerevisiae or of

  5. Quantification of Carbohydrates in Grape Tissues Using Capillary Zone Electrophoresis.

    Zhao, Lu; Chanon, Ann M; Chattopadhyay, Nabanita; Dami, Imed E; Blakeslee, Joshua J


    Soluble sugars play an important role in freezing tolerance in both herbaceous and woody plants, functioning in both the reduction of freezing-induced dehydration and the cryoprotection of cellular constituents. The quantification of soluble sugars in plant tissues is, therefore, essential in understanding freezing tolerance. While a number of analytical techniques and methods have been used to quantify sugars, most of these are expensive and time-consuming due to complex sample preparation procedures which require the derivatization of the carbohydrates being analyzed. Analysis of soluble sugars using capillary zone electrophoresis (CZE) under alkaline conditions with direct UV detection has previously been used to quantify simple sugars in fruit juices. However, it was unclear whether CZE-based methods could be successfully used to quantify the broader range of sugars present in complex plant extracts. Here, we present the development of an optimized CZE method capable of separating and quantifying mono-, di-, and tri-saccharides isolated from plant tissues. This optimized CZE method employs a column electrolyte buffer containing 130 mM NaOH, pH 13.0, creating a current of 185 μA when a separation voltage of 10 kV is employed. The optimized CZE method provides limits-of-detection (an average of 1.5 ng/μL) for individual carbohydrates comparable or superior to those obtained using gas chromatography-mass spectrometry, and allows resolution of non-structural sugars and cell wall components (structural sugars). The optimized CZE method was successfully used to quantify sugars from grape leaves and buds, and is a robust tool for the quantification of plant sugars found in vegetative and woody tissues. The increased analytical efficiency of this CZE method makes it ideal for use in high-throughput metabolomics studies designed to quantify plant sugars.

  6. Free zone electrophoresis simulation of static column electrophoresis in microgravity on shuttle flight STS-3

    Todd, P. W.; Hjerten, S.


    Experiments were designed to replicate, as closely as possible in 1-G, the conditions of the STS-3 red blood cell (RBC) experiments. Free zone electrophoresis was the method of choice, since it minimizes the role of gravity in cell migration. The physical conditions of the STS-3 experiments were used, and human and rabbit RBC's fixed by the same method were the test particles. The effects of cell concentration, electroosmotic mobility, and sample composition were tested in order to seek explanations for the STS-3 results and to provide data on cell concentration effects for future zero-G separation on the continuous-flow zero-G electrophoretics separator.

  7. Removal of interfering substances in samples prepared for two-dimensional (2-D) electrophoresis.

    Berkelman, Tom


    Biological samples may contain contaminants that interfere with analysis by two-dimensional (2-D) electrophoresis. Lysates or biological fluids are complex mixtures that contain a wide variety of nonprotein substances in addition to the proteins to be analyzed. These substances often interfere with the resolution of the electrophoretic separation or the visualization of the result. Macromolecules (e.g., polysaccharides and DNA) can interfere with electrophoretic separation by clogging gel pores. Small ionic molecules can impair isoelectric focusing (IEF) separation by rendering the sample too conductive. Other substances (e.g., phenolics and lipids) can bind to proteins, influencing their electrophoretic properties or solubility. In many cases, measures to remove interfering substances can result in significantly clearer 2-D patterns with more visible spots and better resolution. It should be borne in mind, however, that analysis of samples by 2-D electrophoresis is usually most successful and informative when performed with minimally processed samples, so it is important that any steps taken to remove interfering substance be appropriate to the sample and only performed when necessary. Procedures for the removal of interfering substances therefore represent a compromise between removing nonprotein contaminants, and minimizing interference with the integrity and relative abundances of the sample proteins. This chapter presents a number of illustrative examples of optimized sample preparation methods in which specific interfering substances are removed by a variety of different strategies.

  8. Plasma protein fractions in healthy blood donors quantitated by an automated multicapillary electrophoresis system.

    Larsson, Anders; Hansson, Lars-Olof


    During the last decade, capillary electrophoresis (CE) has emerged as an important alternative to traditional analysis of serum and plasma proteins by agarose or celluloseacetate electrophoresis. CE analysis of plasma proteins can now be fully automated and also includes bar-code identification of samples, preseparation steps, and direct post-separation quantitation of individual peaks, which permits short assay times and high throughput. For laboratory work, it is important to have reference values from healthy individuals. Therefore, plasma samples from 156 healthy blood donors (79 females and 77 males) have been analyzed with the Capillarys instrument and the new high resolution buffer, which yields higher resolution than the beta1-beta2+ buffer. Albumin concentrations in samples are measured using nephelometry in order to assign protein concentrations to each peak. The 2.5 and 97.5 percentiles for both the percentages of different peaks and the protein concentrations in the peaks are calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. The Capillarys instrument is a reliable system for plasma protein analysis, combining advantages of full automation with high analytical performances and throughput.

  9. Applications of capillary electrophoresis with chemiluminescence detection in clinical, environmental and food analysis. A review

    Lara, Francisco J.; Airado-Rodríguez, Diego; Moreno-González, David; Huertas-Pérez, José F.; García-Campaña, Ana M., E-mail:


    This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2′-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015. - Highlights: • An up-to-date critical review about the evolution of CE-CL is presented. • Tris(2,2′-bipyridine)ruthenium(II) and luminol as the most used CL systems. • Instrumental designs and strategies for improving resolution and sensitivity. • Applications in clinical, pharmaceutical, environmental and food analysis.

  10. Effect of polyamines on the separation of ovalbumin glycoforms by capillary electrophoresis.

    Legaz, M E; Pedrosa, M M


    The successful separation of ovalbumin (M(r) 45,000; pI 4.7) glycoforms by capillary electrophoresis in an uncoated fused-silica capillary with different buffer additives is reported. The optimum conditions for obtaining the resolution of glycoforms were 25 mM borate (pH 9.0) containing 0.87 mM spermidine or 0.14 mM spermine. The effects of different concentrations of putrescine, cadaverine, spermidine, spermine and some monoamines or diamines are compared in terms of selectivity factors of ovalbumin peaks. Addition of sodium dodecyl sulfate at a concentration below the critical micelle concentration increased the resolution between the three main peaks of ovalbumin but did not permit their microheterogeneity to be expressed.

  11. Use of electrophoresis and immunoelectrophoresis in taxonomic and pollution studies

    Menezes, M.R.; Qasim, S.Z.

    Studies were conducted on the electrophoresis of blood serum and eye lens proteins of 5 fishes and immunoelectrophoresis of the soluble lens proteins of 10 fishes. The effects of a toxic pollutant (mercury) on the electrophoretic patterns...

  12. Affinity capillary electrophoresis: the theory of electromigration.

    Dubský, Pavel; Dvořák, Martin; Ansorge, Martin


    We focus on the state-of-the-art theory of electromigration under single and multiple complexation equilibrium. Only 1:1 complexation stoichiometry is discussed because of its unique status in the field of affinity capillary electrophoresis (ACE). First, we summarize the formulas for the effective mobility in various ACE systems as they appeared since the pioneering days in 1992 up to the most recent theories till 2015. Disturbing phenomena that do not alter the mobility of the analyte directly but cause an unexpected peak broadening have been studied only recently and are also discussed in this paper. Second, we turn our attention to the viscosity effects in ACE. Change in the background electrolyte viscosity is unavoidable in ACE but numerous observations scattered throughout the literature have not been reviewed previously. This leads to an uncritical employment of correction factors that may or may not be appropriate in practice. Finally, we consider the ionic strength effects in ACE, too. Limitations of the current theories are also discussed and the tasks identified where open problems still prevail. Graphical Abstract A weak base (A) undergoes an acidic-basic equilibria (in blue) and migrates with an electrophoretic mobility of [Formula: see text]. Simultaneously, it interacts with a selector (sel) while the analyte-selector complex migrates with an electrophoretic mobility of [Formula: see text]. The strength of the interaction (in orange) is governed by the binding constant, K A , and the concentration of the selector, c sel . This all gives the analyte an effective mobility of [Formula: see text] and moves it out of the zero position (EOF; right top insert). The interaction of the positively charged analyte with the neutral selector slows down the analyte with increasing selector concentration (right bottom insert).

  13. Nonlinear electrophoresis of ideally polarizable particles

    Figliuzzi, B.; Chan, W. H. R.; Moran, J. L.; Buie, C. R.


    We focus in this paper on the nonlinear electrophoresis of ideally polarizable particles. At high applied voltages, significant ionic exchange occurs between the electric double layer, which surrounds the particle, and the bulk solution. In addition, steric effects due to the finite size of ions drastically modify the electric potential distribution in the electric double layer. In this situation, the velocity field, the electric potential, and the ionic concentration in the immediate vicinity of the particle are described by a complicated set of coupled nonlinear partial differential equations. In the general case, these equations must be solved numerically. In this study, we rely on a numerical approach to determine the electric potential, the ionic concentration, and the velocity field in the bulk solution surrounding the particle. The numerical simulations rely on a pseudo-spectral method which was used successfully by Chu and Bazant [J. Colloid Interface Sci. 315(1), 319-329 (2007)] to determine the electric potential and the ionic concentration around an ideally polarizable metallic sphere. Our numerical simulations also incorporate the steric model developed by Kilic et al. [Phys. Rev. E 75, 021502 (2007)] to account for crowding effects in the electric double layer, advective transport, and for the presence of a body force in the bulk electrolyte. The simulations demonstrate that surface conduction significantly decreases the electrophoretic mobility of polarizable particles at high zeta potential and at high applied electric field. Advective transport in the electric double layer and in the bulk solution is also shown to significantly impact surface conduction.

  14. Method for analysing glycoprotein isoforms by capillary electrophoresis

    Frutos, Mercedes de; Díez-Masa, José Carlos; Morales-Cid, Gabriel


    [EN] The present invention relates to a new method for the purification, concentration, separation and determination of the isoforms of alpha-1-acid glycoprotein (AGP) in human blood serum samples using capillary electrophoresis. The new method is based on the immunocapture and preconcentration of the sample within the separation capillary by using an immunoadsorbent phase magnetically immobilized within the electrophoresis capillary and the subsequent desorption and separation of the glycopr...

  15. Pulsed field gel electrophoresis on frozen tumour tissue sections.

    Boultwood, J; Kaklamanis, L.; Gatter, K C; Wainscoat, J S


    The application of pulsed field gel electrophoresis (PFGE) to the molecular genetic analysis of solid tumours has been restricted by the requirement for whole single cells as a DNA source. A simple technique which allows for the direct analysis of histologically characterised solid tumour material by pulsed field gel electrophoresis was developed. Single frozen tissue sections obtained from colonic carcinoma specimens were embedded without further manipulation in molten, low melting temperatu...

  16. Monitoring of enzymatic reactions using capillary electrophoresis with conductivity detection


    Capillary electrophoresis combined with contactless conductivity detection allows to separate and detect the ionic species, which are neither UV absorbing nor fluorescent. This thesis focuses on the applications of this method on enzymatic reactions in different analytical tasks. First, the non-ionic species ethanol, glucose, ethyl acetate and ethyl butyrate were made accessible for analysis by capillary electrophoresis via charged products or byproducts obtained in enzymati...

  17. Inkjet injection of DNA droplets for microchannel array electrophoresis.

    Yasui, Takao; Inoue, Yosuke; Naito, Toyohiro; Okamoto, Yukihiro; Kaji, Noritada; Tokeshi, Manabu; Baba, Yoshinobu


    We demonstrated DNA droplets could be injected with an inkjet injector for microchannel array electrophoresis and attained high throughput analysis of biomolecules. This injection method greatly reduced both analysis time and sample amount, compared with a conventional microchip electrophoresis method, and allowed high parallelization of a microchannel array on a small substrate. Since we do not need to use complicated electric programs or microchannel design, our injection method should facilitate omics analyses and contribute to high performance clinical assays.

  18. Diced electrophoresis gel assay for screening enzymes with specified activities.

    Komatsu, Toru; Hanaoka, Kenjiro; Adibekian, Alexander; Yoshioka, Kentaro; Terai, Takuya; Ueno, Tasuku; Kawaguchi, Mitsuyasu; Cravatt, Benjamin F; Nagano, Tetsuo


    We have established the diced electrophoresis gel (DEG) assay as a proteome-wide screening tool to identify enzymes with activities of interest using turnover-based fluorescent substrates. The method utilizes the combination of native polyacrylamide gel electrophoresis (PAGE) with a multiwell-plate-based fluorometric assay to find protein spots with the specified activity. By developing fluorescent substrates that mimic the structure of neutrophil chemoattractants, we could identify enzymes involved in metabolic inactivation of the chemoattractants.

  19. Pulsed-field gel electrophoresis of bacterial chromosomes.

    Mawer, Julia S P; Leach, David R F


    The separation of fragments of DNA by agarose gel electrophoresis is integral to laboratory life. Nevertheless, standard agarose gel electrophoresis cannot resolve fragments bigger than 50 kb. Pulsed-field gel electrophoresis is a technique that has been developed to overcome the limitations of standard agarose gel electrophoresis. Entire linear eukaryotic chromosomes, or large fragments of a chromosome that have been generated by the action of rare-cutting restriction endonucleases, can be separated using this technique. As a result, pulsed-field gel electrophoresis has many applications, from karyotype analysis of microbial genomes, to the analysis of chromosomal strand breaks and their repair intermediates, to the study of DNA replication and the identification of origins of replication. This chapter presents a detailed protocol for the preparation of Escherichia coli chromosomal DNA that has been embedded in agarose plugs, digested with the rare-cutting endonuclease NotI, and separated by contour-clamped homogeneous field electrophoresis. The principles in this protocol can be applied to the separation of all fragments of DNA whose size range is between 40 kb and 1 Mb.

  20. Determination of amino acid compositions and NH2-terminal sequences of peptides electroblotted onto PVDF membranes from tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis

    Ploug, M; Jensen, A L; Barkholt, V.


    The combination of high-resolution Tricine-Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (H. Schägger and G. von Jagow (1987) Anal. Biochem. 166, 368-379) and electroblotting onto polyvinylidene difluoride (PVDF) membranes represents a powerful technique for the isolation of small...... amounts of peptides and protein fragments (Mr 1000-20,000) in a suitable form for amino acid sequencing, directly on the blotting membrane. Conditions for electrophoresis and electroblotting were optimized with respect to high transfer yield and suitability for both amino acid analysis and sequence...

  1. Major proteins in normal human lymphocyte subpopulations separated by fluorescence-activated cell sorting and analyzed by two-dimensional gel electrophoresis

    Madsen, P S; Hokland, M; Ellegaard, J


    We have compared the overall patterns of protein synthesis of normal human lymphocyte subpopulations taken from five volunteers using high resolution two-dimensional gel electrophoresis. The lymphocytes were isolated using density gradient centrifugation, labeled with subtype-specific Mo......Abs, and separated to a high degree of homogeneity by FACS into CD4+ helper T cells, CD8+ suppressor T cells, CD20+ B cells, and N901 (NHK-1)+ NK cells. The four lymphocyte subpopulations were labeled with [35S]methionine for 14 hr, solubilized in lysis buffer, and analyzed by two-dimensional gel electrophoresis...

  2. Simultaneous detection of 19 K-ras mutations by free-solution conjugate electrophoresis of ligase detection reaction products on glass microchips.

    Albrecht, Jennifer Coyne; Kotani, Akira; Lin, Jennifer S; Soper, Steven A; Barron, Annelise E


    We demonstrate here the power and flexibility of free-solution conjugate electrophoresis (FSCE) as a method of separating DNA fragments by electrophoresis with no sieving polymer network. Previous work introduced the coupling of FSCE with ligase detection reaction (LDR) to detect point mutations, even at low abundance compared to the wild-type DNA. Here, four large drag-tags are used to achieve free-solution electrophoretic separation of 19 LDR products ranging in size from 42 to 66 nt that correspond to mutations in the K-ras oncogene. LDR-FSCE enabled electrophoretic resolution of these 19 LDR-FSCE products by CE in 13.5 min (E = 310 V/cm) and by microchip electrophoresis in 140 s (E = 350 V/cm). The power of FSCE is demonstrated in the unique characteristic of free-solution separations where the separation resolution is constant no matter the electric field strength. By microchip electrophoresis, the electric field was increased to the maximum of the power supply (E = 700 V/cm), and the 19 LDR-FSCE products were separated in less than 70 s with almost identical resolution to the separation at E = 350 V/cm. These results will aid the goal of screening K-ras mutations on integrated "sample-in/answer-out" devices with amplification, LDR, and detection all on one platform.

  3. A multi-channel gel electrophoresis and continuous fraction collection apparatus for high throughput protein separation and characterization

    Choi, Megan; Nordmeyer, Robert A.; Cornell, Earl; Dong, Ming; Biggin, Mark D.; Jin, Jian


    To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A Counter Free-Flow elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high-resolution separation of a complex protein mixture can be achieved on this system using SDS-PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48-96 fractions over a mass range of 10-150 kDa; sample recovery rates were 50percent or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 L/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 g per channel and reduced resolution.

  4. A multichannel gel electrophoresis and continuous fraction collection apparatus for high-throughput protein separation and characterization.

    Choi, Megan; Nordmeyer, Robert A; Cornell, Earl; Dong, Ming; Biggin, Mark D; Jin, Jian


    To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A "Counter Free-Flow" elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high-resolution separation of a complex protein mixture can be achieved on this system using SDS-PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48-96 fractions over a mass range of approximately 10-150 kDa; sample recovery rates were 50% or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 microL/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 microg per channel and reduced resolution.

  5. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M


    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation.

  6. Resolution propositions; Proposition de resolution



    To put a resolution to the meeting in relation with the use of weapons made of depleted uranium is the purpose of this text. The situation of the use of depleted uranium by France during the Gulf war and other recent conflicts will be established. This resolution will give the most strict recommendations face to the eventual sanitary and environmental risks in the use of these kind of weapons. (N.C.)

  7. Review of electrophoresis and BioMEMS in 2007: American Electrophoresis Society 24th Annual Meeting.

    Minerick, Adrienne R; Ugaz, Victor M; Murthy, Shashi K; Posner, Jonathan D


    Researchers came together for the 24th Annual Meeting of the American Electrophoresis Society (AES), which was held November 4-9, 2007, at the Salt Palace Convention Center in Salt Lake City, UT, U.S.A. The Annual AES meeting is held in conjunction with the annual meeting of the American Institute of Chemical Engineers (AIChE). This year's meeting had a significant emphasis on theoretical and experimental advances in Biological Micro Electro Mechanical Systems (BioMEMS), electrokinetics, and proteomics technologies. A total of 15 sessions were held, within which 71 presentations and 18 posters were discussed. This review provides a brief sampling of the exciting research presented at the conference.

  8. Electrophoresis: the march of pennies, the march of dimes.

    Righetti, Pier Giorgio


    The present review encompasses ca. 65 years of history of developments in electrokinetic separations, taking as a starting point the year 1937, i.e. the official launching of Tiselius' moving boundary electrophoresis (MBE). The 1950s have been particularly rich in introducing novel methodologies in zone electrophoresis (ZE), thus bringing about the decline of MBE. Among them of extraordinary importance was the development of electrophoresis on agar gels coupled to immuno-diffusion at right angles, which brought a big revolution not only in biochemistry but also in clinical chemistry. Also the by now forgotten paper electrophoresis was a landmark in separation science, in that it implemented, in its "fingerprinting" version, the first genuine two-dimensional (2D) map, coupling orthogonally a charge to a hydrophobic scale separation, while permitting for the first time the detection of spot mutations, i.e. single amino acid replacements in a polypeptide chain, that paved the way to modern genetic analysis. Equally important was the introduction of starch-block electrophoresis, that brought about the notion of sieving and the first discontinuous buffers, refined, in the 1960s, by Ornstein and Davies with their classical papers combining multiphasic buffer systems to polyacrylamide gels, that went down to history as disc-electrophoresis. The 1960s also contributed with two fundamental techniques, isoelectric focusing (IEF) and sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) that permitted to discriminate proteins solely on the basis of surface charge and molecular mass, respectively. The 1970s gave other fundamental contributions, such as isotachophoresis, the first example of a fully instrumental approach to electrophoresis, both in its analytical and preparative version (Tachophor and Tachofrac), 2D maps combining IEF to SDS-PAGE at right angles and silver staining techniques, that incremented sensitivity by 3 orders of magnitude. The 1980s

  9. Ligase detection reaction for the analysis of point mutations using free-solution conjugate electrophoresis in a polymer microfluidic device.

    Sinville, Rondedrick; Coyne, Jennifer; Meagher, Robert J; Cheng, Yu-Wei; Barany, Francis; Barron, Annelise; Soper, Steven A


    We have developed a new method for the analysis of low abundant point mutations in genomic DNA using a combination of an allele-specific ligase detection reaction (LDR) with free-solution conjugate electrophoresis (FSCE) to generate and analyze the genetic products. FSCE eliminates the need for a polymer sieving matrix by conjugating chemically synthesized polyamide "drag-tags" onto the LDR primers. The additional drag of the charge-neutral drag-tag breaks the linear scaling of the charge-to-friction ratio of DNA and enables size-based separations of DNA in free solution using electrophoresis with no sieving matrix. We successfully demonstrate the conjugation of polyamide drag-tags onto a set of four LDR primers designed to probe the K-ras oncogene for mutations highly associated with colorectal cancer, the simultaneous generation of fluorescently labeled LDR/drag-tag conjugate (LDR-dt) products in a multiplexed, single-tube format with mutant:WT ratios as low as 1:100, respectively, and the single-base, high-resolution separation of all four LDR-dt products. Separations were conducted in free solution with no polymer network using both a commercial capillary array electrophoresis (CAE) system and a PMMA microchip replicated via hot-embossing with only a Tris-based running buffer containing additives to suppress the EOF. Typical analysis times for LDR-dt were 11 min using the CAE system and as low as 85 s for the PMMA microchips. With resolution comparable to traditional gel-based CAE, FSCE along with microchip electrophoresis decreased the separation time by more than a factor of 40.

  10. Rheological and mechanical behavior of polyacrylamide hydrogels chemically crosslinked with allyl agarose for two-dimensional gel electrophoresis.

    Suriano, R; Griffini, G; Chiari, M; Levi, M; Turri, S


    Two-dimensional (2-D) gel electrophoresis currently represents one of the most standard techniques for protein separation. In addition to the most commonly employed polyacrylamide crosslinked hydrogels, acrylamide-agarose copolymers have been proposed as promising systems for separation matrices in 2-D electrophoresis, because of the good resolution of both high and low molecular mass proteins made possible by careful control and optimization of the hydrogel pore structure. As a matter of fact, a thorough understanding of the nature of the hydrogel pore structure as well as of the parameters by which it is influenced is crucial for the design of hydrogel systems with optimal sieving properties. In this work, a series of acrylamide-based hydrogels covalently crosslinked with different concentrations of allyl agarose (0.2-1%) is prepared and characterized by creep-recovery measurements, dynamic rheology and tensile tests, in the attempt to gain a clearer understanding of structure-property relationships in crosslinked polyacrylamide-based hydrogels. The rheological and mechanical properties of crosslinked acrylamide-agarose hydrogels are found to be greatly affected by crosslinker concentration. Dynamic rheological tests show that hydrogels with a percentage of allyl agarose between 0.2% and 0.6% have a low density of elastically effective crosslinks, explaining the good separation of high molecular mass proteins in 2-D gel electrophoresis. Over the same range of crosslinker concentration, creep-recovery measurements reveal the presence of non-permanent crosslinks in the hydrogel network that justifies the good resolution of low molecular mass proteins as well. In tensile tests, the hydrogel crosslinked with 0.4% of allyl agarose exhibits the best results in terms of mechanical strength and toughness. Our results show how the control of the viscoelastic and the mechanical properties of these materials allow the design of mechanically stable hydrogels with improved

  11. Conflict Resolution

    and shift the focus more to the social impact of growth ana away from growth .... Perspectives on, and approaches towards, conflict and conflict resolution .... transformation, and changes in values and ethical approaches (such as nepotism ... education, life expectancy, employment, childbirth survival and similar indica-.

  12. Dynamic computer simulations of electrophoresis: three decades of active research.

    Thormann, Wolfgang; Caslavska, Jitka; Breadmore, Michael C; Mosher, Richard A


    Dynamic models for electrophoresis are based upon model equations derived from the transport concepts in solution together with user-inputted conditions. They are able to predict theoretically the movement of ions and are as such the most versatile tool to explore the fundamentals of electrokinetic separations. Since its inception three decades ago, the state of dynamic computer simulation software and its use has progressed significantly and Electrophoresis played a pivotal role in that endeavor as a large proportion of the fundamental and application papers were published in this periodical. Software is available that simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. This has been employed to show the detailed mechanisms of many of the fundamental phenomena that occur in electrophoretic separations. Dynamic electrophoretic simulations are relevant for separations on any scale and instrumental format, including free-fluid preparative, gel, capillary and chip electrophoresis. This review includes a historical overview, a survey of current simulators, simulation examples and a discussion of the applications and achievements of dynamic simulation.

  13. Hydrodynamic injection on electrophoresis microchips using an electronic micropipette.

    Gabriel, Ellen F M; Dos Santos, Rodrigo A; Lobo-Júnior, Eulício O; Rezende, Kariolanda C A; Coltro, Wendell K T


    Here we report for the first time the use of an electronic micropipette as hydrodynamic (HD) injector for microchip electrophoresis (ME) devices. The micropipette was directly coupled to a PDMS device, which had been fabricated in a simple cross format with two auxiliary channels for sample volume splitting. Sample flow during the injection procedure was controlled in automatic dispenser mode using a volume of 0.6µL. Channel width and device configuration were optimized and the best results were achieved using a simple cross layout containing two auxiliary channels with 300µm width for sample splitting. The performance of the HD injector was evaluated using a model mixture of high-mobility cationic species. The results obtained were compared to the data obtained via electrokinetic (EK) injection. Overall, the HD provided better analytical performance in terms of resolution and injection-to-injection repeatability. The relative standard deviation (RSD) values for peak intensities were lower than 5% (n=10) when the micropipette was employed. In comparison with EK injection, the use of the proposed HD injector revealed an unbiased profile for a mixture containing K(+) and Li(+)(300 µmol L(-1) each) over various buffer concentrations. For EK injection, the peak areas decreased from 2.92 ± 0.20-0.72 ± 0.14Vs for K(+) and from 1.30 ± 0.10-0.38 ± 0.10Vs for Li(+) when the running buffer increased from 20 to 50mmolL(-1). For HD injection, the peak areas for K(+) and Li(+) exhibited average values of 2.48±0.07 and 2.10±0.06Vs, respectively. The limits of detection (LDs) for K(+), Na(+) and Li(+) ranged from 18 to 23µmolL(-1). HD injection through an electronic micropipette allows to automatically dispense a bias-free amount of sample inside microchannels with acceptable repeatability. The proposed approach also exhibited instrumental simplicity, portability and minimal microfabrication requirements.

  14. Strain identification in Rhizobium by starch gel electrophoresis of isoenzymes

    Engvild, Kjeld Christensen; Nielsen, G.


    Sonieated extracts of rhizobia, especiaUy Rhizobium leguminosarum from pea and vetch, were run in horizontal starch gel electrophoresis in the cold. The rhizobia were grown on agar on a slime suppressing substrate of tryptone-yeast extract-CaCl2 with small amounts of mannitol, sorbitol and arabin......Sonieated extracts of rhizobia, especiaUy Rhizobium leguminosarum from pea and vetch, were run in horizontal starch gel electrophoresis in the cold. The rhizobia were grown on agar on a slime suppressing substrate of tryptone-yeast extract-CaCl2 with small amounts of mannitol, sorbitol...... and arabinose and other sugars as enzyme inducers. After electrophoresis the gels were separated into several slabs by a gel cutter. Each slab was stained for a particular enzyme. Among numerous enzyme systems tested we found useful variation in esterases (EC, EC, 3-hydroxybutyrate...

  15. The separation of whale myoglobins with two-dimensional electrophoresis.

    Spicer, G S


    Five myoglobins (sperm whale, Sei whale, Hubbs' beaked whale, pilot whale, and Amazon River dolphin) were examined using two-dimensional electrophoresis. Previous reports indicated that none of these proteins could be separated by using denaturing (in the presence of 8-9 M urea) isoelectric focusing. This result is confirmed in the present study. However, all the proteins could be separated by using denaturing nonequilibrium pH-gradient electrophoresis in the first dimension. Additionally, all the myoglobins have characteristic mobilities in the second dimension (sodium dodecyl sulfate), but these mobilities do not correspond to the molecular weights of the proteins. We conclude that two-dimensional electrophoresis can be more sensitive to differences in primary protein structure than previous studies indicate and that the assessment seems to be incorrect that this technique can separate only proteins that have a unit charge difference.

  16. 20 Years of Fatty Acid Analysis by Capillary Electrophoresis

    Marcone Augusto Leal de Oliveira


    Full Text Available A review taking into account the literature reports covering 20 years of fatty acid analysis by capillary electrophoresis is presented. This paper describes the evolution of fatty acid analysis using different CE modes such as capillary zone electrophoresis, non-aqueous capillary electrophoresis, micellar electrokinetic capillary chromatography and microemulsion electrokinetic chromatography employing different detection systems, such as ultraviolet-visible, capacitively coupled contactless conductivity, laser-induced fluorescence and mass spectrometry. In summary, the present review signals that CE seems to be an interesting analytical separation technique that is very useful for screening analysis or quantification of the usual fatty acids present in different matrices, offering short analysis times and a simple sample preparation step as inherent advantages in comparison with the classical methodology, making it a separation technique that is very attractive for quality control in industry and government agencies.

  17. Nonlinear electrophoresis in the presence of dielectric decrement

    Figliuzzi, B.; Chan, W. H. R.; Buie, C. R.; Moran, J. L.


    The nonlinear phenomena that occur in the electric double layer (EDL) that forms at charged surfaces strongly influence electrokinetic effects, including electro-osmosis and electrophoresis. In particular, saturation effects due to either dielectric decrement or ion crowding effects are of paramount importance. Dielectric decrement significantly influences the ionic concentration in the EDL at high ζ potential, leading to the formation of a condensed layer near the particle's surface. In this article, we present a model incorporating both steric effects due to the finite size of ions and dielectric decrement to describe the physics in the electric double layer. The model remains valid in both weakly and strongly nonlinear regimes, as long as the electric double layer remains in quasiequilibrium. We apply this model to the study of two archetypal problems in electrokinetics, namely the electrophoresis of particles with fixed surface charges and the electrophoresis of ideally polarizable particles.

  18. Electrophoresis for the analysis of heparin purity and quality.

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J


    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment.

  19. Distance regularized level set evolution in magnetic resonance image segmention based on bi-dimensional ensemble empirical mo de decomp osition%基于二维集合经验模式分解的距离正则化水平集磁共振图像分割∗

    范虹; 韦文瑾; 朱艳春


    针对现有磁共振(MR)图像分割算法大多直接在原图像上进行处理,分割效果受噪声影响较大的问题,本文引入二维集合经验模式分解(BEEMD)算法,提高距离正则化水平集(DRLSE)方法对MR图像的分割精度。算法中首先使用 BEEMD将待分割MR图像分解为多个二维固有模式函数(BIMF),通过对各BIMF赋予不同加权系数重构待分割图像,从而增强分割目标;然后在DRLSE的边界指示函数中添加部分BIMF分量,恢复因高斯平滑被模糊的目标轮廓,并使用DRLSE方法对重构图像进行分割。通过对仿真图像和临床MR图像分割验证,表明本文算法具有较高的分割精度和鲁棒性,能有效实现对临床MR图像的分割。%Original image is directly processed by the existing image segmentation algorithms, which is easily affected by noise. A bi-dimensional ensemble empirical mode decomposition (BEEMD) method is introduced to improve the accuracy of MR image segmentation by distance regularized level set (DRLSE) method. The BEEMD method is the extension of one-dimensional noise assisted data analysis from ensemble empirical mode decomposition (EEMD). The key points of BEEMD are as follows. four-neighborhood optimization is used to find extermum; three-spline interpolation is used to obtain the envelope;amplitude standard of added white noise is restricted;a certain time of integration is used to avoid modality aliasing problem. The main steps of the proposed method are as follows. Firstly, the MR image is decomposed into a number of two-dimensional intrinsic mode functions (BIMF) by BEEMD method;different weighting coefficients are endued to BIMF for image reconstruction to enhance the segmentation target. Secondly, part of BIMF components are added into edge indicator function of DRLSE to recover the blurring boundary caused by Gauss smooth operation. Then DRLSE is used to segment the reconstructed MR image. High accuracy and

  20. Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection

    Johnson, Alicia S.; Mehl, Benjamin T.; Martin, R. Scott


    In this work, a polystyrene (PS)-polydimethylsiloxane (PDMS) hybrid device was developed to enable the integration of cell culture with analysis by microchip electrophoresis and electrochemical detection. It is shown that this approach combines the fundamental advantages of PDMS devices (the ability to integrate pumps and valves) and PS devices (the ability to permanently embed fluidic tubing and electrodes). The embedded fused-silica capillary enables high temporal resolution measurements from off-chip cell culture dishes and the embedded electrodes provide close to real-time analysis of small molecule neurotransmitters. A novel surface treatment for improved (reversible) adhesion between PS and PDMS is described using a chlorotrimethylsilane stamping method. It is demonstrated that a Pd decoupler is efficient at handling the high current (and cathodic hydrogen production) resulting from use of high ionic strength buffers needed for cellular analysis; thus allowing an electrophoretic separation and in-channel detection. The separation of norepinephrine (NE) and dopamine (DA) in highly conductive biological buffers was optimized using a mixed surfactant system. This PS-PDMS hybrid device integrates multiple processes including continuous sampling from a cell culture dish, on-chip pump and valving technologies, microchip electrophoresis, and electrochemical detection to monitor neurotransmitter release from PC 12 cells. PMID:25663849

  1. Chiral separation of benzoporphyrin derivative mono- and diacids by laser induced fluorescence-capillary electrophoresis.

    Peng, Xuejun; Sternberg, Ethan; Dolphin, David


    A method for the separation of benzoporphyrin derivative mono- and diacid (BPDMA, BPDDA) enantiomers by laser induced fluorescence-capillary electrophoresis (LIF-CE) has been developed. By using 300 mM borate buffer, pH 9.2, 25 mM sodium cholate and 10% acetronitrile as electrolyte, +10 kV electrokinetic sampling injection of 2 s and an applied +20 kV voltage across the ends of a 37 cm capillary (30 cm to the detector, 50 microm ID), all six BPD stereoisomers were baseline-separated within 20 min. Formation constants, free electrophoretic and complexation mobilities with borate and cholate were determined based on dynamic complexation capillary electrophoresis theory. The BPD enantiomers can be quantitatively determined in the range of 10(-2)-10(-5) mg mL(-1). The correlation coefficients (r2) of the least-squares linear regression analysis of the BPD enantiomers are in the range of 0.9914-0.9997. Their limits of detection are 2.18-3.5 x 10(-3) mg mL(-1). The relative standard deviations for the separation were 2.90-4.64% (n = 10). In comparison with high-performance liquid chromatography (HPLC), CE has better resolution and efficiency. This separation method was successfully applied to the BPD enantiomers obtained from a matrix of bovine serum and from liposomally formulated material as well as from studies with rat, dog and human microsomes.

  2. Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry

    Baker, S. A.; Miller-Ihli, N. J.


    The determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS) was investigated. Both capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) modes of operation were studied. The optimal separation of four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5'-deoxyadenosylcobalamin) and a potentially harmful corrinoid analogue (cobinamide dicyanide) was obtained using CZE at a pH of 2.5. Both 20 mM phosphate and 20 mM formate buffers were used with success, although the formate buffer provided improved resolution. The CZE-ICP-MS method was used to quantify cyanocobalamin in a vitamin supplement and the analytical results were in good agreement (±5%) with values obtained by ICP-MS for total Co levels. The solution detection limits for cobalamins using CZE-ICP-MS were approximately 50 ng/ml. MEKC was found to be useful for the screening of vitamin preparations because it provided a rapid means of distinguishing cyanocobalamin (the form most commonly used in vitamin preparations) from free cobalt. The separation of free cobalt and cyanocobalamin using MEKC was achieved in less than 10 min.

  3. A Novel Universal Primer-Multiplex-PCR Method with Sequencing Gel Electrophoresis Analysis

    Huang, Kunlun; Zhang, Nan; Yuan, Yanfang; Shang, Ying; Luo, Yunbo


    In this study, a novel universal primer-multiplex-PCR (UP-M-PCR) method adding a universal primer (UP) in the multiplex PCR reaction system was described. A universal adapter was designed in the 5′-end of each specific primer pairs which matched with the specific DNA sequences for each template and also used as the universal primer (UP). PCR products were analyzed on sequencing gel electrophoresis (SGE) which had the advantage of exhibiting extraordinary resolution. This method overcame the disadvantages rooted deeply in conventional multiplex PCR such as complex manipulation, lower sensitivity, self-inhibition and amplification disparity resulting from different primers, and it got a high specificity and had a low detection limit of 0.1 ng for single kind of crops when screening the presence of genetically modified (GM) crops in mixture samples. The novel developed multiplex PCR assay with sequencing gel electrophoresis analysis will be useful in many fields, such as verifying the GM status of a sample irrespective of the crop and GM trait and so on. PMID:22272223

  4. Application of Two-Dimensional Electrophoresis in the Research of Retinal Proteins of Diabetic Rat

    Shangqing Liu; Yanyan Zhang; Xianyong Xie; Weiming Hu; Rong Cai; Jian Kang; Huijun Yang


    Diabetes mellitus (DM) is a chronic disease which is associated with numerous serious health complications such as diabetic retinopathy, and is the leading cause of new cases of blindness in adults at the age of 20-74 years old. The aim of the study was to establish and optimize a two-dimensional polyacrylamide gel electrophoresis (2-DE) technique for retina proteomics to improve the resolution and reproducibility, and to observe the proteomic changes of retinal tissues in diabetic and normal rats. Proteins were extracted from retinal tissues of normal and 8 weeks diabetic SD rats and used in two-dimensional electrophoresis. Various conditions of retina proteomic 2-DE were adjusted, optimized and protein spots of differential expression were obtained through analysis of 2-DE images with PDQuest software. By choosing appropriate sample amount, using pre-cast IPG dry strips (pH 5-8)and casting 12% equal gel, satisfactory 2-DE images of retina were obtained and a steady 2-DE technique was established. In this way, we found 36 spots in 2-DE gel of diabetic retinas that exhibited statistically significant variations, including up-regulation of 5 proteins in diabetic rat retinas, down-regulation of 23, and disappearance of 8, in comparison with normal tissues. The differences of protein expression were observed in retinas between diabetic and normal rats. Our established 2-DE technique of retina proteins could be effectively applied in proteomics of retina diseases.

  5. Cutting-edge capillary electrophoresis characterization of monoclonal antibodies and related products.

    Gahoual, Rabah; Beck, Alain; Leize-Wagner, Emmanuelle; François, Yannis-Nicolas


    Out of all categories, monoclonal antibodies (mAbs), biosimilar, antibody-drug conjugates (ADCs) and Fc-fusion proteins attract the most interest due to their strong therapeutic potency and specificity. Because of their intrinsic complexity due to a large number of micro-heterogeneities, there is a crucial need of analytical methods to provide comprehensive in-depth characterization of these molecules. CE presents some obvious benefits as high resolution separation and miniaturized format to be widely applied to the analysis of biopharmaceuticals. CE is an effective method for the separation of proteins at different levels. capillary gel electrophoresis (CGE), capillary isoelectric focusing (cIEF) and capillary zone electrophoresis (CZE) have been particularly relevant for the characterization of size and charge variants of intact and reduced mAbs, while CE-MS appears to be a promising analytical tool to assess the primary structure of mAbs and related products. This review will be dedicated to detail the current and state-of-the-art CE-based methods for the characterization of mAbs and related products.

  6. Analysis of inflammatory response in human plasma samples by an automated multicapillary electrophoresis system.

    Larsson, Anders; Hansson, Lars-Olof


    A new automated multicapillary zone electrophoresis instrument with a new high-resolution (HR) buffer (Capillarys with HR buffer) for analysis of human plasma proteins was evaluated. Albumin, alpha(1)-antitrypsin, alpha(1)-acid glycoprotein, haptoglobin, fibrinogen, immunoglobulin (Ig)A, IgG and IgM were determined nephelometrically in 200 patient plasma samples. The same samples were then analyzed on the Capillarys system (Sebia, Paris, France). The albumin concentration from the nephelometric determination was used for quantification of the individual peaks in the capillary electrophoresis (CE) electropherogram. There was strong linear correlation between the nephelometric and electrophoretic determination of alpha(1)-antitrypsin (R(2) = 0.906), alpha(1)-acid glycoprotein (R(2) =0.894) and haptoglobin (R(2) = 0.913). There was also good correlation between the two determinations of gamma-globulins (R(2) = 0.883), while the correlation was weaker for fibrinogen (R(2) = 0.377). The Capillarys instrument is a reliable system for plasma protein analysis, combining the advantages of full automation, good analytical performance and high throughput. The HR buffer in combination with albumin quantification allows the simultaneous quantification of inflammatory markers in plasma samples without the need for nephelometric determination of these proteins.

  7. Electrophoresis Profile of Total Peroxidases in Saliva and Sera of Patients with Different Oral Tumors.

    Hathama Razooki Hasan


    Full Text Available Total peroxidase system (EC 1.11.1.X activity is known to play a key role in a number of human diseases, where the activity of these species can be both beneficial & detrimental. In our previous work (submitted for publication a remarkable increase have been noticed in the activity of this system in saliva of patients with oral tumors (Oral Squamous Cell Carcinoma OSCC, & Oral Ossifying Fibroma, OF. The present project aimed to highlight the variations in the different forms of this system in saliva & serum samples among patients with above mentioned tumors, in comparison to that of corresponding healthy individuals, using the electrophoresis as the analytical tool. Salivary peroxidase gave faint bands with a poor separation when the analysis was carried out using basic PAGE electrohoresis while good clear bands, as well as better resolutions of these bands were obtained when acidic PAGE electrophoresis was used for the analysis. An additional band, moved further toward the anode, was observed to be present, as the electrozymogram indicated, in the saliva samples of the patients with malignant tumors (Squamous cell carcinoma. The results also showed that using benzidine, or o-dianisidine, as the substrate in staining of the polyacrylamide gels , in order to localize the bands that exhibit peroxidase activity, seems to be better than using 3, 3’, 5, 5’-Tetramethylbenzidine( TMBZ as the substrate for this purpose.

  8. Enhanced detergent extraction for analysis of membrane proteomes by two-dimensional gel electrophoresis

    Hsu Kimberly K


    Full Text Available Abstract Background The analysis of hydrophobic membrane proteins by two-dimensional gel electrophoresis has long been hampered by the concept of inherent difficulty due to solubility issues. We have optimized extraction protocols by varying the detergent composition of the solubilization buffer with a variety of commercially available non-ionic and zwitterionic detergents and detergent-like phospholipids. Results After initial analyses by one-dimensional SDS-PAGE, quantitative two-dimensional analyses of human erythrocyte membranes, mouse liver membranes, and mouse brain membranes, extracted with buffers that included the zwitterionic detergent MEGA 10 (decanoyl-N-methylglucamide and the zwitterionic lipid LPC (1-lauroyl lysophosphatidylcholine, showed selective improvement over extraction with the common 2-DE detergent CHAPS (3 [(3-cholamidopropyldimethylammonio]-1-propanesulfonate. Mixtures of the three detergents showed additive improvements in spot number, density, and resolution. Substantial improvements in the analysis of a brain membrane proteome were observed. Conclusion This study demonstrates that an optimized detergent mix, coupled with rigorous sample handling and electrophoretic protocols, enables simple and effective analysis of membrane proteomes using two-dimensional electrophoresis.

  9. Microplate array diagonal gel electrophoresis for cohort studies of microsatellite loci.

    Chen, Xiao-he; O'Dell, Sandra D; Day, Ian N M


    After PCR amplification, we have achieved precise sizing of trinucleotide and tetranucleotide microsatellite alleles on 96-well open-faced polyacrylamide microplate array diagonal gel electrophoresis (MADGE) gels: two tetranucleotide repeats, HUMTHOI (five alleles 248-263 bp) and DYS390 (eight alleles 200-228 bp), and DYS392, a trinucleotide repeat (eight alleles 210-231 bp). A gel matrix of Duracryl, a high mechanical strength polyacrylamide derivative, and appropriate ionic conditions provide the 1.3%-1.5% band resolution required. No end-labeling of primers is needed, as the sensitive Vistra Green intercalating dye is used for the visualization of bands. Co-run markers bracketing the PCR fragments ensure accurate sizing without inter-lane variability. Electrophoresis of multiple gels in a thermostatically controlled tank allows up to 1000 samples to be run in 90 min. Gel images were analyzed using a Fluorlmager 595 fluorescent scanning system, and alleles were identified using Phoretix software for band migration measurement and Microsoft Excel to compute fragment sizes. Estimated sizes were interpolated precisely to achieve accurate binning. Microsatellite-MADGE represents a utilitarian methodfor high-throughput genotyping in cohort studies, using standard laboratory equipment.

  10. Capillary Electrophoresis in the Analysis of Polyunsaturated Fatty Acids

    Gabriel Hancu


    Full Text Available The aim of this study to inventory the main electrophoretic methods for identification and quantitative determination of fatty acids from different biological matrices. Critical analysis of electrophoretic methods reported in the literature show that the determination of polyunsaturated fatty acids can be made by: capillary zone electrophoresis, micellar electrokinetic chromatography and microemulsion electrokinetic chromatography using different detection systems such as ultraviolet diode array detection, laser induced fluorescence or mass – spectrometry. Capillary electrophoresis is a fast, low-cost technique used for polyunsaturated fatty acids analysis although their determination is mostly based on gas chromatography.

  11. Fabrication technology of integrated fiber microfluidic electrophoresis chip

    LI MengChun


    The technology of PCB was used to fabricate the chip mould, and the microfluidic electrophoresis chip was fabricated with PDMS material. The fiber integrated on the chip was used as the transmission medium, so the light spot size was near the depth of microchannel. The detection sensitivity was improved, and the optical focusing system was spared. The fabrication process, sealing methods and structure characteristic of PDMS microfluidic electrophoresis chips were discussed. The experiment was achieved by using the fabricated chip to separate FITC fluorescein and FITC-labeled amino acid mixture reagent, and the feasibility of the chip was validated.

  12. Strain identification in Rhizobium by starch gel electrophoresis of isoenzymes

    Engvild, Kjeld Christensen; Nielsen, G.


    Sonieated extracts of rhizobia, especiaUy Rhizobium leguminosarum from pea and vetch, were run in horizontal starch gel electrophoresis in the cold. The rhizobia were grown on agar on a slime suppressing substrate of tryptone-yeast extract-CaCl2 with small amounts of mannitol, sorbitol...... and arabinose and other sugars as enzyme inducers. After electrophoresis the gels were separated into several slabs by a gel cutter. Each slab was stained for a particular enzyme. Among numerous enzyme systems tested we found useful variation in esterases (EC, EC, 3-hydroxybutyrate...

  13. Solar Flare Chromospheric Line Emission: Comparison Between IBIS High-resolution Observations and Radiative Hydrodynamic Simulations

    da Costa, Fatima Rubio; Petrosian, Vahé; Dalda, Alberto Sainz; Liu, Wei


    Solar flares involve impulsive energy release, which results in enhanced radiation in a broad spectral and at a wide height range. In particular, line emission from the chromosphere (lower atmosphere) can provide critical diagnostics of plasma heating processes. Thus, a direct comparison between high-resolution spectroscopic observations and advanced numerical modeling results can be extremely valuable, but has not been attempted so far. We present in this paper such a self-consistent investigation of an M3.0 flare observed by the Dunn Solar Telescope's (DST) Interferometric Bi-dimensional Spectrometer (IBIS) on 2011 September 24 that we have modeled with the radiative hydrodynamic code RADYN (Carlsson & Stein 1992, 1997; Abbett & Hawley 1999; Allred et al. 2005). We obtained images and spectra of the flaring region with IBIS in H$\\alpha$ 6563 \\AA\\ and Ca II 8542 \\AA, and with the Reuven Ramaty High Energy Solar Spectroscope Imager (RHESSI) in X-rays. The latter was used to infer the non-thermal elect...

  14. Determination of Magnolol and Honokiol by Non-aqueous Capillary Electrophoresis


    Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaqueous buffer on column efficiency and resolution, and the effect of acid additives on peak shapes were researched. The separation was conducted with a running buffer in a mixture of methanol/acetonitrile/formamide (volume ratio: 1: 2: 2), in which the concentrations of Tris, acetic acid, and water were 60 mmol/L, 0. 04 mmol/L and 5% (volume fration),respectively, and the pH * (apperent pH) of the running buffer was 8. 96. Magnolol and honokiol were separated on baseline within 20 min. The relative standard deviation of the analytes' concentrations in the sample is 1.32% for magnolol and 1.60% for honokiol, and the recoveries of the spiked sample are 98.4% for magnolol and 98.0% for honokiol, respectively.

  15. Fabrication of anti-protein-fouling poly(ethylene glycol) microfluidic chip electrophoresis by sandwich photolithography.

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Liu, Huwei; Yuan, Hua


    Microfluidic chip electrophoresis (MCE) is a powerful separation tool for biomacromolecule analysis. However, adsorption of biomacromolecules, particularly proteins onto microfluidic channels severely degrades the separation performance of MCE. In this paper, an anti-protein-fouling MCE was fabricated using a novel sandwich photolithography of poly(ethylene glycol) (PEG) prepolymers. Photopatterned microchannel with a minimum resolution of 10 μm was achieved. After equipped with a conventional online electrochemical detector, the device enabled baseline separation of bovine serum albumin, lysozyme (Lys), and cytochrome c (Cyt-c) in 53 s under a voltage of 200 V. Compared with a traditional polydimethylsiloxane MCE made by soft lithography, the PEG MCE made by the sandwich photolithography not only eliminated the need of a master mold and the additional modification process of the microchannel but also showed excellent anti-protein-fouling properties for protein separation.

  16. Development of a capillary electrophoresis method for the simultaneous determination of cephalosporins

    Hancu Gabriel


    Full Text Available A rapid and simple capillary electrophoresis method has been developed for the simultaneous determination of six extensively used cephalosporin antibiotics (cefaclor, cefadroxil, cefalexin, cefuroxim, ceftazidim, ceftriaxon. The determination of cephalosporins was performed at a pH 6.8, using a 25 mM phospate - 25 mM borate mixed buffer, + 25 kV voltage at a temperature of 25 °C. We achieved a baseline separation in approximately 10 minutes. The separation resolution was increased by addition of an anionic surfactant, 50 mM sodium dodecyl sulfate, to the buffer solution. The proposed separation was evaluated on the basis of detection and quantification limits, effective electrophoretic mobility and relative standard deviation for migration times and peak areas.

  17. Optimization of Large Gel 2D Electrophoresis for Proteomic Studies of Skeletal Muscle

    Reed, Patrick W.; Densmore, Allison; Bloch, Robert J.


    We describe improved methods for large format, 2-dimensional gel electrophoresis (2-DE) that improve protein solubility and recovery, minimize proteolysis, and reduce the loss of resolution due to contaminants and manipulations of the gels, and thus enhance quantitative analysis of protein spots. Key modifications are: (i) the use of 7M urea + 2 M thiourea, instead of 9M urea, in sample preparation and in the tops of the gel tubes; (ii) standardized deionization of all solutions containing urea with a mixed bed ion exchange resin and removal of urea from the electrode solutions; and (iii) use of a new gel tank and cooling device that eliminate the need to run two separating gels in the SDS dimension. These changes make 2D-GE analysis more reproducible and sensitive, with minimal artifacts. Application of this method to the soluble fraction of muscle tissues reliably resolves ~1800 protein spots in adult human skeletal muscle and over 2800 spots in myotubes. PMID:22589104

  18. Proteomic Analyses of Agkistrodon contortrix contortrix Venom Using 2D Electrophoresis and MS Techniques.

    Bocian, Aleksandra; Urbanik, Małgorzata; Hus, Konrad; Łyskowski, Andrzej; Petrilla, Vladimír; Andrejčáková, Zuzana; Petrillová, Monika; Legáth, Jaroslav


    Snake venom is a complex mixture of proteins and peptides which in the Viperidae is mainly hemotoxic. The diversity of these components causes the venom to be an extremely interesting object of study. Discovered components can be used in search for new pharmaceuticals used primarily in the treatment of diseases of the cardiovascular system. In order to determine the protein composition of the southern copperhead venom, we have used high resolution two dimensional electrophoresis and MALDI ToF/ToF MS-based identification. We have identified 10 groups of proteins present in the venom, of which phospholipase A₂ and metalloprotease and serine proteases constitute the largest groups. For the first time presence of 5'-nucleotidase in venom was found in this group of snakes. Three peptides present in the venom were also identified. Two of them as bradykinin-potentiating agents and one as an inhibitor.

  19. Proteomic Analyses of Agkistrodon contortrix contortrix Venom Using 2D Electrophoresis and MS Techniques

    Aleksandra Bocian


    Full Text Available Snake venom is a complex mixture of proteins and peptides which in the Viperidae is mainly hemotoxic. The diversity of these components causes the venom to be an extremely interesting object of study. Discovered components can be used in search for new pharmaceuticals used primarily in the treatment of diseases of the cardiovascular system. In order to determine the protein composition of the southern copperhead venom, we have used high resolution two dimensional electrophoresis and MALDI ToF/ToF MS-based identification. We have identified 10 groups of proteins present in the venom, of which phospholipase A2 and metalloprotease and serine proteases constitute the largest groups. For the first time presence of 5′-nucleotidase in venom was found in this group of snakes. Three peptides present in the venom were also identified. Two of them as bradykinin-potentiating agents and one as an inhibitor.

  20. Recent advances on the use of cyclodextrins in the chiral analysis of drugs by capillary electrophoresis.

    Saz, J M; Marina, M L


    The most recent advances on the use of cyclodextrins as chiral selectors in capillary electrophoresis for the enantioseparation of drugs are reviewed in this article. The types of cyclodextrins employed and the resolutions achieved are discussed. The use of dual chiral systems, modified capillaries, non-aqueous media or microfluidic devices is also included and the mechanisms for enantioseparation of drugs and the inversion of the enantiomer migration order are studied. The most relevant applications developed to carry out the quantitation of chiral drugs, to assess the enantiomeric purity of pharmaceutical formulations, to study their metabolism or to achieve criminalistic or forensic investigations are described. Articles published in the last six years (period from 2010 to 2015) are considered.

  1. Capillary electrophoresis as a tool for the characterization of pentosan nanoparticles.

    Abdel-Haq, Hanin; Bossù, Elena


    Because capillary zone electrophoresis (CZE) showed higher resolution for highly charged large carbohydrates and complex structures when compared to other chromatographic separation methods, it was chosen for the characterization of nanoparticles (NPs) of pentosan polysulfate (PPS). Thus, using the CZE technique, we developed a reliable, sensitive and rapid protocol that allowed the detection and characterization of PPS NPs. This protocol was able to determine the profile of both the NPs and the species of PPS entrapped into them, and to quantify free and bound PPS showing high reproducibility, acceptable accuracy and a good degree of precision. Moreover, it allowed the evaluation of the size and charge of the NPs. This protocol might be suitable for the characterization of other kinds of NPs also.

  2. Pulsed-field capillary electrophoresis: optimizing separation parameters with model mixtures of sulfonated polystyrenes.

    Sudor, J; Novotny, M V


    The electrophoretic transport of high molecular weight charged solutes, both flexible and stiff polymers, has been studied by capillary electrophoresis under constant-field and pulsed-field conditions. Sulfonated polystyrenes were used as model solutes in different entangled polymer solutions. First, changes of the end-to-end distance vectors of flexible polymers were examined through the mobility/potential-gradient curves. Under pulsed-field conditions, the influence of different pulse shapes, frequencies, and amplitudes of forward and backward pulses on the electrophoretic mobilities of model solutes was studied. Resolution of the mixture components was strongly affected by changes in frequency of both sine-wave and square-wave pulses. The experimental results obtained under pulse-field conditions are roughly in agreement with the existing theories of electrophoretic transport.

  3. Electrostatic interaction mechanism on the separation of phenols by non-aqueous capillary electrophoresis

    WEI WeiLi; YIN YongGuang; XIA ZhiNing; CHEN ZhiTao; LIU WeiQi


    The electrostatic interaction between additive and analyte is of great importance to non-aqueous capillary electrophoresis (NACE) separation. Three tetraalkylammonium bromides and acetonitrile were applied as additives and running solvent respectively. The effect of alkyl chain length and concentration of additive on electrostatic interactions was investigated by the separation of phenols. The separation ability was found to increase with decreasing alkyl chain length of the additive, and the resolution values were increased with increasing additive concentration. The separation was seriously deteriorated after a little amount of water was added in the running solution. Furthermore, the electrostatic interaction is strong under the conditions of low electron cloud density, weak steric hindrance and multi-interaction sites. Thus, the separation result can be predicted by theoretical analysis, which is helpful for the separation of other substances in NACE based on electrostatic interaction.

  4. Chiral separation of benzothiazole derivatives of amino acids using capillary zone electrophoresis.

    Nováková, Zuzana; Pejchal, Vladimír; Fischer, Jan; Česla, Petr


    A method for the separation of enantiomers of leucine and phenylalanine benzothiazole derivatives as potential antimicrobial agents was developed using capillary zone electrophoresis with a dual cyclodextrin (CD) system. The best resolution of enantiomers was achieved in 100 mmol/L phosphate background electrolyte (pH 3.5) with the dual CD system consisting of 10 mmol/L of β-CD with 10 mmol/L of 2-hydroxypropyl-β-cyclodextrin for leucine derivative and 10 mmol/L of 2-hydroxypropyl-γ-cyclodextrin for phenylalanine derivative, respectively. Under the optimal conditions, the highest enantioresolution of 1.25 was achieved in a noncoated-fused silica capillary at 17°C and 24 kV applied voltage.

  5. Typing dinucleotide repeat loci using microplate array diagonal gel electrophoresis: proof of principle.

    Rodríguez, Santiago; Chen, Xiao-He; Day, Ian N M


    Polymorphic dinucleotide repeat loci ('microsatellite markers') are found in varying abundance throughout the genomes of most organisms. They have been extensively used for genetic studies, but conventional techniques used for their genotyping require sophisticated equipment. Microplate array diagonal gel electrophoresis (MADGE) has previously been extended to economical high-throughput genotyping of trinucleotide and tetranucleotide microsatellite amplicons. However, the capability of this technique to resolve the alleles of dinucleotide repeat loci has not been explored previously. Here we show that a modified microsatellite-MADGE approach can provide sufficient resolution for dinucleotide repeat typing. This enables economical and convenient set up for analysis of single markers in many samples in parallel, suitable, for example, for population association studies.

  6. Strategy for non-target ionic analysis by capillary electrophoresis with ultraviolet detection.

    Sursyakova, Viktoria V; Burmakina, Galina V; Rubaylo, Anatoly I


    A strategy for non-target analysis of samples with unknown composition by capillary electrophoresis (CE) with ultraviolet (UV) detection is suggested. The strategy is based on the preliminary identification of analytes and further optimization of the conditions for their separation using the developed computational tool set ElphoSeparation. It is shown that, in order to record electrophoretic peaks with the mobilities from the maximum to minimum possible values, the positive and negative voltage polarity and hydrodynamic pressure should be used. To choose the optimal separation conditions, dynamic maps of electrophoretic separation (DMES) are suggested. DMES is a bar chart with theoretical resolutions of adjacent peaks presented in ascending order of the migration time. The resolution is calculated as the division of the difference of the effective electrophoretic mobilities of adjacent analytes by their average peak width in terms of electrophoretic mobility. The suggested strategy is tested by the example of the analysis of herbal medicine (Holosas) on the basis of rose hips. The approach should be used to analyze samples with not very complex composition, such as environmental water and precipitation samples, process liquors, some vegetable extracts, biological fluids, food, and other samples for the determination of widespread compounds capable of forming ionic species. For samples with complex composition, the approach used together with other techniques may produce advantageous information due to specificity of the method, particularly it can be useful for determination of compounds suffering from low volatility or thermal stability, and for analysis of samples with difficult matrices. Graphical Abstract The scheme of performing the non-target ionic analysis by capillary electrophoresis with ultraviolet detection.

  7. An effective placental cotyledons proteins extraction method for 2D gel electrophoresis.

    Tan, Niu J; Daim, Leona D J; Jamil, Amilia A M; Mohtarrudin, Norhafizah; Thilakavathy, Karuppiah


    Effective protein extraction is essential especially in producing a well-resolved proteome on 2D gels. A well-resolved placental cotyledon proteome, with good reproducibility, have allowed researchers to study the proteins underlying the physiology and pathophysiology of pregnancy. The aim of this study is to determine the best protein extraction protocol for the extraction of protein from placental cotyledons tissues for a two-dimensional gel electrophoresis (2D-GE). Based on widely used protein extraction strategies, 12 different extraction methodologies were carefully selected, which included one chemical extraction, two mechanical extraction coupled protein precipitations, and nine chemical extraction coupled protein precipitations. Extracted proteins were resolved in a one-dimensional gel electrophoresis and 2D-GE; then, it was compared with set criteria: extraction efficacy, protein resolution, reproducibility, and recovery efficiency. Our results revealed that a better profile was obtained by chemical extraction in comparison to mechanical extraction. We further compared chemical extraction coupled protein precipitation methodologies, where the DNase/lithium chloride-dense sucrose homogenization coupled dichloromethane-methanol precipitation (DNase/LiCl-DSH-D/MPE) method showed good protein extraction efficiency. This, however, was carried out with the best protein resolution and proteome reproducibility on 2D-gels. DNase/LiCl-DSH-D/MPE was efficient in the extraction of proteins from placental cotyledons tissues. In addition, this methodology could hypothetically allow the protein extraction of any tissue that contains highly abundant lipid and glycogen. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Unary resolution

    Aubert, Clément; Bagnol, Marc; Seiller, Thomas


    of the cut-elimination procedure of linear logic known as the geometry of interaction . This framework is restricted to terms (logic programs, rewriting rules) using only unary symbols, and this restriction is shown to be complete for polynomial time computation by encoding pushdown automata. Soundness w......We give a characterization of deterministic polynomial time computation based on an algebraic structure called the resolution semiring, whose elements can be understood as logic programs or sets of rewriting rules over first-order terms. This construction stems from an interactive interpretation...

  9. Methoxypropylamino β-cyclodextrin clicked AC regioisomer for enantioseparations in capillary electrophoresis

    Zhou, Jie; Wang, Yiying; Liu, Yun; Tang, Jian; Tang, Weihua, E-mail:


    Highlights: In this paper, we demonstrate: • The click synthesis of a AC regioisomer cationic cyclodextrin (CD) as chiral selector. • The good enantioselectivities (chiral resolution over 5) for acidic racemates. • The strong chiral recognition of new CD by NMR study. • Baseline enantioseparation of some acidic racemates at CD of 0.5 mM. - Abstract: In this work, a novel methoxypropylamino β-cyclodextrin (β-CD) clicked AC regioisomer, 6{sup A}-4-hydroxyethyl-1,2,3-triazolyl-6{sup C}-3-methoxypropylamino β-cyclodextrin (HETz-MPrAMCD), was synthesized via nucleophilic addition and click chemistry. The chiral separation ability of this AC regioisomer cationic CD was evaluated toward 7 ampholytic and 13 acidic racemates by capillary electrophoresis. Dependence of enantioselectivity and resolution on buffer pH (5.5–8.0) and chiral selector concentration (0.5–7.5 mM) was investigated. Enantioselectivities (α ≥ 1.05) could be achieved for most analytes under optimal conditions except dansyl-DL-noreleucine and dansyl-DL-serine. The highest resolutions for 2-chloromandelic acid p-hydroxymandelic acid were 15.6 and 9.7 respectively. The inclusion complexation between HETz-MPrAMCD and each 3-phenyllactic acid enantiomer was also revealed with nuclear magnetic resonance study.

  10. Miniaturizing free-flow electrophoresis - A critical review

    Kohlheyer, D.; Eijkel, J.C.T.; Berg, van den A.; Schasfoort, R.B.M.


    Free-flow electrophoresis (FFE) separation methods have been developed and investigated for around 50 years and have been applied not only to many types of analytes for various biomedical applications, but also for the separation of inorganic and organic substances. Its continuous sample preparation

  11. Gel Electrophoresis--The Easy Way for Students

    VanRooy, Wilhelmina; Sultana, Khalida


    This article describes a simple, inexpensive, easy to conduct gel-electrophoresis activity using food dyes. It is an alternative to the more expensive counterparts which require agarose gel, DNA samples, purchased chamber and Tris-borate-EDTA buffer. We suggest some learning activities for senior biology students along with comments on several…

  12. Pulsed-field gel electrophoresis typing of Staphylococcus aureus isolates

    Pulsed-field gel electrophoresis (PFGE) is the most applied and effective genetic typing method for epidemiological studies and investigation of foodborne outbreaks caused by different pathogens, including Staphylococcus aureus. The technique relies on analysis of large DNA fragments generated by th...

  13. Nanoparticle gel electrophoresis: bare charged spheres in polyelectrolyte hydrogels.

    Li, Fei; Hill, Reghan J


    Nanoparticle gel electrophoresis has recently emerged as an attractive means of separating and characterizing nanoparticles. Consequently, a theory that accounts for electroosmotic flow in the gel, and coupling of the nanoparticle and hydrogel electrostatics and hydrodynamics, is required, particularly for gels in which the mesh size is comparable to or smaller than the particle radii. Here, we present an electrokinetic model for charged, spherical colloidal particles undergoing electrophoresis in charged (polyelectrolyte) hydrogels: the gel-electrophoresis analogue of Henry's theory for electrophoresis in Newtonian electrolytes. We compare numerically exact solutions of the model with several independent asymptotic approximations, identifying regions in the parameter space where these approximations are accurate or break down. As previously assumed in the literature, Henry's formula, modified by the addition of a constant electroosmotic flow mobility, is accurate only for nanoparticles that are small compared to the hydrogel mesh size. We derived an exact analytical solution of the full model by judiciously modifying the theory of Allison et al. for uncharged gels, drawing on the superposition methodology of Doane et al. to account for hydrogel charge. This furnishes accurate and economical mobility predictions for the entire parameter space. The present model suggests that nanoparticle size separations (with diameters ≲40 nm) are optimal at low ionic strength, with a gel mesh size that is selected according to the particle charging mechanism. For weakly charged particles, optimal size separation is achieved when the Brinkman screening length is matched to the mean particle size. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. How it all began: a personal history of gel electrophoresis.

    Smithies, Oliver


    Arne Tiselius' moving boundary electrophoresis method was still in general use in 1951 when this personal history begins, although zonal electrophoresis with a variety of supporting media (e.g., filter paper or starch grains) was beginning to replace it. This chapter is an account of 10 years of experiments carried out by the author during which molecular sieving gel electrophoresis was developed and common genetic variants of two proteins, haptoglobin and transferrin, were discovered in normal individuals. Most of the figures are images of pages from the author's laboratory notebooks, which are still available, so that some of the excitement of the time and the humorous moments are perhaps apparent. Alkaline gels, acidic gels with and without denaturants, vertical gels, two-dimensional gels, and gels with differences in starch concentration are presented. The subtle details that can be discerned in these various gels played an indispensable role in determining the nature of the change in the haptoglobin gene (Hp) that leads to the polymeric series characteristic of Hp ( 2 ) /Hp ( 2 ) homozygotes. Where possible, the names of scientific friends who made this saga of gel electrophoresis so memorable and enjoyable are gratefully included.

  15. Gel Electrophoresis--The Easy Way for Students

    VanRooy, Wilhelmina; Sultana, Khalida


    This article describes a simple, inexpensive, easy to conduct gel-electrophoresis activity using food dyes. It is an alternative to the more expensive counterparts which require agarose gel, DNA samples, purchased chamber and Tris-borate-EDTA buffer. We suggest some learning activities for senior biology students along with comments on several…

  16. Serum protein fractionation using supported molecular matrix electrophoresis.

    Dong, Weijie; Matsuno, Yu-ki; Kameyama, Akihiko


    Supported molecular matrix electrophoresis (SMME), in which a hydrophilic polymer such as PVA serves as a support within a porous PVDF membrane, was recently developed. This method is similar to cellulose acetate membrane electrophoresis but differs in the compatibility to glycan analysis of the separated bands. In this report, we describe the first instance of the application of SMME to human serum fractionation, and demonstrate the differences with serum fractionation by cellulose acetate membrane electrophoresis. The SMME membrane exhibited almost no EOF during electrophoresis, unlike the cellulose acetate membrane, but afforded comparative results for serum fractionation. The visualization of each fraction was achieved by conventional staining with dye such as Direct Blue-71, and objective quantification was obtained by densitometry after inducing membrane transparency with 1-nonene. Immunostaining was also achieved. Moreover, mass spectrometric analysis of both N-linked and O-linked glycans from the separated bands was demonstrated. Serum fractionation and glycan profiling of each fraction using SMME will enable novel insights into the relationships between various glycosylation profiles and disease states.

  17. Explorative data analysis of two-dimensional electrophoresis gels

    Schultz, J.; Gottlieb, D.M.; Petersen, Marianne Kjerstine;


    Methods for classification of two-dimensional (2-DE) electrophoresis gels based on multivariate data analysis are demonstrated. Two-dimensional gels of ten wheat varieties are analyzed and it is demonstrated how to classify the wheat varieties in two qualities and a method for initial screening...

  18. Device for Horizontal Zone Electrophoresis in Free Electrolyte

    Priemyshev, A N; Bozhikov, G A; Alikov, B A; Salamatin, A V; Furyaev, T A; Maslov, O D; Milanov, M V; Dmitriev, S N


    With expansion of area of application of an electromigration method the necessity of modernization of installation for horizontal zone electrophoresis in free electrolyte has appeared. A number of the basic modules was essentially advanced, that has allowed considerably increase reliability and accuracy of received results. The device is completely automated.

  19. Capillary electrophoresis application in metal speciation and complexation characterization

    Capillary electrophoresis is amenable to the separation of metal ionic species and the characterization of metal-ligand interactions. This book chapter reviews and discusses three representative case studies in applications of CE technology in speciation and reactions of metal with organic molecules...

  20. Study of Oxidation of Glutathione by Capillary Electrophoresis


    A capillary electrophoresis method for the separation and quantification of reduced glutathione (GSH) and oxidized glutathione (GSSG) was developed. A baseline separation was achieved within five minutes. The effects of time and the concentrations of hydrogen peroxide (H2O2) on the oxidation of GSH were investigated.

  1. Automation and integration of polymerase chain reaction with capillary electrophoresis for high throughput genotyping and disease diagnosis

    Zhang, N.


    Genotyping is to detect specific loci in the human genome. These loci provide important information for forensic testing, construction of genetic linkage maps, gene related disease diagnosis and pharmacogenetic research. Genotyping is becoming more and more popular after these loci can be easily amplified by polymerase chain reaction (PCR). Capillary electrophoresis has its unique advantages for DNA analysis due to its fast heat dissipation and ease of automation. Four projects are described in which genotyping is performed by capillary electrophoresis emphasizing different aspects. First, the author demonstrates a principle to determine the genotype based on capillary electrophoresis system. VNTR polymorphism in the human D1S80 locus was studied. Second, the separation of four short tandem repeat (STR) loci vWF, THO1, TPOX and CSF1PO (CTTv) by using poly(ethylene oxide) (PEO) was studied in achieving high resolution and preventing rehybridization of the DNA fragments. Separation under denaturing, non-denaturing conditions and at elevated temperature was discussed. Third, a 250 {micro}m i.d., 365 {micro}m o.d. fused silica capillary was used as the microreactor for PCR. Fourth, direct PCR from blood was studied to simplify the sample preparation for genotyping to minimum.

  2. Detection of low-molecular weight allergens resolved on two-dimensional electrophoresis with acid-urea polyacrylamide gel.

    Kitta, Kazumi; Ohnishi-Kameyama, Mayumi; Moriyama, Tatsuya; Ogawa, Tadashi; Kawamoto, Shinichi


    Two-dimensional electrophoresis with immobilized pH gradient (IPG) followed by acetic acid/urea-polyacrylamide gel electrophoresis (AU-PAGE) was developed for the detection of low-molecular weight food allergens. Wheat proteins were used to test the applicability of AU-PAGE for the analysis of food allergens. Isoelectric focusing (IEF) for first dimension was performed with IPG pH 3-10. AU-PAGE was performed as a second-dimensional electrophoresis and high resolution was obtained, especially for proteins below 15 kDa. For immunodetection, the proteins resolved on AU gel were transferred to a polyvinylidene difluoride membrane. The assembly of semidry electroblotting for AU gel was set reversed as for sodium dodecyl sulfate (SDS)-PAGE gel. The electroblotted membrane was immunolabeled with serum from a radio-allergosorbent test-positive individual for wheat to identify allergenic proteins. Protein spots strongly recognized by the patient's serum were chosen for further analysis. Mass spectrometry analysis revealed that these proteins were alpha-amylase/trypsin inhibitors and lipid transfer protein. The system developed in this study was shown to be useful as a standard protocol for the separation of low-molecular weight proteins. Moreover, the IPG strips on which IEF was performed could be used either for SDS-PAGE or AU-PAGE by only changing equilibrating conditions, allowing for a wide range of allergen analysis.

  3. 16-BAC/SDS-PAGE analysis of membrane proteins of yeast mitochondria purified by free flow electrophoresis.

    Braun, Ralf J; Kinkl, Norbert; Zischka, Hans; Ueffing, Marius


    Mitochondria are essential organelles in cellular metabolism. These organelles are bounded by two membranes, the outer and inner membrane. Especially the inner membrane comprises a high content of proteins, for example, the protein complexes of the respiratory chain. High-resolution separation and analysis of such membrane proteins, for example, by two-dimensional gel electrophoresis (2-DE), is hampered by their hydrophobicity and tendency for aggregation. Here, we describe the separation of mitochondrial membrane proteins of Saccharomyces cerevisiae by 16-benzyldimethyl-n-hexadecylammonium chloride/sodium dodecyl sulfate polyacrylamide gel electrophoresis (16-BAC/SDS-PAGE). This method enables the separation of membrane proteins owing to the solubilizing power of the ionic detergents 16-BAC and SDS, respectively. Mitochondria were isolated from yeast cultures by differential centrifugation and were further purified by free flow electrophoresis (FFE) in zone-electrophoretic mode (ZE). Subsequently, membrane proteins from ZE-FFE-purified mitochondria were enriched by carbonate extraction and subjected to 16-BAC/SDS-PAGE. The resulting protein spot patterns were visualized by a highly sensitive fluorescence stain with ruthenium-II-bathophenantroline disulfonate chelate (RuBP), and by colloidal Coomassie staining. Proteins were identified by Maldi-Tof mass spectrometry and peptide mass fingerprinting.

  4. Labeling of double-stranded DNA by ROX-dideoxycytosine triphosphate using terminal deoxynucleotidyl transferase and separation by capillary electrophoresis

    Figeys, D.; Renborg, A.; Dovichi, N.J. (Univ. of Alberta, Edmonton, Alberta (Canada))


    Terminal transferase is used to add a single fluorescently labeled dideoxynucleotide to double-stranded DNA prepared by restriction endonuclease action on a bacteriophage. The product is separated by capillary electrophoresis with both hydroxypropylmethylcellulose and non-cross-linked polyacrylamide. The reaction products generate single peaks for each fragment with hydroxypropylmethylcellulose. However, the higher resolution separation produced by non-cross-linked polyacrylamide shows that the product contains two components for each restriction digest fragment. This labeling technique should be useful in restriction fragment length polymorphism studies. 9 refs., 2 figs.

  5. Proteins of human urine. II. Identification by two-dimensional electrophoresis of a new candidate marker for prostatic cancer

    Edwards, J.J. (Argonne National Lab., IL); Anderson, N.G.; Tollaksen, S.L.; von Eschenbach, A.C.; Guevara, J. Jr.


    A protein series common to the urine and prostatic tissue of 16 of 17 patients with prostatic adenocarcinoma has been identified by high-resolution two-dimensional gel electrophoresis. These proteins, designated PCA-1, have a relative molecular mass in sodium dodecyl sulfate of about 40,000. Analyses of urines from eight age-matched controls, seven patients with other types of urogenital malignancies, two patients with benign prostatic hyperplasia, and five patients with malignancies not associated with the urogenital system failed to show PCA-1 in the patterns. These preliminary findings suggest that this protein should be systematically investigated as a candidate marker for prostatic adenocarcinoma in man.

  6. A Study on Major Components of Bee Venom Using Electrophoresis

    Lee, Jin-Seon


    Full Text Available This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K -BV II, 0.5rng/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg /ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV using Electrophoresis. The results were summarized as follows: 1. In 1:4000 Bee Venom solution rate, the band was not displayed distinctly usmg Electrophoresis. But in 1: 1000, the band showed clearly. 2. The results of Electrophoresis at solution rate 1:1000, K-BV I and K-BVII showed similar band. 3. The molecular weight of Phospholipase A2 was known as 19,000 but its band was seen at 17,000 in Electrophoresis. 4. Protein concentration of Bee Venom by Lowry method was different at solution rate 1:4000 ; C-BV was 250μg/ml, K-BV I was 190μg/ml, K-BV Ⅱ was 160μg/ml and C-BV was 45μg/ml. 5. Electrophoresis method was unuseful for analysis of Bee Venom when solution rate is above 1:4000 but Protein concentration of Bee Venom by Lowry method was possible. These data from the study can be applied to establish the standard measurement of Bee Venom and prevent pure bee venom from mixing of another components. I think it is desirable to study more about safety of Bee Venom as time goes by.

  7. Capillaries modified by noncovalent anionic polymer adsorption for capillary zone electrophoresis, micellar electrokinetic capillary chromatography and capillary electrophoresis mass spectrometry

    Bendahl, L; Hansen, S H; Gammelgaard, Bente


    A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene...

  8. Gap Resolution


    Gap Resolution is a software package that was developed to improve Newbler genome assemblies by automating the closure of sequence gaps caused by repetitive regions in the DNA. This is done by performing the follow steps:1) Identify and distribute the data for each gap in sub-projects. 2) Assemble the data associated with each sub-project using a secondary assembler, such as Newbler or PGA. 3) Determine if any gaps are closed after reassembly, and either design fakes (consensus of closed gap) for those that closed or lab experiments for those that require additional data. The software requires as input a genome assembly produce by the Newbler assembler provided by Roche and 454 data containing paired-end reads.

  9. A continuous acetic acid system for polyacrylamide gel electrophoresis of gliadins and other prolamines.

    Clements, R L


    A polyacrylamide gel electrophoresis system buffered by acetic acid alone was developed for electrophoresis of prolamines. When applied to gliadin electrophoresis, the acetic acid system produces more bands than does a conventional aluminum lactate-lactic acid system (using 12% acrylamide gels). The acetic acid system is relatively simple, requiring a single buffer component that is universally available in high purity.

  10. Usage of Capillary Electrophoresis for screening common Hemoglobinopathies


    Full Text Available Hemoglobinopathies are most common inherited disorders in the world approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. For control of this inherited hemoglobin disorders need to accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid & more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias & hemoglobin variants Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as Gel electrophoresis, High performance liquid chromatography, Isoelectric focusing, Capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two complementary methods for hemoglobinopathies screening. We can analyze by the methods more hemoglobin disorders and decrease more laboratory errors. Moreover

  11. Agarose gel electrophoresis for the separation of DNA fragments.

    Lee, Pei Yun; Costumbrado, John; Hsu, Chih-Yuan; Kim, Yong Hoon


    Agarose gel electrophoresis is the most effective way of separating DNA fragments of varying sizes ranging from 100 bp to 25 kb(1). Agarose is isolated from the seaweed genera Gelidium and Gracilaria, and consists of repeated agarobiose (L- and D-galactose) subunits(2). During gelation, agarose polymers associate non-covalently and form a network of bundles whose pore sizes determine a gel's molecular sieving properties. The use of agarose gel electrophoresis revolutionized the separation of DNA. Prior to the adoption of agarose gels, DNA was primarily separated using sucrose density gradient centrifugation, which only provided an approximation of size. To separate DNA using agarose gel electrophoresis, the DNA is loaded into pre-cast wells in the gel and a current applied. The phosphate backbone of the DNA (and RNA) molecule is negatively charged, therefore when placed in an electric field, DNA fragments will migrate to the positively charged anode. Because DNA has a uniform mass/charge ratio, DNA molecules are separated by size within an agarose gel in a pattern such that the distance traveled is inversely proportional to the log of its molecular weight(3). The leading model for DNA movement through an agarose gel is "biased reptation", whereby the leading edge moves forward and pulls the rest of the molecule along(4). The rate of migration of a DNA molecule through a gel is determined by the following: 1) size of DNA molecule; 2) agarose concentration; 3) DNA conformation(5); 4) voltage applied, 5) presence of ethidium bromide, 6) type of agarose and 7) electrophoresis buffer. After separation, the DNA molecules can be visualized under uv light after staining with an appropriate dye. By following this protocol, students should be able to: Understand the mechanism by which DNA fragments are separated within a gel matrix Understand how conformation of the DNA molecule will determine its mobility through a gel matrix Identify an agarose solution of appropriate

  12. Assessing resolution in super-resolution imaging.

    Demmerle, Justin; Wegel, Eva; Schermelleh, Lothar; Dobbie, Ian M


    Resolution is a central concept in all imaging fields, and particularly in optical microscopy, but it can be easily misinterpreted. The mathematical definition of optical resolution was codified by Abbe, and practically defined by the Rayleigh Criterion in the late 19th century. The limit of conventional resolution was also achieved in this period, and it was thought that fundamental constraints of physics prevented further increases in resolution. With the recent development of a range of super-resolution techniques, it is necessary to revisit the concept of optical resolution. Fundamental differences in super-resolution modalities mean that resolution is not a directly transferrable metric between techniques. This article considers the issues in resolution raised by these new technologies, and presents approaches for comparing resolution between different super-resolution methods.

  13. Rapid DNA sequencing by horizontal ultrathin gel electrophoresis.

    Brumley, R L; Smith, L M


    A horizontal polyacrylamide gel electrophoresis apparatus has been developed that decreases the time required to separate the DNA fragments produced in enzymatic sequencing reactions. The configuration of this apparatus and the use of circulating coolant directly under the glass plates result in heat exchange that is approximately nine times more efficient than passive thermal transfer methods commonly used. Bubble-free gels as thin as 25 microns can be routinely cast on this device. The application to these ultrathin gels of electric fields up to 250 volts/cm permits the rapid separation of multiple DNA sequencing reactions in parallel. When used in conjunction with 32P-based autoradiography, the DNA bands appear substantially sharper than those obtained in conventional electrophoresis. This increased sharpness permits shorter autoradiographic exposure times and longer sequence reads. Images PMID:1870968

  14. Blood grouping based on PCR methods and agarose gel electrophoresis.

    Sell, Ana Maria; Visentainer, Jeane Eliete Laguila


    The study of erythrocyte antigens continues to be an intense field of research, particularly after the development of molecular testing methods. More than 300 specificities have been described by the International Society for Blood Transfusion as belonging to 33 blood group systems. The polymerase chain reaction (PCR) is a central tool for red blood cells (RBC) genotyping. PCR and agarose gel electrophoresis are low cost, easy, and versatile in vitro methods for amplifying defined target DNA (RBC polymorphic region). Multiplex-PCR, AS-PCR (Specific Allele Polymerase Chain Reaction), and RFLP-PCR (Restriction Fragment Length Polymorphism-Polymerase Chain Reaction) techniques are usually to identify RBC polymorphisms. Furthermore, it is an easy methodology to implement. This chapter describes the PCR methodology and agarose gel electrophoresis to identify the polymorphisms of the Kell, Duffy, Kidd, and MNS blood group systems.

  15. Candidate gene copy number analysis by PCR and multicapillary electrophoresis.

    Szantai, Eszter; Elek, Zsuzsanna; Guttman, András; Sasvari-Szekely, Maria


    Genetic polymorphisms are often considered as risk factors of complex diseases serving as valuable and easily detectable biomarkers, also stable during the whole lifespan. A novel type of genetic polymorphism has been identified just recently, referred to as gene copy number variation (CNV) or copy number polymorphism. CNV of glycogen synthase kinase 3 beta and its adjacent gene, Nr1i2 (pregnane X receptor isoform), has been reported to associate with bipolar depression. In our study we introduced multicapillary electrophoresis for gene copy number analysis as an affordable alternative to real-time PCR quantification with TaqMan gene probes. Our results show the reliability of the developed method based on conventional PCR followed by separation of products by multicapillary electrophoresis with quantitative evaluation. This method can be readily implemented for the analysis of candidate gene CNVs in high throughput clinical laboratories and also in personalized medicine care of depression-related risk factors.

  16. Microchip electrophoresis at elevated temperatures and high separation field strengths.

    Mitra, Indranil; Marczak, Steven P; Jacobson, Stephen C


    We report free-solution microchip electrophoresis performed at elevated temperatures and high separation field strengths. We used microfluidic devices with 11 cm long separation channels to conduct separations at temperatures between 22 (ambient) and 45°C and field strengths from 100 to 1000 V/cm. To evaluate separation performance, N-glycans were used as a model system and labeled with 8-aminopyrene-1,3,6-trisulfonic acid to impart charge for electrophoresis and render them fluorescent. Typically, increased diffusivity at higher temperatures leads to increased axial dispersion and poor separation performance; however, we demonstrate that sufficiently high separation field strengths offset the impact of increased diffusivity in order to maintain separation efficiency. Efficiencies for these free-solution separations are the same at temperatures of 25, 35, and 45°C with separation field strengths ≥ 500 V/cm.

  17. Versatile electrophoresis-based self-test platform.

    Guijt, Rosanne M


    Lab on a Chip technology offers the possibility to extract chemical information from a complex sample in a simple, automated way without the need for a laboratory setting. In the health care sector, this chemical information could be used as a diagnostic tool for example to inform dosing. In this issue, the research underpinning a family of electrophoresis-based point-of-care devices for self-testing of ionic analytes in various sample matrices is described [Electrophoresis 2015, 36, 712-721.]. Hardware, software, and methodological chances made to improve the overall analytical performance in terms of accuracy, precision, detection limit, and reliability are discussed. In addition to the main focus of lithium monitoring, new applications including the use of the platform for veterinary purposes, sodium, and for creatinine measurements are included.

  18. Electrophoresis of a DNA Coil Near a Nanopore

    Rowghanian, Payam


    Motivated by DNA electrophoresis near a nanopore, we consider the flow field around an "elongated jet", a long thin source which injects momentum into a liquid. This solution qualitatively describes the electro-osmotic flow around a long rigid polymer, where due to electrohydrodynamic coupling, the solvent receives momentum from the electric field. Based on the qualitative behavior of the elongated jet solution, we develop a coarse-grained scheme which reproduces the known theoretical results regarding the electrophoretic behavior of a long rigid polymer and a polymer coil in a uniform field, which we then exploit to analyze the electrophoresis of a polymer coil in the non-uniform field near a nanopore.

  19. Affinity Electrophoresis for Analysis of Catalytic Module-Carbohydrate Interactions

    Cockburn, Darrell; Wilkens, Casper; Svensson, Birte


    Affinity electrophoresis has long been used to study the interaction between proteins and large soluble ligands. The technique has been found to have great utility for the examination of polysaccharide binding by proteins, particularly carbohydrate binding modules (CBMs). In recent years, carbohy......Affinity electrophoresis has long been used to study the interaction between proteins and large soluble ligands. The technique has been found to have great utility for the examination of polysaccharide binding by proteins, particularly carbohydrate binding modules (CBMs). In recent years......, carbohydrate surface binding sites of proteins mostly enzymes have also been investigated by this method. Here, we describe a protocol for identifying binding interactions between enzyme catalytic modules and a variety of carbohydrate ligands....

  20. Poly(dimethylsiloxane) based microchip for DNA electrophoresis

    LIU Changchun; CUI Dafu; WANG Li


    A novel poly(dimethylsiloxane)(PDMS) -based microchip for DNA separation through electrophoresis has been developed using a micro-electro-mechanical-system(MEMS) technology. Unlike previous hybrid PDMS microchip, one PDMS film is first created on glass support by pressing method in our microchip. Thus, increased band-broadening phenomena, arising from the material nonuniformity at the walls of microchannel, can be avoided in electrophoresis process. A low-viscosity hydroxypropylmethylcellulose-100 (HPMC-100) is used as the separation medium for fluorescent intercalator-labeled double-stranded DNA (dsDNA) fragments. Mannitol is introduced to PDMS-based microchip as a separation medium additive to enhance separation efficiency. At applied electric field strength of 150 V/cm, excellent separations of the PCR marker could be achieved with an effective separation distance of 25mm .

  1. Generalized Resolution and NC—Resolution

    刘叙华; 孙吉贵


    The relation between generalized resolution and NC-resolution is discussed.The proof of the completeness of NC linear resolution is then given.The incompleteness of NC lock resolution is also presented,thus the conclusion in [3] of “a simple completeness-preserving restriction” is shown to be wrong.

  2. Extraction of plant proteins for two-dimensional electrophoresis

    Granier, Fabienne


    Three different extraction procedures for two-dimensional electrophoresis of plant proteins are compared: (i) extraction of soluble proteins with a nondenaturing Tris-buffer, (ii) denaturing extraction in presence of sodium dodecyl sulfate at elevated temperature allowing the solubilization of membrane proteins in addition to a recovery of soluble proteins, and (iii) a trichloroacetic acid-acetone procedure allowing the direct precipitation of total proteins.

  3. Simultaneous quantification of sialyloligosaccharides from human milk by capillary electrophoresis


    The acidic oligosaccharides of human milk are predominantly sialyloligosaccharides. Pathogens that bind sialic acid-containing glycans on their host mucosal surfaces may be inhibited by human milk sialyloligosaccharides, but testing this hypothesis requires their reliable quantification in milk. Sialyloligosaccharides have been quantified by anion exchange HPLC, reverse or normal phase HPLC, and capillary electrophoresis (CE) of fluorescent derivatives; in milk, these oligosaccharides have be...

  4. Precise small volume sample handling for capillary electrophoresis.

    Mozafari, Mona; Nachbar, Markus; Deeb, Sami El


    Capillary electrophoresis is one of the most important analytical techniques. Although the injected sample volume in capillary electrophoresis is only in the nanoliter range, most commercial CE-instruments need approximately 50 μL of the sample in the injection vial to perform the analysis. Hence, in order to fully profit from the low injection volumes, smaller vial volumes are required. Thus experiments were performed using silicone oil which has higher density than water (1.09 g/mL) to replace sample dead volume in the vial. The results were compared to those performed without using the silicone oil in the sample vial. As an example five standard proteins namely beta-lactoglobulin, BSA, HSA, Myoglobin and Ovalbumin, and one of the coagulation cascade involved proteins called vitonectin were investigated using capillary electrophoresis. Mobility ratios and peak areas were compared. However no significant changes were observed (RSDs% for mobility ratios and peak areas were better than 0.9% and 5.8% respectively). Afterwards an affinity capillary electrophoresis method was used to investigate the interactions of two proteins, namely HSA and vitronectin, with three ligands namely enoxaparin sodium, unfractionated heparin and pentosan polysulfate sodium (PPS). Mobility shift precision results showed that the employment of the filling has no noticeable effect on any of the protein-ligand interactions. Using a commercial PrinCE instrument and an autosampler the required sample volume is reduced down to 10 μL, and almost this complete volume can be subsequently injected during repeated experiments. This article is protected by copyright. All rights reserved.

  5. A fully automated multicapillary electrophoresis device for DNA analysis.

    Behr, S; Mätzig, M; Levin, A; Eickhoff, H; Heller, C


    We describe the construction and performance of a fully automated multicapillary electrophoresis system for the analysis of fluorescently labeled biomolecules. A special detection system allows the simultaneous spectral analysis of all 96 capillaries. The main features are true parallel detection without any moving parts, high robustness, and full compatibility to existing protocols. The device can process up to 40 microtiter plates (96 and 384 well) without human interference, which means up to 15,000 samples before it has to be reloaded.

  6. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.


    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  7. [Development of a droplet-interfaced high performance liquid chromatography-capillary electrophoresis two dimensional separation platform].

    Ye, Linquan; Wu, Qingshi; Dai, Simin; Xiao, Zhiliang; Zhang, Bo


    Proteomics demands high resolution multidimensional separation techniques due to its extremely high complexity. Droplet microfluidics provides a series of unique advantages in manipulating micro and nanolitre samples, such as micro-volume operation, limited diffusion and none cross-contaminating, therefore has the potential to be an ideal interface strategy for multidimensional separation. Using the microchips of different structures, functions such as "droplet generation" and "oil depletion" can be realized. Based on these functions, samples can be transferred from continuous flow to segmented flow and then back to continuous flow. In this way, different separation modes can be combined. In this study, droplet technology was utilized as a novel interface strategy in combining high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using tryptic peptides mixture as a sample, this two dimensional HPLC-CE system provided high resolution separation with a peak capacity over 3000. This proof-of-principle study has demonstrated the usefulness of droplet interface technology in multidimensional separation.

  8. Optimization strategies for separation of sulfadiazines using Box-Behnken design by liquid chromatography and capillary electrophoresis

    GONG Wen-jun; ZHANG Yu-ping; ZHANG Yi-Jun; XU Guang-ri; WEI Xin-jun; LEE Kwang-pill


    Development of effective chromatographic or electrophoretic separation involves judicious deciding of selection of optimal experimental conditions that can provide an adequate resolution at a reasonable run time for the separation of interested components. Box-Behnken factorial design was effectively applied for the separation optimization of eight structurally related sulfonamides using capillary zone electrophorosis and reverse high performance liquid chromatography. Optimum values for volume ratio of THF to H2O in eluent, column temperature and flow rate of eluent are found as 12 to 88, 35 ℃ and 1.0 mL/min, respectively.Box-Behnken modified optimization model is extended to separation by capillary electrophoresis (CE). While using CE, a satisfactory separation is achieved with a minimum resolution larger than 1.0 for a separation time less than 10 min.

  9. Automated Lab-on-a-Chip Electrophoresis System

    Willis, Peter A.; Mora, Maria; Greer, Harold F.; Fisher, Anita M.; Bryant, Sherrisse


    Capillary electrophoresis is an analytical technique that can be used to detect and quantify extremely small amounts of various biological molecules. In the search for biochemical traces of life on other planets, part of this search involves an examination of amino acids, which are the building blocks of life on Earth. The most sensitive method for detecting amino acids is the use of laser induced fluorescence. However, since amino acids do not, in general, fluoresce, they first must be reacted with a fluorescent dye label prior to analysis. After this process is completed, the liquid sample then must be transported into the electrophoresis system. If the system is to be reused multiple times, samples must be added and removed each time. In typical laboratories, this process is performed manually by skilled human operators using standard laboratory equipment. This level of human intervention is not possible if this technology is to be implemented on extraterrestrial targets. Microchip capillary electrophoresis (CE) combined with laser induced fluorescence detection (LIF) was selected as an extremely sensitive method to detect amino acids and other compounds that can be tagged with a fluorescent dye. It is highly desirable to package this technology into an integrated, autonomous, in situ instrument capable of performing CE-LIF on the surface of an extraterrestrial body. However, to be fully autonomous, the CE device must be able to perform a large number of sample preparation and analysis operations without the direct intervention of a human.

  10. Two-dimensional capillary electrophoresis using tangentially connected capillaries.

    Sahlin, Eskil


    A novel type of fused silica capillary system is described where channels with circular cross-sections are tangentially in contact with each other and connected through a small opening at the contact area. Since the channels are not crossing each other in the same plane, the capillaries can easily be filled with different solutions, i.e. different solutions will be in contact with each other at the contact point. The system has been used to perform different types of two-dimensional separations and the complete system is fully automated where a high voltage switch is used to control the location of the high voltage in the system. Using two model compounds it is demonstrated that a type of two-dimensional separation can be performed using capillary zone electrophoresis at two different pH values. It is also shown that a compound with acid/base properties can be concentrated using a dynamic pH junction mechanism when transferred from the first separation to the second separation. In addition, the system has been used to perform a comprehensive two-dimensional capillary electrophoresis separation of tryptic digest of bovine serum albumin using capillary zone electrophoresis followed by micellar electrokinetic chromatography.

  11. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario


    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  12. Preparative displacement electrophoresis (isotachophoresis) of proteins on cellulose columns.

    Johansson, G; Ofverstedt, L G; Hjertén, S


    This paper describes the separation of proteins by displacement electrophoresis on columns packed with cellulose powder as a stabilizing medium. Cellulose has virtually no molecular sieving properties and thus differs from dextran, polyacrylamide, and agarose in this respect. Therefore, without the risk of unstacking, columns packed with cellulose permit conventional elution of the protein zones and the use of a counter flow (to increase the effective length of the bed). For the same reason, electroosmotic flow is less disturbing. A continuous elution-migration technique adapted to suit the special requirements of displacement electrophoresis gave better separation than was obtainable by conventional elution. Normal human serum and a fresh hemolysate from human erythrocytes were used as samples. An expression for the volume velocity of the boundaries is derived. This parameter can be used to determine the maximum duration of a run and a suitable pump speed when continuous elution or a counter flow is employed. The special advantages of displacement electrophoresis in cellulose beds are discussed as well as general disadvantages of the displacement technique, including the risk that proteins precipitate during a run.

  13. Attempt to run urinary protein electrophoresis using capillary technique.

    Falcone, Michele


    The study of urinary protein has a predominant place in the diagnosis of kidney disease. The most common technique is agarose gel electrophoresis (AGE). For several years, the technique of choice applied to the analysis of serum proteins has been CE, a system that uses capillary fused silica, subjected to high voltage to separate and measure serum proteins. The purpose of this paper was to perform capillary electrophoresis on urinary proteins which, at present, are not interpretable due to the many nonspecific peaks visible when using gel electrophoresis. In order to carry out our research, we used a capillary V8 analyzer together with an agarose gel system from the same company. AGE was taken as the reference method, for which urine was used without any pretreatment. For the V8 system, urine was subjected to purification on granular-activated carbon and then inserted into the V8 analyzer, selecting a program suitable for liquids with low protein content. We examined 19 urine samples collected over 24 hrs from both hospitalized and external patients with different types of proteinuria plus a serum diluted 1/61 considered as a control to recognize the bands. Both methods showed the same protein fractions and classified the proteinuria in a similar way.

  14. Visualization of DNA molecules in time during electrophoresis

    Lubega, Seth


    For several years individual DNA molecules have been observed and photographed during agarose gel electrophoresis. The DNA molecule is clearly the largest molecule known. Nevertheless, the largest molecule is still too small to be seen using a microscope. A technique developed by Morikawa and Yanagida has made it possible to visualize individual DNA molecules. When these long molecules are labeled with appropriate fluorescence dyes and observed under a fluorescence microscope, although it is not possible to directly visualize the local ultrastructure of the molecules, yet because they are long light emitting chains, their microscopic dynamical behavior can be observed. This visualization works in the same principle that enables one to observe a star through a telescope because it emits light against a dark background. The dynamics of individual DNA molecules migrating through agarose matrix during electrophoresis have been described by Smith et al. (1989), Schwartz and Koval (1989), and Bustamante et al. (1990). DNA molecules during agarose gel electrophoresis advance lengthwise thorough the gel in an extended configuration. They display an extension-contraction motion and tend to bunch up in their leading ends as the 'heads' find new pores through the gel. From time to time they get hooked on obstacles in the gel to form U-shaped configurations before they resume their linear configuration.

  15. Capillary electrophoresis to determine entrapment efficiency of a nanostructured lipid carrier loaded with piroxicam

    Jessica Otarola; Adriana Guillermina Lista; Beatriz Fernández Band; Mariano Garrido


    A simple and fast capillary electrophoresis method has been developed to determine the amount of piroxicam loaded in a drug delivery system based on nanostructured lipid carriers (NLCs). The entrapment efficiency of the nanostructured lipid carrier was estimated by measuring the concentration of drug not entrapped in a suspension of NLC. The influence of different parameters on migration times, peak symmetry, efficiency and resolution was studied; these parameters included the pH of the electrophoretic buffer solution and the applied voltage. The piroxicam peak was obtained with a satisfactory resolution. The separation was carried out using a running buffer composed of 50 mM ammonium acetate and 13.75 mM ammonia at pH 9. The optimal voltage was 20 kV and the cartridge temperature was 20 1C. The corresponding calibration curve was linear over the range of 2.7–5.4 mg/mL of NLC suspension. The reproducibility of migration time and peak area were investigated, and the obtained RSD% values (n ¼ 5) were 0.99 and 2.13, respectively.

  16. Capillary electrophoresis to determine entrapment efficiency of a nanostructured lipid carrier loaded with piroxicam

    Jessica Otarola


    Full Text Available A simple and fast capillary electrophoresis method has been developed to determine the amount of piroxicam loaded in a drug delivery system based on nanostructured lipid carriers (NLCs. The entrapment efficiency of the nanostructured lipid carrier was estimated by measuring the concentration of drug not entrapped in a suspension of NLC. The influence of different parameters on migration times, peak symmetry, efficiency and resolution was studied; these parameters included the pH of the electrophoretic buffer solution and the applied voltage. The piroxicam peak was obtained with a satisfactory resolution. The separation was carried out using a running buffer composed of 50 mM ammonium acetate and 13.75 mM ammonia at pH 9. The optimal voltage was 20 kV and the cartridge temperature was 20 °C. The corresponding calibration curve was linear over the range of 2.7–5.4 µg/mL of NLC suspension. The reproducibility of migration time and peak area were investigated, and the obtained RSD% values (n=5 were 0.99 and 2.13, respectively.

  17. Determination of impurities in heparin by capillary electrophoresis using high molarity phosphate buffers.

    Wielgos, Todd; Havel, Karalyn; Ivanova, Nadia; Weinberger, Robert


    Oversulfated chondroitin sulfate (OSCS), an impurity found in some porcine intestinal heparin samples was separated from intact heparin by capillary electrophoresis (CE) using a 600mM phosphate buffer, pH 3.5 as the background electrolyte in a 56cm x 25microm i.d. capillary. This method was confirmed in two separate labs, was shown to be linear, reproducible, robust, easy to use and provided the highest resolution and superior limits of detection compared to other available CE methods. Glycosoaminoglycans such as dermatan sulfate and heparan sulfate were separated and quantified as well during a single run. The heparin peak area response correlated well to values obtained using the official assay for biological activity. A high speed, high resolution version of the method was developed using 600mM lithium phosphate, pH 2.8 in a 21.5cm x 25microm i.d. capillary which provided limits of detection for OSCS that were below 0.1%.

  18. Enantioseparation of atropine by capillary electrophoresis using sulfated beta-cyclodextrin: application to a plant extract.

    Mateus, L; Cherkaoui, S; Christen, P; Veuthey, J L


    A capillary zone electrophoresis (CZE) method, with sulfated beta-CD as chiral selector, was optimized by means of an experimental design for the enantioseparation of atropine. In this study, a central composite design was used and the following factors were varied simultaneously: buffer concentration, buffer pH and sulfated beta-CD concentration. The resolutions between littorine and its positional isomer ((-)-hyoscyamine) and between atropine enantiomers, as well as the separation time and generated current were established as responses. A model was obtained for each response by linear multiple regression of a second-degree mathematical expression. The most favorable conditions were determined by maximizing the resolution between atropine enantiomers and by setting the other responses at threshold values. Successful results were obtained with a 55 mM phosphate buffer at pH 7 in the presence of 2.9 mM sulfated-beta-CD at 20 degrees C and 20 kV. Under these optimized conditions, a baseline separation of littorine and atropine enantiomers was achieved in less than 5 min. Finally, the method allowed the enantiomeric separation of atropine in a pharmaceutical formulation and was also found to be suitable for the enantiomeric purity evaluation of (-)-hyoscyamine in plant extracts, in relation with the extraction procedure. It was demonstrated that supercritical fluid extraction induced less racemization than classical liquid-solid extraction procedures.

  19. Applications of space-electrophoresis in medicine. [for cellular separations in molecular biology

    Bier, M.


    The nature of electrophoresis is reviewed and potential advances realizable in the field of biology and medicine from a space electrophoresis facility are examined. The ground-based applications of electrophoresis: (1) characterization of an ionized species; (2) determination of the quantitative composition of a complex mixture; and (3) isolation of the components of a mixture, separation achieved on the basis of the difference in transport rates is reviewed. The electrophoresis of living cells is considered, touching upon the following areas: the separation of T and B lymphocytes; the genetic influence on mouse lymphocyte mobilities; the abnormal production of specific and monoclonal immunoproteins; and the study of cancer. Schematic diagrams are presented of three types of electrophoresis apparatus: the column assembly for the static electrophoresis experiment on the Apollo-Soyuz mission, the continuous flow apparatus used in the same mission and a miniaturized electrophoresis apparatus.

  20. Applications of space-electrophoresis in medicine. [for cellular separations in molecular biology

    Bier, M.


    The nature of electrophoresis is reviewed and potential advances realizable in the field of biology and medicine from a space electrophoresis facility are examined. The ground-based applications of electrophoresis: (1) characterization of an ionized species; (2) determination of the quantitative composition of a complex mixture; and (3) isolation of the components of a mixture, separation achieved on the basis of the difference in transport rates is reviewed. The electrophoresis of living cells is considered, touching upon the following areas: the separation of T and B lymphocytes; the genetic influence on mouse lymphocyte mobilities; the abnormal production of specific and monoclonal immunoproteins; and the study of cancer. Schematic diagrams are presented of three types of electrophoresis apparatus: the column assembly for the static electrophoresis experiment on the Apollo-Soyuz mission, the continuous flow apparatus used in the same mission and a miniaturized electrophoresis apparatus.

  1. Is pulsed electric field still effective for RNA separation in capillary electrophoresis?

    Li, Zhenqing; Dou, Xiaoming; Ni, Yi; Chen, Qinmiao; Cheng, Shuyi; Yamaguchi, Yoshinori


    Pulsed field capillary electrophoresis (PFCE) is a predominant technique to cope with difficulties in resolving large DNA strands, yet it is still unclear whether pulsed electric field is effective for the separation of higher mass RNA. In this paper we focused on the role of pulsed electric field in large RNA fragments analysis by comparing RNA separation performance in PFCE with that in constant field CE. Separation performance in terms of migration mobility, plate numbers, resolution, and selectivity has been tested for the analysis of RNA from 0.1 to 10.0 kilo nucleotide (knt) under different electrophoretic conditions. Denaturation, important to obtain uniform and identifiable peaks, was accomplished by heating the sample in 4.0M urea prior to analysis and the presence of 4.0M urea in the electrophoresis buffer. Results demonstrate that unlike DNA in PFCE, the pulsed electric field mainly affects the separation performance of RNA between 0.4 and 2.0 knt. The migration mobility of long RNA fragments is not a strong function of modulation depth and pulsed frequency. Moreover, the logarithm of RNA mobility is almost inversely proportional to the logarithm of molecule size up to 6.0 knt with correlation coefficient higher than 0.99 in all the polymer concentrations measured here. Resonance frequency of RNA in PFCE was also observed. While these initial experiments show no distinct advantages of using PFCE for RNA separation, they do take further step toward characterizing the migration behavior of RNA under pulsed field conditions.

  2. Quantitative, small-scale, fluorophore-assisted carbohydrate electrophoresis implemented on a capillary electrophoresis-based DNA sequence analyzer.

    Murray, Sarah; McKenzie, Marian; Butler, Ruth; Baldwin, Samantha; Sutton, Kevin; Batey, Ian; Timmerman-Vaughan, Gail M


    Fluorophore-assisted carbohydrate electrophoresis (FACE) is an analytical method for characterizing carbohydrate chain length that has been applied to neutral, charged, and N-linked oligosaccharides and that has been implemented using diverse separation platforms, including polyacrylamide gel electrophoresis and capillary electrophoresis. In this article, we describe three substantial improvements to FACE: (i) reducing the amount of starch and APTS required in labeling reactions and systematically analyzing the effect of altering the starch and 8-amino-1,3,6-pyrenetrisulfonic acid (APTS) concentrations on the reproducibility of the FACE peak area distributions; (ii) implementing FACE on a multiple capillary DNA sequencer (an ABI 3130xl), enabling higher throughput than is possible on other separation platforms; and (iii) developing a protocol for producing quantitative output of peak heights and areas using genetic marker analysis software. The results of a designed experiment to determine the effect of decreasing both the starch and fluorophore concentrations on the sensitivity and reproducibility of FACE electrophoregrams are presented. Analysis of the peak area distributions of the FACE electrophoregrams identified the labeling reaction conditions that resulted in the smallest variances in the peak area distributions while retaining strong fluorescence signals from the capillary-based DNA sequencer.

  3. Analysis of neutral surfactants by non-aqueous capillary electrophoresis using an electroosmotic flow reversal.

    Desbène, A M; Geulin, L; Morin, C J; Desbène, P L


    The separation of KM 20, that is in fact a mixture of non-ionic surfactants, was carried out by non-aqueous capillary electrophoresis. This complex mixture resulting from the condensation of ethylene oxide with fatty alcohols does not have chromophoric moieties. So, we analysed it after derivatization by means of 3,5-dinitrobenzoyl chloride. The proposed approach is based both on the formation of complexes with alkaline or ammonium cations in methanol and on the utilisation of a positively charged capillary. From a comparative study on the capillary treatment procedure, we used hexadimethrine bromide as electroosmotic flow reverser in order to obtain both repeatable analyses and good resolutions of the largest KM 20 oligomers. Then, among the five cations used to form complexes with KM 20, we pointed out that ammonium cation led to the best resolutions. Moreover, we evidenced that the counter-ion of this cation had a great influence on resolution because it modified the magnitude of electroosmotic flow. Ion pair formation that is more or less strong between ammonium and its counter-ion was involved in this variation of electroosmotic flow. So, we calculated the association constants for various ammonium salts in methanol. Then, using ammonium chloride as background electrolyte, we optimised the concentration of this salt, in methanol, in order to reach the optimal separation of KM 20 oligomers. Thus, a baseline separation was obtained by using 6 x 10(-2) mol/L NH4Cl as running electrolyte. In these conditions, we separated, in about 30 min, more than 30 oligomers of KM 20. The distribution of these oligomers that was determined from the optimal separation, appeared consistent with that obtained from HPLC analyses. Indeed, we determined that the mean ethoxylation number was equal to 18 while its real value is equal to 20.

  4. Recent progress in preparation and application of microfluidic chip electrophoresis

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao


    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast.

  5. Two-dimensional electrophoresis for comparative proteomic analysis of human bile

    Bo Chen; Jing-Qing Dong; Yong-Jun Chen; Jian-Ming Wang; Jun Tian; Chun-Ben Wang; Sheng-Quan Zou


    BACKGROUND:Proteomic analysis of bile lfuid holds promise as a method to identify biomarkers of bile tract diseases, especially for tumors. Two-dimensional electrophoresis (2-DE) is a popular and proven separation technique for proteome analysis, but using this strategy for bile lfuid analysis is still not fully developed. This study was undertaken to (a) establish a reliable method for general clean-up to make bile lfuid samples suitable for 2-DE;(b) obtain 2-D biliary maps with high reproducibility and resolution;and (c) identify protein patterns present in 2-D biliary maps for potential tumor biomarker discovery, with the intention of distinguishing malignant from benign causes of bile duct obstruction. METHODS: Bile lfuid samples were obtained from two patients suffering from malignant and benign bile tract obstruction (one patient with cholangiocarcinoma as the experimental case, the other with cholelithiasis as control). A variety of sample preparation options, including delipidation, desalination and nucleic acid removal, were adopted to remove contaminants that affect 2-DE results. After that, each 350 μg puriifed sample was loaded onto nonlinear IPG strips (18 cm, pH 3-10 and pH 4-7) for ifrst-dimension isoelectric focusing, and 12.5% SDS-PAGE electrophoresis for second dimension separation. Then 2-D maps were visualized after silver staining and analyzed with the Image Master 2-D software. RESULTS:A large number of protein spots were separated in 2-D maps from the experimental and control groups, with means of 250 and 216 spots on pH 3-10 IPG strips, and 182 and 176 spots on pH 4-7 strips, respectively. Approximately 16 and 23 spots were differentially expressed in matched pairs from the experimental and control cases using pH 3-10 and pH 4-7 strips. CONCLUSIONS: This study established a reliable sample preparation process suitable for 2-DE of bile lfuid. By this method, 2-D biliary maps with high reproducibility and resolution were obtained. The


    Wang Ming; Li Wei; Han Jinghong; Cui Dafu


    Using a standard photolithographical procedure, chemical wet etching and thermal diffusion bonding technology, a chemical analysis device for Capillary Electrophoresis(CE) has been microfabricated on a planar glass substrate with a cross-column geometry. The channels on the microchip substrate are about 50μm deep and 150μm wide. By employing amino acids derived from 2,4-DiNitroFluoroBenzen (DNFB) on CE chip channels, the sample manipulating system is studied based on the principle of electrodynamics.

  7. Capillary electrophoresis with laser-induced fluorescence: environmental applications.

    Riddick, Lee; Brumley, William C


    Capillary electrophoresis (CE), especially free-zone CE, offers a relatively simple separation with moderate selectivity based on the mobility of ions in solution. Laser-induced fluorescence (LIF) detection, an extremely sensitive technique, can be coupled with a variety of separation conditions to achieve sensitive and quantitative results. When these techniques are combined, CE/LIF provides the sensitivity and increased selectivity that makes trace level environmental analysis of fluorescent compounds possible at or below levels typical for gas chromatography (GC)/mass spectrometry (MS). We offer a panoramic review of the role of these tools in solving environmental and related analytical problems before providing a detailed experimental protocol.

  8. Capillaries for use in a multiplexed capillary electrophoresis system

    Yeung, E.S.; Chang, H.T.; Fung, E.N.


    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  9. Challenges of glycoprotein analysis by microchip capillary gel electrophoresis.

    Engel, Nicole; Weiss, Victor U; Wenz, Christian; Rüfer, Andreas; Kratzmeier, Martin; Glück, Susanne; Marchetti-Deschmann, Martina; Allmaier, Günter


    Glycosylations severely influence a protein's biological and physicochemical properties. Five exemplary proteins with varying glycan moieties were chosen to establish molecular weight (MW) determination (sizing), quantitation, and sensitivity of detection for microchip capillary gel electrophoresis (MCGE). Although sizing showed increasing deviations from literature values (SDS-PAGE or MALDI-MS) with a concomitant higher degree of analyte glycosylation, the reproducibility of MW determination and accuracy of quantitation with high sensitivity and reliability were demonstrated. Additionally, speed of analysis together with the low level of analyte consumption render MCGE attractive as an alternative to conventional SDS-PAGE. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Two-Dimensional Gel Electrophoresis: A Reference Protocol.

    Saia-Cereda, Veronica M; Aquino, Adriano; Guest, Paul C; Martins-de-Souza, Daniel


    Two-dimensional gel electrophoresis (2DE) has been a mainstay of proteomic techniques for more than four decades. It was even in use for several years before the term proteomics was actually coined in the early 1990s. Over this time, it has been used in the study of many diseases including cancer, diabetes, heart disease, and psychiatric disorders through the proteomic analysis of body fluids and tissues. This chapter presents a general protocol which can be applied in the study of biological samples such as blood serum or plasma and multiple tissues including the brain.

  11. Basics and recent advances of two dimensional- polyacrylamide gel electrophoresis


    Gel- based proteomics is one of the most versatile methods for fractionating protein complexes. Among these methods, two dimensional- polyacrylamide gel electrophoresis (2-DE) represents a mainstay orthogonal approach, which is popularly used to simultaneously fractionate, identify, and quantify proteins when coupled with mass spectrometric identification or other immunological tests. Although 2-DE was first introduced more than three decades ago, several challenges and limitations to its utility still exist. This review discusses the principles of 2-DE as well as both recent methodological advances and new applications. PMID:24735559

  12. Coupling electrokinetics and rheology: Electrophoresis in non-Newtonian fluids.

    Khair, Aditya S; Posluszny, Denise E; Walker, Lynn M


    We present a theoretical scheme to calculate the electrophoretic motion of charged colloidal particles immersed in complex (non-Newtonian) fluids possessing shear-rate-dependent viscosities. We demonstrate that this non-Newtonian rheology leads to an explicit shape and size dependence of the electrophoretic velocity of a uniformly charged particle in the thin-Debye-layer regime, in contrast to electrophoresis in Newtonian fluids. This dependence is caused by non-Newtonian stresses in the bulk (electroneutral) fluid outside the Debye layer, whose magnitude is naturally characterized in an electrophoretic Deborah number.

  13. Human muscle proteins: analysis by two-dimensional electrophoresis

    Giometti, C.S.; Danon, M.J.; Anderson, N.G.


    Proteins from single frozen sections of human muscle were separated by two-dimensional gel electrophoresis and detected by fluorography or Coomassie Blue staining. The major proteins were identical in different normal muscles obtained from either sex at different ages, and in Duchenne and myotonic dystrophy samples. Congenital myopathy denervation atrophy, polymyositis, and Becker's muscular dystrophy samples, however, showed abnormal myosin light chain compositions, some with a decrease of fast-fiber myosin light chains and others with a decrease of slow-fiber light chains. These protein alterations did not correlate with any specific disease, and may be cause by generalized muscle-fiber damage.

  14. Capillary electrophoresis: Biotechnology for separation of DNA and chromosomes

    Williams, George O., Jr.


    Electrophoresis has been used for the separation of particles, ions, and molecules for a number of years. The technology for separation and detection of the results has many applications in the life sciences. One of the major goals of the scientific community is to separate DNA molecules and intact chromosomes based upon their different lengths or number of base pairs. This may be achieved by using some of the commercially available and widely used methods, but these processes require a considerable amount of time. The challenge is to achieve separation of intact chromosomes in a short time, preferably in a matter of minutes.

  15. A New Denoising Technique for Capillary Electrophoresis Signals

    王瑛; 莫金垣


    Capillary electrophoresis(CE) is a powerful analytical tool in chemistry,Thus,it is valuable to solve the denoising of CE signals.A new denoising method called MWDA which emplosy Mexican Hat wavelet is presented ,It is an efficient chemometrics technique and has been applied successfully in processing CE signals ,Useful information can be extractred even from signals of S/N=1 .After denoising,the peak positions are unchanged and the relative errors of peak height are less than 3%.


    WangMing; LiWei; 等


    Using a standard photolithographical procedure,chenmical wet etching and thermal diffusion bonding technology,a chemical analysis device for Capillary Electrophoresis(CE) has been microfabricated on a planar glass substrate with a cross-column geometry.The channels on the microchip substrate are about 50um deep and 150um wide.By employing amino acids derived from 2,4-DiNitroFluoroBenzen(DNFB) on CE chip channels,the sample manipulating system is studied based on the principle of electrodynamics.

  17. Electrophoresis in charge-stabilized colloidal cluster phases.

    Groenewold, Jan; Zhang, Tianhui; Kegel, Willem K


    The reversible properties of cluster phases have been described by theories that invoke Coulomb interactions as a stabilizing mechanism. What is lacking so far is direct measurement of these charges. This contribution aims at predicting what to expect if electrophoresis measurements were to be performed on these systems. As a result, we get a picture that exhibits several interesting features: (1) The existence of monomers and clusters lead to distinctly different mobilities (zeta potentials) in a single sample. (2) Strong dependence of the mobilities on particle volume fraction. It is our aim that the theory outlined in this paper may serve as a guideline to interpret the expectedly "messy" electrophoretic measurements.

  18. Subtracting Technique of Baselines for Capillary Electrophoresis Signals

    WANG Ying; MO Jin-yuan; CHEN Zuan-guang; GAO Yan


    The drifting baselines of capillary electrophoresis affect the veracity of analysis greatly. This paper presents Threshold Fitting Technique(TFT) so as to subtract the baselines from the original signals and emendate the signals. In TFT, wav elet and curve fitting technique are applied synthetically, thresholds are decided by the computer automatically. Many experiments of signal processing indicate that TFT is simple for being used, there are few man-induced factors, and the results are satisfactory. TFT can be applied for noisy signals without any pre-processing.

  19. Capillary electrophoresis-electrochemical detection microchip device and supporting circuits

    Jackson, Douglas J.; Roussel, Jr., Thomas J.; Crain, Mark M.; Baldwin, Richard P.; Keynton, Robert S.; Naber, John F.; Walsh, Kevin M.; Edelen, John. G.


    The present invention is a capillary electrophoresis device, comprising a substrate; a first channel in the substrate, and having a buffer arm and a detection arm; a second channel in the substrate intersecting the first channel, and having a sample arm and a waste arm; a buffer reservoir in fluid communication with the buffer arm; a waste reservoir in fluid communication with the waste arm; a sample reservoir in fluid communication with the sample arm; and a detection reservoir in fluid communication with the detection arm. The detection arm and the buffer arm are of substantially equal length.

  20. Capillary electrophoresis coupled with electrochemiluminescence for determination of cloperastine hydrochloride


    Objective To investigate the electrochemiluminescence (ECL) behavior of cloperastine hydrochloride. Methods ECL intensity of tris (2,2′-bipyridyl) rutheniumo(Ⅱ) was enhanced, the method for the determination of cloperastine hydrochloride was established using capillary electrophoresis (CE) coupled with electrochemilumolinescence (ECL) detection. Results Under the optimum conditions, ECL intensity varied linearly with cloperastine hydrochloride concentration from 7.0×10-6g/mL to 1.0×10-4g/mL. The detection l...

  1. Separation and determination of some carboxylic acids by capillary electrophoresis

    Sladkov, V.; Fourest, B


    Separation and determination of some organic acids, mono-carboxylic (formic and acetic), dicarboxylic (oxalic and tartaric), tricarboxylic (citric) acids and aromatic acids (phtalic, benzoic, mellitic and trimellitic), by capillary electrophoresis are reviewed. The method development parameters, such as separation and injection mode, are discussed. Special attention is paid to the comparison of different detection types (spectroscopic and electrochemical). The optimisation of the carrier electrolyte composition (choice of carrier electrolyte, effect of pH, ionic strength, electro-osmotic flow modifier) is treated. Different additives (alkali-earth and transition metal ions, cyclodextrins and alcohol), which are often used for improving organic acid separation, are also considered. (authors)

  2. The fluid mechanics of continuous flow electrophoresis in perspective

    Saville, D. A.


    Buoyancy alters the flow in continuous flow electrophoresis chambers through the mechanism of hydrodynamic instability and, when the instability is supressed by careful cooling of the chamber boundaries, by restructuring the axial flow. The expanded roles of buoyancy follow upon adapting the size of the chamber and the electric field so as to fractionate certain sorts of cell populations. Scale-up problems, hydrodynamic stability and the altered flow fields are discussed to show how phenomena overlooked in the design and operations of narrow-gap devices take on an overwhelming importance in wide-gap chambers

  3. Separation and quantification of cellulases and hemicellulases by capillary electrophoresis

    Jørgensen, Henning; Kutter, Jörg Peter; Olsson, Lisbeth


    . Current methods are limited in their ability to quantify all of these enzymes when all are present simultaneously in a mixture. Five different cellulases (two cellobiohydrolases and three endoglucanases) and one hemicellulase (endoxylanase) were separated using capillary electrophoresis (CE) in a fused...... silica capillary at pH values close to neutral. The improvement of the separation of these six proteins by the addition of alpha, omega-diaminoalkanes with chain lengths from three to seven carbon units was investigated. Dynamically coating the capillary with 1,3-diaminopropane resulted in separation...

  4. Establishment and application of a new method for the determination of kinetic parameters by plug-plug kinetic capillary electrophoresis (ppKCE)

    XIONG CaiQiao; XIA ZhiNing; HUANG Rui; CHEN Hua; XU Pan


    A novel plug-plug kinetic capillary electrophoresis method was established, which can be used to si-multaneously determine the kinetic parameters kon and koff in interaction systems. The method is comparatively simple and some restrictions in conventional ppKCE methods can be effectively avoided, The requirements for resolution and detection sensitivity in this method are much lower than those of conventional ppKCE, The successful determination of the kinetic parameters and the binding constant Kb between citalopram and BSA showed availability of this method, The results were confirmed by us-ing the time ratio method. The application field of kinetic capillary electrophoresis can be expanded with this new method,

  5. Establishment and application of a new method for the determination of kinetic parameters by plug-plug kinetic capillary electrophoresis (ppKCE)


    A novel plug-plug kinetic capillary electrophoresis method was established, which can be used to si-multaneously determine the kinetic parameters kon and koff in interaction systems. The method is comparatively simple and some restrictions in conventional ppKCE methods can be effectively avoided. The requirements for resolution and detection sensitivity in this method are much lower than those of conventional ppKCE. The successful determination of the kinetic parameters and the binding constant Kb between citalopram and BSA showed availability of this method. The results were confirmed by us-ing the time ratio method. The application field of kinetic capillary electrophoresis can be expanded with this new method.

  6. Comparison of chiral recognition capabilities of cyclodextrins for the separation of basic drugs in capillary zone electrophoresis.

    Jin, L J; Li, S F


    The enantiomeric separation of some racemic anti-histamines and anti-malarials, namely (+/-)-pheniramine, (+/-)-brompheniramine, (+/-)-chlorpheniramine, (+/-)-doxylamine, and (+/-)-chloroquine, was investigated by capillary zone electrophoresis. The enantiomeric separation of five compounds was obtained by addition of approximately 7 mM (1%, w/v) sulfated-beta-cyclodextrin into the buffer as a chiral selector. The effects of sulfated-beta-cyclodextrin concentration and buffer pH on migration and resolution are discussed. Two other cyclodextrins, carboxyethylated-beta-cyclodextrin and hydroxypropyl-beta-cyclodextrin were also investigated. Four of the racemic compounds were resolved using 14 mM (2%, w/v) carboxyethylated-beta-cyclodextrin while 28 mM (4%, w/v) hydroxypropyl-beta-cyclodextrin resolved only two of them. It was found that the type of substituent and the degree of substitution on the rim of the CD structure played an important role in enhancing the chiral recognition. Cyclodextrins with negatively charged substituents and higher degree of substitution on the rim of the structure proved to give better resolution to the cationic racemic compounds compared with cyclodextrin with neutral substituents. This is due to the countercurrent mobility of the negatively charged cyclodextrin relative to the cationic analytes thus allowing for a smaller difference in interaction constants to achieve a successful resolution of enantiomers. Furthermore, lower concentrations of negatively charged cyclodextrins were necessary to achieve the equivalent resolutions as compared with the neutral ones.

  7. Technology to accelerate pangenomic scanning for unknown point mutations in exonic sequences: cycling temperature capillary electrophoresis (CTCE

    Bjørheim Jens


    Full Text Available Abstract Background Rapid means to discover and enumerate unknown mutations in the exons of human genes on a pangenomic scale are needed to discover the genes carrying inherited risk for common diseases or the genes in which somatic mutations are required for clonal diseases such as atherosclerosis and cancers. The method of constant denaturing capillary electrophoresis (CDCE permitted sensitive detection and enumeration of unknown point mutations but labor-intensive optimization procedures for each exonic sequence made it impractical for application at a pangenomic scale. Results A variant denaturing capillary electrophoresis protocol, cycling temperature capillary electrophoresis (CTCE, has eliminated the need for the laboratory optimization of separation conditions for each target sequence. Here are reported the separation of wild type mutant homoduplexes from wild type/mutant heteroduplexes for 27 randomly chosen target sequences without any laboratory optimization steps. Calculation of the equilibrium melting map of each target sequence attached to a high melting domain (clamp was sufficient to design the analyte sequence and predict the expected degree of resolution. Conclusion CTCE provides practical means for economical pangenomic detection and enumeration of point mutations in large-scale human case/control cohort studies. We estimate that the combined reagent, instrumentation and labor costs for scanning the ~250,000 exons and splice sites of the ~25,000 human protein-coding genes using automated CTCE instruments in 100 case cohorts of 10,000 individuals each are now less than U.S. $500 million, less than U.S. $500 per person.

  8. BioMEMS and Electrophoresis in 2006: Review of the 23rd Annual Meeting of the American Electrophoresis Society.

    Minerick, Adrienne R; Ugaz, Victor M


    The 23rd Annual Meeting of the American Electrophoresis Society (AES) was held at the San Francisco Hilton in San Francisco, California on 12-17 November 2006. This year's meeting featured a look toward the future, with an emphasis on theoretical and experimental advances in miniaturization of BioMEMS, electrokinetics, and proteomics technologies. A total of 13 sessions accommodating 71 presentations and 18 posters were held in conjunction with the Annual Meeting of the American Institute of Chemical Engineers (AIChE). This review and corresponding special issue of Biomicrofluidics provide a sampling of some of the exciting research presented at the conference.

  9. Development of coatings to control electroosmosis in zero gravity electrophoresis

    Krupnick, A. C.


    A major problem confronting the operation of free fluid electrophoresis in zero gravity is the control of electrokinetic phenomena and, in particular, electroosmosis. Due to the severity of counter flow, as a result of electroosmosis, the electrical potential developed at the surface of shear must be maintained at near, or as close to, zero millivolts as possible. Based upon this investigation, it has been found that the amount of bound water or the degree of hydroxylation plays a major role in the control of this phenomena. Of necessity, factors, such as adhesion, biocompatibility, protein adsorption, and insolubility were considered in this investigation because of the long buffer-coating exposure times required by present space operations. Based upon tests employing microcapillary electrophoresis, it has been found that gamma amino propyl trihydroxysilane produced a coating which provides the lowest potential (minus 3.86 mv) at the surface of shear between the stationary and mobile layers. This coating has been soaked in both borate and saline buffers, up to three months, in a pH range of 6.5 to 10 without deleterious effects or a change in its ability to control electrokinetic effects.

  10. Molecular transport in collagenous tissues measured by gel electrophoresis.

    Hunckler, Michael D; Tilley, Jennifer M R; Roeder, Ryan K


    Molecular transport in tissues is important for drug delivery, nutrient supply, waste removal, cell signaling, and detecting tissue degeneration. Therefore, the objective of this study was to investigate gel electrophoresis as a simple method to measure molecular transport in collagenous tissues. The electrophoretic mobility of charged molecules in tissue samples was measured from relative differences in the velocity of a cationic dye passing through an agarose gel in the absence and presence of a tissue section embedded within the gel. Differences in electrophoretic mobility were measured for the transport of a molecule through different tissues and tissue anisotropy, or the transport of different sized molecules through the same tissue. Tissue samples included tendon and fibrocartilage from the proximal (tensile) and distal (compressive) regions of the bovine flexor tendon, respectively, and bovine articular cartilage. The measured electrophoretic mobility was greatest in the compressive region of the tendon (fibrocartilage), followed by the tensile region of tendon, and lowest in articular cartilage, reflecting differences in the composition and organization of the tissues. The anisotropy of tendon was measured by greater electrophoretic mobility parallel compared with perpendicular to the predominate collagen fiber orientation. Electrophoretic mobility also decreased with increased molecular size, as expected. Therefore, the results of this study suggest that gel electrophoresis may be a useful method to measure differences in molecular transport within various tissues, including the effects of tissue type, tissue anisotropy, and molecular size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Two-Dimensional Gel Electrophoresis and 2D-DIGE.

    Meleady, Paula


    Two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) continues to be one of the most versatile and widely used techniques to study the proteome of a biological system. In particular, a modified version of 2D-PAGE, two-dimensional difference gel electrophoresis (2D-DIGE), which uses differential labeling of protein samples with up to three fluorescent tags, offers greater sensitivity and reproducibility over conventional 2D-PAGE gels for differential quantitative analysis of protein expression between experimental groups. Both these methods have distinct advantages in the separation and identification of thousands of individual proteins species including protein isoforms and post-translational modifications. This review will discuss the principles of 2D-PAGE and 2D-DIGE including limitations to the methods. 2D-PAGE and 2D-DIGE continue to be popular methods in bioprocessing-related research (particularly on recombinant Chinese hamster ovary cells), which will also be discussed in the review chapter.

  12. Startup of electrophoresis in a suspension of colloidal spheres.

    Chiang, Chia C; Keh, Huan J


    The transient electrophoretic response of a homogeneous suspension of spherical particles to the step application of an electric field is analyzed. The electric double layer encompassing each particle is assumed to be thin but finite, and the effect of dynamic electroosmosis within it is incorporated. The momentum equation for the fluid outside the double layers is solved through the use of a unit cell model. Closed-form formulas for the time-evolving electrophoretic and settling velocities of the particles in the Laplace transform are obtained in terms of the electrokinetic radius, relative mass density, and volume fraction of the particles. The time scale for the development of electrophoresis and sedimentation is significantly smaller for a suspension with a higher particle volume fraction or a smaller particle-to-fluid density ratio, and the electrophoretic mobility at any instant increases with an increase in the electrokinetic particle radius. The transient electrophoretic mobility is a decreasing function of the particle volume fraction if the particle-to-fluid density ratio is relatively small, but it may increase with an increase in the particle volume fraction if this density ratio is relatively large. The particle interaction effect in a suspension on the transient electrophoresis is much weaker than that on the transient sedimentation of the particles.

  13. Online comprehensive two-dimensional ion chromatography × capillary electrophoresis.

    Ranjbar, Leila; Gaudry, Adam J; Breadmore, Michael C; Shellie, Robert A


    A comprehensively coupled online two-dimensional ion chromatography-capillary electrophoresis (IC × CE) system for quantitative analysis of inorganic anions and organic acids in water is introduced. The system employs an in-house built sequential injection-capillary electrophoresis instrument and a nonfocusing modulation interface comprising a tee-piece and a six-port two-position injection valve that allows comprehensive sampling of the IC effluent. High field strength (+2 kV/cm) enables rapid second-dimension separations in which each peak eluted from the first-dimension separation column is analyzed at least three times in the second dimension. The IC × CE approach has been successfully used to resolve a suite of haloacetic acids, dalapon, and common inorganic anions. Two-dimensional peak capacity for IC × CE was 498 with a peak production rate of 9 peaks/min. Linear calibration curves were obtained for all analytes from 5 to 225 ng/mL (except dibromoacetic acid (10-225 ng/mL) and tribromoacetic acid (25-225 ng/mL)). The developed approach was used to analyze a spiked tap water sample, with good measured recoveries (69-119%).

  14. Proteomic study of muscle sarcoplasmic proteins using AUT-PAGE/SDS-PAGE as two-dimensional gel electrophoresis.

    Picariello, Gianluca; De Martino, Alessandra; Mamone, Gianfranco; Ferranti, Pasquale; Addeo, Francesco; Faccia, Michele; Spagnamusso, Salvatore; Di Luccia, Aldo


    In the present study, an alternative procedure for two-dimensional (2D) electrophoretic analysis in proteomic investigation of the most represented basic muscle water-soluble proteins is suggested. Our method consists of Acetic acid-Urea-Triton polyacrylamide gel (AUT-PAGE) analysis in the first dimension and standard sodium dodecyl sulphate polyacrylamide gel (SDS-PAGE) in the second dimension. Although standard two-dimensional Immobilized pH Gradient-Sodium Dodecyl-Sulphate (2D IPG-SDS) gel electrophoresis has been successfully used to study these proteins, most of the water-soluble proteins are spread on the alkaline part of the 2D map and are poorly focused. Furthermore, the similarity in their molecular weights impairs resolution of the classical approach. The addition of Triton X-100, a non-ionic detergent, into the gel induces a differential electrophoretic mobility of proteins as a result of the formation of mixed micelles between the detergent and the hydrophobic moieties of polypeptides, separating basic proteins with a criterion similar to reversed phase chromatography based on their hydrophobicity. The acid pH induces positive net charges, increasing with the isoelectric point of proteins, thus allowing enhanced resolution in the separation. By using 2D AUT-PAGE/SDS electrophoresis approach to separate water-soluble proteins from fresh pork and from dry-cured products, we could spread proteins over a greater area, achieving a greater resolution than that obtained by IPG in the pH range 3-10 and 6-11. Sarcoplasmic proteins undergoing proteolysis during the ripening of products were identified by Matrix Assisted Laser Desorption/Ionization-Time of Flight (MALDI-ToF) mass spectrometry peptide mass fingerprinting in a easier and more effective way. Two-dimensional AUT-PAGE/SDS electrophoresis has allowed to simplify separation of sarcoplasmic protein mixtures making this technique suitable in the defining of quality of dry-cured pork products by immediate

  15. An experimental design based strategy to optimize a capillary electrophoresis method for the separation of 19 polycyclic aromatic hydrocarbons.

    Ferey, Ludivine; Delaunay, Nathalie; Rutledge, Douglas N; Huertas, Alain; Raoul, Yann; Gareil, Pierre; Vial, Jérôme; Rivals, Isabelle


    Because of their high toxicity, international regulatory institutions recommend monitoring specific polycyclic aromatic hydrocarbons (PAHs) in environmental and food samples. A fast, selective and sensitive method is therefore required for their quantitation in such complex samples. This article deals with the optimization, based on an experimental design strategy, of a cyclodextrin (CD) modified capillary zone electrophoresis separation method for the simultaneous separation of 19 PAHs listed as priority pollutants. First, using a central composite design, the normalized peak-start and peak-end times were modelled as functions of the factors that most affect PAH electrophoretic behavior: the concentrations of the anionic sulfobutylether-β-CD and neutral methyl-β-CD, and the percentage of MeOH in the background electrolyte. Then, to circumvent computational difficulties resulting from the changes in migration order likely to occur while varying experimental conditions, an original approach based on the systematic evaluation of the time intervals between all the possible pairs of peaks was used. Finally, a desirability analysis based on the smallest time interval between two consecutive peaks and on the overall analysis time, allowed us to achieve, for the first time in CE, full resolution of all 19 PAHs in less than 18 min. Using this optimized capillary electrophoresis method, a vegetable oil was successfully analyzed, proving its suitability for real complex sample analysis.

  16. Microalgae amino acid extraction and analysis at nanomolar level using electroporation and capillary electrophoresis with laser-induced fluorescence detection.

    Nehmé, Reine; Atieh, Carla; Fayad, Syntia; Claude, Bérengère; Chartier, Agnès; Tannoury, Mona; Elleuch, Fatma; Abdelkafi, Slim; Pichon, Chantal; Morin, Philippe


    Amino acids play a key role in food analysis, clinical diagnostics, and biochemical research. Capillary electrophoresis with laser-induced fluorescence detection was used for the analysis of several amino acids. Amino acid labeling with fluorescein isothiocyanate was conducted using microwave-assisted derivatization at 80°C (680 W) during only 150 s. Good electrophoretic resolution was obtained using a background electrolyte composed of sodium tetraborate buffer (100 mM; pH 9.4) and β-cyclodextrin (10 mM), and the limits of quantification were 3-30 nM. The developed capillary electrophoresis with laser-induced fluorescence method was used to analyze amino acids in Dunaliella salina green algae grown under different conditions. A simple extraction technique based on electroporation of the cell membrane was introduced. A home-made apparatus allowed the application of direct and alternating voltages across the electrochemical compartment containing a suspension of microalgae in distilled water at 2.5 g/L. A direct voltage of 12 V applied for 4 min gave the optimum extraction yield. Results were comparable to those obtained with accelerated-solvent extraction. The efficiency of electroporation in destroying microalgae membranes was shown by examining the algae surface morphology using scanning electron microscopy. Stress conditions were found to induce the production of amino acids in Dunaliella salina cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Ultra-high voltage capillary electrophoresis >300 kV: recent advances in instrumentation and analyte detection.

    Henley, W Hampton; Jorgenson, James W


    Instrumentation has been developed for the implementation of ultra-high voltage capillary electrophoresis (UHVCE) with potentials up to and exceeding 300 kV. Several separations have been used to demonstrate the utility of higher applied voltages for improving the resolution of peptide, protein, and nucleic acid separations. Previously reported instrumentation was limited to 120 kV and required submersion in a bath of transformer oil to prevent corona and high voltage arcing between the components of the instrument [Hutterer, 1999, 2000, 2005] [1-3]. A modular design that uses plastic dielectric materials to overcome these obstacles enabling simplified operation of the instrument in air is described here in detail. A forced air system developed to control the temperature of the instrument to within a few degrees over a range of 25-60 °C for use with ultra-high voltage capillary gel electrophoresis is also described. UHVCE instrumentation and its applications with UV absorption and laser induced fluorescence detection are further developed, and the first demonstration of UHVCE coupled to electrospray ionization-mass spectrometry is shown. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Optimizing separation conditions of 19 polycyclic aromatic hydrocarbons by cyclodextrin-modified capillary electrophoresis and applications to edible oils.

    Ferey, Ludivine; Delaunay, Nathalie; Rutledge, Douglas N; Cordella, Christophe B Y; This, Hervé; Huertas, Alain; Raoul, Yann; Gareil, Pierre


    For the first time, the separation of 19 polycyclic aromatic hydrocarbons (PAHs) listed as priority pollutants in environmental and food samples by the United States Environmental Protection Agency (US-EPA) and the European Food Safety Authority was developed in cyclodextrin (CD)-modified capillary zone electrophoresis with laser-induced fluorescence detection (excitation wavelength: 325 nm). The use of a dual CD system, involving a mixture of one neutral CD and one anionic CD, enabled to reach unique selectivity. As solutes were separated based on their differential partitioning between the two CDs, the CD relative concentrations were investigated to optimize selectivity. Separation of 19 PAHs with enhanced resolutions as compared with previous studies on the 16 US-EPA PAHs and efficiencies superior to 1.5 × 10(5) were achieved in 15 min using 10mM sulfobutyl ether-β-CD and 20mM methyl-β-CD. The use of an internal standard (umbelliferone) with appropriate electrolyte and sample compositions, rinse sequences and sample vial material resulted in a significant improvement in method repeatability. Typical RSD variations for 6 successive experiments were between 0.8% and 1.7% for peak migration times and between 1.2% and 4.9% for normalized corrected peak areas. LOQs in the low µg/L range were obtained. For the first time in capillary electrophoresis, applications to real vegetable oil extracts were successfully carried out using the separation method developed here.

  19. Human genomic DNA analysis using a semi-automated sample preparation, amplification, and electrophoresis separation platform.

    Raisi, Fariba; Blizard, Benjamin A; Raissi Shabari, Akbar; Ching, Jesus; Kintz, Gregory J; Mitchell, Jim; Lemoff, Asuncion; Taylor, Mike T; Weir, Fred; Western, Linda; Wong, Wendy; Joshi, Rekha; Howland, Pamela; Chauhan, Avinash; Nguyen, Peter; Petersen, Kurt E


    The growing importance of analyzing the human genome to detect hereditary and infectious diseases associated with specific DNA sequences has motivated us to develop automated devices to integrate sample preparation, real-time PCR, and microchannel electrophoresis (MCE). In this report, we present results from an optimized compact system capable of processing a raw sample of blood, extracting the DNA, and performing a multiplexed PCR reaction. Finally, an innovative electrophoretic separation was performed on the post-PCR products using a unique MCE system. The sample preparation system extracted and lysed white blood cells (WBC) from whole blood, producing DNA of sufficient quantity and quality for a polymerase chain reaction (PCR). Separation of multiple amplicons was achieved in a microfabricated channel 30 microm x 100 microm in cross section and 85 mm in length filled with a replaceable methyl cellulose matrix operated under denaturing conditions at 50 degrees C. By incorporating fluorescent-labeled primers in the PCR, the amplicons were identified by a two-color (multiplexed) fluorescence detection system. Two base-pair resolution of single-stranded DNA (PCR products) was achieved. We believe that this integrated system provides a unique solution for DNA analysis.

  20. Optimization of Protein Extraction and Two-Dimensional Electrophoresis Protocols for Oil Palm Leaf.

    Daim, Leona Daniela Jeffery; Ooi, Tony Eng Keong; Yusof, Hirzun Mohd; Majid, Nazia Abdul; Karsani, Saiful Anuar Bin


    Oil palm (Elaeis guineensis) is an important economic crop cultivated for its nutritional palm oil. A significant amount of effort has been undertaken to understand oil palm growth and physiology at the molecular level, particularly in genomics and transcriptomics. Recently, proteomics studies have begun to garner interest. However, this effort is impeded by technical challenges. Plant sample preparation for proteomics analysis is plagued with technical challenges due to the presence of polysaccharides, secondary metabolites and other interfering compounds. Although protein extraction methods for plant tissues exist, none work universally on all sample types. Therefore, this study aims to compare and optimize different protein extraction protocols for use with two-dimensional gel electrophoresis of young and mature leaves from the oil palm. Four protein extraction methods were evaluated: phenol-guanidine isothiocyanate, trichloroacetic acid-acetone precipitation, sucrose and trichloroacetic acid-acetone-phenol. Of these four protocols, the trichloroacetic acid-acetone-phenol method was found to give the highest resolution and most reproducible gel. The results from this study can be used in sample preparations of oil palm tissue for proteomics work.

  1. Analysis of Differential Gel Electrophoresis of Paclitaxol Resistant and Sensitive Lung Adenocarcinoma Cells' Secretome

    Tianqing CHU


    Full Text Available Background and objective Paclitaxol (PTX resistance is one of main factors which affect the outcome of chemotherapy of lung adenocarcinoma. The aim of this study is to compare the secreted protein expression profiles between Paclitaxol (PTX resistant and sensitive lung adenocarcinoma cells by proteomic research method, so as to provide evidence of choosing individual chemotherapy drugs in clinical treatment. Methods Total secreted proteins extracted from a PTX sensitive cell line A549 and a PTX resistant cell line A549-Taxol were separated by fluorscent differential gel electrophoresis (DIGE. High quality 2-DE profiles were obtained and analyzed by Decyder 6.5 analysis software to screen differentially expressed protein spots. Those spots were identified by mass spectrometry. Results 2-DE patterns of lung adenocarcinoma cells with high-resolution and reproducibility were obtained. 76 significantly differentially expressed protein spots were screened, 19 proteins were identified by mass spectrometry. The identified proteins could be classified into different catogories: metabolic enzyme, extracellular matrix (ECM degradation enzyme, cytokine, signal transducer, cell adhesion, and so on. Conclusion Multiple secreted proteins related to chemoresistance of A549-Taxol cells were identified in this study for the first time. The results presented here would provide clues to identify new serologic chemoresistant biomarkers of NSCLC.

  2. Evaluation of the electroosmotic medium pump system for preparative disk gel electrophoresis.

    Hayakawa, M; Hosogi, Y; Takiguchi, H; Saito, S; Shiroza, T; Shibata, Y; Hiratsuka, K; Kiyama-Kishikawa, M; Abiko, Y


    This paper describes an improved electroosmotic elution system for preparative sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) based on the epochal idea of H. V. Tan et al. (Nucleic Acids Res. 1988, 16, 1921-1930). In this elution system, a semipermeable membrane, mounted under the gel terminal end, works as the elution pump as well as the partition of the elution chamber. We refer to this system as the "electroosmotic medium pump system." Operation of the constructed apparatus (3.6 cm i.d. disk gel column) and resolution of the protein bands were examined by separation of the model protein mixture (bovine serum albumin (BSA), ovalbumin, bovine carbonic anhydrase, soybean trypsin inhibitor) and purification of the membrane protein, dipeptidyl peptidase IV (DPP IV). The Spectra/Por 7 dialysis membrane provided a better flow profile for the elution buffer. The four model proteins of the protein mixture were able to be completely separated from each other and recovered without dilution. The maximum protein concentration of eluate achieved was 93 mg/ml, when applying a single component, BSA fraction V, as a sample. Furthermore, the multifunctional ectoenzyme, DPP IV, was purified in a single step.

  3. Fast analysis of glibenclamide and its impurities: quality by design framework in capillary electrophoresis method development.

    Furlanetto, Sandra; Orlandini, Serena; Pasquini, Benedetta; Caprini, Claudia; Mura, Paola; Pinzauti, Sergio


    A fast capillary zone electrophoresis method for the simultaneous analysis of glibenclamide and its impurities (I(A) and I(B)) in pharmaceutical dosage forms was fully developed within a quality by design framework. Critical quality attributes were represented by I(A) peak efficiency, critical resolution between glibenclamide and I(B), and analysis time. Experimental design was efficiently used for rapid and systematic method optimization. A 3(5)//16 symmetric screening matrix was chosen for investigation of the five selected critical process parameters throughout the knowledge space, and the results obtained were the basis for the planning of the subsequent response surface study. A Box-Behnken design for three factors allowed the contour plots to be drawn and the design space to be identified by introduction of the concept of probability. The design space corresponded to the multidimensional region where all the critical quality attributes reached the desired values with a degree of probability π ≥ 90%. Under the selected working conditions, the full separation of the analytes was obtained in less than 2 min. A full factorial design simultaneously allowed the design space to be validated and method robustness to be tested. A control strategy was finally implemented by means of a system suitability test. The method was fully validated and was applied to real samples of glibenclamide tablets.

  4. Enantiodifferentiation of chiral baclofen by β-cyclodextrin using capillary electrophoresis: A molecular modeling approach

    Suliman, FakhrEldin O.; Elbashir, Abdalla A.


    Using capillary electrophoresis baclofen (BF) enantiomers were separated only in the presence of β-cyclodextrin (βCD) as a chiral selector when added to the background electrolyte. Proton nuclear magnetic resonance and electrospray ionization mass spectrometry (ESI-MS) techniques were used to determine the structure of the BF-βCD inclusion complexes. From the MS data BF was found to form a 1:1 complex with α- and βCD, while the NMR data suggest location of the aromatic ring of BF into the cyclodextrin cavity. A molecular modeling study, using the semiempirical PM6 calculations was used to investigate the mechanism of enantiodifferentiation of BF with cyclodextrins. Optimization of the structures of the complexes by PM6 method indicated that separation is obtained in the presence of β-CD due to a large binding energy difference (ΔΔE) of 46.8 kJ mol-1 between S-BF-βCD and R-BF-βCD complexes. In the case of αCD complexes ΔΔE was 1.3 kJ mol-1 indicating poor resolution between the two enantiomers. Furthermore, molecular dynamic simulations show that the formation of more stable S-BF-βCD complex compared to R-BF-β-CD complex is primarily due to differences in intermolecular hydrogen bonding.

  5. Monitoring exocytosis and release from individual mast cells by capillary electrophoresis and UV imaging microscopy

    Yeung, E.S. [Ames Lab., IA (United States)]|[Iowa State Univ., Ames, IA (United States); Lillard, S.J. [Stanford Univ., CA (United States); McCloskey, M.A. [Iowa State Univ., Ames, IA (United States)


    The complex temporal evolution of on-column exocytotic release of serotonin from individual peritoneal mast cells (RPMCs) was monitored by using capillary electrophoresis and UV imaging microscopy. Laser-induced native fluorescence detection with 275-nm excitation was used, and a detection limit of 1.7 amol (S/N = 3; rms) was obtained for serotonin. A physiological running buffer was used to ensure that the cell remained viable throughout. The secretagogue was polymyxin B sulfate (Pmx). Following the injection of a single mast cell into the capillary, electromigration of Pmx toward and past the cell induced degranulation and release of serotonin. The time course of release was registered in the electropherograms with subsecond resolution. Subsequent introduction of SDS caused the cell to lyse completely and allowed the residual serotonin to be quantified. The average amount of serotonin observed per RPMC was 1.6 {+-} 0.6 fmol; the average percentage of serotonin released was 28 {+-} 14%. Events that are consistent with released serontonin from single submicron granules (250 aL each) were evident, each of which contained an average amount of 5.9 {+-} 3 amol. Alternatively, UV movies can be taken of the entire event to provide temporal and spatial information.

  6. Screening for TP53 mutations in osteosarcomas using constant denaturant gel electrophoresis (CDGE).

    Smith-Sørensen, B; Gebhardt, M C; Kloen, P; McIntyre, J; Aguilar, F; Cerutti, P; Børresen, A L


    We have previously developed conditions to screen for TP53 point mutations inside the conserved domains II-V of the gene by using constant denaturant gel electrophoresis (CDGE). The present study reports conditions for screening more of the codons in the frequently mutated region exon 5-8 and for detecting mutations in sequences encoding functional domains in the N- and C-terminal part of the protein. The ability of the CDGE technique to detect mutations was studied using controls with known sequence deviations. The resolution power of the technique to separate different types of mutations was tested by using seven different single base pair mutants all residing in a stretch of four base pairs. All mutants were separated from the wild type. The established CDGE screening strategy was then used to look for mutations in DNA from 28 osteosarcomas. Six (21.5%) of the samples were shown to have a TP53 mutation, and the exact characterization was performed by direct sequencing. All of these were within the frequently reported mutated region exon 5-8.

  7. Development of a polymer-based easy-to-fabricate micro-free-flow electrophoresis device

    Akagi, Takanori; Kubota, Ryosuke; Kobayashi, Masashi; Ichiki, Takanori


    Since 1990s, micro-free-flow electrophoresis (µFFE) devices have been developed to allow for smaller sample volume and reagent consumption. To solve several technical problems involving the generation of electrolysis gas on the electrodes, most of the µFFE devices reported in the past were fabricated using elaborate micromachining process on silicon or glass substrates. However, high-cost micromachining processes were required and these were not suitable for mass production. In this paper, we report a polymer-based easy-to-fabricate µFFE device using a poly(methyl methacrylate-co-styrene), P(MMA-co-S), substrate and tetra-PEG gel for preventing the invasion of electrolysis gas into the separation chamber. In the separation experiment using a mixture of rhodamine B and sulforhodamine B, the resolution increased linearly with the increase of the applied voltages up to 50 V, whereas a deviation from the linear relation was observed above 50 V, which is possibly the Joule heating. These results indicate that this device could be applicable to separation of biological samples.

  8. Quality criterion to optimize separations in capillary electrophoresis: Application to the analysis of harmala alkaloids.

    Tascon, Marcos; Benavente, Fernando; Castells, Cecilia B; Gagliardi, Leonardo G


    In capillary electrophoresis (CE), resolution (Rs) and selectivity (α) are criteria often used in practice to optimize separations. Nevertheless, when these and other proposed parameters are considered as an elementary criterion for optimization by mathematical maximization, certain issues and inconsistencies appear. In the present work we analyzed the pros and cons of using these parameters as elementary criteria for mathematical optimization of capillary electrophoretic separations. We characterized the requirements of an ideal criterion to qualify separations within the framework of mathematical optimizations and, accordingly, propose: -1- a new elementary criterion (t') and -2- a method to extend this elementary criterion to compose a global function that simultaneously qualifies many different aspects, also called multicriteria optimization function (MCOF). In order to demonstrate this new concept, we employed a group of six alkaloids with closely related structures (harmine, harmaline, harmol, harmalol, harmane and norharmane). On the basis of this system, we present a critical comparison between the new optimization criterion t' and the former elementary criteria. Finally, aimed at validating the proposed methods, we composed an MCOF in which the capillary-electrophoretic separation of the six model compounds is mathematically optimized as a function of pH as the unique variable. Experimental results subsequently confirmed the accuracy of the model.

  9. Capillary Electrophoresis-Mass Spectrometry for the Analysis of Heparin Oligosaccharides and Low Molecular Weight Heparin.

    Sun, Xiaojun; Lin, Lei; Liu, Xinyue; Zhang, Fuming; Chi, Lianli; Xia, Qiangwei; Linhardt, Robert J


    Heparins, highly sulfated, linear polysaccharides also known as glycosaminoglycans, are among the most challenging biopolymers to analyze. Hyphenated techniques in conjunction with mass spectrometry (MS) offer rapid analysis of complex glycosaminoglycan mixtures, providing detailed structural and quantitative data. Previous analytical approaches have often relied on liquid chromatography (LC)-MS, and some have limitations including long separation times, low resolution of oligosaccharide mixtures, incompatibility of eluents, and often require oligosaccharide derivatization. This study examines the analysis of glycosaminoglycan oligosaccharides using a novel electrokinetic pump-based capillary electrophoresis (CE)-MS interface. CE separation and electrospray were optimized using a volatile ammonium bicarbonate electrolyte and a methanol-formic acid sheath fluid. The online analyses of highly sulfated heparin oligosaccharides, ranging from disaccharides to low molecular weight heparins, were performed within a 10 min time frame, offering an opportunity for higher-throughput analysis. Disaccharide compositional analysis as well as top-down analysis of low molecular weight heparin was demonstrated. Using normal polarity CE separation and positive-ion electrospray ionization MS, excellent run-to-run reproducibility (relative standard deviation of 3.6-5.1% for peak area and 0.2-0.4% for peak migration time) and sensitivity (limit of quantification of 2.0-5.9 ng/mL and limit of detection of 0.6-1.8 ng/mL) could be achieved.

  10. Analysis of Three Compounds in Flos Farfarae by Capillary Electrophoresis with Large-Volume Sample Stacking

    Hai-xia Yu


    Full Text Available The aim of this study was to develop a method combining an online concentration and high-efficiency capillary electrophoresis separation to analyze and detect three compounds (rutin, hyperoside, and chlorogenic acid in Flos Farfarae. In order to get good resolution and enrichment, several parameters such as the choice of running buffer, pH and concentration of the running buffer, organic modifier, temperature, and separation voltage were all investigated. The optimized conditions were obtained as follows: the buffer of 40 mM NaH2P04-40 mM Borax-30% v/v methanol (pH 9.0; the sample hydrodynamic injection of up to 4 s at 0.5 psi; 20 kV applied voltage. The diode-array detector was used, and the detection wavelength was 364 nm. Based on peak area, higher levels of selective and sensitive improvements in analysis were observed and about 14-, 26-, and 5-fold enrichment of rutin, hyperoside, and chlorogenic acid were achieved, respectively. This method was successfully applied to determine the three compounds in Flos Farfarae. The linear curve of peak response versus concentration was from 20 to 400 µg/ml, 16.5 to 330 µg/mL, and 25 to 500 µg/mL, respectively. The regression coefficients were 0.9998, 0.9999, and 0.9991, respectively.

  11. High-speed DNA genotyping using microfabricated capillary array electrophoresis chips

    Woolley, A.T.; Sensabaugh, G.F.; Mathies, R.A. [Univ. of California, Berkeley, CA (United States)


    Capillary array electrophoresis (CAE) chips have been designed and fabricated with the capacity to rapidly (<160 s) analyze 12 different samples in parallel. Detection of all lanes with 0.3 s temporal resolution was achieved using a laser-excited confocal-fluorescence scanner. The operation and capabilities of these CAE microdevices were first determined by performing electrophoretic separations of pBR322 MspI DNA samples. Genotyping of HLA-H, a candidate gene for the diagnosis of hereditary hemochromatosis, was then performed to demonstrate the rapid analysis of biologically relevant samples. Two-color multiplex fluorescence detection of HLA-H genotypes was accomplished by prelabeling the standard pBR322 MspI DNA ladder with a red emitting bisintercalation dye (butyl TOTIN) and on-column labeling of the HLA-H DNA with thiazole orange. This work establishes the feasibility of using CAE chips for high-speed, high-throughput genotyping. 44 refs., 7 figs.

  12. CN-GELFrEE - Clear Native Gel-eluted Liquid Fraction Entrapment Electrophoresis.

    Melani, Rafael D; Seckler, Henrique S; Skinner, Owen S; Do Vale, Luis H F; Catherman, Adam D; Havugimana, Pierre C; Valle de Sousa, Marcelo; Domont, Gilberto B; Kelleher, Neil L; Compton, Philip D


    Protein complexes perform an array of crucial cellular functions. Elucidating their non-covalent interactions and dynamics is paramount for understanding the role of complexes in biological systems. While the direct characterization of biomolecular assemblies has become increasingly important in recent years, native fractionation techniques that are compatible with downstream analysis techniques, including mass spectrometry, are necessary to further expand these studies. Nevertheless, the field lacks a high-throughput, wide-range, high-recovery separation method for native protein assemblies. Here, we present clear native gel-eluted liquid fraction entrapment electrophoresis (CN-GELFrEE), which is a novel separation modality for non-covalent protein assemblies. CN-GELFrEE separation performance was demonstrated by fractionating complexes extracted from mouse heart. Fractions were collected over 2 hr and displayed discrete bands ranging from ~30 to 500 kDa. A consistent pattern of increasing molecular weight bandwidths was observed, each ranging ~100 kDa. Further, subsequent reanalysis of native fractions via SDS-PAGE showed molecular-weight shifts consistent with the denaturation of protein complexes. Therefore, CN-GELFrEE was proved to offer the ability to perform high-resolution and high-recovery native separations on protein complexes from a large molecular weight range, providing fractions that are compatible with downstream protein analyses.

  13. Molecular Analysis of Mycobacterium avium Isolates by Using Pulsed-Field Gel Electrophoresis and PCR

    Pestel-Caron, Martine; Graff, Gabriel; Berthelot, Gilles; Pons, Jean-Louis; Lemeland, Jean-François


    Genetic relationships among 46 isolates of Mycobacterium avium recovered from 37 patients in a 2,500-bed hospital from 1993 to 1998 were assessed by pulsed-field gel electrophoresis (PFGE) and PCR amplification of genomic sequences located between the repetitive elements IS1245 and IS1311. Each technique enabled the identification of 27 to 32 different patterns among the 46 isolates, confirming that the genetic heterogeneity of M. avium strains is high in a given community. Furthermore, this retrospective analysis of sporadic isolates allowed us (i) to suggest the existence of two remanent strains in our region, (ii) to raise the question of the possibility of nosocomial acquisition of M. avium strains, and (iii) to document laboratory contamination. The methods applied in the present study were found to be useful for the typing of M. avium isolates. In general, both methods yielded similar results for both related and unrelated isolates. However, the isolates in five of the six PCR clusters were distributed among two to three PFGE patterns, suggesting that this PCR-based method may have limitations for the analysis of strains with low insertion sequence copy numbers or for resolution of extended epidemiologic relationships. PMID:10405383

  14. Serial displacement chromatofocusing and its applications in multidimensional chromatography and gel electrophoresis: II. Experimental results.

    Shen, Hong; Li, Xiang; Bieberich, Charles; Frey, Douglas D


    Part I of this study investigated the theory and basic characteristics of "serial displacement chromatofocusing" (SDC). In Part II of this study, SDC is applied to two prototype applications which have potential uses in proteomics and related areas involving the analysis of complex analyte mixtures. In the first application, SDC was used as a prefractionation method prior to two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) to separate a human prostate cancer cell lysate. It was observed that the resolution achieved in narrow-pI-range 2D-PAGE was improved when using SDC prefractionation, so that SDC may be useful as a low-cost, high-speed, and highly scalable alternative to electrophoretic prefractionation methods for 2D-PAGE. The second application involves the use of SDC as the first dimension, and reversed-phase chromatography as the second dimension, to produce a novel, fully automated, two-dimensional high-performance liquid chromatography technique. The method was shown to have performance advantages over one-dimensional reversed-phase chromatography for peptide separations.

  15. Chemometrics optimization of six antihistamines separations by capillary electrophoresis with electrochemiluminescence detection.

    Zhu, Derong; Li, Xia; Sun, Jinying; You, Tianyan


    This work expanded the knowledge of the use of chemometric experimental design in optimizing of six antihistamines separations by capillary electrophoresis with electrochemiluminescence detection. Specially, central composite design was employed for optimizing the three critical electrophoretic variables (Tris-H(3)PO(4) buffer concentration, buffer pH value and separation voltage) using the chromatography resolution statistic function (CRS function) as the response variable. The optimum conditions were established from empirical model: 24.2mM Tris-H(3)PO(4) buffer (pH 2.7) with separation voltage of 15.9 kV. Applying theses conditions, the six antihistamines (carbinoxamine, chlorpheniramine, cyproheptadine, doxylamine, diphenhydramine and ephedrine) could be simultaneous separated in less than 22 min. Our results indicate that the chemometrics optimization method can greatly simplify the optimization procedure for multi-component analysis. The proposed method was also validated for linearity, repeatability and sensitivity, and was successfully applied to determine these antihistamine drugs in urine.

  16. Capillary electrophoresis in the evaluation of ischemic injury: simultaneous determination of purine compounds and glutathione.

    Carlucci, F; Tabucchi, A; Biagioli, B; Sani, G; Lisi, G; Maccherini, M; Rosi, F; Marinello, E


    An understanding of tissue energy metabolism and antioxidant status is of major interest in the field of organ preservation for transplantation. Nucleotide and glutathione are indicators of cell damage occurring during ischemia and reperfusion. A high performance capillary electrophoresis (HPCE) method with UV detection (185 nm) for the simultaneous analysis of intracellular free ribonucleotides, nucleosides, bases and glutathione (oxidized and reduced form) in myocardial tissues is described. The method does not involve thiol derivatization. The separations were carried out in an uncoated fused-silica capillary, 60 cm long, 52.5 cm to detector, 75 microm ID, with 20 mM Na-borate buffer, pH 10.00, at 20 kV voltage and reading at 185 nm. Injection was hydrostatic for 12 s and total analysis time was 20 min. The technique enables optimum separation of all the compounds examined and has a resolution similar to that of HPLC analysis, with the advantage of fast simultaneous measurement of cell nucleotide metabolism and redox state, not possible with HPLC.

  17. Preliminary studies of a novel multifunctional wide-bore electrophoresis system.

    Li, You-Xin; Dan, Yong-Bo; Fang, Xin; Bao, James Jianmin


    This paper presents the results obtained from a novel multifunctional analysis platform established on the basis of wide-bore electrophoresis (WBE) and CE. The WBE–CE system integrated various analytical steps including separation, transfer, reaction, detection, and storage into a single system. During the WBE–CE process, a distinct three-electrode format was adopted to continuously separate and transfer samples between WBE and CE without the interruption of switching on-and-off the power suppliers. This continuous mode of operation also helped to eliminate the need for exactly timing the transfer of specific samples zone from WBE to CE and avoided the danger of missing specific samples. Samples representing mixtures of acids, bases, or proteins were analyzed on this system for evaluating its feasibility and applicability. The results indicated that the resolution achieved on this WBE–CE system was better than either the WBE or the CE alone. Further, samples transferred out of the WBE system could participate in online reaction, such as enzymatic reaction in the CE. Alternatively, samples from the WBE system could be transferred out and stored offline in a vial for post-transfer reaction. The results demonstrated that this WBE–CE system has the potential to be a multifunctional platform for a range of applications.

  18. Alignment of capillary electrophoresis-mass spectrometry datasets using accurate mass information.

    Nevedomskaya, Ekaterina; Derks, Rico; Deelder, André M; Mayboroda, Oleg A; Palmblad, Magnus


    Capillary electrophoresis-mass spectrometry (CE-MS) is a powerful technique for the analysis of small soluble compounds in biological fluids. A major drawback of CE is the poor migration time reproducibility, which makes it difficult to combine data from different experiments and correctly assign compounds. A number of alignment algorithms have been developed but not all of them can cope with large and irregular time shifts between CE-MS runs. Here we present a genetic algorithm designed for alignment of CE-MS data using accurate mass information. The utility of the algorithm was demonstrated on real data, and the results were compared with one of the existing packages. The new algorithm showed a significant reduction of elution time variation in the aligned datasets. The importance of mass accuracy for the performance of the algorithm was also demonstrated by comparing alignments of datasets from a standard time-of-flight (TOF) instrument with those from the new ultrahigh resolution TOF maXis (Bruker Daltonics).

  19. The next generation of capillary electrophoresis instruments: performance of CE-SDS protein analysis.

    Kahle, Julia; Maul, Kai Jorrit; Wätzig, Hermann


    Over the last decade, capillary electrophoresis gained tremendous importance, because it became an indispensible tool for the quality control of biologics, e.g. therapeutic antibodies. Consequently, there has been a continuous development within the CE market. Microchip techniques have been established in the last years. Further trends are complete solutions for specific applications by the usage of reagent kits. Step by step instructions and facilitated handling of the instruments are becoming more common. This work focuses on the sized-based protein analysis with CE-SDS. The instruments CE 7100 by Agilent Technologies, LabChip® GXII Touch HT by PerkinElmer, Maurice S. by ProteinSimple and PrinCE NextI870 by Prince Technologies have been evaluated, mainly analyzing protein mixtures of different molecular weights in long series. Published data of the PA 800 plus by SCIEX are also included in the tabled results. Precision, reliability, flexibility and speed have been identified as the most important performance parameters, others such as resolution, sensitivity, linearity, ease of use and sustainability have also been considered. All tested instruments have shown an excellent performance. Depending on application and necessities, each user can find the most appropriate one. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Poly(ethylene glycol)-functionalized polymeric microchips for capillary electrophoresis.

    Sun, Xuefei; Li, Dan; Lee, Milton L


    Recently, we reported the synthesis, fabrication, and preliminary evaluation of poly(ethylene glycol) (PEG)-functionalized polymeric microchips that are inherently resistant to protein adsorption without surface modification in capillary electrophoresis (CE). In this study, we investigated the impact of cross-linker purity and addition of methyl methacrylate (MMA) as a comonomer on CE performance. Impure poly(ethylene glycol) diacrylate (PEGDA) induced electroosmotic flow (EOF) and increased the separation time, while the addition of MMA decreased the separation efficiency to approximately 25% of that obtained using microchips fabricated without MMA. Resultant improved microchips were evaluated for the separation of fluorescent dyes, amino acids, peptides, and proteins. A CE efficiency of 4.2 x 10(4) plates for aspartic acid in a 3.5 cm long microchannel was obtained. Chiral separation of 10 different D,L-amino acid pairs was obtained with addition of a chiral selector (i.e., beta-cyclodextrin) in the running buffer. Selectivity (alpha) and resolution (R(s)) for D,L-leucine were 1.16 and 1.64, respectively. Good reproducibility was an added advantage of these PEG-functionalized microchips.

  1. Principles, Practice, and Evolution of Capillary Electrophoresis as a Tool for Forensic DNA Analysis.

    Shewale, J G; Qi, L; Calandro, L M


    Capillary electrophoresis (CE) is a versatile and widely used analysis platform with application in diverse areas such as analytical chemistry, chiral separations, clinical, forensics, molecular biology, natural products, organic chemistry, and the pharmaceutical industry. Forensic applications of CE include fragment analysis, DNA sequencing, SNP typing, and analysis of gunshot residues, explosive residues, and drugs. Fragment analysis is a widely used method for short tandem repeat (STR) profiling for human identification (HID) due to the single-base resolution capability of CE. This approach circumvents the tedious and expensive approach of DNA sequencing for STR typing. The high sizing precision, ability to detect fluorescence emitted from multiple dyes, automated electrophoretic runs, and data collection software are key factors in the worldwide adoption of CE as the preferred platform for forensic DNA analysis. The most common CE systems used in forensic DNA analysis include the ABI PRISM® 310, 3100, 3100 Avant, 3130, 3130xl, 3500, and 3500xL Genetic Analyzers (GAs). The 3500 series GAs are developed with features useful for forensic scientists, including a normalization feature for analysis of the data designed to reduce the variation in peak height from instrument to instrument and injection to injection. Other hardware and software features include improved temperature control, radio frequency identification (RFID) tags for monitoring instrument consumables, HID-focused software features, and security and maintenance.

  2. Rapid level-3 characterization of therapeutic antibodies by capillary electrophoresis electrospray ionization mass spectrometry.

    Lew, Clarence; Gallegos-Perez, Jose-Luis; Fonslow, Bryan; Lies, Mark; Guttman, Andras


    With the increase of the number of approved protein therapeutics in the market, comprehensive and reproducible characterization of these new generation drugs is crucial for the biopharmaceutical industry and regulatory agencies. One of the largest groups of biotherapeutics is monoclonal antibodies (mABs) possessing various posttranslational modifications and potential degradation hotspots during the manufacturing process that may affect efficacy and immunogenicity. The exceptionally high separation power of capillary electrophoresis (CE) in conjunction with mass spectrometry fulfills Level-3 characterization requirements necessary to reveal such modifications and degradations. In this paper, a comprehensive characterization example will be given for a representative mAB Trastuzumab (Herceptin), illustrating the benefits of the integration of CE and electrospray ionization in a unified bioanalytical process coupled with high-resolution mass spectrometry. Peptides separated in a wide size range (3-65 amino acids) were identified with 100% sequence coverage and quantified, including degradative hotspots such as glutamic acid cyclization, methionine oxidation, aspargine deamidation and C-terminal lysine heterogeneity using only 100 fmol of a single protease digest sample. The low flow rate of the system (>20 nL/min) ensured maximized ionization efficiency and dramatically reduced ion suppression. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email:

  3. Capillary electrophoresis methods for the determination of covalent polyphenol-protein complexes.

    Trombley, John D; Loegel, Thomas N; Danielson, Neil D; Hagerman, Ann E


    The bioactivities and bioavailability of plant polyphenols including proanthocyanidins and other catechin derivatives may be affected by covalent reaction between polyphenol and proteins. Both processing conditions and gastrointestinal conditions may promote formation of covalent complexes for polyphenol-rich foods and beverages such as wine. Little is known about covalent reactions between proteins and tannin, because suitable methods for quantitating covalent complexes have not been developed. We established capillary electrophoresis methods that can be used to distinguish free protein from covalently bound protein-polyphenol complexes and to monitor polyphenol oxidation products. The methods are developed using the model protein bovine serum albumin and the representative polyphenol (-)epigallocatechin gallate. By pairing capillaries with different diameters with appropriate alkaline borate buffers, we are able to optimize resolution of either the protein-polyphenol complexes or the polyphenol oxidation products. This analytical method, coupled with purification of the covalent complexes by diethylaminoethyl cellulose chromatography, should facilitate characterization of covalent complexes in polyphenol-rich foods and beverages such as wine.

  4. Immunoreactivity and two-dimensional gel-electrophoresis characterization of Egyptian cobra venom proteome.

    Almehdar, Hussein Abduelrahman; Adel-Sadek, Mahmoud Abass; Redwan, Elrashdy Moustafa


    The first and second (two) dimensional gel electrophoresis has a broad protein resolution power. It was used to separate and identify cobra venom proteome. The importance of characterizing venom proteins contents from the Egyptian elapidae, specifically neurotoxins, is based on the need to produce effective anti-venom. About 30-55distinct protein spots were identified on silver stained two-dimensional gels. Around two-thirds of the venom proteins displayed low a molecular weight and a migration into hydrophobic side. The venoms from Naja haja and Naja nigricollus showed 45-55 spots, while Walternnesia aegyptia had less (31-37) spots. The commercial prepared polyclonal antivenom had a strong signal for anionic and cationic venom protein spots with molecular weight 20-115 kDa. However, it showed weak or non immunoreactivity toward anionic low molecular weight spots (2.5-15 kDa). These results suggest the need to change the immunization schedule to include low molecular weight toxin-proteomes as separate dose or sequester injection.

  5. Separation of basic proteins from Leishmania using a combination of Free flow electrophoresis (FFE) and 2D electrophoresis (2-DE) under basic conditions.

    Brotherton, Marie-Christine; Racine, Gina; Ouellette, Marc


    Basic proteins, an important class of proteins in intracellular organisms such as Leishmania, are usually underrepresented on 2D gels. This chapter describes a method combining basic proteins fractionation using Free flow electrophoresis in isoelectric focusing mode (IEF-FFE) followed by protein separation using two-dimensional gel electrophoresis (2-DE) in basic conditions. The combination of these two techniques represents a great improvement for the visualization of Leishmania proteins with basic pI using 2D gels.

  6. Migration behavior of alkylphenols, bisphenol A and bisphenol S studied by capillary electrophoresis using sulfated beta-cyclodextrin.

    Mori, M; Naraoka, H; Tsue, H; Morozumi, T; Kaneta, T; Tanaka, S


    An application of capillary electrophoresis (CE) using sulfated beta-cyclodextrin (SCD) has been investigated for separating alkylphenols with different chain lengths, as well as bisphenol A and bisphenol S. In the absence of SCD in running buffer, all the phenols migrated at the same velocity as the electroosmotic flow (EOF), whereas the addition of SCD effectively led to the baseline separation of alkylphenols on the basis of the difference in the abilities to bind into the hydrophobic cavity of CD. The host-guest binding constants between analyte phenols and SCD were evaluated from Benesi-Hildebrand plots of the data obtained by two independent methods, CE and UV-visible measurements, demonstrating that the greater the hydrophobicity of the phenols, the larger the binding constants. The effects of organic solvents on the resolution for alkylphenols and bisphenols were also examined. This system using SCD was effective for the separation of 4-octylphenol and 4-nonylphenol isomers having longer alkyl chains.

  7. Evaluation of Protein Extraction Methods for Vitis vinifera Leaf and Root Proteome Analysis by Two-Dimensional Electrophoresis

    Neila Jellouli; Asma Ben Salem; Abdelwahed Ghorbel; Hatem Ben Jouira


    An efficient protein extraction method is crucial to ensure successful separation by two-dimensional electrophoresis(2-DE)for recalcitrant plant species, in particular for grapevine(Vitis vinifera L.). Trichloroacetic acid-acetone(TCA-acetone)and phenol extraction methods were evaluated for proteome analysis of leaves and roots from the Tunisian cultivar 'Razegui'. The phenol-based protocol proved to give a higher protein yield,a greater spot resolution, and a minimal streaking on 2-DE gels for both leaf and root tissues compared with the TCA-based protocol. Furthermore, the highest numbers of detected proteins on 2-DE gels were observed using the phenol extraction from leaves and roots as compared with TCA-acetone extraction.

  8. αS1-casein in goat milk: identification of genetic variants by Capillary Zone Electrophoresis compared to Isoelectric Focusing

    G. Enne


    Full Text Available AlphaS1 casein fraction in caprine milk is characterized by an important polymorphism due to substitution, deletion of amino acids and post trascriptional modifications (Grosclaude et al., 1994; Ferranti et al., 1997. This structural polymorphism is associated to a quantitative variability in protein expression related to different milk quality and dairy properties (Pierre et al., 1998; Remeuf, 1993; Vassal et al., 1994. Classical electrophoretic methods were applied to characterize the phenotypic variants at αS1-casein fraction (Addeo et al., 1988; Russo et al., 1986. During the last ten years capillary electrophoresis became an analytical technique for rapid and automated analysis requiring small sample volume and small solvent waste. These characteristics, together with the high resolution and the chance to give quantitative results, made this technique a useful tool........

  9. Analysis of Two-Dimensional Electrophoresis Gel Images

    Pedersen, Lars


    This thesis describes and proposes solutions to some of the currently most important problems in pattern recognition and image analysis of two-dimensional gel electrophoresis (2DGE) images. 2DGE is the leading technique to separate individual proteins in biological samples with many biological...... the methods developed in the literature specifically for matching protein spot patterns, the focus is on a method based on neighbourhood relations. These methods are applied to a range of 2DGE protein spot data in a comparative study. The point pattern matching requires segmentation of the gel images...... and since the correct image segmentation can be difficult, a new alternative approach, exploiting prior knowledge from a reference gel about the protein locations to segment an incoming gel image, is proposed....

  10. Recent developments in electrochemical detection for microchip capillary electrophoresis.

    Vandaveer, Walter R; Pasas-Farmer, Stephanie A; Fischer, David J; Frankenfeld, Celeste N; Lunte, Susan M


    Significant progress in the development of miniaturized microfluidic systems has occurred since their inception over a decade ago. This is primarily due to the numerous advantages of microchip analysis, including the ability to analyze minute samples, speed of analysis, reduced cost and waste, and portability. This review focuses on recent developments in integrating electrochemical (EC) detection with microchip capillary electrophoresis (CE). These detection modes include amperometry, conductimetry, and potentiometry. EC detection is ideal for use with microchip CE systems because it can be easily miniaturized with no diminution in analytical performance. Advances in microchip format, electrode material and design, decoupling of the detector from the separation field, and integration of sample preparation, separation, and detection on-chip are discussed. Microchip CEEC applications for enzyme/immunoassays, clinical and environmental assays, as well as the detection of neurotransmitters are also described.

  11. Nanomaterial surface chemistry design for advancements in capillary electrophoresis modes.

    Ivanov, Michael R; Haes, Amanda J


    Tailored surface chemistry impacts nanomaterial function and stability in applications including in various capillary electrophoresis (CE) modes. Although colloidal nanoparticles were first integrated as colouring agents in artwork and pottery over 2000 years ago, recent developments in nanoparticle synthesis and surface modification increased their usefulness and incorporation in separation science. For instance, precise control of surface chemistry is critically important in modulating nanoparticle functionality and stability in dynamic environments. Herein, recent developments in nanomaterial pseudostationary and stationary phases will be summarized. First, nanomaterial core and surface chemistry compositions will be classified. Next, characterization methods will be described and related to nanomaterial function in various CE modes. Third, methods and implications of nanomaterial incorporation into CE will be discussed. Finally, nanoparticle-specific mechanisms likely involved in CE will be related to nanomaterial surface chemistry. Better understanding of surface chemistry will improve nanoparticle design for the integration into separation techniques.

  12. [Determination of glutamic acid in biological material by capillary electrophoresis].

    Narezhnaya, E; Krukier, I; Avrutskaya, V; Degtyareva, A; Igumnova, E A


    The conditions for the identification and determination of Glutamic acid by capillary zone electrophoresis without their preliminary derivatization have been optimized. The effect of concentration of buffer electrolyte and pH on determination of Glutamic acid has been investigated. It is shown that the 5 Mm borate buffer concentration and a pH 9.15 are optimal. Quantitative determination of glutamic acid has been carried out using a linear dependence between the concentration of the analyte and the area of the peak. The accuracy and reproducibility of the determination are confirmed by the method "introduced - found". Glutamic acid has been determined in the placenta homogenate. The duration of analysis doesn't exceed 30 minutes. The results showed a decrease in the level of glutamic acid in cases of pregnancy complicated by placental insufficiency compared with the physiological, and this fact allows to consider the level of glutamic acid as a possible marker of complicated pregnancy.

  13. Properties of nucleic acid staining dyes used in gel electrophoresis.

    Haines, Alicia M; Tobe, Shanan S; Kobus, Hilton J; Linacre, Adrian


    Nucleic acid staining dyes are used for detecting nucleic acids in electrophoresis gels. Historically, the most common dye used for gel staining is ethidium bromide, however due to its toxicity and mutagenicity other dyes that are safer to the user and the environment are preferred. This Short Communication details the properties of dyes now available and their sensitivity for detection of DNA and their ability to permeate the cell membrane. It was found that GelRed™ was the most sensitive and safest dye to use with UV light excitation, and both GelGreen™ and Diamond™ Nucleic Acid Dye were sensitive and the safer dyes using blue light excitation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Separation of enantiomers by capillary electrophoresis using pentosan polysulfate.

    Wang, X; Lee, J T; Armstrong, D W


    Pentosan polysulfate, a semisynthetic polysaccharide, was employed as a chiral run buffer additive in capillary electrophoresis. Twenty-eight racemic analytes were resolved. The separations were successful only at low pH when the analytes were significantly protonated. This suggests that ionic interactions were the dominant associative interactions between the anionic pentosan polysulfate and the positively charged analytes. Compared to other linear, carbohydrate-based chiral selectors (i.e., chondroitin sulfates, heparin and dextran sulfate) pentosan polysulfate has some characteristics common of anionic polysaccharides; yet it has several differences in its structure and properties which account for its unusual enantioselectivity. The effects of pH, concentration of phosphate buffer, concentration of pentosan polysulfate and the type and concentration of organic modifier on the enantiomeric separations were investigated. The optimization of these separations were dependent on the nature of the analytes and could be achieved by the proper choice of experimental conditions.

  15. Electrophoresis of semiflexible heteropolymers and the ``hydrodynamic Kuhn length''

    Chubynsky, Mykyta V.; Slater, Gary W.

    Semiflexible polymers, such as DNA, are rodlike for short lengths and coil-like for long lengths. For purely geometric properties, such as the end-to-end distance, the crossover between these two behaviors occurs when the polymer length is on the order of the Kuhn length. On the other hand, for the hydrodynamic friction coefficient it is easy to see by comparing the expressions for a rod and a coil that the crossover should occur at the polymer length, termed by us the hydrodynamic Kuhn length, which is larger than the ordinary Kuhn length by a logarithmic factor that can be quite significant. We show that for the problem of electrophoresis of a heteropolymer consisting of several blocks of (in general) different stiffnesses, both of these length scales can be important depending on the details of the problem.

  16. Separation of ions in acidic solution by capillary electrophoresis

    Thornton, M.


    Capillary electrophoresis (CE) is an effective method for separating ionic species according to differences in their electrophoretic mobilities. CE separations of amino acids by direct detection are difficult due to their similar electrophoretic mobilities and low absorbances. However, native amino acids can be separated by CE as cations at a low pH by adding an alkanesulfonic acid to the electrolyte carrier which imparts selectivity to the system. Derivatization is unnecessary when direct UV detection is used at 185 nm. Simultaneous speciation of metal cations such as vanadium (IV) and vanadium (V) can easily be performed without complexation prior to analysis. An indirect UV detection scheme for acidic conditions was also developed using guanidine as the background carrier electrolyte (BCE) for the indirect detection of metal cations. Three chapters have been removed for separate processing. This report contains introductory material, references, and general conclusions. 80 refs.

  17. The new approach of standardization of capillary electrophoresis

    LI; Hua; WANG; Kang; JOSEF; Havel


    In this paper, we develope the new standardization methods to eliminate the influence in capillary electrophoresis (CE). The markers were used to determine the basis position and then correct the data of sample by the migration time of standard sample, and make the migration time of samples consistent with the standard sample by the criterion of the marker. The problem of time transition was corrected in this way. Then according to the peak height or peak area of the marker in the sample (peak height was used here) compared with the standard sample, the sample data was zoomed appropriately. The absorbance error was made to be correct.The wavelet de-noise method was also used to make the data smooth and get a good baseline.

  18. Electrode substrate innovation for electrochemical detection in microchip electrophoresis.

    Randviir, Edward P; Banks, Craig E


    Microchip electrophoresis (MCE) represents the next generation of miniaturised electrophoretic devices and carry benefits such as significant improvement in analysis times, lower consumption of reagents and samples, flexibility and procedural simplicity. The devices provide a separation method for complex sample matrices and an on-board detection method for the analytical determination of a target compound. The detection part of MCE is increasingly leaning towards electrochemical methods, thus the selectivity and sensitivity of detection in MCE is dependent upon the chosen working electrode composition in addition to operating conditions of the chip such as separation voltage. Given the current plethora of electrode materials that are available, there exists a possibility to creatively integrate electrodes into MCE. This review will overview the application of several electrode materials, from the old through to the new. A particular recent focus has been the selectivity element of MCEs overcome with the use of enzymes, carbon composites and screen-printed technologies.

  19. Electrophoresis of small particles and fluid globules in weak electrolytes

    Baygents, J. C.; Saville, D. A.


    An examination is conducted of the influence of partial ionization on the electrophoresis of small particles and fluid globules, with a view to the nature of conditions under which dissociation-association (D-A) alters electrokinetics. It is found that, since D-A processes are important in cases where double-layer polarization and relaxation would otherwise prevail, the predicted effect on electrophoretic mobility is greatest for the drops and bubbles whose surfaces are fluid and convection within the interface is significant. While the computation scheme used applies only to situations where forcing-field magnitude is small, the results obtained indicate that D-A processes involving ionogenic solutes may be significant in apolar liquids where electrokinetic phenomena are driven by strong forcing fields.

  20. Microchip capillary electrophoresis based electroanalysis of triazine herbicides.

    Islam, Kamrul; Chand, Rohit; Han, Dawoon; Kim, Yong-Sang


    The number of pesticides used in agriculture is increasing steadily, leading to contamination of soil and drinking water. Herein, we present a microfluidic platform to detect the extent of contamination in soil samples. A microchip capillary electrophoresis system with in-channel electrodes was fabricated for label-free electroanalytical detection of triazine herbicides. The sample mixture contained three representative triazines: simazine, atrazine and ametryn. The electropherogram for each individual injection of simazine, atrazine and ametryn showed peaks at 58, 66 and 72 s whereas a mixture of them showed distinct peaks at 59, 67 and 71 s respectively. The technique as such may prove to be a useful qualitative and quantitative tool for the similar environmental pollutants.

  1. Explorative data analysis of two-dimensional electrophoresis gels

    Schultz, J.; Gottlieb, D.M.; Petersen, Marianne Kjerstine


    Methods for classification of two-dimensional (2-DE) electrophoresis gels based on multivariate data analysis are demonstrated. Two-dimensional gels of ten wheat varieties are analyzed and it is demonstrated how to classify the wheat varieties in two qualities and a method for initial screening...... of gels is presented. First, an approach is demonstrated in which no prior knowledge of the separated proteins is used. Alignment of the gels followed by a simple transformation of data makes it possible to analyze the gels in an automated explorative manner by principal component analysis, to determine...... if the gels should be further analyzed. A more detailed approach is done by analyzing spot volume lists by principal components analysis and partial least square regression. The use of spot volume data offers a mean to investigate the spot pattern and link the classified protein patterns to distinct spots...

  2. Rapid analysis of colipase gene variants by multicapillary electrophoresis.

    Jaczó, Zsuzsanna; Pál, Eszter; Dénes, Réka; Somogyi, Anikó; Sasvári-Székely, Mária; Guttman, András; Rónai, Zsolt


    Despite of the fact that the Human Genome Project was completed more than a decade ago, identification of the genetic background of polygenic diseases is still challenging. Several somewhat different approaches are available to investigate inheritable factors of complex phenotypes, all require, however efficient, high-throughput techniques for SNP genotyping. In this paper, we report a robust and reliable multiplex PCR-RFLP for genotype and haplotype analysis of six SNPs (rs41270082, rs3748051, rs142027015, rs3748048, rs73404011, and rs72925892) of the colipase (CLPS) gene. A multicapillary (12 capillaries) electrophoresis unit was used for high throughput and sensitive analysis of the digestion fragments. A Microsoft Excel-based spreadsheet was designed for the flexible visualization and evaluation of the electrophoretic separations, which is readily adaptable for any kind of electrophoresis application. Haplotype analysis of the two loci localized in close proximity of each other was carried out by molecular method, extended haplotypes including all five SNPs in the 5' upstream region were calculated. The techniques were applied in a case-control association study of type 2 diabetes mellitus. Although, single marker analysis did not reveal any significant association, it was observed that the rare GGCCG haplotype of the five 5' upstream region SNPs was about three times more frequent among patients compared to healthy control population. Our results demonstrated the applicability of multicapillary CGE in large-scale, high-throughput SNP analysis, and suggested that the CLPS gene polymorphisms might be considered as genetic risk factor for type 2 diabetes mellitus.

  3. Liquid crystal-enabled electrophoresis and electro-osmosis

    Lavrentovich, Oleg D.

    This work presents a comparative review of electrokinetic effects in isotropic and anisotropic (liquid crystalline) electrolytes. A special emphasis is placed on nonlinear electrokinetics with ow velocities growing as the square of the applied electric field. This phenomenon allows one to drive steady motion of particles and uids with an alternating-current electric field. In isotropic electrolytes, spatial separation of charges that leads to nonlinear electrokinetics is achieved through the properties of the solid component (typically a metal). If the electrolyte is a liquid crystal (LC), its anisotropic properties enable separation of charges in the presence of orientational distortions and under the action of an electric field. LC anisotropy leads to electrically-driven motion of colloidal particles (liquid crystal-enabled electrophoresis, LCEP) and of the LC itself (liquid crystal-enabled electro-osmosis, LCEO). The induced charge is proportional to the applied field, director gradients, anisotropy of conductivity, and anisotropy of permittivity. The electric field acts on the space separated charges to drive the electro-osmotic ows. If the director deformations lack mirror symmetry, the LC enables electrophoresis of free particles and electro-osmotic pumping. The advantage of LCenabled electrokinetics (LCEK) is that its mechanism lifts many restrictions imposed on the properties of the solid counterpart. For example, LCEP can transport particles even if these particles are deprived of any surface charges; the particles can even be a uid immiscible with a LC or a gas bubble. In a similar fashion, LCEO can drive ows even if there are no oating electrodes. Ionic currents in LCs which have been traditionally considered an undesirable feature in displays offer a broad platform for versatile applications in electrokinetics of particles and uids, micropumping and mixing, and lab-on-a-chip analysis...

  4. Instrumental development of novel detection and separation methods for capillary electrophoresis

    Garner, T.


    After a general introduction, this thesis is divided into 3 parts: indirect fluorescence detection of sugars separated by capillary zone electrophoresis with visible laser excitation, absorption detection in capillary electrophoresis by fluorescence energy transfer, and increased selectivity for electrochromatography by dynamic ion exchange.

  5. Carbon Fiber-gold/mercury Dual-electrode Detection for Capillary Electrophoresis


    A carbon fiber-gold/mercury dual-electrode for capillary electrophoresis is constructed. Cysteine, glutathione, ascorbic acid and uric acid can be detected simultaneously and selectively at the dual-electrode, respectively. The capillary electrophoresis / dual-electrode detection system has been used to determine these compounds in human blood samples.

  6. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul


    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  7. Determination of Enantiomeric Excess of Glutamic Acids by Lab-made Capillary Array Electrophoresis

    Jun WANG; Kai Ying LIU; Li WANG; Ji Ling BAI


    Simulated enantiomeric excess of glutamic acid was determined by a lab-made sixteen-channel capillary array electrophoresis with confocal fluorescent rotary scanner. The experimental results indicated that the capillary array electrophoresis method can accurately determine the enantiomeric excess of glutamic acid and can be used for high-throughput screening system for combinatorial asymmetric catalysis.

  8. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul


    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  9. The gel electrophoresis markup language (GelML) from the Proteomics Standards Initiative.

    Gibson, Frank; Hoogland, Christine; Martinez-Bartolomé, Salvador; Medina-Aunon, J Alberto; Albar, Juan Pablo; Babnigg, Gyorgy; Wipat, Anil; Hermjakob, Henning; Almeida, Jonas S; Stanislaus, Romesh; Paton, Norman W; Jones, Andrew R


    The Human Proteome Organisation's Proteomics Standards Initiative has developed the GelML (gel electrophoresis markup language) data exchange format for representing gel electrophoresis experiments performed in proteomics investigations. The format closely follows the reporting guidelines for gel electrophoresis, which are part of the Minimum Information About a Proteomics Experiment (MIAPE) set of modules. GelML supports the capture of metadata (such as experimental protocols) and data (such as gel images) resulting from gel electrophoresis so that laboratories can be compliant with the MIAPE Gel Electrophoresis guidelines, while allowing such data sets to be exchanged or downloaded from public repositories. The format is sufficiently flexible to capture data from a broad range of experimental processes, and complements other PSI formats for MS data and the results of protein and peptide identifications to capture entire gel-based proteome workflows. GelML has resulted from the open standardisation process of PSI consisting of both public consultation and anonymous review of the specifications.

  10. Gene analysis of multiple oral bacteria by the polymerase chain reaction coupled with capillary polymer electrophoresis.

    Liu, Chenchen; Yamaguchi, Yoshinori; Sekine, Shinichi; Ni, Yi; Li, Zhenqing; Zhu, Xifang; Dou, Xiaoming


    Capillary polymer electrophoresis is identified as a promising technology for the analysis of DNA from bacteria, virus and cell samples. In this paper, we propose an innovative capillary polymer electrophoresis protocol for the quantification of polymerase chain reaction products. The internal standard method was modified and applied to capillary polymer electrophoresis. The precision of our modified internal standard protocol was evaluated by measuring the relative standard deviation of intermediate capillary polymer electrophoresis experiments. Results showed that the relative standard deviation was reduced from 12.4-15.1 to 0.6-2.3%. Linear regression tests were also implemented to validate our protocol. The modified internal standard method showed good linearity and robust properties. Finally, the ease of our method was illustrated by analyzing a real clinical oral sample using a one-run capillary polymer electrophoresis experiment.

  11. Capillary Electrophoresis for the Simultaneous Determination of Metals by Using Ethylenediamine Tetraacetic Acid as Complexing Agent and Vancomycin as Complex Selector

    THREEPROM, Jirasak; SOM-AUM, Waraporn; LIN, Jin-Ming


    A new separation system of capillary electrophoresis for the simultaneous determination of metals by using ethylenediamine tetraacetic acid (EDTA) as complexing agent and employing vancomycin as complex selector was described. The Z-shape cell capillary electrophoresis was used to enhance the sensitivity for the determination of the complexes of Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ) and Fe(Ⅲ) with EDTA. The partial filling method (co-current mode) was used in order to increase the selectivity of the electrophoretic method, meanwhile vancomycin was not present at the detector path during the detection of metal-EDTA complexes. The vancomycin concentration, phosphate concentration and pH of the buffer strongly influenced mobility, resolution and selectivity of the studied analytes. Under the optimal condition, the relative standard deviations (n=5) of the migration time and the peak area were less than 3.14% and 7.35%, respectively. Application of the Z-shape cell capillary electrophoresis method with UV detection and vancomycin loading led to the reliable determination of these metal ions in tap water and the recoveries were 97%-101%. The detection limits based on a signal to noise ratio of 3: 1 were found in the range of 2-10 μg·L-1.

  12. Electrophoretic Focusing: An Alternative to Capillary Electrophoresis Project

    National Aeronautics and Space Administration — Electrophoretic focusing is a new separation method intended to achieve high resolution within very short sample residence times because one fraction is separated at...

  13. 16S-23S Internal Transcribed Spacer Region PCR and Sequencer-Based Capillary Gel Electrophoresis has Potential as an Alternative to High Performance Liquid Chromatography for Identification of Slowly Growing Nontuberculous Mycobacteria

    Subedi, Shradha; Kong, Fanrong; Jelfs, Peter; Gray, Timothy J; Xiao, Meng; Sintchenko, Vitali; Chen, Sharon C-A.


    Accurate identification of slowly growing nontuberculous mycobacteria (SG-NTM) of clinical significance remains problematic. This study evaluated a novel method of SG-NTM identification by amplification of the mycobacterial 16S-23S rRNA internal transcribed spacer (ITS) region followed by resolution of amplified fragments by sequencer-based capillary gel electrophoresis (SCGE). Fourteen American Type Culture Collection (ATCC) strains and 103 clinical/environmental isolates (total n = 24 speci...

  14. Index Conditions of Resolution

    Xiao-Chun Cheng


    In this paper, the following results are proved: (1) Using both deletion strategy and lock strategy, resolution is complete for a clause set where literals with the same predicate or proposition symbol have the same index. (2) Using deletion strategy, both positive unit lock resolution and input lock resolution are complete for a Horn set where the indexes of positive literals are greater than those of negative literals. (3) Using deletion strategy, input half-lock resolution is complete for a Horn set.

  15. Capillary electrophoresis-chemiluminescence determination of norfloxacin and prulifloxacin

    Yang Zhongju; Wang Xiaoli [College of Chemistry, Beijing Normal University, Beijing 100875 (China); Qin Weidong [College of Chemistry, Beijing Normal University, Beijing 100875 (China)], E-mail:; Zhao Huichun [College of Chemistry, Beijing Normal University, Beijing 100875 (China)], E-mail:


    A capillary electrophoresis (CE)-chemiluminescence (CL) method for determining norfloxacin (NFLX) and prulifloxacin (PFLX) was developed based on the enhanced CL intensity of the cerium(IV)-sulfite-fluoroquinolone (FQ) reaction sensitized by terbium(III). The separation was conducted in buffer composed of 20 mM sodium citrate, 4 mM citric acid and 10 mM sodium sulfite at pH 6.1. The CL reagent solution consisted of 2 mM cerium(IV), 4 mM terbium(III) and 1.1 mM hydrochloric acid. NFLX and PFLX were baseline separated within 11 min with detection limits (S/N = 3) of 0.057 and 0.084 {mu}g mL{sup -1}, respectively. The maximum intra- and inter-day relative standard deviations (R.S.D.s) of migration time of the analytes were less than 4.0% and 4.2%, respectively. The proposed method was applied to detect NFLX and PFLX in fortified urine sample and the results were comparable to high-performance liquid chromatography (HPLC)-UV method. Moreover, the high selectivity of the CL detection and the high-separation efficiency of CE render the method the potential of quick analyzing fluoroquinolones in real complex matrix.

  16. Particle electrophoresis for quality assurance and process control.

    Seaman, G V; Knox, R J


    Process control is an increasingly important issue as life science companies world-wide strive for recognition of their manufacturing and product development quality measures according to International Standards Organization (ISO) or good manufacturing practices (GMP) standards. Analytical particle electrophoresis (APE) has the potential for significant contributions, not just to basic research, but also in process development and control in manufacturing environments. An important feature of colloidal (small) particles, which controls their behavior, is their surface charge. Optimization of life science products and process conditions involving small particles (>100 nm) may be approached by a variety of strategies based upon direct measurements of the charge properties of process particles or "reporter" particles. The availability of increasingly powerful instruments and control particle preparations (National Institute of Standards and Technology ((NIST) and others) for validation of instrument operation make the method more attractive than ever. We summarize highly flexible electrophoretic strategies for assessing process consistency both from the perspective of particles being processed as well as the processing environment and describe principles for the use of polymer microspheres both as control particles for validation of instrument operation as well as for probes of the assay medium.

  17. Determination of acidity constants of enolisable compounds by capillary electrophoresis.

    Mofaddel, N; Bar, N; Villemin, D; Desbène, P L


    Research on the structure-activity relationships of molecules with acidic carbon atoms led us to undertake a feasibility study on the determination of their acidity constants by capillary electrophoresis (CE). The studied molecules had diverse structures and were tetronic acid, acetylacetone, diethylmalonate, Meldrum's acid, 3-methylrhodanine, nitroacetic acid ethyl ester, pyrimidine-2,4,6-trione, 3-oxo-3-phenylpropionic acid ethyl ester, 1-phenylbutan-1,3-dione, 5,5-dimethylcyclohexan-1,3-dione and homophthalic anhydride. The p Ka range explored by CE was therefore very large (from 3 to 12) and p Ka values near 12 were evaluated by mathematical extrapolations. The analyses were carried out in CZE mode using a fused silica capillary grafted (or not) with hexadimethrine. Owing to the electrophoretic behaviour of these compounds according to the pH, their acidity constants could be evaluated and appeared in perfect agreement with the literature data obtained, a few decades ago, by means of potentiometry, spectrometry or conductimetry. The p Ka of homophthalic anhydride and 3-methylrhodanine were evaluated for the first time.

  18. Latex samples for RAMSES electrophoresis experiment on IML 2

    Seaman, Geoffrey V. F.; Knox, Robert J.


    The objectives of these reported studies were to provide ground based support services for the flight experiment team for the RAMSES experiment to be flown aboard IML-2. The specific areas of support included consultation on the performance of particle based electrophoresis studies, development of methods for the preparation of suitable samples for the flight hardware, the screening of particles to obtain suitable candidates for the flight experiment, and the electrophoretic characterization of sample particle preparations. The first phases of these studies were performed under this contract, while the follow on work was performed under grant number NAG8 1081, 'Preparation and Characterization of Latex Samples for RAMSES Experiment on IML 2.' During this first phase of the experiment the following benchmarks were achieved: Methods were tested for the concentration and resuspension of latex samples in the greater than 0.4 micron diameter range to provide moderately high solids content samples free of particle aggregation which interferred with the normal functioning of the RAMSES hardware. Various candidate latex preparations were screened and two candidate types of latex were identified for use in the flight experiments, carboxylate modified latex (CML) and acrylic acid-acrylamide modified latex (AAM). These latexes have relatively hydrophilic surfaces, are not prone to aggregate, and display sufficiently low electrophoretic mobilities in the flight buffer so that they can be used to make mixtures to test the resolving power of the flight hardware.

  19. Study on Dicarboxylic Acids in Aerosol Samples with Capillary Electrophoresis

    Heidi Adler


    Full Text Available The research was performed to study the simultaneous detection of a homologous series of α, ω-dicarboxylic acids (C2–C10, oxalic, malonic, succinic, glutaric, adipic, pimelic, suberic, azelaic, and sebacic acids, with capillary electrophoresis using indirect UV detection. Good separation efficiency in 2,6-pyridinedicarboxylic acid as background electrolyte modified with myristyl trimethyl ammonium bromide was obtained. The dicarboxylic acids were ionised and separated within five minutes. For the study, authentic samples were collected onto dry cellulose membrane filters of a cascade impactor (12 stages from outdoor spring aerosols in an urban area. Hot water and ultrasonication extraction methods were used to isolate the acids from membrane filters. Due to the low concentrations of acids in the aerosols, the extracts were concentrated with solid-phase extraction (SPE before determination. The enrichment of the carboxylic acids was between 86 and 134% with sample pretreatment followed by 100-time increase by preparation of the sample to 50 μL. Inaccuracy was optimised for all the sample processing steps. The aerosols contained dicarboxylic acids C2–C10. Then, mostly they contained C2, C5, and C10. Only one sample contained succinic acid. In the study, the concentrations of the acids in aerosols were lower than 10 ng/m3.

  20. Numerical modeling of capillary electrophoresis - electrospray mass spectrometry interface design.

    Jarvas, Gabor; Guttman, Andras; Foret, Frantisek


    Capillary electrophoresis hyphenated with electrospray mass spectrometry (CE-ESI-MS) has emerged in the past decade as one of the most powerful bioanalytical techniques. As the sensitivity and efficiency of new CE-ESI-MS interface designs are continuously improving, numerical modeling can play important role during their development. In this review, different aspects of computer modeling and simulation of CE-ESI-MS interfaces are comprehensively discussed. Relevant essentials of hydrodynamics as well as state-of-the-art modeling techniques are critically evaluated. Sheath liquid-, sheathless-, and liquid-junction interfaces are reviewed from the viewpoint of multidisciplinary numerical modeling along with details of single and multiphase models together with electric field mediated flows, electrohydrodynamics, and free fluid-surface methods. Practical examples are given to help non-specialists to understand the basic principles and applications. Finally, alternative approaches like air amplifiers are also included. © 2014 Wiley Periodicals, Inc. Mass Spec Rev 34: 558-569, 2015. © 2014 Wiley Periodicals, Inc.

  1. Photochemical Microscale Electrophoresis Allows Fast Quantification of Biomolecule Binding.

    Möller, Friederike M; Kieß, Michael; Braun, Dieter


    Intricate spatiotemporal patterns emerge when chemical reactions couple to physical transport. We induce electrophoretic transport by a confined photochemical reaction and use it to infer the binding strength of a second, biomolecular binding reaction under physiological conditions. To this end, we use the photoactive compound 2-nitrobenzaldehyde, which releases a proton upon 375 nm irradiation. The charged photoproducts locally perturb electroneutrality due to differential diffusion, giving rise to an electric potential Φ in the 100 μV range on the micrometer scale. Electrophoresis of biomolecules in this field is counterbalanced by back-diffusion within seconds. The biomolecule concentration is measured by fluorescence and settles proportionally to exp(-μ/D Φ). Typically, binding alters either the diffusion coefficient D or the electrophoretic mobility μ. Hence, the local biomolecule fluorescence directly reflects the binding state. A fit to the law of mass action reveals the dissociation constant of the binding reaction. We apply this approach to quantify the binding of the aptamer TBA15 to its protein target human-α-thrombin and to probe the hybridization of DNA. Dissociation constants in the nanomolar regime were determined and match both results in literature and in control experiments using microscale thermophoresis. As our approach is all-optical, isothermal and requires only nanoliter volumes at nanomolar concentrations, it will allow for the fast screening of biomolecule binding in low volume multiwell formats.

  2. Epidemiological Typing of Moraxella Catarrhalis by Pulsed Field Gel Electrophoresis

    Susan M Davison


    Full Text Available Pulsed field gel electrophoresis (pfge was used to compare 59 strains of Moraxella catarrhalis to evaluate pfge for the epidemiological typing of this organism. pfge-generated patterns were compared with those obtained by small fragment restriction enzyme analysis (rea and species-specific probe hybridization. The strains used in the study were isolated from various geographic locations and included proven epidemiologically related strains. pfge yielded more unique patterns than dna-dna hybridization – 30 versus 18, respectively – but fewer than rea, which generated 45 unique patterns. Strains that demonstrated the same rea pattern or dna-dna hybridization pattern did not always demonstrate the same pfge pattern. For example, in 23 epidemiologically unrelated strains that shared six rea patterns, pfge differentiated the isolates into 12 patterns. Conversely, strains that demonstrated the same pfge pattern did not always demonstrate the same rea pattern or hybridization pattern. For example, in 42 strains that shared 13 pfge patterns, rea differentiated the isolates into 31 patterns and dna-dna hybridization differentiated them into 16 patterns. However, compared with rea, pfge yielded less complex patterns that were more easily comparable, and compared with dna-dna hybridization, pfge was technically easier.

  3. Free-flow electrophoresis for fractionation of Arabidopsis thaliana membranes.

    Bardy, N; Carrasco, A; Galaud, J P; Pont-Lezica, R; Canut, H


    Highly purified tonoplast and plasma membrane vesicles were isolated from microsomes of Arabidopsis thaliana by preparative free-flow electrophoresis. The most electronegative fractions were identified as tonoplast using nitrate-inhibited Mg2+-ATPase as enzyme marker. The least electronegative fractions were identified as plasma membrane using glucan-synthase II, UDPG: sterol-glucosyl-transferase, and vanadate-inhibited Mg2+-ATPase as enzyme markers. Other membrane markers, latent inosine-5'-diphosphatase (Golgi), NADPH-cytochrome-c reductase (endoplasmic reticulum) and cytochrome-c oxidase (mitochondria) were recovered in the fractions intermediate between tonoplast and plasma membrane. Immunoblot analysis of membrane fractions by antibodies directed against tonoplast and plasma membrane proteins confirmed the nature and the purity of the isolated membranes. The cytoskeletal protein actin, which was also identified by immunoblotting, was found to be specifically attached to the plasma membrane vesicles. The structural and functional integrity of the isolated membranes from Arabidopsis thaliana is discussed in the light of results obtained for the location of receptors and enzymes, or for the determination of ligand binding activity.

  4. Non-Gradient Blue Native Polyacrylamide Gel Electrophoresis.

    Luo, Xiaoting; Wu, Jinzi; Jin, Zhen; Yan, Liang-Jun


    Gradient blue native polyacrylamide gel electrophoresis (BN-PAGE) is a well established and widely used technique for activity analysis of high-molecular-weight proteins, protein complexes, and protein-protein interactions. Since its inception in the early 1990s, a variety of minor modifications have been made to this gradient gel analytical method. Here we provide a major modification of the method, which we call non-gradient BN-PAGE. The procedure, similar to that of non-gradient SDS-PAGE, is simple because there is no expensive gradient maker involved. The non-gradient BN-PAGE protocols presented herein provide guidelines on the analysis of mitochondrial protein complexes, in particular, dihydrolipoamide dehydrogenase (DLDH) and those in the electron transport chain. Protocols for the analysis of blood esterases or mitochondrial esterases are also presented. The non-gradient BN-PAGE method may be tailored for analysis of specific proteins according to their molecular weight regardless of whether the target proteins are hydrophobic or hydrophilic. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  5. Simultaneous quantification of sialyloligosaccharides from human milk by capillary electrophoresis.

    Bao, Yuanwu; Zhu, Libin; Newburg, David S


    The acidic oligosaccharides of human milk are predominantly sialyloligosaccharides. Pathogens that bind sialic acid-containing glycans on their host mucosal surfaces may be inhibited by human milk sialyloligosaccharides, but testing this hypothesis requires their reliable quantification in milk. Sialyloligosaccharides have been quantified by anion exchange high-performance liquid chromatography (HPLC), reverse- or normal-phase HPLC, and capillary electrophoresis (CE) of fluorescent derivatives; in milk, these oligosaccharides have been analyzed by high pH anion exchange chromatography with pulsed amperometric detection and, in our laboratory, by CE with detection at 205nm. The novel method described here uses a running buffer of aqueous 200mM NaH2PO4 (pH 7.05) containing 100mM sodium dodecyl sulfate (SDS) mixed with 45% (v/v) methanol to baseline resolve 5 oligosaccharides and separate all 12. This allows automated simultaneous quantification of the 12 major sialyloligosaccharides of human milk in a single 35-min run. This method revealed differences in sialyloligosaccharide concentrations between less and more mature milk from the same donors. Individual donors also varied in expression of sialyloligosaccharides in their milk. Thus, the facile quantification of sialyloligosaccharides by this method is suitable for measuring variation in expression of specific sialyloligosaccharides in milk and their relationship to decreased risk of specific diseases in infants.

  6. Quantification of sugars in breakfast cereals using capillary electrophoresis.

    Toutounji, Michelle R; Van Leeuwen, Matthew P; Oliver, James D; Shrestha, Ashok K; Castignolles, Patrice; Gaborieau, Marianne


    About 80% of the Australian population consumes breakfast cereal (BC) at least five days a week. With high prevalence rates of obesity and other diet-related diseases, improved methods for monitoring sugar levels in breakfast cereals would be useful in nutrition research. The heterogeneity of the complex matrix of BCs can make carbohydrate analysis challenging or necessitate tedious sample preparation leading to potential sugar loss or starch degradation into sugars. A recently established, simple and robust free solution capillary electrophoresis (CE) method was used in a new application to 13 BCs (in Australia) and compared with several established methods for quantification of carbohydrates. Carbohydrates identified in BCs by CE included sucrose, maltose, glucose and fructose. The CE method is simple requiring no sample preparation or derivatization and carbohydrates are detected by direct UV detection. CE was shown to be a more robust and accurate method for measuring carbohydrates than Fehling method, DNS (3,5-dinitrosalicylic acid) assay and HPLC (high performance liquid chromatography).

  7. Electrochemical methods in conjunction with capillary and microchip electrophoresis.

    Mark, Jonas J P; Scholz, Rebekka; Matysik, Frank-Michael


    Electromigrative techniques such as capillary and microchip electrophoresis (CE and MCE) are inherently associated with various electrochemical phenomena. The electrolytic processes occurring in the buffer reservoirs have to be considered for a proper design of miniaturized electrophoretic systems and a suitable selection of buffer composition. In addition, the control of the electroosmotic flow plays a crucial role for the optimization of CE/MCE separations. Electroanalytical methods have significant importance in the field of detection in conjunction with CE/MCE. At present, amperometric detection and contactless conductivity detection are the predominating electrochemical detection methods for CE/MCE. This paper reviews the most recent trends in the field of electrochemical detection coupled to CE/MCE. The emphasis is on methodical developments and new applications that have been published over the past five years. A rather new way for the implementation of electrochemical methods into CE systems is the concept of electrochemically assisted injection which involves the electrochemical conversions of analytes during the injection step. This approach is particularly attractive in hyphenation to mass spectrometry (MS) as it widens the range of CE-MS applications. An overview of recent developments of electrochemically assisted injection coupled to CE is presented.

  8. Analytical characterization of wine and its precursors by capillary electrophoresis.

    Gomez, Federico J V; Monasterio, Romina P; Vargas, Verónica Carolina Soto; Silva, María F


    The accurate determination of marker chemical species in grape, musts, and wines presents a unique analytical challenge with high impact on diverse areas of knowledge such as health, plant physiology, and economy. Capillary electromigration techniques have emerged as a powerful tool, allowing the separation and identification of highly polar compounds that cannot be easily separated by traditional HPLC methods, providing complementary information and permitting the simultaneous analysis of analytes with different nature in a single run. The main advantage of CE over traditional methods for wine analysis is that in most cases samples require no treatment other than filtration. The purpose of this article is to present a revision on capillary electromigration methods applied to the analysis of wine and its precursors over the last decade. The current state of the art of the topic is evaluated, with special emphasis on the natural compounds that have allowed wine to be considered as a functional food. The most representative revised compounds are phenolic compounds, amino acids, proteins, elemental species, mycotoxins, and organic acids. Finally, a discussion on future trends of the role of capillary electrophoresis in the field of analytical characterization of wines for routine analysis, wine classification, as well as multidisciplinary aspects of the so-called "from soil to glass" chain is presented.

  9. A versatile electrophoresis-based self-test platform.

    Staal, Steven; Ungerer, Mathijn; Floris, Arjan; Ten Brinke, Hans-Willem; Helmhout, Roy; Tellegen, Marian; Janssen, Kjeld; Karstens, Erik; van Arragon, Charlotte; Lenk, Stefan; Staijen, Erik; Bartholomew, Jody; Krabbe, Hans; Movig, Kris; Dubský, Pavel; van den Berg, Albert; Eijkel, Jan


    This paper reports on recent research creating a family of electrophoresis-based point of care devices for the determination of a wide range of ionic analytes in various sample matrices. These devices are based on a first version for the point-of-care measurement of Li(+), reported in 2010 by Floris et al. (Lab Chip 2010, 10, 1799-1806). With respect to this device, significant improvements in accuracy, precision, detection limit, and reliability have been obtained especially by the use of multiple injections of one sample on a single chip and integrated data analysis. Internal and external validation by clinical laboratories for the determination of analytes in real patients by a self-test is reported. For Li(+) in blood better precision than the standard clinical determination for Li(+) was achieved. For Na(+) in human urine the method was found to be within the clinical acceptability limits. In a veterinary application, Ca(2+) and Mg(2+) were determined in bovine blood by means of the same chip, but using a different platform. Finally, promising preliminary results are reported with the Medimate platform for the determination of creatinine in whole blood and quantification of both cations and anions through replicate measurements on the same sample with the same chip.

  10. Mecanismos de Separação em Eletroforese Capilar Separation Mechanisms in Capillary Electrophoresis

    Marina F. M. Tavares


    Full Text Available Since its inception in the 80's, capillary electrophoresis has matured into a well established technique for the separation and analysis of complex samples. One of its strongest aspects is the ability to handle materials from a diversity of chemical classes, ranging from few to millions of Daltons. This is only possible because several modes of electrophoresis can be performed in a single capillary format. In this work, relevant aspects of capillary zone electrophoresis in its three modes (free solution, micellar and gel, capillary isoelectric focusing and capillary isotachophoresis are discussed and many representative applications are presented.

  11. Preparation of Barley Storage Protein, Hordein, for Analytical Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis

    Doll, Hans; Andersen, Bente


    The extraction, reduction, and alkylation of barley hordein for routine electrophoresis in sodium dodecyl sulfate-polyacrylamide gels were studied to set up a simple preparation procedure giving well-resolved bands in the electrophoresis gel. Hordein was extracted from single crushed seeds or flour...... by aqueous 50% propan-2-ol containing a Tris-borate buffer, pH 8.6. The presence of the buffer facilitates the consecutive complete reduction of the extracted protein in the alcohol. Reduction and alkylation in the buffer containing propan-2-ol give sharper bands in the electrophoresis than reduction...

  12. Occurrence of Double Monoclonal Bands on Protein Electrophoresis: An Unusual Finding.

    Srinivasan, Vishrut K; Bhagat, Priyanka; Bansal, Frainey; Chhabra, Seema


    Various techniques of protein electrophoresis are used for detection of monoclonal proteins/paraproteins in serum and/or urine of patients with monoclonal gammopathies. These are detected as the so-called 'M' bands (monoclonal bands) on serum protein electrophoresis and/or immunofixation electrophoresis. In most cases, a single M-band is detected. However, more than one M-band can be detected in the samples of a minor proportion of patients. This condition is termed as 'double gammopathy' or 'biclonal gammopathy'. A knowledge of such an unusual occurrence is essential for recognition and appropriate interpretation of this entity.

  13. Continuous fractionation of a two-component mixture by zone electrophoresis.

    Zalewski, Dawid R; Gardeniers, Han J G E


    Synchronized continuous-flow zone electrophoresis is a recently demonstrated tool for performing electrophoretic fractionation of a complex sample. The method resembles free flow electrophoresis, but unlike in that technique, no mechanical fluid pumping is required. Instead, fast electrokinetic flow switching is used to produce complex stream patterns, which results in lateral separation of components in a separation chamber. Here a solution is presented which allows for simultaneous collection of two fractions in synchronized continuous-flow zone electrophoresis. The method is demonstrated on a model mixture, with subsequent evaluation of the collected fractions purity by MCE. The necessary theoretical background is provided including both steering schemes and calculations of optimum operating points.

  14. Effect of temperature on electrophoresis velocity of sol particles in water

    鲍治宇; 顾大明


    Viscosity of water is affected by temperature and electrophoresis velocity is related to the viscosity of colloid. However, there hasn' t been any direct description about the relation between electrophoresis velocity of colloid and temperature. Based on a large number of tests, the relation between electrophoresis velocity and temperature is established as [ v = A + B( T-T°) ]. Meanwhile the ratio of the electric charge (q) of sol particles to their radium (r) is a constant is obtained. The results of above were testified in both experiment and theory.

  15. Advances in Automation and Throughput of the Mars Organic Analyzer Microchip Capillary Electrophoresis System

    Haldeman, B. J.; Skelley, A. M.; Scherer, J. R.; Jayarajah, C.; Mathies, R. A.


    We have previously demonstrated the design, construction and testing of a portable microchip capillary electrophoresis (CE) instrument called the Mars Organic Analyzer (MOA) for analysis of amino acids and amine containing organic molecules (1). This instrument is designed to accept organic compounds isolated from samples by sublimation or by subcritical water extraction, to label the amine groups with fluorescamine, and to perform high resolution electrophoretic analysis. The CE instrument has shown remarkable robustness during successful field tests last year in the Panoche Valley, CA (1) and more recently in the Atacama Desert, Chile (2). For successful operation on Mars, however, it is necessary to operate autonomously and to analyze large numbers of samples, blanks, and standards. Toward this end we present here two advances in the MOA system that test key aspects of an eventual flight prototype. First, we have developed an automated microfluidic system and method for the autonomous loading, running and cleaning of the CE chip on the single channel MOA instrument. The integration of microfabricated PDMS valves and pumps with all-glass separation channels in a multilayer design enabled creation of structures for complex fluidic routing. Twenty sequential analyses of an amino acid standard were performed with an automated cleaning procedure between runs. In addition, dilutions were performed on-chip, and blanks were run to demonstrate the elimination of carry-over from run to run. These results demonstrate an important advance of the technology readiness level of the MOA. Second, we have designed, constructed and successfully tested a lab version of the multichannel instrument we initially proposed for the MSL opportunity. The portable Multi-Channel Mars Organic Analyzer (McMOA, 25 by 30 by 15 cm), was designed to sequentially interrogate eight radially oriented CE separation channels on a single wafer. Since each channel can be used to analyze 20 or more

  16. Equivariant cohomology and resolution

    Albin, Pierre


    The `Folk Theorem' that a smooth action by a compact Lie group can be (canonically) resolved, by iterated blow up, to have unique isotropy type is proved in the context of manifolds with corners. This procedure is shown to capture the simultaneous resolution of all isotropy types in a `resolution tower' which projects to a resolution, with iterated boundary fibration, of the quotient. Equivariant K-theory and the Cartan model for equivariant cohomology are tracked under the resolution procedure as is the delocalized equivariant cohomology of Baum, Brylinski and MacPherson. This leads to resolved models for each of these cohomology theories, in terms of relative objects over the resolution tower and hence to reduced models as flat-twisted relative objects over the resolution of the quotient. As a result an explicit equivariant Chern character is constructed, essentially as in the non-equivariant case, over the resolution of the quotient.

  17. Effect of temperature gradients on single-strand conformation polymorphism analysis in a capillary electrophoresis system using Pluronic polymer matrix.

    Hwang, Hee Sung; Shin, Gi Won; Park, Han Jin; Ryu, Chang Y; Jung, Gyoo Yeol


    Capillary electrophoresis-single strand conformation polymorphism (CE-SSCP) analysis is a prominent bioseparation method based on the mobility diversity caused by sequence-induced conformational differences of single-stranded DNA. The use of Pluronic polymer matrix has opened up new opportunities for CE-SSCP, because it improved the resolution for various genetic analyses. However, there still exists a challenge in optimizing Pluronic-based CE-SSCP, because the physical properties of Pluronic solutions are sensitive to temperature, particularly near the gelation temperature, where the viscoelasticity of Pluronic F108 solutions sharply changes from that of a Newtonian fluid to a hydrogel upon heating. We have focused on a set of experiments to control the ambient temperature of the CE system with the aim of enhancing the reliability of the CE-SSCP analysis by using the Applied Biosystems ABI 3130xl genetic analyzer with Pluronic F108 solution matrix. The ambient temperature control allowed us to vary the inlet and outlet portion of the capillary column, while the temperature of the column was kept at 35°C. The resolution to separate 2 single-base-pair-differing DNA fragments was significantly enhanced by changing the temperature from 19 to 30°C. The viscoelastic properties of the F108 solution matrix upon heating were also investigated by ex situ rheological experiments with an effort to reveal how the development of gels in Pluronic solutions affects the resolution of CE-SSCP. We found that the column inlet and outlet temperatures of the capillary column have to be controlled to optimize the resolution in CE-SSCP by using the Pluronic matrix.

  18. High-Throughput Genetic Analysis and Combinatorial Chiral Separations Based on Capillary Electrophoresis

    Wenwan Zhong


    Capillary electrophoresis (CE) offers many advantages over conventional analytical methods, such as speed, simplicity, high resolution, low cost, and small sample consumption, especially for the separation of enantiomers. However, chiral method developments still can be time consuming and tedious. They designed a comprehensive enantioseparation protocol employing neutral and sulfated cyclodextrins as chiral selectors for common basic, neutral, and acidic compounds with a 96-capillary array system. By using only four judiciously chosen separation buffers, successful enantioseparations were achieved for 49 out of 54 test compounds spanning a large variety of pKs and structures. Therefore, unknown compounds can be screened in this manner to identify optimal enantioselective conditions in just one rn. In addition to superior separation efficiency for small molecules, CE is also the most powerful technique for DNA separations. Using the same multiplexed capillary system with UV absorption detection, the sequence of a short DNA template can be acquired without any dye-labels. Two internal standards were utilized to adjust the migration time variations among capillaries, so that the four electropherograms for the A, T, C, G Sanger reactions can be aligned and base calling can be completed with a high level of confidence. the CE separation of DNA can be applied to study differential gene expression as well. Combined with pattern recognition techniques, small variations among electropherograms obtained by the separation of cDNA fragments produced from the total RNA samples of different human tissues can be revealed. These variations reflect the differences in total RNA expression among tissues. Thus, this Ce-based approach can serve as an alternative to the DNA array techniques in gene expression analysis.

  19. Capillary zone electrophoresis for enumeration of Lactobacillus delbrueckii subsp. bulgaricus and Streptococcus thermophilus in yogurt.

    Lim, Orathai; Suntornsuk, Worapot; Suntornsuk, Leena


    Enumeration of Lactobacillus delbrueckii subsp. bulgaricus and Streptococcus thermophilus is a priority due to their importance in yogurt production. Capillary electrophoresis (CE) of both bacteria could be achieved in 7.2 min with a resolution of 3.2 in the background electrolyte (BGE) containing 4.5mM Tris(hydroxymethyl) amminomethane (TRIS)-4.5 mM boric acid-0.1 mM ethylenediamine tetraacetate (EDTA) (TBE) buffer (pH 8.4) and 0.05% (v/v) polyethylene oxide (PEO), using a capillary of 47.5 cm (effective length) x 100 microm i.d., injection of 50 mbar x 3s followed by -5kV x 120s, a voltage and temperature of 20 kV and 25 degrees C, respectively. Appropriate amounts of PEO in the BGE, sample preparation (i.e. vortex) and introduction were key factors for their separation. A short hydrodynamic injection followed by applying reversed polarity voltage could compress the bacteria into narrow zones, which were detected as separated single peaks. Method linearity (r(2)>0.99), precision (%RSDsyogurt were not statistically different from those of the plate count method (P>0.05). The CE method can be used as an alternative for quantitation of L. delbrueckii subsp. bulgaricus and S. thermophilus in yogurt since it was reliable, simple, cost and labor effective and rapid, allowing the analysis of 3 samples/h (comparing to 2d/sample by plate count method).

  20. Identification of inorganic improvised explosive devices using sequential injection capillary electrophoresis and contactless conductivity detection.

    Blanco, Gustavo A; Nai, Yi H; Hilder, Emily F; Shellie, Robert A; Dicinoski, Greg W; Haddad, Paul R; Breadmore, Michael C


    A simple sequential injection capillary electrophoresis (SI-CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) has been developed for the rapid separation of anions relevant to the identification of inorganic improvised explosive devices (IEDs). Four of the most common explosive tracer ions, nitrate, perchlorate, chlorate, and azide, and the most common background ions, chloride, sulfate, thiocyanate, fluoride, phosphate, and carbonate, were chosen for investigation. Using a separation electrolyte comprising 50 mM tris(hydroxymethyl)aminomethane, 50 mM cyclohexyl-2-aminoethanesulfonic acid, pH 8.9 and 0.05% poly(ethyleneimine) (PEI) in a hexadimethrine bromide (HDMB)-coated capillary it was possible to partially separate all 10 ions within 90 s. The combination of two cationic polymer additives (PEI and HDMB) was necessary to achieve adequate selectivity with a sufficiently stable electroosmotic flow (EOF), which was not possible with only one polymer. Careful optimization of variables affecting the speed of separation and injection timing allowed a further reduction of separation time to 55 s while maintaining adequate efficiency and resolution. Software control makes high sample throughput possible (60 samples/h), with very high repeatability of migration times [0.63-2.07% relative standard deviation (RSD) for 240 injections]. The separation speed does not compromise sensitivity, with limits of detection ranging from 23 to 50 μg·L(-1) for all the explosive residues considered, which is 10× lower than those achieved by indirect absorbance detection and 2× lower than those achieved by C(4)D using portable benchtop instrumentation. The combination of automation, high sample throughput, high confidence of peak identification, and low limits of detection makes this methodology ideal for the rapid identification of inorganic IED residues.

  1. Characterization of nosocomial Serratia marcescens isolates: comparison of Fourier-transform infrared spectroscopy with pulsed-field gel electrophoresis of genomic DNA fragments and multilocus enzyme electrophoresis.

    Irmscher, H M; Fischer, R; Beer, W; Seltmann, G


    A total of 66 Serratia marcescens isolates from 46 patients was investigated by macrorestriction using XbaI followed by pulsed-field gel electrophoresis. 7 restriction fragment patterns attributable to more than one patient and 9 individual patterns were identified. The isolates were additionally characterized by multilocus enzyme electrophoresis and Fourier-transform infrared spectroscopy. The macrorestriction patterns and the multilocus enzyme electrophoresis patterns corresponded fairly well while the classifications derived from these methods were not completely congruent. The grouping achieved by Fourier-transform infrared spectroscopy on the basis of high (> 1000) and moderately high heterogeneity values (300) was consistent with the macrorestriction results. Grouping on a lower heterogeneity level did not contribute to further discrimination. In general, Fourier-transform infrared spectroscopy was less discriminatory than the two other methods, but easier to perform. Therefore, laboratories equipped with the necessary devices may use it to rapidly select bacterial isolates for macrorestriction or other well established characterization procedures.

  2. Ink-native electrophoresis: an alternative to blue-native electrophoresis more suitable for in-gel detection of enzymatic activity.

    Kaneko, Keisuke; Sueyoshi, Noriyuki; Kameshita, Isamu; Ishida, Atsuhiko


    Blue-native electrophoresis (BNE) is a useful technique for analyzing protein complexes, but the Coomassie brilliant blue (CBB) dye used in BNE often hampers in-gel detection of enzymatic activity. Here we report an improved method, termed ink-native electrophoresis (INE), in which Pelikan 4001 fountain pen ink is used as a charge-shifting agent instead of CBB. INE is more suitable than BNE for in-gel detection of protein kinase activity after polyacrylamide gel electrophoresis (PAGE), and its performance in protein complex separation is comparable to that of conventional BNE. INE may provide a powerful tool to isolate and analyze various protein complexes. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry.

    Váradi, Csaba; Mittermayr, Stefan; Millán-Martín, Silvia; Bones, Jonathan


    Capillary electrophoresis (CE) offers excellent efficiency and orthogonality to liquid chromatographic (LC) separations for oligosaccharide structural analysis. Combination of CE with high resolution mass spectrometry (MS) for glycan analysis remains a challenging task due to the MS incompatibility of background electrolyte buffers and additives commonly used in offline CE separations. Here, a novel method is presented for the analysis of 2-aminobenzoic acid (2-AA) labelled glycans by capillary electrophoresis coupled to mass spectrometry (CE-MS). To ensure maximum resolution and excellent precision without the requirement for excessive analysis times, CE separation conditions including the concentration and pH of the background electrolyte, the effect of applied pressure on the capillary inlet and the capillary length were evaluated. Using readily available (12/13)C6 stable isotopologues of 2-AA, the developed method can be applied for quantitative glycan profiling in a twoplex manner based on the generation of extracted ion electropherograms (EIE) for (12)C6 'light' and (13)C6 'heavy' 2-AA labelled glycan isotope clusters. The twoplex quantitative CE-MS glycan analysis platform is ideally suited for comparability assessment of biopharmaceuticals, such as monoclonal antibodies, for differential glycomic analysis of clinical material for potential biomarker discovery or for quantitative microheterogeneity analysis of different glycosylation sites within a glycoprotein. Additionally, due to the low injection volume requirements of CE, subsequent LC-MS analysis of the same sample can be performed facilitating the use of orthogonal separation techniques for structural elucidation or verification of quantitative performance.

  4. Antioxidant effects of carnitine supplementation on 14-3-3 protein isoforms in the aged rat hippocampus detected using fully automated two-dimensional chip gel electrophoresis.

    Iwamoto, M; Miura, Y; Tsumoto, H; Tanaka, Y; Morisawa, H; Endo, T; Toda, T


    We here described the antioxidant effects of carnitine supplementation on 14-3-3 protein isoforms in the aged rat hippocampus detected using the fully automated two-dimensional chip gel electrophoresis system (Auto2D). This system was easy and convenient to use, and the resolution obtained was more sensitive and higher than that of conventional two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). We separated and identified five isoforms of the 14-3-3 protein (beta/alpha, gamma, epsilon, zeta/delta, and eta) using the Auto2D system. We then examined the antioxidant effects of carnitine supplementation on the protein profiles of the cytosolic fraction in the aged rat hippocampus, demonstrating that carnitine supplementation suppressed the oxidation of methionine residues in these isoforms. Since methionine residues are easily oxidized to methionine sulfoxide, the convenient and high-resolution 2-D PAGE system can be available to analyze methionine oxidation avoiding artifactual oxidation. We showed here that the Auto2D system was a very useful tool for studying antioxidant effects through proteomic analysis of protein oxidation.

  5. Direct methods for dynamic monitoring of secretions from single cells by capillary electrophoresis and microscopy with laser-induced native fluorescence detection

    Tong, W.


    Microscale separation and detection methods for real-time monitoring of dynamic cellular processes (e.g., secretion) by capillary electrophoresis (CE) and microscopic imaging were developed. Ultraviolet laser-induced native fluorescence (LINF) provides simple, sensitive and direct detection of neurotransmitters and proteins without any derivatization. An on-column CE-LINF protocol for quantification of the release from single cell was demonstrated. Quantitative measurements of both the amount of insulin released from and the amount remaining in the cell ({beta}TC3) were achieved simultaneously. Secretion of catecholamines (norepinephrine (NE) and epinephrine (E)) from individual bovine adrenal chromaffin cells was determined using the on-column CE-LINF. Direct visualization of the secretion process of individual bovine adrenal chromaffin cells was achieved by LINF imaging microscopy with high temporal and spatial resolution. The secretion of serotonin from individual leech Retzius neurons was directly characterized by LINF microscopy with high spatial resolution.

  6. Direct methods for dynamic monitoring of secretions from single cells by capillary electrophoresis and microscopy with laser-induced native fluorescence detection

    Tong, Wei [Iowa State Univ., Ames, IA (United States)


    Microscale separation and detection methods for real-time monitoring of dynamic cellular processes (e.g., secretion) by capillary electrophoresis (CE) and microscopic imaging were developed. Ultraviolet laser-induced native fluorescence (LINF) provides simple, sensitive and direct detection of neurotransmitters and proteins without any derivatization. An on-column CE-LINF protocol for quantification of the release from single cell was demonstrated. Quantitative measurements of both the amount of insulin released from and the amount remaining in the cell (βTC3) were achieved simultaneously. Secretion of catecholamines (norepinephrine (NE) and epinephrine (E)) from individual bovine adrenal chromaffin cells was determined using the on-column CE-LINF. Direct visualization of the secretion process of individual bovine adrenal chromaffin cells was achieved by LINF imaging microscopy with high temporal and spatial resolution. The secretion of serotonin from individual leech Retzius neurons was directly characterized by LINF microscopy with high spatial resolution.

  7. Analysis of Soluble Proteins in Natural Cordyceps sinensis from Different Producing Areas by Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis and Two-dimensional Electrophoresis.

    Li, Chun-Hong; Zuo, Hua-Li; Zhang, Qian; Wang, Feng-Qin; Hu, Yuan-Jia; Qian, Zheng-Ming; Li, Wen-Jia; Xia, Zhi-Ning; Yang, Feng-Qing


    As one of the bioactive components in Cordyceps sinensis (CS), proteins were rarely used as index components to study the correlation between the protein components and producing areas of natural CS. Protein components of 26 natural CS samples produced in Qinghai, Tibet, and Sichuan provinces were analyzed and compared to investigate the relationship among 26 different producing areas. Proteins from 26 different producing areas were extracted by Tris-HCl buffer with Triton X-100, and separated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and two-dimensional electrophoresis (2-DE). The SDS-PAGE results indicated that the number of protein bands and optical density curves of proteins in 26 CS samples was a bit different. However, the 2-DE results showed that the numbers and abundance of protein spots in protein profiles of 26 samples were obviously different and showed certain association with producing areas. Based on the expression values of matched protein spots, 26 batches of CS samples can be divided into two main categories (Tibet and Qinghai) by hierarchical cluster analysis. The number of protein bands and optical density curves of proteins in 26 Cordyceps sinensis samples were a bit different on the sodium dodecyl sulfate-polyacrylamide gel electrophoresis protein profilesNumbers and abundance of protein spots in protein profiles of 26 samples were obvious different on two-dimensional electrophoresis mapsTwenty-six different producing areas of natural Cordyceps sinensis samples were divided into two main categories (Tibet and Qinghai) by Hierarchical cluster analysis based on the values of matched protein spots. Abbreviations Used: SDS-PAGE: Sodium dodecyl sulfate polyacrylamide gel electrophoresis, 2-DE: Two-dimensional electrophoresis, Cordyceps sinensis: CS, TCMs: Traditional Chinese medicines.

  8. Combined use of ionic liquid and hydroxypropyl-β-cyclodextrin for the enantioseparation of ten drugs by capillary electrophoresis.

    Cui, Yan; Ma, Xiaowei; Zhao, Min; Jiang, Zhen; Xu, Shuying; Guo, Xingjie


    In the present study, hydroxypropyl-β-cyclodextrin and an ionic liquid (1-ethyl-3-methylimidazolium-l-lactate) were used as additives in capillary electrophoresis for the enantioseparation of 10 analytes, including ofloxacin, propranolol hydrochloride, dioxopromethazine hydrochloride, isoprenaline hydrochloride, chlorpheniramine maleate, liarozole, tropicamide, amlodipine benzenesulfonate, brompheniramine maleate, and homatropine methylbromide. The effects of ionic liquid concentrations, salt effect, cations, and anions of ionic liquids on enantioseparation were investigated and the results proved that there was a synergistic effect between hydroxypropyl-β-cyclodextrin and the ionic liquid, and the cationic part of the ionic liquid played an important role in the increased resolution. With the developed dual system, all the enantiomers of 10 analytes were well separated in resolutions of 5.35, 1.76, 1.85, 2.48, 2.88, 1.43, 5.45, 4.35, 2.76, and 2.98, respectively. In addition, the proposed method was applied to the determination of the enantiomeric purity of S-ofloxacin after validation of the method in terms of selectivity, repeatability, linearity range, accuracy, precision, limit of detection (LOD), and limit of quality (LOQ).

  9. Denaturing gradient gel electrophoresis profiling of bacterial communities composition in Arabian Sea

    Singh, S.K.; Ramaiah, N.

    Denaturing gradient gel electrophoresis (DGGE) was used to elucidate spatial and temporal variations in bacterial community composition (BCC) from four locations along the central west coast of India. DNA extracts from 36 water samples collected...

  10. Determination of Size Distribution of Nano-particles by Capillary Zone Electrophoresis

    Yan XUE; Hai Ying YANG; Yong Tan YANG


    A new method was developed for the determination of the size distribution of nano-particles by capillary zone electrophoresis (CZE). Scattering effect of nanoparticles was studied. This method for the determination of size distribution was statistical.


    The enantiomers of five chiral pesticides of environmental interest, metalaxyl, imazaquin, fonofos (dyfonate), ruelene (cruformate) and dichlorprop, were separated analytically using capillary electrophoresis (CE) with cyclodextrin chiral selectors. CE is shown to be a simple, ef...

  12. Amplified fragment length polymorphism and pulsed field gel electrophoresis for subspecies differentiation of Serpulina pilosicoli

    Møller, Kristian; Jensen, Tim Kåre; Boye, Mette


    Pulsed field gel electrophoresis (PFGE) and amplified fragment length polymorphism (AFLP) were compared for their ability to differentiate between 50 porcine Serpulina pilosicoli isolates. Both techniques were highly sensitive, dividing the isolates into 36 and 38 groups, respectively. Due...

  13. Charge heterogeneity study of a Fc-fusion protein, abatacept, using two-dimensional gel electrophoresis.

    Nebija, D; Noe, C R; Lachmann, B


    Medicinal products obtained by recombinant DNA technology are complex molecules and demonstrate a high degree of molecular heterogeneity. Charge heterogeneity and isoform pattern of this class of medicines, are parameters important for their quality, safety, and efficacy. In this study we report the application of two-dimensional gel electrophoresis (2-D electrophoresis) for the quality assessment, identification, charge heterogeneity and isoform pattern study of recombinant protein, CTLA4-Ig (abatacept), which has been selected as an example of the drug class, known as Fc-fusion proteins. In order to achieve an efficient separation of this complex analyte,2-D electrophoresis was optimized employing different experimental conditions regarding the selection of an immobilized pH gradient (IPG), sample pretreatment, presentation and detection procedure. Experimental datadocumented that 2-D electrophoresis is a suitable method for the assessment of identity, purity, structural integrity, isoform pattern and to monitor charge heterogeneity and post-translational glycosylation of the Fc-fusion protein, abatacept.

  14. Development of bufferless gel electrophoresis chip for easy preparation and rapid DNA separation.

    Oleksandrov, Sergiy; Aman, Abdurazak; Lim, Wanyoung; Kim, Younghee; Bae, Nam Ho; Lee, Kyoung G; Lee, Seok Jae; Park, Sungsu


    This work presents a handy, fast, and compact bufferless gel electrophoresis chip (BGEC), which consists of precast agarose gel confined in a disposable plastic body with electrodes. It does not require large volumes of buffer to fill reservoirs, or the process of immersing the gel in the buffer. It withstands voltages up to 28.4 V/cm, thereby allowing DNA separation within 10 minutes with a similar separation capability to the standard gel electrophoresis. The results suggest that our BGEC is highly suitable for in situ gel electrophoresis in forensic, epidemiological settings and crime scenes where standard gel electrophoresis equipment cannot be brought in while quick results are needed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Trace analysis of organic ions in ice samples by capillary electrophoresis

    Huber, T. [Bern Univ. (Switzerland); Schwikowski, M.; Gaeggeler, H.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)


    Capillary electrophoresis was tested as a new analytical method for ice samples. Comparisons to ion chromatography were made concerning accuracy, detection limits, reproducibility, necessary sample volume and time consumption. (author) 1 fig., 3 refs.

  16. Applications of on-line weak affinity interactions in free solution capillary electrophoresis

    Heegaard, Niels H H; Nissen, Mogens H; Chen, David D Y


    The impressive selectivity offered by capillary electrophoresis can in some cases be further increased when ligands or additives that engage in weak affinity interactions with one or more of the separated analytes are added to the electrophoresis buffer. This on-line affinity capillary...... enantiomers and on using capillary electrophoresis to characterize such interactions quantitatively. We describe the equations for binding isotherms, illustrate how selectivity can be manipulated by varying the additive concentrations, and show how the methods may be used to estimate binding constants. On......-line affinity capillary electrophoresis methods are especially valuable for enantiomeric separations and for functional characterization of the contents of biological samples that are only available in minute quantities....


    The generic method described here involves typical capillary electrophoresis (CE) techniques, with the addition of cyclodextrin chiral selectors to the electrolyte for enantiomer separation and also, in the case of neutral analytes, the further addition of a micelle forming comp...

  18. Enzymatic membranes for the selective transport of neutral molecules by electrophoresis.

    Perrin, Bernard; Couturier, Roger; Fiaty, Koffi; Charcosset, Catherine; Maïsterrena, Bernard


    The active and selective transport of glucose and glycerol was carried out using electrophoresis and artificial enzymatic membranes. These positively charged composite membranes carry, on the face adjacent to the donor compartment of an electrophoresis module, a specific kinase (hexokinase or glycerokinase) and, on the opposite face, an alkaline phosphatase (ALP). Phosphorylation of the neutral substrate (glucose or glycerol) on the donor side by the kinase generates a negatively charged phosphorylated substrate, whose transmembrane migration is promoted by an electric field and by the membrane's positive charge. Dephosphorylation of the phosphorylated substrate by ALP on the opposite face regenerates the neutral substrate, which accumulates in the receiver compartment of the electrophoresis module. Using an electrophoresis module specifically designed for this study, our experiments were carried out enabling glucose and glycerol to be concentrated approximately eight- and twelve-fold, respectively, in 8 h.

  19. Synthesis and Characterization of Water-Soluble Carboxymethyl-Cyclodextrin Polymer as Capillary Electrophoresis Chiral Selector


    The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector.Verrapamil and thiopentorusodium were well separated using CM-CD polymer as chiral selector.

  20. p-Hydrazinobenzenesulfonic Acid Derivatives of Carbohydrates and Their Capillary Zone Electrophoresis


    p-Hydrazinobenzenesulfonic acid is explored as a novel ultraviolet labeling reagent for capillary electrophoresis (CE) of mono- and disaccharides. The labeling reaction takes less than 10 minutes and introduces both of absorption and charge groups into the sugars.

  1. Electrophoresis tests on STS-3 and ground control experiments - A basis for future biological sample selections

    Morrison, D. R.; Lewis, M. L.


    Static zone electrophoresis is an electrokinetic method of separating macromolecules and small particles. However, its application for the isolation of biological cells and concentrated protein solutions is limited by sedimentation and convection. Microgravity eliminates or reduces sedimentation, floatation, and density-driven convection arising from either Joule heating or concentration differences. The advantages of such an environment were first demonstrated in space during the Apollo 14 and 16 missions. In 1975 the Electrophoresis Technology Experiment (MA-011) was conducted during the Apollo-Soyuz Test Project flight. In 1979 a project was initiated to repeat the separations of human kidney cells. One of the major objectives of the Electrophoresis Equipment Verification Tests (EEVT) on STS-3 was to repeat and thereby validate the first successful electrophoretic separation of human kidney cells. Attention is given to the EEVT apparatus, the preflight electrophoresis, and inflight operational results.

  2. A microdestructive capillary electrophoresis method for the analysis of blue-pen-ink strokes on office paper.

    Calcerrada, Matías; González-Herráez, Miguel; Garcia-Ruiz, Carmen


    This manuscript describes the development of a capillary electrophoresis (CE) method for the detection of acid and basic dyes and its application to real samples, blue-pen-ink strokes on office paper. First, a capillary zone electrophoresis (CZE) method was developed for the separation of basic and acid dyes, by studying the separation medium (buffer nature, pH and relative amount of additive) and instrumental parameters (temperature, voltage and capillary dimensions). The method performance was evaluated in terms of selectivity, resolution (above 5 and 2 for acid dyes and basic dyes, respectively, except for two basic dye standards), LOD (lower than 0.4 mg/L) and precision as intraday and interday RSD values of peak migration times (lower than 0.6%). The developed method was then applied to 34 blue pens from different technologies (rollerball, ballpoint, markers) and with different ink composition (gel, water-based, oil-based). A microdestructive sample treatment using a scalpel to scratch 0.3mg of ink stroke was performed. The entire electropherogram profile allowed the visual discrimination between different types of ink and brands, being not necessary a statistical treatment. A 100% of discrimination was achieved between pen technologies, brands, and models, although non-reproducible zones in the electropherograms were found for blue gel pen samples. The two different batches of blue oil-based pens were also differentiated. Thus, this method provides a simple, microdestructive, and rapid analysis of different blue pen technologies which may complement the current analysis of questioned documents performed by forensic laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Developments in and applications of capillary electrophoresis inductively coupled plasma mass spectrometry

    Taylor, K.A


    This project has set out to design and optimise a robust and efficient interface for capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) and to investigate the application of the technique in elemental speciation studies. An interface was constructed using a commercial microconcentric nebuliser (MCN) and a cyclonic spray chamber. The cyclonic spray chamber was designed specifically to provide rapid sample response and washout and to minimise sample dispersion. Isoforms of the heavy metal binding protein, metallothionein, were separated and the bound metals detected to characterise the interface. Suction from the self-aspirating nebuliser was identified as the principal factor controlling electrophoretic resolution. To maintain resolution, two methods for counterbalancing the nebuliser suction were investigated. In the first method an optimised make-up flow was employed, and in the second a negative pressure was applied to the buffer vial during the separation. The negative pressure method was preferred because it did not significantly compromise sensitivity. The MCN was found to be prone to regular blocking which compromised the analytical precision of the system. A second interface was constructed using a glass MicroMist nebuliser. The MicroMist nebuliser was found to be less prone to blocking than the MCN and significantly improved the precision of the system to less than 4.3% RSD. The MicroMist nebuliser did, however, provide a lower sensitivity. The advantage of employing an electroosmotic flow marker to correct for migration time drifts was demonstrated. A CE-ICP-MS method was developed for the speciation of selenium in selenium enriched yeasts and nutritional supplements. Selenoamino acids and inorganic selenium species were separated, as anions, under strong electroosmotic flow conditions. Methods to enhance the selenium sensitivity were investigated. A proteolytic enzyme extraction method was employed and the effect of the

  4. 3D Printed Micro Free-Flow Electrophoresis Device.

    Anciaux, Sarah K; Geiger, Matthew; Bowser, Michael T


    The cost, time, and restrictions on creative flexibility associated with current fabrication methods present significant challenges in the development and application of microfluidic devices. Additive manufacturing, also referred to as three-dimensional (3D) printing, provides many advantages over existing methods. With 3D printing, devices can be made in a cost-effective manner with the ability to rapidly prototype new designs. We have fabricated a micro free-flow electrophoresis (μFFE) device using a low-cost, consumer-grade 3D printer. Test prints were performed to determine the minimum feature sizes that could be reproducibly produced using 3D printing fabrication. Microfluidic ridges could be fabricated with dimensions as small as 20 μm high × 640 μm wide. Minimum valley dimensions were 30 μm wide × 130 μm wide. An acetone vapor bath was used to smooth acrylonitrile-butadiene-styrene (ABS) surfaces and facilitate bonding of fully enclosed channels. The surfaces of the 3D-printed features were profiled and compared to a similar device fabricated in a glass substrate. Stable stream profiles were obtained in a 3D-printed μFFE device. Separations of fluorescent dyes in the 3D-printed device and its glass counterpart were comparable. A μFFE separation of myoglobin and cytochrome c was also demonstrated on a 3D-printed device. Limits of detection for rhodamine 110 were determined to be 2 and 0.3 nM for the 3D-printed and glass devices, respectively.

  5. Weakly nonlinear electrophoresis of a highly charged colloidal particle

    Schnitzer, Ory; Zeyde, Roman; Yavneh, Irad; Yariv, Ehud


    At large zeta potentials, surface conduction becomes appreciable in thin-double-layer electrokinetic transport. In the linear weak-field regime, where this effect is quantified by the Dukhin number, it is manifested in non-Smoluchowski electrophoretic mobilities. In this paper we go beyond linear response, employing the recently derived macroscale model of Schnitzer and Yariv ["Macroscale description of electrokinetic flows at large zeta potentials: Nonlinear surface conduction," Phys. Rev. E 86, 021503 (2012), 10.1103/PhysRevE.86.021503] as the infrastructure for a weakly nonlinear analysis of spherical-particle electrophoresis. A straightforward perturbation in the field strength is frustrated by the failure to satisfy the far-field conditions, representing a non-uniformity of the weak-field approximation at large distances away from the particle, where salt advection becomes comparable to diffusion. This is remedied using inner-outer asymptotic expansions in the spirit of Acrivos and Taylor ["Heat and mass transfer from single spheres in Stokes flow," Phys. Fluids 5, 387 (1962), 10.1063/1.1706630], with the inner region representing the particle neighborhood and the outer region corresponding to distances scaling inversely with the field magnitude. This singular scheme furnishes an asymptotic correction to the electrophoretic velocity, proportional to the applied field cubed, which embodies a host of nonlinear mechanisms unfamiliar from linear electrokinetic theories. These include the effect of induced zeta-potential inhomogeneity, animated by concentration polarization, on electro-osmosis and diffuso-osmosis; bulk advection of salt; nonuniform bulk conductivity; Coulomb body forces acting on bulk volumetric charge; and the nonzero electrostatic force exerted upon the otherwise screened particle-layer system. A numerical solution of the macroscale model validates our weakly nonlinear analysis.

  6. A versatile polyacrylamide gel electrophoresis based sulfotransferase assay

    Prather Brittany


    Full Text Available Abstract Background Sulfotransferases are a large group of enzymes that regulate the biological activity or availability of a wide spectrum of substrates through sulfation with the sulfur donor 3'-phosphoadenosine-5'-phosphosulfate (PAPS. These enzymes are known to be difficult to assay. A convenient assay is needed in order to better understand these enzymes. Results A universal sulfotransferase assay method based on sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE is described. This assay has been successfully applied to substrates as small as α-naphthol and as big as proteoglycans. As examples, we present the assays for recombinant human CHST4, TPST1, CHST3 and HS6ST1. In order to assess whether a small molecule can be applicable to this type of assay, a method to estimate the relative mobility of a molecule to PAPS is also presented. The estimated relative mobilities of various sulfated small molecules generated by SULT1A1, SULT1E1, SULT2A1 and CHST4 are in the range of ± 0.2 of the actual relative mobilities. Conclusion The versatility of the current method comes from the ability that SDS-PAGE can separate proteins and small molecules according to different parameters. While mobilities of proteins during SDS-PAGE are inversely related to their sizes, mobilities of small molecules are positively related to their charge/mass ratios. The predicted relative mobility of a product to PAPS is a good indicator of whether a sulfotransferase can be assayed with SDS-PAGE. Because phosphorylation is most similar to sulfation in chemistry, the method is likely to be applicable to kinases as well.

  7. Insight of Saffron Proteome by Gel-Electrophoresis.

    Paredi, Gianluca; Raboni, Samanta; Marchesani, Francesco; Ordoudi, Stella A; Tsimidou, Maria Z; Mozzarelli, Andrea


    Saffron is a spice comprised of the dried stigmas and styles of Crocus sativus L. flowers and, since it is very expensive, it is frequently adulterated. So far, proteomic tools have never been applied to characterize the proteome of saffron or identify possible cases of fraud. In this study, 1D-Gel Electrophoresis was carried out to characterize the protein profile of (i) fresh stigmas and styles of the plant; (ii) dried stigmas and styles from different geographical origins (Spanish, Italian, Greek and Iranian) that had been stored for various periods of time after their processing; and (iii) two common plant adulterants, dried petals of Carthamus tinctorius L. and dried fruits of Gardenia jasminoides Ellis. A selective protein extraction protocol was applied to avoid interference from colored saffron metabolites, such as crocins, during electrophoretic analyses of saffron. We succeeded in separating and assigning the molecular weights to more than 20 proteins. In spite of the unavailability of the genome of saffron, we were able to identify five proteins by Peptide Mass Fingerprinting: phosphoenolpyruvate carboxylase 3, heat shock cognate 70 KDa protein, crocetin glucosyltransferase 2, α-1,4-glucan-protein synthase and glyceraldehydes-3-phosphate dehydrogenase-2. Our findings indicate that (i) few bands are present in all saffron samples independently of origin and storage time, with amounts that significantly vary among samples and (ii) aging during saffron storage is associated with a reduction in the number of detectable bands, suggesting that proteases are still active. The protein pattern of saffron was quite distinct from those of two common adulterants, such as the dried petals of Carthamus tinctorius and the dried fruits of Gardenia jasminoides indicating that proteomic analyses could be exploited for detecting possible frauds.

  8. Insight of Saffron Proteome by Gel-Electrophoresis

    Gianluca Paredi


    Full Text Available Saffron is a spice comprised of the dried stigmas and styles of Crocus sativus L. flowers and, since it is very expensive, it is frequently adulterated. So far, proteomic tools have never been applied to characterize the proteome of saffron or identify possible cases of fraud. In this study, 1D-Gel Electrophoresis was carried out to characterize the protein profile of (i fresh stigmas and styles of the plant; (ii dried stigmas and styles from different geographical origins (Spanish, Italian, Greek and Iranian that had been stored for various periods of time after their processing; and (iii two common plant adulterants, dried petals of Carthamus tinctorius L. and dried fruits of Gardenia jasminoides Ellis. A selective protein extraction protocol was applied to avoid interference from colored saffron metabolites, such as crocins, during electrophoretic analyses of saffron. We succeeded in separating and assigning the molecular weights to more than 20 proteins. In spite of the unavailability of the genome of saffron, we were able to identify five proteins by Peptide Mass Fingerprinting: phosphoenolpyruvate carboxylase 3, heat shock cognate 70 KDa protein, crocetin glucosyltransferase 2, α-1,4-glucan-protein synthase and glyceraldehydes-3-phosphate dehydrogenase-2. Our findings indicate that (i few bands are present in all saffron samples independently of origin and storage time, with amounts that significantly vary among samples and (ii aging during saffron storage is associated with a reduction in the number of detectable bands, suggesting that proteases are still active. The protein pattern of saffron was quite distinct from those of two common adulterants, such as the dried petals of Carthamus tinctorius and the dried fruits of Gardenia jasminoides indicating that proteomic analyses could be exploited for detecting possible frauds.

  9. Analysis of Dictyostelium discoideum Inositol Pyrophosphate Metabolism by Gel Electrophoresis

    Pisani, Francesca; Livermore, Thomas; Rose, Giuseppina; Chubb, Jonathan Robert; Gaspari, Marco; Saiardi, Adolfo


    The social amoeba Dictyostelium discoideum was instrumental in the discovery and early characterization of inositol pyrophosphates, a class of molecules possessing highly-energetic pyrophosphate bonds. Inositol pyrophosphates regulate diverse biological processes and are attracting attention due to their ability to control energy metabolism and insulin signalling. However, inositol pyrophosphate research has been hampered by the lack of simple experimental procedures to study them. The recent development of polyacrylamide gel electrophoresis (PAGE) and simple staining to resolve and detect inositol pyrophosphate species has opened new investigative possibilities. This technology is now commonly applied to study in vitro enzymatic reactions. Here we employ PAGE technology to characterize the D. discoideum inositol pyrophosphate metabolism. Surprisingly, only three major bands are detectable after resolving acidic extract on PAGE. We have demonstrated that these three bands correspond to inositol hexakisphosphate (IP6 or Phytic acid) and its derivative inositol pyrophosphates, IP7 and IP8. Biochemical analyses and genetic evidence were used to establish the genuine inositol phosphate nature of these bands. We also identified IP9 in D. discoideum cells, a molecule so far detected only from in vitro biochemical reactions. Furthermore, we discovered that this amoeba possesses three different inositol pentakisphosphates (IP5) isomers, which are largely metabolised to inositol pyrophosphates. Comparison of PAGE with traditional Sax-HPLC revealed an underestimation of the cellular abundance of inositol pyrophosphates by traditional methods. In fact our study revealed much higher levels of inositol pyrophosphates in D. discoideum in the vegetative state than previously detected. A three-fold increase in IP8 was observed during development of D. discoideum a value lower that previously reported. Analysis of inositol pyrophosphate metabolism using ip6k null amoeba revealed

  10. Analysis of Dictyostelium discoideum inositol pyrophosphate metabolism by gel electrophoresis.

    Pisani, Francesca; Livermore, Thomas; Rose, Giuseppina; Chubb, Jonathan Robert; Gaspari, Marco; Saiardi, Adolfo


    The social amoeba Dictyostelium discoideum was instrumental in the discovery and early characterization of inositol pyrophosphates, a class of molecules possessing highly-energetic pyrophosphate bonds. Inositol pyrophosphates regulate diverse biological processes and are attracting attention due to their ability to control energy metabolism and insulin signalling. However, inositol pyrophosphate research has been hampered by the lack of simple experimental procedures to study them. The recent development of polyacrylamide gel electrophoresis (PAGE) and simple staining to resolve and detect inositol pyrophosphate species has opened new investigative possibilities. This technology is now commonly applied to study in vitro enzymatic reactions. Here we employ PAGE technology to characterize the D. discoideum inositol pyrophosphate metabolism. Surprisingly, only three major bands are detectable after resolving acidic extract on PAGE. We have demonstrated that these three bands correspond to inositol hexakisphosphate (IP₆ or Phytic acid) and its derivative inositol pyrophosphates, IP₇ and IP₈. Biochemical analyses and genetic evidence were used to establish the genuine inositol phosphate nature of these bands. We also identified IP₉ in D. discoideum cells, a molecule so far detected only from in vitro biochemical reactions. Furthermore, we discovered that this amoeba possesses three different inositol pentakisphosphates (IP₅) isomers, which are largely metabolised to inositol pyrophosphates. Comparison of PAGE with traditional Sax-HPLC revealed an underestimation of the cellular abundance of inositol pyrophosphates by traditional methods. In fact our study revealed much higher levels of inositol pyrophosphates in D. discoideum in the vegetative state than previously detected. A three-fold increase in IP₈ was observed during development of D. discoideum a value lower that previously reported. Analysis of inositol pyrophosphate metabolism using ip6k null amoeba

  11. Analysis of Dictyostelium discoideum inositol pyrophosphate metabolism by gel electrophoresis.

    Francesca Pisani

    Full Text Available The social amoeba Dictyostelium discoideum was instrumental in the discovery and early characterization of inositol pyrophosphates, a class of molecules possessing highly-energetic pyrophosphate bonds. Inositol pyrophosphates regulate diverse biological processes and are attracting attention due to their ability to control energy metabolism and insulin signalling. However, inositol pyrophosphate research has been hampered by the lack of simple experimental procedures to study them. The recent development of polyacrylamide gel electrophoresis (PAGE and simple staining to resolve and detect inositol pyrophosphate species has opened new investigative possibilities. This technology is now commonly applied to study in vitro enzymatic reactions. Here we employ PAGE technology to characterize the D. discoideum inositol pyrophosphate metabolism. Surprisingly, only three major bands are detectable after resolving acidic extract on PAGE. We have demonstrated that these three bands correspond to inositol hexakisphosphate (IP₆ or Phytic acid and its derivative inositol pyrophosphates, IP₇ and IP₈. Biochemical analyses and genetic evidence were used to establish the genuine inositol phosphate nature of these bands. We also identified IP₉ in D. discoideum cells, a molecule so far detected only from in vitro biochemical reactions. Furthermore, we discovered that this amoeba possesses three different inositol pentakisphosphates (IP₅ isomers, which are largely metabolised to inositol pyrophosphates. Comparison of PAGE with traditional Sax-HPLC revealed an underestimation of the cellular abundance of inositol pyrophosphates by traditional methods. In fact our study revealed much higher levels of inositol pyrophosphates in D. discoideum in the vegetative state than previously detected. A three-fold increase in IP₈ was observed during development of D. discoideum a value lower that previously reported. Analysis of inositol pyrophosphate metabolism using

  12. Protein expression on Cr resistant microorganism using electrophoresis method



    Full Text Available Fatmawati U, Suranto, Sajidan. 2009. Protein expression on Cr resistant microorganism using electrophoresis method. Nusantara Bioscience 1: 31-37. Hexavalent chromium (Cr(VI is known as toxic heavy metals, so the need is reduced to Cr(III is much less toxicity. Pseudomonas aeruginosa, Pseudomonas putida, Klebsiella pneumoniae, Pantoea sp. and Saccharomyces cerevisiae are resistant Cr(VI microorganism and have ability to reduce Cr(VI. The aim of this research is to know ability of microorganism to reduce Cr(VI and to know protein band pattern between Cr(VI resistant microorganism and non resistant microorganism which inoculated on LB broth. SDS-PAGE was used to indentify protein expression. While, Cr(VI concentration was identified by 1.5 diphenylcarbazide method. The quantitative data was analyzed by two factorial ANOVA that continued with DMRT at 1% level test. The qualitative data i.e. protein expression analyzed by relative mobility (Rf. The results showed that the ability of microorganisms to reduce Cr(VI at initial concentration of 0.5 ppm, 1 ppm, 5 ppm and 10 ppm may vary, the average percentage of the ability of each microorganism in reducing Cr(VI is P. putida (65% > S. cerevisiae (64.45% >. P. aeruginosa (60.73% > Pantoea sp. (50.22% > K. pneumoniae (47.82% > without microorganisms (34.25%. The adding microorganisms have significantly influenced toward reduction of Cr(VI. The SDS-PAGE shows that protein expression between resistant and not resistant microorganisms are no different, but resistant microorganisms have more protein (protein band is thicker.

  13. The application of single cell gel electrophoresis or comet assay to human monitoring studies

    Valverde Mahara


    Full Text Available Objective. In the search of new human genotoxic biomarkers, the single cell gel electrophoresis assay has been proposed as a sensible alternative. Material and methods. This technique detects principally single strand breaks as well as alkali-labile and repair-retarded sites. Results. Herein we present our experience using the single cell gel electrophoresis assay in human population studies, both occupationally and environmentally exposed. Conclusions. We discuss the assay feasibility as a genotoxic biomarker.

  14. The application of single cell gel electrophoresis or comet assay to human monitoring studies


    Objective. In the search of new human genotoxic biomarkers, the single cell gel electrophoresis assay has been proposed as a sensible alternative. Material and methods. This technique detects principally single strand breaks as well as alkali-labile and repair-retarded sites. Results. Herein we present our experience using the single cell gel electrophoresis assay in human population studies, both occupationally and environmentally exposed. Conclusions. We discuss the assay feasibility as a g...

  15. Affinity Probe Capillary Electrophoresis Evaluation of Aptamer Binding to Campylobacter jejuni Bacteria


    Affinity Probe Capillary Electrophoresis Evaluation of Aptamer Binding to Campylobacter jejuni Bacteria by Dimitra N. Stratis-Cullum, Sun...Aptamer Binding to Campylobacter jejuni Bacteria Dimitra N. Stratis-Cullum, Sun McMasters, and Paul M. Pellegrino Sensors and Electron Devices...To) 2007–2008 4. TITLE AND SUBTITLE Affinity Probe Capillary Electrophoresis Evaluation of Aptamer Binding to Campylobacter jejuni Bacteria 5a

  16. Affinity capillary electrophoresis method for investigation of bile salts complexation with sulfobutyl ether-ß-cyclodextrin

    Østergaard, Jesper; Jensen, Henrik; Holm, Rene


    an influence on the ionic strength of the background electrolyte when the cyclodextrin is used in capillary electrophoresis. Mobility-shift affinity capillary methods for investigation of the complexation of taurocholate and taurochenodeoxycholate with the negatively charged cyclodextrin derivative applying...... constant power and ionic strength conditions as well as constant voltage and varying ionic strength were investigated. A new approach for the correction of background electrolyte ionic strength was developed. Mobility-shift affinity capillary electrophoresis experiments obtained at constant voltage...

  17. Role of capillary electrophoresis in the fight against doping in sports.

    Harrison, Christopher R


    At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.

  18. Two previously undetected variants of glutamic-pyruvic transaminase found by acidic polyacrylamide gel electrophoresis.

    McLellan, T


    Two new electrophoretic variants of glutamic-pyruvic transaminase (GPT) have been found by polyacrylamide gel electrophoresis at acidic pH. They appeared to represent a single allele, GPT 2, by the standard method of starch gel electrophoresis. Studies in families show that they are inherited as codominant alleles at the GPT locus. Population frequencies are about the same as those of other rare GPT variants. Their behavior on gels is consistent with both of them having substitutions of histi...

  19. High-resolution differentiation of cyanobacteria by using rRNA-Internal Transcribed Spacer denaturing gradient gel electrophoresis

    Janse, I.; Meima, M.; Kardinaal, W.E.A.; Zwart, G.


    For many ecological studies of cyanobacteria, it is essential that closely related species or strains can be discriminated. Since this is often not possible by using morphological features, cyanobacteria are frequently studied by using DNA-based methods. A powerful method for analysis of the diversi

  20. Potential of vancomycin for the enantiomeric resolution of FMOC-amino acids by capillary electrophoresis-ion-trap-mass spectrometry.

    Sánchez-Hernández, Laura; Domínguez-Vega, Elena; Montealegre, Cristina; Castro-Puyana, María; Marina, María Luisa; Crego, Antonio L


    The potential of the antibiotic vancomycin (VC) as chiral selector for the enantiomeric separation of amino acids by CE-ESI-MS/MS² was investigated for the first time in this work. Derivatization of amino acids with FMOC-Cl was carried out to enable their interaction with VC as well as the formation of precursor ions with larger m/z which were employed in MS² experiments. The partial filling of a coated capillary was employed to avoid the loss in MS sensitivity originated by the introduction of VC in the ionization source. Under optimized conditions, the simultaneous enantiomeric separation and unequivocal identification of 17 amino acids (two of them being nonprotein amino acids) took place in about 20 min with LODs in the micromolar range.

  1. Super-resolution

    Nasrollahi, Kamal; Moeslund, Thomas B.


    Super-resolution, the process of obtaining one or more high-resolution images from one or more low-resolution observations, has been a very attractive research topic over the last two decades. It has found practical applications in many real world problems in different fields, from satellite...... the contributions of different authors to the basic concepts of each group. Furthermore, common issues in super-resolution algorithms, such as imaging models and registration algorithms, optimization of the cost functions employed, dealing with color information, improvement factors, assessment of super...

  2. Impact of capillary conditioning and background electrolyte composition on capillary electrophoresis analysis of prostate specific antigen isoforms.

    Farina-Gomez, Noemi; Puerta, Angel; Gonzalez, Monica; Diez-Masa, Jose Carlos; de Frutos, Mercedes


    Glycoproteins expressed in the human body can experience modifications as result of pathological situations. Detection of those changes can be useful as disease biomarkers. As a result of these modifications, size and/or electrical charge of the glycoprotein can be altered. Migration in capillary zone electrophoresis (CZE) is governed by the size to charge ratio of the analyte and therefore this separation technique can be used to monitor those modifications. At its turn, the alteration of the electrophoretical pattern of a given glycoprotein could be used as disease biomarker. To this aim, high repeatability for separation of a large number of peaks for a given glycoprotein is desirable. For prostate cancer, new markers are needed to decrease the high number of false positive results provided by the biomarkers currently used in clinics. In this sense, CZE methods for analysis of the several prostate specific antigen (PSA) peaks which this glycoprotein exhibit, called isoforms and containing one or more glycoforms, could be useful to study the PSA pattern as prostate cancer marker. In this study two complementary strategies to achieve both lot-to-lot capillary repeatability and high resolution of a large number of PSA isoforms are developed. Better performance and precision have been obtained for capillaries conditioned with HCl than for those conditioned with NaOH. Optimization of the background electrolyte (BGE) pH value to 8.0 and inclusion of 3M urea on its composition were the two factors of highest impact for enhancing resolution of the highest number of PSA peaks. Under the optimized conditions for capillary conditioning and BGE pH and composition, long-term resolution of 10 isoforms of PSA was achieved. Inter-day (n=3) %RSD was 0.55 for the ratio tm/tEOF, 1.15 for μeff, and 5.02 for % Acorr of the PSA peaks.

  3. Super-resolution

    Nasrollahi, Kamal; Moeslund, Thomas B.


    and aerial imaging to medical image processing, to facial image analysis, text image analysis, sign and number plates reading, and biometrics recognition, to name a few. This has resulted in many research papers, each developing a new super-resolution algorithm for a specific purpose. The current......Super-resolution, the process of obtaining one or more high-resolution images from one or more low-resolution observations, has been a very attractive research topic over the last two decades. It has found practical applications in many real world problems in different fields, from satellite...... the contributions of different authors to the basic concepts of each group. Furthermore, common issues in super-resolution algorithms, such as imaging models and registration algorithms, optimization of the cost functions employed, dealing with color information, improvement factors, assessment of super...

  4. Bank Resolution in Europe

    N. Gordon, Jeffery; Ringe, Georg


    Bank resolution is a key pillar of the European Banking Union. This column argues that the current structure of large EU banks is not conducive to an effective and unbiased resolution procedure. The authors would require systemically important banks to reorganise into a ‘holding company’ structure......, where the parent company holds unsecured term debt sufficient to cover losses at its operating financial subsidiaries. This would facilitate a ‘single point of entry’ resolution procedure, minimising the risk of creditor runs and destructive ring-fencing by national regulators....

  5. 基于PMMA毛细管电泳芯片的多位点突变检测研究%Multiplex Mutation Detection by PMMA Microhip-based Capillary Electrophoresis

    马辰; 张冠斌; 邓涛; 王怡瑞; 邢婉丽; 程京


    The technology of microchip-based capillary electrophoresis (MCE) is now widely used in analytical and life science researches. In this paper, we designed a microchip-based capillary electrophoresis platform using laser-induced fluorescence (LIF) detection method and polymethyl methacrylate(PMMA) chips manufactured by UV-LIGA technology. We evaluated the resolution gained by wall coating of a PMMA chip and optimized the electrophoresis conditions including the effective separation distance and the sieving matrix. By applying the optimized conditions, we achieved a single-base resolution of DNA fragments in only 90 seconds on this platform. In addition, we genotyped clinical samples containing three common mutation sites associated with hereditary hearing loss and demonstrated the potential application of the PMMA microchip-based capillary electrophoresis system in clinical diagnostic fields.%利用基于激光诱导荧光(LIF)检测的芯片毛细管电泳平台,批量制作了低成本聚甲基丙烯酸甲酯(PMMA)芯片,通过修饰管道,优化有效分离距离、分离介质等条件,可在90 s内完成DNA片段的分离检测,实现单碱基分离,并在此平台上成功地对遗传性耳聋三个常见突变位点实现分型检测,为这种低成本的PMMA芯片应用于分型相关的临床诊断领域奠定了基础.

  6. Combining high-throughput MALDI-TOF mass spectrometry and isoelectric focusing gel electrophoresis for virtual 2D gel-based proteomics.

    Lohnes, Karen; Quebbemann, Neil R; Liu, Kate; Kobzeff, Fred; Loo, Joseph A; Ogorzalek Loo, Rachel R


    The virtual two-dimensional gel electrophoresis/mass spectrometry (virtual 2D gel/MS) technology combines the premier, high-resolution capabilities of 2D gel electrophoresis with the sensitivity and high mass accuracy of mass spectrometry (MS). Intact proteins separated by isoelectric focusing (IEF) gel electrophoresis are imaged from immobilized pH gradient (IPG) polyacrylamide gels (the first dimension of classic 2D-PAGE) by matrix-assisted laser desorption/ionization (MALDI) MS. Obtaining accurate intact masses from sub-picomole-level proteins embedded in 2D-PAGE gels or in IPG strips is desirable to elucidate how the protein of one spot identified as protein 'A' on a 2D gel differs from the protein of another spot identified as the same protein, whenever tryptic peptide maps fail to resolve the issue. This task, however, has been extremely challenging. Virtual 2D gel/MS provides access to these intact masses. Modifications to our matrix deposition procedure improve the reliability with which IPG gels can be prepared; the new procedure is described. Development of this MALDI MS imaging (MSI) method for high-throughput MS with integrated 'top-down' MS to elucidate protein isoforms from complex biological samples is described and it is demonstrated that a 4-cm IPG gel segment can now be imaged in approximately 5min. Gel-wide chemical and enzymatic methods with further interrogation by MALDI MS/MS provide identifications, sequence-related information, and post-translational/transcriptional modification information. The MSI-based virtual 2D gel/MS platform may potentially link the benefits of 'top-down' and 'bottom-up' proteomics.

  7. Optimization of capillary array electrophoresis single-strand conformation polymorphism analysis for routine molecular diagnostics.

    Jespersgaard, Cathrine; Larsen, Lars Allan; Baba, Shingo; Kukita, Yoji; Tahira, Tomoko; Christiansen, Michael; Vuust, Jens; Hayashi, Kenshi; Andersen, Paal Skytt


    Mutation screening is widely used for molecular diagnostics of inherited disorders. Furthermore, it is anticipated that the present and future identification of genetic risk factors for complex disorders will increase the need for high-throughput mutation screening technologies. Capillary array electrophoresis (CAE) SSCP analysis is a low-cost, automated method with a high throughput and high reproducibility. Thus, the method fulfills many of the demands to be met for application in routine molecular diagnostics. However, the need for performing the electrophoresis at three temperatures between 18 degrees C and 35 degrees C for achievement of high sensitivity is a disadvantage of the method. Using a panel of 185 mutant samples, we have analyzed the effect of sample purification, sample medium and separation matrix on the sensitivity of CAE-SSCP analysis to optimize the method for molecular diagnostic use. We observed different effects from sample purification and sample medium at different electrophoresis temperatures, probably reflecting the complex interplay between sequence composition, electrophoresis conditions and sensitivity in SSCP analysis. The effect on assay sensitivity from three different polymers was tested using a single electrophoresis temperature of 27 degrees C. The data suggest that a sensitivity of 98-99% can be obtained using a 10% long chain poly-N,N-dimethylacrylamide polymer.

  8. Nonlinear effects on electrophoresis of a charged dielectric nanoparticle in a charged hydrogel medium

    Bhattacharyya, S.; De, Simanta


    The impact of the solid polarization of a charged dielectric particle in gel electrophoresis is studied without imposing a weak-field or a thin Debye length assumption. The electric polarization of a dielectric particle due to an external electric field creates a non-uniform surface charge density, which in turn creates a non-uniform Debye layer at the solid-gel interface. The solid polarization of the particle, the polarization of the double layer, and the electro-osmosis of mobile ions within the hydrogel medium create a nonlinear effect on the electrophoresis. We have incorporated those nonlinear effects by considering the electrokinetics governed by the Stokes-Brinkman-Nernst-Planck-Poisson equations. We have computed the governing nonlinear coupled set of equations numerically by adopting a finite volume based iterative algorithm. Our numerical method is tested for accuracy by comparing with several existing results on free-solution electrophoresis as well as results based on the Debye-Hückel approximation. Our computed result shows that the electrophoretic velocity decreases with the rise of the particle dielectric permittivity constant and attains a saturation limit at large values of permittivity. A significant impact of the solid polarization is found in gel electrophoresis compared to the free-solution electrophoresis.

  9. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis.

    Scherer, James R; Liu, Peng; Mathies, Richard A


    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ~20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex(®) 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  10. Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015.

    Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J


    An overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems reported in the literature between July 2013 and June 2015 is provided in this paper. The present article is a continuation of our previous review papers on this topic which covered the time period 2000-2013 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54; Electrophoresis 2012, 33, 243-250; Electrophoresis 2014, 35, 128-137). The use of in-line and on-line SPE-CE approaches is treated and outlined in this review. Recent advancements, such as, for example, the use of aptamers as affinity material for in-line SPE-CE, the use of a bead string design for in-line fritless SPE-CE, and new interfacing techniques for the on-line coupling of SPE to CE, are outlined. Selected examples demonstrate the applicability of the coupled SPE-CE systems for biomedical, pharmaceutical, environmental, and food studies. A complete overview of the recent SPE-CE studies is given in table format, providing information on sample type, SPE sorbent, coupling mode, detection mode, and LOD. Finally, some general conclusions and perspectives are provided.

  11. LHCb VELO Tracking Resolutions

    Alexander, Michael


    The excellent tracking performance of the Vertex Locator (VELO) at LHCb is presented. The resolutions it achieves on single hits, impact parameters, and primary vertex positions are shown, with particular attention paid to measurement of impact parameters.

  12. High Resolution Elevation Contours

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  13. Ultra high resolution tomography

    Haddad, W.S.


    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  14. Scalable Resolution Display Walls

    Leigh, Jason


    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  15. Development and validation of non-aqueous capillary electrophoresis methods to analyze boronic esters and acids.

    Forst, Mindy B; Warner, Anne M


    Boronic esters and acids are potential intermediates in the manufacture of many active pharmaceutical ingredients (API). Accurate quantitation of the intermediate is necessary to assure the stoichiometry of the reaction. The analysis of these compounds is challenging due to their labile nature. For example, the boronic ester can hydrolyze to the acid during storage, when exposed to moisture in the air, during sample preparation and analysis, and thus give erroneous ester results. Traditional analytical techniques like gas chromatography (GC), normal phase chromatography (NPLC), hydrophilic interaction chromatography (HILIC), and reversed phase liquid chromatography (RPLC) have been utilized but with noted limitations such as poor peak shape, variation in retention times, and evidence of hydrolysis. All of these limitations impact accurate quantitation needed for selected situations. For the proprietary boronic ester evaluated here, these traditional techniques were insufficient for the accurate determination of assay and residual boronic acid. Non-aqueous capillary electrophoresis (NACE) is an accurate quantitative technique that can be used to analyze boronic esters and their corresponding acids without the limitations noted for traditional analytical techniques. The present study describes the development of methodology for the determination of the potency of a proprietary boronic ester as well as methodology for the determination of residual boronic acid in the ester. In addition, nine model boronic ester and acid pairs with a range in polarity, based on the electronic properties of the attached side group, were tested to evaluate and demonstrate the general applicability of these conditions. Under the conditions used for potency, all ten pairs had a resolution between the boronic ester and acid of greater than 1.5, acceptable peak shape for the boronic ester (tailing factor of less than 2.0), and a run time of less than 3 min. In addition, this work describes

  16. Nonaqueous capillary electrophoresis of dextromethorphan and its metabolites.

    Pelcová, Marta; Langmajerová, Monika; Cvingráfová, Eliška; Juřica, Jan; Glatz, Zdeněk


    This study deals with the nonaqueous capillary electrophoretic separation of dextromethorphan and its metabolites using a methanolic background electrolyte. The optimization of separation conditions was performed in terms of the resolution of dextromethorphan and dextrorphan and the effect of separation temperature, voltage, and the characteristics of the background electrolyte were studied. Complete separation of all analytes was achieved in 40 mM ammonium acetate dissolved in methanol. Hydrodynamic injection was performed at 3 kPa for 4 s. The separation voltage was 20 kV accompanied by a low electric current. The ultraviolet detection was performed at 214 nm, the temperature of the capillary was 25°C. These conditions enabled the separation of four analytes plus the internal standard within 9 min. Further, the developed method was validated in terms of linearity, sensitivity, and repeatability. Rat liver perfusate samples were subjected to the nonaqueous capillary electrophoretic method to illustrate its applicability.

  17. Images of gel electrophoresis - RGP caps | LSDB Archive [Life Science Database Archive metadata

    Full Text Available [ Credits ] BLAST Search Image Search Home About Archive Update History Contact us RGP caps Images of gel... electrophoresis Data detail Data name Images of gel electrophoresis Description of da...ta contents Detailed information and images of gel electrophoresis of each marker. Data file File name: rgp_...mM KCl, and 0.001% (w/v) gelatin), and 40 mM MgCl 2 in 20.0 μL volume. Amplification was performed in GeneAm...d 72°C (2 min), and a final cycle of 72°C for 7 min. The amplified DNA products were electrophoresed on 3.0% agarose gel


    ZHU Xue-qiong; ZHU Chun-dan; L(U) Jie-qiang; DONG Ke


    Objective: To establish and optimize the two-demensional electrophoresis maps of uterine leiomyoma and to study the difference of global protein patterns between uterine leiomyoma and normal myometrium. Methods: Using Two-dimensional electrophoresis followed by computer-assisted image analysis, the differential proteins between uterine leiomyoma and normal myometrium were compared. Results: The well-resolved and reproducible two-dimensional gel electrophoresis patterns of uterine leiomyoma and normal myometrium were established. Totally 1085(108 and 1103(151 protein spots were obtained by using the pH 4-7 IPG strips in uterine leiomyoma and normal myometrium map, respectively, of which 7 spots increased and 15 spots decreased in quantity in uterine leiomyoma compared with normal myometrium. Conclusion: The differentially expressed proteins are useful for studying the mechanism of the cause of uterine leiomyoma.

  19. Capillary electrophoresis for the analysis of tropane alkaloids: pharmaceutical and phytochemical applications.

    Mateus, L; Cherkaoui, S; Christen, P; Veuthey, J L


    Three capillary electrophoresis methods, using UV detection, were developed for the simultaneous determination of several tropane alkaloids, including atropine, scopolamine and synthetic derivatives. After optimization, the validated capillary zone electrophoresis methods were applied to the determination of these compounds in various pharmaceutical forms, such as ophthalmic and injection solutions, tablets, suppositories and aerosols. Capillary electrophoresis in the micellar mode was found to be more appropriate for the analysis of hyoscyamine and scopolamine in plant material. These two compounds are generally found together with other tropane alkaloids which present similar structures and charge to mass ratio. Furthermore, the separation of positional isomers, such as hyoscyamine and littorine generally encountered in plant extracts, was also considered. The developed method was applied to the analysis of hairy root extracts of Datura candida x Datura aurea, Datura quercifolia and Hyoscyamus albus.

  20. Determination of preservatives in soft drinks by capillary electrophoresis with ionic liquids as the electrolyte additives.

    Sun, Bingbing; Qi, Li; Wang, Minglin


    A capillary electrophoresis method for separating preservatives with various ionic liquids as the electrolyte additives has been developed. The performances for separation of the preservatives using five ionic liquids with different anions and different substituted group numbers on imidazole ring were studied. After investigating the influence of the key parameters on the separation (the concentration of ionic liquids, pH, and the concentration of borax), it has been found that the separation efficiency could be improved obviously using the ionic liquids as the electrolyte additives and tested preservatives were baseline separated. The proposed capillary electrophoresis method exhibited favorable quantitative analysis property of the preservatives with good linearity (r(2) = 0.998), repeatability (relative standard deviations ≤ 3.3%) and high recovery (79.4-117.5%). Furthermore, this feasible and efficient capillary electrophoresis method was applied in detecting the preservatives in soft drinks, introducing a new way for assaying the preservatives in food products.