WorldWideScience

Sample records for resin titration rt

  1. Quantitative RT-PCR for titration of replication-defective recombinant Semliki Forest virus.

    Science.gov (United States)

    Puglia, Ana L P; Rezende, Alexandre G; Jorge, Soraia A C; Wagner, Renaud; Pereira, Carlos A; Astray, Renato M

    2013-11-01

    Virus titration may constitute a drawback in the development and use of replication-defective viral vectors like Semliki Forest virus (SFV). The standardization and validation of a reverse transcription quantitative PCR (qRT-PCR) method for SFV titration is presented here. The qRT-PCR target is located within the nsp1 gene of the non-structural polyprotein SFV region (SFV RNA), which allows the strategy to be used for several different recombinant SFV constructs. Titer determinations were carried out by performing virus titration and infection assays with SFVs containing an RNA coding region for the rabies virus glycoprotein (RVGP) or green fluorescent protein (GFP). Results showed that the standardized qRT-PCR is applicable for different SFV constructs, and showed good reproducibility. To evaluate the correlation between the amount of functional SFV RNA in a virus lot and its infectivity in BHK-21 cell cultures, a temperature mediated titer decrease was performed and successfully quantitated by qRT-PCR. When used for cell infection at the same multiplicity of infection (MOI), the temperature treated SFV-RVGP samples induced the same levels of RVGP expression. Similarly, when different SFV-GFP lots with different virus titers, as accessed by qRT-PCR, were used for cell infection at the same MOI, the cultures showed comparable amounts of fluorescent cells. The data demonstrate a good correlation between the amount of virus used for infection, as measured by its SFV RNA, and the protein synthesis in the cells. In conclusion, the qRT-PCR method developed here is accurate and enables the titration of replication-defective SFV vectors, an essential aid for viral vector development as well as for establishment of production bioprocesses. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Isothermal Titration Calorimetry and Fluorescence Spectroscopy Study Of Asphaltene Self-Association In Toluene And Interaction With A Model Resin

    DEFF Research Database (Denmark)

    Garcia, Daniel Merino; Andersen, Simon Ivar

    2002-01-01

    This article collects the work performed by Isothermal Titration Caloritnetry (ITC) in the study of the self-association of asphaltenes in toluene solutions. Calorimetric experiments show that asphaltenes, start self-associating at very low concentrations and that the existence of a Critical...... with the results of the titration of three model molecules: nonylphenol, which associates by means of hydrogen bond formation, and coronene and pyrene, which associates by stacking. The results obtained leave open the question about the model-stacking molecules, as it was not possible to elucidate whether they do...

  3. LIGHT TITRATIONS

    Science.gov (United States)

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  4. Thermometric titration of sulphate.

    Science.gov (United States)

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  5. Potentiometric titration of plutonium

    International Nuclear Information System (INIS)

    Silver, G.L.

    1978-01-01

    In the potentiometric titration of plutonium(III), it has been customary to take the equivalence point as the inflection point on a plot of potential vs. volume of titrant. It have not been, however, demonstrated, that the stoichiometric end point corresponds to the inflection point. Suggestions are made according to which these points may not correspond in the potentiometric titration of plutonium(III), as these titrations are ordinarily concluded in a period of time which is short compared to the time required for valence state rearrangement through disproportionation. (T.G.)

  6. Automated uranium titration system

    International Nuclear Information System (INIS)

    Takahashi, M.; Kato, Y.

    1983-01-01

    An automated titration system based on the Davies-Gray method has been developed for accurate determination of uranium. The system consists of a potentiometric titrator with precise burettes, a sample changer, an electronic balance and a desk-top computer with a printer. Fifty-five titration vessels are loaded in the sample changer. The first three contain the standard solution for standardizing potassium dichromate titrant, and the next two and the last two contain the control samples for data quality assurance. The other forty-eight measurements are carried out for sixteen unknown samples. Sample solution containing about 100 mg uranium is taken in a titration vessel. At the pretreatment position, uranium (VI) is reduced to uranium (IV) by iron (II). After the valency adjustment, the vessel is transferred to the titration position. The rate of titrant addition is automatically controlled to be slower near the end-point. The last figure (0.01 mL) of the equivalent titrant volume for uranium is calculated from the potential change. The results obtained with this system on 100 mg uranium gave a precision of 0.2% (RSD,n=3) and an accuracy of better than 0.1%. Fifty-five titrations are accomplished in 10 hours. (author)

  7. Filtrates & Residues: Olfactory Titration.

    Science.gov (United States)

    Wood, John T.; Eddy, Roberta M.

    1996-01-01

    Presents an experiment that uses a unique acid-base indicator--the odor of raw onion--to indicate the end point of the titration of sodium hydroxide with hydrochloric acid. Allows the student to detect the completion of the neutralization reaction by olfaction rather than sight. (JRH)

  8. ''Titration'' polymerization of monovinylacetylene

    NARCIS (Netherlands)

    Mavinkurve, A; Visser, S; vandenBroek, W; Pennings, AJ

    1996-01-01

    A polymer consisting of a saturated carbon backbone with pendent acetylenic groups was prepared from monovinylacetylene. A titration was performed between the monomer and tertiary butyllithium, its lithiating agent. The charge transfer complex formed between the solvent THF and the tertiary

  9. Titration Curves: Fact and Fiction.

    Science.gov (United States)

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  10. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  11. Potentiometric titration and equivalent weight of humic acid

    Science.gov (United States)

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  12. Modified ion exchange resins - synthesis and properties. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Doescher, F.; Klein, J.; Pohl, F.; Widdecke, H.

    1982-01-22

    Sulfomethylated resins are prepared by polymer analogous reactions, starting from macroporous poly(styrene-co-divinylbenzene) matrices. Different reaction paths are discussed and used in the synthesis. Sulfomethylation can be achieved by reaction of a chloromethylated resin with dimethyl sulfide and sodium sulfonate or alternatively by oxidation of polymer-bound thiol groups. Both methods give high conversions as shown by IR spectra and titration of the sulfonic acid groups. Poly(1-(4-hydroxysulfomethylphenyl)ethylene) (3) is obtained by reaction of poly(1-(4-hydroxyphenyl)ethylene) (2) resin with formaldehyde/sodium sulfonate. The thermal stability, catalytic activity, and ion exchange equilibria of the sulfomethylated resin are investigated.

  13. Amperometric, Bipotentiometric, and Coulometric Titration.

    Science.gov (United States)

    Stock, John T.

    1980-01-01

    Discusses recent review articles in various kinds of titration. Also discusses new research in apparatus and methodology, acid-base reactions, precipitation and complexing reactions, oxidation-reduction reactions, and nomenclature. Cites 338 references. (CS)

  14. Resin composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Peutzfeldt, Anne; Lussi, Adrian

    2014-01-01

    OBJECTIVE: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity...... of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p....008). CONCLUSIONS: The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE: The results from this study suggest that the marginal quality of restorations can...

  15. TAPIR: a device for automatic titration with incremental weighing of the titration reagent

    International Nuclear Information System (INIS)

    Ganivet, Michel

    TAPIR is a titration device enabling automatic analyses with weighting of the titration reagent. The titration method used can be based on potentiometry, amperometry, color indicator change... The reproducibility is about 3.10 -4 [fr

  16. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  17. Automated back titration method to measure phosphate

    International Nuclear Information System (INIS)

    Comer, J.; Tehrani, M.; Avdeef, A.; Ross, J. Jr.

    1987-01-01

    Phosphate was measured in soda drinks and as an additive in flour, by a back titration method in which phosphate was precipitated with lanthanum, and the excess lanthanum was titrated with fluoride. All measurements were performed using the Orion fluoride electrode and the Orion 960 Autochemistry System. In most commercial automatic titrators, the inflection point of the titration curve, calculated from the first derivative of the curve, is used to find the equivalence polar of the titration. The inflection technique is compared with a technique based on Gran functions, which uses data collected after the end point and predicts the equivalence point accordingly

  18. Automatic titrator for high precision plutonium assay

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.

    1986-01-01

    Highly precise assay of plutonium metal is required for accountability measurements. We have developed an automatic titrator for this determination which eliminates analyst bias and requires much less analyst time. The analyst is only required to enter sample data and start the titration. The automated instrument titrates the sample, locates the end point, and outputs the results as a paper tape printout. Precision of the titration is less than 0.03% relative standard deviation for a single determination at the 250-mg plutonium level. The titration time is less than 5 min

  19. Immobilization of spent resin with epoxy resin

    International Nuclear Information System (INIS)

    Gultom, O.; Suryanto; Sayogo; Ramdan

    1997-01-01

    immobilization of spent resin using epoxy resin has been conducted. The spent resin was mixtured with epoxy resin in variation of concentration, i.e., 30, 40, 50, 60, 70 weight percent of spent resin. The mixture were pour into the plastic tube, with a diameter of 40 mm and height of 40 mm. The density, compressive strength and leaching rate were respectively measured by quanta chrome, paul weber apparatus and gamma spectrometer. The results showed that the increasing of waste concentration would be decreased the compressive strength, and increased density by immobilized waste. The leaching rate of 137 Cs from waste product was not detected in experiment (author)

  20. Risks and Benefits of Rapid Clozapine Titration.

    Science.gov (United States)

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  1. Risks and benefits of rapid clozapine titration

    Directory of Open Access Journals (Sweden)

    Jeannie D. Lochhead

    2016-05-01

    Full Text Available Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  2. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  3. Contributions to the theory of catalytic titrations-III Neutralization catalytic titrations.

    Science.gov (United States)

    Gaál, F F; Abramović, B F

    1985-07-01

    Neutralization catalytic titrations of weak monoprotic adds and bases with both volumetric and coulometric addition of the titrant (strong base/acid) have been simulated by taking into account the equilibrium concentration of the catalyst during the titration. The influence of several factors on the shape of the simulated catalytic titration curve has been investigated and is discussed.

  4. A titration model for evaluating calcium hydroxide removal techniques

    Directory of Open Access Journals (Sweden)

    Mark PHILLIPS

    2015-02-01

    Full Text Available Objective Calcium hydroxide (Ca(OH2 has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH2 left after different endodontic irrigation methods. Material and Methods Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH2 followed by gross Ca(OH2 removal using hand files and randomized treatment of either: 1 Syringe irrigation; 2 Syringe irrigation with use of an apical file; 3 Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI, or 4 Syringe irrigation with apical file and PUI (n=12/group. Residual Ca(OH2 was dissolved with glycerin and titrated to measure residual Ca(OH2 left in the root. Results No method completely removed all residual Ca(OH2. The addition of 30 s PUI with or without apical file use removed Ca(OH2 significantly better than irrigation alone. Conclusions This technique allowed quantification of residual Ca(OH2. The use of PUI (with or without apical file resulted in significantly lower Ca(OH2 residue compared to irrigation alone.

  5. A Tabular Approach to Titration Calculations

    Science.gov (United States)

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  6. Symmetry Properties of Potentiometric Titration Curves.

    Science.gov (United States)

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  7. Potentiometric titration of metal ions in ethanol.

    Science.gov (United States)

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  8. Potentiometric Titration Method for Quantitative Determination of Hydrogen Peroxide

    National Research Council Canada - National Science Library

    Bessette, Russell R

    2005-01-01

    An electrochemical potentiometric titration method that entails titration of a known volume of a catholyte containing an unknown amount of hydrogen peroxide in a titration cell having two electrodes...

  9. Linear Titration Curves of Acids and Bases.

    Science.gov (United States)

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  10. Non-aqueous titration of hydroxamic acids.

    Science.gov (United States)

    Stamey, T W; Christian, R

    1966-01-01

    Benzohydroxamic acid is titrated with 0.1M tetrabutyl-anunonium hydroxide in nine non-aqueous solvents with three different indicating electrodes. The best results are obtained using dimethylformamide as solvent and platinum-platinum electrodes. Four monoprotic and three diprotic hydroxamie acids and iron(III) benzohydroxamate have been successfully titrated with this system. The effect of quantitative additions of carbon dioxide to the titrant on its apparent molarity are found to be dependent on the amount added, the strength and sample size of acid titrated and the solvent used.

  11. Determination of substances by radiothermometric titration

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.

    1976-01-01

    For determination, nitrogen is bubbled through a solution containing radioactive Kr, Xe, Rn or another aerogen in addition to the substance determined. A continuous or intermittent addition of the titrating solution results in the release of reaction heat, thus increasing the temperature of the reaction mixture, which releases a radioactive gas. Upon reaching the equivalence point, the cold titrating reagent cools the reaction mixture, thus reducing the radioactive substance release. The equivalence point lies at the point of intersection of the extended linear parts of the curve of the dependence of released radioactivity on the volume of the titrating solution added. (M.K.)

  12. Removal of aluminum(III)-based turbidity in water using hydrous titanium oxide dispersed in ion-exchange resins

    International Nuclear Information System (INIS)

    Venkataramani, B.; Karweer, S.B.; Iyer, R.K.; Phatak, G.M.; Iyer, R.M.

    1988-01-01

    An adsorber consisting of hydrous titanium oxide (HTiO) dispersed in a Dowex-type ion-exchange resin matrix (designated RT resins) has been developed which is capable of removing Al(III)-based colloidal dispersions in the neutral pH condition. The effect of resin crosslinking, particle size, HTiO loading, turbidity level, and flow rate on the turbidity removal efficiency of RT resins has been studied. It is demonstrated that a train of columns comprising RT resin, H + , and OH - form of resins could be used for large-scale purification operations at high flow rates. These columns, apart from removing turbidity and associated radioactivity, can effectively remove dissolved uranium present in ppb levels when used for water purification in nuclear reactors

  13. Synthesis and characterization of an N-(2-hydroxyethyl)-ethylenediaminetriacetic acid resin

    International Nuclear Information System (INIS)

    Lai, Y.F.

    1977-10-01

    A chelating ion-exchange resin with N-(2-hydroxyethyl)ethylene-diaminetriacetic acid (HEDTA) used as the ligand chemically bonded to XAD-4 by an ester linkage, HEDTA-4, was synthesized. It is stable under normal experimental conditions with the liquid chromatograph. The structure of the resin was confirmed by an infrared spectrum, and by potentiometric titrations. The capacity of the resin was also obtained by potentiometric titration and by a nitrogen analysis. The resin was used to pack a column of 5 mm internal diameter and 5 cm long. The effect of pH on the retention of different metal ions on the resin was studied. It was found that the resin was most selective for chromium(III), copper(II), lead(II), mercury(II), uranium(VI), zirconium(IV) and zinc(II) at a pH of less than 3. Furthermore, the resin proves to be functioning with a chelating mechanism rather than ion-exchange, and it can concentrate trace metal ions in the presence of a large excess of calcium and magnesium. This makes the resin potentially useful for purifying and analyzing drinking water

  14. Titrated Misoprostol Versus Dinoprostone for Labor Induction

    African Journals Online (AJOL)

    Aim: This study designed to compare titrated misoprostol regarding its safety and efficacy with dinoprostone for induction of labor. ... Statistical analysis done using Student's t-test for quantitative data and ..... induction: A pilot study. Rev Bras ...

  15. Non-aqueous titration of benzotrifuroxan (BTF)

    Energy Technology Data Exchange (ETDEWEB)

    Selig, W.

    1978-01-01

    This compound can be titrated potentiometrically as an acid with tetrabutylammonium hydroxide in dimethylformamide, dimethylsulfoxide, acetone, pyridine, tetramethylguanidine. The solvent of choice is dimethylformamide which yields the steepest titration curve and the lowest standard deviation. The equivalent weight of benzotrifuroxan is dependent on the solvent used indicating a strong interaction with the solvent. In dimethylformamide, the equivalent weight of benzotrifuroxan is 151.3, corresponding to 1.67 equivalents per mole.

  16. Theory of titration curves-VII The properties of derivative titration curves for strong acid-strong base and other isovalent ion-combination titrations.

    Science.gov (United States)

    Meites, T; Meites, L

    1970-06-01

    This paper deals with isovalent ion-combination titrations based on reactions that can be represented by the equation M(n+) + X(n-) --> MX, where the activity of the product MX is invariant throughout a titration, and with the derivative titration curves obtained by plotting d[M(+)]/dfversus f for such titrations. It describes some of the ways in which such curves can be obtained; it compares and contrasts them both with potentiometric titration curves, which resemble them in shape, and with segmented titration curves, from which they are derived; and it discusses their properties in detail.

  17. A maturation method of uranium content in resins with acid dissolution

    International Nuclear Information System (INIS)

    Liu Yang

    2010-01-01

    Acid dissolution method is that with intensively oxidation acid to decompose ion exchanging resins and dissolving U and Fe ion in water, then menstruate the U content by titration. Comparing with our current method of filtering wash, acid dissolution menstruation U can get more accurate result and take less time, use more simple device. (authors)

  18. Coulometric titration at low temperatures-nonstoichiometric silver selenide

    OpenAIRE

    Beck, Gesa K.; Janek, Jürgen

    2003-01-01

    A modified coulometric titration technique is described for the investigation of nonstoichiometric phases at low temperatures. It allows to obtain titration curves at temperatures where the conventional coulometric titration technique fails because of too small chemical diffusion coefficients of the mobile component. This method for indirect coulometric titration is applied to silver selenide between -100 and 100 °C. The titration curves are analyzed on the basis of a defect chemical model an...

  19. Ion exchange resin fouling of molybdenum in recovery uranium processess

    International Nuclear Information System (INIS)

    Zhang Guowei; Zhao Guirong

    1990-09-01

    The relationship between anion exchange resin fouling and molybdic acid polymerization was studied. By using potentiometer titration and laser-Raman spectroscopy the relationship of molybdic acid polymerization and the pH value of solution or the molybdenum concentration was determined. It was shown that as the concentration of initial molybdenum in solution decreases from 0.2 mol/L to 0.5 mmol/L, the pH value of starting polymerization decreased from 6.5 to 4.5. The experimental results show that the fouling of 201 x 7 resin in the acidic solution is mainly caused by the adsorbing of Mo 3 O 26 4- ion and occupying the exchange radical site of the resin. Under the leaching conditions the molybdenum and phosphate existing in the leaching liquor can form 12-molybdo-phosphate ion. It also leads to resin fouling. The molybdenum on the fouled resin can synergically be desorbed by mixed desorbents containing ammonium hydroxide and ammonium sulfate. The desorbed resin can be used for uranium adsorption and the desorbed molybdenum can be recovered by ion exchange method

  20. A generalized approach for the calculation and automation of potentiometric titrations Part 2. Redox Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    The very fast calculation procedure described earlier is applied to calculate the titration curves of complicated redox systems. The theory is extended slightly to cover inhomogeneous redox systems. Titrations of iodine or 2,6-dichloroindophenol with ascorbic acid are described. It is shown that

  1. End-point construction and systematic titration error in linear titration curves-complexation reactions

    NARCIS (Netherlands)

    Coenegracht, P.M.J.; Duisenberg, A.J.M.

    The systematic titration error which is introduced by the intersection of tangents to hyperbolic titration curves is discussed. The effects of the apparent (conditional) formation constant, of the concentration of the unknown component and of the ranges used for the end-point construction are

  2. Polyvinyl chloride resin

    International Nuclear Information System (INIS)

    Kim, Hong Jae

    1976-06-01

    This book contains polyvinyl chloride resin industry with present condition such as plastic industry and polyvinyl chloride in the world and Japan, manufacture of polyvinyl chloride resin ; suspension polymerization and solution polymerization, extruding, injection process, hollow molding vinyl record, vacuum forming, polymer powders process, vinyl chloride varnish, vinyl chloride latex, safety and construction on vinyl chloride. Each chapter has descriptions on of process and kinds of polyvinyl chloride resin.

  3. An accurate potentiometric titration of 5-25 mg uranium

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Lingerak, W.A.

    1976-01-01

    A potentiometric titration of 5 to 25 mg uranium is described. Sulphamic and phosphoric acid are added to the sample (volume 1 ml), U VI is reduced to U IV by Fe 2+ and the excess of Fe 2+ is oxidized by a mixture of nitric acid, sulphamic acid and ammonium molybdate; vanadyl sulphate is added to ensure a sharp end-point of the titration. The resultant U IV is titrated automatically with 0.02500N potassiumdichromate using a platinum indicator electrode. The automatic titration is performed both with a commercial titrator (Mettler) and with an R.C.N. titrator which waits after each addition until the equilibrium is reached. Using the Mettler titrator an accuracy of 0.05% relative was reached. The R.C.N. setpoint titrator gave results with an accuracy of 0.04% relative at the 20-mg U level. Each titration takes 5 to 7 min. (author)

  4. Isothermal Titration Calorimetry in the Student Laboratory

    Science.gov (United States)

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  5. Titration Calculations with Computer Algebra Software

    Science.gov (United States)

    Lachance, Russ; Biaglow, Andrew

    2012-01-01

    This article examines the symbolic algebraic solution of the titration equations for a diprotic acid, as obtained using "Mathematica," "Maple," and "Mathcad." The equilibrium and conservation equations are solved symbolically by the programs to eliminate the approximations that normally would be performed by the student. Of the three programs,…

  6. NBL-Davies-Gray weight titration method

    International Nuclear Information System (INIS)

    Hassell, C.

    1981-01-01

    The titration method for uranium consists of the following basic steps: reduction of U +6 to U +4 by Fe +2 ; selective oxidation of excess Fe +2 by HNO 3 with Mo +6 catalyst, all in strong phosphoric acid solution; and titration of the U +4 with standard dichromate after dilution. In this paper, detailed procedure of the NBL method, its modification to a gravimetric system or weight titration technique, and miniaturization of the NBL titrimetric method are discussed. Improved precisions and accuracy (2 to 3 times), of the gravimetric titrant delivery has made it possible to reduce the amount of uranium taken for each analysis. At present, using gravimetric delivery, most samples are titrated in the 30 to 50 mg range. Improved precision has led to investigating the possibility of a scaled-down version of the basic method so as to reduce the volume of phosphoric acid waste generated. Because all reactions are carried out in the same vessel, this method can be automated. Analysts at NBL have been able to restrict error to 0.05% or better in the 30 to 100 mg range using the basic procedure

  7. Acid Rain Analysis by Standard Addition Titration.

    Science.gov (United States)

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  8. An Olfactory Indicator for Acid-Base Titrations.

    Science.gov (United States)

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  9. Potentiometric titration curves of aluminium salt solutions and its ...

    African Journals Online (AJOL)

    Potentiometric titration curves of aluminium salt solutions and its species conversion ... of aluminium salt solutions under the moderate slow rate of base injection. ... silicate radical, and organic acid radical on the titration curves and its critical ...

  10. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  11. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    Science.gov (United States)

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Potentiometric determination of milligram amounts of uranium by semiautomatic titrator

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Stepanov, A.V.; Preobrazhenskaya, L.D.; Solntseva, L.F.; Gromova, E.A.

    1978-01-01

    A semiautomatic titrator is described which allows gravimetriotentiometricc-p titrat mg amounts of substances. Milligram amounts of uranium (absolute contents and oxygen/uranium ratio) in U 3 O 8 were determined as an example of the titrator action. The relative standard deviation was less than 0.001

  13. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    Science.gov (United States)

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  14. Separation and characterization of resins and asphaltenes coming from Castilla crude Evaluation of their molecular interaction

    International Nuclear Information System (INIS)

    Navarro, Lina; Alvarez, Mario; Grosso, Jorge Luis; Navarro, Uriel

    2004-01-01

    The study of resins and asphaltenes, the heaviest fractions of oil, has become an area of interest due to the abundance of heavy crude oils in Colombia and Latin America. We studied the chemical composition of the heavy fractions of Castilla crude oil, evaluated some of its molecular parameters and found evidence of the interaction between the resins extracted from the crude with the asphaltenes of the original crude. With this objective, we carried out at the pilot plant level precipitation of the resin-asphaltene (R-A) aggregate by adding and mixing under controlled conditions, a paraffin solvent, from the Apiay refinery, called Apiasol. By extracting Soxhlet with the same solvent, resin 1 of aggregate R-A was separated. Resin ll defined as the soluble fraction that is part of the maltenes, was separated from the deasphalted crude by open column chromatography, using alumina as support, according to the SAR method (Saturated, Aromatics, Resins). The fractions of resins and the asphaltenes obtained, were characterized by: Nuclear Magnetic Resonance (NMR), FT-lR, DRX, elementary analysis (C, H, N, S), metal content (Ni and V), distribution of molecular weight by GPC, and average molecular weight by VPO. The results obtained show evidence that resin l which is part of the aggregate has less average molecular weight than resin ll which is present in the fraction of maltenes. In addition, some changes were found in the elementary analysis of among the resins. On the one hand, and taking into account the existing theories of molecular interactions among these fractions, it was found that the resins l separated from the R-A aggregate, when added to the crude, they stabilize their asphaltenes. This evaluation was carried out by analyzing the flocculation point of the crude and its mixtures with 1,9% and 3,8% of resin l, when they are titrated with a precipitating agent in an NIR cell that works with high pressure and temperature

  15. Stabilization of the initial electrochemical potential for a metal-based potentiometric titration study of a biosorption process.

    Science.gov (United States)

    Naja, Ghinwa; Mustin, Christian; Volesky, Bohumil; Berthelin, Jacques

    2006-01-01

    An interactive metal-based potentiometric titration method has been developed using an ion selective electrode for studying the sorption of metal cations. The accuracy of this technique was verified by analyzing the metal sorption mechanism for the biomass of Rhizopus arrhizus fungus and diatomite, two dissimilar materials (organic and mineral, strong sorbent and weak sorbent) of a different order of cation exchange capacity. The problem of the initial electrochemical potential was addressed identifying the usefulness of a Na-sulfonic resin as a strong chelating agent applied before the beginning of sorption titration experiments so that the titration curves and the sorption uptake could be quantitatively compared. The resin stabilized the initial electrochemical potential to -405+/-5 mV corresponding to 2 micro gl(-1) of lead concentration in solution. The amounts of lead sorbed by R. arrhizus biomass and diatomite were 0.9 mmol g(-1) (C(e)=5.16 x 10(-2)mM) and 0.052 mmol g(-1) (C(e)=5.97 x 10(-2) mM), respectively. Lead sorption by the fungal biomass was pinpointed to at least two types of chemical active sites. The first type was distinguished by high reactivity and a low number of sites whereas the other was characterized by their higher number and lower reactivity.

  16. Graphical evaluation of complexometric titration curves.

    Science.gov (United States)

    Guinon, J L

    1985-04-01

    A graphical method, based on logarithmic concentration diagrams, for construction, without any calculations, of complexometric titration curves is examined. The titration curves obtained for different kinds of unidentate, bidentate and quadridentate ligands clearly show why only chelating ligands are usually used in titrimetric analysis. The method has also been applied to two practical cases where unidentate ligands are used: (a) the complexometric determination of mercury(II) with halides and (b) the determination of cyanide with silver, which involves both a complexation and a precipitation system; for this purpose construction of the diagrams for the HgCl(2)/HgCl(+)/Hg(2+) and Ag(CN)(2)(-)/AgCN/CN(-) systems is considered in detail.

  17. Kinetic Titration Series with Biolayer Interferometry

    Science.gov (United States)

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  18. Coulometrische titration von hypochloriten und chloraten.

    Science.gov (United States)

    Gründler, P; Holzapfel, H

    1970-03-01

    Hypochlorite was determined by direct coulometric titration with iron(II) in an acetate buffered solution. Chlorate was titrated with titanium(III) in 2M hydrochloric acid. Amperometric indication with one and two electrodes, respectively, was used. Mixtures of hypochlorites and chlorates, e.g., in industrial electrolytes, may be analysed. On a déterminé l'hypochlorite par titrage coulométrique direct avec le fer(II) dans une solution tamponnée à l'acétate. On a titré le chlorate avec le titane(III) en acide chlorhydrique 2M. On a utilisé l'indication ampérométrique une et deux électrodes respectivement. On peut analyser des mélanges d'hypochlorites et de chlorates, par exemple dans des électrolytes industriels.

  19. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  20. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    Science.gov (United States)

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  1. Spectrophotometric titration of zirconium in siliceous materials

    International Nuclear Information System (INIS)

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  2. Digital movie-based on automatic titrations.

    Science.gov (United States)

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Thermometric titration of acids in pyridine.

    Science.gov (United States)

    Vidal, R; Mukherjee, L M

    1974-04-01

    Thermometric titration of HClO(4), HI, HNO(3), HBr, picric acid o-nitrobenzoic acid, 2,4- and 2,5-dinitrophenol, acetic acid and benzoic acid have been attempted in pyridine as solvent, using 1,3-diphenylguanidine as the base. Except in the case of 2,5-dinitrophenol, acetic acid and benzoic acid, the results are, in general, reasonably satisfactory. The approximate molar heats of neutralization have been calculated.

  4. Determination of milligram amounts of neptunium by potentiometric titration

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Solntseva, L.F.

    1981-01-01

    Two procedures of potentiometric titration of about 1 mg Np are reported which are based on its oxidation to neptunium (6) with silver (2) oxide followed by titration with iron (2) to neptunium (5) in one case and to neptunium (4) in the alternative one. The error is not greater than 0.2% rel. Ten-fold uranium excess does not interfere. Up to 1% of plutonium relative to neptunium does not interfere in the case of the titration to neptunium (5). In the titration to neptunium (4), plutonium is titrated stoichiometrically [ru

  5. Potentiometric titrations in anhydrous acetic acid

    International Nuclear Information System (INIS)

    Le Port, L.

    1966-03-01

    The method used for studying anhydrous acetic acid is potentiometry with a glass electrode. We have in this way studied the titration of common inorganic acids (HClO 4 - HBr - H 2 SO 4 - HCl - HNO 3 - H 3 PO 4 ) and of some metallic salts. Furthermore we have shown that complex acids are formed between HCl and some metallic chlorides. An analysis of the titration curves for the inorganic acids against pyridinium chloride has made it possible to calculate a certain number of values for the dissociation pK of these acids and of the corresponding pyridinium salts. The titration of metallic perchlorates constitutes a method of studying the stability of acetates; we have thus been able to draw up a classification for some of these acetates. The metallic chlorides studied fall into two groups according to their behaviour in weak or strong acids. The differences have been explained on the basis of the role played by solvolysis. In the third part we have studied the acidic properties of mixtures of HCl with certain metallic chlorides. This work has demonstrated the existence, in certain cases, of acid complexes of the type (HCl) m MCl n . (author) [fr

  6. A new sensor for thermometric titrations.

    Science.gov (United States)

    Najib, Fadhil M; Zewar, Sardir; Abdulla, Ahmad M

    2007-01-15

    A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32micromol of HCl and 26.4micromol of H(3)BO(3)in a final 20ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK(1)=2.18, pK(2)=7.20 and pK(3)=12.32) as well as for a very weak acid of uncertain pK values H(3)BO(3) (pK(1)=9.20, pK(2)=12.7 and pK(3)=13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.

  7. Is automatic CPAP titration as effective as manual CPAP titration in OSAHS patients? A meta-analysis.

    Science.gov (United States)

    Gao, Weijie; Jin, Yinghui; Wang, Yan; Sun, Mei; Chen, Baoyuan; Zhou, Ning; Deng, Yuan

    2012-06-01

    It is costly and time-consuming to conduct the standard manual titration to identify an effective pressure before continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) patients. Automatic titration is cheaper and more easily available than manual titration. The purpose of this systematic review was to evaluate the effect of automatic titration in identifying a pressure and on the improvement of apnea/hyponea index (AHI) and somnolence, the change of sleep quality, and the acceptance and compliance of CPAP treatment, compared with the manual titration. A systematic search was made of the PubMed, EMBASE, Cochrane Library, SCI, China Academic Journals Full-text Databases, Chinese Biomedical Literature Database, Chinese Scientific Journals Databases and Chinese Medical Association Journals. Randomized controlled trials comparing automatic titration and manual titration were reviewed. Studies were pooled to yield odds ratios (OR) or mean differences (MD) with 95% confidence intervals (CI). Ten trials involving 849 patients met the inclusion criteria. It is hard to identify a trend in the pressures determined by either automatic or manual titration. Automatic titration can improve the AHI (MD = 0.03/h, 95% CI = -4.48 to 4.53) and Epworth sleepiness scale (SMD = -0.02, 95% CI = -0.34 to 0.31,) as effectively as the manual titration. There is no difference between sleep architecture under automatic titration or manual titration. The acceptance of CPAP treatment (OR = 0.96, 95% CI = 0.60 to 1.55) and the compliance with treatment (MD = -0.04, 95% CI = -0.17 to 0.10) after automatic titration is not different from manual titration. Automatic titration is as effective as standard manual titration in improving AHI, somnolence while maintaining sleep quality similar to the standard method. In addition, automatic titration has the same effect on the acceptance and compliance of CPAP treatment as manual titration. With the potential advantage

  8. Determination of neptunium by redox titration

    International Nuclear Information System (INIS)

    Godbole, A.G.; Patil, S.K.

    1979-01-01

    A simple and quick method for the potentiometric determination of neptunium on the 2 to 5 mg scale has been developed. It consists of oxidation to Np(VI) by AgO or fuming with HClO 4 , destruction of excess of AgO by sulphamic acid, reduction of Np(VI) to Np(IV) with a slight excess of standard Fe(II) in 2M H 2 SO 4 and potentiometric titration of the excess of Fe(II) with standard Ce(IV). The precision is +- 0.5%. (author)

  9. STUDY ON THE KINETICS OF POLYMERIZATION OF MMA BY COPPER(Ⅱ) CHELATING RESINS

    Institute of Scientific and Technical Information of China (English)

    WangHongzuo; JiangYuanzhang; 等

    1993-01-01

    The polymerization of MMA initiated by copper(Ⅱ) chelating resins/CCl4 system was studied.From the kinetic data,the kinetic equation of polymerization can be expressed as Rp=Ke-56400/RT[MMA]1.57[CCl4]m[RESIN-Cu]0.18 where m:3-4.5,when[CCl4] 0.1-6.93M.The free radical polymerization mechanism is proposed.The primary radicals are formed by the process of complexation-chlorine transformation among the copper(Ⅱ) chelating resin,CCl4 and methacrylate.

  10. Improving medication titration in heart failure by embedding a structured medication titration plan.

    Science.gov (United States)

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (pplan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Radiation curable epoxy resin

    International Nuclear Information System (INIS)

    Najvar, D.J.

    1978-01-01

    A carboxyl containing polymer is either prepared in the presence of a polyepoxide or reacted with a polyepoxide. The polymer has sufficient acid groups to react with only about 1 to 10 percent of the epoxide (oxirane) groups. The remaining epoxide groups are reacted with an unsaturated monocarboxylic acid such as acrylic or methacrylic acid to form a radiation curable resin

  12. Resin impregnation process for producing a resin-fiber composite

    Science.gov (United States)

    Palmer, Raymond J. (Inventor); Moore, William E. (Inventor)

    1994-01-01

    Process for vacuum impregnation of a dry fiber reinforcement with a curable resin to produce a resin-fiber composite, by drawing a vacuum to permit flow of curable liquid resin into and through a fiber reinforcement to impregnate same and curing the resin-impregnated fiber reinforcement at a sufficient temperature and pressure to effect final curing. Both vacuum and positive pressure, e.g. autoclave pressure, are applied to the dry fiber reinforcement prior to application of heat and prior to any resin flow to compact the dry fiber reinforcement, and produce a resin-fiber composite of reduced weight, thickness and resin content, and improved mechanical properties. Preferably both a vacuum and positive pressure, e.g. autoclave pressure, are also applied during final curing.

  13. Cellular impedance measurement as a new tool for poxvirus titration, antibody neutralization testing and evaluation of antiviral substances

    International Nuclear Information System (INIS)

    Witkowski, Peter T.; Schuenadel, Livia; Wiethaus, Julia; Bourquain, Daniel R.; Kurth, Andreas; Nitsche, Andreas

    2010-01-01

    Research highlights: → Real-time data acquisition by RT-CES requires low operative effort. → Time to result is reduced by using RT-CES instead of conventional methods. → RT-CES enables quantification of virus titers in unknown samples. → RT-CES is a useful tool for high-throughput characterization of antiviral agents. → An RT-CES-based virus neutralization test was established. -- Abstract: Impedance-based biosensing known as real-time cell electronic sensing (RT-CES) belongs to an emerging technology for analyzing the status of cells in vitro. In the present study protocols were developed for an RT-CES-based system (xCELLigence TM , Roche Applied Science, ACEA Biosciences Inc.) to supplement conventional techniques in pox virology. First, proliferation of cells susceptible to orthopoxviruses was monitored. For virus titration cells were infected with vaccinia virus and cell status, represented by the dimensionless impedance-based cell index (CI), was monitored. A virus-dose dependent decrease in electrical impedance could be shown. Calculation of calibration curves at a suitable CI covering a dynamic range of 4 log enabled the quantification of virus titers in unknown samples. Similarly, antiviral effects could be determined as shown for anti-poxviral agents ST-246 and Cidofovir. Published values for the in vitro concentration that inhibited virus replication by 50% (IC 50 ) could be confirmed while cytotoxicity in effective concentrations was excluded in long-term incubation experiments. Finally, an RT-CES-based virus neutralization test was established. Various poxvirus-specific antibodies were examined for their neutralizing activity and a calculation mode for the neutralizing antibody titer was introduced. In summary, the presented RT-CES-based methods outmatch end-point assays by observing the cell population throughout the entire experiment while workload and time to result are reduced.

  14. Up-titration of allopurinol in patients with gout.

    Science.gov (United States)

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Automated titration method for use on blended asphalts

    Science.gov (United States)

    Pauli, Adam T [Cheyenne, WY; Robertson, Raymond E [Laramie, WY; Branthaver, Jan F [Chatham, IL; Schabron, John F [Laramie, WY

    2012-08-07

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  16. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  17. Titration in the treatment of the more troubled patient.

    Science.gov (United States)

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  18. A computer controlled potentiometric titrator for quantitative determination of uranium

    International Nuclear Information System (INIS)

    Verdingh, V.; Michiels, A.

    1988-01-01

    The modified Davies and Gray methods is frequently used for the potentiometric titration of uranium. It is based upon the reduction of U(VI) to U(IV) with a reductant (e.g. Fe ++ ) followed by a selective oxidation of the excess of reductant and subsequent titration of U(IV) with potassium dichromate (K 2 Cr 2 O 7 ). Interference from other elements is low, but the method is rather cumbersome due to the number of reactants to be added before the titration is started. The timing of these additions also plays a role. In order to render the titration less dependent on human factors and with the aim of reaching high reproducibility, a computer controlled system has been designed and set-up. Reagents are added by five computer controlled burettes. A program allows the choice of volumes and waiting times, and commands the start of the final titration which is followed by the microprocessor of the automatic potentiometric titrator. In this way a routine uranium titration can be completed in about twelve minutes. Reproducibilities of the order of ±15% are achievable in routine operation. For high precision work, the titrator is used as an end-point detector. Titrant is added manually by mass, so as to react with > 99% of the uranium. The residual uranium is then titrated automatically by colume with diluted titrant. The precision can be improved by a factor of approximately ten. (orig.)

  19. The acid-base titration of montmorillonite

    Science.gov (United States)

    Bourg, I. C.; Sposito, G.; Bourg, A. C.

    2003-12-01

    Proton binding to clay minerals plays an important role in the chemical reactivity of soils (e.g., acidification, retention of nutrients or pollutants). If should also affect the performance of clay barriers for waste disposal. The surface acidity of clay minerals is commonly modelled empirically by assuming generic amphoteric surface sites (>SOH) on a flat surface, with fitted site densities and acidity constant. Current advances in experimental methods (notably spectroscopy) are rapidly improving our understanding of the structure and reactivity of the surface of clay minerals (arrangement of the particles, nature of the reactive surface sites, adsorption mechanisms). These developments are motivated by the difficulty of modelling the surface chemistry of mineral surfaces at the macro-scale (e.g., adsorption or titration) without a detailed (molecular-scale) picture of the mechanisms, and should be progressively incorporated into surface complexation models. In this view, we have combined recent estimates of montmorillonite surface properties (surface site density and structure, edge surface area, surface electrostatic potential) with surface site acidities obtained from the titration of alpha-Al2O3 and SiO2, and a novel method of accounting for the unknown initial net proton surface charge of the solid. The model predictions were compared to experimental titrations of SWy-1 montmorillonite and purified MX-80 bentonite in 0.1-0.5 mol/L NaClO4 and 0.005-0.5 mol/L NaNO3 background electrolytes, respectively. Most of the experimental data were appropriately described by the model after we adjusted a single parameter (silanol sites on the surface of montmorillonite were made to be slightly more acidic than those of silica). At low ionic strength and acidic pH the model underestimated the buffering capacity of the montmorillonite, perhaps due to clay swelling or to the interlayer adsorption of dissolved aluminum. The agreement between our model and the experimental

  20. On the theory of thermometric titration.

    Science.gov (United States)

    Piloyan, G O; Dolinina, Y V

    1974-09-01

    The general equation defining the change in solution temperature DeltaT during a thermometric titration is DeltaT = T - T(0) = - AV 1 + BV where A and B are constants, V is the volume of titrant used to produce temperature T, and T(0) is the initial temperature. There is a linear relation between the inverse values of DeltaT and V: 1 Delta T = - a V - b where a = 1/A and b = B/A, both a and b being constants. A linear relation between DeltaT and V is usually a special case of this general relation, and is valid only over a narrow range of V. Graphs of 1/DeltaTvs. 1/V are more suitable for practical calculations than the usual graphs of DeltaTvs. V.

  1. Students' integration of multiple representations in a titration experiment

    Science.gov (United States)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  2. Analysis of the Purity of Cetrimide by Titrations

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Nielsen, Hans/Boye

    2006-01-01

    . Titration by perchloric acid showed a 99.69 ± 0.05 % purity of cetrimide and titration by silver nitrate showed a 99.85% ± 0.05 % purity while the traditional assay method predicted a purity of only 97.1 ± 0.4. It was found that the discrepancy could be identified as differences in selectivity during...

  3. A Closer Look at Acid-Base Olfactory Titrations

    Science.gov (United States)

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  4. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    Science.gov (United States)

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  5. New applications of corrosion measurements by titration (CMT)

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers

    1998-01-01

    . It is shown that when aluminium dissolves in alkali, CMT measurements can also be applied, but in this case requiring titration with alkali. Titration with alkali is also required in a special situation, where corrosion of nickel in an acid solution and subsequent formation of a nickel complex results...

  6. The coulometric titration of acids and bases in dimethylsulfoxide media

    NARCIS (Netherlands)

    Bos, M.; IJpma, S.T.; Dahmen, E.A.M.F.

    1976-01-01

    The coulometric titration of 20–200 μeq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current

  7. Study on the Image Quality Comparison between in Digital RT and Film RT

    International Nuclear Information System (INIS)

    Park, Sang Ki; Ahn, Yean Shik; Gil, Doo Song

    2011-01-01

    Conventional film radiographic test has been generally and widely used in the inspection on the weldment for quality assurance. On the other hand, since the analog RT is well known for typical time and cost consuming method with complex process of inspection, the industry has researched various ways how to improve radiographic test technology. In this study, we verified the fact that digital RT provides a lot more benefit in effectively detecting defects, ever film details, through digital processing of image enhancement, compared to film RT. As a result, we reached conclusion that digital RT is positively able to replace the film RT in industry in part or in whole

  8. Embedding in thermosetting resins

    International Nuclear Information System (INIS)

    Buzonniere, A. de

    1985-01-01

    Medium activity waste coming either from nuclear power plants in operation such as evaporator concentrates, spent resins, filter cartridges or the dismantling of installations are embedded in order to obtain a product suitable for long term disposal. Embedding in thermosetting resins (polyester or epoxy) is one among currently used techniques; it is being developed by the CEA (Commissariat a l'Energie Atomique) and Technicatome (subsidiary of CEA and EDF). The process is easy to operate and yields excellent results particularly as far as volume reduction and radioelement containment (cesium particularly) are concerned. The process has already been in operation in four stationary plants for several years. Extension of the process to mobile units has been completed by Technicatome in collaboration with the CEA [fr

  9. Node Ranking Tool - NoRT

    Science.gov (United States)

    2018-03-23

    NoRT) that was developed as part of the Applied Network Science 6.2 base program work unit at NRL, Code 5580. We explain the theory of NoRT and how...to use it. 23-03-2018 Memorandum Report TOPSIS, Social Network, Sensor Network, Centrality, Diffusion, Disease, Virus, Expectation , Pandemic...base program work unit at NRL. We explain the theory of NoRT and how to use it. Index Terms TOPSIS, Social Network, Sensor Network, Centrality, Diffusion

  10. Paramagnetic epoxy resin

    Directory of Open Access Journals (Sweden)

    E. C. Vazquez Barreiro

    2017-01-01

    Full Text Available This work illustrates that macrocycles can be used as crosslinking agents for curing epoxy resins, provided that they have appropriate organic functionalities. As macrocycles can complex metal ions in their structure, this curing reaction allows for the introduction of that metal ion into the resin network. As a result, some characteristic physical properties of the metallomacrocycle could be transferred to the new material. The bisphenol A diglycidyl ether (BADGE, n = 0 and hemin (a protoporphyrin IX containing the Fe(III ion, and an additional chloride ligand have been chosen. The new material has been characterized by differential scanning calorimetry (DSC, thermogravimetric analysis (TGA, Fourier Transform Infrared (FT-IR, Nuclear Magnetic Resonance (NMR, Transmission Electron Microscopy (TEM, and magnetic susceptibility measurements. Fe(III remains in the high-spin state during the curing process and, consequently, the final material exhibits the magnetic characteristics of hemin. The loss of the chlorine atom ligand during the cure of the resin allows that Fe(III can act as Lewis acid, catalyzing the crosslinking reactions. At high BADGE n = 0/hemin ratios, the formation of ether and ester bonds occurs simultaneously during the process.

  11. A simplified method for active-site titration of lipases immobilised on hydrophobic supports.

    Science.gov (United States)

    Nalder, Tim D; Kurtovic, Ivan; Barrow, Colin J; Marshall, Susan N

    2018-06-01

    The aim of this work was to develop a simple and accurate protocol to measure the functional active site concentration of lipases immobilised on highly hydrophobic supports. We used the potent lipase inhibitor methyl 4-methylumbelliferyl hexylphosphonate to titrate the active sites of Candida rugosa lipase (CrL) bound to three highly hydrophobic supports: octadecyl methacrylate (C18), divinylbenzene crosslinked methacrylate (DVB) and styrene. The method uses correction curves to take into account the binding of the fluorophore (4-methylumbelliferone, 4-MU) by the support materials. We showed that the uptake of the detection agent by the three supports is not linear relative to the weight of the resin, and that the uptake occurs in an equilibrium that is independent of the total fluorophore concentration. Furthermore, the percentage of bound fluorophore varied among the supports, with 50 mg of C18 and styrene resins binding approximately 64 and 94%, respectively. When the uptake of 4-MU was calculated and corrected for, the total 4-MU released via inhibition (i.e. the concentration of functional lipase active sites) could be determined via a linear relationship between immobilised lipase weight and total inhibition. It was found that the functional active site concentration of immobilised CrL varied greatly among different hydrophobic supports, with 56% for C18, compared with 14% for DVB. The described method is a simple and robust approach to measuring functional active site concentration in immobilised lipase samples. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. System for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  13. A generalized approach for the calculation and automation of potentiometric titrations Part 1. Acid-Base Titrations

    NARCIS (Netherlands)

    Stur, J.; Bos, M.; van der Linden, W.E.

    1984-01-01

    Fast and accurate calculation procedures for pH and redox potentials are required for optimum control of automatic titrations. The procedure suggested is based on a three-dimensional titration curve V = f(pH, redox potential). All possible interactions between species in the solution, e.g., changes

  14. rt: Berliner Messe / Rob Cowan

    Index Scriptorium Estoniae

    Cowan, Rob

    1998-01-01

    Uuest heliplaadist "Pärt: Berliner Messe. The Beatitudes. Annum per Annum. Magnificat. Seven Magnificat Antiphons. De profundis. Polyphony / Steven Layton with Andrew Lucas" Hyperion CDA66960 (74 minutes:DDD)

  15. Arvo Pärt. Litany / Peter Korfmacher

    Index Scriptorium Estoniae

    Korfmacher, Peter

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo. Litany; Psalom; Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste"; Lithuanian Chamber Orchestra, Saulius Sondeckis. ECM 1592/449 810-2

  16. rt: Fratres / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1995-01-01

    Uuest heliplaadist "Pärt: Fratres (seven versions). Festina Lente. Cantus in Memory of Benjamin Britten. Summa. Peter Manning (vn.), France Springuel (vc.), Mireille Gleizes (pf.), I Fiamminghi. Telare CD CD80387 (79 minutes)

  17. Synthesis, characterization and applications of a new cation exchanger tamarind sulphonic acid (TSA) resin.

    Science.gov (United States)

    Singh, A V; Sharma, Naresh Kumar; Rathore, Abhay S

    2012-01-01

    A new composite cation exchanger, tamarind sulphonic acid (TSA) resin has been synthesized. The chemically modified TSA ion exchange resin has been used for the removal and preconcentration of Zn2+, Cd2+, Fe2+, Co2+ and Cu2+ ions in aqueous solution and effluent from the Laxmi steel plant in Jodhpur, India. This type of composite represents a new class of hybrid ion exchangers with good ion exchange capacity, stability, reproducibility and selectivity for toxic metal ions found in effluent from the steel industry. The characterization of the resin was carried out by determining the ion-exchange capacity, elemental analysis, pH titration, Fourier transform infrared spectra and thermal analysis. The distribution coefficients (K(d)) of toxic metal ions were determined in a reference aqueous solution and the steel plant effluent at different pH values; the absorbency of different metal ions on the TSA resin was studied for up to 10 cycles. The adsorption of different metal ions on TSA resin follows the order: Co2+ > Cu2+ > Zn2+ > Fe2+ > Cd2+. The ion exchange capacity of TSA resin is 2.87%.

  18. Contact allergy to epoxy resin

    DEFF Research Database (Denmark)

    Bangsgaard, Nannie; Thyssen, Jacob Pontoppidan; Menné, Torkil

    2012-01-01

    Background. Epoxy resin monomers are strong skin sensitizers that are widely used in industrial sectors. In Denmark, the law stipulates that workers must undergo a course on safe handling of epoxy resins prior to occupational exposure, but the effectiveness of this initiative is largely unknown...... in an educational programme. Conclusion. The 1% prevalence of epoxy resin contact allergy is equivalent to reports from other countries. The high occurrence of epoxy resin exposure at work, and the limited use of protective measures, indicate that reinforcement of the law is required....

  19. Titration and hysteresis in epigenetic chromatin silencing

    International Nuclear Information System (INIS)

    Dayarian, Adel; Sengupta, Anirvan M

    2013-01-01

    Epigenetic mechanisms of silencing via heritable chromatin modifications play a major role in gene regulation and cell fate specification. We consider a model of epigenetic chromatin silencing in budding yeast and study the bifurcation diagram and characterize the bistable and the monostable regimes. The main focus of this paper is to examine how the perturbations altering the activity of histone modifying enzymes affect the epigenetic states. We analyze the implications of having the total number of silencing proteins, given by the sum of proteins bound to the nucleosomes and the ones available in the ambient, to be constant. This constraint couples different regions of chromatin through the shared reservoir of ambient silencing proteins. We show that the response of the system to perturbations depends dramatically on the titration effect caused by the above constraint. In particular, for a certain range of overall abundance of silencing proteins, the hysteresis loop changes qualitatively with certain jump replaced by continuous merger of different states. In addition, we find a nonmonotonic dependence of gene expression on the rate of histone deacetylation activity of Sir2. We discuss how these qualitative predictions of our model could be compared with experimental studies of the yeast system under anti-silencing drugs. (paper)

  20. Resin regenerating device in condensate desalting system

    International Nuclear Information System (INIS)

    Sato, Yoshiaki; Igarashi, Hiroo; Oosumi, Katsumi; Nishimura, Yusaku; Ebara, Katsuya; Shindo, Norikazu.

    1984-01-01

    Purpose: To improve the accuracy in the separation of anionic and cationic exchange resins. Constitution: Resins transferred from a condensate desalting column are charged in a cationic exchange resin column. The temperature of water for separating and transferring the resins is measured by a temperature detector disposed in a purified water injection line, and water is adjusted to a suitable flow rate for the separation and transfer of the resins by an automatic flow rate control valve, and then is injected. The resins are separated into cationic exchange resins and anionic exchange resins, in which only the anionic exchange resins are transferred, through an anionic exchange transfer line, into an anionic exchange resin column. By controlling the flow rate depending on the temperature of the injected water, the developing rate of the resin layer is made constant to enable separation and transfer of the resins at high accuracy. (Seki, T.)

  1. Novel titration method for surface-functionalised silica

    Energy Technology Data Exchange (ETDEWEB)

    Hofen, Kai; Weber, Siegfried [Department of Biotechnology, University of Applied Sciences, Mannheim (Germany); Chan, Chiu Ping Candace [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia); Majewski, Peter, E-mail: peter.majewski@unisa.edu.au [School of Advanced Manufacturing and Mechanical Engineering, Mawson Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes 5095 (Australia)

    2011-01-15

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH{sub 2}-, SO{sub 3}H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  2. Novel titration method for surface-functionalised silica

    International Nuclear Information System (INIS)

    Hofen, Kai; Weber, Siegfried; Chan, Chiu Ping Candace; Majewski, Peter

    2011-01-01

    This paper describes three inexpensive and fast analytical methods to characterise grafted particle surfaces. The reaction of silica with (3-aminopropyl)triethoxysilane, (3-mercaptopropyl)trimethoxysilane and N-(phosphonomethyl)iminodiacetic acid hydrate, respectively, leads to NH 2 -, SO 3 H- or COOH-functionalised silica, which were characterised by X-ray photoelectron spectrometry and titration in nonaqueous media as well as with two titration methods in a water-based environment. In the work presented, factors influencing the titrations are pointed out and solutions are presented to overcome these limiting factors are shown.

  3. The fluorimetric titration of zirconium in the ppm-range

    International Nuclear Information System (INIS)

    Linden, W.E. von der; Boef, G. den; Ozinga, W.

    1976-01-01

    A fluorimetric titration of zirconium(IV) with EDTA is proposed. The fluorescence intensity of the zirconium-morin complex is used to indicate the end-point. More than twenty other cations were investigated and it was found that they did not interfere, neither did common anions. Mercury(II) can only be tolerated in amount not exceeding that of zirconium. Bismuth(III) interferes and hafnium(IV0 is titrated together with zirconium. The relative standard deviation of the titration of 10ml of a solution containing 1 ppm of zirconium does not exceed 1.5%

  4. Determination of boron as boric acid by automatic potentiometric titration

    International Nuclear Information System (INIS)

    Midgley, D.

    1988-06-01

    Boron in PWR primary coolant and related waters may be determined as boric acid by titration with sodium hydroxide, using a glass electrode as a pH indicator. With a modern automatic titrator, the analysis is quick, convenient, accurate and precise. In the titration of 8 mg B (e.g. 4 ml of 2000 mg 1 -1 solution), no significant bias was observed and relative standard deviations were about 0.25%. With 0.8 g B, a bias of about 2% appears, although this could be reduced by restandardizing the titrant, but the relative standard deviation was still -1 B, depending on the stage of the fuel cycle. (author)

  5. The Potentiometric Titration of Filtrates from the Bachmann Process

    Science.gov (United States)

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  6. Microshear bond strength of preheated silorane- and methacrylate-based composite resins to dentin.

    Science.gov (United States)

    Demirbuga, Sezer; Ucar, Faruk Izzet; Cayabatmaz, Muhammed; Zorba, Yahya Orcun; Cantekin, Kenan; Topçuoğlu, Hüseyin Sinan; Kilinc, Halil Ibrahim

    2016-01-01

    The aim of this study was to investigate the effect of preheating on microshear bond strength (MSBS) of silorane and methacrylate-based composite resins to human dentin. The teeth were randomly divided into three main groups: (1) composite resins were heated upto 68 °C; (2) cooled to 4 °C; and (3) control [room temperature (RT)]. Each group was then randomly subdivided into four subgroups according to adhesive system used [Solobond M (Voco), All Bond SE (Bisco), Clearfil SE Bond (CSE) (Kuraray), Silorane adhesive system (SAS) (3M ESPE)]. Resin composite cylinders were formed (0.9 mm diameter × 0.7 mm length) and MSBS of each specimen was tested. The preheated groups exhibited the highest MSBS (p composite resins may be an alternative way to increase the MSBS of composites on dentin. © Wiley Periodicals, Inc.

  7. Properties of the Carboxylate ion exchange resins

    International Nuclear Information System (INIS)

    Allard, Bert; Dario, Maarten; Boren, Hans; Torstenfelt, Boerje; Puigdomenech, Ignasi; Johansson, Claes

    2002-09-01

    Weakly acidic, carboxylic resin has been selected, together with strong base anion resins, for water purification at the Forsmark 1 and 2 reactors. For the strong (but not the weak) ion exchange resin the Nuclear Power Inspectorate has given permission to dispose the spent resins in the SFR 1 (the Final Repository for Radioactive Operational Waste). This report gives a review of the carboxylic resins and comes to the conclusion that the resins are very stable and that there should not exist any risks for increased leaching of radionuclides from SFR 1 if these resins are disposed (compared to the strong resins)

  8. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  9. Chemoviscosity modeling for thermosetting resins

    Science.gov (United States)

    Tiwari, S. N.; Hou, T. H.; Bai, J. M.

    1985-01-01

    A chemoviscosity model, which describes viscosity rise profiles accurately under various cure cycles, and correlates viscosity data to the changes of physical properties associated with structural transformations of the thermosetting resin system during cure, was established. Work completed on chemoviscosity modeling for thermosetting resins is reported.

  10. Cure shrinkage in casting resins

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J. Brock [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    A method is described whereby the shrinkage of a casting resin can be determined. Values for the shrinkage of several resin systems in frequent use by Sandia have been measured. A discussion of possible methods for determining the stresses generated by cure shrinkage and thermal contraction is also included.

  11. Simple home-made sensors for potentiometric titrations

    International Nuclear Information System (INIS)

    Selig, W.

    1982-04-01

    A sensor for potentiometric titrations was prepared by coating a spectroscopic graphite rod with a solution of poly(vinyl chloride) and dioctyphthalate in tetrahydrofuran. The reference electrode was an Ag/AgCl single-junction electrode. The sensor was used in precipitation, acid-base, compleximetric, and redox titrations. Preparation of the coated-graphite sensor is simple and rapid. Moreover, it is quite inexpensive. A limitation is its applicability in aqueous media only, because organic solvents will dissolve the membrane. Various uncoated types of graphite have also been investigated as sensors, particularly in two applications of interest in the analysis of propellants: the titration of nitroform and perchlorate. Obviously, these sensors can be used also in nonaqueous, or partially nonaqueous media. These sensors may also find use in the potentiometric titration of fluoride vs La(III) or Th

  12. Spectrophotometric titration of sulfates in the presence of zirconium

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  13. Coulometric titration of niobium in 1F sulfuric acid

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1975-01-01

    A coulometric titration at constant current has been devised for Nb in 1F sulfuric acid. The titration was based on the oxidation of Nb(III) to Nb(V) by Fe(III) electrogenerated at a graphite anode. Both potentiometric and amperometric end points were used. The Nb(V) was prior reduced at a mercury cathode by exhaustive electrolysis at a current density of 15 ma/mc 2 for at least 10 hr. Ta,V,Ti and a working platinum anode interfered, but the separation of the potentials of Nb(V)/Nb(III) and Ti(IV)/Ti(III) permitted the titration of first Nb and then Ti. The average error for the titration of 0.30 to 13.00 mg of niobium in 100 ml of 1F sulfuric acid was + 0.57%. (author)

  14. Coulometric titration of niobium in EDTA complexing solution

    International Nuclear Information System (INIS)

    Pannu, S.S.

    1976-01-01

    Constant current coulometry of Nb in EDTA was studied employing both potentiometric and amperometric end-point techniques. The titrations were based on the oxidation of Nb(IV)-EDTA with electrogenerated Fe(III) at a graphite anode. The rate of disproportionation of Nb(IV)-EDTA was found to be slow enough not to effect the accuracy sought for the titration. The coulometric titration of Nb in EDTA was found to be more accurate than in 1F sulfuric acid. The mean error in the titrations of 4.76 to 19.65 of Nb in a volume of about 100 ml of 0.02 to 0.04F EDTA was 0.13%. It was found that Ta may be tolerated to a ratio of 1:4, Ta:Nb, in a solution containing 13 mg of Nb. (author)

  15. Green chemistry volumetric titration kit for pharmaceutical formulations: Econoburette

    Directory of Open Access Journals (Sweden)

    Man Singh

    2009-08-01

    Full Text Available Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR, Ministry of Small Scale Industries, Government of India, developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and conical flask by inbuilt bulb. A step of pipetting of stock solution by mouth is deleted. It is used to allow solution exposure to user’s body. This risk is removed and even volatile and toxic solutions are titrated with full proof safety. Econoburette minimizes use of materials and time by 90 % and prevent discharge of polluting effluent to environment. Few acid and base samples are titrated and an analysis of experimental expenditure is described in the papers.

  16. Potentiometric titration of free acid in uranium solutions

    International Nuclear Information System (INIS)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors' researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors' researches are appended. (author). 26 refs., 54 figs

  17. Potentiometric titration of free acid in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors` researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors` researches are appended. (author). 26 refs., 54 figs.

  18. A Titration Technique for Demonstrating a Magma Replenishment Model.

    Science.gov (United States)

    Hodder, A. P. W.

    1983-01-01

    Conductiometric titrations can be used to simulate subduction-setting volcanism. Suggestions are made as to the use of this technique in teaching volcanic mechanisms and geochemical indications of tectonic settings. (JN)

  19. A microcomputer-controlled system for titration analysis

    NARCIS (Netherlands)

    Boelema, Gerrit Jan

    1982-01-01

    This thesis deals with the results of the implementation of microprocessor technology in automatic titration equipment to obtain a versatile system for pharmaceutical, chemical analytical and optimization research purposes. ... Zie: Summary

  20. Carbon dioxide titration method for soil respiration measurements

    OpenAIRE

    Martín Rubio, Luis

    2017-01-01

    This thesis was commissioned by Tampere University of Applied Sciences, which was interested in studying and developing a titration measurement method for soil respiration and biodegradability. Some experiments were carried out measuring soil respiration for testing the method and others adding some biodegradable material like polylactic acid compressed material and 100% biodegradable plastic bags to test its biodegradability and the possibility to measure it via titration. The thesi...

  1. A fully automatic system for acid-base coulometric titrations

    OpenAIRE

    Cladera, A.; Caro, A.; Estela, J. M.; Cerdà, V.

    1990-01-01

    An automatic system for acid-base titrations by electrogeneration of H+ and OH- ions, with potentiometric end-point detection, was developed. The system includes a PC-compatible computer for instrumental control, data acquisition and processing, which allows up to 13 samples to be analysed sequentially with no human intervention. The system performance was tested on the titration of standard solutions, which it carried out with low errors and RSD. It was subsequently applied to the analysis o...

  2. Amperometric titration of indium with edta solution in propanol

    International Nuclear Information System (INIS)

    Gevorgyan, A.M.; Talipov, Sh.T.; Khadeev, V.A.; Kostylev, V.S.; Khadeeva, L.A.

    1980-01-01

    Optimum conditions have been chosen for titration of indium with EDTA solution in anhydrous propanol and its mixtures with some aprotic solvents using amperometric and point detection. A procedure is suggested of determining indium microcontents in the presence of large amounts of other elements. The procedure is based on its extraction preseparation followed by direct titration in the extract with a standard EDTA solution [ru

  3. MINIX4RT: Real-Time Semaphores

    OpenAIRE

    Pessolani, Pablo Andrés

    2007-01-01

    MINIX4RT es una extensión del conocido Sistema Operativo MINIX que incorpora servicios de Tiempo Real Estricto en un nuevo microkernel pero manteniendo compatibilidad con las versiones anteriores del MINIX estándar. Los semáforos son el mecanismo primitivo para la sincronización y exclusion mutua en varios sistemas operativos, pero MINIX no brinda esa facilidad. Se adicionaron semáforos a MINIX4RT y, como éste es un Sistema Operativo de Tiempo Real, deben reunir ciertos requisitos de procesam...

  4. Artist - analytical RT inspection simulation tool

    International Nuclear Information System (INIS)

    Bellon, C.; Jaenisch, G.R.

    2007-01-01

    The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the prediction of its reliability, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the integrated project FilmFree the radiographic testing (RT) simulation software developed by BAM is being further developed to meet practical requirements for inspection planning in digital industrial radiology. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, railways and others. (authors)

  5. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    Science.gov (United States)

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  6. Gran method for end point anticipation in monosegmented flow titration

    Directory of Open Access Journals (Sweden)

    Aquino Emerson V

    2004-01-01

    Full Text Available An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 mL of sample and about the same volume of titrant (AgNO3 solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision (relative standard deviation of ten replicates are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.

  7. Detecting Levels of Polyquaternium-10 (PQ-10) via Potentiometric Titration with Dextran Sulphate and Monitoring the Equivalence Point with a Polymeric Membrane-Based Polyion Sensor.

    Science.gov (United States)

    Ferguson, Stephen A; Wang, Xuewei; Meyerhoff, Mark E

    2016-08-07

    Polymeric quaternary ammonium salts (polyquaterniums) have found increasing use in industrial and cosmetic applications in recent years. More specifically, polyquaternium-10 (PQ-10) is routinely used in cosmetic applications as a conditioner in personal care product formulations. Herein, we demonstrate the use of potentiometric polyion-sensitive polymeric membrane-based electrodes to quantify PQ-10 levels. Mixtures containing both PQ-10 and sodium lauryl sulfate (SLS) are used as model samples to illustrate this new method. SLS is often present in cosmetic samples that contain PQ-10 (e.g., shampoos, etc.) and this surfactant species interferes with the polyion sensor detection chemistry. However, it is shown here that SLS can be readily separated from the PQ-10/SLS mixture by use of an anion-exchange resin and that the PQ-10 can then be titrated with dextran sulphate (DS). This titration is monitored by potentiometric polyanion sensors to provide equivalence points that are directly proportional to PQ-10 concentrations.

  8. rt, Arvo. Fratres / Rainer Wagner

    Index Scriptorium Estoniae

    Wagner, Rainer

    1995-01-01

    Uuest heliplaadist "Pärt, Arvo. Fratres, Cantus (in Memory of Benjamin Britten), summa, Festina Lente; Peter Manning, France Springuel, Mireille Gleizes, Huub Righarts, I Fiamminghi, Rudolf Werthen" (AD: 1994) Telarc/in-akustik CD 80 387 (WD: 79'00")

  9. rt, Arvo: "Litany" / Barry Witherden

    Index Scriptorium Estoniae

    Witherden, Barry

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: "Litany". Litany. Psalom. Trisagion. The Hilliard Ensemble, Tallinn Chamber Orchestra, Estonian Philharmonic Chamber Orchestra, Estonian Philharmonic Chamber Choir, Tõnu Kaljuste. Orchestre de chambre de Lituanie, Saulius Sondeckis". ECM New Series ECM 1592, distribution Polygram 449 810-2 (CD:158F)

  10. Forført af hjernen?

    DEFF Research Database (Denmark)

    Lieberoth, Andreas

    2013-01-01

    Blandingen af offentlig interesse, gode mediehistorier og smarte sælgere har ført til sejlivede neuromyter, der ikke bare distraherer almindelige mennesker, men også fører til udbredte misforståelser blandt professionelle som lærere og plejepersonale. I bedste fald leder neuromyter til spild af t...

  11. rt, Arvo: "Litany" / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: "Litany". Litany. Psalom. Trisagion. The Hilliard Ensemble, Orchestre de chambre de Tallinn, Choeur de chambre Philharmonique d'Estonie, Tõnu Kaljuste. Orchestre de chambre de Lituanie, Saulius Sondeckis. ECM New Series ECM 1592, distribution Polygram 449 810-2 (CD:158F)

  12. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  13. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  14. Effects of blood contamination on resin-resin bond strength.

    Science.gov (United States)

    Eiriksson, Sigurdur O; Pereira, Patricia N R; Swift, Edward J; Heymann, Harald O; Sigurdsson, Asgeir

    2004-02-01

    Incremental placement and curing of resin composites has been recommended. However, this requires longer operating time, and therefore, increased risk of contamination. The purpose of this study was to evaluate the effects of blood contamination on microtensile bond strengths (microTBS) between resin interfaces and to determine the best decontamination method to re-establish the original resin-resin bond strength. The top surfaces of 64, 4-mm composite blocks (Z-250, Renew, APX, Pertac II) were untreated as the control, or were treated as follows: blood applied and dried on the surface (Treatment 1), blood applied, rinsed, dried (Treatment 2), blood applied, rinsed, and an adhesive applied (Single Bond, One-Step, Clearfil SE, Prompt L-Pop) (Treatment 3). Fresh composite was applied and light-cured in 2-mm increments. After 24 h storage in water, the specimens were sectioned into 0.7-mm thick slabs, trimmed to a cross-sectional area of 1 mm(2), and loaded to failure at a crosshead speed of 1 mm/min using an Instron universal testing machine. Data were analyzed using two-way ANOVA and Fisher's PLSD test (pcontamination resulted in resin-resin bond strengths of only 1.0-13.1 MPa. Rinsing raised bond strengths to over 40 MPa for each material. Use of an adhesive further increased bond strengths except for Pertac II. Rinsing blood from contaminated surfaces increases the resin-resin bond strength significantly and the application of an appropriate adhesive increases the bond strength to control levels.

  15. Rapid clozapine titration in treatment-refractory bipolar disorder.

    Science.gov (United States)

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    Science.gov (United States)

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  17. Bending characteristics of resin concretes

    Directory of Open Access Journals (Sweden)

    Ribeiro Maria Cristina Santos

    2003-01-01

    Full Text Available In this research work the influence of composition and curing conditions in bending strength of polyester and epoxy concrete is analyzed. Various mixtures of resin and aggregates were considered in view of an optimal combination. The Taguchi methodology was applied in order to reduce the number of tests, and in order to evaluate the influence of various parameters in concrete properties. This methodology is very useful for the planning of experiments. Test results, analyzed by this methodology, shown that the most significant factors affecting bending strength properties of resin concretes are the type of resin, resin content and charge content. An optimal formulation leading to a maximum bending strength was achieved in terms of material parameters.

  18. Mechanism for transporting used resin

    International Nuclear Information System (INIS)

    Sugimoto, Yoshikazu; Yusa, Hideo; Kamiya, Kunio.

    1975-01-01

    Object: In the operation of a light water reactor type atomic power plant, to permit transport and reuse of used ion exchange resin used for the filtering or cleaning of cooling water or the desalting of radioactive exhaust liquid through an ejector. Structure: Used ion exchange resin within a desalter having high radioactivity is withdrawn through the action of an ejector and led to a solid-liquid separator for separation into used resin and water. The separated resin is directly collected in a storage tank while the separated water is forced through a circulating pump to a gas-liquid separator for separation into gas having radioactivity and water. The separated gas is led to a radioactive gas treatment station while the water deprived of the gas is recirculated by a drive water pump for repeated use. (Kamimura, M.)

  19. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  20. Mechanism for transporting used resin

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Y; Yusa, H; Kamiya, K

    1975-01-16

    In the operation of a light water reactor type atomic power plant the objectives is to permit transport and reuse of used ion exchange resin used for the filtering or cleaning of cooling water or the desalting of radioactive exhaust liquid through an ejector. Used ion exchange resin within a desalter having high radioactivity is withdrawn through the action of an ejector and led to a solid-liquid separator for separation into used resin and water. The separated resin is directly collected in a storage tank while the separated water is forced through a circulating pump to a gas-liquid separator for separation into gas having radioactivity and water. The separated gas is led to a radioactive gas treatment station while the water deprived of the gas is recirculated by a drive water pump for repeated use.

  1. [Titration comparative study of TOPINA Tablets in patients with localization related epilepsy: double-blind comparative study by rapid and slow titration methods].

    Science.gov (United States)

    Kaneko, Sunao; Inoue, Yushi; Sasagawa, Mutsuo; Kato, Masaaki

    2012-04-01

    To compare the tolerability and efficacy of two titration methods (rapid and slow titration) for TOPINA Tablets with different dosages and periods of escalation, a double-blind comparative study was conducted in patients with localization-related epilepsy. A total of 183 patients were randomized to either rapid titration (initial dosage 100 mg/day increased by 100-200 mg at weekly intervals) or to slow titration (initial dosage 50 mg/day increased in 50 mg/day increments at weekly intervals). TOPINA Tablets were administered for 12 weeks to the maximum dosage of 400 mg/day. The incident of adverse events leading to treatment interruptions or withdrawals was 18.9% in rapid titration and 14.8% in slow titration, with no statistical significance (p = 0.554). The incident of adverse events and adverse reactions of slow titration was slightly lower than that of rapid titration. The common adverse events and adverse reactions reported in the two titration methods were comparable and were well tolerated. On the other hand, the efficacy of slow titration, percent reduction in seizure rate and responder rate, was comparable with that of rapid titration. In conclusion, there were no significant differences of therapeutic response to TOPINA Tablets between the two titration methods.

  2. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  3. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  4. Determination of uranium by direct titration with dipicolinic acid

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1984-01-01

    Direct titration of uranium with dipicolinic acid, in the presence of Arsenazo I, is a simple, precise, and accurate method for uranium determination. The method is particularly attractive because it can be totally automated. Detecting the end point (color change from blue to pink) depends on the concentration range. For the Micro Method (1 to 20 ppM U in the solution titrated), the gradual color change is monitored spectrophotometrically. For the Macro Method (20 to 300 ppM), the end point is determined either visually or spectrophotometrically. The spectrophotometric end point is computed by fitting the titration curve. The relative standard deviation is +-1 to 3% for the Micro Method and +-0.3% for the Macro Method

  5. Two-phase titration of cerium(III) by permanganate

    International Nuclear Information System (INIS)

    Lazarev, A.I.; Lazareva, V.I.; Gerko, V.V.

    1987-01-01

    This paper presents a method for the two-phase titrimetric determination of cerium(III) with permanganate which does not require an expenditure of sugar and preliminary removal of chlorides and nitrates. The interaction of cerium(III) with permanganate at room temperature was studied as a function of the pH, the concentration of pyrophosphate, tetraphenylphosphonium (TPP), permanganate, and extraneous compounds, the rate of titration, and the time of stay of the solution in air before titration. The investigations were conducted according to the following methodology: water, solution of cerium(III) pyrophosphate, and TPP were introduced into an Erlenmeyer flask with a side branch near the bottom for clearer observation of the color of the chloroform phase. The authors established the given pH value, poured the water into a volume of 50 ml, and added chloroform. The result was titrated with permanganate solutions of various concentrations until a violet color appeared in the chloroform phase

  6. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    Energy Technology Data Exchange (ETDEWEB)

    Pesavento, Maria; Profumo, Antonella; Biesuz, Raffaela

    1987-09-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO/sub 3/-,I+,1/sub 2/ or I-) and a mixture, and is equal to 2 x 10/sup -7/ M. Chloride and bromide, even at very high concentrations, do not interfere.

  7. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    International Nuclear Information System (INIS)

    Pesavento, Maria; Profumo, Antonella

    1987-01-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO 3 -,I+,1 2 or I-) and a mixture, and is equal to 2 x 10 -7 M. Chloride and bromide, even at very high concentrations, do not interfere. (author)

  8. Error assessment in recombinant baculovirus titration: evaluation of different methods.

    Science.gov (United States)

    Roldão, António; Oliveira, Rui; Carrondo, Manuel J T; Alves, Paula M

    2009-07-01

    The success of baculovirus/insect cells system in heterologous protein expression depends on the robustness and efficiency of the production workflow. It is essential that process parameters are controlled and include as little variability as possible. The multiplicity of infection (MOI) is the most critical factor since irreproducible MOIs caused by inaccurate estimation of viral titers hinder batch consistency and process optimization. This lack of accuracy is related to intrinsic characteristics of the method such as the inability to distinguish between infectious and non-infectious baculovirus. In this study, several methods for baculovirus titration were compared. The most critical issues identified were the incubation time and cell concentration at the time of infection. These variables influence strongly the accuracy of titers and must be defined for optimal performance of the titration method. Although the standard errors of the methods varied significantly (7-36%), titers were within the same order of magnitude; thus, viral titers can be considered independent of the method of titration. A cost analysis of the baculovirus titration methods used in this study showed that the alamarblue, real time Q-PCR and plaque assays were the most expensive techniques. The remaining methods cost on average 75% less than the former methods. Based on the cost, time and error analysis undertaken in this study, the end-point dilution assay, microculture tetrazolium assay and flow cytometric assay were found to be the techniques that combine all these three main factors better. Nevertheless, it is always recommended to confirm the accuracy of the titration either by comparison with a well characterized baculovirus reference stock or by titration using two different methods and verification of the variability of results.

  9. Method of solidifying radioactive ion exchange resin

    International Nuclear Information System (INIS)

    Minami, Yuji; Tomita, Toshihide

    1989-01-01

    Spent anion exchange resin formed in nuclear power plants, etc. generally catch only a portion of anions in view of the ion exchange resins capacity and most of the anions are sent while possessing activities to radioactive waste processing systems. Then, the anion exchange resins increase the specific gravity by the capture of the anions. Accordingly, anions are caused to be captured on the anion exchange resin wastes such that the specific gravity of the anion exchange resin wastes is greater than that of the thermosetting resins to be mixed. This enables satisfactory mixing with the thermosetting resins and, in addition, enables to form integral solidification products in which anion exchange resins and cation exchange resins are not locallized separately and which are homogenous and free from cracks. (T.M.)

  10. Construction and use of an optical semi-automatic titrator employing the technique of reflectance photometry

    International Nuclear Information System (INIS)

    Hwang, Hoon

    2001-01-01

    An optical semi-automatic titrator was constructed employing the technique of the reflectance spectrometry and was tested for the determination of the end points of the acid-base, precipitation, and EDTA titrations. And since the current optical semi-automatic titrator built on the principle of the reflectance spectrometry could be successfully used even for the determination of the end of the end point in the precipitation titration where the solid particles are formed during the titration process, it was found to be feasible that a completely automated optical titrator would be designed and built based on the current findings

  11. Disposal of bead ion exchange resin wastes

    International Nuclear Information System (INIS)

    Gay, R.L.; Granthan, L.F.

    1985-01-01

    Bead ion exchange resin wastes are disposed of by a process which involves spray-drying a bead ion exchange resin waste in order to remove substantially all of the water present in such waste, including the water on the surface of the ion exchange resin beads and the water inside the ion exchange resin beads. The resulting dried ion exchange resin beads can then be solidified in a suitable solid matrix-forming material, such as a polymer, which solidifies to contain the dried ion exchange resin beads in a solid monolith suitable for disposal by burial or other conventional means

  12. Clinical Effectiveness and Dose Titration in Pediatric Practice

    Directory of Open Access Journals (Sweden)

    Yu.V. Marushko

    2016-02-01

    Full Text Available The paper is devoted to the questions of usage of one of the popular antipyretic and anesthetic drug in pediatric practice — ibuprofen. In the article there are generalized literature data and own experience in ibuprofen dose titration in single dose 5 and 10 mg/kg depending on clinical situation.

  13. Uranium coulometric titration. Application to the determination of traces

    International Nuclear Information System (INIS)

    Bergey, C.

    After a description of the device, the means developed to improve the titration method are presented. Coulometry enables to determine U with an accuracy of 0,1% in samples of only several tenths of a milligram. This method is rapid but not intended for routine analysis [fr

  14. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    Science.gov (United States)

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  15. Electroconvulsive therapy stimulus titration: Not all it seems.

    Science.gov (United States)

    Rosenman, Stephen J

    2018-05-01

    To examine the provenance and implications of seizure threshold titration in electroconvulsive therapy. Titration of seizure threshold has become a virtual standard for electroconvulsive therapy. It is justified as individualisation and optimisation of the balance between efficacy and unwanted effects. Present day threshold estimation is significantly different from the 1960 studies of Cronholm and Ottosson that are its usual justification. The present form of threshold estimation is unstable and too uncertain for valid optimisation or individualisation of dose. Threshold stimulation (lowest dose that produces a seizure) has proven therapeutically ineffective, and the multiples applied to threshold to attain efficacy have never been properly investigated or standardised. The therapeutic outcomes of threshold estimation (or its multiples) have not been separated from simple dose effects. Threshold estimation does not optimise dose due to its own uncertainties and the different short-term and long-term cognitive and memory effects. Potential harms of titration have not been examined. Seizure threshold titration in electroconvulsive therapy is not a proven technique of dose optimisation. It is widely held and practiced; its benefit and harmlessness assumed but unproven. It is a prematurely settled answer to an unsettled question that discourages further enquiry. It is an example of how practices, assumed scientific, enter medicine by obscure paths.

  16. Acid/base titrations of simulated PWR crevice environments

    International Nuclear Information System (INIS)

    Pang, J.; Macdonald, D.D.; Millett, P.J.

    1993-01-01

    The construction and operation of a titration system that is capable of exploring the acid/base properties of aqueous systems at temperatures solution is measured using YSZ sensors of the type Hg/HgO/ZrO 2 (Y 2 O 3 )/Solution in conjunction with a suitable reference electrode. The use of the system for measuring the pH of the titrated solutions (NaOH/H 2 SO 4 ) is discussed, and we show that the YSZ pH sensor is capable of consistent and precise pH measurements at elevated temperature (275-325 degrees C) and pressures (100-150 bars). However, the accuracy of the measured pH depends critically on the performance of the reference electrode. In the present work, we ensure the viability of the reference electrode. In the present work, we ensure the viability of the reference electrode by periodically calibrating it in situ using the pH sensor and a standard solution of known pH versus temperature characteristics. The titration data obtained in this study are compared with predictions from EPRI's MULTEQ code, and are found to be in satisfactory agreement in the alkaline pH region. Observed discrepancies in the acidic pH region between the two sets of data are attributed to corrosion of the alloys used to fabricate the titration system

  17. A dipstick sensor for coulometric acid-base titrations

    NARCIS (Netherlands)

    Olthuis, Wouter; van der Schoot, B.H.; Chavez, F.; Bergveld, Piet

    1989-01-01

    By performing an acid-base titration by coulometric generation of OH− or H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in

  18. Using Spreadsheets to Produce Acid-Base Titration Curves.

    Science.gov (United States)

    Cawley, Martin James; Parkinson, John

    1995-01-01

    Describes two spreadsheets for producing acid-base titration curves, one uses relatively simple cell formulae that can be written into the spreadsheet by inexperienced students and the second uses more complex formulae that are best written by the teacher. (JRH)

  19. Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool

    Science.gov (United States)

    Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah

    2018-01-01

    The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…

  20. Automation of potentiometric titration with a personal computer using ...

    African Journals Online (AJOL)

    sampling was designed and tested for automation of potentiometric titrations with personal ... automation permits us to carry out new types of experiments, such as those requiring ... have proved to be very useful in routine tasks but not in research, due to their ... This is done by a simple delay sub-routine in data acquisition.

  1. A General Simulator for Acid-Base Titrations

    Science.gov (United States)

    de Levie, Robert

    1999-07-01

    General formal expressions are provided to facilitate the automatic computer calculation of acid-base titration curves of arbitrary mixtures of acids, bases, and salts, without and with activity corrections based on the Davies equation. Explicit relations are also given for the buffer strength of mixtures of acids, bases, and salts.

  2. Evaluation of modified boehm titration methods for use with biochars.

    Science.gov (United States)

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  3. Action of ionizing radiation on epoxy resins

    Energy Technology Data Exchange (ETDEWEB)

    Van de Voorde, M. E.

    1970-12-01

    The resistance of classical and experimental epoxy resins to irradiation was studied. The resistance to irradiation of epoxy resins of diverse compositions as well as the development of resins having a radioresistance that approaches that of certain ceramics are discussed. Sources of irradiation and the techniques of dosimetry used are described. The structures of certain epoxy resins and of hardeners are given. The preparation of these resins and their physical properties is described. The effects of radiation on epoxy resins, as well as conditions of irradiation, and suggested mechanisms for degradation of the irradiated resins are discussed. The relationship between chemical structure of the resins and their physical properties is evaluated. (115 references) (JCB)

  4. Method for loading resin beds

    International Nuclear Information System (INIS)

    Notz, K.J.; Rainey, R.H.; Greene, C.W.; Shockley, W.E.

    1978-01-01

    An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145 to 200 0 C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145 0 C with a second aqueous component to provide a gaseous phase containing HNO 3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate

  5. When acid-base titrations are carried out in unusual conditions

    Directory of Open Access Journals (Sweden)

    Domenico De Marco

    2012-12-01

    Full Text Available Uncommon aspects in acid-base titrations are presented, which occur in titrations between both mono- and/or poly-functional acid and bases but are rarely introduced in ordinary analytical chemistry courses.

  6. Resin for processing radioactive waste water

    International Nuclear Information System (INIS)

    Onozuka, Teruo; Shindo, Manabu; Kiba, Hideaki; Kubota, Hirohisa; Sawada, Shintaro.

    1995-01-01

    The present invention concerns an anionic exchange resin having a long service life with less radiation degradation. The resin is an anionic exchange resin in which a trimethyl ammonium group is introduced to a copolymer of 4-bromo-butoxymethyl styrene and divinyl benzene. The resin is excellent in economic performance, and can reduce the frequency for the exchange of cross-linked anionic exchangers. (T.M.)

  7. Resin for processing radioactive waste water

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Teruo; Shindo, Manabu [Tohoku Electric Power Co., Inc., Sendai (Japan); Kiba, Hideaki; Kubota, Hirohisa; Sawada, Shintaro

    1995-11-07

    The present invention concerns an anionic exchange resin having a long service life with less radiation degradation. The resin is an anionic exchange resin in which a trimethyl ammonium group is introduced to a copolymer of 4-bromo-butoxymethyl styrene and divinyl benzene. The resin is excellent in economic performance, and can reduce the frequency for the exchange of cross-linked anionic exchangers. (T.M.).

  8. 21 CFR 177.1680 - Polyurethane resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyurethane resins. 177.1680 Section 177.1680 Food... of Single and Repeated Use Food Contact Surfaces § 177.1680 Polyurethane resins. The polyurethane...) For the purpose of this section, polyurethane resins are those produced when one or more of the...

  9. Method of removing contaminants from plastic resins

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-11-18

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  10. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-12-30

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  11. Power lies in interdisciplinary cooperation / Kärt Summatavet ; interv. Kärt Blumberg

    Index Scriptorium Estoniae

    Summatavet, Kärt, 1963-

    2008-01-01

    Ehtekunstnik Kärt Summatavet oma uudsest meetodist ehete valmistamisel - paberil oleva kujutise ülekandmisest arvuti abil metallile, mille ta töötas väljas oma doktoritöö raames Soomes Helsingi Kunsti- ja Disainiülikoolis ning mis pälvis Soulis toimunud ülemaailmsel naisleiutajate konkursil hõbemedali

  12. Acidity titration curves - a versatile tool for the characterisation of acidic mine waste water

    International Nuclear Information System (INIS)

    Fyson, A.

    2000-01-01

    Acidity titrations with NaOH are valuable tools for characterisation of acidic mine waters. - Titrations can be used to estimate metal concentrations. - Titrations can be carried out in the field, minimising changes in water chemistry due to sample handling time and procedure. (orig.)

  13. Colloid Titration--A Rapid Method for the Determination of Charged Colloid.

    Science.gov (United States)

    Ueno, Keihei; Kina, Ken'yu

    1985-01-01

    "Colloid titration" is a volumetric method for determining charged polyelectrolytes in aqueous solutions. The principle of colloid titration, reagents used in the procedure, methods of endpoint detection, preparation of reagent solutions, general procedure used, results obtained, and pH profile of colloid titration are considered. (JN)

  14. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    Science.gov (United States)

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  15. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    Science.gov (United States)

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  16. Resins production: batch plant automation

    International Nuclear Information System (INIS)

    Banti, M.; Mauri, G.

    1996-01-01

    Companies that look for automation in their plants without external resources, have at their disposal flexible, custom and easy to use DCS, open towards PLC. In this article it is explained why Hoechts has followed this way of new plants for resins production automation

  17. Occupational exposure to epoxy resins

    NARCIS (Netherlands)

    Terwoert, J.; Kersting, K.

    2014-01-01

    Products based on epoxy resins as a binder have become popular in various settings, among which the construction industry and in windmill blade production, as a result of their excellent technical properties. However, due to the same properties epoxy products are a notorious cause of allergic skin

  18. Synthesis and characterization of carboxylic cation exchange bio-resin for heavy metal remediation.

    Science.gov (United States)

    Kulkarni, Vihangraj V; Golder, Animes Kumar; Ghosh, Pranab Kumar

    2018-01-05

    A new carboxylic bio-resin was synthesized from raw arecanut husk through mercerization and ethylenediaminetetraacetic dianhydride (EDTAD) carboxylation. The synthesized bio-resin was characterized using thermogravimetric analysis, field emission scanning electron microscopy, proximate & ultimate analyses, mass percent gain/loss, potentiometric titrations, and Fourier transform infrared spectroscopy. Mercerization extracted lignin from the vesicles on the husk and EDTAD was ridged in to, through an acylation reaction in dimethylformamide media. The reaction induced carboxylic groups as high as 0.735mM/g and a cation exchange capacity of 2.01meq/g functionalized mercerized husk (FMH). Potentiometric titration data were fitted to a newly developed single-site proton adsorption model (PAM) that gave pKa of 3.29 and carboxylic groups concentration of 0.741mM/g. FMH showed 99% efficiency in Pb(II) removal from synthetic wastewater (initial concentration 0.157mM), for which the Pb(II) binding constant was 1.73×10 3 L/mol as estimated from modified PAM. The exhaustion capacity was estimated to be 18.7mg/g of FMH. Desorption efficiency of Pb(II) from exhausted FMH was found to be about 97% with 0.1N HCl. The FMH simultaneously removed lead and cadmium below detection limit from a real lead acid battery wastewater along with the removal of Fe, Mg, Ni, and Co. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Oxygen index tests of thermosetting resins

    Science.gov (United States)

    Gilwee, W. J., Jr.; Parker, J. A.; Kourtides, D. A.

    1980-01-01

    The flammability characteristics of nine thermosetting resins under evaluation for use in aircraft interiors are described. These resins were evaluated using the Oxygen Index (ASTM 2863) testing procedure. The test specimens consisted of both neat resin and glass reinforced resin. When testing glass-reinforced samples it was observed that Oxygen Index values varied inversely with resin content. Oxygen values were also obtained on specimens exposed to temperatures up to 300 C. All specimens experienced a decline in Oxygen Index when tested at an elevated temperature.

  20. Commercial Ion Exchange Resin Vitrification Studies

    International Nuclear Information System (INIS)

    Cicero-Herman, C.A

    2002-01-01

    In the nuclear industry, ion exchange resins are used for purification of aqueous streams. The major contaminants of the resins are usually the radioactive materials that are removed from the aqueous streams. The use of the ion exchange resins creates a waste stream that can be very high in both organic and radioactive constituents. Therefore, disposal of the spent resin often becomes an economic problem because of the large volumes of resin produced and the relatively few technologies that are capable of economically stabilizing this waste. Vitrification of this waste stream presents a reasonable disposal alternative because of its inherent destruction capabilities, the volume reductions obtainable, and the durable product that it produces

  1. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  2. Coulometric thermometric titration of halides in molten calcium nitrate tetrahydrate.

    Science.gov (United States)

    Zsigrai, I J; Bartusz, D B

    1983-01-01

    A method for coulometric thermometric precipitation titrations of chloride, bromide and iodide in molten calcium nitrate tetrahydrate at 55 degrees with coulometrically generated silver ions has been developed. The change in temperature during the titration is followed with the aid of a thermistor bridge coupled to a recorder. To minimize the temperature effect of the passage of current through the melt, two thermistors are connected in opposition in the bridge, with one in the anodic and the other in the cathodic cell compartment. Amounts of 62-80 mumole of halide have been determined with relative error below 0.4% and relative standard deviation less than 2.7%. The relative error in determination of 40 mumole of iodide was + 2%.

  3. Application of cause-and-effect analysis to potentiometric titration.

    Science.gov (United States)

    Kufelnicki, A; Lis, S; Meinrath, G

    2005-08-01

    A first attempt has been made to interpret physicochemical data from potentiometric titration analysis in accordance with the complete measurement-uncertainty budget approach (bottom-up) of ISO and Eurachem. A cause-and-effect diagram is established and discussed. Titration data for arsenazo III are used as a basis for this discussion. The commercial software Superquad is used and applied within a computer-intensive resampling framework. The cause-and-effect diagram is applied to evaluation of seven protonation constants of arsenazo III in the pH range 2-10.7. The data interpretation is based on empirical probability distributions and their analysis by second-order correct confidence estimates. The evaluated data are applied in the calculation of a speciation diagram including uncertainty estimates using the probabilistic speciation software Ljungskile.

  4. Spray drying of bead resins: feasibility tests

    International Nuclear Information System (INIS)

    Gay, R.L.; Grantham, L.F.; Jones, L.J.

    1984-01-01

    Rockwell International has developed a volume reduction system for low-level reactor wastes based on drying the wastes in a heated-air spray dryer. The drying of slurries of sodium sulfate, boric acid, and powdered ion exchange resins was demonstrated in previous tests. The drying of bead ion exchange resins can be especially difficult due to the relatively large size of bead resins (about 500 to 800 microns) and their natural affinity for water. This water becomes part of the pore structure of the resins and normally comprises 50 t 60 wt % of the resin weight. A 76-cm-diameter spray dryer was used for feasibility tests of spray drying of cation and anion bead resins. These resins were fed to the dryer in the as-received form (similar to dewatered resins) and as slurries. A dry, free-flowing product was produced in all the tests. The volume of the spray-dried product was one-half to one-third the volume of the as-received material. An economic analysis was made of the potential cost savings that can be achieved using the Rockwel spray dryer system. In-plant costs, transportation costs, and burial costs of spray-dried resins were compared to similar costs for disposal of dewatered resins. A typical utility producing 170 m 3 (6,000 ft 3 ) per year of dewatered resins can save $600,000 to $700,000 per year using this volume reduction system

  5. Two-phase titration of cerium(3) by permanganate

    International Nuclear Information System (INIS)

    Lazarev, A.I.; Lazareva, V.I.; Gerko, V.V.

    1986-01-01

    Reaction of cerium (3) and permanganate was investigated at a room temperature depending on PH, concentrations of pyrophosphate, cerium (3), tetraphenylphosphonium and foreign compounds. Selective method of two-phase titration determination of cerium (3) by permanganate without using silver compounds, preliminary separation of chlorides, nitrates, was developed. The method was tested using alloys based on iron, nickel, REE, copper, cobalt (S r ≤0.008). Correctness is proved with method of standard additives

  6. Characterization of Native and Modified Starches by Potentiometric Titration

    OpenAIRE

    Soto, Diana; Urdaneta, Jose; Pernia, Kelly

    2014-01-01

    The use of potentiometric titration for the analysis and characterization of native and modified starches is highlighted. The polyelectrolytic behavior of oxidized starches (thermal and thermal-chemical oxidation), a graft copolymer of itaconic acid (IA) onto starch, and starch esters (mono- and diester itaconate) was compared with the behavior of native starch, the homopolymer, and the acid employed as a graft monomer and substituent. Starch esters showed higher percentages of acidity, follo...

  7. Determination of uranium and plutonium by sequential potentiometric titration

    International Nuclear Information System (INIS)

    Kato, Yoshiharu; Takahashi, Masao

    1976-01-01

    The determination of uranium and plutonium in mixed oxide fuels has been developed by sequential potentiometric titration. A weighed sample of uranium and plutonium oxides is dissolved in a mixture of nitric and hydrofluoric acids and the solution is fumed with sulfuric acid. After the reduction of uranium and plutonium to uranium(IV) and plutonium(III) by chromium(II) sulfate, 5 ml of buffer solution (KCl-HCl, pH 1.0) is added to the solution. Then the solution is diluted to 30 ml with water and the pH of the solution is adjusted to 1.0 -- 1.5 with 1 M sodium hydroxide. The solution is stirred until the oxidation of the excess of chromium(II) by air is completed. After the removal of dissolved oxygen by bubbling nitrogen through the solution for 10 minutes, uranium (IV) is titrated with 0.1 N cerium(IV) sulfate. Then, plutonium is titrated by 0.02 N cerium(IV) sulfate. When a mixture of uranium and plutonium is titrated with 0.1 N potassium dichromate potentiometrically, the potential change at the end point of plutonium is very small and the end point of uranium is also unclear when 0.1 N potassium permanganate is used as a titrant. In the present method, nitrate, fluoride and copper(II) interfere with the determination of plutonium and uranium. Iron interferes quantitatively with the determination of plutonium but not of uranium. Results obtained in applying the proposed method to 50 mg of mixtures of plutonium and uranium ((7.5 -- 50))% Pu were accurate to within 0.15 mg of each element. (auth.)

  8. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    Science.gov (United States)

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  9. A rapid method for titration of ascovirus infectivity.

    Science.gov (United States)

    Han, Ningning; Chen, Zishu; Wan, Hu; Huang, Guohua; Li, Jianhong; Jin, Byung Rae

    2018-05-01

    Ascoviruses are a recently described family and the traditional plaque assay and end-point PCR assay have been used for their titration. However, these two methods are time-consuming and inaccurate to titrate ascoviruses. In the present study, a quick method for the determination of the titer of ascovirus stocks was developed based on ascovirus-induced apoptosis in infected insect cells. Briefly, cells infected with serial dilutions of virus (10 -2 -10 -10 ) for 24 h were stained with trypan blue. The stained cells were counted, and the percentage of nonviable cells was calculated. The stained cell rate was compared between virus-infected and control cells. The minimum-dilution group that had a significant difference compared with control and the maximum-dilution group that had no significant difference were selected and then compared each well of the two groups with the average stained cell rate of control. The well was marked as positive well if the stained cell rate was higher than the average stained cell rate of control wells; otherwise, the well was marked as negative wells. The percentage of positive wells were calculated according to the number of positive. Subsequently, the virus titer was calculated through the method of Reed and Muench. This novel method is rapid, simple, reproducible, accurate, and less material-consuming and eliminates the subjectivity of the other procedures for titrating ascoviruses. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Interaction of molybdenum (6) with potassium benzyldithiocarbaminate during amperometric titration

    International Nuclear Information System (INIS)

    Galushko, S.V.; Usatenko, Yu.I.

    1975-01-01

    The paper is an amperometric study of the mechanism of interaction between molybdenum (VI) and potassium benzyl dithiocarbamate [BDTC] which was based on the use of voltamperometry, electron paramagnetic resonance, infrared spectroscopy, potentiometry and elemental analysis. In amperometric titration Mo(VI) with BDTC (pH 4-2) forms a red compound of low solubility. In more acidic media the intensity of coloration is increased and a violet hue develops. On the basis of the data obtained it is concluded that in the amperometric titration of Mo(VI) with potassium BDTC there is first formation of a Mo(VI) compound, which subsequently acquires a red colour as a result of the reduction of Mo(VI) to Mo(V). It was also established that the degree of reduction is small where titration is carried out in the range pH 4.8-0.1. Quantitative determination of Mo is performed most effectively in slightly acidic media. Mo reacts with potassium BDTC in a ratio of 1:2. (E.P.)

  11. EDF specifications on nuclear grade resins

    International Nuclear Information System (INIS)

    Mascarenhas, Darren; Gressier, Frederic; Taunier, Stephane; Le-Calvar, Marc; Ranchoux, Gilles; Marteau, Herve; Labed, Veronique

    2012-09-01

    Ion exchange resins are widely used across EDF, especially within the nuclear division for the purification of water. Important applications include primary circuit, secondary circuit and effluent treatment, which require high quality nuclear grade resins to retain the dissolved species, some of which may be radioactive. There is a need for more and more efficient purification in order to decrease worker dose during maintenance but also to decrease volumes of radioactive resin waste. Resin performance is subject to several forms of degradation, including physical, chemical, thermal and radioactive, therefore appropriate resin properties have to be selected to reduce such effects. Work has been done with research institutes, manufacturers and on EDF sites to select these properties, create specifications and to continuously improve on these specifications. An interesting example of research regarding resin performance is the resin degradation under irradiation. Resins used in the CVCS circuit of EDF nuclear power plants are subject to irradiation over their lifetime. A study was carried out on the effects of total integrated doses of 0.1, 1 and 10 MGy on typically used EDF mixed bed resins in a 'mini-CVCS' apparatus to simultaneously test actual primary circuit fluid. The tests confirmed that the resins still perform efficiently after a typical CVCS radiation dose. Certain resins also need additional specifications in order to maintain the integrity of the particular circuits they are used in. Recently, EDF has updated its requirements on these high purity nuclear grade resins, produced generic doctrines for all products and materials used on site which include resins of all grades, and as a result have also updated a guide on recommended resin usage for the French fleet of reactors. An overview of the evolutions will be presented. (authors)

  12. Foam, Foam-resin composite and method of making a foam-resin composite

    Science.gov (United States)

    Cranston, John A. (Inventor); MacArthur, Doug E. (Inventor)

    1995-01-01

    This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.

  13. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  14. Experiment vs simulation RT WFNDEC 2014 benchmark: CIVA results

    International Nuclear Information System (INIS)

    Tisseur, D.; Costin, M.; Rattoni, B.; Vienne, C.; Vabre, A.; Cattiaux, G.; Sollier, T.

    2015-01-01

    The French Atomic Energy Commission and Alternative Energies (CEA) has developed for years the CIVA software dedicated to simulation of NDE techniques such as Radiographic Testing (RT). RT modelling is achieved in CIVA using combination of a determinist approach based on ray tracing for transmission beam simulation and a Monte Carlo model for the scattered beam computation. Furthermore, CIVA includes various detectors models, in particular common x-ray films and a photostimulable phosphor plates. This communication presents the results obtained with the configurations proposed in the World Federation of NDEC 2014 RT modelling benchmark with the RT models implemented in the CIVA software

  15. Experiment vs simulation RT WFNDEC 2014 benchmark: CIVA results

    Energy Technology Data Exchange (ETDEWEB)

    Tisseur, D., E-mail: david.tisseur@cea.fr; Costin, M., E-mail: david.tisseur@cea.fr; Rattoni, B., E-mail: david.tisseur@cea.fr; Vienne, C., E-mail: david.tisseur@cea.fr; Vabre, A., E-mail: david.tisseur@cea.fr; Cattiaux, G., E-mail: david.tisseur@cea.fr [CEA LIST, CEA Saclay 91191 Gif sur Yvette Cedex (France); Sollier, T. [Institut de Radioprotection et de Sûreté Nucléaire, B.P.17 92262 Fontenay-Aux-Roses (France)

    2015-03-31

    The French Atomic Energy Commission and Alternative Energies (CEA) has developed for years the CIVA software dedicated to simulation of NDE techniques such as Radiographic Testing (RT). RT modelling is achieved in CIVA using combination of a determinist approach based on ray tracing for transmission beam simulation and a Monte Carlo model for the scattered beam computation. Furthermore, CIVA includes various detectors models, in particular common x-ray films and a photostimulable phosphor plates. This communication presents the results obtained with the configurations proposed in the World Federation of NDEC 2014 RT modelling benchmark with the RT models implemented in the CIVA software.

  16. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    Science.gov (United States)

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  17. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    Science.gov (United States)

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  18. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    Science.gov (United States)

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  19. Mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists); Mammadiagnostik fuer MTRA/RT

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann

    2014-07-01

    The text book on mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists) covers the following issues: Anatomy, development and physiology of mammary glands; tumor development an breast cancer risk; pathology, non-imaging diagnostics; mammography: physical-technical fundamentals; mammography: analogue technique; mammography: digital technique; mammography: quality assurance; mammography: legal questions and radiation protection; mammography: new developments; mammography: setting technique; mammography: use and appraisal; mamma-sonography: technique and methodology; mamma-sonography: assignment and appraisal, mamma-NMR: technique and methodology; mamma-NMR: assignment and appraisal lymph node diagnostics; mamma interventions; biopsy; mamma interventions: marking examination concepts; therapeutic concepts; hygienic concepts; communication and interaction.

  20. Solidifying power station resins and sludges

    International Nuclear Information System (INIS)

    Willis, A.S.D.; Haigh, C.P.

    1984-01-01

    Radioactive ion exchange resins and sludges arise at nuclear power stations from various operations associated with effluent treatment and liquid waste management. As the result of an intensive development programme, the Central Electricity Generating Board (CEGB) has designed a process to convert power station resins and sludges into a shielded, packaged solid monolithic form suitable for final disposal. Research and development, the generic CEGB sludge/resin conditioning plant and the CEGB Active Waste Project are described. (U.K.)

  1. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  2. Titratable acidity of beverages influences salivary pH recovery

    Directory of Open Access Journals (Sweden)

    Livia Maria Andaló TENUTA

    2015-01-01

    Full Text Available A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively. Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  3. Titratable acidity of beverages influences salivary pH recovery.

    Science.gov (United States)

    Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido

    2015-01-01

    A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and pH 5.5, respectively). Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.

  4. Modelling of acid-base titration curves of mineral assemblages

    Directory of Open Access Journals (Sweden)

    Stamberg Karel

    2016-01-01

    Full Text Available The modelling of acid-base titration curves of mineral assemblages was studied with respect to basic parameters of their surface sites to be obtained. The known modelling approaches, component additivity (CA and generalized composite (GC, and three types of different assemblages (fucoidic sandstones, sedimentary rock-clay and bentonite-magnetite samples were used. In contrary to GC-approach, application of which was without difficulties, the problem of CA-one consisted in the credibility and accessibility of the parameters characterizing the individual mineralogical components.

  5. Semi-automated potentiometric titration method for uranium characterization.

    Science.gov (United States)

    Cristiano, B F G; Delgado, J U; da Silva, J W S; de Barros, P D; de Araújo, R M S; Lopes, R T

    2012-07-01

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Removal of radiocesium using cation exchange resin

    International Nuclear Information System (INIS)

    Morita-Murase, Yuko; Mizumura, Ryosuke; Tachibana, Yoshitaka; Kanazawa, Hideko

    2013-01-01

    Cation exchange resins (calcium polystyrene sulfonate, Ca-resin and sodium polystyrene sulfonate, Na-resin) have been used as agents to improve hyperkerlemia. For removing 137 Cs from the human body, the adsorption ability of the resin for 137 Cs was examined and evaluated. Resin (0.03 g) and 137 Cs (ca.1 kBq) were introduced into 3 mL of water, the Japanese Pharmacopoeia 1st fluid for a dissolution test (pH 1.2) and 2nd fluid (pH 6.8), respectively, and shaken. After 1-3 hours, the 137 Cs adsorption (%) of Na-resin was 99% in water, 60% in a pH 1.2 fluid and, 66% in a pH 6.8 fluid. By adding potassium, the 137 Cs adsorption (%) of Ca-resin was reduced. However, the 137 Cs adsorption (%) of Na-resin was almost unchanged. These results show that both resins have adsorption ability for 137 Cs in the stomach and the intestines. Therefore, the proposed method will be an effective means in the case of a radiological emergency due to 137 Cs. (author)

  7. The absorption of plutonium by anion resins

    Energy Technology Data Exchange (ETDEWEB)

    Durham, R. W.; Mills, R.

    1961-10-15

    Equilibrium experiments have shown Pu{sup +4} to be absorbed from nitric acid onto an anion resin as a complex anion Pu(NO{sub 3}){sub 6}{sup -2}. The amount of absorption is dependent on the plutonium and nitric acid concentrations in the equilibrium solution with a maximum at 7N to 8N HNO{sub 3}. A low cross-linked resin has a higher capacity and reaches equilibrium more rapidly than the normally supplied resin. Saturation capacity of one per cent cross-linked Nalcite SBR (Dowex 1), 50 -- 100 mesh, is 385 mg Pu/gram dry resin. (author)

  8. Novel silica-based ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    Eichrom`s highly successful Diphonixo resin resembles a conventional ion exchange resin in its use of sulfonic acid ligands on a styrene- divinylbenzene matrix. Diphonix resin exhibits rapid exchange kinetics that allow economical operation of ion exchange systems. Unlike conventional resins, Diphonix resin contains chelating ligands that are diphosphonic acid groups that recognize and remove the targeted metals and reject the more common elements such as sodium, calcium and magnesium. This latter property makes Diphonix ideal for many industrial scale applications, including those involving waste treatment. For treatment of low-level, transuranic (TRU) and high- level radioactive wastes, Diphonix`s polystyrene backbone hinders its application due to radiolytic stability of the carbon-hydrogen bonds and lack of compatibility with expected vitrification schemes. Polystyrene-based Diphonix is approximately 60% carbon- hydrogen. In response to an identified need within the Department of Energy for a resin with the positive attributes of Diphonix that also exhibits greater radiolytic stability and final waste form compatibility, Eichrom has successfully developed a new, silica-based resin version of Diphonix. Target application for this new resin is for use in environmental restoration and waste management situations involving the processing of low-level, transuranic and high-level radioactive wastes. The resin can also be used for processing liquid mixed waste (waste that contains low level radioactivity and hazardous constituents) including mixed wastes contaminated with organic compounds. Silica-based Diphonix is only 10% carbon-hydrogen, with the bulk of the matrix silica.

  9. Reverse transcriptase-quantitative polymerase chain reaction (RT ...

    African Journals Online (AJOL)

    The reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is a highly specific polymerase chain reaction (PCR) method that allows one to detect very low transcription levels of functional gene(s) in soil. RT-qPCR helps us to know the active members of the microbial community, and their activities can be ...

  10. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    Directory of Open Access Journals (Sweden)

    Lorentz JÄNTSCHI

    2002-12-01

    Full Text Available The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titrations/v1.1/ The method allows expressing the value of pH in any point of titration process and permits to observe the equivalence point of titration.

  11. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.

  12. Computer controlled titration with piston burette or peristaltic pump - a comparison.

    Science.gov (United States)

    Hoffmann, W

    1996-09-01

    The advantages and problems of the use of piston burettes and peristaltic pumps for dosage of titrant solutions in automatic titrations are shown. For comparison, only the dosing devices were exchanged and all other components and conditions remained unchanged. The results of continuous acid base titration show good agreement and comparable reproducibility. Potentiometric sensors (glass electrodes) with different equilibration behaviour influence the results. The capability of such electrodes was tested. Conductometric measurements allow a much faster detection because there is no equilibration of electrodes. Piston burettes should be used for titration with very high precision, titration with organic solvents and slow titrations. Peristaltic pumps seem to be more suitable for continuous titrations and long time operation without service.

  13. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    OpenAIRE

    E. L. Artanova; E. V. Saleeva; I. M. Sokolov; Y. G. Shvarts

    2011-01-01

    Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR) were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, a...

  14. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    OpenAIRE

    Eva Tavčar; Erika Turk; Samo Kreft

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes p...

  15. The determination of titratable acidity and total tannins in red wine

    OpenAIRE

    Rajković Miloš B.; Sredović Ivana D.

    2009-01-01

    Titration acidity and content of total tannins in mass-market red wines are analyzed in this paper. The content of total acids in wine, expressed through wine acid, was analyzed by potentiometric titration on 7.00 pH value. According to titratable acidity in analyzed wines, all wines (only) with analyzed parameters according to Regulations about wine quality. The analysis of differential potentiometric curves shows that these curves can give the answer to the question if non organic substance...

  16. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    OpenAIRE

    Hu, Jian-Qiang; Zhang, Jian-Jian; Yang, Shi-Zhao; Xin, Yong-Liang; Guo, Li; Yao, Ting

    2017-01-01

    Water content in jet fuels is detected by thermometric titration (TMT), and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicate...

  17. Potentiometric titration of molybdenum (6) with a cathode-polarized solid electrode

    International Nuclear Information System (INIS)

    Boeva, L.V.; Kimstach, V.A.; Bagdasarov, K.N.

    1980-01-01

    The possibility has been studied of using solid electrodes for potentiometric precipitation titration of molybdenum (6). A cathode-polarized electrode, electrochemically covered with a molybdenum blue layer, can be used as indicator electrode. The best results were obtained during deposition of molybdenum blue on a tungsten electrode. The mechanism of electrode work during titration has been investigated. A procedure has been developed of titration of molybdenum (6) in acid solutions using hydroxylamine N-aryl derivatives as titrants

  18. Further investigation on the degree of deacetylation of chitosan determined by potentiometric titration

    OpenAIRE

    Kamal Sweidan; Abdel-Motalleb Jaber; Nawzat Al-jbour; Rana Obaidat; Mayyas Al- Remawi; Adnan Badwan

    2011-01-01

    The degree of deacetylation (DDA) of various low molecular weight chitosan (LMWC) species as the hydrochloride and free base (amine form) was determined by direct and back potentiometric titration, respectively. The DDA values obtained for the chitosan hydrochloride by direct titration were greater than 93% for all oligomers tested (Molecular weight (Mwt) between about 1.3 to 30.0 kDa). However, the DDA values obtained for chitosan amine oligomers using back titration were significantly lower...

  19. Constant-pH molecular dynamics using stochastic titration

    Science.gov (United States)

    Baptista, António M.; Teixeira, Vitor H.; Soares, Cláudio M.

    2002-09-01

    A new method is proposed for performing constant-pH molecular dynamics (MD) simulations, that is, MD simulations where pH is one of the external thermodynamic parameters, like the temperature or the pressure. The protonation state of each titrable site in the solute is allowed to change during a molecular mechanics (MM) MD simulation, the new states being obtained from a combination of continuum electrostatics (CE) calculations and Monte Carlo (MC) simulation of protonation equilibrium. The coupling between the MM/MD and CE/MC algorithms is done in a way that ensures a proper Markov chain, sampling from the intended semigrand canonical distribution. This stochastic titration method is applied to succinic acid, aimed at illustrating the method and examining the choice of its adjustable parameters. The complete titration of succinic acid, using constant-pH MD simulations at different pH values, gives a clear picture of the coupling between the trans/gauche isomerization and the protonation process, making it possible to reconcile some apparently contradictory results of previous studies. The present constant-pH MD method is shown to require a moderate increase of computational cost when compared to the usual MD method.

  20. Common Standards of Basal Insulin Titration in T2DM

    Science.gov (United States)

    Arnolds, Sabine; Heise, Tim; Flacke, Frank; Sieber, Jochen

    2013-01-01

    Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter, however, might have time constraints and have to deal with many kinds of diseases or with multimorbid patients, so their focus is not so much on lowering high blood glucose values. Thus, the physicians, as well as the patients themselves, are often reluctant to initiate and adjust insulin therapy, although basal insulin therapy is considered the appropriate strategy after oral antidiabetic drug failure, according to the latest international guidelines. A substantial number of clinical studies have shown that insulin initiation and optimization can be managed successfully by using titration algorithms—even in cases where patients themselves are the drivers of insulin titration. Nevertheless, tools and strategies are needed to facilitate this process in the daily life of both primary health care professionals and patients with diabetes. PMID:23759411

  1. Fast Proton Titration Scheme for Multiscale Modeling of Protein Solutions.

    Science.gov (United States)

    Teixeira, Andre Azevedo Reis; Lund, Mikael; da Silva, Fernando Luís Barroso

    2010-10-12

    Proton exchange between titratable amino acid residues and the surrounding solution gives rise to exciting electric processes in proteins. We present a proton titration scheme for studying acid-base equilibria in Metropolis Monte Carlo simulations where salt is treated at the Debye-Hückel level. The method, rooted in the Kirkwood model of impenetrable spheres, is applied on the three milk proteins α-lactalbumin, β-lactoglobulin, and lactoferrin, for which we investigate the net-charge, molecular dipole moment, and charge capacitance. Over a wide range of pH and salt conditions, excellent agreement is found with more elaborate simulations where salt is explicitly included. The implicit salt scheme is orders of magnitude faster than the explicit analog and allows for transparent interpretation of physical mechanisms. It is shown how the method can be expanded to multiscale modeling of aqueous salt solutions of many biomolecules with nonstatic charge distributions. Important examples are protein-protein aggregation, protein-polyelectrolyte complexation, and protein-membrane association.

  2. Titration of uranium trace amounts in waters environment

    International Nuclear Information System (INIS)

    Larabi-Gruet, N.; Ithurbide, A.; Poulesquen, A.; Beaucaire, C.; Peulon, S.; Chausse, A.

    2007-01-01

    In the framework of studies concerning the uranium migration in soils and rocks, it seems necessary to quantify the uranium(VI) dissolved in solution. In the environmental conditions, the uranium(VI) is present at trace amounts. The most adapted method to this study and easy to carry out is the Adsorptive Stripping Voltammetry. By addition of a compound (ligand) with a reducing and strong complexing power, the uranium(VI) present in solution is reduced into a U(VI)-ligand complex. This specie is then oxidized and adsorbed on the mercury droplet where an electrolytic pre-concentration of the element to determine the quantity of is carried out. At last, a cathodic re-dissolution of the specie adsorbed in the U(IV)-ligand complex is carried out. The chosen analytical method is the differential impulsional voltammetry. With this method, it is possible to quantify low electro-active species quantities (sensitivity ∼25 ppt (10 -10 mol.L -1 ) for the uranium). This titration method in solution has been optimized, at first, in a non complexing medium. Then, the uranium in solution has been titrated in media whose composition has been progressively complexed (additions of CO 3 2- , SO 4 2- , Cl - ..) for being at last representative of the environmental interstitial waters. At last, this study has been carried out too by ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) in order to compare the analysis sensitivity of these two detection methods. (O.M.)

  3. Radiometric titration of thallium(III) with EDTA

    International Nuclear Information System (INIS)

    Rao, V.R.S.; Pulla Rao, Ch.; Tataiah, G.

    1978-01-01

    Radioactive solutions containing very small amounts of thallium(III) can be determined by radiometric titration using ammonia as hydrolysing agent. Aqueous solution of thallium(I) (both inactive and radioactive) is treated with bromine water till the appearance of the brown colour of bromine, and the solution is warmed to 80 deg C to expel the excess bromine. By this procedure all thallium(I) is quantitatively oxidised to thallium(III). An aqueous solution of ammonia is added to precipitate thallium(III) as thallic oxide. It is then filtered, washed with water to free it from bromide and then dissolved in 2N HCl and the solution is then standardised. 2 ml of this solution is transferred to a 20 ml volumetric flask, 1 ml of radioactive thallium(III) solution to be standardised is added as well as incremental amounts of EDTA solution and mixed thoroughly. Uncomplexed thallium(III) is then precipitated by the addition of an ammonia solution and diluted to 20 ml. Required amount of this mixture is centrifuged. The beta activity of the supernatant aliquot is measured using a GM counter. Quantitative determination of Tl(III) in the range of 1-10 μM can be carried out. The interference of cations such as Au(III), iron(III), Ga(III) can be eliminated by pretreatment of the Tl(III) solution before carrying out radiometric titration. The results obtained are reproducible and accurate to +-3%. (T.I.)

  4. Semi-automated potentiometric titration method for uranium characterization

    Energy Technology Data Exchange (ETDEWEB)

    Cristiano, B.F.G., E-mail: barbara@ird.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Delgado, J.U.; Silva, J.W.S. da; Barros, P.D. de; Araujo, R.M.S. de [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear (PEN/COPPE), Universidade Federal do Rio de Janeiro (UFRJ), Ilha do Fundao, PO Box 68509, Rio de Janeiro, 21945-970 RJ (Brazil)

    2012-07-15

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. - Highlights: Black-Right-Pointing-Pointer We developed a semi-automatic version of potentiometric titration method. Black-Right-Pointing-Pointer The method is used for certification and characterization of uranium compounds. Black-Right-Pointing-Pointer The traceability of the method was assured by a K{sub 2}Cr{sub 2}O{sub 7} primary standard. Black-Right-Pointing-Pointer The results of U{sub 3}O{sub 8} reference material analyzed was consistent with certified value. Black-Right-Pointing-Pointer The uncertainty obtained, near 0.01%, is useful for characterization purposes.

  5. The role of titration schedule of topiramate for the development of depression in patients with epilepsy.

    Science.gov (United States)

    Mula, Marco; Hesdorffer, Dale C; Trimble, Michael; Sander, Josemir W

    2009-05-01

    To determine whether a fast titration schedule of topiramate (TPM) has different effects on the occurrence of depression, in relation to other risk factors for TPM-induced depression, including history of depression (HxDEP), febrile seizures (FS), and hippocampal sclerosis (HS). Using data from a large case registry of patients prescribed TPM, two models were constructed: Model 1 examined the independent effect of rapid TPM titration after separate adjustment for FS, HxDEP, and HS. Model 2 examined effect of the cooccurrence of rapid titration on the development of depression with each of these risk factors. A total of 423 patients were included (51.8% females), mean age (SD) 35.5 (11.8) years, mean duration of epilepsy of 22.2 (11.5) years. Forty-four patients (10.4%) developed depression during TPM therapy. A rapid TPM titration was associated with 5-fold increased risk of depression that increased to 12.7-fold in the presence of both FS and rapid TPM titration, 23.3-fold in the presence of both HxDEP and rapid TPM titration, and 7.6-fold in the presence of both HS and rapid TPM titration schedule. Our study suggests that a rapid titration schedule is associated with an increased risk of developing depression during TPM therapy. HxDEP and FS are major contraindications to the use of a rapid titration, with a 23.3-fold and 12.7 fold increased risk, respectively.

  6. Application of »Mass Titration« to Determination of Surface Charge of Metal Oxides

    OpenAIRE

    1998-01-01

    The mass titration method, used for the point of zero charge determination, was extended to the measurement of the surface charge density. The results agree with the common method, which is the acid-base titration of the colloidal suspension. The advantage of mass titration is that one does not need to perform blank titration, instead one simply adds metal oxide powder to the electrolyte aqueous solution of known pH. To cover the pH range above and below the point of zero charge, two experime...

  7. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  8. Ruthenium determination in new composite materials by coulometric titration with generated iron(2)

    International Nuclear Information System (INIS)

    Butakova, N.A.; Oganesyan, L.B.

    1983-01-01

    A coulometric technique is developed for ruthenium (4) titration with generated iron (2) in a mixture of hydrochloric-, sulfuric- and phosphoric acids with potentiometric and biammetric indication of the final titration point. Bi (3), Pd (2), Nb (5), Pt (4) Pb (2), Rh (3) do not interfere with the titration. Together with Ru (4) titrated are Ir (4), V (5), Au (3). The method is applied to analyze commercial samples of ruthenium dioxides, lead- and bismuth ruthenites, ruthenium pentafluorides containing 30-80% of ruthenium. The Ssub(r) values do not exceed 0.002

  9. Data processing for potentiometric precipitation titration of mixtures of isovalent ions by linear regression analysis

    International Nuclear Information System (INIS)

    Mar'yanov, B.M.; Shumar, S.V.; Gavrilenko, M.A.

    1994-01-01

    A method for the computer processing of the curves of potentiometric differential titration using the precipitation reactions is developed. This method is based on transformation of the titration curve into a line of multiphase regression, whose parameters determine the equivalence points and the solubility products of the formed precipitates. The computational algorithm is tested using experimental curves for the titration of solutions containing Hg(2) and Cd(2) by the solution of sodium diethyldithiocarbamate. The random errors (RSD) for the titration of 1x10 -4 M solutions are in the range of 3-6%. 7 refs.; 2 figs.; 1 tab

  10. Method for linearizing the potentiometric curves of precipitation titration in nonaqueous and aqueous-organic solutions

    International Nuclear Information System (INIS)

    Bykova, L.N.; Chesnokova, O.Ya.; Orlova, M.V.

    1995-01-01

    The method for linearizing the potentiometric curves of precipitation titration is studied for its application in the determination of halide ions (Cl - , Br - , I - ) in dimethylacetamide, dimethylformamide, in which titration is complicated by additional equilibrium processes. It is found that the method of linearization permits the determination of the titrant volume at the end point of titration to high accuracy in the case of titration curves without a potential jump in the proximity of the equivalent point (5 x 10 -5 M). 3 refs., 2 figs., 3 tabs

  11. Input to Resin Column Structural Analysis if Autocatalytic Resin Reaction Occurs in HB-Line Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Hallman, D.F.

    2001-07-10

    Solutions of plutonium in nitric acid are purified and concentrated using anion resin prior to precipitation. There have been instances of resin column explosions caused by autocatalytic reactions of anion resins in nitric acid within the DOE complex

  12. Properties of the Carboxylate ion exchange resins; Karboxylatjonbytarmassans egenskaper

    Energy Technology Data Exchange (ETDEWEB)

    Allard, Bert; Dario, Maarten [Oerebro Univ. (Sweden); Boren, Hans [Linkoepings Univ. (Sweden); Torstenfelt, Boerje [Swedpower, Stockholm (Sweden); Puigdomenech, Ignasi; Johansson, Claes [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    2002-09-01

    Weakly acidic, carboxylic resin has been selected, together with strong base anion resins, for water purification at the Forsmark 1 and 2 reactors. For the strong (but not the weak) ion exchange resin the Nuclear Power Inspectorate has given permission to dispose the spent resins in the SFR 1 (the Final Repository for Radioactive Operational Waste). This report gives a review of the carboxylic resins and comes to the conclusion that the resins are very stable and that there should not exist any risks for increased leaching of radionuclides from SFR 1 if these resins are disposed (compared to the strong resins)

  13. Resin Viscosity Influence on Fiber Compaction in Tapered Resin Injection Pultrusion Manufacturing

    Science.gov (United States)

    Masuram, N. B.; Roux, J. A.; Jeswani, A. L.

    2018-06-01

    Viscosity of the liquid resin effects the chemical and mechanical properties of the pultruded composite. In resin injection pultrusion manufacturing the liquid resin is injected into a specially designed tapered injection chamber through the injection slots present on top and bottom of the chamber. The resin is injected at a pressure so as to completely wetout the fiber reinforcements inside the tapered injection chamber. As the resin penetrates through the fibers, the resin also pushes the fibers away from the wall towards the center of chamber causing compaction of the fiber reinforcements. The fibers are squeezed together due to compaction, making resin penetration more difficult; thus higher resin injection pressures are required to efficaciously penetrate through the compacted fibers and achieve complete wetout. The impact of resin viscosity on resin flow, fiber compaction, wetout and on the final product is further discussed. Injection chamber design predominantly effects the resin flow inside the chamber and the minimum injection pressure required to completely wet the fibers. Therefore, a desirable injection chamber design is such that wetout occurs at lower injection pressures and at low internal pressures inside the injection chamber.

  14. Overview on resins available in microlithography

    International Nuclear Information System (INIS)

    Serre, B.; Schue, F.; Montginoul, C.; Giral, L.

    1985-01-01

    Lithographic equipments using electrons and X radiation are developed. Velocity and resolution requirements fix the nature of the material to irradiate. Circuit making principles are recalled here; resists (organic polymers) are employed for it. The different types of resins and then needed characteristics are reviewed here. In the scope of electron sensitive resins methyl polymethacrylate and derivative and its copolymers (and copolymers of methacrylonitrile) and reticulated copolymers are studied. Polysulfones are also presented (poly(buten-1 sulfone), poly(styrene sulfone), poly(methyl-1 cyclopentene-1 sulfone). The interest in photosensitive resins (such as AZ) as electron sensitive resins is recalled. In the field of negative resins, the polyepoxyds, polystyrene and halogenated derivates from polystyrene (CMS and PCMS), the poly(vinyl-2 naphtalene) and its derivatives (PSTTF) are presented. The X radiation sensitive resins are also reviewed: the methyl polymethacrylate and its halogenated derivates, the acrylic homopolymers and copolymers (example of poly(acrylate of chlorinated alcoyls). The resins developable by plasma are mentioned. At last, for photosensitive resins, the diazide polydiene systems are presented together with systems diazo-2 2H-naphtalenone-1. The systems with salt photolysis are just recalled [fr

  15. Epoxidation of linseed oil-Alkyd resins

    International Nuclear Information System (INIS)

    Motawie, A.M.; Ismail, E.A.; Mazroua, A.M.; Abd EI Aziem, M.S.; Ramadan, A.M.

    2004-01-01

    Three types of different linseed oil-alkyd resin ( Alk (I), Alk (II), and Alk (III) ) were prepared with the calculated amounts of mono glycerides and adipic acid (1:1, 1:2, and 2:1 Eq.Wt) respectively via monoglyceride method. The obtained alkyd resins were epoxidized via reaction with the calculated quantities of peracetic acid, which was prepared by the reaction of acetic anhydride with H 2 O 2 . Epoxidation occurred with the ratio (1: 1, 1 :3, and 1:6 Eq. Wt) of alkyd to peracetic acid. The effect of reaction time on the epoxy group content was measured during the epoxidation process. The prepared alkyd resins were analyzed by IR and H 1 NMR. The metal coated film properties of epoxidized alkyd resins were compared with those of unmodified alkyd resins. It was observed that the coating films of epoxidized alkyd resins have better in drying properties, hardness, adhesion, impact and flexibility than those of un epoxidized alkyd resins. The flammability properties of the paper coated films for the prepared brominated epoxidized alkyd resins were found to be fire retardant

  16. 21 CFR 177.1655 - Polysulfone resins.

    Science.gov (United States)

    2010-04-01

    ... disodium salt of 4,4′-isopropylidenediphenol is made to react with 4,4′-dichlorodiphenyl sulfone in such a... Limitations Dimethyl sulfoxide Not to exceed 50 parts per million as residual solvent in finished basic resin... residual solvent in finished basic resin in paragraph (a)(1) of this section. N-methyl-2-pyrrolidone Not to...

  17. 21 CFR 177.1580 - Polycarbonate resins.

    Science.gov (United States)

    2010-04-01

    ...′-iso-propylidenediphenol with molten diphenyl carbonate in the presence of the disodium salt of 4,4... chloride Monochlorobenzene Not to exceed 500 p.p.m. as residual solvent in finished resin. Pentaerythritol...-88-3) Not to exceed 800 parts per million as residual solvent in finished resin. Triethylamine (c...

  18. 21 CFR 177.1595 - Polyetherimide resin.

    Science.gov (United States)

    2010-04-01

    ... polyetherimide resin identified in this section may be safely used as an article or component of an article... substances required in the production of basic resins or finished food-contact articles. The optional... and Applied Nutrition (HFS-200), Food and Drug Administration, 5100 Paint Branch Pkwy., College Park...

  19. 21 CFR 177.2440 - Polyethersulfone resins.

    Science.gov (United States)

    2010-04-01

    ... Components of Articles Intended for Repeated Use § 177.2440 Polyethersulfone resins. Polyethersulfone resins identified in paragraph (a) of this section may be safely used as articles or components of articles intended... Petition Control (HFS-215), Center for Food Safety and Applied Nutrition, 1110 Vermont Ave. NW., suite 1200...

  20. Modified resins for solid-phase extraction

    Science.gov (United States)

    Fritz, James S.; Sun, Jeffrey J.

    1991-12-10

    A process of treating aqueous solutions to remove organic solute contaminants by contacting an aqueous solution containing polar organic solute contaminants with a functionalized polystyrene-divinyl benzene adsorbent resin, with the functionalization of said resin being accomplished by organic hydrophilic groups such as hydroxymethyl, acetyl and cyanomethyl.

  1. Measurement of opalescence of resin composites.

    Science.gov (United States)

    Lee, Yong-Keun; Lu, Huan; Powers, John M

    2005-11-01

    Opalescence is an optical property, where there is light scattering of the shorter wavelengths of the visible spectrum, giving the material a bluish appearance under reflected light and an orange/brown appearance under transmitted light. The objective of this study was to determine the opalescence of resin composites with a color measuring spectrophotometer. Colors of A2 and enamel or translucent shades of four resin composites and of an unfilled resin measured in the reflectance and transmittance modes were compared, and the opalescence parameter (OP) was calculated as the difference in blue-yellow coordinate (Deltab*) and red-green parameter (Deltaa*) between the reflected and transmitted colors of 1-mm thick specimens. The masking effect was calculated as the color difference between the color of a black background and the color of specimen over the black background. The range of OP in resin composites was 5.7-23.7, which was higher than that of the unfilled resin. However, there were significant differences among the brands and shades of the resin composites. Opalescence varied by brand and shade of the resin composites, and contributed to the masking of background color along with translucency parameter. Some of the resin composites actually displayed opalescence.

  2. On the real performance of cation exchange resins in wastewater treatment under conditions of cation competition: the case of heavy metal pollution.

    Science.gov (United States)

    Prelot, Benedicte; Ayed, Imen; Marchandeau, Franck; Zajac, Jerzy

    2014-01-01

    Sorption performance of cation-exchange resins Amberlite® IRN77 and Amberlite™ IRN9652 toward Cs(I) and Sr(II) has been tested in single-component aqueous solutions and simulated waste effluents containing other monovalent (Effluent 1) or divalent (Effluent 2) metal cations, as well as nitrate, borate, or carbonate anions. The individual sorption isotherms of each main component were measured by the solution depletion method. The differential molar enthalpy changes accompanying the ion-exchange between Cs+ or Sr2+ ions and protons at the resin surface from single-component nitrate solutions were measured by isothermal titration calorimetry and they showed a higher specificity of the two resins toward cesium. Compared to the retention limits of both resins under such idealized conditions, an important depression in the maximum adsorption capacity toward each main component was observed in multication systems. The overall effect of ion exchange process appeared to be an unpredictable outcome of the individual sorption capacities of the two resins toward various cations as a function of the cation charge, size, and concentration. The cesium retention capacity of the resins was diminished to about 25% of the "ideal" value in Effluent 1 and 50% in Effluent 2; a further decrease to about 15% was observed upon concomitant strontium addition. The uptake of strontium by the resins was found to be less sensitive to the addition of other metal components: the greatest decrease in the amount adsorbed was 60% of the ideal value in the two effluents for Amberlite® IRN77 and 75% for Amberlite™ IRN9652. It was therefore demonstrated that any performance tests carried out under idealized conditions should be exploited with much caution to predict the real performance of cation exchange resins under conditions of cation competition.

  3. Embedding of reactor wastes in plastic resins

    International Nuclear Information System (INIS)

    1979-01-01

    STEAG Kernenergie GmbH is so far the only firm commercially to condition radioactive bead ion exchange resins by embedding in polystyrene resins. The objective of the work reported here was to study and develop methods for immobilization of other reactor wastes in plastic resins. Comparison studies on high quality cement however showed favourable results for cement with respect to process safety and economy. For this reason STEAG interrupted its work in the field of resin embedding after about one year. The work carried out during this period is surveyed in this report, which includes a comprehensive literature study on reactor wastes and their solidification in plastic resins as well as on regulations with regard to radioactive waste disposal in the member states of the European Communities

  4. Chemoviscosity modeling for thermosetting resins, 2

    Science.gov (United States)

    Hou, T. H.

    1985-01-01

    A new analytical model for simulating chemoviscosity of thermosetting resin was formulated. The model is developed by modifying the Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By assuming a linear relationship between the glass transition temperature and the degree of cure of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature dependent functions of the modified WLF theory constants were determined from the isothermal cure data of Lee, Loos, and Springer for the Hercules 3501-6 resin system. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data reported by Carpenter. A chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformations of the thermosetting resin systems during cure was established.

  5. Electrodialytic decontamination of spent ion exchange resins

    International Nuclear Information System (INIS)

    Nott, B.R.

    1982-01-01

    Development of a novel electrodialytic decontamination process for the selective removal of radioactive Cs from spent ion exchange resins containing large amounts of Li is described. The process involves passage of a dc electric current through a bed of the spent ion exchange resin in a specially designed electrodialytic cell. The radiocesium so removed from a volume of the spent resin is concentrated onto a much smaller volume of a Cs selective sorbent to achieve a significant radioactive waste volume reduction. Technical feasibility of the electrodialytic resin decontamination process has been demonstrated on a bench scale with a batch of simulated spent ion exchange resin and using potassium cobalt ferrocyanide as the Cs selective sorbent. A volume reduction factor between 10 and 17 has been estimated. The process appears to be economically attractive. Improvements in process economics can be expected from optimization of the process. Other possible applications of the EDRD process have been identified

  6. Solidification of ion exchange resin wastes

    International Nuclear Information System (INIS)

    1982-08-01

    Solidification media investigated included portland type I, portland type III and high alumina cements, a proprietary gypsum-based polymer modified cement, and a vinyl ester-styrene thermosetting plastic. Samples formulated with hydraulic cement were analyzed to investigate the effects of resin type, resin loading, waste-to-cement ratio, and water-to-cement ratio. The solidification of cation resin wastes with portland cement was characterized by excessive swelling and cracking of waste forms, both after curing and during immersion testing. Mixed bed resin waste formulations were limited by their cation component. Additives to improve the mechanical properties of portland cement-ion exchange resin waste forms were evaluated. High alumina cement formulations dislayed a resistance to deterioration of mechanical integrity during immersion testing, thus providing a significant advantage over portland cements for the solidification of resin wastes. Properties of cement-ion exchange resin waste forms were examined. An experiment was conducted to study the leachability of 137 Cs, 85 Sr, and 60 Co from resins modified in portland type III and high alumina cements. The cumulative 137 Cs fraction release was at least an order of magnitude greater than that of either 85 Sr or 60 Co. Release rates of 137 Cs in high alumina cement were greater than those in portland III cement by a factor of two.Compressive strength and leach testing were conducted for resin wastes solidified with polymer-modified gypsum based cement. 137 Cs, 85 Sr, and 60 Co fraction releases were about one, two and three orders of magnitude higher, respectively, than in equivalent portland type III cement formulations. As much as 28.6 wt % dry ion exchange resin was successfully solidified using vinyl ester-styrene compared with a maximum of 25 wt % in both portland and gypsum-based cement

  7. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    Science.gov (United States)

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  8. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  9. Oxygen titration strategies in chronic neonatal lung disease.

    Science.gov (United States)

    Primhak, Robert

    2010-09-01

    The history of oxygen therapy in neonatology has been littered with error. Controversies remain in a number of areas of oxygen therapy, including targets and strategies in supplemental oxygen therapy in Chronic Neonatal Lung Disease (CNLD). This article reviews some of these controversies, and makes some recommendations based on the available evidence. In graduates of neonatal units who are left with CNLD, oxygen saturation should be kept above 93-95%, with levels below 90% being avoided as far as possible. Titration of oxygen should be done using oximetry recordings which include periods of different activities. Weaning of oxygen supplementation should only be done based on satisfactory recordings during a trial of a lower flow. There is insufficient evidence to say whether weaning for increasing hours a day or stepwise weaning to a continuous lower flow is a better method. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Sailing on the "C": A Vitamin Titration with a Twist

    Science.gov (United States)

    Sowa, S.; Kondo, A. E.

    2003-05-01

    The experiment takes the traditional redox titration of vitamin C using iodine with starch as an indicator, and presents it to the student as a challenge in guided-inquiry format. Two versions, with different levels of difficulty, are provided, to accommodate students with varying levels of problem-solving skills. The "challenge" is both quantitative and qualitative: if you were an eighteenth-century sea captain packing for a voyage to the New World, would you take oranges, lemons, limes, or grapefruits to prevent your crew from getting scurvy? The challenge ties in history, nutrition, and health with chemistry, and provides students an opportunity to work with familiar food products in the laboratory.

  11. Ultrasonic and densimetric titration applied for acid-base reactions.

    Science.gov (United States)

    Burakowski, Andrzej; Gliński, Jacek

    2014-01-01

    Classical acoustic acid-base titration was monitored using sound speed and density measurements. Plots of these parameters, as well as of the adiabatic compressibility coefficient calculated from them, exhibit changes with the volume of added titrant. Compressibility changes can be explained and quantitatively predicted theoretically in terms of Pasynski theory of non-compressible hydrates combined with that of the additivity of the hydration numbers with the amount and type of ions and molecules present in solution. It also seems that this development could be applied in chemical engineering for monitoring the course of chemical processes, since the applied experimental methods can be carried out almost independently on the medium under test (harmful, aggressive, etc.).

  12. Potentiometric and amperometric titration of ferrocene by cerium(4)

    International Nuclear Information System (INIS)

    Solomatin, V.T.

    1985-01-01

    Redox-potentials (E) of ferrocene (ferricenium-cation), Ce(4)/Ce(3) pairs are investigated and a possibility of regulating E value of these systems depending on the composition of water-organic media is shown. E value of Ce(4)/Ce(3) system decreases as increasing H 2 SO 4 concentration and CH 3 COOH mol share in the water-organic phase. Kinetic investigations of Ce(4)-ferrocene reactions shown that E constant value is achieved in 12-16 s depending on donor-acceptor properties of the solvent. Optimum conditions are chosen for potentiometric and amperometric titration of ferrocene by ceruium (4) in technological products. The method is versatile and permits to determine from tenths to dozens per cent of ferrocene

  13. MZC Gel Inhibits SHIV-RT and HSV-2 in Macaque Vaginal Mucosa and SHIV-RT in Rectal Mucosa.

    Science.gov (United States)

    Calenda, Giulia; Villegas, Guillermo; Barnable, Patrick; Litterst, Claudia; Levendosky, Keith; Gettie, Agegnehu; Cooney, Michael L; Blanchard, James; Fernández-Romero, José A; Zydowsky, Thomas M; Teleshova, Natalia

    2017-03-01

    The Population Council's microbicide gel MZC (also known as PC-1005) containing MIV-150 and zinc acetate dihydrate (ZA) in carrageenan (CG) has shown promise as a broad-spectrum microbicide against HIV, herpes simplex virus (HSV), and human papillomavirus. Previous data show antiviral activity against these viruses in cell-based assays, prevention of vaginal and rectal simian-human immunodeficiency virus reverse transcriptase (SHIV-RT) infection, and reduction of vaginal HSV shedding in rhesus macaques and also excellent antiviral activity against HSV and human papillomavirus in murine models. Recently, we demonstrated that MZC is safe and effective against SHIV-RT in macaque vaginal explants. Here we established models of ex vivo SHIV-RT/HSV-2 coinfection of vaginal mucosa and SHIV-RT infection of rectal mucosa in macaques (challenge of rectal mucosa with HSV-2 did not result in reproducible tissue infection), evaluated antiviral activity of MZC, and compared quantitative polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay readouts for monitoring SHIV-RT infection. MZC (at nontoxic dilutions) significantly inhibited SHIV-RT in vaginal and rectal mucosas and HSV-2 in vaginal mucosa when present during viral challenge. Analysis of SHIV-RT infection and MZC activity by 1-step simian immunodeficiency virus gag quantitative RT-PCR and p27 enzyme-linked immunosorbent assay demonstrated similar virus growth dynamics and MZC activity by both methods and higher sensitivity of quantitative RT-PCR. Our data provide more evidence that MZC is a promising dual compartment multipurpose prevention technology candidate.

  14. Use of quantitative real-time RT-PCR to investigate the correlation between viremia and viral shedding of canine distemper virus, and infection outcomes in experimentally infected dogs.

    Science.gov (United States)

    Sehata, Go; Sato, Hiroaki; Ito, Toshihiro; Imaizumi, Yoshitaka; Noro, Taichi; Oishi, Eiji

    2015-07-01

    We used real-time RT-PCR and virus titration to examine canine distemper virus (CDV) kinetics in peripheral blood and rectal and nasal secretions from 12 experimentally infected dogs. Real-time RT-PCR proved extremely sensitive, and the correlation between the two methods for rectal and nasal (r=0.78, 0.80) samples on the peak day of viral RNA was good. Although the dogs showed diverse symptoms, viral RNA kinetics were similar; the peak of viral RNA in the symptomatic dogs was consistent with the onset of symptoms. These results indicate that real-time RT-PCR is sufficiently sensitive to monitor CDV replication in experimentally infected dogs regardless of the degree of clinical manifestation and suggest that the peak of viral RNA reflects active CDV replication.

  15. rt, Arvo: "Miserere", "Festina lente" / Volkmar Fischer

    Index Scriptorium Estoniae

    Fischer, Volkmar

    1991-01-01

    Uuest heliplaadist Pärt, Arvo: "Miserere", "Festina lente", "Sarah Was Ninety Years Old". The Hilliard Ensemble. Orchester der Beethovenhalle Bonn. Dirigent Dennis Russel Davies (ECM Records, distr Amigo)

  16. rt, Arvo: Seven Magnificat Antiphons / Barry Witherden

    Index Scriptorium Estoniae

    Witherden, Barry

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: Seven Magnificat Antiphons. Magnificat. Summa; Tormis, Veljo: The Curse Upon Iron. Karelian Destiny. BBC Singers, Bo Holton". Collins Classics 1472-2 (61 minutes: DDD)

  17. Reverse transcriptase-quantitative polymerase chain reaction (RT ...

    African Journals Online (AJOL)

    zino

    2014-02-05

    Feb 5, 2014 ... ecological studies - A review ... The objective of this review is to assess the importance of RT-qPCR in soil related ... phenol extraction step with heat inactivation of the added .... Real time polymerase chain reaction (PCR).

  18. rt, Arvo. Litany; Psalom; Trisagion / Andreas Obst

    Index Scriptorium Estoniae

    Obst, Andreas

    1996-01-01

    rt, Arvo. Litany; Psalom; Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste; Lithuanian Chamber Orchestra, Saulius Sondeckis. ECM 1592/449 810-2

  19. rt, Arvo: Litany. Psalom. Trisagion / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1996-01-01

    Uuest heliplaadist "Pärt, Arvo: Litany. Psalom. Trisagion. Hilliard Ensemble, Estonian Philharmonic Chamber Choir, Tallinn Chamber Orchestra, Tõnu Kaljuste; Lithuanian Chamber Orchestra, Saulius Sondeckis" ECM New Series 449 810-4; 449 810-2 (42 minutes: DDD)

  20. rt, Arvo: "Beatus". Statuit ei Dominus / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1997-01-01

    Uuest heliplaadist "Pärt, Arvo: "Beatus". Statuit ei Dominus. Missa syllabica. Beatus Petronius. 7 Magnificat-Antiphonen. De profundis. Memento. Cantate Domino. Solfeggio. Estonian Philharmonic Chamber Choir, T. Kaljuste". Virgin Classics 545 276-2 (CD:167F)

  1. The value of research : telling the R&T story

    Science.gov (United States)

    2009-07-01

    The Federal Highway Administration (FHWA) plays a leadership role in shaping and executing a National Research and Technology (R&T) program. The agency also acts as a convener; collaborations with State, industry, and academic partners provide the fo...

  2. Milan Kundera poeediparukaga faun / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    1996-01-01

    Arvustus: Kundera, Milan. Surematus. Tln. : Monokkel, 1995. Ilmunud ka kogumikus: Hellerma, Kärt. Kohanenud kirjandus : valik kirjanduskriitikat 1987-2006. Eesti Keele Sihtasutus : Tallinn, 2006. Lk. 176-179

  3. EPICOR-II resin degradation results from first resin samples of PF-8 and PF-20

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Sanders, R.D. Sr.

    1985-12-01

    The 28 March 1979 accident at Three Mile Island Unit 2 released approximately 560,000 gallons of contaminated water to the Auxiliary and Fuel Handling Buildings. The water was decontaminated using a demineralization system called EPICOR-II developed by Epicor, Inc. The Low-Level Waste Data Base Development - EPICOR-II Resin/Liner Investigation Project is studying the chemical and physical conditions of the synthetic ion exchange resins found in several EPICOR-II prefilters. This report summarizes results and analyses of the first sampling of ion exchange resins from EPICOR-II prefilters PE-8 and -20. Results are compared with baseline data from tests performed on unirradiated Epicor, Inc. resins to determine if degradation has occurred due to the high internal radiation dose received by the EPICOR-II resins. Results also are compared with recent findings on resin degradation by Battelle Columbus Laboratories and Brookhaven National Laboratory. Analyses comparing test results of resins from EPICOR-II prefilters PF-8 and -20 with unirradiated resins obtained from Epicor, Inc. show resin degradation has occurred in some of the EPICOR-II resins examined. The mechanism of degradation is compared with work of other researchers and is consistent with their findings. The strong acid cation resins (divinylbenzene, styrene base structure) are losing effective cross-linking along with scission of functional groups and are experiencing first an increase and eventually a decrease in total exchange capacity as the absorbed radiation dose increases. The phenolic cation resins (phenol-formaldehyde base structure) show a loss of effective cross-linking and oxidation of the polymer chain. Analyses of resins removed from EPICOR-II prefilters PF-8 and -20 over the next several years should show a further increase in degradation

  4. flower extract as an improvised indicator in acid – base titration

    African Journals Online (AJOL)

    USER

    laboratory practical with an instructional material that is useful, economical, simple and accurate for the said titration. Therefore, it is recommended for integrated science and chemistry instructions. Keywords: Flower, acid, base, indicator, titration. INTRODUCTION. In Nigeria, factors militating against science education.

  5. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  6. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    Science.gov (United States)

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  7. The ion-sensitive field effect transistor in rapid acid-base titrations

    NARCIS (Netherlands)

    Bos, M.; Bergveld, Piet; van Veen-Blaauw, A.M.W.

    1979-01-01

    Ion-sensitive field effect transistors (ISFETs) are used as the pH sensor in rapid acid—base titrations. Titration speeds at least five times greater than those with glass electrodes are possible for accuracies better than ±1%.

  8. A knowledge based advisory system for acid/base titrations in non-aqueous solvents

    NARCIS (Netherlands)

    Bos, M.; van der Linden, W.E.

    1996-01-01

    A computer program was developed that could advice on the choice of solvent and titrant for acid/base titrations in nonaqueous media. It is shown that the feasibility of a titration in a given solvent can be calculated from solvent properties and intrinsic acid/base properties of the sample

  9. Quick titration of pergolide in cotreatment with domperidone is safe and effective

    NARCIS (Netherlands)

    Jansen, PAF; Herings, RMC; Samson, MM; Schuurmans-Daemen, LMPJ; Hovestadt, A; Verhaar, HJJ; Van Laar, T; de Vreede, P.

    2001-01-01

    The purpose of the study was to analyze efficacy and safety of quick pergolide titration combined with domperidone. In an open-label prospective study, pergolide was titrated in 16 days to a maximum of 3 mg/d doses as adjunctive treatment to L-Dopa in 10 elderly patients with Parkinson's disease.

  10. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    Science.gov (United States)

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  11. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    Science.gov (United States)

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P CPAP titration level (P CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  12. Kuidas sünnib pealkiri? / Pärt Lias

    Index Scriptorium Estoniae

    Lias, Pärt

    2003-01-01

    Eesti kirjanikud vastavad Pärt Liase küsimusele oma teoste pealkirjade saamisloo kohta: Doris Kareva, Ilona Laaman, Eha Lättemäe, Priidu Beier, Oskar Kruus, Jaan Kruusvall, Paul-Eerik Rummo ja Andres Vanapa (1); Triin Soomets, Priit Aimla, Aarne Puu, Einar Sander, Jüri Tuulik ja Ülo Tuulik (2); Nikolai Baturin, Leo Metsar, Toomas Vint, Leonid Stolovitš ja Pärt Lias (3)

  13. Decomposing method for ion exchange resin

    International Nuclear Information System (INIS)

    Sako, Takeshi; Sato, Shinshi; Akai, Yoshie; Moniwa, Shinobu; Yamada, Kazuo

    1998-01-01

    The present invention concerns a method of decomposing ion exchange resins generated in a nuclear power plant to carbon dioxide reliably in a short period of time. (1) The ion exchange resins are mixed with water, and then they are kept for a predetermined period of time in the presence of an inert gas at high temperature and high pressure exceeding the critical point of water to decompose the ion exchange resins. (2) The ion exchange resins is mixed with water, an oxidant is added and they are kept for a predetermined time in the presence of an inert gas at a high temperature and a high pressure exceeding a critical point of water of an inert gas at a high temperature to decompose the ion exchange resins. (3) An alkali or acid is added to ion exchange resins and water to control the hydrogen ion concentration in the solution and the ion exchange resins are decomposed in above-mentioned (1) or (2). Sodium hydroxide is used as the alkali and hydrochloric acid is used as the acid. In addition, oxygen, hydrogen peroxide or ozone is used as an oxidant. (I.S.)

  14. Hyperthermic Fibrinolysis with rt-PA: In Vitro Results

    International Nuclear Information System (INIS)

    Schwarzenberg, Helmut; Mueller-Huelsbeck, Stefan; Brossman, Joachim; Christian Glueer, Claus; Bruhn, Hans Dieter; Heller, Martin

    1998-01-01

    Purpose: To investigate the influence of hyperthermia up to 45 deg. C on fibrinolysis with recombinant tissue-type plasminogen activator (rt-PA). Methods: Standardized fibrin clots were incubated in a water bath for 5 hr with either rt-PA (test group) or 0.9% sodium chloride (control group) and blood plasma at temperatures of 30-45 deg. C. Concentrations of D-dimer and time to complete clot lysis were measured.Results: The activity of fibrinolysis with rt-PA rose with increasing temperature: time to lysis approximately halved from 30 deg. C to 40 deg. C and the concentration of D-dimer tripled. In the control group clot size did not change.Conclusions: Activity of rt-PA-induced fibrinolysis rises distinctly with higher temperatures. Since even healthy subjects show a physiologic decline in body temperature in the extremities, in patients with occlusive arterial disease decreased activity of fibrinolysis with rt-PA can be expected. Controlled hyperthermia may improve fibrinolysis with rt-PA and should be investigated in vivo

  15. Safety evaluation of cation-exchange resins

    International Nuclear Information System (INIS)

    Kalkwarf, D.R.

    1977-08-01

    Results are presented of a study to evaluate whether sufficient information is available to establish conservative limits for the safe use of cation-exchange resins in separating radionuclides and, if not, to recommend what new data should be acquired. The study was also an attempt to identify in-line analytical techniques for the evaluation of resin degradation during radionuclide processing. The report is based upon a review of the published literature and upon discussions with many people engaged in the use of these resins. It was concluded that the chief hazard in the use of cation-exchange resins for separating radionuclides is a thermal explosion if nitric acid or other strong oxidants are present in the process solution. Thermal explosions can be avoided by limiting process parameters so that the rates of heat and gas generation in the system do not exceed the rates for their transfer to the surroundings. Such parameters include temperature, oxidant concentration, the amounts of possible catalysts, the radiation dose absorbed by the resin and the diameter of the resin column. Current information is not sufficient to define safe upper limits for these parameters. They can be evaluated, however, from equations derived from the Frank-Kamenetskii theory of thermal explosions provided the heat capacities, thermal conductivities and rates of heat evolution in the relevant resin-oxidant mixtures are known. It is recommended that such measurements be made and the appropriate limits be evaluated. A list of additional safety precautions are also presented to aid in the application of these limits and to provide additional margins of safety. In-line evaluation of resin degradation to assess its safety hazard is considered impractical. Rather, it is recommended that the resin be removed from use before it has received the limiting radiation dose, evaluated as described above

  16. SPECIAL CONSIDERATIONS REGARDING WARFARIN DOSE TITRATION IN PATIENTS WITH ATRIAL FIBRILLATION DEPENDING ON CLINICAL FACTORS

    Directory of Open Access Journals (Sweden)

    E. L. Artanova

    2011-01-01

    Full Text Available Aim. To study the relations of clinical characteristics and individual warfarin dose titration in patients with atrial fibrillation. Material and methods. Period of warfarin dose titration was analyzed in 68 patients with atrial fibrillation due to ischemic heart disease. Adjusted warfarin dose in milligram, duration of dose titration in days and maximal international normalized ratio (INR were taken into account. Sex, age, history of myocardial infarction and stroke, concomitant diseases, amiodarone therapy were considered among clinical characteristics. Results. Adjusted warfarin dose was significantly higher in obesity , and it was lower in case of experienced myocardial infarction. The INR highest levels and maximal amplitudes of its fluctuations were observed in patients with thyroid gland nodes and smokers. Period of warfarin dose titration was longer in patients treated with amiodarone. Conclusion. Warfarin dose titration in patients with atrial fibrillation depends on the presence of myocardial infarction, obesity , thyroid nodular changes, smoking and amiodarone treatment.

  17. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  18. Molybdenum (6) determination by the method of high-frequency and pH titration

    International Nuclear Information System (INIS)

    Lukianets, I.G.; Kulish, N.G.

    1981-01-01

    A possibility to determine Mo(6) using the method of high frequency and pH-metric titration is investigated. By means of the high frequency contact R-cell Mo(6) titration is performed using different precipitators: 8-oxiquinoline, lead nitrate and acetate and silver nitrate. It is established that the best conditions are achieved during titration of 67.2-1343 mg/10 ml Mo(6) with lead acetate (pH 4.5-6.5). Relative standard deviation Ssub(r) constitutes 0.005 pH-metric titration of Mo(6) with complexone 3 is studied. The range of Mo(6) concentrations determined constitutes 13.43-134.3 mg at pH initial value of 3.5-5.5. Relative standard deviation Ssub(r) constitutes 0.003. Techniques of molybdenum determination in ferromolybdenum using the method of high frequency and pH-metric titration are developed [ru

  19. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    Science.gov (United States)

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  20. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    Directory of Open Access Journals (Sweden)

    Eva Tavčar

    2012-01-01

    Full Text Available The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD=4.3%, accuracy, and linearity (2=0.997.

  1. Simple modification of karl-Fischer titration method for determination of water content in colored samples.

    Science.gov (United States)

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R(2) = 0.997).

  2. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    Directory of Open Access Journals (Sweden)

    Jian-Qiang Hu

    2017-01-01

    Full Text Available Water content in jet fuels is detected by thermometric titration (TMT, and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicated spiked water contents. The obtained results between TMT and Karl Fischer titration have been proven to be in accord. But, the duration of titration merely spends 3–5 min in the whole process, greatly shortening the detected time. Therefore, rapid and accurate determination of trace water in a jet fuel can be realized by TMT.

  3. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...... Class II, 4 SDR-CeramX mono+ and 6 CeramXmono+-only restorations. The main reasons for failurewere tooth fracture (6) and secondary caries (4). The annual failure rate (AFR) for all restorations (Class I and II) was for the bulk-filled-1.1% and for the resin composite-only restorations 1...

  4. Immobilisation of ion exchange resins in cement

    International Nuclear Information System (INIS)

    Howard, C.G.; Jolliffe, C.B.; Lee, D.J.

    1990-09-01

    The removal of activity from spent decontaminating solutions eg LOMI can be achieved using organic ion exchange resins. These resins can be successfully immobilised in cement based matrices. The optimum cement system contained 10% ordinary Portland cement 84% gg blast furnace slag, 6% microsilica with a water cement ratio of 0.5 and a dry resin loading of 36% with respect to total weight. This formulation was successfully scaled up to 200 litres giving a product with acceptable compressive strength, dimensional stability and elastic modulus. Storage of samples under water appears to have no detrimental effects on the product's properties. (author)

  5. Immobilisation of ion exchange resins in cement

    International Nuclear Information System (INIS)

    Howard, C.G.; Jolliffe, C.B.; Lee, D.J.

    1990-09-01

    The removal of activity from spent decontaminating solutions eg LOMI can be achieved using organic ion exchange resins. These resins can be successfully immobilised in cement based matrices. The optimum cement system contained 10% ordinary Portland cement, 84% gg blast furnace slag, 6% microsilica with a water cement ratio of 0.5 and a dry resin loading of 36% with respect to total weight. This formulation was successfully scaled up to 200 litres giving a product with acceptable compressive strength, dimensional stability and elastic modulus. Storage of samples under water appears to have no detrimental effects on the products' properties. (author)

  6. Thermosetting resins for nuclear track detection

    International Nuclear Information System (INIS)

    Fujii, M.

    1985-01-01

    Several new thermosetting resins with a three dimensional network structure like CR-39 were polymerized to study their characteristics for use as nuclear track detectors. During the course of this study, thermosetting resins with good etching properties and various sensitivities have been obtained. The comparison of the molecular structures of these resins gives up an important clue for the development of highly sensitive polymeric track detectors. They will also be useful for observations of ultra-heavy cosmic rays and heavily ionizing particles at low energies. (orig.)

  7. Thermosetting resins for nuclear track detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Yokota, Rikio

    1985-01-01

    Several new thermosetting resins with a three dimensional network structure like CR-39 were polymerized to study their characteristics for use as nuclear track detectors. During the course of this study, thermosetting resins with good etching properties and various sensitivities have been obtained. The comparison of the molecular structures of these resins gives us an important clue for the development of highly sensitive polymeric track detectors. They will also be useful for observations of ultra-heavy cosmic rays and heavily ionizing particles at low energies. (author)

  8. Incineration of ion-exchange resins

    International Nuclear Information System (INIS)

    Valkiainen, M.; Nykyri, M.

    1985-01-01

    Incineration of ion-exchange resins in a fluidized bed was studied on a pilot plant scale at the Technical Research Centre of Finland. Both granular and powdered resins were incinerated in dry and slurry form. Different bed materials were used in order to trap as much cesium and cobalt (inactive tracers) as possible in the bed. Also the sintering of the bed materials was studied in the presence of sodium. When immobilized with cement the volume of ash-concrete is 4 to 22% of the concrete of equal compressive strength acquired by direct solidification. Two examples of multi-purpose equipment capable of incinerating ion-exchange resins are presented. (orig.)

  9. SEM and elemental analysis of composite resins

    International Nuclear Information System (INIS)

    Hosoda, H.; Yamada, T.; Inokoshi, S.

    1990-01-01

    Twenty-four chemically cured, 21 light-cured anterior, three light-cured anterior/posterior, and 18 light-cured posterior composite resins were examined using scanning electron microscopy, and the elemental composition of their filler particles was analyzed with an energy dispersive electron probe microanalyzer. According to the results obtained, the composite resins were divided into five groups (traditional, microfilled type, submicrofilled type, hybrid type, and semihybrid), with two additional hypothetical categories (microfilled and hybrid). Characteristics of each type were described with clinical indications for selective guidance of respective composite resins for clinical use

  10. Macromolecular competition titration method accessing thermodynamics of the unmodified macromolecule-ligand interactions through spectroscopic titrations of fluorescent analogs.

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand-macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein-nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein-nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein-nucleic acid interactions, it can generally be applied to any ligand-macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Macromolecular Competition Titration Method: Accessing Thermodynamics of the Unmodified Macromolecule–Ligand Interactions Through Spectroscopic Titrations of Fluorescent Analogs

    Science.gov (United States)

    Bujalowski, Wlodzimierz; Jezewska, Maria J.

    2011-01-01

    Analysis of thermodynamically rigorous binding isotherms provides fundamental information about the energetics of the ligand–macromolecule interactions and often an invaluable insight about the structure of the formed complexes. The Macromolecular Competition Titration (MCT) method enables one to quantitatively obtain interaction parameters of protein–nucleic acid interactions, which may not be available by other methods, particularly for the unmodified long polymer lattices and specific nucleic acid substrates, if the binding is not accompanied by adequate spectroscopic signal changes. The method can be applied using different fluorescent nucleic acids or fluorophores, although the etheno-derivatives of nucleic acid are especially suitable as they are relatively easy to prepare, have significant blue fluorescence, their excitation band lies far from the protein absorption spectrum, and the modification eliminates the possibility of base pairing with other nucleic acids. The MCT method is not limited to the specific size of the reference nucleic acid. Particularly, a simple analysis of the competition titration experiments is described in which the fluorescent, short fragment of nucleic acid, spanning the exact site-size of the protein–nucleic acid complex, and binding with only a 1:1 stoichiometry to the protein, is used as a reference macromolecule. Although the MCT method is predominantly discussed as applied to studying protein–nucleic acid interactions, it can generally be applied to any ligand–macromolecule system by monitoring the association reaction using the spectroscopic signal originating from the reference macromolecule in the presence of the competing macromolecule, whose interaction parameters with the ligand are to be determined. PMID:21195223

  12. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-III Presentation of a fully automatic titration apparatus and of results supporting the theories given in the preceding parts.

    Science.gov (United States)

    Pehrsson, L; Ingman, F

    1977-02-01

    This paper forms Part III of a series in which the first two parts describe methods for evaluating titrations performed by stepwise addition of equal volumes of titrant. The great advantage of these methods is that they do not require an accurate calibration of the electrode system. This property makes the methods very suitable for routine work. e.g., in automatic analysis. An apparatus for performing such titrations automatically is presented. Further, results of titrations of monoprotic acids, a diprotic acid, an ampholyte, a mixture of an acid with its conjugate base, and mixtures of two acids with a small difference between the stability constants are given. Most of these titrations cannot be evaluated by the Gran or Hofstee methods but yield results having errors of the order of 0.1% if the methods proposed in Parts I and II of this series are employed. The advantages of the method of stepwise addition of equal volumes of titrant combined with the proposed evaluation methods, in comparison with common methods such as titration to a preset pH, are that all the data are used in the evaluation, permitting a statistical treatment and giving better possibilities for tracing systematic errors.

  13. Thermosetting behavior of pitch-resin from heavy residue

    Energy Technology Data Exchange (ETDEWEB)

    Qingfang, Z.; Yansheng, G.; Baohua, H.; Yuzhen, Z. [China Univ. of Petroleum, Dongying, Shandong (China). State Key LAboratory of Heavy Oil Processing, Heavy Oil Research Inst.

    2006-07-01

    Thermosetting resins are widely employed as a basic matrix for c/c composites in carbon materials production. A new type of synthesized thermosetting resin is called pitch resin. Pitch resin is a cheaper resin and possesses a potential opportunity for future use. However, the thermosetting behavior of pitch resin is not very clear. The hardening process and conditions for thermosetting are very important for future use of pitch resin. B-stage pitch resin is a soluble and meltable inter-media condensed polymer, which is not fully reacted and is of a low molecular weight. The insoluble and unmelted pitch resin can only be obtained from synthesized B-stage resin after a hardening stage. This paper presented an experiment that synthesized B-stage pitch resin with a link agent (PXG) under catalyst action from fluid catalytic cracking (FCC) of the slurry's aromatic enriched component (FCCDF). The paper discussed the experiment, including the synthesis of pitch resin and thermosetting of pitch resin. Two kinds of thermosetting procedures were used in the study called one-step thermosetting and two-step thermosetting. It was concluded that the B-stage pitch resin could be hardened after a thermosetting procedure by heat treatment. The thermosetting pitch resin from 2-step thermosetting possesses was found to have better thermal resistant properties than that of the 1-step thermosetting pitch resin. 13 refs., 2 tabs., 6 figs.

  14. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    Science.gov (United States)

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  15. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    Science.gov (United States)

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  16. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    Science.gov (United States)

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  17. Potentiometric titrations of molybdenum and vanadium in aqueous and mixed so lvents

    International Nuclear Information System (INIS)

    Das, S.K.; Dhaneshwar, R.G.

    1990-01-01

    Potentiometric titration method was developed for molybdenum, employing different electrode systems. Molybdenum(VI) is reduced to molybdenum(V) by ferrous solution in presence of phosphoric acid and then titrated with potassium dichromate. It was found that ferrous concentration should be five times more than molybdenum and phosphoric acid should be 1.0 ml for 0.1N titration and 0.5 ml for lower concentration titrations. The method is also applicable to vanadium titrations. Employing Au/SCE and Pt/SCE systems, it was observed that generally curve heights obtained for platinum electrode are higher than those for gold electrode. Also for both the electrode systems, the curve heights for vanadium titrations were found to be more than those for molybdenum. Lower limits of titrations for Au/SCE system are 0.01N for molybdenum and 0.0001N for vanadium, whereas for Pt/SCE system, the lower limits obtained were 0.01N for both molybdenum and vanadium titrations. In order to improve the sensitivities of the method, the bimetallic electrode systems Au/Pt and Pt/Au were employed. Au/Pt system was found to give better results than Pt/Au systems. Addition of organic solvent was found to have beneficial effects for titrations of 0.001N and below. Methanol was found to be a better solvent than ethanol. Molybdenum titrations, at 0.0001N level could be performed in methanol with Au/Pt system, which is to b e generally preferred than Pt/Au system. (author). 7 refs., 3 tabs

  18. Condensate-polisher resin-leakage quantification and resin-transport studies

    International Nuclear Information System (INIS)

    Stauffer, C.C.; Doss, P.L.

    1983-04-01

    The objectives of this program were to: (1) determine the extent of resin leakage from current generation condensate polisher systems, both deep bed and powdered resin design, during cut-in, steady-state and flow transient operation, (2) analyze moisture separator drains and other secondary system samples for resin fragments and (3) document the level of organics in the secondary system. Resin leakage samples were obtained from nine-power stations that have either recirculating steam generators or once through steam generators. Secondary system samples were obtained from steam generator feedwater, recirculating steam generator blowdown and moisture separator drains. Analysis included ultraviolet light examination, SEM/EDX, resin quantification and infrared analysis. Data obtained from the various plants were compared and factors affecting resin leakage were summarized

  19. The mechanism of uranium adsorption on Resin 508 and isoelectric point of the resin

    International Nuclear Information System (INIS)

    Han Qingping; Lu Weichang; Su Huijuan; Hu Jinbo; Zhang Liqin; Chen Banglin

    1990-01-01

    The adsorption process of uranium by Resin 508 at the solid-liquid interface was investigated and the mechanism of uranium adsorption including adsorption dynamics, adsorption thermodynamics and isoelectric point of resin was studied. The results are as follows: The maximum of uranium adsorption is attained at pH5-7; Uranium adsorption isotherm by Resin 508 in experimental conditions agrees with Langmuir's adsorption isotherm, the maximum of uranium adsorbed (Vm) is 716 mg U/g-dried resin; The adsorption of uranium by Resin 508 is an endothermic reaction and ΔH = 16.87 kJ/mol; The exchange-adsorption rate is mainly controlled by liquid film diffusion; The isoelectric points of Resin 508 before and after uranium adsorption are found to be pH7.5 and pH5.7 respectively. It is a specific adsorption for uranium

  20. NASA SPoRT GOES-R Proving Ground Activities

    Science.gov (United States)

    Stano, Geoffrey T.; Fuell, Kevin K.; Jedloec, Gary J.

    2010-01-01

    The NASA Short-term Prediction Research and Transition (SPoRT) program is a partner with the GOES-R Proving Ground (PG) helping prepare forecasters understand the unique products to come from the GOES-R instrument suite. SPoRT is working collaboratively with other members of the GOES-R PG team and Algorithm Working Group (AWG) scientists to develop and disseminate a suite of proxy products that address specific forecast problems for the WFOs, Regional and National Support Centers, and other NOAA users. These products draw on SPoRT s expertise with the transition and evaluation of products into operations from the MODIS instrument and the North Alabama Lightning Mapping Array (NALMA). The MODIS instrument serves as an excellent proxy for the Advanced Baseline Imager (ABI) that will be aboard GOES-R. SPoRT has transitioned and evaluated several multi-channel MODIS products. The true and false color products are being used in natural hazard detection by several SPoRT partners to provide better observation of land features, such as fires, smoke plumes, and snow cover. Additionally, many of SPoRT s partners are coastal offices and already benefit from the MODIS sea surface temperature composite. This, along with other surface feature observations will be developed into ABI proxy products for diagnostic use in the forecast process as well as assimilation into forecast models. In addition to the MODIS instrument, the NALMA has proven very valuable to WFOs with access to these total lightning data. These data provide situational awareness and enhanced warning decision making to improve lead times for severe thunderstorm and tornado warnings. One effort by SPoRT scientists includes a lightning threat product to create short-term model forecasts of lightning activity. Additionally, SPoRT is working with the AWG to create GLM proxy data from several of the ground based total lightning networks, such as the NALMA. The evaluation will focus on the vastly improved spatial

  1. 5-year clinical performance of resin composite versus resin modified glass ionomer restorative system in non-carious cervical lesions

    DEFF Research Database (Denmark)

    Franco, Eduardo Batista; Benetti, Ana Raquel; Ishikiriama, Sérgio Kiyoshi

    2006-01-01

    To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions.......To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions....

  2. Nanosilica Modification of Elastomer-Modified VARTM Epoxy Resins for Improved Resin and Composite Toughness

    National Research Council Canada - National Science Library

    Robinette, Jason; Bujanda, Andres; DeSchepper, Daniel; Dibelka, Jessica; Costanzo, Philip; Jensen, Robert; McKnight, Steven

    2007-01-01

    Recent publications have reported a synergy between rubber and silica in modified epoxy resins that results in significantly improved fracture toughness without reductions in other material properties...

  3. Method for regenerating magnetic polyamine-epichlorohydrin resin

    Science.gov (United States)

    Kochen, Robert L.; Navratil, James D.

    1997-07-29

    Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.

  4. A method for producing a hydrocarbon resin

    Energy Technology Data Exchange (ETDEWEB)

    Tsachev, A B; Andonov, K S; Igliyev, S P

    1980-11-25

    Rock coal resin (KS), for instance, with a relative density of 1,150 to 1,190 kilograms per cubic meter, which contains 8 to 10 percent naphthaline, 1.5 to 2.8 percent phenol and 6 to 15 percent substances insoluble in toluene, or its mixture with rock coal or oil fractions of resin are subjected to distillation (Ds) in a pipe furnace with two evaporators (Is) and a distillation tower with a temperature mode in the second stage of 320 to 360 degrees and 290 to 340 degrees in the pitch compartment. A hydrocarbon resin is produced with a high carbon content, especially for the production of resin and dolomite refractory materials, as well as fuel mixtures for blast furnace and open hearth industry.

  5. Synthesis of improved phenolic and polyester resins

    Science.gov (United States)

    Delano, C. B.

    1980-01-01

    Thirty-seven cured phenolic resin compositions were prepared and tested for their ability to provide improved char residues and moisture resistance over state of the art epoxy resin composite matrices. Cyanate, epoxy novolac and vinyl ester resins were investigated. Char promoter additives were found to increase the anaerobic char yield at 800 C of epoxy novolacs and vinyl esters. Moisture resistant cyanate and vinyl ester compositions were investigated as composite matrices with Thornel 300 graphite fiber. A cyanate composite matrix provided state of the art composite mechanical properties before and after humidity exposure and an anaerobic char yield of 46 percent at 800 C. The outstanding moisture resistance of the matrix was not completely realized in the composite. Vinyl ester resins showed promise as candidates for improved composite matrix systems.

  6. Integrating Porous Resins In Enzymatic Processes

    DEFF Research Database (Denmark)

    Al-Haque, Naweed

    . Screening resins for moderately hydrophobic multi-component systems is challenging. Often it is found that the capacity of the resin is inversely related with product selectivity. Therefore a tradeoff has to be made between these parameters which can be crucial from an economic point of view. A low resin...... procedure. The screening therefore becomes a multi-objective task that has to be solved simultaneously. Such an approach has been applied in the method formulated in this framework. To overcome these challenges, different process strategies are required to obtain high yields. A number of different...... inhibition, has gained considerable recognition. The resins act as a reservoir for the inhibitory substrate and a sink for the inhibitory product and simultaneously attain the required high substrate loading to make the process economically feasible. In this way the potential benefit of the enzyme can...

  7. Amine chemistry. Update on impact on resin

    International Nuclear Information System (INIS)

    Bachman, Gregory; Kellogg, Douglas; Wilkes, Marty

    2012-01-01

    Impurity removal in the steam cycle and the associated prevention of corrosion and/or fouling of system components are the goals of ion exchange resins. However, in many instances (such as a switch to amine chemistry or a change in product specifications), resins do not remove, and, in fact, contribute impurities to the steam cycle. This paper reviews recent data compiled to determine the direct and indirect effects of amines on ion exchange resins used in the power industry. Water chemistries have improved in recent years, in large part due to changes in chemistry and resins, but it is necessary to continue to develop products, processes and techniques to reduce impurities and improve overall water chemistry in power plant systems. (orig.)

  8. Amine chemistry. Update on impact on resin

    Energy Technology Data Exchange (ETDEWEB)

    Bachman, Gregory; Kellogg, Douglas [Siemens Industry, Inc., Rockford, IL (United States). Technology and Lab Services; Wilkes, Marty [Siemens Industry, Inc., Rockford, IL (United States). Water Technologies Div.

    2012-03-15

    Impurity removal in the steam cycle and the associated prevention of corrosion and/or fouling of system components are the goals of ion exchange resins. However, in many instances (such as a switch to amine chemistry or a change in product specifications), resins do not remove, and, in fact, contribute impurities to the steam cycle. This paper reviews recent data compiled to determine the direct and indirect effects of amines on ion exchange resins used in the power industry. Water chemistries have improved in recent years, in large part due to changes in chemistry and resins, but it is necessary to continue to develop products, processes and techniques to reduce impurities and improve overall water chemistry in power plant systems. (orig.)

  9. Feasibility of vitrifying EPICOR II organic resins

    International Nuclear Information System (INIS)

    Buelt, J.L.

    1981-11-01

    Two laboratory-scale runs have recently been completed to test the feasibility of a single-step incineration/vitrification process for Three Mile Island EPICOR II resins. The process utilizes vitrification equipment, specifically a 15-cm-dia in-can melter, and a specially designed feed technique. Two process tests, each conducted with 1.2 kg of EPICOR II resins loaded with nonradioactive cesium and strontium, showed excellent operational characteristics. Less than 0.8 wt% of the resins were entrained with the gaseous effluents in the second test. Cesium and strontium losses were controlled to 0.71 wt% and less. In addition, all the carbonaceous resins were converted completely to CO 2 with no detectable CO. Future activities are being directed to longer-term tests in laboratory-scale equipment to determine attainable volume reduction, process rates, and material conformance to processing conditions

  10. Photopolymerizable silicone monomers, oligomers, and resins

    International Nuclear Information System (INIS)

    Jacobine, A.F.; Nakos, S.T.

    1992-01-01

    The purpose of this chapter is to acquaint the general photopolymer researcher with the historical development of the chemistry and technology of photopolymerizable silicone monomers, fluids, and resins. The current status of research in these areas is assessed. The focus of this chapter is not only on the polymer chemistry and application of this technology, but also on important aspects of the synthetic chemistry involved in the preparation of UV-curable silicone monomers, oligomers, and resins. 236 refs., 6 tabs

  11. Cycloaliphatic epoxide resins for cationic UV - cure

    International Nuclear Information System (INIS)

    Verschueren, K.; Balwant Kaur

    1999-01-01

    This paper introduces the cyclo - aliphatic epoxide resins used for the various applications of radiation curing and their comparison with acrylate chemistry. Radiation curable coatings and inks are pre - dominantly based on acrylate chemistry but over the last few years, cationic chemistry has emerged successfully with the unique properties inherent with cyclo - aliphatic epoxide ring structures. Wide variety of cationic resins and diluents, the formulation techniques to achieve the desired properties greatly contributes to the advancement of UV - curing technology

  12. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  13. Acid-base titrations by stepwise addition of equal volumes of titrant with special reference to automatic titrations-II Theory of titration of mixtures of acids, polyprotic acids, acids in mixture with weak bases, and ampholytes.

    Science.gov (United States)

    Pehrsson, L; Ingman, F; Johansson, S

    A general method for evaluating titration data for mixtures of acids and for acids in mixture with weak bases is presented. Procedures are given that do not require absolute [H]-data, i.e., relative [H]-data may be used. In most cases a very rough calibration of the electrode system is enough. Further, for simple systems, very approximate values of the stability constants are sufficient. As examples, the titration of the following are treated in some detail: a mixture of two acids, a diprotic acid, an acid in presence of its conjugate base, and an ampholyte.

  14. Cleanup of TMI-2 demineralizer resins

    International Nuclear Information System (INIS)

    Bond, W.D.; King, L.J.; Knauer, J.B.; Hofstetter, K.J.; Thompson, J.D.

    1985-01-01

    Radiocesium is being removed from Demineralizers A and B (DA and DB by a process that was developed from laboratory tests on small samples of resin from the demineralizers. The process was designed to elute the radiocesium from the demineralizer resins and then to resorb it onto the zeolite ion exchangers contained in the Submerged Demineralizer System (SDS). The process was also required to limit the maximum cesium activities in the resin eluates (SDS feeds) so that the radiation field surrounding the pipelines would not be excessive. The process consists of 17 stages of batch elution. In the initial stage, the resin is contacted with 0.18 M boric acid. Subsequent stages subject the resin to increasing concentrations of sodium in NaH 2 BO 3 -H 3 BO 3 solution (total B = 0.35 M) and then 1 M sodium hydroxide in the final stages. Results on the performance of the process in the cleanup of the demineralizers at TMI-2 are compared to those obtained from laboratory tests with small samples of the DA and DB resins. To date, 15 stages of batch elution have been completed on the demineralizers at TMI-2 which resulted in the removal of about 750 Ci of radiocesium from DA and about 3300 Ci from DB

  15. Benefit of slow titration of paroxetine to treat depression in the elderly.

    Science.gov (United States)

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Determination of polyhexamethylene biguanide hydrochloride using photometric colloidal titration with crystal violet as a color indicator.

    Science.gov (United States)

    Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki

    2011-01-01

    A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry

  17. 4He permeation and H2O uptake of cyanate ester resins — an alternative to commonly used epoxy resins at low temperature

    Science.gov (United States)

    Nakamura, Sachiko; Fujii, Takenori; Matsukawa, Shoji; Katagiri, Masayuki; Fukuyama, Hiroshi

    2018-03-01

    Cyanate ester (CE) thermoset is a polymer with a high glass-transition temperature of ≈ 300 °C. CE is expected to be an alternative to Stycast 1266 as a sealing and casting glue for low temperature experiments, especially for adsorption experiments where baking of the substrate at T > 100 °C before cooling is required to eliminate surface contaminations. We experimentally confirmed that thermosets of CE monomers are non-porous and absorbs/desorbs water very little from measurements of (1) 4He permeation properties at temperatures from room temperature (RT) to 77 K and of (2) weight gains (δW) after storage for days in water and in air at RT. The 4He permeation is rather large at RT but negligibly small at T ⪅ 130 K where the diffusion constant of 4He in CE is vanishingly small. δW in water and air are 0.3–0.5% and 0.5–1.0%, respectively, which are much smaller than those of Stycast 1266. Therefore, cyanate ester is an excellent alternative to commonly used epoxy resins especially in surface-sensitive experiments at low temperature.

  18. Implementation of a pharmacist-managed heart failure medication titration clinic.

    Science.gov (United States)

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  19. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    Science.gov (United States)

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Monitoring Acid–Base Titrations on Wax Printed Paper Microzones Using a Smartphone

    Directory of Open Access Journals (Sweden)

    Sandro A. Nogueira

    2017-05-01

    Full Text Available This study describes the use of a smartphone for monitoring acid–base titrations on wax printed paper microzones. An array of twelve microzones of 5 mm diameter each was wax printed on filter paper. The analytical performance of the proposed devices was explored with acid–base titrations examples, where jaboticaba peel extract was used as a natural pH indicator. The color intensity was captured using a smartphone and analyzed through a free App named Photometrix®. Before titrations, color intensity versus pH was calibrated to be used as a reference in titrations as (i strong acid versus strong base; (ii strong base versus strong acid; and (iii weak acid versus strong base. In all examples, images were obtained after the addition of each aliquot of titrant solutions. The obtained titration curves showed the same behavior as the conventional titration curves. After evaluating the feasibility of the proposed methodology, the concentration level of acetic acid was obtained in three vinegar samples. Although the obtained values ranged from 5% to 8% compared to the concentrations on the conventional method, the proposed methodology presented high analytical reliability. The calculated concentrations of acetic acid in three samples ranged from 3.87% to 3.93%, and the proposed methodology did not significantly differ from classic acid–base titration at a confidence level of 95%. The acid–base titration on paper-based devices is outstanding, since any titration can be completed within 5 min using 20 µL volumes. Besides, the use of a smartphone to capture images followed by analysis in a free app offers simplicity to all users. The proposed methodology arises as a new strand to be exploited in the diffusion of the analytical chemistry education field as well as an alternative for quantitative analysis with extremely simplified instrumentation.

  1. Simultaneous determination of equivalence volumes and acid dissociation constants from potentiometric titration data.

    Science.gov (United States)

    Papanastasiou, G; Ziogas, I

    1995-06-01

    New iterative methods for analysis of potentiometric titration data of (a) mixtures of weak monoprotic acids with their conjugate bases, (b) solutions of polyprotic (di- and triprotic) acids, and (c) mixtures of two diprotic acids are presented. These methods, using data exclusively resulting from the acidic region of the titration curve permits the accurate determination of the analytical concentration of one or more acids even if the titration is stopped well before the end point of the titration. For the titration of a solution containing a conjugate acid/base pair, the proposed procedure enables the extraction of the initial composition of the mixture, as well as the dissociation constant of the concerned acid. Thus, it is possible by this type of analysis to distinguish whether a weak acid has been contaminated by a strong base and define the extent of the contamination. On the other hand, for the titration of polyprotic acids, the proposed approach enables the extraction of the accurate values of the equivalence volume and the dissociation constants K(i) even when the ionization stages overlap. Finally, for the titration of a mixture of two diprotic acids the proposed procedure enables the determination of the composition of the mixture even if the sum of the concentrations of the acids is not known. This method can be used in the analysis of solutions containing two diastereoisomeric forms of a weak diprotic acid. The test of the proposed procedures by means of ideal and Monte Carlo simulated data revealed that these methods are fairly applicable even when the titration data are considerably obscured by 'noise' or contain an important systematic error. The proposed procedures were also successfully applied to experimental titration data.

  2. Titrating decision processes in the mental rotation task.

    Science.gov (United States)

    Provost, Alexander; Heathcote, Andrew

    2015-10-01

    Shepard and Metzler's (1971) seminal mental-rotation task-which requires participants to decide if 1 object is a rotated version of another or its mirror image-has played a central role in the study of spatial cognition. We provide the first quantitative model of behavior in this task that is comprehensive in the sense of simultaneously providing an account of both error rates and the full distribution of response times. We used Brown and Heathcote's (2008) model of choice processing to separate out the contributions of mental rotation and decision stages. This model-based titration process was applied to data from a paradigm where converging evidence supported performance being based on rotation rather than other strategies. Stimuli were similar to Shepard and Metzler's block figures except a long major axis made rotation angle well defined for mirror stimuli, enabling comprehensive modeling of both mirror and normal responses. Results supported a mental rotation stage based on Larsen's (2014) model, where rotation takes a variable amount of time with a mean and variance that increase linearly with rotation angle. Differences in response threshold differences were largely responsible for mirror responses being slowed, and for errors increasing with rotation angle for some participants. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  3. Predicting proton titration in cationic micelle and bilayer environments

    Science.gov (United States)

    Morrow, Brian H.; Eike, David M.; Murch, Bruce P.; Koenig, Peter H.; Shen, Jana K.

    2014-08-01

    Knowledge of the protonation behavior of pH-sensitive molecules in micelles and bilayers has significant implications in consumer product development and biomedical applications. However, the calculation of pKa's in such environments proves challenging using traditional structure-based calculations. Here we apply all-atom constant pH molecular dynamics with explicit ions and titratable water to calculate the pKa of a fatty acid molecule in a micelle of dodecyl trimethylammonium chloride and liquid as well as gel-phase bilayers of diethyl ester dimethylammonium chloride. Interestingly, the pKa of the fatty acid in the gel bilayer is 5.4, 0.4 units lower than that in the analogous liquid bilayer or micelle, despite the fact that the protonated carboxylic group is significantly more desolvated in the gel bilayer. This work illustrates the capability of all-atom constant pH molecular dynamics in capturing the delicate balance in the free energies of desolvation and Coulombic interactions. It also shows the importance of the explicit treatment of ions in sampling the protonation states. The ability to model dynamics of pH-responsive substrates in a bilayer environment is useful for improving fabric care products as well as our understanding of the side effects of anti-inflammatory drugs.

  4. Predicting proton titration in cationic micelle and bilayer environments

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, Brian H.; Shen, Jana K. [Department of Pharmaceutical Sciences, University of Maryland, Baltimore, Maryland 21201 (United States); Eike, David M.; Murch, Bruce P.; Koenig, Peter H. [Computational Chemistry, Modeling and Simulation GCO, Procter and Gamble, Cincinnati, Ohio 45201 (United States)

    2014-08-28

    Knowledge of the protonation behavior of pH-sensitive molecules in micelles and bilayers has significant implications in consumer product development and biomedical applications. However, the calculation of pK{sub a}’s in such environments proves challenging using traditional structure-based calculations. Here we apply all-atom constant pH molecular dynamics with explicit ions and titratable water to calculate the pK{sub a} of a fatty acid molecule in a micelle of dodecyl trimethylammonium chloride and liquid as well as gel-phase bilayers of diethyl ester dimethylammonium chloride. Interestingly, the pK{sub a} of the fatty acid in the gel bilayer is 5.4, 0.4 units lower than that in the analogous liquid bilayer or micelle, despite the fact that the protonated carboxylic group is significantly more desolvated in the gel bilayer. This work illustrates the capability of all-atom constant pH molecular dynamics in capturing the delicate balance in the free energies of desolvation and Coulombic interactions. It also shows the importance of the explicit treatment of ions in sampling the protonation states. The ability to model dynamics of pH-responsive substrates in a bilayer environment is useful for improving fabric care products as well as our understanding of the side effects of anti-inflammatory drugs.

  5. Modelling Dynamic Topologies via Extensions of VDM-RT

    DEFF Research Database (Denmark)

    Nielsen, Claus Ballegård

    Only a few formal methods include descriptions of the network topology that the modelled system is deployed onto. In VDM Real-Time (VDM-RT) this has been enabled for distributed systems that have a static structure. However, when modelling dynamic systems this fixed topology becomes an issue....... Systems with highly distributed and alternating relationships cannot be expressed correctly in a static model. This document describes how VDM-RT can be extended with new language constructs to enable the description of dynamic reconfiguration of the network topology during the runtime execution...... of a model. The extension is developed on the basis of a case study involving a dynamic system that has a constant changing system topology. With a basis in the case study a model is developed that uses the static version of VDM-RT in order to reveal the limitations of the language. The case study...

  6. Amperometric titration of thorium and some lanthanoids in acetic-acid medium using two indicator electrodes

    International Nuclear Information System (INIS)

    Khadeev, V.A.; Gevorgyan, A.M.; Talipov, Sh.T.; Kostylev, V.S.

    1979-01-01

    The votammetric behaviour of nitriletrimethylphosphonic acid (NTMP) in the medium of anhydrous acetic acid with different backgrounds in the anode region of polarization of a platinum microdisk electrode, is studied. The optimal conditions are found for the amperometric titration with two indicator electrodes of thorium and same lanthanides by a NTMP solution in anhydrous acetic medium. The influence of foreign anions and cations on the results of titration by the NTPM solution in anhydrous acetic acid is studied. The selectivity of titration in anhydrous medium is higher than in aqueous

  7. Free Software Development. 3. Numerical Description of Soft Acid with Soft Base Titration

    OpenAIRE

    Lorentz JÄNTSCHI; Horea Iustin NAŞCU

    2002-01-01

    The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. The present work is focus on modeling the process of titration and presents a numerical simulation of acid-base titration. A PHP program to compute all iterations in titration process that solves a 3th rank equation to find value of pH for was built and is available through http internet protocol at the address: http://vl.academicdirect.org/molecular_dynamics/ab_titra...

  8. Comparison of methods for accurate end-point detection of potentiometric titrations

    International Nuclear Information System (INIS)

    Villela, R L A; Borges, P P; Vyskočil, L

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper

  9. Determination of organic bases in non-aqueous solvents by catalytic thermometric titration.

    Science.gov (United States)

    Vajgand, V J; Kiss, T A; Gaál, F F; Zsigrai, I J

    1968-07-01

    Catalytic thermometric titrations have been developed for bases (brucine, diethylaniline, potassium acetate and triethylamine) in acetic acid by continuous and discontinuous addition of the standard solution and automatic temperature recording. The determination of weak bases, e.g., antipyrine, unsuccessful in acetic acid by catalytic thermometric titration, has been achieved by using nitromethane or acetic anhydride as solvent. Catalytic thermometric titrations were also performed by coulometric generation of hydrogen ions for the determination of micro amounts of weak bases in a mixture of acetic anhyride and acetic acid.

  10. Characterization of antibody-chelator conjugates: Determination of chelator content by terbium fluorescence titration

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, K.D.; Schnobrich, K.E.; Johnson, D.K. (Abbott Laboratories, Department 90M, Abbott Park, IL (United States))

    1991-01-01

    Fluorescence titrations were performed by adding varying mole ratios of terbium(III) to antibody conjugates formed by benzyl isothiocyanate derivatives of three different polyaminopolycarboxylate chelators (NTA, EDTA, and DTPA) and the results compared to values for average chelator content obtained by cobalt-57 binding assays. For two different murine monoclonal antibodies, the average chelator content obtained by terbium fluorescence titration correlated closely with that measured by the cobalt-57 binding assay. It is concluded that lanthanide fluorescence titrations provide a useful alternative to radiometal binding assays for the determination of chelator content in protein-chelator conjugates.

  11. Characterization of antibody-chelator conjugates: Determination of chelator content by terbium fluorescence titration

    International Nuclear Information System (INIS)

    Brandt, K.D.; Schnobrich, K.E.; Johnson, D.K.

    1991-01-01

    Fluorescence titrations were performed by adding varying mole ratios of terbium(III) to antibody conjugates formed by benzyl isothiocyanate derivatives of three different polyaminopolycarboxylate chelators (NTA, EDTA, and DTPA) and the results compared to values for average chelator content obtained by cobalt-57 binding assays. For two different murine monoclonal antibodies, the average chelator content obtained by terbium fluorescence titration correlated closely with that measured by the cobalt-57 binding assay. It is concluded that lanthanide fluorescence titrations provide a useful alternative to radiometal binding assays for the determination of chelator content in protein-chelator conjugates

  12. Linear regression analysis of potentiometric titration data for asymmetric redox reactions

    International Nuclear Information System (INIS)

    Mar'yanov, B.M.; Gavrilenko, M.A.

    1997-01-01

    A statistical method of processing the curves of potentiometric titration for homogeneous asymmetric redox reactions has been suggested. The method was tested using a model titrimetric system Mohr's salt-K 2 Cr 2 O 7 and was employed for Te determination in an individual solution, semiconductor alloy and CdTe ceramics. Random error of the equivalence point evaluation by the data of a specific titration of 0.1-0.01 M solutions does not exceed 0.3% in case of titration of 0.001 M solutions it increases up to 1.2%. The value of s r varies from 0.0006 to 0.007

  13. Comparison of methods for accurate end-point detection of potentiometric titrations

    Science.gov (United States)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  14. Soft-Rt: software for IMRT simulations based on MCNPX

    International Nuclear Information System (INIS)

    Ferreira F, T. C.; Campos, T.

    2015-10-01

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  15. AWIPS II Application Development, a SPoRT Perspective

    Science.gov (United States)

    Burks, Jason E.; Smith, Matthew; McGrath, Kevin M.

    2014-01-01

    The National Weather Service (NWS) is deploying its next-generation decision support system, called AWIPS II (Advanced Weather Interactive Processing System II). NASA's Short-term Prediction Research and Transition (SPoRT) Center has developed several software 'plug-ins' to extend the capabilities of AWIPS II. SPoRT aims to continue its mission of improving short-term forecasts by providing NASA and NOAA products on the decision support system used at NWS weather forecast offices (WFOs). These products are not included in the standard Satellite Broadcast Network feed provided to WFOs. SPoRT has had success in providing support to WFOs as they have transitioned to AWIPS II. Specific examples of transitioning SPoRT plug-ins to WFOs with newly deployed AWIPS II systems will be presented. Proving Ground activities (GOES-R and JPSS) will dominate SPoRT's future AWIPS II activities, including tool development as well as enhancements to existing products. In early 2012 SPoRT initiated the Experimental Product Development Team, a group of AWIPS II developers from several institutions supporting NWS forecasters with innovative products. The results of the team's spring and fall 2013 meeting will be presented. Since AWIPS II developers now include employees at WFOs, as well as many other institutions related to weather forecasting, the NWS has dealt with a multitude of software governance issues related to the difficulties of multiple remotely collaborating software developers. This presentation will provide additional examples of Research-to-Operations plugins, as well as an update on how governance issues are being handled in the AWIPS II developer community.

  16. Soft-Rt: software for IMRT simulations based on MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira F, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Campos, T., E-mail: tcff01@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Programa de Pos Graduacao em Ciencias e Tecnicas Nucleares, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Intensity Modulated Radiation Therapy (IMRT) is an advanced treatment technique, widely used in external radiotherapy. This paper presents the Soft-Rt which allows the simulation of an entire IMRT treatment protocol. The Soft-Rt performs a full three-dimensional rendering of a set of patient images, including the definitions of region of interest with organs in risk, and the target tumor volume and margins (PTV). Thus, a more accurate analysis and planning can be performed, taking into account the features and orientation of the radiation beams. The exposed tissues as well as the amount of absorbed dose is depicted in healthy and/or cancerous tissues. As conclusion, Soft-Rt can predict dose on the PTV accurately, preserving the surrounding healthy tissues. Soft-Rt is coupled with SISCODES code. The SISCODES code is firstly applied to segment the set of CT or MRI patient images in distinct tissues pointing out its respective density and chemical compositions. Later, the voxel model is export to the Soft-Rt IMRT planning module in which a full treatment planning is created. All geometrical parameters are sent to the general purpose Monte Carlo transport code - MCNP - to simulate the interaction of each incident beam towards to the PTV avoiding organs in risk. The normalized dose results are exported to the Soft-Rt out-module, in which the three-dimensional model visualization is shown in a transparent glass procedure adopting gray scale for the dependence on the mass density of the correlated tissue; while, a color scale to depict dose values in a superimpose protocol. (Author)

  17. RT-PCR Detection of HIV in Republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Golubinka Bosevska

    2008-11-01

    Full Text Available The aim of the study was to detect HIV RNA in seropositive patients using RT-PCR method and thus, to establish PCR methodology in the routine laboratory works.The total of 33 examined persons were divided in two groups: 1 13 persons seropositive for HIV; and 2 20 healthy persons - randomly selected blood donors that made the case control group. The subjects age was between 25 and 52 years (average 38,5.ELFA test for combined detection of HIV p24 antigen and anti HIV-1 + 2 IgG and ELISA test for detection of antibodies against HIV-1 and HIV-2, were performed for each examined person. RNA from the whole blood was extracted using a commercial kit based on salt precipitation. Detection of HIV RNA was performed using RT-PCR kit. Following nested PCR, the product was separated by electrophoresis in 1,5 % agarose gel. The result was scored positive if the band of 210bp was visible regardless of intensity Measures of precaution were taken during all the steps of the work and HIV infected materials were disposed of accordingly.In the group of blood donors ELFA, ELISA and RT-PCR were negative. Assuming that prevalence of HIV infection is zero, the clinical specificity of RT-PCR is 100 %. The analytical specificity of RT-PCR method was tested against Hepatitis C and B, Human Papiloma Virus, Cytomegalovirus, Herpes Simplex Virus, Rubella Virus, Mycobacterium tuberculosis, Chlamydia trachomatis. None of these templates yielded amplicon. In the group of 13 seropositive persons, 33 samples were analyzed. HIV RNA was detected in 15 samples. ELISA and ELFA test were positive in all samples. Different aliquots of the samples were tested independently and showed the same results. After different periods of storing the RNA samples at -70°C, RT-PCR reaction was identical to the one performed initially. The obtained amplicons were maintained frozen at -20°C for a week and the subsequently performed electrophoresis was identical to the previous one. The reaction is

  18. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    Directory of Open Access Journals (Sweden)

    Adilson Yoshio Furuse

    2007-12-01

    Full Text Available The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1 rinsing with water and drying; (G2 application of an adhesive system; (G3 rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4 rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (p<0.05. Similar values to the original bond strength were obtained after abrasion and application of adhesive (G3 or etching and application of silane and adhesive (G4. If contamination occurs, a surface treatment is required to guarantee an adequate interaction between the resin increments.

  19. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel

    2007-01-01

    of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin...

  20. Accurate and precise determination of 2-25mg amounts of uranium by means of a special automatic potentiometric titration

    International Nuclear Information System (INIS)

    Slanina, J.; Bakker, F.; Groen, A.J.P.; Lingerak, W.A.

    1978-01-01

    A precise and accurate potentiometric titration of 2-25 mg of uranium is described. The uranium is reduced to U(IV) according to the method of Eberle et al. [3], and titrated with 0.05 N potassium dichromate, using a platinum indicator electrode. During the sample preparation the walls of the titration vessel are cleaned by centrifugation. To avoid overshoot of the set point a special differentiator is described, that interrupts the titration until equilibrium is reached. The precision of the method is 0.02%, the accuracy is better than 0.04% rel. Each titration takes 5 min. (orig.) [de

  1. Implementation of 'Davies and Gray/NBL Method' for potentiometric titration of uranium in the Safeguards Laboratory of CNEN by the use of a DL-67 mettler titrator

    International Nuclear Information System (INIS)

    Araujo, Radier Mario Silveira de; Barros, Pedro Dionisio de

    2005-01-01

    To meet the requirements of the Brazilian State System of Accounting for and Control of Nuclear Materials - SSAC, the Safeguards Laboratory of CNEN - LASAL has been applying the 'Davies and Gray/NBL' method for potentiometric determination of total uranium concentration in uranium samples taken during safeguards inspections at nuclear facilities since 1984, using a Radiometer ETS 822 titrator. In order to improve the analytical capability and the procedures related to the titration methodology, the same method was also implemented by using a METTLER DL - 67 titrator. This equipment is microprocessor - controlled and can be connected to additional devices such as printers, analytical balances, etc. It also provides accurate and reproducible results for end-point titrations, providing analytical performance according to the current international safeguards requirements. The implementation of the method in such equipment included the addition of analytical data as well as the improvement of the equipment parameters for uranium determination. Parameters like predispensing volume; titrant data and end-point value were studied. Some uranium samples (solids and solutions) were used during the initial tests with the titrator. A solution of pure uranyl nitrate was used as reference sample for this paper. From this, aliquots were analyzed in both Radiometer ETS-822 and METTLER DL-67. Results obtained from each equipment were compared with the reference value of the sample. The comparison showed that results from METTLER DL-67 meets the precision and accuracy requirements for this kind of analysis and led to the conclusion that the performance of this titrator is adequate for the determination of total uranium content in samples of nuclear materials for safeguards purposes. (author)

  2. Thermal cycling effects on adhesion of resin-bovine enamel junction among different composite resins.

    Science.gov (United States)

    Chen, Wen-Cheng; Ko, Chia-Ling; Wu, Hui-Yu; Lai, Pei-Ling; Shih, Chi-Jen

    2014-10-01

    Thermal cycling is used to mimic the changes in oral cavity temperature experienced by composite resins when used clinically. The purpose of this study is to assess the thermal cycling effects of in-house produced composite resin on bonding strength. The dicalcium phosphate anhydrous filler surfaces are modified using nanocrystals and silanization (w/NP/Si). The resin is compared with commercially available composite resins Filtek Z250, Z350, and glass ionomer restorative material GIC Fuji-II LC (control). Different composite resins were filled into the dental enamel of bovine teeth. The bond force and resin-enamel junction graphical structures of the samples were determined after thermal cycling between 5 and 55°C in deionized water for 600 cycles. After thermal cycling, the w/NP/Si 30wt%, 50wt% and Filtek Z250, Z350 groups showed higher shear forces than glass ionomer GIC, and w/NP/Si 50wt% had the highest shear force. Through SEM observations, more of the fillings with w/NP/Si 30wt% and w/NP/Si 50wt% groups flowed into the enamel tubule, forming closed tubules with the composite resins. The push-out force is proportional to the resin flow depth and uniformity. The push-out tubule pore and resin shear pattern is the most uniform and consistent in the w/NP/Si 50wt% group. Accordingly, this developed composite resin maintains great mechanical properties after thermal cycling. Thus, it has the potential to be used in a clinical setting when restoring non-carious cervical lesions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    Science.gov (United States)

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  4. A Computer-Based Simulation of an Acid-Base Titration

    Science.gov (United States)

    Boblick, John M.

    1971-01-01

    Reviews the advantages of computer simulated environments for experiments, referring in particular to acid-base titrations. Includes pre-lab instructions and a sample computer printout of a student's use of an acid-base simulation. Ten references. (PR)

  5. Titration of Alanine Monitored by NMR Spectroscopy: A Biochemistry Laboratory Experiment

    Science.gov (United States)

    Waller, Francis J.; And Others

    1977-01-01

    The experiment described here involves simultaneous monitoring of pH and NMR chemical shifts during an aqueous titration of alpha- and beta-alanine. This experiment is designed for use in an undergraduate biochemistry course. (MR)

  6. Hot dewatering and resin encapsulation of intermediate level radioactive waste

    International Nuclear Information System (INIS)

    Rickman, J.; Birch, D.

    1985-01-01

    The chemistry of the processes involved in the hot dewatering and encapsulation of alumino-ferric hydroxide floc in epoxide resin have been studied. Pretreatment of the floc to reduce resin attack and hydrolysis and to increase the dimensional stability of the solidified wasteform has been evaluated. It has been demonstrated that removal of ammonium nitrate from the floc and control of the residual water in the resin are important factors in ensuring dimensional stability of the solidified resin. Resin systems have been identified which, together with the appropriate waste pretreatment have successfully encapsulated a simulated magnox sludge producing a stable wasteform having mechanical and physical properties comparable with the basic resin. (author)

  7. Kirjanduskriitikute suvemängud / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    2007-01-01

    Arvustus: Lodge, David. Ühest kohast teise / tlk. Aet Varik. Tallinn : Varrak, 2005 ; Lodge, David. Väike maailm / tlk. Kersti Unt. Tallinn : Varrak, 1996 ; Lodge, David. Väärt töö / tlk. Kersti Unt. Tallinn : Varrak, 2006

  8. Future of the reprocessing business at the RT-1 plant

    International Nuclear Information System (INIS)

    Bukharin, O.

    1995-01-01

    Economic viability of reprocessing operations at the RT-1 plant is provided by the contracts with nuclear utilities from Finland and Hungary. Finland will stop sending fuel to Mayak for reprocessing after 1996. Hungary will be capable to resolve the problem of spent fuel domestically some time in the future. This increases vulnerability of the reprocessing business at Mayak to future political uncertainties. (author)

  9. RT-PCR Protocols - Methods in Molecular Biology

    Directory of Open Access Journals (Sweden)

    Manuela Monti

    2011-03-01

    Full Text Available “The first record I have of it, is when I made a computer file which I usually did whenever I had an idea, that would have been on the Monday when I got back, and I called it Chain Reaction.POL, meaning polymerase. That was the identifier for it and later I called the thing the Polymerase Chain Reaction, which a lot of people thought was a dumb name for it, but it stuck, and it became PCR”. With these words the Nobel prize winner, Kary Mullis, explains how he named the PCR: one of the most important techniques ever invented and currently used in molecular biology. This book “RT-PCR Protocols” covers a wide range of aspects important for the setting of a PCR experiment for both beginners and advanced users. In my opinion the book is very well structured in three different sections. The first one describes the different technologies now available, like competitive RT-PCR, nested RT-PCR or RT-PCR for cloning. An important part regards the usage of PCR in single cell mouse embryos, stressing how important...........

  10. rt, Arvo: De profundis. Missa Sillabica / Patric Wiklacz

    Index Scriptorium Estoniae

    Wiklacz, Patric

    1997-01-01

    Uuest heliplaadist "Pärt, Arvo: De profundis. Missa Sillabica. Solfeggio. And one of the Pharisees. Cantate Domino. Summa. 7 Antiennes du Magnificat. The Beautitudes. Magnificat. Christopher Bowers-Broadbent (org.), Daniel Kennedy (perc.). Theatre of Voices / Paul Hillier (bass)" Harmonia Mundi HMU907 182 F (CD:165F). 1996. TT:1h 16'06"

  11. Narr kui ajastu metafoor / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    2001-01-01

    William Shakespeare'i "Kuningas Lear" (lav. Priit Pedajas) ja Pedro Calder̤n de la Barca "Elu on unenägu" (lav. Ingo Normet) Eesti Draamateatris. Ilmunud ka kogumikus : Hellerma, Kärt. Avanenud ruum. Tallinn : Eesti Keele Sihtasutus, 2006, lk. 213-216. Pealk. Narr kui meie aja kangelane

  12. rt: Chamber and Orchestral Works / Robert Cowan

    Index Scriptorium Estoniae

    Cowan, Robert

    1994-01-01

    Uuest heliplaadist "Pärt: Chamber and Orchestral Works. Bournemouth Sinfonietta, Richard Studt. EMI Eminence CD CD-EMX 2221; Fratres; Cantus in memory of Benjamin Britten; Summa; Spiegel im Spiegel; Festina lente; Tabula Rasa; Fratres - selected comparison: Bachmann, Kibonoff (12/94)(CATA) 09026 61824-2. Kremer, Jarrett (ECM) 817 764-2

  13. 25 kaadrit sekundis / Liis Auväärt

    Index Scriptorium Estoniae

    Auväärt, Liis

    2009-01-01

    Nukufilmis käib töö filmiga "Lisa Limone & Maroc Orange", režissöör Mait Laas, animaatorid Triin Sarapik-Kivi, Märt Kivi, operaator Ragnar Neljandi, nukumeistrid Heigo Eeriksoo, Taivo Müürsep, Ene Mellow ja Kreeta Käeri. Dekoratsioonimeistrid Mait Erik ja Roman Kuznetsov

  14. rt, Arvo: De profundis / Barry Witherden

    Index Scriptorium Estoniae

    Witherden, Barry

    1997-01-01

    Uuest heliplaadist "Pärt, Arvo: De profundis. Missa Sillabica. Solfeggio. And one of the Pharisees. Cantate Domino. Summa. Seven Magnificat Antiphons. The Beautitudes. Magnificat. Christopher Bowers-Broadbent (org.), Daniel Kennedy (perc.). Theatre of Voices / Paul Hillier (bass)". Harmonia Mundi HMU40 7182; HMU90 7182 (76 minutes:DDD)

  15. Torm Balti merel / Märt Treier ; interv. Inge Pitsner

    Index Scriptorium Estoniae

    Treier, Märt, 1975-

    2004-01-01

    TV3 näitab saksa poliitilist põnevusfilmi "Balti torm" ("Baltic Storm"), mis kujutab parvlaev "Estonia" hukku : stsenarist, produtsent Jutta Rabe : režissöör Reuben Leder. Filmi eel on teles Märt Treieri saade "Tormist sündinud tormid"

  16. Karje kunstniku südamest / Kärt Hellerma

    Index Scriptorium Estoniae

    Hellerma, Kärt, 1956-

    1997-01-01

    Arvustus: Dinesen, Isak [Blixen, Karen]. Babette'i pidusöök / tlk. Piret Peiker. Tallinn : Varrak, 1996. Ilmunud ka kogumikus: Hellerma, Kärt. Kohanenud kirjandus : valik kirjanduskriitikat 1987-2006. Eesti Keele Sihtasutus : Tallinn, 2006. Lk. 167-169

  17. Isothermal titration calorimetry in nanoliter droplets with subsecond time constants.

    Science.gov (United States)

    Lubbers, Brad; Baudenbacher, Franz

    2011-10-15

    We reduced the reaction volume in microfabricated suspended-membrane titration calorimeters to nanoliter droplets and improved the sensitivities to below a nanowatt with time constants of around 100 ms. The device performance was characterized using exothermic acid-base neutralizations and a detailed numerical model. The finite element based numerical model allowed us to determine the sensitivities within 1% and the temporal dynamics of the temperature rise in neutralization reactions as a function of droplet size. The model was used to determine the optimum calorimeter design (membrane size and thickness, junction area, and thermopile thickness) and sensitivities for sample volumes of 1 nL for silicon nitride and polymer membranes. We obtained a maximum sensitivity of 153 pW/(Hz)(1/2) for a 1 μm SiN membrane and 79 pW/(Hz)(1/2) for a 1 μm polymer membrane. The time constant of the calorimeter system was determined experimentally using a pulsed laser to increase the temperature of nanoliter sample volumes. For a 2.5 nanoliter sample volume, we experimentally determined a noise equivalent power of 500 pW/(Hz)(1/2) and a 1/e time constant of 110 ms for a modified commercially available infrared sensor with a thin-film thermopile. Furthermore, we demonstrated detection of 1.4 nJ reaction energies from injection of 25 pL of 1 mM HCl into a 2.5 nL droplet of 1 mM NaOH. © 2011 American Chemical Society

  18. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    Science.gov (United States)

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements

  19. Comparison of VFA titration procedures used for monitoring the biogas process.

    Science.gov (United States)

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of

  20. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    Science.gov (United States)

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Determination of opium and strychnos alkaloids by radiometric titrations with potassium thallium(I) iodide reagent

    International Nuclear Information System (INIS)

    Rama Rao, V.V.; Singh, N.J.; Tandon, S.N.

    1980-01-01

    The titrations were carried out by the batch method in test tubes, using 204 Tl-labelled potassium thallium(I) iodide as precipitant for alkaloids such as codeine, morphine, narcotine, papaverine, thebaine, strychnine and brucine. Direct and reverse titrations were investigated including sensitivity and accuracy. Codeine and narcotine were determined in some pharmaceutical preparations such as codeine sulfate tablets, codopyrin tablets and coscopin syrup

  2. Microchemical analysis of materials based on Y-Ba-Cu by spectrophotometric titration

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.; Zakharov, Eh.K.

    1990-01-01

    A complex method for analysis of superconductor and similar materials on Y-Ba-Cu basis has been developed, which comprises yttrium and copper determination by their indicator spectrophotometric titration by EDTA and/or complexone 4 in the presence of arsenazo 3. The use of complexone 4 is more favourable. Titration is carried out at λ=650 nm. The method has a sufficient accuracy, provides for rapid determination and does not reguire preliminary separation of components

  3. Opuntia ficus indica (L.) Fruit Extract as Natural Indicator in Acid-Base Titration

    OpenAIRE

    Manoj A. Suva

    2014-01-01

    In routine experiments synthetic indicators are the choice of acid base titrations. But there are some limitations like environmental pollution, availability and higher cost which leads to search for natural compounds as an acid base indicator was started. The present work highlights theexploit of the methanolic and aqueous extract of the fruit of Opuntia ficus indica plants as a natural acid base indicator in acid base titrations. Opuntia ficus indica plant was identified and fruits were was...

  4. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    Science.gov (United States)

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  5. Potentiometric titration of zinc and cadmium in electrolytes of in galvanic baths

    International Nuclear Information System (INIS)

    Kosyuga, E.A.; Kalugin, A.A.; Gur'ev, I.A.

    1979-01-01

    The method of potentiometric titration of zinc and cadmium by complexone 3 in electrolytes of galvanic baths using sulphide - silver electrode for determining the finite point of titration is suggested. Copper (2) ions are proposed as indicator ions. The potentiometric determination should be performed at pH=10. The method is verified on model electrolyte solutions and on the electrolyte solutions of operating baths.The technique can be used for automatic control. The time for analysis is 10 minutes

  6. Determination of the aggregation number for micelles by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Olesen, Niels Erik; Holm, Rene; Westh, Peter

    2014-01-01

    Isothermal titration calorimetry (ITC) has previously been applied to estimate the aggregation number (n), Gibbs free energy (ΔG), enthalpy (ΔH) and entropy (ΔS) of micellization. However, some difficulties of micelle characterization by ITC still remain; most micelles have aggregation numbers...... insight into optimal design of titration protocols for micelle characterization. By applying the new method, the aggregation number of sodium dodecyl sulphate and glycochenodeoxycholate was determined at concentrations around their critical micelle concentration (CMC)...

  7. Molecular Weight Measurement of Biobased Furan Polyamides via Non-Aqueous Potentiometric Titration

    Science.gov (United States)

    2013-06-01

    electromagnetic fields, all titrations were completed in a chemical hood, which acted as a Faraday cage (a shield used to blocks external static and...while using DMF as a solvent. Additionally, no Faraday cage was used in the experimental setup, so the titrations were conducted inside the chemical...monomer was becoming more soluble in glacial acetic acid and the amount of chlorobenzene had less of an effect on the solution properties (i.e

  8. Characterization of Polyimide Matrix Resins and Prepregs

    Science.gov (United States)

    Maximovich, M. G.; Galeos, R. M.

    1985-01-01

    Graphite/polyimide composite materials are attractive candidates for a wide range of aerospace applications. They have many of the virtues of graphite/epoxies, i.e., high specific strengths and stiffness, and also outstanding thermal/oxidative stability. Yet they are not widely used in the aerospace industry due to problems of procesability. By their nature, modern addition polyimide (PI) resins and prepregs are more complex than epoxies; the key to processing lies in characterizing and understanding the materials. Chemical and rheological characterizations are carried out on several addition polyimide resins and graphite reinforced prepregs, including those based on PMR-15, LARC 160 (AP 22), LARC 160 (Curithane 103) and V378A. The use of a high range torque transducer with a Rheometrics mechanical spectrometer allows rheological data to be generated on prepreg materials as well as neat resins. The use of prepreg samples instead of neat resins eliminates the need for preimidization of the samples and the data correlates well with processing behavior found in the shop. Rheological characterization of the resins and prepregs finds significant differences not readily detected by conventional chemical characterization techniques.

  9. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    International Nuclear Information System (INIS)

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  10. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    Energy Technology Data Exchange (ETDEWEB)

    Asakai, Toshiaki, E-mail: t-asakai@aist.go.jp [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan); Hioki, Akiharu [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba Central 3-9, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563 (Japan)

    2011-03-09

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  11. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jones, Daniel H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  12. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    Science.gov (United States)

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (ptitration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    International Nuclear Information System (INIS)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    2017-01-01

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration was determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.

  14. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  15. Determination of free acid in U(VI)-Al(III) solution by Gran plot titration

    International Nuclear Information System (INIS)

    Suh, Moo Yul; Lee, Chang Heon; Sohn, Se Chul; Kim, Jung Suk; Kim, Won Ho; Eom, Tae Yoon

    1999-01-01

    The determination method of free acid in spent U-Al nuclear fuel solutions by Gran plot titration was described. Effect of U(VI) and Al(III) on the alkalimetric titration of nitric acid was investigation in oxalate complexing media as well as in noncomplexing media. Positive biases were observed in both titration media when the end-point was estimated by the Gran plot method. It was found that the cause of the bias was U(VI) in the oxalate complexing media, but Al(III) in the noncomplexing media. The relative error was less than 1% in the titration of 0.1 M HNO 3 at a U(VI):Al(III):H + mole ratio of up to 2:12:1 as long as the pH of the oxalate titration media was sustained to be below 5.0 at the beginning of titration. The method was successfully applied to the determination of nitric acid in a solution of HANARO reactor fuel with U:Al mole ratio of 1:6

  16. Investigation of iodine liberation process in redox titration of potassium iodate with sodium thiosulfate

    International Nuclear Information System (INIS)

    Asakai, Toshiaki; Hioki, Akiharu

    2011-01-01

    Potassium iodate is often used as a reference material to standardize a sodium thiosulfate solution which is a familiar titrant for redox titrations. In the standardization, iodine (triiodide) liberated by potassium iodate in an acidic potassium iodide solution is titrated with a sodium thiosulfate solution. The iodine liberation process is significantly affected by the amount of acid, that of potassium iodide added, the waiting time for the liberation, and light; therefore, the process plays a key role for the accuracy of the titration results. Constant-voltage biamperometry with a modified dual platinum-chip electrode was utilized to monitor the amount of liberated iodine under several liberation conditions. Coulometric titration was utilized to determine the concentration of a sodium thiosulfate solution on an absolute basis. Potassium iodate was assayed by gravimetric titration with the sodium thiosulfate solution under several iodine liberation conditions. The liberation process was discussed from the changes in the apparent assay of potassium iodate. The information of the appropriate titration procedure obtained in the present study is useful for any analysts utilizing potassium iodate to standardize a thiosulfate solution.

  17. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    Science.gov (United States)

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  18. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    Directory of Open Access Journals (Sweden)

    Grace Wu

    Full Text Available Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration.To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia.Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration.Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3, respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute.Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  19. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    Science.gov (United States)

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  20. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level

    International Nuclear Information System (INIS)

    Sahoo, P.; Ananthanarayanan, R.; Malathi, N.; Rajiniganth, M.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 μg L -1 levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L -1 levels, with modification in methodology for accurate detection of end point even at 10.0 μg L -1 levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 μg L -1 O 2 . Finally, several water samples containing dissolved oxygen from mg L -1 to μg L -1 levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 μg L -1 O 2 level is 0.14 (n = 5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 μg L -1 levels.

  1. Ion chromatography for the analysis of salt splitting capacities of cation and anion resin in premixed resin sample

    International Nuclear Information System (INIS)

    Ghosh, Satinath; Kumar, Rakesh; Tripathy, M.K.; Dhole, K.; Sharma, R.S.; Varde, P.V.

    2017-01-01

    Mixed bed ion exchange resin is commonly used in various plants including nuclear reactors for the purpose of fine polishing. The analysis of ion exchange capacities of cation and anion resin in resin mixture is therefore an agenda in the context of purchasing of premixed resin from the manufacturer. An ion chromatographic method for assaying ion exchange capacities of pure as well as mixed resin has been optimized. The proposed method in contrast to the conventional ASTM method has been found to be quite encouraging to consider it as an alternate method for the analysis of premixed resin. (author)

  2. Ponderosa pine resin defenses and growth: metrics matter.

    Science.gov (United States)

    Hood, Sharon; Sala, Anna

    2015-11-01

    Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow

  3. Arvo Pärt jagab preemia koolidele / Rebekka Lotman, Eva Kübar ; kommenteerinud Arvo Pärt

    Index Scriptorium Estoniae

    Lotman, Rebekka, 1978-

    2009-01-01

    Kultuuriministeerium tegi ettepaneku anda Arvo Pärdile elutööpreemia, millega kaasneva rahasumma lubas Pärt kinkida Rakvere ja Paide muusikakoolile. Elutööpreemiad saavad veel Ellen Niit ja Aarne Üksküla

  4. rt Haamer: Tsahknal pole Overalliga mingisugust seost / Märt Haamer ; intervjueerinud Jan Jõgis-Laats

    Index Scriptorium Estoniae

    Haamer, Märt, 1973-

    2009-01-01

    Overall Eesti juhi Märt Haameri väitel pole Anders Tsahkna ühtegi riigihanget Overalli ettevõtetele suunanud. Overalli omandusse kuuluv firma Gennet Lab on olnud alltöövõtja paaris E-tervise Sihtasutuse korraldatud hankes

  5. Immobilisation of ion exchange resins in cement

    International Nuclear Information System (INIS)

    Howard, C.G.; Jolliffe, C.B.; Lee, D.J.

    1990-02-01

    Over the last seven years, Low Oxidation State Metal Ion reagents (LOMI) have been used to decontaminate the 100 MW(e) Steam Generating Heavy Water Ractor (SGHWR) at Winfrith. The use of these reagents has resulted in a dilute ionic solution containing activation products which are produced by corrosion of metallic components in the reactor. It has been demonstrated that the amount of activity in the solution can be reduced using organic ion exchanger resins. These resins consist of a cross linked polystyrene with sulphonic acid or quaternary ammonium function groups and can be successfully immobilised in blended cement systems. The formulation which has been developed is produced from a 9 to 1 blend of ground granulated blast furnace slag (BFS) and ordinary Portland cement (OPC) containing 28% ion exchange resin in the water saturated form. If 6% Microsilica is added to the blended cement the waste loading can be increased to 36 w/o. (author)

  6. Thermosetting resins for nuclear track detection

    International Nuclear Information System (INIS)

    Fujii, M.; Yokota, R.

    1986-01-01

    Several new thermosetting resins with a three dimensional network structure similar to that of CR-39 were polymerized to study their characteristics as nuclear track detectors. The comparison of the molecular structures of these resins gives us an important clue to develop highly sensitive polymeric track detectors. For example, butanediol bis allylcarbonate (BuAC) shows the sensitivity about ten times higher than diallyl and adipate (DAA). This suggests the carbonate groups in the BuAC molecule provide a much higher sensitivity than the ester groups in the DAA. During the course of this study, thermosetting resins with good etching properties and various sensitivities have been developed. Though the sensitivity of DAA is low, it will be useful for observations of ultra heavy cosmic rays and heavily ionizing particles at low energies. (author)

  7. Aging in CTBN modified epoxy resin stocks

    International Nuclear Information System (INIS)

    Creed, K.E. Jr.

    1979-01-01

    The cause of degradation in the glass transition temperature (T/sub G/) of a partially crystallized polymer was investigated. Sample epoxy resin filled capacitors were cured at 90 0 C for 24 hours, then stored at room atmospheric conditions. These showed typical degradation in T/sub G/ after storage for one month. One set of epoxy resin castings was stored at room atmosphere and another set was stored in a dry box at 0% relative humidity and 27 0 C. The samples at room atmospheric conditions showed typical degradation in T/sub G/, while the T/sub G/ for those stored in the dry box increased. Further tests were then made on epoxy resin castings at various curing temperatures and times at both room atmosphere and 0% humidity. Resulting data indicated that absorption of moisture during storage was the predominant cause of T/sub G/ degradation, with stress relaxation another, though smaller, contributing factor

  8. Restoration of traumatized teeth with resin composites

    DEFF Research Database (Denmark)

    Pallesen, Ulla; van Dijken, Jan WV

    2018-01-01

    For a long time, the primary choice for initial restoration of a crown-fractured front tooth has been resin composite material. The restoration can in most cases be performed immediately after injury if there is no sign of periodontal injury. The method’s adhesive character is conservative to tooth...... present an aesthetic problem due to exposure of un-aesthetic crown-margins. The invasive permanent crown restorations are therefore often not suc-cessful on a long-term scale. On the other hand, a conservative direct restoration of an extensively fractured incisor crown with resin composite may......-structure and with minimal risk of pulpal complication. In addition, it offers an aesthetic solution to the patient immediately after an injury, which may bring a little comfort in a sad situation. The resin composite build-up is often changed or repaired a couple of times, before the tooth is restored with a porcelain...

  9. Incineration of spent ion exchange resin

    International Nuclear Information System (INIS)

    Hasegawa, Chiaki

    1990-01-01

    It is a pressing need to reduce radioactive waste which is generated from the maintenance and operation of a nuclear power plant. Incineration of low level combustible solid waste such as polyethylene seats, paper and others have been successfully performed since 1984 at the Shimane Nuclear Power Station. Furthermore, for extending incineration treatment to spent ion exchange resin, the incineration test was carried out in 1989. However, as the cation exchange resin contains sulfur and then incineration generates SOx gases, so the components of this facility will be in a corrosive environment. We surveyed incineration conditions to improve the corrosive environment at the exhaust gas treatment system. This paper includes these test results and improved method to incinerate spent ion exchange resin. (author)

  10. Comparative study of resin sealant and resin modified glass ionomer as pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Shirin Malek

    2017-02-01

    Full Text Available The purpose of the present study was to compare the marginal integrity of resin modified glass ionomer cement with that of resin sealant, in vitro. Forty artificial pit and fissure cavities were prepared in occlusal surface of extracted premolar teeth by using ¼ round carbide bur. Cavities were condensed with artificial organic debris followed by cleaning with prophylaxis pumice brush and paste and then separated into two treatment groups. In Group A, 15 fissure cavities were sealed by resin sealant and in Group B, 15 fissure cavities were sealed by resin modified glass ionomer sealant. These specimens were subjected to thermo-cycling followed by dye penetration test. The remaining 5 cavities from each group were analyzed for debris score by the SEM. The results of the microleakage test showed that the efficacy of preventing microleakage of samples sealed by resin modified glass ionomer sealant was higher than the samples sealed by resin sealant. However, no significant differences were found. It can be concluded that use of resin modified glass ionomer sealant is a good alternative for sealing pits and fissures.

  11. Microshear bond strength of composite resins to enamel and porcelain substrates utilizing unfilled versus filled resins.

    Science.gov (United States)

    Najafi-Abrandabadi, Ahmad; Najafi-Abrandabadi, Siamak; Ghasemi, Amir; Kotick, Philip G

    2014-11-01

    Failures such as marginal discoloration and composite chipping are still the problems of tooth-colored restorations on the substrate of enamel and porcelain, which some of these problems are consequently as a result of failures in the bonding layer. Using filled resin has been recently introduced to increase the bond strength of this layer. The aim of this study was to compare the microshear bond strength (μ-SBS) of composite resins to enamel incubated in periods of 24 h and 9 months and porcelain with unfilled resin and flowable composites (filled resin). In this in vitro study, two groups of 75 enamel samples with different storage times (24 h and 9 months) and a group of 75 porcelain samples were used. They were divided into 5 experimental groups of 15 samples in each. Composite cylinders in tygon tubes were bonded on the surface of acid-etched enamel and pretreated porcelain. Wave, Wave MV, Wave HV, Grandioflow and Margin Bond were used as bonding agents. The μ-SBS was measured at the speed of 1.0 mm/min. The bond strengths were analyzed with one-way analysis of variance (ANOVA) test followed by Tukey test. P composites (filled resins) can be used instead of unfilled resins in bonding composite resins to enamel and porcelain substrates.

  12. Biphenyl liquid crystalline epoxy resin as a low-shrinkage resin-based dental restorative nanocomposite.

    Science.gov (United States)

    Hsu, Sheng-Hao; Chen, Rung-Shu; Chang, Yuan-Ling; Chen, Min-Huey; Cheng, Kuo-Chung; Su, Wei-Fang

    2012-11-01

    Low-shrinkage resin-based photocurable liquid crystalline epoxy nanocomposite has been investigated with regard to its application as a dental restoration material. The nanocomposite consists of an organic matrix and an inorganic reinforcing filler. The organic matrix is made of liquid crystalline biphenyl epoxy resin (BP), an epoxy resin consisting of cyclohexylmethyl-3,4-epoxycyclohexanecarboxylate (ECH), the photoinitiator 4-octylphenyl phenyliodonium hexafluoroantimonate and the photosensitizer champhorquinone. The inorganic filler is silica nanoparticles (∼70-100 nm). The nanoparticles were modified by an epoxy silane of γ-glycidoxypropyltrimethoxysilane to be compatible with the organic matrix and to chemically bond with the organic matrix after photo curing. By incorporating the BP liquid crystalline (LC) epoxy resin into conventional ECH epoxy resin, the nanocomposite has improved hardness, flexural modulus, water absorption and coefficient of thermal expansion. Although the incorporation of silica filler may dilute the reinforcing effect of crystalline BP, a high silica filler content (∼42 vol.%) was found to increase the physical and chemical properties of the nanocomposite due to the formation of unique microstructures. The microstructure of nanoparticle embedded layers was observed in the nanocomposite using scanning and transmission electron microscopy. This unique microstructure indicates that the crystalline BP and nanoparticles support each other and result in outstanding mechanical properties. The crystalline BP in the LC epoxy resin-based nanocomposite was partially melted during exothermic photopolymerization, and the resin expanded via an order-to-disorder transition. Thus, the post-gelation shrinkage of the LC epoxy resin-based nanocomposite is greatly reduced, ∼50.6% less than in commercialized methacrylate resin-based composites. This LC epoxy nanocomposite demonstrates good physical and chemical properties and good biocompatibility

  13. 76 FR 8774 - Granular Polytetrafluoroethylene Resin From Japan

    Science.gov (United States)

    2011-02-15

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-386 (Third Review)] Granular Polytetrafluoroethylene Resin From Japan AGENCY: United States International Trade Commission. ACTION: Termination of five... revocation of the antidumping duty order on granular polytetrafluoroethylene resin from Japan would be likely...

  14. Development of amino resin for paint formulation: Copolymerization ...

    African Journals Online (AJOL)

    SERVER

    2007-06-18

    Jun 18, 2007 ... IR spectroscopy and macro phase separation techniques. At a given TEA ... form aldehyde emission from urea formaldehyde resin through one step ..... of resin molecules (Barminas and Osemeahon, 2007;. Sekaran et al.

  15. Composite resin fillings and inlays: An 11-year evaluation

    DEFF Research Database (Denmark)

    Pallesen, U.; Qvist, V.

    2003-01-01

    Clinical trial, composite resin, direct restorations, indirect restorations, long-term behaviour, posterior teeth......Clinical trial, composite resin, direct restorations, indirect restorations, long-term behaviour, posterior teeth...

  16. Rapid viscosity measurements of powdered thermosetting resins

    Science.gov (United States)

    Price, H. L.; Burks, H. D.; Dalal, S. K.

    1978-01-01

    A rapid and inexpensive method of obtaining processing-related data on powdered thermosetting resins has been investigated. The method involved viscosity measurements obtained with a small specimen (less than 100 mg) parallel plate plastometer. A data acquisition and reduction system was developed which provided a value of viscosity and strain rate about 12-13 second intervals during a test. The effects of specimen compaction pressure and reduction of adhesion between specimen and parallel plates were examined. The plastometer was used to measure some processing-related viscosity changes of an addition polyimide resin, including changes caused by pre-test heat treatment, test temperature, and strain rate.

  17. Thermal behavior of halogenated imidebismaleimide resins

    International Nuclear Information System (INIS)

    Mohammad, A.; Al-Halim, N.Z.

    1995-01-01

    Several new poly-halogenated malecimides, bismaleimides and therir copoly resins were synthessised thermally from their corresponding amic acids. The synthesis was accomplished by two way method (amic acid-polimide) instead of the well-known three way method (amic acid-imide-polyimide). Thermal characterization of monomers and their cured resins was achieved using differential thermal analysis (DTA), dynamic thermogravimetric analysis (TGA) and isothermal gravimetric analysis (IGA). The effect of halogen substituent, especially in the ortho postion, is clear in the imidization proces, while polymerization proceeds almost equally in all systems. Thermal properties of homo and copolymers were correlated with their chemical structures. (author). 15 refs., 4

  18. Understanding of the color in composite resin

    Directory of Open Access Journals (Sweden)

    Jeong-Won Park

    2011-07-01

    Full Text Available In clinic, esthetic restoration of a defective natural tooth with composite resin is challenging procedure and needs complete understanding of the color of tooth itself and materials used. The optical characteristics of the composites are different because the chemical compositions and microstructures are not same. This review provided basic knowledge of the color and the color measurement devices, and analyze the color of the natural tooth. Further, the accuracy of the shade tab, color of the composite resins before and after curing, effect of the water, food and bleaching agent, and translucency, opalescence, and fluorescence effects were evaluated.

  19. Study on the Novel Dicyanate Ester Resin Containing Naphthalene Unit

    Institute of Scientific and Technical Information of China (English)

    Hong Qiang YAN; Hong Yun PENG; Li JI; Guo Rong QI

    2004-01-01

    The novel dicyanate ester resin containing naphthalene unit (DNCY) was synthesized, and characterized by FT-IR, 1H-NMR, 13C-NMR and elemental analysis (EA).The thermal properties of DNCY resin was studied by thermal degradation analysis at a heating rate of 10 (C /min-1 in N2 and air. The DNCY resin exhibited better thermal and thermal-oxidative stability than bisphenol A dicyanate (BACY) resin.

  20. Modification of Aliphatic Petroleum Resin by Peracetic Acid

    OpenAIRE

    Bondaletov, Vladimir Grigoryevich; Bondaletova, Lyudmila Ivanovna; Hamlenko, A.; Bondaletov, Oleg Vladimirovich; Starovoit, M.

    2014-01-01

    This work demonstrates the possibility of obtaining modified aliphatic resin (PRC5) by means of petroleum resin oxidation by peracetic acid. We have experimentally determined oxidation conditions that lead to producing resin with maximum epoxy and acid numbers. Ratio of "oxidative system: PRC5" is 0.5:1, process duration is 2 hours. The modified resin structure is determined by IR and NMR spectroscopy.

  1. Performances and improvement of copper-hydrazine complexation deoxidising resin

    International Nuclear Information System (INIS)

    Liu Fenfen; Zhang Hao; Sun Haijun; Liu Xiaojie

    2012-01-01

    Copper-hydrazine complexation deoxidising resin is tested to examine its performances including effluent water quality and capacity of deoxidisation. By the means of changing the resin type and regeneration, the deoxidising capacity of the resin can be improved to 13 times more than before. At the same time, physical performances of the resin are also greatly improved while maintaining its velocity of deoxidisation and effluent quality. (authors)

  2. Recovery of tretrachloroaurate through ion exchange with Dowex 11 resin

    International Nuclear Information System (INIS)

    Alguacil, F.J.

    1998-01-01

    The recovery of the tretrachloroaurate complex by the anionic ion exchange resin Dowex 11 has been studied. The kinetics of gold adsorption were dependent of both gold and resin concentrations and temperature. The adsorption isotherm can be described by the expression Q=kC''n. The loaded resin could be eluted by an acidic thiourea solution at 20 degree centigree. After several adsorption-elution cycles there is not any apparent loss in the adsorption properties of the resin. (Author) 6 refs

  3. Management of white spots: resin infiltration technique and microabrasion

    Directory of Open Access Journals (Sweden)

    Jeong-Hye Son

    2011-01-01

    Full Text Available This case report compared the effectiveness of resin infiltration technique (Icon, DMG with microabrasion (Opalustre, Ultradent Products, Inc. in management of white spot lesions. It demonstrates that although neither microabrasion nor resin infiltration technique can remove white spot lesions completely, resin infiltration technique seems to be more effective than microabrasion. Therefore resin infiltration technique can be chosen preferentially for management of white spot lesions and caution should be taken for case selection.

  4. Evaluation of an Experimental Adhesive Resin for Orthodontic Bonding

    Science.gov (United States)

    Durgesh, B. H.; Alkheraif, A. A.; Pavithra, D.; Hashem, M. I.; Alkhudhairy, F.; Elsharawy, M.; Divakar, D. D.; Vallittu, P. K.; Matinlinna, J. P.

    2017-07-01

    The aim of this study was to evaluate in vitro the effect of an experimental adhesive resin for orthodontic bonding by measuring some the chemical and mechanical properties. The resin demonstrated increased values of nanohardness and elastic modulus, but the differences were not significant compared with those for the Transbond XT adhesives. The experimental adhesive resin could be a feasible choice or a substitute for the traditional bis-GMA-based resins used in bonding orthodontic attachments.

  5. 40 CFR 414.50 - Applicability; description of the thermosetting resins subcategory.

    Science.gov (United States)

    2010-07-01

    ... thermosetting resins subcategory. 414.50 Section 414.50 Protection of Environment ENVIRONMENTAL PROTECTION... Thermosetting Resins § 414.50 Applicability; description of the thermosetting resins subcategory. The provisions... the products classified under SIC 28214 thermosetting resins including those resins and resin groups...

  6. The influence of resin flexural modulus on the magnitude of ceramic strengthening.

    LENUS (Irish Health Repository)

    Fleming, Garry J P

    2012-07-01

    The aim was to determine the magnitude of ceramic resin-strengthening with resin-based materials with varying flexural moduli using a regression technique to assess the theoretical strengthening at a \\'zero\\' resin-coating thickness. The hypothesis tested was that experimentally, increasing resin flexural modulus results in increased resin-strengthening observed at a theoretical \\'zero\\' resin-coating thickness.

  7. Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin

    Directory of Open Access Journals (Sweden)

    H. Kimura

    2011-12-01

    Full Text Available Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin were investigated. The cure behavior of benzoxazine with cyanate ester resin was monitored by model reaction using nuclear magnetic resonance (NMR. As a result of the model reaction, the ring opening reaction of benzoxazine ring and thermal self-cyclotrimerization of cyanate ester group occurred, and then the phenolic hydoroxyl group generated by the ring opening reaction of benzoxazine ring co-reacted with cyanate ester group. The properties of the cured thermosetting resin were estimated by mechanical properties, electrical resistivity, water resistance and heat resistance. The cured thermosetting resin from benzoxazine and cyanate ester resin showed good heat resistance, high electrical resistivity and high water resistance, compared with the cured thermosetting resin from benzoxazine and epoxy resin.

  8. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  9. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a water...

  10. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  11. 75 FR 67105 - Granular Polytetrafluoroethylene Resin From Italy and Japan

    Science.gov (United States)

    2010-11-01

    ... Polytetrafluoroethylene Resin From Italy and Japan AGENCY: United States International Trade Commission. ACTION... resin from Italy and Japan. SUMMARY: The Commission hereby gives notice that it has instituted reviews... revocation of the antidumping duty orders on granular polytetrafluoroethylene resin from Italy and Japan...

  12. 21 CFR 872.3670 - Resin impression tray material.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin impression tray material. 872.3670 Section...

  13. 40 CFR 721.5762 - Aromatic aldehyde phenolic resin (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Aromatic aldehyde phenolic resin... Specific Chemical Substances § 721.5762 Aromatic aldehyde phenolic resin (generic). (a) Chemical substance... aromatic aldehyde phenolic resin (PMN P-01-573) is subject to reporting under this section for the...

  14. 21 CFR 177.2410 - Phenolic resins in molded articles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Phenolic resins in molded articles. 177.2410... as Components of Articles Intended for Repeated Use § 177.2410 Phenolic resins in molded articles. Phenolic resins identified in this section may be safely used as the food-contact surface of molded...

  15. Evaluation of some anionic exchange resins as potential tablet ...

    African Journals Online (AJOL)

    The effect of resin concentration and compression force on the properties of tablets using the selected resin was investigated. In addition, the disintegrant efficacy of the selected resin in the tablet formulations containing either a basic drug, e.g., dextromethorphan hydrobromide (DMP), or an acidic drug, e.g., diclofenac ...

  16. Development of radiation-curable resin based on natural rubber

    Energy Technology Data Exchange (ETDEWEB)

    Mohd, Dahlan; Harun, Abdul Ghani [Nuclear Energy Unit, Bangi, Selangor (Malaysia)

    1994-12-31

    A new radiation curable resin based on natural rubber has been developed. The resin was based on the reaction between low molecular weight epoxidised natural rubber and acrylic acid. When formulated with reactive monomers and photoinitiator, it solidified upon irradiation with UV light. The resin may find applications in coating for cellulosic-based substrates and pressure-sensitive adhesive.

  17. 21 CFR 177.2430 - Polyether resins, chlorinated.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyether resins, chlorinated. 177.2430 Section 177... Components of Articles Intended for Repeated Use § 177.2430 Polyether resins, chlorinated. Chlorinated polyether resins may be safely used as articles or components of articles intended for repeated use in...

  18. Development of radiation-curable resin based on natural rubber

    International Nuclear Information System (INIS)

    Dahlan Mohd; Abdul Ghani Harun

    1993-01-01

    A new radiation curable resin based on natural rubber has been developed. The resin was based on the reaction between low molecular weight epoxidised natural rubber and acrylic acid. When formulated with reactive monomers and photoinitiator, it solidified upon irradiation with UV light. The resin may find applications in coating for cellulosic-based substrates and pressure-sensitive adhesive

  19. Color change of composite resins subjected to accelerated artificial aging

    Directory of Open Access Journals (Sweden)

    Denise Cremonezzi Tornavoi

    2013-01-01

    Conclusions: All composite resins presented unacceptable color changes after 382 h of aging and different composite resins with same hue, presented different colors before being subjected to the aging process (B2 and C2 and after (B2. It was also observed color difference within a group of the same composite resin and same hue.

  20. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  1. Plutonium titration by controlled potential coulometry; Dosage du plutonium par coulometrie a potentiel impose

    Energy Technology Data Exchange (ETDEWEB)

    Leguay, N.

    2011-07-01

    The LAMMAN (Nuclear Materials Metrology Laboratory) is the support laboratory of the CETAMA (Analytical Method Committee), whose two main activities are developing analytic methods, and making and characterizing reference materials. The LAMMAN chose to develop the controlled potential coulometry because it is a very accurate analytical technique which allows the connection between the quantity of element electrolysed to the quantity of electricity measured thanks to the Faraday's law: it does not require the use of a chemical standard. This method was first used for the plutonium titration and was developed in the Materials Analysis and Metrology Laboratory (LAMM), for upgrading its performances and developing it to the titration of other actinides. The equipment and the material used were developed to allow the work in confined atmosphere (in a glove box), with all the restrictions involved. Plutonium standard solutions are used to qualify the method, and in particular to do titrations with an uncertainty better than 0.1 %. The present study allowed making a bibliographic research about controlled potential coulometry applied to the actinides (plutonium, uranium, neptunium, americium and curium). A full procedure was written to set all the steps of plutonium titration, from the preparation of samples to equipments storage. A method validation was done to check the full procedure, and the experimental conditions: working range, uncertainty, performance... Coulometric titration of the plutonium from pure solution (without interfering elements) was developed to the coulometric titration of the plutonium in presence of uranium, which allows to do accurate analyses for the analyses of some parts of the reprocessing of the spent nuclear fuel. The possibility of developing this method to other actinides than plutonium was highlighted thanks to voltammetric studies, like the coulometric titration of uranium with a working carbon electrode in sulphuric medium. (author)

  2. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    Science.gov (United States)

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  3. Titrated flow versus fixed flow Bubble Nasal CPAP for respiratory distress in preterm neonates.

    Directory of Open Access Journals (Sweden)

    Srinivas eMurki

    2015-10-01

    Full Text Available Background: The clinical effects of a pre-fixed flow of air-oxygen versus a flow titrated according to visible bubbling are not well understood.Objective: To compare the effects of a fixed flow (5 L/min and titrated flow ( flow just enough to ensure bubbling at different set pressures on delivered intra-prong pressure, gas exchange and clinical parameters in preterm infants on bubble CPAP for respiratory distress.Methods: Preterm infants less than 35 weeks gestation on bubble CPAP and less than 96 h of age, were enrolled in this cross over study. They were subjected to 30 minute periods of titrated flow and fixed flow. At the end of both epochs, gas flow rate, set pressure, FiO2, SpO2, Silverman retraction score, respiratory rate , abdominal girth, and blood gases were recorded. The delivered intra-prong pressure was measured by an electronic manometer. Results: Sixty nine recordings were made in 54 infants. For each of the set CPAP pressures (4, 5 and 6 cm H2O, the mean delivered pressure with a fixed flow of 5 L/min was higher than that delivered by the titrated flow. During the fixed flow epoch, the delivered pressure was closer to and higher than the set pressure resulting in higher PaO2 and lower PaCO2 as compared to titrated flow epoch. In the titrated flow period, the delivered pressure was consistently lower than the set pressure. Conclusion: In preterm infants on bubble CPAP with set pressures of 4 to 6 cm H2O, a fixed flow of 5 L/min is more effective than a flow titrated to ensure adequate visible bubbling. It achieves higher delivered pressures, better oxygenation and ventilation.

  4. Potentiometric titration of selenic and telluric acids with titanium(III) chloride in nonaqueous solvents

    International Nuclear Information System (INIS)

    Yoshimura, Chozo; Miyamoto, Kiyoshige

    1985-01-01

    Selenic and Telluric acids were titrated potentiometrically with titanium(III) chloride solution by using Pt-Cu · Hg bimetallic electrodes in nonaqueous solvents such as N, N-dimethyl-formamide (DMF), dimethyl sulfoxide (DMSO), isopropyl alcohol (IPA) and the mixtures of these solvents. It was found that selenic and telluric acids were titrated directly at room temperature in DMF solution without hydrochloric acid. The molar ratios of selenic and telluric acids to titanium(III) chloride was 1 : 6. However, the corresponding reactions to SeO 4 2- → SeO 3 2- or TeO 4 2- → TeO 3 2- were not confirmed in the titration curve in DMF. In the titration of selenic acid in mixed solvents of DMF and IPA in 1 : 1 or 1 : 2 ratio, two steps were observed. The first and the second steps were appeared on the titration curve at molar ratios of 1 : 2 and 1 : 6, respectively. It was interpreted that the first step corresponded to the intermediate reaction of SeO 4 2- → SeO 3 2- . Mixed solution of selenic and telluric acids were determined by the proposed method. Three steps were observed on the titration curve. It was interpreted that the first, second and third steps corresponded to the reaction of SeO 4 2- → SeO 3 2- , SeO 3 2- → Se(0), and TeO 4 2- → Te(0), respectively. Less than 5 % of water gave no influence on the titration. (author)

  5. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  6. NASA SPoRT JPSS PG Activities in Alaska

    Science.gov (United States)

    Berndt, Emily; Molthan, Andrew; Fuell, Kevin; McGrath, Kevin; Smith, Matt; LaFontaine, Frank; Leroy, Anita; White, Kris

    2018-01-01

    SPoRT (NASA's Short-term Prediction Research and Transition Center) has collaboratively worked with Alaska WFOs (Weather Forecast Offices) to introduce RGB (Red/Green/Blue false color image) imagery to prepare for NOAA-20 (National Oceanic and Atmospheric Administration, JPSS (Joint Polar Satellite System) series-20 satellite) VIIRS (Visible Infrared Imaging Radiometer Suite) and improve forecasting aviation-related hazards. Last R2O/O2R (Research-to-Operations/Operations-to-Research) steps include incorporating NOAA-20 VIIRS in RGB suite and fully transitioning client-side RGB processing to GINA (Geographic Information Network of Alaska) and Alaska Region. Alaska Region WFOs have been part of the successful R2O/O2R story to assess the use of NESDIS (National Environmental Satellite, Data, and Information Service) Snowfall Rate product in operations. SPoRT introduced passive microwave rain rate and IMERG (Integrated Multi-satellitE Retrievals for GPM (Global Precipitation Measurement)) (IMERG) to Alaska WFOs for use in radar-void areas and assessing flooding potential. SPoRT has been part of the multi-organization collaborative effort to introduce Gridded NUCAPS (NOAA Unique CrIS/ATMS (Crosstrack Infrared Sounder/Advanced Technology Microwave Sounder) Processing System) to the Anchorage CWSU (Center Weather Service Unit) to assess Cold Air Aloft events, [and as part of NOAA's PG (Product Generation) effort].

  7. WE-H-207B-04: Strategies for Adaptive RT

    Energy Technology Data Exchange (ETDEWEB)

    Green, O. [Washington University School of Medicine (United States)

    2016-06-15

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

  8. WE-H-207B-00: MRgRT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

  9. GOKaRT: Graphical Online Search Tool for Maps

    Directory of Open Access Journals (Sweden)

    Mechthild Schüler

    2008-09-01

    Full Text Available The map department of the Staats- und Universitätsbibliothek Göttingen together with the Berlin State Library propose a project to develop a web-based graphic cataloguing and search system for maps, to be funded by the German Research Foundation. This tool shall be made available to all map holdings in archives, libraries, university departments and museums in Germany as a comfortable means for the administration of map holdings and as a search tool. Sheets belonging to map series as well as single maps (old and new will be registered cooperatively by the participants with simple tools. This cooperation in data maintenance will facilitate the work especially for understaffed map holdings. Depending on the type of map there are four different mechanisms for map reference. For map series electronic index sheets are used which will show information regarding the various issues of the map sheets. Due to the intuitive graphic search entry GOKaRT-users will easily find the required maps of a certain region available in a chosen holding. User administration modules ensure comfortable handling. GOKaRT is being developed on the basis of licence-free open source programmes. In case financing is provided by the German Research Foundation, GOKaRT can be used free of charge internationally. This would require a contract stipulating data exchange between the partners as well as permanent storage and usability of the data.

  10. WE-H-207B-00: MRgRT

    International Nuclear Information System (INIS)

    2016-01-01

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A

  11. WE-H-207B-04: Strategies for Adaptive RT

    International Nuclear Information System (INIS)

    Green, O.

    2016-01-01

    In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A

  12. Resin Flow in Fiber Preformed by Vacuum Assisted Resin Transfer Molding with Flexible Tools

    Directory of Open Access Journals (Sweden)

    M.M. Shokrieh

    2008-12-01

    Full Text Available Vacuum assisted resin transfer molding, as a sub-branch of RTM is a method of manufacturing composite specimens. Considering the industrial development of this method, different modified techniques are designed to improve its performance. Among these techniques, using a half flexible mold is regarded as an important method. In this work, dominant equations of resin flow through the mold in polar coordinates are solved analytically. Based on this approach, closed-form solutions have been presented for different parameters such as thickness variation of preformed fiber, resin pressure, resin velocity and fiber volume fraction as functions of two variables, namely, time and the distance from injection port. After verification of the approach employed in this work, the results are presented. Important parameters influencing the quality and the rate production are studied in detail.

  13. 21 CFR 177.1555 - Polyarylate resins.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Polyarylate resins. 177.1555 Section 177.1555 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... in contact with all foods except beverages containing more than 8 volume percent ethanol under...

  14. Microbial treatment of ion exchange resins

    International Nuclear Information System (INIS)

    Kouznetsov, A.; Kniazev, O.

    2001-01-01

    A bioavailability of ion exchange resins to a microbial destruction as one of the alternative methods of compacting used ionites from the nuclear fuel manufacturing cycle enterprises has been investigated. The bio-destruction was studied after a preliminary chemical treatment or without it. A sensitivity of the ion exchange resins (including highly acidic cationite KU-2-8) to the microbial destruction by heterotrophic and chemo-litho-trophic microorganisms under aerobic conditions was shown in principle. The biodegradation of the original polymer is possible in the presence of the water soluble fraction of the resin obtained after its treatment by Fenton reagent and accelerated in the presence of Mn-ions in optimal concentration 1-2 g of Mn per liter of medium. Thus, the process of bio-destruction of ionite polymer by heterotrophic microorganisms can be compared with the bio-destruction of lignin or humic substances. The optimum parameters of bio-destruction and microorganisms used must be different for resins with different functional groups. (authors)

  15. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  16. Studies on chemoviscosity modeling for thermosetting resins

    Science.gov (United States)

    Bai, J. M.; Hou, T. H.; Tiwari, S. N.

    1987-01-01

    A new analytical model for simulating chemoviscosity of thermosetting resins has been formulated. The model is developed by modifying the well-established Williams-Landel-Ferry (WLF) theory in polymer rheology for thermoplastic materials. By introducing a relationship between the glass transition temperature Tg(t) and the degree of cure alpha(t) of the resin system under cure, the WLF theory can be modified to account for the factor of reaction time. Temperature dependent functions of the modified WLF theory constants C sub 1 (t) and C sub 2 (t) were determined from the isothermal cure data. Theoretical predictions of the model for the resin under dynamic heating cure cycles were shown to compare favorably with the experimental data. This work represents progress toward establishing a chemoviscosity model which is capable of not only describing viscosity profiles accurately under various cure cycles, but also correlating viscosity data to the changes of physical properties associated with the structural transformation of the thermosetting resin systems during cure.

  17. 21 CFR 177.1585 - Polyestercarbonate resins.

    Science.gov (United States)

    2010-04-01

    .... Polyestercarbonate resins may be safely used as articles or components of articles intended for use in producing.... Copies are available from the Office of Premarket Approval, Center for Food Safety and Applied Nutrition... examined at the Center for Food Safety and Applied Nutrition's Library, Food and Drug Administration, 5100...

  18. Effect of Resin Extract from Commiphora swynnertonii

    African Journals Online (AJOL)

    Dr Olaleye

    of Commiphora swynnertonii resin on biochemical parameters in rats was investigated. Sixty rats were ... significantly elevated protein and albumin levels but had no significant effect on bilirubin and all the liver enzymes in the rats. These findings are ... hypoglycemic and hypolipidemic effects against high fat diet- induced ...

  19. Evaluation of resins for use in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Luiz Claudio F.M. Garcia; Ferraz, Wilmar Barbosa; Chrcanovic, Bruno Ramos; Santos, Ana Maria M., E-mail: ferrazw@cdtn.b, E-mail: amms@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Prostate cancer can be treated with interstitial brachytherapy in initial stage of the disease in which tiny radioactive seeds with cylindrical geometry are used. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation, a radionuclide carrier, and X-ray marker. Among the materials that have potential for innovation in the construction of seeds, biocompatible resins appear as an important option. In this paper, we present some characterization results with Fourier transform infrared spectroscopic (FTIR) and ultraviolet-visible spectroscopy (UV-vis) performed on two types of resins in which curing temperatures for each one were varied as also the results of coatings with these resins under titanium substrates. Interactions of these resins in contact with the simulated body fluid were evaluated by atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. (author)

  20. System of programming units for the K556RT4 and K556RT5 fixed programmed memory devices

    International Nuclear Information System (INIS)

    Bobkov, S.G.; Ermolin, Yu.V.; Kantserov, V.A.; Strigin, V.B.

    1983-01-01

    The programming system of constant programmable memory devices K556RT4 and K556RT5 that consist of two units (a programming device and an electrothermotraining unit) is described. The modules are made in the KAMAK standard. The programming device takes up 2 normal places, while the electrothermotraining block takes up 1 place. As information recording is done using a computer the time for programming is reduced and the possibility of errors is limited as compared with the manual method. The computer introduces the whole word to be recorded, not the separate parts, in the programming device. The transition to a new digit of a given word in the programming device is done automatically. This reduces the expense of computer time and accelerates the programming of microdiagrams

  1. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    Science.gov (United States)

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This

  2. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    Science.gov (United States)

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences

  3. ANALYSIS OF VENTING OF A RESIN SLURRY

    Energy Technology Data Exchange (ETDEWEB)

    Laurinat, J.; Hensel, S.

    2012-03-27

    A resin slurry venting analysis was conducted to address safety issues associated with overpressurization of ion exchange columns used in the Purex process at the Savannah River Site (SRS). If flow to these columns were inadvertently interrupted, an exothermic runaway reaction could occur between the ion exchange resin and the nitric acid used in the feed stream. The nitric acid-resin reaction generates significant quantities of noncondensable gases, which would pressurize the column. To prevent the column from rupturing during such events, rupture disks are installed on the column vent lines. The venting analysis models accelerating rate calorimeter (ARC) tests and data from tests that were performed in a vented test vessel with a rupture disk. The tests showed that the pressure inside the test vessel continued to increase after the rupture disk opened, though at a slower rate than prior to the rupture. Calculated maximum discharge rates for the resin venting tests exceeded the measured rates of gas generation, so the vent size was sufficient to relieve the pressure in the test vessel if the vent flow rate was constant. The increase in the vessel pressure is modeled as a transient phenomenon associated with expansion of the resin slurry/gas mixture upon rupture of the disk. It is postulated that the maximum pressure at the end of this expansion is limited by energy minimization to approximately 1.5 times the rupture disk burst pressure. The magnitude of this pressure increase is consistent with the measured pressure transients. The results of this analysis demonstrate the need to allow for a margin between the design pressure and the rupture disk burst pressure in similar applications.

  4. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Janot, N.; Benedetti, M. F. [Univ Paris Diderot, Lab Geochim Eaux, UMR CNRS 7154, IPGP, F-75025 Paris 13 (France); Janot, N.; Reiller, P. E. [CE Saclay, CEA DEN DANS DPC SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Korshin, G. V. [Univ Washington, Dept Civil and Environm Engn, Seattle, WA 98195 (United States)

    2010-07-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM ({>=}1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  5. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    International Nuclear Information System (INIS)

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  6. A stable and convenient protein electrophoresis titration device with bubble removing system.

    Science.gov (United States)

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Standardized comparison of the relative impacts of HIV-1 reverse transcriptase (RT) mutations on nucleoside RT inhibitor susceptibility.

    Science.gov (United States)

    Melikian, George L; Rhee, Soo-Yon; Taylor, Jonathan; Fessel, W Jeffrey; Kaufman, David; Towner, William; Troia-Cancio, Paolo V; Zolopa, Andrew; Robbins, Gregory K; Kagan, Ron; Israelski, Dennis; Shafer, Robert W

    2012-05-01

    Determining the phenotypic impacts of reverse transcriptase (RT) mutations on individual nucleoside RT inhibitors (NRTIs) has remained a statistical challenge because clinical NRTI-resistant HIV-1 isolates usually contain multiple mutations, often in complex patterns, complicating the task of determining the relative contribution of each mutation to HIV drug resistance. Furthermore, the NRTIs have highly variable dynamic susceptibility ranges, making it difficult to determine the relative effect of an RT mutation on susceptibility to different NRTIs. In this study, we analyzed 1,273 genotyped HIV-1 isolates for which phenotypic results were obtained using the PhenoSense assay (Monogram, South San Francisco, CA). We used a parsimonious feature selection algorithm, LASSO, to assess the possible contributions of 177 mutations that occurred in 10 or more isolates in our data set. We then used least-squares regression to quantify the impact of each LASSO-selected mutation on each NRTI. Our study provides a comprehensive view of the most common NRTI resistance mutations. Because our results were standardized, the study provides the first analysis that quantifies the relative phenotypic effects of NRTI resistance mutations on each of the NRTIs. In addition, the study contains new findings on the relative impacts of thymidine analog mutations (TAMs) on susceptibility to abacavir and tenofovir; the impacts of several known but incompletely characterized mutations, including E40F, V75T, Y115F, and K219R; and a tentative role in reduced NRTI susceptibility for K64H, a novel NRTI resistance mutation.

  8. The Mobile Insulin Titration Intervention (MITI) for Insulin Glargine Titration in an Urban, Low-Income Population: Randomized Controlled Trial Protocol.

    Science.gov (United States)

    Levy, Natalie; Moynihan, Victoria; Nilo, Annielyn; Singer, Karyn; Bernik, Lidia S; Etiebet, Mary-Ann; Fang, Yixin; Cho, James; Natarajan, Sundar

    2015-03-13

    Patients on insulin glargine typically visit a clinician to obtain advice on how to adjust their insulin dose. These multiple clinic visits can be costly and time-consuming, particularly for low-income patients. It may be feasible to achieve insulin titration through text messages and phone calls with patients instead of face-to-face clinic visits. The objectives of this study are to (1) evaluate if the Mobile Insulin Titration Intervention (MITI) is clinically effective by helping patients reach their optimal dose of insulin glargine, (2) determine if the intervention is feasible within the setting and population, (3) assess patient satisfaction with the intervention, and (4) measure the costs associated with this intervention. This is a pilot study evaluating an approach to insulin titration using text messages and phone calls among patients with insulin-dependent type 2 diabetes in the outpatient medical clinic of Bellevue Hospital Center, a safety-net hospital in New York City. Patients will be randomized in a 1:1 ratio to either the MITI arm (texting/phone call intervention) or the usual-care arm (in-person clinic visits). Using a Web-based platform, weekday text messages will be sent to patients in the MITI arm, asking them to text back their fasting blood glucose values. In addition to daily reviews for alarm values, a clinician will rereview the texted values weekly, consult our physician-approved titration algorithm, and call the patients with advice on how to adjust their insulin dose. The primary outcome will be whether or not a patient reaches his/her optimal dose of insulin glargine within 12 weeks. Recruitment for this study occurred between June 2013 and December 2014. We are continuing to collect intervention and follow-up data from our patients who are currently enrolled. The results of our data analysis are expected to be available in 2015. This study explores the use of widely-available text messaging and voice technologies for insulin titration

  9. Incineration of ion exchange resins using concentric burners

    International Nuclear Information System (INIS)

    Fukasawa, T.; Chino, K.; Kawamura, F.; Kuriyama, O.; Yusa, H.

    1985-01-01

    A new incineration method, using concentric burners, is studied to reduce the volume of spent ion exchange resins generated from nuclear power plants. Resins are ejected into the center of a propane-oxygen flame and burned within it. The flame length is theoretically evaluated by the diffusion-dominant model. By reforming the burner shape, flame length can be reduced by one-half. The decomposition ratio decreases with larger resin diameters due to the loss of unburned resin from the flame. A flame guide tube is adapted to increase resin holding time in the flame, which improves the decomposition ratio to over 98 wt%

  10. Method for curing alkyd resin compositions by applying ionizing radiation

    International Nuclear Information System (INIS)

    Watanabe, T.; Murata, K.; Maruyama, T.

    1975-01-01

    An alkyd resin composition is prepared by dissolving a polymerizable alkyd resin having from 10 to 50 percent of oil length into a vinyl monomer. The polymerizable alkyd resin is obtained by a half-esterification reaction of an acid anhydride having a polymerizable unsaturated group and an alkyd resin modified with conjugated unsaturated oil having at least one reactive hydroxyl group per one molecule. The alkyd resin composition thus obtained is coated on an article, and ionizing radiation is applied on the article to cure the coated film thereon. (U.S.)

  11. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  12. Quantitative Determination of NTA and Other Chelating Agents in Detergents by Potentiometric Titration with Copper Ion Selective Electrode.

    Science.gov (United States)

    Ito, Sana; Morita, Masaki

    2016-01-01

    Quantitative analysis of nitrilotriacetate (NTA) in detergents by titration with Cu 2+ solution using a copper ion selective electrode was achieved. This method tolerates a wide range of pH and ingredients in detergents. In addition to NTA, other chelating agents, having relatively lower stability constants toward Cu 2+ , were also qualified with sufficient accuracy by this analytical method for model detergent formulations. The titration process was automated by automatic titrating systems available commercially.

  13. Online Automatic Titration of Chromic Acid in Chromium Plating Solutions and Phosphoric and Sulfuric Acids in Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1991-01-01

    .... The analytical chemistry literature lacks an adequate online automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric...

  14. Linear titration plot for the determination of boron in the primary coolant of a pressurized water reactor

    International Nuclear Information System (INIS)

    Midgley, D.; Gatford, C.

    1992-01-01

    A linear titration plot method has been devised for the determination of boron as boric acid in partly neutralized solution, such as occurs in the primary coolant of pressurized water reactors. The total boron and the alkali in the sample are determined simultaneously. Although it is not essential to add mannitol in this method, it is more accurate when the solution is saturated with mannitol. Comparisons are made with other modes of titration: Gran plots, first and second differential potentiometric titrations and indicator titrations. None of these gives the total boron directly in partly neutralized solutions. (author)

  15. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    Science.gov (United States)

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Method of burning ion-exchange resin contaminated with radioactivity

    International Nuclear Information System (INIS)

    Suzuki, Shigenori.

    1986-01-01

    Purpose: To process spent ion exchange resins to reduce their volume, without increasing the load on a off-gas system and in a stable state and at the same time not leaving any uncombusted portions. Method: The water slurries of the ion exchange resins contaminated with radioactive materials is dehydrated or dry combusted to reduce the water content. A binder is then added to solidify the ion exchange resin. The solidified ion exchange resins are then combusted in a furnace. This prevents the ion exchange resin from being dispersed by air and combustion gases. Furthermore, the solidified ion exchange resins in the form of small pellets burn from the surface inwards. Moreover the binder is carbonized by the combustion heat and promotes combustion to convert the ion exchange resins into a solid mass, making sure that no uncombusted portion is left. (Takahashi, M.)

  17. Commercial Ion Exchange Resin Vitrification in Borosilicate Glass

    International Nuclear Information System (INIS)

    Cicero-Herman, C.A.; Workman, P.; Poole, K.; Erich, D.; Harden, J.

    1998-05-01

    Bench-scale studies were performed to determine the feasibility of vitrification treatment of six resins representative of those used in the commercial nuclear industry. Each resin was successfully immobilized using the same proprietary borosilicate glass formulation. Waste loadings varied from 38 to 70 g of resin/100 g of glass produced depending on the particular resin, with volume reductions of 28 percent to 68 percent. The bench-scale results were used to perform a melter demonstration with one of the resins at the Clemson Environmental Technologies Laboratory (CETL). The resin used was a weakly acidic meth acrylic cation exchange resin. The vitrification process utilized represented a approximately 64 percent volume reduction. Glass characterization, radionuclide retention, offgas analyses, and system compatibility results will be discussed in this paper

  18. Comparison of Mechanical Properties of Resin Composites with Resin Modified Glass Ionomers

    Directory of Open Access Journals (Sweden)

    Taha NA

    2015-06-01

    Full Text Available Statement of Problem: There are controversial reports regarding physical and mechanical properties of resin composites and glass ionomer cements. Some revealed higher strength and hardness for resin composites while others showed a comparable value for glass ionomer cements. Evaluation of mechanical properties of different types of resin composites in comparison with resin modified glass ionomers is not widely studied. Objectives: To measure and compare the flexural strength and Vickers hardness of three resin composites and two resins modified glass ionomer cements before and after ageing. Materials and Methods: Three resin composites, i.e. Filtek Supreme XTE (3M ESPE, Ice (SDI, Gradia (GC, and two resins modified glass ionomers, i.e. Fuji II LC (GC and Riva Light Cure (SDI, were selected. Ten barshaped specimens were prepared for each material and cured using LED curing light. After 24 hours storage in distilled water at 37oC, the specimens were randomly divided into two equal groups (n=5. The first group was tested as a baseline and the second group was restored at 37oC for another 29 days. Flexural strength was performed by four-point bending test using universal testing machine at crosshead speed of 0.5mm/min, and the maximum load at failure was recorded. The specimen’s halves were used for evaluating Vickers hardness, using a Digital Hardness Tester (300 g/15 sec and the Vickers hardness number (VHN was recorded. Data were analyzed using one-way analysis of variance (ANOVA, Tukey’s and student’s t-test. Results: After 24 hours of immersion, the highest hardness number was found for Filtek Supreme and Ice and the highest flexural strength was obtained for Gradia. After 30 days of storage, hardness of Fuji II LC and Gradia showed a significant decrease; flexural strength of Ice and Fuji II LC revealed a significant increase while Gradia and Filtek Supreme showed a significant decrease. Conclusions: Resin modified glass ionomers showed

  19. [Physical properties of resins for veneer crown. (Part 1) Bending strength of thermosetting methacrylic resins (author's transl)].

    Science.gov (United States)

    Kashiwada, T

    1979-01-01

    The physical properties of thermosetting methacrylic resins contain a kind or more than two kinds of cross linking agents were investigated. Knoop hardness and bending strength after drying, water sorption and thermal cycling were listed in table 4 and 5. Hydrophilic resins absorbed water about 3 times as much as hydrophobic resins. The materials contain a small amount of hydrophobic cross linking agents in MMA indicate comparatively excellent properties after drying, water sorption and thermal cycling. Knoop hardness of resins generally reduced by water sorption, especially in the case of the resin contains a large amount of triethylene glycol dimethacrylate.

  20. SYNTHESIS OF AZO COMPOUNDS DERIVATIVE FROM EUGENOL AND ITS APPLICATION AS A TITRATION INDICATOR

    Directory of Open Access Journals (Sweden)

    Bambang Purwono

    2010-06-01

    Full Text Available The synthesis of azo compounds from eugenol has been carried out by diazotation reaction. The diazonium salt was produced by reaction of aniline and sodium nitrite in acid condition at 0-5 °C temperature to yield benzenediazonium chloride salt. The salt was then reacted with eugenol to produce the azo derivatives. The azo product was analyzed by IR, 1H-NMR, dan GC-MS spectrometer. The results showed that the reaction of benzenediazonium chloride with eugenol gave 4-allyl-2-methoxy-6-hydroxyazobenzene in 34.27% yield for 30 minutes reaction. The derivative of azo compound was dissolved in ethanol and then the color changing was observed in range of pH 9.8-11.1 from yellow to red. Application for titration indicator for acetic acid titrated with sodium hydroxide showed error less than 3.20% compared with phenol phtaline indicator.   Keywords: Eugenol, Azo compound, titration indicator

  1. Thermometric titration of a free acid and of uranyl in spent fuel element solutions

    International Nuclear Information System (INIS)

    Zamek, M.; Strafelda, F.

    1975-01-01

    A method was elaborated of determining nitric acid in the presence of uranyl nitrate in both aqueous and non-aqueous solutions using a pyridine aqueous solution as a titration agent, and of determining excess uranyl after a hydrogen peroxide addition by a further titration using the same agent. Even a hundred-fold excess of magnesium did not disturb the titration. The method is used in operating solution analyses in the extraction fuel reprocessing in the presence of a small amount of plutonium and of fission products. The reproducibility and accuracy of the method varied in the order of tens to units per cent depending on the concentration of components to be determined. The procedure is applicable for test volumes ranging between 0.1 and 10 ml in concentrations of 1 to 10 -3 M. (author)

  2. [Research on determination of chemical purity of andrographolide by coulometric titration method].

    Science.gov (United States)

    Yang, Ning; Yang, Dezhi; Xu, Lishen; Lv, Yang

    2010-04-01

    The determination of chemical purity of andrographolide by coulometric titration method is studied in this paper. The coulometric titration was carried out in a mixture composed of 4 mol x L(-1) hydrochloric acid and 1 mol x L(-1) potassium bromide solution and 1 mol x L(-1) potassium nitrate solution (1:1). Bromine is electrogenerated at the anode and reacts with the andrographolide. The number of electrons involved in the eleatrode reaction is 2. Purity of andrographolide is 99.76% compared with 99.77% utilizing area normalization method by HPLC. The RSD are 0.33% and 0.02% respectively. The results from two methods are consistent, so the determination of chemical purity of andrographolide by coulometric titration method is scientific and feasible. The method is rapid, simple, convenient, sensitive and accurate. The reference material is not essential in the method. The method is suitable for determination of chemical purity of andrographolide.

  3. Comparing the Titrations of Mixed-Acid Solutions Using Dropwise and Constant-Flow Techniques

    Science.gov (United States)

    Charlesworth, Paul; Seguin, Matthew J.; Chesney, David J.

    2003-11-01

    A mixed-acid solution containing hydrochloric and phosphoric acids was used to determine the error associated with performing a real-time titration. The results were compared against those obtained by performing the titration in a more traditional dropwise addition of titrant near the equivalence points. It was found that the real-time techniques resulted in significantly decreased analysis times while maintaining a low experimental error. The constant-flow techniques were implemented into two different levels of chemistry. It was found that students could successfully utilize the modified experiments. Problems associated with the techniques, major sources of error, and their solutions are discussed. In both cases, the use of the constant-flow setup has increased student recollection of key concepts, such as pKa determination, proper indicator choice, and recognizing the shape of specific titration curves by increasing student interest in the experiment.

  4. Potentiometric Measurement of Transition Ranges and Titration Errors for Acid/Base Indicators

    Science.gov (United States)

    Flowers, Paul A.

    1997-07-01

    Sophomore analytical chemistry courses typically devote a substantial amount of lecture time to acid/base equilibrium theory, and usually include at least one laboratory project employing potentiometric titrations. In an effort to provide students a laboratory experience that more directly supports their classroom discussions on this important topic, an experiment involving potentiometric measurement of transition ranges and titration errors for common acid/base indicators has been developed. The pH and visually-assessed color of a millimolar strong acid/base system are monitored as a function of added titrant volume, and the resultant data plotted to permit determination of the indicator's transition range and associated titration error. Student response is typically quite positive, and the measured quantities correlate reasonably well to literature values.

  5. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts

    International Nuclear Information System (INIS)

    Doi, K.

    1980-01-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDT has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, ΔH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at μ → 0 and μ = 0.5 (NaClO 4 ), respectively. The -ΔH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni. (author)

  6. Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.

    Science.gov (United States)

    Doi, K

    1980-11-01

    The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.

  7. Determination of arsenate and organic arsenic via potentiometric titration of its heteropoly anions.

    Science.gov (United States)

    Metelka, R; Slavíková, S; Vytras, K

    2002-08-16

    Determination of arsenate based on its conversion to molybdoarsenate heteropoly anions followed by potentiometric titration is described. The titration is realized on the ion-pairing principle using cetylpyridinium chloride (or an analogous titrant containing a lipophilic cation), and is monitored by a carbon paste electrode, although other liquid-polymeric membrane-based electrodes can also be used. Calibration plots of the titrant end-point consumption versus concentration of arsenic were constructed and used to evaluate the content of arsenic in aqueous samples. The method could be applied in the analyses of samples with quite low arsenic content (amounts approximately 10 mug As in 50 cm(3) could be titrated). Organic arsenic was determined analogously after the Schöniger combustion of the sample and conversion of its arsenic to arsenate.

  8. Potentiometric titrations of para and nitro substituted aromatic acids and their mixtures in methylethyl ketone

    International Nuclear Information System (INIS)

    Ozeroglu, C.; Karahan, M.

    2011-01-01

    In this study, it was the purpose to examine the potentiometric titrations of para and nitro substituted aromatic acids in methylethyl ketone (MEK) as a non-aqueous solvent. Good analytical results were obtained in determining the amount of each acid and the amounts of acids in their ternary mixtures by using 0.0964 N tetrabuthylammoniumhydroxyde (TBAH) as a standard titrant. Methylethyl ketone (MEK) which is a good solvent for many organic compounds and has a convenient liquid range of -86 to 80 deg. C was used for titration of the para and nitro substituted aromatic acids. A linear relationship has been found between pKa values of the para and nitro substituted aromatic acids in water and the half neutralization potential (HNP) values determined by potentiometric titration curves of the same acids in MEK. (author)

  9. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  10. High frequency titration in non-aqueous solvents. Application to HF and UF6

    International Nuclear Information System (INIS)

    Neveu, Claude

    1965-01-01

    In this research thesis, the author first presents the main theoretical notions regarding high frequency titration, notably by studying characteristic curves, i.e. the titration meter indication with respect to conductibility. He reports the use of this method for the study of various reactions in non-aqueous medium: reaction of AlCl 3 with pyridine in acetonitrile, of AlCl 3 with HCl in tetrachloroethane and in nitromethane. He also reports the attempt of application of this method to the titration of HF in presence of UF 6 in CCl 4 as solvent, or by using F acceptors like BF 3 , PF 5 or ClF 3 as reactants [fr

  11. Oxygen titration in sodium. The mercury method and its use for very low values

    International Nuclear Information System (INIS)

    Champeix, L.; Darras, R.; Duflo, J.

    1958-01-01

    The mercury method for the oxygen titration in sodium has now been known for ten years and is probably the more frequently used. In this text, precision are given to what extent it is valuable when used in microanalysis. Details are given on the apparatus, its manipulation and its calibration. After testing, we have decided to use flame spectroscopy to titrate the sodium hydroxide formed. Discussions are exposed on the errors due to the presence of sodium chloride and calcium. Results are examined from the point of view of their reproducibility and accuracy. If great care is taken, this method allows oxygen titration in sodium even for values below 10 ppm with satisfactory precision. (author) [fr

  12. Development and application of high performance resins for crud removal

    International Nuclear Information System (INIS)

    Deguchi, Tatsuya; Izumi, Takeshi; Hagiwara, Masahiro

    1998-01-01

    The development of crud removal technology has started with the finding of the resin aging effect that an old ion exchange resin, aged by long year of use in the condensate demineralizer, had an enhanced crud removal capability. It was confirmed that some physical properties such as specific surface area and water retention capacity were increased due to degradation caused by long year of contact with active oxygens in the condensate water. So, it was speculated that those degradation in the resin matrix enhanced the adsorption of crud particulate onto the resin surface, hence the crud removal capability. Based on this, crud removal resin with greater surface area was first developed. This resin has shown an excellent crud removal efficiency in an actual power plant, and the crud iron concentration in the condensate effluent was drastically reduced by this application. However, the cross-linkage of the cation resin had to be lowered in a delicate manner for that specific purpose, and this has caused higher organic leachables from the resin, and the sulfate level in the reactor was raised accordingly. Our major goals, therefore, has been to develop a crud resin of as little organic leachables as possible with keeping the original crud removal efficiency. It was revealed through the evaluation of the first generation crud resin and its improved version installed in the actual condensate demineralizers that there was a good correlation between crud removal efficiency and organic leaching rate. The bast one among a number of developmental resins has shown the organic leaching rate of 1/10 of that of the original crud resin (ETR-C), and the crud removal efficiency of 90%. So far as we understand, the resin was considered to have the best overall balance between crud removal and leaching characteristics. The result of six month evaluation of this developmental resin, ETR-C3, in one vessel of condensate demineralizer of a power plant will be presented. (J.P.N.)

  13. Detection and Analysis of Circular RNAs by RT-PCR.

    Science.gov (United States)

    Panda, Amaresh C; Gorospe, Myriam

    2018-03-20

    Gene expression in eukaryotic cells is tightly regulated at the transcriptional and posttranscriptional levels. Posttranscriptional processes, including pre-mRNA splicing, mRNA export, mRNA turnover, and mRNA translation, are controlled by RNA-binding proteins (RBPs) and noncoding (nc)RNAs. The vast family of ncRNAs comprises diverse regulatory RNAs, such as microRNAs and long noncoding (lnc)RNAs, but also the poorly explored class of circular (circ)RNAs. Although first discovered more than three decades ago by electron microscopy, only the advent of high-throughput RNA-sequencing (RNA-seq) and the development of innovative bioinformatic pipelines have begun to allow the systematic identification of circRNAs (Szabo and Salzman, 2016; Panda et al ., 2017b; Panda et al ., 2017c). However, the validation of true circRNAs identified by RNA sequencing requires other molecular biology techniques including reverse transcription (RT) followed by conventional or quantitative (q) polymerase chain reaction (PCR), and Northern blot analysis (Jeck and Sharpless, 2014). RT-qPCR analysis of circular RNAs using divergent primers has been widely used for the detection, validation, and sometimes quantification of circRNAs (Abdelmohsen et al ., 2015 and 2017; Panda et al ., 2017b). As detailed here, divergent primers designed to span the circRNA backsplice junction sequence can specifically amplify the circRNAs and not the counterpart linear RNA. In sum, RT-PCR analysis using divergent primers allows direct detection and quantification of circRNAs.

  14. MINIX4RT: real-time interprocess communications facilities

    OpenAIRE

    Pessolani, Pablo Andrés

    2006-01-01

    MINIX4RT es una extensión del conocido Sistema Operativo MINIX que incorpora servicios de Tiempo Real Estricto en un nuevo microkernel pero manteniendo compatibilidad con las versiones anteriores del MINIX estándar. La Comunicación entre Procesos es un mecanismo que permite hacer extensible a un Sistema Operativo, pero debe estar libre de Inversión de Prioridades para ser utilizado en aplicaciones de Tiempo Real. Como las primitivas de MINIX no disponen de esta funcionalidad, se incorporar...

  15. Applications of LANCE Data at SPoRT

    Science.gov (United States)

    Molthan, Andrew

    2014-01-01

    Short term Prediction Research and Transition (SPoRT) Center: Mission: Apply NASA and NOAA measurement systems and unique Earth science research to improve the accuracy of short term weather prediction at the regional/local scale. Goals: Evaluate and assess the utility of NASA and NOAA Earth science data and products and unique research capabilities to address operational weather forecast problems; Provide an environment which enables the development and testing of new capabilities to improve short term weather forecasts on a regional scale; Help ensure successful transition of new capabilities to operational weather entities for the benefit of society

  16. SMAP Data Assimilation at NASA SPoRT

    Science.gov (United States)

    Blankenship, Clay B.; Case, Jonathan L.; Zavodsky, Bradley T.

    2016-01-01

    The NASA Short-Term Prediction Research and Transition (SPoRT) Center maintains a near-real- time run of the Noah Land Surface Model within the Land Information System (LIS) at 3-km resolution. Soil moisture products from this model are used by several NOAA/National Weather Service Weather Forecast Offices for flood and drought situational awareness. We have implemented assimilation of soil moisture retrievals from the Soil Moisture Ocean Salinity (SMOS) and Soil Moisture Active/ Passive (SMAP) satellites, and are now evaluating the SMAP assimilation. The SMAP-enhanced LIS product is planned for public release by October 2016.

  17. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  18. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  19. Characteristics of floc formation of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of floc formation. The physical, chemical and electrochemical properties of powdered ion exchange resin were measured and the factors related to floc formation of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index. It was found that these factors were mixing ratio, nature of resins and particle size of resins. In addition, it was assumed on the bases of these results that the amount of resin floc was related to sum of the surface electric charges of both resins. The filling ratio of resin floc was related to their product by multiplication and an experimental expression was obtained. The specific settle volume of resin floc could then be simulated by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  20. Characteristics of floc formation of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of floc formation. The physical, chemical and electrochemical properties of powdered ion exchange resin were measured and the factors related to floc formation of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index. It was found that these factors were mixing ratio, nature of resins and particle size of resins. In addition, it was assumed on the bases of these results that the amount of resin floc was related to sum of the surface electric charges of both resins. The filling ratio of resin floc was related to their product by multiplication and an experimental expression was obtained. The specific settle volume of resin floc could then be simulated by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  1. Nanomechanical properties of dental resin-composites.

    Science.gov (United States)

    El-Safty, S; Akhtar, R; Silikas, N; Watts, D C

    2012-12-01

    To determine by nanoindentation the hardness and elastic modulus of resin-composites, including a series with systematically varied filler loading, plus other representative materials that fall into the categories of flowable, bulk-fill and conventional nano-hybrid types. Ten dental resin-composites: three flowable, three bulk-fill and four conventional were investigated using nanoindentation. Disc specimens (15mm×2mm) were prepared from each material using a metallic mold. Specimens were irradiated in the mold at top and bottom surfaces in multiple overlapping points (40s each) with light curing unit at 650mW/cm(2). Specimens were then mounted in 3cm diameter phenolic ring forms and embedded in a self-curing polystyrene resin. After grinding and polishing, specimens were stored in distilled water at 37°C for 7 days. Specimens were investigated using an Agilent Technologies XP nanoindenter equipped with a Berkovich diamond tip (100nm radius). Each specimen was loaded at one loading rate and three different unloading rates (at room temperature) with thirty indentations, per unloading rate. The maximum load applied by the nanoindenter to examine the specimens was 10mN. Dependent on the type of the resin-composite material, the mean values ranged from 0.73GPa to 1.60GPa for nanohardness and from 14.44GPa to 24.07GPa for elastic modulus. There was a significant positive non-linear correlation between elastic modulus and nanohardness (r(2)=0.88). Nonlinear regression revealed a significant positive correlation (r(2)=0.62) between elastic moduli and filler loading and a non-significant correlation (r(2)=0.50) between nanohardness and filler loading of the studied materials. Varying the unloading rates showed no consistent effect on the elastic modulus and nanohardness of the studied materials. For a specific resin matrix, both elastic moduli and nanohardness correlated positively with filler loading. For the resin-composites investigated, the group-average elastic

  2. Study on the pyrolysis of phenol-formaldehyde (PF) resin and modified PF resin

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jigang, E-mail: wangjigang@seu.edu.cn [Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Jiang, Haiyun [Jiangsu Key Laboratory of Advanced Metallic Materials, School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); School of Materials Science and Engineering, Southeast University, Nanjing Institute of Technology, Nanjing 210013 (China); Jiang, Nan [Institute of Theoretical and Computational Chemistry, Nanjing University, Nanjing 210093 (China)

    2009-12-10

    The pyrolysis of pure phenol-formaldehyde (PF) resin and boron carbide (B{sub 4}C) modified PF resin was investigated by using thermogravimetry (TG) and pyrolysis gas-chromatography-mass-spectrometry (PY-GC/MS). Scanning electron microscope (SEM) and Fourier transform infrared (FT-IR) spectroscopy were also employed to investigate the micro-structural evolution. It was shown from the TG analysis that the char residues of pure PF resin were 62.9 and 60.5% after being pyrolyzed at 700 and 1000 {sup o}C, respectively. The degradation and failure of the resin matrix were mainly resulted from the release of volatiles. The phenol and its methyl derivates took a large proportion in the amount of volatiles. In comparison with the pure PF resin, the char residues of B{sub 4}C modified PF resin were obviously higher, with the values of 71.9 and 68.4% at 700 and 1000 {sup o}C, respectively. Due to the oxidation-reduction reactions between B{sub 4}C additive and oxygen-containing volatiles including CO and H{sub 2}O, partial carbon and oxygen elements in the volatiles remained in the resin matrix in the forms of amorphous carbon and B{sub 2}O{sub 3}, respectively. The results of SEM and FT-IR characterization demonstrated the occurrence of the modification, and the amorphous carbon existed in the form of reticular substance. In addition, the amount of the released phenol and its methyl derivates was also decreased drastically due to the formation of borate.

  3. Effect of Resin Coating and Chlorhexidine on Microleakage of Two Resin Cements after Storage

    Directory of Open Access Journals (Sweden)

    F. Shafie

    2010-03-01

    Full Text Available Objective: Evaluating the effect of resin coating and chlorhexidine on microleakage of two resin cements after water storage.Materials and Methods: Standardized class V cavities were prepared on facial and lingual surfaces of one hundred twenty intact human molars with gingival margins placed 1mm below the cemento-enamel junction. Indirect composite inlays were fabricated and thespecimens were randomly assigned into 6 groups. In Groups 1 to 4, inlays were cemented with Panavia F2.0 cement. G1: according to the manufacturer’s instruction. G2: with light cured resin on the ED primer. G3: chlorhexidine application before priming. G4: withchlorhexidine application before priming and light cured resin on primer. G5: inlays were cemented with Nexus 2 resin cement. G6: chlorhexidine application after etching. Each group was divided into two subgroups based on the 24-hour and 6-month water storagetime. After preparation for microleakage test, the teeth were sectioned and evaluated at both margins under a 20×stereomicroscope. Dye penetration was scored using 0-3 criteria.The data was analyzed using Kruskal-Wallis and complementary Dunn tests.Results: There was significantly less leakage in G2 and G4 than the Panavia F2.0 control group at gingival margins after 6 months (P<0.05. There was no significant differences in leakage between G1 and G3 at both margins after 24 hours and 6 months storage. After 6months, G6 revealed significantly less leakage than G5 at gingival margins (P=0.033. In general, gingival margins showed more leakage than occlusal margins.Conclusion: Additionally, resin coating in self-etch (Panavia F2.0 and chlorhexidine application in etch-rinse (Nexus resin cement reduced microleakage at gingival margins after storage.

  4. Post-irradiation hardness of resin-modified glass ionomer cements and a polyacid-modified composite resin

    International Nuclear Information System (INIS)

    Yap, A.U.J.

    1997-01-01

    This study examined the post-irradiation hardness of resin-modified glass ionomer cements and a polyacid-modified composite resin using a digital microhardness tester. Change in hardness of these materials over a period of 6 months was compared to that of conventional glass ionomer cements and a composite resin. With the exception of the composite resin, all materials showed a significant increase in hardness over 24 h after their initial set. Dual-cure resin-modified glass ionomer cements showed decreased hardness with increased storage time in saline at 37 o C. Results suggest that the addition of resins to glass ionomer cements does not improve initial hardness and does not negate the acid-base reaction of conventional cements. Resin addition may, however, lead to increased water sorption and decreased hardness. (author)

  5. Determination of acid–base properties of HCl acid activated palygorskite by Potentiometrie titration

    OpenAIRE

    N. FriniSrasra; E.Srasra

    2008-01-01

    The surface acidity of raw and acid activated palygorskite clay were studied by acid-base potentiometric titration. The Gran plot method was applied for the hydroxide titration and the total surface site (Hs) and the average number of protons reacted per surface site (Z) of palygorskite samples at a given ionic strength were calculated. Acid treatment increases the clay acidity and modifies its surface charge. The point of zero charge value, determined by the common crossing point of Z vs pH ...

  6. Complexometric consequent titration of bismuth-titanium mixtures in the μg-region

    International Nuclear Information System (INIS)

    Schaefer, H.

    1975-01-01

    A quantitative method is described for the determination of microquantities of bismuth and titanium. Both metals are determined complexometrically with EDTA and potentiometric equivalence point indication using a Cu-ion sensitive electrode in a consequent titration. The analysis is conducted as back-titration with standard Cu-solution. The relative error of the determination is 0.8% for bismuth (50-100 μg) and for titanium (10-30 μg) at 1.0%. Under the chosen conditions, it is possible to determine as little as 15 μg bismuth and 5 μg titanium by means of this procedure. (author)

  7. Comparison of Titration ICP and XRF Spectrometry Methods in Determination of Cerium in Lens Polishing Powder

    International Nuclear Information System (INIS)

    Ninlaphruk, Sumalee; Pichestapong, Pipat; Mungpayabal, Harinate; Jiyavaranant, Thitima; Srisukho, Supapan; Chaisai, Prapassurn

    2004-10-01

    Three analytical methods in determination of cerium in cerium oxide separated from monazite ore for producing lens polishing powder were compared. These methods are titration ICP and XRF spectrometry techniques. The cerium oxide sample with estimated 45% cerium content needed to be digested and converted into solution before the analysis. The analytical results shown significantly no difference between each method. However, the titration method was found to be more convenient and suitable for quality control in the production of cerium oxide as it does not require standard cerium and the complicated analytical instruments

  8. Selective two-step titration of thorium by sulfate displacement of the diethylenetriaminepentaacetic acid complex

    International Nuclear Information System (INIS)

    Kiefer, P.

    1980-07-01

    Thorium and other metals are complexed with excess diethylenetriaminepentaacetic acid (DTPA) at pH 1.4, the excess DTPA is titrated with Bi(III) to a xylenol orange end point, sulfate is added to complex Th(IV), and the displaced DTPA again is titrated with Bi(III). Of 61 metal ions and nonmetal anions tested, only Ga(III), Sc(III), tungstate, citrate, oxalate, and thiosulfate interfere seriously. Lesser interferences are In(III), Zr(IV), V(IV), and permanganate. The standard deviation is 2 μg for 56 to 840 μg Th

  9. Determination of uranyl ion by potentiometric titration using an uranyl-selective electrode

    International Nuclear Information System (INIS)

    Nassory, N.S.

    1990-01-01

    A potentiometric titration of uranyl ion is described using an uranyl selective electrode based on a membrane containing a complex of UO 2 -bis[di-4-(1,1,3,3-tetramethylbutyl)phenyl phosphate] as an ion-exchanger and tritolyl phosphate as a solvent mediator. The titrations were carried out with various titrants: Sodium hydroxide, potassium fluoride and sodium salts of acetate, oxalate and citrate. The equivalence points were determined by Gran's method. Good results were obtained by using sodium oxalate as a titrant for the determination of uranium in several samples of ammonium diuranate. The results were quite comparable with those obtained by X-ray fluorescence spectrometry. (orig.)

  10. Determination of sulfur compounds in hydrotreated transformer base oil by potentiometric titration.

    Science.gov (United States)

    Chao, Qiu; Sheng, Han; Cheng, Xingguo; Ren, Tianhui

    2005-06-01

    A method was developed to analyze the distribution of sulfur compounds in model sulfur compounds by potentiometric titration, and applied to analyze hydrotreated transformer base oil. Model thioethers were oxidized to corresponding sulfoxides by tetrabutylammonium periodate and sodium metaperiodate, respectively, and the sulfoxides were titrated by perchloric acid titrant in acetic anhydride. The contents of aliphatic thioethers and total thioethers were then determined from that of sulfoxides in solution. The method was applied to determine the organic sulfur compounds in hydrotreated transformer base oil.

  11. Higher Order Inclusion Complexes and Secondary Interactions Studied by Global Analysis of Calorimetric Titrations

    DEFF Research Database (Denmark)

    Schönbeck, Jens Christian Sidney; Holm, René; Westh, Peter

    2012-01-01

    This paper investigates the use of isothermal titration calorimetry (ITC) as a tool for studying molecular systems in which weaker secondary interactions are present in addition to a dominant primary interaction. Such systems are challenging since the signal pertaining to the stronger primary......). The results are validated by a 13C NMR titration and negative controls with a bile salt with no secondary binding site (glycocholate) (K = 2.96 ± 0.01 × 103 M–1). The method proved useful for detailed analysis of ITC data and may strengthen its use as a tool for studying molecular systems by advanced binding...

  12. Determination of fluoride ions in water by condutometric titration with lanthanum nitrates

    International Nuclear Information System (INIS)

    Alves, J.C.

    1986-01-01

    An alternative method for determining fluoride ions in drinking water by condutometric titration using La(NO 3 ) 3 as titrant is presented. The method is based on previous separation of fluoride from sample by distillation at 135 0 C. The pH of the distillated is adjusted between 5,5 - 6,0; ethanol is adicioned in 50% titrating the resultant solution with La(NO 3 ) 3 . In these conditions, fluoride ions are determined with accuracy respectively, 5% and 4%. Natural samples of drinking water were analysed by this method and by the ion selective method, with agreement among the results. (author) [pt

  13. The SPoRT concept of bracing for idiopathic scoliosis.

    Science.gov (United States)

    Zaina, Fabio; Fusco, Claudia; Atanasio, Salvatore; Negrini, Stefano

    2011-01-01

    The SPoRT (acronym: Symmetrical, Patient-oriented, Rigid, Three-dimensional, active) concept of bracing is a new way to build braces based on our 20 years of experience and the biomechanical principles of scoliosis correction, inclusive of the Sibilla and Sforzesco braces. The concept always requires a custom brace, which is made according to the patient's individual requirements. New technologies such as CAD-CAM can be applied, and often for better results, without the customary use of prebuilt forms whose measurements are stored in databases. Once the initial draft brace is completed, a final test must be made on the patient to modify and adapt it, depending on his or her real interaction between the body and the brace. The results that are today available on the SPoRT concept relate to the Sforzesco brace and are necessarily short-term, because the first treated patients are now reaching the fourth-year follow-up examination and haven't yet completed their treatments. On the basis of the initial evaluations, we can state that the Sforzesco brace is more effective than the Lyon brace after 6 months of treatment and that the Sforzesco brace is equally effective as the Risser Plast brace.

  14. Used mixed oxide fuel reprocessing at RT-1 plant

    Energy Technology Data Exchange (ETDEWEB)

    Kolupaev, D.; Logunov, M.; Mashkin, A.; Bugrov, K.; Korchenkin, K. [FSUE PA ' Mayak' , 30, Lenins str, Ozersk, 460065 (Russian Federation); Shadrin, A.; Dvoeglazov, K. [ITCP ' PRORYV' , 2/8 Malaya Krasmoselskay str, Moscow, 107140 (Russian Federation)

    2016-07-01

    Reprocessing of the mixed uranium-plutonium spent nuclear fuel of the BN-600 reactor was performed at the RT-1 plant twice, in 2012 and 2014. In total, 8 fuel assemblies with a burn-up from 73 to 89 GW day/t and the cooling time from 17 to 21 years were reprocessed. The reprocessing included the stages of dissolution, clarification, extraction separation of U and Pu with purification from the fission products, refining of uranium and plutonium at the relevant refining cycles. Dissolution of the fuel composition of MOX used nuclear fuel (UNF) in nitric acid solutions in the presence of fluoride ion has occurred with the full transfer of actinides into solution. Due to the high content of Pu extraction separation of U and Pu was carried out on a nuclear-safe equipment designed for the reprocessing of highly enriched U spent nuclear fuel and Pu refining. Technological processes of extraction, separation and refining of actinides proceeded without deviations from the normal mode. The output flow of the extraction outlets in their compositions corresponded to the regulatory norms and remained at the level of the compositions of the streams resulting from the reprocessing of fuel types typical for the RT-1 plant. No increased losses of Pu into waste have been registered during the reprocessing of BN-600 MOX UNF an compare with VVER-440 uranium UNF reprocessing. (authors)

  15. Request for regular monitoring of the symbiotic variable RT Cru

    Science.gov (United States)

    Waagen, Elizabeth O.

    2014-08-01

    Dr. Margarita Karovska (Harvard-Smithsonian Center for Astrophysics) and colleagues have requested AAVSO observer assistance in their campaign on the symbiotic variable RT Cru (member of a new class of hard X-ray emitting symbiotic binaries). Weekly or more frequent monitoring (B, V, and visual) beginning now is requested in support of upcoming Chandra observations still to be scheduled. "We plan Chandra observations of RT Cru in the near future that will help us understand the characteristics of the accretion onto the white dwarf in this sub-class of symbiotics. This is an important step for determining the precursor conditions for formation of a fraction of asymmetric Planetary Nebulae, and the potential of symbiotic systems as progenitors of at least a fraction of Type Ia supernovae." Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.

  16. Treatment of spent ion-exchange resins

    International Nuclear Information System (INIS)

    Ghattas, N.K.; Ikladious, N.E.; Eskander, S.B.

    1981-01-01

    PMMA was studied with the aim to evaluate its usefulness as an incorporation medium for the final containment of spent ion-exchange resins. The study of the effect of water content (ranging from 25 to 100%) of the incorporated resin into PMMA on the compression strength of the final solid products shows that with the increasing water content the compression strength of the final products decreases sharply. Hardness of the final products follows nearly the same trend of compression strength. Increasing gamma irradiation doses, up to 7.77x10 7 rad, PMMA shows increase in compression strength and hardness for small doses and then decreases with increasing irradiation dose due to the increase in polymerization process and the degradation of the incorporation medium

  17. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  18. Lysine purification with cation exchange resin

    International Nuclear Information System (INIS)

    Khayati, GH.; Mottaghi Talab, M.; Hamooni Hagheeghat, M.; Fatemi, M.

    2003-01-01

    L-lysine is an essential amino acid for the growth most of animal species and the number one limiting amino acid for poultry. After production and biomass removal by filtration and centrifugation, the essential next step is the lysine purification and recovery. There are different methods for lysine purification. The ion exchange process is one of the most commonly used purification methods. Lysine recovery was done from broth by ion exchange resin in three different ways: repeated passing, resin soaking and the usual method. Impurities were isolated from the column by repeated wash with distilled water. Recovery and purification was done with NH 4 OH and different alcohol volumes respectively. The results showed that repeated passing is the best method for lysine absorption (maximum range 86.21 %). Washing with alkali solution revealed that most of lysine is obtained in the first step of washing. The highest degree of lysine purification was achieved with the use of 4 volumes of alcohol

  19. The SimpleMix study with biphasic insulin aspart 30: a randomized controlled trial investigating patient-driven titration versus investigator-driven titration.

    Science.gov (United States)

    Gao, Yan; Luquez, Cecilia; Lynggaard, Helle; Andersen, Henning; Saboo, Banshi

    2014-12-01

    The study aimed to confirm the efficacy, through non-inferiority, of patient-driven versus investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) in terms of glycemic control assessed by HbA1c change. SimpleMix was a 20 week, open-label, randomized, two-armed, parallel-group, multicenter study in five countries (Argentina, China, India, Poland, and the UK). Patients with type 2 diabetes were randomized into either patient-driven or investigator-driven BIAsp 30 titration groups. Non-inferiority of patient-driven vs. investigator-driven titration based on change in HbA1c from baseline to week 20 could not be demonstrated. Mean (SE) estimated change from baseline to week 20 was -0.72 (0.08)% in the patient-driven group and -0.97 (0.08)% in the investigator-driven group; estimated difference 0.25% (95% CI: 0.04; 0.46). Estimated mean change (SE) in fasting plasma glucose from baseline to week 20 was similar between groups: -0.94 (0.21) mmol/L for patient-driven and -1.07 (0.22) mmol/L for investigator-driven (difference non-significant). Both treatment arms were well tolerated, and hypoglycemic episode rates were similar between groups, with a rate ratio of 0.77 (95% CI: 0.54; 1.09; p = 0.143) for all hypoglycemic episodes and 0.78 (95% CI: 0.42; 1.43; p = 0.417) for nocturnal hypoglycemic episodes. Non-inferiority of patient-driven versus investigator-driven titration with regard to change from baseline to end-of-treatment HbA1c could not be confirmed. It is possible that a clinic visit 12 weeks after intensification of treatment with BIAsp 30 in patients with type 2 diabetes inadequately treated with basal insulin may benefit patient-driven titration of BIAsp 30. A limitation of the study was the relatively small number of patients recruited in each country, which does not allow country-specific analyses to be performed. Overall, treatment with BIAsp 30 was well tolerated in both treatment groups.

  20. Measuring titratable alkalinity by single versus double endpoint titration: An evaluation in two cyprinodont species and implications for characterizing net H+ flux in aquatic organisms.

    Science.gov (United States)

    Brix, Kevin V; Wood, Chris M; Grosell, Martin

    2013-01-01

    In this study, Na(+) uptake and acid-base balance in the euryhaline pupfish Cyprinodon variegatus variegatus were characterized when fish were exposed to pH 4.5 freshwater (7mM Na(+)). Similar to the related cyprinodont, Fundulus heteroclitus, Na(+) uptake was significantly inhibited when exposed to low pH water. However, it initially appeared that C. v. variegatus increased apparent net acid excretion at low pH relative to circumneutral pH. This result is opposite to previous observations for F. heteroclitus under similar conditions where fish were observed to switch from apparent net H(+) excretion at circumneutral pH to apparent net H(+) uptake at low pH. Further investigation revealed disparate observations between these studies were the result of using double endpoint titrations to measure titratable alkalinity fluxes in the current study, while the earlier study utilized single endpoint titrations to measure these fluxes (i.e.,. Cyprinodon acid-base transport is qualitatively similar to Fundulus when characterized using single endpoint titrations). This led to a comparative investigation of these two methods. We hypothesized that either the single endpoint methodology was being influenced by a change in the buffer capacity of the water (e.g., mucus being released by the fish) at low pH, or the double endpoint methodology was not properly accounting for ammonia flux by the fish. A series of follow-up experiments indicated that buffer capacity of the water did not change significantly, that excretion of protein (a surrogate for mucus) was actually reduced at low pH, and that the double endpoint methodology does not properly account for NH(3) excretion by fish under low pH conditions. As a result, it overestimates net H(+) excretion during low pH exposure. After applying the maximum possible correction for this error (i.e., assuming that all ammonia is excreted as NH(3)), the double endpoint methodology indicates that net H(+) transport was reduced to