WorldWideScience

Sample records for resolution alpha spectrometry

  1. Determination of radium-226 by high-resolution alpha spectrometry

    International Nuclear Information System (INIS)

    Sill, C.W.

    1983-01-01

    The determination of radium-226 by alpha spectrometry has been investigated critically to determine experimental conditions under which high resolution and accurate and reliable results can be obtained. Refractory solids such as soils, ores, and tailings from uranium mills are dissolved completely by fusion with potassium fluoride in the presence of barium-133 tracer. The fluoride cake is then transposed with sulfuric acid to a pyrosulfate fusion with simultaneous volatilization of all silica and fluoride. Radium is precipitated with barium already present in the sample by addition of lead perchlorate to a dilute hydrochloric acid solution of the pyrosulfate cake. The resulting insoluble sulfates are dissolved in an alkaline solution of diethylenetriaminepentaacetic acid, and the radium and barium sulfates are reprecipitated with acetic acid. The precipitate is mounted on a membrane filter and analyzed by alpha spectrometry. Water samples are partially evaporated and treated similarly. Resolution of the subsequent alpha spectra is much better than has been achieved previously from barium sulfate, and is almost as good as is obtainable with actinides electrodeposited on polished steel plates. The resolution is about 60 keV full-width-half-maximum with 100 μg of barium on a 1-inch filter with a 450 mm 2 detector at 20% counting efficiency. Recovery is about 97% and accuracy is generally as good as the counting statistics obtained will permit. Grossly inaccurate results can be obtained under certain conditions when barium-133 tracer is used to determine the chemical yield of radium-226. Severe contamination of the surface-barrier detector by polonium-210 and by recoil products of the radium isotopes being counted is demonstrated, amd methods for virtual elimination of both problems are discussed

  2. Determination of radium-226 by high-resolution alpha spectrometry

    International Nuclear Information System (INIS)

    Sill, C.W.

    1983-01-01

    Condition were determined under which high resolution and accurate and reliable results can be obtained. Refractory solids are dissolved completely by fusion with KF and Ba-133 tracer. The fluoride cake is then transposed with sulfuric acid to a pyrosulfate fusion. Radium is precipitated with barium by addition of lead perchlorate to a dilute HCl solution of the pyrosulfate cake. The resulting insoluble sulfates are dissolved in an alkaline solution of DTPA and the Ra and Ba sulfates are reprecipitated with acetic acid to produce very small crystals. The precipitate is mounted on 0.1-μm membrane filter and analyzed by alpha spectrometry. Water samples are partially evaporated and treated similarly. Resolution, almost as good as with actinides electrodeposited on polished steel plates, is about 60 keV full-width-half-maximum with 100 μg of barium on a 1-inch filter with a 450 mm 2 detector at 20% counting efficiency. Recovery is about 97%. One solid sample can be prepared for counting in less than 2 hours. Methods are discussed for ensuring reliability of the results. Severe contamination of the surface-barrier detector by polonium-210 and recoil products is discussed

  3. Use of Peltier cells in high resolution alpha spectrometry

    International Nuclear Information System (INIS)

    Bueno, C.C.; Santos, M.D.S.; Goncalves, J.A.C.

    1994-01-01

    The experiments with low-cost commercial silicon PIN photodiodes have shown the possibility of their transformation for use as alpha detectors with performance comparable with surface barrier detectors which are more expensive. Utilizing the silicon photodiode with reverse bias, an energy resolution for 241 Am alpha particles of 28 KeV and 23 KeV were obtained at room temperature and at -30 0 C respectively. (author). 4 refs, 4 figs

  4. Determination of 239Pu/240Pu isotopic ratio by high resolution alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Amoudry, F.; Burger, P.

    1983-05-01

    The development of passivated ion-implanted silicon detectors and of very thin alpha-particle sources improves the resolution of alpha-particle spectra and allows to separate energy pics up to now unseparate. The 239 Pu/ 240 Pu isotopic ratio of a mixture has been measured using the alpha spectrometry deconvolution code DEMO [fr

  5. Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

    International Nuclear Information System (INIS)

    Bacrania, Minesh K.; Croce, Mark; Bond, Evelyn; Dry, Donald; Moody, W. Allen; Lamont, Stephen; Rabin, Michael; Rim, Jung; Smith, Audrey; Beall, James; Bennett, Douglas; Kotsubo, Vincent; Horansky, Robert; Hilton, Gene; Schmidt, Daniel; Ullom, Joel; Cantor, Robin

    2010-01-01

    We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

  6. Simulation study for high resolution alpha particle spectrometry with mesh type collimator

    International Nuclear Information System (INIS)

    Park, Seunghoon; Kwak, Sungwoo; Kang, Hanbyeol; Shin, Jungki; Park, Iljin

    2014-01-01

    An alpha particle spectrometry with a mesh type collimator plays a crucial role in identifying specific radionuclide in a radioactive source collected from the atmosphere or environment. The energy resolution is degraded without collimation because particles with a high angle have a longer path to travel in the air. Therefore, collision with the background increases. The collimator can cut out particles which traveling at a high angle. As a result, an energy distribution with high resolution can be obtained. Therefore, the mesh type collimator is simulated for high resolution alpha particle spectrometry. In conclusion, the collimator can improve resolution. With collimator, the collimator is a role of cutting out particles with a high angle, so, low energy tail and broadened energy distribution can be reduced. The mesh diameter is found out as an important factor to control resolution and counting efficiency. Therefore, a target particle, for example, 235 U, can be distinguished by a detector with a collimator under a mixture of various nuclides, for example: 232 U, 238 U, and 232 Th

  7. Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Rabin, Michael W.; Hoover, Andrew S.; Bacrania, Minesh K.; Croce, Mark P.; Hoteling, N.J.; Lamont, S.P.; Plionis, A.A.; Dry, D.E.; Ullom, J.N.; Bennett, D.A.; Horansky, R.; Kotsubo, V.; Cantor, R.

    2009-01-01

    Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with ∼15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

  8. Cryogenic Microcalorimeter System for Ultra-High Resolution Alpha-Particle Spectrometry

    Science.gov (United States)

    Croce, M. P.; Bacrania, M. K.; Hoover, A. S.; Rabin, M. W.; Hoteling, N. J.; LaMont, S. P.; Plionis, A. A.; Dry, D. E.; Ullom, J. N.; Bennett, D. A.; Horansky, R. D.; Kotsubo, V.; Cantor, R.

    2009-12-01

    Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with ˜15-μK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis. This paper will discuss design and operation of our microcalorimeter alpha-particle spectrometer, and will show recent results.

  9. Factors affecting the energy resolution in alpha particle spectrometry with silicon diodes

    International Nuclear Information System (INIS)

    Camargo, Fabio de.

    2005-01-01

    In this work are presented the studies about the response of a multi-structure guard rings silicon diode for detection and spectrometry of alpha particles. This ion-implanted diode (Al/p + /n/n + /Al) was processed out of 300 μm thick, n type substrate with a resistivity of 3 kΩ·cm and an active area of 4 mm 2 . In order to use this diode as a detector, the bias voltage was applied on the n + side, the first guard ring was grounded and the electrical signals were readout from the p + side. These signals were directly sent to a tailor made preamplifier, based on the hybrid circuit A250 (Amptek), followed by a conventional nuclear electronic. The results obtained with this system for the direct detection of alpha particles from 241 Am showed an excellent response stability with a high detection efficiency (≅ 100 %). The performance of this diode for alpha particle spectrometry was studied and it was prioritized the influence of the polarization voltage, the electronic noise, the temperature and the source-diode distance on the energy resolution. The results showed that the major contribution for the deterioration of this parameter is due to the diode dead layer thickness (1 μm). However, even at room temperature, the energy resolution (FWHM = 18.8 keV) measured for the 5485.6 MeV alpha particles ( 241 Am) is comparable to those obtained with ordinary silicon barrier detectors frequently used for these particles spectrometry. (author)

  10. Alpha spectrometry without chemistry

    International Nuclear Information System (INIS)

    Murray, A.S.; Heaton, B.

    1983-01-01

    A gridded cylindrical pulse ionization chamber is considered for the simultaneous analysis of natural alpha emitters. Solid sources of up to 0.3 g are deposited after wet grinding as a thin layer on 1.1 m 2 of aluminized plastic film, which acts as the cathode. No chemistry is involved, and thus there is little chance of nuclide fractionation. With a ''weightless'' source the resolution is about 55 keV; 110 keV has been easily achieved at 4.2 MeV with real sources. We conclude that significant information about isotope activities in the natural series is available with only a fraction of the work involved in conventional techniques. (author)

  11. Factors affecting the energy resolution in alpha particle spectrometry with silicon diodes; Fatores que influenciam a resolucao em energia na espectrometria de particulas alfa com diodos de Si

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Fabio de. E-mail: f.camargo@bol.com.br

    2005-07-01

    In this work are presented the studies about the response of a multi-structure guard rings silicon diode for detection and spectrometry of alpha particles. This ion-implanted diode (Al/p{sup +}/n/n{sup +}/Al) was processed out of 300 {mu}m thick, n type substrate with a resistivity of 3 k{omega}{center_dot}cm and an active area of 4 mm{sup 2}. In order to use this diode as a detector, the bias voltage was applied on the n{sup +} side, the first guard ring was grounded and the electrical signals were readout from the p{sup +} side. These signals were directly sent to a tailor made preamplifier, based on the hybrid circuit A250 (Amptek), followed by a conventional nuclear electronic. The results obtained with this system for the direct detection of alpha particles from {sup 241}Am showed an excellent response stability with a high detection efficiency ({approx_equal} 100 %). The performance of this diode for alpha particle spectrometry was studied and it was prioritized the influence of the polarization voltage, the electronic noise, the temperature and the source-diode distance on the energy resolution. The results showed that the major contribution for the deterioration of this parameter is due to the diode dead layer thickness (1 {mu}m). However, even at room temperature, the energy resolution (FWHM = 18.8 keV) measured for the 5485.6 MeV alpha particles ({sup 241}Am) is comparable to those obtained with ordinary silicon barrier detectors frequently used for these particles spectrometry. (author)

  12. Low Cost silicon photodiodes for alpha spectrometry

    International Nuclear Information System (INIS)

    Khoury, H.; Lopes, A.; Hazin, C.; Lira, C.B.; Silva, E. da

    1998-01-01

    This study was carried out to evaluate the suitability of using commercially available photodiodes for alpha spectrometry, since the principle on which both operate are similar. Photodiodes are low priced compared to the commonly used semiconductor detectors making them potentially useful for research and teaching purposes. Very thin calibrated alpha sources of 2 41 A m, 2 44 C m and 2 35 U , produced at the Metrology Laboratory of IRD/CNEN, were used to test the performance of three photodiodes. The results showed that the responses of the photodiodes were linear with the alpha particle energy and that the energy resolution varied between 0,79% and 0,45%, with an efficiency of 8%. The resolution and efficiency presented by the photodiodes tested are similar to those obtained with other semiconductor detectors, evidencing that they can be used successfully as alpha detectors

  13. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  14. Set-up of an alpha-spectrometry system

    International Nuclear Information System (INIS)

    Calicchia, A.

    1976-01-01

    Principle of operation of alpha-spectrometry system is described, using a solid state detector, which allows to precisely determine sample's activity and specify alpha-emitting radionuclides. Measurements which allow to define system performances are shown, that is energy resolution and real sensitivity of spectrometer

  15. Performance Test of Alpha Spectrometry for Environmental Radioactivity Analysis

    International Nuclear Information System (INIS)

    Choi, Jung Youn; Yoon, Jong-Ho; Han, Ki-Tek; Ahn, Gil Hoon

    2015-01-01

    Environmental samples are analyzed by various methods such as, ICP-MS (inductively coupled plasma mass spectrometry), AMS (accelerator mass spectrometry) TIMS (thermal ionization mass spectrometry), HRGS (high resolution gamma spectrometry) and alpha /beta particle analysis. In this study, we will described the result of performance test using alpha spectrometry for analyzing environmental samples. Measurement data of the U activity using SRM based on extraction chromatography with UTEVA resin. It should be effective way to separate of uranium isotope for the measurement of alpha spectrometry. But, the result of this measurement data is higher than another recovery data. Also concentration of U data is lack of consistency. We leave out of consideration many effect of factors about influence in the experiment process. In the future work, we will try to reduce the step of experiment process and reflect the uncertainty factors

  16. Alpha and beta detection and spectrometry

    International Nuclear Information System (INIS)

    Saro, S.

    1984-01-01

    The theory of alpha and beta radioactive decay, the interaction of alpha and beta particles with matter, and their detection and spectrometry are dealt with in seven chapters: 1. Alpha transformation of atomic nuclei; 2. Basic properties of detectors and statistics of detection; 3. Alpha detectors and spectrometers; 4. Applications of alpha detection and spectrometry; 5. Beta transformation of atomic nuclei; 6. Beta particle detectors and spectrometers; 7. Detection of low energy beta particles. Chapter 8 is devoted to sampling and preparation of samples for radiometry. (E.F.)

  17. Alpha spectrometry and secondary ion mass spectrometry of thorium

    International Nuclear Information System (INIS)

    Strisovska, Jana; Kuruc, Jozef; Galanda, Dusan; Matel, Lubomir; Velic, Dusan; Aranyosiova, Monika

    2009-01-01

    A sample of thorium content on steel discs was prepared by electrodeposition with a view to determining the natural thorium isotope. Thorium was determined by alpha spectrometry and by secondary ion mass spectrometry and the results of the two methods were compared

  18. Test chamber for alpha spectrometry

    Science.gov (United States)

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  19. Source preparation in alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lally, A E [UKAEA Atomic Energy Research Establishment, Harwell. Environmental and Medical Sciences Div.; Glover, K M [UKAEA Atomic Energy Research Establishment, Harwell. Chemistry Div.

    1984-06-15

    Techniques, for the preparation of sources suitable for alpha spectrometric measurements are presented. These include vacuum sublimation, electrodeposition, self-deposition, direct evaporation, direct precipitation and the use of solvents and spreading agents. The relative merits of each technique and the applicability to both high and low levels of activity are considered.

  20. Determination of plutonium-238 in plutonium by alpha spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jain, H.C.; Mathews, C.K.; Ramaniah, M.V.

    1975-01-01

    A method is presented for the determination of 238 Pu in plutonium samples by alpha spectrometry. Various factors attributing towards the energy degradation, a problem usually encountered in alpha spectrometry, are discussed. A computer programme is given for the evaluation of peak areas when the alpha spectrum is degraded. The results are compared with those obtained by mass spectrometry. (author)

  1. Liquid scintillation alpha particle spectrometry. Progress report

    International Nuclear Information System (INIS)

    Bell, L.L.; Hakooz, S.A.; Johnson, L.O.; Nieschmidt, E.B.; Meikrantz, D.H.

    1979-12-01

    Objective to develop a technique whereby Pu may be put into solution, extracted by solvent extraction into a suitable extractive scintillant and subsequently counted. Presented here are results of attempts to separate beta and alpha activities through pulse shape discrimination. A qualitative discussion is given which yields alpha particle peak widths, resolution and response. The detection efficiency for alpha particles in a liquid scintillant is 100%. Present detection sensitivities of the equipment being used are: 4.5 x 10 -6 μCi (100 s), 1.2 x 10 -6 μCi (1000 s), and 4.0 x 10 -7 μCi (10,000 s) at the 3 sigma level. The detectability of a particular alpha-emitting species is strongly dependent upon the population of other species. The ability to discriminate depends upon the system resolution. 14 figures, 2 tables

  2. New advanced in alpha spectrometry by liquid scintillation methods

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1979-01-01

    Although the ability to count alpha particles by liquid scintillation methods has been long recognized, limited use has been made of the method because of problems of high background and alpha energy identification. In recent years some new developments in methods of introducing the alpha-emitting nuclide to the scintillator, in detector construction, and in electronics for processing the energy analog and time analog signals from the detector have allowed significant alleviation of the problems of alpha spectrometry by liquid scintillation. Energy resolutions of 200 to 300 keV full peak width at half maximum and background counts of 99% of all beta plus gamma interference is now possible. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are available for a variety of analyses

  3. Monte Carlo simulation applied to alpha spectrometry

    International Nuclear Information System (INIS)

    Baccouche, S.; Gharbi, F.; Trabelsi, A.

    2007-01-01

    Alpha particle spectrometry is a widely-used analytical method, in particular when we deal with pure alpha emitting radionuclides. Monte Carlo simulation is an adequate tool to investigate the influence of various phenomena on this analytical method. We performed an investigation of those phenomena using the simulation code GEANT of CERN. The results concerning the geometrical detection efficiency in different measurement geometries agree with analytical calculations. This work confirms that Monte Carlo simulation of solid angle of detection is a very useful tool to determine with very good accuracy the detection efficiency.

  4. Alpha spectrometry and the secondary ion mass spectrometry of thorium

    International Nuclear Information System (INIS)

    Strisovska, J.; Kuruc, J.; Galanda, D.; Matel, L.; Aranyosiova, M.; Velic, D.

    2009-01-01

    The main objective of this master thesis was preparation of samples with thorium content on the steel discs by electrodeposition for determination of natural thorium isotope by alpha spectrometry and the secondary ion mass spectrometry and finding out their possible linear correlation between these methods. The samples with electrolytically excluded isotope of 232 Th were prepared by electrodeposition from solution Th(NO 3 ) 4 ·12 H2 O on steel discs in electrodeposition cell with use of solutions Na 2 SO 4 , NaHSO 4 , KOH and (NH 4 ) 2 (C 2 O 4 ) by electric current 0.75 A. Discs were measured by alpha spectrometer. Activity was calculated from the registered impulses for 232 Th and surface's weight. After alpha spectrometry measurements discs were analyzed by TOF-SIMS IV which is installed in the International Laser Centre in Bratislava. Intensities of isotope of 232 Th and ions of ThO + , ThOH + , ThO 2 H + , Th 2 O 4 H + , ThO 2 - , ThO 3 H - , ThH 3 O 3 - and ThN 2 O 5 H - were identified. The linear correlation is between surface's weights of Th and intensities of ions of Th + from SIMS, however the correlation coefficient has relatively low value. We found out with SIMS method that oxidized and hydride forms of thorium are significantly represented in samples with electroplated thorium. (authors)

  5. Alpha particle analysis using PEARLS spectrometry

    International Nuclear Information System (INIS)

    McKlveen, J.W.; Klingler, G.W.; McDowell, W.J.; Case, G.N.

    1984-01-01

    Alpha particle assay by conventional plate-counting methods is difficult because chemical separation, tracer techniques, and/or self-absorption losses in the final sample may cause either non-reproducible results or create unacceptable errors. PEARLS (Photon-Electron Rejecting Alpha Liquid Scintillation) Spectrometry is an attractive alternative since radionuclides may be extracted into a scintillator in which there would be no self-absorption or geometry problems and in which up to 100% chemical recovery and counting efficiency is possible. Sample preparation may include extraction of the alpha emitter of interest by a specific organic-phase-soluble compound directly into the liquid scintillator. Detection electronics use energy and pulse-shape discrimination to provide discrete alpha spectra and virtual absence of beta and gamma backgrounds. Backgrounds on the order of 0.01 cpm are readily achievable. Accuracy and reproducibility are typically in the 100 +-1% range. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium, and polonium assay. This paper will review liquid scintillation alpha counting methods and reference some of the specific applications. 8 refs., 1 fig

  6. Alpha-particle emission probabilities of ²³⁶U obtained by alpha spectrometry.

    Science.gov (United States)

    Marouli, M; Pommé, S; Jobbágy, V; Van Ammel, R; Paepen, J; Stroh, H; Benedik, L

    2014-05-01

    High-resolution alpha-particle spectrometry was performed with an ion-implanted silicon detector in vacuum on a homogeneously electrodeposited (236)U source. The source was measured at different solid angles subtended by the detector, varying between 0.8% and 2.4% of 4π sr, to assess the influence of coincidental detection of alpha-particles and conversion electrons on the measured alpha-particle emission probabilities. Additional measurements were performed using a bending magnet to eliminate conversion electrons, the results of which coincide with normal measurements extrapolated to an infinitely small solid angle. The measured alpha emission probabilities for the three main peaks - 74.20 (5)%, 25.68 (5)% and 0.123 (5)%, respectively - are consistent with literature data, but their precision has been improved by at least one order of magnitude in this work. © 2013 Published by Elsevier Ltd.

  7. Intercomparison of alpha particle spectrometry software packages

    International Nuclear Information System (INIS)

    1999-08-01

    Software has reached an important level as the 'logical controller' at different levels, from a single instrument to an entire computer-controlled experiment. This is also the case for software packages in nuclear instruments and experiments. In particular, because of the range of applications of alpha-particle spectrometry, software packages in this field are often used. It is the aim of this intercomparison to test and describe the abilities of four such software packages. The main objectives of the intercomparison were the ability of the programs to determine the peak areas and the peak area uncertainties, and the statistical control and stability of reported results. In this report, the task, methods and results of the intercomparison are presented in order to asist the potential users of such software and to stimulate the development of even better alpha-particle spectrum analysis software

  8. Response of commercial photodiodes for application in alpha spectrometry

    International Nuclear Information System (INIS)

    Ferreira Filho, Alfredo Lopes

    1998-06-01

    The use of semiconductor detector for ionizing radiations spectrometry and dosimetry has been growing in the last years due to its characteristics of fast response, good efficiency for unit of volume and excellent resolution. Since the working principle of a semiconductor detector is identical to that of the semiconductor junctions of commercial electronic devices, a study was carried out on the PIN-photodiodes response, aiming at set up an alpha spectrometry system of low cost and easy acquisition. The tested components have the following characteristics: active area varying between 13.2 and 25 mm 2 , window of thickness equal or lower than 57 mg/cm 2 , depletion area with depth ranging from 10 to 300 μm and junction capacitance of 16 to 20 pF.Am-241, Cm-244, U-233 and Np-237 alpha sources produced by electrodeposition were used to evaluate the response of the devices as a function of the radiation energy. The results have shown a linear response of the photodiodes with the incident alpha particle energy. The resolution varied from 1.6% to 0.45% and the better detection efficiency found was about 7.2. The low cost of the photodiodes and the excellent results obtained at room temperature make such components very attractive for teaching purposes for environmental monitoring. (author)

  9. Problems and progress in the preparation of sources for the alpha spectrometry of plutonium

    International Nuclear Information System (INIS)

    Miguel, M.; Deron, S.; Swietly, H.; Heinonen, O.J.

    1981-01-01

    The interpretation of non-destructive measurements of plutonium materials require more accurate determinations of the isotopic abundance of Pu-238 than conventional chemical assays. The requirements of calorimetry, passive neutron and conventional chemical assays are presented and compared. When Pu-238 is measured by alpha spectrometry, these requirements define how well the plutonium must be separated from americium, and what should be the accuracy of the spectrometry. The latter can strongly depend upon the resolution of the alpha spectrum. The authors describe a procedure to produce sources by drop deposition which ensure a resolution of 17 keV with commercial instrumentation

  10. Micro-electrodeposition techniques for the preparation of small actinide counting sources for ultra-high resolution alpha spectrometry by microcalorimetry

    International Nuclear Information System (INIS)

    Plionis, A.A.; Hastings, E.P.; LaMont, S.P.; Dry, D.E.; Bacrania, M.K.; Rabin, M.W.; Rim, J.H.

    2009-01-01

    Special considerations and techniques are desired for the preparation of small actinide counting sources. Counting sources have been prepared on metal disk substrates (planchets) with an active area of only 0.079 mm 2 . This represents a 93.75% reduction in deposition area from standard electrodeposition methods. The actinide distribution upon the smaller planchet must remain thin and uniform to allow alpha particle emissions to escape the counting source with a minimal amount of self-attenuation. This work describes the development of micro-electrodeposition methods and optimization of the technique with respect to deposition time and current density for various planchet sizes. (author)

  11. High resolution spectrometry for relativistic heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Gabor, G; Schimmerling, W; Greiner, D; Bieser, F; Lindstrom, P [California Univ., Berkeley (USA). Lawrence Berkeley Lab.

    1975-12-01

    Several techniques are discussed for velocity and energy spectrometry of relativistic heavy ions with good resolution. A foil telescope with chevron channel plate detectors is described. A test of this telescope was performed using 2.1 GeV/A C/sup 6 +/ ions, and a time-of-flight resolution of 160 ps was measured. Qualitative information on the effect of foil thickness was also obtained.

  12. Determination of 226Ra by alpha spectrometry of liquid scintillation

    International Nuclear Information System (INIS)

    Nobrega, A.W.; Sachett, I.A.; Hespanhol, E.C.B.

    1987-01-01

    The determination of 226 Ra in environmental samples using alpha spectrometry in liquid scintilation is studied. The Radon 1-2 emanation method and 226 Ra separation process of other radionuclides alpha emissors are analyzed. The use of 226 Ra coprecipitation with barium sulphate is evaluated. (M.J.C.) [pt

  13. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  14. The combined measurement of uranium by alpha spectrometry and secondary ion mass spectrometry (SIMS)

    International Nuclear Information System (INIS)

    Harvan, D.

    2009-01-01

    The aim of thesis was to found the dependence between radiometric method - alpha spectrometry and surface sensitive method - Secondary Ion Mass Spectrometry (SIMS). Uranium or naturally occurring uranium isotopes were studied. Samples (high polished stainless steel discs) with uranium isotopes were prepared by electrodeposition. Samples were measured by alpha spectrometry after electrodeposition and treatment. It gives surface activities. Weights, as well as surface's weights of uranium isotopes were calculated from their activities, After alpha spectrometry samples were analyzed by TOF-SIMS IV instrument in International Laser Centre in Bratislava. By the SIMS analysis intensities of uranium-238 were obtained. The interpretation of SIMS intensities vs. surface activity, or surface's weights of uranium isotopes indicates the possibility to use SIMS in quantitative analysis of surface contamination by uranium isotopes, especially 238 U. (author)

  15. 226Ra determination in phosphogypsum by alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Aguado, J.L.; Bolivar, J.P.; Garcia-Tenorio, R.

    1999-01-01

    A radiochemical method for 226 Ra determination by alpha-particle spectrometry in environmental samples has been developed in our laboratory. The method has been validated by measurements in samples with known concentrations of this radionuclide and it has been applied in studies related to 226 Ra behaviour in phosphogypsum (the main by-product of producing phosphoric acid from phosphate rocks). (author)

  16. Depth resolution of secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Pustovit, A.N.

    2004-01-01

    The effect of the solid body discreteness in the direction of the normal to the sample surface on the depth resolution of the secondary ion mass spectrometry method is analyzed. It is shown that for this case the dependence of the width at the semi-height of the delta profiles of the studied elements depth distribution on the energy and angle of incidence of the initial ions should have the form of the stepwise function. This is experimentally proved by the silicon-germanium delta-layers in the silicon samples [ru

  17. Laboratory of High resolution gamma spectrometry

    International Nuclear Information System (INIS)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B.

    1992-01-01

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  18. Simultaneous determination of U and Pu isotopes by alpha spectrometry

    International Nuclear Information System (INIS)

    Equillor, H.E.; Campos, J.M.

    2011-01-01

    Determination of actinides by alpha spectrometry is usually carried out after full separation of each of the components of the sample. The procedure presented in this paper permits U and Pu isotopes to be measured together allowing faster sample processing and measurement. The method consists in the extraction with tributyl phosphate of U and Pu isotopes from the rest of the matrix, followed by a cathodic electrodeposition to obtain alpha spectrometry suitable pieces. It can be applied to various environmental samples, such as water, filters and soil (about 0.5 g of solid sample for the described conditions). High-quality electroplated discs are essential for simultaneous processing, so a technique to achieve this requirement is also explained. (authors) [es

  19. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  20. Development of gas ionization chambers with coplanar electrodes for alpha-ray spectrometry

    International Nuclear Information System (INIS)

    Iwasaki, Kenta; Tanaka, Naomichi; Murakami, Kohei; Hasebe, Nobuyuki; Kusano, Hiroki; Shibamura, Eido; Miyajima, Mitsuhiro

    2016-01-01

    A large-area alpha-ray spectrometer is required to measure the low level alpha emitters in environmental samples, which may be distributed in the vicinity of nuclear power plants. A gas ionization chamber with a coplanar electrode has attractive features such as with mechanical ruggedness, easy handling, easy fabrication of large electrode, and relatively well-known performance. We have investigated the performance of a gas ionization chamber with a coplanar electrode for alpha-ray spectrometry, particularly in the energy resolution. The present experiment shows that the energy resolution in the full width at half maximum (FWHM) is 129 keV (= 2.7%) for alpha-rays from Np with an energy of 4.78 MeV, 120 keV (= 2.2%) for those with 5.49 MeV from Am, and 109 keV (= 1.9%) for those with 5.81 MeV from Cm. It is found that the energy resolution obtained at the present experiment is dominated in the electronic noise caused by the large capacitance existed between the collecting anode (CA) and non-collecting anode (NCA) in the coplanar electrode. (author)

  1. Iterative inversion of gamma or alpha spectrometry data

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1985-12-01

    Gamma - and alpha ray spectrometry data are processed by an iterative regression method (Wolberg, 1967) to obtain the activities or yields of radionuclides. This method, applied to Nuclear Geophysics Research, permits the use of either selected energy bands or of all the channels one by one. It may be easily programmed in popular microcomputers and offers many advantages such as the use of mixtures of radionuclides for the calibrations and the treatment of the uncertainties on the measurements and results. Several conclusions about the method and options of nuclear data processing are presented. (Author) [pt

  2. Validation of Plutonium Radioisotopes Analysis Using Alpha Spectrometry

    International Nuclear Information System (INIS)

    Noor Fadzilah Yusof; Jalal Sharib; Mohd Tarmizi Ishak; Zulkifli Daud; Abdul Kadir Ishak

    2016-01-01

    This paper presents the validation of an established method used to detect plutonium (Pu) radioisotopes in marine environment samples. The separation method consists of sample digestion, anion exchange, purification, electroplating and counting by an alpha spectrometry. Applying the method on standard reference materials from marine environment, the results are validated using seven parameters, namely specificity, linearity, bias or accuracy, detection limit, precision/ repeatability, reproducibility/ ruggedness and robustness in accordance with International Organization for Standardization (ISO) guidelines. The findings were that the results obtained were in a good agreement and satisfactory compared to the provided readings from certificate of reference materials. (author)

  3. Chemical vapor deposition (CVD) of uranium for alpha spectrometry

    International Nuclear Information System (INIS)

    Ramirez V, M. L.; Rios M, C.; Ramirez O, J.; Davila R, J. I.; Mireles G, F.

    2015-09-01

    The uranium determination through radiometric techniques as alpha spectrometry requires for its proper analysis, preparation methods of the source to analyze and procedures for the deposit of this on a surface or substrate. Given the characteristics of alpha particles (small penetration distance and great loss of energy during their journey or its interaction with the matter), is important to ensure that the prepared sources are thin, to avoid problems of self-absorption. The routine methods used for this are the cathodic electro deposition and the direct evaporation, among others. In this paper the use of technique of chemical vapor deposition (CVD) for the preparation of uranium sources is investigated; because by this, is possible to obtain thin films (much thinner than those resulting from electro deposition or evaporation) on a substrate and comprises reacting a precursor with a gas, which in turn serves as a carrier of the reaction products to achieve deposition. Preliminary results of the chemical vapor deposition of uranium are presented, synthesizing and using as precursor molecule the uranyl acetylacetonate, using oxygen as carrier gas for the deposition reaction on a glass substrate. The uranium films obtained were found suitable for alpha spectrometry. The variables taken into account were the precursor sublimation temperatures and deposition temperature, the reaction time and the type and flow of carrier gas. Of the investigated conditions, two depositions with encouraging results that can serve as reference for further work to improve the technique presented here were selected. Alpha spectra obtained for these depositions and the characterization of the representative samples by scanning electron microscopy and X-ray diffraction are also presented. (Author)

  4. Liquid chromatography-high resolution mass spectrometry with immunoaffinity clean-up for the determination of the oxidative stress biomarker 8-iso-prostaglandin F2alpha in wastewater.

    Science.gov (United States)

    Ryu, Yeonsuk; Reid, Malcolm J; Thomas, Kevin V

    2015-08-28

    A reliable oxidative stress biomarker, 8-iso-prostaglandin F2α (8-iso-PGF2α), was for the first time quantitatively analysed in wastewater using an analytical method consisting of liquid chromatography-high resolution mass spectrometry coupled to immunoaffinity clean-up (IAC-LC-HRMS). Factors influencing the method's robustness were investigated, including analyte stability in sewage and enzymatic deconjugation with β-glucuronidase. The IAC-LC-HRMS method was linear over the range of 0.1-100ng/mL with correlation coefficient (R(2)) of 0.999. The quantification limits were sufficiently low to detect 8-iso-PGF2α in sewage (method quantification limit of 0.3ng/L) and precision, expressed as relative standard deviation was less than 7% and the accuracy expressed as relative recovery was in the 103-113% range. As a result, the application of the method to 24-h composite wastewater samples from Oslo showed 8-iso-PGF2α concentrations of 18.9-23.3ng/L for 8 days in March 2015. This study demonstrates a standard method to analyse 8-iso-PGF2α in sewage that will contribute to the further investigation of the potential use of 8-iso-PGF2α as a sewage biomarker for assessing the status of community health. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Determination of plutonium isotopes in bilberry using liquid scintillation spectrometry and alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Seferinoğlu, Meryem; Aslan, Nazife; Kurt, Aylin; Erden, Pınar Esra; Mert, Hülya

    2014-01-01

    This paper presents α-particle spectrometry and liquid scintillation spectrometry methods to determine plutonium isotopes in bilberry. The analytical procedure involves sample preparation steps for ashing, digestion of bilberry samples, radiochemical separation of plutonium radioisotopes and their measurement. The validity of the method was checked for coherence using the ζ test, z-test, relative bias and relative uncertainty outlier tests. The results indicated that the recommended procedures for both measurement systems could be successfully applied for the accurate determination of plutonium activities in bilberry samples. - Highlights: • Sample preparation methods for Pu using LSS and alpha spectrometry developed. • Complete separation of plutonium from interfering radionuclides. • Commercial bilberry was spiked with NPL 2011 (AH-B11144) proficiency test sample. • Results were checked using ζ test, z-test, rel. bias and rel. uncert. outlier tests. • Recommended procedures successfully applied to bilberry samples

  6. Analysis by {alpha} spectrometry (chamber with a grid). Proserpine (1960); Analyses par spectrometrie {alpha} (chambre a grille). Proserpine (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Clouet d' Orval, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The aim is to compare various substances in an electrolytic deposit by means of their {alpha} radiation. The energies are separated by counting in a chamber with a grid, specially designed for the analysis of plutonium. A resolution of 1.7 per cent is normally obtained for plutonium bands. {sup 239}Pu-{sup 233}Pu, {sup 239}Pu-{sup 238}Pu mixtures have been analysed by this method. (author) [French] Il s'agit de comparer, au moyen de leur rayonnement {alpha}, divers corps contenus dans un depot electrolytique. On separe les energies par comptage dans une chambre a grille, specialement concue pour analyser du plutonium. On obtient couramment une resolution de 1,7 pour cent, pour des raies du plutonium. On a pu faire, par cette methode, l'analyse de melanges {sup 239}Pu-{sup 233}Pu et {sup 239}Pu-{sup 238}Pu. (auteur)

  7. Performance of alpha spectrometry in the analysis of uranium isotopes in environmental and nuclear materials

    International Nuclear Information System (INIS)

    Carvalho, F.P.; Oliveira, J.M.

    2009-01-01

    The accuracy of alpha spectrometry in the determination of uranium isotopes at various concentrations levels and with various isotope ratios was tested in a round robin international intercomparison exercise. Results of isotope activity/mass and isotope mass ratios obtained by alpha spectrometry were accurate in a wide range of uranium masses and in isotopic ratios typical of depleted, natural, and low enriched uranium samples. Determinations by alpha spectrometry compared very satisfactorily in accuracy with those by mass spectrometry. For example, determination of U isotopes in natural uranium by alpha spectrometry agreed with mass spectrometry determinations at within ±1%. However, the 236 U isotope, particularly if present in activities much lower than 235 U, might not be determined accurately due to overlap in the alpha particle energies of these two uranium isotopes. (author)

  8. An open-flow pulse ionization chamber for alpha spectrometry of large-area samples

    International Nuclear Information System (INIS)

    Johansson, L.; Roos, B.; Samuelsson, C.

    1992-01-01

    The presented open-flow pulse ionization chamber was developed to make alpha spectrometry on large-area surfaces easy. One side of the chamber is left open, where the sample is to be placed. The sample acts as a chamber wall and therby defeins the detector volume. The sample area can be as large as 400 cm 2 . To prevent air from entering the volume there is a constant gas flow through the detector, coming in at the bottom of the chamber and leaking at the sides of the sample. The method results in good energy resolution and has considerable applicability in the retrospective radon research. Alpha spectra obtained in the retrospective measurements descend from 210 Po, built up in the sample from the radon daughters recoiled into a glass surface. (au)

  9. cap alpha. -spectra hyperfine structure resolution by silicon planar detectors

    Energy Technology Data Exchange (ETDEWEB)

    Eremin, V K; Verbitskaya, E M; Strokan, N B; Sukhanov, V L; Malyarenko, A M

    1986-10-01

    The lines with 13 keV step from the main one is ..cap alpha..-spectra of nuclei with an odd number of nucleons take place. Silicon planar detectors n-Si with the operation surface of 10 mm/sup 2/ are developed for resolution of this hyperfine structure. The mechanism of losses in detectors for short-range-path particles is analyzed. The results of measurements from detectors with 10 keV resolution are presented.

  10. Some applications of Photon/Electron-Rejecting Alpha Liquid Scintillation (PERALS) spectrometry to the assay of alpha emitters

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1988-01-01

    The combination of certain solvent extraction separations and a special kind of liquid scintillation detector and electronics designed for alpha spectrometry allows some highly accurate, yet simple determinations of alpha-emitting nuclides. Counting efficiency is 99.68% with backgrounds of 99.95%. The Photon/Electron Rejecting Alpha Liquid Scintillation (PERALS) equipment is described and procedures for the separation and determination of uranium, thorium, plutonium, polonium, radium, and trivalent actinides are outlined. 25 refs., 10 figs., 1 tab

  11. Alpha spectrometry enriched uranium urinalysis results from IPEN

    International Nuclear Information System (INIS)

    Lima, Marina Ferreira

    2008-01-01

    Full text: IPEN (Instituto de Pesquisas Energeticas e Nucleares) manufactures the nuclear fuel to its research reactor, the IEA-R1. The CCN (Centro do Ciclo do Combustivel) facility produces the fuel cermets from UF 6 (uranium hexafluoride) enriched to 19.75% in 235 U. The production involves the transformation of the gaseous form in oxides and silicates by ceramic and metallurgical processing. The workers act in more than one step that involves exposition to types F, S and M compounds of uranium. Until 2003, only fluorimetric analysis was carried out by the LRT (Laboratorio de Radiotoxicologia - IPEN) in order to evaluate the intake of uranium, in spite of the sub estimation of the 234 U contribution to the internal doses. Isotopic uranium determination in urine by alpha spectrometry is the current method to monitoring the contribution of 234 U, 235 U and 238 U. Alpha spectrometry data of 164 samples from 84 individuals separate in three categories of workers: routinely work group; special operation group and control group - were analyzed how the isotopic composition excreted by urinary tract corresponds with the level of enrichment and isotopic composition of the plant products. Results show that is hard to estimate these intakes of 234 U and 235 U since these isotopes alpha activities are below the limit of detection or minimum detectable activity (MAD) of this method in the most part of the samples. Only in 22 samples it was possibly to measure the three radionuclides. Not expected high contribution of 234 U activity was found in samples of the control group. No one result over the 234 U and 235 U MAD was found in the samples from the special operation group. Only in 5 samples from the routinely group the levels of 235 U was higher than the levels of others groups. In a complementary study, 3 solid samples of UF 6 , U 2 O 8 and U 3 Si 2 from CCN plant were analyzed to determinate the isotopic uranium composition in these salts, since this composition varies

  12. Bulk GaN alpha-particle detector with large depletion region and improved energy resolution

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Qiang; Mulligan, Padhraic [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210 (United States); Wang, Jinghui [Department of Radiology, Stanford University, 1201 Welch Rd, Stanford, CA 94305 (United States); Chuirazzi, William [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210 (United States); Cao, Lei, E-mail: cao.152@osu.edu [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210 (United States)

    2017-03-21

    An alpha-particle detector was fabricated using a freestanding n-type bulk GaN wafer with a Au/Ni/GaN sandwich Schottky structure. Current–voltage measurements at room temperature revealed a Schottky contact with a leakage current of 7.53±0.3 nA at a reverse bias of 200 V. The detector had a large depletion depth that can capture much of the energy from 5.486 MeV alpha particles emitted from a {sup 241}Am source. The resolution of its alpha-particle energy spectrum was improved to 2.2±0.2% at 5.486 MeV under a bias of 550 V. This superior resolution was attributed to the shortening of the carrier transit time and the large energy deposition within the large depletion depth, i.e., 27 µm at −550 V, which all resulted in a more complete charge collection. A model developed using the ATLAS simulation framework from Silvaco Inc. was employed to study the charge collection process. The simulation results were found to agree closely with the experimental results. This detector will be beneficial for research at neutron scattering facilities, the International Thermonuclear Experimental Reactor, and the Large Hadron Collider, among other institutions, where the Si-based charged particle detectors could be quickly degraded in an intense radiation field. - Highlights: • An alpha-particle detector based on a Schottky-structured GaN wafer was tested. • The detector's large depletion depth enables fuller energy spectra to be obtained. • The best resolution yet attained in GaN alpha-particle spectrometry was achieved. • The detector's short carrier transit time resulted in improved charge collection. • This detector is usable in extreme conditions, including intense radiation fields.

  13. Yeast expression proteomics by high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Walther, Tobias C; Olsen, Jesper Velgaard; Mann, Matthias

    2010-01-01

    -translational controls contribute majorly to regulation of protein abundance, for example in heat shock stress response. The development of new sample preparation methods, high-resolution mass spectrometry and novel bioinfomatic tools close this gap and allow the global quantitation of the yeast proteome under different...

  14. Noise and resolution with digital filtering for nuclear spectrometry

    International Nuclear Information System (INIS)

    Lakatos, T.

    1991-01-01

    Digital noise filtering looks very promising for semiconductor spectrometry. The resolution and conversion speed of the analog to digital converter (ADC) used at the input of a digital signal processor and analyzer can strongly influence the signal to noise ratio, the peak position and shape. The article leads with the investigation of these effects using computer modelling. (orig.)

  15. Determination of /sup 226/Ra by alpha spectrometry of liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Nobrega, A W; Sachett, I A; Hespanhol, E C.B.

    1987-07-01

    The determination of /sup 226/Ra in environmental samples using alpha spectrometry in liquid scintilation is studied. The Radon/sup 1-2/ emanation method and /sup 226/Ra separation process of other radionuclides alpha emissors are analyzed. The use of /sup 226/Ra coprecipitation with barium sulphate is evaluated. (M.J.C.).

  16. High Resolution Mass Spectrometry of Polyfluorinated Polyether-Based Formulation

    DEFF Research Database (Denmark)

    Dimzon, Ian Ken; Trier, Xenia; Frömel, Tobias

    2016-01-01

    High resolution mass spectrometry (HRMS) was successfully applied to elucidate the structure of a polyfluorinated polyether (PFPE)-based formulation. The mass spectrum generated from direct injection into the MS was examined by identifying the different repeating units manually and with the aid o......-fluorinated polymers. The information from MS is essential in studying the physico-chemical properties of PFPEs and can help in assessing the risks they pose to the environment and to human health. Graphical Abstract ᅟ....

  17. Experiences with large-area frisch grid chambers in low-level alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Winkler, R. (Gesellschaft fuer Strahlen- und Umweltforschung m.b.H. Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz)

    1984-06-15

    The properties of parallel-plate gridded ionization chambers with areas of 300 cm/sup 2/, developed by us for alpha spectrometry of samples with low specific alpha activity are reported. Several practical hints for optimum operating conditions are presented. The chambers can be operated routinely at atmospheric pressure for several days, without the need for purification of the gas filling (P10). The minimum detectable activity at 5 MeV is 0.01 pCi, based on 4.65 standard deviations of background and 1000 min counting time. At the GSF Research Center ionization chambers of this type are used for the analysis of natural alpha emitters, as well as of transuranium nuclides in environmental samples by: a) direct alpha spectrometry without any previous treatment of the sample, b) semi-direct spectrometry after removal of organic matter by low-temperature ashing and c) spectrometry after chemical separation. Some typical example of application are given. Furthermore the range of application of the chambers in comparison to semiconductor detectors in the field of low-level alpha spectrometry is discussed.

  18. Experiences with large-area frisch grid chambers in low-level alpha spectrometry

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1984-01-01

    The properties of parallel-plate gridded ionization chambers with areas of 300 cm 2 , developed by us for alpha spectrometry of samples with low specific alpha activity are reported. Several practical hints for optimum operating conditions are presented. The chambers can be operated routinely at atmospheric pressure for several days, without the need for purification of the gas filling (P10). The minimum detectable activity at 5 MeV is 0.01 pCi, based on 4.65 standard deviations of background and 1000 min counting time. At the GSF Research Center ionization chambers of this type are used for the analysis of natural alpha emitters, as well as of transuranium nuclides in environmental samples by: a) direct alpha spectrometry without any previous treatment of the sample, b) semi-direct spectrometry after removal of organic matter by low-temperature ashing and c) spectrometry after chemical separation. Some typical example of application are given. Furthermore the range of application of the chambers in comparison to semiconductor detectors in the field of low-level alpha spectrometry is discussed. (orig.)

  19. Bayesian Peptide Peak Detection for High Resolution TOF Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianqiu; Zhou, Xiaobo; Wang, Honghui; Suffredini, Anthony; Zhang, Lin; Huang, Yufei; Wong, Stephen

    2010-11-01

    In this paper, we address the issue of peptide ion peak detection for high resolution time-of-flight (TOF) mass spectrometry (MS) data. A novel Bayesian peptide ion peak detection method is proposed for TOF data with resolution of 10 000-15 000 full width at half-maximum (FWHW). MS spectra exhibit distinct characteristics at this resolution, which are captured in a novel parametric model. Based on the proposed parametric model, a Bayesian peak detection algorithm based on Markov chain Monte Carlo (MCMC) sampling is developed. The proposed algorithm is tested on both simulated and real datasets. The results show a significant improvement in detection performance over a commonly employed method. The results also agree with expert's visual inspection. Moreover, better detection consistency is achieved across MS datasets from patients with identical pathological condition.

  20. Sensitivity of DF-ICP-MS, PERALS and alpha-spectrometry for the determination of actinides. A comparison

    International Nuclear Information System (INIS)

    Ayranov, M.; Kraehenbuehl, U.

    2009-01-01

    We applied three techniques (DF-ICP-MS, PERALS and alpha-spectrometry) for the determination of minor actinides at environmental levels. For each method the limit of detection and the resolution were estimated in order to study the content and isotopic composition of the actinides. Two international reference materials, IAEA-135 (Irish Sea Sediment) and IAEA-300 (Baltic Sea sediment) were analyzed for activity concentrations of 238 Pu, 239 Pu, 240 Pu, 241 Pu and 241 Am. The sensitivities of the three determination techniques were compared. (author)

  1. High-resolution Lyman-alpha filtergrams of the sun

    Science.gov (United States)

    Bonnet, R. M.; Decaudin, M.; Bruner, E. C., Jr.; Acton, L. W.; Brown, W. A.

    1980-01-01

    The results of an experiment, conducted jointly by the Lockheed Palo Alto Research Laboratory and the Laboratoire de Physique Stellaire et Planetaire du CNRS, which investigated the transition-region plasma and the geometry of coronal active regions, in relation to models of the high-temperature layers, are presented. A Black Brant rocket was used to obtain 1-arc sec resolution L-alpha pictures of the sun, which revealed small scale features not seen previously at this wavelength, that delineate the geometry of the magnetic field in the chromosphere and in the corona. It is concluded that these observations might provide a new way of observing the upper chromosphere and corona, and that they provide direct evidence of the inhomogeneous character of the chromosphere and of the dominant role of the magnetic field

  2. Radiometric dating by alpha spectrometry on uranium series nuclides

    NARCIS (Netherlands)

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste

  3. Improved sample preparation method for environmental plutonium analysis by ICP-SFMS and alpha-spectrometry

    International Nuclear Information System (INIS)

    Varga, Z.; Stefanka, Z.; Suranyi, G.; Vajda, N.

    2007-01-01

    A rapid and simple sample preparation method for plutonium determination in environmental samples by inductively coupled plasma sector field mass spectrometry (ICP-SFMS) and alpha-spectrometry is described. The developed procedure involves a selective CaF 2 co-precipitation for preconcentration followed by extraction chromatographic separation. The proposed method effectively eliminates the possible interferences in mass spectrometric analysis and also removes interfering radionuclides that may disturb alpha-spectrometric measurement. For 239 Pu, 240 Pu and 241 Pu limits of detection of 9.0 fg x g -1 (0.021 mBq), 1.7 fg x g -1 (0.014 mBq) and 3.1 fg x g -1 (11.9 mBq) were achieved by ICP-SFMS, respectively, and 0.02 mBq by alpha-spectrometry. Results of certified reference materials agreed well with the recommended values. (author)

  4. Micro-precipitation of Americium by Cerium Hydroxide for alpha spectrometry

    International Nuclear Information System (INIS)

    Wankhede, Sonal M.; Kumar, Suja A.; Sawant, Pramilla D.

    2018-01-01

    Estimation of trace amount of actinides in any biological and/or environmental sample is done by radiochemical separation followed by alpha spectrometry. Alpha-spectrometric determination of actinides requires thin, homogeneous and nearly weightless sample sources. The most widely used method for preparation of actinides for alpha spectrometry involves electro deposition of the alpha emitters using stainless steel planchetts (cathode) and platinum rod (anode). This procedure is time consuming, requires relatively elaborate equipment, and is expensive. Micro-precipitation technique using hydrofluoric acid (HF) is also reliable and already standardized at Bioassay Laboratory (Wankhede, 2016). However, it uses hazardous chemical such as HF, hence, in the present study, cerium hydroxide micro-precipitation technique was standardized

  5. A simple source preparation method for alpha-ray spectrometry of volcanic rock sample

    International Nuclear Information System (INIS)

    Takahashi, Masaomi; Kurihara, Yuichi; Sato, Jun

    2006-01-01

    A simple source preparation method was developed for the alpha-ray spectrometry to determine U and Th in volcanic rockes. Isolation of U and Th from volcanic rocks was made by use of UTEVA-Spec. resin, extraction chromatograph material. U and Th were extracted by TTA-benzene solution and organic phase was evaporated drop by drop on a hot stainless steel planchet to dryness. This method was found to be effective for the preparation of sources for alpha-ray spectrometry. (author)

  6. Diesel characterization by high-resolution mass spectrometry - gas chromatography

    International Nuclear Information System (INIS)

    Baldrich, C.A

    1998-01-01

    High-resolution mass spectrometry-gas chromatography is combined with the HC22 method in order to obtain detailed information about the chemical composition of diesel and the distribution of different compound types in terms of its final boiling temperature from a single analysis. The total time elapsed from sample injection and signal processing to obtain final results is 90 minutes. This fact makes this methodology a new and very important tool for the decision making process concerning the most suitable final boiling temperature and the type of treatment of the product in order to obtain diesel that fulfills the international standards. The consistency and repeatability of the experimental results are demonstrated

  7. Determination of ''226Ra by Alpha Spectrometry by Using ''225Ra as Yield Tracer

    International Nuclear Information System (INIS)

    Crespo, M. T.; Oller, O.

    1999-01-01

    A method for the determination of low-level ''226 Ra in environmental and geological samples by alpha spectrometry is described. The method is based on the use of ''225 Ra from ''229 Th as yield tracer and has been developed to analyze U, Th and Ra in the same sample. (Author) 12 refs

  8. Preparation of /sup 237/Np samples by electrodeposition and its determination by alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mertzig, W; Matsuda, H T; Araujo, B.F. de; Araujo, J.A. de [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil). Centro de Engenharia Quimica

    1980-01-01

    An analytical method followed by alpha spectrometry was developed for the determination of trace amounts of actinides. A technique for quantitative electrodeposition of /sup 237/Np, under optimal conditions, using a carrier, is presented. This method will be applied for the control of trace amounts of /sup 237/Np in the solutions from the reprocessing (Purex process) of irradiated uranium.

  9. Characterization of high level waste for minor actinides by chemical separation and alpha spectrometry

    International Nuclear Information System (INIS)

    Murali, M.S.; Bhattacharayya, A.; Kar, A.S.; Tomar, B.S.; Manchanda, V.K.

    2010-01-01

    Quantification of minor actinides present in of High Level Waste (HLW) solutions originating from the power reactors is important in view of management of radioactive wastes and actinide partitioning. Several methods such as ICP-MS, X-ray fluorescence methods, ICP-AES, alpha spectrometry are used in characterizing such types of wastes. As alpha spectrometry is simple and reliable, this technique has been used for the estimation of minor actinides after devising steps of separation for estimating Np and Pu present in HLW solutions of PHWR origin. Using a wealth of knowledge appropriate to the solution chemistry of actinides, the task of separation, though appears easy, it is challenging job for a radiochemist handling high-dose HLW samples, for obtaining clean alpha peaks for Np and Pu. This paper reports on the successful attempt made to quantify 241 Am, 244 Cm, Pu (239 mainly) and 237 Np present in HLW-PHWR obtained from PREFRE, Tarapur

  10. Determination of Uranium plus Plutonium by Alpha spectrometry in different matrix

    International Nuclear Information System (INIS)

    Equillor, Hugo E.; Campos, Juan M.

    2011-01-01

    Usually, the determination of alpha emitters by alpha spectrometry is performed with a prior purification of each of the elements to be quantified. In this work, a methodology for the determination of uranium and plutonium isotopes as jointly described, in order to improve analytical processing times and measurement. The method includes purifying uranium and plutonium, and the subsequent electrodeposition for alpha spectrometry measurement. The technique is based on the use of TBP (tributyl phosphate) as extractant and easy to obtain reactants. It is applicable to various matrices, including water, filters and soils. In the conditions described, is applied to small aliquots of approximately 0.5 g of solid. The technique produces high quality electrodeposits. (authors) [es

  11. Boundaries of mass resolution in native mass spectrometry.

    Science.gov (United States)

    Lössl, Philip; Snijder, Joost; Heck, Albert J R

    2014-06-01

    Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)-protein interactions, to nanomachineries such as the proteasome and ribosome, to even virus assembly. In native MS, ions attain high m/z values, requiring special mass analyzers for their detection. Depending on the particular mass analyzer used, instrumental mass resolution does often decrease at higher m/z but can still be above a couple of thousand at m/z 5000. However, the mass resolving power obtained on charge states of protein complexes in this m/z region is experimentally found to remain well below the inherent instrument resolution of the mass analyzers employed. Here, we inquire into reasons for this discrepancy and ask how native MS would benefit from higher instrumental mass resolution. To answer this question, we discuss advantages and shortcomings of mass analyzers used to study intact biomolecules and biomolecular complexes in their native state, and we review which other factors determine mass resolving power in native MS analyses. Recent examples from the literature are given to illustrate the current status and limitations.

  12. Measurement of 233U/234U ratios in contaminated groundwater using alpha spectrometry

    International Nuclear Information System (INIS)

    Harrison, Jennifer J.; Payne, Timothy E.; Wilsher, Kerry L.; Thiruvoth, Sangeeth; Child, David P.; Johansen, Mathew P.; Hotchkis, Michael A.C.

    2016-01-01

    The uranium isotope 233 U is not usually observed in alpha spectra from environmental samples due to its low natural and fallout abundance. It may be present in samples from sites in the vicinity of nuclear operations such as reactors or fuel reprocessing facilities, radioactive waste disposal sites or sites affected by clandestine nuclear operations. On an alpha spectrum, the two most abundant alpha emissions of 233 U (4.784 MeV, 13.2%; and 4.824 MeV, 84.3%) will overlap with the 234 U doublet peak (4.722 MeV, 28.4%; and 4.775 MeV, 71.4%), if present, resulting in a combined 233+234 U multiplet. A technique for quantifying both 233 U and 234 U from alpha spectra was investigated. A series of groundwater samples were measured both by accelerator mass spectrometry (AMS) to determine 233 U/ 234 U atom and activity ratios and by alpha spectrometry in order to establish a reliable 233 U estimation technique using alpha spectra. The Genie™ 2000 Alpha Analysis and Interactive Peak Fitting (IPF) software packages were used and it was found that IPF with identification of three peaks ( 234 U minor, combined 234 U major and 233 U minor, and 233 U major) followed by interference correction on the combined peak and a weighted average activity calculation gave satisfactory agreement with the AMS data across the 233 U/ 234 U activity ratio range (0.1–20) and 233 U activity range (2–300 mBq) investigated. Correlation between the AMS 233 U and alpha spectrometry 233 U was r 2  = 0.996 (n = 10). - Highlights: • Describes a technique for deconvoluting the combined 233 U and 234 U multiplet in alpha spectra. • Enables 233 U and 234 U activities and 233 U/ 234 U ratios to be quantified without requiring additional analysis and measurement. • Applicable to an environmental matrix (groundwater) using standard alpha spectrometry counting equipment, operation and set-up.

  13. Linking high resolution mass spectrometry data with exposure ...

    Science.gov (United States)

    There is a growing need in the field of exposure science for monitoring methods that rapidly screen environmental media for suspect contaminants. Measurement and analysis platforms, based on high resolution mass spectrometry (HRMS), now exist to meet this need. Here we describe results of a study that links HRMS data with exposure predictions from the U.S. EPA's ExpoCast™ program and in vitro bioassay data from the U.S. interagency Tox21 consortium. Vacuum dust samples were collected from 56 households across the U.S. as part of the American Healthy Homes Survey (AHHS). Sample extracts were analyzed using liquid chromatography time-of-flight mass spectrometry (LC–TOF/MS) with electrospray ionization. On average, approximately 2000 molecular features were identified per sample (based on accurate mass) in negative ion mode, and 3000 in positive ion mode. Exact mass, isotope distribution, and isotope spacing were used to match molecular features with a unique listing of chemical formulas extracted from EPA's Distributed Structure-Searchable Toxicity (DSSTox) database. A total of 978 DSSTox formulas were consistent with the dust LC–TOF/molecular feature data (match score ≥ 90); these formulas mapped to 3228 possible chemicals in the database. Correct assignment of a unique chemical to a given formula required additional validation steps. Each suspect chemical was prioritized for follow-up confirmation using abundance and detection frequency results, along wi

  14. Radiometric dating by alpha spectrometry on uranium series nuclides

    International Nuclear Information System (INIS)

    Wijk, A. van der.

    1987-01-01

    This thesis describes the analytical and technical procedures that are required for routine application of both the 230 Th/ 234 U disequilibrium dating method for peat and the 210 Pb dating method for lake sediments. Its principal aim is to test, refine and discuss the reliability and validity of these methods. On the other hand, the analytical procedures that were introduced open a wide range of other interesting fields of research that are not necessarily restricted to geological problems only. Chapter 5 reports an obviously not foreseen application: detection of alpha emitting nuclides released in the first weeks of May, 1986 during the accident with the nuclear power plant in Chernobyl, USSR. 128 refs.; 43 figs.; 15 tabs

  15. Determination of Uranium, Thorium and Radium 226 in Zircon containig sands by alpha spectrometry

    International Nuclear Information System (INIS)

    Spezzano, P.

    1985-01-01

    The industrial utilization of Zircon sands for the production of refractories presents radiological problems owing to the risk of inhalation of Uranium, Thorium and their decay products, present in high concentrations in such materials. A method of analysis was realized for the determination of Uranium, Thorium and Radium-226 in Zircon sands, including the total dissolution of the sample, radiochemical separation and final measurement by alpha spectrometry with surface barrier detector. The concentrations of the main alpha-emitting radionuclides presents in two samples of Zircon sands have been determined and the possibility of disequilibrium along the decay series has been pointed out

  16. Alpha spectrometry of thick sources. I. Application to alpha emitters determination

    International Nuclear Information System (INIS)

    Acena, M.L.; Garcia-Torano, E.; Rivero, M.C.

    1977-01-01

    A method for determining alpha emitters by silicon surface barrier detector spectroscopy using thick sources is studied. Two types of spectra have been obtained. They have different shapes of line according to the procedure used for preparing the sources. For both spectra a computing least square programme has been developed. In this way it is possible to calculate line intensities with accuracy better than 20 percent. (author) [es

  17. Quantitation of Acrylamide in Foods by High-Resolution Mass Spectrometry

    NARCIS (Netherlands)

    Troise, A.D.; Fogliano, Vincenzo

    2016-01-01

    The use of liquid chromatography high-resolution mass spectrometry (LC-HRMS) and direct analysis real-time high-resolution mass spectrometry (DART-HRMS) defines a new scenario in the analysis of thermal-induced toxicants, such as acrylamide. Several factors contribute to the definition of the

  18. Microprecipitation of barium sulfate as a suitable source for measurements of 226Ra by alpha spectrometry

    International Nuclear Information System (INIS)

    Fernandez-Cata, Geyser; Isaac-Olive, Keila : E-mail. geyser@instec.cu

    2007-01-01

    One of the most hazardous radionuclides released into the environment is the uranium's daughter 226 Ra. This nuclide behaves similar to calcium, therefore is highly toxic for humans. One of the suitable methods for its determination is alpha spectrometry. This technique, however, has as main drawback the source preparation which should be infinitely thin and massless, of regular, known, and reproducible shape, smaller in area than the active area of the detector and new (no sputtering or recoil losses). Among the various ways of preparing an alpha source are the electrodeposition and microprecipitation. Radium electrodeposition is not suitable to carry out because of the high reduction potential of this element, therefore non aqueous media is required and the chemical yield is not good. Radium however can be precipitated with barium sulfate and our previous work has shown that the precipitation is selective to this element in the presence of other alpha emitters such as uranium and polonium but divalent cations are incorporated to it. At the same time, manganese dioxide also precipitates radium free of divalent cations but alpha emitters such as uranium are present as well. The objective of this work was to establish a chemical procedure for the determination of 226 Ra in natural water by alpha spectrometry. The general methodology includes a preconcentration using a non selective coprecipitation via manganese dioxide (where cations are not included but alpha emitters do). Once the manganese dioxide is filtrated, it is re-dissolved and a selective microprecipitation using barium sulphate is carried out (where the only alpha emitter is radium). Details of the procedure, separation methods, source quality and discussion of the results will be given in the paper. (Author)

  19. Proceedings of the International Symposium Advances in alpha, Beta- and Gamma-Ray spectrometry

    International Nuclear Information System (INIS)

    1997-01-01

    The International Committee for Radionuclide Metrology (ICRM) is an association of radionuclide metrology laboratories whose membership is composed of delegates of these laboratories together with other scientists actively engaged in the study and applications of radioactivity. The scientific activities are carried out in the frame of six Working Groups. Two of them, the Alpha-Particle Spectrometry and the Gamma-and Beta-ray Spectrometry Working Groups held a common workshop in Pushkin, St. Petersburg, 18 to 20 September 1996, under the title Advances in Alpha-Beta-and Gamma-Ray Sepectrometry, at the kind invitation of the D.I. Mendeleyev Institute for Metrology. More than 30 people from 14 laboratories attended the meeting, and nineteen oral communications were presented, from which twelve were retained for publication an are included in these proceedings. (Author)

  20. Determination of the-230 on urine by means of alpha spectrometry

    International Nuclear Information System (INIS)

    1992-01-01

    The measurements of activity on urine samples are data very important to evaluation the internal doses. We have developed a radiochemistry method with the measure of Th-230 in urine. The method is based in the coprecipitation of the like phosphate the activity of sample is determined by alpha spectrometry. We use like tracer Th-234. The results show a recuperation between 65%-85%

  1. Target characterization by PIXE, alpha spectrometry and X-ray absorption

    International Nuclear Information System (INIS)

    Kheswa, N.Y.; Papka, P.; Pineda-Vargas, C.A.; Newman, R.T.

    2011-01-01

    We report on the thickness and homogeneity characterization of thin metallic targets of Zr-96 by means of alpha absorption spectrometry, Particle Induced X-ray Emission (PIXE) and X-ray absorption. The target thicknesses determined by means of the above mentioned methods are critically compared. The thicknesses were determined before and after irradiation with a 70 MeV beam of 14 N ions.

  2. Alpha spectrometry of thick sources. II. Application to the study of radioactive equilibria in uranium ores

    International Nuclear Information System (INIS)

    Acena Barrenechea, M.L.; Tormo Ferrero, M.J.

    1977-01-01

    A method for determining nuclide activities in 4n + 2 uranium series using alpha spectrometry of thick sources is described. This method has been applied to several uranium ores, showing different states of radioactive equilibria. The spectra from samples prepared by cold compression show some anomalies, due to the evolution and later decay of 219 Rn and daughters. This phenomenon must be taken in consideration when computing spectra line intensities. (author) [es

  3. Determination of C and O and other elements by alpha-induced X-ray energy spectrometry

    International Nuclear Information System (INIS)

    Henningsen, W.P.; Schaetzler, H.P.; Kuehn, W.

    1978-01-01

    X-ray energy spectrometry combined with alpha-excitation by means of radionuclides, especially Po-210, has been found as a versatile tool for multielement analysis. Down to Z = 6 (carbon) qualitative and quantitative measurements have been carried out with energy resolution good enough to separate adjacent elements. Thereby errors and lowest detectable concentrations were in the region of one percent. By utilizing M- and L-X-radiation the set of detectable elements can be opened to high atomic numbers. As an example with special regard to environmental research cadmium in organic matrix was measured down to 100 ppm without any preconcentration. Much lower detection limits might be reached by appropriate measures. (orig.) [de

  4. Rapid monitoring of soil, smears, and air dusts by direct large-area alpha spectrometry

    International Nuclear Information System (INIS)

    Sill, C.W.

    1992-01-01

    Experimental conditions to permit rapid monitoring of soils, smears, and air dusts for transuranic (TRU) radionuclides under field conditions are described. The monitoring technique involves direct measurement of alpha emitters by alpha spectrometry using a large-area detector to identify and quantify the radionuclides present. The direct alpha spectrometry employs a circular gridded ionization chamber 35 cm in diameter which accommodates either a circular sample holder 25 cm in diameter or a rectangular one 20 by 25 cm (8 by 10 in.). Soils or settled dusts are finely ground, suspended in 30% ethanol, and sprayed onto a 25-cm stainless steel dish. Air dusts are collected with a high-volume sampler onto 20- by 25-cm membrane filters. Removable contamination is collected from surfaces onto a 20- by 25-cm filter using an 18-cm (7-in.) paint roller to hold the large filter in contact with the surface during sample collection. All three types of samples are then counted directly in the alpha spectrometer and no other sample preparation is necessary. Some results obtained are described

  5. AIRFIL: a FORTRAN program for reduction of data obtained from alpha spectrometry of perimeter air filters

    International Nuclear Information System (INIS)

    Hinton, E.R. Jr.; Howell, R.L.

    1984-03-01

    Isotopic alpha spectrometry of 238 U, 235 U, and 234 U, along with gross alpha/beta counting of perimeter air filters, is performed by the Oak Ridge Y-12 Plant Laboratory in support of the Envrirnomental Monitoring Section of the Radiation Safety Department. Weekly samples are gross alpha/beta counted and the isotopic analysis performed on quarterly composites. Calculations and data management represents a major portion of the anlaysis time when performed manually, even with a desktop calculator. In order to reduce calculation time, perform orderly data manipulation and management, reduce errors due to redundant calculations, and eliminate report typing turnaround time, a computer program (AIRFIL) has been developed that performs these functions. The program accepts data through user prompts, then calculates and prints intermediate and final data, including detection limits

  6. High Resolution Mass Spectrometry of Polyfluorinated Polyether-Based Formulation

    Science.gov (United States)

    Dimzon, Ian Ken; Trier, Xenia; Frömel, Tobias; Helmus, Rick; Knepper, Thomas P.; de Voogt, Pim

    2016-02-01

    High resolution mass spectrometry (HRMS) was successfully applied to elucidate the structure of a polyfluorinated polyether (PFPE)-based formulation. The mass spectrum generated from direct injection into the MS was examined by identifying the different repeating units manually and with the aid of an instrument data processor. Highly accurate mass spectral data enabled the calculation of higher-order mass defects. The different plots of MW and the nth-order mass defects (up to n = 3) could aid in assessing the structure of the different repeating units and estimating their absolute and relative number per molecule. The three major repeating units were -C2H4O-, -C2F4O-, and -CF2O-. Tandem MS was used to identify the end groups that appeared to be phosphates, as well as the possible distribution of the repeating units. Reversed-phase HPLC separated of the polymer molecules on the basis of number of nonpolar repeating units. The elucidated structure resembles the structure in the published manufacturer technical data. This analytical approach to the characterization of a PFPE-based formulation can serve as a guide in analyzing not just other PFPE-based formulations but also other fluorinated and non-fluorinated polymers. The information from MS is essential in studying the physico-chemical properties of PFPEs and can help in assessing the risks they pose to the environment and to human health.

  7. HCN Polymers: Toward Structure Comprehension Using High Resolution Mass Spectrometry

    Science.gov (United States)

    Bonnet, Jean-Yves; Thissen, Roland; Frisari, Ma; Vuitton, Veronique; Quirico, Eric; Le Roy, Léna; Fray, Nicolas; Cottin, Hervé; Horst, Sarah; Yelle, Roger

    A lot of solar system materials, including cometary ices and Titan aerosols, contain dark matter that can be interpreted as complex nitrogen bearing organic matter [1]. In laboratory experi-ments, HCN polymers are thus analogs of great interest. In fact they may be present in Titan atmosphere and in comet nuclei and then reprocessed as a CN distributed source [2], when ices began to sublimate and ejects from the nucleus organic matter grains [3]. The presence of HCN polymers is suggested because HCN molecule has been directly observed in 1P/Halley comet [4] and others. HCN polymers are also of prebiotic interest [5] as it can form amino acid under hydrolysis conditions. Even if they have been studied during the last decades, their chemical composition and structure are still poorly understood, and a great analytical effort has to be continued. In this way we present a high resolution mass spectrometry (HRMS) and a high resolution tandem mass spectrometry (MS/HRMS) analysis of HCN polymers. It was shown [6] that this is a suitable technique to elucidate composition and structure of the soluble part of tholins analogs of Titan's atmosphere aerosols. HCN polymers have never been studied by HRMS, thus we used a LTQ-Orbitrap XL high resolution mass spectrometer to analyse the HCN polymers. These are produced at LISA by direct polymerisation of pure liquid HCN, catalyzed by ammonia. HCN polymers have been completely dissolved in methanol and then injected in the mass spectrometer by ElectroSpray Ionization (ESI). This atmospheric pressure ionization process produces protonated or deprotonated ions, but it does not fragment molecules. Thus HRMS, allows a direct access to the stoechiometry of all the ionizable molecules present in the samples. Fragmentation analyses (MS/MS) of selected ions have also been performed. Thess analysis provide information about the different chemical fonctionnalities present in HCN poly-mers and also about their structure. Thus we are able to

  8. Large area gridded ionisation chamber and electrostatic precipitator and their application to low-level alpha-spectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1977-01-01

    A high-resolution, parallel plate Frisch grid ionization chamber with an efficient area of 3000 cm 2 , and a large area electrostatic precipitator were developed and applied to direct alpha spectrometry of air dust. Using an argon-methane mixture (P-10 gas) at atmospheric pressure the resolution of the detector system is 22 keV FWHM at 5 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha emitters is about 0.1 fCi/m 3 taking 3 Σσ of background as the detection limit with 1000 min counting time. (author)

  9. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. High-resolution Lyman-alpha filtergrams of the sun

    International Nuclear Information System (INIS)

    Bonnet, R.M.; Bruner, E.C. Jr.; Acton, L.W.; Brown, W.A.; Decaudin, M.

    1980-01-01

    1'' resolution Lα pictures of the Sun have been obtained during the flight of a Black Brant rocket which took place on 1979 July 3. These pictures reveal many new structures never seen before on Lα spectroheliograms. The instrumentation, flight conditions, and preliminary results are described

  11. The determination of radium-226 in uranium ores and mill products by alpha energy spectrometry

    International Nuclear Information System (INIS)

    Zimmerman, J.B.; Armstrong, V.C.

    1975-12-01

    A reliable routine procedure for determining 226 Ra by alpha energy spectrometry is described. Radium is isolated as sulphate from the sample matrix by co-precipitation with a small mass of barium and analysed using a ruggedized silicon surface barrier detector. The method is capable of providing high accuracy over a large 226 Ra concentration range and is applicable to materials such as uranium ores, uranium mill products and effluent streams. Samples resulting from nitric acid leach experiments with Elliot Lake ores were examined using the procedure. The distribution of 223 Ra, 224 Ra and 226 Ra between the leach products, (residue and leach liquor), is discussed. (author)

  12. Concentration of Uranium Radioisotopes in Albanian Drinking Waters Measured by Alpha Spectrometry

    Science.gov (United States)

    Bylyku, Elida; Cfarku, Florinda; Deda, Antoneta; Bode, Kozeta; Fishka, Kujtim

    2010-01-01

    Uranium is a radioactive material that is frequently found in rocks and soil. When uranium decays, it changes into different elements that are also radioactive, including radon, a gas that is known to cause a lung cancer. The main concern with uranium in drinking water is harm to the kidneys. Public water systems are required to keep uranium levels at or below 500 mBq per liter to protect against kidney damage. Such an interest is needed due to safety, regulatory compliance and disposal issue for uranium in the environment since uranium is included as an obligatory controlled radionuclide in the European Legislation (Directive 98/83 CE of Council of 03.11.1998). The aim of this work is to measure the levels of uranium in drinking and drilled well waters in Albania. At first each sample was measured for total Alpha and total Beta activity. The samples with the highest levels of total alpha activity were chosen for the determination of uranium radioisotopes by alpha spectrometry. A radiochemical procedure using extraction with TBP (Tri-Butyl-Phosphate) is used in the presence of U232 as a yield tracer. Thin sources for alpha spectrometry are prepared by electrodepositing on to stainless steel discs. The results of the U238 activity measured in the different samples, depending from their geological origin range between 0.55-13.87 mBq/l. All samples measured results under the European Directive limits for U238 (5-500 mBq/1), Dose Coefficients according to Directive 96/29 EURATOM.

  13. Alpha spectrometry of environmental and food samples with photon/electron-rejecting alpha liquid-scintillation (P.E.R.A.L.S.)

    International Nuclear Information System (INIS)

    Zehringer, M.; Stockli, M.

    2006-01-01

    Full text: In environmental and food monitoring radio-nuclides are normally analysed with gamma spectrometry. Routine analysis of cesium nuclides can be realised fast and without much sample preparation. Also a few nuclides of the uranium- and thorium-series can be detected with gamma spectrometry at the low Bq/kg level. 226 Ra, 224 Ra and 228 Ra can be determined via their decay products when secular equilibrium of the sample is reached (e.g. 226 Ra via its daughters 214 Pb and 214 Bi). Alpha spectrometry is the method of choice for the determination of alpha nuclides in the mBq range. The analytes have to be separated from interfering nuclides and quenching parameters prior to the spectrometry. So, the main ask in alpha spectrometry consists in an efficient sample preparation and an alpha/beta discrimination for the spectrometric measurement. Based on the work of Jack McDowell sensitive methods for the analyses of naturally occurring nuclides such as uranium, thorium, polonium and other alpha-nuclides in water, honey and spices were developed and validated [1]. Such techniques enables the tolerance and limit values for radionuclides in food to be controlled in accordance with of the Swiss Ordinance on contaminants and Ingredients (FIV) [2] he method principle is based on a selective extraction of the alpha nuclides rom water samples rsp. from an aqueous extract of mineralized samples. The extractant has also the function of a cocktail in the alpha liquid spectrometry nd therefore the extract can be analysed directly without further clean -up Photon/Electron-Rejecting Alpha-Liquid-Scintillation, P.E.R.A.L..S. [1]). Normally, one liter of water sample is extracted with 5 ml of cocktail to achieve low detection limits. The cocktail phase is separated from the aqueous phase by use of a phase separator for liquid samples. Methods were developed for the analyses of 234 U and 238 U, the thorium nuclides 228 Th, 230 Th, 232 Th and other alpha nuclides. The achieved

  14. Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS).

    Science.gov (United States)

    Agarande, M; Benzoubir, S; Bouisset, P; Calmet, D

    2001-08-01

    Trace levels (pg kg(-1)) of 241Am in sediments were determined by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS) using a microconcentric nebulizer. 241Am was isolated from major elements like Ca and Fe by different selective precipitations. In further steps. Am was first separated from other transuranic elements and purified by anion exchange and extraction chromatography prior to the mass spectrometric measurements. The ID HR ICP-MS results are compared with isotope dilution alpha spectrometry.

  15. High Spatial Resolution Imaging Mass Spectrometry of Human Optic Nerve Lipids and Proteins

    Science.gov (United States)

    Anderson, David M. G.; Spraggins, Jeffrey M.; Rose, Kristie L.; Schey, Kevin L.

    2015-06-01

    The human optic nerve carries signals from the retina to the visual cortex of the brain. Each optic nerve is comprised of approximately one million nerve fibers that are organized into bundles of 800-1200 fibers surrounded by connective tissue and supportive glial cells. Damage to the optic nerve contributes to a number of blinding diseases including: glaucoma, neuromyelitis optica, optic neuritis, and neurofibromatosis; however, the molecular mechanisms of optic nerve damage and death are incompletely understood. Herein we present high spatial resolution MALDI imaging mass spectrometry (IMS) analysis of lipids and proteins to define the molecular anatomy of the human optic nerve. The localization of a number of lipids was observed in discrete anatomical regions corresponding to myelinated and unmyelinated nerve regions as well as to supporting connective tissue, glial cells, and blood vessels. A protein fragment from vimentin, a known intermediate filament marker for astrocytes, was observed surrounding nerved fiber bundles in the lamina cribrosa region. S100B was also found in supporting glial cell regions in the prelaminar region, and the hemoglobin alpha subunit was observed in blood vessel areas. The molecular anatomy of the optic nerve defined by MALDI IMS provides a firm foundation to study biochemical changes in blinding human diseases.

  16. Results obtained in a spectrometry using junction detectors (1962); Resultats en spectrometrie {alpha} a l'aide de ''detecteurs jonction'' (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Beaumevieille, H; Fontenille, J; Lottgequeue, J P; Longequeue, N; Rabour, C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    Junction detectors have been used for studying {alpha} spectra obtained by nuclear reactions (p, {alpha}), the protons being produced by an electrostatic accelerator (E{sub p} varying from 100 to 600 keV). Difficulties have been encountered arising from parasitic noise from the accelerator and from the distance (60 metres) between detectors and electronic equipment. Resolution of the counter has been found to be 0.6 per cent with {alpha} from {sup 210}Po and 1.2 pour cent with {alpha} (5.8 MeV) from the reaction {sup 11}B (p, {alpha}{sub 0}). (authors) [French] Des detecteurs a jonction ont ete utilises pour l'etude de spectres {alpha} obtenus par reactions nucleaires (p, {alpha}), les protons etant acceleres par un accelerateur electrostatique (E{sub p} variant de 100 a 600 keV). Des difficultes ont ete recontrees dues aux parasites provenant de l'accelerateur et a la distance des cables (60 metres) entre detecteurs et appareils de mesure. Le pouvoir de resolution de l'ensemble a ete de 0, 6 pour cent avec les {alpha} du {sup 210}Po et de 1,2 pour cent avec les {alpha} (5,8 MeV) de la reaction {sup 11}B (p, {alpha}{sub 0}). (auteurs)

  17. Fast-ion energy resolution by one-step reaction gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nocente, M.; Gorini, G.

    2016-01-01

    The spectral broadening of γ-rays from fusion plasmas can be measured in high-resolution gamma-ray spectrometry (GRS). We derive weight functions that determine the observable velocity space and quantify the velocity-space sensitivity of one-step reaction high-resolution GRS measurements in magne...

  18. Boundaries of mass resolution in native mass spectrometry

    NARCIS (Netherlands)

    Lössl, Philip|info:eu-repo/dai/nl/371559693; Snijder, Joost|info:eu-repo/dai/nl/338018328; Heck, Albert J R|info:eu-repo/dai/nl/105189332

    Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)-protein interactions, to nanomachineries such as the proteasome and ribosome, to even

  19. Using different drift gases to change separation factors (alpha) in ion mobility spectrometry

    Science.gov (United States)

    Asbury; Hill

    2000-02-01

    The use of different drift gases to alter separation factors (alpha) in ion mobility spectrometry has been demonstrated. The mobility of a series of low molecular weight compounds and three small peptides was determined in four different drift gases. The drift gases chosen were helium, argon, nitrogen, and carbon dioxide. These drift gases provide a range of polarizabilities and molecular weights. In all instances, the compounds showed the greatest mobility in helium and the lowest mobility in carbon dioxide; however the percentage change of mobility for each compound was different, effectively changing the alpha value. The alpha value changes were primarily due to differences in drift gas polarizability but were also influenced by the mass of the drift gas. In addition, gas-phase ion radii were calculated in each of the different drift gases. These radii were then plotted against drift gas polarizability producing linear plots with r2 values greater than 0.99. The intercept of these plots provides the gas-phase radius of an ion in a nonpolarizing environment, whereas the slope is indicative of the magnitude of the ion's mobility change related to polarizability. It therefore, should be possible to separate any two compounds that have different slopes with the appropriate drift gas.

  20. Rapid determination of radium-224/226 in seawater sample by alpha spectrometry.

    Science.gov (United States)

    Song, Lijuan; Yang, Yonggang; Luo, Maoyi; Ma, Yan; Dai, Xiongxin

    2017-05-01

    A new radiochemical separation method has been developed for rapid determination of alpha-emitting radium isotopes in seawater samples. This method can be applied for the measurement of 226 Ra in seawater samples when 224 Ra is used as tracer for chemical recovery correction. Likewise, 226 Ra can also be added as tracer for the determination of 224 Ra in seawater sample. In the method, radium is first pre-concentrated with hydrous titanium oxide (HTiO) and is purified by combined anion/cation exchange column chromatographic separation. The radium in the eluate is then co-precipitated with HTiO, dissolved in 9 M H 2 SO 4 , and followed through a BaSO 4 micro-precipitation step to prepare a thin-layer counting source to determine the activities of 224 Ra/ 226 Ra by alpha spectrometry. Replicate spike and blank samples were measured to evaluate the performance of the procedure. The minimum detectable activity concentration was determined to be 0.5 mBq·L -1 for 226 Ra and 0.4 mBq·L -1 for 224 Ra in 1 L of seawater sample with a counting time of 48 h. The method is a promising candidate for rapid measurement for alpha-emitting Ra isotopes in a large population of environment water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Comparison of the radiochemical separation procedures od plutonium applied for its determination in the environmental samples using alpha spectrometry

    International Nuclear Information System (INIS)

    Komosa, A.; Michalik, S.

    2006-01-01

    Alpha spectrometry of the plutonium isotopes can be performed only after the perfect plutonium separation from other components of the matrix. So, till now numerous procedures have been elaborated and tested. The communication presents comparison of the plutonium content determination in soil, bones, eggshells and in the reference materials obtained by alpha spectrometry combined with two different separation procedures. The samples were mineralized in the concentrated HCl or HF prior to plutonium electrodeposition or coprecipitation with NdF 3 . Some other details were also tested in various variants. Quality of the spectra is discussed in terms of all these pre-treatment methods

  2. Plasmodium vivax merozoite surface protein-3 alpha: a high-resolution marker for genetic diversity studies.

    Science.gov (United States)

    Prajapati, Surendra Kumar; Joshi, Hema; Valecha, Neena

    2010-06-01

    Malaria, an ancient human infectious disease caused by five species of Plasmodium, among them Plasmodium vivax is the most widespread human malaria species and causes huge morbidity to its host. Identification of genetic marker to resolve higher genetic diversity for an ancient origin organism is a crucial task. We have analyzed genetic diversity of P. vivax field isolates using highly polymorphic antigen gene merozoite surface protein-3 alpha (msp-3 alpha) and assessed its suitability as high-resolution genetic marker for population genetic studies. 27 P. vivax field isolates collected during chloroquine therapeutic efficacy study at Chennai were analyzed for genetic diversity. PCR-RFLP was employed to assess the genetic variations using highly polymorphic antigen gene msp-3 alpha. We observed three distinct PCR alleles at msp-3 alpha, and among them allele A showed significantly high frequency (53%, chi2 = 8.22, p = 0.001). PCR-RFLP analysis revealed 14 and 17 distinct RFLP patterns for Hha1 and Alu1 enzymes respectively. Further, RFLP analysis revealed that allele A at msp-3 alpha is more diverse in the population compared with allele B and C. Combining Hha1 and Alu1 RFLP patterns revealed 21 distinct genotypes among 22 isolates reflects higher diversity resolution power of msp-3 alpha in the field isolates. P. vivax isolates from Chennai region revealed substantial amount of genetic diversity and comparison of allelic diversity with other antigen genes and microsatellites suggesting that msp-3 alpha could be a high-resolution marker for genetic diversity studies among P. vivax field isolates.

  3. Energy and depth resolution in elastic recoil coincidence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E., E-mail: szilagyi@rmki.kfki.h [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2010-06-15

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  4. Energy and depth resolution in elastic recoil coincidence spectrometry

    International Nuclear Information System (INIS)

    Szilagyi, E.

    2010-01-01

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  5. Alpha-ray spectrometry at high temperature by using a compound semiconductor detector.

    Science.gov (United States)

    Ha, Jang Ho; Kim, Han Soo

    2013-11-01

    The use of conventional radiation detectors in harsh environments is limited by radiation damage to detector materials and by temperature constraints. We fabricated a wide-band gap semiconductor radiation detector based on silicon carbide. All the detector components were considered for an application in a high temperature environment like a nuclear reactor core. The radiation response, especially to alpha particles, was measured using an (241)Am source at variable operating voltages at room temperature in the air. The temperature on detector was controlled from 30°C to 250°C. The alpha-particle spectra were measured at zero bias operation. Even though the detector is operated at high temperature, the energy resolution as a function of temperature is almost constant within 3.5% deviation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Standard test method for the radiochemical determination of americium-241 in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method covers the determination of americium–241 in soil by means of chemical separations and alpha spectrometry. It is designed to analyze up to ten grams of soil or other sample matrices that contain up to 30 mg of combined rare earths. This method allows the determination of americium–241 concentrations from ambient levels to applicable standards. The values stated in SI units are to be regarded as standard. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see Section 10.

  7. Uranium isotopes determination in urine samples using alpha spectrometry and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Mychelle M.L.; Maihara, Vera A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Tine, Fernanda D.; Santos, Sandra M.C.; Bonifacio, Rodrigo L.; Taddei, Maria HelenaT. [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2015-07-01

    The action of determining the concentration of uranium isotopes in biological samples, 'in vitro' bioassay, is an indirect method for evaluating the incorporation and quantification of these radionuclides internally deposited. When incorporated, these radionuclides tend to be disposed through excretion, with urine being the main source of data because it can be easily collected and analyzed. The most widely used methods for determination of uranium isotopes ({sup 234}U, {sup 235}U and {sup 238}U) are Alpha Spectrometry and ICP-MS. This work presents a comparative study for the determination of uranium isotopes using these two methodologies in real samples from occupationally exposed workers. In order to validate the methodology, a sample of the intercomparison exercise organized by PROCORAD (Association pour la Promotion du Controle de Qualite des Analyses de Biologie Medicale em Radiotoxicologie) was used, and the results were statistically compared applying the Student's t-test. (author)

  8. Uranium isotopes determination in urine samples using alpha spectrometry and ICP-MS

    International Nuclear Information System (INIS)

    Rosa, Mychelle M.L.; Maihara, Vera A.; Tine, Fernanda D.; Santos, Sandra M.C.; Bonifacio, Rodrigo L.; Taddei, Maria HelenaT.

    2015-01-01

    The action of determining the concentration of uranium isotopes in biological samples, 'in vitro' bioassay, is an indirect method for evaluating the incorporation and quantification of these radionuclides internally deposited. When incorporated, these radionuclides tend to be disposed through excretion, with urine being the main source of data because it can be easily collected and analyzed. The most widely used methods for determination of uranium isotopes ( 234 U, 235 U and 238 U) are Alpha Spectrometry and ICP-MS. This work presents a comparative study for the determination of uranium isotopes using these two methodologies in real samples from occupationally exposed workers. In order to validate the methodology, a sample of the intercomparison exercise organized by PROCORAD (Association pour la Promotion du Controle de Qualite des Analyses de Biologie Medicale em Radiotoxicologie) was used, and the results were statistically compared applying the Student's t-test. (author)

  9. High resolution fast neutron spectrometry without time-of-flight

    International Nuclear Information System (INIS)

    Evans, A.E.; Brandenberger, J.D.

    1978-01-01

    Performance tests of a spectrometer tube of the type developed by Cuttler and Shalev show that the measurement of fast neutron spectra with this device can be made with an energy resolution previously obtainable only in large time-of-flight facilities. In preliminary tests, resolutions of 16.4 keV for thermal neutrons and 30.9 keV for 1-MeV neutrons were obtained. A broad-window pulse-shape discrimination (PSD) system is used to remove from pulse-height distributions most of the continua due to 3 He-recoil events, noise, and wall effect. Use of PSD improved the energy resolution to 12.9 keV for thermal neutrons and 29.2 keV for 1-MeV neutrons. The detector is a viable tool for neutron research at nominally equipped accelerator laboratories

  10. Electrospray mass spectrometry characterization of post-translational modifications of barley alpha-amylase 1 produced in yeast

    DEFF Research Database (Denmark)

    Søgaard, M; Andersen, Jens S.; Roepstorff, P

    1993-01-01

    We have used electrospray mass spectrometry (ESMS) in combination with protein chemistry and genetics to delineate post-translational modifications in yeast of barley alpha-amylase 1 (AMY1), a 45 kD enzyme crucial for production of malt, an important starting material in the manufacture of beer...

  11. Some rules to improve the energy resolution in alpha liquid scintillation with beta rejection

    CERN Document Server

    Aupiais, J; Dacheux, N

    2003-01-01

    Two common scintillating mixtures dedicated to alpha measurements by means of alpha liquid scintillation with pulse shape discrimination were tested: the di-isopropylnaphthalene - based and the toluene-based solvents containing the commercial cocktails Ultima Gold AB trademark and Alphaex trademark. We show the possibility to enhance the resolution up to 200% by using no-water miscible cocktails and by reducing the optical path. Under these conditions, the resolution of about 200 keV can be obtained either by the Tri Carb sup T sup M or by the Perals sup T sup M spectrometers. The time responses, e.g., the time required for a complete energy transfer between the initial interaction alpha particle-solvent and the final fluorescence of the organic scintillator, have been compared. Both cocktails present similar behavior. According to the Foerster theory, about 6-10 ns are required to complete the energy transfer. For both apparatus, the detection limits were determined for alpha emitters. The sensitivity of the...

  12. Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting.

    Science.gov (United States)

    Crews, Bridgit O; Pesce, Amadeo J; West, Robert; Nguyen, Hugh; Fitzgerald, Robert L

    2012-01-01

    To evaluate liquid chromatography-high-resolution mass spectrometry (LC-HR-MS) for urine toxicology screening, 29 analytes were quantitated in 152 urine specimens from patients with chronic pain using two unique mass spectrometry platforms. De-identified specimens were quantitated in April of 2011 by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) and by full-scan LC-HR-MS at Millennium Laboratories. Considering LC-MS-MS as the reference method, false positive results were identified in 19 specimens measured by LC-HR-MS. Application of relative retention times using deuterium labeled internal standards improved the rate of false positive detection to only five specimens, with four occurring for the same analyte. Ultra-high-resolution mass spectrometry (R = 100,000 at m/z 200) showed no improvement over high-resolution mass spectrometry (R = 10,000 at m/z 200) in the number of false positives detected. Quantitative results measured by LC-MS-MS and LC-HR-MS showed good agreement over four orders of dynamic range. This study demonstrates that LC-HR-MS is a suitable platform for toxicology screening for a pain management population and that quantitative accuracy and sensitivity are comparable to that achieved with LC-MS-MS. The specificity of LC-HR-MS is improved by the addition of deuterium labeled internal standards and the implementation of relative retention time matching.

  13. Determination of uranium and thorium isotopes by solid phase extraction and alpha spectrometry

    International Nuclear Information System (INIS)

    Kuruc, J.; Kovacova, M.; Strisovska, J.; Galanda, D.

    2013-01-01

    The aim of this work was to test the modified method suitable for the separation of isotopes of uranium and thorium samples of rocks, including gold ore and gold concentrate using of extraction chromatography method, after digestion of the sample, concentrating, separate the isotopes of uranium and thorium isotopes to prepare sources for the measurement of alpha spectra. Samples of rocks, gold ore and gold concentrate were digered in microwave decomposition in the environment of hydrogen peroxide and concentrated nitric acid. For the separation of uranium and thorium the vacuum box with cartridges DGA Resin and Resin(R) UTEVA (Triskem International, France) was used. Both sorbents allow separation of uranium from thorium. The results confirmed that the both sorbents give the same results within expanded uncertainty. The mass activity of monitored uranium and thorium radioisotopes was determined by alpha spectrometry method. The yields of separation were determined using uranium-232 as a tracer radionuclide; the activity of 232 U was 0.1438 Bq. Alpha spectra were measured on the Alpha spectrometer EG and G ORTEC 576A with the software MAESTRO, MCA Emulator and Gamma Vision-32 for Windows, USA. Mass activities of radionuclides were converted to mass concentration of isotopes 238 U, 234 U, 232 Th, 230 Th and 228 Th. The highest concentration of 238 U was sampled in granodiorite (Tunnel S-XIV-2, southwards, mining of Cu ore, not working there since 1990), where m( 238 U) = (0.81 ± 0.09) mg kg -1 (DGA Resin) and m( 238 U) = (0.90 ± 0.09) mg kg -1 (UTEVA(R) Resin), as well as m( 232 Th) = (18.8 ± 1.7) mg kg -1 (DGA Resin) and m( 232 Th) = (17.8 ± 1.5) mg kg -1 (UTEVA(R) Resin). In other samples of rocks, gold ore and gold concentrates have specific masses of isotopes of uranium and thorium two-to ten-folds lower. It can be concluded that the rocks, gold ores and concentrates of gold from the 'Rozalia' mine contain lower concentrations of uranium several times against

  14. Gold finger formation studied by high-resolution mass spectrometry and in silico methods

    NARCIS (Netherlands)

    Laskay, Ü.A.; Garino, C.; Tsybin, Y.O.; Salassa, L.; Casini, A.

    2015-01-01

    High-resolution mass spectrometry and quantum mechanics/molecular mechanics studies were employed for characterizing the formation of two gold finger (GF) domains from the reaction of zinc fingers (ZF) with gold complexes. The influence of both the gold oxidation state and the ZF coordination sphere

  15. Performance characteristics of high resolution semiconductor gamma ray spectrometry system

    International Nuclear Information System (INIS)

    Ko Ko Naing

    1994-05-01

    A high purity germanium (HPGe) gamma-ray detector has been used in Nuclear Research Laboratory, Department of Physics, Yangon University for over fourteen years. Now it is still being used and it is coupled to new peripheral devices, such as spectroscopy amplifier, analog to digital converter and computer fit-in S-100 multichannel analyser. Therefore, it is necessary to determine the important parameters: energy resolution, detecting efficiency and relative efficiency of the system. In the present work, these parameters were obtained by using mixed calibrated source. The results were compared to the data given by the manufacturer. Moreover, the parameters of another γ-ray detecting system NaI(T1) were also determined. In conclusion the results obtained from the above two measurements were compared and discussed

  16. Performance characteristics of high resolution semiconductor gamma ray spectrometry system

    Energy Technology Data Exchange (ETDEWEB)

    Naing, Ko Ko

    1994-05-01

    A high purity germanium (HPGe) gamma-ray detector has been used in Nuclear Research Laboratory, Department of Physics, Yangon University for over fourteen years. Now it is still being used and it is coupled to new peripheral devices, such as spectroscopy amplifier, analog to digital converter and computer fit-in S-100 multichannel analyser. Therefore, it is necessary to determine the important parameters: energy resolution, detecting efficiency and relative efficiency of the system. In the present work, these parameters were obtained by using mixed calibrated source. The results were compared to the data given by the manufacturer. Moreover, the parameters of another {gamma}-ray detecting system NaI(T1) were also determined. In conclusion the results obtained from the above two measurements were compared and discussed

  17. Use of alpha spectrometry for analysis of U-isotopes in some granite samples

    International Nuclear Information System (INIS)

    El-Galy, M.M.; Desouky, O.A.; Khattab, M.R.; Issa, F.A.

    2011-01-01

    The present study aims to use the α-spectrometry, at NMA. A radiochemical technique for analysis of U-isotopes was carried out for some granite samples from Gabal Gattar and El Missikat localities and also for some reference soil samples of IAEA. Several steps of sample preparation, radiochemical separation, and source preparation were performed before analysis. The concerned sample was leached by HNO 3 , HF and H 2 O 2 acids after ashing. The ashed sample was spiked with uranium tracer ( 232 U) for chemical yield and activity calculation. Then uranium was extracted from the matrix elements with trioctylphosphine oxide (TOPO) and stripped with 1 M NH 4 F/0.1 M HCl solution. The uranium fraction was purified by co-precipitation with LaF 3 to ensure complete removal of thorium and traces of resolution degrading elements. This was followed by a final clean-up step using an anion exchange. The pure uranium fraction was electrodeposited on a stainless steel disc from HCl/oxalate solution. The obtained results from the soil reference samples indicate general similarities between the techniques of α-spectrometers of NMA, EAEA and IAEA for analysis of U-isotopes. The U-isotopes in the granite samples of high radioactivity levels need more attempts after dilution process to be in the limit detection of α-spectrometry. (author)

  18. A sequential extraction procedure to determine Ra and U isotopes by alpha-particle spectrometry in selective leachates

    International Nuclear Information System (INIS)

    Aguado, J.L.; Bolivar, J.P.; San-Miguel, E.G.; Garcia-Tenorio, R.

    2003-01-01

    A radiochemical sequential extraction procedure has been developed in our laboratory to determine 226 Ra and 234,238 U by alpha spectrometry in environmental samples. This method has been validated for both radionuclides by comparing in selected samples the values obtained through its application with the results obtained by applying alternative procedures. Recoveries obtained, counting periods applied and background levels found in the alpha spectra give suitable detection limits to allow the Ra and U determination in operational forms defined in riverbed contaminated sediments. Results obtained in these speciation studies show that 226 Ra and 234,238 U contamination tend to be associated to precipitated forms of the sediments. (author)

  19. Electrochemistry-High Resolution Mass Spectrometry to Study Oxidation Products of Trimethoprim

    Directory of Open Access Journals (Sweden)

    Marc-André Lecours

    2018-01-01

    Full Text Available The study of the fate of emerging organic contaminants (EOCs, especially the identification of transformation products, after water treatment or in the aquatic environment, is a topic of growing interest. In recent years, electrochemistry coupled to mass spectrometry has attracted a lot of attention as an alternative technique to investigate oxidation metabolites of organic compounds. The present study used different electrochemical approaches, such as cyclic voltammetry, electrolysis, electro-assisted Fenton reaction coupled offline to high resolution mass spectrometry and thin-layer flow cell coupled online to high resolution mass spectrometry, to study oxidation products of the anti-infective trimethoprim, a contaminant of emerging concern frequently reported in wastewaters and surface waters. Results showed that mono- and di-hydroxylated derivatives of trimethoprim were generated in electrochemically and possibly tri-hydroxylated derivatives as well. Those compounds have been previously reported as mammalian and bacterial metabolites as well as transformation products of advance oxidation processes applied to waters containing trimethoprim. Therefore, this study confirmed that electrochemical techniques are relevant not only to mimic specific biotransformation reactions of organic contaminants, as it has been suggested previously, but also to study the oxidation reactions of organic contaminants of interest in water treatment. The key role that redox reactions play in the environment make electrochemistry-high resolution mass spectrometry a sensitive and simple technique to improve our understanding of the fate of organic contaminants in the environment.

  20. Bulk GaN alpha-particle detector with large depletion region and improved energy resolution

    Science.gov (United States)

    Xu, Qiang; Mulligan, Padhraic; Wang, Jinghui; Chuirazzi, William; Cao, Lei

    2017-03-01

    An alpha-particle detector was fabricated using a freestanding n-type bulk GaN wafer with a Au/Ni/GaN sandwich Schottky structure. Current-voltage measurements at room temperature revealed a Schottky contact with a leakage current of 7.53±0.3 nA at a reverse bias of 200 V. The detector had a large depletion depth that can capture much of the energy from 5.486 MeV alpha particles emitted from a 241Am source. The resolution of its alpha-particle energy spectrum was improved to 2.2±0.2% at 5.486 MeV under a bias of 550 V. This superior resolution was attributed to the shortening of the carrier transit time and the large energy deposition within the large depletion depth, i.e., 27 μm at -550 V, which all resulted in a more complete charge collection. A model developed using the ATLAS simulation framework from Silvaco Inc. was employed to study the charge collection process. The simulation results were found to agree closely with the experimental results. This detector will be beneficial for research at neutron scattering facilities, the International Thermonuclear Experimental Reactor, and the Large Hadron Collider, among other institutions, where the Si-based charged particle detectors could be quickly degraded in an intense radiation field.

  1. Determination of uranium and polonium in Spa rus aura ta by alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Luna P, M.; Renteria, M.; Montero C, M. E. [Centro de Investigacion en Materiales Avanzados, S. C., Miguel de Cervantes No. 120, Complejo Industrial Chihuahua, 31109 Chihuahua (Mexico); Manjon C, G.; Diaz, I., E-mail: elena.montero@cimav.edu.mx [Universidad de Sevilla, Escuela Tecnica Superior de Arquitectura, Departamento de Fisica Aplicada II, San Fernando No. 4, 41004 Sevilla (Spain)

    2012-06-15

    The aim of this study was optimizing conditions for the specific activities determination of some uranium-series radionuclides present in Spa rus aura ta by alpha spectrometry. Determinations of specific activities were conducted varying the type of digestion: acid attack on hot plate, controlled microwave digestion and acid attack after calcination of the sample. The latter procedure was applied only to the case of uranium isotopes determination. The variation in the isotope extraction method consisted of applying the techniques of liquid-liquid extracting using Tributyl phosphate or chromatographic UTEVA resin. Results depending on the type of treatment given to the samples were compared based on obtained chemical yields. The results reveal a higher bioaccumulation of polonium in the liver sample, with activities of 0.809, 2.495 and 2.439 Bq kg{sup -1} fresh wt compared with the fillet. The best chemical yields of polonium were close to 60% for samples that were digested by microwave. In the case of uranium the best chemical yields, close to 80% for fillet, were obtained with a previous calcination of the sample and using the UTEVA resin. (Author)

  2. Determination of uranium and polonium in Spa rus aura ta by alpha spectrometry

    International Nuclear Information System (INIS)

    Luna P, M.; Renteria, M.; Montero C, M. E.; Manjon C, G.; Diaz, I.

    2012-01-01

    The aim of this study was optimizing conditions for the specific activities determination of some uranium-series radionuclides present in Spa rus aura ta by alpha spectrometry. Determinations of specific activities were conducted varying the type of digestion: acid attack on hot plate, controlled microwave digestion and acid attack after calcination of the sample. The latter procedure was applied only to the case of uranium isotopes determination. The variation in the isotope extraction method consisted of applying the techniques of liquid-liquid extracting using Tributyl phosphate or chromatographic UTEVA resin. Results depending on the type of treatment given to the samples were compared based on obtained chemical yields. The results reveal a higher bioaccumulation of polonium in the liver sample, with activities of 0.809, 2.495 and 2.439 Bq kg -1 fresh wt compared with the fillet. The best chemical yields of polonium were close to 60% for samples that were digested by microwave. In the case of uranium the best chemical yields, close to 80% for fillet, were obtained with a previous calcination of the sample and using the UTEVA resin. (Author)

  3. Aerosols in King George Island (Antarctic peninsula) using PIXE and alpha spectrometry

    International Nuclear Information System (INIS)

    Dias da Cunha, K.; Medeiros, G.; Leal, M.A.; Lima, C.; Dalia, K.C.

    2009-01-01

    The aim of this study was to characterize the airborne particles and particles deposited in the recent snow samples collected at King George Island (Admiralty Bay) in order to evaluate the possible local sources of airborne particles and the aerosol transport from South America to Antarctic at sea level. Airborne particles samples were collected using a cascade impactor and cyclones at several sampling points at Admiralty Bay. Airborne particles were also collected during the ship travel from Rio de Janeiro to Antarctica. The recent snow samples and aerosols collected at several sampling points at Admiralty Bay were analyzed by PIXE for the determination of the elemental mass concentration. Snow samples were analyzed by alpha spectrometry to determine the 232Th, 228Th, 238U and 234U concentrations in snow. The Mass Median Aerodynamic Diameter of airborne particles was determined. The results suggest that there is a correlation between the aerosol samples and the particles deposited in the snow, but the elemental mass distributions are not equal. The snow elemental concentration can be used as an indicator of the elements present in the aerosols. The local aerosol sources (natural and anthropogenic) have been considered to characterize the aerosol transport to Antarctic, mainly King George Island. The main aerosol sources are the marine spray, weathering of local rocks and anthropogenic sources, as the diesel burning in the island. Besides the local aerosol sources the transport of airborne particles from south Atlantic to Antarctic is an important source of airborne particles at King George Island. (author)

  4. Investigation of drift gas selectivity in high resolution ion mobility spectrometry with mass spectrometry detection.

    Science.gov (United States)

    Matz, Laura M; Hill, Herbert H; Beegle, Luther W; Kanik, Isik

    2002-04-01

    Recent studies in electrospray ionization (ESI)/ion mobility spectrometry (IMS) have focussed on employing different drift gases to alter separation efficiency for some molecules. This study investigates four structurally similar classes of molecules (cocaine and metabolites, amphetamines, benzodiazepines, and small peptides) to determine the effect of structure on relative mobility changes in four drift gases (helium, nitrogen, argon, carbon dioxide). Collision cross sections were plotted against drift gas polarizability and a linear relationship was found for the nineteen compounds evaluated in the study. Based on the reduced mobility database, all nineteen compounds could be separated in one of the four drift gases, however, the drift gas that provided optimal separation was specific for the two compounds.

  5. Comparison of direct alpha spectrometry and neutron activation analysis of aerosol filters for determination of workplace thorium air concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Winkler, R. [Institut fuer Strahlenschutz, Oberschleibheim (Germany); Riedmann, W.; Weinmueller, K. [Strahlenschutz und Isotopentechnik, Muenchen (Germany)

    1996-05-01

    Direct alpha spectrometry with three different filter types was investigated for the determination of thorium air concentrations at workplaces in the manufacturing process of discharge lamps containing thoriated tungsten electrodes. The method was compared with neutron activation analysis over an activity range of five orders of magnitude. Within the experimental limits of error, both methods were found to be comparable with respect to sensitivity and accuracy. The advantage of direct alpha spectrometry, however, is that it is less laborious than neutron activation analysis and that it supplies information on the degree of radioactive equilibrium of the thorium series, which is important with regard to the estimation of dose. 20 refs., 2 figs., 1 tab.

  6. Sequential extraction procedure for determination of uranium, thorium, radium, lead and polonium radionuclides by alpha spectrometry in environmental samples

    Science.gov (United States)

    Oliveira, J. M.; Carvalho, F. P.

    2006-01-01

    A sequential extraction technique was developed and tested for common naturally-occurring radionuclides. This technique allows the extraction and purification of uranium, thorium, radium, lead, and polonium radionuclides from the same sample. Environmental materials such as water, soil, and biological samples can be analyzed for those radionuclides without matrix interferences in the quality of radioelement purification and in the radiochemical yield. The use of isotopic tracers (232U, 229Th, 224Ra, 209Po, and stable lead carrier) added to the sample in the beginning of the chemical procedure, enables an accurate control of the radiochemical yield for each radioelement. The ion extraction procedure, applied after either complete dissolution of the solid sample with mineral acids or co-precipitation of dissolved radionuclide with MnO2 for aqueous samples, includes the use of commercially available pre-packed columns from Eichrom® and ion exchange columns packed with Bio-Rad resins, in altogether three chromatography columns. All radioactive elements but one are purified and electroplated on stainless steel discs. Polonium is spontaneously plated on a silver disc. The discs are measured using high resolution silicon surface barrier detectors. 210Pb, a beta emitter, can be measured either through the beta emission of 210Bi, or stored for a few months and determined by alpha spectrometry through the in-growth of 210Po. This sequential extraction chromatography technique was tested and validated with the analysis of certified reference materials from the IAEA. Reproducibility was tested through repeated analysis of the same homogeneous material (water sample).

  7. Isotope dilution alpha spectrometry for the determination of plutonium concentration in irradiated fuel dissolver solution : IDAS and R-IDAS

    International Nuclear Information System (INIS)

    Ramaniah, M.V.; Jain, H.C.; Aggarwal, S.K.; Chitambar, S.A.; Kavimandan, V.D.; Almaula, A.I.; Shah, P.M.; Parab, A.R.; Sant, V.L.

    1980-01-01

    The report presents a new technique, Isotope Dilution Alpha Spectrometry (IDAS) and Reverse Isotope Dilution Alpha Spectrometry (R-IDAS) for determining the concentration of plutonium in the irradiated fuel dissolver solution. The method exploits sup(238)Pu in IDAS and sup(239)Pu in R-IDAS as a spike and provides an alternative method to Isotope Dilution Mass Spectrometry (IDMS) which requires enriched sup(242)Pu as a spike. Depending upon the burn-up of the fuel, sup(238)Pu or sup(239)Pu is used as a spike to change the sup(238)Pu/(sup(239)Pu+sup(240)Pu)α activity ratio in the sample by a factor of 10. This change is determined by α-spectrometry on electrodeposited sources using a solid state silicon surface barrier detector coupled to a multichannel analyser. The validity of a simple method based on the geometric progression (G.P.) decrease for the far tail of the spectrum to correct for the tail contribution of sup(238)Pu peak (5.50 MeV) to the low energy sup(239)Pu + sup(240)Pu peak (5.17 MeV) is established. Results for the plutonium concentration on different irradiated fuel dissolver solutions with burn-uo ranging from J,000 to 100,000 MWD/TU are presented and compared with those obtained by IDMS. The values obtained by IDAS or R-IDAS and IDMS agree within 0.5%. (auth.)

  8. Molecular composition of organic aerosols in central Amazonia: an ultra-high-resolution mass spectrometry study

    OpenAIRE

    Kourtchev, I; Godoi, RHM; Connors, S; Levine, JG; Archibald, AT; Godoi, AFL; Paralovo, SL; Barbosa, CGG; Souza, RAF; Manzi, AO; Seco, R; Sjostedt, S; Park, J-H; Guenther, A; Kim, S

    2016-01-01

    The Amazon Basin plays key role in atmospheric chemistry, biodiversity and climate change. In this study we applied nanoelectrospray (nanoESI) ultra-high-resolution mass spectrometry (UHRMS) for the analysis of the organic fraction of PM$_{2.5}$ aerosol samples collected during dry and wet seasons at a site in central Amazonia receiving background air masses, biomass burning and urban pollution. Comprehensive mass spectral data evaluation methods (e.g. Kendrick mass defect, Van Krevelen diagr...

  9. Study of the parabolic-spherical shape on the energy resolution in gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, Joao Carlos Pereira da

    1997-01-01

    In gamma spectrometry, the energy resolution is an important parameter. This parameter measures the capability of the system to separate two photopeaks that are together. Scintillation systems have various factors that affect the energy resolution: energy deposition, light emission, light collection and electric signal processing. Light collection depended on the mechanisms of light transport until light strikes on the photocathode. In this trajectory the light losses energy by attenuation and refractions on the surfaces. In order to minimize these effects, a parabolic-spherical shape is proposed. The energy resolutions of hemispherical and parabolic-spherical shapes were measured. The results show a better resolution for the new shape, about 33% for Compton edge due to a 137 Cs radioactive source. (author)

  10. Monte Carlo treatment planning and high-resolution alpha-track autoradiography for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zamenhof, R.G.; Lin, K.; Ziegelmiller, D.; Clement, S.; Lui, C.; Harling, O.K.

    Monte Carlo simulations of thermal neutron flux distributions in a mathematical head model have been compared to experimental measurements in a corresponding anthropomorphic gelatin-based head phantom irradiated by a thermal neutron beam as presently available at the MITR-II Research Reactor. Excellent agreement between Monte Carlo and experimental measurements has encouraged us to employ the Monte Carlo simulation technique to approach treatment planning problems in neutron capture therapy. We have also implemented a high-resolution alpha-track autoradiography technique originally developed in our laboratory at MIT. Initial autoradiograms produced by this technique meet our expectations in terms of the high resolution available and the ability to etch tracks without concommitant destruction of stained tissue. Our preliminary results with computer-aided track distribution analysis indicate that this approach is very promising in being able to quantify boron distributions in tissue at the subcellular level with a minimum amount of operator effort necessary.

  11. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Sanchez, D.P.; Sanchez, A.M.; Vargas, M.J.

    2002-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples. After adding 209 Po tracer and Pb carrier, an aliquot of the sample is decomposed by microwave digestion or by evaporation with mineral acids (depending on the expected activity of the sample). Part of the leaching solution must be used for 210 Po determination, preparing a polonium source by spontaneous deposition onto a nickel disk. The quantitative recoveries are determined using a standard 209 Po tracer, and the activity concentration is determined by isotopic dilution alpha spectrometry. The remaining part of the leaching solution is used for 210 Pb determination by means of two alternative methods: lead can be retained from 1.5 M HCl by the DOWEX 1 X 8, Cl - form resin in a chromatographic column, and stripped with deionised water, or it can be separated by solvent extraction as a lead bromide complex with the organic compound ALIQUAT-336 in toluene (this second method is used preferably in water samples). The Pb source for measurement is prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The activity concentration of 210 Pb is calculated from the spectra measured with a liquid scintillation spectrometer. Several certified material samples supplied by IAEA were analysed to check the procedure. The measured values for 210 Pb and 210 Po were in good agreement with the certified values presenting deviations lower than 5%. Several environmental samples (river and well waters and also sediments) from zones impacted by Uranium mine exploitation were analysed using the described procedure. The mean yields of Pb and Po were (70 ± 10)% and (81 ± 7)% for waters and (70 ± 12)% and (77 ± 8)% for sediments. (author)

  12. Damped Lyman-alpha absorption by disk galaxies with large redshifts. III. Intermediate-resolution spectroscopy

    International Nuclear Information System (INIS)

    Turnshek, D.A.; Wolfe, A.M.; Lanzetta, K.M.; Briggs, F.H.; Cohen, R.D.

    1989-01-01

    New intermediate-resolution spectroscopy for six members of a sample of 68 moderate- to high-redshift QSOs is presented. Evidence is reported which indicates that seven strong absorption features in the QSO spectra are due to damped Ly-alpha absorption. A standard curve-of-growth analysis on five of the damped systems is performed, and relevant properties are tabulated and discussed. Six of the seven damped Ly-alpha systems have H I column densities of 2 x 10 to the 20th/sq cm or larger, while the remaining system has an H I column density of about 10 to the 20th/sq cm. It is suggested that damped Ly-alpha systems arise when a sight line intercepts a high-redshift protogalaxy disk containing a quiescent cloud component characterized by high column density and low effective velocity dispersion. At the same time, the sight line usually intercepts a broader turbulent component, which is identified as the halo, characterized by much lower column density and higher effective velocity dispersion. 42 refs

  13. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement; Medida de los descendientes del radon en aire por Espectrometria Alfa

    Energy Technology Data Exchange (ETDEWEB)

    Acena, M L; Crespo, M T

    1989-07-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs.

  14. Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry.

    Science.gov (United States)

    Matysik, Silke; Liebisch, Gerhard

    2017-12-01

    A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Measurement of electro-sprayed 238 and 239+240 plutonium isotopes using 4π-alpha spectrometry. Application to environmental samples

    International Nuclear Information System (INIS)

    Charmoille-Roblot, M.

    1999-01-01

    A new protocol for plutonium deposition using the electro-spray technique coupled with 4π-α spectrometry is proposed to improve the detection limit, shorten the counting time. In order to increase the detection efficiency, it was proposed to measure 238 and 239+240 plutonium isotopes electro-sprayed deposit simultaneously on both sides of the source support, that must be as transparent as possible to alpha-emissions, in a two-alpha detectors chamber. A radiochemical protocol was adapted to electro-spray constraints and a very thin carbon foil was selected for 4π -alpha spectrometry. The method was applied to a batch of sediment samples and gave the same results as an electrodeposited source measured using conventional alpha spectrometry with a 25 % gain on counting time and 10 % on plutonium 238 detection limit. Validation and application of the technique have been made on reference samples. (author)

  16. Determination of 210Pb by direct gamma-ray spectrometry, beta counting via 210Bi and alpha-particle spectrometry via 210Po in coal, slag and ash samples from thermal power plant

    International Nuclear Information System (INIS)

    Seslak, Bojan; Vukanac, Ivana; Kandic, Aleksandar; Durasevic, Mirjana; Eric, Milic; Jevremovic, Aleksandar

    2017-01-01

    In order to compare three different techniques and estimate radiological impact, activity concentration of 210 Pb in coal, slag and ash samples from thermal power plant 'Nikola Tesla', Serbia, were measured, and results are presented in this study. Determination of 210 Pb was carried out in three ways: using HPGe gamma spectrometer and via in-growth of 210 Po and 210 Bi by alpha-particle spectrometry and proportional counting, respectively. The results obtained for three different techniques were compared. Statistical analysis and comparison of methods were carried out by combination of Z score and χ 2 statistical tests. Tests results, as well as values of measured activities concentrations obtained by alpha and gamma spectrometry, showed that gamma spectrometry is a valid alternative to time-consuming alpha spectrometry for low level activity measurements of 210 Pb. This remark is also valid even for gamma spectrometers with poor efficiency in low energy region. (author)

  17. Structural characterization of suppressor lipids by high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Rovillos, Mary Joy; Pauling, Josch Konstantin; Hannibal-Bach, Hans Kristian

    2016-01-01

    RATIONALE: Suppressor lipids were originally identified in 1993 and reported to encompass six lipid classes that enable Saccharomyces cerevisiae to live without sphingolipids. Structural characterization, using non-mass spectrometric approaches, revealed that these suppressor lipids are very long...... chain fatty acid (VLCFA)-containing glycerophospholipids with polar head groups that are typically incorporated into sphingolipids. Here we report, for the first time, the structural characterization of the yeast suppressor lipids using high-resolution mass spectrometry. METHODS: Suppressor lipids were...... isolated by preparative chromatography and subjected to structural characterization using hybrid quadrupole time-of-flight and ion trap-orbitrap mass spectrometry. RESULTS: Our investigation recapitulates the overall structural features of the suppressor lipids and provides an in-depth characterization...

  18. Use of the electrodeposition technique in the preparation of samples of 237Np and its determination by alpha spectrometry

    International Nuclear Information System (INIS)

    Mertzig, W.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A. de.

    1981-05-01

    The electroplating technique to prepare 237 Np source and its determination by alpha spectrometry is presented. The samples were prepared using a lucite-eletrolitic cell manufactured at IPEN, specially to trace amounts of actinides. A polished brass disk coated with Ni film has been used as cathodo and a fixed Pt wire as anode. The electroplated samples were alpha counted using a surface barrier detector. The optimum conditions to obtain the quantitative deposition of 237 Np have been achieved by studying the effects of some parameters as current density, pH and concentration of eletrolitic solution and time of eletrodeposition, using a carrier technique. After preliminary purification, the method is applied to control trace amounts of 237 Np in the Purex process solutions. (Author) [pt

  19. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  20. Determination of radium activity in some natural mineral waters using radioactive chemical extraction method and alpha spectrometry

    International Nuclear Information System (INIS)

    Nguyen Thi Oanh; Duong Van Thang; Duong Duc Thang; Nguyen Van Khanh; Doan Thuy Hau; Pham Bao Ngoc

    2017-01-01

    The 226 Ra activity concentration in several of mineral water samples of Northern Vietnam was measured by using alpha spectrometry. Ra adsorption techniques on manganese oxide were applied to produce thin alpha samples. The efficiency of sample preparation process was determined by conducting similar procedures for IAEA reference materials. The 226 Ra content in mineral water ranged from (11.33 ± 1.00) mBq/l to (38.00 ± 4.50) mBq/l. The measured maximum values do not exceed the permissible limit radiation dose for all samples (100 mBq/l - USEPA ). This study may be useful for assessing impacts of radiation dose from mineral water on human health. (author)

  1. DETERMINATION OF MUSHROOM TOXIN ALPHA-AMANITIN IN SERUM BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AFTER SOLID-PHASE EXTRACTION

    Directory of Open Access Journals (Sweden)

    Maja Vujović

    2015-03-01

    Full Text Available Alpha-amanitin is a cyclic peptide which belongs to a large group of mushroom toxins known as amatoxins. Being responsible for the majority of fatal mushroom poisonings, they require rapid detection and excretion from the body fluids. In accordance with these requirements, a simple and an accurate method was developed for successful identification and quantification of alpha-amanitin in serum with electrospray liquid chromatography–mass spectrometry (LC-ESI-MS after collision-induced dissociation. The method conforms to the established International Conference on Harmonization Q2A/Q2B 1996 guidelines on the validation of analytical methods. Linearity, precision, extraction recovery and stability test on blank serum spiked with alpha-amanitin and stored in different conditions met the acceptance criteria. The obtained calibration curve was linear over the concentration range 5-100 ng/mL with a lower limit of quantification (LOQ of 5 ng/mL and limit of detection (LOD of 2.5 ng/mL. The mean intra- and inter-day precision and accuracy were 6.05% and less than ±15% of nominal values, respectively. The neutral solid phase extraction with copolymer hydrophilic–lipophilic balance cartridges was found optimal for sample preparation with the mean recovery of 91.94%. The proposed method demonstrated high sensitivity and selectivity which can be useful both for clinical and forensic toxicology analysis of alpha-amanitin at low concentrations.

  2. Chemical vapor deposition (CVD) of uranium for alpha spectrometry; Deposicion quimica de vapor (CVD) de uranio para espectrometria alfa

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez V, M. L.; Rios M, C.; Ramirez O, J.; Davila R, J. I.; Mireles G, F., E-mail: luisalawliet@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2015-09-15

    The uranium determination through radiometric techniques as alpha spectrometry requires for its proper analysis, preparation methods of the source to analyze and procedures for the deposit of this on a surface or substrate. Given the characteristics of alpha particles (small penetration distance and great loss of energy during their journey or its interaction with the matter), is important to ensure that the prepared sources are thin, to avoid problems of self-absorption. The routine methods used for this are the cathodic electro deposition and the direct evaporation, among others. In this paper the use of technique of chemical vapor deposition (CVD) for the preparation of uranium sources is investigated; because by this, is possible to obtain thin films (much thinner than those resulting from electro deposition or evaporation) on a substrate and comprises reacting a precursor with a gas, which in turn serves as a carrier of the reaction products to achieve deposition. Preliminary results of the chemical vapor deposition of uranium are presented, synthesizing and using as precursor molecule the uranyl acetylacetonate, using oxygen as carrier gas for the deposition reaction on a glass substrate. The uranium films obtained were found suitable for alpha spectrometry. The variables taken into account were the precursor sublimation temperatures and deposition temperature, the reaction time and the type and flow of carrier gas. Of the investigated conditions, two depositions with encouraging results that can serve as reference for further work to improve the technique presented here were selected. Alpha spectra obtained for these depositions and the characterization of the representative samples by scanning electron microscopy and X-ray diffraction are also presented. (Author)

  3. Alternate method of source preparation for alpha spectrometry: No electrodeposition, no hydrofluoric acid

    International Nuclear Information System (INIS)

    Kurosaki, Hiromu; Mueller, Rebecca J.; Lambert, Susan B.; Rao, Govind R.

    2016-01-01

    An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. Lastly, it provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily.

  4. Alternate method of source preparation for alpha spectrometry: no electrodeposition, no hydrofluoric acid

    International Nuclear Information System (INIS)

    Hiromu Kurosaki; Lambert, S.B.; Rao, G.R.; Mueller, R.J.

    2017-01-01

    An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. It provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily. (author)

  5. High-resolution mass spectrometry in toxicology: current status and future perspectives.

    Science.gov (United States)

    Maurer, H H; Meyer, Markus R

    2016-09-01

    This paper reviews high-resolution mass spectrometry (HRMS) approaches using time-of-flight or Orbitrap techniques for research and application in various toxicology fields, particularly in clinical toxicology and forensic toxicology published since 2013 and referenced in PubMed. In the introduction, an overview on applications of HRMS in various toxicology fields is given with reference to current review articles. Papers concerning HRMS in metabolism, screening, and quantification of pharmaceuticals, drugs of abuse, and toxins in human body samples are critically reviewed. Finally, a discussion on advantages as well as limitations and future perspectives of these methods is included.

  6. Electrostatic ion trap and Fourier transform measurements for high-resolution mass spectrometry

    International Nuclear Information System (INIS)

    Bhushan, K. G.; Gadkari, S. C.; Yakhmi, J. V.; Sahni, V. C.

    2007-01-01

    We report on the development of an electrostatic ion trap for high-resolution mass spectrometry. The trap works on purely electrostatic fields and hence trapping and storing of ions is not mass restrictive, unlike other techniques based on Penning, Paul, or radio frequency quadrupole ion traps. It allows simultaneous trapping and studying of multiple mass species over a large mass range. Mass spectra were recorded in ''dispersive'' and ''self-bunching'' modes of ions. Storage lifetimes of about 100 ms and mass resolving power of about 20 000 could be achieved from the fifth harmonic Fourier transform spectrum of Xe ions recorded in the self-bunching mode

  7. Laboratory of High resolution gamma spectrometry; Laboratorio de espectrometria gamma de alta resolucion

    Energy Technology Data Exchange (ETDEWEB)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B

    1992-01-15

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  8. High-resolution, three-step resonance ionization mass spectrometry of gadolinium

    International Nuclear Information System (INIS)

    Blaum, K.; Wendt, K.; Bushaw, B.A.; Noertershaeuser, W.

    2001-01-01

    High-resolution resonance ionization mass spectrometry has been used to measure triple-resonance autoionization (AI) spectra of gadolinium. Al resonances as narrow as 10 MHz have been observed and isotope shifts and hyperfine structure have been measured in selected AI states. The strongest AI state observed at 49663.576 cm-1 with a photoionization cross section of >3.6x10 -15 cm 2 was found to have an overall detection efficiency of >3x10 -5 , allowing application to a number of ultratrace determination problems. Analytical measurements with a diode-laser-based system have been successfully performed on bio-medical tissue samples

  9. Characterization of Athabasca lean oil sands and mixed surficial materials: Comparison of capillary electrophoresis/low-resolution mass spectrometry and high-resolution mass spectrometry.

    Science.gov (United States)

    MacLennan, Matthew S; Peru, Kerry M; Swyngedouw, Chris; Fleming, Ian; Chen, David D Y; Headley, John V

    2018-05-15

    Oil sands mining in Alberta, Canada, requires removal and stockpiling of considerable volumes of near-surface overburden material. This overburden includes lean oil sands (LOS) which cannot be processed economically but contain sparingly soluble petroleum hydrocarbons and naphthenic acids, which can leach into environmental waters. In order to measure and track the leaching of dissolved constituents and distinguish industrially derived organics from naturally occurring organics in local waters, practical methods were developed for characterizing multiple sources of contaminated water leakage. Capillary electrophoresis/positive-ion electrospray ionization low-resolution time-of-flight mass spectrometry (CE/LRMS), high-resolution negative-ion electrospray ionization Orbitrap mass spectrometry (HRMS) and conventional gas chromatography/flame ionization detection (GC/FID) were used to characterize porewater samples collected from within Athabasca LOS and mixed surficial materials. GC/FID was used to measure total petroleum hydrocarbon and HRMS was used to measure total naphthenic acid fraction components (NAFCs). HRMS and CE/LRMS were used to characterize samples according to source. The amounts of total petroleum hydrocarbon in each sample as measured by GC/FID ranged from 0.1 to 15.1 mg/L while the amounts of NAFCs as measured by HRMS ranged from 5.3 to 82.3 mg/L. Factors analysis (FA) on HRMS data visually demonstrated clustering according to sample source and was correlated to molecular formula. LRMS coupled to capillary electrophoresis separation (CE/LRMS) provides important information on NAFC isomers by adding analyte migration time data to m/z and peak intensity. Differences in measured amounts of total petroleum hydrocarbons by GC/FID and NAFCs by HRMS indicate that the two methods provide complementary information about the nature of dissolved organic species in a soil or water leachate samples. NAFC molecule class O x S y is a possible tracer for LOS

  10. Automated, feature-based image alignment for high-resolution imaging mass spectrometry of large biological samples

    NARCIS (Netherlands)

    Broersen, A.; Liere, van R.; Altelaar, A.F.M.; Heeren, R.M.A.; McDonnell, L.A.

    2008-01-01

    High-resolution imaging mass spectrometry of large biological samples is the goal of several research groups. In mosaic imaging, the most common method, the large sample is divided into a mosaic of small areas that are then analyzed with high resolution. Here we present an automated alignment

  11. Measurements of {beta} or {alpha} emitter long lived radionuclides using inductively coupled plasma mass spectrometry; Dosage a tres bas niveau de radionucleides a longue periode emetteurs {beta} ou {alpha} par spectrometrie de masse a couplage plasma inductif

    Energy Technology Data Exchange (ETDEWEB)

    Provitina, O

    1993-10-18

    The measurement of long-lived radionuclides is highly important for characterizing nuclear wastes for their later storage. The main techniques are {alpha} spectrometry, {beta} counting and {gamma} spectrometry. The large period of these isotopes leads to low specific activity needing time consuming measurements. Moreover, the radiometric techniques are often limited by problems of interferences involving several steps of pretreatments. Among these steps, the specific extraction with crown ethers is highly selective for the separation of {sup 99}Tc, {sup 129}I and {sup 135}Cs. The radiometric techniques are here replaced by inductively coupled plasma mass spectroscopy (ICP-MS) the advantages of which are: few interferences, sensitivity which does not depend on the radiologic period as compared to radiochemistry. ICP-MS can then measure {sup 237}Np in enriched uranium matrix and reduce by a factor of 4 the sample pretreatment and the duration of the analysis usually performed by {alpha} spectrometry. Another technique, electrothermal vaporization (ETV), is consequently used. Crown ether extraction-ETV-ICP-MS is employed for measuring the long lived radionuclides {sup 99}Tc and {sup 129}I. The conditions of the extraction and the parameters of the ETV and the ICP-MS are studied and optimized. The methods optimized (extraction, electrothermal vaporization) are validated in the case of {sup 99}Tc, in real samples. The spike method is required to quantify technetium, the quantification with calibration leading to bad results. The results obtained are in good agreement with the expected values. Extraction of technetium on anionic resin and its measurement by the spike method with pneumatic nebulization-ICP-MS is also performed on other samples. Measured values are also in agreement with expected values, but the method of extraction is more time consuming (half a day) than the extraction with crown ether (one hour). (author). 54 figs., 38 tabs.

  12. [Application of liquid chromatography-high resolution mass spectrometry in toxicological screening].

    Science.gov (United States)

    Li, Xiao-Wen; Shen, Bao-Hua; Zhuo, Xian-Yi

    2011-10-01

    Due to the diversity of toxicologically relevant substances, the uncertainty of target compounds and the specificity of samples, toxicological screening techniques have always been valued by the forensic toxicologists. Depending on its powerful separation ability, superhigh resolution and accurate mass measurement, combined with the two levels spectrum database matching and abundance ratio of isotope ion, the liquid chromatography-high resolution mass spectrometry (LC-HRMS) analyzers have increasingly advantage in screening and identification of chemical compound. This review focuses on the applications of LC-HRMS in screening and identification of drug-of-abuse, prescription drugs, pesticide and stimulant. The prospect of LC-HRMS in forensic toxicology analysis is also included.

  13. Measurement of electro-sprayed 238 and 239+240 plutonium isotopes using 4{pi}-alpha spectrometry. Application to environmental samples; Spectrometrie alpha 4{pi} de sources d'actinides realisees par electronebulisation. Developpement et optimisation d'un protocole applique au mesurage des isotopes 238 et 239+240 du plutonium dans l'environnement

    Energy Technology Data Exchange (ETDEWEB)

    Charmoille-Roblot, M. [CEA/Fontenay-aux-Roses, Dept. de Protection de l' Environnement (DPRE), 92 (France)]|[Paris-11 Univ., 91 - Orsay (France)

    1999-07-01

    A new protocol for plutonium deposition using the electro-spray technique coupled with 4{pi}-{alpha} spectrometry is proposed to improve the detection limit, shorten the counting time. In order to increase the detection efficiency, it was proposed to measure 238 and 239+240 plutonium isotopes electro-sprayed deposit simultaneously on both sides of the source support, that must be as transparent as possible to alpha-emissions, in a two-alpha detectors chamber. A radiochemical protocol was adapted to electro-spray constraints and a very thin carbon foil was selected for 4{pi} -alpha spectrometry. The method was applied to a batch of sediment samples and gave the same results as an electrodeposited source measured using conventional alpha spectrometry with a 25 % gain on counting time and 10 % on plutonium 238 detection limit. Validation and application of the technique have been made on reference samples. (author)

  14. Radiochemical separation of actinides from environmental samples for determination with DF-ICP-MS and alpha spectrometry

    International Nuclear Information System (INIS)

    Ayranov, M.; Kraehenbuehl, U.; Sahli, H.; Roellin, S.; Burger, M.

    2005-01-01

    The purpose of this study was to develop an optimised sample preparation method for the determination of Pu, Am, and Cm in environmental samples, soils, and sediments, and to compare the sensitivities of DF-ICP-MS, alpha spectrometry, and liquid scintillation alpha spectrometry. Borate fusion was used for sample material digestion. Two methods based on TOPO liquid-liquid extraction and combination of TEVA and TRU extraction chromatography showed highest yields of 92.7% for Pu, 86.8% for Am, and 87.6% for Cm. The detection limits were between 0.014-0.034 Bq/kg for 239 Pu, 0.014-0.093 Bq/kg for 240 Pu, and 0.011-1.20 Bq/kg for 241 Am. Analytical results for 238 Pu, 239 Pu, 240 Pu, 241 Pu and 241 Am and their isotope ratios in certified reference materials (IAEA-135 and IAEA-300) indicated very good accuracy of the methods proposed. (orig.)

  15. Determination of {sup 236}U and transuranium elements in depleted uranium ammunition by {alpha}-spectrometry and ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Desideri, D.; Meli, M.A.; Roselli, C.; Testa, C. [General Chemistry Institute, Urbino University, Urbino (Italy); Boulyga, S.F.; Becker, J.S. [Central Department of Analytical Chemistry, Research Centre Juelich, Juelich (Germany)

    2002-11-01

    It is well known that ammunition containing depleted uranium (DU) was used by NATO during the Balkan conflict. To evaluate the origin of DU (the enrichment of natural uranium or the reprocessing of spent nuclear fuel) it is necessary to directly detect the presence of activation products ({sup 236}U, {sup 239}Pu, {sup 240}Pu, {sup 241}Am, and {sup 237}Np) in the ammunition. In this work the analysis of actinides by {alpha}-spectrometry was compared with that by inductively coupled plasma mass spectrometry (ICP-MS) after selective separation of ultratraces of transuranium elements from the uranium matrix. {sup 242}Pu and {sup 243}Am were added to calculate the chemical yield. Plutonium was separated from uranium by extraction chromatography, using tri-n-octylamine (TNOA), with a decontamination factor higher than 10{sup 6}; after elution plutonium was determined by ICP-MS ({sup 239}Pu and {sup 240}Pu) and {alpha}-spectrometry ({sup 239+240}Pu) after electroplating. The concentration of Pu in two DU penetrator samples was 7 x 10{sup -12} g g{sup -1} and 2 x 10{sup -11} g g{sup -1}. The {sup 240}Pu/{sup 239}Pu isotope ratio in one penetrator sample (0.12{+-}0.04) was significantly lower than the {sup 240}Pu/{sup 239}Pu ratios found in two soil samples from Kosovo (0.35{+-}0.10 and 0.27{+-}0.07). {sup 241}Am was separated by extraction chromatography, using di(2-ethylhexyl)phosphoric acid (HDEHP), with a decontamination factor as high as 10{sup 7}. The concentration of {sup 241}Am in the penetrator samples was 2.7 x 10{sup -14} g g{sup -1} and <9.4 x 10{sup -15} g g{sup -1}. In addition {sup 237}Np was detected at ultratrace levels. In general, ICP-MS and {alpha}-spectrometry results were in good agreement.The presence of anthropogenic radionuclides ({sup 236}U, {sup 239}Pu,{sup 240}Pu, {sup 241}Am, and {sup 237}Np) in the penetrators indicates that at least part of the uranium originated from the reprocessing of nuclear fuel. Because the concentrations of

  16. Determination of (236)U and transuranium elements in depleted uranium ammunition by alpha-spectrometry and ICP-MS.

    Science.gov (United States)

    Desideri, D; Meli, M A; Roselli, C; Testa, C; Boulyga, S F; Becker, J S

    2002-11-01

    It is well known that ammunition containing depleted uranium (DU) was used by NATO during the Balkan conflict. To evaluate the origin of DU (the enrichment of natural uranium or the reprocessing of spent nuclear fuel) it is necessary to directly detect the presence of activation products ((236)U, (239)Pu, (240)Pu, (241)Am, and (237)Np) in the ammunition. In this work the analysis of actinides by alpha-spectrometry was compared with that by inductively coupled plasma mass spectrometry (ICP-MS) after selective separation of ultratraces of transuranium elements from the uranium matrix. (242)Pu and (243)Am were added to calculate the chemical yield. Plutonium was separated from uranium by extraction chromatography, using tri- n-octylamine (TNOA), with a decontamination factor higher than 10(6); after elution plutonium was determined by ICP-MS ((239)Pu and (240)Pu) and alpha-spectrometry ((239+240)Pu) after electroplating. The concentration of Pu in two DU penetrator samples was 7 x 10(-12) g g(-1) and 2 x 10(-11) g g(-1). The (240)Pu/(239)Pu isotope ratio in one penetrator sample (0.12+/-0.04) was significantly lower than the (240)Pu/(239)Pu ratios found in two soil samples from Kosovo (0.35+/-0.10 and 0.27+/-0.07). (241)Am was separated by extraction chromatography, using di(2-ethylhexyl)phosphoric acid (HDEHP), with a decontamination factor as high as 10(7). The concentration of (241)Am in the penetrator samples was 2.7 x 10(-14) g g(-1) and <9.4 x 10(-15) g g(-1). In addition (237)Np was detected at ultratrace levels. In general, ICP-MS and alpha-spectrometry results were in good agreement. The presence of anthropogenic radionuclides ((236)U, (239)Pu,(240)Pu, (241)Am, and (237)Np) in the penetrators indicates that at least part of the uranium originated from the reprocessing of nuclear fuel. Because the concentrations of radionuclides are very low, their radiotoxicological effect is negligible.

  17. High-resolution continuum-source atomic absorption spectrometry: what can we expect?

    Directory of Open Access Journals (Sweden)

    Welz Bernhard

    2003-01-01

    Full Text Available A new instrumental concept has been developed for atomic absorption spectrometry (AAS, using a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator and a CCD array detector, providing a resolution of ~2 pm per pixel. Among the major advantages of the system are: i an improved signal-to-noise ratio because of the high intensity of the radiation source, resulting in improved photometric precision and detection limits; ii for the same reason, there are no more 'weak' lines, i.e. secondary lines can be used without compromises; iii new elements might be determined, for which no radiation source has been available; iv the entire spectral environment around the analytical line becomes 'visible', giving a lot more information than current AAS instruments; v the CCD array detector allows a truly simultaneous background correction close to the analytical line; vi the software is capable of storing reference spectra, e.g. of a molecular absorption with rotational fine structure, and of subtracting such spectra from the spectra recorded for a sample, using a least squares algorithm; vii although not yet realized, the system makes possible a truly simultaneous multi-element AAS measurement when an appropriate two-dimensional detector is used, as is already common practice in optical emission spectrometry; vii preliminary experiments have indicated that the instrumental concept could result in a more rugged analytical performance in the determination of trace elements in complex matrices.

  18. Fingerprints of flower absolutes using supercritical fluid chromatography hyphenated with high resolution mass spectrometry.

    Science.gov (United States)

    Santerre, Cyrille; Vallet, Nadine; Touboul, David

    2018-06-02

    Supercritical fluid chromatography hyphenated with high resolution mass spectrometry (SFC-HRMS) was developed for fingerprint analysis of different flower absolutes commonly used in cosmetics field, especially in perfumes. Supercritical fluid chromatography-atmospheric pressure photoionization-high resolution mass spectrometry (SFC-APPI-HRMS) technique was employed to identify the components of the fingerprint. The samples were separated with a porous graphitic carbon (PGC) Hypercarb™ column (100 mm × 2.1 mm, 3 μm) by gradient elution using supercritical CO 2 and ethanol (0.0-20.0 min (2-30% B), 20.0-25.0 min (30% B), 25.0-26.0 min (30-2% B) and 26.0-30.0 min (2% B)) as mobile phase at a flow rate of 1.5 mL/min. In order to compare the SFC fingerprints between five different flower absolutes: Jasminum grandiflorum absolutes, Jasminum sambac absolutes, Narcissus jonquilla absolutes, Narcissus poeticus absolutes, Lavandula angustifolia absolutes from different suppliers and batches, the chemometric procedure including principal component analysis (PCA) was applied to classify the samples according to their genus and their species. Consistent results were obtained to show that samples could be successfully discriminated. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, D.; Imme, G.; Catalano, R. [Dipartimento di Fisica e Astronomia, Universita degli Studi di Catania, via S. Sofia, 64- 95123 Catania (Italy); Istituto Nazionale di Fisica Nucleare - Sezione di Catania, via S. Sofia, 64- 95123 Catania (Italy); Aranzulla, M. [Istituto Nazionale Geofisica e Vulcanologia - Sezione di Catania, piazza Roma, 2- 95127 Catania (Italy); Tazzer, A. L. Rosselli; Mangano, G. [Dipartimento di Fisica e Astronomia, Universita degli Studi di Catania, via S. Sofia, 64- 95123 Catania (Italy)

    2011-12-13

    Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected to a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.

  20. High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification

    Energy Technology Data Exchange (ETDEWEB)

    David L. Chichester; James T. Johnson; Edward H. Seabury

    2012-07-01

    Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations

  1. Resolution of G(s)alpha and G(q)alpha/G(11)alpha proteins in membrane domains by two-dimensional electrophoresis: the effect of long-term agonist stimulation.

    Science.gov (United States)

    Matousek, P; Novotný, J; Svoboda, P

    2004-01-01

    Low-density membrane-domain fractions were prepared from S49 lymphoma cells and clone e2m11 of HEK293 cells expressing a large number of thyrotropin-releasing hormone receptor (TRH-R) and G(11)alpha by flotation on sucrose density gradients. The intact cell structure was broken by detergent-extraction, alkaline-treatment or drastic homogenization. Three types of low-density membranes were resolved by two-dimensional electrophoresis and analyzed for G(s)alpha (S49) or G(q)alpha/G11) (e2m11) content. Four individual immunoblot signals of Gsalpha protein were identified in S49 lymphoma cells indicating complete resolution of the long G(s)alpha L+/-ser and short G(s)alpha S+/-ser variants of G(s)alpha. All these were diminished by prolonged agonist (isoprenaline) stimulation. In e2m11-HEK cells, five different immunoblot signals were detected indicating post-translational modification of G proteins of G(q)alpha/G(11)alpha family. The two major spots corresponding to exogenously (over)expressed G(11)alpha and endogenous G(q)alpha were reduced; the minor spots diminished by hormonal stimulation. Parallel analysis by silver staining of the total protein content indicated that no major changes in protein composition occurred under these conditions. Our data thus indicate that agonist-stimulation of target cells results in down-regulation of all different members of G(s) and G(q)/G(11) families. This agonist-specific effect may be demonstrated in crude membrane as well as domain/raft preparations and it is not accompanied by changes in overall protein composition.

  2. Profiling of integral membrane proteins and their post translational modifications using high-resolution mass spectrometry

    Science.gov (United States)

    Souda, Puneet; Ryan, Christopher M.; Cramer, William A.; Whitelegge, Julian

    2011-01-01

    Integral membrane proteins pose challenges to traditional proteomics approaches due to unique physicochemical properties including hydrophobic transmembrane domains that limit solubility in aqueous solvents. A well resolved intact protein molecular mass profile defines a protein’s native covalent state including post-translational modifications, and is thus a vital measurement toward full structure determination. Both soluble loop regions and transmembrane regions potentially contain post-translational modifications that must be characterized if the covalent primary structure of a membrane protein is to be defined. This goal has been achieved using electrospray-ionization mass spectrometry (ESI-MS) with low-resolution mass analyzers for intact protein profiling, and high-resolution instruments for top-down experiments, toward complete covalent primary structure information. In top-down, the intact protein profile is supplemented by gas-phase fragmentation of the intact protein, including its transmembrane regions, using collisionally activated and/or electroncapture dissociation (CAD/ECD) to yield sequence-dependent high-resolution MS information. Dedicated liquid chromatography systems with aqueous/organic solvent mixtures were developed allowing us to demonstrate that polytopic integral membrane proteins are amenable to ESI-MS analysis, including top-down measurements. Covalent post-translational modifications are localized regardless of their position in transmembrane domains. Top-down measurements provide a more detail oriented high-resolution description of post-transcriptional and post-translational diversity for enhanced understanding beyond genomic translation. PMID:21982782

  3. Determination of radium and uranium isotopes in natural waters by sorption on hydrous manganese dioxide followed by alpha-spectrometry

    International Nuclear Information System (INIS)

    Bojanowski, R.; Radecki, Z.; Burns, K.

    2005-01-01

    Water samples, spiked with 133 Ba and 232 U radiotracers, are scavenged for radium and uranium isotopes using hydrous manganese dioxide which is produced in-situ, by reacting manganese (+2) and permanganate ions at pH 8-9. The precipitate is solubilized with ascorbic and acetic acids and the resulting solution filtered through a glass fibre filter GF/F to remove particulate matter. The radium is co-precipitated with barium ions by the addition of a saturated Na 2 SO 4 solution where a small amount of BaSO 4 suspension is introduced to initiate crystallization. The micro precipitate containing the radium is collected on a 0.1 membrane filter and the filtrate saved for follow-up uranium analysis. The 226 Ra on the filter is determined by alpha-spectrometry and its recovery is assessed by measuring the 133 Ba on the same filter using gamma-spectrometry. The filtrate containing uranium is passed through a Dowex AG 1 x 4 ion-exchange resin in the SO 4 2- form which retains uranium while other ions are eluted by dilute (0.25M) sulphuric acid. Uranium is eluted from the column by distilled water, electrodeposited on a silver disc and the uranium isotopes and their recovery are determined by alpha-spectrometry. The method was tested on a variety of natural and spiked water samples with known concentrations of 226 Ra and 238 U and was found to yield accurate results within ±10% RSD of the target values. (author)

  4. Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo

    OpenAIRE

    Boulyga, S. F.; Testa, C.; Desideri, D.; Becker, J. S.

    2001-01-01

    The determination of environmental contamination with natural and artificial actinide isotopes and evaluation of their source requires precise isotopic determination of actinides, above all uranium and plutonium. This can be achieved by alpha spectrometry or by inductively coupled plasma mass spectrometry (ICP-MS) after chemical separation of actinides. The performance of a sector-field ICP-MS (ICP-SFMS) coupled to a low-flow micronebulizer with a membrane desolvation unit, "Aridus'', was stu...

  5. Auditory conflict resolution correlates with medial-lateral frontal theta/alpha phase synchrony.

    Science.gov (United States)

    Huang, Samantha; Rossi, Stephanie; Hämäläinen, Matti; Ahveninen, Jyrki

    2014-01-01

    When multiple persons speak simultaneously, it may be difficult for the listener to direct attention to correct sound objects among conflicting ones. This could occur, for example, in an emergency situation in which one hears conflicting instructions and the loudest, instead of the wisest, voice prevails. Here, we used cortically-constrained oscillatory MEG/EEG estimates to examine how different brain regions, including caudal anterior cingulate (cACC) and dorsolateral prefrontal cortices (DLPFC), work together to resolve these kinds of auditory conflicts. During an auditory flanker interference task, subjects were presented with sound patterns consisting of three different voices, from three different directions (45° left, straight ahead, 45° right), sounding out either the letters "A" or "O". They were asked to discriminate which sound was presented centrally and ignore the flanking distracters that were phonetically either congruent (50%) or incongruent (50%) with the target. Our cortical MEG/EEG oscillatory estimates demonstrated a direct relationship between performance and brain activity, showing that efficient conflict resolution, as measured with reduced conflict-induced RT lags, is predicted by theta/alpha phase coupling between cACC and right lateral frontal cortex regions intersecting the right frontal eye fields (FEF) and DLPFC, as well as by increased pre-stimulus gamma (60-110 Hz) power in the left inferior fontal cortex. Notably, cACC connectivity patterns that correlated with behavioral conflict-resolution measures were found during both the pre-stimulus and the pre-response periods. Our data provide evidence that, instead of being only transiently activated upon conflict detection, cACC is involved in sustained engagement of attentional resources required for effective sound object selection performance.

  6. Auditory Conflict Resolution Correlates with Medial–Lateral Frontal Theta/Alpha Phase Synchrony

    Science.gov (United States)

    Huang, Samantha; Rossi, Stephanie; Hämäläinen, Matti; Ahveninen, Jyrki

    2014-01-01

    When multiple persons speak simultaneously, it may be difficult for the listener to direct attention to correct sound objects among conflicting ones. This could occur, for example, in an emergency situation in which one hears conflicting instructions and the loudest, instead of the wisest, voice prevails. Here, we used cortically-constrained oscillatory MEG/EEG estimates to examine how different brain regions, including caudal anterior cingulate (cACC) and dorsolateral prefrontal cortices (DLPFC), work together to resolve these kinds of auditory conflicts. During an auditory flanker interference task, subjects were presented with sound patterns consisting of three different voices, from three different directions (45° left, straight ahead, 45° right), sounding out either the letters “A” or “O”. They were asked to discriminate which sound was presented centrally and ignore the flanking distracters that were phonetically either congruent (50%) or incongruent (50%) with the target. Our cortical MEG/EEG oscillatory estimates demonstrated a direct relationship between performance and brain activity, showing that efficient conflict resolution, as measured with reduced conflict-induced RT lags, is predicted by theta/alpha phase coupling between cACC and right lateral frontal cortex regions intersecting the right frontal eye fields (FEF) and DLPFC, as well as by increased pre-stimulus gamma (60–110 Hz) power in the left inferior fontal cortex. Notably, cACC connectivity patterns that correlated with behavioral conflict-resolution measures were found during both the pre-stimulus and the pre-response periods. Our data provide evidence that, instead of being only transiently activated upon conflict detection, cACC is involved in sustained engagement of attentional resources required for effective sound object selection performance. PMID:25343503

  7. Auditory conflict resolution correlates with medial-lateral frontal theta/alpha phase synchrony.

    Directory of Open Access Journals (Sweden)

    Samantha Huang

    Full Text Available When multiple persons speak simultaneously, it may be difficult for the listener to direct attention to correct sound objects among conflicting ones. This could occur, for example, in an emergency situation in which one hears conflicting instructions and the loudest, instead of the wisest, voice prevails. Here, we used cortically-constrained oscillatory MEG/EEG estimates to examine how different brain regions, including caudal anterior cingulate (cACC and dorsolateral prefrontal cortices (DLPFC, work together to resolve these kinds of auditory conflicts. During an auditory flanker interference task, subjects were presented with sound patterns consisting of three different voices, from three different directions (45° left, straight ahead, 45° right, sounding out either the letters "A" or "O". They were asked to discriminate which sound was presented centrally and ignore the flanking distracters that were phonetically either congruent (50% or incongruent (50% with the target. Our cortical MEG/EEG oscillatory estimates demonstrated a direct relationship between performance and brain activity, showing that efficient conflict resolution, as measured with reduced conflict-induced RT lags, is predicted by theta/alpha phase coupling between cACC and right lateral frontal cortex regions intersecting the right frontal eye fields (FEF and DLPFC, as well as by increased pre-stimulus gamma (60-110 Hz power in the left inferior fontal cortex. Notably, cACC connectivity patterns that correlated with behavioral conflict-resolution measures were found during both the pre-stimulus and the pre-response periods. Our data provide evidence that, instead of being only transiently activated upon conflict detection, cACC is involved in sustained engagement of attentional resources required for effective sound object selection performance.

  8. Current use of high-resolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control.

    Science.gov (United States)

    Ojanperä, Ilkka; Kolmonen, Marjo; Pelander, Anna

    2012-05-01

    Clinical and forensic toxicology and doping control deal with hundreds or thousands of drugs that may cause poisoning or are abused, are illicit, or are prohibited in sports. Rapid and reliable screening for all these compounds of different chemical and pharmaceutical nature, preferably in a single analytical method, is a substantial effort for analytical toxicologists. Combined chromatography-mass spectrometry techniques with standardised reference libraries have been most commonly used for the purpose. In the last ten years, the focus has shifted from gas chromatography-mass spectrometry to liquid chromatography-mass spectrometry, because of progress in instrument technology and partly because of the polarity and low volatility of many new relevant substances. High-resolution mass spectrometry (HRMS), which enables accurate mass measurement at high resolving power, has recently evolved to the stage that is rapidly causing a shift from unit-resolution, quadrupole-dominated instrumentation. The main HRMS techniques today are time-of-flight mass spectrometry and Orbitrap Fourier-transform mass spectrometry. Both techniques enable a range of different drug-screening strategies that essentially rely on measuring a compound's or a fragment's mass with sufficiently high accuracy that its elemental composition can be determined directly. Accurate mass and isotopic pattern acts as a filter for confirming the identity of a compound or even identification of an unknown. High mass resolution is essential for improving confidence in accurate mass results in the analysis of complex biological samples. This review discusses recent applications of HRMS in analytical toxicology.

  9. Alpha-spectrometry and fractal analysis of surface micro-images for characterisation of porous materials used in manufacture of targets for laser plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Aushev, A A; Barinov, S P; Vasin, M G; Drozdov, Yu M; Ignat' ev, Yu V; Izgorodin, V M; Kovshov, D K; Lakhtikov, A E; Lukovkina, D D; Markelov, V V; Morovov, A P; Shishlov, V V [Russian Federal Nuclear Center ' All-Russian Research Institute of Experimental Physics' , Sarov, Nizhnii Novgorod region (Russian Federation)

    2015-06-30

    We present the results of employing the alpha-spectrometry method to determine the characteristics of porous materials used in targets for laser plasma experiments. It is shown that the energy spectrum of alpha-particles, after their passage through porous samples, allows one to determine the distribution of their path length in the foam skeleton. We describe the procedure of deriving such a distribution, excluding both the distribution broadening due to statistical nature of the alpha-particle interaction with an atomic structure (straggling) and hardware effects. The fractal analysis of micro-images is applied to the same porous surface samples that have been studied by alpha-spectrometry. The fractal dimension and size distribution of the number of the foam skeleton grains are obtained. Using the data obtained, a distribution of the total foam skeleton thickness along a chosen direction is constructed. It roughly coincides with the path length distribution of alpha-particles within a range of larger path lengths. It is concluded that the combined use of the alpha-spectrometry method and fractal analysis of images will make it possible to determine the size distribution of foam skeleton grains (or pores). The results can be used as initial data in theoretical studies on propagation of the laser and X-ray radiation in specific porous samples. (laser plasma)

  10. HPGe detectors long time behaviour in high-resolution γ spectrometry

    International Nuclear Information System (INIS)

    Sajo-Bohus, L.; Rosso, D.; Sajo Castelli, A.M.; Napoli, D.R.; Fioretto, E.; Menegazzo, R.; Barros, H.; Ur, C.A.; Palacios, D.; Liendo, J.

    2011-01-01

    A large set of data on long term performance of n-type HPGe detectors used in GASP, EUROBALL and CLARA γ spectrometers, as well as environmental measurements have been collected over two decades. In this paper a detailed statistical analysis of this data is given and detector long term behaviour is provided to the scientific community. We include failure, failure mode, repair frequency, repair outcome and its influence in the energy efficiency and energy resolution. A remarkable result is that the life span distribution is exponential. A detector's failure is a memory-less process, where a previous failure does not influence the upcoming one. Repaired spectrometers result in high reliability with deep implications in the management of large scale high-resolution gamma spectrometry related projects. Findings show that on average, detectors initial counting efficiency is slightly lower (∼2%) than that reported by the manufacturers and the repair process (including annealing) does not affect significantly the energy efficiency, even after a long period of use. Repaired detector energy resolution statistics show that the probability, that a repaired detector will be at least as good as it was originally, is more than 3/4.

  11. In-depth glycoproteomic characterization of γ-conglutin by high-resolution accurate mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Silvia Schiarea

    Full Text Available The molecular characterization of bioactive food components is necessary for understanding the mechanisms of their beneficial or detrimental effects on human health. This study focused on γ-conglutin, a well-known lupin seed N-glycoprotein with health-promoting properties and controversial allergenic potential. Given the importance of N-glycosylation for the functional and structural characteristics of proteins, we studied the purified protein by a mass spectrometry-based glycoproteomic approach able to identify the structure, micro-heterogeneity and attachment site of the bound N-glycan(s, and to provide extensive coverage of the protein sequence. The peptide/N-glycopeptide mixtures generated by enzymatic digestion (with or without N-deglycosylation were analyzed by high-resolution accurate mass liquid chromatography-multi-stage mass spectrometry. The four main micro-heterogeneous variants of the single N-glycan bound to γ-conglutin were identified as Man2(Xyl (Fuc GlcNAc2, Man3(Xyl (Fuc GlcNAc2, GlcNAcMan3(Xyl (Fuc GlcNAc2 and GlcNAc 2Man3(Xyl (Fuc GlcNAc2. These carry both core β1,2-xylose and core α1-3-fucose (well known Cross-Reactive Carbohydrate Determinants, but corresponding fucose-free variants were also identified as minor components. The N-glycan was proven to reside on Asn131, one of the two potential N-glycosylation sites. The extensive coverage of the γ-conglutin amino acid sequence suggested three alternative N-termini of the small subunit, that were later confirmed by direct-infusion Orbitrap mass spectrometry analysis of the intact subunit.

  12. Comparison of the analytical methods used to determine natural and artificial radionuclides from environmental samples by gamma, alpha and beta spectrometry

    DEFF Research Database (Denmark)

    Pöllänen, Roy; Virtanen, Sinikka; Kämäräinen, Meerit

    In CAMNAR, an extensive interlaboratory exercise on the analytical methods used to determine several radionuclides present in the environmental samples was organized. Activity concentration of different natural radionuclides, such as Rn-222, Pb-210, Po-210, K-40, Ra-226, Ra-228 and isotopes...... of uranium, in addition to artificial Cs-137 and Am-241 were analysed from lake sediment samples and drinking water. The measurement techniques were gamma-ray spectrometry, alpha spectrometry, liquid scintillation counting and inductively coupled plasma mass spectrometry. Twenty six laboratories from nine...

  13. Resolution function normalisation and secondary extinction in neutron triple-axis spectrometry

    International Nuclear Information System (INIS)

    Tindle, G.L.

    1987-01-01

    The theory of resolution correction in triple-axis spectrometry is developed from first principles. It is demonstrated that for ideally imperfect thin crystals the formulation coincides with that introduced initially by Cooper and Nathans and subsequently considered by Dorner. The predicted energy variation of peak Bragg reflectivities of monochromator and analyser crystals in Bragg case scattering is such as to confirm experimental data. In the Laue case to obtain results compatible with experiment one has to invoke theories of secondary extinction. In an attempt to accommodate these observations a new finite threshold model of secondary extinction is proposed which interpolates thin crystals formulas and conventional secondary extinction formulas obtained in the zero threshold limit. (orig.)

  14. The application of computer technique in routine neutron activation analysis using high resolution gamma ray spectrometry

    International Nuclear Information System (INIS)

    Szopa, Z.; Plejewska, M.; Staszelis, J.

    1982-01-01

    A full system of four computer programs for routine - qualitative and quantitative - neutron activation analysis (NAA) using high resolution gamma ray-spectrometry had been elaborated. The structure and possibilities of the ''data flow'' programs i.e. programs DIDPDP and DIDCDC, dedicated for fast and reliable ''off line'' data transfer between the buffer memory of the spectrometric line (9-track magnetic tape) and the fast access memory (disc) of the used computers PDP-11/45 and CYBER-73 had been presented. The structure and organization of the ''data processing'' programs i.e. programs SAWAPS and MAZYG had been presented as well. The utility and reliability of these programs in the case of the large-scale, routine NAA, exampled by analysis of filters with air polutants, had been tested and discussed. Programs are written mainly in FORTRAN. (author)

  15. Determination of Pu isotopic composition and 241Am by high resolution gamma spectrometry on solid samples

    International Nuclear Information System (INIS)

    Sarkar, Arnab; Paul, Sumana; Aggarwal, Suresh K.; Tomar, Bhupendra S.

    2011-08-01

    The present report gives a detailed account of the development of non-destructive assay technique using high resolution gamma-ray spectrometry (HRGS) for determination of plutonium (Pu) isotopic composition and the 241 Am content in solid Pu samples. Energy range 120-420 keV was used in this study. The methodology involves in situ relative efficiency calibration during the measurement process itself, to reduce the errors and increase the reliability of the method. Twenty solid Pu samples of power reactor and research reactor grade were analyzed by this method and the results were compared with those obtained by thermal ionization mass spectrometry. The accuracy of the final results depends strongly upon the accuracy of the available nuclear data (decay constant, gamma abundance etc.). MATLAB based programme was written to perform the analysis. A counting time of 4 hour was chosen for achieving good statistics on the results for samples having 100-200 mg of Pu. The attainable accuracy is found to be 0.5-1% for the fissile isotopes ( 239 Pu + 241 Pu) and 5-10% for 241 Am content. (author)

  16. Rapid method for the sequential measurement of isotopes of Am and Pu in liquid matrices by alpha spectrometry

    International Nuclear Information System (INIS)

    Mantero Cabrera, J.

    2014-01-01

    : In radiological emergencies it's necessary a fast response from the laboratories in the quantification of certain radionuclides, in order to take decisions. In these cases, is the reaction time the key parameter to consider (without neglecting the quality of the measurement). In this work, it is shown a method for aqueous matrices that generates Pu and Am isotopes sources in one single day of work, to be measured subsequently by alpha spectrometry. The developed methodology has been validated through its application to reference samples and also taking part intercom- parison exercises, having in both cases, satisfactory results. This way, we check the validity of this fast method that let us generate in 24 hours (since the sample arrives our laboratory), one measurement with a Minimun Detectable Activity (MDA) of about 0.004Bq/L for Pu and Am isotopes in liquid matrices. [es

  17. Application of alpha spectrometry to the discovery of new elements by heavy-ion-beam bombardment

    International Nuclear Information System (INIS)

    Nitschke, J.M.

    1983-05-01

    Starting with polonium in 1898, α-spectrometry has played a decisive role in the discovery of new, heavy elements. For even-even nuclei, α-spectra have proved simple to interpret and exhibit systematic trends that allow extrapolation to unknown isotopes. The early discovery of the natural α-decay series led to the very powerful method of genetically linking the decay of new elements to the well-established α-emission of daughter and granddaughter nuclei. This technique has been used for all recent discoveries of new elements including Z = 109. Up to mendelevium (Z = 101), thin samples suitable for α-spectrometry were prepared by chemical methods. With the advent of heavy-ion accelerators new sample preparation methods emerged. These were based on the large momentum transfer associated with heavy-ion reactions, which produced energetic target recoils that, when ejected from the target, could be thermalized in He gas. Subsequent electrical deposition or a He-jet technique yielded samples that were not only thin enough for α-spectroscopy, but also for α- and #betta#-recoil experiments. Many variations of these methods have been developed and are discussed. For the synthesis of element 106 an aerosol-based recoil transport technique was devised. In the most recent experiments, α-spectrometry has been coupled with the magnetic analysis of the recoils. The time from production to analysis of an isotope has thereby been reduced to 10 - 6 s; while it was 10 - 1 to 10 0 s for He-jets and 10 1 to 10 3 s for rapid chemical separations. Experiments are now in progress to synthesize super heavy elements (SHE) and to analyze them with these latest techniques. Again, α-spectrometry will play a major role since the expected signature for the decay of a SHE is a sequence of α-decays followed by spontaneous fission

  18. Measurement of airborne concentrations of radon-220 daughter products by alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Kerr, G.D.; Ryan, M.T.; Perdue, P.T.

    1978-01-01

    The decay of naturally occurring uranium-238 and thorium-232 produces radon-222 and radon-220 isotopes which can escape into the atmosphere. If these radon gases become concentrated in air, their daughter products may present an inhalation hazard to man. The airborne concentrations of radon-222 can usually be measured very accurately in the presence of normal airborne concentrations of radon-220 and its daughters. In contrast, the measurements of the airborne concentrations of radon-220 daughters are usually complicated by the presence of radon-222 and its daughters even at normally occurring airborne concentrations. The complications involved in these measurements can be overcome in most situations by using an alpha particle spectrometer to distinguish the activity of radon-222 daughters from that due to radon-220 daughters collected on a filter. A practical spectrometer for field measurements of alpha particle activity on a filter is discussed

  19. Part 1: determination of radioactive disequilibrium in uranium ores by alpha-spectrometry

    International Nuclear Information System (INIS)

    Killeen, P.G.; Carmichael, C.M.

    1976-01-01

    An α-spectrometric method of detecting the presence of disequilibrium in the 238 U decay series has been developed. A silicon semi-conductor detector and a 1024 channel pulse height analyzer were used to obtain alpha particle energy spectra of uraniferous rocks and minerals. 'Infinitely thick' sources were used to avoid the problems involved in preparation of 'infinitely thin' sources. The method involves the generation of theoretical energy distributions for infinitely thick sources. Complete theoretical spectra were computed for comparison with experimentally obtained alpha particle energy spectra of rocks and minerals. The presence and extent of disequilibrium in the 238 U decay series in a rock is determined from the residual spectrum obtained by subtracting a fitted theoretical spectrum from the measured spectrum of a rock. (author)

  20. An experimental study of symmetric and asymmetric peak-fitting parameters for alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Martin Sanchez, A.; Vera Tome, F.; Caceres Marzal, D.; Bland, C.J.

    1994-01-01

    A pulse-height spectrum of alpha-particle emissions at discrete energies can be fitted by the peak-shape functions generated by combining asymmetric truncated exponential functions with a symmetric Gaussian distribution. These functions have been applied successfully by several workers. A correlation was previously found between the variance of the symmetric Gaussian portion of the fitting function, and the parameter characterising the principal exponential tailing function. The results of a more detailed experimental study are reported, which involve varying the angle and the distance between the source and the detector. This analysis shows that the parameters of the symmetric and asymmetric parts of the fitted functions seem to depend on either the detector or the source. These parameters are influenced by the energy loss suffered by the alpha-particles as well as by the efficiency of charge collection in the solid-state detector. (orig.)

  1. Thorium: one of the analytical techniques in neutronic activation and alpha spectrometry of the CDTN (Brazilian Nuclear Technology Development Center) in the last three decades

    International Nuclear Information System (INIS)

    Menezes, M.A.B.C.; Sabino, C.V.S.

    1994-01-01

    For long years, the CDTN (Brazilian Nuclear Technology Development Center ) has applied several analytical techniques in the thorium determination. This work is about the evolution of the neutronic activation in the thorium 232 analysis from the 1960's to now. The importance of the analysis request and alpha spectrometry for the thorium 228 and thorium 232 determination is emphasized. (J.A.M.M.)

  2. The 2.0-A resolution structure of soybean beta-amylase complexed with alpha-cyclodextrin.

    Science.gov (United States)

    Mikami, B; Hehre, E J; Sato, M; Katsube, Y; Hirose, M; Morita, Y; Sacchettini, J C

    1993-07-13

    New crystallographic findings are presented which offer a deeper understanding of the structure and functioning of beta-amylase, the first known exo-type starch-hydrolyzing enzyme. A refined three-dimensional structure of soybean beta-amylase, complexed with the inhibitor alpha-cyclodextrin, has been determined at 2.0-A resolution with a conventional R-value of 17.5%. The model contains 491 amino acid residues, 319 water molecules, 1 sulfate ion, and 1 alpha-cyclodextrin molecule. The protein consists of a core with an (alpha/beta)8 supersecondary structure, plus a smaller globular region formed by long loops (L3, L4, and L5) extending from beta-strands beta 3, beta 4, and beta 5. Between the two regions is a cleft that opens into a pocket whose floor contains the postulated catalytic center near the carboxyl group of Glu 186. The annular alpha-cyclodextrin binds in (and partly projects from) the cleft with its glucosyl O-2/O-3 face abutting the (alpha/beta)8 side and with its alpha-D(1 --> 4) glucosidic linkage progression running clockwise as viewed from that side. The ligand does not bind deeply enough to interact with the carboxyl group of Glu 186. Rather, it occupies most of the cleft entrance, strongly suggesting that alpha-cyclodextrin inhibits catalysis by blocking substrate access to the more deeply located reaction center. Of the various alpha-cyclodextrin interactions with protein residues in loops L4, L5, L6, and L7, most notable is the shallow inclusion complex formed with Leu 383 (in L7, on the core side of the cleft) through contacts of its methyl groups with the C-3 atoms of four of the ligand's D-glucopyranosyl residues. All six residues of the bound alpha-cyclodextrin are of 4C1 conformation and are joined by alpha-1,4 linkages with similar torsional angles to form a nearly symmetrical torus as reported for crystalline inclusion complexes with alpha-cyclodextrin. We envision a significant role for the methyl groups of Leu 383 at the cleft entrance

  3. Indexing Permafrost Soil Organic Matter Degradation Using High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Mann, Benjamin F; Chen, Hongmei; Herndon, Elizabeth M; Chu, Rosalie K; Tolic, Nikola; Portier, Evan F; Roy Chowdhury, Taniya; Robinson, Errol W; Callister, Stephen J; Wullschleger, Stan D; Graham, David E; Liang, Liyuan; Gu, Baohua

    2015-01-01

    Microbial degradation of soil organic matter (SOM) is a key process for terrestrial carbon cycling, although the molecular details of these transformations remain unclear. This study reports the application of ultrahigh resolution mass spectrometry to profile the molecular composition of SOM and its degradation during a simulated warming experiment. A soil sample, collected near Barrow, Alaska, USA, was subjected to a 40-day incubation under anoxic conditions and analyzed before and after the incubation to determine changes of SOM composition. A CHO index based on molecular C, H, and O data was utilized to codify SOM components according to their observed degradation potentials. Compounds with a CHO index score between -1 and 0 in a water-soluble fraction (WSF) demonstrated high degradation potential, with a highest shift of CHO index occurred in the N-containing group of compounds, while similar stoichiometries in a base-soluble fraction (BSF) did not. Additionally, compared with the classical H:C vs O:C van Krevelen diagram, CHO index allowed for direct visualization of the distribution of heteroatoms such as N in the identified SOM compounds. We demonstrate that CHO index is useful not only in characterizing arctic SOM at the molecular level but also enabling quantitative description of SOM degradation, thereby facilitating incorporation of the high resolution MS datasets to future mechanistic models of SOM degradation and prediction of greenhouse gas emissions.

  4. Strategies for dereplication of natural compounds using high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Kind, Tobias; Fiehn, Oliver

    2017-09-01

    Complete structural elucidation of natural products is commonly performed by nuclear magnetic resonance spectroscopy (NMR), but annotating compounds to most likely structures using high-resolution tandem mass spectrometry is a faster and feasible first step. The CASMI contest 2016 (Critical Assessment of Small Molecule Identification) provided spectra of eighteen compounds for the best manual structure identification in the natural products category. High resolution precursor and tandem mass spectra (MS/MS) were available to characterize the compounds. We used the Seven Golden Rules, Sirius2 and MS-FINDER software for determination of molecular formulas, and then we queried the formulas in different natural product databases including DNP, UNPD, ChemSpider and REAXYS to obtain molecular structures. We used different in-silico fragmentation tools including CFM-ID, CSI:FingerID and MS-FINDER to rank these compounds. Additional neutral losses and product ion peaks were manually investigated. This manual and time consuming approach allowed for the correct dereplication of thirteen of the eighteen natural products.

  5. A new processing scheme for ultra-high resolution direct infusion mass spectrometry data

    Science.gov (United States)

    Zielinski, Arthur T.; Kourtchev, Ivan; Bortolini, Claudio; Fuller, Stephen J.; Giorio, Chiara; Popoola, Olalekan A. M.; Bogialli, Sara; Tapparo, Andrea; Jones, Roderic L.; Kalberer, Markus

    2018-04-01

    High resolution, high accuracy mass spectrometry is widely used to characterise environmental or biological samples with highly complex composition enabling the identification of chemical composition of often unknown compounds. Despite instrumental advancements, the accurate molecular assignment of compounds acquired in high resolution mass spectra remains time consuming and requires automated algorithms, especially for samples covering a wide mass range and large numbers of compounds. A new processing scheme is introduced implementing filtering methods based on element assignment, instrumental error, and blank subtraction. Optional post-processing incorporates common ion selection across replicate measurements and shoulder ion removal. The scheme allows both positive and negative direct infusion electrospray ionisation (ESI) and atmospheric pressure photoionisation (APPI) acquisition with the same programs. An example application to atmospheric organic aerosol samples using an Orbitrap mass spectrometer is reported for both ionisation techniques resulting in final spectra with 0.8% and 8.4% of the peaks retained from the raw spectra for APPI positive and ESI negative acquisition, respectively.

  6. The EPA iCSS Chemistry Dashboard to Support Compound Identification Using High Resolution Mass Spectrometry Data (ACS Fall meeting)

    Science.gov (United States)

    Abstract: There is a growing need for rapid chemical screening and prioritization to inform regulatory decision-making on thousands of chemicals in the environment. We have previously used high-resolution mass spectrometry to examine household vacuum dust samples using liquid chr...

  7. Environmental Chemistry Compound Identification Using High Resolution Mass Spectrometry Data Integrated to the EPA Chemistry Dashboard (EAS)

    Science.gov (United States)

    There is a growing need for rapid chemical screening and prioritization to inform regulatory decision-making on thousands of chemicals in the environment. We have previously used high-resolution mass spectrometry to examine household vacuum dust samples using liquid chromatograph...

  8. Screening of plant toxins in food,feed and botanicals using full-scan high-resolution (Orbitrap) mass spectrometry

    NARCIS (Netherlands)

    Mol, J.G.J.; Dam, van R.C.J.; Zomer, P.; Mulder, P.P.J.

    2011-01-01

    A generic method based on LC with full-scan high-resolution (Orbitrap) mass spectrometry (MS) was systematically investigated for the simultaneous detection of a wide range of plant toxins in a variety of food and feed matrices. For a selection of 150 substances, representing various chemical

  9. Targeted metabolite profile of food bioactive compounds by Orbitrap high resolution mass spectrometry: The 'FancyTiles' approach

    NARCIS (Netherlands)

    Troise, A.D.; Ferracane, R.; Palermo, M.; Fogliano, V.

    2014-01-01

    In this paper a new targeted metabolic profile approach using Orbitrap high resolution mass spectrometry was described. For each foodmatrix various classes of bioactive compounds and some specificmetabolites of interest were selected on the basis of the existing knowledge creating an easy-to-read

  10. Analysis of transuranic isotopes in irradiated U3Si2-Al fuel by alpha spectrometry

    International Nuclear Information System (INIS)

    Dian Anggraini; Aslina B Ginting; Arif Nugroho

    2011-01-01

    Separation and analysis of transuranic isotopes (uranium and plutonium) in irradiated U 3 Si 2 -Al plate has been done. The analysis experiment includes sample preparation (i.e. cutting, dissolving, filtering, dilution), fission products separation from heavy elements, and analysis of transuranic isotopes content with alpha spectrometer. The separation of transuranic isotopes (U, Pu) was done by two methods, i.e. direct method and ion exchanger method with zeolite. Measurement of standard transuranic isotope (AMR 43) and standard U 3 O 8 was done in advance in order to determine percentage of 235 U recovery and detector efficiency. Recovery of 235 U isotope was obtained as much as 92,58%, which fulfills validation requirement, and the detector efficiency was 0.314. Based on the measured recovery and detector efficiency, the separation was done by direct electrodeposition method of 250 µL irradiated U 3 Si 2 -Al solution. The deposited sample was subsequently analyzed with alpha spectrometer. The separation with ion exchanger was done by mixing and shaking of 300 µL irradiated U 3 Si 2 -Al solution and 0.5 gram zeolite to separate the liquid phase from the solid phase. The liquid phase was electrodeposited and analyzed with alpha spectrometer. The analysis of transuranic isotopes (U, Pu) by both methods shows different results. Heavy element ( 238 U, 236 U, 234 U, 239 Pu) content obtained by direct method was 0.0525 g/g and 235 U= 0.0076 g/g, while the separation using zeolite ion exchanger resulted in Heavy element = 0.0253 g/g and 235 U = 0.0092 g/g. (author)

  11. Separation of Ra and Th from rock matrices for alpha-spectrometry

    International Nuclear Information System (INIS)

    Ditchburn, R.G.; Whitehead, N.E.

    1995-01-01

    Dating rocks using 226 Ra/ 230 Th isochrons demands radiochemical purification of radium and thorium. This paper presents an improved method. Rocks are solubilised by nitric/hydrofluoric digestion followed by dissolution of insoluble fluorides by boric/nitric acids, and Th is extracted by passing the 8M nitric solution through an anion column in nitrate form. The eluant contains Ra and Ba which are precipitated as sulphate and redissolved in alkaline EDTA. Complete separation of Ba and Ra from sulphate is on an AG 1 x 8 anion column in EDTA form, which was found better than the chloride form. The Ba+Ra is separated on an AG 50W x 8 cation column, and uses CDTA as an eluant for Ba. Careful pH control is essential. Ra elutes later with EDTA or 4M HCl and is precipitated with 125μg barium as sulphate to yield a source suitable for α-spectrometry, or further treated to electroplate the Ra. The yield tracers used are 228 Th and 224 Ra. Because the sample contains natural 224 Ra a correction must be applied, calculated from the amount of natural 232 Th in the Th spectrum. Th may be precipitated with 100 μg of ferric iron and gives a spectrometry-quality source, but further purification and electrodeposition was found to be preferable. Variations on the method for the case of analysis of calcium-rich fish otoliths are described. (author) 37 refs.; 3 figs

  12. Atmospheric Oxidation of Squalene: Molecular Study Using COBRA Modeling and High-Resolution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fooshee, David R.; Aiona, Paige K.; Laskin, Alexander; Laskin, Julia; Nizkorodov, Sergey; Baldi, Pierre

    2015-10-22

    Squalene is a major component of skin and plant surface lipids, and is known to be present at high concentrations in indoor dust. Its high reactivity toward ozone makes it an important ozone sink and a natural protectant against atmospheric oxidizing agents. While the volatile products of squalene ozonolysis are known, the condensed-phase products have not been characterized. We present an analysis of condensed-phase products resulting from an extensive oxidation of squalene by ozone probed by electrospray ionization (ESI) high-resolution mass spectrometry (HR-MS). A complex distribution of nearly 1,300 peaks assignable to molecular formulas is observed in direct infusion positive ion mode ESI mass spectra. The distribution of peaks in the mass spectra suggests that there are extensive cross-coupling reactions between hydroxy-carbonyl products of squalene ozonolysis. To get additional insights into the mechanism, we apply a Computational Brewing Application (COBRA) to simulate the oxidation of squalene in the presence of ozone, and compare predicted results with those observed by the HR-MS experiments. The system predicts over one billion molecular structures between 0-1450 Da, which correspond to about 27,000 distinct elemental formulas. Over 83% of the squalene oxidation products inferred from the mass spectrometry data are matched by the simulation. Simulation indicates a prevalence of peroxy groups, with hydroxyl and ether groups being the second-most important O-containing functional groups formed during squalene oxidation. These highly oxidized products of squalene ozonolysis may accumulate on indoor dust and surfaces, and contribute to their redox capacity.

  13. Contribution to the study of the geophysical behaviour of lead-210 by application of alpha spectrometry; Contribution a l'etude du comportement geophysique du plomb 210 par application de la spectrometrie alpha

    Energy Technology Data Exchange (ETDEWEB)

    Nezami, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    A study of the changes in the lead-210 contents of rain-water and of water produced by melting polar ice has required the development of a method for dosing lead-210, an {alpha} emitter. This method is 40 times more sensitive than that which measures the lead-210 by bismuth-210, a ({beta} emitter. The first part of the report presents the study of a spectrometry using semiconductor detectors; a catalogue of a spectra shows the advantages of this method. In the second part will be found at first a new chemical separation method for polonium-210 and the results obtained with this method. The main results obtained on the geophysical behaviour of lead-210 are the following: - the monthly lead-210 and polonium-210 contents in rain water are approximately constant with time. - in the Gif-sur-Yvette region, the clean-up by 'dry fall-out' can attain 40 to 50 per cent of the total fall-out. - a study of Antarctic ice samples makes it possible to determine an annual accumulation rate equivalent to 13.8 cm of water and to show discrepancies in the periodic concentrations which correspond to the latest maxima of solar activity. - a balance is drawn up between the radon produced by the continents and the lead-210 fall-out. (author) [French] Une etude sur les variations de la teneur en plomb 210 des eaux de pluie et des eaux de fusion des glaces polaires a necessite la mise au point d'une methode de dosage du plomb 210 emetteur {alpha}. Cette methode permet d'obtenir une sensibilite quarante fois superieure a celle dosant le plomb 210 par le bismuth 210 emetteur {beta}. La premiere partie du travail presente l'etude de la spectrometrie {alpha} par detecteur a semiconducteurs, un catalogue de spectres {alpha} met en evidence les avantages de cette methode. Dans la deuxieme partie on trouvera en premier lieu une nouvelle methode chimique de separation du polonium 210 ainsi que les resultats obtenus grace a cette methode. Les principaux resultats sur le comportement geophysique du

  14. Contribution to the study of the geophysical behaviour of lead-210 by application of alpha spectrometry; Contribution a l'etude du comportement geophysique du plomb 210 par application de la spectrometrie alpha

    Energy Technology Data Exchange (ETDEWEB)

    Nezami, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    A study of the changes in the lead-210 contents of rain-water and of water produced by melting polar ice has required the development of a method for dosing lead-210, an {alpha} emitter. This method is 40 times more sensitive than that which measures the lead-210 by bismuth-210, a ({beta} emitter. The first part of the report presents the study of a spectrometry using semiconductor detectors; a catalogue of a spectra shows the advantages of this method. In the second part will be found at first a new chemical separation method for polonium-210 and the results obtained with this method. The main results obtained on the geophysical behaviour of lead-210 are the following: - the monthly lead-210 and polonium-210 contents in rain water are approximately constant with time. - in the Gif-sur-Yvette region, the clean-up by 'dry fall-out' can attain 40 to 50 per cent of the total fall-out. - a study of Antarctic ice samples makes it possible to determine an annual accumulation rate equivalent to 13.8 cm of water and to show discrepancies in the periodic concentrations which correspond to the latest maxima of solar activity. - a balance is drawn up between the radon produced by the continents and the lead-210 fall-out. (author) [French] Une etude sur les variations de la teneur en plomb 210 des eaux de pluie et des eaux de fusion des glaces polaires a necessite la mise au point d'une methode de dosage du plomb 210 emetteur {alpha}. Cette methode permet d'obtenir une sensibilite quarante fois superieure a celle dosant le plomb 210 par le bismuth 210 emetteur {beta}. La premiere partie du travail presente l'etude de la spectrometrie {alpha} par detecteur a semiconducteurs, un catalogue de spectres {alpha} met en evidence les avantages de cette methode. Dans la deuxieme partie on trouvera en premier lieu une nouvelle methode chimique de separation du polonium 210 ainsi que les resultats obtenus grace a cette methode. Les principaux resultats sur le

  15. Derivatives of 16alpha-hydroxy-dehydroepiandrosterone with an additional 7-oxo or 7-hydroxy substituent: synthesis and gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Pouzar, Vladimír; Cerný, Ivan; Hill, Martin; Bicíková, Marie; Hampl, Richard

    2005-10-01

    Derivatives of 16alpha-hydroxy-dehydroepiandrosterone, which have an additional oxygen substituent at position 7 (oxo or hydroxy group), were synthesized. Firstly, 17,17-dimethoxyandrost-5-ene-3beta,16alpha-diyl diacetate was prepared and then oxidized with a complex of chromium(VI) oxide and 2,5-dimethylpyrazole to the respective 7-oxo derivative. This key intermediate was both deprotected or reduced by l-Selectride or sodium borohydride in the presence of cerium(III) chloride and then deprotected to give 7-oxo, 7alpha-hydroxy and 7beta-hydroxy derivatives of 16alpha-hydroxy-dehydroepiandrosterone. The target compounds were characterized by (1)H and (13)C NMR spectra and in the form of O-methyloxime-trimethylsilyl derivatives, by gas chromatography/mass spectrometry methods.

  16. Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lepri, Fabio G.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Borges, Daniel L.G.; Welz, Bernhard; Heitmann, Uwe

    2006-01-01

    Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, L'vov and Khartsyzov proposed to use the non-resonance doublet at 213.5 / 213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 deg. C . The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the

  17. Assessment of meat authenticity using bioinformatics, targeted peptide biomarkers and high-resolution mass spectrometry.

    Science.gov (United States)

    Ruiz Orduna, Alberto; Husby, Erik; Yang, Charles T; Ghosh, Dipankar; Beaudry, Francis

    2015-01-01

    In recent years a significant increase of food fraud has been observed, ranging from false label claims to the use of additives and fillers to increase profitability. Recently in 2013 horse and pig DNAs were detected in beef products sold from several retailers. Mass spectrometry (MS) has become the workhorse in protein research, and the detection of marker proteins could serve for both animal species and tissue authentication. Meat species authenticity is performed in this paper using a well-defined proteogenomic annotation, carefully chosen surrogate tryptic peptides and analysis using a hybrid quadrupole-Orbitrap MS. Selected mammalian meat samples were homogenised and proteins were extracted and digested with trypsin. The samples were analysed using a high-resolution MS. Chromatography was achieved using a 30-min linear gradient along with a BioBasic C8 100 × 1 mm column at a flow rate of 75 µl min(-1). The MS was operated in full-scan high resolution and accurate mass. MS/MS spectra were collected for selected proteotypic peptides. Muscular proteins were methodically analysed in silico in order to generate tryptic peptide mass lists and theoretical MS/MS spectra. Following a comprehensive bottom-up proteomic analysis, we detected and identified a proteotypic myoglobin tryptic peptide (120-134) for each species with observed m/z below 1.3 ppm compared with theoretical values. Moreover, proteotypic peptides from myosin-1, myosin-2 and β-haemoglobin were also identified. This targeted method allowed comprehensive meat speciation down to 1% (w/w) of undesired product.

  18. Determination of Neptunium, Americium and Curium in Spent Nuclear Fuel Samples by Alpha Spectrometry Using 239Np and 243Am as a Spike and a Tracer

    International Nuclear Information System (INIS)

    Jeo, Kih-Soo; Song, Byung-Chul; Kim, Young-Bok; Han, Sun-Ho; Jeon, Young-Shin; Jung, Euo-Chang; Jee, Kwang-Yong

    2007-01-01

    Determination of actinide elements and fission products in spent nuclear fuels is of importance for a burnup determination and source term evaluation. Especially, the amounts of uranium and plutonium isotopes are used for the evaluation of a burnup credit in spent nuclear fuels. Additionally, other actinides such as Np, Am and Cm in spent nuclear fuel samples is also required for the purposes mentioned above. In this study, 237 Np, 241 Am and 244 Cm were determined by an alpha spectrometry for the source term data for high burnup spent nuclear fuels ranging from 37 to 62.9 GWD/MtU as a burnup. Generally, mass spectrometry has been known as the most powerful method for isotope determinations such as high concentrations of uranium and plutonium. However, in the case of minor actinides such as Np, Am and Cm, alpha spectrometry would be recommended instead. Determination of the transuranic elements in spent nuclear fuel samples is different from that for environmental samples because the amount of each nuclide in the spent fuel samples is higher and the relative ratios between each nuclide are also different from those for environmental samples. So, it is important to select an appropriate tracer and an optimum sample size depending on the nuclides and analytical method. In this study 237 Np was determined by an isotope dilution alpha(gamma) spectrometry using 239 Np as a spike, and 241 Am and curium isotopes were determined by alpha spectrometry using 243 Am as a tracer. The content of each nuclide was compared with that by the Origen-2 code

  19. Advances in high-resolution mass spectrometry based on metabolomics studies for food--a review.

    Science.gov (United States)

    Rubert, Josep; Zachariasova, Milena; Hajslova, Jana

    2015-01-01

    Food authenticity becomes a necessity for global food policies, since food placed in the market without fail has to be authentic. It has always been a challenge, since in the past minor components, called also markers, have been mainly monitored by chromatographic methods in order to authenticate the food. Nevertheless, nowadays, advanced analytical methods have allowed food fingerprints to be achieved. At the same time they have been also combined with chemometrics, which uses statistical methods in order to verify food and to provide maximum information by analysing chemical data. These sophisticated methods based on different separation techniques or stand alone have been recently coupled to high-resolution mass spectrometry (HRMS) in order to verify the authenticity of food. The new generation of HRMS detectors have experienced significant advances in resolving power, sensitivity, robustness, extended dynamic range, easier mass calibration and tandem mass capabilities, making HRMS more attractive and useful to the food metabolomics community, therefore becoming a reliable tool for food authenticity. The purpose of this review is to summarise and describe the most recent metabolomics approaches in the area of food metabolomics, and to discuss the strengths and drawbacks of the HRMS analytical platforms combined with chemometrics.

  20. Metabolite profiling of carbamazepine and ibuprofen in Solea senegalensis bile using high-resolution mass spectrometry.

    Science.gov (United States)

    Aceña, Jaume; Pérez, Sandra; Eichhorn, Peter; Solé, Montserrat; Barceló, Damià

    2017-09-01

    The widespread occurrence of pharmaceuticals in the aquatic environment has raised concerns about potential adverse effects on exposed wildlife. Very little is currently known on exposure levels and clearance mechanisms of drugs in marine fish. Within this context, our research was focused on the identification of main metabolic reactions, generated metabolites, and caused effects after exposure of fish to carbamazepine (CBZ) and ibuprofen (IBU). To this end, juveniles of Solea senegalensis acclimated to two temperature regimes of 15 and 20 °C for 60 days received a single intraperitoneal dose of these drugs. A control group was administered the vehicle (sunflower oil). Bile samples were analyzed by ultra-high-performance liquid chromatography-high-resolution mass spectrometry on a Q Exactive (Orbitrap) system, allowing to propose plausible identities for 11 metabolites of CBZ and 13 metabolites of IBU in fish bile. In case of CBZ metabolites originated from aromatic and benzylic hydroxylation, epoxidation, and ensuing O-glucuronidation, O-methylation of a catechol-like metabolite was also postulated. Ibuprofen, in turn, formed multiple hydroxyl metabolites, O-glucuronides, and (hydroxyl)-acyl glucuronides, in addition to several taurine conjugates. Enzymatic responses after drug exposures revealed a water temperature-dependent induction of microsomal carboxylesterases. The metabolite profiling in fish bile provides an important tool for pharmaceutical exposure assessment. Graphical abstract Studies of metabolism of carbamazepine and ibuprofen in fish.

  1. Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Dessuy, Morgana B.; Vale, Maria Goreti R.; Lepri, Fabio G.; Welz, Bernhard; Heitmann, Uwe

    2007-01-01

    The atomization of phosphorus in electrothermal atomic absorption spectrometry has been investigated using a high-resolution continuum source atomic absorption spectrometer and atomization from a graphite platform as well as from a tantalum boat inserted in a graphite tube. A two-step atomization mechanism is proposed for phosphorus, where the first step is a thermal dissociation, resulting in a fast atomization signal early in the atomization stage, and the second step is a slow release of phosphorus atoms from the graphite tube surface following the adsorption of molecular phosphorus at active sites of the graphite surface. Depending on experimental conditions only one of the mechanisms or both might be active. In the absence of a modifier and with atomization from a graphite or tantalum platform the second mechanism appears to be dominant, whereas in the presence of sodium fluoride as a modifier both mechanisms are observed. Intercalation of phosphorus into the graphite platform in the condensed phase has also been observed; this phosphorus, however, appears to be permanently trapped in the structure of the graphite and does not contribute to the absorption signal

  2. Peptide Peak Detection for Low Resolution MALDI-TOF Mass Spectrometry.

    Science.gov (United States)

    Yao, Jingwen; Utsunomiya, Shin-Ichi; Kajihara, Shigeki; Tabata, Tsuyoshi; Aoshima, Ken; Oda, Yoshiya; Tanaka, Koichi

    2014-01-01

    A new peak detection method has been developed for rapid selection of peptide and its fragment ion peaks for protein identification using tandem mass spectrometry. The algorithm applies classification of peak intensities present in the defined mass range to determine the noise level. A threshold is then given to select ion peaks according to the determined noise level in each mass range. This algorithm was initially designed for the peak detection of low resolution peptide mass spectra, such as matrix-assisted laser desorption/ionization Time-of-Flight (MALDI-TOF) mass spectra. But it can also be applied to other type of mass spectra. This method has demonstrated obtaining a good rate of number of real ions to noises for even poorly fragmented peptide spectra. The effect of using peak lists generated from this method produces improved protein scores in database search results. The reliability of the protein identifications is increased by finding more peptide identifications. This software tool is freely available at the Mass++ home page (http://www.first-ms3d.jp/english/achievement/software/).

  3. The Determination of Thorium Contents in Urine With Neutron Activation Analysis and Alpha Spectrometry

    International Nuclear Information System (INIS)

    Mukh-Syaifudin

    2007-01-01

    Internal contamination by a radionuclide that entered into body through inhalation is most conveniently determined by using urine as sample. The aim of this research was developing a fast and simple method to determine thorium content in urine. The method was based on comparison of the activities between the sample added with and without standard thorium. Urine sample was divided into two parts, one of which was added with Th-232 standard, and then both were simultaneously proceed which was consist of decomposition of organic materials, precipitation of thorium by adding ammonium hydroxide, wash with aquadest, and then dissolution in nitric acid. The solution was then activated for 15 minutes with neutron flux of 10 12 ncm -2 second -1 and the activated product was co-precipitated two times with lanthanum carrier and sodium chloride by addition of ammonium hydroxide. Finally, the precipitate was dissolved in nitric acid and the gamma emission of Th-233 was analyzed with gamma spectrometry. The results of analysis showed that the concentration of four urine samples analyzed was below detection limit (BDL); 200.40; 273.88 and 22.03 pg/l, respectively. With the simple procedure, neutron activation analysis can be used in the determining the actinide contents in several types of biological sample. (author)

  4. Contribution to the study of the geophysical behaviour of lead-210 by application of alpha spectrometry

    International Nuclear Information System (INIS)

    Nezami, M.

    1965-06-01

    A study of the changes in the lead-210 contents of rain-water and of water produced by melting polar ice has required the development of a method for dosing lead-210, an α emitter. This method is 40 times more sensitive than that which measures the lead-210 by bismuth-210, a (β emitter. The first part of the report presents the study of a spectrometry using semiconductor detectors; a catalogue of a spectra shows the advantages of this method. In the second part will be found at first a new chemical separation method for polonium-210 and the results obtained with this method. The main results obtained on the geophysical behaviour of lead-210 are the following: - the monthly lead-210 and polonium-210 contents in rain water are approximately constant with time. - in the Gif-sur-Yvette region, the clean-up by 'dry fall-out' can attain 40 to 50 per cent of the total fall-out. - a study of Antarctic ice samples makes it possible to determine an annual accumulation rate equivalent to 13.8 cm of water and to show discrepancies in the periodic concentrations which correspond to the latest maxima of solar activity. - a balance is drawn up between the radon produced by the continents and the lead-210 fall-out. (author) [fr

  5. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Perez Sanchez, D.; Martin Sanchez, A.; Jurado Vargas, M.

    2003-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples from the same matrix. Sediment samples are decomposed by leaching with mineral acids or by microwave digestion, while water samples are pre-concentrated. One part of the resulting solution, spiked with 209 Po, is used for 210 Po determination by spontaneous deposition onto nickel disks (a-spectrometry). The other part is assayed for 210 Pb, separating the Pb either by anion-exchange (sediment samples), or by solvent extraction (water samples). The 210 Pb source is finally prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The 210 Pb activity concentration is determined by liquid scintillation. A standard sediment sample supplied by IAEA and spiked water samples were analysed to check the procedure. The 210 Pb and 210 Po measurements agreed well with the certifications, deviations being less than 10%. The mean recoveries for Pb and Po were (70±12)% and (77±8)% for sediments, and (70±10)% and (81±7)% for waters, respectively. (author)

  6. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  7. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry

    International Nuclear Information System (INIS)

    Lin Zhichao; Wu Zhongyu

    2009-01-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of 210 Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  8. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry.

    Science.gov (United States)

    Lin, Zhichao; Wu, Zhongyu

    2009-05-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of (210)Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  9. Radionuclide content of simulated and fully radioactive SRLLL waste glasses: comparison of results from ICP-MS, gamma spectrometry and alpha spectrometry

    International Nuclear Information System (INIS)

    Wolf, S.F.; Bates, J.K.

    1995-01-01

    We have measured the transuranic content of two transuranic=doped, simulated waste glasses, using inductively coupled plasma-mass spectrometry (ICP-MS), γ-spectrometry, and α-spectrometry. Average concentrations measured by each technique were within ± 10% of the as-doped concentrations. We also report the transuranic content of three fully radioactive SRL waste glasses that were determined using γ- and α-spectrometry measurements to deconvolute isobaric interferences present in the ICP-MS analyses

  10. Application of the alpha spectrometry for the study of core sediment extracted in the San Marcos dam in Chihuahua

    Energy Technology Data Exchange (ETDEWEB)

    Mendez G, C.; Renteria V, M.; Montero C, M. E. [Centro de Investigacion en Materiales Avanzados, S. C., Miguel de Cervantes No. 120, Complejo Industrial Chihuahua, 31109 Chihuahua (Mexico); Garcia T, R., E-mail: elena.montero@cimav.edu.mx [Universidad de Sevilla, Escuela Tecnica Superior de Arquitectura, Grupo de Fisica Nuclear Aplicada, Av. Reina Mercedes s/n, 41012 Sevilla (Spain)

    2012-06-15

    The determination of the specific activities of {sup 210}Po and isotopic uranium by alpha spectrometry was performed in a sediment core from San Marcos Dam. The objective of this work was to analyze the vertical distribution of isotopic uranium and {sup 210}Po and the behavior of these radionuclides along sediment core collected from the San Marcos Dam. Sample was divided into 11 sections, in which {sup 210}Po and isotopic uranium were determined using liquid-liquid extraction with tributyl phosphate. Furthermore, it was made a comparison between the tributyl phosphate technique and the technique of extraction chromatography using UTEVA resins for uranium. The results of specific activities for {sup 210}Po show a trend to decrease along the core, whereas the uranium isotopic does not show a pointed trend. The results of isotopic ratios between the {sup 234}U and {sup 238}U show that they are close to secular equilibrium in each of the core sections. The comparison between the two uranium extraction techniques indicates that the chemical yield is better using the UTEVA technique than tributyl phosphate extraction. (Author)

  11. Alpha liquid-scintillation spectrometry used for the measurement of uranium/thorium-disequilibria in soil samples

    International Nuclear Information System (INIS)

    Fueeg, B.; Tschachtli, T.; Kraehenbuehl, U.

    1997-01-01

    For the measurements of low-level radioactivity of natural samples. It is of interest to have a system with high counting efficiency. Alpha liquid-scintillation spectrometry is attractive, because it offers a 4 π geometry. Some chemical separation can be obtained using extractive scintillators. Due to quenching problems for natural samples, additional separation power is needed. A new sample preparation method was developed employing extraction chromatographic resin for measuring 238 U, 234 U, 232 Th, 230 Th, 228 Th and 226 Ra in soil samples, without using any uranium- or thorium-tracer for determining the chemical yields. This method was tested by analyzing the two different reference materials, IAEA-375, soil from Tschernobyl, as well as IAEA SDA-1, a deep-sea sediment with a high calcium content. For all analyzed radionuclides the recoveries were better than 90% with errors (confidence level of 95%) smaller than 5%. The minimal detectable concentration ranges between 0.2 and 0.8 Bq/kg, based on a one gram aliquot of sample and 80'000 seconds counting time. (orig.)

  12. Application of the alpha spectrometry for the study of core sediment extracted in the San Marcos dam in Chihuahua

    International Nuclear Information System (INIS)

    Mendez G, C.; Renteria V, M.; Montero C, M. E.; Garcia T, R.

    2012-01-01

    The determination of the specific activities of 210 Po and isotopic uranium by alpha spectrometry was performed in a sediment core from San Marcos Dam. The objective of this work was to analyze the vertical distribution of isotopic uranium and 210 Po and the behavior of these radionuclides along sediment core collected from the San Marcos Dam. Sample was divided into 11 sections, in which 210 Po and isotopic uranium were determined using liquid-liquid extraction with tributyl phosphate. Furthermore, it was made a comparison between the tributyl phosphate technique and the technique of extraction chromatography using UTEVA resins for uranium. The results of specific activities for 210 Po show a trend to decrease along the core, whereas the uranium isotopic does not show a pointed trend. The results of isotopic ratios between the 234 U and 238 U show that they are close to secular equilibrium in each of the core sections. The comparison between the two uranium extraction techniques indicates that the chemical yield is better using the UTEVA technique than tributyl phosphate extraction. (Author)

  13. Estimation of polonium concentration in groundwater samples from the Peddagattu/Nambapur and Seripalli regions using alpha-spectrometry

    International Nuclear Information System (INIS)

    Raghavendra, T.; Srilatha, K.; Mahender, C.; Elender; Vijaya Lakshmi, T.; Himabindu, V.; Vishwa Prasad; Padma Savithri, P.; Datta, D.; Arunachalam, J.

    2013-01-01

    The decay of uranium series in the earth crust remains the final and long lived radionuclides 210 Po and 210 Pb in the environment. Their presence in the atmosphere is due to the decay of 222 Rn diffusing from the ground. This study was carried out with an objective of estimation of polonium concentration in a uranium mineralized zone in Peddagattu and Seripalli areas of Nalgonda district, Andhra Pradesh, India. Groundwater samples were collected from 12 wells, and frequency of these collections was once in a quarter from May 2010 to Dec 2011. The alpha-spectrometry has been applied to analyze these samples. Observation reveals that the activity concentration of Polonium in the water samples of Peddagattu and Seripally regions range from 0.3 mBq/l to 2.80 mBq/l with Geometric mean of 0.89 mBq/l and Geometric Standard deviation of 2.72 and from 0.3 mBq/l to 4.68 mBq/l with a Geometric mean of 0.91 and Geometric standard deviation of 3.22 respectively. As per WHO standards, the maximum permissible limit in drinking water for Polonium is 0.55 Bq/l. Hence all the 12 samples are falling well under the permissible limit. This paper presents the analytical details for estimating polonium as a natural radioactive element in groundwater as well as surface water samples collected from the Nambapur/Peddagattu and Seripalli regions. (author)

  14. Low resolution solution structure of HAMLET and the importance of its alpha-domains in tumoricidal activity.

    Science.gov (United States)

    Ho, C S James; Rydstrom, Anna; Manimekalai, Malathy Sony Subramanian; Svanborg, Catharina; Grüber, Gerhard

    2012-01-01

    HAMLET (Human Alpha-lactalbumin Made LEthal to Tumor cells) is the first member in a new family of protein-lipid complexes with broad tumoricidal activity. Elucidating the molecular structure and the domains crucial for HAMLET formation is fundamental for understanding its tumoricidal function. Here we present the low-resolution solution structure of the complex of oleic acid bound HAMLET, derived from small angle X-ray scattering data. HAMLET shows a two-domain conformation with a large globular domain and an extended part of about 2.22 nm in length and 1.29 nm width. The structure has been superimposed into the related crystallographic structure of human α-lactalbumin, revealing that the major part of α-lactalbumin accommodates well in the shape of HAMLET. However, the C-terminal residues from L105 to L123 of the crystal structure of the human α-lactalbumin do not fit well into the HAMLET structure, resulting in an extended conformation in HAMLET, proposed to be required to form the tumoricidal active HAMLET complex with oleic acid. Consistent with this low resolution structure, we identified biologically active peptide epitopes in the globular as well as the extended domains of HAMLET. Peptides covering the alpha1 and alpha2 domains of the protein triggered rapid ion fluxes in the presence of sodium oleate and were internalized by tumor cells, causing rapid and sustained changes in cell morphology. The alpha peptide-oleate bound forms also triggered tumor cell death with comparable efficiency as HAMLET. In addition, shorter peptides corresponding to those domains are biologically active. These findings provide novel insights into the structural prerequisites for the dramatic effects of HAMLET on tumor cells.

  15. Alpha spectrometry Analysis of radioisotopes of thorium and uranium in the soil (IAEA soil reference ground 375 and the natural region of Utique (Bizerte))

    International Nuclear Information System (INIS)

    Mejri, Mouna

    2008-01-01

    Since the formation of the terrestrial crust, the primordial radionuclides are present in the minerals. The main are the radioactive elemnts of the Uranium 238, of Uranium 235, of the Thorium 232 chains, Potassium 40 and the Ribidium 87. In this survey, we will present the methodology of analysis of the natural radioisotopes of uranium ( 238 U, 235 U and 234 U) and those of the thorium ( 232 Th, 230 Th and 228 Th) presents to the state of tracers in the natural soils. The method of measurement used is the alpha spectrometry. This technique is very important in the radiometric analysis, especially for the pure alpha emitters or for the low levels of radioactivity analysis. The results if analysis of the Thorium are compared to those gotten by the ICP - AES ( t he Atomic Emission Spectrometry Coupled to an inductive Plasma ) . (Author)

  16. Resolution of co-eluting compounds of Cannabis Sativa in comprehensive two-dimensional gas chromatography/mass spectrometry detection with Multivariate Curve Resolution-Alternating Least Squares.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Amigo, José Manuel; Etxebarria, Nestor

    2014-04-01

    Comprehensive Two Dimensional Gas Chromatography - Mass Spectrometry (GC × GC/qMS) analysis of Cannabis sativa extracts shows a high complexity due to the large variety of terpenes and cannabinoids and to the fact that the complete resolution of the peaks is not straightforwardly achieved. In order to support the resolution of the co-eluted peaks in the sesquiterpene and the cannabinoid chromatographic region the combination of Multivariate Curve Resolution and Alternating Least Squares algorithms was satisfactorily applied. As a result, four co-eluting areas were totally resolved in the sesquiterpene region and one in the cannabinoid region in different samples of Cannabis sativa. The comparison of the mass spectral profiles obtained for each resolved peak with theoretical mass spectra allowed the identification of some of the co-eluted peaks. Finally, the classification of the studied samples was achieved based on the relative concentrations of the resolved peaks. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Gas-phase fragmentation of peptides to increase the spatial resolution of the Hydrogen Exchange Mass Spectrometry experiment

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Rand, Kasper Dyrberg

    2016-01-01

    are produced after precursor ion selection and thus do not add complexity to the LC-MS analysis. The key to obtaining optimal spatial resolution in a hydrogen exchange mass spectrometry (HX-MS) experiment is the fragmentation efficiency. This chapter discusses common fragmentation techniques like collision....../D scrambling, thus making them suitable for HX applications. By combining the classic bottom-up HX-MS workflow with gas-phase fragmentation by ETD, detailed information on protein HX can be obtained....

  18. Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products

    Science.gov (United States)

    Kowalewska, Zofia

    2011-07-01

    For the first time, high-resolution molecular absorption spectrometry with a high-intensity xenon lamp as radiation source has been applied for the determination of sulphur in crude oil and petroleum products. The samples were analysed as xylene solutions using vaporisation in acetylene-air flame or in an electrothermally heated graphite furnace. The sensitive rotational lines of the CS molecule, belonging to the ∆ν = 0 vibrational sequence within the electronic transition X 1∑ + → A 1П, were applied. For graphite furnace molecular absorption spectrometry, the Pd + Mg organic modifier was selected. Strong interactions with Pd atoms enable easier decomposition of sulphur-containing compounds, likely through the temporal formation of Pd xS y molecules. At the 258.056 nm line, with the wavelength range covering central pixel ± 5 pixels and with application of interactive background correction, the detection limit was 14 ng in graphite furnace molecular absorption spectrometry and 18 mg kg -1 in flame molecular absorption spectrometry. Meanwhile, application of 2-points background correction found a characteristic mass of 12 ng in graphite furnace molecular absorption spectrometry and a characteristic concentration of 104 mg kg -1 in flame molecular absorption spectrometry. The range of application of the proposed methods turned out to be significantly limited by the properties of the sulphur compounds of interest. In the case of volatile sulphur compounds, which can be present in light petroleum products, severe difficulties were encountered. On the contrary, heavy oils and residues from distillation as well as crude oil could be analysed using both flame and graphite furnace vaporisation. The good accuracy of the proposed methods for these samples was confirmed by their mutual consistency and the results from analysis of reference samples (certified reference materials and home reference materials with sulphur content determined by X-ray fluorescence

  19. Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Kowalewska, Zofia, E-mail: zofia.kowalewska@obr.pl

    2011-07-15

    For the first time, high-resolution molecular absorption spectrometry with a high-intensity xenon lamp as radiation source has been applied for the determination of sulphur in crude oil and petroleum products. The samples were analysed as xylene solutions using vaporisation in acetylene-air flame or in an electrothermally heated graphite furnace. The sensitive rotational lines of the CS molecule, belonging to the {Delta}{nu} = 0 vibrational sequence within the electronic transition X{sup 1}{Sigma}{sup +} {yields} A{sup 1}{Pi}, were applied. For graphite furnace molecular absorption spectrometry, the Pd + Mg organic modifier was selected. Strong interactions with Pd atoms enable easier decomposition of sulphur-containing compounds, likely through the temporal formation of Pd{sub x}S{sub y} molecules. At the 258.056 nm line, with the wavelength range covering central pixel {+-} 5 pixels and with application of interactive background correction, the detection limit was 14 ng in graphite furnace molecular absorption spectrometry and 18 mg kg{sup -1} in flame molecular absorption spectrometry. Meanwhile, application of 2-points background correction found a characteristic mass of 12 ng in graphite furnace molecular absorption spectrometry and a characteristic concentration of 104 mg kg{sup -1} in flame molecular absorption spectrometry. The range of application of the proposed methods turned out to be significantly limited by the properties of the sulphur compounds of interest. In the case of volatile sulphur compounds, which can be present in light petroleum products, severe difficulties were encountered. On the contrary, heavy oils and residues from distillation as well as crude oil could be analysed using both flame and graphite furnace vaporisation. The good accuracy of the proposed methods for these samples was confirmed by their mutual consistency and the results from analysis of reference samples (certified reference materials and home reference materials with

  20. Non-targeted glycosidic profiling of international wines using neutral loss-high resolution mass spectrometry.

    Science.gov (United States)

    Barnaba, C; Dellacassa, E; Nicolini, G; Nardin, T; Serra, M; Larcher, R

    2018-07-06

    Many metabolites naturally occur as glycosides, since sugar moieties can be crucial for their biological activity and increase their water solubility. In the plant kingdom they may occur as glycosides or sugar esters, depending on precursor chemical structure, and in wine they have traditionally attracted attention due to their organoleptic properties, such as astringency and bitterness, and because they affect the colour and aroma of wines. A new approach directed at detailed description of glycosides in a large selection of monovarietal wines (8 samples each of Pinot Blanc, Muller Thurgau, Riesling, Traminer, Merlot, Pinot Noir and Cabernet Sauvignon) was developed by combining high performance liquid chromatography with high resolution tandem mass spectrometry. Analytical separation was performed on an Accucore™ Polar Premium LC column, while mass analysis was performed in negative ion mode with an non-targeted screening approach, using a Full MS/AIF/NL dd-MS 2 experiment at a resolving power of 140,000 FWHM. Over 280 glycoside-like compounds were detected, of which 133 (including low-molecular weight phenols, flavonoids and monoterpenols) were tentatively identified in the form of pentose (6), deoxyhexose (17), hexose (73), hexose-pentose (16), hexose-deoxyhexose (7), dihexose (5) and hexose ester (9) derivatives. It was not possible to univocally define the corresponding chemical structure for the remaining 149 glycosides. Non-parametric statistical analysis showed it was possible to well characterise the glycosylated profile of all red and Traminer wines, while the identified glycosides were almost entirely lacking in Pinot Blanc, Riesling and Muller Thurgau wines. Also Tukey's Honestly Significant Difference test (p wines from each other according to their glycosylated profile. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Similarity of High-Resolution Tandem Mass Spectrometry Spectra of Structurally Related Micropollutants and Transformation Products

    Science.gov (United States)

    Schollée, Jennifer E.; Schymanski, Emma L.; Stravs, Michael A.; Gulde, Rebekka; Thomaidis, Nikolaos S.; Hollender, Juliane

    2017-12-01

    High-resolution tandem mass spectrometry (HRMS2) with electrospray ionization is frequently applied to study polar organic molecules such as micropollutants. Fragmentation provides structural information to confirm structures of known compounds or propose structures of unknown compounds. Similarity of HRMS2 spectra between structurally related compounds has been suggested to facilitate identification of unknown compounds. To test this hypothesis, the similarity of reference standard HRMS2 spectra was calculated for 243 pairs of micropollutants and their structurally related transformation products (TPs); for comparison, spectral similarity was also calculated for 219 pairs of unrelated compounds. Spectra were measured on Orbitrap and QTOF mass spectrometers and similarity was calculated with the dot product. The influence of different factors on spectral similarity [e.g., normalized collision energy (NCE), merging fragments from all NCEs, and shifting fragments by the mass difference of the pair] was considered. Spectral similarity increased at higher NCEs and highest similarity scores for related pairs were obtained with merged spectra including measured fragments and shifted fragments. Removal of the monoisotopic peak was critical to reduce false positives. Using a spectral similarity score threshold of 0.52, 40% of related pairs and 0% of unrelated pairs were above this value. Structural similarity was estimated with the Tanimoto coefficient and pairs with higher structural similarity generally had higher spectral similarity. Pairs where one or both compounds contained heteroatoms such as sulfur often resulted in dissimilar spectra. This work demonstrates that HRMS2 spectral similarity may indicate structural similarity and that spectral similarity can be used in the future to screen complex samples for related compounds such as micropollutants and TPs, assisting in the prioritization of non-target compounds. [Figure not available: see fulltext.

  2. An ultra-sensitive instrument for collision activated dissociation mass spectrometry with high mass resolution

    International Nuclear Information System (INIS)

    Louter, G.J.

    1982-01-01

    During the last decade Collision Activated Dissociation Mass Spectrometry (CAD-MS) has developed into an important and sometimes unique technique for the structure elucidation of ions. An extensive description of the double stage MS is given, which has been especially devloped for CAD-MS. A high mass resolution and a very high sensitivity are obtained by application of special techniques like post-acceleration of fragment ions, quadrupole (Q-pole) lenses and an electro-optical, simultaneous ion detection system. The operation of the rather complex ion-optics is demonstrated by application of a computer simulation of the tandem MS. Special attention is given to the action of the four Q-pole lenses and the second sector magnet upon curvature and position of the mass focal plane. Two mass calibration methods are described for the fragment spectra. The so-called polynomial-method applies a fifth-order polynomial approximation of the functional relation between position on the detector and corresponding relative momentum of fragment ions. The second method uses the matrix model of the instrument. The detector consists of two channelplates (CEMA), a fibre optics slab, coated with a phosphor layer, a camera objective and a 1024-channels photodiode-array. A bio-chemical and an organic-chemical application of the instrument are given. As bio-chemical application the peak m/z 59 in the pyrolysis mass spectrum of complete mycobacteria is identified. As an example of organic-chemical application the fragmentation process of 2,3-butadienoic acid has been investigated. (Auth.)

  3. Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Masayoshi Tamura

    2014-08-01

    Full Text Available Fumonisin A-series (FAs in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS. Peaks for fumonisin B1 (FB1, fumonisin B2 (FB2, and fumonisin B3 (FB3, in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200–800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50–200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I–III revealed structural similarities to FBs, only differing by an additional C2H2O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1 synthesized from FB1 standards, compounds I–III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1, A2 (FA2, and A3 (FA3. The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg.

  4. Characterization of fumonisin A-series by high-resolution liquid chromatography-orbitrap mass spectrometry.

    Science.gov (United States)

    Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Toriba, Akira; Hayakawa, Kazuichi

    2014-08-21

    Fumonisin A-series (FAs) in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS). Peaks for fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3), in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200-800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50-200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I-III revealed structural similarities to FBs, only differing by an additional C2H2O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1) synthesized from FB1 standards, compounds I-III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1), A2 (FA2), and A3 (FA3). The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg.

  5. Characterization of unknown iodinated disinfection byproducts during chlorination/chloramination using ultrahigh resolution mass spectrometry

    International Nuclear Information System (INIS)

    Wang, Xin; Wang, Juan; Zhang, Yahe; Shi, Quan; Zhang, Haifeng; Zhang, Yu; Yang, Min

    2016-01-01

    Iodinated disinfection byproducts (I-DBPs), formed from the reaction of disinfectant(s) with organic matter in the presence of iodide in raw water, have recently been focused because of their more cytotoxic and genotoxic properties than their chlorinated or brominated analogues. To date, only a few I-DBPs in drinking water have been identified. In this study, C18 solid phase extraction coupled with electrospray ionization ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) was used to characterize unknown I-DBPs in chloraminated/chlorinated water spiked with iodide and humic substances. In total, 178 formulas for one-iodine-containing products, 13 formulas for two-iodine-containing products, and 15 formulas for one-chlorine and one-iodine-containing products were detected in the chloraminated water sample, while only 9 formulas for one-iodine-containing products and 6 formulas for one-chlorine and one-iodine-containing products were found in the chlorinated water sample. Most I-DBPs have corresponding chlorine-containing analogues with identical CHO compositions. As indicated by the modified aromaticity index (AI mod ), in the C18 extracts, more than 68% of the I-DBPs have aromatic structures or polycyclic aromatic structures. This result demonstrates that the use of chloramination as an alternative disinfection method may lead to the formation of abundant species of I-DBPs in the presence of iodide. Thus, the suitability of adopting chloramination as an alternative disinfection method should be reevaluated, particularly when iodide is present in raw water. - Highlights: • The formulas of 206 iodinated DBPs in chloraminated drinking water were proposed. • More than 68% of the I-DBPs might have aromatic or polycyclic aromatic structures. • Precursors with high aromaticity is preferential to form iodinated DBPs.

  6. Characterization of unknown iodinated disinfection byproducts during chlorination/chloramination using ultrahigh resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xin; Wang, Juan [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Zhang, Yahe; Shi, Quan [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Zhang, Haifeng; Zhang, Yu [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Yang, Min, E-mail: yangmin@rcees.ac.cn [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2016-06-01

    Iodinated disinfection byproducts (I-DBPs), formed from the reaction of disinfectant(s) with organic matter in the presence of iodide in raw water, have recently been focused because of their more cytotoxic and genotoxic properties than their chlorinated or brominated analogues. To date, only a few I-DBPs in drinking water have been identified. In this study, C18 solid phase extraction coupled with electrospray ionization ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) was used to characterize unknown I-DBPs in chloraminated/chlorinated water spiked with iodide and humic substances. In total, 178 formulas for one-iodine-containing products, 13 formulas for two-iodine-containing products, and 15 formulas for one-chlorine and one-iodine-containing products were detected in the chloraminated water sample, while only 9 formulas for one-iodine-containing products and 6 formulas for one-chlorine and one-iodine-containing products were found in the chlorinated water sample. Most I-DBPs have corresponding chlorine-containing analogues with identical CHO compositions. As indicated by the modified aromaticity index (AI{sub mod}), in the C18 extracts, more than 68% of the I-DBPs have aromatic structures or polycyclic aromatic structures. This result demonstrates that the use of chloramination as an alternative disinfection method may lead to the formation of abundant species of I-DBPs in the presence of iodide. Thus, the suitability of adopting chloramination as an alternative disinfection method should be reevaluated, particularly when iodide is present in raw water. - Highlights: • The formulas of 206 iodinated DBPs in chloraminated drinking water were proposed. • More than 68% of the I-DBPs might have aromatic or polycyclic aromatic structures. • Precursors with high aromaticity is preferential to form iodinated DBPs.

  7. Software tool for resolution of inverse problems using artificial intelligence techniques: an application in neutron spectrometry

    International Nuclear Information System (INIS)

    Castaneda M, V. H.; Martinez B, M. R.; Solis S, L. O.; Castaneda M, R.; Leon P, A. A.; Hernandez P, C. F.; Espinoza G, J. G.; Ortiz R, J. M.; Vega C, H. R.; Mendez, R.; Gallego, E.; Sousa L, M. A.

    2016-10-01

    The Taguchi methodology has proved to be highly efficient to solve inverse problems, in which the values of some parameters of the model must be obtained from the observed data. There are intrinsic mathematical characteristics that make a problem known as inverse. Inverse problems appear in many branches of science, engineering and mathematics. To solve this type of problem, researches have used different techniques. Recently, the use of techniques based on Artificial Intelligence technology is being explored by researches. This paper presents the use of a software tool based on artificial neural networks of generalized regression in the solution of inverse problems with application in high energy physics, specifically in the solution of the problem of neutron spectrometry. To solve this problem we use a software tool developed in the Mat Lab programming environment, which employs a friendly user interface, intuitive and easy to use for the user. This computational tool solves the inverse problem involved in the reconstruction of the neutron spectrum based on measurements made with a Bonner spheres spectrometric system. Introducing this information, the neural network is able to reconstruct the neutron spectrum with high performance and generalization capability. The tool allows that the end user does not require great training or technical knowledge in development and/or use of software, so it facilitates the use of the program for the resolution of inverse problems that are in several areas of knowledge. The techniques of Artificial Intelligence present singular veracity to solve inverse problems, given the characteristics of artificial neural networks and their network topology, therefore, the tool developed has been very useful, since the results generated by the Artificial Neural Network require few time in comparison to other techniques and are correct results comparing them with the actual data of the experiment. (Author)

  8. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Science.gov (United States)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L- 1 HNO3 solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L- 1 and 36.4 mg L- 1, respectively. The repeatability of the results expressed as relative standard deviation was typically beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93-105% with the repeatability in the range of 4.1-5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg- 1), egg white (2188 ± 29 mg kg- 1), mineral water (31.0 ± 0.9 mg L- 1), white wine (260 ± 4 mg L- 1) and red wine (82 ± 2 mg L- 1), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L- 1).

  9. Optimization of the detector and associated electronics used for high-resolution liquid-scintillation alpha spectroscopy

    International Nuclear Information System (INIS)

    Thorngate, J.H.; Christian, D.J.

    1977-01-01

    The performance of various reflector geometries, light coupling liquids, photomultiplier tubes, preamplifiers and linear amplifiers were compared and the configuration found that optimized the combination of pulse-height resolution and pulse-shape discrimination. The best combination used a hemispherical reflector, filled with distilled water, coupled to an 8575 photomultiplier tube, the output of which was conditioned by a special integrating preamplifier and a double-delay-line linear amplifier. Careful choice of the scintillator, sample preparation procedures, and electronic apparatus can produce liquid-scintillation alpha spectroscopy with a pulse-height resolution of 300 keV, or less, and, by using pulse-shape discrimination, background levels as low as 0.01 counts/min. (author)

  10. DETECTING LOW-LEVEL SYNTHESIS IMPURITIES IN MODIFIED PHOSPHOROTHIOATE OLIGONUCLEOTIDES USING LIQUID CHROMATOGRAPHY – HIGH RESOLUTION MASS SPECTROMETRY

    Science.gov (United States)

    Nikcevic, Irena; Wyrzykiewicz, Tadeusz K.; Limbach, Patrick A.

    2010-01-01

    Summary An LC-MS method based on the use of high resolution Fourier transform ion cyclotron resonance mass spectrometry (FTIRCMS) for profiling oligonucleotides synthesis impurities is described. Oligonucleotide phosphorothioatediesters (phosphorothioate oligonucleotides), in which one of the non-bridging oxygen atoms at each phosphorus center is replaced by a sulfur atom, are now one of the most popular oligonucleotide modifications due to their ease of chemical synthesis and advantageous pharmacokinetic properties. Despite significant progress in the solid-phase oligomerization chemistry used in the manufacturing of these oligonucleotides, multiple classes of low-level impurities always accompany synthetic oligonucleotides. Liquid chromatography-mass spectrometry has emerged as a powerful technique for the identification of these synthesis impurities. However, impurity profiling, where the entire complement of low-level synthetic impurities is identified in a single analysis, is more challenging. Here we present an LC-MS method based the use of high resolution-mass spectrometry, specifically Fourier transform ion cyclotron resonance mass spectrometry (FTIRCMS or FTMS). The optimal LC-FTMS conditions, including the stationary phase and mobile phases for the separation and identification of phosphorothioate oligonucleotides, were found. The characteristics of FTMS enable charge state determination from single m/z values of low-level impurities. Charge state information then enables more accurate modeling of the detected isotopic distribution for identification of the chemical composition of the detected impurity. Using this approach, a number of phosphorothioate impurities can be detected by LC-FTMS including failure sequences carrying 3′-terminal phosphate monoester and 3′-terminal phosphorothioate monoester, incomplete backbone sulfurization and desulfurization products, high molecular weight impurities, and chloral, isobutyryl, and N3 (2-cyanoethyl) adducts

  11. High-resolution Mass Spectrometry of Skin Mucus for Monitoring Physiological Impacts in Fish Exposed to Wastewater Effluent at a Great Lakes AOC

    Science.gov (United States)

    High-resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales promela...

  12. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    Science.gov (United States)

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  13. Utilization of a Si-surface-barrier-detector for alpha-spectrometry and its application in radiation protection for the detection of law alpha-activities

    International Nuclear Information System (INIS)

    Steger, F.; Urbanich, E.; Lovranich, E.; Hefner, A.

    1974-12-01

    Due to the construction of the ''Safeguard Analytical Laboratory''(IAEA), the institute for radiation protection at the Research Center Seibersdorf is interested in a method for the alpha-spectroscopic determination of Pu-239 for personnel and environmental monitoring. Therefore an alpha-spectrometer has been built which will mainly be used for the excretion analysis. The design of the apparatus is described, results of measurements are given and other fields of its application are discussed. (C.R.)

  14. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    Energy Technology Data Exchange (ETDEWEB)

    Katskov, Dmitri, E-mail: katskovda@tut.ac.za

    2015-03-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D{sub 2} and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground

  15. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    International Nuclear Information System (INIS)

    Katskov, Dmitri

    2015-01-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D 2 and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  16. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata, E-mail: bgodlew@uwb.edu.pl

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L{sup −1} HNO{sub 3} solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L{sup −1} and 36.4 mg L{sup −1}, respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93–105% with the repeatability in the range of 4.1–5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg{sup −1}), egg white (2188 ± 29 mg kg{sup −1}), mineral water (31.0 ± 0.9 mg L{sup −1}), white wine (260 ± 4 mg L{sup −1}) and red wine (82 ± 2 mg L{sup −1}), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L{sup −1}). - Highlights: • HR-CS FMAS technique was used for sulfur measurement via molecular absorption of carbon monosulfide, CS. • Organic DL

  17. Efficient high-resolution X-ray emission spectrometry using synchrotron radiation

    International Nuclear Information System (INIS)

    Unterumsberger, Rainer

    2015-01-01

    The aim of the present work is to get access to high-resolution X-Ray Emission Spectrometry (XES) at nanoscaled materials, consisting of light elements and transition metals, by the increase of the sensitivity of a Wavelength-Dispersive Spectrometer (WDS) in the soft X-Ray range. The increase of the sensitivity was achieved by a refocusing of the incident radiation. With the increased sensitivity of the WDS, it was possible to determine the chemical species of different, nominal 100 nm thin titanium oxides. The combination of the refocusing optic and calibrated spectrometer enabled the detection and deconvolution of the L-fluorescence radiation of these nanoscaled titanium oxides. Due to the calibration of the spectrometer, a reliable determination of the transition probabilities of the titanium La- and Ll-fluorescence lines as a function of the chemical state is possible. To the best of my knowledge, the determination of the transition probabilities as a function of the chemical state in the soft X-Ray range has not been investigated yet. The quality of the refocusing was characterized using different diagnostic tools. Vertical full width at half maximum (FWHM) values of the focused beam between 10 μm to 20 μm and horizontal FWHM values between 12 μm and 25 μm could be achieved over an energy range of 180 eV to 1310 eV. Using calibrated photodiodes, it was possible to determine the absolute transmission of the used single bounce monocapillary as well as to monitor the absolute photon flux. By means of the refocusing, it was possible to increase the photon flux by a factor of 4.9 experimentally. The increase of the photon flux enables the analysis of nanoscaled materials with the used spectrometer. This could be shown based on the determination of the lower limit of detection of boron Ka and titanium La. In both cases, the lower limit of detection of 0.4 nm equivalent layer thickness was achieved (about 1.10 -7 g/cm 2 to 2.10 -7 g/cm 2 or 3.10 15 atoms/cm 2 to

  18. Determination of radium isotopes in environmental samples by gamma spectrometry, liquid scintillation counting and alpha spectrometry: a review of analytical methodology

    International Nuclear Information System (INIS)

    Jia, Guogang; Jia, Jing

    2012-01-01

    Radium (Ra) isotopes are important from the viewpoints of radiation protection and environmental protection. Their high toxicity has stimulated the continuing interest in methodology research for determination of Ra isotopes in various media. In this paper, the three most routinely used analytical techniques for Ra isotope determination in biological and environmental samples, i.e. low-background γ-spectrometry, liquid scintillation counting and α-spectrometry, were reviewed, with emphasis on new methodological developments in sample preparation, preconcentration, separation, purification, source preparation and measurement techniques. The accuracy, selectivity, traceability, applicability and minimum detectable activity (MDA) of the three techniques were discussed. It was concluded that the MDA (0.1 mBq L −1 ) of the α-spectrometry technique coupled with chemical separation is about two orders of magnitude lower than that of low-background HPGe γ-spectrometry and LSC techniques. Therefore, when maximum sensitivity is required, the α-spectrometry technique remains the first choice. - Highlights: ► A review is made for determination of Ra isotopes in environmental samples. ► Gamma spectrometry, LSC and a-spectrometry are the main concerned radiometric approach. ► Sample preparation, preconcentration, separation and source preparation are discussed. ► The methods can analyse air, water, seawater, soil, sediment and foodstuffs samples. ► Some new data obtained recently from our laboratory for Ra method study are included.

  19. MASH Suite: a user-friendly and versatile software interface for high-resolution mass spectrometry data interpretation and visualization.

    Science.gov (United States)

    Guner, Huseyin; Close, Patrick L; Cai, Wenxuan; Zhang, Han; Peng, Ying; Gregorich, Zachery R; Ge, Ying

    2014-03-01

    The rapid advancements in mass spectrometry (MS) instrumentation, particularly in Fourier transform (FT) MS, have made the acquisition of high-resolution and high-accuracy mass measurements routine. However, the software tools for the interpretation of high-resolution MS data are underdeveloped. Although several algorithms for the automatic processing of high-resolution MS data are available, there is still an urgent need for a user-friendly interface with functions that allow users to visualize and validate the computational output. Therefore, we have developed MASH Suite, a user-friendly and versatile software interface for processing high-resolution MS data. MASH Suite contains a wide range of features that allow users to easily navigate through data analysis, visualize complex high-resolution MS data, and manually validate automatically processed results. Furthermore, it provides easy, fast, and reliable interpretation of top-down, middle-down, and bottom-up MS data. MASH Suite is convenient, easily operated, and freely available. It can greatly facilitate the comprehensive interpretation and validation of high-resolution MS data with high accuracy and reliability.

  20. Remote sensing of CO2 and CH4 using solar absorption spectrometry with a low resolution spectrometer

    Directory of Open Access Journals (Sweden)

    J. Notholt

    2012-07-01

    Full Text Available Throughout the last few years solar absorption Fourier Transform Spectrometry (FTS has been further developed to measure the total columns of CO2 and CH4. The observations are performed at high spectral resolution, typically at 0.02 cm−1. The precision currently achieved is generally better than 0.25%. However, these high resolution instruments are quite large and need a dedicated room or container for installation. We performed these observations using a smaller commercial interferometer at its maximum possible resolution of 0.11 cm−1. The measurements have been performed at Bremen and have been compared to observations using our high resolution instrument also situated at the same location. The high resolution instrument has been successfully operated as part of the Total Carbon Column Observing Network (TCCON. The precision of the low resolution instrument is 0.32% for XCO2 and 0.46% for XCH4. A comparison of the measurements of both instruments yields an average deviation in the retrieved daily means of ≤0.2% for CO2. For CH4 an average bias between the instruments of 0.47% was observed. For test cases, spectra recorded by the high resolution instrument have been truncated to the resolution of 0.11 cm−1. This study gives an offset of 0.03% for CO2 and 0.26% for CH4. These results indicate that for CH4 more than 50% of the difference between the instruments results from the resolution dependent retrieval. We tentatively assign the offset to an incorrect a-priori concentration profile or the effect of interfering gases, which may not be treated correctly.

  1. A Rough Guide to Metabolite Identification Using High Resolution Liquid Chromatography Mass Spectrometry in Metabolomic Profiling in Metazoans

    Directory of Open Access Journals (Sweden)

    David G Watson

    2013-01-01

    Full Text Available Compound identification in mass spectrometry based metabolomics can be a problem but sometimes the problem seems to be presented in an over complicated way. The current review focuses on metazoans where the range of metabolites is more restricted than for example in plants. The focus is on liquid chromatography with high resolution mass spectrometry where it is proposed that most of the problems in compound identification relate to structural isomers rather than to isobaric compounds. Thus many of the problems faced relate to separation of isomers, which is usually required even if fragmentation is used to support structural identification. Many papers report the use of MS/MS or MS2 as an adjunct to the identification of known metabolites but there a few examples in metabolomics studies of metazoans of complete structure elucidation of novel metabolites or metabolites where no authentic standards are available for comparison.

  2. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Padilla Alvarez, R.; Herrera Peraza, E.

    1997-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA-RX) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G). In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(Li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-Ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively. (author) [es

  3. Distinguishing d- and l-aspartic and isoaspartic acids in amyloid β peptides with ultrahigh resolution ion mobility spectrometry.

    Science.gov (United States)

    Zheng, Xueyun; Deng, Liulin; Baker, Erin S; Ibrahim, Yehia M; Petyuk, Vladislav A; Smith, Richard D

    2017-07-11

    While α-linked amino acids in the l-form are exclusively utilized in mammalian protein building, β-linked and d-form amino acids also have important biological roles. Unfortunately, the structural elucidation and separation of these different amino acid types in peptides has been analytically challenging to date due to the numerous isomers present, limiting our knowledge about their existence and biological roles. Here, we utilized an ultrahigh resolution ion mobility spectrometry platform coupled with mass spectrometry (IMS-MS) to separate amyloid β (Aβ) peptides containing l-aspartic acid, d-aspartic acid, l-isoaspartic acid, and d-isoaspartic acid residues which span α- and β-linked amino acids in both d- and l-forms. The results illustrate how IMS-MS could be used to better understand age-related diseases or protein folding disorders resulting from amino acid modifications.

  4. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Herrera Peraza, E.

    1996-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA R X) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G) In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively

  5. Structural Characterisation of Acetogenins from Annona muricata by Supercritical Fluid Chromatography Coupled to High-Resolution Tandem Mass Spectrometry.

    Science.gov (United States)

    Laboureur, Laurent; Bonneau, Natacha; Champy, Pierre; Brunelle, Alain; Touboul, David

    2017-11-01

    Acetogenins are plant polyketides known to be cytotoxic and proposed as antitumor candidates. They are also suspected to be alimentary neurotoxins. Their occurrence as complex mixtures renders their dereplication and structural identification difficult using liquid chromatography coupled to tandem mass spectrometry and efforts are required to improve the methodology. To develop a supercritical fluid chromatography (SFC) high-resolution tandem mass spectrometry method, involving lithium post-column cationisation, for the structural characterisation of Annonaceous acetogenins in crude extracts. The seeds of Annona muricata L. were extracted with methanol. Supercritical fluid chromatography of the extract, using a 2-ethylpyridine stationary phase column, was monitored using a high-resolution quadrupole time-of-flight mass spectrometer. Lithium iodide was added post-column in the make-up solvent. For comparison, the same extract was analysed using high-pressure liquid chromatography coupled to the same mass spectrometer, with a column based on solid core particles. Sensitivity was similar for both HPLC and SFC approaches. Retention behaviour and fragmentation pathways of three different isomer groups are described. A previously unknown group of acetogenins was also evidenced for the first time. The use of SFC-MS/MS allows the reduction of the time of analysis, of environmental impact and an increase in the chromatographic resolution, compared to liquid chromatography. This new methodology enlightened a new group of acetogenins, isomers of montanacin-D. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in baby food.

    Science.gov (United States)

    Rubert, Josep; James, Kevin J; Mañes, Jordi; Soler, Carla

    2012-02-03

    Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP®) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap®). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP® instrument ranged from 0.45 to 45 μg kg⁻¹ while lower limits of quantification (LLOQs) values were obtained by LTQ-Orbitrap®: 7-70 μg kg⁻¹. The correlation coefficients (r) in both cases were upper than 0.989. These values highlighted that both instruments were complementary for the analysis of mycotoxin in baby food; while QTRAP® reached best sensitivity and selectivity, LTQ-Orbitrap® allowed the identification of non-target and unknowns compounds. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Profiling of modified nucleosides from ribonucleic acid digestion by supercritical fluid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Laboureur, Laurent; Guérineau, Vincent; Auxilien, Sylvie; Yoshizawa, Satoko; Touboul, David

    2018-02-16

    A method based on supercritical fluid chromatography coupled to high resolution mass spectrometry for the profiling of canonical and modified nucleosides was optimized, and compared to classical reverse-phase liquid chromatography in terms of separation, number of detected modified nucleosides and sensitivity. Limits of detection and quantification were measured using statistical method and quantifications of twelve nucleosides of a tRNA digest from E. coli are in good agreement with previously reported data. Results highlight the complementarity of both separation techniques to cover the largest view of nucleoside modifications for forthcoming epigenetic studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Midfrontal Theta and Posterior Parietal Alpha Band Oscillations Support Conflict Resolution in a Masked Affective Priming Task

    Directory of Open Access Journals (Sweden)

    Jun Jiang

    2018-05-01

    Full Text Available Past attempts to characterize the neural mechanisms of affective priming have conceptualized it in terms of classic cognitive conflict, but have not examined the neural oscillatory mechanisms of subliminal affective priming. Using behavioral and electroencephalogram (EEG time frequency (TF analysis, the current study examines the oscillatory dynamics of unconsciously triggered conflict in an emotional facial expressions version of the masked affective priming task. The results demonstrate that the power dynamics of conflict are characterized by increased midfrontal theta activity and suppressed parieto-occipital alpha activity. Across-subject and within-trial correlation analyses further confirmed this pattern. Phase synchrony and Granger causality analyses (GCAs revealed that the fronto-parietal network was involved in unconscious conflict detection and resolution. Our findings support a response conflict account of affective priming, and reveal the role of the fronto-parietal network in unconscious conflict control.

  9. High resolution alpha-autoradiography for measurement of 10B distribution in subcellular scale using CR-39 and AFM

    International Nuclear Information System (INIS)

    Amemiya, K.; Takahashi, H.; Yasuda, N.

    2000-01-01

    In order to measure 10 B distribution in tumor tissues for BNCT at subcellular scale, we have developed a new method for high resolution alpha-autoradiography using contact X-ray microscopy technique with CR-39 plastic track detectors. Sliced sections of boron-injected brain tumors in rats were mounted on CR-39 and irradiated with thermal neutrons at KUR. Then the samples were exposed to soft X-rays from a laser plasma source. After etching the CR-39 in NaOH solution for a short time (1-5 min.), transmission X-ray image of tumor cells appeared as relief on CR-39 surface, and could be observed with the atomic force microscopy (AFM). Very small etch pits of about 100 nm in diameter corresponding to particle tracks from 10 B(n, α) 7 Li reactions were also observed in the image simultaneously. This method provides an accurate distribution of 10 B inside the cell. (author)

  10. Midfrontal Theta and Posterior Parietal Alpha Band Oscillations Support Conflict Resolution in a Masked Affective Priming Task.

    Science.gov (United States)

    Jiang, Jun; Bailey, Kira; Xiao, Xiao

    2018-01-01

    Past attempts to characterize the neural mechanisms of affective priming have conceptualized it in terms of classic cognitive conflict, but have not examined the neural oscillatory mechanisms of subliminal affective priming. Using behavioral and electroencephalogram (EEG) time frequency (TF) analysis, the current study examines the oscillatory dynamics of unconsciously triggered conflict in an emotional facial expressions version of the masked affective priming task. The results demonstrate that the power dynamics of conflict are characterized by increased midfrontal theta activity and suppressed parieto-occipital alpha activity. Across-subject and within-trial correlation analyses further confirmed this pattern. Phase synchrony and Granger causality analyses (GCAs) revealed that the fronto-parietal network was involved in unconscious conflict detection and resolution. Our findings support a response conflict account of affective priming, and reveal the role of the fronto-parietal network in unconscious conflict control.

  11. Expanding the linear dynamic range for quantitative liquid chromatography-high resolution mass spectrometry utilizing natural isotopologue signals

    International Nuclear Information System (INIS)

    Liu, Hanghui; Lam, Lily; Yan, Lin; Chi, Bert; Dasgupta, Purnendu K.

    2014-01-01

    Highlights: • Less abundant isotopologue ions were utilized to decrease detector saturation. • A 25–50 fold increase in the upper limit of dynamic range was demonstrated. • Linear dynamic range was expanded without compromising mass resolution. - Abstract: The linear dynamic range (LDR) for quantitative liquid chromatography–mass spectrometry can be extended until ionization saturation is reached by using a number of target isotopologue ions in addition to the normally used target ion that provides the highest sensitivity. Less abundant isotopologue ions extend the LDR: the lower ion abundance decreases the probability of ion detector saturation. Effectively the sensitivity decreases and the upper limit of the LDR increases. We show in this paper that the technique is particularly powerful with a high resolution time of flight mass spectrometer because the data for all ions are automatically acquired, and we demonstrated this for four small organic molecules; the upper limits of LDRs increased by 25–50 times

  12. High topographic resolution for the study of micro-distribution of alpha-emitters in bones

    International Nuclear Information System (INIS)

    Hanzlik, J.

    1977-10-01

    The project dealt with the method of using dielectric track detectors to determine the micro distribution of bone seekers, particularly radium-226. The bones studied were the mouse femur and vertebrae which were incorporated with radium-226. The preparatory work consisted of a.) preparation of dielectric foils suitable for optimal quantitative alpha autoradiography; b.) preparation of bone sections for such autoradiography; and c.) comparison of various dielectric materials. The autoradiographic method was applied to detect the radium deposition in small localities in bones and in particular, to determine the micro distribution with the aim of establishing a relationship between the incorporated activity and the dose. In evaluating such a relationship, it was concluded that it is essential to take into consideration the density distribution (using the macro method), the concentration gradient in the bands (using the semi micro method) and special track groups (using the micro method). Seven bands were observed characterized by transversal and longitudinal gradients. The transversal concentration gradients are functions of metabolism. The concentration gradients gave information about incorporative trend. Special track groupings indicate the existence of a variable course of repair process

  13. Urinary detection of conjugated and unconjugated anabolic steroids by dilute-and-shoot liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Tudela, Eva; Deventer, Koen; Geldof, Lore; Van Eenoo, Peter

    2015-02-01

    Anabolic androgenic steroids (AAS) are an important class of doping agents. The metabolism of these substances is generally very extensive and includes phase-I and phase-II pathways. In this work, a comprehensive detection of these metabolites is described using a 2-fold dilution of urine and subsequent analysis by liquid chromatography-high resolution mass spectrometry (LC-HRMS). The method was applied to study 32 different metabolites, excreted free or conjugated (glucuronide or sulfate), which permit the detection of misuse of at least 21 anabolic steroids. The method has been fully validated for 21 target compounds (8 glucuronide, 1 sulfate and 12 free steroids) and 18 out of 21 compounds had detection limits in the range of 1-10 ng mL(-1) in urine. For the conjugated compounds, for which no reference standards are available, metabolites were synthesized in vitro or excretion studies were investigated. The detection limits for these compounds ranged between 0.5 and 18 ng mL(-1) in urine. The simple and straightforward methodology complements the traditional methods based on hydrolysis, liquid-liquid extraction, derivatization and analysis by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). Copyright © 2014 John Wiley & Sons, Ltd.

  14. ELM: an Algorithm to Estimate the Alpha Abundance from Low-resolution Spectra

    Science.gov (United States)

    Bu, Yude; Zhao, Gang; Pan, Jingchang; Bharat Kumar, Yerra

    2016-01-01

    We have investigated a novel methodology using the extreme learning machine (ELM) algorithm to determine the α abundance of stars. Applying two methods based on the ELM algorithm—ELM+spectra and ELM+Lick indices—to the stellar spectra from the ELODIE database, we measured the α abundance with a precision better than 0.065 dex. By applying these two methods to the spectra with different signal-to-noise ratios (S/Ns) and different resolutions, we found that ELM+spectra is more robust against degraded resolution and ELM+Lick indices is more robust against variation in S/N. To further validate the performance of ELM, we applied ELM+spectra and ELM+Lick indices to SDSS spectra and estimated α abundances with a precision around 0.10 dex, which is comparable to the results given by the SEGUE Stellar Parameter Pipeline. We further applied ELM to the spectra of stars in Galactic globular clusters (M15, M13, M71) and open clusters (NGC 2420, M67, NGC 6791), and results show good agreement with previous studies (within 1σ). A comparison of the ELM with other widely used methods including support vector machine, Gaussian process regression, artificial neural networks, and linear least-squares regression shows that ELM is efficient with computational resources and more accurate than other methods.

  15. ELM: AN ALGORITHM TO ESTIMATE THE ALPHA ABUNDANCE FROM LOW-RESOLUTION SPECTRA

    International Nuclear Information System (INIS)

    Bu, Yude; Zhao, Gang; Kumar, Yerra Bharat; Pan, Jingchang

    2016-01-01

    We have investigated a novel methodology using the extreme learning machine (ELM) algorithm to determine the α abundance of stars. Applying two methods based on the ELM algorithm—ELM+spectra and ELM+Lick indices—to the stellar spectra from the ELODIE database, we measured the α abundance with a precision better than 0.065 dex. By applying these two methods to the spectra with different signal-to-noise ratios (S/Ns) and different resolutions, we found that ELM+spectra is more robust against degraded resolution and ELM+Lick indices is more robust against variation in S/N. To further validate the performance of ELM, we applied ELM+spectra and ELM+Lick indices to SDSS spectra and estimated α abundances with a precision around 0.10 dex, which is comparable to the results given by the SEGUE Stellar Parameter Pipeline. We further applied ELM to the spectra of stars in Galactic globular clusters (M15, M13, M71) and open clusters (NGC 2420, M67, NGC 6791), and results show good agreement with previous studies (within 1σ). A comparison of the ELM with other widely used methods including support vector machine, Gaussian process regression, artificial neural networks, and linear least-squares regression shows that ELM is efficient with computational resources and more accurate than other methods

  16. ELM: AN ALGORITHM TO ESTIMATE THE ALPHA ABUNDANCE FROM LOW-RESOLUTION SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Bu, Yude [School of Mathematics and Statistics, Shandong University, Weihai, 264209, Shandong (China); Zhao, Gang; Kumar, Yerra Bharat [Key Laboratory for Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing, 100012 (China); Pan, Jingchang, E-mail: ydbu@bao.ac.cn, E-mail: gzhao@nao.cas.cn [School of Mechanical, Electrical and Information Engineering, Shandong University, Weihai, 264209, Shandong (China)

    2016-01-20

    We have investigated a novel methodology using the extreme learning machine (ELM) algorithm to determine the α abundance of stars. Applying two methods based on the ELM algorithm—ELM+spectra and ELM+Lick indices—to the stellar spectra from the ELODIE database, we measured the α abundance with a precision better than 0.065 dex. By applying these two methods to the spectra with different signal-to-noise ratios (S/Ns) and different resolutions, we found that ELM+spectra is more robust against degraded resolution and ELM+Lick indices is more robust against variation in S/N. To further validate the performance of ELM, we applied ELM+spectra and ELM+Lick indices to SDSS spectra and estimated α abundances with a precision around 0.10 dex, which is comparable to the results given by the SEGUE Stellar Parameter Pipeline. We further applied ELM to the spectra of stars in Galactic globular clusters (M15, M13, M71) and open clusters (NGC 2420, M67, NGC 6791), and results show good agreement with previous studies (within 1σ). A comparison of the ELM with other widely used methods including support vector machine, Gaussian process regression, artificial neural networks, and linear least-squares regression shows that ELM is efficient with computational resources and more accurate than other methods.

  17. Topoisomerase 3alpha and RMI1 suppress somatic crossovers and are essential for resolution of meiotic recombination intermediates in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Frank Hartung

    2008-12-01

    Full Text Available Topoisomerases are enzymes with crucial functions in DNA metabolism. They are ubiquitously present in prokaryotes and eukaryotes and modify the steady-state level of DNA supercoiling. Biochemical analyses indicate that Topoisomerase 3alpha (TOP3alpha functions together with a RecQ DNA helicase and a third partner, RMI1/BLAP75, in the resolution step of homologous recombination in a process called Holliday Junction dissolution in eukaryotes. Apart from that, little is known about the role of TOP3alpha in higher eukaryotes, as knockout mutants show early lethality or strong developmental defects. Using a hypomorphic insertion mutant of Arabidopsis thaliana (top3alpha-2, which is viable but completely sterile, we were able to define three different functions of the protein in mitosis and meiosis. The top3alpha-2 line exhibits fragmented chromosomes during mitosis and sensitivity to camptothecin, suggesting an important role in chromosome segregation partly overlapping with that of type IB topoisomerases. Furthermore, AtTOP3alpha, together with AtRECQ4A and AtRMI1, is involved in the suppression of crossover recombination in somatic cells as well as DNA repair in both mammals and A. thaliana. Surprisingly, AtTOP3alpha is also essential for meiosis. The phenotype of chromosome fragmentation, bridges, and telophase I arrest can be suppressed by AtSPO11 and AtRAD51 mutations, indicating that the protein is required for the resolution of recombination intermediates. As Atrmi1 mutants have a similar meiotic phenotype to Attop3alpha mutants, both proteins seem to be involved in a mechanism safeguarding the entangling of homologous chromosomes during meiosis. The requirement of AtTOP3alpha and AtRMI1 in a late step of meiotic recombination strongly hints at the possibility that the dissolution of double Holliday Junctions via a hemicatenane intermediate is indeed an indispensable step of meiotic recombination.

  18. Fluorine determination in coal using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Patrícia M.; Morés, Silvane; Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Welz, Bernhard, E-mail: w.bernardo@terra.com.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil); Carasek, Eduardo [Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq, INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115 Salvador, BA (Brazil)

    2015-03-01

    The absorption of the calcium mono-fluoride (CaF) molecule has been employed in this study for the determination of fluorine in coal using direct solid sample analysis and high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS). The rotational line at 606.440 nm was used for measuring the molecular absorption in the gas phase. The pyrolysis and vaporization temperatures were 700 °C and 2100 °C, respectively. Different chemical modifiers have been studied, such as Pd and Ir as permanent modifiers, and Pd and the mixed Pd/Mg modifier in solution. The limit of detection and the characteristic mass were 0.3 and 0.1 ng F, respectively. One certified reference material (CRM) of coal (NIST 1635) and four CRMs with a non-certified value for F (SARM 18, SARM 20, BCR 40, BCR 180) were used to evaluate the accuracy and precision of the method, obtaining good agreement (104%) with the certified value and with the informed values (ranging from 90 to 103%). - Highlights: • High-resolution Graphite Furnace Molecular Absorption Spectrometry (HR-GF MAS) • Fluorine has been determined using HR-GF MAS of the CaF molecule. • The CaF molecule was generated in a graphite furnace at a temperature of 2100 °C • Coal samples have been analyzed using direct solid sample introduction. • Aqueous standard solutions have been used for calibration.

  19. Molecular characterization of phytoplankton dissolved organic matter (DOM) and sulfur components using high resolution Orbitrap mass spectrometry.

    Science.gov (United States)

    Mangal, Vaughn; Stock, Naomi L; Guéguen, Celine

    2016-03-01

    Orbitrap high resolution mass spectrometry (HRMS) with electrospray ionization in both positive and negative polarity was conducted on Suwannee River fulvic acid (SRFA), Pony Lake fulvic acid (PLFA) standards, and dissolved organic matter (DOM) released by freshwater phytoplankton (Scenedesmus obliquus, Euglena mutabilis, and Euglena gracilis). Three-dimensional van Krevelen diagrams expressing various oxygenation states of sulfur molecules and abundance plots of sulfur-containing species were constructed. Orbitrap HRMS analysis of SRFA found a high density of peaks in the lignin region (77 %) and low density of protein material (6.53 %), whereas for PLFA, 25 % of the total peaks were lignin related compared to 56 % of peaks in protein regions, comparable with other HRMS studies. Phytoplankton-derived DOM of S. obliquus, E. mutabilis, and E. gracilis was dominated by protein molecules at respective percentages of 36, 46, and 49 %, and is consistent with previous experiments examining phytoplankton-derived DOM composition. The normalized percentage of SO-containing compounds was determined among the three phytoplankton to be 56 % for Scenedesmus, 54 % for E. mutabilis, and 47 % for E. gracilis, suggesting variation between sulfur content in phytoplankton-derived DOM and differences in metal binding capacities. These results suggest the level of resolution by Orbitrap mass spectrometry is sufficient for preliminary characterization of phytoplankton DOM at an affordable cost relative to other HRMS techniques.

  20. Desorption atmospheric pressure photoionization high-resolution mass spectrometry: a complementary approach for the chemical analysis of atmospheric aerosols.

    Science.gov (United States)

    Parshintsev, Jevgeni; Vaikkinen, Anu; Lipponen, Katriina; Vrkoslav, Vladimir; Cvačka, Josef; Kostiainen, Risto; Kotiaho, Tapio; Hartonen, Kari; Riekkola, Marja-Liisa; Kauppila, Tiina J

    2015-07-15

    On-line chemical characterization methods of atmospheric aerosols are essential to increase our understanding of physicochemical processes in the atmosphere, and to study biosphere-atmosphere interactions. Several techniques, including aerosol mass spectrometry, are nowadays available, but they all suffer from some disadvantages. In this research, desorption atmospheric pressure photoionization high-resolution (Orbitrap) mass spectrometry (DAPPI-HRMS) is introduced as a complementary technique for the fast analysis of aerosol chemical composition without the need for sample preparation. Atmospheric aerosols from city air were collected on a filter, desorbed in a DAPPI source with a hot stream of toluene and nitrogen, and ionized using a vacuum ultraviolet lamp at atmospheric pressure. To study the applicability of the technique for ambient aerosol analysis, several samples were collected onto filters and analyzed, with the focus being on selected organic acids. To compare the DAPPI-HRMS data with results obtained by an established method, each filter sample was divided into two equal parts, and the second half of the filter was extracted and analyzed by liquid chromatography/mass spectrometry (LC/MS). The DAPPI results agreed with the measured aerosol particle number. In addition to the targeted acids, the LC/MS and DAPPI-HRMS methods were found to detect different compounds, thus providing complementary information about the aerosol samples. DAPPI-HRMS showed several important oxidation products of terpenes, and numerous compounds were tentatively identified. Thanks to the soft ionization, high mass resolution, fast analysis, simplicity and on-line applicability, the proposed methodology has high potential in the field of atmospheric research. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Electron energy-loss spectrometry at the frontier of spatial and energy resolution

    International Nuclear Information System (INIS)

    Hofer, F.; Grogger, W.; Kothleitner, G.

    2004-01-01

    Full text: Electron energy-loss spectroscopy (EELS) in the transmission electron microscope (TEM) is now used routinely as a means of measuring chemical and structural properties of very small regions of a thin specimen. The power of this technique depends significantly on two parameters: its spatial resolution and the energy resolution available in the spectrum and in the energy-filtered TEM (EFTEM) image. The cold field emission source and the Schottky emitter have made an energy resolution below 1 eV possible and it is now feasible to obtain data with a spatial resolution close to atomic dimensions, given the right instrumentation and specimen. EFTEM allows to record elemental maps at sub-nanometre resolution, being mainly limited by chromatic and spherical aberration of the objective lens and by delocalization of inelastic scattering. Recently the possibility of correcting spherical and even chromatic aberrations of electron lenses has become a practical reality thus improving the point resolution of the TEM to below 0.1 nm. The other limiting factor for EFTEM resolution is delocalization. However, recent measurements show that resolution values in the range of 1 nm and below can be achieved, even for energy-losses of only a few eV. In terms of energy-resolution, EELS and EFTEM compare less favourably with other spectroscopies. For common TEMs, the overall energy-resolution is mainly determined by the energy width of the electron source, typically between 0.5 and 1.5 eV. For comparison, synchrotron x-ray sources and beam line spectrometers, provide a resolution well below 0.1 eV for absorption spectroscopy. During the early sixties, the energy spread of an electron beam could be reduced by incorporating an energy-filter into the illumination system, but the system lacked spatial resolution. Later developments combined high energy resolution in the range of 0.1 eV with improved spatial resolution. Recently, FEI introduced a new high resolution EELS system based

  2. Classification of wine by determination of bioactive phenolic compounds using high resolution mass spectrometry

    OpenAIRE

    Ivanova, Violeta; Dimovska, Violeta; Mitrev, Sasa; Gulaboski, Rubin; Bogeva, Elena; Petruseva, Dragana; Causon, Tim; Hann, Stephan

    2016-01-01

    In this project proposal, metabolomic fingerprinting of wine samples will be examined using high performance liquid chromatography combined with ion mobility quadruple time-of-flight mass spectrometry (HPLC–IMS-QTOF-MS) for the first time. Bioactive compounds in wines from various red and white varieties produced in Macedonia and Austria from different wine regions and different vintages will be determined for the first time using a non-targeted fingerprinting approach on this analytical plat...

  3. Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry

    Science.gov (United States)

    Mahmoodani, Fatemeh; Perera, Conrad O.; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong

    2018-03-01

    In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MSn) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. [Figure not available: see fulltext.

  4. Protein hydrogen exchange measured at single-residue resolution by electron transfer dissociation mass spectrometry

    DEFF Research Database (Denmark)

    Rand, Kasper D; Zehl, Martin; Jensen, Ole Nørregaard

    2009-01-01

    Because of unparalleled sensitivity and tolerance to protein size, mass spectrometry (MS) has become a popular method for measuring the solution hydrogen (1H/2H) exchange (HX) of biologically relevant protein states. While incorporated deuterium can be localized to different regions by pepsin....... The deuterium labeling pattern of beta2-microglobulin is retained in the gaseous fragment ions by employing mild declustering conditions for electrospray ionization. A recently developed model peptide is used to arrive at such ion source declustering conditions that prevent the occurrence of intramolecular gas...

  5. Boron concentration measurements by alpha spectrometry and quantitative neutron autoradiography in cells and tissues treated with different boronated formulations and administration protocols

    International Nuclear Information System (INIS)

    Bortolussi, Silva; Ciani, Laura; Postuma, Ian; Protti, Nicoletta; Luca Reversi,; Bruschi, Piero; Ferrari, Cinzia; Cansolino, Laura; Panza, Luigi; Ristori, Sandra; Altieri, Saverio

    2014-01-01

    The possibility to measure boron concentration with high precision in tissues that will be irradiated represents a fundamental step for a safe and effective BNCT treatment. In Pavia, two techniques have been used for this purpose, a quantitative method based on charged particles spectrometry and a boron biodistribution imaging based on neutron autoradiography. A quantitative method to determine boron concentration by neutron autoradiography has been recently set-up and calibrated for the measurement of biological samples, both solid and liquid, in the frame of the feasibility study of BNCT. This technique was calibrated and the obtained results were cross checked with those of α spectrometry, in order to validate them. The comparisons were performed using tissues taken form animals treated with different boron administration protocols. Subsequently the quantitative neutron autoradiography was employed to measure osteosarcoma cell samples treated with BPA and with new boronated formulations. - Highlights: • A method for 10B measurements in samples based on neutron autoradiography was developed. • The results were compared with those of alpha spectrometry applied on tissue and cell samples. • Boronated liposomes were developed and administered to osteosarcoma cell cultures. • Neutron autoradiography was employed to measure boron concentration due to liposomes. • Liposomes were proved to be more effective in concentrating boron in cells than BPA

  6. Development of an improved high resolution mass spectrometry based multi-residue method for veterinary drugs in various food matrices.

    Science.gov (United States)

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2011-08-26

    Multi-residue methods for veterinary drugs or pesticides in food are increasingly often based on ultra performance liquid chromatography (UPLC) coupled to high resolution mass spectrometry (HRMS). Previous available time of flight (TOF) technologies, showing resolutions up to 15,000 full width at half maximum (FWHM), were not sufficiently selective for monitoring low residue concentrations in difficult matrices (e.g. hormones in tissue or antibiotics in honey). The approach proposed in this paper is based on a single stage Orbitrap mass spectrometer operated at 50,000 FWHM. Extracts (liver and kidney) which were produced according to a validated multi-residue method (time of flight detection based) could not be analyzed by Orbitrap because of extensive signal suppression. This required the improvement of established extraction and clean-up procedures. The introduced, more extensive deproteinzation steps and dedicated instrumental settings successfully eliminated these detrimental suppression effects. The reported method, covering more than 100 different veterinary dugs, was validated according to the EU Commission Decision 2002/657/EEC. Validated matrices include muscle, kidney, liver, fish and honey. Significantly better performance parameters (e.g. linearity, reproducibility and detection limits) were obtained when comparing the new method with the older, TOF based method. These improvements are attributed to the higher resolution (50,000 versus 12,000 FWHM) and the superior mass stability of the of the Orbitrap over the previously utilized TOF instrument. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. A fragmentation study of kaempferol using electrospray quadrupole time-of-flight mass spectrometry at high mass resolution

    Science.gov (United States)

    March, Raymond E.; Miao, Xiu-Sheng

    2004-02-01

    A mass spectrometric method based on the combined use of electrospray ionization, collision-induced dissociation and tandem mass spectrometry at high mass resolution has been applied to an investigation of the structural characterization of protonated and deprotonated kaempferol (3,5,7,4'-tetrahydroxyflavone). Low-energy product ion mass spectra of [M+H]+ ions showed simple fragmentations of the C ring that permitted characterization of the substituents in the A and B rings. In addition, four rearrangement reactions accompanied by losses of C2H2O, CHO[radical sign], CO, and H2O were observed. Low-energy product ion mass spectra of [M-H]- ions showed only four rearrangement reactions accompanied by losses of OH[radical sign], CO, CH2O, and C2H2O. The use of elevated cone voltages permitted observation of product ion mass spectra of selected primary and secondary fragment ions so that each fragment ion reported was observed as a direct product of its immediate precursor ion. Product ion mass spectra examined at high mass resolution allowed unambiguous determination of the elemental composition of fragment ions and resolution of two pairs of isobars. Fragmentation mechanisms and ion structures have been proposed.

  8. Standard guide for high-resolution gamma-ray spectrometry of soil samples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers the identification and quantitative determination of gamma-ray emitting radionuclides in soil samples by means of gamma-ray spectrometry. It is applicable to nuclides emitting gamma rays with an approximate energy range of 20 to 2000 keV. For typical gamma-ray spectrometry systems and sample types, activity levels of about 5 Bq (135 pCi) are measured easily for most nuclides, and activity levels as low as 0.1 Bq (2.7 pCi) can be measured for many nuclides. It is not applicable to radionuclides that emit no gamma rays such as the pure beta-emitting radionuclides hydrogen-3, carbon-14, strontium-90, and becquerel quantities of most transuranics. This guide does not address the in situ measurement techniques, where soil is analyzed in place without sampling. Guidance for in situ techniques can be found in Ref (1) and (2). This guide also does not discuss methods for determining lower limits of detection. Such discussions can be found in Refs (3), (4), (5), and (6). 1.2 This guide can be us...

  9. Measuring the hydrogen/deuterium exchange of proteins at high spatial resolution by mass spectrometry

    DEFF Research Database (Denmark)

    Rand, Kasper Dyrberg; Zehl, Martin; Jørgensen, Thomas J D

    2014-01-01

    , and eventually all of the protecting hydrogen bonds will transiently break as the protein-according to thermodynamic principles-cycles through partially unfolded states that correspond to excited free energy levels. As a result, all of the backbone amides will eventually become temporarily solvent....../dysfunction and conformational dynamics requires in many cases higher resolution and ultimately single-residue resolution. In this Account, we summarize our efforts to achieve single-residue deuterium levels in proteins by electron-based or laser-induced gas-phase fragmentation methods. A crucial analytical requirement...

  10. Bayesian approach to peak deconvolution and library search for high resolution gas chromatography - Mass spectrometry

    NARCIS (Netherlands)

    Barcaru, A.; Mol, H.G.J.; Tienstra, M.; Vivó-Truyols, G.

    2017-01-01

    A novel probabilistic Bayesian strategy is proposed to resolve highly coeluting peaks in high-resolution GC-MS (Orbitrap) data. Opposed to a deterministic approach, we propose to solve the problem probabilistically, using a complete pipeline. First, the retention time(s) for a (probabilistic) number

  11. Application of spatially resolved high resolution crystal spectrometry to inertial confinement fusion plasmas.

    Science.gov (United States)

    Hill, K W; Bitter, M; Delgado-Aparacio, L; Pablant, N A; Beiersdorfer, P; Schneider, M; Widmann, K; Sanchez del Rio, M; Zhang, L

    2012-10-01

    High resolution (λ∕Δλ ∼ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-μm (55)Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10(-8)-10(-6) times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

  12. Near-optimum procedure for half-life measurement by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Parker, J.L.

    1989-01-01

    A near-optimum procedure for using high-resolution γ-ray spectrometry to measure the half-lives of appropriate γ-ray- emitting-nuclides is presented. Among the important points of the procedure are the employment of the reference source method for implicit correction of pileup and deadtime losses; the use of full-energy peak-area ratios as the fundamental measured quantities; and continuous, high-rate data acquisition to obtain good results in a fraction of a half-life if desired. Equations are given for estimating the precision of the computed half-lives in terms of total measurement time, number of spectral acquisitions, and the precision of peak-area ratios. Results of 169 Yb half-life measurements are given as an example of the procedure's application. 3 refs., 2 tabs

  13. Identification of the Related Substances in Ampicillin Capsule by Rapid Resolution Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2014-01-01

    Full Text Available Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MSn was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmentation behaviors, retention time, and chemical structures in the literature. This study avoided time-consuming and complex chemosynthesis of related substances of ampicillin and the results could be useful for the quality control of ampicillin capsule to guarantee its safety in clinic. In the meantime, it provided a good example for the rapid identification of chemical structures of related substances of drugs.

  14. Elemental Composition Analysis to Investigate NOx Effects on Secondary Organic Aerosol from α-Pinene Using Ultrahigh Resolution Mass Spectrometry

    Science.gov (United States)

    Lim, H. J.; Park, J. H.; Babar, Z.

    2015-12-01

    Secondary organic aerosol (SOA) accounts for 20-70% of atmospheric fine aerosol. NOx plays crucial roles in SOA formation and consequently affects the composition and yield of SOA. SOA component speciation is incomplete due to its complex composition of polar oxygenated and multifunctional species. In this study, ultrahigh resolution mass spectrometry (UHR MS) was applied to improve the understanding of NOx effects on biogenic SOA formation by identifying the elemental composition of SOA. Additional research aim was to investigate oligomer components that are considered as a driving force for SOA formation and growth. In this study α-pinene SOA from photochemical reaction was examined. SOA formation was performed in the absence and presence of NOx at dry condition (grant funded by the Korea government (MEST) (No. 2011-01350000).

  15. First characterization of AKB-48 metabolism, a novel synthetic cannabinoid, using human hepatocytes and high-resolution mass spectrometry.

    Science.gov (United States)

    Gandhi, Adarsh S; Zhu, Mingshe; Pang, Shaokun; Wohlfarth, Ariane; Scheidweiler, Karl B; Liu, Hua-Fen; Huestis, Marilyn A

    2013-10-01

    Since the federal authorities scheduled the first synthetic cannabinoids, JWH-018 and JWH-073, new synthetic cannabinoids were robustly marketed. N-(1-Adamantyl)-1-pentylindazole-3-carboxamide (AKB-48), also known as APINACA, was recently observed in Japanese herbal smoking blends. The National Forensic Laboratory Information System registered 443 reports of AKB-48 cases in the USA from March 2010 to January 2013. In May 2013, the Drug Enforcement Administration listed AKB-48 as a Schedule I drug. Recently, AKB-48 was shown to have twice the CB1 receptor binding affinity than CB2. These pharmacological effects and the difficulty in detecting the parent compound in urine highlight the importance of metabolite identification for developing analytical methods for clinical and forensic investigations. Using human hepatocytes and TripleTOF mass spectrometry, we identified 17 novel phase I and II AKB-48 metabolites, products of monohydroxylation, dihydroxylation, or trihydroxylation on the aliphatic adamantane ring or N-pentyl side chain. Glucuronide conjugation of some mono- and dihydroxylated metabolites also occurred. Oxidation and dihydroxylation on the adamantane ring and N-pentyl side chain formed a ketone. More metabolites were identified after 3 h of incubation than at 1 h. For the first time, we present a AKB-48 metabolic scheme obtained from human hepatocytes and high-resolution mass spectrometry. These data are needed to develop analytical methods to identify AKB-48 consumption in clinical and forensic testing.

  16. Evaluation and optimization of high-performance liquid chromatography coupled with high-resolution mass spectrometry for phospholipid quantitation.

    Science.gov (United States)

    Fu, Mingkun; Xu, Wei; Lu, Qing; Pan, Guoyu; Varga, Csanad

    2014-04-15

    High-performance liquid chromatography coupled with high-resolution mass spectrometry (HPLC/HRMS) provides an attractive alternative to the traditional triple quadrupole mass spectrometry selected reaction monitoring (SRM) methodology in the field of quantitation. An LTQ Orbitrap Velos mass spectrometer coupled with a Shimadzu UHPLC system was used. A mass extraction window (MEW) was defined to mathematically correlate with mass resolving power (MRP). Five MRP measurement conditions at 7500, 15,000, 30,000, 60,000, and 100,000, and five MEW widths at 10%, 20%, 50%, and 100% of ±1000000/MRP, and were utilized as the experimental conditions. Comparison of profile and centroid algorithms was evaluated as well. Selection of pH 8.5 buffer, C4 column, 20% IPA, and 10 ppm H3 PO4 , minimized hydrophobic and silanol interactions to enhance separation. Narrowing the MEW minimized background noise, while over-narrowing the MEW gave signal loss due to mass accuracy deviation. The mass accuracy deviation was larger for lower MRP measurements especially with centriod data, and hence a profile algorithm was recommended. The post-ionization signal suppression was observed with low MRP and was further confirmed with the analysis of multi-level linearity. It was found that the HPLC/HRMS method with conditions of 20% ±1000000/MRP as MEW, 30,000 or 60,000 MRP, and profile algorithm, provide optimum results for quantitation of seven model phospholipids. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Discovery of putative salivary biomarkers for Sjögren's syndrome using high resolution mass spectrometry and bioinformatics.

    Science.gov (United States)

    Zoukhri, Driss; Rawe, Ian; Singh, Mabi; Brown, Ashley; Kublin, Claire L; Dawson, Kevin; Haddon, William F; White, Earl L; Hanley, Kathleen M; Tusé, Daniel; Malyj, Wasyl; Papas, Athena

    2012-03-01

    The purpose of the current study was to determine if saliva contains biomarkers that can be used as diagnostic tools for Sjögren's syndrome (SjS). Twenty seven SjS patients and 27 age-matched healthy controls were recruited for these studies. Unstimulated glandular saliva was collected from the Wharton's duct using a suction device. Two µl of salvia were processed for mass spectrometry analyses on a prOTOF 2000 matrix-assisted laser desorption/ionization orthogonal time of flight (MALDI O-TOF) mass spectrometer. Raw data were analyzed using bioinformatic tools to identify biomarkers. MALDI O-TOF MS analyses of saliva samples were highly reproducible and the mass spectra generated were very rich in peptides and peptide fragments in the 750-7,500 Da range. Data analysis using bioinformatic tools resulted in several classification models being built and several biomarkers identified. One model based on 7 putative biomarkers yielded a sensitivity of 97.5%, specificity of 97.8% and an accuracy of 97.6%. One biomarker was present only in SjS samples and was identified as a proteolytic peptide originating from human basic salivary proline-rich protein 3 precursor. We conclude that salivary biomarkers detected by high-resolution mass spectrometry coupled with powerful bioinformatic tools offer the potential to serve as diagnostic/prognostic tools for SjS.

  18. Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers

    Science.gov (United States)

    Abad, Carlos; Florek, Stefan; Becker-Ross, Helmut; Huang, Mao-Dong; Heinrich, Hans-Joachim; Recknagel, Sebastian; Vogl, Jochen; Jakubowski, Norbert; Panne, Ulrich

    2017-10-01

    Boron isotope amount ratios n(10B)/n(11B) have been determined by monitoring the absorption spectrum of boron monohydride (BH) in a graphite furnace using high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Bands (0 → 0) and (1 → 1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Clean and free of memory effect molecular spectra of BH were recorded. In order to eliminate the memory effect of boron, a combination of 2% (v/v) hydrogen gas in argon and 1% trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers was used. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, for the evaluated region of 437 nm, an accuracy of 0.15‰ is obtained as the average deviation from the isotope reference materials. Expanded uncertainties with a coverage factor of k = 2 range between 0.15 and 0.44‰. This accuracy and precision are compatible with those obtained by mass spectrometry for boron isotope ratio measurements.

  19. The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cho, Sung-Hee; Lee, Sun-Kyung; Kim, Chong Hyeak

    2018-05-01

    Polycyclic aromatic hydrocarbons (PAHs), organic compounds formed by at least two condensed aromatic rings, are ubiquitous environmental pollutants that are produced by incomplete combustion of organic materials. PAHs have been classified as carcinogenIC to humans by the International Agency for Research on Cancer, because they can bind to DNA, causing mutations. Therefore, the levels of PAHs in human urine can be used as an indicator for potential carcinogenesis and cell mutation. An analytical method was developed for the accurate measurement of PAHs in urine using high-resolution gas chromatography-mass spectrometry. Urine samples were extracted by an Oasis HLB extraction cartridge after enzymatic hydrolysis with a β-glucuronidase/arylsulfatase cocktail. The 18 PAHs were separated using an Agilent DB-5 MS capillary column (30 m × 0.25 mm, 0.25 μm) and monitored by time-of-flight mass spectrometry. Under the optimized method, the linearity of calibration curves was >0.994. The limits of detection at a signal-to-noise ratio of 3 were 10-100 ng/L. The coefficients of variation were in the range of 0.4-9.0%. The present method was highly accurate for simultaneous determination of 18 PAHs in human urine and could be applied to monitoring and biomedical investigations to check exposure of PAHs. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Data on endogenous bovine ovarian follicular cells peptides and small proteins obtained through Top-down High Resolution Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Valérie Labas

    2017-08-01

    Full Text Available The endogenous peptides and small proteins extracted from bovine ovarian follicular cells (oocytes, cumulus and granulosa cells were identified by Top-down High Resolution Mass Spectrometry (TD-HR-MS/MS in order to annotate peptido- and proteoforms detected using qualitative and quantitative profiling method based on ICM-MS (Intact Cell Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. The description and analysis of these Top-down MS data in the context of oocyte quality biomarkers research are available in the original research article of Labas et al. (2017 http://dx.doi.org/10.1016/j.jprot.2017.03.027 [1]. Raw data derived from this peptidomic/proteomic analysis have been deposited to the ProteomeXchange Consortium via the PRIDE partner repository (dataset identifier PXD004892. Here, we described the inventory of all identified peptido- and proteoforms including their biochemical and structural features, and functional annotation of correspondent proteins. This peptide/protein inventory revealed that TD-HR-MS/MS was appropriate method for both global and targeted proteomic analysis of ovarian tissues, and it can be further employed as a reference for other studies on follicular cells including single oocytes.

  1. Use of a Shielded High Resolution Gamma Spectrometry System to Segregate LLW from Contact Handleable ILW Containing Plutonium - 13046

    Energy Technology Data Exchange (ETDEWEB)

    Lester, Rosemary; Wilkins, Colin [Canberra UK Ltd, Unit 1 B528.1, Harwell Science Campus, Oxfordshire OX11 0DF (United Kingdom); Chard, Patrick [Canberra UK Ltd, Forss Business and Technology park, Thurso, Caithness KW14 7UZ (United Kingdom); Jaederstroem, Henrik; LeBlanc, Paul; Mowry, Rick [Canberra Industries, Inc., 800 Research Parkway, Meriden, Connecticut, 06450 (United States); MacDonald, Sanders; Gunn, William [Dounreay Site Restoration Limited, Dounreay, Thurso, Caithness, KW14 7TZ (United Kingdom)

    2013-07-01

    Dounreay Site Restoration Limited (DSRL) have a number of drums of solid waste that may contain Plutonium Contaminated Material. These are currently categorised as Contact Handleable Intermediate Level Waste (CHILW). A significant fraction of these drums potentially contain waste that is in the Low Level Waste (LLW) category. A Canberra Q2 shielded high resolution gamma spectrometry system is being used to quantify the total activity of drums that are potentially in the LLW category in order to segregate those that do contain LLW from CHILW drums and thus to minimise the total volume of waste in the higher category. Am-241 is being used as an indicator of the presence of plutonium in the waste from its strong 59.54 keV gamma-ray; a knowledge of the different waste streams from which the material originates allows a pessimistic waste 'fingerprint' to be used in order to determine an upper limit to the activities of the weak and non-gamma-emitting plutonium and associated radionuclides. This paper describes the main features of the high resolution gamma spectrometry system being used by DSRL to perform the segregation of CHILW and LLW and how it was configured and calibrated using the Canberra In-Situ Object Counting System (ISOCS). It also describes how potential LLW drums are selected for assay and how the system uses the existing waste stream fingerprint information to determine a reliable upper limit for the total activity present in each measured drum. Results from the initial on-site commissioning trials and the first measurements of waste drums using the new monitor are presented. (authors)

  2. Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Dreyer, Jonathan G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wang, Tzu-Fang [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Vo, Duc T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Funk, Pierre F. [Inst. for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses (France); Weber, Anne-Laure [Inst. for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses (France)

    2017-07-20

    Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

  3. Burn-Up Determination by High Resolution Gamma Spectrometry: Fission Product Migration Studies

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, R S; Blackadder, W H; Ronqvist, N

    1967-04-15

    The migration of solid fission products, in particular caesium and ruthenium, in high temperature oxide fuel can create a severe problem during the application of non-destructive burn-up methods employing gamma spectrometry, since caesium-137 is otherwise the most convenient long-lived burn-up monitor and ruthenium-106 can be used to distinguish between fissions in U-235 and Pu-239. As part of an experimental programme to develop burn-up methods, gamma scanning experiments have been performed on slices of irradiated UO{sub 2} pellets using a lithium-drifted germanium detector. The usefulness of the technique for migration studies has been demonstrated by comparing the fission product distribution curves across the specimen diameters with the microstructure of the specimens after polishing and etching.

  4. Site-specific glycosylation of donkey milk lactoferrin investigated by high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Gallina, Serafina; Saletti, Rosaria; Cunsolo, Vincenzo

    2016-01-01

    A comprehensive monosaccharide composition of the N-glycans of donkey milk lactoferrin, isolated by ion exchange chromatography from an individual milk sample, was obtained by means of chymotryptic digestion, TiO2 and HILIC enrichment, reversed-phase high-performance liquid chromatography......, electrospray mass spectrometry, and high collision dissociation fragmentation. The results obtained allowed identifying 26 different glycan structures, including high mannose, complex and hybrid N-glycans, linked to the protein backbone via an amide bond to asparagine residues located at the positions 137, 281...... and 476. Altogether, the N-glycan structures determined revealed that most of the N-glycans identified in donkey milk lactoferrin are neutral complex/hybrid. Indeed, 10 neutral non-fucosylated complex/hybrid N-glycans and 4 neutral fucosylated complex/hybrid N-glycans were found. In addition, two high...

  5. Ultra High-Mass Resolution Paper Spray by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kevin D. Quinn

    2012-01-01

    Full Text Available Paper Spray Ionization is an atmospheric pressure ionization technique that utilizes an offline electro-osmotic flow to generate ions off a paper medium. This technique can be performed on a Bruker SolariX Fourier transform ion cyclotron resonance mass spectrometer by modifying the existing nanospray source. High-resolution paper spray spectra were obtained for both organic and biological samples to demonstrate the benefit of linking the technique with a high-resolution mass analyzer. Error values in the range 0.23 to 2.14 ppm were obtained for calf lung surfactant extract with broadband mass resolving power (m/Δm50% above 60,000 utilizing an external calibration standard.

  6. Application of MALDI-TOF mass spectrometry for study on fibrillar and oligomeric aggregates of alpha-synuclein

    NARCIS (Netherlands)

    Severinovskaya, O. V.; Kovalska, V B; Losytskyy, M Yu; Cherepanov, V. V.; Subramaniam, V.; Yarmoluk, S M

    2014-01-01

    Aim. To study the α-synuclein (ASN) aggregates of different structural origin, namely amyloid fibrils and spherical oligomers, in comparison with a native protein. Methods. MALDI TOF mass spectrometry and atomic force microscopy (AFM). Results. The mass spectra of native and fibrillar ASN have

  7. Implantation of alpha spectrometry methodology for the determination of U and Th isotopes in igneous rocks: application to the study of radioactive desequilibrium in the Trindade Island, Brazil

    International Nuclear Information System (INIS)

    Santos, Rosana Nunes dos

    2001-01-01

    This work describes the implementation of experimental procedures for alpha spectrometry measurement of 238 U, 234 U and 230 Th activities in silicates. The best experimental conditions were defined using 233 U, 232 U and 229 Th radioactive tracers and simulating the usual conditions found in processing silicates. The chemical procedures consists of the following steps: radioactive tracer addition and sample dissolution by acid digestion, U and Th pre-concentration by co-precipitation, element separation and purification by ion exchange chromatography and electrodeposition in inox steel disks. In order to evaluate its effectiveness, the procedure was applied to the Brazilian geological standards BB-1 (basalt) and GB-1 (granite). The obtained chemical yields for uranium and thorium are of about 60% and 70%, respectively, for both matrices. The described methodology furnishes activity measurements with less than 4% relative precision and accuracies of about 1%, that are essential for petrogenetic applications. The 238 U and 232 Th series disequilibrium conditions were investigated by alpha spectrometry, together with neutron activation analysis and natural gamma-ray spectrometry. 234 U/ 238 U, 238 U/ 232 Th and 230 Th/ 232 Th activity ratios and the 234 Th, 214 Pb, 214 Bi, 235 U, 228 Ac, 212 Pb, 212 Bi and 208 Tl specific activities were obtained. These results were interpreted with the help of additional constraints given by the larger and smaller elements concentrations, measured by X-ray fluorescence. The 232 Th series is in secular radioactive equilibrium in all analysed samples. In the case of the 238 U series, the equilibrium condition was verified, as expected, in the oldest rocks from the Trindade Island (Trindade Complex and Desejado Sequence). On the other hand, the results show that, in the samples from the last three volcanic episodes in the island (Morro Vermelho Formation, Valado Formation and Vulcao do Paredao), the 230 Th and 238 U are not in

  8. Determination of Polychlorinated Diben-p-dioxins and Dibenzofurans in Flue Gas by High Resolution Gas Chromatography Coupled with High Resolution Spectrometry

    International Nuclear Information System (INIS)

    Chen, T.; Yan, J. H.; Li, X. D.; Cen, K. F.

    2007-01-01

    In 1988 the first municipal solid waste (MSW) incinerator plant was built in Shenzhen, China. Since then Beijing, Shanghai and other big cities have built a few MSW incineration plants. MSW incineration has gradually been used in some cities of China due to its advantages such as significant volume reduction (about 90%), mass reduction (about 70%), and toxicity reduction of the waste and energy recovery. However, MSW incineration is sometimes considered to the general public as the secondary pollution source, because of concerns about is toxic combustion byproducts (TCBs). Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are the most toxic compounds among the TCBs. In this paper, PCDD/Fs in flue gas produced from a MSW incinerator were isokinetically withdrawn and collected in a multi component sampling train. Then the PCDD/Fs samples were extracted, concentrated and cleaned up step by step. Finally, the determination of PCDD/Fs was carried out by high-resolution gas chromatography coupled with high-resolution mass spectrometry (HRGC/HRMS). The two PCDD/Fs emission levels were the similar, which was 0.115 and 0.096ng TEQ/Nm3 although different sampling time. The PCDD/Fs emission levels were lower than the PCDD/Fs emission regulation in China (1.0 ng TEQ / Nm3) and close to the developed countries' regulations, i.e., 0.1ng TEQ/Nm3. 2,3,4,7,8-Pentachlorodibenzofuran (2,3,4,7,8-PeCDF) was the dominant congener of the total TEQ

  9. Recent trends in application of multivariate curve resolution approaches for improving gas chromatography-mass spectrometry analysis of essential oils.

    Science.gov (United States)

    Jalali-Heravi, Mehdi; Parastar, Hadi

    2011-08-15

    Essential oils (EOs) are valuable natural products that are popular nowadays in the world due to their effects on the health conditions of human beings and their role in preventing and curing diseases. In addition, EOs have a broad range of applications in foods, perfumes, cosmetics and human nutrition. Among different techniques for analysis of EOs, gas chromatography-mass spectrometry (GC-MS) is the most important one in recent years. However, there are some fundamental problems in GC-MS analysis including baseline drift, spectral background, noise, low S/N (signal to noise) ratio, changes in the peak shapes and co-elution. Multivariate curve resolution (MCR) approaches cope with ongoing challenges and are able to handle these problems. This review focuses on the application of MCR techniques for improving GC-MS analysis of EOs published between January 2000 and December 2010. In the first part, the importance of EOs in human life and their relevance in analytical chemistry is discussed. In the second part, an insight into some basics needed to understand prospects and limitations of the MCR techniques are given. In the third part, the significance of the combination of the MCR approaches with GC-MS analysis of EOs is highlighted. Furthermore, the commonly used algorithms for preprocessing, chemical rank determination, local rank analysis and multivariate resolution in the field of EOs analysis are reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Improved Resolution of Hydrocarbon Structures and Constitutional Isomers in Complex Mixtures Using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Isaacman, Gabriel [Univ. of California, Berkeley, CA (United States); Wilson, Kevin R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Arthur W. H. [Univ. of California, Berkeley, CA (United States); Worton, David R. [Univ. of California, Berkeley, CA (United States). Aerosol Dynamics Inc., Berkeley, CA (United States); Kimmel, Joel R. [Aerodyne Research, Inc., Billerica, MA (United States); Univ. of Colorado, Boulder, CO (United States). Tofwerk AG, Thun (Switzerland); Nah, Theodora [Univ. of California, Berkeley, CA (United States); Hohaus, Thorsten [Aerodyne Research, Inc., Billerica, MA (United States); Gonin, Marc [Tofwerk AG, Thun (Switzerland); Kroll, Jesse H. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Worsnop, Douglas R. [Aerodyne Research, Inc., Billerica, MA (United States); Goldstein, Allen H. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-01-30

    Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography/mass spectrometry (GC/MS) techniques. In this study, we use vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally “unresolved complex mixture” by separating components by GC retention time, tR, and mass-to-charge ratio, m/z, which are used to determine carbon number, NC, and the number of rings and double bonds, NDBE. Constitutional isomers are resolved on the basis of tR, enabling the most complete quantitative analysis to date of structural isomers in an environmentally relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. Lastly, the classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

  11. Argentation chromatography coupled to ultrahigh-resolution mass spectrometry for the separation of a heavy crude oil.

    Science.gov (United States)

    Molnárné Guricza, Lilla; Schrader, Wolfgang

    2017-02-10

    Simplification of highly complex mixtures such as crude oil by using chromatographic methods makes it possible to get more detailed information about the composition of the analyte. Separation by argentation chromatography can be achieved based on the interaction of different strength between the silver ions (Ag + ) immobilized through a spacer on the silica gel surface and the π-bonds of the analytes. Heavy crude oils contain compounds with a high number of heteroatoms (N, O, S) and a high degree of unsaturation thus making them the perfect analyte for argentation chromatography. The direct coupling of argentation chromatography and ultrahigh-resolution mass spectrometry allows to continuously tracking the separation of the many different compounds by retention time and allows sensitive detection on a molecular level. Direct injection of a heavy crude oil into a ultrahigh-resolution mass spectrometer showed components with DBE of up to 25, whereas analytes with DBE of up to 35 could be detected only after separation with argentation chromatography. The reduced complexity achieved by the separation helps increasing the information depth. Copyright © 2016. Published by Elsevier B.V.

  12. Nanometric resolution in glow discharge optical emission spectroscopy and Rutherford backscattering spectrometry depth profiling of metal (Cr, Al) nitride multilayers

    International Nuclear Information System (INIS)

    Escobar Galindo, R.; Gago, R.; Fornies, E.; Munoz-Martin, A.; Climent Font, A.; Albella, J.M.

    2006-01-01

    In this work, we address the capability of glow discharge optical emission spectroscopy (GDOES) for fast and accurate depth profiling of multilayer nitride coatings down to the nanometer range. This is shown by resolving the particular case of CrN/AlN structures with individual thickness ranging from hundreds to few nanometers. In order to discriminate and identify artefacts in the GDOES depth profile due to the sputtering process, the layered structures were verified by Rutherford backscattering spectrometry (RBS) and scanning electron microscopy (SEM). The interfaces in the GDOES profiles for CrN/AlN structures are sharper than the ones measured for similar metal multilayers due to the lower sputtering rate of the nitrides. However, as a consequence of the crater shape, there is a linear degradation of the depth resolution with depth (approximately 40 nm/μm), saturating at a value of approximately half the thickness of the thinner layer. This limit is imposed by the simultaneous sputtering of consecutive layers. The ultimate GDOES depth resolution at the near surface region was estimated to be of 4-6 nm

  13. Phase I and phase II reductive metabolism simulation of nitro aromatic xenobiotics with electrochemistry coupled with high resolution mass spectrometry.

    Science.gov (United States)

    Bussy, Ugo; Chung-Davidson, Yu-Wen; Li, Ke; Li, Weiming

    2014-11-01

    Electrochemistry combined with (liquid chromatography) high resolution mass spectrometry was used to simulate the general reductive metabolism of three biologically important nitro aromatic molecules: 3-trifluoromethyl-4-nitrophenol (TFM), niclosamide, and nilutamide. TFM is a pesticide used in the Laurential Great Lakes while niclosamide and nilutamide are used in cancer therapy. At first, a flow-through electrochemical cell was directly connected to a high resolution mass spectrometer to evaluate the ability of electrochemistry to produce the main reduction metabolites of nitro aromatic, nitroso, hydroxylamine, and amine functional groups. Electrochemical experiments were then carried out at a constant potential of -2.5 V before analysis of the reduction products by LC-HRMS, which confirmed the presence of the nitroso, hydroxylamine, and amine species as well as dimers. Dimer identification illustrates the reactivity of the nitroso species with amine and hydroxylamine species. To investigate xenobiotic metabolism, the reactivity of nitroso species to biomolecules was also examined. Binding of the nitroso metabolite to glutathione was demonstrated by the observation of adducts by LC-ESI(+)-HRMS and the characteristics of their MSMS fragmentation. In conclusion, electrochemistry produces the main reductive metabolites of nitro aromatics and supports the observation of nitroso reactivity through dimer or glutathione adduct formation.

  14. Triacylglycerol profiling of microalgae strains for biofuel feedstock by liquid chromatography-high-resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    MacDougall, Karen M.; McNichol, Jesse; McGinn, Patrick J.; O' Leary, Stephen J.B.; Melanson, Jeremy E. [Institute for Marine Biosciences, National Research Council of Canada, Halifax, NS (Canada)

    2011-11-15

    Biofuels from photosynthetic microalgae are quickly gaining interest as a viable carbon-neutral energy source. Typically, characterization of algal feedstock involves breaking down triacylglycerols (TAG) and other intact lipids, followed by derivatization of the fatty acids to fatty acid methyl esters prior to analysis by gas chromatography (GC). However, knowledge of the intact lipid profile could offer significant advantages for discovery stage biofuel research such as the selection of an algal strain or the optimization of growth and extraction conditions. Herein, lipid extracts from microalgae were directly analyzed by ultra-high pressure liquid chromatography-mass spectrometry (UHPLC-MS) using a benchtop Orbitrap mass spectrometer. Phospholipids, glycolipids, and TAGs were analyzed in the same chromatographic run, using a combination of accurate mass and diagnostic fragment ions for identification. Using this approach, greater than 100 unique TAGs were identified over the six algal strains studied and TAG profiles were obtained to assess their potential for biofuel applications. Under the growth conditions employed, Botryococcus braunii and Scenedesmus obliquus yielded the most comprehensive TAG profile with a high abundance of TAGs containing oleic acid. (orig.)

  15. Improvement of the detector resolution in X-ray spectrometry by using the maximum entropy method

    International Nuclear Information System (INIS)

    Fernández, Jorge E.; Scot, Viviana; Giulio, Eugenio Di; Sabbatucci, Lorenzo

    2015-01-01

    In every X-ray spectroscopy measurement the influence of the detection system causes loss of information. Different mechanisms contribute to form the so-called detector response function (DRF): the detector efficiency, the escape of photons as a consequence of photoelectric or scattering interactions, the spectrum smearing due to the energy resolution, and, in solid states detectors (SSD), the charge collection artifacts. To recover the original spectrum, it is necessary to remove the detector influence by solving the so-called inverse problem. The maximum entropy unfolding technique solves this problem by imposing a set of constraints, taking advantage of the known a priori information and preserving the positive-defined character of the X-ray spectrum. This method has been included in the tool UMESTRAT (Unfolding Maximum Entropy STRATegy), which adopts a semi-automatic strategy to solve the unfolding problem based on a suitable combination of the codes MAXED and GRAVEL, developed at PTB. In the past UMESTRAT proved the capability to resolve characteristic peaks which were revealed as overlapped by a Si SSD, giving good qualitative results. In order to obtain quantitative results, UMESTRAT has been modified to include the additional constraint of the total number of photons of the spectrum, which can be easily determined by inverting the diagonal efficiency matrix. The features of the improved code are illustrated with some examples of unfolding from three commonly used SSD like Si, Ge, and CdTe. The quantitative unfolding can be considered as a software improvement of the detector resolution. - Highlights: • Radiation detection introduces distortions in X- and Gamma-ray spectrum measurements. • UMESTRAT is a graphical tool to unfold X- and Gamma-ray spectra. • UMESTRAT uses the maximum entropy method. • UMESTRAT’s new version produces unfolded spectra with quantitative meaning. • UMESTRAT is a software tool to improve the detector resolution.

  16. Bayesian approach to peak deconvolution and library search for high resolution gas chromatography - Mass spectrometry.

    Science.gov (United States)

    Barcaru, A; Mol, H G J; Tienstra, M; Vivó-Truyols, G

    2017-08-29

    A novel probabilistic Bayesian strategy is proposed to resolve highly coeluting peaks in high-resolution GC-MS (Orbitrap) data. Opposed to a deterministic approach, we propose to solve the problem probabilistically, using a complete pipeline. First, the retention time(s) for a (probabilistic) number of compounds for each mass channel are estimated. The statistical dependency between m/z channels was implied by including penalties in the model objective function. Second, Bayesian Information Criterion (BIC) is used as Occam's razor for the probabilistic assessment of the number of components. Third, a probabilistic set of resolved spectra, and their associated retention times are estimated. Finally, a probabilistic library search is proposed, computing the spectral match with a high resolution library. More specifically, a correlative measure was used that included the uncertainties in the least square fitting, as well as the probability for different proposals for the number of compounds in the mixture. The method was tested on simulated high resolution data, as well as on a set of pesticides injected in a GC-Orbitrap with high coelution. The proposed pipeline was able to detect accurately the retention times and the spectra of the peaks. For our case, with extremely high coelution situation, 5 out of the 7 existing compounds under the selected region of interest, were correctly assessed. Finally, the comparison with the classical methods of deconvolution (i.e., MCR and AMDIS) indicates a better performance of the proposed algorithm in terms of the number of correctly resolved compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Analysis of aluminium by atomic absorption spectrometry and analysis of thorium and uranium by alpha spectrometry in the black sand of Egypt

    International Nuclear Information System (INIS)

    Hannachi, Dhouha; Mathlouthi, Nadia

    2008-01-01

    Throughout the period of our project of end of study carried out in the Center ; main road Sciences and Nuclear Engineering's CNSTN in one is tallied took one Egypt black sand simple with an aim has of knowing the activities of the existing radio elements and especially Uranium and Thorium. In the same mining, we try to take another Egypt black sand simple an aim has knowing the mass of aluminum by using a techniques in Atomique Absorption Spectrophotometer. After the radio chemical and Spectrometry analysis of the black sand sample we found the results following: - Egypt black sand is contains isotopes of Uranium such as 234 U and 238 U; - The Egypt black sand is contains isotopes of Thorium such as 230 Th and 232 Th. - L' Aluminum is a major. (Author)

  18. Use of combined alpha-spectrometry and fission track analysis for the determination of 240Pu/239Pu ratios in human tissue

    International Nuclear Information System (INIS)

    Love, S.F.; Filby, R.H.; Glover, S.E.; Stuit, D.B.; Kathren, R.L.

    1998-01-01

    Plutonium and other actinides were determined in human autopsy tissues of occupationally exposed workers who were registrants of the United States Transuranium and Uranium Registries (USTUR). In this study, Pu was purified and isolated from Am, U and Th, after drying and wet-ashing of the tissues, and the addition of 238 Pu as a radiotracer. After electrodeposition onto vanadium planchets, the 239+240 Pu activity was determined by alpha-spectrometry. A fission track method was developed to determine 239 Pu in the presence of 238 Pu and 240 Pu, using Lexan TM polycarbonate detectors. Combining the two techniques allowed the determination of the 240 Pu/ 239 Pu activity and atom ratios. Data from selected USTUR cases are presented. (author)

  19. Determination of uranium and thorium in complex matrices by two solvent extraction separation techniques and photon electron rejecting alpha liquid spectrometry

    International Nuclear Information System (INIS)

    Ayranov, M.; Wacker, L.; Kraehenbuehl, U.

    2001-01-01

    The separation of uranium and thorium from complex matrixes such as marine sediments using solvent extraction and determination by means of photon-electron rejecting liquid alpha spectrometry (PERALS trademark) has successfully been performed. Two extraction schemes, using TOPO and HDEHP, respectively, were compared for the separation of uranium and thorium from the matrix components. The results show recoveries between 73 and 92% for 234 U, 238 U, 232 Th, 230 Th and 238 Th with an accuracy of the methods ±12%. Minimum detectable activities for counting time up to 500 000 seconds for 0.5 g sample material were between 0.34-1.15 Bq/kg for uranium and 0.31-1.66 Bq/kg for thorium. (orig.)

  20. Applications of Fourier Transform Ion Cyclotron Resonance (FT-ICR) and Orbitrap Based High Resolution Mass Spectrometry in Metabolomics and Lipidomics

    Science.gov (United States)

    Ghaste, Manoj; Mistrik, Robert; Shulaev, Vladimir

    2016-01-01

    Metabolomics, along with other “omics” approaches, is rapidly becoming one of the major approaches aimed at understanding the organization and dynamics of metabolic networks. Mass spectrometry is often a technique of choice for metabolomics studies due to its high sensitivity, reproducibility and wide dynamic range. High resolution mass spectrometry (HRMS) is a widely practiced technique in analytical and bioanalytical sciences. It offers exceptionally high resolution and the highest degree of structural confirmation. Many metabolomics studies have been conducted using HRMS over the past decade. In this review, we will explore the latest developments in Fourier transform mass spectrometry (FTMS) and Orbitrap based metabolomics technology, its advantages and drawbacks for using in metabolomics and lipidomics studies, and development of novel approaches for processing HRMS data. PMID:27231903

  1. Quantifying the benefits of ultrahigh energy resolution for Gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Drury, Owen B.; Terracol, Stephane F.; Friedrich, Stephan [Advanced Detector Group, Lawrence Livermore National Laboratory, L-270, Livermore CA 94550 (United States)

    2005-03-01

    Cryogenic Gamma-ray spectrometers operating at temperatures of {proportional_to}0.1 K provide an order of magnitude better energy resolution than conventional germanium detectors. Ultra-high energy resolution improves the accuracy of non-destructive analysis of nuclear materials, since a better separation of lines reduces statistical errors as well as systematic errors from background subtraction and efficiency correction. We are developing cryogenic Gamma-spectrometers based on bulk tin absorbers and superconducting molybdenum-copper sensors for nuclear forensics and non-proliferation applications. Here we quantify the improvements in accuracy for isotope analysis with cryogenic detectors in terms of detector performance for different cases of line separation, line intensity ratios and background levels. Precise measurements of isotope ratios are crucial in the context of nuclear attribution, since they provide signatures of composition, age, origin, intended purpose and processing history of illicit nuclear materials. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. Isotopomer analysis of lipid biosynthesis by high resolution mass spectrometry and NMR

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Andrew N., E-mail: anlane01@louisville.edu [JG Brown Cancer Center, 529 S. Jackson Street, Louisville, KY 40202 (United States); Center for Regulatory and Environmental Analytical Metabolomics (CREAM), University of Louisville, Louisville, KY (United States); Fan, Teresa W.-M. [JG Brown Cancer Center, 529 S. Jackson Street, Louisville, KY 40202 (United States); Center for Regulatory and Environmental Analytical Metabolomics (CREAM), University of Louisville, Louisville, KY (United States); Department of Chemistry, University of Louisville, Louisville, KY 40292 (United States); Xie, Zhengzhi; Moseley, Hunter N.B.; Higashi, Richard M. [Center for Regulatory and Environmental Analytical Metabolomics (CREAM), University of Louisville, Louisville, KY (United States); Department of Chemistry, University of Louisville, Louisville, KY 40292 (United States)

    2009-10-05

    We have coupled 2D-NMR and infusion FT-ICR-MS with computer-assisted assignment to profile {sup 13}C-isotopologues of glycerophospholipids (GPL) directly in crude cell extracts, resulting in very high information throughput of >3000 isobaric molecules in a few minutes. A mass accuracy of better than 1 ppm combined with a resolution of 100,000 at the measured m/z was required to distinguish isotopomers from other GPL structures. Isotopologue analysis of GPLs extracted from LCC2 breast cancer cells grown on [U-{sup 13}C]-glucose provided a rich trove of information about the biosynthesis and turnover of the GPLs. The isotopologue intensity ratios from the FT-ICR-MS were accurate to {approx}1% or better based on natural abundance background, and depended on the signal-to-nose ratio. The time course of incorporation of {sup 13}C from [U-{sup 13}C]-glucose into a particular phosphatidylcholine was analyzed in detail, to provide a quantitative measure of the sizes of glycerol, acetyl CoA and total GPL pools in growing LCC2 cells. Independent and complementary analysis of the positional {sup 13}C enrichment in the glycerol and fatty acyl chains obtained from high resolution 2D NMR was used to verify key aspects of the model. This technology enables simple and rapid sample preparation, has rapid analysis, and is generally applicable to unfractionated GPLs of almost any head group, and to mixtures of other classes of metabolites.

  3. Isotopomer analysis of lipid biosynthesis by high resolution mass spectrometry and NMR

    International Nuclear Information System (INIS)

    Lane, Andrew N.; Fan, Teresa W.-M.; Xie, Zhengzhi; Moseley, Hunter N.B.; Higashi, Richard M.

    2009-01-01

    We have coupled 2D-NMR and infusion FT-ICR-MS with computer-assisted assignment to profile 13 C-isotopologues of glycerophospholipids (GPL) directly in crude cell extracts, resulting in very high information throughput of >3000 isobaric molecules in a few minutes. A mass accuracy of better than 1 ppm combined with a resolution of 100,000 at the measured m/z was required to distinguish isotopomers from other GPL structures. Isotopologue analysis of GPLs extracted from LCC2 breast cancer cells grown on [U- 13 C]-glucose provided a rich trove of information about the biosynthesis and turnover of the GPLs. The isotopologue intensity ratios from the FT-ICR-MS were accurate to ∼1% or better based on natural abundance background, and depended on the signal-to-nose ratio. The time course of incorporation of 13 C from [U- 13 C]-glucose into a particular phosphatidylcholine was analyzed in detail, to provide a quantitative measure of the sizes of glycerol, acetyl CoA and total GPL pools in growing LCC2 cells. Independent and complementary analysis of the positional 13 C enrichment in the glycerol and fatty acyl chains obtained from high resolution 2D NMR was used to verify key aspects of the model. This technology enables simple and rapid sample preparation, has rapid analysis, and is generally applicable to unfractionated GPLs of almost any head group, and to mixtures of other classes of metabolites.

  4. Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Touber, M.E.; Engelen, M.C.; Georgakopoulus, C.; Rhijn, van J.A.; Nielen, M.W.F.

    2007-01-01

    A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC (TM)), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions

  5. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    NARCIS (Netherlands)

    Hennekam, Rick; Jilbert, Tom; Mason, Paul R D; de Lange, Gert J.; Reichart, Gert Jan

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (μm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  6. High-resolution line-scan analysis of resin-embedded sediments using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)

    NARCIS (Netherlands)

    Hennekam, R.; Jilbert, T.; de Lange, G.J.; Reichart, G.J.

    2015-01-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) line-scanning is a promising technique for producing high-resolution (µm-scale) geochemical records on resin-embedded sediments. However, this approach has not yet been thoroughly tested on sediment samples of known elemental

  7. Structural Characterization of a Thrombin-Aptamer Complex by High Resolution Native Top-Down Mass Spectrometry

    Science.gov (United States)

    Zhang, Jiang; Loo, Rachel R. Ogorzalek; Loo, Joseph A.

    2017-09-01

    Native mass spectrometry (MS) with electrospray ionization (ESI) has evolved as an invaluable tool for the characterization of intact native proteins and non-covalently bound protein complexes. Here we report the structural characterization by high resolution native top-down MS of human thrombin and its complex with the Bock thrombin binding aptamer (TBA), a 15-nucleotide DNA with high specificity and affinity for thrombin. Accurate mass measurements revealed that the predominant form of native human α-thrombin contains a glycosylation mass of 2205 Da, corresponding to a sialylated symmetric biantennary oligosaccharide structure without fucosylation. Native MS showed that thrombin and TBA predominantly form a 1:1 complex under near physiological conditions (pH 6.8, 200 mM NH4OAc), but the binding stoichiometry is influenced by the solution ionic strength. In 20 mM ammonium acetate solution, up to two TBAs were bound to thrombin, whereas increasing the solution ionic strength destabilized the thrombin-TBA complex and 1 M NH4OAc nearly completely dissociated the complex. This observation is consistent with the mediation of thrombin-aptamer binding through electrostatic interactions and it is further consistent with the human thrombin structure that contains two anion binding sites on the surface. Electron capture dissociation (ECD) top-down MS of the thrombin-TBA complex performed with a high resolution 15 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer showed the primary binding site to be at exosite I located near the N-terminal sequence of the heavy chain, consistent with crystallographic data. High resolution native top-down MS is complementary to traditional structural biology methods for structurally characterizing native proteins and protein-DNA complexes. [Figure not available: see fulltext.

  8. Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Buratto, Steven K. [UC Santa Barbara

    2013-09-03

    We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.

  9. Optimization of actinides trace precipitation on diamond/Si PIN sensor for alpha-spectrometry in aqueous solution

    International Nuclear Information System (INIS)

    Tran, Q.T.; Pomorski, M.; Sanoit, J. de; Mer-Calfati, C.; Scorsone, E.; Bergonzo, P.

    2014-01-01

    We report here on a new approach for the detection and identification of actinides (Pu, Am, Cm, etc). This approach is based on the use of a novel device consisting of a boron doped nanocrystalline diamond film deposited onto a silicon PIN diode alpha particle sensor. The actinides concentration is probed in situ in the measuring solution using a method based on electro-precipitation that can be carried out via the use of a doped diamond electrode. The device allows probing directly both alpha-particles activity and energy in liquid solutions. In this work, we address the optimization of the actinides electro-precipitation step onto the sensor. The approach is based on fine tuning the pH of the electrolyte, the nature of the supporting electrolytes (Na_2SO_4 or NaNO_3), the electrochemical cell geometry, the current density value, the precipitation duration as well as the sensor surface area. The deposition efficiency was significantly improved with values reaching for instance up to 81.5% in the case of electro-precipitation of 5.96 Bq "2"4"1Am on the sensor. The diamond/silicon sensor can be reused after measurement by performing a fast decontamination step at high yields 99%, where the "2"4"1Am electro-precipitated layer is quickly removed by applying an anodic current (+2 mA.cm"-"2 for 10 minutes) to the boron doped nanocrystalline diamond electrode in aqueous solution. This study demonstrated that alpha-particle spectroscopic measurements could be made feasible for the first time in aqueous solutions after an electrochemical deposition process, with theoretical detections thresholds as low as 0.24 Bq.L"-"1. We believe that this approach can be of very high interest for alpha-particle spectroscopy in liquids for actinides trace detection. (authors)

  10. High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Sigg, R.

    1990-01-01

    A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements

  11. Localization of an O-glycosylated site in the recombinant barley alpha-amylase 1 produced in yeast and correction of the amino acid sequence using matrix-assisted laser desorption/ionization mass spectrometry of peptide mixtures

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Søgaard, M; Svensson, B

    1994-01-01

    Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of peptide mixtures was used to characterize recombinant barley alpha-amylase 1, produced in yeast. Three peptide mixtures were generated by cleavage with CNBr, digestion with endoproteinase Lys-C and Asp-N, respectively...

  12. Feasibility of microwave interferometry and fourier-transform spectrometry for high-spectral-resolution sensing

    Energy Technology Data Exchange (ETDEWEB)

    Gerstl, S.; Cooke, B.; Jacobson, A.; Love, S.; Zardecki, A.

    1996-09-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The primary objective of this project was to perform the necessary research and development to determine the feasibility of new ideas that, if successful, could lead to the development of future new programs in high-spectral resolution remote sensing. In active remote sensing systems, the solar illumination of a scene is replaced by a man-made source, preferably a laser beam. However, when laser beams are propagated through a scattering medium, like air, random optical path fluctuations comparable to the optical wavelength are generated giving rise to the speckle effect, which is the most severe perturbation in active remote sensing systems. The limitations introduced by the speckle effect degrade or negate the data interpretation. We sought to introduce better physical models of beam scattering that allow a more realistic simulation environment to be developed that, when applied to experimental data sets, improve their interpretability and increase the information content. Improved beam propagation models require improved knowledge of the spatio-temporal distribution of the scattering and absorbing medium. In the free atmosphere the largest contributor is water vapor in the lower troposphere. We tested the feasibility of using microwave interferometry to measure water-vapor irregularities in the boundary layer. Knowledge of these distributions enable much improved atmospheric correction algorithms for satellite imagery of the earth`s surface to be developed. For hyperspectral active remote sensing systems it is necessary to perform very high-resolution spectral measurements of the reflected laser light. Such measurements are possible with optical interferometers.

  13. A study on the determination of Ca/P molar ratio in calcium-hydroxyapatite by alpha excited x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Iwata, Shiro.

    1979-01-01

    Nondestructive powdery calcium-hydroxyapatite (HAp) target was prepared by electrodeposition method. The powdery HAp was deposited on the copper electrode plate of cathode in the electrodeposition solution such as ethyl alcohol, methyl alcohol, etc. The experiments were carried out as functions of different electrodeposition solution, ethyl alcohol concentration, distance between anode and cathode, electrodeposition time and HAp amount added in bath, and distribution of HAp on the copper electrode plate obtained from each experiment was investigated by alpha excited X-ray fluorescence analysis. Ca/P molar ratio of thin HAp target prepared with this method was determined by alpha excited X-ray fluorescence spectrometry. The nondestructive HAp targets of thickness in the range of 5 mu g/cm 2 to 10 mg/cm 2 were easily prepared with comparatively simple apparatus. The HAp on the copper electrode plate was uniform thickness over 15 x 20 mm copper plate within 5%. The Ca/P molar ratio of HAp was 1.64 +- 0.05, which agreed well with stoichiometric value of 1.67 in HAp within standard deviation. (author)

  14. Quantitative and Selective Analysis of Feline Growth Related Proteins Using Parallel Reaction Monitoring High Resolution Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Mårten Sundberg

    Full Text Available Today immunoassays are widely used in veterinary medicine, but lack of species specific assays often necessitates the use of assays developed for human applications. Mass spectrometry (MS is an attractive alternative due to high specificity and versatility, allowing for species-independent analysis. Targeted MS-based quantification methods are valuable complements to large scale shotgun analysis. A method referred to as parallel reaction monitoring (PRM, implemented on Orbitrap MS, has lately been presented as an excellent alternative to more traditional selected reaction monitoring/multiple reaction monitoring (SRM/MRM methods. The insulin-like growth factor (IGF-system is not well described in the cat but there are indications of important differences between cats and humans. In feline medicine IGF-I is mainly analyzed for diagnosis of growth hormone disorders but also for research, while the other proteins in the IGF-system are not routinely analyzed within clinical practice. Here, a PRM method for quantification of IGF-I, IGF-II, IGF binding protein (BP -3 and IGFBP-5 in feline serum is presented. Selective quantification was supported by the use of a newly launched internal standard named QPrEST™. Homology searches demonstrated the possibility to use this standard of human origin for quantification of the targeted feline proteins. Excellent quantitative sensitivity at the attomol/μL (pM level and selectivity were obtained. As the presented approach is very generic we show that high resolution mass spectrometry in combination with PRM and QPrEST™ internal standards is a versatile tool for protein quantitation across multispecies.

  15. The expression profile of phosphatidylinositol in high spatial resolution imaging mass spectrometry as a potential biomarker for prostate cancer.

    Directory of Open Access Journals (Sweden)

    Takayuki Goto

    Full Text Available High-resolution matrix-assisted laser desorption/ionization imaging mass spectrometry (HR-MALDI-IMS is an emerging application for the comprehensive and detailed analysis of the spatial distribution of ionized molecules in situ on tissue slides. HR-MALDI-IMS in negative mode in a mass range of m/z 500-1000 was performed on optimal cutting temperature (OCT compound-embedded human prostate tissue samples obtained from patients with prostate cancer at the time of radical prostatectomy. HR-MALDI-IMS analysis of the 14 samples in the discovery set identified 26 molecules as highly expressed in the prostate. Tandem mass spectrometry (MS/MS showed that these molecules included 14 phosphatidylinositols (PIs, 3 phosphatidylethanolamines (PEs and 3 phosphatidic acids (PAs. Among the PIs, the expression of PI(18:0/18:1, PI(18:0/20:3 and PI(18:0/20:2 were significantly higher in cancer tissue than in benign epithelium. A biomarker algorithm for prostate cancer was formulated by analyzing the expression profiles of PIs in cancer tissue and benign epithelium of the discovery set using orthogonal partial least squares discriminant analysis (OPLS-DA. The sensitivity and specificity of this algorithm for prostate cancer diagnosis in the 24 validation set samples were 87.5 and 91.7%, respectively. In conclusion, HR-MALDI-IMS identified several PIs as being more highly expressed in prostate cancer than benign prostate epithelium. These differences in PI expression profiles may serve as a novel diagnostic tool for prostate cancer.

  16. Depth profiling of Pu, 241Am and 137Cs in soils from southern Belarus measured by ICP-MS and alpha and gamma spectrometry.

    Science.gov (United States)

    Boulyga, Sergei F; Zoriy, Myroslav; Ketterer, Michael E; Becker, J Sabine

    2003-08-01

    The depth distribution of plutonium, americium, and 137Cs originating from the 1986 accident at the Chernobyl Nuclear Power Plant (NPP) was investigated in several soil profiles in the vicinity from Belarus. The vertical migration of transuranic elements in soils typical of the 30 km relocation area around Chernobyl NPP was studied using inductively coupled plasma mass spectrometry (ICP-MS), alpha spectrometry, and gamma spectrometry. Transuranic concentrations in upper soil layers ranged from 6 x 10(-12) g g(-1) to 6 x 10(-10) g g(-1) for plutonium and from 1.8 x 10(-13) g g(-1) to 1.6 x 10(-11) g g(-1) for americium. These concentrations correspond to specific activities of (239+240)Pu of 24-2400 Bq kg(-1) and specific activity of 241Am of 23-2000 Bq kg(-1), respectively. Transuranics in turf-podzol soil migrate slowly to the deeper soil layers, thus, 80-95%, of radionuclide inventories were present in the 0-3 cm intervals of turf-podzol soils collected in 1994. In peat-marsh soil migration processes occur more rapidly than in turf-podzol and the maximum concentrations are found beneath the soil surface (down to 3-6 cm). The depth distributions of Pu and Am are essentially identical for a given soil profile. (239+240)Pu/137Cs and 241Am/137Cs activity ratios vary by up to a factor of 5 at some sites while smaller variations in these ratios were observed at a site close to Chernobyl, suggesting that 137Cs is dominantly particle associated close to Chernobyl but volatile species of 137Cs are of relatively greater importance at the distant sites.

  17. Contribution to the study of the {alpha} spectrometry by the impulse ionization chamber. Application to the study of the beam fine structure of some heavy nuclei; Contribution a l'etude de la spectrometrie {alpha} par la chambre d'ionisation a impulsion. Application a l'etude de la structure fine du rayonnement de quelques noyaux lourds

    Energy Technology Data Exchange (ETDEWEB)

    Valladas, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1954-05-15

    In the first part, it studies an impulse spectrometer of which the resolution and stability have been pushed to their maximum possibilities. It uses an ionization chamber because of its simple and steady functioning. The general characteristics and building of the ionization chamber are described. The electronic devices are described as well as the recording system. The theoretical study of the amplifier has allowed to reduce the amplitude dispersion from electronic devices as background noise. The resolution in energy of an {alpha} spectrometer using an impulse ionization chamber is studied and results are discussed. The spectral lines display of the fine structure under the effect of conversion electrons emitted by coincidence in the ionization chamber is studied. Finally, the detection possibilities of very low intensity spectral lines of fine structure of detection are considered. In the second part, the {alpha} emission of fine structure of {sup 230}Th, {sup 234}U and {sup 238}U nuclei is studied. (M.P.)

  18. Structural Characterization of Laboratory Made Tholins by IRMPD Action Spectroscopy and Ultrahigh Resolution Mass Spectrometry

    Science.gov (United States)

    Thissen, R.; Somogyi, A.; Vuitton, V.; Bégué, D.; Lemaire, J.; Steinmetz, V.

    2011-10-01

    The complex organic material that is found on the surface and within the haze layer of Titan is attributed to chemistry occurring in its thick N2/CH4 atmosphere. Although several groups are producing in various laboratory setting the socalled tholins which have been investigated by using analytical methods including UV/Vis, fluorescence, IR, and MS1-5, these very complex organic mixtures still hold many unanswered questions, especially related to the potentiality for their prebiotic chemistry. In addition to tholins characterization and analysis, we recently investigated quantitatively the hydrolysis kinetics of tholins in pure and NH3 containing water at different temperatures.7-8 Our groups at UJF (Grenoble) and at U of Arizona (Tucson) have been collaborating on mass spectral analyses of tholins samples for several years.9 Here, we report our most recent results on the structural characterization of tholins by infrared multiphoton dissociation (IRMPD) action spectroscopy10 and ultrahigh resolution MS. IRMPD action spectroscopy is a recently developed technique that uses IR photons of variable wavelengths to activate ions trapped inside an ion trap. When photons are absorbed at a given wavelength, the selected ion fragments and this fragmentation is monitored as a function of wavelength, analog to an absorption spectrum (impossible to record otherwise because of the much reduced density). This technique can, therefore, be used to determine IR spectra of ions in the gas phase, and provides with very acute structural information. IRMPD action spectroscopy is often used to distinguish between structural isomers of isobaric ions. The drawback is that it requests for high power lasers. Only two Free Electron Lasers (FEL) are available in the world and allow to record spectra with reasonable resolution (20-25 cm-1). IRMPD action spectra of selected ions from tholins will be presented and discussed together with observed fragmentation processes that reveal structural

  19. Quantitative analysis of multiple high-resolution mass spectrometry images using chemometric methods: quantitation of chlordecone in mouse liver.

    Science.gov (United States)

    Mohammadi, Saeedeh; Parastar, Hadi

    2018-05-15

    In this work, a chemometrics-based strategy is developed for quantitative mass spectrometry imaging (MSI). In this regard, quantification of chlordecone as a carcinogenic organochlorinated pesticide (C10Cll0O) in mouse liver using the matrix-assisted laser desorption ionization MSI (MALDI-MSI) method is used as a case study. The MSI datasets corresponded to 1, 5 and 10 days of mouse exposure to the standard chlordecone in the quantity range of 0 to 450 μg g-1. The binning approach in the m/z direction is used to group high resolution m/z values and to reduce the big data size. To consider the effect of bin size on the quality of results, three different bin sizes of 0.25, 0.5 and 1.0 were chosen. Afterwards, three-way MSI data arrays (two spatial and one m/z dimensions) for seven standards and four unknown samples were column-wise augmented with m/z values as the common mode. Then, these datasets were analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) using proper constraints. The resolved mass spectra were used for identification of chlordecone in the presence of a complex background and interference. Additionally, the augmented spatial profiles were post-processed and 2D images for each component were obtained in calibration and unknown samples. The sum of these profiles was utilized to set the calibration curve and to obtain the analytical figures of merit (AFOMs). Inspection of the results showed that the lower bin size (i.e., 0.25) provides more accurate results. Finally, the obtained results by MCR for three datasets were compared with those of gas chromatography-mass spectrometry (GC-MS) and MALDI-MSI. The results showed that the MCR-assisted method gives a higher amount of chlordecone than MALDI-MSI and a lower amount than GC-MS. It is concluded that a combination of chemometric methods with MSI can be considered as an alternative way for MSI quantification.

  20. High-Resolution Liquid Chromatography Tandem Mass Spectrometry Enables Large Scale Molecular Characterization of Dissolved Organic Matter

    Directory of Open Access Journals (Sweden)

    Daniel Petras

    2017-12-01

    Full Text Available Dissolved organic matter (DOM is arguably one of the most complex exometabolomes on earth, and is comprised of thousands of compounds, that together contribute more than 600 × 1015 g carbon. This reservoir is primarily the product of interactions between the upper ocean's microbial food web, yet abiotic processes that occur over millennia have also modified many of its molecules. The compounds within this reservoir play important roles in determining the rate and extent of element exchange between inorganic reservoirs and the marine biosphere, while also mediating microbe-microbe interactions. As such, there has been a widespread effort to characterize DOM using high-resolution analytical methods including nuclear magnetic resonance spectroscopy (NMR and mass spectrometry (MS. To date, molecular information in DOM has been primarily obtained through calculated molecular formulas from exact mass. This approach has the advantage of being non-targeted, accessing the inherent complexity of DOM. Molecular structures are however still elusive and the most commonly used instruments are costly. More recently, tandem mass spectrometry has been employed to more precisely identify DOM components through comparison to library mass spectra. Here we describe a data acquisition and analysis workflow that expands the repertoire of high-resolution analytical approaches available to access the complexity of DOM molecules that are amenable to electrospray ionization (ESI MS. We couple liquid chromatographic separation with tandem MS (LC-MS/MS and a data analysis pipeline, that integrates peak extraction from extracted ion chromatograms (XIC, molecular formula calculation and molecular networking. This provides more precise structural characterization. Although only around 1% of detectable DOM compounds can be annotated through publicly available spectral libraries, community-wide participation in populating and annotating DOM datasets could rapidly increase the

  1. Screening new psychoactive substances in urban wastewater using high resolution mass spectrometry.

    Science.gov (United States)

    González-Mariño, Iria; Gracia-Lor, Emma; Bagnati, Renzo; Martins, Claudia P B; Zuccato, Ettore; Castiglioni, Sara

    2016-06-01

    Analysis of drug residues in urban wastewater could complement epidemiological studies in detecting the use of new psychoactive substances (NPS), a continuously changing group of drugs hard to monitor by classical methods. We initially selected 52 NPS potentially used in Italy based on seizure data and consumption alerts provided by the Antidrug Police Department and the National Early Warning System. Using a linear ion trap-Orbitrap high resolution mass spectrometer, we designed a suspect screening and a target method approach and compared them for the analysis of 24 h wastewater samples collected at the treatment plant influents of four Italian cities. This highlighted the main limitations of these two approaches, so we could propose requirements for future research. A library of MS/MS spectra of 16 synthetic cathinones and 19 synthetic cannabinoids, for which analytical standards were acquired, was built at different collision energies and is available on request. The stability of synthetic cannabinoids was studied in analytical standards and wastewater, identifying the best analytical conditions for future studies. To the best of our knowledge, these are the first stability data on NPS. Few suspects were identified in Italian wastewater samples, in accordance with recent epidemiological data reporting a very low prevalence of use of NPS in Italy. This study outlines an analytical approach for NPS identification and measurement in urban wastewater and for estimating their use in the population.

  2. Identification of amines in wintertime ambient particulate material using high resolution aerosol mass spectrometry

    Science.gov (United States)

    Bottenus, Courtney L. H.; Massoli, Paola; Sueper, Donna; Canagaratna, Manjula R.; VanderSchelden, Graham; Jobson, B. Thomas; VanReken, Timothy M.

    2018-05-01

    Significant amounts of amines were detected in fine particulate matter (PM) during ambient wintertime conditions in Yakima, WA, using a high resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS). Positive matrix factorization (PMF) of the organic aerosol (OA) signal resulted in a six-factor solution that included two previously unreported amine OA factors. The contributions of the amine factors were strongly episodic, but the concentration of the combined amine factors was as high as 10-15 μg m-3 (2-min average) during those episodes. In one occasion, the Amine-II component was 45% of total OA signal. The Amine-I factor was dominated by spectral peaks at m/z 86 (C5H12N+) and m/z 100 (C6H14N+), while the Amine-II factor was dominated by spectral peaks at m/z 58 (C3H8N+ and C2H6N2+) and m/z 72 (C4H10N+ and C3H8N2+). The ions dominating each amine factor showed distinct time traces, suggesting different sources or formation processes. Investigation into the chemistry of the amine factors suggests a correlation with inorganic anions for Amine-I, but no evidence that the Amine-II was being neutralized by the same inorganic ions. We also excluded the presence of organonitrates (ON) in the OA. The presence of C2H4O2+ at m/z 60 (a levoglucosan fragment) in the Amine-I spectrum suggests some influence of biomass burning emissions (more specifically residential wood combustion) in this PMF factor, but wind direction suggested that the most likely sources of these amines were agricultural activities and feedlots to the S-SW of the site.

  3. High-resolution mass spectrometry driven discovery of peptidic danger signals in insect immunity.

    Directory of Open Access Journals (Sweden)

    Arton Berisha

    Full Text Available The 'danger model' is an alternative concept for immune response postulating that the immune system reacts to entities that do damage (danger associated molecular patterns, DAMP and not only to entities that are foreign (pathogen-associated molecular patterns, PAMP as proposed by classical immunology concepts. In this study we used Galleria mellonella to validate the danger model in insects. Hemolymph of G. mellonella was digested with thermolysin (as a representative for virulence-associated metalloproteinases produced by humanpathogens followed by chromatographic fractionation. Immune-stimulatory activity was tested by measuring lysozyme activity with the lytic zone assays against Micrococcus luteus cell wall components. Peptides were analyzed by nano-scale liquid chromatography coupled to high-resolution Fourier transform mass spectrometers. Addressing the lack of a genome sequence we complemented the rudimentary NCBI protein database with a recently established transcriptome and de novo sequencing methods for peptide identification. This approach led to identification of 127 peptides, 9 of which were identified in bioactive fractions. Detailed MS/MS experiments in comparison with synthetic analogues confirmed the amino acid sequence of all 9 peptides. To test the potential of these putative danger signals to induce immune responses we injected the synthetic analogues into G. mellonella and monitored the anti-bacterial activity against living Micrococcus luteus. Six out of 9 peptides identified in the bioactive fractions exhibited immune-stimulatory activity when injected. Hence, we provide evidence that small peptides resulting from thermolysin-mediated digestion of hemolymph proteins function as endogenous danger signals which can set the immune system into alarm. Consequently, our study indicates that the danger model also plays a role in insect immunity.

  4. In-situ high resolution particle sampling by large time sequence inertial spectrometry

    International Nuclear Information System (INIS)

    Prodi, V.; Belosi, F.

    1990-09-01

    In situ sampling is always preferred, when possible, because of the artifacts that can arise when the aerosol has to flow through long sampling lines. On the other hand, the amount of possible losses can be calculated with some confidence only when the size distribution can be measured with a sufficient precision and the losses are not too large. This makes it desirable to sample directly in the vicinity of the aerosol source or containment. High temperature sampling devices with a detailed aerodynamic separation are extremely useful to this purpose. Several measurements are possible with the inertial spectrometer (INSPEC), but not with cascade impactors or cyclones. INSPEC - INertial SPECtrometer - has been conceived to measure the size distribution of aerosols by separating the particles while airborne according to their size and collecting them on a filter. It consists of a channel of rectangular cross-section with a 90 degree bend. Clean air is drawn through the channel, with a thin aerosol sheath injected close to the inner wall. Due to the bend, the particles are separated according to their size, leaving the original streamline by a distance which is a function of particle inertia and resistance, i.e. of aerodynamic diameter. The filter collects all the particles of the same aerodynamic size at the same distance from the inlet, in a continuous distribution. INSPEC particle separation at high temperature (up to 800 C) has been tested with Zirconia particles as calibration aerosols. The feasibility study has been concerned with resolution and time sequence sampling capabilities under high temperature (700 C)

  5. Characterization of the occupational exposure and air transported particles using the techniques of PIXE 252Cf PMDS and alpha spectrometry

    International Nuclear Information System (INIS)

    Carneiro, Luana Gomes

    2008-01-01

    The risk for human health due to exposure to aerosols depends on the intake pattern, the mass concentration and the speciation of the elements present in airborne particles. In this work PDMS (Plasma Desorption Mass Spectrometry) was used as complementary technique to the PIXE (Particle Induced X ray Emission) technique to characterize aerosols samples collected in the environment. The PIXE technique allows the identification of the elements present in the sample and to determine their mass concentrations. The mass spectrometry (PDMS) was used to identify the speciation of these elements present in the samples. The aerosol samples were collected using a six stage cascade impactor in three sites. The Mass Median Aerodynamic Diameter (MMAD) measured indicated that the airborne particulate were in the fine fraction of the aerosols. The theoretical uranium concentration in urine samples using ICRP lung model parameters suggest that the elemental mass concentration in respirable fraction of aerosol and the chemical speciation are important factors to determine the uranium concentration in urine and that the determination of specific solubility parameters for each compound is the most important factor to calculate the uranium concentration in urine. PIXE allows to identify and quantify the elements heavier than Na (Z=11) while PDMS allows to identify the organic and inorganic compounds present in the samples. As these techniques are used as complementary techniques they provide important information about the aerosols characterization. (author)

  6. Qualitative and Quantitative Analysis of Andrographis paniculata by Rapid Resolution Liquid Chromatography/Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jian-Fei Qin

    2013-09-01

    Full Text Available A rapid resolution liquid chromatography/time-of-flight tandem mass spectrometry (RRLC-TOF/MS method was developed for qualitative and quantitative analysis of the major chemical constituents in Andrographis paniculata. Fifteen compounds, including flavonoids and diterpenoid lactones, were unambiguously or tentatively identified in 10 min by comparing their retention times and accurate masses with standards or literature data. The characteristic fragmentation patterns of flavonoids and diterpenoid lactones were summarized, and the structures of the unknown compounds were predicted. Andrographolide, dehydroandrographolide and neoandrographolide were further quantified as marker substances. It was found that the calibration curves for all analytes showed good linearity (R2 > 0.9995 within the test ranges. The overall limits of detection (LODs and limits of quantification (LOQs were 0.02 μg/mL to 0.06 μg/mL and 0.06 μg/mL to 0.2 μg/mL, respectively. The relative standard deviations (RSDs for intra- and inter-day precisions were below 3.3% and 4.2%, respectively. The mean recovery rates ranged from 96.7% to 104.5% with the relative standard deviations (RSDs less than 2.72%. It is concluded that RRLC-TOF/MS is powerful and practical in qualitative and quantitative analysis of complex plant samples due to time savings, sensitivity, precision, accuracy and lowering solvent consumption.

  7. Screening for exogenous androgen anabolic steroids in human hair by liquid chromatography/orbitrap-high resolution mass spectrometry.

    Science.gov (United States)

    Strano-Rossi, Sabina; Castrignanò, Erika; Anzillotti, Luca; Odoardi, Sara; De-Giorgio, Fabio; Bermejo, Ana; Pascali, Vincenzo L

    2013-09-02

    A method for the screening of various anabolic steroids and their esters in human hair, based on liquid-chromatography-high resolution mass spectrometry using an Exactive benchtop Orbitrap mass spectrometer, has been set up and validated. This method involved methanolic incubation of 30 mg of hair and analysis of the relevant extract in HPLC using a C18 column. The mass detector, with nominal resolving power of 100,000, operated in full scan mode in APCI under positive ionization mode. Analytes were identified by exact mass, correspondence of isotopic cluster and retention times. The limits of detection obtained varied from 10 to 50 pg mg(-1), and limits of quantitation were 0.5 ng mg(-1) for all compounds. The method was linear for all analytes in the ranges from the LOQ to 6 ng mg(-1), giving correlation coefficients >0.99 for all analytes. Also accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Specificity was assessed by analysing ten blank samples and fifteen samples from polidrug abusers. This method was applied to a real-life case, resulting in the identification of testosterone undecanoate in the hair of a suspect. The analyte identity was confirmed by the analysis of its in-source fragmentation and comparison to a certified standard. Thanks to the scan acquisition, this method also enables retrospective re-analysis of the acquired datafile in case a further analyte needs to be screened. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. High-throughput untargeted screening of veterinary drug residues and metabolites in tilapia using high resolution orbitrap mass spectrometry.

    Science.gov (United States)

    Jia, Wei; Chu, Xiaogang; Chang, James; Wang, Perry G; Chen, Ying; Zhang, Feng

    2017-03-08

    An analytical method was developed and validated for simultaneous analysis of one hundred and thirty-seven veterinary drug residues and metabolites from sixteen different classes in tilapia utilizing an improved fully non-targeted way of data acquisition with fragmentation. The automated on-line extraction procedure was achieved in a simple disposable pipet extraction. Ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC Q-Orbitrap) was used for the separation and detection of all the analytes. The methodology was validated by taking into consideration the guidelines specified in European SANCO/12571/2013 Guideline 2013 and Commission Decision 2002/657/EC. The extraction recoveries ranged from 81% to 111%. The limits of decision ranged from 0.01 to 2.73 μg kg -1 and the detection capabilities ranged from 0.01 to 4.73 μg kg -1 . The one hundred and thirty-seven compounds behave dynamic 0.1-500 μg kg -1 , with correlation coefficient >0.99. The fully non-targeted data acquisition way improves both sensitivity and selectivity for the fragments, which is beneficial for screening performance and identification capability. This validated method has been successfully applied on screening of veterinary drug residues and metabolites in muscle of tilapia, an important and intensively produced fish in aquaculture. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Liquid chromatography-high resolution mass spectrometry for the analysis of phytochemicals in vegetal-derived food and beverages.

    Science.gov (United States)

    La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Montone, Carmela Maria; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2017-10-01

    The recent years witnessed a change in the perception of nutrition. Diet does not only provide nutrients to meet the metabolic requirements of the body, but it also constitutes an active way for the consumption of compounds beneficial for human health. Fruit and vegetables are an excellent source of such compounds, thus the growing interest in characterizing phytochemical sources, structures and activities. Given the interest for phytochemicals in food, the development of advanced and suitable analytical techniques for their identification is fundamental for the advancement of food research. In this review, the state of the art of phytochemical research in food plants is described, starting from sample preparation, throughout extract clean-up and compound separation techniques, to the final analysis, considering both qualitative and quantitative investigations. In this regard, from an analytical point of view, fruit and vegetable extracts are complex matrices, which greatly benefit from the use of modern hyphenated techniques, in particular from the combination of high performance liquid chromatography separation and high resolution mass spectrometry, powerful tools which are being increasingly used in the recent years. Therefore, selected applications to real samples are presented and discussed, in particular for the analysis of phenols, polyphenols and phenolic acids. Finally, some hot points are discussed, such as waste characterization for high value-compounds recovery and the untargeted metabolomics approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Metabolic profile modifications in milk after enrofloxacin administration studied by liquid chromatography coupled with high resolution mass spectrometry.

    Science.gov (United States)

    Junza, A; Saurina, J; Barrón, D; Minguillón, C

    2016-08-19

    High resolution accurate mass spectrometry (HRMS) operating in full scan MS mode was used in the search and identification of metabolites in raw milk from cows medicated with enrofloxacin. Data consisting of m/z features were taken throughout the entire chromatogram of milk samples from medicated animals and were compared with blank samples. Twenty six different compounds were identified. Some of them were attributed to structures related to enrofloxacin while others were dipeptides or tripeptides. Additionally, enrofloxacin was administered in a controlled treatment for three days. Milk was collected daily from the first day of treatment and until four days after in the search for the identified compounds. The obtained data were chemometrically treated by Principal Component Analysis. Samples were classified by this method into three different groups corresponding to days 1-2, day 3 and days 4-7 considering the different concentration profile evolution of metabolites during the days studied. Tentative metabolic pathways were designed to rationalize the presence of the newly identified compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Current applications of high-resolution mass spectrometry for the analysis of new psychoactive substances: a critical review.

    Science.gov (United States)

    Pasin, Daniel; Cawley, Adam; Bidny, Sergei; Fu, Shanlin

    2017-10-01

    The proliferation of new psychoactive substances (NPS) in recent years has resulted in the development of numerous analytical methods for the detection and identification of known and unknown NPS derivatives. High-resolution mass spectrometry (HRMS) has been identified as the method of choice for broad screening of NPS in a wide range of analytical contexts because of its ability to measure accurate masses using data-independent acquisition (DIA) techniques. Additionally, it has shown promise for non-targeted screening strategies that have been developed in order to detect and identify novel analogues without the need for certified reference materials (CRMs) or comprehensive mass spectral libraries. This paper reviews the applications of HRMS for the analysis of NPS in forensic drug chemistry and analytical toxicology. It provides an overview of the sample preparation procedures in addition to data acquisition, instrumental analysis, and data processing techniques. Furthermore, it gives an overview of the current state of non-targeted screening strategies with discussion on future directions and perspectives of this technique. Graphical Abstract Missing the bullseye - a graphical respresentation of non-targeted screening. Image courtesy of Christian Alonzo.

  12. Determination of sulfur in coal and ash slurry by high-resolution continuum source electrothermal molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nakadi, Flávio V.; Rosa, Lilian R.; Veiga, Márcia A.M.S. da, E-mail: mamsveiga@ffclrp.usp.br

    2013-10-01

    We propose a procedure for the determination of sulfur in coal slurries by high resolution continuum source electrothermal molecular absorption spectrometry. The slurry, whose concentration is 1 mg mL{sup −1}, was prepared by mixing 50 mg of the sample with 5% v/v nitric acid and 0.04% m/v Triton X-100 and was homogenized manually. It sustained good stability. The determination was performed via CS molecular absorption at 257.592 nm, and the optimized vaporization temperature was 2500 °C. The accuracy of the method was ensured by analysis of certified reference materials SRM 1632b (trace elements in coal) and SRM 1633b (coal fly ash) from the National Institute of Standards and Technology, using external calibration with aqueous standards prepared in the same medium and used as slurry. We achieved good agreement with the certified reference materials within 95% confidence interval, LOD of 0.01% w/w, and RSD of 6%, which confirms the potential of the proposed method. - Highlights: • HR-CS ET MAS as a technique to determine sulfur in coal and ash • Utilization of (coal and coal fly ash) slurry as a sample preparation • Simple and fast method, which uses external calibration with aqueous standards without chemical modifier.

  13. Analysis of volatile thiols in alcoholic beverages by simultaneous derivatization/extraction and liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Vichi, Stefania; Cortés-Francisco, Nuria; Caixach, Josep

    2015-05-15

    A simultaneous derivatization/extraction method followed by liquid chromatography-electrospray-high resolution mass spectrometry for the determination of volatile thiols in hydroalcoholic matrixes was optimized and used to identify and quantify volatile thiols in wine and beer samples. The method was evaluated in terms of sensitivity, precision, accuracy and selectivity. The experimental LOQs of eleven thiols tested ranged between 0.01 ng/L and 10 ng/L. Intra-day relative standard deviation (RSD) was in general lower than 10% and inter-day RSD ranged between 10% and 30%. Recovery in the model and real matrixes ranged from 45% to 129%. The method was then applied for the analysis of four white wines and six beers. Five out of the eleven reference thiols were identified and quantified in the samples analyzed. The non-target approach, carried out by monitoring the diagnostic ion at m/z 275.9922 [C13H10ONSe](+) in the fragmentation spectrum, allowed detecting, in the same samples, fourteen non-target thiols. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Ultra-high performance liquid chromatography tandem high-resolution mass spectrometry study of tricyclazole photodegradation products in water.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Bolfi, Bianca; Marengo, Emilio

    2015-06-01

    This paper reports the study of the photodegradation reactions that tricyclazole can naturally undergo, under the action of sunlight, in aqueous solutions of standard tricyclazole and of the commercial BEAM(TM) formulation. The analyses are carried out by ultra-high performance liquid chromatography technique coupled with high-resolution tandem mass spectrometry. Analysis of both tricyclazole and BEAM(TM) water solutions undergone to hydrolysis does not evidence new chromatographic peaks with respect to the not treated solutions. On the contrary, analysis of the same samples subjected to sunlight irradiation shows a decreased intensity of tricyclazole signal and the presence of new chromatographic peaks. Two photodegradation products of tricyclazole have been identified, one of which has been also quantified, being the commercial standard available. The pattern is similar for the solutions of the standard fungicide and of the BEAM(TM) formulation. The results obtained from eco-toxicological tests show that toxicity of tricyclazole standard solutions is greater than that of the irradiated ones, whereas toxicity levels of all the BEAM(TM) solutions investigated (non-irradiated, irradiated, and hydrolyzed) are comparable and lower than those shown by tricyclazole standard solutions. Experiments performed in paddy water solution show that there is no difference in the degradation products formed.

  15. Molecular-level evidence provided by ultrahigh resolution mass spectrometry for oil-derived doc in groundwater at Bemidji, Minnesota

    Science.gov (United States)

    Islam, Ananna; Ahmed, Arif; Hur, Manhoi; Thorn, Kevin A.; Kim, Sunghwan

    2016-01-01

    Dissolved organic matter samples extracted from ground water at the USGS Bemidji oil spill site in Minnesota were investigated by ultrahigh resolution mass spectrometry. Principle component analysis (PCA) of the elemental composition assignments of the samples showed that the score plots for the contaminated sites were well separated from those for the uncontaminated sites. Additionally, spectra obtained from the same sampling site 7 and 19 years after the spill were grouped together in the score plot, strongly suggesting a steady state of contamination within the 12 year interval. The double bond equivalence (DBE) of Ox class compounds was broader for the samples from the contaminated sites, because of the complex nature of oil and the consequent formation of compounds with saturated and/or aromatic structures from the oxygenated products of oil. In addition, Ox class compounds with a relatively smaller number of x (x < 8; x = number of oxygen) and OxS1 class compounds were more abundant in the samples from the contaminated sites, because of the lower oxygen and higher sulfur contents of the oil compared to humic substances. The molecular-level signatures presented here can be a fundamental basis for in-depth analysis of oil contamination.

  16. Detailed Source-Specific Molecular Composition of Ambient Aerosol Organic Matter Using Ultrahigh Resolution Mass Spectrometry and 1H NMR

    Directory of Open Access Journals (Sweden)

    Amanda S. Willoughby

    2016-06-01

    Full Text Available Organic aerosols (OA are universally regarded as an important component of the atmosphere that have far-ranging impacts on climate forcing and human health. Many of these impacts are related to OA molecular characteristics. Despite the acknowledged importance, current uncertainties related to the source apportionment of molecular properties and environmental impacts make it difficult to confidently predict the net impacts of OA. Here we evaluate the specific molecular compounds as well as bulk structural properties of total suspended particulates in ambient OA collected from key emission sources (marine, biomass burning, and urban using ultrahigh resolution mass spectrometry (UHR-MS and proton nuclear magnetic resonance spectroscopy (1H NMR. UHR-MS and 1H NMR show that OA within each source is structurally diverse, and the molecular characteristics are described in detail. Principal component analysis (PCA revealed that (1 aromatic nitrogen species are distinguishing components for these biomass burning aerosols; (2 these urban aerosols are distinguished by having formulas with high O/C ratios and lesser aromatic and condensed aromatic formulas; and (3 these marine aerosols are distinguished by lipid-like compounds of likely marine biological origin. This study provides a unique qualitative approach for enhancing the chemical characterization of OA necessary for molecular source apportionment.

  17. Novel approaches in analysis of Fusarium mycotoxins in cereals employing ultra performance liquid chromatography coupled with high resolution mass spectrometry

    International Nuclear Information System (INIS)

    Zachariasova, M.; Lacina, O.; Malachova, A.; Kostelanska, M.; Poustka, J.; Godula, M.; Hajslova, J.

    2010-01-01

    Rapid, simple and cost-effective analytical methods with performance characteristics matching regulatory requirements are needed for effective control of occurrence of Fusarium toxins in cereals and cereal-based products to which they might be transferred during processing. Within this study, two alternative approaches enabling retrospective data analysis and identification of unknown signals in sample extracts have been implemented and validated for determination of 11 major Fusarium toxins. In both cases, ultra-high performance liquid chromatography (U-HPLC) coupled with high resolution mass spectrometry (HR MS) was employed. 13 C isotopically labeled surrogates as well as matrix-matched standards were employed for quantification. As far as time of flight mass analyzer (TOF-MS) was a detection tool, the use of modified QuEChERS (quick easy cheap effective rugged and safe) sample preparation procedure, widely employed in multi-pesticides residue analysis, was shown as an optimal approach to obtain low detection limits. The second challenging alternative, enabling direct analysis of crude extract, was the use of mass analyzer based on Orbitrap technology. In addition to demonstration of full compliance of the new methods with Commission Regulation (EC) No. 401/2006, also their potential to be used for confirmatory purposes according to Commission Decision 2002/657/EC has been critically assessed.

  18. Determination of total sulfur in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry.

    Science.gov (United States)

    Virgilio, Alex; Raposo, Jorge L; Cardoso, Arnaldo A; Nóbrega, Joaquim A; Gomes Neto, José A

    2011-03-23

    The usefulness of molecular absorption was investigated for the determination of total sulfur (S) in agricultural samples by high-resolution continuum source flame molecular absorption spectrometry. The lines for CS at 257.595, 257.958, and 258.056 nm and for SH at 323.658, 324.064, and 327.990 nm were evaluated. Figures of merit, such as linear dynamic range, sensitivity, linear correlation, characteristic concentration, limit of detection, and precision, were established. For selected CS lines, wavelength-integrated absorbance equivalent to 3 pixels, analytical curves in the 100-2500 mg L(-1) (257.595 nm), 250-2000 mg L(-1) (257.958 nm), and 250-5000 mg L(-1) (258.056 nm) ranges with a linear correlation coefficient better than 0.9980 were obtained. Results were in agreement at a 95% confidence level (paired t test) with those obtained by gravimetry. Recoveries of S in fungicide and fertilizer samples were within the 84-109% range, and the relative standard deviation (n=12) was typically <5%.

  19. Detection of silver nanoparticles in parsley by solid sampling high-resolution-continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Feichtmeier, Nadine S; Leopold, Kerstin

    2014-06-01

    In this work, we present a fast and simple approach for detection of silver nanoparticles (AgNPs) in biological material (parsley) by solid sampling high-resolution-continuum source atomic absorption spectrometry (HR-CS AAS). A novel evaluation strategy was developed in order to distinguish AgNPs from ionic silver and for sizing of AgNPs. For this purpose, atomisation delay was introduced as significant indication of AgNPs, whereas atomisation rates allow distinction of 20-, 60-, and 80-nm AgNPs. Atomisation delays were found to be higher for samples containing silver ions than for samples containing silver nanoparticles. A maximum difference in atomisation delay normalised by the sample weight of 6.27 ± 0.96 s mg(-1) was obtained after optimisation of the furnace program of the AAS. For this purpose, a multivariate experimental design was used varying atomisation temperature, atomisation heating rate and pyrolysis temperature. Atomisation rates were calculated as the slope of the first inflection point of the absorbance signals and correlated with the size of the AgNPs in the biological sample. Hence, solid sampling HR-CS AAS was proved to be a promising tool for identifying and distinguishing silver nanoparticles from ionic silver directly in solid biological samples.

  20. [Determination of hydroxyproline in liver tissue by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry].

    Science.gov (United States)

    Liu, Wei; Qi, Shenglan; Xu, Ying; Xiao, Zhun; Fu, Yadong; Chen, Jiamei; Yang, Tao; Liu, Ping

    2017-12-08

    A method for the determination of hydroxyproline (Hyp) in liver tissue of mice by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry (HILIC-HRMS) was developed. The liver tissue samples of normal mice and liver fibrosis mice induced by carbon tetrachloride were hydrolyzed by concentrated hydrochloric acid. After filtrated and diluted by solution, the diluent was separated on an Hypersil GOLD HILIC column (100 mm×2.1 mm, 3 μm). Water-acetonitrile (28:72, v/v)were used as the mobile phases with isocratic elution. Finally, the target analytes were detected in positive model by HRMS equipped with an electrospray ionization source. The linear range of hydroxyproline was from 0.78 to 100.00 μg/L with the correlation coefficient ( R 2 ) of 0.9983. The limit of quantification was 0.78 μg/L. By detecting the spiked samples, the recoveries were in the range of 97.4%-100.9% with the relative standard deviations (RSDs) between 1.4% and 2.0%. In addition, comparison of the measurement results by this method and the chloramine T method was proceeded. It was found that the linear correlation between the two methods was very good, and the Pearson correlation coefficient was 0.927. And this method had simpler operation procedure and higher accuracy than chloramine T method. This method can be used for the quick determination of hydroxyproline in liver tissue samples.

  1. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  2. Oligomers, organosulfates, and nitrooxy organosulfates in rainwater identified by ultra-high resolution electrospray ionization FT-ICR mass spectrometry

    Directory of Open Access Journals (Sweden)

    K. E. Altieri

    2009-04-01

    Full Text Available Wet deposition is an important removal mechanism for atmospheric organic matter, and a potentially important input for receiving ecosystems, yet less than 50% of rainwater organic matter is considered chemically characterized. Precipitation samples collected in New Jersey, USA, were analyzed by negative ion ultra-high resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS. Elemental compositions of 552 unique molecular species were determined in the mass range 50–500 Da in the rainwater. Four main groups of organic compounds were identified: compounds containing carbon, hydrogen, and oxygen (CHO only, sulfur (S containing CHOS compounds, nitrogen (N containing CHON compounds, and S- and N- containing CHONS compounds. Organic acids commonly identified in precipitation were detected in the rainwater. Within the four main groups of compounds detected in the rainwater, oligomers, organosulfates, and nitrooxy-organosulfates were assigned based on elemental formula comparisons. The majority of the compounds identified are products of atmospheric reactions and are known contributors to secondary organic aerosol (SOA formed from gas phase, aerosol phase, and in-cloud reactions in the atmosphere. It is suggested that the large uncharacterized component of SOA is the main contributor to the large uncharacterized component of rainwater organic matter.

  3. Preliminary Determination of Natural Radioactivity Levels of the State of Qatar using High-Resolution Gamma-ray Spectrometry

    International Nuclear Information System (INIS)

    Al-Sulaiti, H.A.; Regan, P.H.; Bradley, D.A.; Matthews, M.; Santawamaitre, T.; Malain, D.

    2009-01-01

    The State of Qatar is a peninsula with a total area of 11,437 km 2 which lies over a geological formation comprising a sequence of limestone, chalk, clay and gypsum. Establishing a baseline for the radioactivity concentration in Qatar's soil is the main purpose behind the present study. The project is focused on obtaining measurements of representative soil samples from various areas in Qatar to establish concentrations of the 235 U, 238 U and 232 Th natural decay chains and also the long-lived naturally occurring radionuclide 40 K. The 235 U, 238 U, 232 Th and 40 K concentrations have been measured via high-resolution gamma-ray spectrometry using a hyper-pure germanium detector situated in a low-background environment with a copper inner-plated passive lead shield. A wide range of different gamma-ray energy transitions lines arising from the multiple decay products from the 235 U, 238 U and 232 Th decay chains have been analyzed separately to obtain more statistically significant overall results

  4. Localization of iron in rice grain using synchrotron X-ray fluorescence microscopy and high resolution secondary ion mass spectrometry

    KAUST Repository

    Kyriacou, Bianca

    2014-03-01

    Cereal crops accumulate low levels of iron (Fe) of which only a small fraction (5-10%) is bioavailable in human diets. Extensive co-localization of Fe in outer grain tissues with phytic acid, a strong chelator of metal ions, results in the formation of insoluble complexes that cannot be digested by humans. Here we describe the use of synchrotron X-ray fluorescence microscopy (XFM) and high resolution secondary ion mass spectrometry (NanoSIMS) to map the distribution of Fe, zinc (Zn), phosphorus (P) and other elements in the aleurone and subaleurone layers of mature grain from wild-type and an Fe-enriched line of rice (Oryza sativa L.). The results obtained from both XFM and NanoSIMS indicated that most Fe was co-localized with P (indicative of phytic acid) in the aleurone layer but that a small amount of Fe, often present as "hotspots", extended further into the subaleurone and outer endosperm in a pattern that was not co-localized with P. We hypothesize that Fe in subaleurone and outer endosperm layers of rice grain could be bound to low molecular weight chelators such as nicotianamine and/or deoxymugineic acid. © 2014.

  5. Localization of iron in rice grain using synchrotron X-ray fluorescence microscopy and high resolution secondary ion mass spectrometry

    KAUST Repository

    Kyriacou, Bianca; Moore, Katie L.; Paterson, David J.; De Jonge, Martin Daly; Howard, Daryl Lloyd; Stangoulis, James Constantine R; Tester, Mark A.; Lombi, E.; Johnson, Alexander A T

    2014-01-01

    Cereal crops accumulate low levels of iron (Fe) of which only a small fraction (5-10%) is bioavailable in human diets. Extensive co-localization of Fe in outer grain tissues with phytic acid, a strong chelator of metal ions, results in the formation of insoluble complexes that cannot be digested by humans. Here we describe the use of synchrotron X-ray fluorescence microscopy (XFM) and high resolution secondary ion mass spectrometry (NanoSIMS) to map the distribution of Fe, zinc (Zn), phosphorus (P) and other elements in the aleurone and subaleurone layers of mature grain from wild-type and an Fe-enriched line of rice (Oryza sativa L.). The results obtained from both XFM and NanoSIMS indicated that most Fe was co-localized with P (indicative of phytic acid) in the aleurone layer but that a small amount of Fe, often present as "hotspots", extended further into the subaleurone and outer endosperm in a pattern that was not co-localized with P. We hypothesize that Fe in subaleurone and outer endosperm layers of rice grain could be bound to low molecular weight chelators such as nicotianamine and/or deoxymugineic acid. © 2014.

  6. A sediment extraction and cleanup method for wide-scope multitarget screening by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Massei, Riccardo; Byers, Harry; Beckers, Liza-Marie; Prothmann, Jens; Brack, Werner; Schulze, Tobias; Krauss, Martin

    2018-01-01

    Previous studies on organic sediment contaminants focused mainly on a limited number of highly hydrophobic micropollutants accessible to gas chromatography using nonpolar, aprotic extraction solvents. The development of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) permits the spectrum of analysis to be expanded to a wider range of more polar and ionic compounds present in sediments and allows target, suspect, and nontarget screening to be conducted with high sensitivity and selectivity. In this study, we propose a comprehensive multitarget extraction and sample preparation method for characterization of sediment pollution covering a broad range of physicochemical properties that is suitable for LC-HRMS screening analysis. We optimized pressurized liquid extraction, cleanup, and sample dilution for a target list of 310 compounds. Finally, the method was tested on sediment samples from a small river and its tributaries. The results show that the combination of 100 °C for ethyl acetate-acetone (50:50, neutral extract) followed by 80 °C for acetone-formic acid (100:1, acidic extract) and methanol-10 mM sodium tetraborate in water (90:10, basic extract) offered the best extraction recoveries for 287 of 310 compounds. At a spiking level of 1 μg mL -1 , we obtained satisfactory cleanup recoveries for the neutral extract-(93 ± 23)%-and for the combined acidic/basic extracts-(42 ± 16)%-after solvent exchange. Among the 69 compounds detected in environmental samples, we successfully quantified several pharmaceuticals and polar pesticides.

  7. Determination of trace concentrations of chlorine in aqueous solutions by high-resolution continuum source graphite furnace molecular absorption spectrometry

    Science.gov (United States)

    Machyňák, Ľubomír; Čacho, František; Němeček, Martin; Beinrohr, Ernest

    2016-11-01

    Trace concentrations of total chlorine were determined by means of molecular absorption of indium mono-chloride (InCl) at 267.217 nm using high-resolution continuum source graphite furnace molecular absorption spectrometry. The effects of chemical modifiers and the amount of In on the sensitivity and accuracy were investigated. The optimum pyrolysis and vaporization temperatures were 600 °C and 1400 °C, respectively. The limit of detection and characteristic mass were found to be 0.10 ng and 0.21 ng, respectively. Potential non-spectral and spectral interferences were tested for various metals and non-metals at concentrations up to 50 mg L- 1 and for phosphoric, sulphuric and nitric acids. No spectral interferences were observed. Significant non-spectral interferences were observed with F, Br, and I at concentrations higher than 1 mg L- 1, 5 mg L- 1 and 25 mg L- 1, respectively, which is probably caused by formation of competitive indium halogen molecules. Higher concentrations of mineral acids depressed the signal owing to the formation of volatile HCl. The calibration curve was linear in the range between 0.3 and 10 ng with a correlation coefficient of R = 0.993. The elaborated method was used for the chlorine determination in various waters and a drug sample.

  8. Possibilities of High Resolution Inductively Coupled Plasma Optical Emission Spectrometry in the Determination of Trace Elements in Environmental Materials

    Directory of Open Access Journals (Sweden)

    Nikolaya Velitchkova

    2013-01-01

    Full Text Available This paper presents new quantitative data for the spectral interferences obtained by high resolution 40.68 MHz radial viewing inductively coupled plasma optical emission spectrometry (HR-ICP-OES in the determination of Zn, Cd, Sb, Cu, Mn, Pb, Sn, Cr, U, and Ba in environmental materials in the presence of a complex matrix, containing Al, Ca, Fe, Mg, and Ti. The -concept for quantification of spectral interferences was used. The optimum line selection for trace analysis of a variety of multicomponent matrices requires the choice of prominent lines, which are free or negligibly influenced by line interference problems. The versatility of -concept as basic methodology was experimentally demonstrated in the determination of trace of elements in soil and drinking water. The detection limits are lower in comparison with corresponding threshold concentration levels for soil and drinking water in accordance with environmental regulations. This paper shows the possibilities of present day ICP-OES equipment in the direct determination of trace elements (without preconcentration of impurities in environmental samples.

  9. Study of Grape Polyphenols by Liquid Chromatography-High-Resolution Mass Spectrometry (UHPLC/QTOF and Suspect Screening Analysis

    Directory of Open Access Journals (Sweden)

    Riccardo Flamini

    2015-01-01

    Full Text Available Suspect screening analysis is a targeted metabolomics method in which the identification of compounds relies on specific available information, such as their molecular formula and isotopic pattern. This method, coupled to liquid chromatography-high-resolution mass spectrometry, is effective in the study of grape metabolomics, in particular for characterization of flavonols, stilbene derivatives, and anthocyanins. For identification of compounds expected in the samples, a new database of putative compounds was expressly constructed by using the molecular information on potential metabolites of grape and wine from the literature and other electronic databases. Currently, this database contains around 1,100 compounds. The method allows identification of several hundred grape metabolites with two analyses (positive and negative ionization modes, and performing of data reprocessing using “untargeted” algorithms also provided the identification of some flavonols and resveratrol trimers and tetramers in grape for the first time. This approach can be potentially used in the study of metabolomics of varieties of other plant species.

  10. Molecular-level evidence provided by ultrahigh resolution mass spectrometry for oil-derived doc in groundwater at Bemidji, Minnesota

    Science.gov (United States)

    Islam, Ananna; Ahmed, Arif; Hur, Manhoi; Thorn, Kevin A.; Kim, Sunghwan

    2016-01-01

    Dissolved organic matter samples extracted from ground water at the USGS Bemidji oil spill site in Minnesota were investigated by ultrahigh resolution mass spectrometry. Principle component analysis (PCA) of the elemental composition assignments of the samples showed that the score plots for the contaminated sites were well separated from those for the uncontaminated sites. Additionally, spectra obtained from the same sampling site 7 and 19 years after the spill were grouped together in the score plot, strongly suggesting a steady state of contamination within the 12 year interval. The double bond equivalence (DBE) of Ox class compounds was broader for the samples from the contaminated sites, because of the complex nature of oil and the consequent formation of compounds with saturated and/or aromatic structures from the oxygenated products of oil. In addition, Ox class compounds with a relatively smaller number of x (x molecular-level signatures presented here can be a fundamental basis for in-depth analysis of oil contamination.

  11. Line width and line shape analysis in the inductively coupled plasma by high resolution Fourier transform spectrometry

    International Nuclear Information System (INIS)

    Faires, L.M.; Palmer, B.A.; Brault, J.W.

    1984-01-01

    High resolution Fourier transform spectrometry has been used to perform line width and line shape analysis of eighty-one iron I emision lines in the spectral range 290 to 390nm originating in the normal analytical zone of an inductively coupled plasma. Computer programs using non-linear least squares fitting techniques for line shape analysis were applied to the fully resolved spectra to determine Gaussian and Lorentzian components of the total observed line width. The effect of noise in the spectrum on the precision of the line fitting technique was assessed, and the importance of signal to noise ratio for line shape analysis is discussed. Translational (Doppler) temperatures were calculated from the Gaussian components of the line width and were found to be on the order of 6300 0 K. The excitation temperature of iron I was also determined from the same spectral data by the spectroscopic slope method based on the Einstein-Boltzmann expression for spectral intensity and was found to be on the order of 4700 0 K. 31 references

  12. Analysis of plutonium isotope ratios including 238Pu/239Pu in individual U-Pu mixed oxide particles by means of a combination of alpha spectrometry and ICP-MS.

    Science.gov (United States)

    Esaka, Fumitaka; Yasuda, Kenichiro; Suzuki, Daisuke; Miyamoto, Yutaka; Magara, Masaaki

    2017-04-01

    Isotope ratio analysis of individual uranium-plutonium (U-Pu) mixed oxide particles contained within environmental samples taken from nuclear facilities is proving to be increasingly important in the field of nuclear safeguards. However, isobaric interferences, such as 238 U with 238 Pu and 241 Am with 241 Pu, make it difficult to determine plutonium isotope ratios in mass spectrometric measurements. In the present study, the isotope ratios of 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu were measured for individual Pu and U-Pu mixed oxide particles by a combination of alpha spectrometry and inductively coupled plasma mass spectrometry (ICP-MS). As a consequence, we were able to determine the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu isotope ratios with ICP-MS after particle dissolution and chemical separation of plutonium with UTEVA resins. Furthermore, 238 Pu/ 239 Pu isotope ratios were able to be calculated by using both the 238 Pu/( 239 Pu+ 240 Pu) activity ratios that had been measured through alpha spectrometry and the 240 Pu/ 239 Pu isotope ratios determined through ICP-MS. Therefore, the combined use of alpha spectrometry and ICP-MS is useful in determining plutonium isotope ratios, including 238 Pu/ 239 Pu, in individual U-Pu mixed oxide particles. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. High resolution studies by Secondary Ion Mass Spectrometry of the spatial distribution of tritium in neutron irradiated beryllium pebbles

    International Nuclear Information System (INIS)

    Rabaglino, E.; Tamborini, G.; Hiernaut, J.-P.; Betti, M.

    2006-01-01

    A key issue of beryllium as a neutron multiplier in the blanket of future fusion reactors is tritium retention. Models are under development in order to predict tritium release kinetics in the typical operating conditions of the material in the blanket: the absence of experimental data in this range imposes an extrapolation of the models, therefore a detailed characterization and understanding of microscopic diffusion phenomena related to macroscopic tritium release is necessary. It has been recently shown, that the availability of evidence on such phenomena at a scale of 1 micron down to tens of nanometers enables a relevant progress in the effectiveness of model validation: therefore the need for applying and developing advanced analytical techniques based on mass spectrometry at this scale. A study of tritium spatial distribution in neutron irradiated beryllium pebbles (2 mm diameter, 480 appm 4 He, 7 appm 3 H) by means of Secondary Ion Mass Spectrometry (SIMS) is presented. Samples in different conditions (non-irradiated, at end of irradiation and at different temperatures during thermal ramp annealing) are examined by an oxygen ion primary beam with a spatial resolution of 1 micron along a diameter. The sample preparation is optimized in order to enable a quantitative comparison among the different conditions. Under an oxygen ion beam tritium is detected in the irradiated samples in a molecular form (3H 2 ), with a continuous distribution inside the grains, which suggests the presence of small clusters in agreement with TEM analyses, and in the form of peaks at grain boundaries, corresponding to large grain boundary bubbles. The evolving of molecular tritium distribution measured by SIMS during a typical thermal ramp release experiment shows precisely tritium diffusion from the centre of the grain to grain boundaries as the temperature increases: at the same time the remaining intragranular tritium inventory, given by the integral of the distribution

  14. Identification of organic nitrates in the NO3 radical initiated oxidation of alpha-pinene by atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Perraud, Véronique; Bruns, Emily A; Ezell, Michael J; Johnson, Stanley N; Greaves, John; Finlayson-Pitts, Barbara J

    2010-08-01

    The gas-phase reactions of nitrate radicals (NO3) with biogenic organic compounds are a major sink for these organics during night-time. These reactions form secondary organic aerosols, including organic nitrates that can undergo long-range transport, releasing NOx downwind. We report here studies of the reaction of NO3 with alpha-pinene at 1 atm in dry synthetic air (relative humidity approximately 3%) and at 298 K using atmospheric pressure chemical ionization triple quadrupole mass spectrometry (APCI-MS) to identify gaseous and particulate products. The emphasis is on the identification of individual organic nitrates in the particle phase that were obtained by passing the product mixture through a denuder to remove gas-phase reactants and products prior to entering the source region of the mass spectrometer. Filter extracts were also analyzed by GC-MS and by APCI time-of-flight mass spectrometry (APCI-ToF-MS) with methanol as the proton source. In addition to pinonaldehyde and pinonic acid, five organic nitrates were identified in the particles as well as in the gas phase: 3-oxopinane-2-nitrate, 2-hydroxypinane-3-nitrate, pinonaldehyde-PAN, norpinonaldehyde-PAN, and (3-acetyl-2,2-dimethyl-3-nitrooxycyclobutyl)acetaldehyde. Furthermore, there was an additional first-generation organic nitrate product tentatively identified as a carbonyl hydroxynitrate with a molecular mass of 229. These studies suggest that a variety of organic nitrates would partition between the gas phase and particles in the atmosphere, and serve as a reservoir for NOx.

  15. Separation and activity determination of 239+240Pu, 241Am and Curium (242and244Cm) in evaporator concentrate by Alpha Spectrometry

    International Nuclear Information System (INIS)

    Reis Junior, Aluisio S.; Temba, Eliane S.C.; Kastner, Geraldo F.; Monteiro, Roberto P.G.

    2013-01-01

    Alpha spectrometry analysis was used for activity determinations of Pu, Am and Cm isotopes in evaporator concentrate samples from nuclear power plants. Using a sequential procedure the first step was Pu isolation by an anion exchange column followed by an Am and Cm separation of U and Fe by a co-precipitation with oxalic acid. The precipitate was used for americium and curium separation of strontium by using a TRU resin extraction chromatography column. Due to their chemical similarities and energy difference it was seen that the simultaneous determination of 241 Am, 242 Cm and 24 3 ,244 Cm isotopes is possible using the 243 Am as tracer, once they have peaks in different region of interest (ROI) in the alpha spectrum. In this work it was used tracers, 238 Pu, 243 Am, 244 Cm and 232 U, for determination and quantification of theirs isotopes, respectively. The standard deviations for replicate analysis were calculated and for 241 Am it was (1,040 ± 160 mBqKg -1 ), relative standard deviation 15.38%, and for 239+240 Pu it was (551 +- 44 mBqKg -1 ), relative standard deviation 7.98%. In addition, for the 242 Cm isotope the standard deviation for determinations was(75 ± 23 mBqKg -1 ), with the relative standard deviation 30.67% higher than for 241 Am and 239+240 Pu. The radiometric yields ranged from 90% to 105% and the lower limit of detection was estimated as being 2.05 mBqKg -1 . (author)

  16. Review: LC coupled to low- and high-resolution mass spectrometry for new psychoactive substance screening in biological matrices - Where do we stand today?

    Science.gov (United States)

    Meyer, Markus R; Maurer, Hans H

    2016-07-13

    The field of new psychoactive substances (NPS) is highly dynamic and the situation changes from year to year. Therefore, the current review provides a timely update about the latest developments to help analysts keep the pace with NPS distribution. It covers PubMed-listed studies published between January 2014 and January 2016 dealing with the application of liquid chromatography (LC) coupled low- and high-resolution mass spectrometry (MS) for broad screenings for NPS in clinical (CT) and forensic (FT) toxicology. Latest developments and applications are highlighted and selected papers critically discussed. Comprehensive tables summarizing all discussed articles complete the overview. Finally, an outlook on the future of LC coupled MS in CT and FT is provided and readers will learn why low-resolution mass spectrometry might remain the standard for the next couple of years at least for easy-to-use quantitative screening procedures. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The coupling of supercritical fluid chromatography and field ionization time-of-flight high-resolution mass spectrometry for rapid and quantitative analysis of petroleum middle distillates.

    Science.gov (United States)

    Qian, Kuangnan; Diehl, John W; Dechert, Gary J; DiSanzo, Frank P

    2004-01-01

    We report the first coupling of supercritical fluid chromatography (SFC) with field ionization time-of-flight high-resolution mass spectrometry (FI-ToF HRMS), in parallel with ultraviolet (UV) detection and flame ionization detection (FID), for rapid and quantitative analysis of petroleum middle distillates. SFC separates petroleum middle distillates into saturates and 1- to 3-ring aromatics. FI generates molecular ions for hydrocarbon species eluted from the SFC. The high resolution and exact mass measurements by ToF mass spectrometry provide elemental compositions of the molecules in the petroleum product. The amounts of saturates and aromatic ring types were quantified using the parallel SFC-FID assisted by SFC-UV. With a proper carbon-number calibration, the detailed composition of the petroleum middle distillate was rapidly determined.

  18. Time‐of‐flight secondary ion mass spectrometry imaging of biological samples with delayed extraction for high mass and high spatial resolutions

    Science.gov (United States)

    Vanbellingen, Quentin P.; Elie, Nicolas; Eller, Michael J.; Della‐Negra, Serge; Touboul, David

    2015-01-01

    Rationale In Time‐of‐Flight Secondary Ion Mass Spectrometry (TOF‐SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF‐SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a mass resolution of several thousand or a sub‐µm lateral resolution, but the combination of both is generally not possible. Methods With a TOF‐SIMS setup, a delayed extraction applied to secondary ions has been studied extensively on rat cerebellum sections in order to compensate for the effect of long primary ion bunches. Results The use of a delayed extraction has been proven to be an efficient solution leading to unique features, i.e. a mass resolution up to 10000 at m/z 385.4 combined with a lateral resolution of about 400 nm. Simulations of ion trajectories confirm the experimental determination of optimal delayed extraction and allow understanding of the behavior of ions as a function of their mass‐to‐charge ratio. Conclusions Although the use of a delayed extraction has been well known for many years and is very popular in MALDI, it is much less used in TOF‐SIMS. Its full characterization now enables secondary ion images to be recorded in a single run with a submicron spatial resolution and with a mass resolution of several thousand. This improvement is very useful when analyzing lipids on tissue sections, or rare, precious, or very small size samples. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. PMID:26395603

  19. Simultaneous determinations of uranium, thorium, and plutonium in soft tissues by solvent extraction and alpha-spectrometry

    International Nuclear Information System (INIS)

    Singh, N.P.; Zimmerman, C.J.; Lewis, L.L.; Wrenn, M.E.

    1984-01-01

    A radiochemical procedure for the simultaneous determination of uranium, thorium, and plutonium, in soft tissues has been developed. The weighed amounts of tissues, spiked with 232 U, 242 Pu, and 229 th tracers, are wet ashed. Uranium, thorium, and plutonium are coprecipitated with iron as hydroxides, dissolved in concentrated HCl and the acidity adjusted to 10 M. Uranium and plutonium are extracted into 20% TLA solution in xylene, leaving thorium in the aqueous phase. Plutonium is back-extracted by reducing to the trivalent state with 0.05 M NH 4 I solution in 8 M HCl, and uranium is back-extracted with 0.1 M HCl. Thorium is extracted into 20% TLA solution from 4 M HNO 3 and back-extracted with 10 M HCl. Uranium, thorium and plutonium are electrodeposited separately onto platinum discs and counted alpha-spectrometrically using surface barrier silicon diodes and a multichannel analyzer. The method was developed using bovine liver and applied to dog and human tissues. The mean radiochemical recoveries of these actinides in different organs were better than 70%. 6 references, 2 tables

  20. Rapid non-destructive quantitative estimation of urania/ thoria in mixed thorium uranium di-oxide pellets by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shriwastwa, B.B.; Kumar, Anil; Raghunath, B.; Nair, M.R.; Abani, M.C.; Ramachandran, R.; Majumdar, S.; Ghosh, J.K.

    2001-01-01

    A non-destructive technique using high-resolution gamma-ray spectrometry has been standardised for quantitative estimation of uranium/thorium in mixed (ThO 2 -UO 2 ) fuel pellets of varying composition. Four gamma energies were selected; two each from the uranium and thorium series and the time of counting has been optimised. This technique can be used for rapid estimation of U/Th percentage in a large number of mixed fuel pellets from a production campaign

  1. Development of High Resolution Resonance Ionization Mass Spectrometry for Neutron Dosimetry Technique with93Nb(n,n'93mNb Reaction

    Directory of Open Access Journals (Sweden)

    Tomita Hideki

    2016-01-01

    Full Text Available We have proposed an advanced technique to measure the 93mNb yield precisely by Resonance Ionization Mass Spectrometry, instead of conventional characteristic X-ray spectroscopy. 93mNb-selective resonance ionization is achievable by distinguishing the hyperfine splitting of the atomic energy levels between 93Nb and 93mNb at high resolution. In advance of 93mNb detection, we could successfully demonstrate high resolution resonant ionization spectroscopy of stable 93Nb using an all solid-state, narrow-band and tunable Ti:Sapphire laser system operated at 1 kHz repetition rate.

  2. The Characterization of Laser Ablation Patterns and a New Definition of Resolution in Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry (MALDI-IMS).

    Science.gov (United States)

    O'Rourke, Matthew B; Raymond, Benjamin B A; Padula, Matthew P

    2017-05-01

    Matrix assisted laser desorption ionization imaging mass spectrometry (MALDI-IMS) is a technique that has seen a sharp rise in both use and development. Despite this rapid adoption, there have been few thorough investigations into the actual physical mechanisms that underlie the acquisition of IMS images. We therefore set out to characterize the effect of IMS laser ablation patterns on the surface of a sample. We also concluded that the governing factors that control spatial resolution have not been correctly defined and therefore propose a new definition of resolution. Graphical Abstract ᅟ.

  3. A four dimensional separation method based on continuous heart-cutting gas chromatography with ion mobility and high resolution mass spectrometry.

    Science.gov (United States)

    Lipok, Christian; Hippler, Jörg; Schmitz, Oliver J

    2018-02-09

    A two-dimensional GC (2D-GC) method was developed and coupled to an ion mobility-high resolution mass spectrometer, which enables the separation of complex samples in four dimensions (2D-GC, ion mobilility spectrometry and mass spectrometry). This approach works as a continuous multiheart-cutting GC-system (GC+GC), using a long modulation time of 20s, which allows the complete transfer of most of the first dimension peaks to the second dimension column without fractionation, in comparison to comprehensive two-dimensional gas chromatography (GCxGC). Hence, each compound delivers only one peak in the second dimension, which simplifies the data handling even when ion mobility spectrometry as a third and mass spectrometry as a fourth dimension are introduced. The analysis of a plant extract from Calendula officinales shows the separation power of this four dimensional separation method. The introduction of ion mobility spectrometry provides an additional separation dimension and allows to determine collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 800 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Screening for exogenous androgen anabolic steroids in human hair by liquid chromatography/orbitrap-high resolution mass spectrometry

    International Nuclear Information System (INIS)

    Strano-Rossi, Sabina; Castrignanò, Erika; Anzillotti, Luca; Odoardi, Sara; De-Giorgio, Fabio; Bermejo, Ana; Pascali, Vincenzo L.

    2013-01-01

    Graphical abstract: -- Highlights: •LC–HRMS screening method for the detection of a variety of anabolics in hair. •Detection of unmetabolized anabolic steroids and their esters in hair matrix by simple keratin pretreatment. •Identification of target compounds by retention time, accurate mass and isotopic cluster. •Quantitative determination of detected compounds. •Possibility to a retrospective re-analysis of the acquired datafile in case a further analyte is to be screened. -- Abstract: A method for the screening of various anabolic steroids and their esters in human hair, based on liquid-chromatography–high resolution mass spectrometry using an Exactive benchtop Orbitrap mass spectrometer, has been set up and validated. This method involved methanolic incubation of 30 mg of hair and analysis of the relevant extract in HPLC using a C18 column. The mass detector, with nominal resolving power of 100,000, operated in full scan mode in APCI under positive ionization mode. Analytes were identified by exact mass, correspondence of isotopic cluster and retention times. The limits of detection obtained varied from 10 to 50 pg mg −1 , and limits of quantitation were 0.5 ng mg −1 for all compounds. The method was linear for all analytes in the ranges from the LOQ to 6 ng mg −1 , giving correlation coefficients >0.99 for all analytes. Also accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Specificity was assessed by analysing ten blank samples and fifteen samples from polidrug abusers. This method was applied to a real-life case, resulting in the identification of testosterone undecanoate in the hair of a suspect. The analyte identity was confirmed by the analysis of its in-source fragmentation and comparison to a certified standard. Thanks to the scan acquisition, this method also enables retrospective re-analysis of the acquired datafile in case a further analyte needs to be screened

  5. Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry.

    Science.gov (United States)

    Boudah, Samia; Olivier, Marie-Françoise; Aros-Calt, Sandrine; Oliveira, Lydie; Fenaille, François; Tabet, Jean-Claude; Junot, Christophe

    2014-09-01

    This work aims at evaluating the relevance and versatility of liquid chromatography coupled to high resolution mass spectrometry (LC/HRMS) for performing a qualitative and comprehensive study of the human serum metabolome. To this end, three different chromatographic systems based on a reversed phase (RP), hydrophilic interaction chromatography (HILIC) and a pentafluorophenylpropyl (PFPP) stationary phase were used, with detection in both positive and negative electrospray modes. LC/HRMS platforms were first assessed for their ability to detect, retain and separate 657 metabolite standards representative of the chemical families occurring in biological fluids. More than 75% were efficiently retained in either one LC-condition and less than 5% were exclusively retained by the RP column. These three LC/HRMS systems were then evaluated for their coverage of serum metabolome. The combination of RP, HILIC and PFPP based LC/HRMS methods resulted in the annotation of about 1328 features in the negative ionization mode, and 1358 in the positive ionization mode on the basis of their accurate mass and precise retention time in at least one chromatographic condition. Less than 12% of these annotations were shared by the three LC systems, which highlights their complementarity. HILIC column ensured the greatest metabolome coverage in the negative ionization mode, whereas PFPP column was the most effective in the positive ionization mode. Altogether, 192 annotations were confirmed using our spectral database and 74 others by performing MS/MS experiments. This resulted in the formal or putative identification of 266 metabolites, among which 59 are reported for the first time in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Determination of BMAA and three alkaloid cyanotoxins in lake water using dansyl chloride derivatization and high-resolution mass spectrometry.

    Science.gov (United States)

    Roy-Lachapelle, Audrey; Solliec, Morgan; Sauvé, Sébastien

    2015-07-01

    A new analytical method was developed for the detection of alkaloid cyanotoxins in harmful algal blooms. The detection of the nonproteinogenic amino acid β-N-methylamino-L-alanine (BMAA) and two of its conformation isomers, 2,4-diaminobutyric acid (DAB) and N-(2-aminoethyl) glycine (AEG), as well as three alkaloid cyanotoxins, anatoxin-a (ANA-a), cylindrospermopsin (CYN), and saxitoxin (STX), is presented. The use of a chemical derivatization with dansyl chloride (DNS) allows easier separation with reversed phase liquid chromatography. Detection with high-resolution mass spectrometry (HRMS) with the Q-Exactive enables high selectivity with specific fragmentation as well as exact mass detection, reducing considerably the possibilities of isobaric interferences. Previous to analysis, a solid phase extraction (SPE) step is used for purification and preconcentration. After DNS derivatization, samples are submitted to ultra high-performance liquid chromatography coupled with heated electrospray ionisation and the Q-Exactive mass spectrometer (UHPLC-HESI-HRMS). With an internal calibration using isotopically-labeled DAB-D3, the method was validated with good linearity (R (2)  > 0.998), and method limits of detection and quantification (MLD and MLQ) for target compounds ranged from 0.007 to 0.01 μg L(-1) and from 0.02 to 0.04 μg L(-1), respectively. Accuracy and within-day/between-days variation coefficients were below 15%. SPE recovery values ranged between 86 and 103%, and matrix effects recovery values ranged between 75 and 96%. The developed analytical method was successfully validated with 12 different lakes samples, and concentrations were found ranging between 0.009 and 0.3 μg L(-1) except for STX which was not found in any sample.

  7. An integrated strategy for in vivo metabolite profiling using high-resolution mass spectrometry based data processing techniques

    International Nuclear Information System (INIS)

    Guo, Jian; Zhang, Minli; Elmore, Charles S.; Vishwanathan, Karthick

    2013-01-01

    Graphical abstract: -- Highlights: •Profiling the metabolites of model compounds in rats using high resolution mass spectrometry based data processing techniques. •Demonstrating an integrated strategy in vivo metabolite profiling using data mining tools. •Unusual metabolites generated via thiazole-ring opening were characterized based on processed LC–MS.data. -- Abstract: An ongoing challenge of drug metabolite profiling is to detect and identify unknown or low-level metabolites in complex biological matrices. Here we present a generic strategy for metabolite detection using multiple accurate-mass-based data processing tools via the analysis of rat samples of two model drug candidates, AZD6280 and AZ12488024. First, the function of isotopic pattern recognition was proved to be highly effective in the detection of metabolites derived from [ 14 C]-AZD6280 that possesses a distinct isotopic pattern. The metabolites revealed using this approach were in excellent qualitative correlation to those observed in radiochromatograms. Second, the effectiveness of accurate mass based untargeted data mining tools such as background subtraction, mass defect filtering, or a data mining package (MZmine) used for metabolomic analysis in detection of metabolites of [ 14 C]-AZ12488024 in rat urine, feces, bile and plasma samples was examined and a total of 33 metabolites of AZ12488024 were detected. Among them, at least 16 metabolites were only detected by the aid of the data mining packages and not via radiochromatograms. New metabolic pathways such as S-oxidation and thiomethylation reactions occurring on the thiazole ring were proposed based on the processed data. The results of these experiments also demonstrated that accurate mass-based mass defect filtering (MDF) and data mining techniques used in metabolomics are complementary and can be valuable tools for delineating low-level metabolites in complex matrices. Furthermore, the application of distinct multiple data

  8. Screening halogenated environmental contaminants in biota based on isotopic pattern and mass defect provided by high resolution mass spectrometry profiling

    Energy Technology Data Exchange (ETDEWEB)

    Cariou, Ronan, E-mail: laberca@oniris-nantes.fr; Omer, Elsa; Léon, Alexis; Dervilly-Pinel, Gaud; Le Bizec, Bruno

    2016-09-14

    In the present work, we addressed the question of global seeking/screening organohalogenated compounds in a large panel of complex biological matrices, with a particular focus on unknown chemicals that may be considered as potential emerging hazards. A fishing strategy was developed based on untargeted profiling among full scan acquisition datasets provided by high resolution mass spectrometry. Since large datasets arise from such profiling, filtering useful information stands as a central question. In this way, we took advantage of the exact mass differences between Cl and Br isotopes. Indeed, our workflow involved an innovative Visual Basic for Applications script aiming at pairing features according to this mass difference, in order to point out potential organohalogenated clusters, preceded by an automated peak picking step based on the centWave function (xcms package of open access R programming environment). Then, H/Cl-scale mass defect plots were used to visualize the datasets before and after filtering. The filtering script was successfully applied to a dataset generated upon liquid chromatography coupled to ESI(−)-HRMS measurement from one eel muscle extract, allowing for realistic manual investigations of filtered clusters. Starting from 9789 initial obtained features, 1994 features were paired in 589 clusters. Hexabromocyclododecane, chlorinated paraffin series and various other compounds have been identified or tentatively identified, allowing thus broad screening of organohalogenated compounds in this extract. Although realistic, manual review of paired clusters remains time consuming and much effort should be devoted to automation. - Highlights: • We address the screening of halogenated compounds in large Full Scan HRMS datasets. • The workflow involves peak picking, pairing script and review of paired features. • The pairing script is based on exact mass differences between Cl and Br isotopes. • H/Cl scale mass defect plots are used to

  9. Direct surface analysis coupled to high-resolution mass spectrometry reveals heterogeneous composition of the cuticle of Hibiscus trionum petals.

    Science.gov (United States)

    Giorio, Chiara; Moyroud, Edwige; Glover, Beverley J; Skelton, Paul C; Kalberer, Markus

    2015-10-06

    Plant cuticle, which is the outermost layer covering the aerial parts of all plants including petals and leaves, can present a wide range of patterns that, combined with cell shape, can generate unique physical, mechanical, or optical properties. For example, arrays of regularly spaced nanoridges have been found on the dark (anthocyanin-rich) portion at the base of the petals of Hibiscus trionum. Those ridges act as a diffraction grating, producing an iridescent effect. Because the surface of the distal white region of the petals is smooth and noniridescent, a selective chemical characterization of the surface of the petals on different portions (i.e., ridged vs smooth) is needed to understand whether distinct cuticular patterns correlate with distinct chemical compositions of the cuticle. In the present study, a rapid screening method has been developed for the direct surface analysis of Hibiscus trionum petals using liquid extraction surface analysis (LESA) coupled with high-resolution mass spectrometry. The optimized method was used to characterize a wide range of plant metabolites and cuticle monomers on the upper (adaxial) surface of the petals on both the white/smooth and anthocyanic/ridged regions, and on the lower (abaxial) surface, which is entirely smooth. The main components detected on the surface of the petals are low-molecular-weight organic acids, sugars, and flavonoids. The ridged portion on the upper surface of the petal is enriched in long-chain fatty acids, which are constituents of the wax fraction of the cuticle. These compounds were not detected on the white/smooth region of the upper petal surface or on the smooth lower surface.

  10. Electrospray Ionization with High-Resolution Mass Spectrometry as a Tool for Lignomics: Lignin Mass Spectrum Deconvolution

    Science.gov (United States)

    Andrianova, Anastasia A.; DiProspero, Thomas; Geib, Clayton; Smoliakova, Irina P.; Kozliak, Evguenii I.; Kubátová, Alena

    2018-05-01

    The capability to characterize lignin, lignocellulose, and their degradation products is essential for the development of new renewable feedstocks. Electrospray ionization high-resolution time-of-flight mass spectrometry (ESI-HR TOF-MS) method was developed expanding the lignomics toolkit while targeting the simultaneous detection of low and high molecular weight (MW) lignin species. The effect of a broad range of electrolytes and various ionization conditions on ion formation and ionization effectiveness was studied using a suite of mono-, di-, and triarene lignin model compounds as well as kraft alkali lignin. Contrary to the previous studies, the positive ionization mode was found to be more effective for methoxy-substituted arenes and polyphenols, i.e., species of a broadly varied MW structurally similar to the native lignin. For the first time, we report an effective formation of multiply charged species of lignin with the subsequent mass spectrum deconvolution in the presence of 100 mmol L-1 formic acid in the positive ESI mode. The developed method enabled the detection of lignin species with an MW between 150 and 9000 Da or higher, depending on the mass analyzer. The obtained M n and M w values of 1500 and 2500 Da, respectively, were in good agreement with those determined by gel permeation chromatography. Furthermore, the deconvoluted ESI mass spectrum was similar to that obtained with matrix-assisted laser desorption/ionization (MALDI)-HR TOF-MS, yet featuring a higher signal-to-noise ratio. The formation of multiply charged species was confirmed with ion mobility ESI-HR Q-TOF-MS. [Figure not available: see fulltext.

  11. Screening halogenated environmental contaminants in biota based on isotopic pattern and mass defect provided by high resolution mass spectrometry profiling

    International Nuclear Information System (INIS)

    Cariou, Ronan; Omer, Elsa; Léon, Alexis; Dervilly-Pinel, Gaud; Le Bizec, Bruno

    2016-01-01

    In the present work, we addressed the question of global seeking/screening organohalogenated compounds in a large panel of complex biological matrices, with a particular focus on unknown chemicals that may be considered as potential emerging hazards. A fishing strategy was developed based on untargeted profiling among full scan acquisition datasets provided by high resolution mass spectrometry. Since large datasets arise from such profiling, filtering useful information stands as a central question. In this way, we took advantage of the exact mass differences between Cl and Br isotopes. Indeed, our workflow involved an innovative Visual Basic for Applications script aiming at pairing features according to this mass difference, in order to point out potential organohalogenated clusters, preceded by an automated peak picking step based on the centWave function (xcms package of open access R programming environment). Then, H/Cl-scale mass defect plots were used to visualize the datasets before and after filtering. The filtering script was successfully applied to a dataset generated upon liquid chromatography coupled to ESI(−)-HRMS measurement from one eel muscle extract, allowing for realistic manual investigations of filtered clusters. Starting from 9789 initial obtained features, 1994 features were paired in 589 clusters. Hexabromocyclododecane, chlorinated paraffin series and various other compounds have been identified or tentatively identified, allowing thus broad screening of organohalogenated compounds in this extract. Although realistic, manual review of paired clusters remains time consuming and much effort should be devoted to automation. - Highlights: • We address the screening of halogenated compounds in large Full Scan HRMS datasets. • The workflow involves peak picking, pairing script and review of paired features. • The pairing script is based on exact mass differences between Cl and Br isotopes. • H/Cl scale mass defect plots are used to

  12. Advanced Collimators for Verification of the Pu Isotopic Composition in Fresh Fuel by High Resolution Gamma Spectrometry

    International Nuclear Information System (INIS)

    Lebrun, Alain; Berlizov, Andriy

    2013-06-01

    IAEA verification of the nuclear material contained in fresh nuclear fuel assemblies is usually based on neutron coincidence counting (NCC). In the case of uranium fuel, active NCC provides the total content of uranium-235 per unit of length which, combined with active length verification, fully supports the verification. In the case of plutonium fuel, passive NCC provides the plutonium-240 equivalent content which needs to be associated with a measurement of the isotopic composition and active length measurement to complete the verification. Plutonium isotopic composition is verified by high resolution gamma spectrometry (HRGS) applied on fresh fuel assemblies assuming all fuel rods are fabricated from the same plutonium batch. For particular verifications when such an assumption cannot be reasonably made, there is a need to optimize the HRGS measurement so that contributions of internal rods to the recorded spectrum are maximized, thus providing equally strong verification of the internal fuel rods. This paper reports on simulation work carried out to design special collimators aimed at reducing the relative contribution of external fuel rods while enhancing the signal recorded from internal rods. Both cases of square lattices (e.g. 17x17 pressurized water reactor (PWR) fuel) and hexagonal compact lattices (e.g. BN800 fast neutron reactor (FNR) fuel) have been addressed. In the case of PWR lattices, the relatively large optical path to internal pins compensates for low plutonium concentrations and the large size of the fuel assemblies. A special collimator based on multiple, asymmetrical, vertical slots allows recording a spectrum from internal rods only when needed. In the FNR case, the triangular lattice is much more compact and the optical path to internal rods is very narrow. However, higher plutonium concentration and use of high energy ranges allow the verification of internal rods to be significantly strengthened. Encouraging results from the simulation

  13. Comparative analysis of native and permethylated human milk oligosaccharides by liquid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Oursel, Stéphanie; Cholet, Sophie; Junot, Christophe; Fenaille, François

    2017-12-15

    Human milk oligosaccharides (HMOs) represent the third most abundant components of milk after lactose and lipids. HMOs are indigestible by the suckling infant but can act as prebiotics and have significant biological functions regarding the organism defense against pathogens (such as bacteria or viruses) by preventing interactions with their receptors. Although constituted of only five distinct monosaccharide building blocks, HMOs are highly structurally diverse compounds with many co-existing structural isomers. Here we report the development and comparison of two distinct glycomic platforms based on liquid chromatography coupled to high resolution mass spectrometry (LC-MS) for analyzing HMOs. We have implemented and thoroughly compared the LC-MS of permethylated and native HMOs on reversed phase (RP) and porous graphitic carbon (PGC) columns for their ability to resolve the natural heterogeneity of milk oligosaccharides at the highest sensitivity. Our data essentially underlines the usefulness of analyzing HMOs as permethylated derivatives especially for getting more precise structural information at high sensitivity. For instance, permethylation annihilates gas-phase fucose migration during MS/MS experiments, thus facilitating spectra interpretation and giving access to relevant information regarding oligosaccharide branching and isomer distinction. At the opposite, LC-MS profiling of native HMOs (using PGC) in milk performed best in terms of detected species, while also being much faster in terms of sample preparation. Although less efficient than PGC chromatography, RPLC proved successful for separating pairs of permethylated isomeric HMOs. A key advantage of RP over PGC liquid chromatography is that retention times can be correlated to molecular weights, which can greatly facilitate further HMO identification using retention time prediction. Altogether these data lead us to think that LC-MS analysis of native HMOs (using PGC) can be used as first

  14. Screening for exogenous androgen anabolic steroids in human hair by liquid chromatography/orbitrap-high resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Strano-Rossi, Sabina, E-mail: sabina.stranorossi@rm.unicatt.it [Institute of Legal Medicine, Catholic University of Sacred Heart, L.go F. Vito, 1, 00168 Rome (Italy); Castrignanò, Erika; Anzillotti, Luca; Odoardi, Sara; De-Giorgio, Fabio [Institute of Legal Medicine, Catholic University of Sacred Heart, L.go F. Vito, 1, 00168 Rome (Italy); Bermejo, Ana [Institute of Legal Medicine, University of Santiago de Compostela, Av S. Francisco s/n, Santiago de Compostela (Spain); Pascali, Vincenzo L. [Institute of Legal Medicine, Catholic University of Sacred Heart, L.go F. Vito, 1, 00168 Rome (Italy)

    2013-09-02

    Graphical abstract: -- Highlights: •LC–HRMS screening method for the detection of a variety of anabolics in hair. •Detection of unmetabolized anabolic steroids and their esters in hair matrix by simple keratin pretreatment. •Identification of target compounds by retention time, accurate mass and isotopic cluster. •Quantitative determination of detected compounds. •Possibility to a retrospective re-analysis of the acquired datafile in case a further analyte is to be screened. -- Abstract: A method for the screening of various anabolic steroids and their esters in human hair, based on liquid-chromatography–high resolution mass spectrometry using an Exactive benchtop Orbitrap mass spectrometer, has been set up and validated. This method involved methanolic incubation of 30 mg of hair and analysis of the relevant extract in HPLC using a C18 column. The mass detector, with nominal resolving power of 100,000, operated in full scan mode in APCI under positive ionization mode. Analytes were identified by exact mass, correspondence of isotopic cluster and retention times. The limits of detection obtained varied from 10 to 50 pg mg{sup −1}, and limits of quantitation were 0.5 ng mg{sup −1} for all compounds. The method was linear for all analytes in the ranges from the LOQ to 6 ng mg{sup −1}, giving correlation coefficients >0.99 for all analytes. Also accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Specificity was assessed by analysing ten blank samples and fifteen samples from polidrug abusers. This method was applied to a real-life case, resulting in the identification of testosterone undecanoate in the hair of a suspect. The analyte identity was confirmed by the analysis of its in-source fragmentation and comparison to a certified standard. Thanks to the scan acquisition, this method also enables retrospective re-analysis of the acquired datafile in case a further analyte needs to be screened.

  15. Hydrophilic interaction liquid chromatography coupled to high-resolution mass spectrometry to determine artificial sweeteners in environmental waters.

    Science.gov (United States)

    Salas, Daniela; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa Maria

    2015-06-01

    Artificial sweeteners are food additives employed as sugar substitutes which are now considered to be emerging organic contaminants. In the present study, a method is developed for the determination of a group of artificial sweeteners in environmental waters. Considering the polar and hydrophilic character of these compounds, hydrophilic interaction liquid chromatography is proposed for their separation as an alternative to traditional reversed-phase liquid chromatography. Two stationary phases with different chemistry were compared for this purpose. For the detection of the analytes, high-resolution mass spectrometry (Orbitrap) was employed to take advantage of its benefits in terms of reliable quantification and confirmation for the measurement of accurate masses. Solid-phase extraction was chosen as the sample treatment, in which the extract in a mixture of NH4OH:MeOH:ACN (1:4:15) was directly injected into the chromatographic system, simplifying the analytical procedure. The optimized method was validated on river and waste water samples. For example, in the case of effluent water samples, limits of detection ranged from 0.002 to 0.7 μg/L and limits of quantification ranged from 0.004 to 1.5 μg/L. Apparent (whole method) recoveries ranged from 57 to 74% with intra-day precision (%RSD, n = 5) ranging from 6 to 25%. The method was successfully applied to water samples from different rivers in Catalonia and different waste water treatment plants in Tarragona. Acesulfame, cyclamate, saccharine and sucralose were found in several samples.

  16. Determination of 137Cs activity in soil from Qatar using high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Al-Sulaiti, Huda; Nasir, Tabassum; Al Mugren, K.S.; Alkhomashi, N.; Al-Dahan, N.; Al-Dosari, M.; Bradley, D.A.; Bukhari, S.; Matthews, M.; Regan, P.H.; Santawamaitre, T.; Malain, D.; Habib, A.; Al-Dosari, Hanan; Al Sadig, Ibrahim

    2016-01-01

    With interest in establishing baseline concentrations of 137 Cs in soil from the Qatarian peninsula, we focus on determination of the activity concentrations in 129 soil samples collected across the State of Qatar prior to the 2011 Fukushima Dai-ichi nuclear power plant accident. As such, the data provides the basis of a reference map for the detection of releases of this fission product. The activity concentrations were measured via high-resolution gamma-ray spectrometry using a hyper-pure germanium detector enclosed in a copper-lined passive lead shield that was situated in a low-background environment. The activity concentrations ranged from 0.21 to 15.41 Bq/kg, with a median value of 1 Bq/kg, the greatest activity concentration being observed in a sample obtained from northern Qatar. Although it cannot be confirmed, it is expected that this contamination is mainly due to releases from the Chernobyl accident of 26 April 1986, there being a lack of data from Qatar before the accident. The values are typically within but are sometimes lower than the range indicated by data from other countries in the region. The lower values than those of others is suggested to be due to variation in soil characteristics as well as metrological factors at the time of deposition. - Highlights: • A baseline for the radionuclide 137 Cs in soil samples collected from Qatar was established. • 129 soil samples collected across the landscape. • Samples were collected before the most recent accident “the 2011 Fukushima Dai-ichi NNP accident”. • The highest activity concentration was found to be 15.41±0.67 Stat. and 0.11 Syst. • The relatively high concentrations can be attributed to rain washout.

  17. Practical application of in silico fragmentation based residue screening with ion mobility high-resolution mass spectrometry.

    Science.gov (United States)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathry; Walker, Stephan; Widmer, Mirjam

    2017-07-15

    A screening concept for residues in complex matrices based on liquid chromatography coupled to ion mobility high-resolution mass spectrometry LC/IMS-HRMS is presented. The comprehensive four-dimensional data (chromatographic retention time, drift time, mass-to-charge and ion abundance) obtained in data-independent acquisition (DIA) mode was used for data mining. An in silico fragmenter utilizing a molecular structure database was used for suspect screening, instead of targeted screening with reference substances. The utilized data-independent acquisition mode relies on the MS E concept; where two constantly alternating HRMS scans (low and high fragmentation energy) are acquired. Peak deconvolution and drift time alignment of ions from the low (precursor ion) and high (product ion) energy scan result in relatively clean product ion spectra. A bond dissociation in silico fragmenter (MassFragment) supplied with mol files of compounds of interest was used to explain the observed product ions of each extracted candidate component (chromatographic peak). Two complex matrices (fish and bovine liver extract) were fortified with 98 veterinary drugs. Out of 98 screened compounds 94 could be detected with the in silico based screening approach. The high correlation among drift time and m/z value of equally charged ions was utilized for an orthogonal filtration (ranking). Such an orthogonal ion mobility based filter removes multiply charged ions (e.g. peptides and proteins from the matrix) as well as noise and artefacts. Most significantly, this filtration dramatically reduces false positive findings but hardly increases false negative findings. The proposed screening approach may offer new possibilities for applications where reference compounds are hardly or not at all commercially available. Such areas may be the analysis of metabolites of drugs, pyrrolizidine alkaloids, marine toxins, derivatives of sildenafil or novel designer drugs (new psychoactive substances

  18. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    Science.gov (United States)

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  19. Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Dravecz, Gabriella; Bencs, László; Beke, Dávid; Gali, Adam

    2016-01-15

    The determination of Al contaminant and the main component Si in silicon carbide (SiC) nanocrystals with the size-distribution of 1-8nm dispersed in an aqueous solution was developed using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS). The vaporization/atomization processes were investigated in a transversally heated graphite atomizer by evaporating solution samples of Al and Si preserved in various media (HCl, HNO3). For Si, the best results were obtained by applying a mixture of 5µg Pd plus 5µg Mg, whereas for Al, 10µg Mg (each as nitrate solution) was dispensed with the samples, but the results obtained without modifier were found to be better. This way a maximum pyrolysis temperature of 1200°C for Si and 1300°C for Al could be used, and the optimum (compromise) atomization temperature was 2400°C for both analytes. The Si and Al contents of different sized SiC nanocrystals, dispersed in aqueous solutions, were determined against aqueous (external) calibration standards. The correlation coefficients (R values) of the calibrations were found to be 0.9963 for Si and 0.9991 for Al. The upper limit of the linear calibration range was 2mg/l Si and 0.25mg/l Al. The limit of detection was 3µg/l for Si and 0.5µg/l for Al. The characteristic mass (m0) was calculated to be 389pg Si and 6.4pg Al. The Si and Al content in the solution samples were found to be in the range of 1.0-1.7mg/l and 0.1-0.25mg/l, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Fragmentation analysis of water-soluble atmospheric organic matter using ultrahigh-resolution FT-ICR mass spectrometry.

    Science.gov (United States)

    Leclair, Jeffrey P; Collett, Jeffrey L; Mazzoleni, Lynn R

    2012-04-17

    Isolated water-soluble atmospheric organic matter (AOM) analytes extracted from radiation fogwater samples were analyzed using collision induced dissociation with ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Tandem mass analysis was performed on several mass ranges between 100 and 400 Da to characterize the functional groups of AOM species. Compounds containing nitrogen and/or sulfur were targeted because of the high number of oxygen atoms contained in their molecular formulas. Due to the large number of isobaric ions in the precursor isolation ranges, large numbers of product ions resulted from collision induced dissociation. Common neutral losses were assigned by matching the molecular formulas of the expected product ions with the detected product ions within the appropriate mass spectra. Since polar functional groups are expected to affect the hygroscopic properties of aerosols, the losses of H(2)O, CO(2), CH(3)OH, HNO(3), CH(3)NO(3), SO(3), SO(4) and combinations of these were specifically targeted. Among the 421 compounds studied, the most frequently observed neutral losses were CO(2) (54%), H(2)O (43%) and CH(3)OH (40%). HNO(3) losses were observed for 63% of the studied nitrogen containing compounds and 33% of the studied compounds containing both nitrogen and sulfur. SO(3) losses were observed for 85% of the studied sulfur containing compounds and 42% of studied compounds containing both nitrogen and sulfur. A number of molecular formulas matching those of monoterpene ozonolysis SOA were observed; they include organonitrates, organosulfates, and nitroxy-organosulfates. Overall, the results of fragmentation analysis of 400+ individual molecular precursors elucidate the complexity and multifunctional nature of the isolated water-soluble AOM.

  1. Development of a methodology for the detection of Ra226 in large volumes of water by gamma spectrometry; modification and validation of the method for detection and quantification of Ra226 in small volumes of water by alpha spectrometry, used by the Centro de Investigacion en Ciencias Atomicas, Nucleares y Moleculares (CICANUM, UCR)

    International Nuclear Information System (INIS)

    Molina Porras, Arnold

    2011-01-01

    The test method has been validated for quantifying the specific activity of Ra 226 in water alpha spectrometry. The CICANUM has used this method as part of the proposed harmonization of methods ARCAL (IAEA). The method is based on a first separation and preconcentration of Ra 226 by coprecipitation and subsequent MnO 2 micro precipitation as Ba (Ra) SO 4 . Samples were prepared and then was performed the counting by alpha spectrometry. A methodology of radio sampling for large volumes of water was tested in parallel, using acrylic fibers impregnated with manganese oxide (IV) to determine the amount of Ra 226 present by gamma spectrometry. Small-scale tests, have determined that the best way to prepare the fiber is the reference method found in the literature and using the oven at 60 degrees Celsius. (author) [es

  2. Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data.

    Science.gov (United States)

    Jaitly, Navdeep; Mayampurath, Anoop; Littlefield, Kyle; Adkins, Joshua N; Anderson, Gordon A; Smith, Richard D

    2009-03-17

    Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the

  3. Decon2LS: An open-source software package for automated processing and visualization of high resolution mass spectrometry data

    Directory of Open Access Journals (Sweden)

    Anderson Gordon A

    2009-03-01

    Full Text Available Abstract Background Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. Results With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to

  4. High-Resolution Mass Spectrometry and Molecular Characterization of Aqueous Photochemistry Products of Common Types of Secondary Organic Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Romonosky, Dian E.; Laskin, Alexander; Laskin, Julia; Nizkorodov, Sergey

    2015-03-19

    A significant fraction of atmospheric organic compounds is predominantly found in condensed phases, such as aerosol particles and cloud droplets. Many of these compounds are photolabile and can degrade through direct photolysis or indirect photooxidation processes on time scales that are comparable to the typical lifetimes of aqueous droplets (hours) and particles (days). This paper presents a systematic investigation of the molecular level composition and the extent of aqueous photochemical processing in different types of secondary organic aerosol (SOA) from biogenic and anthropogenic precursors including α-pinene, β-pinene, β-myrcene, d- limonene, α-humulene, 1,3,5-trimethylbenzene, and guaiacol, oxidized by ozone (to simulate a remote atmosphere) or by OH in the presence of NOx (to simulate an urban atmosphere). Chamber- and flow tube-generated SOA samples were collected, extracted in a methanol/water solution, and photolyzed for 1 h under identical irradiation conditions. In these experiments, the irradiation was equivalent to about 3-8 h of exposure to the sun in its zenith. The molecular level composition of the dissolved SOA was probed before and after photolysis with direct-infusion electrospray ionization high-resolution mass spectrometry (ESI-HR-MS). The mass spectra of unphotolyzed SOA generated by ozone oxidation of monoterpenes showed qualitatively similar features, and contained largely overlapping subsets of identified compounds. The mass spectra of OH/NOx generated SOA had more unique visual appearance, and indicated a lower extent of products overlap. Furthermore, the fraction of nitrogen containing species (organonitrates and nitroaromatics) was highly sensitive to the SOA precursor. These observations suggest that attribution of high-resolution mass spectra in field SOA samples to specific SOA precursors should be more straightforward under OH/NOx oxidation conditions compared to the ozone driven oxidation. Comparison of the SOA constituents

  5. Targeting high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance analysis with high-resolution radical scavenging profiles - bioactive secondary metabolites from the endophytic fungus Penicillium namyslowskii

    DEFF Research Database (Denmark)

    Wubshet, Sileshi Gizachew; Nyberg, Nils; Tejesvi, Mysore V.

    2013-01-01

    The high-resolution radical scavenging profile of an extract of the endophytic fungus Penicillium namyslowskii was used to target analysis by high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance spectroscopy, i.e., HPLC...... NMR probe designed for 1.7-mm NMR tubes. To further explore the potential of the above HPLC-HRMS-SPE-NMR platform for analysis of endophytic extracts, six peaks displaying no radical scavenging activity were also analyzed. This allowed unambiguous identification of six metabolites, i...... and griseofulvin, directly from crude extract via HPLC-HRMS-SPE-NMR. Dechlorodehydrogriseofulvin was reported for the first time from nature....

  6. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Science.gov (United States)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L- 1 and 0.054 μg L- 1 with the relative standard deviations (RSDs, n = 7, c = 5 μg L- 1) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2-50 μg L- 1. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications.

  7. Upconversion nanoparticle as elemental tag for the determination of alpha-fetoprotein in human serum by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Liu, Zhengru; Yang, Bin; Chen, Beibei; He, Man; Hu, Bin

    2016-12-19

    Upconversion nanoparticles (UCNPs) have received increasing attention due to their unique optical properties. Recognizing that UCNPs are lanthanide-doped nanoparticles, we incorporated UCNPs into an immunoassay with inductively coupled plasma mass spectrometry (ICP-MS) detection for the determination of specific proteins, e.g., alpha-fetoprotein (AFP). The sensitivity of the assay was enhanced because of the ICP-MS detection of UCNPs that contained large numbers of lanthanide elemental tags. Conjugates of UCNPs and antibodies were prepared and the morphology of the conjugates was characterized by transmission electron microscopy. After a sandwich immunoreaction, the AFP was determined by the ICP-MS analysis of UCNPs. Under the optimized conditions, a limit of detection (3σ) of 0.31 ng mL -1 based on 89 Y signal and 0.22 ng mL -1 based on 174 Yb signal was obtained for AFP, with a dynamic range of 0.5-35 ng mL -1 and a relative standard deviation of 4.8% (c = 5 ng mL -1 , n = 9). The developed method was applied to the determination of AFP in human serum and the recovery for the spiked sample was in the range of 98.6-123%. The proposed method is simple, rapid, selective and sensitive, and has a good tolerance for the complex biological matrix, indicating great potential for the application of UCNP in biological research as an elemental tag.

  8. Measurement of radon concentration in water by means of {alpha}, {gamma} spectrometry. Radon concentration in ground and spring water in Hiroshima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi [Hiroshima Univ. (Japan)

    1997-02-01

    Radon ({sup 222}Rn, T{sub 1/2}=3.8235{+-}0.0003d) is {alpha}-ray releasing nuclide, so that it can not be detected by {gamma}-ray measurement. But, the daughter nuclides {sup 214}Pb (T{sub 1/2}=26.8 min) and {sup 214}Bi (T{sub 1/2}=19.9 min) release {gamma}-ray, accordingly they are measured by Ge detector. Their radioactive equilibrium is kept in the closed vessel, because their half-lives are shorter than that of radon. We developed a measurement method of radon concentration by means of {gamma}-spectrometry. We applied this method to catch radon in the atmosphere by active carbon. The same principle can be applied to radon in water. Radon concentrations in the ground water were measured in 22 points in the Higashi-Hiroshima city and 82 points in the Hiroshima prefecture. The efficiencies of {gamma}-ray were determined. The radon concentration showed between 11 and 459 Bq/l and the average was 123 Bq/l. The high concentration of radon was distributed in the spring of granitic layer and higher concentration of radon were observed in the ground water of fault. (S.Y.)

  9. Plutonium determination in urine by techniques of mass spectrometry

    International Nuclear Information System (INIS)

    Hernandez M, H.; Yllera de Ll, A.

    2013-10-01

    The objective of this study was to develop an analytic method for quantification and plutonium reappraisal in plane tables of alpha spectrometry be means of the mass spectrometry technique of high resolution with plasma source inductively coupled and desolvator Aridus (Aridus-Hr-Icp-Ms) and mass spectrometry with accelerator (AMS). The obtained results were, the recovery percentage of Pu in the plane table was of ∼ 90% and activity minimum detectable obtained with Aridus-Hr-Icp-Ms and AMS was of ∼ 3 and ∼ 0.4 f g of 239 Pu, respectively. Conclusion, the results demonstrate the aptitude of the Aridus-Hr-Icp-Ms and AMS techniques in the Pu reappraisal in plane tables with bigger speed and precision, improving the values notably of the activity minimum detectable that can be obtained with the alpha spectrometry (∼ 50 f g of 239 Pu). (author)

  10. Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment

    International Nuclear Information System (INIS)

    Ribeiro, Anderson Schwingel; Vieira, Mariana Antunes; Furtado da Silva, Alessandra; Borges, Daniel L. Gallindo; Welz, Bernhard; Heitmann, Uwe; Curtius, Adilson Jose

    2005-01-01

    Two procedures for the determination of Co in biological samples by graphite furnace atomic absorption spectrometry (GF AAS) were compared: solid sampling (SS) and alkaline treatment with tetramethylammonium hydroxide (TMAH) using two different instruments for the investigation: a conventional line-source (LS) atomic absorption spectrometer and a prototype high-resolution continuum source atomic absorption spectrometer. For the direct introduction of the solid samples, certified reference materials (CRM) were ground to a particle size ≤50 μm. Alkaline treatment was carried out by placing about 250 mg of the sample in polypropylene flasks, adding 2 mL of 25% m/v tetramethylammonium hydroxide and de-ionized water. Due to its unique capacity of providing a 3-D spectral plot, a high-resolution continuum source (HR-CS) graphite furnace atomic absorption spectrometry was used as a tool to evaluate potential spectral interferences, including background absorption for both sample introduction procedures, revealing that a continuous background preceded the atomic signal for pyrolysis temperatures lower than 700 deg. C. Molecular absorption bands with pronounced rotational fine structure appeared for atomization temperatures >1800 deg. C probably as a consequence of the formation of PO. After optimization had been carried out using high resolution continuum source atomic absorption spectrometry, the optimized conditions were adopted also for line-source atomic absorption spectrometry. Six biological certified reference materials were analyzed, with calibration against aqueous standards, resulting in agreement with the certified values (according to the t-test for a 95% confidence level) and in detection limits as low as 5 ng g -1

  11. Triple Quadrupole Versus High Resolution Quadrupole-Time-of-Flight Mass Spectrometry for Quantitative LC-MS/MS Analysis of 25-Hydroxyvitamin D in Human Serum

    Science.gov (United States)

    Geib, Timon; Sleno, Lekha; Hall, Rabea A.; Stokes, Caroline S.; Volmer, Dietrich A.

    2016-08-01

    We describe a systematic comparison of high and low resolution LC-MS/MS assays for quantification of 25-hydroxyvitamin D3 in human serum. Identical sample preparation, chromatography separations, electrospray ionization sources, precursor ion selection, and ion activation were used; the two assays differed only in the implemented final mass analyzer stage; viz. high resolution quadrupole-quadrupole-time-of-flight (QqTOF) versus low resolution triple quadrupole instruments. The results were assessed against measured concentration levels from a routine clinical chemiluminescence immunoassay. Isobaric interferences prevented the simple use of TOF-MS spectra for extraction of accurate masses and necessitated the application of collision-induced dissociation on the QqTOF platform. The two mass spectrometry assays provided very similar analytical figures of merit, reflecting the lack of relevant isobaric interferences in the MS/MS domain, and were successfully applied to determine the levels of 25-hydroxyvitamin D for patients with chronic liver disease.

  12. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Science.gov (United States)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6-4.3%), repeatability (4-9%), reproducibility (9-11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as straightforward

  13. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia, E-mail: e.vasileva-veleva@iaea.org

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6–4.3%), repeatability (4–9%), reproducibility (9–11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as

  14. Molecular composition of rainwater and aerosol during rain events in León, Spain, using high resolution mass spectrometry.

    Science.gov (United States)

    Fee, Anna

    2017-04-01

    Anna Fee (1), Markus Kalberer (1), Roberto Fraile (2), Amaya Castro (2), Ana. I. Calvo (2), Carlos Blanco-Alegre (2), Fernanda Oduber (2) and Mário Cerqueira (3). 1 Department of Chemistry, University of Cambridge, UK. 2 Department of Applied Chemistry and Physics, IMARENAB, University of León, Spain. 3 Department of Environmental Planning, University of Aveiro, Portugal. A wide range of atmospheric compounds which are present in rainwater are often also present in aerosol. They can be taken up during cloud droplet formation (in-cloud scavenging) or washed out during precipitation (below-cloud scavenging). Such compounds including aromatic hydrocarbons and organic nitrogen containing compounds are hazardous to health. In this study, the organic chemical composition of rainwater and aerosol from rain events in León, Spain, is being analysed using high resolution mass spectrometry. Collected rainwater along with high volume and low volume filters from rain events which occurred during spring, summer and winter of 2016 have been selected for analysis. Rainwater samples were prepared using Polymeric Reversed Phase Solid Phase Extraction (SPE) and filters have been extracted in water with and without SPE. Three different SPE polymer based sorbents were tested; one for extracting neutral compounds and two which are more suitable for extracting organic compounds containing sulphate and other polar functional groups. The sorbent for extracting neutral compounds was found to yield a higher number of compounds from the sample extraction than the other two varieties. Kendrick masses, Van Krevelen plots and carbon oxidation states have been investigated to identify compounds and patterns. Preliminary results show a predominance in peaks with O/C ratios between 0.2 and 0.7 and H/C ratios between 1 and 2 in both rain and aerosol samples which indicates substituted aromatic compounds. Cellulose material and fatty acids may also be present. The rain samples also have a

  15. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mol, Hans G.J., E-mail: hans.mol@wur.nl; Tienstra, Marc; Zomer, Paul

    2016-09-07

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg{sup −1}) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg{sup −1}. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive

  16. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    International Nuclear Information System (INIS)

    Mol, Hans G.J.; Tienstra, Marc; Zomer, Paul

    2016-01-01

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg"−"1) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg"−"1. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive alternative to

  17. High-resolution continuum source electrothermal atomic absorption spectrometry: Linearization of the calibration curves within a broad concentration range

    Energy Technology Data Exchange (ETDEWEB)

    Katskov, Dmitri, E-mail: katskovda@tut.ac.za [Tshwane University of Technology, Chemistry Department, Pretoria 0001 (South Africa); Hlongwane, Miranda [Tshwane University of Technology, Chemistry Department, Pretoria 0001 (South Africa); Heitmann, Uwe [German Aerospace Center, Rose-Luxemburg Str. 2, 10178 Berlin (Germany); Florek, Stefan [ISAS-Leibniz-Institut fuer Analytische Wissenschaften e.V., Albert-Einstein-Str. 9,12489 Berlin (Germany)

    2012-05-15

    The calculation algorithm suggested provides linearization of the calibration curves in high-resolution continuum source electrothermal atomic absorption spectrometry. The algorithm is based on the modification of the function wavelength-integrated absorbance vs. concentration of analyte vapor in the absorption volume. According to the suggested approach, the absorption line is represented by a triangle for low and trapezium for high analyte vapor concentration in the absorption volume. The respective semi-empirical formulas include two linearization parameters, which depend on properties of the absorption line and characteristics of the atomizer and spectrometer. The parameters can be approximately evaluated from the theory and determined in practice from the original broad-range calibration curve. The parameters were found and the proposed calculation algorithm verified in the experiments on direct determination of Ag, Cd, Cu, Fe, Mn and Pb in the solutions within a concentration ranges from 0.15 to 625 {mu}g{center_dot}L{sup -1} using tube, platform tube and filter furnace atomizers. The use of various atomizers, lines, elements and atomization temperatures made possible the simulation of various practical analytical conditions. It was found that the algorithm and optimal linearization parameters made it possible to obtain for each line and atomizer linear approximations of the calibration curves within 3-4 orders of magnitude with correlation coefficients close to 0.999. The algorithm makes possible to employ a single line for the direct element determination over a broad concentration range. The sources of errors and the possibility of a priori theoretical evaluation of the linearization parameters are discussed. - Highlights: Black-Right-Pointing-Pointer New calculation algorithm for HR-CS ET AAS measurements was proposed and applied. Black-Right-Pointing-Pointer The suggested formulas include two parameters to be determined experimentally. Black

  18. Molecular characterization of water soluble organic nitrogen in marine rainwater by ultra-high resolution electrospray ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    K. E. Altieri

    2012-04-01

    Full Text Available Atmospheric water soluble organic nitrogen (WSON is a subset of the complex organic matter in aerosols and rainwater, which impacts cloud condensation processes and aerosol chemical and optical properties and may play a significant role in the biogeochemical cycle of N. However, its sources, composition, connections to inorganic N, and variability are largely unknown. Rainwater samples were collected on the island of Bermuda (32.27° N, 64.87° W, which experiences both anthropogenic and marine influenced air masses. Samples were analyzed by ultra-high resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry to chemically characterize the WSON. Elemental compositions of 2281 N containing compounds were determined over the mass range m/z+ 50 to 500. The five compound classes with the largest number of elemental formulas identified, in order from the highest number of formulas to the lowest, contained carbon, hydrogen, oxygen, and nitrogen (CHON+, CHON compounds that contained sulfur (CHONS+, CHON compounds that contained phosphorus (CHONP+, CHON compounds that contained both sulfur and phosphorus (CHONSP+, and compounds that contained only carbon, hydrogen, and nitrogen (CHN+. Compared to rainwater collected in the continental USA, average O:C ratios of all N containing compound classes were lower in the marine samples whereas double bond equivalent values were higher, suggesting a reduced role of secondary formation mechanisms. Despite their prevalence in continental rainwater, no organonitrates or nitrooxy-organosulfates were detected, but there was an increased presence of organic S and organic P containing compounds in the marine rainwater. Cluster analysis showed a clear chemical distinction between samples collected during the cold season (October to March which have anthropogenic air mass origins and samples collected during the warm season (April to September with remote

  19. Radiochemical data obtained by {alpha} spectrometry on unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea

    Energy Technology Data Exchange (ETDEWEB)

    Choukri, A. [Laboratoire de Physique de la Matiere et Rayonnement, Equipe de Physique et Techniques Nucleaires, UFR ' Faibles Radioactivites, Mathematiques physiques et environnement' Universite Ibn Tofail, Faculte des Sciences, Departement de Physique, P.B. 133, 14 000 Kenitra (Morocco)]. E-mail: choukrimajid@yahoo.com; Hakam, O.K. [Laboratoire de Physique de la Matiere et Rayonnement, Equipe de Physique et Techniques Nucleaires, UFR ' Faibles Radioactivites, Mathematiques physiques et environnement' Universite Ibn Tofail, Faculte des Sciences, Departement de Physique, P.B. 133, 14 000 Kenitra (Morocco); Reyss, J.L. [Laboratoire des Sciences de Climat et de l' Environnement, Domaine du CNRS, Avenue de la Terrasse 91 1958, Gif sur Yvette (France); Plaziat, J.C. [Universite de Paris-Sud, Departement des Sciences de la Terre, URA 723, Batiment 504, F-91405 Orsay, Cedex (France)

    2007-02-15

    In this work, radiochemical results obtained by {alpha} spectrometry on 80 unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea are presented and discussed. The coral samples were collected in Egypt from the emerged 5e coral reef terraces over 500km from The Ras Gharib-Ras Shukeir depression (28 deg. 10{sup '}) in the north to Wadi Lahami (north of Ras Banas, 24 deg. 10{sup '}) in the south. The statistical description of radiochemical results (concentrations of U and Th radioisotopes, {sup 234}U/{sup 238}U activity ratios and ages) obtained on a great number of coral samples showed that it is possible to establish methodological criterions which could be used to validate the measured ages before confronting them to the geological context of sampling sites. The obtained results confirm that the unrecrystallized corals ({sup 232}Th<3%) constitute the reliable means of determining the timing of Pleistocene sea-level fluctuations in the past. A few number of measured younger ages could be explain as a result of a rejuvenation due to latter addition of a ''younger'' uranium to the initial stock entered just after coral death. The obvious rejuvenation observed and confirmed is due to a recent cementation of aragonitic deposit on the fossil coral. {sup 238}U varies between 2.2 and 4.9ppm around an average of 3.18+/-0.65ppm. {sup 234}U/ {sup 238}U activity ratios are between 1.08 and 1.28 with an averaged value of 1.164+/-0.016 which exceeds that of present day sea water but which is in agreement with the ratio of 1.16 measured by a precise mass spectrometry in many Pleistocene coral samples. Except three samples dated at least 100ka, the radiochemical age of 5e coral samples vary between 108 and 131ka with an average value of 122.2ka and a standard deviation of 4.3ka. Except for samples from the Zeit area, the reef terrace is between 2 and 6m above the present sea level. This position is similar to

  20. Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Nakadi, Flávio V; Prodanov, Caroline; Boschetti, Wiliam; Vale, Maria Goreti R; Welz, Bernhard; de Andrade, Jailson B

    2018-03-01

    Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (λ = 251.611nm, 1 detection pixel, N 2 O/C 2 H 2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO 3 and HF. HR-CS GF AAS (T pyr = 1400°C, T atom = 2650°C) has evaluated Si in pyrolysis water and bio-oil at 251.611nm, and in peach pit biomass and ash at 221.174nm using SS, both wavelengths with 1 detection pixel. Rhodium (300μg) was applied as permanent modifier and 10μgPd + 6μg Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20mgkg -1 , and LOQ 0.3-20mgkg -1 , considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% mm -1 , 1.1-1.7mgkg -1 , 3.3-13mgkg -1 , and 0.41-1.4%mm -1 , in biomass, bio-oil, pyrolysis water and ash, respectively

  1. Determination of gold and cobalt dopants in advanced materials based on tin oxide by slurry sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Filatova, Daria G.; Eskina, Vasilina V.; Baranovskaya, Vasilisa B.; Vladimirova, Svetlana A.; Gaskov, Alexander M.; Rumyantseva, Marina N.; Karpov, Yuri A.

    2018-02-01

    A novel approach is developed for the determination of Co and Au dopants in advanced materials based on tin oxide using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with direct slurry sampling. Sodium carboxylmethylcellulose (Na-CMC) is an effective stabilizer for diluted suspensions. Use Na-CMC allows to transfer the analytes into graphite furnace completely and reproducibly. The relative standard deviation obtained by HR CS GFAAS was not higher than 4%. Accuracy was proven by means inductively coupled plasma mass spectrometry (ICP-MS) in solutions after decomposition as a comparative technique. To determine Au and Co in the volume of SnO2, the acid decomposition conditions (HCl, HF) of the samples were suggested by means of an autoclave in a microwave oven.

  2. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin, E-mail: binhu@whu.edu.cn

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L{sup −1} and 0.054 μg L{sup −1} with the relative standard deviations (RSDs, n = 7, c = 5 μg L{sup −1}) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2–50 μg L{sup −1}. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications. - Highlights: • 4-Mercaptophenylboronic acid functionalized magnetic beads were prepared and characterized. • ICP-MS based magnetic immunoassay approach was developed for quantification of glycoproteins. • AFP and CEA were quantified simultaneously with Au and Ag NPs as element tags. • The developed method exhibited good selectivity and sensitivity for target glycoproteins.

  3. Description of analytical method and clinical utility of measuring serum 7-alpha-hydroxy-4-cholesten-3-one (7aC4) by mass spectrometry.

    Science.gov (United States)

    Donato, Leslie J; Lueke, Alan; Kenyon, Stacy M; Meeusen, Jeffrey W; Camilleri, Michael

    2018-02-01

    Imbalance of bile acids (BA) homeostasis in the gastrointestinal tract can lead to chronic diarrhea or constipation when BA in the colon are in excess or low, respectively. Since both disturbances of bowel function can result from other etiologies, identifying BA imbalance is important to tailor treatment strategies. Serum concentrations of 7-alpha-hydroxy-4-cholesten-3-one (7aC4), a precursor in bile acid synthesis, reflect BA homeostasis. Here we describe a method to accurately measure serum 7aC4 and evaluate the clinical utility in patients with diarrhea or constipation phenotypes. Serum 7aC4 is measured after acetonitrile protein precipitation using C18 liquid chromatography, tandem mass spectrometry, and deuterium-labeled 7aC4 internal standard. Assay performance including linearity, precision, and accuracy was assessed using waste serum samples. The reference interval was established in healthy individuals without BA-altering conditions or medications. Clinical performance was assessed in patients with irritable bowel syndrome. The method precisely and accurately measured 7aC4 in human serum from 1.4-338ng/mL with no ion suppression or interference from related 7-keto-cholesterol. Central 95th percentile reference interval was 2.5-63.2ng/mL. Lower serum 7aC4 was found in patients with constipation with sensitivity/specificity of 79%/55% compared to healthy controls. Higher 7aC4 was found in patients with bile acid diarrhea (BAD) compared to those without BAD with sensitivity/specificity of 82%/53%. We have developed a sensitive and precise assay for measuring the concentration of 7aC4 in serum. The assay can be used to screen for diarrhea caused by bile acid malabsorption. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Characterization of the designer drug deschloroketamine (2-methylamino-2-phenylcyclohexanone) by gas chromatography/mass spectrometry, liquid chromatography/high-resolution mass spectrometry, multistage mass spectrometry, and nuclear magnetic resonance.

    Science.gov (United States)

    Frison, Giampietro; Zamengo, Luca; Zancanaro, Flavio; Tisato, Francesco; Traldi, Pietro

    2016-01-15

    Clinical and forensic toxicology laboratories are challenged every day by the analytical aspects of the new psychoactive substances phenomenon. In this study we describe the analytical characterization of a new ketamine derivative, deschloroketamine (2-methylamino-2-phenylcyclohexanone), contained in seized powders. The analytical techniques employed include gas chromatography/mass spectrometry (GC/MS), liquid chromatography/electrospray ionization coupled with Orbitrap high-resolution/MS (LC/ESI-HRMS), multistage MS (ESI-MS(n)), and NMR. The LC/ESI-HRMS analyses consisted of accurate mass measurements of MH(+) ions in full-scan mode; comparison of experimental and calculated MH(+) isotopic patterns; and examination of the isotopic fine structure (IFS) of the M + 1, M + 2, M + 3 isotopic peaks relative to the monoisotopic M + 0 peak. The collision-induced product ions of the MH(+) ions were studied by both HRMS and MS(n). (1)H and (13)C NMR measurements were carried out to confirm the chemical structure of the analyte. The EI mass spectra obtained by GC/MS analysis showed the presence of molecular ions at m/z 203, and main fragment ions at m/z 175, 174, 160, 147, 146, and 132. The application of LC/ESI-HRMS allowed us to obtain: the accurate mass of deschloroketamine MH(+) ions with a mass accuracy of 1.47 ppm; fully superimposable experimental and calculated MH(+) isotopic patterns, with a relative isotopic abundance value of 3.69 %; and the IFS of the M + 1, M + 2, M + 3 isotopic peaks completely in accordance with theoretical values. Examination of the product ions of MH(+), as well as the study of both (1)H and (13)C NMR spectra, enabled the full characterization of the molecular structure of deschloroketamine. The combination of the employed analytical techniques allowed the characterization of the seized psychoactive substance, in spite of the lack of a reference standard. Deschloroketamine is a ketamine analogue considered to be

  5. Novel strategy for the determination of illegal adulterants in health foods and herbal medicines using high-performance liquid chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Wang, Zhe; Wu, Caisheng; Wang, Gangli; Zhang, Qingsheng; Zhang, Jinlan

    2015-03-01

    The detection, confirmation, and quantification of multiple illegal adulterants in health foods and herbal medicines by using a single analytical method are a challenge. This paper reports on a new strategy to meet this challenge by employing high-performance liquid chromatography coupled with high-resolution mass spectrometry and a mass spectral tree similarity filter technique. This analytical method can rapidly collect high-resolution, high-accuracy, optionally multistage mass data for compounds in samples. After a preliminary screening by retention time and high-resolution mass spectral data, known illegal adulterants can be detected. The mass spectral tree similarity filter technique has been applied to rapidly confirm these adulterants and simultaneously discover unknown ones. By using full-scan mass spectra as stem and data-dependent subsequent stage mass spectra to form branches, mass spectrometry data from detected compounds are converted into mass spectral trees. The known or unknown illegal adulterants in the samples are confirmed or discovered based on the similarity between their mass spectral trees and those of the references in a library, and they are finally quantified against standard curves. This new strategy has been tested by using 50 samples, and the illegal adulterants were rapidly and effectively detected, confirmed and quantified. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Identification of 4,5-didemethyl-4-O-alpha-D-glucopyranosylsimmondsin and pinitol alpha-D-galactosides in jojoba seed meal (Simmondsia chinensis).

    Science.gov (United States)

    Van Boven, M; Leyssen, T; Busson, R; Holser, R; Cokelaere, M; Flo, G; Decuypere, E

    2001-09-01

    The isolation and identification of two pinitol alpha-D-galactosides from jojoba meal are described. The products were isolated by a combination of preparative HPLC on silica gel and TLC on amino silica gel and were identified by MS, NMR spectroscopy, and chemical derivatization as 5-O-(alpha-D-galactopyranosyl)-3-O-methyl-D-chiro-inositol or 5-alpha-D-galactopyranosyl-D-pinitol and 2-O-(alpha-D-galactopyranosyl)-3-O-methyl-D-chiro-inositol or 2-alpha-D-galactopyranosyl-D-pinitol. The same preparative HPLC method on silica gel allowed a new simmondsin derivative to be isolated and identified as 4,5-didemethyl-4-O-alpha-D-glucopyranosylsimmondsin mainly by NMR spectroscopy and high-resolution mass spectrometry.

  7. Rapid non-destructive quantitative estimation of urania/ thoria in mixed thorium uranium di-oxide pellets by high-resolution gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shriwastwa, B.B.; Kumar, Anil; Raghunath, B.; Nair, M.R.; Abani, M.C.; Ramachandran, R.; Majumdar, S.; Ghosh, J.K

    2001-06-01

    A non-destructive technique using high-resolution gamma-ray spectrometry has been standardised for quantitative estimation of uranium/thorium in mixed (ThO{sub 2}-UO{sub 2}) fuel pellets of varying composition. Four gamma energies were selected; two each from the uranium and thorium series and the time of counting has been optimised. This technique can be used for rapid estimation of U/Th percentage in a large number of mixed fuel pellets from a production campaign.

  8. Determination of sulfur in bovine serum albumin and L-cysteine using high-resolution continuum source molecular absorption spectrometry of the CS molecule

    Science.gov (United States)

    Andrade-Carpente, Eva; Peña-Vázquez, Elena; Bermejo-Barrera, Pilar

    2016-08-01

    In this study, the content of sulfur in bovine serum albumin and L-cysteine was determined using high-resolution continuum source molecular absorption spectrometry of the CS molecule, generated in a reducing air-acetylene flame. Flame conditions (height above the burner, measurement time) were optimized using a 3.0% (v/v) sulfuric acid solution. A microwave lab station (Ethos Plus MW) was used for the digestion of both compounds. During the digestion step, sulfur was converted to sulfate previous to the determination. Good repeatability (4-10%) and analytical recovery (91-106%) was obtained.

  9. Prediction of collision cross section and retention time for broad scope screening in gradient reversed-phase liquid chromatography-ion mobility-high resolution accurate mass spectrometry

    DEFF Research Database (Denmark)

    Mollerup, Christian Brinch; Mardal, Marie; Dalsgaard, Petur Weihe

    2018-01-01

    artificial neural networks (ANNs). Prediction was based on molecular descriptors, 827 RTs, and 357 CCS values from pharmaceuticals, drugs of abuse, and their metabolites. ANN models for the prediction of RT or CCS separately were examined, and the potential to predict both from a single model......Exact mass, retention time (RT), and collision cross section (CCS) are used as identification parameters in liquid chromatography coupled to ion mobility high resolution accurate mass spectrometry (LC-IM-HRMS). Targeted screening analyses are now more flexible and can be expanded for suspect...

  10. Effect of prior dust collection on detection, counting efficiency, and energy resolution for alpha continuous air monitors

    International Nuclear Information System (INIS)

    Newton, G.J.; Hoover, M.D.

    1994-01-01

    For the past several years, we have supported the DOE Waste Isolation Pilot Plant (WIPP) project by evaluating the capabilities and performance of the Eberline Alpha 6 continuous air monitor (CAM). This evalution has focused on the ability of the CAM to correctly report plutonium in the presence of salt dust. Tests involving the simultaneous collection of plutonium and salt have shown that burial by salt can degrade the detection of plutonium, but that this interference is negligible when salt concentrations are below about 0.2 mg/m 3 . Throughout the evalution, it has been assumed that salt burial is a concern for slow, chronic release of plutonium, but that any acute release of plutonium would be collected on the top surface of the filter or salt and would be unattenuated. The spectral quality of alpha radiation detection on membrane filters is observed to improve with filter loading. This is attributed to the probability that accumulations of dust tend to fill in surface irregularities of the collection filter at a a faster rate than they create additional surface irregularities. The validity of these assumptions about the improved detection of plutonium on salt-layer surfaces has recently been questioned. Based on electron micrographic examination of salt-laden filters, it has been speculated that collection of salt dust on a membrane filter results in formation of pores, fissures, and dendritic shapes of salt on the filter surface. If plutonium were collected, particles could penetrate into the pores and fissures, resulting in a degraded or lost signal from the plutonium. Because no experimental evidence existed to answer the concern, the purpose of the current study was to quantify any differences between detection of plutonium on clean or salt-laden filters

  11. Elucidation and identification of amino acid containing membrane lipids using liquid chromatography/high-resolution mass spectrometry

    NARCIS (Netherlands)

    Moore, E.K.; Hopmans, E.C.; Rijpstra, W.I.C.; Villanueva, L.; Sinninghe Damsté, J.S.

    2016-01-01

    RATIONALE: Intact polar lipids (IPLs) are the building blocks of cell membranes, and amino acid containing IPLs havebeen observed to be involved in response to changing environmental conditions in various species of bacteri a. High-performance liquid chromatography/mass spectrometry (HPLC/MS) has

  12. Desorption atmospheric pressure photoionization high-resolution mass spectrometry: a complementary approach for the chemical analysis of atmospheric aerosols

    Czech Academy of Sciences Publication Activity Database

    Parshintsev, J.; Vaikkinen, A.; Lipponen, K.; Vrkoslav, Vladimír; Cvačka, Josef; Kostiainen, R.; Kotiaho, T.; Hartonen, K.; Riekkola, M. L.; Kauppila, T. J.

    2015-01-01

    Roč. 29, č. 13 (2015), s. 1233-1241 ISSN 0951-4198 Grant - others:GA AV ČR(CZ) M200551204 Institutional support: RVO:61388963 Keywords : atmospheric aerosols * mass spectrometry * ambient ionization Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.226, year: 2015

  13. Curve resolution and figures of merit estimation for determination of trace elements in geological materials by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Lorber, A.; Harel, A.; Goldbart, Z.; Brenner, I.B.

    1987-01-01

    In geochemical analysis using inductively coupled plasma atomic emission spectrometry (ICP-AES), spectral interferences and background enhancement in response to sample concomitants are the main cause of deterioration of the limit of detection (LOD) and inaccuracy of the determination at the trace and minor element levels. In this account, the authors describe the chemometric procedure of curve resolution for compensating for these sources of error. A newly developed method for calculating figures of merit is used to evaluate the correction procedure, test the statistical significance of the determined concentration, and determine LODs for each sample. The technique involves scanning the vicinity of the spectral line of the analyte. With prior knowledge of potential spectral interferences, deconvolution of the overlapped response is possible. Analytical data for a wide range of geological standard reference materials demonstrate the effectiveness of the chemometric techniques. Separation of 0.002 nm spectral coincidence, employing a 0.02 nm resolution spectrometer, is demonstrated

  14. A Computational Drug Metabolite Detection Using the Stable Isotopic Mass-Shift Filtering with High Resolution Mass Spectrometry in Pioglitazone and Flurbiprofen

    Directory of Open Access Journals (Sweden)

    Yohei Miyamoto

    2013-09-01

    Full Text Available The identification of metabolites in drug discovery is important. At present, radioisotopes and mass spectrometry are both widely used. However, rapid and comprehensive identification is still laborious and difficult. In this study, we developed new analytical software and employed a stable isotope as a tool to identify drug metabolites using mass spectrometry. A deuterium-labeled compound and non-labeled compound were both metabolized in human liver microsomes and analyzed by liquid chromatography/time-of-flight mass spectrometry (LC-TOF-MS. We computationally aligned two different MS data sets and filtered ions having a specific mass-shift equal to masses of labeled isotopes between those data using our own software. For pioglitazone and flurbiprofen, eight and four metabolites, respectively, were identified with calculations of mass and formulas and chemical structural fragmentation analysis. With high resolution MS, the approach became more accurate. The approach detected two unexpected metabolites in pioglitazone, i.e., the hydroxypropanamide form and the aldehyde hydrolysis form, which other approaches such as metabolite-biotransformation list matching and mass defect filtering could not detect. We demonstrated that the approach using computational alignment and stable isotopic mass-shift filtering has the ability to identify drug metabolites and is useful in drug discovery.

  15. Identification of ortho-Substituted Benzoic Acid/Ester Derivatives via the Gas-Phase Neighboring Group Participation Effect in (+)-ESI High Resolution Mass Spectrometry.

    Science.gov (United States)

    Blincoe, William D; Rodriguez-Granillo, Agustina; Saurí, Josep; Pierson, Nicholas A; Joyce, Leo A; Mangion, Ian; Sheng, Huaming

    2018-04-01

    Benzoic acid/ester/amide derivatives are common moieties in pharmaceutical compounds and present a challenge in positional isomer identification by traditional tandem mass spectrometric analysis. A method is presented for exploiting the gas-phase neighboring group participation (NGP) effect to differentiate ortho-substituted benzoic acid/ester derivatives with high resolution mass spectrometry (HRMS 1 ). Significant water/alcohol loss (>30% abundance in MS 1 spectra) was observed for ortho-substituted nucleophilic groups; these fragment peaks are not observable for the corresponding para and meta-substituted analogs. Experiments were also extended to the analysis of two intermediates in the synthesis of suvorexant (Belsomra) with additional analysis conducted with nuclear magnetic resonance (NMR), density functional theory (DFT), and ion mobility spectrometry-mass spectrometry (IMS-MS) studies. Significant water/alcohol loss was also observed for 1-substituted 1, 2, 3-triazoles but not for the isomeric 2-substituted 1, 2, 3-triazole analogs. IMS-MS, NMR, and DFT studies were conducted to show that the preferred orientation of the 2-substituted triazole rotamer was away from the electrophilic center of the reaction, whereas the 1-subtituted triazole was oriented in close proximity to the center. Abundance of NGP product was determined to be a product of three factors: (1) proton affinity of the nucleophilic group; (2) steric impact of the nucleophile; and (3) proximity of the nucleophile to carboxylic acid/ester functional groups. Graphical Abstract ᅟ.

  16. Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Dessuy, Morgana B.; Vale, Maria Goreti R.; Lepri, Fabio G.; Borges, Daniel L.G.; Welz, Bernhard; Silva, Marcia M.; Heitmann, Uwe

    2008-01-01

    The artifacts created in the measurement of phosphorus at the 213.6-nm non-resonance line by electrothermal atomic absorption spectrometry using line source atomic absorption spectrometry (LS AAS) and deuterium lamp background correction (D 2 BC) have been investigated using high-resolution continuum source atomic absorption spectrometry (HR-CS AAS). The absorbance signals and the analytical curves obtained by LS AAS without and with D 2 BC, and with HR-CS AAS without and with automatic correction for continuous background absorption, and also with least-squares background correction for molecular absorption with rotational fine structure were compared. The molecular absorption due to the suboxide PO that exhibits pronounced fine structure could not be corrected by the D 2 BC system, causing significant overcorrection. Among the investigated chemical modifiers, NaF, La, Pd and Pd + Ca, the Pd modifier resulted in the best agreement of the results obtained with LS AAS and HR-CS AAS. However, a 15% to 100% higher sensitivity, expressed as slope of the analytical curve, was obtained for LS AAS compared to HR-CS AAS, depending on the modifier. Although no final proof could be found, the most likely explanation is that this artifact is caused by a yet unidentified phosphorus species that causes a spectrally continuous absorption, which is corrected without problems by HR-CS AAS, but which is not recognized and corrected by the D 2 BC system of LS AAS

  17. [Uncertainty evaluation of the determination of toxic equivalent quantity of polychlorinated dibenzo-p-dioxins and dibenzofurans in soil by isotope dilution high resolution gas chromatography and high resolution mass spectrometry].

    Science.gov (United States)

    Du, Bing; Liu Aimin; Huang, Yeru

    2014-09-01

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil samples were analyzed by isotope dilution method with high resolution gas chromatography and high resolution mass spectrometry (ID-HRGC/HRMS), and the toxic equivalent quantity (TEQ) were calculated. The impacts of major source of measurement uncertainty are discussed, and the combined relative standard uncertainties were calculated for each 2, 3, 7, 8 substituted con- gener. Furthermore, the concentration, combined uncertainty and expanded uncertainty for TEQ of PCDD/Fs in a soil sample in I-TEF, WHO-1998-TEF and WHO-2005-TEF schemes are provided as an example. I-TEF, WHO-1998-TEF and WHO-2005-TEF are the evaluation schemes of toxic equivalent factor (TEF), and are all currently used to describe 2,3,7,8 sub- stituted relative potencies.

  18. Food contaminant analysis at ultra-high mass resolution: application of hybrid linear ion trap - orbitrap mass spectrometry for the determination of the polyether toxins, azaspiracids, in shellfish.

    LENUS (Irish Health Repository)

    2010-10-30

    The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high-resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra-high-resolution full-scan MS analysis and collision-induced dissociation (CID) tandem mass spectrometry (MS\\/MS). Using the highest mass resolution setting (100,000 FWHM) in full-scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra-high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1\\/AZA6 and AZA4\\/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full-scan FTMS. Using HCD MS\\/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m\\/z values throughout the mass spectral range and this enhanced the reliability of analyte identity.For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg\\/g using full-scan FTMS and this was comparable with the LOQ (0.007 µg\\/g) using CID MS\\/MS. The repeatability data were; intra-day RSD% (1.8-4.4%; n = 6) and inter-day RSD% (4.7-8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high-resolution full-scan Orbitrap MS and low-resolution CID MS\\/MS, produced

  19. Use of ultra-high pressure liquid chromatography coupled to high resolution mass spectrometry for fast screening in high throughput doping control.

    Science.gov (United States)

    Musenga, Alessandro; Cowan, David A

    2013-05-03

    We describe a sensitive, comprehensive and fast screening method based on liquid chromatography-high resolution mass spectrometry for the detection of a large number of analytes in sports samples. UHPLC coupled to high resolution mass spectrometry with polarity switching capability is applied for the rapid screening of a large number of analytes in human urine samples. Full scan data are acquired alternating both positive and negative ionisation. Collision-induced dissociation with positive ionisation is also performed to produce fragment ions to improve selectivity for some analytes. Data are reviewed as extracted ion chromatograms based on narrow mass/charge windows (±5ppm). A simple sample preparation method was developed, using direct enzymatic hydrolysis of glucuronide conjugates, followed by solid phase extraction with mixed mode ion-exchange cartridges. Within a 10min run time (including re-equilibration) the method presented allows for the analysis of a large number of analytes from most of the classes in the World Anti-Doping Agency (WADA) Prohibited List, including anabolic agents, β2-agonists, hormone antagonists and modulators, diuretics, stimulants, narcotics, glucocorticoids and β-blockers, and does so while meeting the WADA sensitivity requirements. The high throughput of the method and the fast sample pre-treatment reduces analysis cost and increases productivity. The method presented has been used for the analysis of over 5000 samples in about one month and proved to be reliable. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Comparison of laser fluorimetry, high resolution gamma-ray spectrometry and neutron activation analysis techniques for determination of uranium content in soil samples

    International Nuclear Information System (INIS)

    Ghods, A.; Asgharizadeh, F.; Salimi, B.; Abbasi, A.

    2004-01-01

    Much more concern is given nowadays for exposure of the world population to natural radiation especially to uranium since 57% of that exposure is due to radon-222, which is a member of uranium decay series. Most of the methods used for uranium determination is low concentration require either tedious separation and preconcentration or the accessibility to special instrumentation for detection of uranium at this low level. this study compares three techniques and methods for uranium analysis among different soil sample with variable uranium contents. Two of these techniques, neutron activation analysis and high resolution gamma-ray spectrometry , are non-destructive while the other, laser fluorimetry is done via chemical extraction of uranium. Analysis of standard materials is done also to control the quality and accuracy of the work. In spite of having quite variable ranges of detection limit, results obtained by high resolution gamma-ray spectrometry based on the assumption of having secular equilibrium between uranium and its daughters, which causes deviation whenever this condition was missed. For samples with reasonable uranium content, neutron activation analysis would be a rapid and reliable technique, while for low uranium content laser fluorimetry would be the most appropriate and accurate technique

  1. Investigating effects of sample pretreatment on protein stability using size-exclusion chromatography and high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Rakow, Tobias; El Deeb, Sami; Hahne, Thomas; El-Hady, Deia Abd; AlBishri, Hassan M; Wätzig, Hermann

    2014-09-01

    In this study, size-exclusion chromatography and high-resolution atomic absorption spectrometry methods have been developed and evaluated to test the stability of proteins during sample pretreatment. This especially includes different storage conditions but also adsorption before or even during the chromatographic process. For the development of the size exclusion method, a Biosep S3000 5 μm column was used for investigating a series of representative model proteins, namely bovine serum albumin, ovalbumin, monoclonal immunoglobulin G antibody, and myoglobin. Ambient temperature storage was found to be harmful to all model proteins, whereas short-term storage up to 14 days could be done in an ordinary refrigerator. Freezing the protein solutions was always complicated and had to be evaluated for each protein in the corresponding solvent. To keep the proteins in their native state a gentle freezing temperature should be chosen, hence liquid nitrogen should be avoided. Furthermore, a high-resolution continuum source atomic absorption spectrometry method was developed to observe the adsorption of proteins on container material and chromatographic columns. Adsorption to any container led to a sample loss and lowered the recovery rates. During the pretreatment and high-performance size-exclusion chromatography, adsorption caused sample losses of up to 33%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS) in Astrobiology-Related Research: Analysis of Meteorites and Tholins.

    Science.gov (United States)

    Somogyi, Árpád; Thissen, Roland; Orthous-Daunay, Francois-Régis; Vuitton, Véronique

    2016-03-24

    It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks ("seeds") for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model) experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT) mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR) mass spectrometers are shown and discussed in the present article, including: (i) the analysis of organic matter of meteorites; (ii) modeling atmospheric processes in ICR cells; and (iii) the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn's largest moon, Titan.

  3. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS in Astrobiology-Related Research: Analysis of Meteorites and Tholins

    Directory of Open Access Journals (Sweden)

    Árpád Somogyi

    2016-03-01

    Full Text Available It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks (“seeds” for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR mass spectrometers are shown and discussed in the present article, including: (i the analysis of organic matter of meteorites; (ii modeling atmospheric processes in ICR cells; and (iii the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn’s largest moon, Titan.

  4. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS) in Astrobiology-Related Research: Analysis of Meteorites and Tholins

    Science.gov (United States)

    Somogyi, Árpád; Thissen, Roland; Orthous-Daunay, Francois-Régis; Vuitton, Véronique

    2016-01-01

    It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks (“seeds”) for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model) experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT) mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR) mass spectrometers are shown and discussed in the present article, including: (i) the analysis of organic matter of meteorites; (ii) modeling atmospheric processes in ICR cells; and (iii) the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn’s largest moon, Titan. PMID:27023520

  5. Multicomponent mixed dopant optimization for rapid screening of polycyclic aromatic hydrocarbons using ultra high performance liquid chromatography coupled to atmospheric pressure photoionization high-resolution mass spectrometry

    KAUST Repository

    Sioud, Salim

    2012-05-04

    RATIONALE To enhance the ionization efficiencies in atmospheric pressure photoionization mass spectrometry a dopant with favorable ionization energy such as chlorobenzene is typically used. These dopants are typically toxic and difficult to mix with water-soluble organic solvents. In order to achieve a more efficient and less toxic dopant, a multicomponent mixed dopant was explored. METHODS A multicomponent mixed dopant for non-targeted rapid screening of polycyclic aromatic hydrocarbons (PAHs) was developed and optimized using ultra high performance liquid chromatography (UPLC) coupled to atmospheric pressure photoionization high-resolution mass spectrometry. Various single and multicomponent mixed dopants consisting of ethanol, chlorobenzene, bromobenzene, anisole and toluene were evaluated. RESULTS Fourteen out of eighteen PAHs were successfully separated and detected at low pg/μL levels within 5 min with high mass accuracy ≤4 ppm. The optimal mixed multicomponent dopant consisted of ethanol/chlorobenzene/bromobenzene/anisole (98.975:0.1:0.9:0.025, v/v %) and it improved the limit of detection (LOD) by 2- to 10-fold for the tested PAHs compared to those obtained with pure chlorobenzene. CONCLUSIONS A novel multicomponent dopant that contains 99% ethanol and 1% mixture of chlorobenzene, bromobenzene and anisole was found to be an effective dopant mixture to ionize PAHs. The developed UPLC multicomponent dopant assisted atmospheric pressure photoionization high-resolution mass spectrometry offered a rapid non targeted screening method for detecting the PAHs at low pg/;μL levels within a 5 min run time with high mass accuracy a;circ4 ppm. Copyright © 2012 John Wiley & Sons, Ltd.

  6. A large-area grid ionisation chamber with high resolution for the measurement of alpha sources in samples with low specific activity

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1978-06-01

    Construction and properties of a gridded ionization chamber for α-paricle spectrometry of low-level large-area samples are presented. Great importance was attached to high spectrometric resolution, low background, long-term stability, simple construction and operation, and easy decontamination if necessary. Using modern charge-sensitive preamplifiers spectrometric resolution is 20,6 keV FWHM (0,4%) at 5,30 MeV over the total effective area of 300 m 2 . Counting gas is an argon-methane mixture (P-10 gas) at atmospheric pressure. Background is 13 cph in the energy interval from 4 to 6 MeV and minimum detectable activity is 0.01 pCi Pu-239 at 1000 min measuring time. Ionization chambers of this type are used for direct α-spectrometric surveillance of long-lived α-emitting nuclides in the atmosphere after electrostatic deposition of the aerosols and for the determination of α-emitting nuclides in the emissions of nuclear power plants. After plasma ashing of the aerosols on filters from the stack monitoring system the minimum detectable concentration of e.g. Pu-239/240 in the gaseous effluent of a nuclear power plant is about 0.1 fCi per m 3 . (orig.) [de

  7. Surface Induced Dissociation Coupled with High Resolution Mass Spectrometry Unveils Heterogeneity of a 211 kDa Multicopper Oxidase Protein Complex

    Science.gov (United States)

    Zhou, Mowei; Yan, Jing; Romano, Christine A.; Tebo, Bradley M.; Wysocki, Vicki H.; Paša-Tolić, Ljiljana

    2018-01-01

    Manganese oxidation is an important biogeochemical process that is largely regulated by bacteria through enzymatic reactions. However, the detailed mechanism is poorly understood due to challenges in isolating and characterizing these unknown enzymes. A manganese oxidase, Mnx, from Bacillus sp. PL-12 has been successfully overexpressed in active form as a protein complex with a molecular mass of 211 kDa. We have recently used surface induced dissociation (SID) and ion mobility-mass spectrometry (IM-MS) to release and detect folded subcomplexes for determining subunit connectivity and quaternary structure. The data from the native mass spectrometry experiments led to a plausible structural model of this multicopper oxidase, which has been difficult to study by conventional structural biology methods. It was also revealed that each Mnx subunit binds a variable number of copper ions. Becasue of the heterogeneity of the protein and limited mass resolution, ambiguities in assigning some of the observed peaks remained as a barrier to fully understanding the role of metals and potential unknown ligands in Mnx. In this study, we performed SID in a modified Fourier transform-ion cyclotron resonance (FTICR) mass spectrometer. The high mass accuracy and resolution offered by FTICR unveiled unexpected artificial modifications on the protein that had been previously thought to be iron bound species based on lower resolution spectra. Additionally, isotopically resolved spectra of the released subcomplexes revealed the metal binding stoichiometry at different structural levels. This method holds great potential for in-depth characterization of metalloproteins and protein-ligand complexes. [Figure not available: see fulltext.

  8. Nuclear energy - Waste-packages activity measurement - Part.1: high-resolution gamma spectrometry in integral mode with open geometry

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 14850:2004 describes a procedure for measurements of gamma-emitting radionuclide activity in homogeneous objects such as unconditioned waste (including process waste, dismantling waste, etc.), waste conditioned in various matrices (bitumen, hydraulic binder, thermosetting resins, etc.), notably in the form of 100 L, 200 L, 400 L or 800 L drums, and test specimens or samples, (vitrified waste), and waste packaged in a container, notably technological waste. It also specifies the calibration of the gamma spectrometry chain. The gamma energies used generally range from 0,05 MeV to 3 MeV. (authors)

  9. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy

    International Nuclear Information System (INIS)

    Wirtz, T; Philipp, P; Audinot, J-N; Dowsett, D; Eswara, S

    2015-01-01

    Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM). (paper)

  10. Studies on the microbial biotransformation of the novel psychoactive substance methylenedioxypyrovalerone (MDPV) in wastewater by means of liquid chromatography-high resolution mass spectrometry/mass spectrometry.

    Science.gov (United States)

    Mardal, Marie; Meyer, Markus R

    2014-09-15

    Sewage profiling as a mean to estimate consumption of drugs of abuse is gaining increasing attention. However, only scarce data are available so far on the impact of microbial biotransformation on the presence and hence detectability of drugs of abuse and their metabolites in wastewater (WW) samples. The aim of this work was therefore to study the biotransformation pathways of the novel psychoactive substance 3,4-methylenedioxypyrovalerone (MPDV) in WW by incubating it, based on the OECD guideline 314 A. MDPV was incubated (100 μg/L) for 10d at 22 °C in WW from a local WW treatment plant. Furthermore, urine and feces collected from rats administered 20mg MDPV/kg BW were incubated correspondingly. Samples were worked-up either by centrifugation/filtration and solid-phase (HCX) extraction or QuEChERS. High resolution (HR) mass spectra (MS) were recorded using an Orbitrap mass spectrometer. All products were identified via their HR-MS(2) spectra and chromatographic properties. The observed biotransformations in WW were: demethylenation and subsequent O-methylation, hydroxylation at the phenyl part, hydroxylation at the pyrrolidine part with subsequent methylation or oxidation, N-demethylation, and hydroxylation at the alkyl part as well as combination of them. In total, 12 biotransformation products were identified after 10 days of incubation. Three of these biotransformation products were previously reported to be also rat and human metabolites. No additional MDPV biotransformation products could be found after incubating the rat urine and feces samples. Instead, the urinary phase II glucuronides were nearly completely cleaved after one day of WW incubation. The presented study indicates that demethylenyl-methyl MDPV, the most abundant metabolite in human urine, should be the best indicator in WW to estimate its use. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Next-generation technologies for spatial proteomics: Integrating ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR imaging mass spectrometry for protein analysis.

    Science.gov (United States)

    Spraggins, Jeffrey M; Rizzo, David G; Moore, Jessica L; Noto, Michael J; Skaar, Eric P; Caprioli, Richard M

    2016-06-01

    MALDI imaging mass spectrometry is a powerful analytical tool enabling the visualization of biomolecules in tissue. However, there are unique challenges associated with protein imaging experiments including the need for higher spatial resolution capabilities, improved image acquisition rates, and better molecular specificity. Here we demonstrate the capabilities of ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR IMS platforms as they relate to these challenges. High spatial resolution MALDI-TOF protein images of rat brain tissue and cystic fibrosis lung tissue were acquired at image acquisition rates >25 pixels/s. Structures as small as 50 μm were spatially resolved and proteins associated with host immune response were observed in cystic fibrosis lung tissue. Ultra-high speed MALDI-TOF enables unique applications including megapixel molecular imaging as demonstrated for lipid analysis of cystic fibrosis lung tissue. Additionally, imaging experiments using MALDI FTICR IMS were shown to produce data with high mass accuracy (z 5000) for proteins up to ∼20 kDa. Analysis of clear cell renal cell carcinoma using MALDI FTICR IMS identified specific proteins localized to healthy tissue regions, within the tumor, and also in areas of increased vascularization around the tumor. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Characterization of Chemical Composition of Pericarpium Citri Reticulatae Volatile Oil by Comprehensive Two-Dimensional Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kunming Qin

    2013-01-01

    Full Text Available Pericarpium Citri Reticulatae (Chenpi in Chinese has been widely used as an herbal medicine in Korea, China, and Japan. Chenpi extracts are used to treat indigestion and inflammatory syndromes of the respiratory tract such as bronchitis and asthma. This thesis will analyze chemical compositions of Chenpi volatile oil, which was performed by comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HR-TOFMS. One hundred and sixty-seven components were tentatively identified, and terpene compounds are the main components of Chenpi volatile oil, a significant larger number than in previous studies. The majority of the eluted compounds, which were identified, were well separated as a result of high-resolution capability of the GC × GC method, which significantly reduces, the coelution. β-Elemene is tentatively qualified by means of GC × GC in tandem with high-resolution TOFMS detection, which plays an important role in enhancing the effects of many anticancer drugs and in reducing the side effects of chemotherapy. This study suggests that GC × GC-HR-TOFMS is suitable for routine characterization of chemical composition of volatile oil in herbal medicines.

  13. Measuring protein synthesis using metabolic ²H labeling, high-resolution mass spectrometry, and an algorithm.

    Science.gov (United States)

    Kasumov, Takhar; Ilchenko, Serguey; Li, Ling; Rachdaoui, Nadia; Sadygov, Rovshan G; Willard, Belinda; McCullough, Arthur J; Previs, Stephen

    2011-05-01

    We recently developed a method for estimating protein dynamics in vivo with heavy water ((2)H(2)O) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) [16], and we confirmed that (2)H labeling of many hepatic free amino acids rapidly equilibrated with body water. Although this is a reliable method, it required modest sample purification and necessitated the determination of tissue-specific amino acid labeling. Another approach for quantifying protein kinetics is to measure the (2)H enrichments of body water (precursor) and protein-bound amino acid or proteolytic peptide (product) and to estimate how many copies of deuterium are incorporated into a product. In the current study, we used nanospray linear trap Fourier transform ion cyclotron resonance mass spectrometry (LTQ FT-ICR MS) to simultaneously measure the isotopic enrichment of peptides and protein-bound amino acids. A mathematical algorithm was developed to aid the data processing. The most notable improvement centers on the fact that the precursor/product labeling ratio can be obtained by measuring the labeling of water and a protein (or peptide) of interest, thereby minimizing the need to measure the amino acid labeling. As a proof of principle, we demonstrate that this approach can detect the effect of nutritional status on albumin synthesis in rats given (2)H(2)O. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. High mass and spatial resolution mass spectrometry imaging of Nicolas Poussin painting cross section by cluster TOF-SIMS.

    Science.gov (United States)

    Noun, M; Van Elslande, E; Touboul, D; Glanville, H; Bucklow, S; Walter, P; Brunelle, A

    2016-12-01

    The painting Rebecca and Eliezer at the Well, which hangs in the Fitzwilliam Museum, Cambridge, UK, is possibly one of the last figure painting executed by Nicolas Poussin at the very end of his life and is usually dated to the early 1660s. In this perspective special feature, Philippe Walter, Alain Brunelle and colleagues give new insights on the artist's working methods by a careful stateof-the-art imaging ToF-SIMS study of one sample taken on the edge of the painting. This approach allowed for the identification of the pigments used in the painting, their nature and components and those of the ground and preparatory layers, with the identification of the binder(s) and possible other additions of organic materials such as glue. This study paves the way to a wider use of ToF-SIMS for the analysis of ancient cultural heritage artefacts. Dr. Walter is the Director of the Molecular and Structural Archeology Laboratory (Université Pierre et Marie Curie, Paris, France). Dr. Brunelle is Head of the Mass Spectrometry Laboratory at the Institut de Chimie des Substances Naturelles (CNRS, Gif-sur-Yvette, France). Their long standing collaboration has led to several seminal publications on the analysis of ancient artefacts by mass spectrometry. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Investigating the presence of omeprazole in waters by liquid chromatography coupled to low and high resolution mass spectrometry: degradation experiments.

    Science.gov (United States)

    Boix, C; Ibáñez, M; Sancho, J V; Niessen, W M A; Hernández, F

    2013-10-01

    Omeprazole is one of the most consumed pharmaceuticals around the world. However, this compound is scarcely detected in urban wastewater and surface water. The absence of this pharmaceutical in the aquatic ecosystem might be due to its degradation in wastewater treatment plants, as well as in receiving water. In this work, different laboratory-controlled degradation experiments have been carried out on surface water in order to elucidate generated omeprazole transformation products (TPs). Surface water spiked with omeprazole was subjected to hydrolysis, photo-degradation under both sunlight and ultraviolet radiation and chlorination. Analyses by liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QTOF MS) permitted identification of up to 17 omeprazole TPs. In a subsequent step, the TPs identified were sought in surface water and urban wastewater by LC-QTOF MS and by LC coupled to tandem mass spectrometry with triple quadrupole. The parent omeprazole was not detected in any of the samples, but four TPs were found in several water samples. The most frequently detected compound was OTP 5 (omeprazole sulfide), which might be a reasonable candidate to be included in monitoring programs rather than the parent omeprazole. Copyright © 2013 John Wiley & Sons, Ltd.

  16. Application of Micro-coprecipitation Method to Alpha Source Preparation for Measuring Alpha Nuclides

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Park, Jong Ho; Oh, Se Jin; Song, Byung Chul; Song, Kyuseok

    2011-01-01

    Among the source preparations, an electrodeposition is a commonly used method for the preparation of sources for an alpha spectrometry, because this technique is simple and produces a very thin deposit, which is essential for a high resolution of the alpha peak. Recently, micro-coprecipitation with rare earths have been used to yield sources for -spectrometry. In this work, the Pu, Am and Cm isotopes were purified from hindrance nuclides and elements with an a TRU resin in radioactive waste samples, and the activity concentrations of the Pu, Am and Cm isotopes were determined by radiation counting methods after alpha source preparation like micro coprecipitation. After the Pu isotopes in the radioactive waste samples were separated from the other nuclides with an anion exchange resin, the Am isotopes were purified with a TRU resin and an anion exchange resin or a TRU resin. Activity concentrations and chemical recoveries of 241 Am purified with the TRU resin were similar to those with the TRU resin and anion exchange resin. In this study, to save on the analytical time and cost, the Am isotopes were purified with the TRU resin without using an additional anion exchange resin. After comparing the electrodeposition method with the micro-coprecipitation method, the micro-coprecipitation method was used for the alpha source preparation, because the micro-coprecipitation method is simple and more reliable for source preparation of the Pu, Am and Cm isotopes

  17. Position sensitive detection coupled to high-resolution time-of-flight mass spectrometry: Imaging for molecular beam deflection experiments

    International Nuclear Information System (INIS)

    Abd El Rahim, M.; Antoine, R.; Arnaud, L.; Barbaire, M.; Broyer, M.; Clavier, Ch.; Compagnon, I.; Dugourd, Ph.; Maurelli, J.; Rayane, D.

    2004-01-01

    We have developed and tested a high-resolution time-of-flight mass spectrometer coupled to a position sensitive detector for molecular beam deflection experiments. The major achievement of this new spectrometer is to provide a three-dimensional imaging (X and Y positions and time-of-flight) of the ion packet on the detector, with a high acquisition rate and a high resolution on both the mass and the position. The calibration of the experimental setup and its application to molecular beam deflection experiments are discussed

  18. A comprehensive high-resolution mass spectrometry approach for characterization of metabolites by combination of ambient ionization, chromatography and imaging methods.

    Science.gov (United States)

    Berisha, Arton; Dold, Sebastian; Guenther, Sabine; Desbenoit, Nicolas; Takats, Zoltan; Spengler, Bernhard; Römpp, Andreas

    2014-08-30

    An ideal method for bioanalytical applications would deliver spatially resolved quantitative information in real time and without sample preparation. In reality these requirements can typically not be met by a single analytical technique. Therefore, we combine different mass spectrometry approaches: chromatographic separation, ambient ionization and imaging techniques, in order to obtain comprehensive information about metabolites in complex biological samples. Samples were analyzed by laser desorption followed by electrospray ionization (LD-ESI) as an ambient ionization technique, by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging for spatial distribution analysis and by high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) for quantitation and validation of compound identification. All MS data were acquired with high mass resolution and accurate mass (using orbital trapping and ion cyclotron resonance mass spectrometers). Grape berries were analyzed and evaluated in detail, whereas wheat seeds and mouse brain tissue were analyzed in proof-of-concept experiments. In situ measurements by LD-ESI without any sample preparation allowed for fast screening of plant metabolites on the grape surface. MALDI imaging of grape cross sections at 20 µm pixel size revealed the detailed distribution of metabolites which were in accordance with their biological function. HPLC/ESI-MS was used to quantify 13 anthocyanin species as well as to separate and identify isomeric compounds. A total of 41 metabolites (amino acids, carbohydrates, anthocyanins) were identified with all three approaches. Mass accuracy for all MS measurements was better than 2 ppm (root mean square error). The combined approach provides fast screening capabilities, spatial distribution information and the possibility to quantify metabolites. Accurate mass measurements proved to be critical in order to reliably combine data from different MS

  19. Impurity profiling of liothyronine sodium by means of reversed phase HPLC, high resolution mass spectrometry, on-line H/D exchange and UV/Vis absorption.

    Science.gov (United States)

    Ruggenthaler, M; Grass, J; Schuh, W; Huber, C G; Reischl, R J

    2017-09-05

    For the first time, a comprehensive investigation of the impurity profile of the synthetic thyroid API (active pharmaceutical ingredient) liothyronine sodium (LT 3 Na) was performed by using reversed phase HPLC and advanced structural elucidation techniques including high resolution tandem mass spectrometry (HRMS/MS) and on-line hydrogen-deuterium (H/D) exchange. Overall, 39 compounds were characterized and 25 of these related substances were previously unknown to literature. The impurity classification system recently developed for the closely related API levothyroxine sodium (LT 4 Na) could be applied to the newly characterized liothyronine sodium impurities resulting in a wholistic thyroid API impurity classification system. Furthermore, the mass-spectrometric CID-fragmentation of specific related substances was discussed and rationalized by detailed fragmentation pathways. Moreover, the UV/Vis absorption characteristics of the API and selected impurities were investigated to corroborate chemical structure assignments derived from MS data. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Fast and sensitive analysis of beta blockers by ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry.

    Science.gov (United States)

    Tomková, Jana; Ondra, Peter; Kocianová, Eva; Václavík, Jan

    2017-07-01

    This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients. Copyright © 2016 John Wiley & Sons, Ltd.

  1. HighResNPS.com – an Internet Database for Liquid Chromatography - High Resolution Mass Spectrometry Screening for New Psychoactive Substances

    DEFF Research Database (Denmark)

    Dalsgaard, Petur Weihe; Mollerup, Christian Brinch; Mardal, Marie

    /Discussions: . The overlapping entries of the database verify that similar fragment ions can be observed from identical compounds across different LC-HRMS systems. The inclusion of fragment ions from other labs can reduce false positive identifications, when no reference standard is available in-house. HighResNPS can serve......Background/Introduction: The number of new psychoactive substances (NPS) is constantly increasing which makes it challenging to keep the screening libraries updated with the relevant analytical targets. Liquid chromatography coupled High Resolution Mass Spectrometry (LC-HRMS) screening methods...... with most screening platforms after minor formatting. Results: Currently, 11 users from 9 laboratories in 7 counties have contributed with 318 entries to the database with experimental data containing at least one fragment ion. 66% of the uploaded data were based on reference standards. Synthetic...

  2. Exploring the potential of high resolution mass spectrometry for the investigation of lignin-derived phenol substitutes in phenolic resin syntheses.

    Science.gov (United States)

    Dier, Tobias K F; Fleckenstein, Marco; Militz, Holger; Volmer, Dietrich A

    2017-05-01

    Chemical degradation is an efficient method to obtain bio-oils and other compounds from lignin. Lignin bio-oils are potential substitutes for the phenol component of phenol formaldehyde (PF) resins. Here, we developed an analytical method based on high resolution mass spectrometry that provided structural information for the synthesized lignin-derived resins and supported the prediction of their properties. Different model resins based on typical lignin degradation products were analyzed by electrospray ionization in negative ionization mode. Utilizing enhanced mass defect filter techniques provided detailed structural information of the lignin-based model resins and readily complemented the analytical data from differential scanning calorimetry and thermogravimetric analysis. Relative reactivity and chemical diversity of the phenol substitutes were significant determinants of the outcome of the PF resin synthesis and thus controlled the areas of application of the resulting polymers. Graphical abstract ᅟ.

  3. Gas chromatography-mass spectrometry of ethyl palmitate calibration and resolution with ethyl oleate as biomarker ethanol sub acute in urine application study

    Science.gov (United States)

    Suaniti, Ni Made; Manurung, Manuntun

    2016-03-01

    Gas Chromatography-Mass Spectrometry is used to separate two and more compounds and identify fragment ion specific of biomarker ethanol such as palmitic acid ethyl ester (PAEE), as one of the fatty acid ethyl esters as early detection through conyugated reaction. This study aims to calibrate ethyl palmitate and develop analysis with oleate acid. This methode can be used analysis ethanol and its chemistry biomarker in ethanol sub-acute consumption as analytical forensic toxicology. The result show that ethanol level in urine rats Wistar were 9.21 and decreased 6.59 ppm after 48 hours consumption. Calibration curve of ethyl palmitate was y = 0.2035 x + 1.0465 and R2 = 0.9886. Resolution between ethyl palmitate and oleate were >1.5 as good separation with fragment ion specific was 88 and the retention time was 18 minutes.

  4. Identification/quantification of free and bound phenolic acids in peel and pulp of apples (Malus domestica) using high resolution mass spectrometry (HRMS).

    Science.gov (United States)

    Lee, Jihyun; Chan, Bronte Lee Shan; Mitchell, Alyson E

    2017-01-15

    Free and bound phenolic acids were measured in the pulp and peel of four varieties of apples using high resolution mass spectrometry. Twenty-five phenolic acids were identified and included: 8 hydroxybenzoic acids, 11 hydroxycinnamic acids, 5 hydroxyphenylacetic acids, and 1 hydoxyphenylpropanoic acid. Several phenolics are tentatively identified for the first time in apples and include: methyl gallate, ethyl gallate, hydroxy phenyl acetic acid, three phenylacetic acid isomers, 3-(4-hydroxyphenyl)propionic acid, and homoveratric acid. With exception of chlorogenic and caffeic acid, most phenolic acids were quantified for the first time in apples. Significant varietal differences (pacids were higher in the pulp as compared to apple peel (dry weight) in all varieties. Coumaroylquinic, protocatechuic, 4-hydroxybenzoic, vanillic and t-ferulic acids were present in free forms. With exception of chlorogenic acid, all other phenolic acids were present only as bound forms. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. An Investigation of the Complexity of Maillard Reaction Product Profiles from the Thermal Reaction of Amino Acids with Sucrose Using High Resolution Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Agnieszka Golon

    2014-08-01

    Full Text Available Thermal treatment of food changes its chemical composition drastically with the formation of “so-called” Maillard reaction products, being responsible for the sensory properties of food, along with detrimental and beneficial health effects. In this contribution, we will describe the reactivity of several amino acids, including arginine, lysine, aspartic acid, tyrosine, serine and cysteine, with carbohydrates. The analytical strategy employed involves high and ultra-high resolution mass spectrometry followed by chemometric-type data analysis. The different reactivity of amino acids towards carbohydrates has been observed with cysteine and serine, resulting in complex MS spectra with thousands of detectable reaction products. Several compounds have been tentatively identified, including caramelization reaction products, adducts of amino acids with carbohydrates, their dehydration and hydration products, disproportionation products and aromatic compounds based on molecular formula considerations.

  6. Identification of Organic Iodine Compounds and Their Transformation Products in Edible Iodized Salt Using Liquid Chromatography-High Resolution Mass Spectrometry.

    Science.gov (United States)

    Yun, Lifen; Peng, Yue'e; Chang, Qing; Zhu, Qingxin; Guo, Wei; Wang, Yanxin

    2017-07-05

    The consumption of edible iodized salt is a key strategy to control and eliminate iodine deficiency disorders worldwide. We herein report the identification of the organic iodine compounds present in different edible iodized salt products using liquid chromatography combined with high resolution mass spectrometry. A total of 38 organic iodine compounds and their transformation products (TPs) were identified in seaweed iodine salt from China. Our experiments confirmed that the TPs were generated by the replacement of I atoms from organic iodine compounds with Cl atoms. Furthermore, the organic iodine compound contents in 4 seaweed iodine salt samples obtained from different manufacturers were measured, with significant differences in content being observed. We expect that the identification of organic iodine compounds in salt will be important for estimating the validity and safety of edible iodized salt products.

  7. High-throughput screening and confirmation of 22 banned veterinary drugs in feedstuffs using LC-MS/MS and high-resolution Orbitrap mass spectrometry.

    Science.gov (United States)

    Wang, Xufeng; Liu, Yanghong; Su, Yijuan; Yang, Jianwen; Bian, Kui; Wang, Zongnan; He, Li-Min

    2014-01-15

    A new analytical strategy based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) combined with accurate mass high-resolution Orbitrap mass spectrometry (HR-Orbitrap MS) was performed for high-throughput screening, confirmation, and quantification of 22 banned or unauthorized veterinary drugs in feedstuffs according to Bulletin 235 of the Ministry of Agriculture, China. Feed samples were extracted with acidified acetonitrile, followed by cleanup using solid-phase extraction cartridge. The extracts were first screened by LC-MS/MS in a single selected reaction monitoring mode. The suspected positive samples were subjected to a specific pretreatment for confirmation and quantification of analyte of interest with LC-MS/MS and HR-Orbitrap MS. Mean recoveries for all target analytes (except for carbofuran and chlordimeform, which were about 35 and 45%, respectively) ranged from 52.2 to 90.4%, and the relative standard deviations were screening of real samples obtained from local feed markets and confirmation of the suspected target analytes. It provides a high-throughput, sensitive, and reliable screening, identification, and quantification of banned veterinary drugs in routine monitoring programs of feedstuffs.

  8. Liquid chromatography with high resolution mass spectrometry for identification of organic contaminants in fish fillet: screening and quantification assessment using two scan modes for data acquisition.

    Science.gov (United States)

    Munaretto, Juliana S; May, Marília M; Saibt, Nathália; Zanella, Renato

    2016-07-22

    This study proposed a strategy to identify and quantify 182 organic contaminants from different chemical classes, as for instance pesticides, veterinary drug and personal care products, in fish fillet using liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QToF/MS). For this purpose, two different scan methods (full scan and all ions MS/MS) were evaluated to assess the best option for screening analysis in spiked fish fillet samples. In general, full scan acquisition was found to be more reliable (84%) in the automatic identification and quantification when compared to all ions MS/MS with 72% of the compounds detected. Additionally, a qualitative automatic search showed a mass accuracy error below 5ppm for 77% of the compounds in full scan mode compared to only 52% in all ions MS/MS scan. However, all ions MS/MS provides fragmentation information of the target compounds. Undoubtedly, structural information of a wide number of compounds can be obtained using high resolution mass spectrometry (HRMS), but it is necessary thoroughly assess it, in order to choose the best scan mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid profiling of antimicrobial compounds characterising B. subtilis TR50 cell-free filtrate by high-performance liquid chromatography coupled to high-resolution Orbitrap™ mass spectrometry.

    Science.gov (United States)

    Monaci, Linda; Quintieri, Laura; Caputo, Leonardo; Visconti, Angelo; Baruzzi, Federico

    2016-01-15

    Several Bacillus strains, typically isolated from different food sources, represent renowned producers of a multitude of low and high molecular weight compounds, including lipopeptides and macrolactones, with an importance for their antimicrobial activity. The high homology shared by many of these compounds also occurring as closely related isoforms poses a challenge in their prompt detection. Identification and structural elucidation is generally achieved by matrix-assisted laser desorption/ionization (MALDI) or liquid chromatography (LC) coupled to mass spectrometry (MS) after a pre-fractionation and/or purification step of the extract. In this paper we report the application of a method based on LC separation and high-resolution Orbitrap™-based MS for the rapid screening of raw filtrate of the strain Bacillus subtilis TR50 endowed with antimicrobial activity, without requiring any sample pre-treatment. Upon direct analysis of the cell-free filtrate of Bacillus subtilis TR50 by high-resolution mass spectrometry (HRMS), different compounds families, that proved to exert a remarked antimicrobial activity against several foodborne pathogens, can be readily displayed along the chromatographic run. Among them, three different classes were identified and characterized belonging to the iturin, fengycin and surfactin groups. The high resolving power and accurate mass accuracy provided by the HRMS system in use ensured an enhanced selectivity compared to other mass spectrometers. In addition, after activation of the HCD cell, the HR-MS/MS spectra can provide insights in the structural elucidation of several compounds. The acquisition of HRMS spectra of raw filtrates of subtilis strains allows untargeted analysis of the major classes of compounds produced to be performed, thus facilitating identification of other unknown bioactive molecules after retrospective analysis. These features make this approach a fast tool applicable to the rapid screening and further

  10. Multi-allergen quantification of fining-related egg and milk proteins in white wines by high-resolution mass spectrometry.

    Science.gov (United States)

    Monaci, Linda; Losito, Ilario; De Angelis, Elisabetta; Pilolli, Rosa; Visconti, Angelo

    2013-09-15

    A method based on High-Resolution Mass Spectrometry was developed for the simultaneous determination of fining agents containing potentially allergenic milk (casein) and egg-white (lysozyme and ovalbumin) proteins, added to commercial white wines at sub-ppm levels. Selected tryptic peptides were used as quantitative markers. An evaluation of protein digestion yields was also performed by implementing the (15)N-valine-labelled analogues of the best peptide markers identified for αS1 -casein and ovalbumin. The method was based on the combination of ultrafiltration (UF) of protein-containing wines, tryptic digestion of the dialyzed wine extracts and liquid chromatography/high resolution mass spectrometry (LC/HRMS) analysis of tryptic digests. Peptides providing the most intense electrospray ionization (ESI)-MS response were chosen as quantitative markers of the proteins under investigation. Six-point calibrations were performed by adding caseinate and egg-white powder in the concentration range between 0.25 and 10 µg/mL, to an allergen-free white wine. The following three peptide markers, LTEWTSSNVMEER, GGLEPINFQTAADQAR and ELINSWVESQTNGIIR, were highlighted as best markers for ovalbumin, while GTDVQAWIR and NTDGSTDYGILQINSR for lysozyme and YLGYLEQLLR, GPFPIIV and FFVAPFPEVFGK for caseinate. Limits of detection (LODs) ranged from 0.4 to 1.1 µg/mL. The developed method is suited for assessing the contemporary presence of allergenic milk and egg proteins characterizing egg white and caseinate, fining agents typically employed for wine clarification. The LODs of the method enable the detection of sub-ppm concentrations of residual fining agents, that could represent a potential risk for allergic consumers. Copyright © 2013 John Wiley & Sons, Ltd.

  11. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    OpenAIRE

    2011-01-01

    Abstract In the present work, a liquid chromatography- high resolution mass spectrometry method was developed for the screening in meat of a wide range of antibiotics used in veterinary medicine. Full scan mode under high resolution mass spectral conditions using LTQ-Orbitrap mass spectrometer with resolving power 60.000 FWHM was applied for analysis of the samples. Samples were prepared using two extractions protocols prior to LC-MS analysis. The scope of the method focuses on the...

  12. The performance of atmospheric pressure gas chromatography-tandem mass spectrometry compared to gas chromatography-high resolution mass spectrometry for the analysis of polychlorinated dioxins and polychlorinated biphenyls in food and feed samples.

    Science.gov (United States)

    Ten Dam, Guillaume; Pussente, Igor Cabreira; Scholl, Georges; Eppe, Gauthier; Schaechtele, Alexander; van Leeuwen, Stefan

    2016-12-16

    Recently, gas chromatography tandem mass spectrometry (GC-MS/MS) has been added in European Union (EU) legislation as an alternative to magnetic sector high resolution mass spectrometry (HRMS) for the analysis of dioxins and dioxin like polychlorinated biphenyls (dl-PCB) in food and feed. In this study the performance of APGC-MS/MS compared to GC-HRMS is investigated and compared with EU legislation. The study includes the legislative parameters, relative intermediate precision standard deviation (S Rw ,rel), trueness, sensitivity, linear range and ion ratio tolerance. In addition, over 200 real samples of large variety and spanning several orders of magnitude in concentration were analyzed by both techniques and the selectivity was evaluated by comparing chromatograms. The S Rw ,rel and trueness were evaluated using (in-house) reference samples and fulfill to EU legislation, though the S Rw ,rel was better with GC-HRMS. The sensitivity was considerably better than of GC-HRMS while the linear range was similar. Ion ratios were mostly within the tolerable range of ±15%. A (temporary unresolved) systematic deviation in ion ratio was observed for several congeners, yet this did not lead to exceeding of the maximum ion ratio limits. The APGC-MS/MS results for the non-dioxin-like-PCBs (ndl-PCBs) were negatively biased, particularly for PCB138 and 153 in contaminated samples. The selectivity of APGC-MS/MS was lower for several matrices. Particularly for contaminated samples, interfering peaks were observed in the APGC chromatograms of the native compounds (dioxins) and labeled internal standards (PCBs). These can lead to biased results and ultimately to false positive samples. It was concluded that the determination of dioxins and PCBs using APGC-MS/MS meets the requirements set by the European Commission. However, due to generally better selectivity and S Rw ,rel, GC-HRMS is the preferred method for monitoring purposes. Copyright © 2016 Elsevier B.V. All rights

  13. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Feng

    2013-01-01

    Full Text Available Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  14. In house validation of a high resolution mass spectrometry Orbitrap-based method for multiple allergen detection in a processed model food.

    Science.gov (United States)

    Pilolli, Rosa; De Angelis, Elisabetta; Monaci, Linda

    2018-02-13

    In recent years, mass spectrometry (MS) has been establishing its role in the development of analytical methods for multiple allergen detection, but most analyses are being carried out on low-resolution mass spectrometers such as triple quadrupole or ion traps. In this investigation, performance provided by a high resolution (HR) hybrid quadrupole-Orbitrap™ MS platform for the multiple allergens detection in processed food matrix is presented. In particular, three different acquisition modes were compared: full-MS, targeted-selected ion monitoring with data-dependent fragmentation (t-SIM/dd2), and parallel reaction monitoring. In order to challenge the HR-MS platform, the sample preparation was kept as simple as possible, limited to a 30-min ultrasound-aided protein extraction followed by clean-up with disposable size exclusion cartridges. Selected peptide markers tracing for five allergenic ingredients namely skim milk, whole egg, soy flour, ground hazelnut, and ground peanut were monitored in home-made cookies chosen as model processed matrix. Timed t-SIM/dd2 was found the best choice as a good compromise between sensitivity and accuracy, accomplishing the detection of 17 peptides originating from the five allergens in the same run. The optimized method was validated in-house through the evaluation of matrix and processing effects, recoveries, and precision. The selected quantitative markers for each allergenic ingredient provided quantification of 60-100 μg ingred /g allergenic ingredient/matrix in incurred cookies.

  15. Setting up of a liquid chromatography-high resolution tandem mass spectrometry method for the detection of caseins in food. A comparison with ELISA method

    Directory of Open Access Journals (Sweden)

    Daniela Gastaldi

    2013-06-01

    Full Text Available Determination of caseins in food matrices is usually performed by using the competitiveenzyme- linked immunosorbent assay (ELISA technique. However such a technique suffers from a number of limitations. Among these, the applicability to a narrow concentration range, a non linear (logarithmic response, a non-negligible cross-reactivity and a high cost per kit. At the time of the completion of this study, in case of ELISA positive feedback, there was poor availability in the literature of finding reliable instrumental methods able to determine both qualitatively and quantitatively this class of substances. In the present study, a liquid chromatography-high resolution tandem mass spectrometry (HPLC-HRMS/MS instrumental method was developed with a high resolution mass spectrometer (Orbitrap. Real samples of sausages in which caseins were detected by ELISA technique were analysed. A casein-free sample of ham was used as a blank. The analytical characteristics of the instrumental method were compared with those of a commercial ELISA test, declared specific for α- and β-casein.

  16. Comparative Analysis of the Volatile Components of Agrimonia eupatoria from Leaves and Roots by Gas Chromatography-Mass Spectrometry and Multivariate Curve Resolution.

    Science.gov (United States)

    Feng, Xiao-Liang; He, Yun-Biao; Liang, Yi-Zeng; Wang, Yu-Lin; Huang, Lan-Fang; Xie, Jian-Wei

    2013-01-01

    Gas chromatography-mass spectrometry and multivariate curve resolution were applied to the differential analysis of the volatile components in Agrimonia eupatoria specimens from different plant parts. After extracted with water distillation method, the volatile components in Agrimonia eupatoria from leaves and roots were detected by GC-MS. Then the qualitative and quantitative analysis of the volatile components in the main root of Agrimonia eupatoria was completed with the help of subwindow factor analysis resolving two-dimensional original data into mass spectra and chromatograms. 68 of 87 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 87.03% of the total content. Then, the common peaks in leaf were extracted with orthogonal projection resolution method. Among the components determined, there were 52 components coexisting in the studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprint. It was the first time to apply orthogonal projection method to compare different plant parts of Agrimonia eupatoria, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex Agrimonia eupatoria samples. The developed method can be used to further study and quality control of Agrimonia eupatoria.

  17. Molecular-level characterization of crude oil compounds combining reversed-phase high-performance liquid chromatography with off-line high-resolution mass spectrometry

    Science.gov (United States)

    Sim, Arum; Cho, Yunju; Kim, Daae; Witt, Matthias; Birdwell, Justin E.; Kim, Byung Ju; Kim, Sunghwan

    2014-01-01

    A reversed-phase separation technique was developed in a previous study (Loegel et al., 2012) and successfully applied to the de-asphalted fraction of crude oil. However, to the best of our knowledge, the molecular-level characterization of oil fractions obtained by reversed-phase high-performance liquid chromatography (HPLC) coupled with high-resolution mass spectrometry (MS) has not yet been reported. A detailed characterization of the oil fractions prepared by reversed-phase HPLC was performed in this study. HPLC fractionation was carried out on conventional crude oil and an oil shale pyrolysate. The analyses of the fractions showed that the carbon number of alkyl chains and the double bond equivalent (DBE) value were the major factors determining elution order. The compounds with larger DBE (presumably more condensed aromatic structures) and smaller carbon number (presumably compounds with short side chains) were eluted earlier but those compounds with lower DBE values (presumably less aromatic structures) and higher carbon number (presumably compounds with longer alkyl chains) eluted later in the chromatograms. This separation behavior is in good agreement with that expected from the principles of reversed-phase separation. The data presented in this study show that reversed-phase chromatography is effective in separating crude oil compounds and can be combined with ultrahigh-resolution MS data to better understand natural oils and oil shale pyrolysates.

  18. Improved resolution of hydrocarbon structures and constitutional isomers in complex mixtures using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry (GC-VUV-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Aerosol Dynamics Inc; Aerodyne Research, Inc.,; Tofwerk AG, Thun; Isaacman, Gabriel; Wilson, Kevin R.; Chan, Arthur W. H.; Worton, David R.; Kimmel, Joel R.; Nah, Theodora; Hohaus, Thorsten; Gonin, Marc; Kroll, Jesse H.; Worsnop, Doug R.; Goldstein, Allen H.

    2011-09-13

    Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography-mass spectrometry (GC-MS) techniques. This work uses vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally"unresolved complex mixture" by separating components by GC retention time, tR, and mass-to-charge ratio, m/Q, which are used to determine carbon number, NC, and the number of rings and double bonds, NDBE. Constitutional isomers are resolved based on tR, enabling the most complete quantitative analysis to date of structural isomers in an environmentally-relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. The classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

  19. Tentative identification of polar and mid-polar compounds in extracts from wine lees by liquid chromatography-tandem mass spectrometry in high-resolution mode.

    Science.gov (United States)

    Delgado de la Torre, M P; Priego-Capote, F; Luque de Castro, M D

    2015-06-01

    Sustainable agriculture has a pending goal in the revalorization of agrofood residues. Wine lees are an abundant residue in the oenological industry. This residue, so far, has been used to obtain tartaric acid or pigments but not for being qualitatively characterized as a source of polar and mid-polar compounds such as flavonoids, phenols and essential amino acids. Lees extracts from 11 Spanish wineries have been analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in high resolution mode. The high-resolution power of LC-MS/MS has led to the tentative identification of the most representative compounds present in wine lees, comprising primary amino acids, anthocyans, flavanols, flavonols, flavones and non-flavonoid phenolic compounds, among others. Attending to the profile and content of polar and mid-polar compounds in wine lees, this study underlines the potential of wine lees as an exploitable source to isolate interesting compounds. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans using simultaneous dual gas chromatography-high resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tirler, W.; Voto, G.; Donega, M. [Eco-Research, Bolzano (Italy)

    2004-09-15

    Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) are two classes of environmental contaminants. Seventeen congeners exist that are substituted in the 2,3,7,8 position and are considered to be the most toxic. Due to the large number (210) of compounds of the PCDD/F family, gas chromatographic (GC) separation of these from the cluster of less toxic isomers is a difficult task. At present no commercially available column can separate all 2,3,7,8 substituted congeners from the remaining PCDD/F. The co elution of less toxic with toxic congeners can cause false TEQ related results, because mass spectrometry cannot differentiate between toxic and non toxic congeners within the same homologous group. To overcome this, the analysis is performed using at least two capillary GC columns, of different polarity. Non polar columns can separate chlorine homologous groups and all toxic congeners from each other but not from all nontoxic congeners. Thus, a polar column should be used in addition for specific separation. Exchange of a GC column on a HRGC-HRMS system is usually a time consuming procedure. Significant time saving can be achieved using a mass spectrometer coupled to two GCs, that allows switching between two different GC columns, without disturbing the measurement conditions of the mass spectrometer. The aim of the present work was to develop a method that permits to work simultaneously with both GCs in order to further improve time savings.

  1. Metabolism of clofibric acid in zebrafish embryos (Danio rerio) as determined by liquid chromatography-high resolution-mass spectrometry.

    Science.gov (United States)

    Brox, Stephan; Seiwert, Bettina; Haase, Nora; Küster, Eberhard; Reemtsma, Thorsten

    2016-01-01

    The zebrafish embryo (ZFE) is increasingly used in ecotoxicology research but detailed knowledge of its metabolic potential is still limited. This study focuses on the xenobiotic metabolism of ZFE at different life-stages using the pharmaceutical compound clofibric acid as study compound. Liquid chromatography with quadrupole-time-of-flight mass spectrometry (LC-QToF-MS) is used to detect and to identify the transformation products (TPs). In screening experiments, a total of 18 TPs was detected and structure proposals were elaborated for 17 TPs, formed by phase I and phase II metabolism. Biotransformation of clofibric acid by the ZFE involves conjugation with sulfate or glucuronic acid, and, reported here for the first time, with carnitine, taurine, and aminomethanesulfonic acid. Further yet unknown cyclization products were identified using non-target screening that may represent a new detoxification pathway. Sulfate containing TPs occurred already after 3h of exposure (7hpf), and from 48h of exposure (52hpf) onwards, all TPs were detected. The detection of these TPs indicates the activity of phase I and phase II enzymes already at early life-stages. Additionally, the excretion of one TP into the exposure medium was observed. The results of this study outline the high metabolic potential of the ZFE with respect to the transformation of xenobiotics. Similarities but also differences to other test systems were observed. Biotransformation of test chemicals in toxicity testing with ZFE may therefore need further consideration. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Ganglioside Composition in Beef, Chicken, Pork, and Fish Determined Using Liquid Chromatography-High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Fong, Bertram Y; Ma, Lin; Khor, Geok Lin; van der Does, Yvonne; Rowan, Angela; McJarrow, Paul; MacGibbon, Alastair K H

    2016-08-17

    Gangliosides (GA) are found in animal tissues and fluids, such as blood and milk. These sialo-glycosphingolipids have bioactivities in neural development, the gastrointestinal tract, and the immune system. In this study, a high-performance liquid chromatography-mass spectrometry (HPLC-MS) method was validated to characterize and quantitate the GA in beef, chicken, pork, and fish species (turbot, snapper, king salmon, and island mackerel). For the first time, we report the concentration of GM3, the dominant GA in these foods, as ranging from 0.35 to 1.1 mg/100 g and 0.70 to 5.86 mg/100 g of meat and fish, respectively. The minor GAs measured were GD3, GD1a, GD1b, and GT1b. Molecular species distribution revealed that the GA contained long- to very-long-chain acyl fatty acids attached to the ceramide moiety. Fish GA contained only N-acetylneuraminic acid (NeuAc) sialic acid, while beef, chicken, and pork contained GD1a/b species that incorporated both NeuAc and N-glycolylneuraminic acid (NeuGc) and hydroxylated fatty acids.

  3. Ultra-high-performance liquid chromatography-Time-of-flight high resolution mass spectrometry to quantify acidic drugs in wastewater.

    Science.gov (United States)

    Becerra-Herrera, Mercedes; Honda, Luis; Richter, Pablo

    2015-12-04

    A novel analytical approach involving an improved rotating-disk sorptive extraction (RDSE) procedure and ultra-high-performance liquid chromatography (UHPLC) coupled to an ultraspray electrospray ionization source (UESI) and time-of-flight mass spectrometry (TOF/MS), in trap mode, was developed to identify and quantify four non-steroidal anti-inflammatory drugs (NSAIDs) (naproxen, ibuprofen, ketoprofen and diclofenac) and two anti-cholesterol drugs (ACDs) (clofibric acid and gemfibrozil) that are widely used and typically found in water samples. The method reduced the amount of both sample and reagents used and also the time required for the whole analysis, resulting in a reliable and green analytical strategy. The analytical eco-scale was calculated, showing that this methodology is an excellent green analysis, increasing its ecological worth. The detection limits (LOD) and precision (%RSD) were lower than 90ng/L and 10%, respectively. Matrix effects and recoveries were studied using samples from the influent of a wastewater treatment plant (WWTP). All the compounds exhibited suppression of their signals due to matrix effects, and the recoveries were approximately 100%. The applicability and reliability of this methodology were confirmed through the analysis of influent and effluent samples from a WWTP in Santiago, Chile, obtaining concentrations ranging from 1.1 to 20.5μg/L and from 0.5 to 8.6μg/L, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Profiling of Histone Post-Translational Modifications in Mouse Brain with High-Resolution Top-Down Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Mowei; Paša-Tolić, Ljiljana; Stenoien, David L.

    2016-12-21

    Histones play central roles in most chromosomal functions and both their basic biology and roles in disease have been the subject of intense study. Since multiple PTMs along the entire protein sequence are potential regulators of histones, a top-down approach, where intact proteins are analyzed, is ultimately required for complete characterization of proteoforms. However, significant challenges remain for top-down histone analysis primarily because of deficiencies in separation/resolving power and effective identification algorithms. Here, we used state of the art mass spectrometry and a bioinformatics workflow for targeted data analysis and visualization. The workflow uses ProMex for intact mass deconvolution, MSPathFinder as search engine, and LcMsSpectator as a data visualization tool. ProMex sums across retention time to maximize sensitivity and accuracy for low abundance species in MS1deconvolution. MSPathFinder searches the MS2 data against protein sequence databases with user-defined modifications. LcMsSpectator presents the results from ProMex and MSPathFinder in a format that allows quick manual evaluation of critical attributes for high-confidence identifications. When complemented with the open-modification tool TopPIC, this workflow enabled identification of novel histone PTMs including tyrosine bromination on histone H4 and H2A, H3 glutathionylation, and mapping of conventional PTMs along the entire protein for many histone subunits.

  5. High resolution spectrometry: how the analyzer and spectrometer performances and the beam emittance contribute to the results obtained

    International Nuclear Information System (INIS)

    Roussel, P.

    1984-01-01

    Using first order calculations derived for an achromatic system A) (deltaxsub(F)/deltaEsub(i)=0) or an optimised system O) (xsub(F) minima). It is shown that the final resolution measured in the local plane of the spectrometer depends only on the emittance of the accelerator and of the efficient area of the analyser exclusive of the properties of the spectrometer. The use of this result is only limited by higher order terms in the calculation or considerations out of this scope like target effects etc.. [fr

  6. Chlorinated paraffin analysis by gas chromatography Orbitrap high-resolution mass spectrometry: Method performance, investigation of possible interferences and analysis of fish samples.

    Science.gov (United States)

    Krätschmer, Kerstin; Cojocariu, Cristian; Schächtele, Alexander; Malisch, Rainer; Vetter, Walter

    2018-03-02

    For decades, high quantities of short-chain chlorinated paraffins (SCCP) and medium-chain chlorinated paraffins (MCCP) have been widely used, for instance as plasticizers or flame retardants, leading to global pollution due to unintentional emissions from products or waste. Due to the high complexity of chlorinated paraffins with several thousand congeners there is no consensus on an analytical procedure for SCCPs and MCCPs in food samples. Amongst the multitude of methods currently in use, high-resolution mass spectrometry is particularly valuable for in-depth studies of homologue patterns. Here we analyse SCCPs and MCCPs with gas chromatography coupled to high-resolution Orbitrap mass spectrometry (GC-Orbitrap-HRMS) operated in full-scan acquisition in electron capture negative ion (ECNI) mode at 60,000 and 120,000 resolution (FWHM, m/z 200, equals roughly 30,000 and 60,000 at 5% peak height). Linear dynamic range, selectivity and sensitivity tests confirmed an excellent linearity in a concentration range of 25-15,000 pg/μL with very low limits of detection (LODs) in the low pg/μL range. Spiking experiments with high levels of native mono- and di-ortho-polychlorinated biphenyls (PCBs) and mixtures of MCCP and SCCP standards did not have a negative impact on isotope ratios of the examined homologues. Besides the [M-Cl] - fragment ions used for quantification, the mass spectra of homologues also featured [M-HCl] - ions whose abundance increased with decreasing chlorination degree. In addition, [M-HCl-Cl] - ions were detected with a relative abundance of 5-10%. Three salmon (Salmo salar) samples farmed in Norway showed a consistent CP homologue pattern which differed both from the CP pattern in a sample from Scottish aquaculture and a wild salmon sample. These measurements produce evidence that discretely different CP patterns may exist in different areas of origin. Our results demonstrate that GC/ECNI-Orbitrap-HRMS is well-suited for the analysis of CPs by

  7. Accurate and precise 40Ar/39Ar dating by high-resolution, multi-collection, mass spectrometry

    DEFF Research Database (Denmark)

    Storey, Michael; Rivera, Tiffany; Flude, Stephanie

    New generation, high resolution, multi-collector noble gas mass spectrometers equipped with ion-counting electron multipliers provide opportunities for improved accuracy and precision in 40Ar/39Ar dating. Here we report analytical protocols and age cross-calibration studies using a NU-Instruments......New generation, high resolution, multi-collector noble gas mass spectrometers equipped with ion-counting electron multipliers provide opportunities for improved accuracy and precision in 40Ar/39Ar dating. Here we report analytical protocols and age cross-calibration studies using a NU......-Instruments multi-collector Noblesse noble gas mass spectrometer configured with a faraday detector and three ion-counting electron multipliers. The instrument has the capability to measure several noble gas isotopes simultaneously and to change measurement configurations instantaneously by the use of QUAD lenses...... (zoom optics). The Noblesse offer several advantages over previous generation noble gas mass spectrometers and is particularly suited for single crystal 40Ar/39Ar dating because of: (i) improved source sensitivity (ii) ion-counting electron multipliers, which have much lower signal to noise ratios than...

  8. Bioconversion of red ginseng saponins in the gastro-intestinal tract in vitro model studied by high-performance liquid chromatography-high resolution Fourier transform ion cyclotron resonance mass spectrometry

    NARCIS (Netherlands)

    Kong, H.; Wang, M.; Venema, K.; Maathuis, A.; Heijden, R. van der; Greef, J. van der; Xu, G.; Hankemeier, T.

    2009-01-01

    A high-performance liquid chromatography-high resolution Fourier transform ion cyclotron resonance mass spectrometry (HPLC-FTICR-MS) method was developed to investigate the metabolism of ginsenosides in in vitro models of the gastro-intestinal tract. The metabolites were identified by

  9. Flux Analysis of Free Amino Sugars and Amino Acids in Soils by Isotope Tracing with a Novel Liquid Chromatography/High Resolution Mass Spectrometry Platform.

    Science.gov (United States)

    Hu, Yuntao; Zheng, Qing; Wanek, Wolfgang

    2017-09-05

    Soil fluxomics analysis can provide pivotal information for understanding soil biochemical pathways and their regulation, but direct measurement methods are rare. Here, we describe an approach to measure soil extracellular metabolite (amino sugar and amino acid) concentrations and fluxes based on a 15 N isotope pool dilution technique via liquid chromatography and high-resolution mass spectrometry. We produced commercially unavailable 15 N and 13 C labeled amino sugars and amino acids by hydrolyzing peptidoglycan isolated from isotopically labeled bacterial biomass and used them as tracers ( 15 N) and internal standards ( 13 C). High-resolution (Orbitrap Exactive) MS with a resolution of 50 000 allowed us to separate different stable isotope labeled analogues across a large range of metabolites. The utilization of 13 C internal standards greatly improved the accuracy and reliability of absolute quantification. We successfully applied this method to two types of soils and quantified the extracellular gross fluxes of 2 amino sugars, 18 amino acids, and 4 amino acid enantiomers. Compared to the influx and efflux rates of most amino acids, similar ones were found for glucosamine, indicating that this amino sugar is released through peptidoglycan and chitin decomposition and serves as an important nitrogen source for soil microorganisms. d-Alanine and d-glutamic acid derived from peptidoglycan decomposition exhibited similar turnover rates as their l-enantiomers. This novel approach offers new strategies to advance our understanding of the production and transformation pathways of soil organic N metabolites, including the unknown contributions of peptidoglycan and chitin decomposition to soil organic N cycling.

  10. Flux Analysis of Free Amino Sugars and Amino Acids in Soils by Isotope Tracing with a Novel Liquid Chromatography/High Resolution Mass Spectrometry Platform

    Science.gov (United States)

    2017-01-01

    Soil fluxomics analysis can provide pivotal information for understanding soil biochemical pathways and their regulation, but direct measurement methods are rare. Here, we describe an approach to measure soil extracellular metabolite (amino sugar and amino acid) concentrations and fluxes based on a 15N isotope pool dilution technique via liquid chromatography and high-resolution mass spectrometry. We produced commercially unavailable 15N and 13C labeled amino sugars and amino acids by hydrolyzing peptidoglycan isolated from isotopically labeled bacterial biomass and used them as tracers (15N) and internal standards (13C). High-resolution (Orbitrap Exactive) MS with a resolution of 50 000 allowed us to separate different stable isotope labeled analogues across a large range of metabolites. The utilization of 13C internal standards greatly improved the accuracy and reliability of absolute quantification. We successfully applied this method to two types of soils and quantified the extracellular gross fluxes of 2 amino sugars, 18 amino acids, and 4 amino acid enantiomers. Compared to the influx and efflux rates of most amino acids, similar ones were found for glucosamine, indicating that this amino sugar is released through peptidoglycan and chitin decomposition and serves as an important nitrogen source for soil microorganisms. d-Alanine and d-glutamic acid derived from peptidoglycan decomposition exhibited similar turnover rates as their l-enantiomers. This novel approach offers new strategies to advance our understanding of the production and transformation pathways of soil organic N metabolites, including the unknown contributions of peptidoglycan and chitin decomposition to soil organic N cycling. PMID:28776982

  11. Rapid Classification and Identification of Multiple Microorganisms with Accurate Statistical Significance via High-Resolution Tandem Mass Spectrometry.

    Science.gov (United States)

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y; Drake, Steven K; Gucek, Marjan; Sacks, David B; Yu, Yi-Kuo

    2018-06-05

    Rapid and accurate identification and classification of microorganisms is of paramount importance to public health and safety. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is complicating correct microbial identification even in a simple sample due to the large number of candidates present. To properly untwine candidate microbes in samples containing one or more microbes, one needs to go beyond apparent morphology or simple "fingerprinting"; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptide-centric representations of microbes to better separate them and by augmenting our earlier analysis method that yields accurate statistical significance. Here, we present an updated analysis workflow that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using 226 MS/MS publicly available data files (each containing from 2500 to nearly 100,000 MS/MS spectra) and 4000 additional MS/MS data files, that the updated workflow can correctly identify multiple microbes at the genus and often the species level for samples containing more than one microbe. We have also shown that the proposed workflow computes accurate statistical significances, i.e., E values for identified peptides and unified E values for identified microbes. Our updated analysis workflow MiCId, a freely available software for Microorganism Classification and Identification, is available for download at https://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html . Graphical Abstract ᅟ.

  12. Normalization to specific gravity prior to analysis improves information recovery from high resolution mass spectrometry metabolomic profiles of human urine.

    Science.gov (United States)

    Edmands, William M B; Ferrari, Pietro; Scalbert, Augustin

    2014-11-04

    Extraction of meaningful biological information from urinary metabolomic profiles obtained by liquid-chromatography coupled to mass spectrometry (MS) necessitates the control of unwanted sources of variability associated with large differences in urine sample concentrations. Different methods of normalization either before analysis (preacquisition normalization) through dilution of urine samples to the lowest specific gravity measured by refractometry, or after analysis (postacquisition normalization) to urine volume, specific gravity and median fold change are compared for their capacity to recover lead metabolites for a potential future use as dietary biomarkers. Twenty-four urine samples of 19 subjects from the European Prospective Investigation into Cancer and nutrition (EPIC) cohort were selected based on their high and low/nonconsumption of six polyphenol-rich foods as assessed with a 24 h dietary recall. MS features selected on the basis of minimum discriminant selection criteria were related to each dietary item by means of orthogonal partial least-squares discriminant analysis models. Normalization methods ranked in the following decreasing order when comparing the number of total discriminant MS features recovered to that obtained in the absence of normalization: preacquisition normalization to specific gravity (4.2-fold), postacquisition normalization to specific gravity (2.3-fold), postacquisition median fold change normalization (1.8-fold increase), postacquisition normalization to urinary volume (0.79-fold). A preventative preacquisition normalization based on urine specific gravity was found to be superior to all curative postacquisition normalization methods tested for discovery of MS features discriminant of dietary intake in these urinary metabolomic datasets.

  13. Development of a high energy resolution magnetic bolometer for the determination of photon emission intensities by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Rodrigues, M.

    2007-12-01

    In this research thesis, a first chapter describes the metrological difficulties for the determination of radionuclide photon emission intensities. Then, it discusses the understanding and the required tools for the computing of a magnetic bolometer signal with respect to the different operation parameters and to the sensor geometry. The author describes the implementation of the experimental device and its validation with a first sensor. The new sensor is then optimised for the measurement of photon emission intensities with a good efficiency and a theoretical energy resolution less than 100 eV up to 200 keV. The sensor's detection efficiency and operation have been characterized with a 133 Ba source. The author finally presents the obtained results

  14. Quantitative Isotope-Dilution High-Resolution-Mass-Spectrometry Analysis of Multiple Intracellular Metabolites in Clostridium autoethanogenum with Uniformly 13C-Labeled Standards Derived from Spirulina.

    Science.gov (United States)

    Schatschneider, Sarah; Abdelrazig, Salah; Safo, Laudina; Henstra, Anne M; Millat, Thomas; Kim, Dong-Hyun; Winzer, Klaus; Minton, Nigel P; Barrett, David A

    2018-04-03

    We have investigated the applicability of commercially available lyophilized spirulina ( Arthrospira platensis), a microorganism uniformly labeled with 13 C, as a readily accessible source of multiple 13 C-labeled metabolites suitable as internal standards for the quantitative determination of intracellular bacterial metabolites. Metabolites of interest were analyzed by hydrophilic-interaction liquid chromatography coupled with high-resolution mass spectrometry. Multiple internal standards obtained from uniformly (U)- 13 C-labeled extracts from spirulina were used to enable isotope-dilution mass spectrometry (IDMS) in the identification and quantification of intracellular metabolites. Extraction of the intracellular metabolites of Clostridium autoethanogenum using 2:1:1 chloroform/methanol/water was found to be the optimal method in comparison with freeze-thaw, homogenization, and sonication methods. The limits of quantification were ≤1 μM with excellent linearity for all of the calibration curves ( R 2 ≥ 0.99) for 74 metabolites. The precision and accuracy were found to be within relative standard deviations (RSDs) of 15% for 49 of the metabolites and within RSDs of 20% for all of the metabolites. The method was applied to study the effects of feeding different levels of carbon monoxide (as a carbon source) on the central metabolism and Wood-Ljungdahl pathway of C. autoethanogenum grown in continuous culture over 35 days. Using LC-IDMS with U- 13 C spirulina allowed the successful quantification of 52 metabolites in the samples, including amino acids, carboxylic acids, sugar phosphates, purines, and pyrimidines. The method provided absolute quantitative data on intracellular metabolites that was suitable for computational modeling to understand and optimize the C. autoethanogenum metabolic pathways active in gas fermentation.

  15. A simple and fast method for assessment of the nitrogen–phosphorus–potassium rating of fertilizers using high-resolution continuum source atomic and molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bechlin, Marcos André; Fortunato, Felipe Manfroi; Moutinho da Silva, Ricardo; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta, E-mail: anchieta@iq.unesp.br

    2014-11-01

    The determination of N, P, and K in fertilizers by high-resolution continuum source flame atomic and molecular absorption spectrometry is proposed. Under optimized conditions, measurements of the diatomic molecules NO and PO at 215.360 and 247.620 nm, respectively, and K using the wing of the alternative line at 404.722 nm allowed calibration curves to be constructed in the ranges 500–5000 mg L{sup −1} N (r = 0.9994), 100–2000 mg L{sup −1} P (r = 0.9946), and 100–2500 mg L{sup −1} K (r = 0.9995). Commercial fertilizers were analyzed by the proposed method and the concentrations of N, P, and K were found to be in agreement with those obtained by Kjeldahl, spectrophotometric, and flame atomic emission spectrometry methods, respectively, at a 95% confidence level (paired t-test). A phosphate rock certified reference material (CRM) was analyzed and the results for P and K were in agreement with the reference values. Recoveries from spiked CRM were in the ranges 97–105% (NO{sub 3}{sup −}-N), 95–103% (NH{sub 4}{sup +}-N), 93–103% (urea-N), 99–108% (P), and 99–102% (K). The relative standard deviations (n = 12) for N, P, and K were 6, 4, and 2%, respectively. - Highlights: • A single technique is proposed to analyze NPK fertilizer. • HR-CS FAAS is proposed for the first time for N, P and K determination in fertilizers. • The method employs the same sample preparation and dilution for the three analytes. • Addition of H{sub 2}O{sub 2} allows analysis of fertilizers with different nitrogen species. • Proposal provides advantages over traditional methods in terms of cost and time.

  16. Validation of {sup 226}Ra, {sup 228}Ra and {sup 210}Pb measurements in soil and sediment samples through high resolution gamma ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Danila Carrijo da Silva; Silva, Nivaldo Carlos da; Bonifacio, Rodrigo Leandro; Guerrero, Eder Tadeu Zenun [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2013-07-01

    Radionuclides found in ore extraction waste materials are a great source of concern regarding public health and environmental safety. One technique to determine the concentration of substances is high resolution gamma ray spectrometry using HPGe. Validating a measurement technique is essential to warrant high levels of quality to any scientific work. The Laboratory of Pocos de Caldas of the Brazilian Commission for Nuclear Energy partakes into a Quality Management System project, seeking Accreditation under ISO/IEC 17025 through the validation of techniques of chemical and radiometric analysis of environmental samples from water, soil and sediment. The focus of the Radon Laboratory at LAPOC is validation of Ra-226, Ra-228 and Pb-210 concentration determinations in soil and sediment through a gamma spectrometer system. The stages of this validation process included sample reception and preparation, detector calibration and sample analyses. Dried samples were sealed in metallic containers and analyzed after radioactive equilibrium between Ra-226 and daughters Pb-214 and Bi-214. Gamma spectrometry was performed using CANBERRA HPGe detector and gamma spectrum software Genie 2000. The photo peaks used for Ra-226 determination were 609 keV and 1020 keV of Bi-214 and 351 keV of Pb-214. For the Ra-228 determination a photopeak of 911 keV was used from its short half-life daughter Ac-228 (T1/2 = 6.12 h). For Pb-210, the photopeak of 46.5 keV was used, which, due to the low energy, self-absorption correction was needed. Parameters such as precision, bias/accuracy, linearity, detection limit and uncertainty were evaluated for that purpose. The results have pointed to satisfying results. (author)

  17. CHARACTERIZATION OF ENALAPRIL AND RANITIDINE CHLORINATION BY-PRODUCTS BY LIQUID CHROMATOGRAPHY/HIGH-RESOLUTION MASS SPECTROMETRY AND THEIR TOXICITY EVALUATION

    Directory of Open Access Journals (Sweden)

    Frederico Jehár Oliveira Quintão

    Full Text Available Due to its low cost, its capability for disinfection and oxidation, chlorination using gaseous chlorine or hypochlorite salts, has also been commonly applied in water treatment plants for oxidation and disinfection purposes. Little is known about the identity and toxicity of by-products resulting from the chlorination of pharmaceutical micropollutants, such as enalapril (ENA and ranitidine (RAN. ENA and RAN chlorination by-products were characterized in this study by high-performance liquid chromatography coupled to high-resolution mass spectrometry (HPLC/HRMS and their toxicity were assessed by MTT assay. Chlorination experiments with ENA and RAN solutions (10 mg L-1 indicate degradation efficiencies of 100% for both compounds after only 5 min of exposure to chlorine at concentration of 9.53 mg Cl2 L-1. On the other hand mineralization rates were lower than 3%, thereby indicating there was accumulation of degradation by-products in all experiments. Mass spectrometric analysis revealed, at all times of reaction after the addition of hypochlorite, the presence of 1-(2-((4-(chlorophenyl-1-ethoxy-1-oxobutan-2-ylaminopropanoylpyrrolidine-2-carboxylic acid (enalapril by-product and N-chloro-N-(2-(((chloro-5-((dimethylaminomethylfuran-2-ylmethylsulfinylethyl-N-methyl-2-nitroethene 1,1-diamine (ranitidine by-product. Despite the formation of oxidized chlorinated by-products in all chlorination assays, the treated solutions were nontoxic to HepG2 cells by the MTT assay. It has been observed that chlorination (10 mg L-1, 5 min of ENA and RAN solutions exhibited high degradation efficiencies of the target compounds and low mineralization rates. Based on the mass spectrometry data, the routes for ENA and RAN successive oxidation by chlorine has been proposed.

  18. A simple and fast method for assessment of the nitrogen–phosphorus–potassium rating of fertilizers using high-resolution continuum source atomic and molecular absorption spectrometry

    International Nuclear Information System (INIS)

    Bechlin, Marcos André; Fortunato, Felipe Manfroi; Moutinho da Silva, Ricardo; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta

    2014-01-01

    The determination of N, P, and K in fertilizers by high-resolution continuum source flame atomic and molecular absorption spectrometry is proposed. Under optimized conditions, measurements of the diatomic molecules NO and PO at 215.360 and 247.620 nm, respectively, and K using the wing of the alternative line at 404.722 nm allowed calibration curves to be constructed in the ranges 500–5000 mg L −1 N (r = 0.9994), 100–2000 mg L −1 P (r = 0.9946), and 100–2500 mg L −1 K (r = 0.9995). Commercial fertilizers were analyzed by the proposed method and the concentrations of N, P, and K were found to be in agreement with those obtained by Kjeldahl, spectrophotometric, and flame atomic emission spectrometry methods, respectively, at a 95% confidence level (paired t-test). A phosphate rock certified reference material (CRM) was analyzed and the results for P and K were in agreement with the reference values. Recoveries from spiked CRM were in the ranges 97–105% (NO 3 − -N), 95–103% (NH 4 + -N), 93–103% (urea-N), 99–108% (P), and 99–102% (K). The relative standard deviations (n = 12) for N, P, and K were 6, 4, and 2%, respectively. - Highlights: • A single technique is proposed to analyze NPK fertilizer. • HR-CS FAAS is proposed for the first time for N, P and K determination in fertilizers. • The method employs the same sample preparation and dilution for the three analytes. • Addition of H 2 O 2 allows analysis of fertilizers with different nitrogen species. • Proposal provides advantages over traditional methods in terms of cost and time

  19. Validation of 226Ra, 228Ra and 210Pb measurements in soil and sediment samples through high resolution gamma ray spectrometry

    International Nuclear Information System (INIS)

    Dias, Danila Carrijo da Silva; Silva, Nivaldo Carlos da; Bonifacio, Rodrigo Leandro; Guerrero, Eder Tadeu Zenun

    2013-01-01

    Radionuclides found in ore extraction waste materials are a great source of concern regarding public health and environmental safety. One technique to determine the concentration of substances is high resolution gamma ray spectrometry using HPGe. Validating a measurement technique is essential to warrant high levels of quality to any scientific work. The Laboratory of Pocos de Caldas of the Brazilian Commission for Nuclear Energy partakes into a Quality Management System project, seeking Accreditation under ISO/IEC 17025 through the validation of techniques of chemical and radiometric analysis of environmental samples from water, soil and sediment. The focus of the Radon Laboratory at LAPOC is validation of Ra-226, Ra-228 and Pb-210 concentration determinations in soil and sediment through a gamma spectrometer system. The stages of this validation process included sample reception and preparation, detector calibration and sample analyses. Dried samples were sealed in metallic containers and analyzed after radioactive equilibrium between Ra-226 and daughters Pb-214 and Bi-214. Gamma spectrometry was performed using CANBERRA HPGe detector and gamma spectrum software Genie 2000. The photo peaks used for Ra-226 determination were 609 keV and 1020 keV of Bi-214 and 351 keV of Pb-214. For the Ra-228 determination a photopeak of 911 keV was used from its short half-life daughter Ac-228 (T1/2 = 6.12 h). For Pb-210, the photopeak of 46.5 keV was used, which, due to the low energy, self-absorption correction was needed. Parameters such as precision, bias/accuracy, linearity, detection limit and uncertainty were evaluated for that purpose. The results have pointed to satisfying results. (author)

  20. Ultra-high performance supercritical fluid chromatography hyphenated to atmospheric pressure chemical ionization high resolution mass spectrometry for the characterization of fast pyrolysis bio-oils.

    Science.gov (United States)

    Crepier, Julien; Le Masle, Agnès; Charon, Nadège; Albrieux, Florian; Duchene, Pascal; Heinisch, Sabine

    2018-06-01

    Extensive characterization of complex mixtures requires the combination of powerful analytical techniques. A Supercritical Fluid Chromatography (SFC) method was previously developed, for the specific case of fast pyrolysis bio oils, as an alternative to gas chromatography (GC and GC × GC) or liquid chromatography (LC and LC × LC), both separation methods being generally used prior to mass spectrometry (MS) for the characterization of such complex matrices. In this study we investigated the potential of SFC hyphenated to high resolution mass spectrometry (SFC-HRMS) for this characterization using Negative ion Atmospheric Pressure Chemical ionization ((-)APCI) for the ionization source. The interface between SFC and (-)APCI/HRMS was optimized from a mix of model compounds with the objective of maximizing the signal to noise ratio. The main studied parameters included both make-up flow-rate and make-up composition. A methodology for the treatment of APCI/HRMS data is proposed. This latter allowed for the identification of molecular formulae. Both SFC-APCI/HRMS method and data processing method were applied to a mixture of 36 model compounds, first analyzed alone and then spiked in a bio-oil. In both cases, 19 compounds could be detected. Among them 9 could be detected in a fast pyrolysis bio-oil by targeted analysis. The whole procedure was applied to the characterization of a bio-oil using helpful representations such as mass-plots, van Krevelen diagrams and heteroatom class distributions. Finally the results were compared with those obtained with a Fourier Transform ion-cyclotron resonance mass spectrometer (FT-ICR/MS). Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Measuring the hydrogen/deuterium exchange of proteins at high spatial resolution by mass spectrometry: overcoming gas-phase hydrogen/deuterium scrambling.

    Science.gov (United States)

    Rand, Kasper D; Zehl, Martin; Jørgensen, Thomas J D

    2014-10-21

    Proteins are dynamic molecules that exhibit conformational flexibility to function properly. Well-known examples of this are allosteric regulation of protein activity and ligand-induced conformational changes in protein receptors. Detailed knowledge of the conformational properties of proteins is therefore pertinent to both basic and applied research, including drug development, since the majority of drugs target protein receptors and a growing number of drugs introduced to the market are therapeutic peptides or proteins. X-ray crystallography provides a static picture at atomic resolution of the lowest-energy structure of the native ensemble. There is a growing need for sensitive analytical tools to explore all of the significant molecular structures in the conformational landscape of proteins. Hydrogen/deuterium exchange monitored by mass spectrometry (HDX-MS) has recently emerged as a powerful method for characterizing protein conformational dynamics. The basis of this method is the fact that backbone amides in stable hydrogen-bonded structures (e.g., α-helices and β-sheets) are protected against exchange with the aqueous solvent. All protein structures are dynamic, however, and eventually all of the protecting hydrogen bonds will transiently break as the protein--according to thermodynamic principles--cycles through partially unfolded states that correspond to excited free energy levels. As a result, all of the backbone amides will eventually become temporarily solvent-exposed and exchange-competent over time. Consequently, a folded protein in D2O will gradually incorporate deuterium into its backbone amides, and the kinetics of the process can be readily monitored by mass spectrometry. The deuterium uptake kinetics for the intact protein (global exchange kinetics) represents the sum of the exchange kinetics for the individual backbone amides. Local exchange kinetics is typically achieved by using pepsin digestion under quench conditions (i.e., under cold

  2. Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine.

    Science.gov (United States)

    Cha, Eunju; Jeong, Eun Sook; Cha, Sangwon; Lee, Jaeick

    2017-04-29

    In this study, gas chromatography (GC) was interfaced with high resolution mass spectrometry (HRMS) with electrospray ionization source (ESI) and the relevant parameters were investigated to enhance the ionization efficiency. In GC-ESI, the distances (x-, y- and z) and angle between the ESI needle, GC capillary column and MS orifice were set to 7 (x-distance), 4 (y-distance), and 1 mm (z-distance). The ESI spray solvent, acid modifier and nebulizer gas flow were methanol, 0.1% formic acid and 5 arbitrary units, respectively. Based on these results, analytical conditions for GC-ESI/HRMS were established. In particular, the results of spray solvent flow indicated a concentration-dependent mechanism (peak dilution effect), and other parameters also greatly influenced the ionization performance. The developed GC-ESI/HRMS was then applied to the analysis of anabolic steroids as trimethylsilyl (TMS) derivatives in human urine to demonstrate its application. The ionization profiles of TMS-derivatized steroids were investigated and compared with those of underivatized steroids obtained from gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) and liquid chromatography-electrospray ionization/mass spectrometry (LC-ESI/MS). The steroids exhibited ionization profiles based on their structural characteristics, regardless of the analyte phase or derivatization. Groups I and II with conjugated or unconjugated keto functional groups at C3 generated the [M+H] + and [M+H-TMS] + ions, respectively. On the other hand, Groups III and IV gave rise to the characteristic fragment ions [M+H-TMS-H 2 O] + and [M+H-2TMS-H 2 O] + , corresponding to loss of a neutral TMS·H 2 O moiety from the protonated molecular ion by in-source dissociation. To the best of our knowledge, this is the first study to successfully ionize and analyze steroids as TMS derivatives using ESI coupled with GC. The present system has enabled the ionization of TMS derivatives under ESI conditions

  3. Detection of anabolic and androgenic steroids and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Kwok, Karen Y; Choi, Timmy L