WorldWideScience

Sample records for resin titration rt

  1. Quantitative RT-PCR for titration of replication-defective recombinant Semliki Forest virus.

    Science.gov (United States)

    Puglia, Ana L P; Rezende, Alexandre G; Jorge, Soraia A C; Wagner, Renaud; Pereira, Carlos A; Astray, Renato M

    2013-11-01

    Virus titration may constitute a drawback in the development and use of replication-defective viral vectors like Semliki Forest virus (SFV). The standardization and validation of a reverse transcription quantitative PCR (qRT-PCR) method for SFV titration is presented here. The qRT-PCR target is located within the nsp1 gene of the non-structural polyprotein SFV region (SFV RNA), which allows the strategy to be used for several different recombinant SFV constructs. Titer determinations were carried out by performing virus titration and infection assays with SFVs containing an RNA coding region for the rabies virus glycoprotein (RVGP) or green fluorescent protein (GFP). Results showed that the standardized qRT-PCR is applicable for different SFV constructs, and showed good reproducibility. To evaluate the correlation between the amount of functional SFV RNA in a virus lot and its infectivity in BHK-21 cell cultures, a temperature mediated titer decrease was performed and successfully quantitated by qRT-PCR. When used for cell infection at the same multiplicity of infection (MOI), the temperature treated SFV-RVGP samples induced the same levels of RVGP expression. Similarly, when different SFV-GFP lots with different virus titers, as accessed by qRT-PCR, were used for cell infection at the same MOI, the cultures showed comparable amounts of fluorescent cells. The data demonstrate a good correlation between the amount of virus used for infection, as measured by its SFV RNA, and the protein synthesis in the cells. In conclusion, the qRT-PCR method developed here is accurate and enables the titration of replication-defective SFV vectors, an essential aid for viral vector development as well as for establishment of production bioprocesses. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Isothermal Titration Calorimetry and Fluorescence Spectroscopy Study Of Asphaltene Self-Association In Toluene And Interaction With A Model Resin

    DEFF Research Database (Denmark)

    Garcia, Daniel Merino; Andersen, Simon Ivar

    2002-01-01

    This article collects the work performed by Isothermal Titration Caloritnetry (ITC) in the study of the self-association of asphaltenes in toluene solutions. Calorimetric experiments show that asphaltenes, start self-associating at very low concentrations and that the existence of a Critical...... with the results of the titration of three model molecules: nonylphenol, which associates by means of hydrogen bond formation, and coronene and pyrene, which associates by stacking. The results obtained leave open the question about the model-stacking molecules, as it was not possible to elucidate whether they do...

  3. base titration

    African Journals Online (AJOL)

    The pH and temperature in the titration cell were monitored using single junction electrodes and platinum resistance thermometers, respectively. A constant supply of nitrogen gas in the cell was used to maintain inert conditions. The whole set up was interfaced with a computer for easy data acquisition. It was observed that ...

  4. Automated uranium titration system

    International Nuclear Information System (INIS)

    Takahashi, M.; Kato, Y.

    1983-01-01

    An automated titration system based on the Davies-Gray method has been developed for accurate determination of uranium. The system consists of a potentiometric titrator with precise burettes, a sample changer, an electronic balance and a desk-top computer with a printer. Fifty-five titration vessels are loaded in the sample changer. The first three contain the standard solution for standardizing potassium dichromate titrant, and the next two and the last two contain the control samples for data quality assurance. The other forty-eight measurements are carried out for sixteen unknown samples. Sample solution containing about 100 mg uranium is taken in a titration vessel. At the pretreatment position, uranium (VI) is reduced to uranium (IV) by iron (II). After the valency adjustment, the vessel is transferred to the titration position. The rate of titrant addition is automatically controlled to be slower near the end-point. The last figure (0.01 mL) of the equivalent titrant volume for uranium is calculated from the potential change. The results obtained with this system on 100 mg uranium gave a precision of 0.2% (RSD,n=3) and an accuracy of better than 0.1%. Fifty-five titrations are accomplished in 10 hours. (author)

  5. Filtrates & Residues: Olfactory Titration.

    Science.gov (United States)

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  6. ''Titration'' polymerization of monovinylacetylene

    NARCIS (Netherlands)

    Mavinkurve, A; Visser, S; vandenBroek, W; Pennings, AJ

    1996-01-01

    A polymer consisting of a saturated carbon backbone with pendent acetylenic groups was prepared from monovinylacetylene. A titration was performed between the monomer and tertiary butyllithium, its lithiating agent. The charge transfer complex formed between the solvent THF and the tertiary

  7. Titration Curves: Fact and Fiction.

    Science.gov (United States)

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  8. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  9. Potentiometric titration and equivalent weight of humic acid

    Science.gov (United States)

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  10. Tracer-monitored flow titrations.

    Science.gov (United States)

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Iodine losses during Winkler titrations

    Science.gov (United States)

    Knapp, George P.; Stalcup, Marvel C.; Stanley, Robert J.

    1991-01-01

    An experiment designed to measure iodine loss during the aliquot version of the Winkler titration for dissolved oxygen in seawater shows that 0.01-0.03 ml l -1 equivalent oxygen is lost at typical oceanic concentrations in the method presently used. A standardization technique, which mimics that employed during the titration of seawater samples, compensates for this iodine loss throughout the oceanic range. This result, contradicting an earlier report by GREEN and CARRITT (1966, Analyst, 91, 207-208), demonstrates that the whole-bottle method of oxygen titration is not to be preferred over the aliquot method.

  12. Amperometric, Bipotentiometric, and Coulometric Titration.

    Science.gov (United States)

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  13. Modified ion exchange resins - synthesis and properties. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Doescher, F.; Klein, J.; Pohl, F.; Widdecke, H.

    1982-01-22

    Sulfomethylated resins are prepared by polymer analogous reactions, starting from macroporous poly(styrene-co-divinylbenzene) matrices. Different reaction paths are discussed and used in the synthesis. Sulfomethylation can be achieved by reaction of a chloromethylated resin with dimethyl sulfide and sodium sulfonate or alternatively by oxidation of polymer-bound thiol groups. Both methods give high conversions as shown by IR spectra and titration of the sulfonic acid groups. Poly(1-(4-hydroxysulfomethylphenyl)ethylene) (3) is obtained by reaction of poly(1-(4-hydroxyphenyl)ethylene) (2) resin with formaldehyde/sodium sulfonate. The thermal stability, catalytic activity, and ion exchange equilibria of the sulfomethylated resin are investigated.

  14. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  15. Plastic casting resin poisoning

    Science.gov (United States)

    Epoxy poisoning; Resin poisoning ... Epoxy and resin can be poisonous if they are swallowed or their fumes are breathed in. ... Plastic casting resins are found in various plastic casting resin products.

  16. Colorblindness and Titrations with Visual Indicators.

    Science.gov (United States)

    Diehl, Harvey; And Others

    1985-01-01

    Discusses various issues related to colorblind students performing titrations with visual indicators. Includes tables showing precisions in the titration of a weak acid by colorblind students using phenolphthalein and thymolphthalein and in the titration of a weak base by colorblind persons using methyl red and bromcresol green. (JN)

  17. Resin composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Peutzfeldt, Anne; Lussi, Adrian

    2014-01-01

    OBJECTIVE: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity...... of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p....008). CONCLUSIONS: The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE: The results from this study suggest that the marginal quality of restorations can...

  18. Automated back titration method to measure phosphate

    International Nuclear Information System (INIS)

    Comer, J.; Tehrani, M.; Avdeef, A.; Ross, J. Jr.

    1987-01-01

    Phosphate was measured in soda drinks and as an additive in flour, by a back titration method in which phosphate was precipitated with lanthanum, and the excess lanthanum was titrated with fluoride. All measurements were performed using the Orion fluoride electrode and the Orion 960 Autochemistry System. In most commercial automatic titrators, the inflection point of the titration curve, calculated from the first derivative of the curve, is used to find the equivalence polar of the titration. The inflection technique is compared with a technique based on Gran functions, which uses data collected after the end point and predicts the equivalence point accordingly

  19. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  20. Automatic titrator for high precision plutonium assay

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.

    1986-01-01

    Highly precise assay of plutonium metal is required for accountability measurements. We have developed an automatic titrator for this determination which eliminates analyst bias and requires much less analyst time. The analyst is only required to enter sample data and start the titration. The automated instrument titrates the sample, locates the end point, and outputs the results as a paper tape printout. Precision of the titration is less than 0.03% relative standard deviation for a single determination at the 250-mg plutonium level. The titration time is less than 5 min

  1. Risks and Benefits of Rapid Clozapine Titration.

    Science.gov (United States)

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  2. Risks and benefits of rapid clozapine titration

    Directory of Open Access Journals (Sweden)

    Jeannie D. Lochhead

    2016-05-01

    Full Text Available Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  3. Review: Resin Composite Filling

    OpenAIRE

    Desmond Ng; Jimmy C. M. Hsiao; Keith C. T. Tong; Harry Kim; Yanjie Mai; Keith H. S. Chan

    2010-01-01

    The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin ...

  4. Contributions to the theory of catalytic titrations-III Neutralization catalytic titrations.

    Science.gov (United States)

    Gaál, F F; Abramović, B F

    1985-07-01

    Neutralization catalytic titrations of weak monoprotic adds and bases with both volumetric and coulometric addition of the titrant (strong base/acid) have been simulated by taking into account the equilibrium concentration of the catalyst during the titration. The influence of several factors on the shape of the simulated catalytic titration curve has been investigated and is discussed.

  5. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  6. Resin Characterization

    Science.gov (United States)

    2015-06-01

    to see plastic deformation of the surface. 8.1.4.3 Density: Density using the Archimedes principle (ASTM D 792). 8.1.4.4 Density as a Function of...the cure and postcure, quickly cool the sample to 0 °C or lower the temperature to quench the reaction, and then ramp the temperature at 5 °C/min to...prepared by pouring 10 g of resin into a 30-mL screw-cap scintillation vial and adding appropriate amounts of initiator, catalyst, and inhibitor

  7. A titration model for evaluating calcium hydroxide removal techniques

    Directory of Open Access Journals (Sweden)

    Mark PHILLIPS

    2015-02-01

    Full Text Available Objective Calcium hydroxide (Ca(OH2 has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH2 left after different endodontic irrigation methods. Material and Methods Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH2 followed by gross Ca(OH2 removal using hand files and randomized treatment of either: 1 Syringe irrigation; 2 Syringe irrigation with use of an apical file; 3 Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI, or 4 Syringe irrigation with apical file and PUI (n=12/group. Residual Ca(OH2 was dissolved with glycerin and titrated to measure residual Ca(OH2 left in the root. Results No method completely removed all residual Ca(OH2. The addition of 30 s PUI with or without apical file use removed Ca(OH2 significantly better than irrigation alone. Conclusions This technique allowed quantification of residual Ca(OH2. The use of PUI (with or without apical file resulted in significantly lower Ca(OH2 residue compared to irrigation alone.

  8. Green chemistry volumetric titration kit for pharmaceutical ...

    African Journals Online (AJOL)

    Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR), Ministry of Small Scale Industries, Government of India), developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and ...

  9. A Tabular Approach to Titration Calculations

    Science.gov (United States)

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  10. Virus isolation vs RT-PCR: which method is more successful in detecting VHSV and IHNV in fish tissue sampled under field conditions?

    DEFF Research Database (Denmark)

    Knüsel, R.; Bergmann, S. M.; Einer-Jensen, Katja

    2007-01-01

    in Switzerland. Compared to SPNT, the RT-PCR method detected, as with virus isolation, a much lower number of positive cases; reasons for this discrepancy are discussed. Our results indicate that RT-PCR can not only be successfully applied in field surveys, but may also be slightly more sensitive than virus...... isolation. However, in a titration experiment under laboratory conditions, the sensitivity of RT-PCR was not significantly higher when compared with virus isolation....

  11. Potentiometric Titration Method for Quantitative Determination of Hydrogen Peroxide

    National Research Council Canada - National Science Library

    Bessette, Russell R

    2005-01-01

    An electrochemical potentiometric titration method that entails titration of a known volume of a catholyte containing an unknown amount of hydrogen peroxide in a titration cell having two electrodes...

  12. Immobilization of spent resin with epoxy resin

    International Nuclear Information System (INIS)

    Gultom, O.; Suryanto; Sayogo; Ramdan

    1997-01-01

    immobilization of spent resin using epoxy resin has been conducted. The spent resin was mixtured with epoxy resin in variation of concentration, i.e., 30, 40, 50, 60, 70 weight percent of spent resin. The mixture were pour into the plastic tube, with a diameter of 40 mm and height of 40 mm. The density, compressive strength and leaching rate were respectively measured by quanta chrome, paul weber apparatus and gamma spectrometer. The results showed that the increasing of waste concentration would be decreased the compressive strength, and increased density by immobilized waste. The leaching rate of 137 Cs from waste product was not detected in experiment (author)

  13. Non-aqueous titration of hydroxamic acids.

    Science.gov (United States)

    Stamey, T W; Christian, R

    1966-01-01

    Benzohydroxamic acid is titrated with 0.1M tetrabutyl-anunonium hydroxide in nine non-aqueous solvents with three different indicating electrodes. The best results are obtained using dimethylformamide as solvent and platinum-platinum electrodes. Four monoprotic and three diprotic hydroxamie acids and iron(III) benzohydroxamate have been successfully titrated with this system. The effect of quantitative additions of carbon dioxide to the titrant on its apparent molarity are found to be dependent on the amount added, the strength and sample size of acid titrated and the solvent used.

  14. Complexometric titration of lanthanides and yttrium

    International Nuclear Information System (INIS)

    Ionashiro, M.; Graner, C.A.F.; Zuanon Netto, J.

    1983-01-01

    The pH variation of the solution and the ammonium acetate buffering were studied when different quantities of lanthanides and yttrium were titrated with EDTA, and xylenol orange as indicator. (Author) [pt

  15. Review: Resin Composite Filling

    Directory of Open Access Journals (Sweden)

    Desmond Ng

    2010-02-01

    Full Text Available The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin composite has aesthetic advantages over amalgam, one of the major disadvantage include polymerization shrinkage and future research is needed on reaction kinetics and viscoelastic behaviour to minimize shrinkage stress.

  16. Review: Resin Composite Filling

    Science.gov (United States)

    Chan, Keith H. S.; Mai, Yanjie; Kim, Harry; Tong, Keith C. T.; Ng, Desmond; Hsiao, Jimmy C. M.

    2010-01-01

    The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin composite has aesthetic advantages over amalgam, one of the major disadvantage include polymerization shrinkage and future research is needed on reaction kinetics and viscoelastic behaviour to minimize shrinkage stress.

  17. Theory of titration curves-VII The properties of derivative titration curves for strong acid-strong base and other isovalent ion-combination titrations.

    Science.gov (United States)

    Meites, T; Meites, L

    1970-06-01

    This paper deals with isovalent ion-combination titrations based on reactions that can be represented by the equation M(n+) + X(n-) --> MX, where the activity of the product MX is invariant throughout a titration, and with the derivative titration curves obtained by plotting d[M(+)]/dfversus f for such titrations. It describes some of the ways in which such curves can be obtained; it compares and contrasts them both with potentiometric titration curves, which resemble them in shape, and with segmented titration curves, from which they are derived; and it discusses their properties in detail.

  18. Synthesis and characterization of an N-(2-hydroxyethyl)-ethylenediaminetriacetic acid resin

    International Nuclear Information System (INIS)

    Lai, Y.F.

    1977-10-01

    A chelating ion-exchange resin with N-(2-hydroxyethyl)ethylene-diaminetriacetic acid (HEDTA) used as the ligand chemically bonded to XAD-4 by an ester linkage, HEDTA-4, was synthesized. It is stable under normal experimental conditions with the liquid chromatograph. The structure of the resin was confirmed by an infrared spectrum, and by potentiometric titrations. The capacity of the resin was also obtained by potentiometric titration and by a nitrogen analysis. The resin was used to pack a column of 5 mm internal diameter and 5 cm long. The effect of pH on the retention of different metal ions on the resin was studied. It was found that the resin was most selective for chromium(III), copper(II), lead(II), mercury(II), uranium(VI), zirconium(IV) and zinc(II) at a pH of less than 3. Furthermore, the resin proves to be functioning with a chelating mechanism rather than ion-exchange, and it can concentrate trace metal ions in the presence of a large excess of calcium and magnesium. This makes the resin potentially useful for purifying and analyzing drinking water

  19. Plutonium titration by controlled potential coulometry

    International Nuclear Information System (INIS)

    Leguay, N.

    2011-01-01

    The LAMMAN (Nuclear Materials Metrology Laboratory) is the support laboratory of the CETAMA (Analytical Method Committee), whose two main activities are developing analytic methods, and making and characterizing reference materials. The LAMMAN chose to develop the controlled potential coulometry because it is a very accurate analytical technique which allows the connection between the quantity of element electrolysed to the quantity of electricity measured thanks to the Faraday's law: it does not require the use of a chemical standard. This method was first used for the plutonium titration and was developed in the Materials Analysis and Metrology Laboratory (LAMM), for upgrading its performances and developing it to the titration of other actinides. The equipment and the material used were developed to allow the work in confined atmosphere (in a glove box), with all the restrictions involved. Plutonium standard solutions are used to qualify the method, and in particular to do titrations with an uncertainty better than 0.1 %. The present study allowed making a bibliographic research about controlled potential coulometry applied to the actinides (plutonium, uranium, neptunium, americium and curium). A full procedure was written to set all the steps of plutonium titration, from the preparation of samples to equipments storage. A method validation was done to check the full procedure, and the experimental conditions: working range, uncertainty, performance... Coulometric titration of the plutonium from pure solution (without interfering elements) was developed to the coulometric titration of the plutonium in presence of uranium, which allows to do accurate analyses for the analyses of some parts of the reprocessing of the spent nuclear fuel. The possibility of developing this method to other actinides than plutonium was highlighted thanks to voltammetric studies, like the coulometric titration of uranium with a working carbon electrode in sulphuric medium. (author)

  20. Coulometric titration at low temperatures-nonstoichiometric silver selenide

    OpenAIRE

    Beck, Gesa K.; Janek, Jürgen

    2003-01-01

    A modified coulometric titration technique is described for the investigation of nonstoichiometric phases at low temperatures. It allows to obtain titration curves at temperatures where the conventional coulometric titration technique fails because of too small chemical diffusion coefficients of the mobile component. This method for indirect coulometric titration is applied to silver selenide between -100 and 100 °C. The titration curves are analyzed on the basis of a defect chemical model an...

  1. End-point construction and systematic titration error in linear titration curves-complexation reactions

    NARCIS (Netherlands)

    Coenegracht, P.M.J.; Duisenberg, A.J.M.

    The systematic titration error which is introduced by the intersection of tangents to hyperbolic titration curves is discussed. The effects of the apparent (conditional) formation constant, of the concentration of the unknown component and of the ranges used for the end-point construction are

  2. Resin-Powder Dispenser

    Science.gov (United States)

    Standfield, Clarence E.

    1994-01-01

    Resin-powder dispenser used at NASA's Langley Research Center for processing of composite-material prepregs. Dispenser evenly distributes powder (resin polymer and other matrix materials in powder form) onto wet uncured prepregs. Provides versatility in distribution of solid resin in prepreg operation. Used wherever there is requirement for even, continuous distribution of small amount of powder.

  3. 40 CFR Appendix B to Subpart Nnn... - Free Formaldehyde Analysis of Insulation Resins by Hydroxylamine Hydrochloride

    Science.gov (United States)

    2010-07-01

    ... with a high FF content. 2. Principle 2.1a. The basis for this method is the titration of the...—Free Formaldehyde Analysis of Insulation Resins by Hydroxylamine Hydrochloride 1. Scope This method was... method. The sample should contain approximately 0.3 grams free formaldehyde to ensure complete reaction...

  4. An accurate potentiometric titration of 5-25 mg uranium

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Lingerak, W.A.

    1976-01-01

    A potentiometric titration of 5 to 25 mg uranium is described. Sulphamic and phosphoric acid are added to the sample (volume 1 ml), U VI is reduced to U IV by Fe 2+ and the excess of Fe 2+ is oxidized by a mixture of nitric acid, sulphamic acid and ammonium molybdate; vanadyl sulphate is added to ensure a sharp end-point of the titration. The resultant U IV is titrated automatically with 0.02500N potassiumdichromate using a platinum indicator electrode. The automatic titration is performed both with a commercial titrator (Mettler) and with an R.C.N. titrator which waits after each addition until the equilibrium is reached. Using the Mettler titrator an accuracy of 0.05% relative was reached. The R.C.N. setpoint titrator gave results with an accuracy of 0.04% relative at the 20-mg U level. Each titration takes 5 to 7 min. (author)

  5. Ion exchange resin fouling of molybdenum in recovery uranium processess

    International Nuclear Information System (INIS)

    Zhang Guowei; Zhao Guirong

    1990-09-01

    The relationship between anion exchange resin fouling and molybdic acid polymerization was studied. By using potentiometer titration and laser-Raman spectroscopy the relationship of molybdic acid polymerization and the pH value of solution or the molybdenum concentration was determined. It was shown that as the concentration of initial molybdenum in solution decreases from 0.2 mol/L to 0.5 mmol/L, the pH value of starting polymerization decreased from 6.5 to 4.5. The experimental results show that the fouling of 201 x 7 resin in the acidic solution is mainly caused by the adsorbing of Mo 3 O 26 4- ion and occupying the exchange radical site of the resin. Under the leaching conditions the molybdenum and phosphate existing in the leaching liquor can form 12-molybdo-phosphate ion. It also leads to resin fouling. The molybdenum on the fouled resin can synergically be desorbed by mixed desorbents containing ammonium hydroxide and ammonium sulfate. The desorbed resin can be used for uranium adsorption and the desorbed molybdenum can be recovered by ion exchange method

  6. AUTOMATION OF POTENTIOMETRIC TITRATION WITH A ...

    African Journals Online (AJOL)

    An IBM compatible interface card system with infrared source-detector data sampling was designed and tested for automation of potentiometric titrations with personal computers without continuous measurement of the volume of the titrant. The device with other appropriate apparatus and setup was tested for determination ...

  7. Titrated Misoprostol Versus Dinoprostone for Labor Induction

    African Journals Online (AJOL)

    . Studied women were randomized into; Group I: 104 women included and received oral 200 µg misoprostol in 200 ml water titrated over 12 h and Group II: 108 women included and received vaginal dinoprostone tablet (3 mg) maximum two ...

  8. Isothermal Titration Calorimetry in the Student Laboratory

    Science.gov (United States)

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  9. Titration Calculations with Computer Algebra Software

    Science.gov (United States)

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  10. NBL-Davies-Gray weight titration method

    International Nuclear Information System (INIS)

    Hassell, C.

    1981-01-01

    The titration method for uranium consists of the following basic steps: reduction of U +6 to U +4 by Fe +2 ; selective oxidation of excess Fe +2 by HNO 3 with Mo +6 catalyst, all in strong phosphoric acid solution; and titration of the U +4 with standard dichromate after dilution. In this paper, detailed procedure of the NBL method, its modification to a gravimetric system or weight titration technique, and miniaturization of the NBL titrimetric method are discussed. Improved precisions and accuracy (2 to 3 times), of the gravimetric titrant delivery has made it possible to reduce the amount of uranium taken for each analysis. At present, using gravimetric delivery, most samples are titrated in the 30 to 50 mg range. Improved precision has led to investigating the possibility of a scaled-down version of the basic method so as to reduce the volume of phosphoric acid waste generated. Because all reactions are carried out in the same vessel, this method can be automated. Analysts at NBL have been able to restrict error to 0.05% or better in the 30 to 100 mg range using the basic procedure

  11. Coulometric titration of ketotifen in tablets.

    Science.gov (United States)

    Ciesielski, W; Zakrzewski, R; Złobińska, U

    2005-03-01

    A method for the determination of ketotifen involving its reaction with iodine in an alkaline medium is presented. In coulometric titration using biamperometric end-point detection 0.25-2 micromol (77-618 microg) of ketotifen was successfully determined. The elaborated method was applied to the determination of ketotifen in drugs.

  12. An Olfactory Indicator for Acid-Base Titrations.

    Science.gov (United States)

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  13. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  14. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    Science.gov (United States)

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Potentiometric determination of milligram amounts of uranium by semiautomatic titrator

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Stepanov, A.V.; Preobrazhenskaya, L.D.; Solntseva, L.F.; Gromova, E.A.

    1978-01-01

    A semiautomatic titrator is described which allows gravimetriotentiometricc-p titrat mg amounts of substances. Milligram amounts of uranium (absolute contents and oxygen/uranium ratio) in U 3 O 8 were determined as an example of the titrator action. The relative standard deviation was less than 0.001

  16. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    Science.gov (United States)

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  17. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    Science.gov (United States)

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  18. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  19. Kinetic Titration Series with Biolayer Interferometry

    Science.gov (United States)

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  20. Coulometrische titration von hypochloriten und chloraten.

    Science.gov (United States)

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  1. Spectrophotometric titration of zirconium in siliceous materials

    International Nuclear Information System (INIS)

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  2. Determination of milligram amounts of neptunium by potentiometric titration

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Solntseva, L.F.

    1981-01-01

    Two procedures of potentiometric titration of about 1 mg Np are reported which are based on its oxidation to neptunium (6) with silver (2) oxide followed by titration with iron (2) to neptunium (5) in one case and to neptunium (4) in the alternative one. The error is not greater than 0.2% rel. Ten-fold uranium excess does not interfere. Up to 1% of plutonium relative to neptunium does not interfere in the case of the titration to neptunium (5). In the titration to neptunium (4), plutonium is titrated stoichiometrically [ru

  3. A new sensor for thermometric titrations.

    Science.gov (United States)

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  4. A monosegmented-flow Karl Fischer titrator.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2007-02-28

    A monosegmented volumetric Karl Fischer titrator is described to mechanize the determination of water content in organic solvents. The system is based on the flow-batch characteristics of the monosegmented analysis concept and employs biamperometry to monitor the progress of the titration. The system shows accuracy and precision that are highly independent of the flow rate, does not require calibration, and is carried out in a closed system capable of minimizing contact of the sample and reagents with ambient moisture. Sample volumes in the range of 40-300muL are employed, depending on the water concentration. An automatic dilution is provided to deal with concentrated samples. The consumption of Karl Fischer reagent depends on the water content of the sample but is not larger than 100muL. The system was evaluated for determination of water in ethanol and methanol in the range 0.02-0.5% (w/w). The average relative precision estimated in that range (9-3%) is comparable to that obtained with a larger volume commercial system and no significant difference was observed between the results obtained for the two systems at the 95% confidence level. A complete titration can be performed in less than 5min employing the proposed system.

  5. Potentiometric titrations in anhydrous acetic acid

    International Nuclear Information System (INIS)

    Le Port, L.

    1966-03-01

    The method used for studying anhydrous acetic acid is potentiometry with a glass electrode. We have in this way studied the titration of common inorganic acids (HClO 4 - HBr - H 2 SO 4 - HCl - HNO 3 - H 3 PO 4 ) and of some metallic salts. Furthermore we have shown that complex acids are formed between HCl and some metallic chlorides. An analysis of the titration curves for the inorganic acids against pyridinium chloride has made it possible to calculate a certain number of values for the dissociation pK of these acids and of the corresponding pyridinium salts. The titration of metallic perchlorates constitutes a method of studying the stability of acetates; we have thus been able to draw up a classification for some of these acetates. The metallic chlorides studied fall into two groups according to their behaviour in weak or strong acids. The differences have been explained on the basis of the role played by solvolysis. In the third part we have studied the acidic properties of mixtures of HCl with certain metallic chlorides. This work has demonstrated the existence, in certain cases, of acid complexes of the type (HCl) m MCl n . (author) [fr

  6. RT3D tutorials for GMS users

    Energy Technology Data Exchange (ETDEWEB)

    Clement, T.P. [Pacific Northwest National Lab., Richland, WA (United States); Jones, N.L. [Brigham Young Univ., Provo, UT (United States)

    1998-02-01

    RT3D (Reactive Transport in 3-Dimensions) is a computer code that solves coupled partial differential equations that describe reactive-flow and transport of multiple mobile and/or immobile species in a three dimensional saturated porous media. RT3D was developed from the single-species transport code, MT3D (DoD-1.5, 1997 version). As with MT3D, RT3D also uses the USGS groundwater flow model MODFLOW for computing spatial and temporal variations in groundwater head distribution. This report presents a set of tutorial problems that are designed to illustrate how RT3D simulations can be performed within the Department of Defense Groundwater Modeling System (GMS). GMS serves as a pre- and post-processing interface for RT3D. GMS can be used to define all the input files needed by RT3D code, and later the code can be launched from within GMS and run as a separate application. Once the RT3D simulation is completed, the solution can be imported to GMS for graphical post-processing. RT3D v1.0 supports several reaction packages that can be used for simulating different types of reactive contaminants. Each of the tutorials, described below, provides training on a different RT3D reaction package. Each reaction package has different input requirements, and the tutorials are designed to describe these differences. Furthermore, the tutorials illustrate the various options available in GMS for graphical post-processing of RT3D results. Users are strongly encouraged to complete the tutorials before attempting to use RT3D and GMS on a routine basis.

  7. Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

    Science.gov (United States)

    Gao, Weijie; Jin, Yinghui; Wang, Yan; Sun, Mei; Chen, Baoyuan; Zhou, Ning; Deng, Yuan

    2012-06-01

    It is costly and time-consuming to conduct the standard manual titration to identify an effective pressure before continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) patients. Automatic titration is cheaper and more easily available than manual titration. The purpose of this systematic review was to evaluate the effect of automatic titration in identifying a pressure and on the improvement of apnea/hyponea index (AHI) and somnolence, the change of sleep quality, and the acceptance and compliance of CPAP treatment, compared with the manual titration. A systematic search was made of the PubMed, EMBASE, Cochrane Library, SCI, China Academic Journals Full-text Databases, Chinese Biomedical Literature Database, Chinese Scientific Journals Databases and Chinese Medical Association Journals. Randomized controlled trials comparing automatic titration and manual titration were reviewed. Studies were pooled to yield odds ratios (OR) or mean differences (MD) with 95% confidence intervals (CI). Ten trials involving 849 patients met the inclusion criteria. It is hard to identify a trend in the pressures determined by either automatic or manual titration. Automatic titration can improve the AHI (MD = 0.03/h, 95% CI = -4.48 to 4.53) and Epworth sleepiness scale (SMD = -0.02, 95% CI = -0.34 to 0.31,) as effectively as the manual titration. There is no difference between sleep architecture under automatic titration or manual titration. The acceptance of CPAP treatment (OR = 0.96, 95% CI = 0.60 to 1.55) and the compliance with treatment (MD = -0.04, 95% CI = -0.17 to 0.10) after automatic titration is not different from manual titration. Automatic titration is as effective as standard manual titration in improving AHI, somnolence while maintaining sleep quality similar to the standard method. In addition, automatic titration has the same effect on the acceptance and compliance of CPAP treatment as manual titration. With the potential advantage

  8. Using CoRT Thinking in Schools.

    Science.gov (United States)

    Melchior, Timothy M.; And Others

    1988-01-01

    Describes the use of Edward de Bono's CoRT (Cognitive Research Trust) program in English classes during the past five years at Memorial Junior High School in Valley Stream, New York. CoRT tools were used to analyze literary characters and plot development and to generate and organize ideas for writing assignments. (TE)

  9. Separation and characterization of resins and asphaltenes coming from Castilla crude Evaluation of their molecular interaction

    International Nuclear Information System (INIS)

    Navarro, Lina; Alvarez, Mario; Grosso, Jorge Luis; Navarro, Uriel

    2004-01-01

    The study of resins and asphaltenes, the heaviest fractions of oil, has become an area of interest due to the abundance of heavy crude oils in Colombia and Latin America. We studied the chemical composition of the heavy fractions of Castilla crude oil, evaluated some of its molecular parameters and found evidence of the interaction between the resins extracted from the crude with the asphaltenes of the original crude. With this objective, we carried out at the pilot plant level precipitation of the resin-asphaltene (R-A) aggregate by adding and mixing under controlled conditions, a paraffin solvent, from the Apiay refinery, called Apiasol. By extracting Soxhlet with the same solvent, resin 1 of aggregate R-A was separated. Resin ll defined as the soluble fraction that is part of the maltenes, was separated from the deasphalted crude by open column chromatography, using alumina as support, according to the SAR method (Saturated, Aromatics, Resins). The fractions of resins and the asphaltenes obtained, were characterized by: Nuclear Magnetic Resonance (NMR), FT-lR, DRX, elementary analysis (C, H, N, S), metal content (Ni and V), distribution of molecular weight by GPC, and average molecular weight by VPO. The results obtained show evidence that resin l which is part of the aggregate has less average molecular weight than resin ll which is present in the fraction of maltenes. In addition, some changes were found in the elementary analysis of among the resins. On the one hand, and taking into account the existing theories of molecular interactions among these fractions, it was found that the resins l separated from the R-A aggregate, when added to the crude, they stabilize their asphaltenes. This evaluation was carried out by analyzing the flocculation point of the crude and its mixtures with 1,9% and 3,8% of resin l, when they are titrated with a precipitating agent in an NIR cell that works with high pressure and temperature

  10. An Engineering Evaluation of Spherical Resorcinol Formaldehyde Resin

    Energy Technology Data Exchange (ETDEWEB)

    Birdwell Jr, Joseph F [ORNL; Lee, Denise L [ORNL; Taylor, Paul Allen [ORNL; Collins, Robert T [ORNL; Hunt, Rodney Dale [ORNL

    2010-09-01

    , quantification of cesium adsorption performance as a function of operating temperature and pH, and evaluation of sodium uptake (titration) as function of pH and counteranion concentration. The results of these efforts are presented in this report. Hydraulic performance of the resin and the use of eluant alternatives to nitric acid have also been evaluated and have been reported elsewhere (Taylor 2009, Taylor and Johnson 2009).

  11. Reduction of polyester resin shrinkage by means of epoxy resin

    International Nuclear Information System (INIS)

    Pietrzak, M.; Brzostowski, A.

    1981-01-01

    An attempt was made to decrease the shrinkage of unsaturated polyester resin, taking place during radiation-induced curing, by the addition of epoxy resin. In order to combine chemically both resins, the epoxy component was modified with cinnamic and acrylic acids. A composition of 90 parts of polyester resin, 10 parts of epoxy resin modified with cinnamic acid, and 150 parts of a silica filler showed a volume shrinkage of 1.2%. (author)

  12. Synthesis, Characterization and Glass - Reinforced Composites of Thiourea - Formaldehyde - Phenol Resin

    Directory of Open Access Journals (Sweden)

    Kanuprasad Dahyalal Patel

    2004-01-01

    Full Text Available N,N'-Dimethylol thiourea-formaldehyde (DMTUF resin having the methylol group (CH2OH has been prepared and characterized. The condensation of DMTUF resin with Phenol (P was carried out in the presence of alcoholic alkali catalyst at varying ratios of DMTUF: P, namely 1:1, 1:1.5 and 1:2. The resultant DMTUFP resin was characterized by elemental analysis, IR spectral studies, number average molecular weight ( M¯n estimated by non-aqueous conductometric titration, and thermo gravimetry. The curing study of DMTUFP resin with hexamethylene tetramine (HMTA was monitored by differential scanning calorimetry (DSC and kinetic parameters were evaluated. Glass-reinforced composites based on the DMTUFP-HMTA system have also been prepared and characterized.

  13. Synthesis, Characterization and Glass - Reinforced Composites of N,N'-Dimethylolthiourea – m-Aminophenol Resin

    Directory of Open Access Journals (Sweden)

    K. D. Patel

    2005-01-01

    Full Text Available N,N’-Dimethylolthiourea (DMTU resin having the methylol group ( –CH2 OH has been prepared and characterized. The condensation of DMTU resin with m-aminophenol was carried out in the presence of alcoholic alkali catalyst at varying ratios of DMTU: mAP, namely 1:1, 1:1.5 and 1:2. The resultant DMTUmAP resin was characterized by elemental analysis, IR spectral studies, number average molecular weight (M¯n estimated by non-aqueous conductometric titration, and thermogravimetry. The curing study of DMTUmAP resin with hexamethylenetetramine (HMTA was monitored by differential scanning calorimetry (DSC and kinetic parameters were evaluated. Glass-reinforced composites based on the DMTUmAP-HMTA system have also been prepared and characterized.

  14. Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    OpenAIRE

    Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan

    2015-01-01

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000?). Mesial and distal 1/3 parts of the res...

  15. rt: Fratres / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1995-01-01

    Uuest heliplaadist "Pärt: Fratres (seven versions). Festina Lente. Cantus in Memory of Benjamin Britten. Summa. Peter Manning (vn.), France Springuel (vc.), Mireille Gleizes (pf.), I Fiamminghi. Telare CD CD80387 (79 minutes)

  16. Arvo Pärt. Litany / Peter Korfmacher

    Index Scriptorium Estoniae

    Korfmacher, Peter

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo. Litany; Psalom; Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste"; Lithuanian Chamber Orchestra, Saulius Sondeckis. ECM 1592/449 810-2

  17. rt: Berliner Messe / Rob Cowan

    Index Scriptorium Estoniae

    Cowan, Rob

    1998-01-01

    Uuest heliplaadist "Pärt: Berliner Messe. The Beatitudes. Annum per Annum. Magnificat. Seven Magnificat Antiphons. De profundis. Polyphony / Steven Layton with Andrew Lucas" Hyperion CDA66960 (74 minutes:DDD)

  18. Improving medication titration in heart failure by embedding a structured medication titration plan.

    Science.gov (United States)

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (pplan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Up-titration of allopurinol in patients with gout.

    Science.gov (United States)

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  1. Automated titration method for use on blended asphalts

    Science.gov (United States)

    Pauli, Adam T [Cheyenne, WY; Robertson, Raymond E [Laramie, WY; Branthaver, Jan F [Chatham, IL; Schabron, John F [Laramie, WY

    2012-08-07

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  2. A computer controlled potentiometric titrator for quantitative determination of uranium

    International Nuclear Information System (INIS)

    Verdingh, V.; Michiels, A.

    1988-01-01

    The modified Davies and Gray methods is frequently used for the potentiometric titration of uranium. It is based upon the reduction of U(VI) to U(IV) with a reductant (e.g. Fe ++ ) followed by a selective oxidation of the excess of reductant and subsequent titration of U(IV) with potassium dichromate (K 2 Cr 2 O 7 ). Interference from other elements is low, but the method is rather cumbersome due to the number of reactants to be added before the titration is started. The timing of these additions also plays a role. In order to render the titration less dependent on human factors and with the aim of reaching high reproducibility, a computer controlled system has been designed and set-up. Reagents are added by five computer controlled burettes. A program allows the choice of volumes and waiting times, and commands the start of the final titration which is followed by the microprocessor of the automatic potentiometric titrator. In this way a routine uranium titration can be completed in about twelve minutes. Reproducibilities of the order of ±15% are achievable in routine operation. For high precision work, the titrator is used as an end-point detector. Titrant is added manually by mass, so as to react with > 99% of the uranium. The residual uranium is then titrated automatically by colume with diluted titrant. The precision can be improved by a factor of approximately ten. (orig.)

  3. The acid-base titration of montmorillonite

    Science.gov (United States)

    Bourg, I. C.; Sposito, G.; Bourg, A. C.

    2003-12-01

    Proton binding to clay minerals plays an important role in the chemical reactivity of soils (e.g., acidification, retention of nutrients or pollutants). If should also affect the performance of clay barriers for waste disposal. The surface acidity of clay minerals is commonly modelled empirically by assuming generic amphoteric surface sites (>SOH) on a flat surface, with fitted site densities and acidity constant. Current advances in experimental methods (notably spectroscopy) are rapidly improving our understanding of the structure and reactivity of the surface of clay minerals (arrangement of the particles, nature of the reactive surface sites, adsorption mechanisms). These developments are motivated by the difficulty of modelling the surface chemistry of mineral surfaces at the macro-scale (e.g., adsorption or titration) without a detailed (molecular-scale) picture of the mechanisms, and should be progressively incorporated into surface complexation models. In this view, we have combined recent estimates of montmorillonite surface properties (surface site density and structure, edge surface area, surface electrostatic potential) with surface site acidities obtained from the titration of alpha-Al2O3 and SiO2, and a novel method of accounting for the unknown initial net proton surface charge of the solid. The model predictions were compared to experimental titrations of SWy-1 montmorillonite and purified MX-80 bentonite in 0.1-0.5 mol/L NaClO4 and 0.005-0.5 mol/L NaNO3 background electrolytes, respectively. Most of the experimental data were appropriately described by the model after we adjusted a single parameter (silanol sites on the surface of montmorillonite were made to be slightly more acidic than those of silica). At low ionic strength and acidic pH the model underestimated the buffering capacity of the montmorillonite, perhaps due to clay swelling or to the interlayer adsorption of dissolved aluminum. The agreement between our model and the experimental

  4. A Closer Look at Acid-Base Olfactory Titrations

    Science.gov (United States)

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  5. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    Science.gov (United States)

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  6. Titrated oral misoprostol solution- a new method of labour induction ...

    African Journals Online (AJOL)

    Titrated oral misoprostol solution- a new method of labour induction. ... To develop a new method of misoprostol use for labour induction using very small, frequent, titrated oral dosages, and to pilot effectiveness. Study design. Open clinical pilot ... A multicentre randomised trial of this method is underway. We emphasise the ...

  7. Automated proton titrations of pancreatic phospholipase A2

    NARCIS (Netherlands)

    Donné-Op den Kelder, G.M.; Haas, G.H. de; Egmond, M.R.

    1982-01-01

    A computer-controlled titration system has been developed, tested, and used for analysis of the proton-titration behavior of pancreatic phospholipase A2 from ox, horse, and pig. The results revealed an error in the reported amino acid composition of the equine enzyme. A simple interface for the

  8. a randomised trial comparing Foley catheter plus titrated oral ...

    African Journals Online (AJOL)

    Labour induction at term - a randomised trial comparing. Foley catheter plus titrated oral misoprostol solution, titrated oral misoprostol solution alone, and dinoprostone. Baron B Matonhodze, G Justus Hofmeyr, Jonathan Levin. Objectives. To compare three methods of labour induction. Design. Randomised controlled trial.

  9. New applications of corrosion measurements by titration (CMT)

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1998-01-01

    . It is shown that when aluminium dissolves in alkali, CMT measurements can also be applied, but in this case requiring titration with alkali. Titration with alkali is also required in a special situation, where corrosion of nickel in an acid solution and subsequent formation of a nickel complex results...

  10. The coulometric titration of acids and bases in dimethylsulfoxide media

    NARCIS (Netherlands)

    Bos, M.; IJpma, S.T.; Dahmen, E.A.M.F.

    1976-01-01

    The coulometric titration of 20–200 μeq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current

  11. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2008-12-09

    A resin recycling method that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The method includes receiving the resin in container form. The containers are then ground into resin particles. The particles are exposed to a solvent, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. After separating the particles and the resin, a solvent removing agent is used to remove any residual solvent remaining on the resin particles after separation.

  12. Artist - analytical RT inspection simulation tool

    International Nuclear Information System (INIS)

    Bellon, C.; Jaenisch, G.R.

    2007-01-01

    The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the prediction of its reliability, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the integrated project FilmFree the radiographic testing (RT) simulation software developed by BAM is being further developed to meet practical requirements for inspection planning in digital industrial radiology. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, railways and others. (authors)

  13. Contact allergy to epoxy resin

    DEFF Research Database (Denmark)

    Bangsgaard, Nannie; Thyssen, Jacob Pontoppidan; Menné, Torkil

    2012-01-01

    to epoxy resin remained stable over the study period. Of the patients with an epoxy resin-positive patch test, 71% returned a questionnaire; 95 patients had worked with epoxy resin in the occupational setting, and, of these, one-third did not use protective gloves and only 50.5% (48) had participated...

  14. A simplified method for active-site titration of lipases immobilised on hydrophobic supports.

    Science.gov (United States)

    Nalder, Tim D; Kurtovic, Ivan; Barrow, Colin J; Marshall, Susan N

    2018-06-01

    The aim of this work was to develop a simple and accurate protocol to measure the functional active site concentration of lipases immobilised on highly hydrophobic supports. We used the potent lipase inhibitor methyl 4-methylumbelliferyl hexylphosphonate to titrate the active sites of Candida rugosa lipase (CrL) bound to three highly hydrophobic supports: octadecyl methacrylate (C18), divinylbenzene crosslinked methacrylate (DVB) and styrene. The method uses correction curves to take into account the binding of the fluorophore (4-methylumbelliferone, 4-MU) by the support materials. We showed that the uptake of the detection agent by the three supports is not linear relative to the weight of the resin, and that the uptake occurs in an equilibrium that is independent of the total fluorophore concentration. Furthermore, the percentage of bound fluorophore varied among the supports, with 50 mg of C18 and styrene resins binding approximately 64 and 94%, respectively. When the uptake of 4-MU was calculated and corrected for, the total 4-MU released via inhibition (i.e. the concentration of functional lipase active sites) could be determined via a linear relationship between immobilised lipase weight and total inhibition. It was found that the functional active site concentration of immobilised CrL varied greatly among different hydrophobic supports, with 56% for C18, compared with 14% for DVB. The described method is a simple and robust approach to measuring functional active site concentration in immobilised lipase samples. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Enhancement of adhesion between resin coating materials and resin cements.

    Science.gov (United States)

    Udo, Tomoaki; Nikaido, Toru; Ikeda, Masaomi; Weerasinghe, Dinesh S; Harada, Naoko; Foxton, Richard M; Tagami, Junji

    2007-07-01

    Resin coating technique is a unique method that improves the dentin bond strength of resin cements in indirect restorations. However, the weak link of a specimen bonded using the resin coating technique was reported to be the bonded interface between the resin coating material and resin cement. The purpose of this study, therefore, was to enhance the bonding performance between a resin coating material and a resin cement. Two light-cured flowable composites, Protect Liner F and Clearfil Flow FX, were used as coating materials, and two dual-cure composite materials, Panavia F 2.0 and Clearfil DC Core Automix, were used as resin cements. The ultimate tensile strength of each material and the microtensile bond strengths of the bonded specimens of resin coating material and resin cement were measured using a crosshead speed of 1.0 mm/min. Three-way ANOVA (p=0.05) revealed that the highest microtensile bond strength was obtained using a combination of Clearfil Flow FX and Clearfil DC Core Automix, and when the surface of the coating material was treated with ED Primer II. It was strongly suggested that materials with a higher ultimate tensile strength, when used in both resin coating and cementation, could enhance the bond strength between the two.

  16. Resin impregnation process for producing a resin-fiber composite

    Science.gov (United States)

    Palmer, Raymond J. (Inventor); Moore, William E. (Inventor)

    1994-01-01

    Process for vacuum impregnation of a dry fiber reinforcement with a curable resin to produce a resin-fiber composite, by drawing a vacuum to permit flow of curable liquid resin into and through a fiber reinforcement to impregnate same and curing the resin-impregnated fiber reinforcement at a sufficient temperature and pressure to effect final curing. Both vacuum and positive pressure, e.g. autoclave pressure, are applied to the dry fiber reinforcement prior to application of heat and prior to any resin flow to compact the dry fiber reinforcement, and produce a resin-fiber composite of reduced weight, thickness and resin content, and improved mechanical properties. Preferably both a vacuum and positive pressure, e.g. autoclave pressure, are also applied during final curing.

  17. rt, Arvo: "Litany" / Barry Witherden

    Index Scriptorium Estoniae

    Witherden, Barry

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: "Litany". Litany. Psalom. Trisagion. The Hilliard Ensemble, Tallinn Chamber Orchestra, Estonian Philharmonic Chamber Orchestra, Estonian Philharmonic Chamber Choir, Tõnu Kaljuste. Orchestre de chambre de Lituanie, Saulius Sondeckis". ECM New Series ECM 1592, distribution Polygram 449 810-2 (CD:158F)

  18. rt, Arvo: "Litany" / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: "Litany". Litany. Psalom. Trisagion. The Hilliard Ensemble, Orchestre de chambre de Tallinn, Choeur de chambre Philharmonique d'Estonie, Tõnu Kaljuste. Orchestre de chambre de Lituanie, Saulius Sondeckis. ECM New Series ECM 1592, distribution Polygram 449 810-2 (CD:158F)

  19. Forført af hjernen?

    DEFF Research Database (Denmark)

    Lieberoth, Andreas

    2013-01-01

    Blandingen af offentlig interesse, gode mediehistorier og smarte sælgere har ført til sejlivede neuromyter, der ikke bare distraherer almindelige mennesker, men også fører til udbredte misforståelser blandt professionelle som lærere og plejepersonale. I bedste fald leder neuromyter til spild af t...

  20. rt, Arvo. Fratres / Rainer Wagner

    Index Scriptorium Estoniae

    Wagner, Rainer

    1995-01-01

    Uuest heliplaadist "Pärt, Arvo. Fratres, Cantus (in Memory of Benjamin Britten), summa, Festina Lente; Peter Manning, France Springuel, Mireille Gleizes, Huub Righarts, I Fiamminghi, Rudolf Werthen" (AD: 1994) Telarc/in-akustik CD 80 387 (WD: 79'00")

  1. Titration and hysteresis in epigenetic chromatin silencing

    Science.gov (United States)

    Dayarian, Adel; Sengupta, Anirvan M.

    2013-06-01

    Epigenetic mechanisms of silencing via heritable chromatin modifications play a major role in gene regulation and cell fate specification. We consider a model of epigenetic chromatin silencing in budding yeast and study the bifurcation diagram and characterize the bistable and the monostable regimes. The main focus of this paper is to examine how the perturbations altering the activity of histone modifying enzymes affect the epigenetic states. We analyze the implications of having the total number of silencing proteins, given by the sum of proteins bound to the nucleosomes and the ones available in the ambient, to be constant. This constraint couples different regions of chromatin through the shared reservoir of ambient silencing proteins. We show that the response of the system to perturbations depends dramatically on the titration effect caused by the above constraint. In particular, for a certain range of overall abundance of silencing proteins, the hysteresis loop changes qualitatively with certain jump replaced by continuous merger of different states. In addition, we find a nonmonotonic dependence of gene expression on the rate of histone deacetylation activity of Sir2. We discuss how these qualitative predictions of our model could be compared with experimental studies of the yeast system under anti-silencing drugs.

  2. Titration and hysteresis in epigenetic chromatin silencing

    International Nuclear Information System (INIS)

    Dayarian, Adel; Sengupta, Anirvan M

    2013-01-01

    Epigenetic mechanisms of silencing via heritable chromatin modifications play a major role in gene regulation and cell fate specification. We consider a model of epigenetic chromatin silencing in budding yeast and study the bifurcation diagram and characterize the bistable and the monostable regimes. The main focus of this paper is to examine how the perturbations altering the activity of histone modifying enzymes affect the epigenetic states. We analyze the implications of having the total number of silencing proteins, given by the sum of proteins bound to the nucleosomes and the ones available in the ambient, to be constant. This constraint couples different regions of chromatin through the shared reservoir of ambient silencing proteins. We show that the response of the system to perturbations depends dramatically on the titration effect caused by the above constraint. In particular, for a certain range of overall abundance of silencing proteins, the hysteresis loop changes qualitatively with certain jump replaced by continuous merger of different states. In addition, we find a nonmonotonic dependence of gene expression on the rate of histone deacetylation activity of Sir2. We discuss how these qualitative predictions of our model could be compared with experimental studies of the yeast system under anti-silencing drugs. (paper)

  3. A dipstick sensor for coulometric acid-base titrations

    OpenAIRE

    Olthuis, Wouter; van der Schoot, B.H.; Chavez, F.; Bergveld, Piet

    1989-01-01

    By performing an acid-base titration by coulometric generation of OH− or H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in the titration curve. Typical values for the titration time are 0.1 to 10 s for acid or base concentrations ranging from 0.5 × 10−3 to 10 × 10−3 mol/l. By placing the counter electrode for the supp...

  4. The fluorimetric titration of zirconium in the ppm-range

    International Nuclear Information System (INIS)

    Linden, W.E. von der; Boef, G. den; Ozinga, W.

    1976-01-01

    A fluorimetric titration of zirconium(IV) with EDTA is proposed. The fluorescence intensity of the zirconium-morin complex is used to indicate the end-point. More than twenty other cations were investigated and it was found that they did not interfere, neither did common anions. Mercury(II) can only be tolerated in amount not exceeding that of zirconium. Bismuth(III) interferes and hafnium(IV0 is titrated together with zirconium. The relative standard deviation of the titration of 10ml of a solution containing 1 ppm of zirconium does not exceed 1.5%

  5. Determination of boron as boric acid by automatic potentiometric titration

    International Nuclear Information System (INIS)

    Midgley, D.

    1988-06-01

    Boron in PWR primary coolant and related waters may be determined as boric acid by titration with sodium hydroxide, using a glass electrode as a pH indicator. With a modern automatic titrator, the analysis is quick, convenient, accurate and precise. In the titration of 8 mg B (e.g. 4 ml of 2000 mg 1 -1 solution), no significant bias was observed and relative standard deviations were about 0.25%. With 0.8 g B, a bias of about 2% appears, although this could be reduced by restandardizing the titrant, but the relative standard deviation was still -1 B, depending on the stage of the fuel cycle. (author)

  6. Synthesis, Chacterization, and Thermal Study of Terpolymeric Resin Derived from m-cresol, Hexamine and Formaldehyde

    Directory of Open Access Journals (Sweden)

    K. M. Khedkar

    2012-01-01

    Full Text Available Terpolymeric resin was prepared from m-cresol (0.1M, hexamine (0.05M and formaldehyde (0.2M by acid catalyzed polycondensation method using 1M HCl in temperature range of 122-130°C.The resin was abbreviated as m-CHF-I. The molecular weight of terpolymer was determined by non-aqueous conductometric titration technique. The structure of resin was determined by its elemental analysis, UV-VIS, IR, and NMR data. The thermokinetic parameters were determined using Freeman-Carroll (FC and Sharp Wentworth (SW method in temperature range (410-485°C.The values of activation energies (Ea, entropy (∆S, and free energies (∆G were in good agreement . The order of degradation reaction determined by FC method was confirmed by SW method.

  7. Green chemistry volumetric titration kit for pharmaceutical formulations: Econoburette

    Directory of Open Access Journals (Sweden)

    Man Singh

    2009-08-01

    Full Text Available Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR, Ministry of Small Scale Industries, Government of India, developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and conical flask by inbuilt bulb. A step of pipetting of stock solution by mouth is deleted. It is used to allow solution exposure to user’s body. This risk is removed and even volatile and toxic solutions are titrated with full proof safety. Econoburette minimizes use of materials and time by 90 % and prevent discharge of polluting effluent to environment. Few acid and base samples are titrated and an analysis of experimental expenditure is described in the papers.

  8. Spectrophotometric titration of sulfates in the presence of zirconium

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  9. Coulometric titration of niobium in 1F sulfuric acid

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1975-01-01

    A coulometric titration at constant current has been devised for Nb in 1F sulfuric acid. The titration was based on the oxidation of Nb(III) to Nb(V) by Fe(III) electrogenerated at a graphite anode. Both potentiometric and amperometric end points were used. The Nb(V) was prior reduced at a mercury cathode by exhaustive electrolysis at a current density of 15 ma/mc 2 for at least 10 hr. Ta,V,Ti and a working platinum anode interfered, but the separation of the potentials of Nb(V)/Nb(III) and Ti(IV)/Ti(III) permitted the titration of first Nb and then Ti. The average error for the titration of 0.30 to 13.00 mg of niobium in 100 ml of 1F sulfuric acid was + 0.57%. (author)

  10. Coulometric titration of niobium in EDTA complexing solution

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1976-01-01

    Constant current coulometry of Nb in EDTA was studied employing both potentiometric and amperometric end-point techniques. The titrations were based on the oxidation of Nb(IV)-EDTA with electrogenerated Fe(III) at a graphite anode. The rate of disproportionation of Nb(IV)-EDTA was found to be slow enough not to effect the accuracy sought for the titration. The coulometric titration of Nb in EDTA was found to be more accurate than in 1F sulfuric acid. The mean error in the titrations of 4.76 to 19.65 of Nb in a volume of about 100 ml of 0.02 to 0.04F EDTA was 0.13%. It was found that Ta may be tolerated to a ratio of 1:4, Ta:Nb, in a solution containing 13 mg of Nb. (author)

  11. Potentiometric titration of free acid in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors` researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors` researches are appended. (author). 26 refs., 54 figs.

  12. Microscope Titration and Extraction of DNA from Liver.

    Science.gov (United States)

    Mayo, Lois T.; And Others

    1993-01-01

    Describes a simple and inexpensive, one-period activity to extract DNA to make the study of DNA less abstract. A microscope titration is used to determine when cells are ready for DNA extraction. (PR)

  13. A microcomputer-controlled system for titration analysis

    NARCIS (Netherlands)

    Boelema, Gerrit Jan

    1982-01-01

    This thesis deals with the results of the implementation of microprocessor technology in automatic titration equipment to obtain a versatile system for pharmaceutical, chemical analytical and optimization research purposes. ... Zie: Summary

  14. Analysis of the Purity of Cetrimide by Titrations

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Nielsen, Hans/Boye

    2006-01-01

    The purity of cetrimide, trimethyl tetradecyl ammonium bromide (TTAB), that is an important preservative of many cosmetic and pharmaceutical products, was determined by three independent methods of titration. Traditionally, cetrimide was analysed by an assay method of the European Pharmacopoeia (Ph....... Eur.), which showed consistently a low purity of cetrimide with large standard deviations associated, however. A systematic 3% bias of the Ph. Eur. assay method was identified by comparing the result with results of two alternative methods of titration that exhibited high precision and high accuracy....... Titration by perchloric acid showed a 99.69 ± 0.05 % purity of cetrimide and titration by silver nitrate showed a 99.85% ± 0.05 % purity while the traditional assay method predicted a purity of only 97.1 ± 0.4. It was found that the discrepancy could be identified as differences in selectivity during...

  15. Plutonium volumetric titration after reduction on a Jones' column

    International Nuclear Information System (INIS)

    Description of a plutonium analysis method, in hydrochloric or sulfuric solution, for plutonium content over 2 mg, by reduction from plutonium IV to plutonium III in a Jones' column. Volumetic titration by ceric sulfate with ferrous orthophenanthroline [fr

  16. Dissociation of weak acids during Gran plot free acidity titrations

    OpenAIRE

    Lindberg, Steven E:; Cole, Jan M.

    2011-01-01

    A comparison of weak and free acid concentrations measured by base titration and hydrogen ionactivities determined by direct pH measurement is described for several of our data sets for raincollected above and below a forest canopy in the eastern United States. These data illustrate theinfluence of weak acid dissociation during titration and the possible effect of activity coefficientson calculated free acid concentrations.DOI: 10.1111/j.1600-0889.1984.tb00240.x

  17. Amperometric titration of indium with edta solution in propanol

    International Nuclear Information System (INIS)

    Gevorgyan, A.M.; Talipov, Sh.T.; Khadeev, V.A.; Kostylev, V.S.; Khadeeva, L.A.

    1980-01-01

    Optimum conditions have been chosen for titration of indium with EDTA solution in anhydrous propanol and its mixtures with some aprotic solvents using amperometric and point detection. A procedure is suggested of determining indium microcontents in the presence of large amounts of other elements. The procedure is based on its extraction preseparation followed by direct titration in the extract with a standard EDTA solution [ru

  18. Carbon dioxide titration method for soil respiration measurements

    OpenAIRE

    Martín Rubio, Luis

    2017-01-01

    This thesis was commissioned by Tampere University of Applied Sciences, which was interested in studying and developing a titration measurement method for soil respiration and biodegradability. Some experiments were carried out measuring soil respiration for testing the method and others adding some biodegradable material like polylactic acid compressed material and 100% biodegradable plastic bags to test its biodegradability and the possibility to measure it via titration. The thesi...

  19. Potentiometric and coulometric titration of 2-thiobarbituric acid.

    Science.gov (United States)

    Ciesielski, W; Kowalska, J; Zakrzewski, R

    1995-05-01

    A new method for the determination of 2-thiobarbituric acid, using its reaction with iodine in an alkaline medium is presented. In the volumetric titration with potentiometric end-point detection, the determinability range is 10-400 micromol (1.4-58 mg). In coulometric titration using the biamperometric end-point detection, 0.1-20 micromol (1.4 x 10(-2)-2.9 mg) of 2-thiobarbituric acid was successfully determined.

  20. Flame Retardant Epoxy Resins

    Science.gov (United States)

    Thompson, C. M.; Smith, J. G., Jr.; Connell, J. W.; Hergenrother, P. M.; Lyon, R. E.

    2004-01-01

    As part of a program to develop fire resistant exterior composite structures for future subsonic commercial aircraft, flame retardant epoxy resins are under investigation. Epoxies and their curing agents (aromatic diamines) containing phosphorus were synthesized and used to prepare epoxy formulations. Phosphorus was incorporated within the backbone of the epoxy resin and not used as an additive. The resulting cured epoxies were characterized by thermogravimetric analysis, propane torch test, elemental analysis and microscale combustion calorimetry. Several formulations showed excellent flame retardation with phosphorous contents as low as 1.5% by weight. The fracture toughness of plaques of several cured formulations was determined on single-edge notched bend specimens. The chemistry and properties of these new epoxy formulations are discussed.

  1. Gran method for end point anticipation in monosegmented flow titration

    Directory of Open Access Journals (Sweden)

    Aquino Emerson V

    2004-01-01

    Full Text Available An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 mL of sample and about the same volume of titrant (AgNO3 solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision (relative standard deviation of ten replicates are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.

  2. Bismaleimide Copolymer Matrix Resins

    Science.gov (United States)

    Parker, John A.; Heimbuch, Alvin H.; Hsu, Ming-Ta S.; Chen, Timothy S.

    1987-01-01

    Graphite composites, prepared from 1:1 copolymer of two new bismaleimides based on N,N'-m-phenylene-bis(m-amino-benzamide) structure have mechanical properties superior to those prepared from other bismaleimide-type resins. New heat-resistant composites replace metal in some structural applications. Monomers used to form copolymers with superior mechanical properties prepared by reaction of MMAB with maleic or citraconic anhydride.

  3. System for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  4. Paramagnetic epoxy resin

    Directory of Open Access Journals (Sweden)

    E. C. Vazquez Barreiro

    2017-01-01

    Full Text Available This work illustrates that macrocycles can be used as crosslinking agents for curing epoxy resins, provided that they have appropriate organic functionalities. As macrocycles can complex metal ions in their structure, this curing reaction allows for the introduction of that metal ion into the resin network. As a result, some characteristic physical properties of the metallomacrocycle could be transferred to the new material. The bisphenol A diglycidyl ether (BADGE, n = 0 and hemin (a protoporphyrin IX containing the Fe(III ion, and an additional chloride ligand have been chosen. The new material has been characterized by differential scanning calorimetry (DSC, thermogravimetric analysis (TGA, Fourier Transform Infrared (FT-IR, Nuclear Magnetic Resonance (NMR, Transmission Electron Microscopy (TEM, and magnetic susceptibility measurements. Fe(III remains in the high-spin state during the curing process and, consequently, the final material exhibits the magnetic characteristics of hemin. The loss of the chlorine atom ligand during the cure of the resin allows that Fe(III can act as Lewis acid, catalyzing the crosslinking reactions. At high BADGE n = 0/hemin ratios, the formation of ether and ester bonds occurs simultaneously during the process.

  5. Microshear bond strength of preheated silorane- and methacrylate-based composite resins to dentin.

    Science.gov (United States)

    Demirbuga, Sezer; Ucar, Faruk Izzet; Cayabatmaz, Muhammed; Zorba, Yahya Orcun; Cantekin, Kenan; Topçuoğlu, Hüseyin Sinan; Kilinc, Halil Ibrahim

    2016-01-01

    The aim of this study was to investigate the effect of preheating on microshear bond strength (MSBS) of silorane and methacrylate-based composite resins to human dentin. The teeth were randomly divided into three main groups: (1) composite resins were heated upto 68 °C; (2) cooled to 4 °C; and (3) control [room temperature (RT)]. Each group was then randomly subdivided into four subgroups according to adhesive system used [Solobond M (Voco), All Bond SE (Bisco), Clearfil SE Bond (CSE) (Kuraray), Silorane adhesive system (SAS) (3M ESPE)]. Resin composite cylinders were formed (0.9 mm diameter × 0.7 mm length) and MSBS of each specimen was tested. The preheated groups exhibited the highest MSBS (p composite resins may be an alternative way to increase the MSBS of composites on dentin. © Wiley Periodicals, Inc.

  6. Detecting Levels of Polyquaternium-10 (PQ-10) via Potentiometric Titration with Dextran Sulphate and Monitoring the Equivalence Point with a Polymeric Membrane-Based Polyion Sensor.

    Science.gov (United States)

    Ferguson, Stephen A; Wang, Xuewei; Meyerhoff, Mark E

    2016-08-07

    Polymeric quaternary ammonium salts (polyquaterniums) have found increasing use in industrial and cosmetic applications in recent years. More specifically, polyquaternium-10 (PQ-10) is routinely used in cosmetic applications as a conditioner in personal care product formulations. Herein, we demonstrate the use of potentiometric polyion-sensitive polymeric membrane-based electrodes to quantify PQ-10 levels. Mixtures containing both PQ-10 and sodium lauryl sulfate (SLS) are used as model samples to illustrate this new method. SLS is often present in cosmetic samples that contain PQ-10 (e.g., shampoos, etc.) and this surfactant species interferes with the polyion sensor detection chemistry. However, it is shown here that SLS can be readily separated from the PQ-10/SLS mixture by use of an anion-exchange resin and that the PQ-10 can then be titrated with dextran sulphate (DS). This titration is monitored by potentiometric polyanion sensors to provide equivalence points that are directly proportional to PQ-10 concentrations.

  7. Biokompatibilitas Gelas Ionomer Modifikasi Resin

    OpenAIRE

    Rotua Lestari M

    2008-01-01

    Saat ini banyak berkembang material baru dalam dunia kedokteran gigi diantaranya adalah Gelas ionomer modifikasi resin yang dikembangkan untuk mengatasi kekurangan-kekurangan dari gelas ionomer konvensional. Adanya penambahan monomer resin daIam bentuk 2-hydroxyethylmetacylate (HEMA) telah meningkatkan kekuatan dari bahan ini. Gelas ionomer modifikasi resin mempunyai sifat-sifat fisis dan mekanis yang lebih baik dibandingkan dengan gelas ionomer konvensional. Gelas ionomer modifikasi ...

  8. Rapid clozapine titration in treatment-refractory bipolar disorder.

    Science.gov (United States)

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    Science.gov (United States)

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  10. An eco-friendly synthesis, characterization, morphology and ion exchange properties of terpolymer resin derived from p-hydroxybenzaldehyde

    Directory of Open Access Journals (Sweden)

    Deepti B. Patle

    2016-09-01

    Full Text Available A novel chelating terpolymer resin has been synthesized through the terpolymerization of p-hydroxybenzaldehyde and biuret with formaldehyde (p-HBBF in 1:1:2 mol ratio using hydrochloric acid as a reaction medium by condensation technique. The synthesized terpolymer resin was characterized by elemental analysis, FTIR, 1H NMR and 13C NMR spectroscopy. On basis of the spectral studies, the structure of the terpolymer resin was proposed. The physico-chemical parameters have been evaluated for the terpolymer resin. Non-aqueous conductometric titration was used to determine the average molecular weight and polydispersity of the p-HBBF terpolymer resin and the intrinsic viscosity was also determined. The semicrystalline nature of the synthesized terpolymer was established by scanning electron microscopy (SEM. Terpolymer (p-HBBF synthesized is proved to be selective chelating ion exchange terpolymer resin for certain metals. Chelating ion exchange properties of this polymer was studied for Fe3+, Cu2+, Cd2+, Zn2+, Ni2+ and Pb2+ ions. A batch equilibrium method was employed in the study of the selectivity of the distribution of a given metal ions between the polymer sample and a solution containing the metal ion. The morphology of the terpolymers was studied by scanning electron microscopy, showing amorphous nature of the resins therefore can be used as a selective ion-exchanger for certain metal ions.

  11. Ion Exchange Testing with SRF Resin FY2012

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Rinehart, Donald E.; Peterson, Reid A.

    2013-06-11

    Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0 , which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

  12. [Titration comparative study of TOPINA Tablets in patients with localization related epilepsy: double-blind comparative study by rapid and slow titration methods].

    Science.gov (United States)

    Kaneko, Sunao; Inoue, Yushi; Sasagawa, Mutsuo; Kato, Masaaki

    2012-04-01

    To compare the tolerability and efficacy of two titration methods (rapid and slow titration) for TOPINA Tablets with different dosages and periods of escalation, a double-blind comparative study was conducted in patients with localization-related epilepsy. A total of 183 patients were randomized to either rapid titration (initial dosage 100 mg/day increased by 100-200 mg at weekly intervals) or to slow titration (initial dosage 50 mg/day increased in 50 mg/day increments at weekly intervals). TOPINA Tablets were administered for 12 weeks to the maximum dosage of 400 mg/day. The incident of adverse events leading to treatment interruptions or withdrawals was 18.9% in rapid titration and 14.8% in slow titration, with no statistical significance (p = 0.554). The incident of adverse events and adverse reactions of slow titration was slightly lower than that of rapid titration. The common adverse events and adverse reactions reported in the two titration methods were comparable and were well tolerated. On the other hand, the efficacy of slow titration, percent reduction in seizure rate and responder rate, was comparable with that of rapid titration. In conclusion, there were no significant differences of therapeutic response to TOPINA Tablets between the two titration methods.

  13. Development of one-step SYBR Green real-time RT-PCR for quantifying bovine viral diarrhea virus type-1 and its comparison with conventional RT-PCR

    Directory of Open Access Journals (Sweden)

    Lou Sai

    2011-07-01

    Full Text Available Abstract Background Bovine viral diarrhea virus (BVDV is a worldwide pathogen in cattle and acts as a surrogate model for hepatitis C virus (HCV. One-step real-time fluorogenic quantitative reverse transcription polymerase chain reaction (RT-PCR assay based on SYBR Green I dye has not been established for BVDV detection. This study aims to develop a quantitative one-step RT-PCR assay to detect BVDV type-1 in cell culture. Results One-step quantitative SYBR Green I RT-PCR was developed by amplifying cDNA template from viral RNA and using in vitro transcribed BVDV RNA to establish a standard curve. The assay had a detection limit as low as 100 copies/ml of BVDV RNA, a reaction efficiency of 103.2%, a correlation coefficient (R2 of 0.995, and a maximum intra-assay CV of 2.63%. It was 10-fold more sensitive than conventional RT-PCR and can quantitatively detect BVDV RNA levels from 10-fold serial dilutions of titrated viruses containing a titer from 10-1 to 10-5 TCID50, without non-specific amplification. Melting curve analysis showed no primer-dimers and non-specific products. Conclusions The one-step SYBR Green I RT-PCR is specific, sensitive and reproducible for the quantification of BVDV in cell culture. This one-step SYBR Green I RT-PCR strategy may be further optimized as a reliable assay for diagnosing and monitoring BVDV infection in animals. It may also be applied to evaluate candidate agents against HCV using BVDV cell culture model.

  14. Properties of the Carboxylate ion exchange resins

    International Nuclear Information System (INIS)

    Allard, Bert; Dario, Maarten; Boren, Hans; Torstenfelt, Boerje; Puigdomenech, Ignasi; Johansson, Claes

    2002-09-01

    Weakly acidic, carboxylic resin has been selected, together with strong base anion resins, for water purification at the Forsmark 1 and 2 reactors. For the strong (but not the weak) ion exchange resin the Nuclear Power Inspectorate has given permission to dispose the spent resins in the SFR 1 (the Final Repository for Radioactive Operational Waste). This report gives a review of the carboxylic resins and comes to the conclusion that the resins are very stable and that there should not exist any risks for increased leaching of radionuclides from SFR 1 if these resins are disposed (compared to the strong resins)

  15. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  16. Cure shrinkage in casting resins

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J. Brock [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    A method is described whereby the shrinkage of a casting resin can be determined. Values for the shrinkage of several resin systems in frequent use by Sandia have been measured. A discussion of possible methods for determining the stresses generated by cure shrinkage and thermal contraction is also included.

  17. Determination of uranium by direct titration with dipicolinic acid

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1984-01-01

    Direct titration of uranium with dipicolinic acid, in the presence of Arsenazo I, is a simple, precise, and accurate method for uranium determination. The method is particularly attractive because it can be totally automated. Detecting the end point (color change from blue to pink) depends on the concentration range. For the Micro Method (1 to 20 ppM U in the solution titrated), the gradual color change is monitored spectrophotometrically. For the Macro Method (20 to 300 ppM), the end point is determined either visually or spectrophotometrically. The spectrophotometric end point is computed by fitting the titration curve. The relative standard deviation is +-1 to 3% for the Micro Method and +-0.3% for the Macro Method

  18. Coulometric titration of D(+)-glucose using its enzymatic oxidation.

    Science.gov (United States)

    Tanaka, T; Shutto, E; Mizoguchi, T; Fukushima, K

    2001-02-01

    A definitive method is described for the indirect assay of milligram quantities of D(+)-glucose by coulometric titration. D(+)-Glucose was aerobically oxidized by glucose oxidase in an acetate buffer solution (pH 5.1). Subsequently, the enzymatically formed hydrogen peroxide was titrated coulometrically with electrogenerated hypobromite in sodium bromide-sodium tetraborate medium of pH 8.6, with biamperometric end-point detection. Parameters affecting the enzymatically catalyzed oxidation and coulometric titration were evaluated. The optimized conditions for the oxidation of up to 20 mg of D(+)-glucose include the addition of 4500 U of glucose oxidase and stirring over a 10-min interval at 25 degrees C. Under proposed conditions, the assay values of several commercial D(+)-glucose reagents were somewhat lower than the guaranteed minimum values, with RSDs (n = 5) of 0.071 - 0.106%.

  19. Determination of tungsten by amperometric redox titration with dichromate

    Energy Technology Data Exchange (ETDEWEB)

    Wuensch, G.; Aupers, R.; Kranich, R.

    1985-11-01

    Tungsten is reduced by an excess of Cr(II) in about 10 M HCl. This is technically simpler than the use of reductor columns or liquid amalgams. Titration with Fe(III) or Cr(VI) first consumes the excess of Cr(II) and then oxidizes W(V) to W(VI). The potentiometric response of metal electrodes to W(V) is slow but biamperometric indication at Esub(pol) = 0.2 V applies well. A mixture of W, Fe and Mo can be analyzed in a consecutive titration. Only Ti interferes. As compared to the reductometric titration of W(VI) with Cr(II) the method uses a stable titrant and avoids deairating of the sample solution. Sample preparations for ferrotungsten, steel and wolframite ore are described. (orig.).

  20. Error assessment in recombinant baculovirus titration: evaluation of different methods.

    Science.gov (United States)

    Roldão, António; Oliveira, Rui; Carrondo, Manuel J T; Alves, Paula M

    2009-07-01

    The success of baculovirus/insect cells system in heterologous protein expression depends on the robustness and efficiency of the production workflow. It is essential that process parameters are controlled and include as little variability as possible. The multiplicity of infection (MOI) is the most critical factor since irreproducible MOIs caused by inaccurate estimation of viral titers hinder batch consistency and process optimization. This lack of accuracy is related to intrinsic characteristics of the method such as the inability to distinguish between infectious and non-infectious baculovirus. In this study, several methods for baculovirus titration were compared. The most critical issues identified were the incubation time and cell concentration at the time of infection. These variables influence strongly the accuracy of titers and must be defined for optimal performance of the titration method. Although the standard errors of the methods varied significantly (7-36%), titers were within the same order of magnitude; thus, viral titers can be considered independent of the method of titration. A cost analysis of the baculovirus titration methods used in this study showed that the alamarblue, real time Q-PCR and plaque assays were the most expensive techniques. The remaining methods cost on average 75% less than the former methods. Based on the cost, time and error analysis undertaken in this study, the end-point dilution assay, microculture tetrazolium assay and flow cytometric assay were found to be the techniques that combine all these three main factors better. Nevertheless, it is always recommended to confirm the accuracy of the titration either by comparison with a well characterized baculovirus reference stock or by titration using two different methods and verification of the variability of results.

  1. Power lies in interdisciplinary cooperation / Kärt Summatavet ; interv. Kärt Blumberg

    Index Scriptorium Estoniae

    Summatavet, Kärt, 1963-

    2008-01-01

    Ehtekunstnik Kärt Summatavet oma uudsest meetodist ehete valmistamisel - paberil oleva kujutise ülekandmisest arvuti abil metallile, mille ta töötas väljas oma doktoritöö raames Soomes Helsingi Kunsti- ja Disainiülikoolis ning mis pälvis Soulis toimunud ülemaailmsel naisleiutajate konkursil hõbemedali

  2. Potentiometric and coulometric titration of 6-propyl-2-thiouracil.

    Science.gov (United States)

    Ciesielski, W; Zakrzewski, R

    1997-05-01

    A method for the determination of 6-propyl-2-thiouracil involving its reaction with iodine in an alkaline medium is presented. In volumetric titration with potentiometric end-point detection, the range of determination is 125-500 mumol (21-85 mg). In coulometric titration using biamperometric end-point detection, 0.5-5.0 mumol (0.085-0.85 mg) of 6-propyl-2-thiouracil was successfully determined. The RSD in all applied techniques was < 1%. The methods developed were applied to the determination of 6-propyl-2-thiouracil in tablets.

  3. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  4. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  5. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  6. 21 CFR 872.3140 - Resin applicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin applicator. 872.3140 Section 872.3140 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3140 Resin applicator. (a) Identification. A resin applicator is a brushlike device intended for use in spreading dental resin on a tooth during application of...

  7. potentiometric titration curves of aluminium salt solutions and its

    African Journals Online (AJOL)

    a

    species, which set up a base to study on the hydrolysis-polymerization of Al3+. At the same time, significant effects of total aluminum concentration, temperature, halide ion, silicate radical, and organic acid radical on the titration curves and its critical points were observed. Given the three critical points which demarcating the ...

  8. Potentiometric titration curves of aluminium salt solutions and its ...

    African Journals Online (AJOL)

    At the same time, significant effects of total aluminum concentration, temperature, halide ion, silicate radical, and organic acid radical on the titration curves and its critical points were observed. Given the three critical points which demarcating the aluminum forms, we carry out a through investigation into the fundamental ...

  9. Acid/base titrations of simulated PWR crevice environments

    International Nuclear Information System (INIS)

    Pang, J.; Macdonald, D.D.; Millett, P.J.

    1993-01-01

    The construction and operation of a titration system that is capable of exploring the acid/base properties of aqueous systems at temperatures solution is measured using YSZ sensors of the type Hg/HgO/ZrO 2 (Y 2 O 3 )/Solution in conjunction with a suitable reference electrode. The use of the system for measuring the pH of the titrated solutions (NaOH/H 2 SO 4 ) is discussed, and we show that the YSZ pH sensor is capable of consistent and precise pH measurements at elevated temperature (275-325 degrees C) and pressures (100-150 bars). However, the accuracy of the measured pH depends critically on the performance of the reference electrode. In the present work, we ensure the viability of the reference electrode. In the present work, we ensure the viability of the reference electrode by periodically calibrating it in situ using the pH sensor and a standard solution of known pH versus temperature characteristics. The titration data obtained in this study are compared with predictions from EPRI's MULTEQ code, and are found to be in satisfactory agreement in the alkaline pH region. Observed discrepancies in the acidic pH region between the two sets of data are attributed to corrosion of the alloys used to fabricate the titration system

  10. A dipstick sensor for coulometric acid-base titrations

    NARCIS (Netherlands)

    Olthuis, Wouter; van der Schoot, B.H.; Chavez, F.; Bergveld, Piet

    1989-01-01

    By performing an acid-base titration by coulometric generation of OH− or H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in

  11. Using Spreadsheets to Produce Acid-Base Titration Curves.

    Science.gov (United States)

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  12. Determination of Acidity Constants by Gradient Flow-Injection Titration

    Science.gov (United States)

    Conceicao, Antonio C. L.; Minas da Piedade, Manuel E.

    2006-01-01

    A three-hour laboratory experiment, designed for an advanced undergraduate course in instrumental analysis that illustrates the application of the gradient chamber flow-injection titration (GCFIT) method with spectrophotometric detection to determine acidity constants is presented. The procedure involves the use of an acid-base indicator to obtain…

  13. A General Simulator for Acid-Base Titrations

    Science.gov (United States)

    de Levie, Robert

    1999-07-01

    General formal expressions are provided to facilitate the automatic computer calculation of acid-base titration curves of arbitrary mixtures of acids, bases, and salts, without and with activity corrections based on the Davies equation. Explicit relations are also given for the buffer strength of mixtures of acids, bases, and salts.

  14. Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool

    Science.gov (United States)

    Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah

    2018-01-01

    The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…

  15. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    Science.gov (United States)

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  16. Electroconvulsive therapy stimulus titration: Not all it seems.

    Science.gov (United States)

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  17. Evaluation of modified boehm titration methods for use with biochars.

    Science.gov (United States)

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  19. and phenol–formaldehyde resin

    Indian Academy of Sciences (India)

    formaldehyde resin (PFR) modified with tetraethylorthosilicate are investigated in detail. The chemical synthesis of PFR, its modification with nanometer- sized SiO2 particles created by sol–gel method and subsequent coating, enables a preparation of ...

  20. Bending characteristics of resin concretes

    Directory of Open Access Journals (Sweden)

    Ribeiro Maria Cristina Santos

    2003-01-01

    Full Text Available In this research work the influence of composition and curing conditions in bending strength of polyester and epoxy concrete is analyzed. Various mixtures of resin and aggregates were considered in view of an optimal combination. The Taguchi methodology was applied in order to reduce the number of tests, and in order to evaluate the influence of various parameters in concrete properties. This methodology is very useful for the planning of experiments. Test results, analyzed by this methodology, shown that the most significant factors affecting bending strength properties of resin concretes are the type of resin, resin content and charge content. An optimal formulation leading to a maximum bending strength was achieved in terms of material parameters.

  1. Epoxy hydantoins as matrix resins

    Science.gov (United States)

    Weiss, J.

    1983-01-01

    Tensile strength and fracture toughness of castings of the hydantoin resins cured with methylenedianiline are significantly higher than MY 720 control castings. Water absorption of an ethyl, amyl hydantoin formulation is 2.1 percent at equilibrium and Tg's are about 160 C, approximately 15 deg below the final cure temperature. Two series of urethane and ester-extended hydantoin epoxy resins were synthesized to determine the effect of crosslink density and functional groups on properties. Castings cured with methylenedianiline or with hexahydrophthalic anhydride were made from these compounds and evaluated. The glass transition temperatures, tensile strengths and moduli, and fracture toughness values were all much lower than that of the simple hydantoin epoxy resins. Using a methylene bishydantoin epoxy with a more rigid structure gave brittle, low-energy fractures, while a more flexible, ethoxy-extended hydantoin epoxy resin gave a very low Tg.

  2. Resin glycosides from Porana duclouxii.

    Science.gov (United States)

    Ding, Wen-Bing; Zhang, Dai-Gui; Liu, Chun-Jie; Li, Guan-Hua; Li, You-Zhi

    2014-01-01

    A new intact resin glycoside (3) and two glycosidic acids (1 and 2), all having a common trisaccharide moiety and (11S)-hydroxytetradecanoic acid or (3S,11S)-dihydroxytetradecanoic acid as the aglycone, were obtained from the roots of Porana duclouxii. Their structures were elucidated by spectroscopic analyses and chemical correlations. These compounds represent the first examples of resin glycosides from the genus Porana.

  3. Karakteristik Komposit Resin Berkemampuan Mengalir

    Directory of Open Access Journals (Sweden)

    Bambang Irawan

    2015-10-01

    Full Text Available The use of resin composites as posterior restoratives has markedly increased over the past decade. The patients demand for better esthetics, concerns related to possible mercury toxicity from amalgam and improvements in resin composite materials have significantly contributed the popularity of these materials. Early problems related to composites included excessive wear, less of anatomic form, post operative sensitivity, secondary caries and marginal leakage. Marginal adaptation still remains an unavoidable problem for composite restoration, especially at the gingival wall of cervical or Class II restoration. In an attempt to improve marginal sealing, many techniques and lining materials have been designed. To reduce stress generated by polymerization shrinkage, applying and curing of resin composites in layers is often recommended. Using a thick adhesive layer or low-viscosity resin may, due to its elastic properties, serve as a flexible intermediate layer and compensate for the polymerization stress created in resin composite. Flowable composites were created by retaining the same small particle size of traditional hybrid composite but reducing the filler content and allowing the increased resin to reduce the viscosity of the mixture. Flowable composites were introduced in 1996 as liners, fissure sealants and also in tunnel preparations. They have been suggested for Class I, II, III and V cavity restorations, preventive resin restorations and composite, porcelain and amalgam repairing. Their usage as a liner under high filled resins in posterior restorations has been shown to improve the adaptation of composites and effectively achieve clinically acceptable results. This article attempts to give a broad characteristics of different types of flowable composites. 

  4. Liquid monobenzoxazine based resin system

    Science.gov (United States)

    Tietze, Roger; Nguyen, Yen-Loan; Bryant, Mark

    2014-10-07

    The present invention provides a liquid resin system including a liquid monobenzoxazine monomer and a non-glycidyl epoxy compound, wherein the weight ratio of the monobenzoxazine monomer to the non-glycidyl epoxy compound is in a range of about 25:75 to about 60:40. The liquid resin system exhibits a low viscosity and exceptional stability over an extended period of time making its use in a variety of composite manufacturing methods highly advantageous.

  5. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  6. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  7. Colloid Titration--A Rapid Method for the Determination of Charged Colloid.

    Science.gov (United States)

    Ueno, Keihei; Kina, Ken'yu

    1985-01-01

    "Colloid titration" is a volumetric method for determining charged polyelectrolytes in aqueous solutions. The principle of colloid titration, reagents used in the procedure, methods of endpoint detection, preparation of reagent solutions, general procedure used, results obtained, and pH profile of colloid titration are considered. (JN)

  8. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    Science.gov (United States)

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  9. Acidity titration curves - a versatile tool for the characterisation of acidic mine waste water

    International Nuclear Information System (INIS)

    Fyson, A.

    2000-01-01

    Acidity titrations with NaOH are valuable tools for characterisation of acidic mine waters. - Titrations can be used to estimate metal concentrations. - Titrations can be carried out in the field, minimising changes in water chemistry due to sample handling time and procedure. (orig.)

  10. Mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists); Mammadiagnostik fuer MTRA/RT

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann

    2014-07-01

    The text book on mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists) covers the following issues: Anatomy, development and physiology of mammary glands; tumor development an breast cancer risk; pathology, non-imaging diagnostics; mammography: physical-technical fundamentals; mammography: analogue technique; mammography: digital technique; mammography: quality assurance; mammography: legal questions and radiation protection; mammography: new developments; mammography: setting technique; mammography: use and appraisal; mamma-sonography: technique and methodology; mamma-sonography: assignment and appraisal, mamma-NMR: technique and methodology; mamma-NMR: assignment and appraisal lymph node diagnostics; mamma interventions; biopsy; mamma interventions: marking examination concepts; therapeutic concepts; hygienic concepts; communication and interaction.

  11. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  12. Analysis of the Purity of Cetrimide by Titrations

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Nielsen, Hans/Boye

    2006-01-01

    The purity of cetrimide, trimethyl tetradecyl ammonium bromide (TTAB), that is an important preservative of many cosmetic and pharmaceutical products, was determined by three independent methods of titration. Traditionally, cetrimide was analysed by an assay method of the European Pharmacopoeia (Ph...... the extraction step of the Ph. Eur.-assay method. The distribution coefficients between chloroform and water of cetrimide and the corresponding iodide species (TTAI) were thus determined as 2150 ± 50 M-1 and 68000 ± 4000 M-1, respectively....

  13. Interaction of molybdenum (6) with potassium benzyldithiocarbaminate during amperometric titration

    International Nuclear Information System (INIS)

    Galushko, S.V.; Usatenko, Yu.I.

    1975-01-01

    The paper is an amperometric study of the mechanism of interaction between molybdenum (VI) and potassium benzyl dithiocarbamate [BDTC] which was based on the use of voltamperometry, electron paramagnetic resonance, infrared spectroscopy, potentiometry and elemental analysis. In amperometric titration Mo(VI) with BDTC (pH 4-2) forms a red compound of low solubility. In more acidic media the intensity of coloration is increased and a violet hue develops. On the basis of the data obtained it is concluded that in the amperometric titration of Mo(VI) with potassium BDTC there is first formation of a Mo(VI) compound, which subsequently acquires a red colour as a result of the reduction of Mo(VI) to Mo(V). It was also established that the degree of reduction is small where titration is carried out in the range pH 4.8-0.1. Quantitative determination of Mo is performed most effectively in slightly acidic media. Mo reacts with potassium BDTC in a ratio of 1:2. (E.P.)

  14. Cell titration assay for measuring blastogenesis of bovine lymphocytes.

    Science.gov (United States)

    Baldwin, C L; Antczak, D F; Winter, A J

    1985-08-01

    The blastogenic response of bovine peripheral blood lymphocytes to phytohemagglutinin (PHA) and to microbial antigens was measured using a lymphocyte titration assay. Culture conditions, including lymphocyte concentrations, incubation periods and medium formulation, were established which produced linear or nearly linear responses over a range of cell concentrations. These conditions were established by testing lymphocytes from unimmunized cattle and from heifers infected with Brucella abortus with PHA and a B. abortus extract. Four cell concentrations in 2-fold increments were selected for measuring responses to PHA (3.125 X 10(3) to 2.5 X 10(4) cells/well) and to antigens (5.0 X 10(4) to 4.0 X 10(5) cells/well). The strength of response varied among animals and also over time for individual animals, but the titration assay allowed exponential proliferation to be distinguished from decline, which may have been due to overcrowding of microtiter wells, exhaustion of nutrients or induction of regulatory events. This assay provided a more reliable and discriminating method of evaluating lymphocyte proliferation responses than that achieved by single point assays. The displacement of the titration curves could be used to estimate the relative frequency of lymphocytes responding to antigens or mitogens.

  15. Titratable acidity of beverages influences salivary pH recovery.

    Science.gov (United States)

    Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido

    2015-01-01

    A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  16. A rapid method for titration of ascovirus infectivity.

    Science.gov (United States)

    Han, Ningning; Chen, Zishu; Wan, Hu; Huang, Guohua; Li, Jianhong; Jin, Byung Rae

    2018-05-01

    Ascoviruses are a recently described family and the traditional plaque assay and end-point PCR assay have been used for their titration. However, these two methods are time-consuming and inaccurate to titrate ascoviruses. In the present study, a quick method for the determination of the titer of ascovirus stocks was developed based on ascovirus-induced apoptosis in infected insect cells. Briefly, cells infected with serial dilutions of virus (10 -2 -10 -10 ) for 24 h were stained with trypan blue. The stained cells were counted, and the percentage of nonviable cells was calculated. The stained cell rate was compared between virus-infected and control cells. The minimum-dilution group that had a significant difference compared with control and the maximum-dilution group that had no significant difference were selected and then compared each well of the two groups with the average stained cell rate of control. The well was marked as positive well if the stained cell rate was higher than the average stained cell rate of control wells; otherwise, the well was marked as negative wells. The percentage of positive wells were calculated according to the number of positive. Subsequently, the virus titer was calculated through the method of Reed and Muench. This novel method is rapid, simple, reproducible, accurate, and less material-consuming and eliminates the subjectivity of the other procedures for titrating ascoviruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Reverse transcriptase-quantitative polymerase chain reaction (RT ...

    African Journals Online (AJOL)

    The reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is a highly specific polymerase chain reaction (PCR) method that allows one to detect very low transcription levels of functional gene(s) in soil. RT-qPCR helps us to know the active members of the microbial community, and their activities can be ...

  18. Resin technologies: construction and staining of resin TMA's.

    Science.gov (United States)

    Howat, William J; Wilson, Susan J

    2010-01-01

    The traditional formaldehyde-fixed paraffin-embedded tissue, and therefore the tissue microarrays created from it, provide good morphology but with a compromised antigenicity when compared to frozen tissue. In contrast, while solving the issue of antigenicity, frozen tissue suffers from a lack of morphology. We have demonstrated that tissue microarrays constructed in glycol methacrylate resin, when combined with a cold acetone fixation step, have been able to combine the superior morphology of resin-embedded sections with the superior antigenicity of frozen tissue for prospectively collected material.

  19. Epoxy Resins in Electron Microscopy

    Science.gov (United States)

    Finck, Henry

    1960-01-01

    A method of embedding biological specimens in araldite 502 (Ciba) has been developed for materials available in the United States. Araldite-embedded tissues are suitable for electron microscopy, but the cutting qualities of the resin necessitates more than routine attention during microtomy. The rather high viscosity of araldite 502 also seems to be an unnecessary handicap. The less viscous epoxy epon 812 (Shell) produces specimens with improved cutting qualities, and has several features—low shrinkage and absence of specimen damage during cure, minimal compression of sections, relative absence of electron beam-induced section damage, etc.—which recommends it as a routine embedding material. The hardness of the cured resin can be easily adjusted by several methods to suit the materials embedded in it. Several problems and advantages of working with sections of epoxy resins are also discussed. PMID:13822825

  20. Process for Molding Nonreinforced (Neat) Resins

    Science.gov (United States)

    Dickerson, G. E.

    1983-01-01

    Void free moldings obtained for neat, condensation, thermosetting resins. Thermally and mechanically treat resin prior to molding to reduce amount of volatiles. With volatiles reduced molding temperature and pressure are applied in way to drive out remaining volatiles during molding.

  1. 21 CFR 172.280 - Terpene resin.

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION (CONTINUED) FOOD ADDITIVES PERMITTED FOR DIRECT ADDITION TO FOOD FOR HUMAN CONSUMPTION Coatings, Films and Related Substances § 172.280 Terpene resin. The food additive terpene resin may be safely used...

  2. Action of ionizing radiation on epoxy resins

    Energy Technology Data Exchange (ETDEWEB)

    Van de Voorde, M. E.

    1970-12-01

    The resistance of classical and experimental epoxy resins to irradiation was studied. The resistance to irradiation of epoxy resins of diverse compositions as well as the development of resins having a radioresistance that approaches that of certain ceramics are discussed. Sources of irradiation and the techniques of dosimetry used are described. The structures of certain epoxy resins and of hardeners are given. The preparation of these resins and their physical properties is described. The effects of radiation on epoxy resins, as well as conditions of irradiation, and suggested mechanisms for degradation of the irradiated resins are discussed. The relationship between chemical structure of the resins and their physical properties is evaluated. (115 references) (JCB)

  3. Synthesis and characterization of carboxylic cation exchange bio-resin for heavy metal remediation.

    Science.gov (United States)

    Kulkarni, Vihangraj V; Golder, Animes Kumar; Ghosh, Pranab Kumar

    2018-01-05

    A new carboxylic bio-resin was synthesized from raw arecanut husk through mercerization and ethylenediaminetetraacetic dianhydride (EDTAD) carboxylation. The synthesized bio-resin was characterized using thermogravimetric analysis, field emission scanning electron microscopy, proximate & ultimate analyses, mass percent gain/loss, potentiometric titrations, and Fourier transform infrared spectroscopy. Mercerization extracted lignin from the vesicles on the husk and EDTAD was ridged in to, through an acylation reaction in dimethylformamide media. The reaction induced carboxylic groups as high as 0.735mM/g and a cation exchange capacity of 2.01meq/g functionalized mercerized husk (FMH). Potentiometric titration data were fitted to a newly developed single-site proton adsorption model (PAM) that gave pKa of 3.29 and carboxylic groups concentration of 0.741mM/g. FMH showed 99% efficiency in Pb(II) removal from synthetic wastewater (initial concentration 0.157mM), for which the Pb(II) binding constant was 1.73×10 3 L/mol as estimated from modified PAM. The exhaustion capacity was estimated to be 18.7mg/g of FMH. Desorption efficiency of Pb(II) from exhausted FMH was found to be about 97% with 0.1N HCl. The FMH simultaneously removed lead and cadmium below detection limit from a real lead acid battery wastewater along with the removal of Fe, Mg, Ni, and Co. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Method for loading resin beds

    International Nuclear Information System (INIS)

    Notz, K.J.; Rainey, R.H.; Greene, C.W.; Shockley, W.E.

    1978-01-01

    An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145 to 200 0 C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145 0 C with a second aqueous component to provide a gaseous phase containing HNO 3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate

  5. Uranium sorption by tannin resins

    International Nuclear Information System (INIS)

    Olivares Rieumont, S.; Martinez Luzardo, J.; Torres Hernandez, J.; Lima Cazorla, D. de la Rosa.

    1998-01-01

    The sorption of uranium by immobilised Eucalyptus Saligna Sm. and Lysiloma latisiliqua L tannins was investigated. Immobilization condition were analyzed. These resins resulted suitable adsorbent for the concentration of uranium from aqueous systems. The sorption of uranium is pH dependent. At pH 5.5 maximum in sorption capacity is registered. The presence of appreciable amount of sodium chloride do not have any effect on uranium removal. Carbonate and calcium ions in concentrations similar to these that could be found in sea water and other natural water do not decrease the uranium uptake. Tannin resins can be used several times without an appreciable decay of their sorption capacity

  6. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  7. Ion Exchange Testing with SRF Resin FY 2012

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Rinehart, Donald E.; Peterson, Reid A.

    2014-07-02

    Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.01, which was prepared and approved in response to the Test Specification 24590-PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590-PTF-TEF-RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

  8. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert, George W. (Harrisonville, MO); Hand, Thomas E. (Lee' s Summit, MO); DeLaurentiis, Gary M. (Jamestown, CA)

    2008-11-18

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  9. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert,George W. (Harrisonville, MO); Hand,Thomas E. (Lee' s Summit, MO); Delaurentiis,Gary M. (Jamestown, CA)

    2007-08-07

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  10. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-12-30

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  11. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    Science.gov (United States)

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  12. Characterization of Sea Lettuce Surface Functional Groups by Potentiometric Titrations

    Science.gov (United States)

    Ebling, A. M.; Schijf, J.

    2008-12-01

    In pursuit of our ultimate goal to better understand the prodigious capacity of the marine macroalga Ulva lactuca (sea lettuce) for adsorbing a broad range of dissolved trace metals from seawater, we performed an initial characterization of its surface functional groups. Specifically, the number of distinct functional groups as well as their individual bulk concentrations and acid dissociation constants (pKas) were determined by potentiometric titrations in NaCl solutions of various ionic strengths (I = 0.01-5.0 M), under inert nitrogen atmosphere at 25°C. Depending on the ionic strength, Ulva samples were manually titrated down to pH 2 or 3 with 1 N HCl and then up to pH 10 with 1 N NaOH in steps of 0.1-0.2 units, continuously monitoring pH with a glass combination electrode. Titrations of a dehydrated Ulva standard reference material (BCR-279) were compared with fresh Ulva tissue cultured in our laboratory. A titration in filtered natural seawater was also compared with one in an NaCl solution of equal ionic strength. Equilibrium constants for the ionization of water in NaCl solutions as a function of ionic strength were obtained from the literature. Fits to the titration data ([H]T vs. pH) were performed with the FITEQL4.0 computer code using non-electrostatic 3-, 4-, and 5-site models, either by fixing ionic strength at its experimental value or by allowing it to be extrapolated to zero, while considering all functional group pKas and bulk concentrations as adjustable parameters. Since pKas and bulk concentrations were found to be strongly correlated, the latter were also fixed in some cases to further constrain the pKas. Whereas these calculations are currently ongoing, preliminary results point to three, possibly four, functional groups with pKas of about 4.1, 6.3, and 9.5 at I = 0. Bulk concentrations of the three groups are very similar, about 5-6×10-4 mol/g based on dry weight, which suggests that all are homogeneously distributed over the surface and

  13. Diterpene resin acids in conifers.

    Science.gov (United States)

    Keeling, Christopher I; Bohlmann, Jörg

    2006-11-01

    Diterpene resin acids are a significant component of conifer oleoresin, which is a viscous mixture of terpenoids present constitutively or inducibly upon herbivore or pathogen attack and comprises one form of chemical resistance to such attacks. This review focuses on the recent discoveries in the chemistry, biosynthesis, molecular biology, regulation, and biology of these compounds in conifers.

  14. Occupational exposure to epoxy resins

    NARCIS (Netherlands)

    Terwoert, J.; Kersting, K.

    2014-01-01

    Products based on epoxy resins as a binder have become popular in various settings, among which the construction industry and in windmill blade production, as a result of their excellent technical properties. However, due to the same properties epoxy products are a notorious cause of allergic skin

  15. Titratable acidity of beverages influences salivary pH recovery

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló TENUTA

    2015-01-01

    Full Text Available A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively. Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  16. Modelling of acid-base titration curves of mineral assemblages

    Directory of Open Access Journals (Sweden)

    Stamberg Karel

    2016-01-01

    Full Text Available The modelling of acid-base titration curves of mineral assemblages was studied with respect to basic parameters of their surface sites to be obtained. The known modelling approaches, component additivity (CA and generalized composite (GC, and three types of different assemblages (fucoidic sandstones, sedimentary rock-clay and bentonite-magnetite samples were used. In contrary to GC-approach, application of which was without difficulties, the problem of CA-one consisted in the credibility and accessibility of the parameters characterizing the individual mineralogical components.

  17. Specific Interaction between eEF1A and HIV RT Is Critical for HIV-1 Reverse Transcription and a Potential Anti-HIV Target.

    Directory of Open Access Journals (Sweden)

    Dongsheng Li

    2015-12-01

    Full Text Available Reverse transcription is the central defining feature of HIV-1 replication. We previously reported that the cellular eukaryotic elongation factor 1 (eEF1 complex associates with the HIV-1 reverse transcription complex (RTC and the association is important for late steps of reverse transcription. Here we show that association between the eEF1 and RTC complexes occurs by a strong and direct interaction between the subunit eEF1A and reverse transcriptase (RT. Using biolayer interferometry and co-immunoprecipitation (co-IP assays, we show that association between the eEF1 and RTC complexes occurs by a strong (KD ~3-4 nM and direct interaction between eEF1A and reverse transcriptase (RT. Biolayer interferometry analysis of cell lysates with titrated levels of eEF1A indicates it is a predominant cellular RT binding protein. Both the RT thumb and connection domains are required for interaction with eEF1A. A single amino acid mutation, W252A, within the thumb domain impaired co-IP between eEF1A and RT, and also significantly reduced the efficiency of late reverse transcription and virus replication when incorporated into infectious HIV-1. Molecular modeling analysis indicated that interaction between W252 and L303 are important for RT structure, and their mutation to alanine did not impair heterodimerisation, but negatively impacted interaction with eEF1A. Didemnin B, which specifically binds eEF1A, potently inhibited HIV-1 reverse transcription by greater than 2 logs at subnanomolar concentrations, especially affecting reverse transcription late DNA synthesis. Analysis showed reduced levels of RTCs from HIV-1-infected HEK293T treated with didemnin B compared to untreated cells. Interestingly, HIV-1 with a W252A RT mutation was resistant to didemnin B negative effects showing that didemnin B affects HIV-1 by targeting the RT-eEF1A interaction. The combined evidence indicates a direct interaction between eEF1A and RT is crucial for HIV reverse

  18. rt, Arvo: "Beatus". Statuit ei Dominus / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1997-01-01

    Uuest heliplaadist "Pärt, Arvo: "Beatus". Statuit ei Dominus. Missa syllabica. Beatus Petronius. 7 Magnificat-Antiphonen. De profundis. Memento. Cantate Domino. Solfeggio. Estonian Philharmonic Chamber Choir, T. Kaljuste". Virgin Classics 545 276-2 (CD:167F)

  19. rt, Arvo: "Miserere", "Festina lente" / Volkmar Fischer

    Index Scriptorium Estoniae

    Fischer, Volkmar

    1991-01-01

    Uuest heliplaadist Pärt, Arvo: "Miserere", "Festina lente", "Sarah Was Ninety Years Old". The Hilliard Ensemble. Orchester der Beethovenhalle Bonn. Dirigent Dennis Russel Davies (ECM Records, distr Amigo)

  20. rt, Arvo. Litany; Psalom; Trisagion / Andreas Obst

    Index Scriptorium Estoniae

    Obst, Andreas

    1996-01-01

    rt, Arvo. Litany; Psalom; Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste; Lithuanian Chamber Orchestra, Saulius Sondeckis. ECM 1592/449 810-2

  1. rt, Arvo: Litany. Psalom. Trisagion / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: Litany. Psalom. Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste; Lithuanian Chamber Orchestra, Saulius Sondeckis" ECM New Series 449 810-4; 449 810-2 (42 minutes: DDD)

  2. rt, Arvo: Seven Magnificat Antiphons / Barry Witherden

    Index Scriptorium Estoniae

    Witherden, Barry

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: Seven Magnificat Antiphons. Magnificat. Summa; Tormis, Veljo: The Curse Upon Iron. Karelian Destiny. BBC Singers, Bo Holton". Collins Classics 1472-2 (61 minutes: DDD)

  3. Milan Kundera poeediparukaga faun / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    1996-01-01

    Arvustus: Kundera, Milan. Surematus. Tln. : Monokkel, 1995. Ilmunud ka kogumikus: Hellerma, Kärt. Kohanenud kirjandus : valik kirjanduskriitikat 1987-2006. Eesti Keele Sihtasutus : Tallinn, 2006. Lk. 176-179

  4. Kuidas sünnib pealkiri? / Pärt Lias

    Index Scriptorium Estoniae

    Lias, Pärt

    2003-01-01

    Eesti kirjanikud vastavad Pärt Liase küsimusele oma teoste pealkirjade saamisloo kohta: Doris Kareva, Ilona Laaman, Eha Lättemäe, Priidu Beier, Oskar Kruus, Jaan Kruusvall, Paul-Eerik Rummo ja Andres Vanapa (1); Triin Soomets, Priit Aimla, Aarne Puu, Einar Sander, Jüri Tuulik ja Ülo Tuulik (2); Nikolai Baturin, Leo Metsar, Toomas Vint, Leonid Stolovitš ja Pärt Lias (3)

  5. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    Directory of Open Access Journals (Sweden)

    Lorentz JÄNTSCHI

    2002-12-01

    Full Text Available The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titrations/v1.1/ The method allows expressing the value of pH in any point of titration process and permits to observe the equivalence point of titration.

  6. Comparison of VFA titration procedures used for monitoring the biogas process

    DEFF Research Database (Denmark)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng

    2014-01-01

    titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic...... (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40mL of four times diluted digested manure was gently stirred (200rpm). Results from samples with different VFA...... concentrations (1-11g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1g/L. The accuracy of titration increased when...

  7. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.

  8. Understanding watershed hydrogeochemistry: 1. Development of RT-Flux-PIHM

    Science.gov (United States)

    Bao, Chen; Li, Li; Shi, Yuning; Duffy, Christopher

    2017-03-01

    Model development in hydrology and geochemistry has been advancing separately with limited integration. We developed a watershed hydrogeochemical code RT-Flux-PIHM to understand complex interactions between hydrological processes (PIHM), land-surface processes (FLUX—Noah Land Surface Model), and multicomponent subsurface reactive transport (RT). The RT module simulates geochemical processes including aqueous complexation, surface complexation, mineral dissolution and precipitation, and cation exchange. The RT module is verified against the widely used reactive transport code CrunchFlow. The code uses semidiscrete finite volume method and irregular gridding and offers data harvesting capabilities from national databases. The application of RT-Flux-PIHM is demonstrated in the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO). We aim to understand key processes that govern hydrogeochemical dynamics of the nonreactive chloride and reactive magnesium. Simulation results indicate that watershed characteristics, in particular topography, dictate the spatial distributions of water content and soil dissolution rates. Ion exchange provides buffering capacities and leads to a hysteresis loop of concentration and discharge relationship of magnesium, which differs from the open hysteresis of chloride. RT-Flux-PIHM offers physics-based modeling capabilities to integrate the vast amount of water and chemistry data that have now become available, to differentiate the relative importance of competing processes, and to test hypotheses at the interface of hydrology and geochemistry.

  9. Hyperthermic Fibrinolysis with rt-PA: In Vitro Results

    International Nuclear Information System (INIS)

    Schwarzenberg, Helmut; Mueller-Huelsbeck, Stefan; Brossman, Joachim; Christian Glueer, Claus; Bruhn, Hans Dieter; Heller, Martin

    1998-01-01

    Purpose: To investigate the influence of hyperthermia up to 45 deg. C on fibrinolysis with recombinant tissue-type plasminogen activator (rt-PA). Methods: Standardized fibrin clots were incubated in a water bath for 5 hr with either rt-PA (test group) or 0.9% sodium chloride (control group) and blood plasma at temperatures of 30-45 deg. C. Concentrations of D-dimer and time to complete clot lysis were measured.Results: The activity of fibrinolysis with rt-PA rose with increasing temperature: time to lysis approximately halved from 30 deg. C to 40 deg. C and the concentration of D-dimer tripled. In the control group clot size did not change.Conclusions: Activity of rt-PA-induced fibrinolysis rises distinctly with higher temperatures. Since even healthy subjects show a physiologic decline in body temperature in the extremities, in patients with occlusive arterial disease decreased activity of fibrinolysis with rt-PA can be expected. Controlled hyperthermia may improve fibrinolysis with rt-PA and should be investigated in vivo

  10. EDF specifications on nuclear grade resins

    International Nuclear Information System (INIS)

    Mascarenhas, Darren; Gressier, Frederic; Taunier, Stephane; Le-Calvar, Marc; Ranchoux, Gilles; Marteau, Herve; Labed, Veronique

    2012-09-01

    Ion exchange resins are widely used across EDF, especially within the nuclear division for the purification of water. Important applications include primary circuit, secondary circuit and effluent treatment, which require high quality nuclear grade resins to retain the dissolved species, some of which may be radioactive. There is a need for more and more efficient purification in order to decrease worker dose during maintenance but also to decrease volumes of radioactive resin waste. Resin performance is subject to several forms of degradation, including physical, chemical, thermal and radioactive, therefore appropriate resin properties have to be selected to reduce such effects. Work has been done with research institutes, manufacturers and on EDF sites to select these properties, create specifications and to continuously improve on these specifications. An interesting example of research regarding resin performance is the resin degradation under irradiation. Resins used in the CVCS circuit of EDF nuclear power plants are subject to irradiation over their lifetime. A study was carried out on the effects of total integrated doses of 0.1, 1 and 10 MGy on typically used EDF mixed bed resins in a 'mini-CVCS' apparatus to simultaneously test actual primary circuit fluid. The tests confirmed that the resins still perform efficiently after a typical CVCS radiation dose. Certain resins also need additional specifications in order to maintain the integrity of the particular circuits they are used in. Recently, EDF has updated its requirements on these high purity nuclear grade resins, produced generic doctrines for all products and materials used on site which include resins of all grades, and as a result have also updated a guide on recommended resin usage for the French fleet of reactors. An overview of the evolutions will be presented. (authors)

  11. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  12. Potentiometric titration of molybdenum (6) with a cathode-polarized solid electrode

    International Nuclear Information System (INIS)

    Boeva, L.V.; Kimstach, V.A.; Bagdasarov, K.N.

    1980-01-01

    The possibility has been studied of using solid electrodes for potentiometric precipitation titration of molybdenum (6). A cathode-polarized electrode, electrochemically covered with a molybdenum blue layer, can be used as indicator electrode. The best results were obtained during deposition of molybdenum blue on a tungsten electrode. The mechanism of electrode work during titration has been investigated. A procedure has been developed of titration of molybdenum (6) in acid solutions using hydroxylamine N-aryl derivatives as titrants

  13. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    OpenAIRE

    Jian-Qiang Hu; Jian-Jian Zhang; Shi-Zhao Yang; Yong-Liang Xin; Li Guo; Ting Yao

    2017-01-01

    Water content in jet fuels is detected by thermometric titration (TMT), and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicate...

  14. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    OpenAIRE

    Eva Tavčar; Erika Turk; Samo Kreft

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes p...

  15. Fast Proton Titration Scheme for Multiscale Modeling of Protein Solutions.

    Science.gov (United States)

    Teixeira, Andre Azevedo Reis; Lund, Mikael; da Silva, Fernando Luís Barroso

    2010-10-12

    Proton exchange between titratable amino acid residues and the surrounding solution gives rise to exciting electric processes in proteins. We present a proton titration scheme for studying acid-base equilibria in Metropolis Monte Carlo simulations where salt is treated at the Debye-Hückel level. The method, rooted in the Kirkwood model of impenetrable spheres, is applied on the three milk proteins α-lactalbumin, β-lactoglobulin, and lactoferrin, for which we investigate the net-charge, molecular dipole moment, and charge capacitance. Over a wide range of pH and salt conditions, excellent agreement is found with more elaborate simulations where salt is explicitly included. The implicit salt scheme is orders of magnitude faster than the explicit analog and allows for transparent interpretation of physical mechanisms. It is shown how the method can be expanded to multiscale modeling of aqueous salt solutions of many biomolecules with nonstatic charge distributions. Important examples are protein-protein aggregation, protein-polyelectrolyte complexation, and protein-membrane association.

  16. Semi-automated potentiometric titration method for uranium characterization

    Energy Technology Data Exchange (ETDEWEB)

    Cristiano, B.F.G., E-mail: barbara@ird.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Delgado, J.U.; Silva, J.W.S. da; Barros, P.D. de; Araujo, R.M.S. de [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear (PEN/COPPE), Universidade Federal do Rio de Janeiro (UFRJ), Ilha do Fundao, PO Box 68509, Rio de Janeiro, 21945-970 RJ (Brazil)

    2012-07-15

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. - Highlights: Black-Right-Pointing-Pointer We developed a semi-automatic version of potentiometric titration method. Black-Right-Pointing-Pointer The method is used for certification and characterization of uranium compounds. Black-Right-Pointing-Pointer The traceability of the method was assured by a K{sub 2}Cr{sub 2}O{sub 7} primary standard. Black-Right-Pointing-Pointer The results of U{sub 3}O{sub 8} reference material analyzed was consistent with certified value. Black-Right-Pointing-Pointer The uncertainty obtained, near 0.01%, is useful for characterization purposes.

  17. Common Standards of Basal Insulin Titration in T2DM

    Science.gov (United States)

    Arnolds, Sabine; Heise, Tim; Flacke, Frank; Sieber, Jochen

    2013-01-01

    Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter, however, might have time constraints and have to deal with many kinds of diseases or with multimorbid patients, so their focus is not so much on lowering high blood glucose values. Thus, the physicians, as well as the patients themselves, are often reluctant to initiate and adjust insulin therapy, although basal insulin therapy is considered the appropriate strategy after oral antidiabetic drug failure, according to the latest international guidelines. A substantial number of clinical studies have shown that insulin initiation and optimization can be managed successfully by using titration algorithms—even in cases where patients themselves are the drivers of insulin titration. Nevertheless, tools and strategies are needed to facilitate this process in the daily life of both primary health care professionals and patients with diabetes. PMID:23759411

  18. Radiometric titration of thallium(III) with EDTA

    International Nuclear Information System (INIS)

    Rao, V.R.S.; Pulla Rao, Ch.; Tataiah, G.

    1978-01-01

    Radioactive solutions containing very small amounts of thallium(III) can be determined by radiometric titration using ammonia as hydrolysing agent. Aqueous solution of thallium(I) (both inactive and radioactive) is treated with bromine water till the appearance of the brown colour of bromine, and the solution is warmed to 80 deg C to expel the excess bromine. By this procedure all thallium(I) is quantitatively oxidised to thallium(III). An aqueous solution of ammonia is added to precipitate thallium(III) as thallic oxide. It is then filtered, washed with water to free it from bromide and then dissolved in 2N HCl and the solution is then standardised. 2 ml of this solution is transferred to a 20 ml volumetric flask, 1 ml of radioactive thallium(III) solution to be standardised is added as well as incremental amounts of EDTA solution and mixed thoroughly. Uncomplexed thallium(III) is then precipitated by the addition of an ammonia solution and diluted to 20 ml. Required amount of this mixture is centrifuged. The beta activity of the supernatant aliquot is measured using a GM counter. Quantitative determination of Tl(III) in the range of 1-10 μM can be carried out. The interference of cations such as Au(III), iron(III), Ga(III) can be eliminated by pretreatment of the Tl(III) solution before carrying out radiometric titration. The results obtained are reproducible and accurate to +-3%. (T.I.)

  19. Ruthenium determination in new composite materials by coulometric titration with generated iron(2)

    International Nuclear Information System (INIS)

    Butakova, N.A.; Oganesyan, L.B.

    1983-01-01

    A coulometric technique is developed for ruthenium (4) titration with generated iron (2) in a mixture of hydrochloric-, sulfuric- and phosphoric acids with potentiometric and biammetric indication of the final titration point. Bi (3), Pd (2), Nb (5), Pt (4) Pb (2), Rh (3) do not interfere with the titration. Together with Ru (4) titrated are Ir (4), V (5), Au (3). The method is applied to analyze commercial samples of ruthenium dioxides, lead- and bismuth ruthenites, ruthenium pentafluorides containing 30-80% of ruthenium. The Ssub(r) values do not exceed 0.002

  20. The role of titration schedule of topiramate for the development of depression in patients with epilepsy.

    Science.gov (United States)

    Mula, Marco; Hesdorffer, Dale C; Trimble, Michael; Sander, Josemir W

    2009-05-01

    To determine whether a fast titration schedule of topiramate (TPM) has different effects on the occurrence of depression, in relation to other risk factors for TPM-induced depression, including history of depression (HxDEP), febrile seizures (FS), and hippocampal sclerosis (HS). Using data from a large case registry of patients prescribed TPM, two models were constructed: Model 1 examined the independent effect of rapid TPM titration after separate adjustment for FS, HxDEP, and HS. Model 2 examined effect of the cooccurrence of rapid titration on the development of depression with each of these risk factors. A total of 423 patients were included (51.8% females), mean age (SD) 35.5 (11.8) years, mean duration of epilepsy of 22.2 (11.5) years. Forty-four patients (10.4%) developed depression during TPM therapy. A rapid TPM titration was associated with 5-fold increased risk of depression that increased to 12.7-fold in the presence of both FS and rapid TPM titration, 23.3-fold in the presence of both HxDEP and rapid TPM titration, and 7.6-fold in the presence of both HS and rapid TPM titration schedule. Our study suggests that a rapid titration schedule is associated with an increased risk of developing depression during TPM therapy. HxDEP and FS are major contraindications to the use of a rapid titration, with a 23.3-fold and 12.7 fold increased risk, respectively.

  1. Method for linearizing the potentiometric curves of precipitation titration in nonaqueous and aqueous-organic solutions

    International Nuclear Information System (INIS)

    Bykova, L.N.; Chesnokova, O.Ya.; Orlova, M.V.

    1995-01-01

    The method for linearizing the potentiometric curves of precipitation titration is studied for its application in the determination of halide ions (Cl - , Br - , I - ) in dimethylacetamide, dimethylformamide, in which titration is complicated by additional equilibrium processes. It is found that the method of linearization permits the determination of the titrant volume at the end point of titration to high accuracy in the case of titration curves without a potential jump in the proximity of the equivalent point (5 x 10 -5 M). 3 refs., 2 figs., 3 tabs

  2. Application of »Mass Titration« to Determination of Surface Charge of Metal Oxides

    OpenAIRE

    1998-01-01

    The mass titration method, used for the point of zero charge determination, was extended to the measurement of the surface charge density. The results agree with the common method, which is the acid-base titration of the colloidal suspension. The advantage of mass titration is that one does not need to perform blank titration, instead one simply adds metal oxide powder to the electrolyte aqueous solution of known pH. To cover the pH range above and below the point of zero charge, two experime...

  3. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  4. NASA SPoRT GOES-R Proving Ground Activities

    Science.gov (United States)

    Stano, Geoffrey T.; Fuell, Kevin K.; Jedloec, Gary J.

    2010-01-01

    The NASA Short-term Prediction Research and Transition (SPoRT) program is a partner with the GOES-R Proving Ground (PG) helping prepare forecasters understand the unique products to come from the GOES-R instrument suite. SPoRT is working collaboratively with other members of the GOES-R PG team and Algorithm Working Group (AWG) scientists to develop and disseminate a suite of proxy products that address specific forecast problems for the WFOs, Regional and National Support Centers, and other NOAA users. These products draw on SPoRT s expertise with the transition and evaluation of products into operations from the MODIS instrument and the North Alabama Lightning Mapping Array (NALMA). The MODIS instrument serves as an excellent proxy for the Advanced Baseline Imager (ABI) that will be aboard GOES-R. SPoRT has transitioned and evaluated several multi-channel MODIS products. The true and false color products are being used in natural hazard detection by several SPoRT partners to provide better observation of land features, such as fires, smoke plumes, and snow cover. Additionally, many of SPoRT s partners are coastal offices and already benefit from the MODIS sea surface temperature composite. This, along with other surface feature observations will be developed into ABI proxy products for diagnostic use in the forecast process as well as assimilation into forecast models. In addition to the MODIS instrument, the NALMA has proven very valuable to WFOs with access to these total lightning data. These data provide situational awareness and enhanced warning decision making to improve lead times for severe thunderstorm and tornado warnings. One effort by SPoRT scientists includes a lightning threat product to create short-term model forecasts of lightning activity. Additionally, SPoRT is working with the AWG to create GLM proxy data from several of the ground based total lightning networks, such as the NALMA. The evaluation will focus on the vastly improved spatial

  5. Foam, Foam-resin composite and method of making a foam-resin composite

    Science.gov (United States)

    Cranston, John A. (Inventor); MacArthur, Doug E. (Inventor)

    1995-01-01

    This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.

  6. Synthesis of Hydrophobic, Crosslinkable Resins.

    Science.gov (United States)

    1984-12-01

    Bismaleimides have also been crosslinked with radical initiators to produce brittle networks [4].If a damine is added, chain extension and radical crosslinkinq...are produced during cure.The company also produced a similar phenylene based resin, with pendant nitrile groups which could be crosslinked without the...benzenes and tetra substituted cyclopentadienones [881. g. Preparation of poly 1,4 phenylene by nickel (0> catalysed electropolymerisation 1891. Cont’d

  7. Titration curves: a useful instrument for assessing the buffer systems of acidic mining waters.

    Science.gov (United States)

    Totsche, Oliver; Fyson, Andrew; Kalin, Margarete; Steinberg, Christian E W

    2006-07-01

    The acidification of mine waters is generally caused by metal sulfide oxidation, related to mining activities. These waters are characterized by low pH and high acidity due to strong buffering systems. The standard acidity parameter, the Base Neutralization Capacity (BNC), is determined by endpoint titration, and reflects a cumulative parameter of both hydrogen ions and all buffering systems, but does not give information on the individual buffer systems. We demonstrate that a detailed interpretation of titration curves can provide information about the strength of the buffering systems. The buffering systems are of importance for environmental studies and treatment of acidic mining waters. Titrations were carried out by means of an automatic titrator using acidic mining waters from Germany and Canada. The curves were interpreted, compared with each other, to endpoint titration results and to elemental concentrations contained therein. The titration curves were highly reproducible, and contained information about the strength of the buffer systems present. Interpretations are given, and the classification and comparison of acidic mining waters, by the nature and strength of their buffering systems derived from titration curves are discussed. The BNC-values calculated from the curves were more precise than the ones determined by the standard endpoint titration method. Due to the complex buffer mechanisms in acidic mining waters, the calculation of major metal concentrations from the shape of the titration curve resulted in estimates, which should not be confused with precise elemental analysis results. Titration curves provide an inexpensive, valuable and versatile tool, by which to obtain sophisticated information of the acidity in acidic water. The information about the strength of the present buffer systems can help to understand and document the complex nature of acidic mining water buffer systems. Finally, the interpretation of titration curves could help to

  8. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    Science.gov (United States)

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  9. Evaluation of adhesion of reline resins to the thermoplastic denture base resin for non-metal clasp denture.

    Science.gov (United States)

    Kim, Ji Hye; Choe, Han Cheol; Son, Mee Kyoung

    2014-01-01

    This study aimed to evaluate the tensile and transverse bond strength of chairside reline resins (Tokuyama Rebase II, Mild Rebaron LC) to a thermoplastic acrylic resin (Acrytone) used for non metal clasp denture. The results were compared with those of a conventional heat polymerized acrylic resin (Paladent 20) and a thermoplastic polyamide resin (Biotone). The failure sites were examined by scanning electron microscopy to evaluate the mode of failure. As results, the bond strength of reline resins to a thermoplastic acrylic resin was similar to the value of a conventional heat polymerized acrylic resin. However, thermoplastic polyamide resin showed the lowest value. The results of this study indicated that a thermoplastic acrylic resin for non metal clasps denture allows chairside reline and repair. It was also found that the light-polymerized reline resin had better bond strength than the autopolymerizing reline resin in relining for a conventional heat polymerized acrylic resin and a thermoplastic acrylic resin.

  10. Ultrasonic and densimetric titration applied for acid-base reactions.

    Science.gov (United States)

    Burakowski, Andrzej; Gliński, Jacek

    2014-01-01

    Classical acoustic acid-base titration was monitored using sound speed and density measurements. Plots of these parameters, as well as of the adiabatic compressibility coefficient calculated from them, exhibit changes with the volume of added titrant. Compressibility changes can be explained and quantitatively predicted theoretically in terms of Pasynski theory of non-compressible hydrates combined with that of the additivity of the hydration numbers with the amount and type of ions and molecules present in solution. It also seems that this development could be applied in chemical engineering for monitoring the course of chemical processes, since the applied experimental methods can be carried out almost independently on the medium under test (harmful, aggressive, etc.).

  11. Biophysical characterization of antibodies with isothermal titration calorimetry

    Directory of Open Access Journals (Sweden)

    Verna Frasca

    2016-07-01

    Full Text Available Antibodies play a key role in the immune response. Since antibodies bind antigens with high specificity and tight affinity, antibodies are an important reagent in experimental biology, assay development, biomedical research and diagnostics. Monoclonal antibodies are therapeutic drugs and used for vaccine development. Antibody engineering, biophysical characterization, and structural data have provided a deeper understanding of how antibodies function, and how to make better drugs. Isothermal titration calorimetry (ITC is a label-free binding assay, which measures affinity, stoichiometry, and binding thermodynamics for biomolecular interactions. When thermodynamic data are used together with structural and kinetic data from other assays, a complete structure-activity-thermodynamics profile can be constructed. This review article describes ITC, and discusses several applications on how data from ITC provides insights into how antibodies function, guide antibody engineering, and aid design of new therapeutic drugs.

  12. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  13. Oxygen titration strategies in chronic neonatal lung disease.

    Science.gov (United States)

    Primhak, Robert

    2010-09-01

    The history of oxygen therapy in neonatology has been littered with error. Controversies remain in a number of areas of oxygen therapy, including targets and strategies in supplemental oxygen therapy in Chronic Neonatal Lung Disease (CNLD). This article reviews some of these controversies, and makes some recommendations based on the available evidence. In graduates of neonatal units who are left with CNLD, oxygen saturation should be kept above 93-95%, with levels below 90% being avoided as far as possible. Titration of oxygen should be done using oximetry recordings which include periods of different activities. Weaning of oxygen supplementation should only be done based on satisfactory recordings during a trial of a lower flow. There is insufficient evidence to say whether weaning for increasing hours a day or stepwise weaning to a continuous lower flow is a better method. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. Sailing on the "C": A Vitamin Titration with a Twist

    Science.gov (United States)

    Sowa, S.; Kondo, A. E.

    2003-05-01

    The experiment takes the traditional redox titration of vitamin C using iodine with starch as an indicator, and presents it to the student as a challenge in guided-inquiry format. Two versions, with different levels of difficulty, are provided, to accommodate students with varying levels of problem-solving skills. The "challenge" is both quantitative and qualitative: if you were an eighteenth-century sea captain packing for a voyage to the New World, would you take oranges, lemons, limes, or grapefruits to prevent your crew from getting scurvy? The challenge ties in history, nutrition, and health with chemistry, and provides students an opportunity to work with familiar food products in the laboratory.

  15. Modelling Dynamic Topologies via Extensions of VDM-RT

    DEFF Research Database (Denmark)

    Nielsen, Claus Ballegård

    Only a few formal methods include descriptions of the network topology that the modelled system is deployed onto. In VDM Real-Time (VDM-RT) this has been enabled for distributed systems that have a static structure. However, when modelling dynamic systems this fixed topology becomes an issue....... Systems with highly distributed and alternating relationships cannot be expressed correctly in a static model. This document describes how VDM-RT can be extended with new language constructs to enable the description of dynamic reconfiguration of the network topology during the runtime execution...... of a model. The extension is developed on the basis of a case study involving a dynamic system that has a constant changing system topology. With a basis in the case study a model is developed that uses the static version of VDM-RT in order to reveal the limitations of the language. The case study...

  16. Screening inhibitory potential of anti-HIV RT RNA aptamers.

    Science.gov (United States)

    Lange, Margaret J; Burke, Donald H

    2014-01-01

    Aptamers targeted to HIV reverse transcriptase (RT) have been demonstrated to inhibit RT in biochemical assays and as in cell culture. However, methods employed to date to evaluate viral suppression utilize time-consuming serial passage of infectious HIV in aptamer-expressing stable cell lines. We have established a rapid, transfection-based assay system to effectively examine the inhibitory potential of anti-HIV RT aptamers expressed between two catalytically inactive hammerhead ribozymes. Our system can be altered and optimized for a variety of cloning schemes, and addition of sequences of interest to the cassette is simple and straightforward. When paired with methods to analyze aptamer RNA accumulation and localization in cells and as packaging into pseudotyped virions, the method has a very high level of success in predicting good inhibitors.

  17. Resin selection criteria for tough composite structures

    Science.gov (United States)

    Chamis, C. C.; Smith, G. T.

    1983-01-01

    Resin selection criteria are derived using a structured methodology consisting of an upward integrated mechanistic theory and its inverse (top-down structured theory). These criteria are expressed in a "criteria selection space" which are used to identify resin bulk properties for improved composite "toughness". The resin selection criteria correlate with a variety of experimental data including laminate strength, elevated temperature effects and impact resistance.

  18. Solidifying power station resins and sludges

    International Nuclear Information System (INIS)

    Willis, A.S.D.; Haigh, C.P.

    1984-01-01

    Radioactive ion exchange resins and sludges arise at nuclear power stations from various operations associated with effluent treatment and liquid waste management. As the result of an intensive development programme, the Central Electricity Generating Board (CEGB) has designed a process to convert power station resins and sludges into a shielded, packaged solid monolithic form suitable for final disposal. Research and development, the generic CEGB sludge/resin conditioning plant and the CEGB Active Waste Project are described. (U.K.)

  19. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  20. Porous Ceramic Spheres from Ion Exchange Resin

    Science.gov (United States)

    Dynys, Fred

    2005-01-01

    A commercial cation ion exchange resin, cross-linked polystyrene, has been successfully used as a template to fabricate 20 to 50 micron porous ceramic spheres. Ion exchange resins have dual template capabilities. Pore architecture of the ceramic spheres can be altered by changing the template pattern. Templating can be achieved by utilizing the internal porous structure or the external surface of the resin beads. Synthesis methods and chemical/physical characteristics of the ceramic spheres will be reported.

  1. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    OpenAIRE

    Furuse, Adilson Yoshio; Cunha, Leonardo Fernandes da; Benetti, Ana Raquel; Mondelli, José

    2007-01-01

    The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1) rinsing with water and drying; (G2) application of an adhesive system; (G3) rinsing and drying, abrasion wit...

  2. Soft-Rt: software for IMRT simulations based on MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira F, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Campos, T., E-mail: tcff01@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Programa de Pos Graduacao em Ciencias e Tecnicas Nucleares, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  3. Soft-Rt: software for IMRT simulations based on MCNPX

    International Nuclear Information System (INIS)

    Ferreira F, T. C.; Campos, T.

    2015-10-01

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  4. The ion-sensitive field effect transistor in rapid acid-base titrations

    NARCIS (Netherlands)

    Bos, M.; Bergveld, Piet; van Veen-Blaauw, A.M.W.

    1979-01-01

    Ion-sensitive field effect transistors (ISFETs) are used as the pH sensor in rapid acid—base titrations. Titration speeds at least five times greater than those with glass electrodes are possible for accuracies better than ±1%.

  5. Quick titration of pergolide in cotreatment with domperidone is safe and effective

    NARCIS (Netherlands)

    Jansen, PAF; Herings, RMC; Samson, MM; Schuurmans-Daemen, LMPJ; Hovestadt, A; Verhaar, HJJ; Van Laar, T; de Vreede, P.

    2001-01-01

    The purpose of the study was to analyze efficacy and safety of quick pergolide titration combined with domperidone. In an open-label prospective study, pergolide was titrated in 16 days to a maximum of 3 mg/d doses as adjunctive treatment to L-Dopa in 10 elderly patients with Parkinson's disease.

  6. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  7. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    Science.gov (United States)

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P titration level (P titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  8. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    Science.gov (United States)

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  9. flower extract as an improvised indicator in acid – base titration

    African Journals Online (AJOL)

    USER

    laboratory practical with an instructional material that is useful, economical, simple and accurate for the said titration. Therefore, it is recommended for integrated science and chemistry instructions. Keywords: Flower, acid, base, indicator, titration. INTRODUCTION. In Nigeria, factors militating against science education.

  10. Rapid and simple determination of oxyphenbutazone in dosage forms by biamperometric titration.

    Science.gov (United States)

    Sebková, D; Safarík, L

    1986-01-01

    Oxyphenbutazone was determined in the presence of glacial acetic acid, hydrochloric acid, and potassium bromide by bromometric titration with biamperometric end point indication. The course of the titration was followed with double platinum electrode with 100 mV of polarizing voltage.

  11. Novel silica-based ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    Eichrom`s highly successful Diphonixo resin resembles a conventional ion exchange resin in its use of sulfonic acid ligands on a styrene- divinylbenzene matrix. Diphonix resin exhibits rapid exchange kinetics that allow economical operation of ion exchange systems. Unlike conventional resins, Diphonix resin contains chelating ligands that are diphosphonic acid groups that recognize and remove the targeted metals and reject the more common elements such as sodium, calcium and magnesium. This latter property makes Diphonix ideal for many industrial scale applications, including those involving waste treatment. For treatment of low-level, transuranic (TRU) and high- level radioactive wastes, Diphonix`s polystyrene backbone hinders its application due to radiolytic stability of the carbon-hydrogen bonds and lack of compatibility with expected vitrification schemes. Polystyrene-based Diphonix is approximately 60% carbon- hydrogen. In response to an identified need within the Department of Energy for a resin with the positive attributes of Diphonix that also exhibits greater radiolytic stability and final waste form compatibility, Eichrom has successfully developed a new, silica-based resin version of Diphonix. Target application for this new resin is for use in environmental restoration and waste management situations involving the processing of low-level, transuranic and high-level radioactive wastes. The resin can also be used for processing liquid mixed waste (waste that contains low level radioactivity and hazardous constituents) including mixed wastes contaminated with organic compounds. Silica-based Diphonix is only 10% carbon-hydrogen, with the bulk of the matrix silica.

  12. Microbiological study of water-softener resins.

    Science.gov (United States)

    Stamm, J M; Engelhard, W E; Parsons, J E

    1969-09-01

    Microbial identification using effluents backflushed from exhausted urban and rural tank resins and cleaned resins containing the sulfonated copolymer of styrene and divinylbenzene (SDB) were completed, along with microbial assessment of the concentrated stock salt brine. Forty-four different bacterial and fungal genera were identified. Extensive biochemical and animal virulence tests completed on one of the six bacterial salt brine isolates indicated a pathogenic staphylococcal strain. The retention of Staphylococcus aureus, a Flavobacterium sp, and Escherichia coli B bacteriophage was demonstrated both by using the nonexhausted sodium-regenerated resin and by using the same resin exchanged with different mono-, di-, and trivalent cations. Effluent counts completed after bacterial seepage through the resins indicated the Pb(++) exchanged resin removed 55% of the bacteria; Na(+), Fe(++), and Al(+++) removed 31 to 36% and Ca(++) and Cu(++) removed about 10 to 15%. Seventy per cent or more of the bacteriophage was removed by Fe(++), Cu(++), and Al(+++), whereas the Ca(++) and Na(++) cations removed 25 to 31%. Over a 77-day period, nonsterile tap water was passed through bacterial seeded and uninoculated SDB (Na) resin columns. Effluent and resin elution counts demonstrated the growth and survival of 2 different bacteria per column. Increased bacterial retention, survival, and multiplication occurred concomitantly with accumulation of organic and inorganic materials and the Ca(++) and Mg(++) cations from the tap water. Furthermore, microbial elution from resin particles taken from column depths of 1, 8, and 16 cm indicated a bacterial diminution with increasing depths.

  13. RT-PCR detection of HIV in Republic of Macedonia.

    Science.gov (United States)

    Bosevska, Golubinka; Panovski, Nikola; Dokić, Eleni; Grunevska, Violeta

    2008-11-01

    The aim of the study was to detect HIV RNA in seropositive patients using RT-PCR method and thus, to establish PCR methodology in the routine laboratory works. The total of 33 examined persons were divided in two groups: 1) 13 persons seropositive for HIV; and 2) 20 healthy persons - randomly selected blood donors that made the case control group. The subjects age was between 25 and 52 years (average 38,5). ELFA test for combined detection of HIV p24 antigen and anti HIV-1+2 IgG and ELISA test for detection of antibodies against HIV-1 and HIV-2, were performed for each examined person. RNA from the whole blood was extracted using a commercial kit based on salt precipitation. Detection of HIV RNA was performed using RT-PCR kit. Following nested PCR, the product was separated by electrophoresis in 1,5 % agarose gel. The result was scored positive if the band of 210bp was visible regardless of intensity. Measures of precaution were taken during all the steps of the work and HIV infected materials were disposed of accordingly. In the group of blood donors ELFA, ELISA and RT-PCR were negative. Assuming that prevalence of HIV infection is zero, the clinical specificity of RT-PCR is 100 %. The analytical specificity of RT-PCR method was tested against Hepatitis C and B, Human Papiloma Virus, Cytomegalovirus, Herpes Simplex Virus, Rubella Virus, Mycobacterium tuberculosis, Chlamydia trachomatis. None of these templates yielded amplicon. In the group of 13 seropositive persons, 33 samples were analyzed. HIV RNA was detected in 15 samples. ELISA and ELFA test were positive in all samples. Different aliquots of the samples were tested independently and showed the same results. After different periods of storing the RNA samples at -70 masculineC, RT-PCR reaction was identical to the one performed initially. The obtained amplicons were maintained frozen at -20 masculineC for a week and the subsequently performed electrophoresis was identical to the previous one. The reaction is

  14. RT-PCR Detection of HIV in Republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Golubinka Bosevska

    2008-11-01

    Full Text Available The aim of the study was to detect HIV RNA in seropositive patients using RT-PCR method and thus, to establish PCR methodology in the routine laboratory works.The total of 33 examined persons were divided in two groups: 1 13 persons seropositive for HIV; and 2 20 healthy persons - randomly selected blood donors that made the case control group. The subjects age was between 25 and 52 years (average 38,5.ELFA test for combined detection of HIV p24 antigen and anti HIV-1 + 2 IgG and ELISA test for detection of antibodies against HIV-1 and HIV-2, were performed for each examined person. RNA from the whole blood was extracted using a commercial kit based on salt precipitation. Detection of HIV RNA was performed using RT-PCR kit. Following nested PCR, the product was separated by electrophoresis in 1,5 % agarose gel. The result was scored positive if the band of 210bp was visible regardless of intensity Measures of precaution were taken during all the steps of the work and HIV infected materials were disposed of accordingly.In the group of blood donors ELFA, ELISA and RT-PCR were negative. Assuming that prevalence of HIV infection is zero, the clinical specificity of RT-PCR is 100 %. The analytical specificity of RT-PCR method was tested against Hepatitis C and B, Human Papiloma Virus, Cytomegalovirus, Herpes Simplex Virus, Rubella Virus, Mycobacterium tuberculosis, Chlamydia trachomatis. None of these templates yielded amplicon. In the group of 13 seropositive persons, 33 samples were analyzed. HIV RNA was detected in 15 samples. ELISA and ELFA test were positive in all samples. Different aliquots of the samples were tested independently and showed the same results. After different periods of storing the RNA samples at -70°C, RT-PCR reaction was identical to the one performed initially. The obtained amplicons were maintained frozen at -20°C for a week and the subsequently performed electrophoresis was identical to the previous one. The reaction is

  15. Heat-cured Acrylic Resin versus Light-activated Resin: A Patient ...

    African Journals Online (AJOL)

    Context: Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed ...

  16. Selectivity evaluation and separation of human immunoglobulin G, Fab and Fc fragments with mixed-mode resins.

    Science.gov (United States)

    Luo, Ying-Di; Zhang, Qi-Lei; Yuan, Xiao-Ming; Shi, Wei; Yao, Shan-Jing; Lin, Dong-Qiang

    2017-01-01

    Adsorption selectivity is critical important for mixed-mode chromatography with specially-designed ligands. Human immunoglobulin G (hIgG), Fc and Fab fragments were used in the present work to evaluate adsorption behavior and binding selectivity of four mixed-mode resins with the ligands of 4-mercatoethyl-pyridine (MEP), 2-mercapto-1-methylimidazole (MMI), 5-aminobenzimidazole (ABI) and tryptophan-5-aminobenzimidazole (W-ABI), respectively. The resins showed an obvious pH-dependent adsorption behavior. High adsorption capacities were found at neutral pH for hIgG, Fc and Fab, and almost no adsorption happened under acidic conditions. An adsorption selectivity index was proposed to evaluate separation efficiency. High specificity of hIgG/Fc was found at pH 8.9 for MEP resin, and for W-ABI resin at pH 8.0 and 8.9. In addition, isothermal titration calorimetry was used to evaluate ligand-protein interactions. Finally, the separation of hIgG and Fc (1:1) was optimized with mixed-mode resins, and the best separation performance was obtained with W-ABI-based resin. Loading at pH 8.0 resulted in the flow through of Fc with purity of 90.4% and recovery of 98.8%, while elution at pH 3.6 provided hIgG with purity of 99.7% and recovery of 86.5%. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  18. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  19. Molybdenum (6) determination by the method of high-frequency and pH titration

    International Nuclear Information System (INIS)

    Lukianets, I.G.; Kulish, N.G.

    1981-01-01

    A possibility to determine Mo(6) using the method of high frequency and pH-metric titration is investigated. By means of the high frequency contact R-cell Mo(6) titration is performed using different precipitators: 8-oxiquinoline, lead nitrate and acetate and silver nitrate. It is established that the best conditions are achieved during titration of 67.2-1343 mg/10 ml Mo(6) with lead acetate (pH 4.5-6.5). Relative standard deviation Ssub(r) constitutes 0.005 pH-metric titration of Mo(6) with complexone 3 is studied. The range of Mo(6) concentrations determined constitutes 13.43-134.3 mg at pH initial value of 3.5-5.5. Relative standard deviation Ssub(r) constitutes 0.003. Techniques of molybdenum determination in ferromolybdenum using the method of high frequency and pH-metric titration are developed [ru

  20. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    Science.gov (United States)

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  1. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Directory of Open Access Journals (Sweden)

    Eva Tavčar

    2012-01-01

    Full Text Available The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD=4.3%, accuracy, and linearity (2=0.997.

  2. Simple modification of karl-Fischer titration method for determination of water content in colored samples.

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R(2) = 0.997).

  3. Comparison of Cashew Nut Shell Liquid (CNS ) Resin with ...

    African Journals Online (AJOL)

    synthetic) resin. Compressive and tensile strength tests conducted proved that composites developed with cashew nut shell liquid (CNSL) resin were comparable to those developed with polyester resin. In the results, CNSL has an ultimate ...

  4. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-III Presentation of a fully automatic titration apparatus and of results supporting the theories given in the preceding parts.

    Science.gov (United States)

    Pehrsson, L; Ingman, F

    1977-02-01

    This paper forms Part III of a series in which the first two parts describe methods for evaluating titrations performed by stepwise addition of equal volumes of titrant. The great advantage of these methods is that they do not require an accurate calibration of the electrode system. This property makes the methods very suitable for routine work. e.g., in automatic analysis. An apparatus for performing such titrations automatically is presented. Further, results of titrations of monoprotic acids, a diprotic acid, an ampholyte, a mixture of an acid with its conjugate base, and mixtures of two acids with a small difference between the stability constants are given. Most of these titrations cannot be evaluated by the Gran or Hofstee methods but yield results having errors of the order of 0.1% if the methods proposed in Parts I and II of this series are employed. The advantages of the method of stepwise addition of equal volumes of titrant combined with the proposed evaluation methods, in comparison with common methods such as titration to a preset pH, are that all the data are used in the evaluation, permitting a statistical treatment and giving better possibilities for tracing systematic errors.

  5. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    Science.gov (United States)

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  6. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    Science.gov (United States)

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  7. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    Science.gov (United States)

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  8. Potentiometric titrations of molybdenum and vanadium in aqueous and mixed so lvents

    International Nuclear Information System (INIS)

    Das, S.K.; Dhaneshwar, R.G.

    1990-01-01

    Potentiometric titration method was developed for molybdenum, employing different electrode systems. Molybdenum(VI) is reduced to molybdenum(V) by ferrous solution in presence of phosphoric acid and then titrated with potassium dichromate. It was found that ferrous concentration should be five times more than molybdenum and phosphoric acid should be 1.0 ml for 0.1N titration and 0.5 ml for lower concentration titrations. The method is also applicable to vanadium titrations. Employing Au/SCE and Pt/SCE systems, it was observed that generally curve heights obtained for platinum electrode are higher than those for gold electrode. Also for both the electrode systems, the curve heights for vanadium titrations were found to be more than those for molybdenum. Lower limits of titrations for Au/SCE system are 0.01N for molybdenum and 0.0001N for vanadium, whereas for Pt/SCE system, the lower limits obtained were 0.01N for both molybdenum and vanadium titrations. In order to improve the sensitivities of the method, the bimetallic electrode systems Au/Pt and Pt/Au were employed. Au/Pt system was found to give better results than Pt/Au systems. Addition of organic solvent was found to have beneficial effects for titrations of 0.001N and below. Methanol was found to be a better solvent than ethanol. Molybdenum titrations, at 0.0001N level could be performed in methanol with Au/Pt system, which is to b e generally preferred than Pt/Au system. (author). 7 refs., 3 tabs

  9. Macromolecular competition titration method accessing thermodynamics of the unmodified macromolecule-ligand interactions through spectroscopic titrations of fluorescent analogs.

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand-macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein-nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein-nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein-nucleic acid interactions, it can generally be applied to any ligand-macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Macromolecular Competition Titration Method: Accessing Thermodynamics of the Unmodified Macromolecule–Ligand Interactions Through Spectroscopic Titrations of Fluorescent Analogs

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand–macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein–nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein–nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein–nucleic acid interactions, it can generally be applied to any ligand–macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. PMID:21195223

  11. Resin composite for sealing and its use in a solar cell. Fushiyo jushi soseibutsu oyobi sore wo mochiita taiyo denchi

    Energy Technology Data Exchange (ETDEWEB)

    Toma, H.; Mimura, T.; Takehara, N.

    1994-01-28

    This invention presents resin composites for sealing of a solar cell composed of a hardening resin and a thermoplastic resin which has a number average molecular weight larger than that of the hardening resin and is soluble in the hardening resin, and the invention affords a solar cell to endure a long-term stable operation and to give a good performance. The hardening resin includes unsaturated polyester resin, phenolic resin, alkyd resin, unsaturated acrylic resin, epoxy resin, polyurethane resin, melamine resin, diallyl phthalate resin, their oligomers and their modifications. The thermoplastic resin includes saturated polyester resin, phenolic resin, acrylic resin, styrene resin, epoxy resin, polyurethane resin, polyvinyl acetate resin, polyvinyl chloride resin, polyvinyl alcohol resin, polyacetal resin, their modifications and their copolymer resin. 2 figs., 3 tabs.

  12. Curing kinetics of alkyd/melamine resin mixtures

    OpenAIRE

    Jovičić Mirjana C.; Radičević Radmila Ž.

    2009-01-01

    Alkyd resins are the most popular and useful synthetic resins applied as the binder in protective coatings. Frequently they are not used alone but are modified with other synthetic resins in the manufacture of the coatings. An alkyd/melamine resin mixture is the usual composition for the preparation of coating called 'baking enamel' and it is cured through functional groups of resins at high temperatures. In this paper, curing kinetics of alkyd resins based on castor oil and dehydrated castor...

  13. Narr kui ajastu metafoor / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    2001-01-01

    William Shakespeare'i "Kuningas Lear" (lav. Priit Pedajas) ja Pedro Calder̤n de la Barca "Elu on unenägu" (lav. Ingo Normet) Eesti Draamateatris. Ilmunud ka kogumikus : Hellerma, Kärt. Avanenud ruum. Tallinn : Eesti Keele Sihtasutus, 2006, lk. 213-216. Pealk. Narr kui meie aja kangelane

  14. Systemisk vaskulært lækage-syndrom

    DEFF Research Database (Denmark)

    Kjærgaard, Krista Dybtved; Rickers, Hans

    2008-01-01

    , træthed og ødemer) og biokemiske abnormiteter (hypoalbuminæmi, hæmokoncentration og monoklonalkomponent), som viste, at tilstanden var forenelig med den akutte - og potentielt letale - form af systemisk vaskulært lækage-syndrom. Ved Mayo Clinic i USA har man haft gode resultater med profylaktisk...

  15. Kirjanduskriitikute suvemängud / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    2007-01-01

    Arvustus: Lodge, David. Ühest kohast teise / tlk. Aet Varik. Tallinn : Varrak, 2005 ; Lodge, David. Väike maailm / tlk. Kersti Unt. Tallinn : Varrak, 1996 ; Lodge, David. Väärt töö / tlk. Kersti Unt. Tallinn : Varrak, 2006

  16. Torm Balti merel / Märt Treier ; interv. Inge Pitsner

    Index Scriptorium Estoniae

    Treier, Märt, 1975-

    2004-01-01

    TV3 näitab saksa poliitilist põnevusfilmi "Balti torm" ("Baltic Storm"), mis kujutab parvlaev "Estonia" hukku : stsenarist, produtsent Jutta Rabe : režissöör Reuben Leder. Filmi eel on teles Märt Treieri saade "Tormist sündinud tormid"

  17. Use of rt-PA (Alteplase) for acute cerebral infarction

    International Nuclear Information System (INIS)

    Oshibuchi, Rumi; Fukusako, Toshihiro; Matayoshi, Yasutoshi; Shiramoto, Kiyotaka; Itoh, Makoto; Oka, Hideo

    2008-01-01

    Among those patients with cerebral infarction who were brought to our emergency department from December 2005 through June 2007, 28 satisfied the criteria for indication for alteplase, recombinant tissue plasminogen activator (rt-PA), and served as the subjects of this study. According to the treatment protocol that our group, led by neurologists, had prepared, 0.6 mg/kg of rt-PA was administered following a CT of the head region that negated the presence of a brain hemorrhage. The time that elapsed between onset and rt-PA administration was 41-167 minutes (median 95). For 24 hours after medication, the patients were placed under respiratory and circulatory care and their neurological performances were observed in an intensive care unit (ICU) or a neurological ward. On a modified ranking scale, which indicates the possibility for social rehabilitation, 9 patients (32%) were rated to be between 0 to 1. Four (14%) succumbed during this period. By formulating a treatment protocol, rapid administration of rt-PA and monitoring to prevent complications became possible. (author)

  18. rt, Arvo: De profundis. Missa Sillabica / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1997-01-01

    Uuest heliplaadist "Pärt, Arvo: De profundis. Missa Sillabica. Solfeggio. And one of the Pharisees. Cantate Domino. Summa. 7 Antiennes du Magnificat. The Beautitudes. Magnificat. Christopher Bowers-Broadbent (org.), Daniel Kennedy (perc.). Theatre of Voices / Paul Hillier (bass)" Harmonia Mundi HMU907 182 F (CD:165F). 1996. TT:1h 16'06"

  19. Future of the reprocessing business at the RT-1 plant

    International Nuclear Information System (INIS)

    Bukharin, O.

    1995-01-01

    Economic viability of reprocessing operations at the RT-1 plant is provided by the contracts with nuclear utilities from Finland and Hungary. Finland will stop sending fuel to Mayak for reprocessing after 1996. Hungary will be capable to resolve the problem of spent fuel domestically some time in the future. This increases vulnerability of the reprocessing business at Mayak to future political uncertainties. (author)

  20. RT-PCR Protocols - Methods in Molecular Biology

    Directory of Open Access Journals (Sweden)

    Manuela Monti

    2011-03-01

    Full Text Available “The first record I have of it, is when I made a computer file which I usually did whenever I had an idea, that would have been on the Monday when I got back, and I called it Chain Reaction.POL, meaning polymerase. That was the identifier for it and later I called the thing the Polymerase Chain Reaction, which a lot of people thought was a dumb name for it, but it stuck, and it became PCR”. With these words the Nobel prize winner, Kary Mullis, explains how he named the PCR: one of the most important techniques ever invented and currently used in molecular biology. This book “RT-PCR Protocols” covers a wide range of aspects important for the setting of a PCR experiment for both beginners and advanced users. In my opinion the book is very well structured in three different sections. The first one describes the different technologies now available, like competitive RT-PCR, nested RT-PCR or RT-PCR for cloning. An important part regards the usage of PCR in single cell mouse embryos, stressing how important...........

  1. 25 kaadrit sekundis / Liis Auväärt

    Index Scriptorium Estoniae

    Auväärt, Liis

    2009-01-01

    Nukufilmis käib töö filmiga "Lisa Limone & Maroc Orange", režissöör Mait Laas, animaatorid Triin Sarapik-Kivi, Märt Kivi, operaator Ragnar Neljandi, nukumeistrid Heigo Eeriksoo, Taivo Müürsep, Ene Mellow ja Kreeta Käeri. Dekoratsioonimeistrid Mait Erik ja Roman Kuznetsov

  2. Karje kunstniku südamest / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    1997-01-01

    Arvustus: Dinesen, Isak [Blixen, Karen]. Babette'i pidusöök / tlk. Piret Peiker. Tallinn : Varrak, 1996. Ilmunud ka kogumikus: Hellerma, Kärt. Kohanenud kirjandus : valik kirjanduskriitikat 1987-2006. Eesti Keele Sihtasutus : Tallinn, 2006. Lk. 167-169

  3. rt: Chamber and Orchestral Works / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1994-01-01

    Uuest heliplaadist "Pärt: Chamber and Orchestral Works. Bournemouth Sinfonietta, Richard Studt. EMI Eminence CD CD-EMX 2221; Fratres; Cantus in memory of Benjamin Britten; Summa; Spiegel im Spiegel; Festina lente; Tabula Rasa; Fratres - selected comparison: Bachmann, Kibonoff (12/94)(CATA) 09026 61824-2. Kremer, Jarrett (ECM) 817 764-2

  4. Input to Resin Column Structural Analysis if Autocatalytic Resin Reaction Occurs in HB-Line Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Hallman, D.F.

    2001-07-10

    Solutions of plutonium in nitric acid are purified and concentrated using anion resin prior to precipitation. There have been instances of resin column explosions caused by autocatalytic reactions of anion resins in nitric acid within the DOE complex

  5. Gold Loading on Ion Exchange Resins in Non-Ammoniacal Resin-Solution Systems

    Directory of Open Access Journals (Sweden)

    Abrar Muslim

    2010-12-01

    Full Text Available The loading of gold using strong base anion exchange resin in non-ammoniac resin-solution (NARS systems has been studied. The loading of gold onto ion exchange resins is affected by polythionate concentration, and trithionate can be used as the baseline in the system. The results also show that resin capacity on gold loading increases due to the increase in the equilibrium thiosulfate concentration in the NARS system. Gold loading performances show the need of optimization the equilibrium concentrations of thiosulfate in the NARS system. Keywords: equilibrium, gold loading, resin capacity, thiosulfate, trithionate

  6. Polyimide Resins Resist Extreme Temperatures

    Science.gov (United States)

    2009-01-01

    Spacecraft and aerospace engines share a common threat: high temperature. The temperatures experienced during atmospheric reentry can reach over 2,000 F, and the temperatures in rocket engines can reach well over 5,000 F. To combat the high temperatures in aerospace applications, Dr. Ruth Pater of Langley Research Center developed RP-46, a polyimide resin capable of withstanding the most brutal temperatures. The composite material can push the service temperature to the limits of organic materials. Designed as an environmentally friendly alternative to other high-temperature resins, the RP-46 polyimide resin system was awarded a 1992 "R&D 100" award, named a "2001 NASA Technology of the Year," and later, due to its success as a spinoff technology, "2004 NASA Commercial Invention of the Year." The technology s commercial success also led to its winning the Langley s "Paul F. Holloway Technology Transfer Award" as well as "Richard T. Whitcom Aerospace Technology Transfer Award" both for 2004. RP-46 is relatively inexpensive and it can be readily processed for use as an adhesive, composite, resin molding, coating, foam, or film. Its composite materials can be used in temperatures ranging from minus 150 F to 2,300 F. No other organic materials are known to be capable of such wide range and extreme high-temperature applications. In addition to answering the call for environmentally conscious high-temperature materials, RP-46 provides a slew of additional advantages: It is extremely lightweight (less than half the weight of aluminum), chemical and moisture resistant, strong, and flexible. Pater also developed a similar technology, RP-50, using many of the same methods she used with RP-46, and very similar in composition to RP-46 in terms of its thermal capacity and chemical construction, but it has different applications, as this material is a coating as opposed to a buildable composite. A NASA license for use of this material outside of the Space Agency as well as

  7. The solidification of spent resin

    International Nuclear Information System (INIS)

    Shiao, S. J.; Tsai, C. M.; Shyu, Y. H.

    1991-01-01

    A quasi-steady apparatus was applied to measure the thermal conductivity of solids ranging in size for 0.3 to 200 L, and temperature distributions in the solids were recorded during the curing, and theoretical equation for conduction in a cylindrical form with uniform energy generation was established to define the thermal state of reaction. The heat of reaction calculated from the theoretical equation with experimental values for the maximum temperature and thermal conductivity agrees very well with the data reported. The relationships among heat of reaction and amount of curing agent, retardant, loading of spent resin, and water were established

  8. Comparison of Cashew Nut Shell Liquid (CNS Resin with Polyester Resin in Composite Development

    Directory of Open Access Journals (Sweden)

    C. C. Ugoamadi

    2013-12-01

    Full Text Available Natural resins can compete effectively with the synthetic ones in composite development. In this research, cashew nuts were picked and processed for the extraction of the resin content. The resin (natural resin so obtained was mixed with cobalt amine (accelerator, methyl ethyl ketone peroxide (catalyst to develop two sets of composite specimens – specimens without fibres and specimens reinforced with glass fibres. This method of sample specimen development was repeated with polyester (synthetic resin. Compressive and tensile strength tests conducted proved that composites developed with cashew nut shell liquid (CNSL resin were comparable to those developed with polyester resin. In the results, CNSL has an ultimate compressive strength of 55MPa compared to that of polyester resin with an ultimate strength of 68MPa. The result of tensile strength proved cashew nut shell liquid resin (with ultimate strength of 44MPa to be better than polyester resin with 39MPa as ultimate tensile strength. This means that natural resins could be a better substitute for the synthetic ones when the required quantities of fibers (reinforcements and fillers are used in the fibre-reinforced plastic composite developments.

  9. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments.

    Science.gov (United States)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel; Mondelli, José

    2007-12-01

    The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1) rinsing with water and drying; (G2) application of an adhesive system; (G3) rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4) rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (presin increments.

  10. resin as polymer-supported synthesis support

    Indian Academy of Sciences (India)

    Administrator

    dichloro-5,6-dicyano- benzoqunone ... ports used most widely in SPOS are Merrifield resin .... (2 × 10 mL). The resin was dried at 50°C for one hour to give white beads. IR (KBr): 3108, 3312 cm–1. 1H-NMR (500 MHz, CDCl3): δ 7⋅13 (br s, PS), 7⋅01.

  11. [Delayed asthma bronchiale due to epoxy resin].

    Science.gov (United States)

    Authried, Georg; Al-Asadi, Haifaa; Møller, Ulla; Sherson, David Lee

    2013-10-28

    Epoxy resin is a low molecular weight agent, which can cause both acute and delayed allergic reactions. However, it is known causing skin reactions with direct or airborne contact. Rarely it can cause airway reactions like asthma bronchiale. We describe a case of a windmill worker who developed delayed asthma bronchiale due to airborne contact with epoxy resin.

  12. Epoxidation of linseed oil-Alkyd resins

    International Nuclear Information System (INIS)

    Motawie, A.M.; Ismail, E.A.; Mazroua, A.M.; Abd EI Aziem, M.S.; Ramadan, A.M.

    2004-01-01

    Three types of different linseed oil-alkyd resin ( Alk (I), Alk (II), and Alk (III) ) were prepared with the calculated amounts of mono glycerides and adipic acid (1:1, 1:2, and 2:1 Eq.Wt) respectively via monoglyceride method. The obtained alkyd resins were epoxidized via reaction with the calculated quantities of peracetic acid, which was prepared by the reaction of acetic anhydride with H 2 O 2 . Epoxidation occurred with the ratio (1: 1, 1 :3, and 1:6 Eq. Wt) of alkyd to peracetic acid. The effect of reaction time on the epoxy group content was measured during the epoxidation process. The prepared alkyd resins were analyzed by IR and H 1 NMR. The metal coated film properties of epoxidized alkyd resins were compared with those of unmodified alkyd resins. It was observed that the coating films of epoxidized alkyd resins have better in drying properties, hardness, adhesion, impact and flexibility than those of un epoxidized alkyd resins. The flammability properties of the paper coated films for the prepared brominated epoxidized alkyd resins were found to be fire retardant

  13. Facile synthesis of hypercrosslinked resins via chloromethylation ...

    Indian Academy of Sciences (India)

    A sort of non-polystyrene type hypercrosslinked resin was firstly synthesized through chloromethylation of simple aryl molecules (benzene, toluene, naphthalene, diphenyl), succedent continuous Friedel–Crafts alkylation polymerization and post-crosslinking reaction. The chemical and porous structures of these novel resins ...

  14. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-II Theory of titration of mixtures of acids, polyprotic acids, acids in mixture with weak bases, and ampholytes.

    Science.gov (United States)

    Pehrsson, L; Ingman, F; Johansson, S

    A general method for evaluating titration data for mixtures of acids and for acids in mixture with weak bases is presented. Procedures are given that do not require absolute [H]-data, i.e., relative [H]-data may be used. In most cases a very rough calibration of the electrode system is enough. Further, for simple systems, very approximate values of the stability constants are sufficient. As examples, the titration of the following are treated in some detail: a mixture of two acids, a diprotic acid, an acid in presence of its conjugate base, and an ampholyte.

  15. Arvo Pärt jagab preemia koolidele / Rebekka Lotman, Eva Kübar ; kommenteerinud Arvo Pärt

    Index Scriptorium Estoniae

    Lotman, Rebekka, 1978-

    2009-01-01

    Kultuuriministeerium tegi ettepaneku anda Arvo Pärdile elutööpreemia, millega kaasneva rahasumma lubas Pärt kinkida Rakvere ja Paide muusikakoolile. Elutööpreemiad saavad veel Ellen Niit ja Aarne Üksküla

  16. rt Haamer: Tsahknal pole Overalliga mingisugust seost / Märt Haamer ; intervjueerinud Jan Jõgis-Laats

    Index Scriptorium Estoniae

    Haamer, Märt, 1973-

    2009-01-01

    Overall Eesti juhi Märt Haameri väitel pole Anders Tsahkna ühtegi riigihanget Overalli ettevõtetele suunanud. Overalli omandusse kuuluv firma Gennet Lab on olnud alltöövõtja paaris E-tervise Sihtasutuse korraldatud hankes

  17. Physical Properties of Synthetic Resin Materials

    Science.gov (United States)

    Fishbein, Meyer

    1939-01-01

    A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

  18. Electrodialytic decontamination of spent ion exchange resins

    International Nuclear Information System (INIS)

    Nott, B.R.

    1982-01-01

    Development of a novel electrodialytic decontamination process for the selective removal of radioactive Cs from spent ion exchange resins containing large amounts of Li is described. The process involves passage of a dc electric current through a bed of the spent ion exchange resin in a specially designed electrodialytic cell. The radiocesium so removed from a volume of the spent resin is concentrated onto a much smaller volume of a Cs selective sorbent to achieve a significant radioactive waste volume reduction. Technical feasibility of the electrodialytic resin decontamination process has been demonstrated on a bench scale with a batch of simulated spent ion exchange resin and using potassium cobalt ferrocyanide as the Cs selective sorbent. A volume reduction factor between 10 and 17 has been estimated. The process appears to be economically attractive. Improvements in process economics can be expected from optimization of the process. Other possible applications of the EDRD process have been identified

  19. Embedding of reactor wastes in plastic resins

    International Nuclear Information System (INIS)

    1979-01-01

    STEAG Kernenergie GmbH is so far the only firm commercially to condition radioactive bead ion exchange resins by embedding in polystyrene resins. The objective of the work reported here was to study and develop methods for immobilization of other reactor wastes in plastic resins. Comparison studies on high quality cement however showed favourable results for cement with respect to process safety and economy. For this reason STEAG interrupted its work in the field of resin embedding after about one year. The work carried out during this period is surveyed in this report, which includes a comprehensive literature study on reactor wastes and their solidification in plastic resins as well as on regulations with regard to radioactive waste disposal in the member states of the European Communities

  20. Disinfection of denture base acrylic resin.

    Science.gov (United States)

    Lin, J J; Cameron, S M; Runyan, D A; Craft, D W

    1999-02-01

    During repair or adjustments of acrylic resin removable complete and partial dentures, particles of the acrylic resin from the interior of the prosthesis may expose dental personnel to microbial health hazards if the prosthesis has not been thoroughly disinfected. This study investigates the efficacy of a commercially prepared microbial disinfectant (Alcide) on the external and internal surfaces of acrylic resins. Four groups of acrylic resin were incubated in an experimental model to simulate the oral environment over time. Specimens were treated in 2 groups, disinfected and not disinfected, and then further grouped by breaking and not breaking. Analysis was performed with microbial colony counts, SEM, and statistical analyses. Viable microorganisms still remain on the internal and external surfaces of treated resins. Chlorine dioxide reduces, but does not eliminate, viable microorganisms on these dental prostheses.

  1. Benefit of slow titration of paroxetine to treat depression in the elderly.

    Science.gov (United States)

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Improvement of Barley yellow dwarf virus-PAV detection in single aphids using a fluorescent real time RT-PCR.

    Science.gov (United States)

    Fabre, Frédéric; Kervarrec, Christine; Mieuzet, Lucie; Riault, Gérard; Vialatte, Aude; Jacquot, Emmanuel

    2003-06-09

    One of the major factors determining the incidence of Barley yellow dwarf virus (BYDV) on autumn-sown cereals is the viruliferous state of immigrant winged aphids. This variable is assessed routinely using the enzyme-linked immunosorbant assay (ELISA). However, the threshold for virus detection by ELISA can lead to false negative results for aphids carrying less than 10(6) particles. Although molecular detection techniques enabling the detection of lower virus quantities in samples are available, the relatively laborious sample preparation and data analysis have restricted their use in routine applications. A gel-free real-time one-step reverse transcription polymerase chain reaction (RT-PCR) protocol is described for specific detection and quantitation of BYDV-PAV, the most widespread BYDV species in Western Europe. This new assay, based on TaqMan technology, detects and quantifies from 10(2) to 10(8) BYDV-PAV RNA copies. This test is 10 and 10(3) times more sensitive than the standard RT-PCR and ELISA assays published previously for BYDV-PAV detection and significantly improves virus detection in single aphids. Extraction of nucleic acids from aphids using either phenol/chloroform or chelatin resin-based protocols allow the use of pooled samples or of a small part (up to 1/1600th) of a single aphid extract for efficient BYDV-PAV detection.

  3. Solidification of ion exchange resin wastes

    International Nuclear Information System (INIS)

    1982-08-01

    Solidification media investigated included portland type I, portland type III and high alumina cements, a proprietary gypsum-based polymer modified cement, and a vinyl ester-styrene thermosetting plastic. Samples formulated with hydraulic cement were analyzed to investigate the effects of resin type, resin loading, waste-to-cement ratio, and water-to-cement ratio. The solidification of cation resin wastes with portland cement was characterized by excessive swelling and cracking of waste forms, both after curing and during immersion testing. Mixed bed resin waste formulations were limited by their cation component. Additives to improve the mechanical properties of portland cement-ion exchange resin waste forms were evaluated. High alumina cement formulations dislayed a resistance to deterioration of mechanical integrity during immersion testing, thus providing a significant advantage over portland cements for the solidification of resin wastes. Properties of cement-ion exchange resin waste forms were examined. An experiment was conducted to study the leachability of 137 Cs, 85 Sr, and 60 Co from resins modified in portland type III and high alumina cements. The cumulative 137 Cs fraction release was at least an order of magnitude greater than that of either 85 Sr or 60 Co. Release rates of 137 Cs in high alumina cement were greater than those in portland III cement by a factor of two.Compressive strength and leach testing were conducted for resin wastes solidified with polymer-modified gypsum based cement. 137 Cs, 85 Sr, and 60 Co fraction releases were about one, two and three orders of magnitude higher, respectively, than in equivalent portland type III cement formulations. As much as 28.6 wt % dry ion exchange resin was successfully solidified using vinyl ester-styrene compared with a maximum of 25 wt % in both portland and gypsum-based cement

  4. Monitoring Acid–Base Titrations on Wax Printed Paper Microzones Using a Smartphone

    Directory of Open Access Journals (Sweden)

    Sandro A. Nogueira

    2017-05-01

    Full Text Available This study describes the use of a smartphone for monitoring acid–base titrations on wax printed paper microzones. An array of twelve microzones of 5 mm diameter each was wax printed on filter paper. The analytical performance of the proposed devices was explored with acid–base titrations examples, where jaboticaba peel extract was used as a natural pH indicator. The color intensity was captured using a smartphone and analyzed through a free App named Photometrix®. Before titrations, color intensity versus pH was calibrated to be used as a reference in titrations as (i strong acid versus strong base; (ii strong base versus strong acid; and (iii weak acid versus strong base. In all examples, images were obtained after the addition of each aliquot of titrant solutions. The obtained titration curves showed the same behavior as the conventional titration curves. After evaluating the feasibility of the proposed methodology, the concentration level of acetic acid was obtained in three vinegar samples. Although the obtained values ranged from 5% to 8% compared to the concentrations on the conventional method, the proposed methodology presented high analytical reliability. The calculated concentrations of acetic acid in three samples ranged from 3.87% to 3.93%, and the proposed methodology did not significantly differ from classic acid–base titration at a confidence level of 95%. The acid–base titration on paper-based devices is outstanding, since any titration can be completed within 5 min using 20 µL volumes. Besides, the use of a smartphone to capture images followed by analysis in a free app offers simplicity to all users. The proposed methodology arises as a new strand to be exploited in the diffusion of the analytical chemistry education field as well as an alternative for quantitative analysis with extremely simplified instrumentation.

  5. Simultaneous determination of equivalence volumes and acid dissociation constants from potentiometric titration data.

    Science.gov (United States)

    Papanastasiou, G; Ziogas, I

    1995-06-01

    New iterative methods for analysis of potentiometric titration data of (a) mixtures of weak monoprotic acids with their conjugate bases, (b) solutions of polyprotic (di- and triprotic) acids, and (c) mixtures of two diprotic acids are presented. These methods, using data exclusively resulting from the acidic region of the titration curve permits the accurate determination of the analytical concentration of one or more acids even if the titration is stopped well before the end point of the titration. For the titration of a solution containing a conjugate acid/base pair, the proposed procedure enables the extraction of the initial composition of the mixture, as well as the dissociation constant of the concerned acid. Thus, it is possible by this type of analysis to distinguish whether a weak acid has been contaminated by a strong base and define the extent of the contamination. On the other hand, for the titration of polyprotic acids, the proposed approach enables the extraction of the accurate values of the equivalence volume and the dissociation constants K(i) even when the ionization stages overlap. Finally, for the titration of a mixture of two diprotic acids the proposed procedure enables the determination of the composition of the mixture even if the sum of the concentrations of the acids is not known. This method can be used in the analysis of solutions containing two diastereoisomeric forms of a weak diprotic acid. The test of the proposed procedures by means of ideal and Monte Carlo simulated data revealed that these methods are fairly applicable even when the titration data are considerably obscured by 'noise' or contain an important systematic error. The proposed procedures were also successfully applied to experimental titration data.

  6. Implementation of a pharmacist-managed heart failure medication titration clinic.

    Science.gov (United States)

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  7. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    Science.gov (United States)

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Predicting proton titration in cationic micelle and bilayer environments

    Science.gov (United States)

    Morrow, Brian H.; Eike, David M.; Murch, Bruce P.; Koenig, Peter H.; Shen, Jana K.

    2014-08-01

    Knowledge of the protonation behavior of pH-sensitive molecules in micelles and bilayers has significant implications in consumer product development and biomedical applications. However, the calculation of pKa's in such environments proves challenging using traditional structure-based calculations. Here we apply all-atom constant pH molecular dynamics with explicit ions and titratable water to calculate the pKa of a fatty acid molecule in a micelle of dodecyl trimethylammonium chloride and liquid as well as gel-phase bilayers of diethyl ester dimethylammonium chloride. Interestingly, the pKa of the fatty acid in the gel bilayer is 5.4, 0.4 units lower than that in the analogous liquid bilayer or micelle, despite the fact that the protonated carboxylic group is significantly more desolvated in the gel bilayer. This work illustrates the capability of all-atom constant pH molecular dynamics in capturing the delicate balance in the free energies of desolvation and Coulombic interactions. It also shows the importance of the explicit treatment of ions in sampling the protonation states. The ability to model dynamics of pH-responsive substrates in a bilayer environment is useful for improving fabric care products as well as our understanding of the side effects of anti-inflammatory drugs.

  9. Effect of a stirring process in an isothermal titration microcalorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Socorro, F.; Nuez, I. de la; Alvarez, L.; Rodriguez de Rivera, M

    2004-10-01

    In this paper, it is analysed the way in which the thermodynamic results obtained in an isothermal titration microcalorimeter, with continuous injection of a liquid and a variable mass are affected. Two aspects are presented, the first one refers to a variation in the baseline that takes place when the liquid mass is increased in the laboratory cell, this variation is due to the change in the thermal coupling between the stirrer and its contact with the thermostat. The second aspect is the analysis of the effect of the stirring process and the injection velocity on the homogenization of the remaining mixture in the laboratory cell. The aim of the study of these two previous aspects is to increase the accuracy of the thermodynamic measures carried out. The variation of the baseline affects in a percentage from 1 to 2% of the total energy developed. It is also shown the necessity of a stirring process according to the injection velocity in order to obtain a homogeneous mixture at every instant. This fact allows to carry out a deconvolution of the calorimetric signal and to obtain directly the power developed in the mixture process in terms of the amount of mixed substance [Meas. Sci. Technol. 1 (1990) pp. 1285-1290; J. Thermal Analysis 41 (1994) pp. 1385-1392].

  10. Monitoring Acid–Base Titrations on Wax Printed Paper Microzones Using a Smartphone

    OpenAIRE

    Sandro A. Nogueira; Lucas R. Sousa; Nathália K. L. Silva; Pedro H. F. Rodrigues; Wendell K. T. Coltro

    2017-01-01

    This study describes the use of a smartphone for monitoring acid–base titrations on wax printed paper microzones. An array of twelve microzones of 5 mm diameter each was wax printed on filter paper. The analytical performance of the proposed devices was explored with acid–base titrations examples, where jaboticaba peel extract was used as a natural pH indicator. The color intensity was captured using a smartphone and analyzed through a free App named Photometrix®. Before titrations, color int...

  11. Amperometric titration of thorium and some lanthanoids in acetic-acid medium using two indicator electrodes

    International Nuclear Information System (INIS)

    Khadeev, V.A.; Gevorgyan, A.M.; Talipov, Sh.T.; Kostylev, V.S.

    1979-01-01

    The votammetric behaviour of nitriletrimethylphosphonic acid (NTMP) in the medium of anhydrous acetic acid with different backgrounds in the anode region of polarization of a platinum microdisk electrode, is studied. The optimal conditions are found for the amperometric titration with two indicator electrodes of thorium and same lanthanides by a NTMP solution in anhydrous acetic medium. The influence of foreign anions and cations on the results of titration by the NTPM solution in anhydrous acetic acid is studied. The selectivity of titration in anhydrous medium is higher than in aqueous

  12. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    OpenAIRE

    Lorentz JÄNTSCHI; Horea Iustin NAŞCU

    2002-01-01

    The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titra...

  13. On the Physical Meaning of the Isothermal Titration Calorimetry Measurements in Calorimeters with Full Cells

    Science.gov (United States)

    Grolier, Jean-Pierre E.; del Río, Jose Manuel

    2009-01-01

    We have performed a detailed study of the thermodynamics of the titration process in an isothermal titration calorimeter with full cells. We show that the relationship between the enthalpy and the heat measured is better described in terms of the equation Δ H = Winj + Q (where Winj is the work necessary to carry out the titration) than in terms of ΔH = Q. Moreover, we show that the heat of interaction between two components is related to the partial enthalpy of interaction at infinite dilution of the titrant component, as well as to its partial volume of interaction at infinite dilution. PMID:20054472

  14. Characterization of antibody-chelator conjugates: Determination of chelator content by terbium fluorescence titration

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, K.D.; Schnobrich, K.E.; Johnson, D.K. (Abbott Laboratories, Department 90M, Abbott Park, IL (United States))

    1991-01-01

    Fluorescence titrations were performed by adding varying mole ratios of terbium(III) to antibody conjugates formed by benzyl isothiocyanate derivatives of three different polyaminopolycarboxylate chelators (NTA, EDTA, and DTPA) and the results compared to values for average chelator content obtained by cobalt-57 binding assays. For two different murine monoclonal antibodies, the average chelator content obtained by terbium fluorescence titration correlated closely with that measured by the cobalt-57 binding assay. It is concluded that lanthanide fluorescence titrations provide a useful alternative to radiometal binding assays for the determination of chelator content in protein-chelator conjugates.

  15. Evaluation of Resin-Resin Interface in Direct Composite Restoration Repair

    Science.gov (United States)

    Stoleriu, S.; Andrian, S.; Pancu, G.; Nica, I.; Iovan, G.

    2017-06-01

    The aim of this study was to evaluate the resin-resin interface when a universal bonding agent was used in two different strategies in direct restoration repair. Two composite resins (a micro-filled hybrid and a nano-filled hybrid) as old restorations that have to be repair, a universal bonding agent and a micro-filled hybrid composite resin (different then that aged) as new material for repair were chosen for the study. Non-aged samples were used as control and aged samples were used as study groups. The universal bonding agent was applied in etch-and-rinse and in self-etch strategies. The interface between old and new composite resins was evaluated by SEM and the microleakage was assessed by scoring the dye penetration. Very good adaptation of the two different composite resins placed in direct contact in non-aged samples was recorded. No gaps or defects were visible and strong resin-resin contact was observed. After aging, enlargement of resin-resin junction were observed in most of the samples and a increased dye penetration was recorded irrespective of the strategy (etch-and-rinse or self-etch) used for bonding agent application.

  16. Effects of exposure to 4-META/MMA-TBB resin on pulp cell viability.

    Science.gov (United States)

    Imaizumi, Nakako; Kondo, Hisatomo; Ohya, Keiichi; Kasugai, Shohei; Araki, Kouji; Kurosaki, Norimasa

    2006-06-01

    Adhesive restorative systems have expanded the range of possibilities for direct pulp-capping technique, with evidences of clinical success in vital pulp therapy. However, quite few studies have described the direct responses of pulp cells following the application of resinous materials to pulp exposure. To address this issue, effects of exposure to an adhesive resin, 4-methacryloxyethyl trimellitate anhydride/methyl methacrylate-tri-n-butyl borane (4-META/MMA-TBB) resin on cellular activity were investigated in an established rat dental pulp cell line (RPC-C2A). RPC-C2A cells were cultured on normal plastic plates or the disks prepared from 4-META/MMA-TBB resin (Super Bond C&B) in a-MEM containing 10% FBS. After 3, 7 and 14 days, DNA content and alkaline phosphatase (ALP) activity were measured. Total RNA in each group was extracted and RT-PCR analysis was performed. Moreover, the live cell ratio was also evaluated by cytotoxicity assay after treatment with various concentrations of 4-META/MMA-TBB. At day 3, 7 and 14, amount of DNA and ALP activity of the cells on normal plastic plates and the one on the 4-META/MMA-TBB were comparable. Cells of both groups expressed mRNA of type I collagen (Coll), ALP, osteopontin (OPN), osteocalcin (OC), and bone morphogenetic protein (BMP-2). Furthermore, 4-META/MMA-TBB (10(-1)% or less) did not influence dead cell ratio in the confluent state. According to the results of these in vitro studies, exposure to this resinous material would not induce cytotoxic response in the pulp cells.

  17. Bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Hamanaka, Ippei; Shimizu, Hiroshi; Takahashi, Yutaka

    2017-01-01

    This study evaluated the shear bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins. Four kinds of injection-molded thermoplastic resins (two polyamides, a polyethylene terephthalate copolymer and a polycarbonate) and PMMA, as a control, were tested. The eight types of surface treatment: ((1) no treatment, (2) air abrasion, (3) dichloromethane, (4) ethyl acetate, (5) 4-META/MMA-TBB resin, (6) air abrasion and 4-META/MMA-TBB resin, (7) tribochemical silica coating, and (8) tribochemical silica coating and 4-META/MMA-TBB resin) were applied to each specimen. The chairside autopolymerizing reline resins were bonded to disks of the injection-molded thermoplastic denture base resins. All of the specimens were immersed in water for 4 months and then thermocycled for 10,000 cycles in water between 5 and 55°C. The shear bond strengths were determined. The shear bond strengths of the two polyamides treated using air abrasion, dichloromethane and ethyl acetate and no treatment were exceedingly low. The greatest bond strength was recorded for the polyethylene terephthalate copolymer specimens treated with tribochemical silica coating and 4-META/MMA-TBB resin (22.5MPa). The bond strengths of the other injection-molded thermoplastic denture base resins increased using 4-META/MMA-TBB resin. Tribochemical silica coating and 4-META/MMA-TBB resin were the most effective surface treatments among all denture base resins tested. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. Accurate and precise determination of 2-25mg amounts of uranium by means of a special automatic potentiometric titration

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Groen, A.J.P.; Lingerak, W.A.

    1978-01-01

    A precise and accurate potentiometric titration of 2-25 mg of uranium is described. The uranium is reduced to U(IV) according to the method of Eberle et al. [3], and titrated with 0.05 N potassium dichromate, using a platinum indicator electrode. During the sample preparation the walls of the titration vessel are cleaned by centrifugation. To avoid overshoot of the set point a special differentiator is described, that interrupts the titration until equilibrium is reached. The precision of the method is 0.02%, the accuracy is better than 0.04% rel. Each titration takes 5 min. (orig.) [de

  19. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  20. GOKaRT: Graphical Online Search Tool for Maps

    Directory of Open Access Journals (Sweden)

    Mechthild Schüler

    2008-09-01

    Full Text Available The map department of the Staats- und Universitätsbibliothek Göttingen together with the Berlin State Library propose a project to develop a web-based graphic cataloguing and search system for maps, to be funded by the German Research Foundation. This tool shall be made available to all map holdings in archives, libraries, university departments and museums in Germany as a comfortable means for the administration of map holdings and as a search tool. Sheets belonging to map series as well as single maps (old and new will be registered cooperatively by the participants with simple tools. This cooperation in data maintenance will facilitate the work especially for understaffed map holdings. Depending on the type of map there are four different mechanisms for map reference. For map series electronic index sheets are used which will show information regarding the various issues of the map sheets. Due to the intuitive graphic search entry GOKaRT-users will easily find the required maps of a certain region available in a chosen holding. User administration modules ensure comfortable handling. GOKaRT is being developed on the basis of licence-free open source programmes. In case financing is provided by the German Research Foundation, GOKaRT can be used free of charge internationally. This would require a contract stipulating data exchange between the partners as well as permanent storage and usability of the data.

  1. WE-H-207B-00: MRgRT

    International Nuclear Information System (INIS)

    2016-01-01

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A

  2. WE-H-207B-04: Strategies for Adaptive RT

    International Nuclear Information System (INIS)

    Green, O.

    2016-01-01

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A

  3. Mineralogy of fossil resins in Northern Eurasia

    Science.gov (United States)

    Bogdasarov, M. A.

    2007-12-01

    The investigation is focused on identification and origin of fossil resins from the Cretaceous, Tertiary, and Quaternary sediments of Northern Eurasia on the basis of detailed study of their physical and chemical characteristics: morphology; size; mass; density; optical, mechanical, and thermal properties; chemical composition; etc. The composition of amorphous organic minerals with polymeric structure, fossil resins included, is studied with IR spectrometry, the EPR method, derivatography at low heating rates, XRD, chemical analysis, emission spectrometry, etc. The results of investigation summarized for the Baltic-Dnieper, North Siberian, and Far East amber-bearing provinces show some similarity of fossil resins in combination with specific features inherent to each province. Resins from the Baltic-Dnieper province should be termed as amber (succinite). Their variety is the most characteristic of Northern and Eastern Europe. Amber-like fossil resins from the North Siberian and Far East provinces are irrelevant to succinite. They usually occur as brittle resins, namely, retinite and gedanite, without jewelry value. Viscous fossil resin rumänite with an expected high economic value occurs in the Far East, on the shore of Sakhalin Island.

  4. Investigation of fossil resins and amber

    Directory of Open Access Journals (Sweden)

    E.Yu. Makarova

    2017-05-01

    Full Text Available Fossil resins and amber are a product of lithogenesis of resinous substances of higher plants – resinite. These components of plants, like other lipoid ingredients (suberins, coutines, sporinins, natural rubbers are resistant to microbial action, so they are well preserved in bacterial processing of organic matter in the stages of sedimento- and diagenesis, and are well diagnosed in microscopic studies. They occur in a rather wide age range of sedimentary rocks. The amber of the Baltic region of the Eocene age is most fully studied. The article presents the results of a study of the collection of fossil resins and amber from various regions of the world. Samples were studied microscopically; carbon isotope analysis, infrared spectroscopy (IR spectroscopy were performed. The most informative analysis of high-molecular polymeric compounds is IR spectroscopy. It was found that in the analyzed samples of fossil resins of different ages, aromatic compounds are not observed, most of which are first volatilized in fossilization processes. The possibility of influencing the group composition of amber and amber-like resins for sedimentation, diagenesis and catagenesis is discussed. The IR spectra of fossil and modern resin conifers are compared. Using the IR spectroscopy method, an attempt was made to identify the botanical origin of fossil resins.

  5. Melamine-modified urea formaldehyde resin for bonding particleboards

    Science.gov (United States)

    Chung-Yun Hse; Feng Fu; Hui Pan

    2008-01-01

    For the development of a cost-effective melamine-modified urea formaldehyde resin (MUF), the study evaluated the effects of reaction pH and melamine content on resin properties and bond performance of the MUF resin adhesive systems. Eight resins, each with three replicates, were prepared in a factorial experiment that included two formulation variables: two reaction...

  6. Traumatic resin ducts as indicators of bark beetle outbreaks

    Science.gov (United States)

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  7. A Computer-Based Simulation of an Acid-Base Titration

    Science.gov (United States)

    Boblick, John M.

    1971-01-01

    Reviews the advantages of computer simulated environments for experiments, referring in particular to acid-base titrations. Includes pre-lab instructions and a sample computer printout of a student's use of an acid-base simulation. Ten references. (PR)

  8. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    Science.gov (United States)

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  9. Titration of Alanine Monitored by NMR Spectroscopy: A Biochemistry Laboratory Experiment

    Science.gov (United States)

    Waller, Francis J.; And Others

    1977-01-01

    The experiment described here involves simultaneous monitoring of pH and NMR chemical shifts during an aqueous titration of alpha- and beta-alanine. This experiment is designed for use in an undergraduate biochemistry course. (MR)

  10. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    Science.gov (United States)

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements

  11. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  12. Properties of a nanodielectric cryogenic resin

    Energy Technology Data Exchange (ETDEWEB)

    Polyzos, Georgios [ORNL; Tuncer, Enis [ORNL; Sauers, Isidor [ORNL; More, Karren Leslie [ORNL

    2010-01-01

    Physical properties of a nanodielectric composed of in situ synthesized titanium dioxide (TiO{sub 2}) nanoparticles ({le} 5 nm in diameter) and a cryogenic resin are reported. The dielectric losses were reduced by a factor of 2 in the nanocomposite, indicating that the presence of small TiO{sub 2} nanoparticles restricted the mobility of the polymer chains. Dielectric breakdown data of the nanodielectric was distributed over a narrower range than that of the unfilled resin. The nanodielectric had 1.56 times higher 1% breakdown probability than the resin, yielding 0.64 times thinner insulation thickness for the same voltage level, which is beneficial in high voltage engineering.

  13. SEM and elemental analysis of composite resins

    International Nuclear Information System (INIS)

    Hosoda, H.; Yamada, T.; Inokoshi, S.

    1990-01-01

    Twenty-four chemically cured, 21 light-cured anterior, three light-cured anterior/posterior, and 18 light-cured posterior composite resins were examined using scanning electron microscopy, and the elemental composition of their filler particles was analyzed with an energy dispersive electron probe microanalyzer. According to the results obtained, the composite resins were divided into five groups (traditional, microfilled type, submicrofilled type, hybrid type, and semihybrid), with two additional hypothetical categories (microfilled and hybrid). Characteristics of each type were described with clinical indications for selective guidance of respective composite resins for clinical use

  14. In-depth disinfection of acrylic resins.

    Science.gov (United States)

    Chau, V B; Saunders, T R; Pimsler, M; Elfring, D R

    1995-09-01

    This study demonstrated that bacteria penetrate three kinds of dental acrylic resin after a short time period. Samples of acrylic resin were contaminated with a variety of bacteria and were then placed in three different disinfecting solutions as directed by the manufacturers. After the specific dilution and immersion time, cultures were made from the resin samples. The only effective disinfectant was a 0.525% solution of sodium hypochlorite at a 10-minute immersion. It disinfected not only the surfaces but also the bacteria that penetrated the surfaces to a depth of 3 mm.

  15. Immobilisation of ion exchange resins in cement

    International Nuclear Information System (INIS)

    Howard, C.G.; Jolliffe, C.B.; Lee, D.J.

    1990-09-01

    The removal of activity from spent decontaminating solutions eg LOMI can be achieved using organic ion exchange resins. These resins can be successfully immobilised in cement based matrices. The optimum cement system contained 10% ordinary Portland cement 84% gg blast furnace slag, 6% microsilica with a water cement ratio of 0.5 and a dry resin loading of 36% with respect to total weight. This formulation was successfully scaled up to 200 litres giving a product with acceptable compressive strength, dimensional stability and elastic modulus. Storage of samples under water appears to have no detrimental effects on the product's properties. (author)

  16. Cobalt Ions Improve the Strength of Epoxy Resins

    Science.gov (United States)

    Stoakley, D. M.; St. Clair, A. K.

    1986-01-01

    Technique developed for improving mechanical strength of epoxy resins by adding cobalt ions in form of tris(acetylacetonato)cobalt (III) complex. Solid cast disks prepared from cobalt ion-containing epoxy resins tested for flexural strength and stiffness. Incorporation of cobalt ions into epoxies increased flexural strength of resins by 10 to 95 percent. Suitable resins for this technique include any liquid or solid TGMDA resins. Improved epoxy formulation proves useful as composite matrix resin, adhesive, or casting resin for applications on commercial and advanced aircraft.

  17. Microchemical analysis of materials based on Y-Ba-Cu by spectrophotometric titration

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.; Zakharov, Eh.K.

    1990-01-01

    A complex method for analysis of superconductor and similar materials on Y-Ba-Cu basis has been developed, which comprises yttrium and copper determination by their indicator spectrophotometric titration by EDTA and/or complexone 4 in the presence of arsenazo 3. The use of complexone 4 is more favourable. Titration is carried out at λ=650 nm. The method has a sufficient accuracy, provides for rapid determination and does not reguire preliminary separation of components

  18. Determination of opium and strychnos alkaloids by radiometric titrations with potassium thallium(I) iodide reagent

    International Nuclear Information System (INIS)

    Rama Rao, V.V.; Singh, N.J.; Tandon, S.N.

    1980-01-01

    The titrations were carried out by the batch method in test tubes, using 204 Tl-labelled potassium thallium(I) iodide as precipitant for alkaloids such as codeine, morphine, narcotine, papaverine, thebaine, strychnine and brucine. Direct and reverse titrations were investigated including sensitivity and accuracy. Codeine and narcotine were determined in some pharmaceutical preparations such as codeine sulfate tablets, codopyrin tablets and coscopin syrup

  19. Pulmonary acute respiratory distress syndrome: positive end-expiratory pressure titration needs stress index.

    Science.gov (United States)

    Huang, Yingzi; Yang, Yi; Chen, Qiuhua; Liu, Songqiao; Liu, Ling; Pan, Chun; Yang, Congshan; Qiu, Haibo

    2013-11-01

    The heterogeneity of lung injury in pulmonary acute respiratory distress syndrome (ARDS) may have contributed to the greater response of hyperinflated area with positive end-expiratory pressure (PEEP). PEEP titrated by stress index can reduce the risk of alveolar hyperinflation in patients with pulmonary ARDS. The authors sought to investigate the effects of PEEP titrated by stress index on lung recruitment and protection after recruitment maneuver (RM) in pulmonary ARDS patients. Thirty patients with pulmonary ARDS were enrolled. After RM, PEEP was randomly set according to stress index, oxygenation, static pulmonary compliance (Cst), or lower inflection point (LIP) + 2 cmH2O strategies. Recruitment volume, gas exchange, respiratory mechanics, and hemodynamic parameters were collected. PEEP titrated by stress index (15.1 ± 1.8 cmH2O) was similar to the levels titrated by oxygenation (14.5 ± 2.9 cmH2O), higher than that titrated by Cst (11.3 ± 2.5 cmH2O) and LIP (12.9 ± 1.6 cmH2O) (P stress index and oxygenation but higher than that titrated by Cst and LIP. Compared with baseline, lung compliance increased significantly when PEEP determined by Cst, but there was no difference of Cst in these four strategies. There was no influence of PEEP titration with the four strategies on hemodynamic parameters. PEEP titration by stress index might be more beneficial for pulmonary ARDS patients after RM. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    Science.gov (United States)

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Determination of the aggregation number for micelles by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Olesen, Niels Erik; Holm, Rene; Westh, Peter

    2014-01-01

    Isothermal titration calorimetry (ITC) has previously been applied to estimate the aggregation number (n), Gibbs free energy (ΔG), enthalpy (ΔH) and entropy (ΔS) of micellization. However, some difficulties of micelle characterization by ITC still remain; most micelles have aggregation numbers...... insight into optimal design of titration protocols for micelle characterization. By applying the new method, the aggregation number of sodium dodecyl sulphate and glycochenodeoxycholate was determined at concentrations around their critical micelle concentration (CMC)...

  2. Potentiometric titration of zinc and cadmium in electrolytes of in galvanic baths

    International Nuclear Information System (INIS)

    Kosyuga, E.A.; Kalugin, A.A.; Gur'ev, I.A.

    1979-01-01

    The method of potentiometric titration of zinc and cadmium by complexone 3 in electrolytes of galvanic baths using sulphide - silver electrode for determining the finite point of titration is suggested. Copper (2) ions are proposed as indicator ions. The potentiometric determination should be performed at pH=10. The method is verified on model electrolyte solutions and on the electrolyte solutions of operating baths.The technique can be used for automatic control. The time for analysis is 10 minutes

  3. Shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Hamanaka, Ippei; Shimizu, Hiroshi; Takahashi, Yutaka

    2013-09-01

    This study investigated the shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins. Four injection-molded thermoplastic resins (two polyamides, a polyethylene terephthalate copolymer and a polycarbonate) were used in this study. The specimens were divided into eight groups according to the type of surface treatment given: (1) no treatment, (2) air abrasion with alumina, (3) dichloromethane, (4) ethyl acetate, (5) 4-META/MMA-TBB resin, (6) alumina and 4-META/MMA-TBB resin, (7) tribochemical silica coating or (8) tribochemical silica coating and 4-META/MMA-TBB resin. Half of the specimens in groups 1, 5, 6 and 8 were thermocycled for 10,000 cycles in water between 5-55°C with a dwell time of 1 min at each temperature. The shear bond strengths were determined. The shear bond strengths to the two polyamides treated with alumina, dichloromethane and ethyl acetate and no treatment were very low. The greatest post-thermocycling bond strengths to polyamides were recorded for the specimens treated with tribochemical silica coating and 4-META/MMA-TBB resin (PA12: 16.4 MPa, PACM12: 17.5 MPa). The greatest post-thermocycling bond strengths to polyethylene terephthalate copolymer and polycarbonate were recorded for the treatment with alumina and 4-META/MMA-TBB resin (22.7 MPa, 20.8 MPa). Polyamide was exceedingly difficult to bond to an autopolymerizing repair resin; the shear bond strength improved using tribochemical silica coating followed by the application of 4-META/MMA-TBB resin. Both polyethylene terephthalate copolymer and polycarbonate were originally easy to bond to an autopolymerizing repair resin. However, with 4-META/MMA-TBB resin, the bond was more secure.

  4. Magnetic ion-exchange resin treatment: Impact of water type and resin use

    OpenAIRE

    Mergen, Maxime Rodolphe Denis; Jefferson, Bruce; Parsons, Simon A.; Jarvis, Peter

    2008-01-01

    Three raw waters of fundamentally different natural organic matter (NOM) character were treated by magnetic resin using a bench-scale method designed to mimic how the resin is used in continuous operation. Increasing water hydrophobicity resulted in reduced dissolved organic carbon (DOC) removal with removal of 56%, 33% and 25% for waters containing 21%, 50% and 75% hydrophobic NOM, respectively. Study of consecutive resin uses showed that the NOM in the hydrophobic water ha...

  5. 5-year clinical performance of resin composite versus resin modified glass ionomer restorative system in non-carious cervical lesions

    DEFF Research Database (Denmark)

    Franco, Eduardo Batista; Benetti, Ana Raquel; Ishikiriama, Sérgio Kiyoshi

    2006-01-01

    To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions.......To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions....

  6. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Science.gov (United States)

    2010-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  7. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    Directory of Open Access Journals (Sweden)

    Grace Wu

    Full Text Available Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration.To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia.Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration.Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3, respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute.Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  8. Titration of strong and weak acids by sequential injection analysis technique.

    Science.gov (United States)

    Maskula, S; Nyman, J; Ivaska, A

    2000-05-31

    A sequential injection analysis (SIA) titration method has been developed for acid-base titrations. Strong and weak acids in different concentration ranges have been titrated with a strong base. The method is based on sequential aspiration of an acidic sample zone and only one zone of the base into a carrier stream of distilled water. On their way to the detector, the sample and the reagent zones are partially mixed due to the dispersion and thereby the base is partially neutralised by the acid. The base zone contains the indicator. An LED-spectrophotometer is used as detector. It senses the colour of the unneutralised base and the signal is recorded as a typical SIA peak. The peak area of the unreacted base was found to be proportional to the logarithm of the acid concentration. Calibration curves with good linearity were obtained for a strong acid in the concentration ranges of 10(-4)-10(-2) and 0.1-3 M. Automatic sample dilution was implemented when sulphuric acid at concentration of 6-13 M was titrated. For a weak acid, i.e. acetic acid, a linear calibration curve was obtained in the range of 3x10(-4)-8x10(-2) M. By changing the volumes of the injected sample and the reagent, different acids as well as different concentration ranges of the acids can be titrated without any other adjustments in the SIA manifold or the titration protocol.

  9. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    Science.gov (United States)

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  10. Titration of fatty acids solubilized in cationic and anionic micelles. Calorimetry and thermodynamic modeling.

    Science.gov (United States)

    Söderman, Olle; Jönsson, Bengt; Olofsson, Gerd

    2006-02-23

    The electrostatic properties of charged surfactant micelles are investigated through titrations of fatty acid probes solubilized in the micelles. The titration process is followed by means of calorimetric measurements and by determining the pH values as a function of added base. This approach yields a complete thermodynamic description of the titration process. In particular, we find that the process is endothermic at 298 K. This is contrary to the titration of carboxylic acids in water, where DeltaH is approximately 0. To identify the main effect underlying the difference in DeltaH between titration in a micelle and water, a thermodynamic model has been developed which focuses on the transfer properties of charged and uncharged species from bulk water to the surface of a micelle and which incorporates a dielectric discontinuity at the micellar surface. The model relies on the use of the Poisson-Boltzmann equation which is solved using a finite element method. Experimental results and the model calculations imply that the dielectric discontinuity at (or near) the micellar surface plays a major role and hence must be included when analyzing the titration behavior of an acid functionality at the surface of a charged micelle.

  11. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    Science.gov (United States)

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (ptitration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    International Nuclear Information System (INIS)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    2017-01-01

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  13. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  14. Determination of free acid in U(VI)-Al(III) solution by Gran plot titration

    International Nuclear Information System (INIS)

    Suh, Moo Yul; Lee, Chang Heon; Sohn, Se Chul; Kim, Jung Suk; Kim, Won Ho; Eom, Tae Yoon

    1999-01-01

    The determination method of free acid in spent U-Al nuclear fuel solutions by Gran plot titration was described. Effect of U(VI) and Al(III) on the alkalimetric titration of nitric acid was investigation in oxalate complexing media as well as in noncomplexing media. Positive biases were observed in both titration media when the end-point was estimated by the Gran plot method. It was found that the cause of the bias was U(VI) in the oxalate complexing media, but Al(III) in the noncomplexing media. The relative error was less than 1% in the titration of 0.1 M HNO 3 at a U(VI):Al(III):H + mole ratio of up to 2:12:1 as long as the pH of the oxalate titration media was sustained to be below 5.0 at the beginning of titration. The method was successfully applied to the determination of nitric acid in a solution of HANARO reactor fuel with U:Al mole ratio of 1:6

  15. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, Daniel H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  16. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    International Nuclear Information System (INIS)

    Asakai, Toshiaki; Hioki, Akiharu

    2011-01-01

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  17. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    International Nuclear Information System (INIS)

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  18. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    Science.gov (United States)

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute. Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  19. The strengthening of resin cemented dental ceramic materials

    OpenAIRE

    Hooi, Paul

    2013-01-01

    The aim of the current investigation was to advance the understanding of the mechanism of resin-strengthening conferred to dental ceramic materials by resin-based composite materials. The investigation is presented as a series of manuscripts. In the first study (Manuscript 3.1), dental porcelain disc-shaped specimens were resin-coated with three resin-based composite materials with different flexural moduli at discrete resin thicknesses. The discs were loaded to failure in a biaxial flexure t...

  20. Pengaruh Sifat-Sifat Fisik Resin Akrilik Terhadap Basis Protesa

    OpenAIRE

    Amriani Syahfitri

    2008-01-01

    Saat ini resin akrilik banyak digunakan secara umum untuk konstruksi gigi tiruan. Sebagai bahan basis prothesa, penggunaan resin akrilik terutama resin heat cured adalah yang paling sering digunakan selain bernilai estetis, juga lebih ekonomis. Pada prothesa yang ideal memerlukan suatu basis yang kuat, Syarat- syarat basis protesa tidak semuanya dapat dipenuhi oleh basis resin akrilik. Sifat-sifat fisik resin akrilik mempunyai pengaruh terhadap basis protesa. Untuk menghindari k...

  1. Resin Flow Analysis in the Injection Cycle of a Resin Transfer Molded Radome

    Science.gov (United States)

    Golestanian, Hossein; Poursina, Mehrdad

    2007-04-01

    Resin flow analysis in the injection cycle of an RTM process was investigated. Fiberglass and carbon fiber mats were used as reinforcements with EPON 826 epoxy resin. Numerical models were developed in ANSYS finite element software to simulate resin flow behavior into a mold of conical shape. Resin flow into the woven fiber mats is modeled as flow through porous media. The injection time for fiberglass/epoxy composite is found to be 4407 seconds. Required injection time for the carbon/epoxy composite is 27022 seconds. Higher injection time for carbon/epoxy part is due to lower permeability value of the carbon fibers compared to glass fiber mat.

  2. Dental repair material: a resin-modified glass-ionomer bioactive ionic resin-based composite.

    Science.gov (United States)

    Croll, Theodore P; Berg, Joel H; Donly, Kevin J

    2015-01-01

    This report documents treatment and repair of three carious teeth that were restored with a new dental repair material that features the characteristics of both resin-modified glass-ionomer restorative cement (RMGI) and resin-based composite (RBC). The restorative products presented are reported by the manufacturer to be the first bioactive dental materials with an ionic resin matrix, a shock-absorbing resin component, and bioactive fillers that mimic the physical and chemical properties of natural teeth. The restorative material and base/liner, which feature three hardening mechanisms, could prove to be a notable advancement in the adhesive dentistry restorative materials continuum.

  3. Nanosilica Modification of Elastomer-Modified VARTM Epoxy Resins for Improved Resin and Composite Toughness

    National Research Council Canada - National Science Library

    Robinette, Jason; Bujanda, Andres; DeSchepper, Daniel; Dibelka, Jessica; Costanzo, Philip; Jensen, Robert; McKnight, Steven

    2007-01-01

    Recent publications have reported a synergy between rubber and silica in modified epoxy resins that results in significantly improved fracture toughness without reductions in other material properties...

  4. Synthesis of improved phenolic and polyester resins

    Science.gov (United States)

    Delano, C. B.

    1980-01-01

    Thirty-seven cured phenolic resin compositions were prepared and tested for their ability to provide improved char residues and moisture resistance over state of the art epoxy resin composite matrices. Cyanate, epoxy novolac and vinyl ester resins were investigated. Char promoter additives were found to increase the anaerobic char yield at 800 C of epoxy novolacs and vinyl esters. Moisture resistant cyanate and vinyl ester compositions were investigated as composite matrices with Thornel 300 graphite fiber. A cyanate composite matrix provided state of the art composite mechanical properties before and after humidity exposure and an anaerobic char yield of 46 percent at 800 C. The outstanding moisture resistance of the matrix was not completely realized in the composite. Vinyl ester resins showed promise as candidates for improved composite matrix systems.

  5. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    Purpose/aim: To evaluate in a randomized controlled study the 5-year clinical durability of a flowable resin composite bulk-fill technique in Class I and Class II restorations. Materials and methods: 38 pairs Class I and 62 pairs Class II restorations were placed in 44 male and 42 female (mean age...... 52.4 years). Each patient received at least two, as similar as possible, extended Class I or Class II restorations. In all cavities, a 1-step self-etch adhesive (Xeno V+) was applied. Randomized, one of the cavities of each pair received the flowable bulk-filled resin composite (SDR), in increments...... up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...

  6. 21 CFR 177.1380 - Fluorocarbon resins.

    Science.gov (United States)

    2010-04-01

    ...) Chlorotrifluoroethylene-1,1-difluoroethylene-tetrafluoroethylene co-polymer resins produced by copolymerization of..., Extrusion, and Coating Materials,” which is incorporated by reference in accordance with 5 U.S.C. 552(a) and...

  7. Liquid Resins With Low VOC Emissions

    National Research Council Canada - National Science Library

    LaScala, John J; Sands, James M; Palmese, Guiseppe R

    2004-01-01

    .... The polymer properties were similar to that of commercial resins, including Tg greater than 120 C, flex strength greater than 100 MPa, modulus of approximately 3 GPa, and fracture toughness greater than 200 J/m2...

  8. 21 CFR 177.1655 - Polysulfone resins.

    Science.gov (United States)

    2010-04-01

    ... by osmotic pressure in monochlorobenzene; or (2) 1,1′-Sulfonylbis[4-chlorobenzene] polymer with 4,4... determined by osmotic pressure in dimethylformamide. (b) The basic polysulfone resins identified in paragraph...

  9. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  10. Cycloaliphatic epoxide resins for cationic UV - cure

    International Nuclear Information System (INIS)

    Verschueren, K.; Balwant Kaur

    1999-01-01

    This paper introduces the cyclo - aliphatic epoxide resins used for the various applications of radiation curing and their comparison with acrylate chemistry. Radiation curable coatings and inks are pre - dominantly based on acrylate chemistry but over the last few years, cationic chemistry has emerged successfully with the unique properties inherent with cyclo - aliphatic epoxide ring structures. Wide variety of cationic resins and diluents, the formulation techniques to achieve the desired properties greatly contributes to the advancement of UV - curing technology

  11. Damage evolution in a filled epoxy resin

    International Nuclear Information System (INIS)

    Depoorter, Nicolas; Coutellier, Daniel; Muzic, Markus; Berg-Pollack, Antje; Cai Ye; Zimmermann, Andre

    2006-01-01

    A method is proposed for studying damage evolution in a filled epoxy resin submitted to low-cycle fatigue loading. Transmission electron microscopy analysis was performed, which indicates a damage mechanism that corresponds well to the decreasing slope of the stress-strain hysteresis observed in strain-controlled fatigue experiments. Also, the suggested damage model appears to be suitable for the simulation of strain-controlled cyclic tests and fits the damage evolution of the filled epoxy resin fairly well [de

  12. Detection and Analysis of Circular RNAs by RT-PCR.

    Science.gov (United States)

    Panda, Amaresh C; Gorospe, Myriam

    2018-03-20

    Gene expression in eukaryotic cells is tightly regulated at the transcriptional and posttranscriptional levels. Posttranscriptional processes, including pre-mRNA splicing, mRNA export, mRNA turnover, and mRNA translation, are controlled by RNA-binding proteins (RBPs) and noncoding (nc)RNAs. The vast family of ncRNAs comprises diverse regulatory RNAs, such as microRNAs and long noncoding (lnc)RNAs, but also the poorly explored class of circular (circ)RNAs. Although first discovered more than three decades ago by electron microscopy, only the advent of high-throughput RNA-sequencing (RNA-seq) and the development of innovative bioinformatic pipelines have begun to allow the systematic identification of circRNAs (Szabo and Salzman, 2016; Panda et al ., 2017b; Panda et al ., 2017c). However, the validation of true circRNAs identified by RNA sequencing requires other molecular biology techniques including reverse transcription (RT) followed by conventional or quantitative (q) polymerase chain reaction (PCR), and Northern blot analysis (Jeck and Sharpless, 2014). RT-qPCR analysis of circular RNAs using divergent primers has been widely used for the detection, validation, and sometimes quantification of circRNAs (Abdelmohsen et al ., 2015 and 2017; Panda et al ., 2017b). As detailed here, divergent primers designed to span the circRNA backsplice junction sequence can specifically amplify the circRNAs and not the counterpart linear RNA. In sum, RT-PCR analysis using divergent primers allows direct detection and quantification of circRNAs.

  13. Applications of LANCE Data at SPoRT

    Science.gov (United States)

    Molthan, Andrew

    2014-01-01

    Short term Prediction Research and Transition (SPoRT) Center: Mission: Apply NASA and NOAA measurement systems and unique Earth science research to improve the accuracy of short term weather prediction at the regional/local scale. Goals: Evaluate and assess the utility of NASA and NOAA Earth science data and products and unique research capabilities to address operational weather forecast problems; Provide an environment which enables the development and testing of new capabilities to improve short term weather forecasts on a regional scale; Help ensure successful transition of new capabilities to operational weather entities for the benefit of society

  14. SMAP Data Assimilation at NASA SPoRT

    Science.gov (United States)

    Blankenship, Clay B.; Case, Jonathan L.; Zavodsky, Bradley T.

    2016-01-01

    The NASA Short-Term Prediction Research and Transition (SPoRT) Center maintains a near-real- time run of the Noah Land Surface Model within the Land Information System (LIS) at 3-km resolution. Soil moisture products from this model are used by several NOAA/National Weather Service Weather Forecast Offices for flood and drought situational awareness. We have implemented assimilation of soil moisture retrievals from the Soil Moisture Ocean Salinity (SMOS) and Soil Moisture Active/ Passive (SMAP) satellites, and are now evaluating the SMAP assimilation. The SMAP-enhanced LIS product is planned for public release by October 2016.

  15. 47: A new RT-CT system for radiotherapy

    International Nuclear Information System (INIS)

    Tsujii, H.; Kamada, T.; Takamura, A.; Irie, G.; Ohta, H.; Kubo, Y.; Inamura, K.

    1987-01-01

    A new radiotherapy dedicated CT-system (RT-CT system) has been developed, allowing various aspects of radiotherapy including pre-treatment staging, treatment planning, treatment delivery and follow-up after irradiation. The hardwares include a CT scanner, laser-beam field projector, dose planning unit, independent diagnostic console, data processing and filing unit, and related accessories. The main feature of treatment planning involves the determination of radiation parameters using CT scans with or without a scout view, where a conventional X-ray simulator is no longer used. The system permits 3-D dose calculation with inhomogeneity corrections. 8 refs.; 4 figs

  16. Titrated flow versus fixed flow Bubble Nasal CPAP for respiratory distress in preterm neonates.

    Directory of Open Access Journals (Sweden)

    Srinivas eMurki

    2015-10-01

    Full Text Available Background: The clinical effects of a pre-fixed flow of air-oxygen versus a flow titrated according to visible bubbling are not well understood.Objective: To compare the effects of a fixed flow (5 L/min and titrated flow ( flow just enough to ensure bubbling at different set pressures on delivered intra-prong pressure, gas exchange and clinical parameters in preterm infants on bubble CPAP for respiratory distress.Methods: Preterm infants less than 35 weeks gestation on bubble CPAP and less than 96 h of age, were enrolled in this cross over study. They were subjected to 30 minute periods of titrated flow and fixed flow. At the end of both epochs, gas flow rate, set pressure, FiO2, SpO2, Silverman retraction score, respiratory rate , abdominal girth, and blood gases were recorded. The delivered intra-prong pressure was measured by an electronic manometer. Results: Sixty nine recordings were made in 54 infants. For each of the set CPAP pressures (4, 5 and 6 cm H2O, the mean delivered pressure with a fixed flow of 5 L/min was higher than that delivered by the titrated flow. During the fixed flow epoch, the delivered pressure was closer to and higher than the set pressure resulting in higher PaO2 and lower PaCO2 as compared to titrated flow epoch. In the titrated flow period, the delivered pressure was consistently lower than the set pressure. Conclusion: In preterm infants on bubble CPAP with set pressures of 4 to 6 cm H2O, a fixed flow of 5 L/min is more effective than a flow titrated to ensure adequate visible bubbling. It achieves higher delivered pressures, better oxygenation and ventilation.

  17. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    Science.gov (United States)

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  18. Imide modified epoxy matrix resins

    Science.gov (United States)

    Scola, D. A.

    1984-01-01

    The results of a program designed to develop tough imide modified epoxy resins cured by bisimide amine (BIA) hardeners are described. State-of-the-art epoxides MY720 and DER383 were used, and four bismide amines were evaluated. These were the BIA's derived from the 6F anhydride (4,4'-(hexafluoroisopropylidene) bis(phthalic anhydride) and the diamines 3,3'-diaminodiphynyl sulfone, 4,4'-oxygianiline, 4,4'-methylene dianiline, and 1,12-dodecane diamine. A key intermediate, designated 6F anhydride, is required for the synthesis of the bisimide amines. Reaction parameters to synthesize a precursor to the 6F anhydride (6FHC) in high yields were investigated. The catalyst trifluoromethane sulfonic acid was studied. Although small scale runs yielded the 6FHC in 50 percent yield, efforts to ranslate these results to a larger scale synthesis gave the 6FHC in only 9 percent yield. Results show that the concept of using bisimide amine as curing agents to improve the toughness properties of epoxies is valid.

  19. Resin elasticity and the strengthening of all-ceramic restorations.

    Science.gov (United States)

    Addison, O; Marquis, P M; Fleming, G J P

    2007-06-01

    Resin luting of all-ceramic restorations results in increased performance; however, the strengthening mechanism and the role of the mechanical properties of the resin are not fully understood. The hypothesis tested is that ceramic strength enhancement is dependent on the elastic modulus of the resin. Three-point flexural moduli of a flowable, luting, and hybrid composite resin were characterized. Two hundred forty porcelain discs were air-abraded. One group acted as a control, and 3 additional groups were coated with 120 +/- 20 microm of each resin prior to bi-axial flexure testing. All resins significantly increased in mean strength, and the associated strength increase was related to the elastic modulus of the resin (R(2) = 0.9885), so the hypothesis was accepted. The combination of Poisson constraint and the creation of a resin-inter-penetrating layer sensitive to the elastic modulus of the resin may provide an explanation of the strengthening mechanism.

  20. Effect of resin coating on dentin bonding of resin cement in Class II cavities.

    Science.gov (United States)

    Sultana, Shamim; Nikaido, Toru; Matin, Khairul; Ogata, Miwako; Foxton, Richard M; Tagami, Junji

    2007-07-01

    This study was designed to evaluate the efficacy of resin coating on the regional microtensile bond strength (MTBS) of a resin cement to the dentin walls of Class II cavities. Twenty mesio-occlusal cavities were prepared in human molars. In 10 cavities, a resin coating consisting of a self-etching primer bonding system, Clearfil SE Bond, and a low-viscosity microfilled resin, Protect Liner F, was applied. The other 10 teeth served as a non-coating group. After impression taking and temporization, they were kept in water for one day. Composite inlays were then cemented with a dual-cure resin cement, Panavia F 2.0, and stored in water for one day. Thereafter, MTBSs were measured. Two-way ANOVA (p=0.05) revealed that the MTBS of resin cement to dentin was influenced by resin coating, but not by regional difference. In conclusion, application of a resin coating to the dentin surface significantly improved the MTBS in indirect restorations.

  1. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    Directory of Open Access Journals (Sweden)

    Adilson Yoshio Furuse

    2007-12-01

    Full Text Available The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1 rinsing with water and drying; (G2 application of an adhesive system; (G3 rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4 rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (p<0.05. Similar values to the original bond strength were obtained after abrasion and application of adhesive (G3 or etching and application of silane and adhesive (G4. If contamination occurs, a surface treatment is required to guarantee an adequate interaction between the resin increments.

  2. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel

    2007-01-01

    of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin...

  3. Global Dynamics and International Cooperation Needs of RT Development and Utilization for the Establishment of the Northeast Asia RT Hub in Korea

    International Nuclear Information System (INIS)

    Kim, Y. K.; Oh, G. B.; Yun, S. W.; Yang, M. H.; Ryu, J. S.; Choi, S. J.; Choi, S. G.

    2005-11-01

    In an effort to achieve the objectives, the following scopes were categorized for in-depth study. First, analysis framework was developed for RT capacity development and international technology cooperation strategy. RT survey checklist and international technology cooperation was analyzed with interviewing and reports of domestic participants recently. Second, RT strategic environment was analyze for East-Asia hub competition/cooperation and developing nations using analysis framework. Korean RT was analyzed using SWOT analysis for establishment of RT hub in Korea. Third, East-Asian nations were classified analyzed by RT categories in standpoint of our country. Technology status and future cooperation plan were discussed about RT application for bio-medicine. Products/technology seminar related to an export was hold about support plan of admission/sales for functional food HemoHIM. This study can be utilized in the establishment of RT hub and development strategy. And it can be also utilized in promotion devising of domestic RT and planning setup for obtaing the international competitive power

  4. Global Dynamics and International Cooperation Needs of RT Development and Utilization for the Establishment of the Northeast Asia RT Hub in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. K.; Oh, G. B.; Yun, S. W.; Yang, M. H.; Ryu, J. S.; Choi, S. J.; Choi, S. G

    2005-11-15

    In an effort to achieve the objectives, the following scopes were categorized for in-depth study. First, analysis framework was developed for RT capacity development and international technology cooperation strategy. RT survey checklist and international technology cooperation was analyzed with interviewing and reports of domestic participants recently. Second, RT strategic environment was analyze for East-Asia hub competition/cooperation and developing nations using analysis framework. Korean RT was analyzed using SWOT analysis for establishment of RT hub in Korea. Third, East-Asian nations were classified analyzed by RT categories in standpoint of our country. Technology status and future cooperation plan were discussed about RT application for bio-medicine. Products/technology seminar related to an export was hold about support plan of admission/sales for functional food HemoHIM. This study can be utilized in the establishment of RT hub and development strategy. And it can be also utilized in promotion devising of domestic RT and planning setup for obtaing the international competitive power.

  5. Bulk-filled posterior resin restorations based on stress-decreasing resin technology

    DEFF Research Database (Denmark)

    van Dijken, Jan W.V.; Pallesen, Ulla

    2017-01-01

    This randomized study evaluated a flowable resin composite bulk-fill technique in posterior restorations and compared it intraindividually with a conventional 2-mm resin composite layering technique over a 6-yr follow-up period. Thirty-eight pairs of Class II restorations and 15 pairs of Class I...... restorations were placed in 38 adults. In all cavities a single-step self-etch adhesive (Xeno V) was applied. In the first cavity of each pair, the flowable resin composite (SDR) was placed, in bulk increments of up to 4 mm. The occlusal part was completed with a layer of nanohybrid resin composite (Ceram X...... mono). In the second cavity of each pair, the hybrid resin composite was placed in 2-mm increments. The restorations were evaluated using slightly modified US Public Health Service (USPHS) criteria at baseline and then annually for a time period of 6 yr. After 6 yr, 72 Class II restorations and 26...

  6. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    Science.gov (United States)

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This

  7. Thermal rearrangement of novolak resins used in microlithography

    Science.gov (United States)

    Hardy, Ricky; Zampini, Anthony; Monaghan, Michael J.; O'Leary, Michael J.; Cardin, William J.; Eugster, Timothy J.

    1995-06-01

    Changes in phenolic-formaldehyde resin properties are described in terms of thermal exposure. At high temperature, resin molecular weight, dissolution properties and chemical composition change depending on the presence or absence of monomers. Without monomer in the resin melt at 220 degree(s)C, resin molecular weight increases with a corresponding decrease in dissolution rate. In the presence of monomer, molecular weight generally decreases. Dissolution rate may fluctuate depending on the monomer mixture. Three,five- Xylenol and 2,3,5-trimethylphenol co-monomers induced the most extreme changes in resin properties with thermal treatment. Resin degradation-recombination processes suggest a classical Friedel-Craft rearrangement mechanism.

  8. New bismaleimide matrix resins for graphite fiber composites

    Science.gov (United States)

    Hsu, M.-T. S.; Chen, T. S.; Parker, J. A.; Heimbuch, A. H.

    1985-01-01

    Two new bismaleimide resins based on the N,N'-m-phenylene-bis(m-amino-benzamide) structure have been synthesized and characterized. The mixtures of the two resins gave better handling, processing, mechanical, and thermal properties in graphite composites than did the individual resins. The mechanical strength of the cured graphite composites prepared from the 1:1 copolymer of the two bismaleimide resins was excellent at both ambient and elevated temperatures. The physical and mechanical properties of the composites from the new bismaleimide matrix resin systems are compared with conventional composites based on epoxy and other bismaleimide systems. The copolymer system provides another method for improving bismaleimide resins.

  9. Thermal cycling effects on adhesion of resin-bovine enamel junction among different composite resins.

    Science.gov (United States)

    Chen, Wen-Cheng; Ko, Chia-Ling; Wu, Hui-Yu; Lai, Pei-Ling; Shih, Chi-Jen

    2014-10-01

    Thermal cycling is used to mimic the changes in oral cavity temperature experienced by composite resins when used clinically. The purpose of this study is to assess the thermal cycling effects of in-house produced composite resin on bonding strength. The dicalcium phosphate anhydrous filler surfaces are modified using nanocrystals and silanization (w/NP/Si). The resin is compared with commercially available composite resins Filtek Z250, Z350, and glass ionomer restorative material GIC Fuji-II LC (control). Different composite resins were filled into the dental enamel of bovine teeth. The bond force and resin-enamel junction graphical structures of the samples were determined after thermal cycling between 5 and 55°C in deionized water for 600 cycles. After thermal cycling, the w/NP/Si 30wt%, 50wt% and Filtek Z250, Z350 groups showed higher shear forces than glass ionomer GIC, and w/NP/Si 50wt% had the highest shear force. Through SEM observations, more of the fillings with w/NP/Si 30wt% and w/NP/Si 50wt% groups flowed into the enamel tubule, forming closed tubules with the composite resins. The push-out force is proportional to the resin flow depth and uniformity. The push-out tubule pore and resin shear pattern is the most uniform and consistent in the w/NP/Si 50wt% group. Accordingly, this developed composite resin maintains great mechanical properties after thermal cycling. Thus, it has the potential to be used in a clinical setting when restoring non-carious cervical lesions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A stable and convenient protein electrophoresis titration device with bubble removing system.

    Science.gov (United States)

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    International Nuclear Information System (INIS)

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  12. Management and Development of the RT Research Facilities and Infrastructures

    International Nuclear Information System (INIS)

    Kim, Won Ho; Nho, Young Chang; Kim, Jae Sung

    2009-01-01

    The purpose of this project are to operate the core facilities of the research for the Radiation Technology in stable and to assist the research activities efficiently in the industry, academic, and research laboratory. By developing the infrastructure of the national radio technology industry, we can activate the researching area of the RT and the related industry, and obtain the primary and original technology. The key point in the study of the RT and the assistance of the industry, academic, and research laboratory for the RT area smoothly, is managing the various of unique radiation facilities in our country. The gamma Phytotron and Gene Bank are essential in the agribiology because these facilities are used to preserve and utilize the genes and to provide an experimental field for the environment and biotechnology. The Radiation Fusion Technology research supporting facilities are the core support facilities, and are used to develop the high-tech fusion areas. In addition, the most advanced analytical instruments, whose costs are very high, should be managed in stable and be utilized in supporting works, and the experimental animal supporting laboratory and Gamma Cell have to be maintained in high level and managed in stable also. The ARTI have been developed the 30MeV cyclotron during 2005∼2006, aimed to produce radioisotopes and to research the beam applications as a result of the project, 'Establishment of the Infrastructure for the Atomic Energy Research Expansion', collaborated with the Korea Institute of Radiological and Medical Sciences. In addition, the ARTI is in the progress of establishing cyclotron integrated complex as a core research facility, using a proton beam to produce radioisotopes and to support a various research areas. The measurement and evaluation of the irradiation dose, and irradiation supporting technology of the Good Irradiation Practice(GIP) are essential in various researching areas. One thing to remember is that the publicity

  13. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration

  14. Kinetics of bacterial potentiometric titrations : the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions

    OpenAIRE

    Kapetas, Leon; Ngwenya, Bryne T.; MacDonald, Alan M.; Elphick, Stephen C.

    2011-01-01

    Several recent studies have made use of continuous acid–base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titr...

  15. Online Automatic Titration of Chromic Acid in Chromium Plating Solutions and Phosphoric and Sulfuric Acids in Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1991-01-01

    .... The analytical chemistry literature lacks an adequate online automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric...

  16. Linear titration plot for the determination of boron in the primary coolant of a pressurized water reactor

    International Nuclear Information System (INIS)

    Midgley, D.; Gatford, C.

    1992-01-01

    A linear titration plot method has been devised for the determination of boron as boric acid in partly neutralized solution, such as occurs in the primary coolant of pressurized water reactors. The total boron and the alkali in the sample are determined simultaneously. Although it is not essential to add mannitol in this method, it is more accurate when the solution is saturated with mannitol. Comparisons are made with other modes of titration: Gran plots, first and second differential potentiometric titrations and indicator titrations. None of these gives the total boron directly in partly neutralized solutions. (author)

  17. Laguna Verde simulator: A new TRAC-RT based application

    International Nuclear Information System (INIS)

    Munoz Cases, J.J.; Tanarro Onrubia, A.

    2006-01-01

    In a partnership with GSE Systems, TECNATOM is developing a full scope training simulator for Laguna Verde Unit 2 (LV2). The simulator design is based upon the current 'state-of-the art technology' regarding the simulation platform, instructor station, visualization tools, advanced thermalhydraulics and neutronics models, I/O systems and automated model building technology. When completed, LV2 simulator will achieve a remarkable level of modeling fidelity by using TECNATOM's TRAC-RT advanced thermalhydraulic code for the reactor coolant and main steam systems, and NEMO neutronic model for the reactor core calculations. These models have been utilized up to date for the development or upgrading of nine NPP simulators in Spain and abroad, with more than 8000 hours of training sessions, and have developed an excellent reputation for its robustness and high fidelity. (author)

  18. Durability of resin-dentin bonds.

    Science.gov (United States)

    Shono, Y; Terashita, M; Shimada, J; Kozono, Y; Carvalho, R M; Russell, C M; Pashley, D H

    1999-01-01

    The purpose of this study was to determine if the durability of resin-dentin bonds could be evaluated more quickly if the bond specimen was divided into 1 x 1 x 8 mm beams incubated at 37 degrees C for a 90-day period. Extracted human third molars were prepared for bonding by removing the occlusal surface near the dento-enamel junction (superficial dentin group) or near the pulp (deep dentin group). The teeth were bonded either with MacBond, One Step or Clearfil Liner Bond 2, and then builtup to form a flat resin composite crown. After 24 hours in water, each buildup was vertically divided into slabs 1 mm thick, the top half of which was resin, with the bottom half as dentin. Each slab was then vertically sectioned at 1-mm increments to create 1 x 1 x 8-mm beams of resin-bonded dentin. They were incubated for 1 day or 90 days at 37 degrees C, followed by measurement of the tensile bond strengths. The results were analyzed by the Least-Squares Means method at the 95% confidence level. MacBond gave the highest (p durability of resin-dentin bonds.

  19. Processing of exhausted resins for Trino NPP,

    International Nuclear Information System (INIS)

    Benvenuto, F.; Bitetti, G.; Maggini, F.; Scarsi, G.

    2009-01-01

    Decomposition of organic compounds contained in the spent ion exchange resins is considered effective in reducing the waste volume. A system using the wet-oxidation process has been studied for the treatment of the spent resins stored at Trino Nuclear Power Plant owned by SOGIN. Compared with various processes for treating sludge and resin, the wet-oxidation system is rather simple and the process conditions are mild. Not contaminated ion exchange resin samples similar to those ones used in Trino NPP were processed by wet-oxidation and appropriate decomposition of the organic compounds was verified. After decomposition the residue can be solidified with cement for final disposal. When compared with direct solidification without decomposition, the number of waste packages can be significantly reduced. Additional measures for conditioning secondary waste products have also been studied, and their applicability to the Trino Nuclear Power Plant was verified. Some of conditions studied were specific to the Trino Nuclear Power Plant, but it is expected that the system will provide an effective solution for resin treatment at other Italian NPPs. (authors)

  20. Ponderosa pine resin defenses and growth: metrics matter.

    Science.gov (United States)

    Hood, Sharon; Sala, Anna

    2015-11-01

    Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow

  1. Potentiometric Measurement of Transition Ranges and Titration Errors for Acid/Base Indicators

    Science.gov (United States)

    Flowers, Paul A.

    1997-07-01

    Sophomore analytical chemistry courses typically devote a substantial amount of lecture time to acid/base equilibrium theory, and usually include at least one laboratory project employing potentiometric titrations. In an effort to provide students a laboratory experience that more directly supports their classroom discussions on this important topic, an experiment involving potentiometric measurement of transition ranges and titration errors for common acid/base indicators has been developed. The pH and visually-assessed color of a millimolar strong acid/base system are monitored as a function of added titrant volume, and the resultant data plotted to permit determination of the indicator's transition range and associated titration error. Student response is typically quite positive, and the measured quantities correlate reasonably well to literature values.

  2. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  3. Comparing the Titrations of Mixed-Acid Solutions Using Dropwise and Constant-Flow Techniques

    Science.gov (United States)

    Charlesworth, Paul; Seguin, Matthew J.; Chesney, David J.

    2003-11-01

    A mixed-acid solution containing hydrochloric and phosphoric acids was used to determine the error associated with performing a real-time titration. The results were compared against those obtained by performing the titration in a more traditional dropwise addition of titrant near the equivalence points. It was found that the real-time techniques resulted in significantly decreased analysis times while maintaining a low experimental error. The constant-flow techniques were implemented into two different levels of chemistry. It was found that students could successfully utilize the modified experiments. Problems associated with the techniques, major sources of error, and their solutions are discussed. In both cases, the use of the constant-flow setup has increased student recollection of key concepts, such as pKa determination, proper indicator choice, and recognizing the shape of specific titration curves by increasing student interest in the experiment.

  4. Titration of intravenous synthetic oxytocin post vaginal birth following induction or augmentation.

    Science.gov (United States)

    Lewis, Lucy; Hauck, Yvonne L; Pemberton, Alissa; Crichton, Caroline; Conwell, Marion

    2016-10-01

    Evidence exists for titration of intravenous oxytocin during induction and augmentation, whereas no evidence was identified for titration of intravenous oxytocin following vaginal birth, where management excluded oxytocin for postpartum haemorrhage (PPH). This retrospective cohort study explored this issue through patient case notes and computerised perinatal data. Analysis included 335 women comparing induction (n = 226, 67%) to augmentation (n = 109, 33%). The two groups differed in terms of: parity; oxytocin dosage; length of time on intravenous oxytocin; and the length of first and second stage labour. They had similar rates of PPH and titration of intravenous oxytocin following birth was rarely recorded. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Potentiometric titration of Co(II) in presence of Co(III).

    Science.gov (United States)

    Norkus, E

    1998-12-01

    A potentiometric titration for cobalt(II) determination in the presence of Co(III) based on the oxidation of Co(II) with Na(2)CrO(4) in ethylenediamine medium and back-titration of the oxidant excess with (NH(4))(2)Fe(SO(4))(2) in acid medium is described. The titration is monitored with a Pt indicator electrode and carried out until the greatest jump of potential from one drop of titrant appears. A RSD smaller than 1.5% has been obtained for 50-300 mumol Co(II). The method proposed was applied in the analysis of a new type electroless copper plating solutions containing Co(II)-ethylenediamine complex compounds as reducing agents. Cu(II), Co(III) and Cr(III) do not interfere in the determination of Co(II).

  6. Thermometric titration of a free acid and of uranyl in spent fuel element solutions

    International Nuclear Information System (INIS)

    Zamek, M.; Strafelda, F.

    1975-01-01

    A method was elaborated of determining nitric acid in the presence of uranyl nitrate in both aqueous and non-aqueous solutions using a pyridine aqueous solution as a titration agent, and of determining excess uranyl after a hydrogen peroxide addition by a further titration using the same agent. Even a hundred-fold excess of magnesium did not disturb the titration. The method is used in operating solution analyses in the extraction fuel reprocessing in the presence of a small amount of plutonium and of fission products. The reproducibility and accuracy of the method varied in the order of tens to units per cent depending on the concentration of components to be determined. The procedure is applicable for test volumes ranging between 0.1 and 10 ml in concentrations of 1 to 10 -3 M. (author)

  7. [Research on determination of chemical purity of andrographolide by coulometric titration method].

    Science.gov (United States)

    Yang, Ning; Yang, Dezhi; Xu, Lishen; Lv, Yang

    2010-04-01

    The determination of chemical purity of andrographolide by coulometric titration method is studied in this paper. The coulometric titration was carried out in a mixture composed of 4 mol x L(-1) hydrochloric acid and 1 mol x L(-1) potassium bromide solution and 1 mol x L(-1) potassium nitrate solution (1:1). Bromine is electrogenerated at the anode and reacts with the andrographolide. The number of electrons involved in the eleatrode reaction is 2. Purity of andrographolide is 99.76% compared with 99.77% utilizing area normalization method by HPLC. The RSD are 0.33% and 0.02% respectively. The results from two methods are consistent, so the determination of chemical purity of andrographolide by coulometric titration method is scientific and feasible. The method is rapid, simple, convenient, sensitive and accurate. The reference material is not essential in the method. The method is suitable for determination of chemical purity of andrographolide.

  8. Potentiometric titrations of para and nitro substituted aromatic acids and their mixtures in methylethyl ketone

    International Nuclear Information System (INIS)

    Ozeroglu, C.; Karahan, M.

    2011-01-01

    In this study, it was the purpose to examine the potentiometric titrations of para and nitro substituted aromatic acids in methylethyl ketone (MEK) as a non-aqueous solvent. Good analytical results were obtained in determining the amount of each acid and the amounts of acids in their ternary mixtures by using 0.0964 N tetrabuthylammoniumhydroxyde (TBAH) as a standard titrant. Methylethyl ketone (MEK) which is a good solvent for many organic compounds and has a convenient liquid range of -86 to 80 deg. C was used for titration of the para and nitro substituted aromatic acids. A linear relationship has been found between pKa values of the para and nitro substituted aromatic acids in water and the half neutralization potential (HNP) values determined by potentiometric titration curves of the same acids in MEK. (author)

  9. Oxygen titration in sodium. The mercury method and its use for very low values

    International Nuclear Information System (INIS)

    Champeix, L.; Darras, R.; Duflo, J.

    1958-01-01

    The mercury method for the oxygen titration in sodium has now been known for ten years and is probably the more frequently used. In this text, precision are given to what extent it is valuable when used in microanalysis. Details are given on the apparatus, its manipulation and its calibration. After testing, we have decided to use flame spectroscopy to titrate the sodium hydroxide formed. Discussions are exposed on the errors due to the presence of sodium chloride and calcium. Results are examined from the point of view of their reproducibility and accuracy. If great care is taken, this method allows oxygen titration in sodium even for values below 10 ppm with satisfactory precision. (author) [fr

  10. High frequency titration in non-aqueous solvents. Application to HF and UF6

    International Nuclear Information System (INIS)

    Neveu, Claude

    1965-01-01

    In this research thesis, the author first presents the main theoretical notions regarding high frequency titration, notably by studying characteristic curves, i.e. the titration meter indication with respect to conductibility. He reports the use of this method for the study of various reactions in non-aqueous medium: reaction of AlCl 3 with pyridine in acetonitrile, of AlCl 3 with HCl in tetrachloroethane and in nitromethane. He also reports the attempt of application of this method to the titration of HF in presence of UF 6 in CCl 4 as solvent, or by using F acceptors like BF 3 , PF 5 or ClF 3 as reactants [fr

  11. Clinical Outcomes of Continuation of Metformin Titration Instructions with Electronic Prescribing.

    Science.gov (United States)

    Delate, Thomas; Rader, Nathan; Rawlings, Julia E; Smith, Karen; Herner, Sheryl J

    2015-06-01

    Anecdotal evidence suggests that metformin titration instructions are not being updated and refill requests are approved without modification of the titration instructions such that the titration instructions is continued for patients newly initiated on metformin. This was a retrospective cohort analysis of adult patients who received newly initiated metformin pharmacotherapy. Patients were followed from their initial metformin purchase through two subsequent metformin refill purchases. Outcomes, including the 3-year incidence rate of patients with at least one set of continued titration instructions and proportions of patients with at least one gastrointestinal adverse effect (AE) and those with an elevated glucose measurement at follow-up, were assessed during the time period between patients' second and third metformin purchases. Analyses were performed comparing the exposure (i.e., patients with continued instructions) group to the control (i.e., patients without continued instructions) group. The exposure group had a higher mean age and chronic disease score but lower metformin starting dose than the control group (all p titration instructions was 60.3 % (95 % CI 58.3-62.3). Gastrointestinal AEs were rare with equivalent proportions of patients in each group experiencing an event (p > 0.05). Control patients (48.7 % of patients with a measurement) were more likely to have had poorly controlled glucose than exposure patients (35.7 % of patients with a measurement) (p titration instructions for patients newly initiated on metformin was observed; however, such continuation did not negatively affect clinical outcomes.

  12. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  13. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  14. Comparison of Three-Dimensional (3D) Conformal Proton Radiotherapy (RT), 3D Conformal Photon RT, and Intensity-Modulated RT for Retroperitoneal and Intra-Abdominal Sarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Swanson, Erika L. [Department of Radiation Oncology, University of Florida, Gainesville, Florida (United States); Indelicato, Daniel J., E-mail: dindelicato@floridaproton.org [Department of Radiation Oncology, University of Florida, Gainesville, Florida (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Louis, Debbie; Flampouri, Stella; Li, Zuofeng [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States); Morris, Christopher G.; Paryani, Nitesh [Department of Radiation Oncology, University of Florida, Gainesville, Florida (United States); Slopsema, Roelf [University of Florida Proton Therapy Institute, Jacksonville, Florida (United States)

    2012-08-01

    Purpose: To compare three-dimensional conformal proton radiotherapy (3DCPT), intensity-modulated photon radiotherapy (IMRT), and 3D conformal photon radiotherapy (3DCRT) to predict the optimal RT technique for retroperitoneal sarcomas. Methods and Materials: 3DCRT, IMRT, and 3DCPT plans were created for treating eight patients with retroperitoneal or intra-abdominal sarcomas. The clinical target volume (CTV) included the gross tumor plus a 2-cm margin, limited by bone and intact fascial planes. For photon plans, the planning target volume (PTV) included a uniform expansion of 5 mm. For the proton plans, the PTV was nonuniform and beam-specific. The prescription dose was 50.4 Gy/Cobalt gray equivalent CGE. Plans were normalized so that >95% of the CTV received 100% of the dose. Results: The CTV was covered adequately by all techniques. The median conformity index was 0.69 for 3DCPT, 0.75 for IMRT, and 0.51 for 3DCRT. The median inhomogeneity coefficient was 0.062 for 3DCPT, 0.066 for IMRT, and 0.073 for 3DCRT. The bowel median volume receiving 15 Gy (V15) was 16.4% for 3DCPT, 52.2% for IMRT, and 66.1% for 3DCRT. The bowel median V45 was 6.3% for 3DCPT, 4.7% for IMRT, and 15.6% for 3DCRT. The median ipsilateral mean kidney dose was 22.5 CGE for 3DCPT, 34.1 Gy for IMRT, and 37.8 Gy for 3DCRT. The median contralateral mean kidney dose was 0 CGE for 3DCPT, 6.4 Gy for IMRT, and 11 Gy for 3DCRT. The median contralateral kidney V5 was 0% for 3DCPT, 49.9% for IMRT, and 99.7% for 3DCRT. Regardless of technique, the median mean liver dose was <30 Gy, and the median cord V50 was 0%. The median integral dose was 126 J for 3DCPT, 400 J for IMRT, and 432 J for 3DCRT. Conclusions: IMRT and 3DCPT result in plans that are more conformal and homogenous than 3DCRT. Based on Quantitative Analysis of Normal Tissue Effects in Clinic benchmarks, the dosimetric advantage of proton therapy may be less gastrointestinal and genitourinary toxicity.

  15. Microshear bond strength of composite resins to enamel and porcelain substrates utilizing unfilled versus filled resins.

    Science.gov (United States)

    Najafi-Abrandabadi, Ahmad; Najafi-Abrandabadi, Siamak; Ghasemi, Amir; Kotick, Philip G

    2014-11-01

    Failures such as marginal discoloration and composite chipping are still the problems of tooth-colored restorations on the substrate of enamel and porcelain, which some of these problems are consequently as a result of failures in the bonding layer. Using filled resin has been recently introduced to increase the bond strength of this layer. The aim of this study was to compare the microshear bond strength (μ-SBS) of composite resins to enamel incubated in periods of 24 h and 9 months and porcelain with unfilled resin and flowable composites (filled resin). In this in vitro study, two groups of 75 enamel samples with different storage times (24 h and 9 months) and a group of 75 porcelain samples were used. They were divided into 5 experimental groups of 15 samples in each. Composite cylinders in tygon tubes were bonded on the surface of acid-etched enamel and pretreated porcelain. Wave, Wave MV, Wave HV, Grandioflow and Margin Bond were used as bonding agents. The μ-SBS was measured at the speed of 1.0 mm/min. The bond strengths were analyzed with one-way analysis of variance (ANOVA) test followed by Tukey test. P composites (filled resins) can be used instead of unfilled resins in bonding composite resins to enamel and porcelain substrates.

  16. Comparative study of resin sealant and resin modified glass ionomer as pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Shirin Malek

    2017-02-01

    Full Text Available The purpose of the present study was to compare the marginal integrity of resin modified glass ionomer cement with that of resin sealant, in vitro. Forty artificial pit and fissure cavities were prepared in occlusal surface of extracted premolar teeth by using ¼ round carbide bur. Cavities were condensed with artificial organic debris followed by cleaning with prophylaxis pumice brush and paste and then separated into two treatment groups. In Group A, 15 fissure cavities were sealed by resin sealant and in Group B, 15 fissure cavities were sealed by resin modified glass ionomer sealant. These specimens were subjected to thermo-cycling followed by dye penetration test. The remaining 5 cavities from each group were analyzed for debris score by the SEM. The results of the microleakage test showed that the efficacy of preventing microleakage of samples sealed by resin modified glass ionomer sealant was higher than the samples sealed by resin sealant. However, no significant differences were found. It can be concluded that use of resin modified glass ionomer sealant is a good alternative for sealing pits and fissures.

  17. Aging in CTBN modified epoxy resin stocks

    International Nuclear Information System (INIS)

    Creed, K.E. Jr.

    1979-01-01

    The cause of degradation in the glass transition temperature (T/sub G/) of a partially crystallized polymer was investigated. Sample epoxy resin filled capacitors were cured at 90 0 C for 24 hours, then stored at room atmospheric conditions. These showed typical degradation in T/sub G/ after storage for one month. One set of epoxy resin castings was stored at room atmosphere and another set was stored in a dry box at 0% relative humidity and 27 0 C. The samples at room atmospheric conditions showed typical degradation in T/sub G/, while the T/sub G/ for those stored in the dry box increased. Further tests were then made on epoxy resin castings at various curing temperatures and times at both room atmosphere and 0% humidity. Resulting data indicated that absorption of moisture during storage was the predominant cause of T/sub G/ degradation, with stress relaxation another, though smaller, contributing factor

  18. Resin injection in clays with high plasticity

    Science.gov (United States)

    Nowamooz, Hossein

    2016-11-01

    Regarding the injection process of polyurethane resins in clays with high plasticity, this paper presents the experimental results of the pressuremeter and cone penetration tests before and after injection. A very important increase in pressure limit or in soil resistance can be observed for all the studied depths close to the injection points. An analytical analysis for cylindrical pore cavity expansion in cohesive frictional soils obeying the Mohr-Coulomb criterion was then used to reproduce the pressuremeter tests before and after injection. The model parameters were calibrated by maintaining constant the elasticity parameters as well as the friction angel before and after injection. A significant increase in cohesion was observed because of soil densification after resin expansion. The estimated undrained cohesions, derived from the parameters of the Mohr-Coulomb criterion, were also compared with the cone penetration tests. Globally, the model predictions show the efficiency of resin injection in clay soils with high plasticity.

  19. Restoration of traumatized teeth with resin composites

    DEFF Research Database (Denmark)

    Pallesen, Ulla; van Dijken, Jan WV

    2018-01-01

    For a long time, the primary choice for initial restoration of a crown-fractured front tooth has been resin composite material. The restoration can in most cases be performed immediately after injury if there is no sign of periodontal injury. The method’s adhesive character is conservative to tooth......-structure and with minimal risk of pulpal complication. In addition, it offers an aesthetic solution to the patient immediately after an injury, which may bring a little comfort in a sad situation. The resin composite build-up is often changed or repaired a couple of times, before the tooth is restored with a porcelain...... present an aesthetic problem due to exposure of un-aesthetic crown-margins. The invasive permanent crown restorations are therefore often not suc-cessful on a long-term scale. On the other hand, a conservative direct restoration of an extensively fractured incisor crown with resin composite may...

  20. Investigations of toughening mechanisms of epoxy resins

    Science.gov (United States)

    Koenig, T.

    1986-01-01

    Composite material technology was applied to the solid rocket booster by the development of a carbon filament-epoxy resin case which yields a net increase of 4000 lbs. in payload in the shuttle. The question of reusability of the new composite tanks has not yet been answered and will depend on the toughness of the matrix resin. The present study was aimed at providing conditions whereby test specimens of the epoxy resin (EPON/85) and curing agents of systematically varied structures could be produced in a controlled manner. Three sets of conditions were found that might allow the isolation of the structural effects on toughness from the cure effects. The kinetic methods leading to the determination of these conditions are described.

  1. Effect of proximal box elevation with resin composite on marginal quality of resin composite inlays in vitro.

    Science.gov (United States)

    Roggendorf, Matthias J; Krämer, Norbert; Dippold, Christoph; Vosen, Vera E; Naumann, Michael; Jablonski-Momeni, Anahita; Frankenberger, Roland

    2012-12-01

    To evaluate marginal quality and resin-resin transition of lab made resin composite inlays in deep proximal cavities with and without 3 mm proximal box elevation (PBE) using resin composites before and after thermo-mechanical loading (TML). MOD cavities with one proximal box beneath the cementoenamel junction were prepared in 40 extracted human third molars. Proximal boxes ending in dentine were elevated 3 mm with different resin composites (G-Cem, Maxcem Elite as self-adhesive resin cements and Clearfil Majesty Posterior as restorative resin composite in one or three layers bonded with AdheSE), or left untreated. Clearfil Majesty Posterior inlays were luted with Syntac and Variolink II (n = 8). Marginal quality as well as the PBE-composite inlay interface was analyzed under an SEM using epoxy resin replicas before and after thermomechanical loading (100,000 × 50 N and 2500 thermocylces between +5 °C and +55 °C). Bonding resin composite inlays directly to dentine showed similar amounts of gap-free margins in dentine compared to PBE applied in three consecutive layers (p > 0.05). The groups with self-adhesive resin cements for PBE exhibited significantly more gaps in dentine (p < 0.05). With layered resin composite, PBE is effective in indirect resin composite bonding to deep proximal boxes. Self-adhesive resin cements are not suitable for this indication. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. 76 FR 8774 - Granular Polytetrafluoroethylene Resin From Japan

    Science.gov (United States)

    2011-02-15

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Granular Polytetrafluoroethylene Resin From Japan AGENCY: United States International Trade... polytetrafluoroethylene resin from Japan would be likely to lead to continuation or recurrence of material injury. On...

  3. Composite resin fillings and inlays: An 11-year evaluation

    DEFF Research Database (Denmark)

    Pallesen, U.; Qvist, V.

    2003-01-01

    Clinical trial, composite resin, direct restorations, indirect restorations, long-term behaviour, posterior teeth......Clinical trial, composite resin, direct restorations, indirect restorations, long-term behaviour, posterior teeth...

  4. Development of 3-methoxy-4-benzyloxybenzyl alcohol (MBBA) resin ...

    Indian Academy of Sciences (India)

    step sequence under microwave irradiation involving the reaction of commercially available Merrifield resin with vanillin, followed by reduction with sodium borohydride. MBBA resin was treated with bromides in the presence of sodium hydride to ...

  5. Fluorinated Alkyl Ether Epoxy Resin Compositions and Applications Thereof

    Science.gov (United States)

    Wohl, Christopher J. (Inventor); Connell, John W. (Inventor); Smith, Joseph G. (Inventor); Siochi, Emilie J. (Inventor); Gardner, John M. (Inventor); Palmieri, Frank M. (Inventor)

    2017-01-01

    Epoxy resin compositions prepared using amino terminated fluoro alkyl ethers. The epoxy resin compositions exhibit low surface adhesion properties making them useful as coatings, paints, moldings, adhesives, and fiber reinforced composites.

  6. Determination of acid–base properties of HCl acid activated palygorskite by Potentiometrie titration

    OpenAIRE

    N. FriniSrasra; E.Srasra

    2008-01-01

    The surface acidity of raw and acid activated palygorskite clay were studied by acid-base potentiometric titration. The Gran plot method was applied for the hydroxide titration and the total surface site (Hs) and the average number of protons reacted per surface site (Z) of palygorskite samples at a given ionic strength were calculated. Acid treatment increases the clay acidity and modifies its surface charge. The point of zero charge value, determined by the common crossing point of Z vs pH ...

  7. Lacosamide and sodium channel-blocking antiepileptic drug cross-titration against levetiracetam background therapy.

    Science.gov (United States)

    Baulac, M; Byrnes, W; Williams, P; Borghs, S; Webster, E; De Backer, M; Dedeken, P

    2017-04-01

    To assess prospectively the effectiveness of lacosamide (LCM) added to levetiracetam (LEV) after down-titration of a concomitant sodium channel blocker (SCB) among patients with focal epilepsy not adequately controlled on LEV and SCB. In this open-label trial, LCM was initiated at 100 mg/day and up-titrated to 200-600 mg/day over 9 weeks; SCB down-titration started when LCM dose reached 200 mg/day. Patients remained on stable LCM/LEV doses for 12 weeks' maintenance (21-week treatment period). The primary outcome was retention rate on LCM. Due to recruitment challenges, fewer than the planned 300 patients participated in the trial, resulting in the trial being underpowered. Overall, 120 patients (mean age 39.7 years) started and 93 completed the trial. The most frequently used SCBs were lamotrigine (39.2%), carbamazepine (30.8%) and oxcarbazepine (27.5%). Eighty-four patients adhered to protocol and discontinued their SCB after cross-titration, but there was insufficient evidence for 36 patients. Retention rate was 73.3% (88/120) for all patients and 83.3% (70/84) for those with evidence of SCB discontinuation. Seizure freedom for patients completing maintenance was 14.0% (13/93). Discontinuation due to adverse events (6.7%) and lack of efficacy (3.3%) occurred primarily during cross-titration. Most frequently reported adverse events during treatment were dizziness (23.3%), headache (15.0%) and fatigue (8.3%). In patients with uncontrolled seizures on LEV/SCB, the LCM/LEV combination appeared to be effective and well tolerated. A cross-titration schedule-flexible LCM up-titration, concomitant SCB down-titration and stable background LEV-could present a feasible and practical approach to initiating LCM while minimizing pharmacodynamic interactions with a SCB. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Selective two-step titration of thorium by sulfate displacement of the diethylenetriaminepentaacetic acid complex

    International Nuclear Information System (INIS)

    Kiefer, P.

    1980-07-01

    Thorium and other metals are complexed with excess diethylenetriaminepentaacetic acid (DTPA) at pH 1.4, the excess DTPA is titrated with Bi(III) to a xylenol orange end point, sulfate is added to complex Th(IV), and the displaced DTPA again is titrated with Bi(III). Of 61 metal ions and nonmetal anions tested, only Ga(III), Sc(III), tungstate, citrate, oxalate, and thiosulfate interfere seriously. Lesser interferences are In(III), Zr(IV), V(IV), and permanganate. The standard deviation is 2 μg for 56 to 840 μg Th

  9. Higher Order Inclusion Complexes and Secondary Interactions Studied by Global Analysis of Calorimetric Titrations

    DEFF Research Database (Denmark)

    Schönbeck, Jens Christian Sidney; Holm, René; Westh, Peter

    2012-01-01

    This paper investigates the use of isothermal titration calorimetry (ITC) as a tool for studying molecular systems in which weaker secondary interactions are present in addition to a dominant primary interaction. Such systems are challenging since the signal pertaining to the stronger primary......). The results are validated by a 13C NMR titration and negative controls with a bile salt with no secondary binding site (glycocholate) (K = 2.96 ± 0.01 × 103 M–1). The method proved useful for detailed analysis of ITC data and may strengthen its use as a tool for studying molecular systems by advanced binding...

  10. Complexometric consequent titration of bismuth-titanium mixtures in the μg-region

    International Nuclear Information System (INIS)

    Schaefer, H.

    1975-01-01

    A quantitative method is described for the determination of microquantities of bismuth and titanium. Both metals are determined complexometrically with EDTA and potentiometric equivalence point indication using a Cu-ion sensitive electrode in a consequent titration. The analysis is conducted as back-titration with standard Cu-solution. The relative error of the determination is 0.8% for bismuth (50-100 μg) and for titanium (10-30 μg) at 1.0%. Under the chosen conditions, it is possible to determine as little as 15 μg bismuth and 5 μg titanium by means of this procedure. (author)

  11. Comparison of Titration ICP and XRF Spectrometry Methods in Determination of Cerium in Lens Polishing Powder

    International Nuclear Information System (INIS)

    Ninlaphruk, Sumalee; Pichestapong, Pipat; Mungpayabal, Harinate; Jiyavaranant, Thitima; Srisukho, Supapan; Chaisai, Prapassurn

    2004-10-01

    Three analytical methods in determination of cerium in cerium oxide separated from monazite ore for producing lens polishing powder were compared. These methods are titration ICP and XRF spectrometry techniques. The cerium oxide sample with estimated 45% cerium content needed to be digested and converted into solution before the analysis. The analytical results shown significantly no difference between each method. However, the titration method was found to be more convenient and suitable for quality control in the production of cerium oxide as it does not require standard cerium and the complicated analytical instruments

  12. Determination of fluoride ions in water by condutometric titration with lanthanum nitrates

    International Nuclear Information System (INIS)

    Alves, J.C.

    1986-01-01

    An alternative method for determining fluoride ions in drinking water by condutometric titration using La(NO 3 ) 3 as titrant is presented. The method is based on previous separation of fluoride from sample by distillation at 135 0 C. The pH of the distillated is adjusted between 5,5 - 6,0; ethanol is adicioned in 50% titrating the resultant solution with La(NO 3 ) 3 . In these conditions, fluoride ions are determined with accuracy respectively, 5% and 4%. Natural samples of drinking water were analysed by this method and by the ion selective method, with agreement among the results. (author) [pt

  13. Biphenyl liquid crystalline epoxy resin as a low-shrinkage resin-based dental restorative nanocomposite.

    Science.gov (United States)

    Hsu, Sheng-Hao; Chen, Rung-Shu; Chang, Yuan-Ling; Chen, Min-Huey; Cheng, Kuo-Chung; Su, Wei-Fang

    2012-11-01

    Low-shrinkage resin-based photocurable liquid crystalline epoxy nanocomposite has been investigated with regard to its application as a dental restoration material. The nanocomposite consists of an organic matrix and an inorganic reinforcing filler. The organic matrix is made of liquid crystalline biphenyl epoxy resin (BP), an epoxy resin consisting of cyclohexylmethyl-3,4-epoxycyclohexanecarboxylate (ECH), the photoinitiator 4-octylphenyl phenyliodonium hexafluoroantimonate and the photosensitizer champhorquinone. The inorganic filler is silica nanoparticles (∼70-100 nm). The nanoparticles were modified by an epoxy silane of γ-glycidoxypropyltrimethoxysilane to be compatible with the organic matrix and to chemically bond with the organic matrix after photo curing. By incorporating the BP liquid crystalline (LC) epoxy resin into conventional ECH epoxy resin, the nanocomposite has improved hardness, flexural modulus, water absorption and coefficient of thermal expansion. Although the incorporation of silica filler may dilute the reinforcing effect of crystalline BP, a high silica filler content (∼42 vol.%) was found to increase the physical and chemical properties of the nanocomposite due to the formation of unique microstructures. The microstructure of nanoparticle embedded layers was observed in the nanocomposite using scanning and transmission electron microscopy. This unique microstructure indicates that the crystalline BP and nanoparticles support each other and result in outstanding mechanical properties. The crystalline BP in the LC epoxy resin-based nanocomposite was partially melted during exothermic photopolymerization, and the resin expanded via an order-to-disorder transition. Thus, the post-gelation shrinkage of the LC epoxy resin-based nanocomposite is greatly reduced, ∼50.6% less than in commercialized methacrylate resin-based composites. This LC epoxy nanocomposite demonstrates good physical and chemical properties and good biocompatibility

  14. The influence of resin flexural modulus on the magnitude of ceramic strengthening.

    LENUS (Irish Health Repository)

    Fleming, Garry J P

    2012-07-01

    The aim was to determine the magnitude of ceramic resin-strengthening with resin-based materials with varying flexural moduli using a regression technique to assess the theoretical strengthening at a \\'zero\\' resin-coating thickness. The hypothesis tested was that experimentally, increasing resin flexural modulus results in increased resin-strengthening observed at a theoretical \\'zero\\' resin-coating thickness.

  15. Performances and improvement of copper-hydrazine complexation deoxidising resin

    International Nuclear Information System (INIS)

    Liu Fenfen; Zhang Hao; Sun Haijun; Liu Xiaojie

    2012-01-01

    Copper-hydrazine complexation deoxidising resin is tested to examine its performances including effluent water quality and capacity of deoxidisation. By the means of changing the resin type and regeneration, the deoxidising capacity of the resin can be improved to 13 times more than before. At the same time, physical performances of the resin are also greatly improved while maintaining its velocity of deoxidisation and effluent quality. (authors)

  16. Recovery of tretrachloroaurate through ion exchange with Dowex 11 resin

    International Nuclear Information System (INIS)

    Alguacil, F.J.

    1998-01-01

    The recovery of the tretrachloroaurate complex by the anionic ion exchange resin Dowex 11 has been studied. The kinetics of gold adsorption were dependent of both gold and resin concentrations and temperature. The adsorption isotherm can be described by the expression Q=kC''n. The loaded resin could be eluted by an acidic thiourea solution at 20 degree centigree. After several adsorption-elution cycles there is not any apparent loss in the adsorption properties of the resin. (Author) 6 refs

  17. Interacting Blends of Novel Unsaturated Polyester Amide Resin with Styrene

    OpenAIRE

    Patel, Hasmukh S.; Panchal, Kumar K.

    2004-01-01

    Novel unsaturated poly (ester-amide) resins (UPEAs) were prepared by the reaction between an epoxy resin, namely diglycidyl ether of bisphenol–A (DGEBA) and unsaturated aliphatic bisamic acids using a base catalyst. These UPEAs were then blended with a vinyl monomer namely, Styrene (STY.) to produce a homogeneous resin syrup. The curing of these UPEAs-STY. resin blends was carried out by using benzoyl peroxide (BPO) as a catalyst and was monitored by using a differential scanning calorimeter ...

  18. Gamma-irradiation on cured glycidyl amino-epoxy resin

    International Nuclear Information System (INIS)

    Yang, Ting; Wei, Chengsha; Liu, Hewen

    2010-01-01

    ITER is an international project to design and build an experimental fusion reactor based on the superconductive 'tokamak' concept. Amounts of epoxy resin are used in the superconductive tokamak device as impregnant resins, insulation breaks, etc. Resistance to ionizing radiation is a demanding performance of those epoxy resins. In this work, we study the effects of γ-irradiation on the mechanical properties and chemical structures of glycidyl amino-epoxy resins

  19. Synthesis of a boron modified phenolic resin

    Directory of Open Access Journals (Sweden)

    Aparecida M. Kawamoto

    2010-08-01

    Full Text Available Phenolic resin has long been used as matrix for composites mainly because of its flame retardant behavior and high char yield after pyrolysis, which results in a self supporting structure. The addition of ceramic powders, such as SiC and B4C, as fillers to the phenolic resin, results in better thermo-oxidative stability, but as drawbacks, it has poor homogeneity, adhesion and processing difficulties during molding of the composites. The addition of single elements, such as boron, silicon and phosphorus in the main backbone of the thermo-set resin is a new strategy to obtain special high performance resins, which results in higher mechanical properties, avoiding the drawbacks of simply adding fillers, which results in enhanced thermo-oxidative stability compared to conventional phenol-formaldehyde resins. Therefore, the product can have several applications, including the use as ablative thermal protection for thermo-structural composites. This work describes the preparation of a boron-modified phenolic resin (BPR using salicyl alcohol and boric acid. The reaction was performed in refluxing toluene for a period of four hours, which produced a very high viscosity amber resin in 90% yield.The final structure of the compound, the boric acid double, substituted at the hydroxyl group of the aromatic ring, was determined with the help of the Infrared Spectroscopy, ¹H-NMR, TGA-DSC and boron elemental analysis. The absorption band of the group B-O at 1349 cm ˉ¹ can be visualized at the FT-IR spectrum. ¹H-NMR spectra showed peaks at 4.97-5.04 ppm and 3.60-3.90 ppm assigned to belong to CH2OH groups from the alcohol. The elemental analysis was also performed for boron determination.The product has also been tested in carbon and silicon fibers composite for the use in thermal structure. The results of the tests showed composites with superior mechanical properties when compared with the conventional phenolic resin.

  20. Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin

    Directory of Open Access Journals (Sweden)

    H. Kimura

    2011-12-01

    Full Text Available Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin were investigated. The cure behavior of benzoxazine with cyanate ester resin was monitored by model reaction using nuclear magnetic resonance (NMR. As a result of the model reaction, the ring opening reaction of benzoxazine ring and thermal self-cyclotrimerization of cyanate ester group occurred, and then the phenolic hydoroxyl group generated by the ring opening reaction of benzoxazine ring co-reacted with cyanate ester group. The properties of the cured thermosetting resin were estimated by mechanical properties, electrical resistivity, water resistance and heat resistance. The cured thermosetting resin from benzoxazine and cyanate ester resin showed good heat resistance, high electrical resistivity and high water resistance, compared with the cured thermosetting resin from benzoxazine and epoxy resin.

  1. Development of amino resin for paint formulation: Copolymerization ...

    African Journals Online (AJOL)

    SERVER

    2007-06-18

    Jun 18, 2007 ... The moisture uptake of the different resin films was determined gravimetrically. Known weights of each of ... as the moisture intake by the resin (Barminas and Osemeahon,. 2006). All determinations were performed ... Therefore during the condensation reactions of methylol urea resins into polymer chains, ...

  2. Facile synthesis of allyl resinate monomer in an aqueous solution ...

    Indian Academy of Sciences (India)

    as oligomer products such as inks and coatings. Com- pared with the oligomer from fossil resources such as acrylic resins and styrene resins, we believe the intro- duction of the resin structure into polymer products can provide specific mechanical properties, such as hardness and flexibility. GC analysis of each component ...

  3. 21 CFR 872.3670 - Resin impression tray material.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin impression tray material. 872.3670 Section...

  4. Evaluation of some anionic exchange resins as potential tablet ...

    African Journals Online (AJOL)

    The effect of resin concentration and compression force on the properties of tablets using the selected resin was investigated. In addition, the disintegrant efficacy of the selected resin in the tablet formulations containing either a basic drug, e.g., dextromethorphan hydrobromide (DMP), or an acidic drug, e.g., diclofenac ...

  5. 21 CFR 173.40 - Molecular sieve resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Molecular sieve resins. 173.40 Section 173.40 Food... Polymer Substances and Polymer Adjuvants for Food Treatment § 173.40 Molecular sieve resins. Molecular sieve resins may be safely used in the processing of food under the following prescribed conditions: (a...

  6. 75 FR 67105 - Granular Polytetrafluoroethylene Resin From Italy and Japan

    Science.gov (United States)

    2010-11-01

    ... COMMISSION Granular Polytetrafluoroethylene Resin From Italy and Japan AGENCY: United States International... granular polytetrafluoroethylene resin from Italy and Japan. SUMMARY: The Commission hereby gives notice... polytetrafluoroethylene resin from Italy and Japan would be likely to lead to continuation or recurrence of material...

  7. Photosensitive filler minimizes internal stresses in epoxy resins

    Science.gov (United States)

    Dillon, J. N.

    1967-01-01

    Photosensitive filler is added to curable epoxy resins to minimize stress from internal shrinkage during curing or polymerization. Cinnamic acid resins and cinnamal ketones may be added in the amount of 1 to 3 percent by weight of the resin mixture.

  8. Color change of composite resins subjected to accelerated artificial aging.

    Science.gov (United States)

    Tornavoi, Denise Cremonezzi; Agnelli, José Augusto Marcondes; Panzeri, Heitor; Dos Reis, Andréa Cândido

    2013-01-01

    The aim of this study was to evaluate the influence of accelerated artificial aging (AAA) on the color change of composite resins used in dentistry. Three composite resins were evaluated: Two microhybrids and one hybrid of higher viscosity, with different amounts and sizes of filler particles, shades C2 and B2. A total of 54 specimens were obtained (18 for each composite resin), made of a Teflon matrix (15 mm in diameter and 2 mm in height). The color measurements were obtained with a Spectrophotometer, (PCB 6807 BYK Gardner) before and after AAA. Data were submitted to the Kolmogorov-Smirnov test (α >0.05), ANOVA and Tukey test (α composite resins with the same shades was analyzed. All composite resins showed unacceptable color changes after AAA (ΔE > 3). Considering the variable ∆E, it was observed that the color tone C2 was already statistically different for the microhybrid composite resin prior to AAA (P composite resins (P composite resin group, before aging the composite resin hybrid of higher viscosity B2 showed the highest color variation rate and microhybrid with zirconium/silica C2 showed the lowest. All composite resins presented unacceptable color changes after 382 h of aging and different composite resins with same hue, presented different colors before being subjected to the aging process (B2 and C2) and after (B2). It was also observed color difference within a group of the same composite resin and same hue.

  9. Development of radiation-curable resin based on natural rubber

    International Nuclear Information System (INIS)

    Dahlan Mohd; Abdul Ghani Harun

    1993-01-01

    A new radiation curable resin based on natural rubber has been developed. The resin was based on the reaction between low molecular weight epoxidised natural rubber and acrylic acid. When formulated with reactive monomers and photoinitiator, it solidified upon irradiation with UV light. The resin may find applications in coating for cellulosic-based substrates and pressure-sensitive adhesive

  10. Resin impregnation of cellulose nanofibril films facilitated by water swelling

    Science.gov (United States)

    Yan Qing; Ronald Sabo; Zhiyong Cai; Yiqiang Wu

    2013-01-01

    Flexible composite films were produced by impregnating aqueous phenol formaldehyde (PF) resin into water-swollen cellulose nanofibril (CNF) films. CNF films were prepared using a pressurized filtration method in combination with freeze drying. The freeze-dried films were swollen with water then impregnated with PF resin by soaking in aqueous resin solutions of varying...

  11. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as articles...

  12. 21 CFR 177.2260 - Filters, resin-bonded.

    Science.gov (United States)

    2010-04-01

    ... a pH above 5.0. (j) Resin-bonded filters conforming with the specifications of paragraph (j) (1) of... bulk quantities of nonalcoholic, aqueous foods having a pH of 5.0 or below. (k) Resin-bonded filters...: List of Substances and Limitations (1) Fibers: Cellulose pulp. Cotton. Nylon. (From nylon resins...

  13. 40 CFR 721.5908 - Modified phenolic resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Modified phenolic resin (generic). 721... Substances § 721.5908 Modified phenolic resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as modified phenolic resin (PMN P...

  14. 40 CFR 721.2673 - Aromatic epoxide resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Aromatic epoxide resin (generic). 721... Substances § 721.2673 Aromatic epoxide resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as aromatic epoxide resin (PMN P...

  15. Treatment of White Spot Lesions with Icon (Resin Infiltration)

    Science.gov (United States)

    2017-03-23

    FROM: 59 MDW/SGVU SUBJECT: Professional Presentation Approval 8 MAR2017 1. Your paper, entitled T reatment of White Spot Lesions with Icon ( Resin ... Resin Infiltration) 6. TITLE OF MATERIAL TO BE PUBLISHED OR PRESENTED: Treatment of White Spot lesions with Icon ( Resin In filtration) 7. FUNDING

  16. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin...

  17. 40 CFR 721.9499 - Modified silicone resin.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Modified silicone resin. 721.9499... Substances § 721.9499 Modified silicone resin. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a modified silicone resin (PMN P-96-1649) is...

  18. 40 CFR 721.4380 - Modified hydrocarbon resin.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Modified hydrocarbon resin. 721.4380... Substances § 721.4380 Modified hydrocarbon resin. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a modified hydrocarbon resin (P-91-1418) is...

  19. 40 CFR 721.5905 - Modified phenolic resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Modified phenolic resin (generic). 721... Substances § 721.5905 Modified phenolic resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a modified phenolic resin (PMN...

  20. 21 CFR 872.3200 - Resin tooth bonding agent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin tooth bonding agent. 872.3200 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3200 Resin tooth bonding agent. (a) Identification. A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted...

  1. 40 CFR 721.5762 - Aromatic aldehyde phenolic resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Aromatic aldehyde phenolic resin... Specific Chemical Substances § 721.5762 Aromatic aldehyde phenolic resin (generic). (a) Chemical substance... aromatic aldehyde phenolic resin (PMN P-01-573) is subject to reporting under this section for the...

  2. 21 CFR 872.3690 - Tooth shade resin material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tooth shade resin material. 872.3690 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3690 Tooth shade resin material. (a) Identification. Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl...

  3. Development of 3-methoxy-4-benzyloxybenzyl alcohol (MBBA) resin ...

    Indian Academy of Sciences (India)

    Administrator

    Abstract. 3-Methoxy-4-benzyloxybenzyl alcohol (MBBA) resin was synthesized by a two-step se- quence under microwave irradiation involving the reaction of commercially available Merrifield resin with vanillin, followed by reduction with sodium borohydride. MBBA resin was treated with bromides in the presence of sodium ...

  4. Color change of composite resins subjected to accelerated artificial aging

    Directory of Open Access Journals (Sweden)

    Denise Cremonezzi Tornavoi

    2013-01-01

    Conclusions: All composite resins presented unacceptable color changes after 382 h of aging and different composite resins with same hue, presented different colors before being subjected to the aging process (B2 and C2 and after (B2. It was also observed color difference within a group of the same composite resin and same hue.

  5. 21 CFR 177.2510 - Polyvinylidene fluoride resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyvinylidene fluoride resins. 177.2510 Section... as Components of Articles Intended for Repeated Use § 177.2510 Polyvinylidene fluoride resins. Polyvinylidene fluoride resins may be safely used as articles or components of articles intended for repeated use...

  6. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a water...

  7. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  8. 76 FR 4936 - Granular Polytetrafluoroethylene Resin From Italy

    Science.gov (United States)

    2011-01-27

    ... Polytetrafluoroethylene Resin From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule... granular polytetrafluoroethylene resin (``granular PTFE resin'') from Italy. DATES: Effective Date: January... from Italy and Japan (75 FR 67082-67083 and 67105-67108, November 1, 2010). However, Commerce's notice...

  9. 76 FR 39896 - Granular Polytetrafluoroethylene Resin From Italy

    Science.gov (United States)

    2011-07-07

    ... Polytetrafluoroethylene Resin From Italy Determination On the basis of the record \\1\\ developed in the subject five-year... granular polytetrafluoroethylene resin from Italy would be likely to lead to continuation or recurrence of... Polytetrafluoroethylene Resin from Italy: Investigation No. 731-TA-385 (Third Review). By order of the Commission. Issued...

  10. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  11. 40 CFR 721.3135 - Phosphorous modified epoxy resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Phosphorous modified epoxy resin... Specific Chemical Substances § 721.3135 Phosphorous modified epoxy resin (generic). (a) Chemical substance... phosphorous modified epoxy resin (PMNs P-00-992 and P-01-471) is subject to reporting under this section for...

  12. 40 CFR 721.2752 - Epoxy resin containing phosphorus (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Epoxy resin containing phosphorus... Specific Chemical Substances § 721.2752 Epoxy resin containing phosphorus (generic). (a) Chemical substance... epoxy resin containing phosphorus (PMN P-00-912) is subject to reporting under this section for the...

  13. 40 CFR 721.2755 - Cycloaliphatic epoxy resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Cycloaliphatic epoxy resin (generic... Substances § 721.2755 Cycloaliphatic epoxy resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as cycloaliphatic epoxy resin (PMN...

  14. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    Science.gov (United States)

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to

  15. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    Science.gov (United States)

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  16. Acid-base titrations for polyacids: Significance of the pK sub a and parameters in the Kern equation

    Science.gov (United States)

    Meites, L.

    1978-01-01

    A new method is suggested for calculating the dissociation constants of polyvalent acids, especially polymeric acids. In qualitative form the most significant characteristics of the titration curves are demonstrated and identified which are obtained when titrating the solutions of such acids with a standard base potentiometrically.

  17. On the virtue of acid–base titrations for the determination of basic sites in nitrogen doped carbon nanotubes

    NARCIS (Netherlands)

    Bitter, J.H.; van Dommele, S.; de Jong, K.P.

    2013-01-01

    The basicity and nature of basic species in nitrogen containing carbon nanotubes (NCNT) prepared under different conditions were investigated by acid–base titrations. Proton uptake curves were derived from the titration data and were used to establish the basicity (pKa) ranges of nitrogen species

  18. The Quantitative Resolution of a Mixture of Group II Metal Ions by Thermometric Titration with EDTA. An Analytical Chemistry Experiment.

    Science.gov (United States)

    Smith, Robert L.; Popham, Ronald E.

    1983-01-01

    Presents an experiment in thermometric titration used in an analytic chemistry-chemical instrumentation course, consisting of two titrations, one a mixture of calcium and magnesium, the other of calcium, magnesium, and barium ions. Provides equipment and solutions list/specifications, graphs, and discussion of results. (JM)

  19. Determination of the point-of-zero, charge of manganese oxides with different methods including an improved salt titration method

    NARCIS (Netherlands)

    Tan, W.F.; Lu, S.J.; Liu, F.; Feng, X.H.; He, J.Z.; Koopal, L.K.

    2008-01-01

    Manganese (Mn) oxides are important components in soils and sediments. Points-of-zero charge (PZC) of three synthetic Mn oxides (birnessite, cryptomelane, and todorokite) were determined by using three classical techniques (potentiometric titration or PT, rapid PT or R-PT, and salt titration or ST)

  20. Safety of a web-based insulin titration system for patients with type 2 diabetes mellitus - pilot study

    NARCIS (Netherlands)

    Simon, A. C. R.; Holleman, F.; Gude, W. T.; Hoekstra, J. B. L.; Peek, N.

    2012-01-01

    The treatment of type 2 diabetes patients with insulin requires active dose titration to obtain optimal glycemic control. We developed a web-based decision support system to guide patients in performing the titration task autonomously, at their homes. The system is based on a clinically validated

  1. Low-melt Viscosity Polyimide Resins for Resin Transfer Molding (RTM) II

    Science.gov (United States)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.; Scheiman, Daniel A.; Nguyen, Baochau N.; McCorkle, Linda S.

    2007-01-01

    A series of polyimide resins with low-melt viscosities in the range of 10-30 poise and high glass transition temperatures (Tg s) of 330-370 C were developed for resin transfer molding (RTM) applications. These polyimide resins were formulated from 2,3,3 ,4 -biphenyltetracarboxylic dianhydride (a-BPDA) with 4-phenylethynylphthalic anhydride endcaps along with either 3,4 - oxyaniline (3,4 -ODA), 3,4 -methylenedianiline, (3,4 -MDA) or 3,3 -methylenedianiline (3,3 -MDA). These polyimides had pot lives of 30-60 minutes at 260-280 C, enabling the successful fabrication of T650-35 carbon fiber reinforced composites via RTM process. The viscosity profiles of the polyimide resins and the mechanical properties of the polyimide carbon fiber composites will be discussed.

  2. Resin Flow in Fiber Preformed by Vacuum Assisted Resin Transfer Molding with Flexible Tools

    Directory of Open Access Journals (Sweden)

    M.M. Shokrieh

    2008-12-01

    Full Text Available Vacuum assisted resin transfer molding, as a sub-branch of RTM is a method of manufacturing composite specimens. Considering the industrial development of this method, different modified techniques are designed to improve its performance. Among these techniques, using a half flexible mold is regarded as an important method. In this work, dominant equations of resin flow through the mold in polar coordinates are solved analytically. Based on this approach, closed-form solutions have been presented for different parameters such as thickness variation of preformed fiber, resin pressure, resin velocity and fiber volume fraction as functions of two variables, namely, time and the distance from injection port. After verification of the approach employed in this work, the results are presented. Important parameters influencing the quality and the rate production are studied in detail.

  3. Kuidas sünnib pealkiri? / Pärt Lias

    Index Scriptorium Estoniae

    Lias, Pärt

    2002-01-01

    Pealkiri, pühendus, moto, joonealune märge, ees- ja järelsõna on teose teksti manused, mis ei kuulu otse teksti, kuid selgitavad, täiendavad ja täpsustavad seda. Gerard Genette on need teksti lisandid koondanud üldnimetuse paratekstid alla. Eesti kirjanikud vastavad Pärt Liase küsimusele oma teoste pealkirjade saamisloo kohta: Aimee Beekman, Henn-Kaarel Hellat, Joel Sang ja Arvo Mägi (4); Lennart Meri, Heino Kiik ja Fanny de Sivers (5); Helga Nõu, Ülle Kauksi, Maie Kalda ja Cornelius Hasselblatt (6); Debora Vaarandi, Vaino Vahing, Arved Viirlaid ja Wimberg (7); Vahur Afanasjev, Matt Barker, Andrus Kivirähk, Jürgen Rooste ja Contra (8); Elin Toona, Jaak Rähesoo, Enn Soosaar, Juhan Peegel ja Toomas Kall (9); Kerttu Rakke, Aare Pilv, Aarne Ruben, Indrek Hargla, Jan Kaus ja Karen Orlau (10); Ene Mihkelson, Mats Traat ja Boriss Baljasnõi (11); Maimu Berg, Ain Kaalep, Enn Nõu ja Madis Kõiv (12)

  4. Factors influencing the use of RT in NSW: a qualitative study exploring consumer and health professional practices

    International Nuclear Information System (INIS)

    Sundaresan, Puma; Milross, Christopher G.; Stockler, Martin R.; Smith, Andrea; Evans, Alison; King, Madeleine T.

    2014-01-01

    Radiotherapy (RT) is an essential and cost-effective cancer treatment. It is underutilised in Australia. Bridging the gap between actual and optimal RT utilisation requires not only provision of adequate RT infrastructure but also an understanding of the factors that influence the extent to which this opportunity for RT is utilised. This study explored factors perceived to affect RT-related decision making by consumers and health professionals (HPs). Six semi-structured focus groups (FGs) and 13 interviews were conducted at three geographical locations in NSW, Australia (n=26 consumers and 30 HPs). Audio recordings of FGs and interviews were transcribed verbatim and analysed thematically. An exhaustive list of issues perceived to affect consumer and HP RT decisions was identified. There were common themes across participant groups and locations. Perceptions of RT and its benefits, as well as accurate communication of the expected benefits and risks of RT, were highlighted as important to decision making. Perceived factors relating to 'inconvenience' of RT were multifaceted and included travel, relocation, accommodation, time away from work and financial challenges. Perceived potential barriers to RT referral included knowledge of RT and RT services, availability of a local or visiting RT service, referrer bias, and the low profile of RT. Important drivers during RT decisions appear to include the perceived benefit, risks and inconvenience of RT. Underutilisation of RT may also result from multiple barriers at the referrer level. Further research into whether these factors influence actual RT decisions is needed.

  5. Classification of calorimetric titration plots for alkyltrimethylammonium and alkylpyridinium cationic surfactants in aqueous solutions

    NARCIS (Netherlands)

    Bijma, K; Engberts, J.B.F.N.; Blandamer, M.J; Cullis, P.M.; Last, P.M.; Irlam, K.D.; Soldi, L.G.

    1997-01-01

    Calorimetric titration plots for deaggregation of micelles formed by alkylpyridinium and alkyltrimethylammonium surfactants are classified into three types, A, B and C, depending on the shape of the plot of the enthalpy of dilution as a function of surfactant concentration. For Type A plots the

  6. An open-label Optional Titration Trial to Evaluate the Efficacy ...

    African Journals Online (AJOL)

    An open-label Optional Titration Trial to Evaluate the Efficacy, Tolerability and Safety of Valsartan in Patients with Mild to Moderate Essential Hypertension Treated for 8 Weeks in the Lagos University Teaching Hospita. ... Only 5(8%) developed self limiting side effects known to be associated with the use of Valsartan. 3(5%) ...

  7. Evaluation of the number of ionogenic groups of inulinase by acid-base titration.

    Science.gov (United States)

    Kovaleva, T A; Holyavka, M G; Rezvan, S G; Kozhedub, S V

    2008-06-01

    Acid base titration showed that Aspergillus awamori inulinase includes 178 asparaginic and glutamic acid residues, 20 histidine, 10 serine, and 34 lysine and tyrosine residues. Denaturation temperature for this enzyme was calculated using analysis of the proportion of stabilizing and destabilizing amino acids in the molecule.

  8. Trace analysis of acids and bases by conductometric titration with multiparametric non-linear regression.

    Science.gov (United States)

    Coelho, Lúcia H G; Gutz, Ivano G R

    2006-03-15

    A chemometric method for analysis of conductometric titration data was introduced to extend its applicability to lower concentrations and more complex acid-base systems. Auxiliary pH measurements were made during the titration to assist the calculation of the distribution of protonable species on base of known or guessed equilibrium constants. Conductivity values of each ionized or ionizable species possibly present in the sample were introduced in a general equation where the only unknown parameters were the total concentrations of (conjugated) bases and of strong electrolytes not involved in acid-base equilibria. All these concentrations were adjusted by a multiparametric nonlinear regression (NLR) method, based on the Levenberg-Marquardt algorithm. This first conductometric titration method with NLR analysis (CT-NLR) was successfully applied to simulated conductometric titration data and to synthetic samples with multiple components at concentrations as low as those found in rainwater (approximately 10 micromol L(-1)). It was possible to resolve and quantify mixtures containing a strong acid, formic acid, acetic acid, ammonium ion, bicarbonate and inert electrolyte with accuracy of 5% or better.

  9. Developing a multipoint titration method with a variable dose implementation for anaerobic digestion monitoring.

    Science.gov (United States)

    Salonen, K; Leisola, M; Eerikäinen, T

    2009-01-01

    Determination of metabolites from an anaerobic digester with an acid base titration is considered as superior method for many reasons. This paper describes a practical at line compatible multipoint titration method. The titration procedure was improved by speed and data quality. A simple and novel control algorithm for estimating a variable titrant dose was derived for this purpose. This non-linear PI-controller like algorithm does not require any preliminary information from sample. Performance of this controller is superior compared to traditional linear PI-controllers. In addition, simplification for presenting polyprotic acids as a sum of multiple monoprotic acids is introduced along with a mathematical error examination. A method for inclusion of the ionic strength effect with stepwise iteration is shown. The titration model is presented with matrix notations enabling simple computation of all concentration estimates. All methods and algorithms are illustrated in the experimental part. A linear correlation better than 0.999 was obtained for both acetate and phosphate used as model compounds with slopes of 0.98 and 1.00 and average standard deviations of 0.6% and 0.8%, respectively. Furthermore, insensitivity of the presented method for overlapping buffer capacity curves was shown.

  10. Automation of potentiometric titration for the determination of uranium in nuclear fuel materials

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Pandey, Ashish; Kapoor, Y.S.; Kumar, Manish; Singh, Mamta; Fulzele, Ajeet; Prakash, Amrit; Afzal, Mohd; Panakkal, J.P.

    2010-01-01

    Advanced Fuel Fabrication Facility is fabricating various types of mixed oxide fuels, namely for PHWR, BWR, FBTR and PFBR. Precise determination of uranium in MOX fuel sample is important to get desired burn up in the reactor. The modified Davies and Gray method is routinely used for the potentiometric titration of uranium

  11. Tested Demonstrations: Comparison of Strong Acid and Weak Acid Titration Curves.

    Science.gov (United States)

    Gilbert, George L., Ed.

    1979-01-01

    A lecture demonstration is presented for comparing titration curves. A plot of pH vs volume of strong base is produced by connecting the external output of a pH meter to a strip recorder. Thus, pH is recorded as a function of time. (BB)

  12. Thermometric titration of some monoprotic and diprotic acids in aqueous and non-aqueous media.

    Science.gov (United States)

    Harries, R J

    1968-12-01

    Some mono- and diprotic acids have been titrated thermometrically with strong alkalis in aqueous and non-aqueous media. Thermograms with sharp arrest points were obtained, from which heats of neutralization were measured. Heats of neutralization in the media used were compared and an effect attributable to hydrogen bonding was found.

  13. Determination of oxygen nonstoichiometry and diffusivity in mixed conducting oxides by oxygen Coulometric titration

    NARCIS (Netherlands)

    Lankhorst, M.H.R.; Lankhorst, Martijn H.R.; Bouwmeester, Henricus J.M.

    1997-01-01

    Oxygen coulometric titration has been applied to measure chemical diffusion in La0.8Sr0.2CoO3-δ between 700 and 1000°C. The transient current response to a potentiostatic step has been transformed from the time domain to the frequency domain. The equivalent circuit used to fit the resulting

  14. DETERMINATION OF WATER CONTENT IN PYROLYTIC TARS USING COULOMETRIC KARL-FISHER TITRATION

    Directory of Open Access Journals (Sweden)

    Lenka Jílková

    2017-02-01

    Full Text Available The liquid organic fraction of pyrolytic tar has a high energy value which makes possible its utilization as an energy source. However, before utilization, it is crucial to remove water from the liquid fraction. The presence of water reduces the energy value of pyrolytic tars. Water separation from the organic tar fraction is a complex process, since an emulsion can be readily formed. Therefore, after phase separation, it is important to know the residual water content in the organic phase and whether it is necessary to further dry it. The results presented in this manuscript focus on a water determination in liquid products from coal and biomass pyrolysis by a coulometric Karl‑Fischer titration. The Coulometric Karl‑Fischer titration is often used for a water content determination in gaseous, liquid and solid samples. However, to date, this titration method has not been used for a water determination in tars. A new water determination method, which has been tested on different types of tar, has been developed. The Coulometric Karl‑Fischer titration is suitable for tar samples with a water content not greater than 5 wt. %. The obtained experimental results indicate that the new introduced method can be used with a very good repeatability for a water content determination in tars.

  15. Single-experiment displacement assay for quantifying high-affinity binding by isothermal titration calorimetry.

    Science.gov (United States)

    Krainer, Georg; Keller, Sandro

    2015-04-01

    Isothermal titration calorimetry (ITC) is the gold standard for dissecting the thermodynamics of a biomolecular binding process within a single experiment. However, reliable determination of the dissociation constant (KD) from a single titration is typically limited to the range 100 μM>KD>1 nM. Interactions characterized by a lower KD can be assessed indirectly by so-called competition or displacement assays, provided that a suitable competitive ligand is available whose KD falls within the directly accessible window. However, this protocol is limited by the fact that it necessitates at least two titrations to characterize one high-affinity inhibitor, resulting in considerable consumption of both sample material and time. Here, we introduce a fast and efficient ITC displacement assay that allows for the simultaneous characterization of both a high-affinity ligand and a moderate-affinity ligand competing for the same binding site on a receptor within a single experiment. The protocol is based on a titration of the high-affinity ligand into a solution containing the moderate-affinity ligand bound to the receptor present in excess. The resulting biphasic binding isotherm enables accurate and precise determination of KD values and binding enthalpies (ΔH) of both ligands. We discuss the theoretical background underlying the approach, demonstrate its practical application to metal ion chelation, explore its potential and limitations with the aid of simulations and statistical analyses, and elaborate on potential applications to protein-inhibitor interactions. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Improving manual oxygen titration in preterm infants by training and guideline implementation

    NARCIS (Netherlands)

    van Zanten, Henriëtte A; Pauws, Steffen C; Beks, Evelien C; Stenson, Ben J; Lopriore, Enrico; Te Pas, Arjan B

    To study oxygen saturation (SpO2) targeting before and after training and guideline implementation of manual oxygen titration, two cohorts of preterm infants <30 weeks of gestation needing respiratory support and oxygen therapy were compared. The percentage of the time spent with SpO2 within the

  17. An Exact Method to Determine the Conductivity of Aqueous Solutions in Acid-Base Titrations

    Directory of Open Access Journals (Sweden)

    Norma Rodríguez-Laguna

    2015-01-01

    Full Text Available Several works in the literature show that it is possible to establish the analytic equations to estimate the volume V of a strong base or a strong acid (Vb and Va, resp. being added to a solution of a substance or a mix of substances during an acid-base titration, as well as the equations to estimate the first derivative of the titration plot dpH/dV, and algebraic expressions to determine the buffer β capacity with dilution βdil. This treatment allows establishing the conditions of thermodynamic equilibria for all species within a system containing a mix of species from one or from various polyacid systems. The present work shows that it is possible to determine exactly the electric conductivity of aqueous solutions for these Brønsted acid-base titrations, because the functional relation between this property and the composition of the system in equilibrium is well known; this is achieved using the equivalent conductivity λi values of each of the ions present in a given system. The model employed for the present work confirms the experimental outcomes with the H2SO4, B(OH3, CH3COOH, and H3PO4 aqueous solutions’ titration.

  18. pH and Titratable Acidity of different Cough Syrups in Nigeria ...

    African Journals Online (AJOL)

    Background: Cough linctuses are liquid oral medicines widely used in children to treat cough and related conditions. Some of their constituents are acidic and dental erosive. Objectives: This in vitro study aimed to evaluate the endogenous pH and titratable acidity of Nigerian cough syrups and also determine their erosive ...

  19. Development and validation of a simplified titration method for monitoring volatile fatty acids in anaerobic digestion.

    Science.gov (United States)

    Sun, Hao; Guo, Jianbin; Wu, Shubiao; Liu, Fang; Dong, Renjie

    2017-09-01

    The volatile fatty acids (VFAs) concentration has been considered as one of the most sensitive process performance indicators in anaerobic digestion (AD) process. However, the accurate determination of VFAs concentration in AD processes normally requires advanced equipment and complex pretreatment procedures. A simplified method with fewer sample pretreatment procedures and improved accuracy is greatly needed, particularly for on-site application. This report outlines improvements to the Nordmann method, one of the most popular titrations used for VFA monitoring. The influence of ion and solid interfering subsystems in titrated samples on results accuracy was discussed. The total solid content in titrated samples was the main factor affecting accuracy in VFA monitoring. Moreover, a high linear correlation was established between the total solids contents and VFA measurement differences between the traditional Nordmann equation and gas chromatography (GC). Accordingly, a simplified titration method was developed and validated using a semi-continuous experiment of chicken manure anaerobic digestion with various organic loading rates. The good fitting of the results obtained by this method in comparison with GC results strongly supported the potential application of this method to VFA monitoring. Copyright © 2017. Published by Elsevier Ltd.

  20. Statistical evaluation of an interlaboratory comparison for the determination of uranium by potentiometric titration

    International Nuclear Information System (INIS)

    Ketema, D.J.; Harry, R.J.S.; Zijp, W.L.

    1990-09-01

    Upon request of the ESARDA working group 'Low enriched uranium conversion - and fuel fabrication plants' an interlaboratory comparison was organized, to assess the precision and accuracy concerning the determination of uranium by the potentiometric titration method. This report presents the results of a statistical evaluation on the data of the first phase of this exercise. (author). 9 refs.; 5 figs.; 24 tabs