WorldWideScience

Sample records for resin flow monitoring

  1. Flow monitoring of microwave pre-heated resin in LCM processes

    Science.gov (United States)

    Rubino, F.; Paradiso, V.; Carlone, P.

    2017-10-01

    Liquid composite molding is manufacturing techniques that involve the injection or infusion of catalyzed liquid resin into a mold to impregnate a dry fiber preform. The challenges of LCM processes are related to the obtaining of a complete wetting of the reinforcement as well as a reduction of the void to obtain a final product with high mechanical properties. The heating of the resin prior the injection into the mold cavity has proven to be useful to improve the LCM processes. The increasing of temperature results in a reduction of resin viscosity and allows the resin to flow more easily through the reinforcement; the cure stage is also improved resulting in a reduction of global process time required. Besides the conventional solutions to heat up the resin based on the thermal conduction, in-line microwave heating is a suitable method to heat dielectric materials providing an even temperature distribution through the resin, thereby avoiding a thermal gradient between the surface and the core of liquid resin, which could result in a premature and uncontrolled cure. In the present work, an in-line microwave system, manually controlled, have been coupled with a VARTM apparatus to heat the resin before the infusion. In addition, parallel-plate dielectric sensors and pressure sensors, embedded into the mold, were employed to track the flow front through the fiber reinforcement in two distinct cases: unheated resin and pre-heated resin. The aim of work was to assess the effectiveness of microwave pre-heating to improve the macro and micro-impregnation of dry preform. The obtained results showed capability of in-line microwave heating to shorten the impregnation of dry fabric and provide a homogeneous wetting of fibers.

  2. Resin Flow Analysis in the Injection Cycle of a Resin Transfer Molded Radome

    Science.gov (United States)

    Golestanian, Hossein; Poursina, Mehrdad

    2007-04-01

    Resin flow analysis in the injection cycle of an RTM process was investigated. Fiberglass and carbon fiber mats were used as reinforcements with EPON 826 epoxy resin. Numerical models were developed in ANSYS finite element software to simulate resin flow behavior into a mold of conical shape. Resin flow into the woven fiber mats is modeled as flow through porous media. The injection time for fiberglass/epoxy composite is found to be 4407 seconds. Required injection time for the carbon/epoxy composite is 27022 seconds. Higher injection time for carbon/epoxy part is due to lower permeability value of the carbon fibers compared to glass fiber mat.

  3. Monitoring in situ in real time of resin infusion for thermoset composite structures

    Science.gov (United States)

    Faci, A.; Wang, P.; Cochrane, C.; Koncar, V.

    2017-10-01

    The presented work investigates changes in electrical resistance of embedded sensory yarns as a method to monitor the resin flow front position and curing degree of resin during manufacturing of composite structures by vacuum infusion technology. The sensor concept is based on Piezo-resistive sensors integrated to the flax fabric, having almost identical propriety and dimensions as the flax threads used for the production of reinforcements. In the first time sensors have been characterized and first measures of the resin infusion have been realized in order to demonstrate the feasibility of the proposed approach. Then, the measures in real time were realized with fibrous sensors added to the flax fabric (green composites) to monitor the flow front of resin. A large amount of data recorded, filtered, examined, analysed and processed in order to understand and to optimize the infusion and polymerization process.

  4. Optical Fibre Grating Refractometers for Resin Cure Monitoring.

    OpenAIRE

    Buggy, Stephen J.; Chehura, Edmon; James, Stephen W.; Tatam, Ralph P.

    2007-01-01

    The use of fibre grating refractometers as a means of monitoring the cure of a UVcured epoxy resin is presented. The wavelength shift of the attenuation bands of a long period grating and the spectral response of a tilted fibre Bragg grating sensor were measured simultaneously during the cure of the resin and compared with measurements made using a fibre optic Fresnel based refractometer. The results showed a good correlation (6 x 10 -3 rius) and illustrate the potential of ...

  5. Resin flow/fiber deformation model for composites

    International Nuclear Information System (INIS)

    Gutowski, T.G.

    1985-01-01

    This paper presents a resin flow/fiber deformation model that can be used to predict the behavior of composites during the molding cycle. The model can take into account time varying pressure and viscosity and output the time history of the fiber volume fraction. With this known, the composite thickness, resin pressure, and fiber pressure can all be determined as a function of time. The results of this model are in good agreement with experimentally measured values. 10 references, 9 figures

  6. Resin Flow in Fiber Preformed by Vacuum Assisted Resin Transfer Molding with Flexible Tools

    Directory of Open Access Journals (Sweden)

    M.M. Shokrieh

    2008-12-01

    Full Text Available Vacuum assisted resin transfer molding, as a sub-branch of RTM is a method of manufacturing composite specimens. Considering the industrial development of this method, different modified techniques are designed to improve its performance. Among these techniques, using a half flexible mold is regarded as an important method. In this work, dominant equations of resin flow through the mold in polar coordinates are solved analytically. Based on this approach, closed-form solutions have been presented for different parameters such as thickness variation of preformed fiber, resin pressure, resin velocity and fiber volume fraction as functions of two variables, namely, time and the distance from injection port. After verification of the approach employed in this work, the results are presented. Important parameters influencing the quality and the rate production are studied in detail.

  7. Monitoring the Cure State of Thermosetting Resins by Ultrasound

    Science.gov (United States)

    Lionetto, Francesca; Maffezzoli, Alfonso

    2013-01-01

    The propagation of low intensity ultrasound in a curing resin, acting as a high frequency oscillatory excitation, has been recently proposed as an ultrasonic dynamic mechanical analysis (UDMA) for cure monitoring. The technique measures sound velocity and attenuation, which are very sensitive to changes in the viscoelastic characteristics of the curing resin, since the velocity is related to the resin storage modulus and density, while the attenuation is related to the energy dissipation and scattering in the curing resin. The paper reviews the results obtained by the authors’ research group in the last decade by means of in-house made ultrasonic set-ups for both contact and air-coupled ultrasonic experiments. The basics of the ultrasonic wave propagation in polymers and examples of measurements of the time-evolution of ultrasonic longitudinal modulus and chemical conversion of different thermosetting resins are presented. The effect of temperature on the cure kinetics, the comparison with rheological, low frequency dynamic mechanical and calorimetric results, and the correlation between ultrasonic modulus and crosslinking density will be also discussed. The paper highlights the reliability of ultrasonic wave propagation for monitoring the physical changes taking place during curing and the potential for online monitoring during polymer and polymer matrix composite processing. PMID:28788306

  8. Monitoring the Cure State of Thermosetting Resins by Ultrasound

    Directory of Open Access Journals (Sweden)

    Alfonso Maffezzoli

    2013-09-01

    Full Text Available The propagation of low intensity ultrasound in a curing resin, acting as a high frequency oscillatory excitation, has been recently proposed as an ultrasonic dynamic mechanical analysis (UDMA for cure monitoring. The technique measures sound velocity and attenuation, which are very sensitive to changes in the viscoelastic characteristics of the curing resin, since the velocity is related to the resin storage modulus and density, while the attenuation is related to the energy dissipation and scattering in the curing resin. The paper reviews the results obtained by the authors’ research group in the last decade by means of in-house made ultrasonic set-ups for both contact and air-coupled ultrasonic experiments. The basics of the ultrasonic wave propagation in polymers and examples of measurements of the time-evolution of ultrasonic longitudinal modulus and chemical conversion of different thermosetting resins are presented. The effect of temperature on the cure kinetics, the comparison with rheological, low frequency dynamic mechanical and calorimetric results, and the correlation between ultrasonic modulus and crosslinking density will be also discussed. The paper highlights the reliability of ultrasonic wave propagation for monitoring the physical changes taking place during curing and the potential for online monitoring during polymer and polymer matrix composite processing.

  9. Serial Network Flow Monitor

    Science.gov (United States)

    Robinson, Julie A.; Tate-Brown, Judy M.

    2009-01-01

    Using a commercial software CD and minimal up-mass, SNFM monitors the Payload local area network (LAN) to analyze and troubleshoot LAN data traffic. Validating LAN traffic models may allow for faster and more reliable computer networks to sustain systems and science on future space missions. Research Summary: This experiment studies the function of the computer network onboard the ISS. On-orbit packet statistics are captured and used to validate ground based medium rate data link models and enhance the way that the local area network (LAN) is monitored. This information will allow monitoring and improvement in the data transfer capabilities of on-orbit computer networks. The Serial Network Flow Monitor (SNFM) experiment attempts to characterize the network equivalent of traffic jams on board ISS. The SNFM team is able to specifically target historical problem areas including the SAMS (Space Acceleration Measurement System) communication issues, data transmissions from the ISS to the ground teams, and multiple users on the network at the same time. By looking at how various users interact with each other on the network, conflicts can be identified and work can begin on solutions. SNFM is comprised of a commercial off the shelf software package that monitors packet traffic through the payload Ethernet LANs (local area networks) on board ISS.

  10. Structural health monitoring using fiber optic distributed sensors for vacuum-assisted resin transfer molding

    Science.gov (United States)

    Eum, S. H.; Kageyama, K.; Murayama, H.; Uzawa, K.; Ohsawa, I.; Kanai, M.; Kobayashi, S.; Igawa, H.; Shirai, T.

    2007-12-01

    In this study we implemented manufacturing process and strain monitoring of a composite structure by optical fiber sensors for vacuum-assisted resin transfer molding (VaRTM). Optical fibers with fiber Bragg gratings were embedded into a glass fiber reinforced plastic specimen made by VaRTM and the applicability of structural health monitoring with fiber Bragg grating (FBG) sensors based on optical frequency domain reflectometry (OFDR) was investigated. In this study, long-gage FBGs which are 10 times longer than ordinary FBGs (which are about 10 mm long) were employed for distributed sensing. We can easily map the strain or temperature profile along gratings by OFDR and the spatial resolution of this sensing technique is about 1 mm. The resin flow process in VaRTM could be monitored by measuring the difference in temperature between the resin and preform. Then, the shrinkage of resin could be also monitored during the curing process. The specimen was then subjected to a bending load in a three-point bending test and the strain distributions along the FBGs were measured. From these results we could show the applicability of distributed sensors to quality assurance of a composite structure made by VaRTM and assessment of the structural integrity of in-service composite structures.

  11. Photothermal radiometry monitoring of light curing in resins

    Science.gov (United States)

    Zambrano-Arjona, M. A.; Medina-Esquivel, R.; Alvarado-Gil, J. J.

    2007-10-01

    Real time measurement of thermal diffusivity during the evolution of the light curing process in dental resins is reported using photothermal radiometry. The curing is induced by a non-modulated blue light beam, and at the same time, a modulated red laser beam is sent onto the sample, generating a train of thermal waves that produce modulated infrared radiation. The monitoring of this radiation permits to follow the time evolution of the process. The methodology is applied to two different commercially available light curing resin-based composites. In all cases thermal diffusivity follows a first order kinetics with similar stabilization characteristic times. Analysis of this kinetics permits to exhibit the close relationship of increase in thermal diffusivity with the decrease in monomer concentration and extension of the polymerization in the resin, induced by the curing light. It is also shown that the configuration in which the resin is illuminated by the modulated laser can be the basis for the development of an in situ technique for the determination of the degree of curing.

  12. Ethernet Flow Monitoring with IPFIX

    NARCIS (Netherlands)

    Hofstede, R.J.; Drago, Idilio; Sperotto, Anna; Pras, Aiko

    The increasing amount of network traffic and the huge bandwidth needed to carry it requires managers to use scalable solutions to monitor their networks. Nowadays, flow-based techniques, such as Cisco’s NetFlow, provide aggregated network data and an overview of network activity at the IP layer.

  13. Monitoring probe for groundwater flow

    Science.gov (United States)

    Looney, B.B.; Ballard, S.

    1994-08-23

    A monitoring probe for detecting groundwater migration is disclosed. The monitor features a cylinder made of a permeable membrane carrying an array of electrical conductivity sensors on its outer surface. The cylinder is filled with a fluid that has a conductivity different than the groundwater. The probe is placed in the ground at an area of interest to be monitored. The fluid, typically saltwater, diffuses through the permeable membrane into the groundwater. The flow of groundwater passing around the permeable membrane walls of the cylinder carries the conductive fluid in the same general direction and distorts the conductivity field measured by the sensors. The degree of distortion from top to bottom and around the probe is precisely related to the vertical and horizontal flow rates, respectively. The electrical conductivities measured by the sensors about the outer surface of the probe are analyzed to determine the rate and direction of the groundwater flow. 4 figs.

  14. Tracer-monitored flow titrations.

    Science.gov (United States)

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A novel calorimetry technique for monitoring electron beam curing of polymer resins

    International Nuclear Information System (INIS)

    Chen, J.H.; Johnston, A.; Petrescue, L.; Hojjati, M.

    2006-01-01

    This paper describes the development of a calorimetry-based technique for monitoring of the curing of electron beam (EB) curable resins, including design of the calorimeter hardware and the development of an analytical model for calculating resin cure rates and radiation dose. Factors affecting the performance of the calorimeter were investigated. Experimental trials monitoring the curing of epoxy resin were conducted under single pass and multiple passes of EB irradiation. Results show that the developed calorimeter is a simple, inexpensive and reasonably accurate technique for monitoring the EB curing of cationic epoxies

  16. Resin flow responses to fertilization, wounding and fungal inoculation in loblolly pine (Pinus taeda) in North Carolina.

    Science.gov (United States)

    Knebel, Larissa; Robison, Daniel J; Wentworth, Thomas R; Klepzig, Kier D

    2008-06-01

    Resin flow is the primary means of natural defense against southern pine beetle (Dendroctonus frontalis Zimm.), the most important insect pest of Pinus spp. in the southern United States. As a result, factors affecting resin flow are of interest to researchers and forest managers. We examined the influence of fertilization, artificial wounding and fungal inoculation on resin flow in 6- and 12-year-old stands of loblolly pine (Pinus taeda L.) and determined the extent of that influence within and above the wounded stem area and through time. Fertilization increased constitutive resin flow, but only the younger trees sustained increased resin flow after wounding and inoculation treatments. An induced resin flow response occurred between 1 and 30 days after wounding and inoculation treatments. Wounding with inoculation resulted in greater resin flow than wounding alone, but increasing amounts of inoculum did not increase resin flow. Increased resin flow (relative to controls) lasted for at least 90 days after wounding and inoculation. This increase appeared to be limited to the area of treatment, at least in younger trees. The long-lasting effects of fungal inoculation on resin flow, as well as the response to fertilization, suggest that acquired resistance through induced resin flow aids in decreasing susceptibility of loblolly pine to southern pine beetle.

  17. Infrared spectroscopic monitoring of urea addition to oriented strandboard resins

    Science.gov (United States)

    Chi-Leung So; Thomas L. Eberhardt; Ernest Hsu; Brian K. Via; Chung Y. Hse

    2007-01-01

    One of the variables in phenol formaldehyde adhesive resin formulation is the addition of urea, which allows the resin manufacturer to manipulate both product functionality and cost. Nitrogen content can be used as a measure of the level of urea addition because most of the nitrogen present is derived from urea added at the end of the preparation process. Nitrogen...

  18. Cure monitoring of epoxy resin by using fiber bragg grating sensor

    International Nuclear Information System (INIS)

    Lee, Jin Hyuk; Kim, Dae Hyun

    2016-01-01

    In several industrial fields, epoxy resin is widely used as an adhesive for co-curing and manufacturing various structures. Controlling the manufacturing process is required for ensuring robust bonding performance and the stability of the structures. A fiber optic sensor is suitable for the cure monitoring of epoxy resin owing to the thready shape of the sensor. In this paper, a fiber Bragg grating (FBG) sensor was applied for the cure monitoring of epoxy resin. Based on the experimental results, it was demonstrated that the FBG sensor can monitor the status of epoxy resin curing by measuring the strain caused by volume shrinkage and considering the compensation of temperature. In addition, two types of epoxy resin were used for the cure-monitoring; moreover, when compared to each other, it was found that the two types of epoxy had different cure-processes in terms of the change of strain during the curing. Therefore, the study proved that the FBG sensor is very profitable for the cure-monitoring of epoxy resin

  19. Flow Characteristics of a Thermoset Fiber Composite Photopolymer Resin in a Vat Polymerization Additive Manufacturing Process

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Spangenberg, Jon; Pedersen, David B.

    understood. Research indicates an orientation within the manufacturing layer and efforts have been made to achieve a more uniform orientation within the part. A vat polymerization machine consisting of a resin vat and a moving build plate has been simulated using the fluid flow module of Comsol Multiphysics...... photopolymer resin. The prediction can be used to identify potential clusters or misalignment of fibers and in the future allow for optimization of the machine design and manufacturing process....

  20. Apparatus for monitoring two-phase flow

    Science.gov (United States)

    Sheppard, John D.; Tong, Long S.

    1977-03-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  1. Apparatus for monitoring two-phase flow

    International Nuclear Information System (INIS)

    Sheppard, J.D.; Tong, L.S.

    1977-01-01

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods. 3 claims, 9 figures

  2. Optimising the flow pipe arrangement of resin infusion under flexible tooling

    NARCIS (Netherlands)

    Kessels, Josef F.A.; Kessels, J.F.A.; Jonker, Attie S.; Akkerman, Remko

    2007-01-01

    A method is presented to optimise the flow pipe arrangement for the RIFT process for complex 2 1/2D geometries. To this end, a mesh distance-based model is coupled to a genetic optimisation algorithm. The mesh distance-based model is based on the assumption that the resin fills the nodes closest to

  3. Push-Out Bond Strength of Restorations with Bulk-Fill, Flow, and Conventional Resin Composites

    Directory of Open Access Journals (Sweden)

    Rodrigo Vieira Caixeta

    2015-01-01

    Full Text Available The aim of this study was to evaluate the bond strengths of composite restorations made with different filler amounts and resin composites that were photoactivated using a light-emitting diode (LED. Thirty bovine incisors were selected, and a conical cavity was prepared in the facial surface of each tooth. All preparations were etched with Scotchbond Etching Gel, the Adper Scotchbond Multipurpose Plus adhesive system was applied followed by photoactivation, and the cavities were filled with a single increment of Filtek Z350 XT, Filtek Z350 XT Flow, or bulk-fill X-tra fil resin composite (n = 10 followed by photoactivation. A push-out test to determine bond strength was conducted using a universal testing machine. Data (MPa were submitted to Student’s t-test at a 5% significance level. After the test, the fractured specimens were examined using an optical microscope under magnification (10x. Although all three composites demonstrated a high prevalence of adhesive failures, the bond strength values of the different resin composites photoactivated by LED showed that the X-tra fil resin composite had a lower bond strength than the Filtek Z350 XT and Filtek Z350 XT Flow resin composites.

  4. Improving ecological response monitoring of environmental flows.

    Science.gov (United States)

    King, Alison J; Gawne, Ben; Beesley, Leah; Koehn, John D; Nielsen, Daryl L; Price, Amina

    2015-05-01

    Environmental flows are now an important restoration technique in flow-degraded rivers, and with the increasing public scrutiny of their effectiveness and value, the importance of undertaking scientifically robust monitoring is now even more critical. Many existing environmental flow monitoring programs have poorly defined objectives, nonjustified indicator choices, weak experimental designs, poor statistical strength, and often focus on outcomes from a single event. These negative attributes make them difficult to learn from. We provide practical recommendations that aim to improve the performance, scientific robustness, and defensibility of environmental flow monitoring programs. We draw on the literature and knowledge gained from working with stakeholders and managers to design, implement, and monitor a range of environmental flow types. We recommend that (1) environmental flow monitoring programs should be implemented within an adaptive management framework; (2) objectives of environmental flow programs should be well defined, attainable, and based on an agreed conceptual understanding of the system; (3) program and intervention targets should be attainable, measurable, and inform program objectives; (4) intervention monitoring programs should improve our understanding of flow-ecological responses and related conceptual models; (5) indicator selection should be based on conceptual models, objectives, and prioritization approaches; (6) appropriate monitoring designs and statistical tools should be used to measure and determine ecological response; (7) responses should be measured within timeframes that are relevant to the indicator(s); (8) watering events should be treated as replicates of a larger experiment; (9) environmental flow outcomes should be reported using a standard suite of metadata. Incorporating these attributes into future monitoring programs should ensure their outcomes are transferable and measured with high scientific credibility.

  5. The influence of plutonium concentration and solution flow rate on the effective capacity of macroporous anion exchange resin

    International Nuclear Information System (INIS)

    Marsh, S.F.; Gallegos, T.D.

    1987-07-01

    The principal aqueous process used to recover and purify plutonium at the Los Alamos Plutonium Facility is anion exchange in nitric acid. Previous studies with gel-type anion exchange resin have shown an inverse relationship between plutonium concentration in the feed solution and the optimum flow rate for this process. Because gel-type resin has been replaced with macroporous resin at Los Alamos, the relationship between plutonium concentration and solution flow rate was reexamined with the selected Lewatit MP-500-FK resin using solutions of plutonium in nitric acid and in nitric acid with high levels of added nitrate salts. Our results with this resin differ significantly from previous data obtained with gel-type resin. Flow-rate variation from 10 to 80 liters per hour had essentially no effect on the measured quantities of plutonium sorbed by the macroporous resin. However, the effect of plutonium concentration in the feed solutions was pronounced, as feed solutions that contained the highest concentrations of plutonium also produced the highest resin loadings. The most notable effect of high concentrations of dissolved nitrate salts in these solutions was an increased resin capacity for plutonium at low flow rates. 16 refs., 7 figs., 2 tabs

  6. The effect of saturation on resin flow in injection pultrusion: a preliminary numerical study

    DEFF Research Database (Denmark)

    Spangenberg, Jon; Larsen, Martin; R. Rodríguez, Rosa

    In this study, a 2-D Darcy’s law based numerical model is developed in order to investigate the effect of saturation on the propagation of the resin in the die chamber of a pultrusion line. The numerical model is established using the finite volume method and alternating direction implicit scheme....... The implemented saturation and relative permeability curves are adopted from relationships presented in the literature. The results of the numerical model highlights the importance of accurately determining thesaturation curve when included in a numerical solver that is used to predict the resin flow in injection...... pultrusion. Further research is planned within this field in order to identify realistic saturation curves for fiber reinforcements used in resin injection pultrusion....

  7. Concentrating cesium-137 from seawater using resorcinol-formaldehyde resin for radioecological monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Egorin, Andrei; Tokar, Eduard; Tutov, Mikhail; Avramenko, Valentin [Institute of Chemistry FEBRAS, Vladivostok (Russian Federation); Far Eastern Federal Univ., Vladivostok (Russian Federation); Palamarchuk, Marina; Marinin, Dmitry [Institute of Chemistry FEBRAS, Vladivostok (Russian Federation)

    2017-04-01

    A method of preconcentrating cesium-137 from seawater using a resorcinol-formaldehyde resin, which enables one to optimize the ecological monitoring procedure, has been suggested. Studies of sorption of cesium-137 from seawater by resorcinol-formaldehyde resin have been performed, and it has been demonstrated that the cation exchanger is characterized by high selectivity with respect to cesium-137. It was found that the selectivity depended on the temperature of resin solidification and the seawater pH value. The maximal value of the cesium-137 distribution coefficient is equal to 4.1-4.5 x 10{sup 3} cm{sup 3} g{sup -1}. Under dynamic conditions, the ion-exchange resin capacity is 310-910 bed volumes depending on the seawater pH, whereas the efficiency of cesium removal exceeds 95%. The removal of more than 95% of cesium-137 has been attained using 1-3 M solutions of nitric acid: here, the eluate volume was 8-8.4 bed volumes. Application of 3 M solution of nitric acid results in resin degradation with the release of gaseous products.

  8. Monitoring And Controlling Hydroponic Flow

    Science.gov (United States)

    Dreschel, Thomas W.

    1992-01-01

    Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.

  9. Resin flow responses to fertilization, wounding and fungal inoculation in loblolly pine (Pinus taeda) in North Carolina

    Science.gov (United States)

    Larissa Knebel; Daniel J. Robinson; Thomas R. Wentworth; Kier D. Klepzig

    2009-01-01

    Resin flow is the primary means of natural defense against southern pine beetle (Dendroctonus frontalis Zimm.), the most important insect pest of Pinus spp. in the southern United States. As a result, factors affecting resin flowa are of interest to researchers and forest managers. We examined the influence of fertilization, artificial...

  10. Spectrophotometric flow injection catalytic determination of molybdenum in plant digest using ion exchange resin

    International Nuclear Information System (INIS)

    Pessenda, L.C.R.

    1987-03-01

    A spectrophotometric flow injection analytical method based on the catalytic action of molybdenum on the oxidation of iodide by hydrogen peroxide in acidic medium is proposed for the molybdenum determination in plant digests. A cation exchange resin column is incorporated into a flow injection system for removal of interferents. The following system variables were investigated and optimized: reagent concentrations, sample injection volume, mixing and reaction coil lengths, temperature, sampling time, pumping rate and concentration of eluting agents. The effects of interfering species and of the acidity of samples on the molybdenum retention by the ion exchange resin column were investigated. The proposed method is characterized by good precision (r.s.d. (2.0%), a sampling rate of about 40 samples per hour, and permits the determination of molybdenum in plant digests in the range 1.0 to 40.0 μg/l. The results compare well with those obtained by graphite furnace atomic absorption spectrometry. (author) [pt

  11. Flow injection spectrophotometric determination of low concentrations of orthosphate in natural waters employing ion exchange resin

    International Nuclear Information System (INIS)

    Pessenda, L.C.R.

    1981-01-01

    A simple and fast method for the determination of low concentrations of orthophosphate in natural waters is described. Ion exchange is incorporated into a flow injection system by usina a resin column in the sample loop of a proportion injector. Effects of sample aspiration rate, sampling time, eluting agent concentration, pumping rate of the sample carrier stream and interfaces, were investigated both using 32 PO 3- 4 or 31 PO 3- 4 with columns coupled to a gerger-muller detector and incorporated in a flow system with molybdenum blue colorinetry. (M.A.C.) [pt

  12. Self-monitoring ultrasonic gas flow meter

    International Nuclear Information System (INIS)

    Lin, Y; Hans, V

    2005-01-01

    Ultrasound is predestined for gas flow velocity measurements on account of its high sensitivity to all kinds of natural and artificial turbulences in the fluid. Vortex measurements behind a bluff body as well as cross-correlation methods have been proved good. Cross-correlation measurements of natural structures determine the most frequent velocity components in the fluid. Therefore, the measured flow velocity deviates from the real mean flow velocity because of a skewed probability density distribution of the velocity components. Vortex measurements base on the principle that the frequency of the vortices generated in the wake of a bluff body is proportional to the mean flow velocity. The measurement of the periodic vortices with cross-correlation functions leads to the direct determination of the real mean flow velocity. The combination of both measuring methods results in a self-monitoring system

  13. Effect of phenol formaldehyde resin as vulcanizing agent on flow behavior of HDPE/PB blend

    Directory of Open Access Journals (Sweden)

    Moayad N. Khalaf

    2014-07-01

    Full Text Available Thermoplastic elastomer (TPE based on High density polyethylene (HDPE/polybutadiene (HDPE/PB = 70/30 parts blends containing 1, 3, 5, 7 and 10 wt.% of dimethylol phenolic resin as a vulcanizing agent in the presence of SnCl2 as catalyst was prepared. The dimethylol phenolic resin was prepared in our laboratory. The blends were compounded in mixer-60 attached to a Haake rheochord meter-90. The rheological properties were measured at temperatures 140, 160, 180 and 200 °C. The linearity of the flow curve appeared for 5% of the vulcanizing agent. The shear stress and shear viscosity have increased upon increasing the shear rate over a range of loading levels of vulcanizing agent of 1%, 3%, 5%, 7% and 10%. This may be attributed to the increased vulcanization between polyethylene and the rubber blend. The flow behavior index of the system shows a pseudo plastic nature behavior (since n < 1. The consistency index (K increased with the increase in the phenol formaldehyde resin content and the temperature. Hence, the increase in the value of the consistency index (K of the polymer melts refers to more viscous materials prepared. The activation energy for the TPE blends fluctuated indicating that there is phase separation; where each polymer behaved separately. This study showed that HDPE/PB blends are characterized with good rheological properties, which can be recommended to be processed with the injection molding technique.

  14. Near Infrared Spectroscopy for On-line Monitoring of Alkali- Free Cloth/Phenolic Resin Prepreg During Manufacture

    Science.gov (United States)

    Jiang, Bo; Huang, Yu Dong

    2007-01-01

    A NIR method was developed for the on-line monitoring of alkali-free cloth/phenolic resin prepreg during its manufacturing process. First, the sizing content of the alkali-free cloth was analyzed, and then the resin, soluble resin and volatiles content of the prepreg was analyzed simultaneously using the FT-NIR spectrometer. Partial least square (PLS) regression was used to develop the calibration models, which for the sizing content was preprocessed by 1stDER +MSC, for the volatile content by 1stDER +VN, for the soluble resin content by 1stDER +MSC and for the resin content by the VN spectral data preprocessing method. RMSEP of the prediction model for the sizing content was 0.732 %, for the resin content it was 0.605, for the soluble resin content it was 0.101 and for volatiles content it was 0.127. The results of the paired t-test revealed that there was no significant difference between the NIR method and the standard method. The NIR spectroscopy method could be used to predict the resin, soluble resin and the volatiles content of the prepreg simultaneously, as well as sizing content of alkali-free cloth. The processing parameters of the prepreg during manufacture could be adjusted quickly with the help of the NIR analysis results. The results indicated that the NIR spectroscopy method was sufficiently accurate and effective for the on-line monitoring of alkali-free cloth/phenolic resin prepreg.

  15. Near Infrared Spectroscopy for On-line Monitoring of Alkali- Free Cloth/Phenolic Resin Prepreg During Manufacture

    OpenAIRE

    Jiang, Bo; Huang, Yu Dong

    2007-01-01

    A NIR method was developed for the on-line monitoring of alkali-free cloth/phenolic resin prepreg during its manufacturing process. First, the sizing content of the alkali-free cloth was analyzed, and then the resin, soluble resin and volatiles content of the prepreg was analyzed simultaneously using the FT-NIR spectrometer. Partial least square (PLS) regression was used to develop the calibration models, which for the sizing content was preprocessed by 1stDER +MSC, for the volatile content b...

  16. Liquid Resin Infusion process monitoring with embedded superimposed long period and short period Bragg grating sensor.

    Directory of Open Access Journals (Sweden)

    Robert L.

    2010-06-01

    Full Text Available We propose here the monitoring of the Liquid Resin Infusion (LRI process for using a superimposed long period (LPG and short period (FBG Bragg grating sensor. Monitoring of such a process is usually made measuring simultaneously temperature and strain by the use of an electro-optical device (FBG-Thermocouple. It has been shown that an applied solicitation is measured by a wavelength shift with a different sensitivity for LPG and FBG; thus strain and temperature influences can be determined separately by measuring corresponding wavelength shifts. The reported configuration is based on the use of these two Bragg gratings types written in the same fibre section, which allows us to discriminate the contributions of the temperature and strain. The sensor is embedded in a composite specimen manufactured by LRI process for monitoring in real time and simultaneously the applied temperature and strain.

  17. STIMULATING PASTES ON SYSTEM FOR RESIN FLOW OF Pinus elliottii var. elliottii

    Directory of Open Access Journals (Sweden)

    André Luiz Marretto Fusatto

    2013-08-01

    Full Text Available http://dx.doi.org/10.5902/1980509810559The use of stimulating pastes aims to increase the rate of resin flow and its time of duration. In the Forest Experiment Station of Itatinga, São Paulo state, 159 trees of Pinuselliottiivar. elliottiiwere were submitted to the treatments with 5 stimulant pastes, (Red Alchem, Paste with EthephonPlanebrás, Black Resin Brazil, Red Eldorado and Test Paste (Paraquat + Ethephon that was compared to the Control (Black Planebrás. Biweekly chipping and collects every three months were accomplished (from the result of 5 grooves, being determined the resin weight during 2.5 years. The application of stimulating pastes with ethephon did not show significant advantage about application of pastes without ethephon. The stimulant pastes applied were different in the weightings performed. In the treatments applied, the percentage of pitch ranged from 71.33% to 76.56% and the turpentine ranged from 10.37% to 13.78%. The yield of alpha-pinene ranged from 37.70% to 53.31%, and of beta-pinene from 34.34% to 50.41%.

  18. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Computerized flow monitors detect small kicks

    Energy Technology Data Exchange (ETDEWEB)

    McCann, D.; White, D. (Sedco Forex, Paris (FR))

    1992-02-24

    This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.

  20. Integrated Approach to Monitor Flow Accelerated Corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Ryu, Kyung Ha; Lee, Seung Gi; Hwang, Il Soon

    2005-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Flow Accelerated Corrosion (FAC), one of the hot issues in aged piping occurs due to many combined parameters. Therefore, we need to monitor as many parameters as possible, and that cover wide area, since we don' know where the FAC occurs. Therefore, we need diverse sensors which can cover wide area in the on-line application. Since FAC is a combined phenomenon, we reviewed parameters important to FAC occurrence, and then surveyed applicable sensors. First, we identified feasibility by analytical way, and then we developed electrochemical sensors for high temperature application. We also introduced mechanical monitoring system, which gathers thickness-dependent signals. These signals are indirect, and thus we need an interface which converts monitored results to an identical parameter. We introduced wearing rate model, which accepts the electrochemical parameters as inputs. By the model, we can predict the wearing rate and then we can compare the monitored electrochemical parameters with the thickness monitoring result as a validation. After the preliminary tests, we developed the FAC simulation test loop of high temperature and pressure, which is similar to the secondary part of the NPP. We changed pH and dissolved oxygen of the developed test loop to accelerate FAC. To support the validation of the monitored results, we also adopted high temperature UT, which shows good resolution in the testing environment. By this way, all the monitored results can be compared in terms of thickness

  1. Autoclave processing for composite material fabrication. 1: An analysis of resin flows and fiber compactions for thin laminate

    Science.gov (United States)

    Hou, T. H.

    1985-01-01

    High quality long fiber reinforced composites, such as those used in aerospace and industrial applications, are commonly processed in autoclaves. An adequate resin flow model for the entire system (laminate/bleeder/breather), which provides a description of the time-dependent laminate consolidation process, is useful in predicting the loss of resin, heat transfer characteristics, fiber volume fraction and part dimension, etc., under a specified set of processing conditions. This could be accomplished by properly analyzing the flow patterns and pressure profiles inside the laminate during processing. A newly formulated resin flow model for composite prepreg lamination process is reported. This model considers viscous resin flows in both directions perpendicular and parallel to the composite plane. In the horizontal direction, a squeezing flow between two nonporous parallel plates is analyzed, while in the vertical direction, a poiseuille type pressure flow through porous media is assumed. Proper force and mass balances have been made and solved for the whole system. The effects of fiber-fiber interactions during lamination are included as well. The unique features of this analysis are: (1) the pressure gradient inside the laminate is assumed to be generated from squeezing action between two adjacent approaching fiber layers, and (2) the behavior of fiber bundles is simulated by a Finitely Extendable Nonlinear Elastic (FENE) spring.

  2. Monitoring Photochemical Reactions Using Marangoni Flows

    Science.gov (United States)

    2017-01-01

    We evaluated the sensitivity and time resolution of a technique for photochemical reaction monitoring based on the interferometric detection of the deformation of liquid films. The reaction products change the local surface tension and induce Marangoni flow in the liquid film. As a model system, we consider the irradiation of the aliphatic hydrocarbon squalane with broadband deep-UV light. We developed a numerical model that quantitatively reproduces the flow patterns observed in the experiments. Moreover, we present self-similarity solutions that elucidate the mechanisms governing different stages of the dynamics and their parametric dependence. Surface tension changes as small as Δγ = 10–6 N/m can be detected, and time resolutions of <1 s can be achieved. PMID:28319399

  3. Scour monitoring via turbulent open channel flow

    International Nuclear Information System (INIS)

    Fisher, M; Khan, A; Atamturktur, S

    2013-01-01

    Scour is the leading cause of bridge failure in the United States. It can result in the loss of lives and costs millions to repair the damage. A novel method is proposed for monitoring scour that exploits the turbulence in natural channels. The method utilizes the dynamic pressure associated with the turbulent velocity fluctuations in the flow to excite a flexible plate. A semi-empirical model is developed to describe the interaction of turbulent open channel flow with the plate. The model describes the variation of turbulent velocity fluctuations across the flow depth in an open channel resulting in a method for determining the average dynamic pressure on the flexible plate. The dynamic response of the plate is then modeled by superimposing the response of multiple modes of the disk to the random, turbulent dynamic pressure spectrum. The model is verified considering the pressure integration across the plate surface to ensure converged solutions. Due to the uncertainties in the material properties of the plate, the experimentally determined natural frequencies and vibration measurements are used to calibrate the model. The calibrated model predictions are then compared against an independent dataset for validation. In addition to describing the physical operation of the device, the semi-empirical model is also employed to optimize the field device. Measurements made using the field device also confirmed the model results, even in a non-design, misaligned flow condition. (paper)

  4. NMR reaction monitoring in flow synthesis

    Directory of Open Access Journals (Sweden)

    M. Victoria Gomez

    2017-02-01

    Full Text Available Recent advances in the use of flow chemistry with in-line and on-line analysis by NMR are presented. The use of macro- and microreactors, coupled with standard and custom made NMR probes involving microcoils, incorporated into high resolution and benchtop NMR instruments is reviewed. Some recent selected applications have been collected, including synthetic applications, the determination of the kinetic and thermodynamic parameters and reaction optimization, even in single experiments and on the μL scale. Finally, software that allows automatic reaction monitoring and optimization is discussed.

  5. Custom 3D printer and resin for 18 μm × 20 μm microfluidic flow channels.

    Science.gov (United States)

    Gong, Hua; Bickham, Bryce P; Woolley, Adam T; Nordin, Gregory P

    2017-08-22

    While there is great interest in 3D printing for microfluidic device fabrication, to-date the achieved feature sizes have not been in the truly microfluidic regime (<100 μm). In this paper we demonstrate that a custom digital light processor stereolithographic (DLP-SLA) 3D printer and a specifically-designed, low cost, custom resin can readily achieve flow channel cross sections as small as 18 μm × 20 μm. Our 3D printer has a projected image plane resolution of 7.6 μm and uses a 385 nm LED, which dramatically increases the available selection of UV absorbers for resin formulation compared to 3D printers with 405 nm LEDs. Beginning with 20 candidate absorbers, we demonstrate the evaluation criteria and process flow required to develop a high-resolution resin. In doing so, we introduce a new mathematical model for characterizing the resin optical penetration depth based only on measurement of the absorber's molar absorptivity. Our final resin formulation uses 2-nitrophenyl phenyl sulfide (NPS) as the UV absorber. We also develop a novel channel narrowing technique that, together with the new resin and 3D printer resolution, enables small flow channel fabrication. We demonstrate the efficacy of our approach by fabricating 3D serpentine flow channels 41 mm long in a volume of only 0.12 mm 3 , and by printing high aspect ratio flow channels <25 μm wide and 3 mm tall. These results indicate that 3D printing is finally positioned to challenge the pre-eminence of methods such as soft lithography for microfluidic device prototyping and fabrication.

  6. An Analytical Vacuum-Assisted Resin Transfer Molding (VARTM) Flow Model

    National Research Council Canada - National Science Library

    Fink, Bruce

    2000-01-01

    .... The analytical solution presented here provides insight into the scaling laws governing fill times and resin inlet placement as a function of the properties of the preform, distribution media, and resin...

  7. A novel approach to water polution monitoring by combining ion exchange resin and XRF-scanning technique

    Science.gov (United States)

    Huang, J. J.; Lin, S. C.; Löwemark, L.; Liou, Y. H.; Chang, Q. M.; Chang, T. K.; Wei, K. Y.; Croudace, I. W. C.

    2017-12-01

    Due to the rapid industrial expansion, environments are subject to irregular fluctuations and spatial distributions in pollutant concentrations. This study proposes to use ion exchange resin accompanied with the XRF-scanning technique to monitor environmental pollution. As a passive sampling sorbent, the use of ion exchange resin provides a rapid, low cost and simple method to detect episodic pollution signals with a high spatial sampling density. In order to digest large quantities of samples, the fast and non-destructive Itrax-XRF core scanner has been introduced to assess elemental concentrations in the resin samples. Although the XRF scanning results are often considered as a semi-quantitative measurement due to possible absorption or scattering caused by the physical variabilities of scanned materials, the use of resin can minimize such influences owing to the standarization of the sample matrix. In this study, 17 lab-prepared standard resin samples were scanned with the Itrax-XRF core scanner (at 100 s exposure time with the Mo-tube) and compared with the absolute elemental concentrations. Six elements generally used in pollution studies (Cr, Mn, Ni, Cu, Zn, and Pb) were selected, and their regression lines and correlation coefficients were determined. In addition, 5 standard resin samples were scanned at different exposure time settings (1 s, 5 s, 15 s, 30 s, 100 s) to address the influence of exposure time on the accuracy of the measurements. The results show that within the test range (from few ppm to thousands ppm), the correlation coefficients are higher than 0.97, even at the shortest exposure time (1 s). Furthermore, a pilot field survey with 30 resin samples has been conducted in a potentially polluted farm area in central Taiwan to demonstrate the feasibility of this novel approach. The polluted hot zones could be identified and the properties and sources of wastewater pollution can therefore be traced over large areas for the purposes of

  8. Optical fiber sensors and their application in monitoring stress build-up in dental resin cements

    Science.gov (United States)

    Ottevaere, H.; Tabak, M.; Fernandez Fernandez, A.; Berghmans, F.; Thienpont, H.

    2005-09-01

    The field of optical fiber sensing is highly diverse and this diversity is perceived as a great advantage over more conventional sensors in that an optical sensor can be tailored to measure any of a myriad of physical parameters. In this paper we present a niche application for optical fiber sensors in the domain of biophotonics, namely the monitoring of stress build-up during the curing process of dental resin cements. We discuss the origin of this stress build-up and the problems it can cause when treating patients. Optical fiber sensors aim at excelling in two kind of applications: firstly to perform quality control on batch produced dental cements and measure their total material shrinkage, secondly to monitor the hardening of the cement during in-vivo measurements resulting in the dynamic measurement of the shrinkage and to control the stress in a facing based restoration. We therefore investigated two types of optical fiber sensors as alternatives to conventional measurement techniques; namely polarimetric optical fiber sensors and fiber Bragg gratings written in polarization maintaining fibers. After discussing the results obtained with both optical fiber sensors, we will conclude with a critical assessment of the suitability of the two proposed sensing configurations for multi-parameter stress monitoring.

  9. Flow monitoring explained: from packet capture to data analysis with NetFlow and IPFIX

    NARCIS (Netherlands)

    Hofstede, R.J.; Celeda, Pavel; Trammell, Brian; Drago, Idilio; Sadre, R.; Sperotto, Anna; Pras, Aiko

    2014-01-01

    Flow monitoring has become a prevalent method for monitoring traffic in high-speed networks. By focusing on the analysis of flows, rather than individual packets, it is often said to be more scalable than traditional packet-based traffic analysis. Flow monitoring embraces the complete chain of

  10. Method and apparatus for monitoring two-phase flow. [PWR

    Science.gov (United States)

    Sheppard, J.D.; Tong, L.S.

    1975-12-19

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  11. Near-Infrared Spectroscopic Method for Monitoring Water Content in Epoxy Resins and Fiber-Reinforced Composites

    Directory of Open Access Journals (Sweden)

    Andrey E. Krauklis

    2018-04-01

    Full Text Available Monitoring water content and predicting the water-induced drop in strength of fiber-reinforced composites are of great importance for the oil and gas and marine industries. Fourier transform infrared (FTIR spectroscopic methods are broadly available and often used for process and quality control in industrial applications. A benefit of using such spectroscopic methods over the conventional gravimetric analysis is the possibility to deduce the mass of an absolutely dry material and subsequently the true water content, which is an important indicator of water content-dependent properties. The objective of this study is to develop an efficient and detailed method for estimating the water content in epoxy resins and fiber-reinforced composites. In this study, Fourier transform near-infrared (FT-NIR spectroscopy was applied to measure the water content of amine-epoxy neat resin. The method was developed and successfully extended to glass fiber-reinforced composite materials. Based on extensive measurements of neat resin and composite samples of varying water content and thickness, regression was performed, and the quantitative absorbance dependence on water content in the material was established. The mass of an absolutely dry resin was identified, and the true water content was obtained. The method was related to the Beer–Lambert law and explained in such terms. A detailed spectroscopic method for measuring water content in resins and fiber-reinforced composites was developed and described.

  12. Near-Infrared Spectroscopic Method for Monitoring Water Content in Epoxy Resins and Fiber-Reinforced Composites.

    Science.gov (United States)

    Krauklis, Andrey E; Gagani, Abedin I; Echtermeyer, Andreas T

    2018-04-11

    Monitoring water content and predicting the water-induced drop in strength of fiber-reinforced composites are of great importance for the oil and gas and marine industries. Fourier transform infrared (FTIR) spectroscopic methods are broadly available and often used for process and quality control in industrial applications. A benefit of using such spectroscopic methods over the conventional gravimetric analysis is the possibility to deduce the mass of an absolutely dry material and subsequently the true water content, which is an important indicator of water content-dependent properties. The objective of this study is to develop an efficient and detailed method for estimating the water content in epoxy resins and fiber-reinforced composites. In this study, Fourier transform near-infrared (FT-NIR) spectroscopy was applied to measure the water content of amine-epoxy neat resin. The method was developed and successfully extended to glass fiber-reinforced composite materials. Based on extensive measurements of neat resin and composite samples of varying water content and thickness, regression was performed, and the quantitative absorbance dependence on water content in the material was established. The mass of an absolutely dry resin was identified, and the true water content was obtained. The method was related to the Beer-Lambert law and explained in such terms. A detailed spectroscopic method for measuring water content in resins and fiber-reinforced composites was developed and described.

  13. Traumatic resin ducts in Larix decidua stems impacted by debris flows.

    Science.gov (United States)

    Bollschweiler, Michelle; Stoffel, Markus; Schneuwly, Dominique M; Bourqui, Karin

    2008-02-01

    Following mechanical injury, stems of many conifers produce tangential rows of traumatic resin ducts (TRDs), the distribution of which has been used to date geomorphic events. However, little is known about how far TRD formation extends tangentially and axially from the point of injury or what the time course of TRD appearance is. We analyzed 28 injuries in eight Larix decidua Mill. tree stems resulting from debris flows in October 2000 and November 2004. Injuries occurred outside the period of cambial activity, and TRD formation occurred in the first layers of the growth ring formed in the year following that of injury. The axial extent of TRD formation averaged 74 cm and was greater above the injury than below it. At the height of the wound center, TRDs extended horizontally to a mean of 18% of the stem circumference excluding that portion where the cambium had been destroyed. In subsequent growth rings, TRDs, if present, were confined mainly to the height of the center of injury. Both the vertical and horizontal extent of TRD formation was related to the injury size. Within growth rings, the position of TRD formation changed with increasing distance from the wound progressing from early earlywood to later portions of the growth ring.

  14. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow.

    Science.gov (United States)

    Jiang, Peng; Zhao, Shuai; Zhu, Rong

    2015-12-15

    This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system.

  15. Flow Monitoring Experiences at the Ethernet-Layer

    NARCIS (Netherlands)

    Hofstede, Rick; Hofstede, R.J.; Drago, Idilio; Sperotto, Anna; Pras, Aiko; Lehnert, Ralf

    2011-01-01

    Flow monitoring is a scalable technology for providing summaries of network activity. Being deployed at the IP-layer, it uses fixed flow definitions, based on fields of the IP-layer and higher layers. Since several backbone network operators are considering the deployment of (Carrier) Ethernet in

  16. Systems and Sensors for Debris-flow Monitoring and Warning

    Directory of Open Access Journals (Sweden)

    Lorenzo Marchi

    2008-04-01

    Full Text Available Debris flows are a type of mass movement that occurs in mountain torrents. They consist of a high concentration of solid material in water that flows as a wave with a steep front. Debris flows can be considered a phenomenon intermediate between landslides and water floods. They are amongst the most hazardous natural processes in mountainous regions and may occur under different climatic conditions. Their destructiveness is due to different factors: their capability of transporting and depositing huge amounts of solid materials, which may also reach large sizes (boulders of several cubic meters are commonly transported by debris flows, their steep fronts, which may reach several meters of height and also their high velocities. The implementation of both structural and nonstructural control measures is often required when debris flows endanger routes, urban areas and other infrastructures. Sensor networks for debris-flow monitoring and warning play an important role amongst non-structural measures intended to reduce debris-flow risk. In particular, debris flow warning systems can be subdivided into two main classes: advance warning and event warning systems. These two classes employ different types of sensors. Advance warning systems are based on monitoring causative hydrometeorological processes (typically rainfall and aim to issue a warning before a possible debris flow is triggered. Event warning systems are based on detecting debris flows when these processes are in progress. They have a much smaller lead time than advance warning ones but are also less prone to false alarms. Advance warning for debris flows employs sensors and techniques typical of meteorology and hydrology, including measuring rainfall by means of rain gauges and weather radar and monitoring water discharge in headwater streams. Event warning systems use different types of sensors, encompassing ultrasonic or radar gauges, ground vibration sensors, videocameras, avalanche

  17. Calculating e-flow using UAV and ground monitoring

    Science.gov (United States)

    Zhao, C. S.; Zhang, C. B.; Yang, S. T.; Liu, C. M.; Xiang, H.; Sun, Y.; Yang, Z. Y.; Zhang, Y.; Yu, X. Y.; Shao, N. F.; Yu, Q.

    2017-09-01

    Intense human activity has led to serious degradation of basin water ecosystems and severe reduction in the river flow available for aquatic biota. As an important water ecosystem index, environmental flows (e-flows) are crucial for maintaining sustainability. However, most e-flow measurement methods involve long cycles, low efficiency, and transdisciplinary expertise. This makes it impossible to rapidly assess river e-flows at basin or larger scales. This study presents a new method to rapidly assessing e-flows coupling UAV and ground monitorings. UAV was firstly used to calculate river-course cross-sections with high-resolution stereoscopic images. A dominance index was then used to identify key fish species. Afterwards a habitat suitability index, along with biodiversity and integrity indices, was used to determine an appropriate flow velocity with full consideration of the fish spawning period. The cross-sections and flow velocity values were then combined into AEHRA, an e-flow assessment method for studying e-flows and supplying-rate. To verify the results from this new method, the widely used Tennant method was employed. The root-mean-square errors of river cross-sections determined by UAV are less than 0.25 m, which constitutes 3-5% water-depth of the river cross-sections. In the study area of Jinan city, the ecological flow velocity (VE) is equal to or greater than 0.11 m/s, and the ecological water depth (HE) is greater than 0.8 m. The river ecosystem is healthy with the minimum e-flow requirements being always met when it is close to large rivers, which is beneficial for the sustainable development of the water ecosystem. In the south river channel of Jinan, the upstream flow mostly meets the minimum e-flow requirements, and the downstream flow always meets the minimum e-flow requirements. The north of Jinan consists predominantly of artificial river channels used for irrigation. Rainfall rarely meets the minimum e-flow and irrigation water requirements

  18. Vibration monitoring for aircraft wing model using fiber Bragg grating array packaged by vacuum-assisted resin transfer molding

    Science.gov (United States)

    Zhang, Wen; Liu, Xiaolong; He, Wei; Dong, Mingli; Zhu, Lianqing

    2017-09-01

    For the improvement of monitoring accuracy, a vibration monitoring for aircraft wing model using a fiber Bragg grating (FBG) array packaged by vacuum-assisted resin transfer molding (VARTM) is proposed. The working principle of the vibration monitoring using FBG array has been explained, which can theoretically support the idea of this paper. VARTM has been explained in detail, which is suitable for not only the single FBG sensor but also the FBG array within a relatively large area. The calibration experiment has been performed using the FBG sensor packaged by VARTM. The strain sensitivity of the VARTM package is 1.35 pm/μɛ and the linearity is 0.9999. The vibration monitoring experiment has been carried out using FBG array packaged by VARTM. The measured rate of strain changes across the aluminum test board used to simulate the aircraft wing is 0.69 μɛ/mm and the linearity is 0.9931. The damping ratio is 0.16, which could be further used for system performance evaluation. Experimental results demonstrate that the vibration monitoring using FBG sensors packaged by VARTM can be efficiently used for the structural health monitoring. Given the validation and great performance, this method is quite promising for in-flight monitoring and holds great reference value in other similar engineering structures.

  19. Toward an operational use of debris-flow monitoring stations

    Science.gov (United States)

    Fontaine, Firmin; Bel, Coraline; Bellot, Hervé; Liébault, Frédéric

    2017-04-01

    The detection and the characterization of both debris flows and their occurrence conditions using monitoring stations was increasingly developed during the last two decades. The devices operate with various types of sensors and techniques, and in particular rain gauge, ground vibration sensors, flow stage sensors or video cameras. In case of debris-flow detection, such sensors make it possible to estimate the peak flow depth, the mean flow velocity, the flow discharge and the transported volume. These flow characteristics as well as the occurrence frequency are quantitative information relevant for hazard assessment. The multiplication of instrumented debris-flow prone sites could improve the evaluation of regional influences which affect, for instance, the occurrence conditions used in regional early-warning system. However, because debris-flow monitoring stations have to operate in harsh conditions and require both, strong maintenance and time-consuming post-processing, their use in operational context is still limited. A key element of the post-processing relies on the seismic signal from geophones. Indeed, such a signal is used for the recognition of the flow process involved and for estimating the surge velocity. Because very high frequency recording is not suitable for such monitoring stations, the seismic signal has to be conditioned while maintaining flow signature. We developed an electronic interface for analogically processing the raw signal, similarly to the so-called amplitude method: it allows us to preserve the signal energy while degrading the temporal resolution. For dealing with the continuum of sediment processes, from bedload transport to debris flow, but also with the sensor sensitivity to vibration source distance, the system has been adapted. A better characterization of the sediment transport process is expected. It should improve the automatic classification of rainfall events responsible for large, small and no flow occurrence. Finally

  20. Monitoring Subsurface Fluid Flow Using Perfluorocarbon Tracers: Another Tool Potentially Available for Subsurface Fluid Flow Assessments

    Science.gov (United States)

    Perfluorocarbon Tracers (PFTs) Complement stable Isotopes and Geochemistry for Verifying, Assessing or Modeling Fluid Flow. Geochemistry, Isotopes and PFT’s complement Geophysics to monitor and verify plume movement, leakage to shallow aquifers or surface

  1. Increased resin flow in mature pine trees growing under elevated CO2 and moderate soil fertility

    Science.gov (United States)

    K.A. Novick; G.G. Katul; H.R. McCarthy; R. Oren

    2012-01-01

    Warmer climates induced by elevated atmospheric CO2 (eCO2) are expected to increase damaging bark beetle activity in pine forests, yet the effect of eCO2 on resin production—the tree’s primary defense against beetle attack—remains largely unknown. Following growth-differentiation balance theory, if extra carbohydrates produced under eCO2 are not consumed by respiration...

  2. Determination of strontium-90 from direct separation of yttrium-90 by solid phase extraction using DGA Resin for seawater monitoring.

    Science.gov (United States)

    Tazoe, Hirofumi; Obata, Hajime; Yamagata, Takeyasu; Karube, Zin'ichi; Nagai, Hisao; Yamada, Masatoshi

    2016-05-15

    It is important for public safety to monitor strontium-90 in aquatic environments in the vicinity of nuclear related facilities. Strontium-90 concentrations in seawater exceeding the background level have been observed in accidents of nuclear facilities. However, the analytical procedure for measuring strontium-90 in seawater is highly demanding. Here we show a simple and high throughput analytical technique for the determination of strontium-90 in seawater samples using a direct yttrium-90 separation. The DGA Resin is used to determine the abundance of strontium-90 by detecting yttrium-90 decay (beta-emission) in secular equilibrium. The DGA Resin can selectively collect yttrium-90 and remove naturally occurring radionuclides such as (40)K, (210)Pb, (214)Bi, (238)U, and (232)Th and anthropogenic radionuclides such as (140)Ba, and (140)La. Through a sample separation procedure, a high chemical yield of yttrium-90 was achieved at 95.5±2.3%. The result of IAEA-443 certified seawater analysis (107.7±3.4 mBq kg(-1)) was in good agreement with the certified value (110±5 mBq kg(-1)). By developed method, we can finish analyzing 8 samples per day after achieving secular equilibrium, which is a reasonably fast throughput in actual seawater monitoring. By processing 3 L of seawater sample and applying a counting time of 20 h, minimum detectable activity can be as low as 1.5 mBq kg(-1), which could be applied to monitoring for the contaminated marine environment. Reproducibility was found to be 3.4% according to 10 independent analyses of natural seawater samples from the vicinity of the Fukushima Daiichi Nuclear Power Plant in September 2013. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A microcomputer-based gamma attenuation monitor for flowing liquids

    International Nuclear Information System (INIS)

    Everett, S.; Malcolme-Lawes, D.

    1984-01-01

    Many industrial processes involve large-scale flows of liquid mixtures or solutions in situations where it is desirable for the composition of the flow to be monitored. The attenuation (Isub(x)/I 0 ) of a beam of gamma photons can be used to provide a moderately sensitive means of monitoring mixture composition. Several applications of this technique to solid systems have been reported, and we have recently shown how the technique may be applied to monitoring the composition of a flowing liquid binary mixture. This paper describes a microcomputer-based apparatus which may be used to record the attenuation of a collimated beam of gamma photons by a liquid mixture flowing through a pipe. The apparatus and some example results obtained with trial mixtures are discussed. However, the sensitivity of the technique is determined both by the difference in u (the linear absorption coefficient of the matter concerned) for the materials which make up the mixture, and by the precision with which Isub(x)/I 0 may be monitored. For this reason we first consider the precision obtainable in the measurement of the intensity of a gamma photon beam. (author)

  4. Hardware implementation of the ORNL fissile mass flow monitor

    International Nuclear Information System (INIS)

    McEvers, J.; Sumner, J.; Jones, R.; Ferrell, R.; Martin, C.; Uckan, T.; March-Leuba, J.

    1998-01-01

    This paper provides an overall description of the implementation of the Oak Ridge National Laboratory (ORNL) Fissile Mass Flow Monitor, which is part of a Blend Down Monitoring System (BDMS) developed by the US Department of Energy (DOE). The Fissile Mass Flow Monitor is designed to measure the mass flow of fissile material through a gaseous or liquid process stream. It consists of a source-modulator assembly, a detector assembly, and a cabinet that houses all control, data acquisition, and supporting electronics equipment. The development of this flow monitor was first funded by DOE/NE in September 95, and an initial demonstration by ORNL was described in previous INMM meetings. This methodology was chosen by DOE/NE for implementation in November 1996, and the hardware/software development is complete. Successful BDMS installation and operation of the complete BDMS has been demonstrated in the Paducah Gaseous Diffusion Plant (PGDP), which is operated by Lockheed Martin Utility Services, Inc. for the US Enrichment Corporation and regulated by the Nuclear Regulatory Commission. Equipment for two BDMS units has been shipped to the Russian Federation

  5. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow

    Directory of Open Access Journals (Sweden)

    Peng Jiang

    2015-12-01

    Full Text Available This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system.

  6. Oxygen Mass Flow Rate Generated for Monitoring Hydrogen Peroxide Stability

    Science.gov (United States)

    Ross, H. Richard

    2002-01-01

    Recent interest in propellants with non-toxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because peroxide is sensitive to contaminants, material interactions, stability and storage issues, monitoring decomposition rates is important. Stennis Space Center (SSC) uses thermocouples to monitor bulk fluid temperature (heat evolution) to determine reaction rates. Unfortunately, large temperature rises are required to offset the heat lost into the surrounding fluid. Also, tank penetration to accomodate a thermocouple can entail modification of a tank or line and act as a source of contamination. The paper evaluates a method for monitoring oxygen evolution as a means to determine peroxide stability. Oxygen generation is not only directly related to peroxide decomposition, but occurs immediately. Measuring peroxide temperature to monitor peroxide stability has significant limitations. The bulk decomposition of 1% / week in a large volume tank can produce in excess of 30 cc / min. This oxygen flow rate corresponds to an equivalent temperature rise of approximately 14 millidegrees C, which is difficult to measure reliably. Thus, if heat transfer were included, there would be no temperature rise. Temperature changes from the surrounding environment and heat lost to the peroxide will also mask potential problems. The use of oxygen flow measurements provides an ultra sensitive technique for monitoring reaction events and will provide an earlier indication of an abnormal decomposition when compared to measuring temperature rise.

  7. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    Science.gov (United States)

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  8. Clustering and Flow Conservation Monitoring Tool for Software Defined Networks

    Directory of Open Access Journals (Sweden)

    Jesús Antonio Puente Fernández

    2018-04-01

    Full Text Available Prediction systems present some challenges on two fronts: the relation between video quality and observed session features and on the other hand, dynamics changes on the video quality. Software Defined Networks (SDN is a new concept of network architecture that provides the separation of control plane (controller and data plane (switches in network devices. Due to the existence of the southbound interface, it is possible to deploy monitoring tools to obtain the network status and retrieve a statistics collection. Therefore, achieving the most accurate statistics depends on a strategy of monitoring and information requests of network devices. In this paper, we propose an enhanced algorithm for requesting statistics to measure the traffic flow in SDN networks. Such an algorithm is based on grouping network switches in clusters focusing on their number of ports to apply different monitoring techniques. Such grouping occurs by avoiding monitoring queries in network switches with common characteristics and then, by omitting redundant information. In this way, the present proposal decreases the number of monitoring queries to switches, improving the network traffic and preventing the switching overload. We have tested our optimization in a video streaming simulation using different types of videos. The experiments and comparison with traditional monitoring techniques demonstrate the feasibility of our proposal maintaining similar values decreasing the number of queries to the switches.

  9. Monitoring Immune Responses in Organ Recipients by Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Al-Mukhalafi Zuha

    2001-01-01

    Full Text Available Allograft rejection remains a major barrier to successful organ transplan-tation. Cellular and humoral immune responses play a critical role in mediating graft rejection. During the last few years, monoclonal antibodies have been used as a new specific therapeutic approach in the prevention of allograft rejection. Recently, the technology of flow cytometry has become a useful tool for monitoring immunological responses in transplant recipients. The application of this valuable tool in clinical transplantation at the present time is aimed at, i determining the extent of immuno-suppressive therapy through T-cell receptor analysis of cellular components, ii monitoring levels of alloreactive antibodies to identify high-risk recipients (sensitized patients in the pre-operative period and iii to predict rejection by monitoring their development post-operatively. In future, further development of this technology may demonstrate greater benefit to the field of organ transplantation.

  10. Monitoring individual traffic flows within the ATLAS TDAQ network

    CERN Document Server

    Sjoen, R; Ciobotaru, M; Batraneanu, S M; Leahu, L; Martin, B; Al-Shabibi, A

    2010-01-01

    The ATLAS data acquisition system consists of four different networks interconnecting up to 2000 processors using up to 200 edge switches and five multi-blade chassis devices. The architecture of the system has been described in [1] and its operational model in [2]. Classical, SNMP-based, network monitoring provides statistics on aggregate traffic, but for performance monitoring and troubleshooting purposes there was an imperative need to identify and quantify single traffic flows. sFlow [3] is an industry standard based on statistical sampling which attempts to provide a solution to this. Due to the size of the ATLAS network, the collection and analysis of the sFlow data from all devices generates a data handling problem of its own. This paper describes how this problem is addressed by making it possible to collect and store data either centrally or distributed according to need. The methods used to present the results in a relevant fashion for system analysts are discussed and we explore the possibilities a...

  11. Monitoring individual traffic flows within the ATLAS TDAQ network

    International Nuclear Information System (INIS)

    Sjoen, R; Batraneanu, S M; Leahu, L; Martin, B; Al-Shabibi, A; Stancu, S; Ciobotaru, M

    2010-01-01

    The ATLAS data acquisition system consists of four different networks interconnecting up to 2000 processors using up to 200 edge switches and five multi-blade chassis devices. The architecture of the system has been described in [1] and its operational model in [2]. Classical, SNMP-based, network monitoring provides statistics on aggregate traffic, but for performance monitoring and troubleshooting purposes there was an imperative need to identify and quantify single traffic flows. sFlow [3] is an industry standard based on statistical sampling which attempts to provide a solution to this. Due to the size of the ATLAS network, the collection and analysis of the sFlow data from all devices generates a data handling problem of its own. This paper describes how this problem is addressed by making it possible to collect and store data either centrally or distributed according to need. The methods used to present the results in a relevant fashion for system analysts are discussed and we explore the possibilities and limitations of this diagnostic tool, giving an example of its use in solving system problems that arise during the ATLAS data taking.

  12. Physics design of fissile mass-flow monitoring system

    International Nuclear Information System (INIS)

    Mattingly, J.K.; March-Leuba, J.; Valentine, T.E.; Mihalczo, J.T.; Uckan, T.

    1997-01-01

    The system measures the flow rate and uranium-235 content in liquid or gas streams; it does not penetrate the process piping. A moderated fission neutron source is used to periodicially introduce a burst of thermal neutrons into the fluid stream to induce fission; delayed gamma emissions from the resulting fission fragments are detected by high-efficiency scintillators downstream of the neutron source. The fluid flow rate is measure from the time between initiation of the thermal neutron burst and detection of the fission product gamma emissions, and the U-235 content is inferred from the intensity of the gamma burst detected. Design of the fissile mass flow monitor requires satisfaction of several competing constraints. Efficient operation of the monitor requires that source-induced fission rate and detection efficiency be maximized while the source-induced background rate is simultaneoulsy minimized. Near optical nuclear design of the system was achieved using numerous Monte Carlo calculations and measurements. This paper addresses calculational aspects of the physics design for the system applied to UF 6 gas

  13. Downhole Measurements of Electrokinetic Potential to Monitor Flow in Oilfields

    Science.gov (United States)

    Saunders, J.; Jackson, M.; Pain, C.; Addiego-Guevara, E.

    2005-12-01

    Oil companies currently produce an average of three barrels of water for each barrel of oil, which is expensive and environmentally unfriendly: the produced water is contaminated and must be treated and disposed of carefully. Ideally, water production would be prevented or minimised by monitoring its movement within the reservoir and responding appropriately. We suggest that measurements of electrokinetic (or ' streaming') potential during oil production, using permanently installed downhole electrodes, could be used to monitor water encroachment towards a well before water breakthrough occurs. Electrokinetic potentials are generated when fluids flow through rock, and although they are increasingly being used in other areas of earth science to monitor subsurface flows, there has been little investigation of their utility in hydrocarbon reservoirs. We have used a new numerical model to simulate the electrokinetic potential measured at a well during oil production, with reservoir pressure maintained by water injection or aquifer influx. Our results suggest that encroaching water causes changes in the electrokinetic potential at the well which could be resolved above background electrical noise; indeed, water approaching the well could be monitored several 10s to 100s of metres away. Our results differ from those obtained previously, because we include the results of recent laboratory experiments which provide new insight into the nature of the coupling between fluid and electrokinetic potentials as the oil saturation changes. Moreover, we investigate a range of production rates which are more appropriate for modern offshore developments, and simulate the potential measured at electrodes installed at the producing well rather than at a nearby monitoring well or at the surface. Electrodes mounted downhole on insulated casing have been successfully applied in subsurface resistivity surveys during oil production, and similar technology could be used to measure

  14. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Science.gov (United States)

    2010-04-01

    ... monitor the amount of fluid being infused into a patient. The device consists of an electronic transducer... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems...

  15. Long-term flow monitoring of submarine gas emanations

    Science.gov (United States)

    Spickenbom, K.; Faber, E.; Poggenburg, J.; Seeger, C.

    2009-04-01

    One of the Carbon Capture and Storage (CCS) strategies currently under study is the sequestration of CO2 in sub-seabed geological formations. Even after a thorough review of the geological setting, there is the possibility of leaks from the reservoirs. As part of the EU-financed project CO2ReMoVe (Research, Monitoring, Verification), which aims to develop innovative research and technologies for monitoring and verification of carbon dioxide geological storage, we are working on the development of submarine long-term gas flow monitoring systems. Technically, however, these systems are not limited to CO2 but can be used for monitoring of any free gas emission (bubbles) on the seafloor. The basic design of the gas flow sensor system was derived from former prototypes developed for monitoring CO2 and CH4 on mud volcanoes in Azerbaijan. This design was composed of a raft floating on the surface above the gas vent to collect the bubbles. Sensors for CO2 flux and concentration and electronics for data storage and transmission were mounted on the raft, together with battery-buffered solar panels for power supply. The system was modified for installation in open sea by using a buoy instead of a raft and a funnel on the seafloor to collect the gas, which is then guided above water level through a flexible tube. Besides some technical problems (condensed water in the tube, movement of the buoys due to waves leading to biased measurement of flow rates), this setup provides a cost-effective solution for shallow waters. However, a buoy interferes with ship traffic, and it is also difficult to adapt this design to greater water depths. These requirements can best be complied by a completely submersed system. To allow unattended long-term monitoring in a submarine environment, such a system has to be extremely durable. Therefore, we focussed on developing a mechanically and electrically as simple setup as possible, which has the additional advantage of low cost. The system

  16. Fluid flow measurements by means of vibration monitoring

    Science.gov (United States)

    Campagna, Mauro M.; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano

    2015-11-01

    The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology.

  17. Fluid flow measurements by means of vibration monitoring

    International Nuclear Information System (INIS)

    Campagna, Mauro M; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano

    2015-01-01

    The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology. (paper)

  18. Resin impregnation process for producing a resin-fiber composite

    Science.gov (United States)

    Palmer, Raymond J. (Inventor); Moore, William E. (Inventor)

    1994-01-01

    Process for vacuum impregnation of a dry fiber reinforcement with a curable resin to produce a resin-fiber composite, by drawing a vacuum to permit flow of curable liquid resin into and through a fiber reinforcement to impregnate same and curing the resin-impregnated fiber reinforcement at a sufficient temperature and pressure to effect final curing. Both vacuum and positive pressure, e.g. autoclave pressure, are applied to the dry fiber reinforcement prior to application of heat and prior to any resin flow to compact the dry fiber reinforcement, and produce a resin-fiber composite of reduced weight, thickness and resin content, and improved mechanical properties. Preferably both a vacuum and positive pressure, e.g. autoclave pressure, are also applied during final curing.

  19. Managing Multi-center Flow Cytometry Data for Immune Monitoring.

    Science.gov (United States)

    White, Scott; Laske, Karoline; Welters, Marij Jp; Bidmon, Nicole; van der Burg, Sjoerd H; Britten, Cedrik M; Enzor, Jennifer; Staats, Janet; Weinhold, Kent J; Gouttefangeas, Cécile; Chan, Cliburn

    2014-01-01

    With the recent results of promising cancer vaccines and immunotherapy1-5, immune monitoring has become increasingly relevant for measuring treatment-induced effects on T cells, and an essential tool for shedding light on the mechanisms responsible for a successful treatment. Flow cytometry is the canonical multi-parameter assay for the fine characterization of single cells in solution, and is ubiquitously used in pre-clinical tumor immunology and in cancer immunotherapy trials. Current state-of-the-art polychromatic flow cytometry involves multi-step, multi-reagent assays followed by sample acquisition on sophisticated instruments capable of capturing up to 20 parameters per cell at a rate of tens of thousands of cells per second. Given the complexity of flow cytometry assays, reproducibility is a major concern, especially for multi-center studies. A promising approach for improving reproducibility is the use of automated analysis borrowing from statistics, machine learning and information visualization21-23, as these methods directly address the subjectivity, operator-dependence, labor-intensive and low fidelity of manual analysis. However, it is quite time-consuming to investigate and test new automated analysis techniques on large data sets without some centralized information management system. For large-scale automated analysis to be practical, the presence of consistent and high-quality data linked to the raw FCS files is indispensable. In particular, the use of machine-readable standard vocabularies to characterize channel metadata is essential when constructing analytic pipelines to avoid errors in processing, analysis and interpretation of results. For automation, this high-quality metadata needs to be programmatically accessible, implying the need for a consistent Application Programming Interface (API). In this manuscript, we propose that upfront time spent normalizing flow cytometry data to conform to carefully designed data models enables automated

  20. Evaluation of diffusive gradients in thin-films using a Diphonix{sup ®} resin for monitoring dissolved uranium in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Geraldine S.C. [School of Earth and Environmental Sciences, University of Portsmouth, Burnaby Building, Burnaby Road, Portsmouth, Hampshire PO1 3QL (United Kingdom); Mills, Graham A. [School of Pharmacy and Biomedical Sciences, University of Portsmouth, St. Michael’s Building, White Swan Road, Portsmouth, Hampshire PO1 2DT (United Kingdom); Burnett, Jonathan L.; Amos, Sean [AWE Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Fones, Gary R., E-mail: gary.fones@port.ac.uk [School of Earth and Environmental Sciences, University of Portsmouth, Burnaby Building, Burnaby Road, Portsmouth, Hampshire PO1 3QL (United Kingdom)

    2015-01-07

    Highlights: • Diphonix{sup ®} actinide specific resin was investigated for use with DGT to monitor U. • Uptake of U was unaffected by changes in aqueous pH, ionic strength, Ca{sup 2+} and CO{sub 3}{sup −}. • Diphonix{sup ®}-DGT can quantitatively measure U in fresh water over a 7 day deployment. • Matrix effects limited extended deployments in marine waters. • The device was able to measure precisely and accurately isotopic ratios of U. - Abstract: Commercially available Diphonix{sup ®} resin (TrisKem International) was evaluated as a receiving phase for use with the diffusive gradients in thin-films (DGT) passive sampler for measuring uranium. This resin has a high partition coefficient for actinides and is used in the nuclear industry. Other resins used as receiving phases with DGT for measuring uranium have been prone to saturation and significant chemical interferences. The performance of the device was evaluated in the laboratory and in field trials. In laboratory experiments uptake of uranium (all 100% efficiency) by the resin was unaffected by varying pH (4–9), ionic strength (0.01–1.00 M, as NaNO{sub 3}) and varying aqueous concentrations of Ca{sup 2+} (100–500 mg L{sup −1}) and HCO{sub 3}{sup −} (100–500 mg L{sup −1}). Due to the high partition coefficient of Diphonex{sup ®}, several elution techniques for uranium were evaluated. The optimal eluent mixture was 1 M NaOH/1 M H{sub 2}O{sub 2}, eluting 90% of the uranium from the resin. Uptake of uranium was linear (R{sup 2} = 0.99) over time (5 days) in laboratory experiments using artificial freshwater showing no saturation effects of the resin. In field deployments (River Lambourn, UK) the devices quantitatively accumulated uranium for up to 7 days. In both studies uptake of uranium matched that theoretically predicted for the DGT. Similar experiments in seawater did not follow the DGT theoretical uptake and the Diphonix{sup ®} appeared to be capacity limited and also affected

  1. Sonification of network traffic flow for monitoring and situational awareness.

    Science.gov (United States)

    Debashi, Mohamed; Vickers, Paul

    2018-01-01

    Maintaining situational awareness of what is happening within a computer network is challenging, not only because the behaviour happens within machines, but also because data traffic speeds and volumes are beyond human ability to process. Visualisation techniques are widely used to present information about network traffic dynamics. Although they provide operators with an overall view and specific information about particular traffic or attacks on the network, they often still fail to represent the events in an understandable way. Also, because they require visual attention they are not well suited to continuous monitoring scenarios in which network administrators must carry out other tasks. Here we present SoNSTAR (Sonification of Networks for SiTuational AwaReness), a real-time sonification system for monitoring computer networks to support network administrators' situational awareness. SoNSTAR provides an auditory representation of all the TCP/IP traffic within a network based on the different traffic flows between between network hosts. A user study showed that SoNSTAR raises situational awareness levels by enabling operators to understand network behaviour and with the benefit of lower workload demands (as measured by the NASA TLX method) than visual techniques. SoNSTAR identifies network traffic features by inspecting the status flags of TCP/IP packet headers. Combinations of these features define particular traffic events which are mapped to recorded sounds to generate a soundscape that represents the real-time status of the network traffic environment. The sequence, timing, and loudness of the different sounds allow the network to be monitored and anomalous behaviour to be detected without the need to continuously watch a monitor screen.

  2. Enhancement of adhesion between resin coating materials and resin cements.

    Science.gov (United States)

    Udo, Tomoaki; Nikaido, Toru; Ikeda, Masaomi; Weerasinghe, Dinesh S; Harada, Naoko; Foxton, Richard M; Tagami, Junji

    2007-07-01

    Resin coating technique is a unique method that improves the dentin bond strength of resin cements in indirect restorations. However, the weak link of a specimen bonded using the resin coating technique was reported to be the bonded interface between the resin coating material and resin cement. The purpose of this study, therefore, was to enhance the bonding performance between a resin coating material and a resin cement. Two light-cured flowable composites, Protect Liner F and Clearfil Flow FX, were used as coating materials, and two dual-cure composite materials, Panavia F 2.0 and Clearfil DC Core Automix, were used as resin cements. The ultimate tensile strength of each material and the microtensile bond strengths of the bonded specimens of resin coating material and resin cement were measured using a crosshead speed of 1.0 mm/min. Three-way ANOVA (p=0.05) revealed that the highest microtensile bond strength was obtained using a combination of Clearfil Flow FX and Clearfil DC Core Automix, and when the surface of the coating material was treated with ED Primer II. It was strongly suggested that materials with a higher ultimate tensile strength, when used in both resin coating and cementation, could enhance the bond strength between the two.

  3. Modeling flow cytometry data for cancer vaccine immune monitoring.

    Science.gov (United States)

    Frelinger, Jacob; Ottinger, Janet; Gouttefangeas, Cécile; Chan, Cliburn

    2010-09-01

    Flow cytometry (FCM) is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. In all these applications, the challenge is to detect extremely rare cell subsets while avoiding spurious positive events. To achieve this objective, it helps to be able to analyze FCM data using multiple markers simultaneously, since the additional information provided often helps to minimize the number of false positive and false negative events, hence increasing both sensitivity and specificity. However, with manual gating, at most two markers can be examined in a single dot plot, and a sequential strategy is often used. As the sequential strategy discards events that fall outside preceding gates at each stage, the effectiveness of the strategy is difficult to evaluate without laborious and painstaking back-gating. Model-based analysis is a promising computational technique that works using information from all marker dimensions simultaneously, and offers an alternative approach to flow analysis that can usefully complement manual gating in the design of optimal gating strategies. Results from model-based analysis will be illustrated with examples from FCM assays commonly used in cancer immunotherapy laboratories.

  4. Tailoring the Spacer Arm for Covalent Immobilization of Candida antarctica Lipase B—Thermal Stabilization by Bisepoxide-Activated Aminoalkyl Resins in Continuous-Flow Reactors

    Directory of Open Access Journals (Sweden)

    Emese Abaházi

    2016-06-01

    Full Text Available An efficient and easy-to-perform method was developed for immobilization of CaLB on mesoporous aminoalkyl polymer supports by bisepoxide activation. Polyacrylate resins (100–300 µm; ~50 nm pores with different aminoalkyl functional groups (ethylamine: EA and hexylamine: HA were modified with bisepoxides differing in the length, rigidity and hydrophobicity of the units linking the two epoxy functions. After immobilization, the different CaLB preparations were evaluated using the lipase-catalyzed kinetic resolution (KR of racemic 1-phenylethanol (rac-1 in batch mode and in a continuous-flow reactor as well. Catalytic activity, enantiomer selectivity, recyclability, and the mechanical and long-term stability of CaLB immobilized on the various supports were tested. The most active CaLB preparation (on HA-resin activated with 1,6-hexanediol diglycidyl ether—HDGE retained 90% of its initial activity after 13 consecutive reaction cycles or after 12 month of storage at 4 °C. The specific rate (rflow, enantiomer selectivity (E and enantiomeric excess (ee achievable with the best immobilized CaLB preparations were studied as a function of temperature in kinetic resolution of rac-1 performed in continuous-flow packed-bed bioreactors. The optimum temperature of the most active HA-HDGE CaLB in continuous-flow mode was 60 °C. Although CaLB immobilized on the glycerol diglycidyl ether (GDGE-activated EA-resin was less active and less selective, a much higher optimum temperature (80 °C was observed with this form in continuous-flow mode KR of rac-1.

  5. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    Science.gov (United States)

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  6. Variation in blood flow of supporting tissue during use of mandibular complete dentures with hard acrylic resin base and soft relining: a preliminary study.

    Science.gov (United States)

    Kocabalkan, Engin; Turgut, Mehmet

    2005-01-01

    This study investigated the influence of hard and resilient polymerized acrylic resin base materials on the blood flow of the supporting underlying mucosa of mandibular denture wearers during different denture-wearing periods. Measurements were carried out on 20 complete denture wearers, 10 with hard bases and 10 with soft ones. The mucosal blood flow underlying the dentures was measured bilaterally in the canine and molar regions using a laser Doppler flowmeter. Baseline measurements were performed before denture wearing and after the dentures were worn for 1 week, 1 month, 3 months, and 6 months. Mean blood flow to the mucosa after 1 week was significantly lower in the measured regions than that obtained before the dentures were worn. Blood flow in the canine region returned to almost normal levels 6 months after beginning to wear complete dentures. However, blood flow in the molar region of the denture wearers in the hard base group increased after 6 months, whereas blood flow values did not return to the levels recorded before denture insertion in the soft lining group. It appears that wearing dentures hinders blood flow to denture-supporting tissues, even when soft liners are used.

  7. Numerical modelling of the flow in the resin infusion process on the REV scale: A feasibility study

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Jambhekar, V. A.; Gersborg, A. R.

    2016-01-01

    The resin infusion process (RIP) has developed as a low cost method for manufacturing large fibre reinforced plastic parts. However, the process still presents some challenges to industry with regards to reliability and repeatability, resulting in expensive and inefficient trial and error...

  8. Go with the flow: conservation of a floating sculpture from 1961 made from glass fibre-reinforced polyester resin

    NARCIS (Netherlands)

    Beerkens, L.; Stigter, S.; van Oosten, T.; van Keulen, H.; Keneghan, B.; Egan, L.

    2008-01-01

    Marta Pan’s Sculpture flottante, Otterlo was commissioned by the Kröller-Müller Museum for a pond at the entrance of the new sculpture garden that opened in June 1961. The floating sculpture is made from glass fibre-reinforced polyester resin and is now coated with white paint layers. The top is

  9. Optimization of the resin application on the purification system of ISFSF RSG-GAS

    International Nuclear Information System (INIS)

    Junaidi

    1998-01-01

    The purification system in the spent fuel storage is to maintain the coolant water quality to the constant. This system uses the resin of IRN 77-Anion in the mixed bed filter as contamination capture. The returned water flow to the storage will be analyzed to the monitor the bed efficiency. This system can be optimally operated if the mixed bed is contained by 200 liters of resin and this is equivalent with the 0.5 m high of bed and 0.75 m in diameter. The resin must be flushed to be cleaned or changed when the pressure difference in the bed filter is higher than 0.5 bar

  10. A new debris flow monitoring barrier to measure debris flow impact/structure/ground interaction in the Gadria torrent

    Science.gov (United States)

    Nagl, Georg; Hübl, Johannes

    2017-04-01

    Debris flow monitoring is a keystone in debris flow research. Based on the lack of investigations of the interaction of rapid mass movement and structural mitigation measures, a new monitoring system has been installed in the well monitored Gadria torrent in South Tyrol. For design of active structural measures, like check dams, the engineering task is to come to an amicable solution of all necessary subjects. Starting with the estimation of parameters of the rapid mass movement itself to the design load and finally to the foundation of the structure. At all stages big uncertainties are given. The basis for accurate design is a comprehensive approach. For this reason, a new monitoring station was built in autumn 2016, to investigate the interaction of a debris flow with the structures and the ground. Two structures unify the new monitoring system. The first, a transversal check dam, flush to channel bed, contain two weighing devices each equipped with a pore pressure sensor. One device is also able to measure the shear force additional in two directions. The second barrier similar to a debris flow breaker but only with one singe wall centered on a foundation plate, is located downstream to the first one. 14 load cells are installed on the upward front of the structure to analyze the spatial force distribution of debris flow impact pressure. Nine earth pressure sensors under the foundation of the structure deliver the earth pressure distribution. The acceleration of the construction can be measured by a 3D accelerometer installed on the top. In case of a movement, two extensometers detect any displacement. Mounted strain gauges give insights of stresses in concrete and reinforcement. Each sensor has a sampling frequency of 2400 Hz. Furthermore it is planned to measure the flow velocity distribution over flow depth too. The new monitoring station should help to acquire data for understanding the debris flow/structure/ground interaction to facilitate the improvement

  11. Integrated Cantilever-Based Flow Sensors with Tunable Sensitivity for In-Line Monitoring of Flow Fluctuations in Microfluidic Systems

    Directory of Open Access Journals (Sweden)

    Nadine Noeth

    2013-12-01

    Full Text Available For devices such as bio-/chemical sensors in microfluidic systems, flow fluctuations result in noise in the sensor output. Here, we demonstrate in-line monitoring of flow fluctuations with a cantilever-like sensor integrated in a microfluidic channel. The cantilevers are fabricated in different materials (SU-8 and SiN and with different thicknesses. The integration of arrays of holes with different hole size and number of holes allows the modification of device sensitivity, theoretical detection limit and measurement range. For an average flow in the microliter range, the cantilever deflection is directly proportional to the flow rate fluctuations in the microfluidic channel. The SiN cantilevers show a detection limit below 1 nL/min and the thinnest SU-8 cantilevers a detection limit below 5 nL/min. Finally, the sensor is applied for in-line monitoring of flow fluctuations generated by external pumps connected to the microfluidic system.

  12. Integrated cantilever-based flow sensors with tunable sensitivity for in-line monitoring of flow fluctuations in microfluidic systems

    DEFF Research Database (Denmark)

    Noeth, Nadine-Nicole; Keller, Stephan Sylvest; Boisen, Anja

    2014-01-01

    For devices such as bio-/chemical sensors in microfluidic systems, flow fluctuations result in noise in the sensor output. Here, we demonstrate in-line monitoring of flow fluctuations with a cantilever-like sensor integrated in a microfluidic channel. The cantilevers are fabricated in different...... materials (SU-8 and SiN) and with different thicknesses. The integration of arrays of holes with different hole size and number of holes allows the modification of device sensitivity, theoretical detection limit and measurement range. For an average flow in the microliter range, the cantilever deflection...... is directly proportional to the flow rate fluctuations in the microfluidic channel. The SiN cantilevers show a detection limit below 1 nL/min and the thinnest SU-8 cantilevers a detection limit below 5 nL/min. Finally, the sensor is applied for in-line monitoring of flow fluctuations generated by external...

  13. Optical System for Monitoring Net Occular Blood Flow, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Physical Sciences Inc. (PSI) proposes to develop a novel ophthalmic imaging platform for the characterization and monitoring of visual impairment observed in...

  14. Note: Signal conditioning of a hot-film anemometer for a periodic flow rate monitoring system.

    Science.gov (United States)

    Mantovani, Federico; Tagliaferri, Cristian

    2011-12-01

    A flow monitoring system based on a constant temperature hot-film anemometer is presented. The device has been designed to monitor a dispensing process of extremely low quantities of adhesive material. The monitoring device presented in this paper is useful in industrial applications where exact flow speed tracking is not needed, but reliability and tolerance to parameters variability are essential. During the design of the device, problems related to the physical characteristic of the calorimetric sensor, in particular its thermal capacitance, and to the periodic nature of the monitored flow have been taken into account and suitable solutions have been implemented. The schematic representation of the monitoring device together with the experimental results obtained by monitoring fluids with different physical characteristics are presented.

  15. The effects of material loading and flow rate on the disinfection of pathogenic microorganisms using cation resin-silver nanoparticle filter system

    Science.gov (United States)

    Mpenyana-Monyatsi, L.; Mthombeni, N. H.; Onyango, M. S.; Momba, M. N. B.

    2017-08-01

    Waterborne diseases have a negative impact on public health in instances where the available drinking water is of a poor quality. Decentralised systems are needed to provide safe drinking water to rural communities. Therefore, the present study aimed to develop and investigate the point-of-use (POU) water treatment filter packed with resin-coated silver nanoparticles. The filter performance was evaluated by investigating the effects of various bed masses (10 g, 15 g, 20 g) and flow rates (2 mL/min, 5 mL/min, 10 mL/min) by means of breakthrough curves for the removal efficiency of presumptive Escherichia coli, Shigella dysenteriae, Salmonella typhimurium and Vibrio cholerae from spiked groundwater samples. The results revealed that, as the bed mass increases the breakthrough time also increases with regards to all targeted microorganisms. However, when the flow rate increases the breakthrough time decreased. These tests demonstrated that resin-coated silver nanoparticle can be an effective material in removing all targeted microorganisms at 100% removal efficiency before breakthrough points are achieved. Moreover the filter system demonstrated that it is capable of producing 15 L/day of treated water at an operating condition of 10 mL/min flow rate and 15 g bed mass, which is sufficient to provide for seven individuals in the household if they consume 2 L/person/day for drinking purpose. Therefore, the bed mass of the filter system should be increased in order for it to produce sufficient water that will conform to the daily needs of an individual.

  16. Traumatic resin ducts as indicators of bark beetle outbreaks

    Science.gov (United States)

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  17. Flow-injection spectrophotometric determination of captopril in pharmaceutical formulations using a new solid-phase reactor containing AgSCN immobilized in a polyurethane resin

    Directory of Open Access Journals (Sweden)

    Fernando Campanhã Vicentini

    2012-06-01

    Full Text Available A simple flow-injection analysis procedure was developed for determining captopril in pharmaceutical formulations employing a novel solid-phase reactor containing silver thiocyanate immobilized in a castor oil derivative polyurethane resin. The method was based on silver mercaptide formation between the captopril and Ag(I in the solid-phase reactor. During such a reaction, the SCN- anion was released and reacted with Fe3+, which generated the FeSCN2+ complex that was continuously monitored at 480 nm. The analytical curve was linear in the captopril concentration range from 3.0 × 10-4 mol L-1 to 1.1 × 10-3 mol L-1 with a detection limit of 8.0 × 10-5 mol L-1. Recoveries between 97.5% and 103% and a relative standard deviation of 2% for a solution containing 6.0 × 10-4 mol L-1 captopril (n = 12 were obtained. The sample throughput was 40 h-1 and the results obtained for captopril in pharmaceutical formulations using this procedure and those obtained using a pharmacopoeia procedure were in agreement at a 95% confidence level.Um procedimento simples de análise por injeção em fluxo foi desenvolvido para a determinação de captopril em formulações farmacêuticas empregando um novo reator em fase sólida contendo tiocianato de prata imobilizado em resina poliuretana obtida a partir de óleo de mamona. O método foi baseado na formação de um mercapto composto de prata, no reator em fase sólida, obtido entre o captopril e Ag (I imobilizada. Durante a reação, íons SCN- eram liberados e reagiam com Fe3+, gerando o complexo FeSCN2+, que foi continuamente monitorado em 480 nm. A curva analítica foi linear no intervalo de concentração de captopril entre 3,0 × 10-4 a 1,1 × 10-3 mol L-1 com um limite de detecção de 8,0 × 10-5 mol L-1. Recuperações entre 97,5-103% e desvio padrão relativo de 2% para uma solução contendo 6,0 × 10-4 mol L-1 de captopril (n = 12 foram obtidos. A frequência de amostragem foi de 40 h-1 e os resultados

  18. Statistical analysis on the signals monitoring multiphase flow patterns in pipeline-riser system

    Science.gov (United States)

    Ye, Jing; Guo, Liejin

    2013-07-01

    The signals monitoring petroleum transmission pipeline in offshore oil industry usually contain abundant information about the multiphase flow on flow assurance which includes the avoidance of most undesirable flow pattern. Therefore, extracting reliable features form these signals to analyze is an alternative way to examine the potential risks to oil platform. This paper is focused on characterizing multiphase flow patterns in pipeline-riser system that is often appeared in offshore oil industry and finding an objective criterion to describe the transition of flow patterns. Statistical analysis on pressure signal at the riser top is proposed, instead of normal prediction method based on inlet and outlet flow conditions which could not be easily determined during most situations. Besides, machine learning method (least square supported vector machine) is also performed to classify automatically the different flow patterns. The experiment results from a small-scale loop show that the proposed method is effective for analyzing the multiphase flow pattern.

  19. Balanced monitoring of flow phenomena in moving mesh methods

    NARCIS (Netherlands)

    van Dam, A.; Zegeling, P.A.

    2010-01-01

    Adaptive moving mesh research usually focuses either on analytical derivations for prescribed solutions or on pragmatic solvers with challenging physical applications. In the latter case, the monitor functions that steer mesh adaptation are often defined in an ad-hoc way. In this paper we generalize

  20. Refractometric monitoring of dissolution and fluid flow with distributed feedback dye laser sensor

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Sørensen, Kristian Tølbøl; Gade, Carsten

    2015-01-01

    Monitoring the dissolution of solid material in liquids and monitoring of fluid flow is of significant interest for applications in chemistry, food production, medicine, and especially in the fields of microfluidics and lab on a chip. Here, real-time refractometric monitoring of dissolution...... and fast fluid flow with DFB dye laser sensors with an optical imaging spectroscopy setup is presented. The dye laser sensors provide both low detection limits and high spatial resolution. It is demonstrated how the materials NaCl, sucrose, and bovine serum albumin show characteristic dissolution patterns...

  1. Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Moreno, Raul A.; Gismera, M.J.; Sevilla, M.T.; Procopio, Jesus R. [Facultad de Ciencias, Universidad Autonoma de Madrid, Departamento de Quimica Analitica y Analisis Instrumental, Madrid (Spain)

    2010-05-15

    A disposable screen-printed electrode was designed and evaluated for direct detection of chromium(VI) in batch and flow analysis. The carbon screen-printed electrode was modified with a graphite-epoxy composite. The optimal graphite-epoxy matrix contains 37.5% graphite powder, 12.5% diphenylcarbohydrazide, a selective compound for chromium(VI), and 50% epoxy resin. The principal analytical parameters of the potentiometric response in batch and flow analysis were optimized and calculated. The screen-printed sensor exhibits a response time of 20 {+-} 1 s. In flow analysis, the analytical frequency of sampling is 70 injections per hour using 0.1 M NaNO{sub 3} solution at pH 3 as the carrier, a flow rate of 2.5 mL.min{sup -1}, and an injection sample volume of 0.50 mL. The sensor shows potentiometric responses that are very selective for chromium(VI) ions and optimal detection limits in both static mode (2.1 x 10{sup -7} M) and online analysis (9.4 x 10{sup -7} M). The disposable potentiometric sensor was employed to determine toxicity levels of chromium(VI) in mineral, tap, and river waters by flow-injection potentiometry and batch potentiometry. Chromium(VI) determination was also carried out with successful results in leachates from municipal solid waste landfills. (orig.)

  2. Flow cytofluorometric monitoring of leukocyte apoptosis in experimental cholera

    Science.gov (United States)

    Lotsmanova, Ekaterina Y.; Kravtsov, Alexander L.; Livanova, Ludmila F.; Kobkova, Irina M.; Kuznetsov, Oleg S.; Shchukovskaya, Tatyana N.; Smirnova, Nina I.; Kutyrev, Vladimir V.

    2003-10-01

    Flow cytofluorometric DNA analysis was applied to determine of the relative contents of proliferative (more then 2C DNA per cell) and apoptotic (less then 2C DNA per cell) leukocytes in blood of adult rabbits, challenged with 10,000 times the 50 % effective dose of Vibrio cholerae virulent strain by the RITARD technique. It has been shown that irreversible increase the percentage of cells carrying DNA in the degradation stage brings to disbalance between the genetically controlled cell proliferation and apoptosis that leads to animal death from the cholera infection. Such fatal changes were not observed in challenging of immunized animals that were not died. Thus received data show that the flow cytofluorometric measurements may be used for detection of transgressions in homeostasis during acute infection diseases, for outlet prognosis of the cholera infection.

  3. A combined experimental and simulation based approach to model the flow-front dynamics in the vacuum assisted resin transfer moulding process

    DEFF Research Database (Denmark)

    Nauheimer, Michael; Relan, Rishi; Madsen, Henrik

    2017-01-01

    composites, without the possibility of visual inspection of the infusion process calls for a sensor system (possibly virtual) for monitoring the process. This paper proposes a two-step modelling methodology to identify the parameters related to the flow-front that are essential for determining the current...

  4. Monitoring drilling mud composition using flowing liquid junction electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Jasinski, R.; Fletcher, P.; Vercaemer, C.

    1990-06-27

    The concentration of a chosen ionic component of a drilling mud is determined from the potential difference between an ion selective electrode, selective to the component and a reference electrode, the reference electrode being connected to the mud by a liquid junction through which reference electrolyte flows from the electrode to the mud. The system avoids errors due to undesirable interactions between the mud and the reference electrode materials. (author).

  5. Numerical modelling of the flow in the resin infusion process on the REV scale: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Jabbari, M.; Spangenberg, J.; Hattel, J. H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark); Jambhekar, V. A.; Helmig, R. [Department of Hydromechanics and Modelling of Hydrosystems, Institute for Modelling Hydraulic and Environmental Systems, Universität Stuttgart, Stuttgart (Germany); Gersborg, A. R. [SCION DTU, Diplomvej 373N, DK-2800 Lyngby (Denmark)

    2016-06-08

    The resin infusion process (RIP) has developed as a low cost method for manufacturing large fibre reinforced plastic parts. However, the process still presents some challenges to industry with regards to reliability and repeatability, resulting in expensive and inefficient trial and error development. In this paper, we show the implementation of 2D numerical models for the RIP using the open source simulator DuMu{sup X}. The idea of this study is to present a model which accounts for the interfacial forces coming from the capillary pressure on the so-called representative elementary volume (REV) scale. The model is described in detail and three different test cases — a constant and a tensorial permeability as well as a preform/Balsa domain — are investigated. The results show that the developed model is very applicable for the RIP for manufacturing of composite parts. The idea behind this study is to test the developed model for later use in a real application, in which the preform medium has numerous layers with different material properties.

  6. Plastic casting resin poisoning

    Science.gov (United States)

    Epoxy poisoning; Resin poisoning ... Epoxy and resin can be poisonous if they are swallowed or their fumes are breathed in. ... Plastic casting resins are found in various plastic casting resin products.

  7. Monitoring catalyst flow rate in a FCC cold pilot unity by gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Brito, Marcio F.P.; Netto, Wilson F.S.; Miranda, Marcia V.F.E.S.; Junior, Isacc A.S.; Dantas, Carlos C.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    A model for monitoring catalyst mass flow in riser of Fluid Catalytic Cracking - FCC, pilot unity as a function of air flow and solid injection is proposed. The fluidized FCC- catalyst bed system is investigated in an experimental setup the Cold Pilot Unity - CPU by means of gamma ray transmission measurements. Riser in CPU simulates the reactor in FCC process. By automation control air flow is instrumentally measured in riser and the solid injection is manually controlled by valve adjusting. Keeping a constant solid injection, catalyst level at the return column was measured by gamma transmission for several air flow values in riser. The operational condition reached a steady state regime before given to setup a new air flow value. A calibration of catalyst level as a function of air flow in riser is calculated, therefore, a model for solid feed rate is derived. Recent published work evaluates solid concentration in riser of the CPU by means of gamma ray transmission, and a correlation with air velocity is obtained. In this work, the model for solid feed rate was further investigated by carrying out experiments to measure catalyst concentration at the same air flow values. These experiments lead to a model for monitoring catalyst flow in riser as function of solid feed rate and air flow. Simulation with random numbers produced with Matlab software allows to define validation criteria for the model parameters. (author)

  8. Instrumentation to Monitor Transient Developing Periodic Flow in Newtonian Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Bamberger, Judith A.; Enderlin, Carl W.

    2014-08-03

    This paper describes measurement techniques developed and applied to characterize solids mobilization and mixing of Newtonian slurries that are subjected to transient, periodic, developing flows. Metrics to characterize mobilization and mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed (used to determine mobilization) and the concentration within the cloud as a function of elevation [C(Z)]. A second method, continuous sample extraction, characterization, and reinsertion was successfully used to measure average density and characterize the concentration within the cloud. Testing focused on mixing vessels using intermitent jet mixers oriented vertically downward. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents, and to determine mixing times for process evaluation.

  9. Measurement system of bubbly flow using Ultrasonic Velocity Profile Monitor and Video Data Processing Unit. 3. Comparison of flow characteristics between bubbly cocurrent and countercurrent flows

    International Nuclear Information System (INIS)

    Zhou, Shirong; Suzuki, Yumiko; Aritomi, Masanori; Matsuzaki, Mitsuo; Takeda, Yasushi; Mori, Michitsugu

    1998-01-01

    The authors have developed a new measurement system which consisted of an Ultrasonic Velocity Profile Monitor (UVP) and a Video Data Processing Unit (VDP) in order to clarify the two-dimensional flow characteristics in bubbly flows and to offer a data base to validate numerical codes for two-dimensional two-phase flow. In the present paper, the proposed measurement system is applied to fully developed bubbly cocurrent flows in a vertical rectangular channel. At first, both bubble and water velocity profiles and void fraction profiles in the channel were investigated statistically. In addition, the two-phase multiplier profile of turbulence intensity, which was defined as a ratio of the standard deviation of velocity fluctuation in a bubbly flow to that in a water single phase flow, were examined. Next, these flow characteristics were compared with those in bubbly countercurrent flows reported in our previous paper. Finally, concerning the drift flux model, the distribution parameter and drift velocity were obtained directly from both bubble and water velocity profiles and void fraction profiles, and their results were compared with those in bubbly countercurrent flows. (author)

  10. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit. 2. Flow characteristics of bubbly countercurrent flow

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu.

    1997-01-01

    The authors have developed a measurement system which is composed of an ultrasonic velocity profile monitor and a video data processing unit in order to clarify its multi-dimensional flow characteristics in bubbly flows and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system was applied for bubbly countercurrent flows in a vertical rectangular channel. At first, both bubble and water velocity profiles and void fraction profiles in the channel were investigated statistically. Next, turbulence intensity in a continuous liquid phase was defined as a standard deviation of velocity fluctuation, and the two-phase multiplier profile of turbulence intensity in the channel was clarified as a ratio of the standard deviation of flow fluctuation in a bubbly countercurrent flow to that in a water single phase flow. Finally, the distribution parameter and drift velocity used in the drift flux model for bubbly countercurrent flows were calculated from the obtained velocity profiles of both phases and void fraction profile, and were compared with the correlation proposed for bubbly countercurrent flows. (author)

  11. Resin composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Peutzfeldt, Anne; Lussi, Adrian

    2014-01-01

    OBJECTIVE: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity...... of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p....008). CONCLUSIONS: The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE: The results from this study suggest that the marginal quality of restorations can...

  12. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu; Yoshioka, Yuzuru.

    1996-01-01

    The authors have been developing a measurement system for bubbly flow in order to clarify its multi-dimensional flow characteristics and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system combining an ultrasonic velocity profile monitor with a video data processing unit is proposed, which can measure simultaneously velocity profiles in both gas and liquid phases, a void fraction profile for bubbly flow in a channel, and an average bubble diameter and void fraction. Furthermore, the proposed measurement system is applied to measure flow characteristics of a bubbly countercurrent flow in a vertical rectangular channel to verify its capability. (author)

  13. Polycyclic Aromatic Hydrocarbons (PAHs) and Hopanes in Plastic Resin Pellets as Markers of Oil Pollution via International Pellet Watch Monitoring.

    Science.gov (United States)

    Yeo, Bee Geok; Takada, Hideshige; Hosoda, Junki; Kondo, Atsuko; Yamashita, Rei; Saha, Mahua; Maes, Thomas

    2017-08-01

    Oil pollution in the marine environment is an unavoidable problem due to chronic input from local sources, particularly in urban areas and oil spills. Oil pollution not only causes immediate physical damages to surrounding wildlife but also some components, including higher molecular weight PAHs, can persist in the environment for many years and pose insidious threats to the ecosystem. Long-term and nontargeted monitoring of oil pollution is important. This paper examines the ability of International Pellet Watch (IPW) for initial identification and monitoring of oil pollution by analysing PAHs and hopanes in plastic pellet samples collected globally by volunteers. PAH concentrations with the sum of 28 parent and methyl PAHs vary geographically, ranging from 0.035 to 24.4 µg/g-pellet, in line with the presence or absence of local oil pollution sources, such as oil refineries or oil spill sites. This suggests that PAHs can be used to monitor petroleum pollution in IPW. A colour-coded categorization for PAH concentrations within IPW monitoring also is established to facilitate data presentation and understanding. PAH concentrations are generally higher in Western Europe, especially around the North Sea shorelines, moderate in East Asia and North America, and lower in South East Asia, Oceania, South America, and Africa. Hopane concentrations, with a smaller spatial variation (1.7-101 µg/g-pellet), showed no spatial pattern. This result and the poor correlation between hopanes and PAHs suggest that hopane concentrations alone are unsuited to identify petroleum pollution. However, hopane compositions can be used for fingerprinting sources of oil pollution. Thus, both PAHs and hopanes in IPW allow for low cost, remote monitoring of global oil pollution.

  14. Ponderosa pine resin defenses and growth: metrics matter.

    Science.gov (United States)

    Hood, Sharon; Sala, Anna

    2015-11-01

    Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow

  15. Anti-Corruption Measures: Persistent Problems Exist in Monitoring Bulk Cash Flows at Kabul International Airport

    Science.gov (United States)

    2012-12-11

    SIGAR SP-13-1 Anti- Corruption / Currency Movement at KBL Special Inspector General for Afghanistan Reconstruction SIGAR ANTI... CORRUPTION MEASURES: PERSISTENT PROBLEMS EXIST IN MONITORING BULK CASH FLOWS AT KABUL INTERNATIONAL AIRPORT This product was completed under SIGAR’s...REPORT TYPE 3. DATES COVERED 00-00-2012 to 00-00-2012 4. TITLE AND SUBTITLE Anti- Corruption Measures: Persistent Problems Exist in Monitoring Bulk

  16. Research on Segmentation Monitoring Control of IA-RWA Algorithm with Probe Flow

    Science.gov (United States)

    Ren, Danping; Guo, Kun; Yao, Qiuyan; Zhao, Jijun

    2018-04-01

    The impairment-aware routing and wavelength assignment algorithm with probe flow (P-IA-RWA) can make an accurate estimation for the transmission quality of the link when the connection request comes. But it also causes some problems. The probe flow data introduced in the P-IA-RWA algorithm can result in the competition for wavelength resources. In order to reduce the competition and the blocking probability of the network, a new P-IA-RWA algorithm with segmentation monitoring-control mechanism (SMC-P-IA-RWA) is proposed. The algorithm would reduce the holding time of network resources for the probe flow. It segments the candidate path suitably for the data transmitting. And the transmission quality of the probe flow sent by the source node will be monitored in the endpoint of each segment. The transmission quality of data can also be monitored, so as to make the appropriate treatment to avoid the unnecessary probe flow. The simulation results show that the proposed SMC-P-IA-RWA algorithm can effectively reduce the blocking probability. It brings a better solution to the competition for resources between the probe flow and the main data to be transferred. And it is more suitable for scheduling control in the large-scale network.

  17. System-focused environmental flow regime prescription, monitoring and adaptive management

    Science.gov (United States)

    Hetherington, David; Lexartza Artza, Irantzu

    2016-04-01

    that more peripheral influencing factors should be given serious consideration when developing environmental flow regimes. These factors could include the development of ice, non-fluvial geomorphic processes such as landslides, connectivity with groundwater and provision for local cottage industries. Even with a thorough appreciation of the holistic system, the value of detailed environmental monitoring and adaptive management plans cannot be underestimated as a means of further managing risk and uncertainty in complex systems. It is suggested that by taking a more holistic and system-focused approach to environmental flow definition, that environmental flow regimes can be tailored to the specificity and complexity of any given location. By improving the way that environmental flow regimes and associated physical mitigation are prescribed, monitored and managed it should be possible to develop more sustainable forms of energy production whilst minimising environmental harm as far as possible.

  18. Debris flow monitoring in the Acquabona watershed on the Dolomites (Italian Alps)

    Science.gov (United States)

    Berti, M.; Genevois, R.; LaHusen, R.; Simoni, A.; Tecca, P.R.

    2000-01-01

    In 1997 a field monitoring system was installed in Acquabona Creek in the Dolomites (Eastern Italian Alps) to observe the hydrologic conditions for debris flow occurrence and some dynamic properties of debris flow. The monitoring system consists of three remote stations: an upper one located at the head of a deeply-incised channel and two others located downstream. The system is equipped with sensors for measuring rainfall, pore pressures in the mobile channel bottom, ground vibrations, debris flow depth, total normal stress and fluid pore-pressure at the base of the flow. Two video cameras record events at the upper channel station and one video is installed at the lowermost station. During summer 1998, three debris flows (volumes from less than 1000 m3 up to 9000 m3) occurred at Acquabona. The following results were obtained from a preliminary analysis of the data: 1) All of the flows were triggered by rainfalls of less than 1 hour duration, with peak rainfall intensities ranging from 4.8 to 14.7 mm / 10 minute. 2) Debris flows initiated in several reaches of the channel, including the head of the talus slope. 3) The initial surges of the mature flows had a higher solid concentration and a lower velocity (up to 4 m/s) than succeeding, more dilute surges (more than 7 m/s). 4) Total normal stress and pore fluid pressures measured at the base of the flow (mean depth about 1.1 m) were similar (about 15 kPa), indicating a completely liquefied flow. 5) Peak flows entrained debris at a rate of about 6 m3/m of channel length and channel bed scouring was proportional to the local slope gradient and was still evident in the lower channel where the slope was 7??. ?? 2000 Elsevier Science Ltd. All rights reserved.

  19. Flow injection on-line spectrophotometric determination of thorium(IV) after preconcentration on XAD-4 resin impregnated with oxytetracycline

    Energy Technology Data Exchange (ETDEWEB)

    Shahida, Shabnam; Khan, Muhammad Haleem [Univ. of Azad Jammu and Kashmir, Muzaffarabad (Pakistan). Dept. of Chemistry; Ali, Akbar [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.

    2014-02-15

    A very sensitive, selective and simple flow injection time-based method was developed for on-line preconcentration and determination of thorium(IV) at micro g L{sup -1} levels in environmental samples. The system operation was based on thorium(IV) ion retention at pH 4.0 in the minicolumn at a flow rate of 15.2 mL min{sup -1}. The trapped complex was then eluted with 3.6 mol L{sup -1} HCl at a flow rate of 4.9 mL min{sup -1}. The amount of thorium(IV) in the eluate was measured spectrophotometrically at 651 nm using arsenazo-III solution (0.05 % in 3.6 mol L{sup -1} HCl stabilized with 1 % triton X-100, 4.9 mL min{sup -1}) as colorimetric reagent. All chemical, and flow injection variables were optimized for the quantitative preconcentration of metal and a study of interference level of various ions was also carried out. The system offered low backpressure and improved sensitivity and selectivity. At a preconcentration time of 60 s and a sample frequency of 40 h{sup -1}, the enhancement factor was 97, the detection limit was 0.25 μg L{sup -1}, and the precision expressed as relative standard deviation was 1.08 % (at 50 μg L{sup -1}), whereas for 300 s of the preconcentration time and a sample frequency of 10 h{sup -1}, the enhancement factor of 357, the detection limit (3s) of 0.069 μg L{sup -1} and the precision of 1.32 % (at 10 μg L{sup -1}) was reported. The accuracy of the developed method was sufficient and evaluated by the analysis of certified reference material IAEA-SL-1 (Lake Sediment) and spiked water samples.

  20. Diagnosis of Plasma Cell Dyscrasias and Monitoring of Minimal Residual Disease by Multiparametric Flow Cytometry

    Science.gov (United States)

    Soh, Kah Teong; Tario, Joseph D.; Wallace, Paul K.

    2018-01-01

    Synopsis Plasma cell dyscrasia (PCD) is a heterogeneous disease which has seen a tremendous change in outcomes due to improved therapies. Over the last few decades, multiparametric flow cytometry has played an important role in the detection and monitoring of PCDs. Flow cytometry is a high sensitivity assay for early detection of minimal residual disease (MRD) that correlates well with progression-free survival and overall survival. Before flow cytometry can be effectively implemented in the clinical setting sample preparation, panel configuration, analysis, and gating strategies must be optimized to ensure accurate results. Current consensus methods and reporting guidelines for MRD testing are discussed. PMID:29128071

  1. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    Science.gov (United States)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  2. Measurement of bubbly flows in vertical channels using ultrasonic velocity profile monitor

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou Shirong; Takeda, Yasushi; Nakamura, Hideo; Kukita, Yutaka

    1998-01-01

    The authors have been developing measurement technique, using the Ultrasonic Doppler effect and applicable for a bubbly flow in vertical channels in order to understand their multi-dimensional flow characteristics and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. Our developed measurement system is composed of an ultrasonic velocity profile monitor with a video data processing unit, which can measure simultaneously velocity profiles in both gas and liquid phases, a void fraction profile for bubbly flow in a channel, and an average bubble diameter and void fraction. In this paper, our proposed measurement system was applied to bubbly countercurrent flows in a vertical rectangular channel the followings are discussed: (1) the measurement principle, (2) the data processing process, (3) measurement accuracy and (4) further problems. (author)

  3. Satellite-driven modeling approach for monitoring lava flow hazards during the 2017 Etna eruption

    Science.gov (United States)

    Del Negro, C.; Bilotta, G.; Cappello, A.; Ganci, G.; Herault, A.; Zago, V.

    2017-12-01

    The integration of satellite data and modeling represents an efficient strategy that may provide immediate answers to the main issues raised at the onset of a new effusive eruption. Satellite-based thermal remote sensing of hotspots related to effusive activity can effectively provide a variety of products suited to timing, locating, and tracking the radiant character of lava flows. Hotspots show the location and occurrence of eruptive events (vents). Discharge rate estimates may indicate the current intensity (effusion rate) and potential magnitude (volume). High-spatial resolution multispectral satellite data can complement field observations for monitoring the front position (length) and extension of flows (area). Physics-based models driven, or validated, by satellite-derived parameters are now capable of fast and accurate forecast of lava flow inundation scenarios (hazard). Here, we demonstrate the potential of the integrated application of satellite remote-sensing techniques and lava flow models during the 2017 effusive eruption at Mount Etna in Italy. This combined approach provided insights into lava flow field evolution by supplying detailed views of flow field construction (e.g., the opening of ephemeral vents) that were useful for more accurate and reliable forecasts of eruptive activity. Moreover, we gave a detailed chronology of the lava flow activity based on field observations and satellite images, assessed the potential extent of impacted areas, mapped the evolution of lava flow field, and executed hazard projections. The underside of this combination is the high sensitivity of lava flow inundation scenarios to uncertainties in vent location, discharge rate, and other parameters, which can make interpreting hazard forecasts difficult during an effusive crisis. However, such integration at last makes timely forecasts of lava flow hazards during effusive crises possible at the great majority of volcanoes for which no monitoring exists.

  4. A multichannel bioimpedance monitor for full-body blood flow monitoring

    Czech Academy of Sciences Publication Activity Database

    Vondra, Vlastimil; Jurák, Pavel; Viščor, Ivo; Halámek, Josef; Leinveber, P.; Matějková, M.; Soukup, L.

    2016-01-01

    Roč. 61, č. 1 (2016), s. 107-118 ISSN 0013-5585 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA ČR GAP102/12/2034 Institutional support: RVO:68081731 Keywords : bioimpedance * blood flow * cardiac output * multichannel measurement * non- invasive measurements * pulse wave velocity Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 0.915, year: 2016

  5. Real time EM waves monitoring system for oil industry three phase flow measurement

    International Nuclear Information System (INIS)

    Al-Hajeri, S; Wylie, S R; Shaw, A; Al-Shamma'a, A I

    2009-01-01

    Monitoring fluid flow in a dynamic pipeline is a significant problem in the oil industry. In order to manage oil field wells efficiently, the oil industry requires accurate on line sensors to monitor the oil, gas, and water flow in the production pipelines. This paper describes a non-intrusive sensor that is based on an EM Waves cavity resonator. It determines and monitors the percentage volumes of each phase of three phase (oil, gas, and water) in the pipeline, using the resonant frequencies shifts that occur within an electromagnetic cavity resonator. A laboratory prototype version of the sensor system was constructed, and the experimental results were compared to the simulation results which were obtained by the use of High Frequency Structure Simulation (HFSS) software package.

  6. PREPARATION, CHARACTERIZATION AND THERMAL BEHAVIOR OF ALKYL SUBSTITUTED PHENOLIC EPOXY RESIN

    OpenAIRE

    Jyoti Chaudhary*, Supriya Dadhich, Giriraj Tailor

    2017-01-01

    The present article deals with the synthesis of phenolic epoxy resin by the reaction of phenolic resin and epichlorohydrin. The synthesis of phenolic resin was carried out by using p-ethylphenol, formaldehyde and naphthol. The structures of phenolic and epoxy resins were confirmed by spectroscopic analysis. The synthesized epoxy resin showed solubility in polar solvents like DMF, dioxane, acetone, DMSO, THF, ethyl acetate, and chloroform. Thermal characterization of epoxy resin was monitored ...

  7. Mass flow and particle size monitoring of pulverised fuel vertical spindle mills

    Directory of Open Access Journals (Sweden)

    Archary Hamresin

    2016-06-01

    Full Text Available The first step towards condition based maintenance of the milling plant is the implementation of online condition monitoring of the mill. The following paper presents and analyses methods of monitoring the key performance factors of a vertical spindle mill that is suited for implementation on older power stations, i.e. the quantity (mass flow rate and quality (particle fineness of the pulverised fuel produced by the mill. It is shown herein that the mill throughput can be monitored on-line using a simple mill energy balance that successfully predicts the coal throughput within 2.33% as compared to a calibrated coal feeder. A sensitivity analysis reveals that the coal moisture is a critical measurement for this method to be adopted as an on-line mass flow monitoring tool. A laser based particle size analyser tool was tested for use in the power plant environment as an online monitoring solution to measure pulverised fuel fineness. It was revealed that several factors around the set-up and operation of the instrument have an influence on the perceived results. Although the instrument showed good precision and repeatability of results, these factors must be taken into account in order to improve the accuracy of the reported results before the instrument can be commissioned as an on-line monitoring solution.

  8. Longitudinal optical monitoring of blood flow in breast tumors during neoadjuvant chemotherapy

    Science.gov (United States)

    Cochran, J. M.; Chung, S. H.; Leproux, A.; Baker, W. B.; Busch, D. R.; DeMichele, A. M.; Tchou, J.; Tromberg, B. J.; Yodh, A. G.

    2017-06-01

    We measure tissue blood flow markers in breast tumors during neoadjuvant chemotherapy and investigate their correlation to pathologic complete response in a pilot longitudinal patient study (n  =  4). Tumor blood flow is quantified optically by diffuse correlation spectroscopy (DCS), and tissue optical properties, blood oxygen saturation, and total hemoglobin concentration are derived from concurrent diffuse optical spectroscopic imaging (DOSI). The study represents the first longitudinal DCS measurement of neoadjuvant chemotherapy in humans over the entire course of treatment; it therefore offers a first correlation between DCS flow indices and pathologic complete response. The use of absolute optical properties measured by DOSI facilitates significant improvement of DCS blood flow calculation, which typically assumes optical properties based on literature values. Additionally, the combination of the DCS blood flow index and the tissue oxygen saturation from DOSI permits investigation of tissue oxygen metabolism. Pilot results from four patients suggest that lower blood flow in the lesion-bearing breast is correlated with pathologic complete response. Both absolute lesion blood flow and lesion flow relative to the contralateral breast exhibit potential for characterization of pathological response. This initial demonstration of the combined optical approach for chemotherapy monitoring provides incentive for more comprehensive studies in the future and can help power those investigations.

  9. Electrical resistance tomography to monitor unsaturated moisture flow in cementitious materials

    Energy Technology Data Exchange (ETDEWEB)

    Hallaji, Milad [Department of Civil Construction and Environmental Engineering, North Carolina State University, Raleigh, NC 27695 (United States); Seppänen, Aku [Department of Applied Physics, University of Eastern Finland, Kuopio (Finland); Pour-Ghaz, Mohammad, E-mail: mpourghaz@ncsu.edu [Department of Civil Construction and Environmental Engineering, North Carolina State University, Raleigh, NC 27695 (United States)

    2015-03-15

    Traditionally the electrically-based assessment of the moisture flow in cement-based materials relies on two- or four-point measurements. In this paper, imaging of moisture distribution with electrical resistance tomography (ERT) is considered. Especially, the aim is to study whether ERT could give information on unsaturated moisture flows in cases where the flow is non-uniform. In the experiment, the specimens are monitored with ERT during the water ingress. The ERT reconstructions are compared with neutron radiographs, which provide high resolution information on the 2D distribution of the moisture. The results indicate that ERT is able to detect the moisture movement and to show approximately the shape and position of the water front even if the flow is nonuniform.

  10. Developing an Integrated Monitoring and Evaluation Flow for Sustainable Investment Projects

    Directory of Open Access Journals (Sweden)

    Florin TACHE

    2011-12-01

    Full Text Available Under the circumstances of certain weaknesses in the monitoring and evaluation processes of sustainable investment projects, the paper aims to develop a general integrated flow, encompassing both a project monitoring system and also a project evaluation system for the investment projects involving economic objectives, as well as cross-cutting social and environmental targets. The whole approach is being presented as a flowchart, which highlights the intimate relationship between the monitoring and evaluation processes, and provides a formal framework for performing a logical monitoring and evaluation process, taking into account simultaneously the economic, social and environmental perspectives, within an investment project. Last, but not least, the article states both the estimated advantages and the disadvantages of such a managerial tool, opening new perspectives for developing further improved models and systems.

  11. Implementation of the Fissile Mass Flow Monitor Source Verification and Confirmation

    International Nuclear Information System (INIS)

    Uckan, Taner; March-Leuba, Jose A.; Powell, Danny H.; Nelson, Dennis; Radev, Radoslav

    2007-01-01

    This report presents the verification procedure for neutron sources installed in U.S. Department of Energy equipment used to measure fissile material flow. The Fissile Mass Flow Monitor (FMFM) equipment determines the 235 U fissile mass flow of UF 6 gas streams by using 252 Cf neutron sources for fission activation of the UF 6 gas and by measuring the fission products in the flow. The 252 Cf sources in each FMFM are typically replaced every 2 to 3 years due to their relatively short half-life (∼ 2.65 years). During installation of the new FMFM sources, the source identity and neutronic characteristics provided by the manufacturer are verified with the following equipment: (1) a remote-control video television (RCTV) camera monitoring system is used to confirm the source identity, and (2) a neutron detection system (NDS) is used for source-strength confirmation. Use of the RCTV and NDS permits remote monitoring of the source replacement process and eliminates unnecessary radiation exposure. The RCTV, NDS, and the confirmation process are described in detail in this report.

  12. Persistent organic pollutants monitoring in marine coastal environment using beached plastic resin pellets and effective risk communication via International Pellet Watch (IPW) as a tool.

    Science.gov (United States)

    Yeo, B. G. M.; Takada, H.; Hosoda, J.

    2014-12-01

    International Pellet Watch (IPW) is an ongoing global monitoring of persistent organic pollutants (POPs) using preproduction plastic resin pellets. These pellets are easily collected and transported allowing the general public worldwide to get involved. Thus, risk communication toward the pellet collectors is a significant part of IPW to ensure continuous effort and interest. The pellet samples were analyzed for polychlorinated biphenyl (PCBs), dichlorodiphenyltrichloroethane and degradation products (DDTs), and hexachlorocyclohexanes (HCHs). Additional pollutants such as polycyclic aromatic hydrocarbons (PAHs) and Hopanes were also analyzed for some samples. Analytical results showed distinct patterns with high concentrations (Pesticide DDTs instead were found to be higher in developing countries such as Brazil and Vietnam (> 500ng/g-pellet). These countries may still be using DDTs as a vector control mostly to combat malaria. High concentrations of DDTs were also found in Greece, China and Australia (> 100ng/g-pellet) suggesting the possibility of illegal usage as pesticide or anti fouling paint. HCHs concentrations were mostly low due to its low retention in the environment. However, high HCHs concentrations were mostly found in the southern hemisphere. Very high concentration of PAHs in pellet samples can be utilized for early identification of recent oil pollution. High PAHs concentration in Tauranga, New Zealand was found to be caused by local oil spill. Hopanes in pellets can be used for source identification of oil pollution. Global mapping and comparison among IPW data can be used to provide better explanations to IPW volunteers by sorting concentrations into pollution categories. Communication reports are tailor written based on the volunteers familiarity to IPW's issues, educational background, occupation and their potential to further spread awareness. Based on feedbacks, the volunteers were grateful to receive reports of their samples felt personally

  13. Monitoring the Erosion of Hydrolytically-Degradable Nanogels via Multiangle Light Scattering Coupled to Asymmetrical Flow Field-Flow Fractionation

    Science.gov (United States)

    Smith, Michael H.; South, Antoinette B.; Gaulding, Jeffrey C.; Lyon, L. Andrew

    2009-01-01

    We describe the synthesis and characterization of degradable nanogels that display bulk erosion under physiologic conditions (pH = 7.4, 37 °C). Erodible poly(N-isopropylmethacrylamide) nanogels were synthesized by copolymerization with N,O-(dimethacryloyl)hydroxylamine, a cross-linker previously used in the preparation of non-toxic and biodegradable bulk hydrogels. To monitor particle degradation, we employed multiangle light scattering and differential refractometry detection following asymmetrical flow field-flow fractionation. This approach allowed the detection of changes in nanogel molar mass and topology as a function of both temperature and pH. Particle erosion was evident from both an increase in nanogel swelling and a decrease in scattering intensity as a function of time. Following these analyses, the samples were recovered for subsequent characterization by direct particle tracking, which yields hydrodynamic size measurements and enables number density determination. Additionally, we confirmed the conservation of nanogel stimuli-responsivity through turbidity measurements. Thus, we have demonstrated the synthesis of degradable nanogels that erode under conditions and on timescales that are relevant for many drug delivery applications. The combined separation and light scattering detection method is demonstrated to be a versatile means to monitor erosion and should also find applicability in the characterization of other degradable particle constructs. PMID:20000662

  14. Observing hydrological processes: recent advancements in surface flow monitoring through image analysis

    Science.gov (United States)

    Tauro, Flavia; Grimaldi, Salvatore

    2017-04-01

    Recently, several efforts have been devoted to the design and development of innovative, and often unintended, approaches for the acquisition of hydrological data. Among such pioneering techniques, this presentation reports recent advancements towards the establishment of a novel noninvasive and potentially continuous methodology based on the acquisition and analysis of images for spatially distributed observations of the kinematics of surface waters. The approach aims at enabling rapid, affordable, and accurate surface flow monitoring of natural streams. Flow monitoring is an integral part of hydrological sciences and is essential for disaster risk reduction and the comprehension of natural phenomena. However, water processes are inherently complex to observe: they are characterized by multiscale and highly heterogeneous phenomena which have traditionally demanded sophisticated and costly measurement techniques. Challenges in the implementation of such techniques have also resulted in lack of hydrological data during extreme events, in difficult-to-access environments, and at high temporal resolution. By combining low-cost yet high-resolution images and several velocimetry algorithms, noninvasive flow monitoring has been successfully conducted at highly heterogeneous scales, spanning from rills to highly turbulent streams, and medium-scale rivers, with minimal supervision by external users. Noninvasive image data acquisition has also afforded observations in high flow conditions. Latest novelties towards continuous flow monitoring at the catchment scale have entailed the development of a remote gauge-cam station on the Tiber River and integration of flow monitoring through image analysis with unmanned aerial systems (UASs) technology. The gauge-cam station and the UAS platform both afford noninvasive image acquisition and calibration through an innovative laser-based setup. Compared to traditional point-based instrumentation, images allow for generating surface

  15. Composite use of numerical groundwater flow modeling and geoinformatics techniques for monitoring Indus Basin aquifer, Pakistan.

    Science.gov (United States)

    Ahmad, Zulfiqar; Ashraf, Arshad; Fryar, Alan; Akhter, Gulraiz

    2011-02-01

    The integration of the Geographic Information System (GIS) with groundwater modeling and satellite remote sensing capabilities has provided an efficient way of analyzing and monitoring groundwater behavior and its associated land conditions. A 3-dimensional finite element model (Feflow) has been used for regional groundwater flow modeling of Upper Chaj Doab in Indus Basin, Pakistan. The approach of using GIS techniques that partially fulfill the data requirements and define the parameters of existing hydrologic models was adopted. The numerical groundwater flow model is developed to configure the groundwater equipotential surface, hydraulic head gradient, and estimation of the groundwater budget of the aquifer. GIS is used for spatial database development, integration with a remote sensing, and numerical groundwater flow modeling capabilities. The thematic layers of soils, land use, hydrology, infrastructure, and climate were developed using GIS. The Arcview GIS software is used as additive tool to develop supportive data for numerical groundwater flow modeling and integration and presentation of image processing and modeling results. The groundwater flow model was calibrated to simulate future changes in piezometric heads from the period 2006 to 2020. Different scenarios were developed to study the impact of extreme climatic conditions (drought/flood) and variable groundwater abstraction on the regional groundwater system. The model results indicated a significant response in watertable due to external influential factors. The developed model provides an effective tool for evaluating better management options for monitoring future groundwater development in the study area.

  16. Interacting Blends of Novel Unsaturated Polyester Amide Resin with Styrene

    OpenAIRE

    Patel, Hasmukh S.; Panchal, Kumar K.

    2004-01-01

    Novel unsaturated poly (ester-amide) resins (UPEAs) were prepared by the reaction between an epoxy resin, namely diglycidyl ether of bisphenol–A (DGEBA) and unsaturated aliphatic bisamic acids using a base catalyst. These UPEAs were then blended with a vinyl monomer namely, Styrene (STY.) to produce a homogeneous resin syrup. The curing of these UPEAs-STY. resin blends was carried out by using benzoyl peroxide (BPO) as a catalyst and was monitored by using a differential scanning calorimeter ...

  17. Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

    Science.gov (United States)

    Martin, Marcel Nations; Chang, Leyen S.; Jeffries, Jay B.; Hanson, Ronald K.; Nawaz, Anuscheh; Taunk, Jaswinder S.; Driver, David M.; Raiche, George

    2013-01-01

    A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

  18. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    2018-01-01

    Background Positron emission tomography (PET) imaging of anaesthetized pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the distribution of several radiotracers. However, the effect of physiological factors regulating...... and the monitoring parameters. Results No significant statistical correlations were found between CBF and the nine monitoring variables. However, we found that arterial carbon dioxide tension (PaCO2) and body temperature were important predictors of CBF that should be observed and kept constant. In addition, we...

  19. The use of a low-cost gas-liquid flow meter to monitor severe slugging

    DEFF Research Database (Denmark)

    Andreussi, Paolo; Bonizzi, Marco; Ciandri, Paolo

    2017-01-01

    method to monitor severe slugging by means of low cost instrumentation, in particular, by replacing a cumbersome instrument such as a gamma-densitometer with a differential pressure transmitter. In field operation, the multiphase orifice used in these experiments can be replaced by a calibrated control......A very simple, low-cost gas-liquid flow meter that only employs conventional field instrumentation has been used to monitor severe slugging occurring at the exit of a vertical pipe. This meter was originally developed for conventional oil field applications [1] and is based on the readings...

  20. Review: Resin Composite Filling

    OpenAIRE

    Desmond Ng; Jimmy C. M. Hsiao; Keith C. T. Tong; Harry Kim; Yanjie Mai; Keith H. S. Chan

    2010-01-01

    The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin ...

  1. Analysis of novel geometry-independent method for dialysis access pressure-flow monitoring

    Directory of Open Access Journals (Sweden)

    Panduranga Harsha

    2008-11-01

    Full Text Available Abstract Background End-stage renal disease (ESRD confers a large health-care burden for the United States, and the morbidity associated with vascular access failure has stimulated research into detection of vascular access stenosis and low flow prior to thrombosis. We present data investigating the possibility of using differential pressure (ΔP monitoring to estimate access flow (Q for dialysis access monitoring, with the goal of utilizing micro-electro-mechanical systems (MEMS pressure sensors integrated within the shaft of dialysis needles. Methods A model of the arteriovenous graft fluid circuit was used to study the relationship between Q and the ΔP between two dialysis needles placed 2.5–20.0 cm apart. Tubing was varied to simulate grafts with inner diameters of 4.76–7.95 mm. Data were compared with values from two steady-flow models. These results, and those from computational fluid dynamics (CFD modeling of ΔP as a function of needle position, were used to devise and test a method of estimating Q using ΔP and variable dialysis pump speeds (variable flow that diminishes dependence on geometric factors and fluid characteristics. Results In the fluid circuit model, ΔP increased with increasing volume flow rate and with increasing needle-separation distance. A nonlinear model closely predicts this ΔP-Q relationship (R2 > 0.98 for all graft diameters and needle-separation distances tested. CFD modeling suggested turbulent needle effects are greatest within 1 cm of the needle tip. Utilizing linear, quadratic and combined variable flow algorithms, dialysis access flow was estimated using geometry-independent models and an experimental dialysis system with the pressure sensors separated from the dialysis needle tip by distances ranging from 1 to 5 cm. Real-time ΔP waveform data were also observed during the mock dialysis treatment, which may be useful in detecting low or reversed flow within the access. Conclusion With further

  2. Analysis of novel geometry-independent method for dialysis access pressure-flow monitoring.

    Science.gov (United States)

    Weitzel, William F; Cotant, Casey L; Wen, Zhijie; Biswas, Rohan; Patel, Prashant; Panduranga, Harsha; Gianchandani, Yogesh B; Rubin, Jonathan M

    2008-11-05

    End-stage renal disease (ESRD) confers a large health-care burden for the United States, and the morbidity associated with vascular access failure has stimulated research into detection of vascular access stenosis and low flow prior to thrombosis. We present data investigating the possibility of using differential pressure (DeltaP) monitoring to estimate access flow (Q) for dialysis access monitoring, with the goal of utilizing micro-electro-mechanical systems (MEMS) pressure sensors integrated within the shaft of dialysis needles. A model of the arteriovenous graft fluid circuit was used to study the relationship between Q and the DeltaP between two dialysis needles placed 2.5-20.0 cm apart. Tubing was varied to simulate grafts with inner diameters of 4.76-7.95 mm. Data were compared with values from two steady-flow models. These results, and those from computational fluid dynamics (CFD) modeling of DeltaP as a function of needle position, were used to devise and test a method of estimating Q using DeltaP and variable dialysis pump speeds (variable flow) that diminishes dependence on geometric factors and fluid characteristics. In the fluid circuit model, DeltaP increased with increasing volume flow rate and with increasing needle-separation distance. A nonlinear model closely predicts this DeltaP-Q relationship (R2 > 0.98) for all graft diameters and needle-separation distances tested. CFD modeling suggested turbulent needle effects are greatest within 1 cm of the needle tip. Utilizing linear, quadratic and combined variable flow algorithms, dialysis access flow was estimated using geometry-independent models and an experimental dialysis system with the pressure sensors separated from the dialysis needle tip by distances ranging from 1 to 5 cm. Real-time DeltaP waveform data were also observed during the mock dialysis treatment, which may be useful in detecting low or reversed flow within the access. With further experimentation and needle design, this geometry

  3. Resin Characterization

    Science.gov (United States)

    2015-06-01

    to see plastic deformation of the surface. 8.1.4.3 Density: Density using the Archimedes principle (ASTM D 792). 8.1.4.4 Density as a Function of...the cure and postcure, quickly cool the sample to 0 °C or lower the temperature to quench the reaction, and then ramp the temperature at 5 °C/min to...prepared by pouring 10 g of resin into a 30-mL screw-cap scintillation vial and adding appropriate amounts of initiator, catalyst, and inhibitor

  4. Monitoring and Evaluation of Environmental Flow Prescriptions for Five Demonstration Sites of the Sustainable Rivers Project

    Science.gov (United States)

    Konrad, Christopher P.

    2010-01-01

    The Nature Conservancy has been working with U.S. Army Corps of Engineers (Corps) through the Sustainable Rivers Project (SRP) to modify operations of dams to achieve ecological objectives in addition to meeting the authorized purposes of the dams. Modifications to dam operations are specified in terms of environmental flow prescriptions that quantify the magnitude, duration, frequency, and seasonal timing of releases to achieve specific ecological outcomes. Outcomes of environmental flow prescriptions implemented from 2002 to 2008 have been monitored and evaluated at demonstration sites in five rivers: Green River, Kentucky; Savannah River, Georgia/South Carolina; Bill Williams River, Arizona; Big Cypress Creek, Texas; and Middle Fork Willamette River, Oregon. Monitoring and evaluation have been accomplished through collaborative partnerships of federal and state agencies, universities, and nongovernmental organizations.

  5. A laser Doppler catheter for monitoring both phasic and mean coronary vein flow.

    Science.gov (United States)

    Mito, K; Ogasawara, Y; Hiramatsu, O; Tsujioka, K; Kajiya, F

    1990-01-01

    A new catheter-type laser Doppler velocimeter has been developed to monitor coronary vein flow. A thin graded-index multimode optical fiber (outer diameter of 125 microns) is set inside a 5-F catheter, and eight elastic silicon rubber spikes are arranged radially toward the vessel wall to fix the catheter tip in or near the axial region of the coronary vein. He-Ne laser light (wave length = 632.8nm) is introduced into the blood through the optical fiber, and reflected light is collected by the same fiber. The Doppler signal is detected by a spectrum analyzer. To avoid any effect by the spikes on flow, the fiber is extended from the catheter tip by 3 mm at the time of measurement. Straight and curved tubing was used to examine the accuracy of flow measurement. The flow velocities recorded by the catheter, which were measured by an electromagnetic flowmeter, exhibited excellent linearity (r = straight; 0.982, curved: 0.996). The blood flow velocity in the great cardiac vein was measured by this method in five dogs. The predominantly systolic waveform, which is a characteristic of the coronary vein flow, was observed in all of the dogs. The great cardiac vein velocity increased around the beginning of the ventricular ejection and decreased gradually after the peak formation at mid- or end-diastole. In addition to this main peak, small flow components were frequently observed during isovolumic contraction and the atrial contraction phase, although these flow components varied in individual dogs. Following left anterior descending artery occlusion, the great cardiac vein flow velocity decreased significantly.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Miniaturized Water Flow and Level Monitoring System for Flood Disaster Early Warning

    Science.gov (United States)

    Ifedapo Abdullahi, Salami; Hadi Habaebi, Mohamed; Surya Gunawan, Teddy; Rafiqul Islam, MD

    2017-11-01

    This study presents the performance of a prototype miniaturised water flow and water level monitoring sensor designed towards supporting flood disaster early warning systems. The design involved selection of sensors, coding to control the system mechanism, and automatic data logging and storage. During the design phase, the apparatus was constructed where all the components were assembled using locally sourced items. Subsequently, under controlled laboratory environment, the system was tested by running water through the inlet during which the flow rate and rising water levels are automatically recorded and stored in a database via Microsoft Excel using Coolterm software. The system is simulated such that the water level readings measured in centimeters is output in meters using a multiplicative of 10. A total number of 80 readings were analyzed to evaluate the performance of the system. The result shows that the system is sensitive to water level rise and yielded accurate measurement of water level. But, the flow rate fluctuates due to the manual water supply that produced inconsistent flow. It was also observed that the flow sensor has a duty cycle of 50% of operating time under normal condition which implies that the performance of the flow sensor is optimal.

  7. Mathematical modeling of flow-injection techniques and their applications for environmental monitoring

    International Nuclear Information System (INIS)

    Begum, N.N.; Ahmed, J.

    2006-01-01

    A classification of the existing mathematical models of flow-injection (FI) manifolds based on the main principles on which they are built, have been proposed. Numerous mathematical models of FI systems employing ideas from different scientific areas (e.g. mathematical statistics, chemical engineering, chromatography) have been developed so far. The models have been compared with respect to their predictive power, the complexity of their mathematical treatment, and the requirements for computation time when applied to single-line, multi-channel and conjugated two-line FI systems. It is concluded that the axially dispersed plug flow model deserves special attention because it offers an acceptable compromise between the conflicting requirements for maximal possible mathematical simplicity and maximal possible precision. Applicability of these existing flow-injection models to single-line, multi-channel and conjugated two-line systems for environmental monitoring have been discussed. (author)

  8. Dielectrophoresis microsystem with integrated flow cytometers for on-line monitoring of sorting efficiency

    DEFF Research Database (Denmark)

    Wang, Zhenyu; Hansen, Ole; Petersen, Peter Kalsen

    2006-01-01

    Dielectrophoresis (DEP) and flow cytometry are powerful technologies and widely applied in microfluidic systems for handling and measuring cells and particles. Here, we present a novel microchip with a DEP selective filter integrated with two microchip flow cytometers (FCs) for on-line monitoring...... of cell sorting processes. On the microchip, the DEP filter is integrated in a microfluidic channel network to sort yeast cells by positive DER The two FCs detection windows are set upstream and downstream of the DEP filter. When a cell passes through the detection windows, the light scattered by the cell...... is measured by integrated polymer optical elements (waveguide, lens, and fiber coupler). By comparing the cell counting rates measured by the two FCs, the collection efficiency of the DEP filter can be determined. The chips were used for quantitative determination of the effect of flow rate, applied voltage...

  9. Risk Exposure and Net Flow in Investment Funds: Do Shareholders Monitor Asset Allocation?

    Directory of Open Access Journals (Sweden)

    Rafael Felipe Schiozer

    2014-03-01

    Full Text Available This study investigates the impact of asset allocation on the net flow of fixed income funds in the Brazilian market, by exploiting the exogenous variation in the risk perception of bank liabilities (CDs caused by the financial turmoil that followed Lehman Brothers’ demise in September 2008. The central hypothesis is that the exposure to assets negatively affected by the crisis impacts negatively the fund’s net flow. We find that, for mutual funds, the larger proportion of assets negatively affected by the crisis the larger the net outflow of resources, indicating that shareholders monitor asset allocation and exert disciplining power on fund managers by withdrawing their resources. In exclusive (fundos exclusivos, i.e., funds with a single shareholder, for which the shareholder is presumed to exert more influence on asset reallocation, we find no significant relationship between the exposure to assets negatively affected by the crisis and net flows.

  10. Non-intrusive downcomer flow measurements: a means of monitoring steam generator performance

    International Nuclear Information System (INIS)

    Taylor, C.E.; McGregor, J.E.; Kittmer, C.A.; Pettigrew, M.J.; Jelinski, E.F.; Seppala, D.A.

    1995-01-01

    Nuclear plant reliability depends directly on steam generator performance. Downcomer flow is a good monitor of steam generator performance. It provides information critical to the efficient and safe operation of steam generators as determined by the recirculation ratio and water inventory. In addition, reduced downcomer flow may indicate steam generator crudding or inadequate chemical cleaning. This paper describes the application of ultrasonic technology to measure flow velocity in the downcomer annulus during operation. The technique is non-intrusive since the measurements are taken with ultrasonic transducers mounted on the outer shell of the steam generator. Successful application of this technique required development in several areas - high temperature couplants, signal quality, transducer performance and reliability, and remote monitoring. The effects of carry under, obstacles in the downcomer annulus, temperature variation, and wall thickness are also discussed in this paper. The results of measurements from 0 to 1 00% power in the Darlington nuclear station are presented. The results are compared to thermalhydraulic calculations. A second ultrasonic technique has recently been successfully tested at operating conditions with void in the flow. This new technique is also presented in this paper. (author)

  11. Monitoring bacterial biofilms with a microfluidic flow chip designed for imaging with white-light interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Brann, Michelle; Suter, Jonathan D.; Addleman, R. Shane; Larimer, Curtis

    2017-07-01

    There is a need for imaging and sensing instrumentation that can monitor transitions in biofilm structure in order to better understand biofilm development and emergent properties such as anti-microbial resistance. Herein, we expanded on our previously reported technique for measuring and monitoring the thickness and topology of live biofilms using white-light interferometry (WLI). A flow cell designed for WLI enabled the use of this non-disruptive imaging method for the capture of high resolution three-dimensional profile images of biofilm growth over time. The fine axial resolution (3 nm) and wide field of view (>1 mm by 1 mm) enabled detection of biofilm formation as early as three hours after inoculation of the flow cell with a live bacterial culture (Pseudomonas fluorescens). WLI imaging facilitated monitoring the early stages of biofilm development and subtle variations in the structure of mature biofilms. Minimally-invasive imaging enabled monitoring of biofilm structure with surface metrology metrics (e.g., surface roughness). The system was used to observe a transition in biofilm structure that occurred in response to expsoure to a common antiseptic. In the future, WLI and the biofilm imaging cell described herein may be used to test the effectiveness of biofilm-specific therapies to combat common diseases associated with biofilm formation such as cystic fibrosis and periodontitis.

  12. Brief Communication: A low-cost Arduino®-based wire extensometer for earth flow monitoring

    Science.gov (United States)

    Guerriero, Luigi; Guerriero, Giovanni; Grelle, Gerardo; Guadagno, Francesco M.; Revellino, Paola

    2017-06-01

    Continuous monitoring of earth flow displacement is essential for the understanding of the dynamic of the process, its ongoing evolution and designing mitigation measures. Despite its importance, it is not always applied due to its expense and the need for integration with additional sensors to monitor factors controlling movement. To overcome these problems, we developed and tested a low-cost Arduino-based wire-rail extensometer integrating a data logger, a power system and multiple digital and analog inputs. The system is equipped with a high-precision position transducer that in the test configuration offers a measuring range of 1023 mm and an associated accuracy of ±1 mm, and integrates an operating temperature sensor that should allow potential thermal drift that typically affects this kind of systems to be identified and corrected. A field test, conducted at the Pietrafitta earth flow where additional monitoring systems had been installed, indicates a high reliability of the measurement and a high monitoring stability without visible thermal drift.

  13. Monitoring And Analyzing Distributed Cluster Performance And Statistics Of Atlas Job Flow

    CERN Document Server

    Ramprakash, S

    2005-01-01

    The ATLAS experiment is a High Energy Physics experiment that utilizes the services of Grid3 now migrating to the Open Science Grid (OSG). This thesis provides monitoring and analysis of performance and statistical data from individual distributed clusters that combine to form the ATLAS Grid and will ultimately be used to make scheduling decisions on this Grid. The system developed in this thesis uses a layered architecture such that predicted future developments or changes brought to the existing Grid infrastructure can easily utilize this work with minimum or no changes. The starting point of the system is based on the existing scheduling that is being done manually for ATLAS job flow. We have provided additional functionality based on the requirements of the High Energy Physics ATLAS team of physicists at UTA. The system developed in this thesis has successfully monitored and analyzed distributed cluster performance at three sites and is waiting for access to monitor data from three more sites. (Abstract s...

  14. Streamlining information flow and improving the system of indicators of socio-economic monitoring of regional development

    Directory of Open Access Journals (Sweden)

    Pakulina Alevtyna

    2016-02-01

    Full Text Available The article is devoted to the development of proposals to streamline information flows and improve the system of indicators of social-economic monitoring of regional development. The author reveals the essence of the socio-economic monitoring of the territory development. Socio-economic monitoring is considered as the factor of increasing the efficiency of economy and complex development of the territory. The proposals on optimization of the process of monitoring of the country are scientifically grounded

  15. Immobilization of spent resin with epoxy resin

    International Nuclear Information System (INIS)

    Gultom, O.; Suryanto; Sayogo; Ramdan

    1997-01-01

    immobilization of spent resin using epoxy resin has been conducted. The spent resin was mixtured with epoxy resin in variation of concentration, i.e., 30, 40, 50, 60, 70 weight percent of spent resin. The mixture were pour into the plastic tube, with a diameter of 40 mm and height of 40 mm. The density, compressive strength and leaching rate were respectively measured by quanta chrome, paul weber apparatus and gamma spectrometer. The results showed that the increasing of waste concentration would be decreased the compressive strength, and increased density by immobilized waste. The leaching rate of 137 Cs from waste product was not detected in experiment (author)

  16. On-line monitoring system development for single-phase flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Lee, Seung Gi; Ryu, Kyung Ha; Hwang, Il Soon

    2007-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover a wide area in an on-line application. We suggest an integrated approach to monitor the flow accelerated corrosion (FAC) susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible and that cover wide area, since we do not know where the FAC occurs. For this purpose, we introduce the wearing rate model which focuses on the electrochemical parameters. Using this model, we can predict the wearing rate and then compare testing results. Through analysis we identified feasibility and then developed electrochemical sensors for high temperature application; we also introduced a mechanical monitoring system which is still under development. To support the validation of the monitored results, we adopted high temperature ultrasonic transducer (UT), which shows good resolution in the testing environment. As such, all the monitored results can be compared in terms of thickness. Our validation tests demonstrated the feasibility of sensors. To support direct thickness measurement for a wide-area, the direct current potential drop (DCPD) method will be researched to integrate into the developed framework

  17. Empirical Modeling of Spatial 3D Flow Characteristics Using a Remote-Controlled ADCP System: Monitoring a Spring Flood

    Directory of Open Access Journals (Sweden)

    Claude Flener

    2015-01-01

    Full Text Available The use of acoustic Doppler current profilers (ADCP for measuring streamflow and discharge is becoming increasingly widespread. The spatial distribution of flow patterns is useful data in studying riverine habitats and geomorphology. Until now, most flow mapping has focused on measurements along a series of transects in a channel. Here, we set out to measure, model and analyze the 3D flow characteristics of a natural river over a continuous areal extent, quantifying flow velocity, 3D flow directions, volumes, water depth and their changes over time. We achieved multidimensional spatial flow measurements by deploying an ADCP on a remotely-controlled boat, combined with kinematic GNSS positioning and locally-monitored water level data. We processed this data into a 3D point cloud of accurately positioned individual 3D flow measurements that allows the visual analysis of flow velocities, directions and channel morphology in 3D space. We demonstrate how this allows monitoring changes of flow patterns with a time series of flow point clouds measured over the period of a spring flood in Finnish Lapland. Furthermore, interpolating the raw point cloud onto a 3D matrix allows us to quantify volumetric flow while reducing noise in the data. We can now quantify the volumes of water moving at certain velocities in a given reach and their location in 3D space, allowing, for instance, the monitoring of the high-velocity core and its changes over time.

  18. Potentiometric electronic tongue-flow injection analysis system for the monitoring of heavy metal biosorption processes.

    Science.gov (United States)

    Wilson, D; del Valle, M; Alegret, S; Valderrama, C; Florido, A

    2012-05-15

    An automated flow injection potentiometric (FIP) system with electronic tongue detection (ET) is used for the monitoring of biosorption processes of heavy metals on vegetable wastes. Grape stalk wastes are used as biosorbent to remove Cu(2+) ions in a fixed-bed column configuration. The ET is formed by a 5-sensor array with Cu(2+) and Ca(2+)-selective electrodes and electrodes with generic response to heavy-metals, plus an artificial neural network response model of the sensor's cross-response. The real-time monitoring of both the Cu(2+) and the cation exchanged and released (Ca(2+)) in the effluent solution is performed by using flow-injection potentiometric electronic tongue system. The coupling of the electronic tongue with automation features of the flow-injection system allows us to accurately characterize the Cu(2+) ion-biosorption process, through obtaining its breakthrough curves, and the profile of the Ca(2+) ion release. In parallel, fractions of the extract solution are analysed by spectroscopic techniques in order to validate the results obtained with the reported methodology. The sorption performance of grape stalks is also evaluated by means of well-established sorption models. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor

    Science.gov (United States)

    Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.

    2017-04-01

    Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.

  20. Monitoring dental pulp sensibility and blood flow in patients receiving mandibular orthognathic surgery.

    Science.gov (United States)

    Chen, E; Goonewardene, M; Abbott, P

    2012-03-01

    To investigate the effect of orthognathic surgery, in particular genioplasty, on pulp sensibility and pulp blood flow (PBF). Pulp blood flow monitoring and CO(2) pulp sensibility testing were performed on 101 mandibular anterior teeth from 17 subjects who received mandibular bilateral sagittal split osteotomy (BSSO) with or without genioplasty and other maxillary surgical procedures combined with orthodontic treatment. A laser Doppler flowmeter was used to monitor PBF using customized acrylic splints for each subject. Preoperative baseline scores were recorded from up to 1 week preoperatively, and subsequently monitored for up to 18-28 weeks postoperatively. The data were analysed by RMANOVA and pairwise comparisons. Statistical significance was defined as P 0.05). All teeth in both groups responded to CO(2) preoperatively. The average number of teeth that responded to CO(2) postoperatively in the genioplasty group was lower without significant difference when compared to the group without genioplasty (binomial distribution F = 2.63, P = 0.1256, normal distribution F = 2.98, P = 0.1048). At each progressive period after 1-2 weeks following surgery, the number of teeth responding to CO(2) increased significantly (P sensibility in the group without genioplasty at the end of the study. There were neither common trends nor coincidence in the recovery of PBF and pulp sensibility. © 2011 International Endodontic Journal.

  1. Monitoring the data flow of LHCb’s data acquisition system

    CERN Document Server

    Svantesson, David; Rainer, S

    2010-01-01

    The data acquisition system of the Large Hadron Collider beauty (LHCb) experiment need to read out huge amount of data. Monitoring is done for each subsystem but there exist no system to monitor the overall data flow. The aim of this work has been to design a system where the data rates can be vied continuously and making it possible to do an exact consistency check after the run to ensure no data are lost. This involves collecting and processing all necessary data from each subsystem and integrate it into the experiment control system for displaying it to the operators. The challenges are to communicate and collect data from all stages of the data acquisitions system which uses different techniques and data formats. The size of the system also makes it a challenge to gather all statistics in real time. The system must also be able to support partitioning. The result was to build a data flow monitoring system, that acquire statistics from all stages of the data acquisition, process it and display it in the ex...

  2. Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin

    Directory of Open Access Journals (Sweden)

    H. Kimura

    2011-12-01

    Full Text Available Curing reaction of bisphenol-A based benzoxazine with cyanate ester resin and the properties of the cured thermosetting resin were investigated. The cure behavior of benzoxazine with cyanate ester resin was monitored by model reaction using nuclear magnetic resonance (NMR. As a result of the model reaction, the ring opening reaction of benzoxazine ring and thermal self-cyclotrimerization of cyanate ester group occurred, and then the phenolic hydoroxyl group generated by the ring opening reaction of benzoxazine ring co-reacted with cyanate ester group. The properties of the cured thermosetting resin were estimated by mechanical properties, electrical resistivity, water resistance and heat resistance. The cured thermosetting resin from benzoxazine and cyanate ester resin showed good heat resistance, high electrical resistivity and high water resistance, compared with the cured thermosetting resin from benzoxazine and epoxy resin.

  3. Developing and validating a patient monitoring flow sheet in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Salimi, Marziye; Mardanian, Leila; Rahimi, Mojtaba

    2014-07-01

    Intensive care unit is a center to provide comprehensive care for critically ill patients whose condition can be improved by receiving specialized care. The importance of accurate and rapid monitoring of patients at this precise moment is in recording patient data and its comparison with previous data. Monitoring the patient by either devices or direct examination of the nurses requires accurate documentation. Hence, accuracy of the documentation is essential to enhance the quality of care, despite the high volume of data in intensive care unit. This study was conducted by review of domestic and international texts through Delphi method. There were 20 participants in Delphi stage. Data were collected by the questionnaires sent in two stages. Experts' panel was used to complete and finalize the obtained structures. Data analysis was conducted by descriptive statistics in the form of frequency percentage. In a review of 15 domestic and international flow sheets as well as 30 reference texts and 80 articles, 99 primary flow sheet structures were detected, of which 58 had a consensus of >70%. With the goal of avoiding repetition and making the recordable data brief, and with respect to the nurses' initial assessment in better planning and administration of care, a flow sheet was designed as a nursing admission sheet to be completed at the moment of admission. Its content and template had consensus among the panel of experts, and the instruction for complement of the sheets was finally developed. After obtaining content validity and including the given indications, daily monitoring sheet and admission sheet were developed.

  4. Noninvasive diffuse optical monitoring of head and neck tumor blood flow and oxygenation during radiation delivery

    Science.gov (United States)

    Dong, Lixin; Kudrimoti, Mahesh; Cheng, Ran; Shang, Yu; Johnson, Ellis L.; Stevens, Scott D.; Shelton, Brent J.; Yu, Guoqiang

    2012-01-01

    This study explored using a novel diffuse correlation spectroscopy (DCS) flow-oximeter to noninvasively monitor blood flow and oxygenation changes in head and neck tumors during radiation delivery. A fiber-optic probe connected to the DCS flow-oximeter was placed on the surface of the radiologically/clinically involved cervical lymph node. The DCS flow-oximeter in the treatment room was remotely operated by a computer in the control room. From the early measurements, abnormal signals were observed when the optical device was placed in close proximity to the radiation beams. Through phantom tests, the artifacts were shown to be caused by scattered x rays and consequentially avoided by moving the optical device away from the x-ray beams. Eleven patients with head and neck tumors were continually measured once a week over a treatment period of seven weeks, although there were some missing data due to the patient related events. Large inter-patient variations in tumor hemodynamic responses were observed during radiation delivery. A significant increase in tumor blood flow was observed at the first week of treatment, which may be a physiologic response to hypoxia created by radiation oxygen consumption. Only small and insignificant changes were found in tumor blood oxygenation, suggesting that oxygen utilizations in tumors during the short period of fractional radiation deliveries were either minimal or balanced by other effects such as blood flow regulation. Further investigations in a large patient population are needed to correlate the individual hemodynamic responses with the clinical outcomes for determining the prognostic value of optical measurements. PMID:22312579

  5. Field Programmable Gate Array (FPGA Respiratory Monitoring System Using a Flow Microsensor and an Accelerometer

    Directory of Open Access Journals (Sweden)

    Mellal Idir

    2017-04-01

    Full Text Available This paper describes a non-invasive system for respiratory monitoring using a Micro Electro Mechanical Systems (MEMS flow sensor and an IMU (Inertial Measurement Unit accelerometer. The designed system is intended to be wearable and used in a hospital or at home to assist people with respiratory disorders. To ensure the accuracy of our system, we proposed a calibration method based on ANN (Artificial Neural Network to compensate the temperature drift of the silicon flow sensor. The sigmoid activation functions used in the ANN model were computed with the CORDIC (COordinate Rotation DIgital Computer algorithm. This algorithm was also used to estimate the tilt angle in body position. The design was implemented on reconfigurable platform FPGA.

  6. Continuous flow left ventricular assist devices: shared care goals of monitoring and treating patients.

    Science.gov (United States)

    Estep, Jerry D; Trachtenberg, Barry H; Loza, Laurie P; Bruckner, Brian A

    2015-01-01

    Continuous-flow left ventricular assist devices (CF-LVADs) have been clinically adopted as a long-term standard of care therapy option for patients with end-stage heart failure. For many patients, shared care between the care providers at the implanting center and care providers in the community in which the patient resides is a clinical necessity. The aims of this review are to (1) provide a rationale for the outpatient follow-up exam and surveillance testing used at our center to monitor patients supported by the HeartMate II(®) CF-LVAD (Thoratec Corporation, Pleasanton, CA) and (2) provide the protocol/algorithms we use for blood pressure, driveline exit site, LVAD alarm history, surveillance blood work, and echocardiography monitoring in this patient population. In addition, we define our partnership outpatient follow-up protocol and the "shared care" specific responsibilities we use with referring health care providers to best manage many of our patients.

  7. A new model for turbidity current behavior based on integration of flow monitoring and precision coring in a submarine canyon

    Science.gov (United States)

    Symons, William O.; Sumner, Esther J.; Paull, Charles K.; Cartigny, Matthieu J.B.; Xu, Jingping; Maier, Katherine L.; Lorenson, Thomas; Talling, Peter J.

    2017-01-01

    Submarine turbidity currents create some of the largest sediment accumulations on Earth, yet there are few direct measurements of these flows. Instead, most of our understanding of turbidity currents results from analyzing their deposits in the sedimentary record. However, the lack of direct flow measurements means that there is considerable debate regarding how to interpret flow properties from ancient deposits. This novel study combines detailed flow monitoring with unusually precisely located cores at different heights, and multiple locations, within the Monterey submarine canyon, offshore California, USA. Dating demonstrates that the cores include the time interval that flows were monitored in the canyon, albeit individual layers cannot be tied to specific flows. There is good correlation between grain sizes collected by traps within the flow and grain sizes measured in cores from similar heights on the canyon walls. Synthesis of flow and deposit data suggests that turbidity currents sourced from the upper reaches of Monterey Canyon comprise three flow phases. Initially, a thin (38–50 m) powerful flow in the upper canyon can transport, tilt, and break the most proximal moorings and deposit chaotic sands and gravel on the canyon floor. The initially thin flow front then thickens and deposits interbedded sands and silty muds on the canyon walls as much as 62 m above the canyon floor. Finally, the flow thickens along its length, thus lofting silty mud and depositing it at greater altitudes than the previous deposits and in excess of 70 m altitude.

  8. Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow

    Science.gov (United States)

    Diop, Mamadou; Tichauer, Kenneth M.; Elliott, Jonathan T.; Migueis, Mark; Lee, Ting-Yim; St. Lawrence, Keith

    2010-02-01

    A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF). Since current non-invasive bedside methods can only indirectly assess blood flow, the goal of this research was to develop an optical technique for measuring absolute CBF. A time-resolved near-infrared (NIR) apparatus was built and its ability to accurately measure changes in optical properties was demonstrated in tissue-mimicking phantoms. The time-resolved system was combined with a bolus-tracking method for measuring CBF using the dye indocyanine green (ICG) as an intravascular flow tracer. Cerebral blood flow was measured in newborn piglets and for comparison, CBF was concurrently measured using a previously developed continuous-wave NIR method. Measurements were acquired with both techniques under three conditions: normocapnia, hypercapnia and following occlusion of the carotid arteries. Mean CBF values (N = 3) acquired with the TR-NIR system were 31.9 +/- 11.7 ml/100g/min during occlusion, 39.7 +/- 1.6 ml/100g/min at normocapnia, and 58.8 +/- 9.9 ml/100g/min at hypercapnia. Results demonstrate that the developed TR-NIR technique has the sensitivity to measure changes in CBF; however, the CBF measurements were approximately 25% lower than the values obtained with the CW-NIRS technique.

  9. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  10. The potentials of the third generation of flow injection analysis for nutrient monitoring and fractionation analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Buanuam, Janya

    2006-01-01

    In the present communication, the third generation of flow injection analysis, the so-called micro sequential-injection Laboratory-on-Valve (μSI-LOV), is presented as a miniaturized, automated approach for on-line monitoring of nutrients in different environmental compartments as effected under...... enclosed and strictly controlled conditions. Special emphasis is placed on coupling μSI-LOV on-line with a recently developed microcolumn to perform dynamic fractionation schemes for ascertaining the availability of phosphorous forms in solid substrates for biota uptake under simulated environmental...

  11. Cholestyramine Resin

    Science.gov (United States)

    ... as atherosclerosis) decreases blood flow and, therefore, the oxygen supply to your heart, brain, and other parts ... in a large glass to avoid excessive foaming. Drink the mixture slowly. Rinse the drinking glass with ...

  12. Robustness and quality of precipitation and river flow data obtained through participatory monitoring and citizen scienc

    Science.gov (United States)

    Buytaert, W.; Ochoa-Tocachi, B. F.

    2016-12-01

    Apart for the most basic measurements of manual rain and staff gauges, hydrology and water resources are not an evident disciplines for the application of citizen science. High-resolution measurements require elaborate equipment, installation, and maintenance that is typically beyond the scope of non-scientists. Additionally, hydrological analysis has traditionally relied upon long time series of consistent accuracy and precision. Nevertheless, new opportunities for public participation in hydrological research are emerging, driven by increasingly affordable, robust, and more user-friendly technology. Here we analyse the results generated by participatory monitoring of river flow and precipitation in around 30 catchments in the tropical Andes. This monitoring network was set up through a collaborative effort between scientists, NGOs and local communities, with the intention to generate evidence about the impact of land-use change on streamflow. Monitoring was implemented using automatic but low-cost sensors operated and maintained by local users. Tipping bucket rain gauges are used for precipitation, and river flow is monitored with pressure transducers in combination with a V-notch weir to obtain a stable stage-discharge relation. Jointly, the sensors have now collected an equivalent of more than 30 years of data, with a measurement interval of typically 5 or 15 minutes. Analysing the data, we find that the observations themselves tend to be of a quality comparable to scientific observations. However, main issues are related to the continuity of the time series, as sensors eventually fail or run out of capacity in dataloggers or batteries in the most remote locations. Despite these shortcomings, the data have proven to be useful in characterizing land-use impacts well beyond what can be achieved with conventional data collection, thus filling long-standing gaps in local hydrological knowledge. Furthermore, we expect that the advent of new, more robust, resilient

  13. Application of XAD-2 resin-based passive samplers and SPME–GC–MS/MS analysis for the monitoring of spatial and temporal variations of atmospheric pesticides in Luxembourg

    International Nuclear Information System (INIS)

    Schummer, Claude; Tuduri, Ludovic; Briand, Olivier; Appenzeller, Brice M.; Millet, Maurice

    2012-01-01

    Passive air sampling has been shown to be a very interesting alternative to high-volume sampling by overcoming its disadvantages (size, weight, expensiveness). However, to date, only limited data is available about passive air sampling of current-use pesticides. In order to test if passive samplers allow monitoring of spatial and temporal variations of atmospheric pesticide concentrations, five XAD-2-resin based passive air samplers were deployed at five locations in Luxembourg. Samplers were analyzed using accelerated solvent extraction coupled to solid-phase microextraction and gas chromatography with tandem mass spectrometry. Collected data was used to study the spatial and temporal variations of the concentrations of the compounds. Twenty two pesticides were detected between March and October, while no pesticides were detected from November to February. Highest concentrations were measured on the rural sites, suggesting that the used XAD-2 resin-based passive samplers allow the simultaneous monitoring of multiple current-use pesticides and identifying spatial and temporal variations. - Highlights: ► XAD-2 passive sampling of current-used pesticides. ► Coupling of ASE and SPME–GC–MS/MS for the analysis of pesticides in XAD-2 passive sampling. ► XAD-2 passive samplers suitable for current-used pesticides atmospheric sampling. ► XAD-2 passive samplers suitable for spatial and temporal atmospheric concentrations variations. - XAD-2 passive sampling of current-use pesticides in the atmosphere.

  14. Application of XAD-2 resin-based passive samplers and SPME-GC-MS/MS analysis for the monitoring of spatial and temporal variations of atmospheric pesticides in Luxembourg.

    Science.gov (United States)

    Schummer, Claude; Tuduri, Ludovic; Briand, Olivier; Appenzeller, Brice M; Millet, Maurice

    2012-11-01

    Passive air sampling has been shown to be a very interesting alternative to high-volume sampling by overcoming its disadvantages (size, weight, expensiveness). However, to date, only limited data is available about passive air sampling of current-use pesticides. In order to test if passive samplers allow monitoring of spatial and temporal variations of atmospheric pesticide concentrations, five XAD-2-resin based passive air samplers were deployed at five locations in Luxembourg. Samplers were analyzed using accelerated solvent extraction coupled to solid-phase microextraction and gas chromatography with tandem mass spectrometry. Collected data was used to study the spatial and temporal variations of the concentrations of the compounds. Twenty two pesticides were detected between March and October, while no pesticides were detected from November to February. Highest concentrations were measured on the rural sites, suggesting that the used XAD-2 resin-based passive samplers allow the simultaneous monitoring of multiple current-use pesticides and identifying spatial and temporal variations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Review: Resin Composite Filling

    Directory of Open Access Journals (Sweden)

    Desmond Ng

    2010-02-01

    Full Text Available The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin composite has aesthetic advantages over amalgam, one of the major disadvantage include polymerization shrinkage and future research is needed on reaction kinetics and viscoelastic behaviour to minimize shrinkage stress.

  16. Review: Resin Composite Filling

    Science.gov (United States)

    Chan, Keith H. S.; Mai, Yanjie; Kim, Harry; Tong, Keith C. T.; Ng, Desmond; Hsiao, Jimmy C. M.

    2010-01-01

    The leading cause of oral pain and tooth loss is from caries and their treatment include restoration using amalgam, resin, porcelain and gold, endodontic therapy and extraction. Resin composite restorations have grown popular over the last half a century because it can take shades more similar to enamel. Here, we discuss the history and use of resin, comparison between amalgam and resin, clinical procedures involved and finishing and polishing techniques for resin restoration. Although resin composite has aesthetic advantages over amalgam, one of the major disadvantage include polymerization shrinkage and future research is needed on reaction kinetics and viscoelastic behaviour to minimize shrinkage stress.

  17. RTM Production Monitoring of the A380 Hinge Arm Droop Nose Mechanism: A Multi-Sensor Approach

    Directory of Open Access Journals (Sweden)

    Gabriele Chiesura

    2016-06-01

    Full Text Available This research presents a case study of production monitoring on an aerospace composite component: the hinge arm of the droop nose mechanism on the Airbus A380 wing leading edge. A sensor network composed of Fibre Bragg Gratings, capacitive sensors for cure monitoring and thermocouples was embedded in its fibre reinforced lay-up and measurements were acquired throughout its Resin Transfer Moulding production process. Two main challenges had to be overcome: first, the integration of the sensor lines in the existing Resin Transfer Moulding mould without modifying it; second, the demoulding of the component without damaging the sensor lines. The proposed embedding solution has proved successful. The wavelength shifts of the Fibre Bragg Gratings were observed from the initial production stages, over the resin injection, the complete curing of the resin and the cooling-down prior to demoulding. The sensors proved to be sensitive to detecting the resin flow front, vacuum and pressure increase into the mould and the temperature increase caused by the resin curing. Measurements were also acquired during the post-curing cycle. Residual strains during all steps of the process were derived from the sensors’ wavelength shift, showing values up to 0.2% in compression. Moreover, the capacitive sensors were able to follow-up the curing degree during the production process. The sensors proved able to detect the resin flow front, whereas thermocouples could not measure an appreciable increase of temperature due to the fact that the resin had the same temperature as the mould.

  18. Effects of episodic sediment supply on bedload transport rate in mountain rivers. Detecting debris flow activity using continuous monitoring

    Science.gov (United States)

    Uchida, Taro; Sakurai, Wataru; Iuchi, Takuma; Izumiyama, Hiroaki; Borgatti, Lisa; Marcato, Gianluca; Pasuto, Alessandro

    2018-04-01

    Monitoring of sediment transport from hillslopes to channel networks as a consequence of floods with suspended and bedload transport, hyperconcentrated flows, debris and mud flows is essential not only for scientific issues, but also for prevention and mitigation of natural disasters, i.e. for hazard assessment, land use planning and design of torrent control interventions. In steep, potentially unstable terrains, ground-based continuous monitoring of hillslope and hydrological processes is still highly localized and expensive, especially in terms of manpower. In recent years, new seismic and acoustic methods have been developed for continuous bedload monitoring in mountain rivers. Since downstream bedload transport rate is controlled by upstream sediment supply from tributary channels and bed-external sources, continuous bedload monitoring might be an effective tool for detecting the sediments mobilized by debris flow processes in the upper catchment and thus represent an indirect method to monitor slope instability processes at the catchment scale. However, there is poor information about the effects of episodic sediment supply from upstream bed-external sources on downstream bedload transport rate at a single flood time scale. We have examined the effects of sediment supply due to upstream debris flow events on downstream bedload transport rate along the Yotagiri River, central Japan. To do this, we have conducted continuous bedload observations using a hydrophone (Japanese pipe microphone) located 6.4 km downstream the lower end of a tributary affected by debris flows. Two debris flows occurred during the two-years-long observation period. As expected, bedload transport rate for a given flow depth showed to be larger after storms triggering debris flows. That is, although the magnitude of sediment supply from debris flows is not large, their effect on bedload is propagating >6 km downstream at a single flood time scale. This indicates that continuous bedload

  19. Designing and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel

    Directory of Open Access Journals (Sweden)

    Akbari H.

    2014-06-01

    Full Text Available Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time. Objective: The aim of this study was to construct blood flow monitoring system on the heel tissue which was under external pressure in order to evaluate the tissue treatment in the ulcer. Methods: To measure the blood flow changes, three infrared optical transmitters were used at the distances of 5, 10, and 15 mm to the receiver. Blood flow changes in heels were assessed in pressures 0, 30, and 60 mmHg. The time features were extracted for analysis from the recorded signal by MATLAB software. Changes of the time features under different pressures were evaluated at the three distances by ANOVA in SPSS software. The level of significance was considered at 0.05. Results: In this study, 15 subjects, including both male and female, with the mean age of 54±7 participated. The results showed that the signal amplitude, power and absolute signal decreased significantly when pressure on the tissue increased in different layers (p<0.05. Heart rate only decreased significantly in pressures more than 30 mmHg (p=0.02. In pressures more than 30 mmHg, in addition to a decrease in the time features, the pattern of blood flow signal changed and it wasn’t the same as noload signal. Conclusion: By detecting the time features, we can reach an early diagnosis to prognosticate the degeneration of the tissue under pressure and it can be recommended as a method to predict bedsores in the heel.

  20. Noise and DC balanced outlet temperature signals for monitoring coolant flow in LMFBR fuel elements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1977-01-01

    Local cooling disturbances in LMFBR fuel elements may have serious safety implications for the whole reactor core. They have to be detected reliably in an early stage of their formation therefore. This can be accomplished in principle by individual monitoring of the coolant flow rate or the coolant outlet temperature of the sub-assemblies with high precision. In this paper a method is proposed to increase the sensitivity of outlet temperature signals to cooling disturbances. Using balanced temperature signals provides a means for eliminating the normal variations from the original signals which limit the sensitivity and speed of response to cooling disturbances. It is shown that a balanced signal can be derived easily from the original temperature signal by subtracting an inlet temperature and a neutron detector signal with appropriate time shift. The method was tested with tape-recorded noise signals of the KNK I reactor at Karlsruhe. The experimental results confirm the theoretical predictions. A significant reduction of the uncertainty of measured outlet temperatures was achieved. This enables very sensitive and fast response monitoring of coolant flow. Furthermore, it was found that minimizing the variance of the balanced signal offers the possibility for a rough determination of the heat transfer coefficient of the fuel rods during normal reactor operation at power. (author)

  1. Monitoring of water flow inside stalactites of the Rochefort karstic laboratory

    Science.gov (United States)

    van Ruymbeke, Michel; Dumont, Philippe

    2017-04-01

    The Royal Observatory has developped the « Dropmeter » which is an original gauge to monitore in real time the diameters of drops produced by the water flowing through stalactites. After presentation of the technical design, we describe the way to simulate in laboratory the use of the system. A series of « Dropmeter » was experienced in the karstic cave of « Notre-Dame de Lorette » in Rochefort city (Belgium). Three stalactites were equiped with this sensor for a permanent monitoring at a sampling rate of one minute. Analysis of records applies the HiCum stacking to extract geophysical modulations on different periodicities. Interactions with different Geophysical parameters are confirmed. It concerns variation of signal in the spectral band centered on the diurnal thermal wave S1 (24h), the semi-diurnal atmospheric pressure modulation S2(12h), the lunar main wave M2 and some monthly waves. In the non harmonic domain, the water flow seems to be modulated by the quantity of water in the vadose zone which is correlated to the precipitation.

  2. Rapid response sensor to monitor the temperature and flow of liquid metals

    International Nuclear Information System (INIS)

    McCann, J.D.

    1980-01-01

    Two forms of a sensor capable of simultaneously monitoring the temperature and flow of liquid metal coolants within a reactor are described. They operate by measuring the coupling impedances between the sensor and the surrounding electrically conductive coolant. Since the system utilises electrical rather than thermal properties, the response to perturbations is rapid, typically displaying the changed conditions within a few milliseconds. The first form of the sensor was designed to operate whilst protected by a thick walled service tube positioned in the reactor coolant. Providing bends in the tube had a radius greater than 70 cm, the sensor could be removed for inspection and maintenance if necessary. The second sensor was fitted inside a streamlined NaK proof capsule. This was inserted directly into the coolant outlet stream of a fuel pin assembly in the Dounreay Fast Reactor. In this form the sensor successfully monitored flow, entrained gas and temperature excursions during the final operating cycle of D.F.R. (author)

  3. Blood viscosity monitoring during cardiopulmonary bypass based on pressure-flow characteristics of a Newtonian fluid.

    Science.gov (United States)

    Okahara, Shigeyuki; Zu Soh; Takahashi, Shinya; Sueda, Taijiro; Tsuji, Toshio

    2016-08-01

    We proposed a blood viscosity estimation method based on pressure-flow characteristics of oxygenators used during cardiopulmonary bypass (CPB) in a previous study that showed the estimated viscosity to correlate well with the measured viscosity. However, the determination of the parameters included in the method required the use of blood, thereby leading to high cost of calibration. Therefore, in this study we propose a new method to monitor blood viscosity, which approximates the pressure-flow characteristics of blood considered as a non-Newtonian fluid with characteristics of a Newtonian fluid by using the parameters derived from glycerin solution to enable ease of acquisition. Because parameters used in the estimation method are based on fluid types, bovine blood parameters were used to calculate estimated viscosity (ηe), and glycerin parameters were used to estimate deemed viscosity (ηdeem). Three samples of whole bovine blood with different hematocrit levels (21.8%, 31.0%, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37 °C to 27 °C, the oxygenator mean inlet pressure and outlet pressure were recorded for flows of 2 L/min and 4 L/min, and the viscosity was estimated. The value of deemed viscosity calculated with the glycerin parameters was lower than estimated viscosity calculated with bovine blood parameters by 20-33% at 21.8% hematocrit, 12-27% at 31.0% hematocrit, and 10-15% at 39.8% hematocrit. Furthermore, deemed viscosity was lower than estimated viscosity by 10-30% at 2 L/min and 30-40% at 4 L/min. Nevertheless, estimated and deemed viscosities varied with a similar slope. Therefore, this shows that deemed viscosity achieved using glycerin parameters may be capable of successfully monitoring relative viscosity changes of blood in a perfusing oxygenator.

  4. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring.

    Science.gov (United States)

    Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F

    2017-04-15

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The performance of passive flow monitors and phosphate accumulating passive samplers when exposed to pulses in external water flow rate and/or external phosphate concentrations

    International Nuclear Information System (INIS)

    O'Brien, Dominique; Hawker, Darryl; Shaw, Melanie; Mueller, Jochen F.

    2011-01-01

    Passive samplers are typically calibrated under constant flow and concentration conditions. This study assessed whether concentration and/or flow pulses could be integrated using a phosphate passive sampler (P-sampler). Assessment involved three 21-day experiments featuring a pulse in flow rate, a pulse of filterable reactive phosphate (FRP) concentration and a simultaneous concentration and flow pulse. FRP concentrations were also determined by parallel grab sampling and the P-sampler calibrated with passive flow monitors (PFMs) and direct measurement of flow rates. The mass lost from the PFM over the deployment periods predicted water velocity to within 5.1, 0.48 and 7.1% when exposed to a flow rate pulse (7.5-50 cm s -1 ), concentration pulse (5-100 μg P L -1 ), or both simultaneously. For the P-sampler, good agreement was observed between the grab and passive measurements of FRP concentration when exposed to a pulse in flow (6% overestimation) or concentration (2% underestimation). - Highlights: → We assess the performance of the passive flow monitor and a phosphate passive sampler when exposed to changing environmental conditions. → The PFM responded quickly and accurately to a pulse in flow rate but showed little response to an external FRP pulse. → The ability of the sampler to provide an integrated measure of the average phosphate concentrations has been demonstrated. → The results presented demonstrate under which conditions the greatest accuracy is achieved when employing passive samplers. - The performance of an integrative phosphate passive sampler has been assessed when exposed to pulses in flow rate and concentration, both individually and simultaneously.

  6. Resin-Powder Dispenser

    Science.gov (United States)

    Standfield, Clarence E.

    1994-01-01

    Resin-powder dispenser used at NASA's Langley Research Center for processing of composite-material prepregs. Dispenser evenly distributes powder (resin polymer and other matrix materials in powder form) onto wet uncured prepregs. Provides versatility in distribution of solid resin in prepreg operation. Used wherever there is requirement for even, continuous distribution of small amount of powder.

  7. Monitoring of Legionella pneumophila viability after chlorine dioxide treatment using flow cytometry.

    Science.gov (United States)

    Mustapha, Pascale; Epalle, Thibaut; Allegra, Séverine; Girardot, Françoise; Garraud, Olivier; Riffard, Serge

    2015-04-01

    The viability of three Legionella pneumophila strains was monitored after chlorine dioxide (ClO2) treatment using a flow cytometric assay. Suspensions of L. pneumophila cells were submitted to increasing concentrations of ClO2. Culturable cells were still detected when using 4 mg/L, but could no longer be detected after exposure to 6 mg/L of ClO2, although viable but not culturable (VBNC) cells were found after exposure to 4-5 mg/L of ClO2. When testing whether these VBNC were infective, two of the strains were resuscitated after co-culture with Acanthamoeba polyphaga, but neither of them could infect macrophage-like cells. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  8. Monitoring strategies of stream phosphorus under contrasting climate-driven flow regimes

    DEFF Research Database (Denmark)

    Goyenola, Guillermo; Meerhoff, Marianna; Teixeira-de Mello, Franco

    2015-01-01

    Climate and hydrology are relevant control factors determining the timing and amount of nutrient losses from land to downstream aquatic systems, in particular of phosphorus (P) from agricultural lands. The main objective of the study was to evaluate the differences in P export patterns and the pe...... relevant in currently flashy systems and also in systems where climate change predictions suggest an increase in stream flashiness.......Climate and hydrology are relevant control factors determining the timing and amount of nutrient losses from land to downstream aquatic systems, in particular of phosphorus (P) from agricultural lands. The main objective of the study was to evaluate the differences in P export patterns...... and the performance of alternative monitoring strategies in streams under contrasting climate-driven flow regimes. We compared a set of paired streams draining lowland micro-catchments under temperate climate and stable discharge conditions (Denmark) and under sub-tropical climate and flashy conditions (Uruguay). We...

  9. Development by flow cytometry of bioassays based on chlorella for environmental monitoring

    Directory of Open Access Journals (Sweden)

    Petrescu C-M,

    2016-05-01

    Full Text Available In ecotoxicological assessments, bioassays (ecotoxicity tests or biotests are one of the main tools, defined as methods which use living cells, tissues, organism or communities to assess exposure-related effects of chemicals. The increasing complexity of environmental degradation requires an increase in the capacity of scientific approach in monitoring and notification as early as possible risks. Our own objective concerns the detection of aquatic environment pollution in Romania and particularly in the Danube basin. For assessing aquatic environment pollution degree or for assessing cytotoxicity or ecotoxicity of pollutants (heavy metals, nanoparticles, pesticides, etc. we developed news experimental bioassays based on the use of viability and apoptosis biomarkers of Chlorella cells by flow cytometry. Our proposed bioassays could be rapid and very sensitive tests for in laboratory aquatic risk assessment and biomonitoring.

  10. An XMM-Newton Monitoring Campaign of the Accretion Flow in IGRJ16318-4848

    Science.gov (United States)

    Mushotzky, Richard (Technical Monitor); Nicastro, Fabrizio

    2005-01-01

    This grant is associated to a successful XMM-Newton-AO3 observational proposal to monitor the spectrum of the X-ray loud component of the recently discovered binary system IGR J16138-4848, to study the conditions of the accretion flows (and their evolution) in binary system. All four EPIC-PN and MOS observations of the target have now been performed (the last one of the 4, only 3 months ago). The four observations were logarithmically spaced, so to cover timescales from days to months. Data from all four pointings have now been reduced, using the XMM-Newton data reduction pipeline, and spectra and lightcurves from the target have been extracted. For the first three observations we have already performed the observation-by-observation data analysis, by fitting the single EPIC spectra with spectral models that include an intrinsic continuum power law (reduced at low energy by neutral absorption), a 6.4 keV iron emission line (detected in all spectra with varying intensity) and a Compton-reflection component. A Compton reflection component is also detected in all spectra, although at lower significance. The analysis of the fourth and last observation of our monitoring campaign has just recently begun. Next, we will (1) stack together the four observations of IGR J16138-4848, to obtain high-accuracy estimates of the average spectral parameters of this object; and then (2) proceed to the time-evolving analysis, of the three spectral parameters: (a) Gamma (the slope of the intrinsic continuum), (b) W(FeK), the equivalent width of the 6.4 keV Iron emission line, and (c) R, the relative amount of Compton reflection. Through this time-resolved spectroscopic analysis we hope to constrain (a) the physical state of the accreting matter and its relation with the X-ray output, and (b) the evolution of the accretion flow geometry, distribution and covering factor.

  11. In-line monitoring and optimization of powder flow in a simulated continuous process using transmission near infrared spectroscopy.

    Science.gov (United States)

    Alam, Md Anik; Shi, Zhenqi; Drennen, James K; Anderson, Carl A

    2017-06-30

    In-line monitoring of continuous powder flow is an integral part of the continuous manufacturing process of solid oral dosage forms in the pharmaceutical industry. Specifically, monitoring downstream from loss-in-weight (LIW) feeders and/or continuous mixers provides important data about the state of the process. Such measurements support control of the process and thereby enhance product quality. Near Infrared Spectroscopy (NIRS) is a potential PAT tool to monitor the homogeneity of a continuous powder flow stream in pharmaceutical manufacturing. However, the association of analytical results from NIR sampling of the powder stream and the homogeneity (content uniformity) of the resulting tablets provides several challenges; appropriate sampling strategies, adequately robust modeling techniques and poor sensitivities (for low dose APIs) are amongst them. Information from reflectance-based NIRS sampling is limited. The region of the powder bed that is interrogated is confined to the surface where the measurement is made. This potential bias in sampling may, in turn, limit the ability to predict the homogeneity of the finished dosage form. Further, changes to the processing parameters (e.g., rate of powder flow) often have a significant effect on the resulting data. Sample representation, interdependence between process parameters and their effects on powder flow behavior are critical factors for NIRS monitoring of continuous powder flow system. A transmission NIR method was developed as an alternative technique to monitor continuous powder flow and quantify API in the powder stream. Transmission NIRS was used to determine the thickness of the powder stream flowing from a loss-in-weight feeder. The thickness measurement of the powder stream provided an in-depth understanding about the effects of process parameters such as tube angles and powder flow rates on powder flow behaviors. This knowledge based approach helped to define an analytical design space that was

  12. Thermal cycling effects on adhesion of resin-bovine enamel junction among different composite resins.

    Science.gov (United States)

    Chen, Wen-Cheng; Ko, Chia-Ling; Wu, Hui-Yu; Lai, Pei-Ling; Shih, Chi-Jen

    2014-10-01

    Thermal cycling is used to mimic the changes in oral cavity temperature experienced by composite resins when used clinically. The purpose of this study is to assess the thermal cycling effects of in-house produced composite resin on bonding strength. The dicalcium phosphate anhydrous filler surfaces are modified using nanocrystals and silanization (w/NP/Si). The resin is compared with commercially available composite resins Filtek Z250, Z350, and glass ionomer restorative material GIC Fuji-II LC (control). Different composite resins were filled into the dental enamel of bovine teeth. The bond force and resin-enamel junction graphical structures of the samples were determined after thermal cycling between 5 and 55°C in deionized water for 600 cycles. After thermal cycling, the w/NP/Si 30wt%, 50wt% and Filtek Z250, Z350 groups showed higher shear forces than glass ionomer GIC, and w/NP/Si 50wt% had the highest shear force. Through SEM observations, more of the fillings with w/NP/Si 30wt% and w/NP/Si 50wt% groups flowed into the enamel tubule, forming closed tubules with the composite resins. The push-out force is proportional to the resin flow depth and uniformity. The push-out tubule pore and resin shear pattern is the most uniform and consistent in the w/NP/Si 50wt% group. Accordingly, this developed composite resin maintains great mechanical properties after thermal cycling. Thus, it has the potential to be used in a clinical setting when restoring non-carious cervical lesions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Improved nonlinear fault detection strategy based on the Hellinger distance metric: Plug flow reactor monitoring

    KAUST Repository

    Harrou, Fouzi

    2017-03-18

    Fault detection has a vital role in the process industry to enhance productivity, efficiency, and safety, and to avoid expensive maintenance. This paper proposes an innovative multivariate fault detection method that can be used for monitoring nonlinear processes. The proposed method merges advantages of nonlinear projection to latent structures (NLPLS) modeling and those of Hellinger distance (HD) metric to identify abnormal changes in highly correlated multivariate data. Specifically, the HD is used to quantify the dissimilarity between current NLPLS-based residual and reference probability distributions obtained using fault-free data. Furthermore, to enhance further the robustness of these methods to measurement noise, and reduce the false alarms due to modeling errors, wavelet-based multiscale filtering of residuals is used before the application of the HD-based monitoring scheme. The performances of the developed NLPLS-HD fault detection technique is illustrated using simulated plug flow reactor data. The results show that the proposed method provides favorable performance for detection of faults compared to the conventional NLPLS method.

  14. Immune Monitoring in Cancer Vaccine Clinical Trials: Critical Issues of Functional Flow Cytometry-Based Assays

    Directory of Open Access Journals (Sweden)

    Iole Macchia

    2013-01-01

    Full Text Available The development of immune monitoring assays is essential to determine the immune responses against tumor-specific antigens (TSAs and tumor-associated antigens (TAAs and their possible correlation with clinical outcome in cancer patients receiving immunotherapies. Despite the wide range of techniques used, to date these assays have not shown consistent results among clinical trials and failed to define surrogate markers of clinical efficacy to antitumor vaccines. Multiparameter flow cytometry- (FCM- based assays combining different phenotypic and functional markers have been developed in the past decade for informative and longitudinal analysis of polyfunctional T-cells. These technologies were designed to address the complexity and functional heterogeneity of cancer biology and cellular immunity and to define biomarkers predicting clinical response to anticancer treatment. So far, there is still a lack of standardization of some of these immunological tests. The aim of this review is to overview the latest technologies for immune monitoring and to highlight critical steps involved in some of the FCM-based cellular immune assays. In particular, our laboratory is focused on melanoma vaccine research and thus our main goal was the validation of a functional multiparameter test (FMT combining different functional and lineage markers to be applied in clinical trials involving patients with melanoma.

  15. Real time monitoring of tritium concentration in hydrogen gas with a gas-flow proportional counter

    International Nuclear Information System (INIS)

    Ogata, Y.; Hasegawa, S.; Aoyama, T.

    2002-01-01

    A gas-flow type proportional counter was devised for real time monitoring of tritium concentration in hydrogen gas generated by electrolysis of tritiated water. Since organic gases such as PR gas cannot use as the counting gas for this study, the feasibility of hydrogen gas for the counting gas was experimentally studied. The counter made of brass was of 29-mm in inner diameter, 37-cm long, with a volume of 166-cm 3 . The plateau potential of the counter resulted in 2100-2400 V using hydrogen gas as the counting gas, which was approximately the same as that for PR gas. Therefore, the operating voltage was determined to 2300 V. The effective volume of the counter was measured and found to be 134 cm 3 for hydrogen gas. Although the pulse height of the counter observed with hydrogen counting gas was 20 times lower than that with PR gas, tritium detection was performed without problem. The minimum detectable concentration of tritium for the counter was estimated as 0.034 Bq cm -3 with a counting time of 6 s. The counter was found to be effective for real time monitoring of tritium concentration in hydrogen gas generated by the electrolysis. (author)

  16. Stakeholder Participation in Freshwater Monitoring and Evaluation Programs: Applying Thresholds of Potential Concern within Environmental Flows

    Science.gov (United States)

    Conallin, John; McLoughlin, Craig A.; Campbell, Josh; Knight, Roger; Bright, Troy; Fisher, Ian

    2018-03-01

    The complex nature of freshwater systems provides challenges for incorporating evidence-based techniques into management. This paper investigates the potential of participatory evidence-based techniques to involve local stakeholders and make decisions based on different "knowledge" sources within adaptive management programs. It focuses on the application of thresholds of potential concern (TPC) within strategic adaptive management (SAM) for facilitating inclusive decision-making. The study is based on the case of the Edward-Wakool (E-W) "Fish and Flows" SAM project in the Murray-Darling River Basin, Australia. We demonstrate the application of TPCs for improving collaborative decision-making within the E-W, associated with environmental watering requirements, and other natural resource management programs such as fish stocking. The development of TPCs in the E-W fish and flows SAM project helped improve stakeholder involvement and understanding of the system, and also the effectiveness of the implemented management interventions. TPCs ultimately helped inform environmental flow management activities. The TPC process complemented monitoring that was already occurring in the system and provided a mechanism for linking formal and informal knowledge to form explicit and measurable endpoints from objectives. The TPC process faced challenges due to the perceived reduction in scientific rigor within initial TPC development and use. However, TPCs must remain tangible to managers and other stakeholders, in order to aid in the implementation of adaptive management. Once accepted by stakeholders, over time TPCs should be reviewed and refined in order to increase their scientific rigor, as new information is generated.

  17. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring

    KAUST Repository

    Van Nevel, S.

    2017-02-08

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.

  18. Optimization of mass of plastic scintillator film for flow-cell based tritium monitoring: a Monte Carlo study

    International Nuclear Information System (INIS)

    Roy, Arup Singha; Palani Selvam, T.; Raman, Anand; Raja, V.; Chaudhury, Probal

    2014-01-01

    Over the years, various types of tritium-in-air monitors have been designed and developed based on different principles. Ionization chamber, proportional counter and scintillation detector systems are few among them. A plastic scintillator based, flow-cell type online tritium-in-air monitoring system was developed for online monitoring of tritium in air. The value of the scintillator mass inside the cell-volume, which maximizes the response of the detector system, should be obtained to get maximum efficiency. The present study is aimed to optimize the amount of mass of the plastic scintillator film for the flow-cell based tritium monitoring instrument so that maximum efficiency is achieved. The Monte Carlo based EGSnrc code system has been used for this purpose

  19. Innovative Coal Solids-Flow Monitoring and Measurement Using Phase-Doppler and Mie Scattering Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Seong Lee

    2010-01-19

    Fuel flow to individual burners is complicated and difficult to determine on coal fired boilers, since coal solids were transported in a gas suspension that is governed by the complex physics of two-phase flow. The objectives of the project were the measurements of suspended coal solids-flows in the simulated test conditions. Various extractive methods were performed manually and can give only a snapshot result of fuel distribution. In order to measure particle diameter & velocity, laser based phase-Doppler particle analyzer (PDPA) and particle image velocimetry (PIV) were carefully applied. Statistical methods were used to analyze particle characteristics to see which factors have significant effect. The transparent duct model was carefully designed and fabricated for the laser-based-instrumentation of solids-flow monitoring (LISM). The experiments were conducted with two different kinds of particles with four different particle diameters. The particle types were organic particles and saw dust particles with the diameter range of 75-150 micron, 150-250 micron, 250-355 micron and 355-425 micron. The densities of the particles were measured to see how the densities affected the test results. Also the experiment was conducted with humid particles and fog particles. To generate humid particles, the humidifier was used. A pipe was connected to the humidifier to lead the particle flow to the intersection of the laser beam. The test results of the particle diameter indicated that, the mean diameter of humid particles was between 6.1703 microns and 6.6947 microns when the humid particle flow was low. When the humid particle flow was high, the mean diameter was between 6.6728 microns and 7.1872 microns. The test results of the particle mean velocity indicated that the mean velocity was between 1.3394 m/sec and 1.4556 m/sec at low humid particle flow. When the humid particle flow was high, the mean velocity was between 1.5694 m/sec and 1.7856 m/sec. The Air Flow Module, TQ

  20. Respiratory Sound Analysis for Flow Estimation During Wakefulness and Sleep, and its Applications for Sleep Apnea Detection and Monitoring

    Science.gov (United States)

    Yadollahi, Azadeh

    Tracheal respiratory sounds analysis has been investigated as a non--invasive method to estimate respiratory flow and upper airway obstruction. However, the flow--sound relationship is highly variable among subjects which makes it challenging to estimate flow in general applications. Therefore, a robust model for acoustical flow estimation in a large group of individuals did not exist before. On the other hand, a major application of acoustical flow estimation is to detect flow limitations in patients with obstructive sleep apnea (OSA) during sleep. However, previously the flow--sound relationship was only investigated during wakefulness among healthy individuals. Therefore, it was necessary to examine the flow--sound relationship during sleep in OSA patients. This thesis takes the above challenges and offers innovative solutions. First, a modified linear flow--sound model was proposed to estimate respiratory flow from tracheal sounds. To remove the individual based calibration process, the statistical correlation between the model parameters and anthropometric features of 93 healthy volunteers was investigated. The results show that gender, height and smoking are the most significant factors that affect the model parameters. Hence, a general acoustical flow estimation model was proposed for people with similar height and gender. Second, flow--sound relationship during sleep and wakefulness was studied among 13 OSA patients. The results show that during sleep and wakefulness, flow--sound relation- ship follows a power law, but with different parameters. Therefore, for acoustical flow estimation during sleep, the model parameters should be extracted from sleep data to have small errors. The results confirm reliability of the acoustical flow estimation for investigating flow variations during both sleep and wakefulness. Finally, a new method for sleep apnea detection and monitoring was developed, which only requires recording the tracheal sounds and the blood

  1. Evaluation of the Electronic Bubbler Gas Monitoring System for High Flow in the BaBar Detector

    International Nuclear Information System (INIS)

    Little, Angela

    2003-01-01

    We evaluated the gas monitoring system in the Instrumented Flux Return (IFR) portion of the BaBar detector at the Stanford Linear Accelerator Center (SLAC) to determine its suitability for flows greater than 80 cc/min. Future modifications to the IFR involve particle detectors with a higher gas flow rate than currently in use. Therefore, the bubbler system was tested to determine if it can handle high flow rates. Flow rates between 80 and 240 cc/min were analyzed through short term calibration and long term stability tests. The bubbler system was found to be reliable for flow rates between 80 and 160 cc/min. For flow rates between 200 and 240 cc/min, electronic instabilities known as baseline spikes caused a 10-20% error in the bubble rate. An upgrade would be recommended for use of the bubbler system at these flow rates. Since the planned changes in the IFR will require a maximum flow of 150 cc/min, the bubbler system can sufficiently handle the new gas flow rates

  2. Using ultrasonography to monitor liver blood flow for liver transplant from donors supported on extracorporeal membrane oxygenation.

    Science.gov (United States)

    Zhu, Xian-Sheng; Wang, Sha-Sha; Cheng, Qi; Ye, Chuang-Wen; Huo, Feng; Li, Peng

    2016-02-01

    Extracorporeal membrane oxygenation (ECMO) has been used to support brain-dead donors for liver procurement. This study investigated the potential role of ultrasonographic monitoring of hepatic perfusion as an aid to improve the viability of liver transplants obtained from brain-dead donors who are supported on ECMO. A total of 40 brain-dead patients maintained on ECMO served as the study population. Hepatic blood flow was monitored using ultrasonography, and perioperative optimal perfusion was maintained by calibrating ECMO. Liver function tests were performed to assess the viability of the graft. The hepatic arterial blood flow was well maintained with no significant changes observed before and after ECMO (206 ± 32 versus 241 ± 45 mL/minute; P = 0.06). Similarly, the portal venous blood flow was also maintained throughout (451 ± 65 versus 482 ± 77 mL/minute; P = 0.09). No significant change in levels of total bilirubin, alanine transaminase, and lactic acid were reported during ECMO (P = 0.17, P = 0.08, and P = 0.09, respectively). Before the liver is procured, ultrasonographic monitoring of hepatic blood flow could be a valuable aid to improve the viability of a liver transplant by allowing for real-time calibration of ECMO perfusion in brain-dead liver donors. In our study, ultrasonographic monitoring helped prevent warm ischemic injury to the liver graft by avoiding both overperfusion and underperfusion of the liver. © 2015 American Association for the Study of Liver Diseases.

  3. [Flow cytometry controlled induction therapy with ATG and noninvasive monitoring of rejection--a modern management concept after heart transplantation].

    Science.gov (United States)

    Wagner, F M; Tugtekin, S M; Matschke, K; Platzbecker, U; Gulielmos, V; Schüler, S

    1998-01-01

    We introduce our concept of non-invasive transplant monitoring. The introduction of individualized immunosuppression by means of flow cytometry leads to a lower incidence of acute graft rejection and preserves immuncompetence. With the simultaneous use of echocardiography and intramyocardial electrogram (IMEG) acute graft rejections can be safely identified without using any invasive method.

  4. Low-Cost Sensor Network for Stream Flow Monitoring in the Alto Beni Region of Bolivia

    Science.gov (United States)

    Rowe, M. D.; Fry, L. M.; Mihelcic, J. R.

    2009-12-01

    Lack of data is a persistent problem in hydrology and other field work in developing countries. Low cost monitoring devices allow investigators to maximize spatial coverage on a limited budget, as well as to minimize the financial risk of loss of instruments placed in vulnerable locations. This work contributes to an ongoing project to evaluate the sustainability of discharge from springs supplying gravity-fed potable water systems in the Alto Beni region of Bolivia where land use is rapidly changing from forest to agriculture. The approach is to estimate ground water recharge as a function of land use variables using a water balance model in several representative watersheds. Monthly stream discharge is currently estimated using monthly manual measurements of water level by a local technician. Continuous water level measurements will allow an improved estimate of the cumulative discharge, and generate data on statistical distribution of daily flow that may be useful to estimate discharge in similar, ungaged watersheds. Continuous water level measurements, along with available precipitation data, will allow analysis and comparison of the response of watersheds to individual precipitation events as a function of land use variables. We assembled a low cost level logging system for stream flow monitoring that measures and records distance up to 6 m to the nearest 25 mm every ten minutes, and runs for a month on six rechargeable AA batteries. The system consists of a sonic range finder sensor (MaxSonar-EZ2, Maxbotix Inc., Baxter, MN, 30), a temperature sensor (MCP9701, Microchip Technology Inc., Chandler, AZ, 0.25), and a datalogger (Hobo U12, Onset Computer Corp., Pocasset, MA, 104) along with a weather-resistant enclosure and common items for a total cost of 230 per unit. The level loggers were attached to bridges over three subject streams. A local technician visits the sites monthly to download data, replace the rechargeable batteries, and take a manual water level

  5. Epigenetic targeting in acute myeloid leukemia: use of flow cytometry in monitoring therapeutic effects.

    Science.gov (United States)

    Ryningen, Anita; Bruserud, Øystein

    2007-12-01

    Flow cytometric techniques have emerged as a powerful tool in hematology allowing fast, sensitive and reproducible multi-parametric analyses at the single cell level of heterogeneous samples. Small subsets of cells can be studied with high degree of accuracy, and a broad and constantly increasing specter of antibodies is available. Flow cytometry has therefore become the method of choice for evaluation of therapeutic effects at single cell level. These methodological approaches can easily be used to study hematological malignancies, and the future use of this strategy in other malignancies will depend on the development of laboratory techniques to prepare suspensions of viable cells also from tumor biopsies. The selection of biological parameters for evaluation of treatment effects should probably be based on (i) molecular markers involved in cancer-associated genetic abnormalities; (ii) other molecular markers showing altered expression in the malignant cells and thought to be involved in leukemogenesis or having a prognostic impact; (ii) functional assays known to reflect biological characteristics that are important in carcinogenesis (e.g. cell cycle distribution, functional evaluation of apoptosis regulation). These molecules will in addition often represent the therapeutic targets when new anticancer drugs are developed. In this review we use treatment of acute myeloid leukemia with histone deacetylase inhibitors as an example. Based on the criteria mentioned above we suggest that the monitoring of therapeutic effects on the cancer cells in these patients should include differentiation status, histone acetylation, cell cycle distribution, pro- and anti-apoptotic signaling balance and intracellular levels of various transcription factors.

  6. Method and apparatus for monitoring the flow of mercury in a system

    Science.gov (United States)

    Grossman, M.W.

    1987-12-15

    An apparatus and method for monitoring the flow of mercury in a system are disclosed. The equipment enables the entrainment of the mercury in a carrier gas e.g., an inert gas, which passes as mercury vapor between a pair of optically transparent windows. The attenuation of the emission is indicative of the quantity of mercury (and its isotopes) in the system. A 253.7 nm light is shone through one of the windows and the unabsorbed light is detected through the other window. The absorption of the 253.7 nm light is thereby measured whereby the quantity of mercury passing between the windows can be determined. The apparatus includes an in-line sensor for measuring the quantity of mercury. It includes a conduit together with a pair of apertures disposed in a face to face relationship and arranged on opposite sides of the conduit. A pair of optically transparent windows are disposed upon a pair of viewing tubes. A portion of each of the tubes is disposed inside of the conduit and within each of the apertures. The two windows are disposed in a face to face relationship on the ends of the viewing tubes and the entire assembly is hermetically sealed from the atmosphere whereby when 253.7 nm ultraviolet light is shone through one of the windows and detected through the other, the quantity of mercury which is passing by can be continuously monitored due to absorption which is indicated by attenuation of the amplitude of the observed emission. 4 figs.

  7. Interacting Blends of Novel Unsaturated Polyester Amide Resin with Styrene

    Directory of Open Access Journals (Sweden)

    Hasmukh S. Patel

    2004-01-01

    Full Text Available Novel unsaturated poly (ester-amide resins (UPEAs were prepared by the reaction between an epoxy resin, namely diglycidyl ether of bisphenol–A (DGEBA and unsaturated aliphatic bisamic acids using a base catalyst. These UPEAs were then blended with a vinyl monomer namely, Styrene (STY. to produce a homogeneous resin syrup. The curing of these UPEAs-STY. resin blends was carried out by using benzoyl peroxide (BPO as a catalyst and was monitored by using a differential scanning calorimeter (DSC. The glass fibre reinforced composites (i.e. laminates of these UPEA-STY. resin blends were fabricated using the DSC data. The chemical, mechanical and electrical properties of the glass fibre composites have also been evaluated. The unreinforced cured samples of the UPEA-STY. resin blends were also analyzed by thermogravimetry (TGA.

  8. Hazard assessment of the Gschliefgraben earth flow (Austria) based on monitoring data and evolution modelling

    Science.gov (United States)

    Poisel, R.; Preh, A.; Hofmann, R.; Schiffer, M.; Sausgruber, Th.

    2009-04-01

    A rock slide on to the clayey - silty - sandy - pebbly masses in the Gschliefgraben (Upper Austria province, Lake Traunsee) having occurred in 2006 as well as the humid autumn of 2007 triggered an earth flow comprising a volume up to 5 mill m³ and moving with a maximum displacement velocity of 5 m/day during the winter of 2007-2008. The possible damage was estimated up to 60 mill € due to possible destruction of houses and of a road to a settlement with heavy tourism. Exploratory drillings revealed that the moving mass consists of an alternate bedding of thicker, less permeable clayey - silty layers and thinner, more permeable silty - sandy - pebbly layers. The movement front ran ahead in the creek bed. Therefore it was assumed that water played an important role and the earth flow moved due to soaking of water into the ground from the area of the rock slide downslope. Inclinometer measurements showed that the uppermost, less permeable layer was sliding on a thin, more permeable layer. The movement process was analysed by numerical models (FLAC) and by conventional calculations in order to assess the hazard. The coupled flow and mechanical models showed that sections of the less permeable layer soaked with water were sliding on the thin, more permeable layer due to excessive watering out of the more permeable layer. These sections were thrust over the downward lying, less soaked areas, therefore having higher strength. The material thrust over the downward lying, less soaked areas together with the moving front of pore water pressures caused the downward material to fail and to be thrust over the downslope lying material in a distance of some 50 m. Thus a cyclic process was created without any indication of a sudden sliding of the complete less permeable layer. Nevertheless, the inhabitants of 15 houses had to be evacuated for safety reasons. They could return to their homes after displacement velocities had decreased. Displacement monitoring by GPS showed that

  9. A low cost strategy to monitor the expansion and contraction of the flowing stream network in mountainous headwater catchments

    Science.gov (United States)

    Assendelft, Rick; van Meerveld, Ilja; Seibert, Jan

    2017-04-01

    Streams are dynamic features in the landscape. The flowing stream network expands and contracts, connects and disconnects in response to rainfall events and seasonal changes in catchment wetness. Sections of the river system that experience these wet and dry cycles are often referred to as temporary streams. Temporary streams are abundant and widely distributed freshwater ecosystems. They account for more than half of the total length of the global stream network, are unique habitats and form important hydrological and ecological links between the uplands and perennial streams. However, temporary streams have been largely unstudied, especially in mountainous headwater catchments. The dynamic character of these systems makes it difficult to monitor them. We describe a low-cost, do-it-yourself strategy to monitor the occurrence of water and flow in temporary streams. We evaluate this strategy in two headwater catchments in Switzerland. The low cost sensor network consists of electrical resistivity sensors, water level switches, temperature sensors and flow sensors. These sensors are connected to Arduino microcontrollers and data loggers, which log the data every 5 minutes. The data from the measurement network are compared with observations (mapping of the temporary stream network) as well as time lapse camera data to evaluate the performance of the sensors. We look at how frequently the output of the sensors (presence and absence of water from the ER and water level data, and flow or no-flow from the flow sensors) corresponds to the observed channel state. This is done for each sensor, per sub-catchment, per precipitation event and per sensor location to determine the best sensor combination to monitor temporary streams in mountainous catchments and in which situation which sensor combination works best. The preliminary results show that the sensors and monitoring network work well. The data from the sensors corresponds with the observations and provides information

  10. Noninvasive quantitative measurement of cerebral blood flow with [sup 123]I-IMP; Lung monitoring method

    Energy Technology Data Exchange (ETDEWEB)

    Oguchi, Kazuhiro; Kasuga, Toshio; Sone, Shusuke; Nakanishi, Fumiko; Ito, Atsuko (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine); Tanizaki, Yoshio

    1993-06-01

    In order to perform a less invasive determination of regional cerebral blood flow (rCBF) using N-isopropyl-p-[[sup 123]I] iodoamphetamine (I-123-IMP), we used the lung clearance curve as a substitute for the arterial blood activity curve as an input function. We assumed that a major portion of the intravenously injected I-123-IMP initially accumulates in the lung and then is gradually cleared from the lung pool to enter the systemic circulation. In this case lung clearance could be considered nearly equal to the integral of arterial blood activity shown during the examination. We used a single probe detector to obtain the lung clearance curve as the difference between sequential lung activity and peak lung activity. The absolute value of the sequential change in arterial blood activity was estimated from the differentiated lung clearance curve compared with the arterial blood activity that was estimated by actual blood sampling once during the examination. The rCBF was calculated by the thus estimated arterial blood activity curve and brain activity by SPECT image using the microsphere model. The values of rCBF obtained by this method were similar to those obtained by the continuous arterial sampling method, and this lung monitoring method was thought to be applicable to clinical use. (author).

  11. Interacting Blends of Novel Unsaturated Polyester Amide Resin with Vinyl Acetate

    OpenAIRE

    Patel, H. S.; Panchal, K. K.; Patel, S. R.; Desai, S. N.

    2004-01-01

    Novel unsaturated poly (ester- amide) resins (UPEAs) were prepared by the reaction between an epoxy resin, namely diglycidyl ether of bisphenol–A (DGEBA) and unsaturated aliphatic bisamic acids using a base catalyst. These UPEAs were then blended with a vinyl monomer namely, Vinyl acetate (VA) to produce a homogeneous resin syrup. The curing of these UPEAs-VA resin blends was carried out by using benzoyl peroxide (BPO) as an initiator for the radical polymerization and was monitored by using ...

  12. Mechanistic understanding of fouling of protein A chromatography resin.

    Science.gov (United States)

    Pathak, Mili; Rathore, Anurag S

    2016-08-12

    This paper aims to provide a thorough understanding of how fouling of Protein A resin takes place. Binding and mass transport properties of widely used agarose-based Protein A resin, MabSelect SuRe™, have been examined to understand the mechanism of resin fouling. There could be various factors that impact resin fouling. These include product/impurity build-up due to components in the feed material and ligand degradation due to the use of harsh buffers. To unravel their contributions, cycling studies were performed with and without product loading. The results presented in this paper provide a lucid understanding of the causative factors that limit Protein A chromatographic resin lifetime. The capacity fall for protein A resin at the end of 100th cycle due to use of feed material was found to be five times greater than that without using feed material. Compared to the fresh resin, the cycled resin samples shows 24% reduction in particle porosity and 51% reduction in pore mass transfer coefficient. Transmission electron microscopy (TEM) was used to qualitatively monitor accumulation of foulants on the cycled resin. Fouled resin sample contained a dense residue in the interior and exterior of resin particle both as a film at the bead surface and as granules. The surface activation energy increased five times in the case of fouled resin sample. The major event in fouling was identified as the non-specific adsorption of the feed material components on resin, signaling that pore diffusion is the rate limiting step. It is anticipated that these findings will assist in development of a more robust and economical downstream manufacturing process for monoclonal antibody purification. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. D.C.-electrical conductivity as a method for monitoring radiation curing of unsaturated polyester resins. Pt. 2: Influence of electrical field and dose rate

    International Nuclear Information System (INIS)

    Pucic, I.; Ranogajec, F.

    1996-01-01

    The course of radiation cross linking of unsaturated polyester resins was followed by measuring electrical conductivity change. Both the electrical field strength and dose rate influenced the crosslinking. The electrical field somewhat increased the reaction rate possibly due to the orientation of a polar polyester chains. To investigate the effect of electrical field, the samples were irradiated to different doses at different field strengths, from 2.5 to 250 kV/m and then extracted in benzene to determine the extent of crosslinking. The extraction analysis of irradiated samples confirmed the influence of electrical field observed in conductivity measurements. The electrical field effect depended on the dose rate. Three dose rates were applied 3.05, 0.354 and 0.096 kGy/h. The medium dose rate gave the highest reaction rate (on dose scale). Faster decrease of free styrene content with radiation dose than increase of gel content at higher dose rate implies partial styrene grafting or homopolymerization. The higher the electrical field, the more pronounced were the effects of dose rate. (Author)

  14. Ultrasound-Doppler technique for monitoring blood flow in the brachial artery compared with occlusion plethysmography of the forearm.

    Science.gov (United States)

    Byström, S; Jensen, B; Jensen-Urstad, M; Lindblad, L E; Kilbom, A

    1998-11-01

    Blood flow changes in the brachial artery of seven subjects during and after submaximal static handgrip contractions were measured by duplex Doppler ultrasound technique. These measurements were compared with the results of occlusion plethysmography, measured immediately (2-3 heartbeats) after. For the combined data from all measurements, a common calibration line could be drawn (linear regression, r=0.92). The flow measurements from the two methods were tested by a four-way analysis of variance and there was no significant difference between the methods during (static) exercise, indicating acceptable coherence. Occlusion plethysmography may well be used for monitoring forearm blood flow during conditions of static exercise. In addition, the cuff occlusion pressure of the plethysmograph (50 mmHg) decreased the blood flow of the brachial artery by approximately 28% as measured by duplex Doppler ultrasound.

  15. Application of an optimized flow cytometry-based quantification of Platelet Activation (PACT: Monitoring platelet activation in platelet concentrates.

    Directory of Open Access Journals (Sweden)

    Cécile H Kicken

    Full Text Available Previous studies have shown that flow cytometry is a reliable test to quantify platelet function in stored platelet concentrates (PC. It is thought that flow cytometry is laborious and hence expensive. We have optimized the flow cytometry-based quantification of agonist induced platelet activation (PACT to a labor, time and more cost-efficient test. Currently the quality of PCs is only monitored by visual inspection, because available assays are unreliable or too laborious for use in a clinical transfusion laboratory. Therefore, the PACT was applied to monitor PC activation during storage.The optimized PACT was used to monitor 5 PCs during 10 days of storage. In brief, optimized PACT uses a ready-to-use reaction mix, which is stable at -20°C. When needed, a test strip is thawed and platelet activation is initiated by mixing PC with PACT. PACT was based on the following agonists: adenosine diphosphate (ADP, collagen-related peptide (CRP and thrombin receptor-activating peptide (TRAP-6. Platelet activation was measured as P-selectin expression. Light transmission aggregometry (LTA was performed as a reference.Both PACT and LTA showed platelet function decline during 10-day storage after stimulation with ADP and collagen/CRP; furthermore, PACT showed decreasing TRAP-induced activation. Major differences between the two tests are that PACT is able to measure the status of platelets in the absence of agonists, and it can differentiate between the number of activated platelets and the amount of activation, whereas LTA only measures aggregation in response to an agonist. Also, PACT is more time-efficient compared to LTA and allows high-throughput analysis.PACT is an optimized platelet function test that can be used to monitor the activation of PCs. PACT has the same accuracy as LTA with regard to monitoring PCs, but it is superior to both LTA and conventional flow cytometry based tests with regard to labor-, time- and cost efficiency.

  16. Coupling ground penetrating radar and fluid flow modeling for oilfield monitoring applications

    NARCIS (Netherlands)

    Miorali, M.; Zhou, F.; Slob, E.C.; Arts, R.

    2011-01-01

    The recent introduction of smart well technology allows for new geophysical monitoring opportunities. Smart wells, which allow zonal production control, combined with monitoring techniques capable of capturing the arrival of undesired fluids, have the potential to significantly increase the oil

  17. Monitoring water flows with time-lapse Electrical Resistivity Tomography on the Super-Sauze landslide

    Science.gov (United States)

    Gance, J.; Sailhac, P.; Malet, J.-P.; Grandjean, G.; Supper, R.; Jochum, B.; Ottowitz, D.

    2012-04-01

    This work presents results of a permanent hydro-geophysical monitoring of an active landslide developed in clay-shales. Hydrology has been proved to be a major factor controlling the Super-Sauze earthflow behavior, but it knowledge still limited mainly because of the importance of spatial heterogeneities. The geometry of the bedrock creates internal crests and gullies that can guide waterflows or create a lock and engender an excess of pore water pressure; the soil surface characteristics plays also a large role in the surface hydraulic conductivity, and therefore, on the infiltration pattern. To understand in detail these processes, it is therefore important to monitor spatially at large scale (with high resolution) those phenomena and to overcome the monitoring difficulties inherent to a fast-moving clayey earthflow. The objectives of the survey are to identify and characterize spatially and temporarily the water flow circulation within the landslide body over a period of one year. The studied profile measures 114 m long and is surveyed with 93 electrodes spaced from 0.5, 1 or 2 meter according the soil surface cracking. Four resistivity datasets of 4300 measurements are acquired each day using a gradient array since May 2011. The monitoring is performed with the GEOMON4D system, developed by the Geological Survey of Austria. To facilitate the interpretation, humidity, conductivity, temperature, and piezometer sensors are placed along the profile. Two dGPS antenna placed upstream and downstream the profile allow to correlate the results with soil displacement. Lefranc tests and granulometry results realized on several samples have shown the important heterogeneities of the near surface. The objective of this work is to present the data processing strategy for the analysis of long periods time-lapse ERT survey of natural rain events taking into account changes through time of the position of the electrodes, changes in the soil surface state and important changes

  18. Reduction of polyester resin shrinkage by means of epoxy resin

    International Nuclear Information System (INIS)

    Pietrzak, M.; Brzostowski, A.

    1981-01-01

    An attempt was made to decrease the shrinkage of unsaturated polyester resin, taking place during radiation-induced curing, by the addition of epoxy resin. In order to combine chemically both resins, the epoxy component was modified with cinnamic and acrylic acids. A composition of 90 parts of polyester resin, 10 parts of epoxy resin modified with cinnamic acid, and 150 parts of a silica filler showed a volume shrinkage of 1.2%. (author)

  19. Correlations of norbornenyl crosslinked polyimide resin structures with resin thermo-oxidative stability, resin glass transition temperature and composite initial mechanical properties

    Science.gov (United States)

    Alston, William B.

    1988-01-01

    PMR (polymerization of monomeric reactants) methodology was used to prepare 70 different polyimide oligomeric resins and 30 different unidirectional graphite fiber/polyimide composites. Monomeric composition as well as chain length between sites of crosslinks were varied to examine their effects on resin thermo-oxidative stability and glass transition temperature (Tg) of the cured/postcured resins. A linear correlation of decreasing 316 C resin weight loss/surface area versus (1) decreasing aliphatic content, or (2) increasing benzylic/aliphatic content stoichiometry ratio over a wide range of resin compositions was observed. An almost linear correlation of Tg versus molecular distance between the crosslinks was also observed. An attempt was made to correlate Tg with initial composite mechanical properties (flexural strength and interlaminar shear strength). However, the scatter in mechanical strength data prevented obtaining a clear correlation. Instead, only a range of composite mechanical properties was obtained at 25, 288, and 316 C. Perhaps more importantly, what did become apparent during the correlation study was (1) the PMR methodology could be used to prepare composites from resins containing a wide variety of monomer modifications, (2) that these composites almost invariably provided satisfactory initial mechanical properties as long as the resins formulated exhibited satisfactory processing flow, and (3) that PMR resins exhibited predictable rates of 316 C weight loss/surface area based on their benzylic/aliphatic stoichiometery ratio.

  20. Improved detection of incipient anomalies via multivariate memory monitoring charts: Application to an air flow heating system

    KAUST Repository

    Harrou, Fouzi

    2016-08-11

    Detecting anomalies is important for reliable operation of several engineering systems. Multivariate statistical monitoring charts are an efficient tool for checking the quality of a process by identifying abnormalities. Principal component analysis (PCA) was shown effective in monitoring processes with highly correlated data. Traditional PCA-based methods, nevertheless, often are relatively inefficient at detecting incipient anomalies. Here, we propose a statistical approach that exploits the advantages of PCA and those of multivariate memory monitoring schemes, like the multivariate cumulative sum (MCUSUM) and multivariate exponentially weighted moving average (MEWMA) monitoring schemes to better detect incipient anomalies. Memory monitoring charts are sensitive to incipient anomalies in process mean, which significantly improve the performance of PCA method and enlarge its profitability, and to utilize these improvements in various applications. The performance of PCA-based MEWMA and MCUSUM control techniques are demonstrated and compared with traditional PCA-based monitoring methods. Using practical data gathered from a heating air-flow system, we demonstrate the greater sensitivity and efficiency of the developed method over the traditional PCA-based methods. Results indicate that the proposed techniques have potential for detecting incipient anomalies in multivariate data. © 2016 Elsevier Ltd

  1. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  2. Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments

    OpenAIRE

    Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan

    2015-01-01

    Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000?). Mesial and distal 1/3 parts of the res...

  3. Laser speckle contrast imaging for monitoring changes in microvascular blood flow

    DEFF Research Database (Denmark)

    Ambrus, Rikard; Strandby, Rune B.; Svendsen, Lars Bo

    2016-01-01

    BACKGROUND/AIMS: Microvascular blood flow is essential for healing and predicts surgical outcome. The aim of the current study was to investigate the relation between fluxes measured with the laser speckle contrast imaging (LSCI) technique and changes in absolute blood flow. In addition, we studied...

  4. Instrumentation to Monitor Transient Periodic Developing Flow in Non-Newtonian Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Bamberger, Judith A.; Enderlin, Carl W.

    2013-11-15

    Staff at Pacific Northwest National Laboratory have conducted mixing and mobilization experiments with non-Newtonian slurries that exhibit Bingham plastic and shear thinning behavior and shear strength. This paper describes measurement techniques applied to identify the interface between flowing and stationary regions of non-Newtonian slurries that are subjected to transient, periodic, developing flows. Techniques were developed to identify the boundary between the flowing and stationary regions, time to mix, characteristic velocities of the flow field produced by the symmetrically spaced nozzles, and the velocity of the upwell formed in the center of the tank by the intersection of flow from four symmetrically spaced nozzles that impinge upon the tank floor. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents and to determine mixing times for process evaluation.

  5. Long-term ground penetrating radar monitoring of a small volume DNAPL release in a natural groundwater flow field

    Science.gov (United States)

    Hwang, Yong Keun; Endres, Anthony L.; Piggott, Scott D.; Parker, Beth L.

    2008-04-01

    An earlier field experiment at Canadian Forces Base Borden by Brewster and Annan [Geophysics 59 (1994) 1211] clearly demonstrated the capability of ground penetrating radar (GPR) reflection profiling to detect and monitor the formation of DNAPL layers in the subsurface. Their experiment involved a large volume release (770 L) of tetrachloroethylene into a portion of the sand aquifer that was hydraulically isolated from groundwater flow by sheet pile walls. In this study, we evaluated the ability of GPR profiling to detect and monitor much smaller volume releases (50 L). No subsurface confining structure was used in this experiment; hence, the DNAPL impacted zone was subjected to the natural groundwater flow regime. This condition allowed us to geophysically monitor the DNAPL mass loss over a 66 month period. Reflectivity variations on the GPR profiles were used to infer the presence and evolution of the solvent layers. GPR imaging found significant reflectivity increases due to solvent layer formation during the two week period immediately after the release. These results demonstrated the capacity of GPR profiling for the detection and monitoring of lesser volume DNAPL releases that are more representative of small-scale industrial spills. The GPR imaged solvent layers subsequently reduced in both areal extent and reflectivity after 29 months and almost completely disappeared by the end of the 66 month monitoring period. Total DNAPL mass estimates based on GPR profiling data indicated that the solvent mass was reduced to 34%-36% of its maximum value after 29 months; only 4%-9% of the solvent mass remained in the study area after 66 months. These results are consistent with independent hydrogeological estimates of remaining DNAPL mass based on the downgradient monitoring of the dissolved solvent phase. Hence, we have concluded that the long-term GPR reflectivity changes of the DNAPL layers are likely the result from the dissolution of chlorinated solvents residing

  6. Modeling flow through the sand pack: implications for groundwater sampling from multi- level monitoring wells in fractured bedrock aquifers.

    Science.gov (United States)

    Kozuskanich, J.; Novakowski, K.; Anderson, B.

    2009-05-01

    Multi-level piezometers are often used in groundwater studies to monitor multiple zones within a single borehole. In the fractured rock setting the monitoring intervals are typically designed to isolate discrete fracture features (single fractures or fracture zones). This can be very useful for determining vertical connectivity and the distribution of a contaminant within a fractured rock aquifer. A simple and inexpensive method for completing a bedrock borehole as a multi-level piezometer is to use PVC screen and riser, a sand pack around the screened section, and bentonite to isolate each interval. Flow into the borehole is dominantly confined to the intersecting discrete fracture features. The objective of this study is to examine the nature of the flow through the sand pack and screen slots as water travels from the fracture to the pump intake under pumping conditions. Our conceptual model suggests only a portion of the sand pack in the vicinity of the fractures should be hydraulically active in this scenario. Thus, portions of the wellbore may remain stagnant during pumping depending on the location of the pump intake with respect to the fractures. Flow paths in the sand pack may be controlled by the relationship between the transmissivity of the fracture and screen slots. HydroGeoSphere, a numerical model for flow and solute transport in discrete fractures and porous media, will be used to validate the conceptual model and define the head and velocity profiles in a multi-level interval under various pumping rate and discrete fracture aperture scenarios. The results of this study could have implications for defining a "well volume" in sampling protocols designed for multi-level piezometers in bedrock aquifer systems. The results may also be a useful tool for interpreting the significance of the sand pack as a source of bacteria in water quality monitoring studies that use multi-level piezometer construction of this sort.

  7. Note: Real-time monitoring via second-harmonic interferometry of a flow gas cell for laser wakefield acceleration.

    Science.gov (United States)

    Brandi, F; Giammanco, F; Conti, F; Sylla, F; Lambert, G; Gizzi, L A

    2016-08-01

    The use of a gas cell as a target for laser wakefield acceleration (LWFA) offers the possibility to obtain stable and manageable laser-plasma interaction process, a mandatory condition for practical applications of this emerging technique, especially in multi-stage accelerators. In order to obtain full control of the gas particle number density in the interaction region, thus allowing for a long term stable and manageable LWFA, real-time monitoring is necessary. In fact, the ideal gas law cannot be used to estimate the particle density inside the flow cell based on the preset backing pressure and the room temperature because the gas flow depends on several factors like tubing, regulators, and valves in the gas supply system, as well as vacuum chamber volume and vacuum pump speed/throughput. Here, second-harmonic interferometry is applied to measure the particle number density inside a flow gas cell designed for LWFA. The results demonstrate that real-time monitoring is achieved and that using low backing pressure gas (<1 bar) and different cell orifice diameters (<2 mm) it is possible to finely tune the number density up to the 10(19) cm(-3) range well suited for LWFA.

  8. Note: Real-time monitoring via second-harmonic interferometry of a flow gas cell for laser wakefield acceleration

    Science.gov (United States)

    Brandi, F.; Giammanco, F.; Conti, F.; Sylla, F.; Lambert, G.; Gizzi, L. A.

    2016-08-01

    The use of a gas cell as a target for laser wakefield acceleration (LWFA) offers the possibility to obtain stable and manageable laser-plasma interaction process, a mandatory condition for practical applications of this emerging technique, especially in multi-stage accelerators. In order to obtain full control of the gas particle number density in the interaction region, thus allowing for a long term stable and manageable LWFA, real-time monitoring is necessary. In fact, the ideal gas law cannot be used to estimate the particle density inside the flow cell based on the preset backing pressure and the room temperature because the gas flow depends on several factors like tubing, regulators, and valves in the gas supply system, as well as vacuum chamber volume and vacuum pump speed/throughput. Here, second-harmonic interferometry is applied to measure the particle number density inside a flow gas cell designed for LWFA. The results demonstrate that real-time monitoring is achieved and that using low backing pressure gas (<1 bar) and different cell orifice diameters (<2 mm) it is possible to finely tune the number density up to the 1019 cm-3 range well suited for LWFA.

  9. Coordinated Sampling: An Efficient, Network-Wide Approach for Flow Monitoring

    National Research Council Canada - National Science Library

    Sekar, Vyas; Reiter, Michael K; Willinger, Walter; Zhang, Hui

    2007-01-01

    .... We demonstrate that Coordinated Sampling presents an attractive solution for ISPs. First, it more than doubles flow coverage to support security applications and does so without compromising the accuracy of traditional traffic engineering applications...

  10. Fiber Optic Mass Flow Gauge for Liquid Cryogenic Fuel Facilities Monitoring and Control, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I proposal describes a fiber optic mass flow gauge that will aid in managing liquid hydrogen and oxygen fuel storage and transport. The increasing...

  11. Flow

    DEFF Research Database (Denmark)

    Knoop, Hans Henrik

    2006-01-01

    FLOW. Orden i hovedet på den fede måde Oplevelsesmæssigt er flow-tilstanden kendetegnet ved at man er fuldstændig involveret, fokuseret og koncentreret; at man oplever stor indre klarhed ved at vide hvad der skal gøres, og i hvilket omfang det lykkes; at man ved at det er muligt at løse opgaven...

  12. Real-Time Optical Monitoring of Flow Kinetics and Gas Phase Reactions Under High-Pressure OMCVD Conditions

    Science.gov (United States)

    Dietz, N.; McCall, S.; Bachmann, K. J.

    2001-01-01

    This contribution addresses the real-time optical characterization of gas flow and gas phase reactions as they play a crucial role for chemical vapor phase depositions utilizing elevated and high pressure chemical vapor deposition (HPCVD) conditions. The objectives of these experiments are to validate on the basis of results on real-time optical diagnostics process models simulation codes, and provide input parameter sets needed for analysis and control of chemical vapor deposition at elevated pressures. Access to microgravity is required to retain high pressure conditions of laminar flow, which is essential for successful acquisition and interpretation of the optical data. In this contribution, we describe the design and construction of the HPCVD system, which include access ports for various optical methods of real-time process monitoring and to analyze the initial stages of heteroepitaxy and steady-state growth in the different pressure ranges. To analyze the onset of turbulence, provisions are made for implementation of experimental methods for in-situ characterization of the nature of flow. This knowledge will be the basis for the design definition of experiments under microgravity, where gas flow conditions, gas phase and surface chemistry, might be analyzed by remote controlled real-time diagnostics tools, developed in this research project.

  13. The monitoring of methane fermentation in sequencing batch bioreactor with flow-through array of miniaturized solid state electrodes.

    Science.gov (United States)

    Buczkowska, Agnieszka; Witkowska, Emilia; Górski, Lukasz; Zamojska, Anna; Szewczyk, Krzysztof W; Wróblewski, Wojciech; Ciosek, Patrycja

    2010-06-15

    Electronic tongues (ETs) based on potentiometric sensor arrays are often used for foodstuff classification, origin recognition, estimation of complex samples' properties, etc. In the last few years they were also applied for various fermentation monitoring, such as Aspergillus niger fermentation, light cheese production, batch Escherichia coli fermentation, as a devices capable of fast, inexpensive, automated and on-line control of the process. In this work a novel application for ET is proposed-flow-through array of solid state electrodes was used for the analysis of samples obtained during methane fermentation (anaerobic digestion) of whey in sequencing batch bioreactor, according to their volatile fatty acid (VFA) content and chemical oxygen demand (COD).

  14. Raspberry Pi in-situ network monitoring system of groundwater flow and temperature integrated with OpenGeoSys

    Science.gov (United States)

    Park, Chan-Hee; Lee, Cholwoo

    2016-04-01

    Raspberry Pi series is a low cost, smaller than credit-card sized computers that various operating systems such as linux and recently even Windows 10 are ported to run on. Thanks to massive production and rapid technology development, the price of various sensors that can be attached to Raspberry Pi has been dropping at an increasing speed. Therefore, the device can be an economic choice as a small portable computer to monitor temporal hydrogeological data in fields. In this study, we present a Raspberry Pi system that measures a flow rate, and temperature of groundwater at sites, stores them into mysql database, and produces interactive figures and tables such as google charts online or bokeh offline for further monitoring and analysis. Since all the data are to be monitored on internet, any computers or mobile devices can be good monitoring tools at convenience. The measured data are further integrated with OpenGeoSys, one of the hydrogeological models that is also ported to the Raspberry Pi series. This leads onsite hydrogeological modeling fed by temporal sensor data to meet various needs.

  15. A Simple and Sensitive Flow Injection Optical Fibre Biosensor Based on Immobilised Enzyme for Monitoring of Pesticides

    Directory of Open Access Journals (Sweden)

    B. Kuswandi

    2007-02-01

    Full Text Available A simple and sensitive flow injection optical fibre biosensor based on immobilised enzyme for monitoring of pesticides has been developed. The optical fibre biosensor consists of immobilised acethylcholinesterase (AChE coupled with commercial pH indicator strip. The biosensing process involves the inhibition of AChE by pesticides, where the pH change has been monitored via a pH indicator strip as an optical transducer. The enzyme as a bio-recognition element has been immobilised onto solid-support material (i.e. covalently bond onto preactivated isothiocyanate glass, ICG and then packed in a thermostatic bioreactor connected to the flow-cell that contains pH indicator strip. In the presence of a constant AChE, a colour of the pH layer change and the measured reflected signal could be related to the pesticide concentration in the sample solution. The performance of the flow injection optical biosensor system has been optimized, including chemical and physical parameters. The calibration plot of the inhibition for the determination of organophosphate pesticides (dimethoate and carbamate pesticide (propoxur were in the range of 50 to 1000 µg/l for dimethoate and 10 to 100 µg/l for propoxur. The biosensor allows lower detection limits, calculated at I10%, for propoxur (4.9 µg/l than for dimethoate (24 µg/l, and produces highly reproducible response (RSD<1.5% and readily reversible in the case of carbamate pesticide. While in the case of organophosphate, the regeneration has been possible by treatment with hydroxylamine solution. The flow injection optical fibre biosensor system has been successfully applied for the determination of pesticides in the real water samples.

  16. Development of on-line monitoring system for flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, N.Y.; Lee, S.G.; Hwang, I.S.; Kim, J.T.; Luk, V.K.

    2005-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover wide area in the on-line application. We suggested integrated approach to monitor the FAC-susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible, and that cover wide area, since we don't know where the FAC occurs. For this purpose, we introduced wearing rate model, which concentrates on the electrochemical parameters. By the model, we can predict the wearing rate and then can compare the testing result. After we identified feasibility by analytical way, we developed electrochemical sensors for high temperature application, and introduced mechanical monitoring system, which is still under development. To support the validation of the monitored results, we adopted high temperature UT, which shows good resolution in the testing environment. By this way, all the monitored results can be compared in terms of thickness. Validation test shows the feasibility of sensors. To support direct thickness measurement for wide-area, Direct Current Potential Drop method will be researched to integrate to the developed framework. (authors)

  17. Preferential flows and soil moistures on a Benggang slope: Determined by the water and temperature co-monitoring

    Science.gov (United States)

    Tao, Yu; He, Yangbo; Duan, Xiaoqian; Zou, Ziqiang; Lin, Lirong; Chen, Jiazhou

    2017-10-01

    Soil preferential flow (PF) has important effects on rainfall infiltration, moisture distribution, and hydrological and ecological process; but it is very difficult to monitor and characterize on a slope. In this paper, soil water and soil temperature at 20, 40, 60, 80 cm depths in six positions were simultaneously monitored at high frequency to confirm the occurrence of PF at a typical Benggang slope underlain granite residual deposits, and to determine the interaction of soil moisture distribution and Benggang erosion. In the presence of PF, the soil temperature was first (half to one hour) governed by the rainwater temperature, then (more than one hour) governed by the upper soil temperature; in the absence of PF (only matrix flow, MF), the soil temperature was initially governed by the upper soil temperature, then by the rainwater temperature. The results confirmed the water replacement phenomenon in MF, thus it can be distinguished from PF by additional temperature monitoring. It indicates that high frequency moisture and temperature monitoring can determine the occurrence of PF and reveal the soil water movement. The distribution of soil water content and PF on the different positions of the slope showed that a higher frequency of PF resulted in a higher variation of average of water content. The frequency of PF at the lower position can be three times as that of the upper position, therefore, the variation coefficient of soil water content increased from 4.67% to 12.68% at the upper position to 8.18%-33.12% at the lower position, where the Benggang erosion (soil collapse) was more possible. The results suggest strong relationships between PF, soil water variation, and collapse activation near the Benggang wall.

  18. Cerebral Blood Flow Autoregulation in Sepsis for the Intensivist: Why Its Monitoring May Be the Future of Individualized Care.

    Science.gov (United States)

    Goodson, Carrie M; Rosenblatt, Kathryn; Rivera-Lara, Lucia; Nyquist, Paul; Hogue, Charles W

    2018-02-01

    Cerebral blood flow (CBF) autoregulation maintains consistent blood flow across a range of blood pressures (BPs). Sepsis is a common cause of systemic hypotension and cerebral dysfunction. Guidelines for BP management in sepsis are based on historical concepts of CBF autoregulation that have now evolved with the availability of more precise technology for its measurement. In this article, we provide a narrative review of methods of monitoring CBF autoregulation, the cerebral effects of sepsis, and the current knowledge of CBF autoregulation in sepsis. Current guidelines for BP management in sepsis are based on a goal of maintaining mean arterial pressure (MAP) above the lower limit of CBF autoregulation. Bedside tools are now available to monitor CBF autoregulation continuously. These data reveal that individual BP goals determined from CBF autoregulation monitoring are more variable than previously expected. In patients undergoing cardiac surgery with cardiopulmonary bypass, for example, the lower limit of autoregulation varied between a MAP of 40 to 90 mm Hg. Studies of CBF autoregulation in sepsis suggest patients frequently manifest impaired CBF autoregulation, possibly a result of BP below the lower limit of autoregulation, particularly in early sepsis or with sepsis-associated encephalopathy. This suggests that the present consensus guidelines for BP management in sepsis may expose some patients to both cerebral hypoperfusion and cerebral hyperperfusion, potentially resulting in damage to brain parenchyma. The future use of novel techniques to study and clinically monitor CBF autoregulation could provide insight into the cerebral pathophysiology of sepsis and offer more precise treatments that may improve functional and cognitive outcomes for survivors of sepsis.

  19. Fluorescence depolarisation monitoring of liquid flow before and after exiting a slit nozzle

    Energy Technology Data Exchange (ETDEWEB)

    Quintella, C.M.; Musse, A.P.S.; Goncalves, C.C. [Inst. de Quimica, Univ. Federal da Bahia, Campus de Ondina, Salvador, BA (Brazil); McCaffery, A.J. [School of Chemistry, Physics and Environmental Science, Univ. of Sussex, Falmer, Brighton (United Kingdom)

    2003-07-01

    Steady-state fluorescence depolarisation was used to study the hydrodynamics of ethylene glycol flow inside a quartz slit nozzle for 24 mm (Re{proportional_to}200) and outside as a free thin jet, for 14 mm. The polarisation profiles (over 1000 points) allowed direct evaluation of the velocity gradient within the flowing liquid from this molecular-level probe. Inside the nozzle two lateral boundary layers were observed. The velocity profile was flattened, which was attributed to strong chemical interactions with the walls of the cell. Within the jet, four polarisation profile maxima were observed for the first time, corresponding to two internal converging streams. (orig.)

  20. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W [Harrisonville, MO; Hand, Thomas E [Lee's Summit, MO; DeLaurentiis, Gary M [Jamestown, CA

    2008-12-09

    A resin recycling method that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The method includes receiving the resin in container form. The containers are then ground into resin particles. The particles are exposed to a solvent, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. After separating the particles and the resin, a solvent removing agent is used to remove any residual solvent remaining on the resin particles after separation.

  1. Rheology of Polyaniline Dispersions in Acrylic Resin

    OpenAIRE

    PLESU, Nicoleta; LIESCU, Smaranda; ILIA, Gheorghe

    2006-01-01

    Acrylic dispersions based on polyaniline were obtained and characterised. The polyaniline was obtained by chemical polymerisation of aniline in different organic acid containing phosphorous, in the presence of ammonium-peroxidisulphate as oxidant agent. The blends were obtained by mechanical dispersion of polyaniline in commercially available acrylic resin. The flow behaviour of these dispersions at different shear rates was studied. Furthermore, the resulting acrylic dispersions w...

  2. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    2018-01-01

    Background Positron emission tomography (PET) imaging of anaesthetized pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the distribution of several radiotracers. However, the effect of physiological factors regulating...

  3. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    Background: Positron emission tomography (PET) imaging of anaesthetised pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the kinetics of several radiotracers. However, the impact of physiological factors regulating CBF...

  4. CoreFlow: Enriching Bro security events using network traffic monitoring data

    NARCIS (Netherlands)

    Koning, R.; Buraglio, N.; de Laat, C.; Grosso, P.

    Attacks against network infrastructures can be detected by Intrusion Detection Systems (IDS). Still reaction to these events are often limited by the lack of larger contextual information in which they occurred. In this paper we present CoreFlow, a framework for the correlation and enrichment of IDS

  5. Monitoring winter flow conditions on the Ivishak River, Alaska : final report.

    Science.gov (United States)

    2017-09-01

    The Sagavanirktok River, a braided river on the Alaska North Slope, flows adjacent to the trans-Alaska pipeline for approximately 100 miles south of Prudhoe Bay. During an unprecedented flooding event in mid-May 2015, the pipeline was exposed in an a...

  6. Monitoring pig movement at the slaughterhouse using optical flow and modified angular histograms

    DEFF Research Database (Denmark)

    Gronskyte, Ruta; Clemmensen, Line Katrine Harder; Hviid, Marchen Sonja

    2016-01-01

    We analyse the movement of pig herds through video recordings at a slaughterhouse by using statistical analysis of optical flow (OF) patterns. Unlike the previous attempts to analyse pig movement, no markers, trackers nor identification of individual pigs are needed. Our method handles the analysis...

  7. Monitoring nutrient flows and economic performance in African farming systems (NUTMON); I Concepts and methodologies

    NARCIS (Netherlands)

    Jager, de A.; (KARI) Nandwa, S.M.; (KARI) Okoth, P.F.

    1998-01-01

    Nutrient Monitoring (NUTMON) is a multi-disciplinary and multi-scale approach, addressing the problem of soil nutrient depletion, so far mainly in sub-Saharan Africa. It involves and aims, at the various actors influencing soil nutrient management at different levels. A quantitative and qualitative

  8. Assessment of a flow cytometry technique for studying signaling pathways in platelets: Monitoring of VASP phosphorylation in clinical samples

    Directory of Open Access Journals (Sweden)

    N. Mallouk

    2018-07-01

    Full Text Available A recently released kit (PerFix EXPOSE was reported to improve the measurement of the degree of phosphorylation of proteins in leukocytes by flow cytometry. We tested its adaptation for platelets to monitor vasodilator-stimulated phosphoprotein (VASP phosphorylation, which is the basis of a currently used test for the assessment of the pharmacological response to P2Y12 antagonists (PLT VASP/P2Y12. The PerFix EXPOSE kit was compared to the PLT VASP/P2Y12 kit by using blood samples drawn at 24 h post clopidogrel dose from 19 patients hospitalized for a non-cardio-embolic ischemic stroke and treated with clopidogrel monotherapy for at least five days in an observational study. The platelet PerFix method was based on adaptation of the volume of the sample, the centrifugation speed and the incubation temperature. Poor agreement between prevention by adenosine diphosphate (ADP of PGE1-induced cAMP-mediated VASP phosphorylation and ADP induced aggregation assessed by Light Transmittance Aggregometry was found. We found a significant correlation between the PLT VASP/P2Y12 kit and the PerFix EXPOSE kit. The PerFix EXPOSE kit may also be helpful to monitor adverse effects of second-generation tyrosine kinase inhibitors on platelets. Keywords: Platelet signaling, VASP, Flow cytometry, Clopidogrel

  9. Contact allergy to epoxy resin

    DEFF Research Database (Denmark)

    Bangsgaard, Nannie; Thyssen, Jacob Pontoppidan; Menné, Torkil

    2012-01-01

    to epoxy resin remained stable over the study period. Of the patients with an epoxy resin-positive patch test, 71% returned a questionnaire; 95 patients had worked with epoxy resin in the occupational setting, and, of these, one-third did not use protective gloves and only 50.5% (48) had participated...

  10. High Resolution Monitoring of River Bluff Erosion Reveals Failure Mechanisms and Geomorphically Effective Flows

    Directory of Open Access Journals (Sweden)

    Sara Ann Kelly

    2018-03-01

    Full Text Available Using a combination of Structure from Motion and time lapse photogrammetry, we document rapid river bluff erosion occurring in the Greater Blue Earth River (GBER basin, a muddy tributary to the sediment-impaired Minnesota River in south central Minnesota. Our datasets elucidated dominant bluff failure mechanisms and rates of bluff retreat in a transient system responding to ongoing streamflow increases and glacial legacy impacts. Specifically, we document the importance of fluvial scour, freeze–thaw, as well as other drivers of bluff erosion. We find that even small flows, a mere 30% of the two-year recurrence interval flow, are capable of causing bluff erosion. During our study period (2014–2017, the most erosion was associated with two large flood events with 13- and 25-year return periods. However, based on the frequency of floods and magnitude of bluff face erosion associated with floods over the last 78 years, the 1.2-year return interval flood has likely accomplished the most cumulative erosion, and is thus more geomorphically effective than larger magnitude floods. Flows in the GBER basin are nonstationary, increasing across the full range of return intervals. We find that management implications differ considerably depending on whether the bluff erosion-runoff power law exponent, γ, is greater than, equal to, or less than 1. Previous research has recommended installation of water retention sites in tributaries to the Minnesota River in order to reduce flows and sediment loading from river bluffs. Our findings support the notion that water retention would be an effective practice to reduce sediment loading and highlight the importance of managing for both runoff frequency and magnitude.

  11. Time-Lapse Monitoring of Subsurface Fluid Flow using Parsimonious Seismic Interferometry

    KAUST Repository

    Hanafy, Sherif

    2017-04-21

    A typical small-scale seismic survey (such as 240 shot gathers) takes at least 16 working hours to be completed, which is a major obstacle in case of time-lapse monitoring experiments. This is especially true if the subject that needs to be monitored is rapidly changing. In this work, we will discuss how to decrease the recording time from 16 working hours to less than one hour of recording. Here, the virtual data has the same accuracy as the conventional data. We validate the efficacy of parsimonious seismic interferometry with the time-lapse mentoring idea with field examples, where we were able to record 30 different data sets within a 2-hour period. The recorded data are then processed to generate 30 snapshots that shows the spread of water from the ground surface down to a few meters.

  12. GB-InSAR monitoring of slope deformations in a mountainous area affected by debris flow events

    Science.gov (United States)

    Frodella, William; Salvatici, Teresa; Pazzi, Veronica; Morelli, Stefano; Fanti, Riccardo

    2017-10-01

    Diffuse and severe slope instabilities affected the whole Veneto region (north-eastern Italy) between 31 October and 2 November 2010, following a period of heavy and persistent rainfall. In this context, on 4 November 2010 a large detrital mass detached from the cover of the Mt. Rotolon deep-seated gravitational slope deformation (DSGSD), located in the upper Agno River valley, channelizing within the Rotolon Creek riverbed and evolving into a highly mobile debris flow. The latter phenomena damaged many hydraulic works, also threatening bridges, local roads, and the residents of the Maltaure, Turcati, and Parlati villages located along the creek banks and the town of Recoaro Terme. From the beginning of the emergency phase, the civil protection system was activated, involving the National Civil Protection Department, Veneto Region, and local administrations' personnel and technicians, as well as scientific institutions. On 8 December 2010 a local-scale monitoring system, based on a ground-based interferometric synthetic aperture radar (GB-InSAR), was implemented in order to evaluate the slope deformation pattern evolution in correspondence of the debris flow detachment sector, with the final aim of assessing the landslide residual risk and managing the emergency phase. This paper describes the results of a 2-year GB-InSAR monitoring campaign (December 2010-December 2012) and its application for monitoring, mapping, and emergency management activities in order to provide a rapid and easy communication of the results to the involved technicians and civil protection personnel, for a better understanding of the landslide phenomena and the decision-making process in a critical landslide scenario.

  13. Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device.

    Science.gov (United States)

    Hegener, Michael A; Li, Hua; Han, Daewoo; Steckl, Andrew J; Pauletti, Giovanni M

    2017-09-01

    Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.

  14. D and B monitors for Z-vacuum-section power-flow measurements

    International Nuclear Information System (INIS)

    Stygar, W.A.; Spielman, R.B.; Ives, H.C.

    1997-01-01

    The 36-module Z accelerator--designed to drive z-pinch loads at currents up to 20 MA--is contained in a 33-m-diameter tank with oil, water, and vacuum sections. The peak total forward-going power in the 36 water-section bi-plate transmission lines is approximately 63 TW. nine transmission lines deliver power to each of the four vacuum-section levels (referred to as levels A (the uppermost), B, C, and D). New differential D and B monitors were developed for the Z vacuum section. The Ds measure voltage at the insulator stack. The Bs measure current at the stack and in the outer magnetically-insulated transmission lines. Each monitor has two outputs that allow common-mode noise to be canceled to first order. The differential D has one signal and one noise channel; the differential B has two signal channels with opposite polarities. Each of the two B sensors in the differential B monitor has four 3-mm-diameter loops and is encased in copper to reduce flux penetration. For both types of probes, two 2.2-mm-diameter coaxial-cables connect the outputs to a Prodyn balun for common-mode-noise rejection. The cables provide reasonable bandwidth and generate acceptable levels of Compton drive in Z's bremsstrahlung field. A new cavity B is being developed to measure the total Z current 4.3 cm from the axis of the z-pinch load. All of the sensors are calibrated with 2--4% accuracy. The monitor signals are reduced with Barth or Weinschel attenuators, recorded on Tektronix 0.5-ns/sample digitizing oscilloscopes, and software cable compensated and integrated

  15. Differentiation of HL-60 promyelocytic leukemia cells monitored by flow cytometric measurement of nitro blue tetrazolium (NBT) reduction.

    Science.gov (United States)

    Blair, O C; Carbone, R; Sartorelli, A C

    1985-01-01

    Reduction of nitro blue tetrazolium (NBT) to insoluble blue formazan granules occurs during the stimulus-induced respiratory burst of mature granulocytes and is routinely used as an indicator of the extent of granulocytic differentiation of HL-60 acute promyelocytic leukemia cells. In the present study, the differentiation of HL-60 leukemia cells induced by dimethylsulfoxide (DMSO) or retinoic acid was monitored by flow cytometric (FCM) measurement of forward and 90 degree light scatter of NBT treated cells. Two-parameter correlated analysis permitted a distinction between cells with increased forward and decreased 90 degree light scatter (NBT-), and cells with decreased forward and increased 90 degree light scatter (NBT+). Fixation of NBT treated cells with 1% paraformaldehyde facilitated flow cytometric analysis, and allowed differences in NBT reduction to be quantitated. DMSO-induced cells expressed an all-or-none reduction of NBT to formazan, compared with retinoic acid treated cells that exhibited a graded response. Three parameter flow cytometric analysis of HL-60 leukemia cells stained with propidium iodide in combination with NBT allowed the determination of the cell cycle distribution of NBT-treated cells.

  16. Ratiometric analysis of fura red by flow cytometry: a technique for monitoring intracellular calcium flux in primary cell subsets.

    Directory of Open Access Journals (Sweden)

    Emily R Wendt

    Full Text Available Calcium flux is a rapid and sensitive measure of cell activation whose utility could be enhanced with better techniques for data extraction. We describe a technique to monitor calcium flux by flow cytometry, measuring Fura Red calcium dye by ratiometric analysis. This technique has several advantages: 1 using a single calcium dye provides an additional channel for surface marker characterization, 2 allows robust detection of calcium flux by minority cell populations within a heterogeneous population of primary T cells and monocytes 3 can measure total calcium flux and additionally, the proportion of responding cells, 4 can be applied to studying the effects of drug treatment, simultaneously stimulating and monitoring untreated and drug treated cells. Using chemokine receptor activation as an example, we highlight the utility of this assay, demonstrating that only cells expressing a specific chemokine receptor are activated by cognate chemokine ligand. Furthermore, we describe a technique for simultaneously stimulating and monitoring calcium flux in vehicle and drug treated cells, demonstrating the effects of the Gαi inhibitor, pertussis toxin (PTX, on chemokine stimulated calcium flux. The described real time calcium flux assay provides a robust platform for characterizing cell activation within primary cells, and offers a more accurate technique for studying the effect of drug treatment on receptor activation in a heterogeneous population of primary cells.

  17. Continuous on-line hydrogen ion monitoring to study flow dynamics of perifusion systems and cellular metabolism.

    Science.gov (United States)

    Brand, R M; Ghazzi, M N; Rolfes-Curl, A; Cantor, H C; Midgley, A R

    1994-05-01

    Time-dependent concentration profiles of input signals and feedback of metabolic products can strongly influence cellular responsiveness. To study these parameters, we developed a perifusion system that can deliver biological signals to cells with minimal dispersion, monitor real time responses, and remove waste products continuously. By monitoring pH with miniature hydrogen ion-selective electrodes at intervals of 1 s, effects of dispersion, flow rate, pumping system, and changes in cellular metabolism were demonstrated. Dynamic responses of a human cell line to a series of 10-min pulses of the metabolic uncoupler carbonyl cyanide m-chlorophenylhydrazone (CCCP) were monitored. A rapid 1-min increase in acid release occurred on exposure to CCCP, followed by a decrease in acidification and then a gradual return to a baseline slightly more acidic than before administration of CCCP. These observations demonstrate that this perifusion system can reveal small changes in pH (+/- 0.0005 units) induced by metabolic perturbations and has the potential to reveal the dynamics of cellular responsiveness to a wide range of hormonal, metabolic, and other chemical signals.

  18. A Meta-analysis of randomized clinical trials assessing hemodialysis access thrombosis based on access flow monitoring: Where do we stand?

    Science.gov (United States)

    Muchayi, Timothy; Salman, Loay; Tamariz, Leonardo J; Asif, Arif; Rizvi, Abid; Lenz, Oliver; Vazquez-Padron, Roberto I.; Tabbara, Marwan; Contreras, Gabriel

    2015-01-01

    The National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommends the routine use of hemodialysis arteriovenous (AV) access surveillance to detect hemodynamically significant stenoses and appropriately correct them to reduce the incidence of thrombosis and to improve accesses patency rates. Access blood flow monitoring is considered as one of the preferred surveillance method for both AV fistulas (AVF) and AV grafts (AVG); however, published studies have reported conflicting results of its utility that led healthcare professionals to doubt the benefits of this surveillance method. We performed a meta-analysis of the published randomized controlled trials (RCTs) of AV access surveillance using access blood flow monitoring. Our hypothesis was that access blood flow monitoring lowers the risk of AV access thrombosis and that the outcome differs between AVF and AVG. The estimated overall pooled risk ratio (RR) of thrombosis was 0.87 (95% confidence interval [CI], 0.67 to 1.13) favoring access blood flow monitoring. The pooled RR of thrombosis were 0.64 (95% CI, 0.41 to 1.01) and 1.06 (95% CI, 0.77 to 1.46) in the subgroups of only AVF and only AVG, respectively. Our results added to the uncertainty of access blood flow monitoring as a surveillance method of hemodialysis accesses. PMID:25644548

  19. APPLICATION OF SIX-COLOR FLOW CYTOMETRIC ANALYSIS FOR IMMUNE PROFILE MONITORING

    Directory of Open Access Journals (Sweden)

    I. V. Kudryavtsev

    2015-01-01

    Full Text Available The article deals with applications of six-color flow analysis for studying the immune state parameters by means of flow cytometry. Whole blood from healthy donors was stained with combination of monoclonal antibodies, i.e., HLA-DR-FITC, CD16+56-PE, CD4-ECD, CD19-ECD, CD8-PC5.5, CD3-PC7, CD45-APC (Beckman Coulter, USA using a “no-wash” technology. To adjust the photomultiplier (PMT voltage, we used the tubes with each of the tested monoclonal antibodies, PMT voltage was considered optimal when the negative population was located in the middle of the first decade at the logarithmic scale. The compensatory adjustment was performed in automatic mode, using Navios software (Beckman Coulter, USA. We discuss an optimal gating strategy in order to assess the populations of interest: total T cells (CD3+CD19-, T helper cells (CD3+CD4+, cytotoxic T lymphocytes (CD3+CD8+, B cells (CD3-CD19+, NK cells (CD3-CD16+CD56+, NKT cells (CD3+CD16+CD56+, activated T lymphocytes (CD3+HLA-DR+. 

  20. Application of X-Ray Sensors for In-line and Noninvasive Monitoring of Mass Flow Rate in Continuous Tablet Manufacturing.

    Science.gov (United States)

    Ganesh, Sudarshan; Troscinski, Rachel; Schmall, Nicholas; Lim, Jongmook; Nagy, Zoltan; Reklaitis, Gintaras

    2017-12-01

    The progress in continuous downstream manufacturing of oral solid doses demands effective real-time process management, with monitoring at its core. This study evaluates the feasibility of using a commercial sensor to measure the mass flow rate of the particulates, a critical process variable in continuous manufacturing. The sensor independently measures X-ray attenuation and cross-correlation velocimetry of particulate flow in real time. Steady-state flow rates of blends comprised primarily of acetaminophen and microcrystalline-cellulose are monitored using the sensor, with simultaneous weighing scale measurements, to calibrate the sensor and investigate the measurement accuracy. The free-fall flow measurement of the powder and granule blends in a conduit is linearly proportional to the X-ray attenuation. Relative standard deviations of ∼3%-7% for 1 s monitoring are observed and a measurement error of approximately 5% suggests the usability of the sensor for real-time monitoring. The sensor measurement is robust for operational variations in composition, addition of lubricant or glidant and reuse of material for PAT tool calibration. The measurement relative standard deviations depend on particulate flow dynamics at the sensor location. This requires experimental evaluation for a given material at the sensor location, to capture the flow dynamics of the particulate stream through the sensor. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  1. Depth of cure of bulk-fill flowable composite resins.

    Science.gov (United States)

    Pedalino, Inaam; Hartup, Grant R; Vandewalle, Kraig S

    2015-01-01

    In recent years, manufacturers have introduced flowable composite resins that reportedly can be placed in increments of 4 mm or greater. The purpose of this study was to evaluate the depth of cure of bulk-fill flowable composite resins (SureFil SDR Flow, Grandio Flow, and Venus Bulk Fill) and a conventional flowable composite resin (Revolution Formula 2). Depth of cure was measured in terms of bottom-maximum Knoop hardness number (KHN) ratios and the International Organization for Standardization (ISO) 4049 scrape technique. Shades A2 and A3 of SureFil SDR Flow, Grandio Flow, and Revolution Formula 2 were tested. Venus Bulk Fill was tested in its only available shade (universal). Specimens in thicknesses of 2, 3, 4, 5, and 6 mm were polymerized for 20 or 40 seconds, and a hardness tester was used to determine the hardness ratios for each shade at each thickness. For the scraping technique, after specimens were exposed to the curing light, unpolymerized composite resin was removed with a plastic instrument, the polymerized composite was measured, and the length was divided by 2 per ISO guidelines. According to the KHN ratios and the scrape test, Venus Bulk Fill predictably exceeded the manufacturer's claim of a 4-mm depth of cure at both 20 and 40 seconds of curing time. The overall results for depth of cure showed that Venus Bulk Fill ≥ SureFil SDR Flow ≥ Grandio Flow ≥ Revolution Formula 2.

  2. Physical Monitoring of Flow Into and Within Great Salt Lake, Utah

    Science.gov (United States)

    Kenney, T. A.; Naftz, D. L.; Perschon, W. C.

    2006-12-01

    Great Salt Lake (GSL) is the hydrologic terminus for the eastern part of the Great Basin. As the largest inland waterbody in the Western United States, GSL plays a critical ecologic role for many migratory bird species. In terms of harvest quantity and quality, the brine shrimp (Artemia) fishery of GSL is among the strongest in the world. The characteristic of GSL as a hydrologic sink amplifies anthropogenic activities throughout the basin, most specifically activities that occur along its eastern and southern shores, the urban corridor of the Wasatch Front. In 1959 GSL was divided into north and south parts by a rock-fill railroad causeway. Since then, an extreme density gradient between the north and south part exists as a result of limited conveyance of water from the south part where more than 95 percent of the total freshwater input occurs (Loving, and others, 2000). To date, little is known about the loading and cycling of various chemical constituents associated with human activities including nutrients, selenium, and mercury. Hydroacoustic technology, specifically acoustic Doppler technology, is currently being used to obtain a better physical understanding of GSL. Since 1999, stratified bi-directional discharge has been measured at the causeway breach with an acoustic Doppler current profiler. From these measurements, net flow components to the north and south have been used to assess the movement of water and salt through the causeway. Low hydraulic gradients and variable backwater conditions at the two largest inflows to GSL required the deployment of in-situ acoustic Doppler velocity meters to accurately compute continuous discharge, critical for constituent loading analyses. These discharge records, computed using the index velocity method, show sensitivity to large wind events that can lead to a complete reversal of flow. Velocity profiles acquired during two multi-day water-quality synoptic sampling runs with acoustic Doppler current profilers have

  3. Modelling and measurement of wear particle flow in a dual oil filter system for condition monitoring

    DEFF Research Database (Denmark)

    Henneberg, Morten; Eriksen, René Lynge; Fich, Jens

    2016-01-01

    Wear debris is an indicator of the health of machinery, and the availability of accurate methods for characterising debris is important. In this work, a dual filter model for a gear oil system is used in conjunction with operational data to indicate three different system operating states...... boundary condition for particle burst phenomenon, the release of wear particles from a pleated mesh filter is measured in a test rig and included in the model. The findings show that a dual filter model, with startup phenomenon included, can describe trends in the wear particle flow observed in the gear...... oil. Using this model it is possible to draw conclusions on the filtration system performance and wear generation in the gears. Limitations of the proposed model are the lack of ability to describe noise and random burst spikes attributed to measurement error distributions. Trending of gear wear...

  4. Epileptic Seizure Detection and Prediction Based on Continuous Cerebral Blood Flow Monitoring – a Review

    Directory of Open Access Journals (Sweden)

    Senay Tewolde

    2015-01-01

    Full Text Available Epilepsy is the third most common neurological illness, affecting 1% of the world’s population. Despite advances in medicine, about 25 to 30% of the patients do not respond to or cannot tolerate the severe side effects of medical treatment, and surgery is not an option for the majority of patients with epilepsy. The objective of this article is to review the current state of research on seizure detection based on cerebral blood flow (CBF data acquired by thermal diffusion flowmetry (TDF, and CBF-based seizure prediction. A discussion is provided on the applications, advantages, and disadvantages of TDF in detecting and localizing seizure foci, as well as its role in seizure prediction. Also presented are an overview of the present challenges and possible future research directions (along with methodological guidelines of the CBF-based seizure detection and prediction methods.

  5. Clean water billing monitoring system using flow liquid meter sensor and SMS gateway

    Science.gov (United States)

    Fahmi, F.; Hizriadi, A.; Khairani, F.; Andayani, U.; Siregar, B.

    2018-03-01

    Public clean water company (PDAM) as a public service is designed and organized to meet the needs of the community. Currently, the number of PDAM subscribers is very big and will continue to grow, but the service and facilities to customers are still done conventionally by visiting the customer’s home to record the last position of the meter. One of the problems of PDAM is the lack of disclosure of PDAM customers’ invoice because it is only done monthly. This, of course, makes PDAM customers difficult to remember the date of payment of water account. Therefore it is difficult to maintain the efficiency. The purpose of this research is to facilitate customers of PDAM water users to know the details of water usage and the time of payment of water bills easily. It also facilitates customers in knowing information related to the form of water discharge data used, payment rates, and time grace payments using SMS Gateway. In this study, Flow Liquid Meter Sensor was used for data retrieval of water flowing in the piping system. Sensors used to require the help of Hall Effect sensor that serves to measure the speed of water discharge and placed on the pipe that has the same diameter size with the sensor diameter. The sensor will take the data from the rate of water discharge it passes; this data is the number of turns of the mill on the sensor. The results of the tests show that the built system works well in helping customers know in detail the amount of water usage in a month and the bill to be paid

  6. Migrants in Transit: The Importance of Monitoring HIV Risk Among Migrant Flows at the Mexico–US Border

    Science.gov (United States)

    Martinez-Donate, Ana P.; Hovell, Melbourne F.; Rangel, Maria Gudelia; Zhang, Xiao; Sipan, Carol L.; Magis-Rodriguez, Carlos; Gonzalez-Fagoaga, J. Eduardo

    2015-01-01

    We conducted a probability-based survey of migrant flows traveling across the Mexico–US border, and we estimated HIV infection rates, risk behaviors, and contextual factors for migrants representing 5 distinct migration phases. Our results suggest that the influence of migration is not uniform across genders or risk factors. By considering the predeparture, transit, and interception phases of the migration process, our findings complement previous studies on HIV among Mexican migrants conducted at the destination and return phases. Monitoring HIV risk among this vulnerable transnational population is critical for better understanding patterns of risk at different points of the migration process and for informing the development of protection policies and programs. PMID:25602882

  7. Confocal Microscopy Monitoring of pH Dynamics in a 5-Species Dental Biofilm Model Under Flow Conditions

    DEFF Research Database (Denmark)

    Schlafer, Sebastian; Dige, Irene

    2017-01-01

    -species biofilm model of dental caries under static and flow conditions. Biofilms were grown in the absence of sucrose in ibidi µ-slides for 30 h or 120 h. Biofilms were then stained with the ratiometric probe C-SNARF-4 at pH 7.0, incubated with 0.4% glucose, and z-stacks were acquired in 9 microscopic......Measuring pH dynamics in dental biofilms is of utmost importance for a thorough understanding of the caries process. We have developed a confocal microscopy based methodology to monitor pH in biofilms at the microscale in real-time. Here, we measure pH developments in different layers of a 5...

  8. Flame Retardant Epoxy Resins

    Science.gov (United States)

    Thompson, C. M.; Smith, J. G., Jr.; Connell, J. W.; Hergenrother, P. M.; Lyon, R. E.

    2004-01-01

    As part of a program to develop fire resistant exterior composite structures for future subsonic commercial aircraft, flame retardant epoxy resins are under investigation. Epoxies and their curing agents (aromatic diamines) containing phosphorus were synthesized and used to prepare epoxy formulations. Phosphorus was incorporated within the backbone of the epoxy resin and not used as an additive. The resulting cured epoxies were characterized by thermogravimetric analysis, propane torch test, elemental analysis and microscale combustion calorimetry. Several formulations showed excellent flame retardation with phosphorous contents as low as 1.5% by weight. The fracture toughness of plaques of several cured formulations was determined on single-edge notched bend specimens. The chemistry and properties of these new epoxy formulations are discussed.

  9. High Throughput Strontium Isotope Method for Monitoring Fluid Flow Related to Geological CO2 Storage

    Science.gov (United States)

    Capo, R. C.; Wall, A. J.; Stewart, B. W.; Phan, T. T.; Jain, J. C.; Hakala, J. A.; Guthrie, G. D.

    2012-12-01

    Natural isotope tracers, such as strontium (Sr), can be a unique and powerful component of a monitoring strategy at a CO2 storage site, facilitating both the quantification of reaction progress for fluid-rock interactions and the tracking of brine migration caused by CO2 injection. Several challenges must be overcome, however, to enable the routine use of isotopic tracers, including the ability to rapidly analyze numerous aqueous samples with potentially complex chemical compositions. In a field situation, it might be necessary to analyze tens of samples over a short period of time to identify subsurface reactions and respond to unexpected fluid movement in the host formation. These conditions require streamlined Sr separation chemistry for samples ranging from pristine groundwaters to those containing high total dissolved solids, followed by rapid measurement of isotope ratios with high analytical precision. We have optimized Sr separation chemistry and MC-ICP-MS methods to provide rapid and precise measurements of isotope ratios in geologic, hydrologic, and environmental samples. These improvements will allow an operator to independently prepare samples for Sr isotope analysis off-site using fast, low cost chemical separation procedures and commercially available components. Existing vacuum-assisted Sr separation procedures were modified by using inexpensive disposable parts to eliminate cross contamination. Experimental results indicate that the modified columns provide excellent separation of Sr from chemically complex samples and that Sr can be effectively isolated from problematic matrix elements (e.g., Ca, Ba, K) associated with oilfield brines and formation waters. The separation procedure is designed for high sample throughput in which batches of 24 samples can be processed in approximately 2 hours, and are ready for Sr isotope measurements by MC-ICP-MS immediately after collection from the columns. Precise Sr isotope results can be achieved by MC

  10. Bismaleimide Copolymer Matrix Resins

    Science.gov (United States)

    Parker, John A.; Heimbuch, Alvin H.; Hsu, Ming-Ta S.; Chen, Timothy S.

    1987-01-01

    Graphite composites, prepared from 1:1 copolymer of two new bismaleimides based on N,N'-m-phenylene-bis(m-amino-benzamide) structure have mechanical properties superior to those prepared from other bismaleimide-type resins. New heat-resistant composites replace metal in some structural applications. Monomers used to form copolymers with superior mechanical properties prepared by reaction of MMAB with maleic or citraconic anhydride.

  11. System for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2010-11-23

    A resin recycling system that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The system includes receiving the resin in container form. A grinder grinds the containers into resin particles. The particles are exposed to a solvent in one or more solvent wash vessels, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. A separator is used to separate the resin particles and the solvent. The resin particles are then placed in solvent removing element where they are exposed to a solvent removing agent which removes any residual solvent remaining on the resin particles after separation.

  12. Combining flow cytometry and 16S rRNA gene pyrosequencing: A promising approach for drinking water monitoring and characterization

    KAUST Repository

    Prest, Emmanuelle I E C

    2014-10-01

    The combination of flow cytometry (FCM) and 16S rRNA gene pyrosequencing data was investigated for the purpose of monitoring and characterizing microbial changes in drinking water distribution systems. High frequency sampling (5min intervals for 1h) was performed at the outlet of a treatment plant and at one location in the full-scale distribution network. In total, 52 bulk water samples were analysed with FCM, pyrosequencing and conventional methods (adenosine-triphosphate, ATP; heterotrophic plate count, HPC). FCM and pyrosequencing results individually showed that changes in the microbial community occurred in the water distribution system, which was not detected with conventional monitoring. FCM data showed an increase in the total bacterial cell concentrations (from 345±15×103 to 425±35×103cellsmL-1) and in the percentage of intact bacterial cells (from 39±3.5% to 53±4.4%) during water distribution. This shift was also observed in the FCM fluorescence fingerprints, which are characteristic of each water sample. A similar shift was detected in the microbial community composition as characterized with pyrosequencing, showing that FCM and genetic fingerprints are congruent. FCM and pyrosequencing data were subsequently combined for the calculation of cell concentration changes for each bacterial phylum. The results revealed an increase in cell concentrations of specific bacterial phyla (e.g., Proteobacteria), along with a decrease in other phyla (e.g., Actinobacteria), which could not be concluded from the two methods individually. The combination of FCM and pyrosequencing methods is a promising approach for future drinking water quality monitoring and for advanced studies on drinking water distribution pipeline ecology. © 2014 Elsevier Ltd.

  13. PILOT-SCALE HYDRAULIC TESTING OF RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D

    2007-01-09

    morphology. The skeletal density of the RF resin in the 24-inch IX Column increased slightly with cycling (in both hydrogen and sodium form). The chemical solutions used in the pilot-scale testing remained clear throughout testing, indicating very little chemical breakdown of the RF resin beads. The RF resin particles did not break down and produce fines, which would have resulted in higher pressure drops across the resin bed. Three cesium (Cs) loading tests were conducted on the RF resin in pilot-scale IX columns. Laboratory analyses concluded the Cs in the effluent never exceeded the detection limit. Therefore, there was no measurable degradation in cesium removal performance. Using the pilot-scale systems to add the RF resin to the columns and removing the resin from the columns was found to work well. The resin was added and removed from the columns three times with no operational concerns. Whether the resin was in sodium or hydrogen form, the resin flowed well and resulted in an ideal resin bed formation during each Resin Addition. During Resin Removal, 99+ % of the resin was easily sluiced out of the IX column. The hydraulic performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins, and SRNL testing indicates that the resin should hold up to many cycles in actual radioactive Cs separation. The RF resin was found to be durable in the long term cycle testing and should result in a cost saving in actual operations when compared to other IX resins.

  14. PILOT-SCALE HYDRAULIC TESTING OF RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D

    2006-11-08

    morphology. The skeletal density of the RF resin in the 24 inch IX Column increased slightly with cycling (in both hydrogen and sodium form). The chemical solutions used in the pilot-scale testing remained clear throughout testing, indicating very little chemical breakdown of the RF resin beads. The RF resin particles did not break down and produce fines, which would have resulted in higher pressure drops across the resin bed. Three cesium (Cs) loading tests were conducted on the RF resin in pilot-scale IX columns. Laboratory analyses concluded the Cs in the effluent never exceeded the detection limit. Therefore, there was no measurable degradation in cesium removal performance. Using the pilot-scale systems to add the RF resin to the columns and removing the resin from the columns was found to work well. The resin was added and removed from the columns three times with no operational concerns. Whether the resin was in sodium or hydrogen form, the resin flowed well and resulted in an ideal resin bed formation during each Resin Addition. During Resin Removal, 99+ % of the resin was easily sluiced out of the IX column. The hydraulic performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins, and SRNL testing indicates that the resin should hold up to many cycles in actual radioactive Cs separation. The RF resin was found to be durable in the long term cycle testing and should result in a cost saving in actual operations when compared to other IX resins.

  15. PILOT-SCALE HYDRAULIC TESTING OF RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN

    International Nuclear Information System (INIS)

    Adamson, D

    2007-01-01

    morphology. The skeletal density of the RF resin in the 24-inch IX Column increased slightly with cycling (in both hydrogen and sodium form). The chemical solutions used in the pilot-scale testing remained clear throughout testing, indicating very little chemical breakdown of the RF resin beads. The RF resin particles did not break down and produce fines, which would have resulted in higher pressure drops across the resin bed. Three cesium (Cs) loading tests were conducted on the RF resin in pilot-scale IX columns. Laboratory analyses concluded the Cs in the effluent never exceeded the detection limit. Therefore, there was no measurable degradation in cesium removal performance. Using the pilot-scale systems to add the RF resin to the columns and removing the resin from the columns was found to work well. The resin was added and removed from the columns three times with no operational concerns. Whether the resin was in sodium or hydrogen form, the resin flowed well and resulted in an ideal resin bed formation during each Resin Addition. During Resin Removal, 99+ % of the resin was easily sluiced out of the IX column. The hydraulic performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins, and SRNL testing indicates that the resin should hold up to many cycles in actual radioactive Cs separation. The RF resin was found to be durable in the long term cycle testing and should result in a cost saving in actual operations when compared to other IX resins

  16. Oil production towards biofuel from autotrophic microalgae semicontinuous cultivations monitorized by flow cytometry.

    Science.gov (United States)

    da Silva, Teresa Lopes; Reis, Alberto; Medeiros, Roberto; Oliveira, Ana Cristina; Gouveia, Luisa

    2009-11-01

    Two microalgae species (Scenedesmus obliquus and Neochloris oleoabundans) were cultivated in closed sleeve photobioreactors in order to select the best oil producer for further large-scale open raceway pond cultivations, aiming at biofuel production. Scenedesmus obliquus reached a higher maximum biomass concentration (1.41 g l(-1)) with a lower lipid content (12.8% w/w), as compared to N. oleoabundans [maximum biomass concentration of 0.92 g l(-1) with 16.5% (w/w) lipid content]. Both microalgae showed adequate fatty acid composition and iodine values as substitutes for diesel fuel. Based on these results, N. oleoabundans was selected for further open raceway pond cultivations. Under these conditions, N. oleoabundans reached a maximum biomass concentration of 2.8 g l(-1) with 11% (w/w) of lipid content. A high correlation between the Nile Red fluorescence intensity measured by flow cytometry and total lipid content assayed by the traditional gravimetric lipid analysis was found for both microalgae, making this method a suitable and quick technique for the screening of microalgae strains for lipid production and optimization of biofuel production bioprocesses. Medium growth optimization for enhancement of microalgal oil production is now in progress.

  17. Controlling and Monitoring the Data Flow of the LHCb Read-out and DAQ Network

    CERN Multimedia

    Schwemmer, R; Neufeld, N; Svantesson, D

    2011-01-01

    The LHCb readout uses a set of 320 FPGA based boards as interface between the on-detector hardware and the GBE DAQ network. The boards are the logical Level 1 (L1) read-out electronics and aggregate the experiment's raw data into event fragments that are sent to the DAQ network. To control the many parameters of the read-out boards, an embedded PC is included on each board, connecting to the boards ICs and FPGAs. The data from the L1 boards is sent through an aggregation network into the High Level Trigger farm. The farm comprises approximately 1500 PCs which at first assemble the fragments from the L1 boards and then do a partial reconstruction and selection of the events. In total there are approximately 3500 network connections. Data is pushed through the network and there is no mechanism for resending packets. Loss of data on a small scale is acceptable but care has to be taken to avoid data loss if possible. To monitor and debug losses, different probes are inserted throughout the entire read-out chain t...

  18. Controlling and Monitoring the Data Flow of the LHCb Read-out and DAQ Network

    CERN Document Server

    Schwemmer, Rainer; Neufeld, N; Svantesson, D

    2011-01-01

    The LHCb read-out uses a set of 320 FPGA based boards as interface between the on-detector hardware and the GBE DAQ network. The boards are the logical Level 1 (L1) read-out electronics and aggregate the experiment’s raw data into event fragments that are sent to the DAQ network. To control the many parameters of the read-out boards, an embedded PC is included on each board, connecting to the boards ICs and FPGAs. The data from the L1 boards is sent through an aggregation network into the High Level Trigger farm. The farm comprises approximately 1500 PCs which at first assemble the fragments from the L1 boards and then do a partial reconstruction and selection of the events. In total there are approximately 3500 network connections. Data is pushed through the network and there is no mechanism for resending packets. Loss of data on a small scale is acceptable but care has to be taken to avoid data loss if possible. To monitor and debug losses, different probes are inserted throughout the entire read-out cha...

  19. Controlling and monitoring the data flow of the LHCb read-out and DAQ network

    International Nuclear Information System (INIS)

    Schwemmer, R.; Gaspar, C.; Neufeld, N.; Svantesson, D.

    2012-01-01

    The LHCb read-out uses a set of 320 FPGA based boards as interface between the on-detector hardware and the GBE DAQ network. The boards are the logical Level 1 (L1) read-out electronics and aggregate the experiment's raw data into event fragments that are sent to the DAQ network. To control the many parameters of the read-out boards, an embedded PC is included on each board, connecting to the boards ICs and FPGAs. The data from the L1 boards is sent through an aggregation network into the High Level Trigger farm. The farm comprises approximately 1500 PCs which at first assemble the fragments from the L1 boards and then do a partial reconstruction and selection of the events. In total there are approximately 3500 network connections. Data is pushed through the network and there is no mechanism for resending packets. Loss of data on a small scale is acceptable but care has to be taken to avoid data loss if possible. To monitor and debug losses, different probes are inserted throughout the entire read-out chain to count fragments, packets and their rates at different positions. To keep uniformity throughout the experiment, all control software was developed using the common SCADA software, PVSS, with the JCOP framework as base. The presentation will focus on the low level controls interface developed for the L1 boards and the networking probes, as well as the integration of the high level user interfaces into PVSS. (authors)

  20. Doppler sonography to monitor flow in different cerebral arteries in the rabbit.

    Science.gov (United States)

    Roatta, S; Roncari, S; Micieli, G; Bosone, D; Passatore, M

    2000-07-01

    Most of the transcranial Doppler (TCD) experimental studies on cerebral haemodynamics have been performed in the rabbit because of the similarity between its Willis circle and that of the human, but these studies have mainly been limited to the basilar artery. The present study was aimed at extending the use of TCD sonography to all other large cerebral arteries. In anaesthetised rabbits, these arteries were insonated from three different recording sites, i.e. top-cranial, suboccipital and orbital, using a two-channel pulsed Doppler device equipped with 4 and 8 MHz probes. First, discrimination between intra- and extracranial arteries was achieved through a standard 'rebreathing' test (hypercapnic-hypoxic stimulation). The distinctive blood velocity response patterns, reflecting the different extents of metabolic reactivity in intra- and extracranial territories, are described and discussed. Intracranial arteries were then identified on the basis of their response to ipsi- and contralateral common carotid artery occlusion. This procedure allowed recording from the following arteries: anterior common trunk, anterior cerebral, internal carotid, middle cerebral and basilar; the latter could be simultaneously monitored with any of the others. This study provides an experimental model allowing investigation of regional differences in the haemodynamic response to neurogenic and pharmacological stimuli.

  1. Effects of colloidal nanosilica on the rheological properties of epoxy resins filled with organoclay.

    Science.gov (United States)

    Nguyen, Dinh Huong; Song, Gwang Seok; Lee, Dai Soo

    2011-05-01

    The rheological properties of epoxy resins filled with organoclay and colloidal nanosilica were investigated by employing a parallel plate rheometer in flow mode at 25 degrees C. Shear thickening and shear thinning behaviors were observed in the epoxy resins filled with a mixture of organoclay and colloidal nanosilica. Minima were observed in the relaxation time of the systems consisting of epoxy resins filled with organoclay and colloidal silica as the content of colloidal nanosilica was increased. It seems that the colloidal nanosilica increased the mobility of the filled epoxy resins and reduced the interactions between the silicate layers in the systems.

  2. Paramagnetic epoxy resin

    Directory of Open Access Journals (Sweden)

    E. C. Vazquez Barreiro

    2017-01-01

    Full Text Available This work illustrates that macrocycles can be used as crosslinking agents for curing epoxy resins, provided that they have appropriate organic functionalities. As macrocycles can complex metal ions in their structure, this curing reaction allows for the introduction of that metal ion into the resin network. As a result, some characteristic physical properties of the metallomacrocycle could be transferred to the new material. The bisphenol A diglycidyl ether (BADGE, n = 0 and hemin (a protoporphyrin IX containing the Fe(III ion, and an additional chloride ligand have been chosen. The new material has been characterized by differential scanning calorimetry (DSC, thermogravimetric analysis (TGA, Fourier Transform Infrared (FT-IR, Nuclear Magnetic Resonance (NMR, Transmission Electron Microscopy (TEM, and magnetic susceptibility measurements. Fe(III remains in the high-spin state during the curing process and, consequently, the final material exhibits the magnetic characteristics of hemin. The loss of the chlorine atom ligand during the cure of the resin allows that Fe(III can act as Lewis acid, catalyzing the crosslinking reactions. At high BADGE n = 0/hemin ratios, the formation of ether and ester bonds occurs simultaneously during the process.

  3. Batch and Continuous Flow Preparation of Hantzsch 1,4-Dihydropyridines under Microwave Heating and Simultaneous Real-time Monitoring by Raman Spectroscopy. An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Sylvain Christiaens

    2014-07-01

    Full Text Available Dialkyl 1,4-dihydro-2,6-dimethylpyridine-3,5-dicarboxylates have been prepared in a batch mode under conventional heating as well as under continuous flow conditions in the Miniflow 200SS, Sairem’s microwave-assisted batch and continuous flow equipment. Real-time monitoring of the reactions by Raman spectroscopy enabled to compare both heating modes and to determine (optimized reaction times.

  4. Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method

    KAUST Repository

    Prest, Emmanuelle I E C

    2013-12-01

    Flow cytometry (FCM) is a rapid, cultivation-independent tool to assess and evaluate bacteriological quality and biological stability of water. Here we demonstrate that a stringent, reproducible staining protocol combined with fixed FCM operational and gating settings is essential for reliable quantification of bacteria and detection of changes in aquatic bacterial communities. Triplicate measurements of diverse water samples with this protocol typically showed relative standard deviation values and 95% confidence interval values below 2.5% on all the main FCM parameters. We propose a straightforward and instrument-independent method for the characterization of water samples based on the combination of bacterial cell concentration and fluorescence distribution. Analysis of the fluorescence distribution (or so-called fluorescence fingerprint) was accomplished firstly through a direct comparison of the raw FCM data and subsequently simplified by quantifying the percentage of large and brightly fluorescent high nucleic acid (HNA) content bacteria in each sample. Our approach enables fast differentiation of dissimilar bacterial communities (less than 15min from sampling to final result), and allows accurate detection of even small changes in aquatic environments (detection above 3% change). Demonstrative studies on (a) indigenous bacterial growth in water, (b) contamination of drinking water with wastewater, (c) household drinking water stagnation and (d) mixing of two drinking water types, univocally showed that this FCM approach enables detection and quantification of relevant bacterial water quality changes with high sensitivity. This approach has the potential to be used as a new tool for application in the drinking water field, e.g. for rapid screening of the microbial water quality and stability during water treatment and distribution in networks and premise plumbing. © 2013 Elsevier Ltd.

  5. Long term monitoring of water production flow rates in boreholes in the Callovo-Oxfordian argillaceous rock

    International Nuclear Information System (INIS)

    Vinsot, A.; Delay, J.; La Vaissiere, R. de; Cruchaudet, M.

    2010-01-01

    Document available in extended abstract form only. Water production was observed in several boreholes in the Callovo-Oxfordian argillaceous rock (COx). These boreholes were implemented in 2005 in the Andra's Underground Research Laboratory (URL) at more than 400 m in depth. Despite the low COx permeability: close to 10-13 m/s, two original experimental setups made it possible to monitor water production flow rates ranging from 0.5 to 50 mL/day during 3 to 4 years in 4 boreholes. This contribution describes the water flow rate evaluation methods and the results obtained from several experimental phases which may be considered as a series of constant pressure production tests. The first experimental concept was based on seepage water collection. It consisted in filling with gas the interval of an ascending borehole at a pressure close to 1 bar and closing it. The hydraulic pressure in the rock surrounding the sealed interval was higher than 30 bars. Due to the hydraulic pressure difference between the interval and the surrounding rock, the interstitial water of the formation flowed into the interval, accumulated at its base by gravity and was pumped out at a controlled flow rate. The pumping rate was adjusted so that the water level would not exceed 40 cm inside the 5-meter-long interval. The water level was deduced from the difference between two absolute pressure measurements: one above the water surface in the gas phase and the other at the bottom of the water column. The total volume of the daily produced formation water was obtained by adding the water volume pumped out during the day and the water volume difference inside the interval between the beginning and the end of the day. This kind of experiment was performed in two boreholes. The second experimental concept was based on water circulation. It consisted in filling with water the interval of a descending borehole. Two water circulation lines and one pressure control line linked the test interval to

  6. Biokompatibilitas Gelas Ionomer Modifikasi Resin

    OpenAIRE

    Rotua Lestari M

    2008-01-01

    Saat ini banyak berkembang material baru dalam dunia kedokteran gigi diantaranya adalah Gelas ionomer modifikasi resin yang dikembangkan untuk mengatasi kekurangan-kekurangan dari gelas ionomer konvensional. Adanya penambahan monomer resin daIam bentuk 2-hydroxyethylmetacylate (HEMA) telah meningkatkan kekuatan dari bahan ini. Gelas ionomer modifikasi resin mempunyai sifat-sifat fisis dan mekanis yang lebih baik dibandingkan dengan gelas ionomer konvensional. Gelas ionomer modifikasi ...

  7. Interacting Blends of Novel Unsaturated Polyester Amide Resin with Vinyl Acetate

    Directory of Open Access Journals (Sweden)

    H. S. Patel

    2004-01-01

    Full Text Available Novel unsaturated poly (ester- amide resins (UPEAs were prepared by the reaction between an epoxy resin, namely diglycidyl ether of bisphenol–A (DGEBA and unsaturated aliphatic bisamic acids using a base catalyst. These UPEAs were then blended with a vinyl monomer namely, Vinyl acetate (VA to produce a homogeneous resin syrup. The curing of these UPEAs-VA resin blends was carried out by using benzoyl peroxide (BPO as an initiator for the radical polymerization and was monitored by using a differential scanning calorimeter (DSC. The glass fibre reinforced composites (i.e. laminates of these UPEA-VA resin blends were fabricated using the DSC data. The chemical, mechanical and electrical properties of the glass fibre composites have also been evaluated. The unreinforced cured samples of the UPEA-VA resin blends were also analyzed by thermogravimetry (TGA.

  8. Effects of Prepolymerized Particle Size and Polymerization Kinetics on Volumetric Shrinkage of Dental Modeling Resins

    Directory of Open Access Journals (Sweden)

    Tae-Yub Kwon

    2014-01-01

    Full Text Available Dental modeling resins have been developed for use in areas where highly precise resin structures are needed. The manufacturers claim that these polymethyl methacrylate/methyl methacrylate (PMMA/MMA resins show little or no shrinkage after polymerization. This study examined the polymerization shrinkage of five dental modeling resins as well as one temporary PMMA/MMA resin (control. The morphology and the particle size of the prepolymerized PMMA powders were investigated by scanning electron microscopy and laser diffraction particle size analysis, respectively. Linear polymerization shrinkage strains of the resins were monitored for 20 minutes using a custom-made linometer, and the final values (at 20 minutes were converted into volumetric shrinkages. The final volumetric shrinkage values for the modeling resins were statistically similar (P>0.05 or significantly larger (P<0.05 than that of the control resin and were related to the polymerization kinetics (P<0.05 rather than the PMMA bead size (P=0.335. Therefore, the optimal control of the polymerization kinetics seems to be more important for producing high-precision resin structures rather than the use of dental modeling resins.

  9. HIGH ASPECT RATIO ION EXCHANGE RESIN BED - HYDRAULIC RESULTS FOR SPERICAL RESIN BEADS

    International Nuclear Information System (INIS)

    Duignan, M; Charles Nash, C; Timothy Punch, T

    2007-01-01

    A principal role of the DOE Savannah River Site is to safely dispose of a large volume of liquid nuclear waste held in many storage tanks. An in-tank ion exchange unit is being considered for cesium removal to accelerate waste processing. This unit is planned to have a relatively high bed height to diameter ratio (10:1). Complicating the design is the need to cool the ion exchange media; therefore, the ion exchange column will have a central cooling core making the flow path annular. To separate cesium from waste the media being considered is made of resorcinol formaldehyde resin deposited on spherical plastic beads and is a substitute for a previously tested resin made of crystalline silicotitanate. This spherical media not only has an advantage of being mechanically robust, but, unlike its predecessor, it is also reusable, that is, loaded cesium can be removed through elution and regeneration. Resin regeneration leads to more efficient operation and less spent resin waste, but its hydraulic performance in the planned ion exchange column was unknown. Moreover, the recycling process of this spherical resorcinol formaldehyde causes its volume to significantly shrink and swell. To determine the spherical media's hydraulic demand a linearly scaled column was designed and tested. The waste simulant used was prototypic of the wastes' viscosity and density. This paper discusses the hydraulic performance of the media that will be used to assist in the design of a full-scale unit

  10. Technology’s present situation and the development prospects of energy efficiency monitoring as well as performance testing & analysis for process flow compressors

    Science.gov (United States)

    Li, L.; Zhao, Y.; Wang, L.; Yang, Q.; Liu, G.; Tang, B.; Xiao, J.

    2017-08-01

    In this paper, the background of performance testing of in-service process flow compressors set in user field are introduced, the main technique barriers faced in the field test are summarized, and the factors that result in real efficiencies of most process flow compressors being lower than the guaranteed by manufacturer are analysed. The authors investigated the present operational situation of process flow compressors in China and found that low efficiency operation of flow compressors is because the compressed gas is generally forced to flow back into the inlet pipe for adapting to the process parameters variety. For example, the anti-surge valve is always opened for centrifugal compressor. To improve the operation efficiency of process compressors the energy efficiency monitoring technology was overviewed and some suggestions are proposed in the paper, which is the basis of research on energy efficiency evaluation and/or labelling of process compressors.

  11. Fissure sealant materials: Wear resistance of flowable composite resins.

    Science.gov (United States)

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  12. Fissure sealant materials: Wear resistance of flowable composite resins

    Directory of Open Access Journals (Sweden)

    Sohrab Asefi

    2016-08-01

    Full Text Available Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow, Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists. A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  13. Composite fabrication via resin transfer molding technology

    Energy Technology Data Exchange (ETDEWEB)

    Jamison, G.M.; Domeier, L.A.

    1996-04-01

    The IMPReS (Integrated Modeling and Processing of Resin-based Structures) Program was funded in FY95 to consolidate, evaluate and enhance Sandia`s capabilities in the design and fabrication of composite structures. A key driver of this and related programs was the need for more agile product development processes and for model based design and fabrication tools across all of Sandia`s material technologies. A team of polymer, composite and modeling personnel was assembled to benchmark Sandia`s existing expertise in this area relative to industrial and academic programs and to initiate the tasks required to meet Sandia`s future needs. RTM (Resin Transfer Molding) was selected as the focus composite fabrication technology due to its versatility and growing use in industry. Modeling efforts focused on the prediction of composite mechanical properties and failure/damage mechanisms and also on the uncured resin flow processes typical of RTM. Appropriate molds and test composites were fabricated and model validation studies begun. This report summarizes and archives the modeling and fabrication studies carried out under IMPReS and evaluates the status of composite technology within Sandia. It should provide a complete and convenient baseline for future composite technology efforts within Sandia.

  14. Development of a low-cost wireless controller for flexible sampling strategies based on real-time flow monitoring

    Science.gov (United States)

    Queloz, Pierre; Besuchet, Jonathan; Rao, P. Suresh C.; Rinaldo, Andrea

    2013-04-01

    Even if models are able to predict more and more accurately pollutant discharge in streams, surface water sampling remains a very common practice to monitor substance concentrations and loads in streams and to calibrate models. However, as this method is temporally and spatially punctual, monitoring a whole catchment requires multiple sampling sites with time-distributed samples. Instruments are expensive, and sample collection, on-site interventions and maintenance are costly and time-consuming, in particular if the experimental site is remote. Another issue is the estimation of the discharge loads of a pollutant, especially for non-chemostatic compounds; their hydrograph-related chemical dynamics may be miss-evaluated when a rapid storm occurs using a time-paced sampling strategy with large sampling intervals. Many manufacturers provide discharge gauges (pressure probes or ultra-sonic sensors) or other instruments (rain gauge, chemical probes, etc.) that can be coupled with automatic water samplers in order to program an event-paced sampling. However, automatic samplers usually provide limited programming options that may not meet the needs of the experimenter of a specific catchment. The concept presented here proposes to use a simple microcontroller board in order to determine the timing of the samples by sending electrical pulses to a conventional automatic sampler with input capability. The flow level is measured by a low-cost ultrasonic sensor and sent to the microcontroller, which will process the signal according to user and site-custom parameters. For example, a simple power-law recession model can be apply to approximate the duration of the recession period given the maximal discharge rate measured for a storm. The sample intervals can thereafter be set in order to distribute all the bottles available over the total recession duration. The microcontroller sends a pulse (grab sample query) to the sampler at every sample time calculated by the program. A

  15. Features of 24-hour monitoring of blood pressure, serum urotensin II and angiotensin II levels, vascular remodeling and extracranial blood flow in patients with hypertension

    Directory of Open Access Journals (Sweden)

    V. A. Vizir

    2015-12-01

    Full Text Available Hypertension is the main cause of morbidity, disability and mortality in the adult population in most countries of the world. Aim. Aiming to establish the features of 24-hour monitoring of blood pressure, serum urotensin II and angiotensin II concentrations, vascular remodeling and extracranial blood flow in patients with stage II hypertension associated with carotid atherosclerosis, cerebral blood flow indexes were studied in 102 patients using duplex scanning of extracranial arteries, 24-hour blood pressure monitoring. Serum urotensin II and angiotensin II levels were determined with immunoenzymatic method. Results. It was found that the average 24-hour, average daytime values of systolic and diastolic blood pressure, variability indicators and blood pressure load were significantly higher in the patients of the first group of observation. Among cerebral blood flow indexes, statistically significant differences were showed by linear blood flow velocity, intima-media thickness, RI and PI. The patients with stage II hypertension associated with extracranial arterial lesions had probably higher serum urotensin II concentrations. Conclusion. This indicates higher levels of 24-hour blood pressure monitoring indexes, severe disorders of cerebral blood flow and neurohormonal activation in case of simultaneous hypertension and atherosclerotic lesion of brachiocephalic arteries.

  16. Characterisation of Rapeseed Oil Based Resins Using Infrared and ...

    African Journals Online (AJOL)

    The hydroxylated chemical structure was crosslinked using methylene-pphenyl diisocyanate to produce a thermoset rapeseed oil resin. The cross linking process was monitored in situ using the Attenuated Total Internal Reflectance Fourier Transform-Infrared spectroscopy and the thermogravimetric analysis techniques.

  17. Properties of the Carboxylate ion exchange resins

    International Nuclear Information System (INIS)

    Allard, Bert; Dario, Maarten; Boren, Hans; Torstenfelt, Boerje; Puigdomenech, Ignasi; Johansson, Claes

    2002-09-01

    Weakly acidic, carboxylic resin has been selected, together with strong base anion resins, for water purification at the Forsmark 1 and 2 reactors. For the strong (but not the weak) ion exchange resin the Nuclear Power Inspectorate has given permission to dispose the spent resins in the SFR 1 (the Final Repository for Radioactive Operational Waste). This report gives a review of the carboxylic resins and comes to the conclusion that the resins are very stable and that there should not exist any risks for increased leaching of radionuclides from SFR 1 if these resins are disposed (compared to the strong resins)

  18. Development of a reliability monitor for the safety related subsystem of a PWR considering the redundancy and maintenance of components by fault tree and GO-FLOW methodologies

    International Nuclear Information System (INIS)

    Hashim Muhammad; Matsuoka, Takeshi; Yang Ming

    2012-01-01

    A reliability monitor checks the operating performance of each of the individual subsystems that comprise the whole system and display the reliability of the subsystems. By monitoring the reliability of individual subsystems, the operators of the plant can gain insight on potential performance bottlenecks to establish baseline performance. Monitoring the reliability of the subsystems also helps the plant operator to find problems before real loss of service occurs. The GO-FLOW method is based on success-oriented system analysis technique. This technique is able to evaluate the system reliability and availability. An example analysis is conducted by GO-FLOW to obtain the dynamic reliability curve of the containment spray system in a PWR. It is shown by parametric analysis that the system reliability is increased by the redundant system configuration of the containment spray system. (author)

  19. An Engineering Evaluation of Spherical Resorcinol Formaldehyde Resin

    Energy Technology Data Exchange (ETDEWEB)

    Birdwell Jr, Joseph F [ORNL; Lee, Denise L [ORNL; Taylor, Paul Allen [ORNL; Collins, Robert T [ORNL; Hunt, Rodney Dale [ORNL

    2010-09-01

    A small column ion exchange (SCIX) system has been proposed for removal of cesium from caustic, supernatant, and dissolved salt solutions stored or generated from high-level tank wastes at the US Department of Energy (DOE) Hanford Site and Savannah River Sites. In both instances, deployment of SCIX systems, either in-tank or near-tank, is a means of expediting waste pretreatment and dispositioning with minimal or no new infrastructure requirements. Conceptually, the treatment approach can utilize a range of ion exchange media. Previously, both crystalline silicotitanate (CST), an inorganic, nonelutable sorbent, and resorcinol-formaldehyde (RF), an organic, elutable resin, have been considered for cesium removal from tank waste. More recently, Pacific Northwest National Laboratory (PNNL) evaluated use of SuperLig{reg_sign} 644, an elutable ion exchange medium, for the subject application. Results of testing indicate hydraulic limitations of the SuperLig{reg_sign} resin, specifically a high pressure drop through packed ion exchange columns. This limitation is likely the result of swelling and shrinkage of the irregularly shaped (granular) resin during repeated conversions between sodium and hydrogen forms as the resin is first loaded then eluted. It is anticipated that a similar flow limitation would exist in columns packed with conventional, granular RF resin. However, use of spherical RF resin is a likely means of mitigating processing limitations due to excessive pressure drop. Although size changes occur as the spherical resin is cycled through loading and elution operations, the geometry of the resin is expected to effectively mitigate the close packing that leads to high pressure drops across ion exchange columns. Multiple evaluations have been performed to determine the feasibility of using spherical RF resin and to obtain data necessary for design of an SCIX process. The work performed consisted of examination of radiation effects on resin performance

  20. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  1. Cure shrinkage in casting resins

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J. Brock [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    A method is described whereby the shrinkage of a casting resin can be determined. Values for the shrinkage of several resin systems in frequent use by Sandia have been measured. A discussion of possible methods for determining the stresses generated by cure shrinkage and thermal contraction is also included.

  2. Oxidative Neutralization of Mustard-Gas Simulants in an On-Board Flow Device with In-Line NMR Monitoring.

    Science.gov (United States)

    Picard, Baptiste; Gouilleux, Boris; Lebleu, Thomas; Maddaluno, Jacques; Chataigner, Isabelle; Penhoat, Maël; Felpin, François-Xavier; Giraudeau, Patrick; Legros, Julien

    2017-06-19

    The fast and effective neutralization of the mustard-gas simulant 2-chloroethyl ethyl sulfide (CEES) using a simple and portable continuous flow device is reported. Neutralization takes place through a fully selective sulfoxidation by a stable source of hydrogen peroxide (alcoholic solution of urea-H 2 O 2 adduct/MeSO 3 H freshly prepared). The reaction progress can be monitored with an in-line benchtop NMR spectrometer, allowing a real-time adjustment of reaction conditions. Inherent features of millireactors, that is, perfect control of mixing, heat and reaction time, allowed the neutralization of 25 g of pure CEES within 46 minutes in a 21.5 mL millireactor (t R =3.9 minutes). This device, which relies on affordable and nontoxic reagents, fits into a suitcase, and can be deployed by police/military forces directly on the attack site. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Monitoring of regional cerebral blood flow by single photon emission tomography of I123-N-isopropyl-iodoamphetamine in epileptics

    International Nuclear Information System (INIS)

    Magistretti, P.L.; Uren, R.F.; Parker, J.A.; Royal, H.D.; Front, D.; Kolodny, G.M.

    1983-01-01

    In some patients with epileptic disorders it is difficult to accurately localize the seizure focus especially in the case of deep lesions. In an attempt to provide better localization of such foci we have used single photon emission tomography (SPECT) of a new radiopharmaceutical I 123 -N-isopropyl-iodoamphetamine (IMP) to measure regional cerebral blood flow (RCBF) in the ictal and interictal phases. Eight patients were studied. The location of the seizure focus was determined by intraoperative corticography operative findings and pathology in 5 patients and by neuropsychological testing and long-term EEG monitoring in the other three. The SPECT scan accurately localized the seizure focus in all patients. This modality also allowed the functional state of the seizure focus to be assessed. In five of the thirteen studies there was increased RCBF at the seizure focus. On four of these occasions the patients reported symptoms typical of their seizures. In the asymptomatic patient the focally increased RCBF corresponded with a very active superficial epileptic focus on EEG. These preliminary results suggest that SPECT scans of RCBF, will have considerable utility in the management of epileptics. This is particularly the case as the necessary instrumentation is already available in many hospitals, thus minimizing the cost of widespread application

  4. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  5. Interfacial microscopic examination and chemical analysis of resin-dentin interface of self-adhering flowable resin composite [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Tamer M. Hamdy

    2017-10-01

    Full Text Available Background: The newly introduced self-adhering flowable resin-composites decrease the required time for application by incorporation of an acidic adhesive monomer, thus reducing the number of the steps, but its bonding is still uncertain. The aim of this study was to evaluate the interfacial microscopic examination and chemical analysis at the resin-dentin interface of a self-adhering flowable resin composite (Vertise-Flow versus a total-etch (Te-Econom Plus resin composite, using an etching agent (Eco-Etch gel and  bonding agent (Single Bond Universal. Methods: Sixteen freshly extracted sound human posterior teeth were used. The teeth were randomly divided into two groups: 8 specimens per type of composite. Standard-shaped class V cavities were prepared on the buccal surface. One group was restored by Te-Econom Plus resin composite by total-etch technique using Eco-Etch gel, which was applied to dentine for 15 seconds, followed by rinsing, drying and bonding agent application (Single Bond Universal. The other group restored directly with self-adhering resin composite (Vertise-Flow without application of etch or bond. Curing was done for 20 seconds using a light emitting diode light curing unit. Evaluation of the resin-dentin interface was done microscopically by examination of marginal gap distance in μm using scanning electron microscope (SEM, and chemical analysis of silver particles was observed using SEM with energy-dispersive X-ray spectrometry after 24 hours of specimen storage in ammoniacal silver nitrate. Results: Regarding marginal gap distance (µm and silver atomic % mean values, teeth restored with self-adhering resin composite (Vertise-Flow showed significantly higher mean values than the multi-step etch and rinse resin composite group (5.2 vs 0; 12.2 vs 8.2, respectively. Conclusions: Resin-dentin bonding using total-etch resin composite technique was more effective than self-adhering flowable resin composite (Vertise-Flow

  6. Interfacial microscopic examination and chemical analysis of resin-dentin interface of self-adhering flowable resin composite [version 3; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Tamer M. Hamdy

    2017-10-01

    Full Text Available Background: The newly introduced self-adhering flowable resin-composites decrease the required time for application by incorporation of an acidic adhesive monomer, thus reducing the number of steps, but its bonding is still uncertain. The aim of this study was to evaluate the interfacial microscopic examination and chemical analysis at the resin-dentin interface of a self-adhering flowable resin composite (Vertise™Flow Self-Adhering Flowable Composite, Kerr Dental, USA versus a total-etch (Te-Econom Plus resin composite, using an etching agent (Eco-Etch gel and bonding agent (Single Bond Universal. Methods: Sixteen freshly extracted sound human posterior teeth were used. The teeth were randomly divided into two groups: 8 specimens per type of composite. Standard-shaped class V cavities were prepared on the buccal surface. One group was restored by Te-Econom Plus resin composite by total-etch technique using Eco-Etch gel, which was applied to dentine for 15 seconds, followed by rinsing, drying and bonding agent application (Single Bond Universal. The other group restored directly with self-adhering resin composite (Vertise-Flow without application of etch or bond. Curing was done for 20 seconds using a light emitting diode light curing unit. Evaluation of the resin-dentin interface was done microscopically by examination of marginal gap distance in μm using scanning electron microscope (SEM, and chemical analysis of silver particles was observed using SEM with energy-dispersive X-ray spectrometry after 24 hours of specimen storage in ammoniacal silver nitrate. Results: Regarding marginal gap distance (µm and silver atomic % mean values, teeth restored with self-adhering resin composite (Vertise-Flow showed significantly higher mean values than the multi-step etch and rinse resin composite group (5.2 vs 0; 12.2 vs 8.2, respectively. Conclusions: Resin-dentin bonding using total-etch resin composite technique was more effective than self

  7. DEVELOPMENT OF MOLECULAR MONITORING TECHNOLOGIES TO MEASURE TRANSGENE FLOW AND INTROGRESSION IN CROP AND NON-CROP PLANT SPECIES

    Science.gov (United States)

    The Gene Flow Project at the US Environmental Protection Agency, Western Ecology Division is developing methodologies for ecological risk assessments of transgene flow using Agrostis and Brassica engineered with CP4 EPSPS genes that confer resistance to glyphosate herbicide. In ...

  8. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  9. 21 CFR 872.3140 - Resin applicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin applicator. 872.3140 Section 872.3140 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3140 Resin applicator. (a) Identification. A resin applicator is a brushlike device intended for use in spreading dental resin on a tooth during application of...

  10. Static and dynamic flow analysis of PBDEs in plastics from used and end-of-life TVs and computer monitors by life cycle in Korea.

    Science.gov (United States)

    Lee, Seunghun; Jang, Yong-Chul; Kim, Jong-Guk; Park, Jong-Eun; Kang, Young-Yeul; Kim, Woo-Il; Shin, Sun-Kyoung

    2015-02-15

    This study focused on a quantitative substance flow analysis (SFA) of polybrominated diphenyl ethers (PBDEs) in plastics from obsolete TVs and computer monitors that often contain large amounts of the flame retardants. According to the results of the static SFA study, 1.87 tons and 0.28 tons of PBDEs from newly manufactured TVs and computer monitors were introduced into households in 2011 in Korea, respectively. There were approximately 924 tons and 90.3 tons of PBDEs present in TVs and computer monitors in households during product use, respectively. The results of the dynamic SFA study indicated that in 2017 the amount of PBDEs from TVs and computer monitors in the recycling stage is expected to be 2.63 tons and 0.1 tons, respectively. Large fractions of PBDEs from used TVs are present in recycled plastics, while PBDE-containing computer monitors are exported to Southeast Asian countries. This research indicates that PBDEs were emitted the most from recycled plastic pellet processes upon recycling. Further study may be warranted to focus the flow of PBDEs in recycled plastic products in order to determine the final destination and disposal of these chemicals in the environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Physical and chemical durability of cement impregnated epoxy resin

    International Nuclear Information System (INIS)

    Suryantoro

    1997-01-01

    Immobilization of simulation radioactive waste contains Cs and Sr with cement impregnated epoxy resin has been done. Low level liquid waste in 30% weight mixed cement homogeneously and then set in its curing time about 28 days. Waste from was impregnated with epoxy resin (Bisphenol-A-diglycidylether) and use Triethylenteramin as catalyst. the sample of cement impregnated epoxy resin 2.5 cm x 2.5 cm in diameter and length was tested by Paul Weber. The compressive strength was obtained of 4.08 kN.cm - 2. The sochxlet apparatus was run on flow rate of 300 ml/hour at 100 o C and during 24 hours. The leaching rate of Cs was round on 5.5 x 10 - 4 g.cm - 2.d - 1 and Sr was 6.1 x 10 - 4 g.cm - 2.d - 1 (author)

  12. Application and evaluation of LS-PIV technique for the monitoring of river surface velocities in high flow conditions

    OpenAIRE

    Jodeau , M.; Hauet , A.; Paquier , A.; Le Coz , J.; Dramais , G.

    2008-01-01

    Large Scale Particle Image Velocimetry (LS-PIV) is used to measure the surface flow velocities in a mountain stream during high flow conditions due to a reservoir release. A complete installation including video acquisition from a mobile elevated viewpoint and artificial flow seeding has been developed and implemented. The LS-PIV method was adapted in order to take into account the specific constraints of these high flow conditions. Using a usual LS-PIV data processing, significant variations...

  13. Tools for diagnosis, monitoring and screening of Schistosoma infections utilizing lateral-flow based assays and upconverting phosphor labels

    Science.gov (United States)

    CORSTJENS, PAUL L. A. M.; DE DOOD, CLAUDIA J.; KORNELIS, DIEUWKE; FAT, ELISA M. TJON KON; WILSON, R. ALAN; KARIUKI, THOMAS M.; NYAKUNDI, RUTH K.; LOVERDE, PHILIP T.; ABRAMS, WILLIAM R.; TANKE, HANS J.; VAN LIESHOUT, LISETTE; DEELDER, ANDRÉ M.; VAN DAM, GOVERT J.

    2014-01-01

    SUMMARY The potential of various quantitative lateral flow (LF) based assays utilizing up-converting phosphor (UCP) reporters for the diagnosis of schistosomiasis is reviewed including recent developments. Active infections are demonstrated by screening for the presence of regurgitated worm antigens (genus specific polysaccharides), whereas anti-Schistosoma antibodies may indicate ongoing as well as past infections. The circulating anodic antigen (CAA) in serum or urine (and potentially also saliva) is identified as the marker that may allow detection of single-worm infections. Quantitation of antigen levels is a reliable method to study effects of drug administration, worm burden and anti-fecundity mechanisms. Moreover, the ratio of CAA and circulating cathodic antigen (CCA) is postulated to facilitate identification of either Schistosoma mansoni or Schistosoma haematobium infections. The UCP-LF assays allow simultaneous detection of multiple targets on a single strip, a valuable feature for antibody detection assays. Although antibody detection in endemic regions is not a useful tool to diagnose active infections, it gains potential when the ratio of different classes of antibody specific for the parasite/disease can be determined. The UCP-LF antibody assay format allows this type of multiplexing, including testing a linear array of up to 20 different targets. Multiple test spots would allow detection of specific antibodies, e.g. against different Schistosoma species or other pathogens as soil-transmitted helminths. Concluding, the different UCP-LF based assays for diagnosis of schistosomiasis provide a collection of tests with relatively low complexity and high sensitivity, covering the full range of diagnostics needed in control programmes for mapping, screening and monitoring. PMID:24932595

  14. Flow cytometry of nucleated red blood cells used as monitoring technique for aquatic risk assessment. A review.

    Directory of Open Access Journals (Sweden)

    Bratosin D.

    2016-05-01

    Full Text Available During the last decades anthropogenic factors led to a significant enhancement of pollutants in aquatic environment and for several years, chemicals analysis has been commonly employed. These techniques cannot detect and quantify many environmental phenomena such as bioavailability, bioaccumulation and synergistic effects. For these reasons, many investigations for evaluating the effects of xenobiotic on organisms use in vitro or in vivo bioassays. The bioassays give a global response for all chemicals present in the environment and these represent one of the best ways to estimate the risk assessment of pollutants in environment for monitoring. For assessing cytotoxicity or ecotoxicity of pollutants (heavy metals, nanoparticles, etc. and to assess aquatic pollution degree and biomonitoring of Danube River and Danube Delta, we developed a new experimental cell system based on the apoptosis of nucleated erythrocytes from fishes and batrachians which are directly exposed to pollutants absorbed by different ways. Despite their structural simplicity, the erythrocytes of lower vertebrates preserve nucleus and mitochondria, both the sensors of the programmed cell death (PCD machinery to develop an apoptosis phenomenon. Our proposed bioassays which are based on the apoptosis phenomenon as induced biomarker by pollutants on fish or amphibians erythrocytes, evidenced by flow cytometry (apoptosis/necrosis discriminated by FITC-annexin-V labeling/PI and cellular viability measured with calcein-AM method could be rapid and very sensitive tests for in laboratory aquatic risk assessment and biomonitoring. Standardization and application of these tests will surely provide the opportunity of their use easily in ecotoxicological laboratories, biomonitoring of large river basins such as the Danube River Basin and will be also able deliver information on fish as a food product.

  15. 133Xe blood flow monitoring during arteriovenous malformation resection: a case of intraoperative hyperperfusion with subsequent brain swelling

    International Nuclear Information System (INIS)

    Young, W.L.; Solomon, R.A.; Prohovnik, I.; Ornstein, E.; Weinstein, J.; Stein, B.M.

    1988-01-01

    Measurement of regional cerebral blood flow (rCBF) using the i.v. 133Xe technique was carried out during resection of a right temporooccipital arteriovenous malformation (AVM) with ipsilateral middle and posterior cerebral arterial supply. Intraoperatively, a rCBF detector was in place over the right frontotemporal area, about 5 to 6 cm from the border of the AVM. Anesthesia was 0.75% isoflurane in oxygen and nitrous oxide. After dural exposure, the rCBF was 27 ml/100 g/min at a pCO2 of 29 mm Hg and a mean arterial pressure (MAP) of 90 mm Hg. The pCO2 was then elevated to 40 mm Hg, and the rCBF was increased to 55 ml/100 g/min at a MAP of 83 mm Hg. After AVM removal, the rCBF rose to 50 ml/100 g/min at a pCO2 of 27 mm Hg and a MAP of 75 mm Hg. The pCO2 was elevated to 33 mm Hg and the rCBF increased to 86 ml/100 g/min at a MAP of 97 mm Hg. During skin closure, the rCBF was 94 ml/100 g/min at a pCO2 of 26 mm Hg and a MAP of 97 mm Hg. The patient was neurologically normal postoperatively except for a mild, new visual field defect. After 2 to 3 days, the patient gradually developed lethargy, confusion, and nausea with relatively normal blood pressure. An angiogram revealed residual enlargement of the posterior cerebral artery feeding vessel. Computed tomography showed edema extending from the area of AVM resection as far as the frontal region, producing a significant midline shift anteriorly. Intraoperative rCBF monitoring revealed significant hyperperfusion after AVM resection, which was associated with signs and symptoms of the normal perfusion pressure breakthrough syndrome

  16. Glass Reinforcement of Various Epoxy Resins-Polyurea Systems

    Science.gov (United States)

    Joshi, Medha; Jauhari, Smita

    2012-07-01

    Polyureas (PUs) were prepared by the polycondensation reaction of disperse dyes containing -NH2 group and toluene 2, 4-diisocyanate. The disperse dyes have been prepared by coupling of various 2-diazobenzothiazoles with 1,3-benzenediamine. All the PUs were characterized by elemental analysis, spectral studies, number average molecular weight ( {overline{{Mn}} } ), and thermogravimetry. Further reaction of PUs was carried out with an epoxy resin (i.e., DGEBA). The curing study of prepared resins was monitored by differential scanning calorimeter (DSC). Based on DSC, thermograms glass fiber-reinforced composites have been laminated and characterized by chemical, mechanical, and electrical properties. The unreinforced cured resins were subjected to thermogravimetric analysis (TGA). The laminated composites showed excellent resistance properties against chemicals and good mechanical and electrical properties.

  17. Blood flow/pump rotation ratio as an artificial lung performance monitoring tool during extracorporeal respiratory support using centrifugal pumps.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Hirota, Adriana Sayuri; dos Santos, Edzangela Vasconcelos; Costa, Eduardo Leite Vieira; Azevedo, Luciano Cesar Pontes

    2015-01-01

    To analyze the correlations of the blood flow/pump rotation ratio and the transmembrane pressure, CO2 and O2 transfer during the extracorporeal respiratory support. Five animals were instrumented and submitted to extracorporeal membrane oxygenation in a five-step protocol, including abdominal sepsis and lung injury. This study showed that blood flow/pump rotations ratio variations are dependent on extracorporeal membrane oxygenation blood flow in a positive logarithmic fashion. Blood flow/pump rotation ratio variations are negatively associated with transmembrane pressure (R2 = 0.5 for blood flow = 1500mL/minute and R2 = 0.4 for blood flow = 3500mL/minute, both with p 6L/minute, p = 0.006), and the blood flow/pump rotation ratio is not associated with O2 transfer variations (R2 = 0.01 for blood flow = 1500mL/minute, p = 0.19, and R2 = - 0.01 for blood flow = 3500 mL/minute, p = 0.46). Blood flow/pump rotation ratio variation is negatively associated with transmembrane pressure and positively associated with CO2 transfer in this animal model. According to the clinical situation, a decrease in the blood flow/pump rotation ratio can indicate artificial lung dysfunction without the occurrence of hypoxemia.

  18. Rheological properties of flowable resin composites and pit and fissure sealants.

    Science.gov (United States)

    Beun, Sébastien; Bailly, Christian; Devaux, Jacques; Leloup, Gaëtane

    2008-04-01

    The purpose of this research was to determine the viscoelastic properties of commercially available flowable resin composites and resin-based pit and fissure sealants. The weight percentage of filler particles and the morphology of the filler particles were also investigated. Eight flowable resin composites (Admira Flow, Filtek Flow, FlowLine, Grandio Flow, Point-4 Flowable, Revolution Formula 2, Tetric Flow and X-Flow) and four pit and fissure sealants (Clinpro, Delton FS+, Estiseal F and Guardian Seal) were tested. Rheological measurements were performed using a dynamic oscillation rheometer. The filler weight content was determined by thermogravimetric analysis (TGA) and the morphology of the particles was investigated by scanning-electron microscopy (SEM). Flowable resin composites are non-Newtonian, shear-thinning materials. As the shear rate increased, the complex viscosity decreased drastically. They all showed elasticity even at the lowest frequencies. They also all showed thixotropy. Pit and fissure sealants are non-Newtonian, very low-viscosity fluids. No correlation was found between the rheological properties and the filler weight content or the particles' shape. Huge differences are observed in the viscosity and flow characteristics of flowable resin composites that can have a potential influence on their clinical behavior during handling and thus on their clinical indications. Pit and fissure sealants show very different rheological properties from one another.

  19. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  20. and phenol–formaldehyde resin

    Indian Academy of Sciences (India)

    formaldehyde resin (PFR) modified with tetraethylorthosilicate are investigated in detail. The chemical synthesis of PFR, its modification with nanometer- sized SiO2 particles created by sol–gel method and subsequent coating, enables a preparation of ...

  1. Bending characteristics of resin concretes

    Directory of Open Access Journals (Sweden)

    Ribeiro Maria Cristina Santos

    2003-01-01

    Full Text Available In this research work the influence of composition and curing conditions in bending strength of polyester and epoxy concrete is analyzed. Various mixtures of resin and aggregates were considered in view of an optimal combination. The Taguchi methodology was applied in order to reduce the number of tests, and in order to evaluate the influence of various parameters in concrete properties. This methodology is very useful for the planning of experiments. Test results, analyzed by this methodology, shown that the most significant factors affecting bending strength properties of resin concretes are the type of resin, resin content and charge content. An optimal formulation leading to a maximum bending strength was achieved in terms of material parameters.

  2. Epoxy hydantoins as matrix resins

    Science.gov (United States)

    Weiss, J.

    1983-01-01

    Tensile strength and fracture toughness of castings of the hydantoin resins cured with methylenedianiline are significantly higher than MY 720 control castings. Water absorption of an ethyl, amyl hydantoin formulation is 2.1 percent at equilibrium and Tg's are about 160 C, approximately 15 deg below the final cure temperature. Two series of urethane and ester-extended hydantoin epoxy resins were synthesized to determine the effect of crosslink density and functional groups on properties. Castings cured with methylenedianiline or with hexahydrophthalic anhydride were made from these compounds and evaluated. The glass transition temperatures, tensile strengths and moduli, and fracture toughness values were all much lower than that of the simple hydantoin epoxy resins. Using a methylene bishydantoin epoxy with a more rigid structure gave brittle, low-energy fractures, while a more flexible, ethoxy-extended hydantoin epoxy resin gave a very low Tg.

  3. Analysis of Capillary Coating Die Flow in an Optical Fiber Coating Applicator

    OpenAIRE

    Kyoungjin Kim

    2011-01-01

    Viscous heating becomes significant in the high speed resin coating process of glass fibers for optical fiber manufacturing. This study focuses on the coating resin flows inside the capillary coating die of optical fiber coating applicator and they are numerically simulated to examine the effects of viscous heating and subsequent temperature increase in coating resin. Resin flows are driven by fast moving glass fiber and the pressurization at the coating die inlet, while ...

  4. Resin glycosides from Porana duclouxii.

    Science.gov (United States)

    Ding, Wen-Bing; Zhang, Dai-Gui; Liu, Chun-Jie; Li, Guan-Hua; Li, You-Zhi

    2014-01-01

    A new intact resin glycoside (3) and two glycosidic acids (1 and 2), all having a common trisaccharide moiety and (11S)-hydroxytetradecanoic acid or (3S,11S)-dihydroxytetradecanoic acid as the aglycone, were obtained from the roots of Porana duclouxii. Their structures were elucidated by spectroscopic analyses and chemical correlations. These compounds represent the first examples of resin glycosides from the genus Porana.

  5. Karakteristik Komposit Resin Berkemampuan Mengalir

    Directory of Open Access Journals (Sweden)

    Bambang Irawan

    2015-10-01

    Full Text Available The use of resin composites as posterior restoratives has markedly increased over the past decade. The patients demand for better esthetics, concerns related to possible mercury toxicity from amalgam and improvements in resin composite materials have significantly contributed the popularity of these materials. Early problems related to composites included excessive wear, less of anatomic form, post operative sensitivity, secondary caries and marginal leakage. Marginal adaptation still remains an unavoidable problem for composite restoration, especially at the gingival wall of cervical or Class II restoration. In an attempt to improve marginal sealing, many techniques and lining materials have been designed. To reduce stress generated by polymerization shrinkage, applying and curing of resin composites in layers is often recommended. Using a thick adhesive layer or low-viscosity resin may, due to its elastic properties, serve as a flexible intermediate layer and compensate for the polymerization stress created in resin composite. Flowable composites were created by retaining the same small particle size of traditional hybrid composite but reducing the filler content and allowing the increased resin to reduce the viscosity of the mixture. Flowable composites were introduced in 1996 as liners, fissure sealants and also in tunnel preparations. They have been suggested for Class I, II, III and V cavity restorations, preventive resin restorations and composite, porcelain and amalgam repairing. Their usage as a liner under high filled resins in posterior restorations has been shown to improve the adaptation of composites and effectively achieve clinically acceptable results. This article attempts to give a broad characteristics of different types of flowable composites. 

  6. Liquid monobenzoxazine based resin system

    Science.gov (United States)

    Tietze, Roger; Nguyen, Yen-Loan; Bryant, Mark

    2014-10-07

    The present invention provides a liquid resin system including a liquid monobenzoxazine monomer and a non-glycidyl epoxy compound, wherein the weight ratio of the monobenzoxazine monomer to the non-glycidyl epoxy compound is in a range of about 25:75 to about 60:40. The liquid resin system exhibits a low viscosity and exceptional stability over an extended period of time making its use in a variety of composite manufacturing methods highly advantageous.

  7. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Tetsurou (Nitto Denko Corp., Ibaraki, Osaka (Japan)); Sawa, Toshio; Shindoh, Toshikazu

    1989-09-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author).

  8. Characteristics of resin floc dispersion of anion and cation exchange resin in precoat filter using powdered ion exchange resin

    International Nuclear Information System (INIS)

    Adachi, Tetsurou; Sawa, Toshio; Shindoh, Toshikazu.

    1989-01-01

    The filtration performance of mixed filter aid consisting of powdered anion and cation exchange resins used in the precoat filter is closely related to the characteristics of resin floc dispersion. The factors related to resin floc dispersion of anion and cation exchange resin were investigated by measuring the specific settle volume of resin floc as an evaluating index in addition to the measurement of physical, chemical and electrochemical properties of powdered ion exchange resin. The effect of adsorption of iron oxide and polymer electrolyte and of ion exchange were determined. In addition, considered floc dispersion with adsorbing iron oxide, it was assumed that the amount and filling ratio of resin floc were related to summation and multiplication of surface electric charge respectively. An experimental expression was obtained for simulation of the change of specific settle volume of resin floc by particle size, surface area, ion exchange capacity and degree of ionization of the powdered ion exchange resin. (author)

  9. Radiopacity of Methacrylate and Silorane Composite Resins Using a Digital Radiographic System.

    Science.gov (United States)

    Firoozmand, Leily Macedo; Cordeiro, Mariana Gonçalves; Da Silva, Marcos André Dos Santos; De Jesus Tavarez, Rudys Rodolfo; Matos Maia Filho, Etevaldo

    The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek ™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow) cylindrical disks (5 × 1 mm) were made and radiographed by a digital method, together with a 15-step aluminum step-wedge and a 1 mm slice of human tooth. The degree of radiopacity of each image was quantified using digital image processing. The mean values of the shades of gray of the tested materials were measured and the equivalent width of aluminum was calculated for each resin. The results of our work yielded the following radiopacity values, given here in descending order: Tetric Ceram > TPH > SDR > Z350 > Z350 flow > P90 > enamel > dentin. The radiopacity of the materials was different both for the enamel and for the dentin, except for resin P90, which was no different than enamel. In conclusion, silorane-based resin exhibited a radiopacity higher than dentin and closest to the enamel; a large portion of the methacrylate-based flow and conventional resins demonstrated greater radiopacity in comparison to dentin and enamel.

  10. Radiopacity of Methacrylate and Silorane Composite Resins Using a Digital Radiographic System

    Directory of Open Access Journals (Sweden)

    Leily Macedo Firoozmand

    2016-01-01

    Full Text Available The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow cylindrical disks (5 × 1 mm were made and radiographed by a digital method, together with a 15-step aluminum step-wedge and a 1 mm slice of human tooth. The degree of radiopacity of each image was quantified using digital image processing. The mean values of the shades of gray of the tested materials were measured and the equivalent width of aluminum was calculated for each resin. The results of our work yielded the following radiopacity values, given here in descending order: Tetric Ceram > TPH > SDR > Z350 > Z350 flow > P90 > enamel > dentin. The radiopacity of the materials was different both for the enamel and for the dentin, except for resin P90, which was no different than enamel. In conclusion, silorane-based resin exhibited a radiopacity higher than dentin and closest to the enamel; a large portion of the methacrylate-based flow and conventional resins demonstrated greater radiopacity in comparison to dentin and enamel.

  11. Analysis of vertical flow during ambient and pumped conditions in four monitoring wells at the Pantex Plant, Carson County, Texas, July-September 2008

    Science.gov (United States)

    Stanton, Gregory P.; Thomas, Jonathan V.; Stoval, Jeffery

    2009-01-01

    The Pantex Plant is a U.S. Department of Energy/National Nuclear Security Administration (USDOE/NNSA)-owned, contractor-operated facility managed by Babcock & Wilcox Technical Services Pantex, LLC (B&W Pantex) in Carson County, Texas, approximately 17 miles northeast of Amarillo. The U.S. Geological Survey, in cooperation with B&W Pantex through the USDOE/NNSA, made a series of flowmeter measurements and collected other borehole geophysical logs during July–September 2008 to analyze vertical flow in screened intervals of four selected monitoring wells (PTX01–1012, PTX06–1044, PTX06–1056, and PTX06–1068) at the Pantex Plant. Hydraulic properties (transmissivity values) of the section of High Plains (Ogallala) aquifer penetrated by the wells also were computed. Geophysical data were collected under ambient and pumped flow conditions in the four monitoring wells. Unusually large drawdowns occurred at two monitoring wells (PTX06–1044 and PTX06–1056) while the wells were pumped at relatively low rates. A decision was made to redevelop those wells, and logs were run again after redevelopment in the two monitoring wells.

  12. Dynamic thermo-mechanical properties of various flowable resin composites

    Science.gov (United States)

    Balthazard, Rémy; Vincent, Marin; Dahoun, Abdessellam; Mortier, Eric

    2016-01-01

    Background This study compared the storage modulus (E’), the loss modulus (E’’) and the loss tangent (tan δ) of various flowable resin composites. Material and Methods Grandio Flow (GRF), GrandioSo Heavy Flow (GHF), Filtek Supreme XTE (XTE) and Filtek Bulk Fill (BUL) flowable resins and Clinpro Sealant (CLI) ultra-flowable pit and fissure sealant resin were used. 25 samples were tested using a dynamical mechanical thermal analysis system in bending mode. Measurements were taken within a temperature range of 10 to 55°C. The results were statistically analyzed using mixed-effect and repeated-measure analysis of variance followed by paired multiple comparisons. Results For all the materials, the E’ values decrease with temperature, whereas the tan δ values increase. Irrespective of the temperature, GHF and GRF present E’ and E’’ values significantly higher than all the other materials and CLI presents values significantly lower than all the other materials. Observation of the values for all the materials reveals a linear progression of the tan δ values with temperature. Conclusions A variation in temperature within a physiological range generates modifications in mechanical properties without damaging the material, however. Filler content in volume terms appears to be the crucial parameter in the mechanical behavior of tested materials. Key words:Dynamic mechanical thermal analysis, elastic modulus, filler content, flowable resin composites, loss modulus, loss tangent. PMID:27957266

  13. High elastic modulus nanopowder reinforced resin composites for dental applications

    Science.gov (United States)

    Wang, Yijun

    2007-12-01

    Dental restorations account for more than $3 billion dollars a year on the market. Among them, all-ceramic dental crowns draw more and more attention and their popularity has risen because of their superior aesthetics and biocompatibility. However, their relatively high failure rate and labor-intensive fabrication procedure still limit their application. In this thesis, a new family of high elastic modulus nanopowder reinforced resin composites and their mechanical properties are studied. Materials with higher elastic modulus, such as alumina and diamond, are used to replace the routine filler material, silica, in dental resin composites to achieve the desired properties. This class of composites is developed to serve (1) as a high stiffness support to all-ceramic crowns and (2) as a means of joining independently fabricated crown core and veneer layers. Most of the work focuses on nano-sized Al2O3 (average particle size 47 nm) reinforcement in a polymeric matrix with 50:50 Bisphenol A glycidyl methacrylate (Bis-GMA): triethylene glycol dimethacrylate (TEGDMA) monomers. Surfactants, silanizing agents and primers are examined to obtain higher filler levels and enhance the bonding between filler and matrix. Silane agents work best. The elastic modulus of a 57.5 vol% alumina/resin composite is 31.5 GPa compared to current commercial resin composites with elastic modulus alumina, diamond/resin composites are studied. An elastic modulus of about 45 GPa is obtained for a 57 vol% diamond/resin composite. Our results indicate that with a generally monodispersed nano-sized high modulus filler, relatively high elastic modulus resin-based composite cements are possible. Time-dependent behavior of our resin composites is also investigated. This is valuable for understanding the behavior of our material and possible fatigue testing in the future. Our results indicate that with effective coupling agents and higher filler loading, viscous flow can be greatly decreased due to the

  14. Improving catchment discharge predictions by inferring flow route contributions from a nested-scale monitoring and model setup

    NARCIS (Netherlands)

    Van Der Velde, Y.; Rozemeijer, J. C.; De Rooij, G. H.; Van Geer, F. C.; Torfs, P. J J F; De Louw, P. G B

    2011-01-01

    Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for the estimation of flow route volumes

  15. Suitability of an MRMCE (multi-resolution minimum cross entropy) algorithm for online monitoring of a two-phase flow

    International Nuclear Information System (INIS)

    Wang, Qi; Wang, Huaxiang; Xin, Shan

    2011-01-01

    The flow regimes are important characteristics to describe two-phase flows, and measurement of two-phase flow parameters is becoming increasingly important in many industrial processes. Computerized tomography (CT) has been applied to two-phase/multi-phase flow measurement in recent years. Image reconstruction of CT often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive, especially for the case of online flow regime identification. In this paper, minimum cross entropy reconstruction based on multi-resolution processing (MRMCE) is presented for oil–gas two-phase flow regime identification. A regularized MCE solution is obtained using the simultaneous multiplicative algebraic reconstruction technique (SMART) at a coarse resolution level, where important information on the reconstructed image is contained. Then, the solution in the finest resolution is obtained by inverse fast wavelet transformation. Both computer simulation and static/dynamic experiments were carried out for typical flow regimes. Results obtained indicate that the proposed method can dramatically reduce the computational time and improve the quality of the reconstructed image with suitable decomposition levels compared with the single-resolution maximum likelihood expectation maximization (MLEM), alternating minimization (AM), Landweber, iterative least square technique (ILST) and minimum cross entropy (MCE) methods. Therefore, the MRMCE method is suitable for identification of dynamic two-phase flow regimes

  16. Non-Invasive Monitoring of Temporal and Spatial Blood Flow during Bone Graft Healing Using Diffuse Correlation Spectroscopy

    Science.gov (United States)

    Han, Songfeng; Hoffman, Michael D.; Proctor, Ashley R.; Vella, Joseph B.; Mannoh, Emmanuel A.; Barber, Nathaniel E.; Kim, Hyun Jin; Jung, Ki Won; Benoit, Danielle S. W.; Choe, Regine

    2015-01-01

    Vascular infiltration and associated alterations in microvascular blood flow are critical for complete bone graft healing. Therefore, real-time, longitudinal measurement of blood flow has the potential to successfully predict graft healing outcomes. Herein, we non-invasively measure longitudinal blood flow changes in bone autografts and allografts using diffuse correlation spectroscopy in a murine femoral segmental defect model. Blood flow was measured at several positions proximal and distal to the graft site before implantation and every week post-implantation for a total of 9 weeks (autograft n = 7 and allograft n = 10). Measurements of the ipsilateral leg with the graft were compared with those of the intact contralateral control leg. Both autografts and allografts exhibited an initial increase in blood flow followed by a gradual return to baseline levels. Blood flow elevation lasted up to 2 weeks in autografts, but this duration varied from 2 to 6 weeks in allografts depending on the spatial location of the measurement. Intact contralateral control leg blood flow remained at baseline levels throughout the 9 weeks in the autograft group; however, in the allograft group, blood flow followed a similar trend to the graft leg. Blood flow difference between the graft and contralateral legs (ΔrBF), a parameter defined to estimate graft-specific changes, was elevated at 1–2 weeks for the autograft group, and at 2–4 weeks for the allograft group at the proximal and the central locations. However, distal to the graft, the allograft group exhibited significantly greater ΔrBF than the autograft group at 3 weeks post-surgery (p flow supports established trends of delayed healing in allografts versus autografts. PMID:26625352

  17. Proof-of-principle demonstration of a virtual flow meter-based transducer for gaseous helium monitoring in particle accelerator cryogenics

    Science.gov (United States)

    Arpaia, P.; Blanco, E.; Girone, M.; Inglese, V.; Pezzetti, M.; Piccinelli, F.; Serio, L.

    2015-07-01

    A transducer based on a virtual flow meter is proposed for monitoring helium distribution and consumption in cryogenic systems for particle accelerators. The virtual flow meter allows technical and economical constraints, preventing installation of physical instruments in all the needed measurement points, to be overcome. Virtual flow meter performance for the alternative models of Samson [http://www.samson.de (2015)] and Sereg-Schlumberger [http://www.slb.com/ (2015)] is compared with the standard IEC 60534-2-1 [Industrial-process control valves—Part 2-1: Flow capacity—sizing equations for fluid flow under installed conditions (2011), https://webstore.iec.ch/publication/2461], for a large temperature range, for both gaseous and liquid helium phases, and for different pressure drops. Then, the calibration function of the transducer is derived. Finally, the experimental validation for the helium gaseous state on the test station for superconducting magnets in the laboratory SM18 [Pirotte et al., AIP Conf. Proc. 1573, 187 (2014)] at CERN is reported.

  18. Report on the 4th International Conference on monitoring, simulation, prevention and remediation of dense and debris flows - Debris Flow 2012

    Directory of Open Access Journals (Sweden)

    Daniele de Wrachien

    2012-09-01

    Full Text Available Debris and hyper-concentrated flows are amongst the most destructive of all water-related disasters. These hazards are likely to become more frequent and more important in the future due to the effects of the increase in population, urbanization, land subsidence and the impact of climate change. They affect both rural and urban environments, particularly in river basins and in mountain areas. In recent years, they have attracted more and more attention from the scientific and professional communities due to the number of lives lost, and there is growing public concern for the future. New methods and measures are required to cope with debris flow changes and to achieve a harmonious balance between the environment and economic forces.

  19. Monitoring Inflation and Emplacement During the 2014-2015 Kilauea Lava Flow With an Unmanned Aerial Vehicle

    Science.gov (United States)

    Perroy, R. L.; Turner, N.; Hon, K. A.; Rasgado, V.

    2015-12-01

    Unmanned aerial vehicles (UAVs) provide a powerful new tool for collecting high resolution on-demand spatial data over volcanic eruptions and other active geomorphic processes. These data can be used to improve hazard forecasts and emergency response efforts, and also allow users to economically and safely observe and quantify lava flow inflation and emplacement on spatially and temporally useful scales. We used a small fixed-wing UAV with a modified point-and-shoot camera to repeatedly map the active front of the 2014-2015 Kīlauea lava flow over a one-month period in late 2014, at times with a two-hour repeat interval. An additional subsequent flight was added in July, 2015. We used the imagery from these flights to generate a time-series of 5-cm resolution RGB and near-infrared orthoimagery mosaics and associated digital surface models using structure from motion. Survey-grade positional control was provided by ground control points with differential GPS. Two topographic transects were repeatedly surveyed across the flow surface, contemporaneously with UAV flights, to independently confirm topographic changes observed in the UAV-derived surface models. Vertical errors were generally 10 cm. Inside our 50 hectare study site, the flow advanced at a rate of 0.47 hectares/day during the first three weeks of observations before abruptly stalling out 4 m. New outbreak areas, both on the existing flow surface and along the flow margins, were readily mapped across the study area. We detected sinuous growing inflation ridges within the flow surface that correlated with subsequent outbreaks of new lava, suggesting that repeat UAV flights can provide a means of better predicting pahoehoe lava flow behavior over flat or uneven topography. Our results show that UAVs can generate accurate and digital surface models quickly and inexpensively over rapidly changing active pahoehoe lava flows.

  20. [Separation and purification of proanthocyanidins from rose by macroporous resins].

    Science.gov (United States)

    Yao, Yu-cui; Li, Xiang-rong

    2008-08-01

    To study the separation and purification technology for proanthocyanidins from rose and establish the best operating conditions. Evaluated by static adsorption capacity and elution ratio, five types of macroporous resins including D101, D1300, NKA, AB-8, NKA-II were tested to separate and purify proanthocyanidins. And evaluated by product purity, the concentration of extract sample, pH of extract sample, concentration of eluant and flow rate of elution had been investigated. D101 type macroporous resin showed the best property and was suitable for purifying proanthocyanidins from rose. The best operating conditions were as follows: 1.25 mg/ml as the concentration of extract sample, 2 as the pH value of extract sample, 70% ethanol equeous solution as the eluant and 2 ml/min as the flow rate of elution. This study can supply a method to separate and purify proanthocyanidins from rose.

  1. Real-time isotope monitoring network at the Biosphere 2 Landscape Evolution Observatory resolves meter-to-catchment scale flow dynamics

    Science.gov (United States)

    Volkmann, T. H. M.; Van Haren, J. L. M.; Kim, M.; Harman, C. J.; Pangle, L.; Meredith, L. K.; Troch, P. A.

    2017-12-01

    Stable isotope analysis is a powerful tool for tracking flow pathways, residence times, and the partitioning of water resources through catchments. However, the capacity of stable isotopes to characterize catchment hydrological dynamics has not been fully exploited as commonly used methodologies constrain the frequency and extent at which isotopic data is available across hydrologically-relevant compartments (e.g. soil, plants, atmosphere, streams). Here, building upon significant recent developments in laser spectroscopy and sampling techniques, we present a fully automated monitoring network for tracing water isotopes through the three model catchments of the Landscape Evolution Observatory (LEO) at the Biosphere 2, University of Arizona. The network implements state-of-the-art techniques for monitoring in great spatiotemporal detail the stable isotope composition of water in the subsurface soil, the discharge outflow, and the atmosphere above the bare soil surface of each of the 330-m2 catchments. The extensive valving and probing systems facilitate repeated isotope measurements from a total of more than five-hundred locations across the LEO domain, complementing an already dense array of hydrometric and other sensors installed on, within, and above each catchment. The isotope monitoring network is operational and was leveraged during several months of experimentation with deuterium-labelled rain pulse applications. Data obtained during the experiments demonstrate the capacity of the monitoring network to resolve sub-meter to whole-catchment scale flow and transport dynamics in continuous time. Over the years to come, the isotope monitoring network is expected to serve as an essential tool for collaborative interdisciplinary Earth science at LEO, allowing us to disentangle changes in hydrological behavior as the model catchments evolve in time through weathering and colonization by plant communities.

  2. Continuous ‘Passive’ flow-proportional monitoring of drainage using a new modified Sutro weir (MSW) unit

    DEFF Research Database (Denmark)

    Vendelboe, Anders Lindblad; Rozemeijer, Joachim; de Jonge, Lis Wollesen

    2016-01-01

    controlled laboratory condition was needed before interpretation of the monitoring results was possible. The MSW does not require a shed, electricity, or maintenance. This enables largescale monitoring of contaminant loads via tile drains, which can improve contaminant transport models and yield valuable...... information for the selection and evaluation of mitigation options to improve water quality.Results from this type of monitoring can provide data for the evaluation and optimisation of best management practices in agriculture in order to produce the highest yield without water quality and recipient surface...

  3. Resin technologies: construction and staining of resin TMA's.

    Science.gov (United States)

    Howat, William J; Wilson, Susan J

    2010-01-01

    The traditional formaldehyde-fixed paraffin-embedded tissue, and therefore the tissue microarrays created from it, provide good morphology but with a compromised antigenicity when compared to frozen tissue. In contrast, while solving the issue of antigenicity, frozen tissue suffers from a lack of morphology. We have demonstrated that tissue microarrays constructed in glycol methacrylate resin, when combined with a cold acetone fixation step, have been able to combine the superior morphology of resin-embedded sections with the superior antigenicity of frozen tissue for prospectively collected material.

  4. In vivo flow cytometry visualizes the effects of tumor resection on metastasis by real-time monitoring of rare circulating cancer cells

    Science.gov (United States)

    Wei, Dan; Fan, Zhichao; Wang, Xueding; Wei, Xunbin

    2013-02-01

    Hepatocellular carcinoma (HCC) is one of the most common malignancies in the world, with approximately 1,000,000 cases reported every year. The fate of circulating tumor cells (CTCs) is an important determinant of metastasis and recurrence, which lead to most deaths in HCC. Therefore, quantification of CTCs proves to be an emerging tool for diagnosing, stratifying and monitoring patients with metastatic diseases. In vivo flow cytometry (IVFC) has the capability to monitor the dynamics of fluorescently labeled CTCs continuously and non-invasively. Here, we combine IVFC technique and a GFP-transfected HCC orthotopic metastatic tumor model to monitor CTC dynamics. Our IVFC has ~1.8-fold higher sensitivity than whole blood analysis by conventional flow cytometry. We find out a significant difference of CTC dynamics between orthotopic and subcutaneous (s.c.) tumor models. We also investigate whether liver resection promotes or restricts hematogenous metastasis in advanced HCC. Our result shows that the number of CTCs and early metastases decreases after the resection. CTC dynamics is correlated with tumor growth in our orthotopic tumor model. The number and size of distant metastases correspond to CTC dynamics. The novel IVFC technique combined with orthotopic tumor models might provide insights to tumor hematogenous metastasis and guidance to cancer therapy.

  5. Characterization of Composite Fan Case Resins

    Science.gov (United States)

    Dvoracek, Charlene M.

    2004-01-01

    The majority of commercial turbine engines that power today s aircraft use a large fan driven by the engine core to generate thrust which dramatically increases the engine s efficiency. However, if one of these fan blades fails during flight, it becomes high energy shrapnel, potentially impacting the engine or puncturing the aircraft itself and thus risking the lives of passengers. To solve this problem, the fan case must be capable of containing a fan blade should it break off during flight. Currently, all commercial fan cases are made of either just a thick metal barrier or a thinner metal wall surrounded by Kevlar-an ultra strong fiber that elastically catches the blade. My summer 2004 project was to characterize the resins for a composite fan case that will be lighter and more efficient than the current metal. The composite fan case is created by braiding carbon fibers and injecting a polymer resin into the braid. The resin holds the fibers together, so at first using the strongest polymer appears to logically lead to the strongest fan case. Unfortunately, the stronger polymers are too viscous when melted. This makes the manufacturing process more difficult because the polymer does not flow as freely through the braid, and the final product is less dense. With all of this in mind, it is important to remember that the strength of the polymer is still imperative; the case must still contain blades with high impact energy. The research identified which polymer had the right balance of properties, including ease of fabrication, toughness, and ability to transfer the load to the carbon fibers. Resin deformation was studied to better understand the composite response during high speed impact. My role in this research was the testing of polymers using dynamic mechanical analysis and tensile, compression, and torsion testing. Dynamic mechanical analysis examines the response of materials under cyclic loading. Two techniques were used for dynamic mechanical analysis

  6. A Compact Tunable Diode Laser Absorption Spectrometer to Monitor CO2 at 2.7 µm Wavelength in Hypersonic Flows

    Directory of Open Access Journals (Sweden)

    Raphäel Vallon

    2010-06-01

    Full Text Available Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship’s Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.

  7. Ultrasonic and thermo-kinetic characterization of curing epoxy resin

    OpenAIRE

    Ali, Sheikh Mohammod

    2013-01-01

    This study combines cure kinetics modelling and thermal and ultrasonic cure monitoring to characterize the cure state of a complex commercial modified epoxy thermosetting system of industrial importance containing two epoxies, diethylene triamine hardener, external catalyst, aliphatic reactive diluent, and mica. Both catalyst and reactive diluent in the formulation of two epoxy resin mixture keep this complex system odd from others and to some extent a new one to report cure kinetics to the b...

  8. Epoxy Resins in Electron Microscopy

    Science.gov (United States)

    Finck, Henry

    1960-01-01

    A method of embedding biological specimens in araldite 502 (Ciba) has been developed for materials available in the United States. Araldite-embedded tissues are suitable for electron microscopy, but the cutting qualities of the resin necessitates more than routine attention during microtomy. The rather high viscosity of araldite 502 also seems to be an unnecessary handicap. The less viscous epoxy epon 812 (Shell) produces specimens with improved cutting qualities, and has several features—low shrinkage and absence of specimen damage during cure, minimal compression of sections, relative absence of electron beam-induced section damage, etc.—which recommends it as a routine embedding material. The hardness of the cured resin can be easily adjusted by several methods to suit the materials embedded in it. Several problems and advantages of working with sections of epoxy resins are also discussed. PMID:13822825

  9. Process for Molding Nonreinforced (Neat) Resins

    Science.gov (United States)

    Dickerson, G. E.

    1983-01-01

    Void free moldings obtained for neat, condensation, thermosetting resins. Thermally and mechanically treat resin prior to molding to reduce amount of volatiles. With volatiles reduced molding temperature and pressure are applied in way to drive out remaining volatiles during molding.

  10. 21 CFR 172.280 - Terpene resin.

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION (CONTINUED) FOOD ADDITIVES PERMITTED FOR DIRECT ADDITION TO FOOD FOR HUMAN CONSUMPTION Coatings, Films and Related Substances § 172.280 Terpene resin. The food additive terpene resin may be safely used...

  11. Action of ionizing radiation on epoxy resins

    Energy Technology Data Exchange (ETDEWEB)

    Van de Voorde, M. E.

    1970-12-01

    The resistance of classical and experimental epoxy resins to irradiation was studied. The resistance to irradiation of epoxy resins of diverse compositions as well as the development of resins having a radioresistance that approaches that of certain ceramics are discussed. Sources of irradiation and the techniques of dosimetry used are described. The structures of certain epoxy resins and of hardeners are given. The preparation of these resins and their physical properties is described. The effects of radiation on epoxy resins, as well as conditions of irradiation, and suggested mechanisms for degradation of the irradiated resins are discussed. The relationship between chemical structure of the resins and their physical properties is evaluated. (115 references) (JCB)

  12. Method for loading resin beds

    International Nuclear Information System (INIS)

    Notz, K.J.; Rainey, R.H.; Greene, C.W.; Shockley, W.E.

    1978-01-01

    An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145 to 200 0 C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145 0 C with a second aqueous component to provide a gaseous phase containing HNO 3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate

  13. Uranium sorption by tannin resins

    International Nuclear Information System (INIS)

    Olivares Rieumont, S.; Martinez Luzardo, J.; Torres Hernandez, J.; Lima Cazorla, D. de la Rosa.

    1998-01-01

    The sorption of uranium by immobilised Eucalyptus Saligna Sm. and Lysiloma latisiliqua L tannins was investigated. Immobilization condition were analyzed. These resins resulted suitable adsorbent for the concentration of uranium from aqueous systems. The sorption of uranium is pH dependent. At pH 5.5 maximum in sorption capacity is registered. The presence of appreciable amount of sodium chloride do not have any effect on uranium removal. Carbonate and calcium ions in concentrations similar to these that could be found in sea water and other natural water do not decrease the uranium uptake. Tannin resins can be used several times without an appreciable decay of their sorption capacity

  14. Using multi-parameter flow cytometry to monitor the yeast Rhodotorula glutinis CCMI 145 batch growth and oil production towards biodiesel.

    Science.gov (United States)

    da Silva, Teresa Lopes; Feijão, Daniela; Reis, Alberto

    2010-12-01

    Multi-parameter flow cytometry was used to monitor cell intrinsic light scatter, viability, and lipid content of Rhodotorula glutinis CCMI 145 cells grown in shake flasks. Changes in the side light scatter and forward light scatter were detected during the yeast batch growth, which were attributed to the different yeast growth phases. A progressive increase in the proportion of cells stained with PI (cells with permeabilized cytoplasmic membrane) was observed during the yeast growth, attaining 79% at the end of the fermentation. A high correlation between the Nile Red fluorescence intensity measured by flow cytometry and total lipid content assayed by the traditional gravimetric lipid analysis was found for this yeast, making this method a suitable and quick technique for the screening of yeast strains for lipid production and optimization of biofuel production bioprocesses. Medium growth optimization for enhancement of the yeast oil production is now in progress.

  15. Simulation and System Analysis of Flow Pulsation at Normal and Emergency for Advanced On-line Monitoring and Control of NPP

    International Nuclear Information System (INIS)

    Proskouriakov, K.N.; Moukhine, V.S.

    2002-01-01

    In addition to investigation of thermal-hydraulic processes on NPP with use of computer codes the new system analysis of flow pulsation is worked out. System analysis shows that properties of heat rejection circuits of NPP as oscillatory system are not equal the sum of properties of its separate elements but gives the new properties which must be taken into account. Methods have been worked out for calculating and identifying the sources of thermal-hydraulic disturbances are intended to improve the means of early diagnostics of anomalies in the technological process, to forecast their development, to improve the efficiency of overhauling operations and safety in operation, and also to create advanced on-line monitoring and control of NPP. Conception of the control system development presents. Proposal for main topics R and D areas for advanced NPP monitoring, diagnostic and control are identified. (authors)

  16. Nonlinear Inelastic Mechanical Behavior Of Epoxy Resin Polymeric Materials

    Science.gov (United States)

    Yekani Fard, Masoud

    Polymer and polymer matrix composites (PMCs) materials are being used extensively in different civil and mechanical engineering applications. The behavior of the epoxy resin polymers under different types of loading conditions has to be understood before the mechanical behavior of Polymer Matrix Composites (PMCs) can be accurately predicted. In many structural applications, PMC structures are subjected to large flexural loadings, examples include repair of structures against earthquake and engine fan cases. Therefore it is important to characterize and model the flexural mechanical behavior of epoxy resin materials. In this thesis, a comprehensive research effort was undertaken combining experiments and theoretical modeling to investigate the mechanical behavior of epoxy resins subject to different loading conditions. Epoxy resin E 863 was tested at different strain rates. Samples with dog-bone geometry were used in the tension tests. Small sized cubic, prismatic, and cylindrical samples were used in compression tests. Flexural tests were conducted on samples with different sizes and loading conditions. Strains were measured using the digital image correlation (DIC) technique, extensometers, strain gauges, and actuators. Effects of triaxiality state of stress were studied. Cubic, prismatic, and cylindrical compression samples undergo stress drop at yield, but it was found that only cubic samples experience strain hardening before failure. Characteristic points of tensile and compressive stress strain relation and load deflection curve in flexure were measured and their variations with strain rate studied. Two different stress strain models were used to investigate the effect of out-of-plane loading on the uniaxial stress strain response of the epoxy resin material. The first model is a strain softening with plastic flow for tension and compression. The influence of softening localization on material behavior was investigated using the DIC system. It was found that

  17. The effect of bed roughness on the free surface of an open channel flow and implications for remotely monitoring river discharge

    Science.gov (United States)

    Johnson, Erika; Cowen, Edwin

    2013-11-01

    The effect of increased bed roughness on the free surface turbulence signature of an open channel flow is investigated with the goal of incorporating the findings into a methodology to remotely monitor volumetric flow rates. Half of a wide (B = 2 m) open channel bed is covered with a 3 cm thick layer of loose gravel (D50 = 0.6 cm). Surface PIV (particle image velocimetry) experiments are conducted for a range of flow depths (B/H = 10-30) and Reynolds numbers (ReH = 10,000-60,000). It is well established that bed roughness in wall-bounded flows enhances the vertical velocity fluctuations (e.g. Krogstad et al. 1992). When the vertical velocity fluctuations approach the free surface they are redistributed (e.g. Cowen et al. 1995) to the surface parallel component directions. It is anticipated and confirmed that the interaction of these two phenomena result in enhanced turbulence at the free surface. The effect of the rough bed on the integral length scales and the second order velocity structure functions calculated at the free surface are investigated. These findings have important implications for developing new technologies in stream gaging.

  18. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert, George W. (Harrisonville, MO); Hand, Thomas E. (Lee' s Summit, MO); DeLaurentiis, Gary M. (Jamestown, CA)

    2008-11-18

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  19. Method of removing contaminants from plastic resins

    Energy Technology Data Exchange (ETDEWEB)

    Bohnert,George W. (Harrisonville, MO); Hand,Thomas E. (Lee' s Summit, MO); Delaurentiis,Gary M. (Jamestown, CA)

    2007-08-07

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  20. Method for removing contaminants from plastic resin

    Science.gov (United States)

    Bohnert, George W.; Hand, Thomas E.; DeLaurentiis, Gary M.

    2008-12-30

    A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

  1. A study on the radiopacity of cavity lining materials for posterior composite resin restoration

    International Nuclear Information System (INIS)

    Moon, Joo Hoon; Choi, Eui Hwan

    2000-01-01

    The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Flowable resin) for posterior composite resin restoration. Resin-modified glass ionomer cement (Fuji II LC, Vitrebond (TM)), Compomers (Dyract , Compoglass, F2000, Dyract(R) flow Compoglass Flow) and Flowable resins (Tetric (R) flow, Aeliteflo (TM) Revolution (TM)) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtained from conventional radiograph and NIH image program. All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract (R), Compoglass, F2000, Dyract (R) flow, Compoglass Flow) and Vitrebond (TM), Tetric (R) flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution (TM) were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric (R) flow were greater than those of Revolution (TM), Aeliteflo (TM) or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  2. A study on the radiopacity of cavity lining materials for posterior composite resin restoration

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Joo Hoon [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of); Choi, Eui Hwan [Dept. of Conservative Dentistry, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    2000-12-15

    The aim of this study was to determine the relative radiopacities of cavity lining materials (Resin-modified Glass Ionomer cement, Compomer and Flowable resin) for posterior composite resin restoration. Resin-modified glass ionomer cement (Fuji II LC, Vitrebond (TM)), Compomers (Dyract , Compoglass, F2000, Dyract(R) flow Compoglass Flow) and Flowable resins (Tetric (R) flow, Aeliteflo (TM) Revolution (TM)) were used. Five specimens of 5 mm in diameter and 2 mm thick were fabricated with each material. Human molars were horizontally sectioned 2 mm thick to include both enamel and dentin. The radiopacities of enamel, dentin, cavity lining materials, aluminum step wedge were obtained from conventional radiograph and NIH image program. All the tested lining materials showed levels of radiopacity the same as or greater than that of dentin. All compomer tested (Dyract (R), Compoglass, F2000, Dyract (R) flow, Compoglass Flow) and Vitrebond (TM), Tetric (R) flow were more radiopaque than enamel. The radiopacities of Fuji II LC and Revolution (TM) were between enamel and dentin and resin-modified glass ionomer cement, Compomer and Tetric (R) flow were greater than those of Revolution (TM), Aeliteflo (TM) or dentin. The level of radiopacity of the tested materials was variable; those with low radiopacity should be avoided in class II restorations, where a clear determination of recurrent caries by the examining clinician could be compromised. Clinician should be able to distinguish these cavity lining materials radiographically from recurrent decay, voids, gaps, or other defects that lead to clinical failure. Utilization of materials ranked more radiopaque than enamel would enable clinicians to distinguish the lining material from tooth structure.

  3. Improving catchment discharge predictions by inferring flow route contributions from a nested-scale monitoring and model setup

    Directory of Open Access Journals (Sweden)

    Y. van der Velde

    2011-03-01

    Full Text Available Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for the estimation of flow route volumes and for predictions of catchment discharge. In order to relate field-site measurements to the catchment-scale an upscaling approach is introduced that assumes that scale differences in flow route fluxes originate from differences in the relationship between groundwater storage and the spatial structure of the groundwater table. This relationship is characterized by the Groundwater Depth Distribution (GDD curve that relates spatial variation in groundwater depths to the average groundwater depth. The GDD-curve was measured for a single field site (0.009 km2 and simple process descriptions were applied to relate groundwater levels to flow route discharges. This parsimonious model could accurately describe observed storage, tube drain discharge, overland flow and groundwater flow simultaneously with Nash-Sutcliff coefficients exceeding 0.8. A probabilistic Monte Carlo approach was applied to upscale field-site measurements to catchment scales by inferring scale-specific GDD-curves from the hydrographs of two nested catchments (0.4 and 6.5 km2. The estimated contribution of tube drain effluent (a dominant source for nitrates decreased with increasing scale from 76–79% at the field-site to 34–61% and 25–50% for both catchment scales. These results were validated by demonstrating that a model conditioned on nested-scale measurements improves simulations of nitrate loads and predictions of extreme discharges during validation periods compared to a model that was conditioned on catchment discharge only.

  4. Diterpene resin acids in conifers.

    Science.gov (United States)

    Keeling, Christopher I; Bohlmann, Jörg

    2006-11-01

    Diterpene resin acids are a significant component of conifer oleoresin, which is a viscous mixture of terpenoids present constitutively or inducibly upon herbivore or pathogen attack and comprises one form of chemical resistance to such attacks. This review focuses on the recent discoveries in the chemistry, biosynthesis, molecular biology, regulation, and biology of these compounds in conifers.

  5. Occupational exposure to epoxy resins

    NARCIS (Netherlands)

    Terwoert, J.; Kersting, K.

    2014-01-01

    Products based on epoxy resins as a binder have become popular in various settings, among which the construction industry and in windmill blade production, as a result of their excellent technical properties. However, due to the same properties epoxy products are a notorious cause of allergic skin

  6. Physicochemical Properties of Epoxy Resin-Based and Bioceramic-Based Root Canal Sealers.

    Science.gov (United States)

    Lee, Ju Kyung; Kwak, Sang Won; Ha, Jung-Hong; Lee, WooCheol; Kim, Hyeon-Cheol

    2017-01-01

    Three bioceramic sealers (EndoSequence BC sealer, EndoSeal MTA, and MTA Fillapex) and three epoxy resin-based sealers (AH-Plus, AD Seal, and Radic-Sealer) were tested to evaluate the physicochemical properties: flow, final setting time, radiopacity, dimensional stability, and pH change. The one-way ANOVA and Tukey's post hoc test were used to analyze the data ( P = 0.05). The MTA Fillapex sealer had a highest flow and the BC Sealer presented a flow significantly lower than the others ( P pH in all evaluation periods. Set samples of 3 epoxy resin-based sealers and EndoSeal MTA presented a significant increase of pH over experimental time for 4 weeks. In conclusion, the bioceramic sealer and epoxy resin-based sealers showed clinical acceptable physicochemical properties, but BC Sealer and MTA Fillapex were not set completely.

  7. Large scale purification of puerarin from Puerariae Lobatae Radix through resins adsorption and acid hydrolysis.

    Science.gov (United States)

    Guo, Hai-Dong; Zhang, Qing-Feng; Chen, Ji-Guang; Shangguang, Xin-Cheng; Guo, Yu-Xian

    2015-02-01

    Puerarin is the major isoflavone of Puerariae Lobatae Radix. A method for large scale purification of puerarin was developed through resins adsorption and acid hydrolysis. The adsorption properties of six macroporous resins (D101, S-8, H103, X-5, HPD600, AB-8) were compared through the adsorption kinetics and equilibrium adsorption isotherms. Results showed that H103 resin had the best adsorption rate and capacity. The mass transfer zone motion model was further used for analyzing the fixed bed adsorption of H103 resin. Its length of mass transfer zone with 2mg/ml of puerarin in water and 10% ethanol at flow rate of 10ml/min were 41.6 and 47.5cm, while the equilibrium adsorption capacity was 165.03 and 102.88mg/g, respectively. By using 75% ethanol, puerarin could be well desorbed from the resin with recovery of 97.4%. Subsequently, H103 resin was successfully used for puerarin purification from Puerariae Lobatae Radix. The content of total isoflavones and puerarin in the resin adsorption product were 69.25% and 41.78%, respectively, which were about three times increased compared to the crude extract. Then, the product was hydrolyzed by 2.5M HCl at 90°C for 1h. Puerarin with purity of 90% and a byproduct daidzein with purity of 78% were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. [Studies on the separation and purificaton of pumiloside from Nauclea officinalis by macroreticular resin].

    Science.gov (United States)

    Xuan, Wei-dong; Bian, Jun; Chen, Hai-sheng

    2007-10-01

    To investigate the technological parameters and the process for separation and purification of pumiloside (PML) from Nauclea officinalis Pierrc ex Pitard by macroreticular resin. PML was extracted by hot water, and the content of PML was determinated by HPLC method. The static capacity absorption, static elution ratios of five types of resin were studied respectively, and were compared to evaluate their absorption and desorption effect to PML. And then the absorption capacity, elution solution and elution volume of the AB-8 resin were researched to set up the optimum separation process for PML. Finally, PML was recrysallized from MeOH and identified by spectra analysis. The AB-8 resin had the best absorptive and separative properties to PML. The dynamic absorption ratio was 2.44 mg/g. The applicable process was as follows: the water extracted solution of Nauclea officinalis flow through the resin column repeatedly, after being eluted with 6BV of distilled water, the resin column was eluted with 4BV 30% ethanol, the 30% ethanol fraction was combined and the solvent was recovered in vacuum. The precipitation was filtered and recrysallized from MeOH to give pure PML. The yield of PML was 75.1%, and the product purity was up to 99.5%. AB-8 resin shows better comprehensive absorption property. It can be used for separation and purification of PML from Nauclea officinalis successfully.

  9. Nested-scale discharge and groundwater level monitoring to improve predictions of flow route discharges and nitrate loads

    NARCIS (Netherlands)

    Velde, Y. van der; Rozemeijer, J.C.; Rooij, G.H.de; Geer, F.C. van; Torfs, P.J.J.F.; Louw, P.G.B. de

    2010-01-01

    Identifying effective measures to reduce nutrient loads of headwaters in lowland catchments requires a thorough understanding of flow routes of water and nutrients. In this paper we assess the value of nested-scale discharge and groundwater level measurements for predictions of catchment-scale

  10. MONITORING INTERNATIONAL MIGRATION FLOWS IN EUROPE - TOWARDS A STATISTICAL-DATA BASE COMBINING DATA FROM DIFFERENT SOURCES

    NARCIS (Netherlands)

    WILLEKENS, F

    1994-01-01

    The paper reviews techniques developed in demography, geography and statistics that are useful for bridging the gap between available data on international migration flows and the information required for policy making and research. The basic idea of the paper is as follows: to establish a coherent

  11. Probabilistic commodity-flow-based focusing of monitoring activities to facilitate early detection of Phytophthora ramorum outbreaks

    Science.gov (United States)

    Steven C. McKelvey; William D. Smith; Frank Koch

    2012-01-01

    This project summary describes a probabilistic model developed with funding support from the Forest Health Monitoring Program of the Forest Service, U.S. Department of Agriculture (BaseEM Project SO-R-08-01). The model has been implemented in SODBuster, a standalone software package developed using the Java software development kit from Sun Microsystems.

  12. When Are Mobile Phones Useful for Water Quality Data Collection? An Analysis of Data Flows and ICT Applications among Regulated Monitoring Institutions in Sub-Saharan Africa.

    Science.gov (United States)

    Kumpel, Emily; Peletz, Rachel; Bonham, Mateyo; Fay, Annette; Cock-Esteb, Alicea; Khush, Ranjiv

    2015-09-02

    Water quality monitoring is important for identifying public health risks and ensuring water safety. However, even when water sources are tested, many institutions struggle to access data for immediate action or long-term decision-making. We analyzed water testing structures among 26 regulated water suppliers and public health surveillance agencies across six African countries and identified four water quality data management typologies. Within each typology, we then analyzed the potential for information and communication technology (ICT) tools to facilitate water quality information flows. A consistent feature of all four typologies was that testing activities occurred in laboratories or offices, not at water sources; therefore, mobile phone-based data management may be most beneficial for institutions that collect data from multiple remote laboratories. We implemented a mobile phone application to facilitate water quality data collection within the national public health agency in Senegal, Service National de l'Hygiène. Our results indicate that using the phones to transmit more than just water quality data will likely improve the effectiveness and sustainability of this type of intervention. We conclude that an assessment of program structure, particularly its data flows, provides a sound starting point for understanding the extent to which ICTs might strengthen water quality monitoring efforts.

  13. When Are Mobile Phones Useful for Water Quality Data Collection? An Analysis of Data Flows and ICT Applications among Regulated Monitoring Institutions in Sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Emily Kumpel

    2015-09-01

    Full Text Available Water quality monitoring is important for identifying public health risks and ensuring water safety. However, even when water sources are tested, many institutions struggle to access data for immediate action or long-term decision-making. We analyzed water testing structures among 26 regulated water suppliers and public health surveillance agencies across six African countries and identified four water quality data management typologies. Within each typology, we then analyzed the potential for information and communication technology (ICT tools to facilitate water quality information flows. A consistent feature of all four typologies was that testing activities occurred in laboratories or offices, not at water sources; therefore, mobile phone-based data management may be most beneficial for institutions that collect data from multiple remote laboratories. We implemented a mobile phone application to facilitate water quality data collection within the national public health agency in Senegal, Service National de l’Hygiène. Our results indicate that using the phones to transmit more than just water quality data will likely improve the effectiveness and sustainability of this type of intervention. We conclude that an assessment of program structure, particularly its data flows, provides a sound starting point for understanding the extent to which ICTs might strengthen water quality monitoring efforts.

  14. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  15. Mechanical characterisation of agarose-based chromatography resins for biopharmaceutical manufacture.

    Science.gov (United States)

    Nweke, Mauryn C; McCartney, R Graham; Bracewell, Daniel G

    2017-12-29

    Mechanical characterisation of agarose-based resins is an important factor in ensuring robust chromatographic performance in the manufacture of biopharmaceuticals. Pressure-flow profiles are most commonly used to characterise these properties. There are a number of drawbacks with this method, including the potential need for several re-packs to achieve the desired packing quality, the impact of wall effects on experimental set up and the quantities of chromatography media and buffers required. To address these issues, we have developed a dynamic mechanical analysis (DMA) technique that characterises the mechanical properties of resins based on the viscoelasticity of a 1ml sample of slurry. This technique was conducted on seven resins with varying degrees of mechanical robustness and the results were compared to pressure-flow test results on the same resins. Results show a strong correlation between the two techniques. The most mechanically robust resin (Capto Q) had a critical velocity 3.3 times higher than the weakest (Sepharose CL-4B), whilst the DMA technique showed Capto Q to have a slurry deformation rate 8.3 times lower than Sepharose CL-4B. To ascertain whether polymer structure is indicative of mechanical strength, scanning electron microscopy images were also used to study the structural properties of each resin. Results indicate that DMA can be used as a small volume, complementary technique for the mechanical characterisation of chromatography media. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  16. [Study on purification of total flavones from Trollius ledebouri by macroporous resin].

    Science.gov (United States)

    Zhou, Xin; Fan, Guo-rong

    2009-09-01

    To study the optimal technologies for the purification of total flavones from Trollius ledebouri with macroporous resin. Static and dynamic adsorption-desorption methods were adopted to choose the optimal type of resin. The adsorption function of D101 macroporous resin and the effects of sample concentration, pH, flow rate and eluant etc. were studied. Then the orthogonal design L9 (3(4)) was used to select the optimum purification process conditions. The appropriate technological conditions were as follows: the sample concentration was 0.5 g/mL, pH 6.0, the ratio of sample to D101 macroporous resin was 1:1 (W/W), 4 BV of water was used as purificant and 6 BV of 30% alcohol was used as eluant. Under these conditions, the average content of total flavonoids extract was over 60%.

  17. EDF specifications on nuclear grade resins

    International Nuclear Information System (INIS)

    Mascarenhas, Darren; Gressier, Frederic; Taunier, Stephane; Le-Calvar, Marc; Ranchoux, Gilles; Marteau, Herve; Labed, Veronique

    2012-09-01

    Ion exchange resins are widely used across EDF, especially within the nuclear division for the purification of water. Important applications include primary circuit, secondary circuit and effluent treatment, which require high quality nuclear grade resins to retain the dissolved species, some of which may be radioactive. There is a need for more and more efficient purification in order to decrease worker dose during maintenance but also to decrease volumes of radioactive resin waste. Resin performance is subject to several forms of degradation, including physical, chemical, thermal and radioactive, therefore appropriate resin properties have to be selected to reduce such effects. Work has been done with research institutes, manufacturers and on EDF sites to select these properties, create specifications and to continuously improve on these specifications. An interesting example of research regarding resin performance is the resin degradation under irradiation. Resins used in the CVCS circuit of EDF nuclear power plants are subject to irradiation over their lifetime. A study was carried out on the effects of total integrated doses of 0.1, 1 and 10 MGy on typically used EDF mixed bed resins in a 'mini-CVCS' apparatus to simultaneously test actual primary circuit fluid. The tests confirmed that the resins still perform efficiently after a typical CVCS radiation dose. Certain resins also need additional specifications in order to maintain the integrity of the particular circuits they are used in. Recently, EDF has updated its requirements on these high purity nuclear grade resins, produced generic doctrines for all products and materials used on site which include resins of all grades, and as a result have also updated a guide on recommended resin usage for the French fleet of reactors. An overview of the evolutions will be presented. (authors)

  18. Interactions between resin monomers and commercial composite resins with human saliva derived esterases.

    Science.gov (United States)

    Jaffer, F; Finer, Y; Santerre, J P

    2002-04-01

    Cholesterol esterase (CE) and pseudocholinesterase (PCE) have been reported to degrade commercial and model composite resins containing bisphenylglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) or the latter in combination with urethane modified BisGMA monomer systems. In addition, human saliva has been shown to contain esterase like activities similar to CE and PCE. Hence, it was the aim of the current study to determine to what extent human saliva could degrade two common commercial composite resins (Z250 from 3M Inc. and Spectrum TPH from L.D. Caulk) which contain the above monomer systems. Saliva samples from different volunteers were collected, processed, pooled, and freeze-dried. TEGDMA and BisGMA monomers were incubated with human saliva derived esterase activity (HSDEA) and their respective hydrolysis was monitored using high performance liquid chromatography (HPLC). Both monomers were completely hydrolyzed within 25 h by HSDEA. Photopolymerized composites were incubated with buffer or human saliva (pH 7.0 and 37 C) for 2, 8 and 16 days. The incubation solutions were analyzed using HPLC and mass spectrometry. Surface morphology characterization was carried out using scanning electron microscopy. Upon biodegradation, the Z250 composite yielded higher amounts of BisGMA and TEGDMA related products relative to the TPH composite. However, there were higher amounts of ethoxylated bis-phenol A released from the TPH material. In terms of total mass of products released, human saliva demonstrated a greater ability to degrade Z250. In summary, HSDEA has been shown to contain esterase activities that can readily catalyze the biodegradation of current commercial composite resins.

  19. Synthesis, Characterization and Glass - Reinforced Composites of Thiourea - Formaldehyde - Phenol Resin

    Directory of Open Access Journals (Sweden)

    Kanuprasad Dahyalal Patel

    2004-01-01

    Full Text Available N,N'-Dimethylol thiourea-formaldehyde (DMTUF resin having the methylol group (CH2OH has been prepared and characterized. The condensation of DMTUF resin with Phenol (P was carried out in the presence of alcoholic alkali catalyst at varying ratios of DMTUF: P, namely 1:1, 1:1.5 and 1:2. The resultant DMTUFP resin was characterized by elemental analysis, IR spectral studies, number average molecular weight ( M¯n estimated by non-aqueous conductometric titration, and thermo gravimetry. The curing study of DMTUFP resin with hexamethylene tetramine (HMTA was monitored by differential scanning calorimetry (DSC and kinetic parameters were evaluated. Glass-reinforced composites based on the DMTUFP-HMTA system have also been prepared and characterized.

  20. Synthesis, Characterization and Glass - Reinforced Composites of N,N'-Dimethylolthiourea – m-Aminophenol Resin

    Directory of Open Access Journals (Sweden)

    K. D. Patel

    2005-01-01

    Full Text Available N,N’-Dimethylolthiourea (DMTU resin having the methylol group ( –CH2 OH has been prepared and characterized. The condensation of DMTU resin with m-aminophenol was carried out in the presence of alcoholic alkali catalyst at varying ratios of DMTU: mAP, namely 1:1, 1:1.5 and 1:2. The resultant DMTUmAP resin was characterized by elemental analysis, IR spectral studies, number average molecular weight (M¯n estimated by non-aqueous conductometric titration, and thermogravimetry. The curing study of DMTUmAP resin with hexamethylenetetramine (HMTA was monitored by differential scanning calorimetry (DSC and kinetic parameters were evaluated. Glass-reinforced composites based on the DMTUmAP-HMTA system have also been prepared and characterized.

  1. Dental composite resins: measuring the polymerization shrinkage using optical fiber Bragg grating sensors

    Science.gov (United States)

    Ottevaere, H.; Tabak, M.; Chah, K.; Mégret, P.; Thienpont, H.

    2012-04-01

    Polymerization shrinkage of dental composite materials is recognized as one of the main reasons for the development of marginal leakage between a tooth and filling material. As an alternative to conventional measurement methods, we propose optical fiber Bragg grating (FBG) based sensors to perform real-time strain and shrinkage measurements during the curing process of dental resin cements. We introduce a fully automated set-up to measure the Bragg wavelength shift of the FBG strain sensors and to accurately monitor the linear strain and shrinkage of dental resins during curing. Three different dental resin materials were studied in this work: matrix-filled BisGMA-based resins, glass ionomers and organic modified ceramics.

  2. Effects of Hygrothermal Cycling on the Chemical, Thermal, and Mechanical Properties of 862/W Epoxy Resin

    Science.gov (United States)

    Miller, Sandi G.; Roberts, Gary D.; Copa, Christine C.; Bail, Justin L.; Kohlman, Lee W.; Binienda, Wieslaw K.

    2011-01-01

    The hygrothermal aging characteristics of an epoxy resin were characterized over 1 year, which included 908 temperature and humidity cycles. The epoxy resin quickly showed evidence of aging through color change and increased brittleness. The influence of aging on the material s glass transition temperature (Tg) was evaluated by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA). The Tg remained relatively constant throughout the year long cyclic aging profile. The chemical composition was monitored by Fourier Transform Infrared Spectroscopy (FTIR) where evidence of chemical aging and advancement of cure was noted. The tensile strength of the resin was tested as it aged. This property was severely affected by the aging process in the form of reduced ductility and embrittlement. Detailed chemical evaluation suggests many aging mechanisms are taking place during exposure to hygrothermal conditions. This paper details the influence of processes such as: advancement of cure, chemical degradation, and physical aging on the chemical and physical properties of the epoxy resin.

  3. Innovation in monitoring: The U.S. Geological Survey Sacramento–San Joaquin River Delta, California, flow-station network

    Science.gov (United States)

    Burau, Jon; Ruhl, Cathy; Work, Paul A.

    2016-01-29

    The U.S. Geological Survey (USGS) installed the first gage to measure the flow of water into California’s Sacramento–San Joaquin River Delta from the Sacramento River in the late 1800s. Today, a network of 35 hydro-acoustic meters measure flow throughout the delta. This region is a critical part of California’s freshwater supply and conveyance system. With the data provided by this flow-station network—sampled every 15 minutes and updated to the web every hour—state and federal water managers make daily decisions about how much freshwater can be pumped for human use, at which locations, and when. Fish and wildlife scientists, working with water managers, also use this information to protect fish species affected by pumping and loss of habitat. The data are also used to help determine the success or failure of efforts to restore ecosystem processes in what has been called the “most managed and highly altered” watershed in the country.

  4. MWCNTs/Resin Nanocomposites: Structural, Thermal, Mechanical and Dielectric Investigation

    Directory of Open Access Journals (Sweden)

    N. D. Alexopoulos

    2015-11-01

    Full Text Available Multi-wall carbon nanotubes (MWCNTs were manufactured, characterized and added to a typical aeronautical resin matrix at different concentrations as nano-reinforcement. The carbon content of produced MWCNTs was determined to be around 98.5% while they consisted of 13-20 wall-layers and their external diameter had an average size in between 20 and 50 nm. MWCNTs were dispersed in an epoxy resin system and tensile specimens for different MWCNTs concentrations were prepared in an open mould. Electrical wiring was attached to the specimens’ surface and surface electrical resistance change was in-situ monitored during monotonic tension till fracture. Performed tensile tests showed that the MWCNTs addition increased both modulus of elasticity and ultimate tensile strength on the nano-composites with a simultaneously dramatic ductility decrease. The MWCNTs addition enhanced the investigated resin matrix with monitoring ability; electrical resistance change of the investigated tensile tests was correlated in the elastic regime with axial nominal strain and the gauge factor of the different MWCNTs concentration specimens were calculated. It was found that lowest MWCNTs concentration gave the best results in terms of piezo-resistivity and simultaneously the least enhancement in the mechanical properties.

  5. Strontium-90 in ion-exchange resin used in the Australian FIEFS network

    International Nuclear Information System (INIS)

    Wise, K.N.

    1977-10-01

    In order to determine monthly strontium-90 fallout deposited at the eight Australian monitoring stations, account must be taken of the level of strontium-90 contamination of the ion-exchange resin as prepared for use in the FIEFS. This procedure has always been important in monitoring strontium-90 fallout deposit in Australia because the level of strontium-90 contamination of ion-exchange resin, supplied by manufacturers in the Northern Hemisphere, has remained of the same order of magnitude as the monthly fallout deposit in the Southern Hemisphere

  6. In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, Belle [Univ. of Tennessee, Knoxville, TN (United States); Hines, J. Wesley [Univ. of Tennessee, Knoxville, TN (United States); Damiano, Brian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mehta, Chaitanya [Univ. of Tennessee, Knoxville, TN (United States); Collins, Price [Univ. of Tennessee, Knoxville, TN (United States); Lish, Matthew [Univ. of Tennessee, Knoxville, TN (United States); Cady, Brian [Univ. of Tennessee, Knoxville, TN (United States); Lollar, Victor [Univ. of Tennessee, Knoxville, TN (United States); de Wet, Dane [Univ. of Tennessee, Knoxville, TN (United States); Bayram, Duygu [Univ. of Tennessee, Knoxville, TN (United States)

    2015-12-15

    The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on

  7. In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring

    International Nuclear Information System (INIS)

    Upadhyaya, Belle; Hines, J. Wesley; Damiano, Brian; Mehta, Chaitanya; Collins, Price; Lish, Matthew; Cady, Brian; Lollar, Victor; De Wet, Dane; Bayram, Duygu

    2015-01-01

    The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on

  8. Foam, Foam-resin composite and method of making a foam-resin composite

    Science.gov (United States)

    Cranston, John A. (Inventor); MacArthur, Doug E. (Inventor)

    1995-01-01

    This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.

  9. Modified Castor Oil as an Epoxy Resin Curing Agent

    Directory of Open Access Journals (Sweden)

    B. P. Patel

    2004-01-01

    Full Text Available A castor oil, an agricultural product, is an unsaturated material. Hence the castor oil is brominated by bromine liquid. The brominated castor oil (BCO was then reacted with excess of aliphatic diamines viz; ethylene diamine, 1,3-propane diamine and 1,6-hexane diamine. The resultant amino functionalized castor oil (ACO samples were then characterized by elemental analysis, IR spectral study and number of amino groups. All the three ACO samples were then employed for the curing of commercial Brominated epoxy resin. The curing of epoxy resin by ACO was monitored on differential scanning calorimeter (DSC and based on the DSC study their glass fibre reinforced composites (GRC were fabricated. The cured samples (i.e. unreinforced were also subjected to thermo gravimetric analysis (TGA. The chemical, mechanical and electrical properties of the glass fibre reinforced composites (GRC were also evaluated.

  10. Minimal intervention dentistry: part 6. Caries inhibition by resin infiltration.

    Science.gov (United States)

    Lasfargues, J J; Bonte, E; Guerrieri, A; Fezzani, L

    2013-01-01

    Resin infiltration has made possible an innovative way of treating initial carious lesions that fits perfectly with the concept of minimal intervention dentistry. Infiltration of carious lesions represents a new approach to the treatment of non-cavitated lesions of proximal and smooth surfaces of deciduous and permanent teeth. The major advantage of this method is that it is a non-invasive treatment, preserving tooth structure and that it can be achieved in a single visit. While this therapy can rightly be categorised as minimum intervention dentistry, clinical experience is limited and further controlled clinical trials are required to assess its long-term results. The inhibition of caries progression by resin infiltration should now be considered an alternative to invasive restorations, but involves early detection of lesions and does not allow for appropriate monitoring of the caries risk.

  11. Environmental Factors Affecting the Strength Characteristics of Modified Resin Mortars

    Science.gov (United States)

    Debska, Bernardeta; Licholai, Lech

    2017-12-01

    Resin concretes are composites in which a cement binder has been completely replaced by a synthetic resin. These materials are a good choice for the construction industry, especially in solutions requiring high strength, fast curing and durability. Polymer mortars are mainly used for the manufacture of industrial floors and prefabricated products such as tanks for aggressive chemicals, sewage pipes, or road and bridge drainage systems, as well as for the repair of damaged concrete structures. In all these applications, the strength and high chemical resistance of the applied material solutions are of key importance. It is particularly crucial to obtain information on how resin composites behave when exposed to aggressive agents over extended periods of time. It is also very important to use waste materials in order to obtain resin composites, as these activities are very well inscribed in the idea of environmental protection and meet the criteria of sustainable construction. The mortars described in this article meet the above principles. The article presents how the compressive strength of glycolyzate-modified epoxy mortars, obtained with the use of poly(ethylene terephthalate), changes after they are immersed in 10% sodium chloride solution. Sodium chloride solution was chosen due to the prospective applicability of the tested composites as repair materials used for e.g. bridges or overpasses that are exposed to this salt solution in wintertime. Changes in the properties of the composite samples were monitored over the period of one year. Statistical analysis of the test results was carried out with the use of Statistica programme. The module available in the mentioned program called Nonparametric Statistics - Comparing multiple independent samples made it possible to check the monitoring times during which the compressive strength values differed significantly. The obtained results allowed for determining the equation of the function approximating the course of

  12. Flow regime mapping: outcome, or pre-requisite of tracer tests? (from the standpoint of deep-georeservoir characterization, development, operation, and monitoring)

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2017-04-01

    Tracer tests in deep-subsurface flow usually yield fluid residence time distributions (RTD) for a sparse selection of fluid spiking and fluid sampling points. Such RTD can be explained more or less adequately assuming certain flow and transport boundary conditions, and a fractured-porous void-space structure in which advective-dispersive transport and possibly partitioning/reactions at interfaces take place. Yet RTD do not by themselves enable to tell 'where' a flow process is taking place. So to say, "to trace is not to track", and 'tracking' would require some complementary kind of mapping, imaging, or monitoring - additionally to the metering of tracer fluxes at the few accessible 'places' in the georeservoir (i. e., deep boreholes) at which fluids can be sampled. We do not feel the need for such 'tracking' capability, when tracer-based RTD are used to predict the thermal lifetime of, say, a geothermal well doublet. However, the ability to 'locate' flow and transport processes (in both space and time) may become critical when facing environmental impacts of deep-georeservoir operation, and liabilities associated with these. On the other hand, it can also be a primary task in reservoir diagnostics and engineering, for instance when facing the question of whether and where to re-frac (in unconventional reservoir development). The poster describes three paradigm settings where a complementary, non-fluid-borne mapping of flow regimes (or at least of flow regime contrasts) appears as a very sensible, if not indispensable counterpart to tracer-based RTD for predicting (or accounting for) deep-georeservoir behavior. These are illustrated with (a) inter-well tracings of geothermally exploited Malm aquifers beneath the Munich metropolitan area, in analogy to past work conducted by Seiler et al. (1989) in the Franconian Alb; (b) single-well spikings of petrothermal or aquifer-based EGS in the N-German sedimentary basin, with two major issues left unresolved by Ghergut et

  13. Real-Time Microscopic Monitoring of Flow, Voltage and Current in the Proton Exchange Membrane Water Electrolyzer.

    Science.gov (United States)

    Lee, Chi-Yuan; Li, Shih-Chun; Chen, Chia-Hung; Huang, Yen-Ting; Wang, Yu-Syuan

    2018-03-15

    Looking for alternative energy sources has been an inevitable trend since the oil crisis, and close attentioned has been paid to hydrogen energy. The proton exchange membrane (PEM) water electrolyzer is characterized by high energy efficiency, high yield, simple system and low operating temperature. The electrolyzer generates hydrogen from water free of any carbon sources (provided the electrons come from renewable sources such as solar and wind), so it is very clean and completely satisfies the environmental requirement. However, in long-term operation of the PEM water electrolyzer, the membrane material durability, catalyst corrosion and nonuniformity of local flow, voltage and current in the electrolyzer can influence the overall performance. It is difficult to measure the internal physical parameters of the PEM water electrolyzer, and the physical parameters are interrelated. Therefore, this study uses micro-electro-mechanical systems (MEMS) technology to develop a flexible integrated microsensor; internal multiple physical information is extracted to determine the optimal working parameters for the PEM water electrolyzer. The real operational data of local flow, voltage and current in the PEM water electrolyzer are measured simultaneously by the flexible integrated microsensor, so as to enhance the performance of the PEM water electrolyzer and to prolong the service life.

  14. Flow cytometric minimal residual disease monitoring in children with acute lymphoblastic leukemia treated by regimens with reduced intensity

    Directory of Open Access Journals (Sweden)

    A. M. Popov

    2015-01-01

    Full Text Available 191 consecutive unselected children with acute lymphoblastic leukemia aged from 1 to 16 years were enrolled in the study. Bone marrow samples were obtained at the time of initial diagnostics as well as at days 15 (n = 188, 36 (n = 191, and 85 (n = 187 of remission induction. Minimal residual disease (MRD was assessed by 6–10-color flow cytometry. Flow cytometry data at day 15 allowed distinguishing three patients groups with significantly different outcome (p ˂ 0.0001: 35.64 % patients with MRD < 0.1 % represented 5-year event-free survival (EFS of 100 %; 48.40 % cases with 0.1 % ≤ MRD< 10 % had EFS 84.6 ± 4.2 %; 15.96 % patients with very high MRD (≥ 10 % belonged to group with poor outcome (EFS 56.7 ± 9.0 %. At the end of remission induction (day 36 36 children (18.85 % with MRD higher than 0.1 % had significantly worse outcome compared to remaining ones (EFS 49.4 ± 9.0 and 93.5 ± 2.1 % respectively; p ˂ 0.0001. From a clinical standpoint it is relevant to evaluate both low-risk and high-risk criteria. Multivariate analysis showed that day 15 MRD data is better for low-risk patients definition while end-induction MRD is the strongest unfavorable prognostic factor.

  15. Synthesis of Hydrophobic, Crosslinkable Resins.

    Science.gov (United States)

    1984-12-01

    Bismaleimides have also been crosslinked with radical initiators to produce brittle networks [4].If a damine is added, chain extension and radical crosslinkinq...are produced during cure.The company also produced a similar phenylene based resin, with pendant nitrile groups which could be crosslinked without the...benzenes and tetra substituted cyclopentadienones [881. g. Preparation of poly 1,4 phenylene by nickel (0> catalysed electropolymerisation 1891. Cont’d

  16. Evaluation of adhesion of reline resins to the thermoplastic denture base resin for non-metal clasp denture.

    Science.gov (United States)

    Kim, Ji Hye; Choe, Han Cheol; Son, Mee Kyoung

    2014-01-01

    This study aimed to evaluate the tensile and transverse bond strength of chairside reline resins (Tokuyama Rebase II, Mild Rebaron LC) to a thermoplastic acrylic resin (Acrytone) used for non metal clasp denture. The results were compared with those of a conventional heat polymerized acrylic resin (Paladent 20) and a thermoplastic polyamide resin (Biotone). The failure sites were examined by scanning electron microscopy to evaluate the mode of failure. As results, the bond strength of reline resins to a thermoplastic acrylic resin was similar to the value of a conventional heat polymerized acrylic resin. However, thermoplastic polyamide resin showed the lowest value. The results of this study indicated that a thermoplastic acrylic resin for non metal clasps denture allows chairside reline and repair. It was also found that the light-polymerized reline resin had better bond strength than the autopolymerizing reline resin in relining for a conventional heat polymerized acrylic resin and a thermoplastic acrylic resin.

  17. A multisyringe flow-through sequential extraction system for on-line monitoring of orthophosphate in soils and sediments

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2007-01-01

    of extracted organic phosphorus and condensed inorganic phosphates within the time frame of the assay. The potential of the novel system for accommodation of the harmonized protocol from the Standards, Measurement and Testing (SMT) Program of the Commission of the European Communities for inorganic phosphorus.......5 mol l-1 HCl as extractants according to the Hietjles-Lijklema (HL) scheme for fractionation of phosphorus associated with different geological phases, and on-line processing of the extracts via the Molybdenum Blue (MB) reaction by exploiting multisyringe flow injection as the interface between...... of the operational times from days to hours, highly temporal resolution of the leaching process, and the capability for immediate decision for stopping or proceeding with the ongoing extraction. Very importantly, accurate determination of the various orthophosphate pools is ensured by minimization of the hydrolysis...

  18. Monitoring of cerebral blood flow autoregulation in adults undergoing sevoflurane anesthesia: a prospective cohort study of two age groups.

    Science.gov (United States)

    Goettel, Nicolai; Patet, Camille; Rossi, Ariane; Burkhart, Christoph S; Czosnyka, Marek; Strebel, Stephan P; Steiner, Luzius A

    2016-06-01

    Autoregulation of blood flow is a key feature of the human cerebral vascular system to assure adequate oxygenation and metabolism of the brain under changing physiological conditions. The impact of advanced age and anesthesia on cerebral autoregulation remains unclear. The primary objective of this study was to determine the effect of sevoflurane anesthesia on cerebral autoregulation in two different age groups. This is a follow-up analysis of data acquired in a prospective observational cohort study. One hundred thirty-three patients aged 18-40 and ≥65 years scheduled for major noncardiac surgery under general anesthesia were included. Cerebral autoregulation indices, limits, and ranges were compared in young and elderly patient groups. Forty-nine patients (37 %) aged 18-40 years and 84 patients (63 %) aged ≥65 years were included in the study. Age-adjusted minimum alveolar concentrations of sevoflurane were 0.89 ± 0.07 in young and 0.99 ± 0.14 in older subjects (P blood pressure range of 13.8 ± 9.8 mmHg in young and 10.2 ± 8.6 mmHg in older patients (P = 0.079). The lower limit of autoregulation was 66 ± 12 mmHg and 73 ± 14 mmHg in young and older patients, respectively (P = 0.075). The association between sevoflurane concentrations and autoregulatory capacity was similar in both age groups. Our data suggests that the autoregulatory plateau is shortened in both young and older patients under sevoflurane anesthesia with approximately 1 MAC. Lower and upper limits of cerebral blood flow autoregulation, as well as the autoregulatory range, are not influenced by the age of anesthetized patients. Trial registration ClinicalTrials.gov (NCT00512200).

  19. Changes in Wetting Hysteresis During Bioremediation: Changes in fluid flow behavior monitored with low-frequency seismic attenuation

    Science.gov (United States)

    Wempe, W.; Spetzler, H.; Kittleson, C.; Pursley, J.

    2003-12-01

    We observed significant reduction in wetting hysteresis with time while a diesel-contaminated quartz crystal was dipped in and out of an oil-reducing bacteria solution. This wetting hysteresis is significantly greater than the wetting hysteresis when the diesel-contaminated quartz crystal is dipped in and out of (1) water, (2) diesel and (3) the bacterial food solution that does not contain bacteria. The reduction in wetting hysteresis of the bacteria solution on the quartz surface results from a reduction in the advancing contact angle formed at the air-liquid-quartz contact with time; the receding contact angle remains the same with time. Our results suggest that the bacteria solution moves across the quartz surface with less resistance after bioremediation has begun. These results imply that bioremediation may influence fluid flow behavior with time. For many fluid-solid systems there is a difference between the contact angle while a contact line advances and recedes across a solid surface; this difference is known as wetting hysteresis. Changes in wetting hysteresis can occur from changes in surface tension or the surface topography. Low contact angle values indicate that the liquid spreads or wets well, while high values indicate poor wetting or non-wetting. Contact angles are estimated in the lab by measuring the weight of the meniscus formed at the air-liquid-quartz interface and by knowing the fluid surface tension. In the lab, we have been able to use low-frequency seismic attenuation data to detect changes in the wetting characteristics of glass plates and of Berea sandstone. The accepted seismic attenuation mechanism is related to the loss of seismic energy due to the hysteresis of meniscus movement (wetting hysteresis) when a pore containing two fluids is stressed at very low frequencies (measuring low-frequency seismic attenuation in the lab while flowing bacteria solution through Berea sandstone and we are testing this application in the field.

  20. Influence of flowable resins on the shear bond strength of orthodontic brackets.

    Science.gov (United States)

    Park, Soo-Byung; Son, Woo-Sung; Ko, Ching-Chang; García-Godoy, Franklin; Park, Mi-Gyoung; Kim, Hyung-Il; Kwon, Yong Hoon

    2009-11-01

    The present study tested the shear bond strength (SBS) of orthodontic brackets bonded to teeth using flowable resins. A total of 105 human teeth were divided into seven groups. The brackets in each group were bonded to the tooth substrates using a Transbond XT adhesive and six other different flowable resins, respectively. Each adhesive resin was light-cured using a quartz-tungsten-halogen (QTH) light for 40 seconds. The brackets were debonded in shear mode using a universal testing machine. The brackets bonded using Tetric Flow and Grandio Flow showed slightly greater SBS values (13.0+/-1.8 and 12.2+/-1.2 MPa, respectively) than the Transbond XT adhesive (12.1+/-1.2 MPa). However, the SBS values of Transbond XT, X-flow, Tetric Flow, Grandio Flow, and Filtek Z350 flow were not significantly different. As for Admira Flow and Aelite Flow, they scored significantly lower SBS values (7.0+/-2.1 and 9.2+/-1.3 MPa, respectively) than the other groups. On bracket failure mode, statistical analysis revealed a similar failure mode among all the seven test groups.

  1. [Adsorption and isolation of macroporous resin for three isoflavonoids from puerariae lobatae radix].

    Science.gov (United States)

    Cui, Yun-Hui; Wang, Zhi-Ping; Fan, Hua; Yang, Ke

    2013-04-01

    To study the adsorption function of macroporous resins for the separation and purification of three isoflavonoids (3'-hydroxypuerarin, puerarin, daidzin) in Puerariae Lobatae Radix. The contents of 3'-hydroxypuerarin, puerarin, daidzin were determined by HPLC. D101, AB-8, XDA-5, HP-20 and other five resins were systematically investigated for their adsorption capability, adsorption isothermal curve, adsorption and elution properties with static and dynamic experiments. Experimental results showed that macroporous resin XDA-5 owned optimum adsorption and elution parameters. Optimal conditions for adsorption and elution the three components were: per 1 mL solution contained Puerariae Lobatae Radix 0.5 - 0.8 g, flow rate 2BV/h, adsorbed 3'-hydroxypuerarin, puerarin and daidzin could be desorbed by alcohol at flow rate 1BV/h. The purity of 3'-hydroxypuerarin, puerarin and daidzin of the product obtained from Puerariae Lobatae Radix with optimum technology is 23.39%, 52.09% and 19.21%, respectively.

  2. Resin selection criteria for tough composite structures

    Science.gov (United States)

    Chamis, C. C.; Smith, G. T.

    1983-01-01

    Resin selection criteria are derived using a structured methodology consisting of an upward integrated mechanistic theory and its inverse (top-down structured theory). These criteria are expressed in a "criteria selection space" which are used to identify resin bulk properties for improved composite "toughness". The resin selection criteria correlate with a variety of experimental data including laminate strength, elevated temperature effects and impact resistance.

  3. Solidifying power station resins and sludges

    International Nuclear Information System (INIS)

    Willis, A.S.D.; Haigh, C.P.

    1984-01-01

    Radioactive ion exchange resins and sludges arise at nuclear power stations from various operations associated with effluent treatment and liquid waste management. As the result of an intensive development programme, the Central Electricity Generating Board (CEGB) has designed a process to convert power station resins and sludges into a shielded, packaged solid monolithic form suitable for final disposal. Research and development, the generic CEGB sludge/resin conditioning plant and the CEGB Active Waste Project are described. (U.K.)

  4. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  5. Porous Ceramic Spheres from Ion Exchange Resin

    Science.gov (United States)

    Dynys, Fred

    2005-01-01

    A commercial cation ion exchange resin, cross-linked polystyrene, has been successfully used as a template to fabricate 20 to 50 micron porous ceramic spheres. Ion exchange resins have dual template capabilities. Pore architecture of the ceramic spheres can be altered by changing the template pattern. Templating can be achieved by utilizing the internal porous structure or the external surface of the resin beads. Synthesis methods and chemical/physical characteristics of the ceramic spheres will be reported.

  6. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    OpenAIRE

    Furuse, Adilson Yoshio; Cunha, Leonardo Fernandes da; Benetti, Ana Raquel; Mondelli, José

    2007-01-01

    The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1) rinsing with water and drying; (G2) application of an adhesive system; (G3) rinsing and drying, abrasion wit...

  7. Novel silica-based ion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    Eichrom`s highly successful Diphonixo resin resembles a conventional ion exchange resin in its use of sulfonic acid ligands on a styrene- divinylbenzene matrix. Diphonix resin exhibits rapid exchange kinetics that allow economical operation of ion exchange systems. Unlike conventional resins, Diphonix resin contains chelating ligands that are diphosphonic acid groups that recognize and remove the targeted metals and reject the more common elements such as sodium, calcium and magnesium. This latter property makes Diphonix ideal for many industrial scale applications, including those involving waste treatment. For treatment of low-level, transuranic (TRU) and high- level radioactive wastes, Diphonix`s polystyrene backbone hinders its application due to radiolytic stability of the carbon-hydrogen bonds and lack of compatibility with expected vitrification schemes. Polystyrene-based Diphonix is approximately 60% carbon- hydrogen. In response to an identified need within the Department of Energy for a resin with the positive attributes of Diphonix that also exhibits greater radiolytic stability and final waste form compatibility, Eichrom has successfully developed a new, silica-based resin version of Diphonix. Target application for this new resin is for use in environmental restoration and waste management situations involving the processing of low-level, transuranic and high-level radioactive wastes. The resin can also be used for processing liquid mixed waste (waste that contains low level radioactivity and hazardous constituents) including mixed wastes contaminated with organic compounds. Silica-based Diphonix is only 10% carbon-hydrogen, with the bulk of the matrix silica.

  8. Microbiological study of water-softener resins.

    Science.gov (United States)

    Stamm, J M; Engelhard, W E; Parsons, J E

    1969-09-01

    Microbial identification using effluents backflushed from exhausted urban and rural tank resins and cleaned resins containing the sulfonated copolymer of styrene and divinylbenzene (SDB) were completed, along with microbial assessment of the concentrated stock salt brine. Forty-four different bacterial and fungal genera were identified. Extensive biochemical and animal virulence tests completed on one of the six bacterial salt brine isolates indicated a pathogenic staphylococcal strain. The retention of Staphylococcus aureus, a Flavobacterium sp, and Escherichia coli B bacteriophage was demonstrated both by using the nonexhausted sodium-regenerated resin and by using the same resin exchanged with different mono-, di-, and trivalent cations. Effluent counts completed after bacterial seepage through the resins indicated the Pb(++) exchanged resin removed 55% of the bacteria; Na(+), Fe(++), and Al(+++) removed 31 to 36% and Ca(++) and Cu(++) removed about 10 to 15%. Seventy per cent or more of the bacteriophage was removed by Fe(++), Cu(++), and Al(+++), whereas the Ca(++) and Na(++) cations removed 25 to 31%. Over a 77-day period, nonsterile tap water was passed through bacterial seeded and uninoculated SDB (Na) resin columns. Effluent and resin elution counts demonstrated the growth and survival of 2 different bacteria per column. Increased bacterial retention, survival, and multiplication occurred concomitantly with accumulation of organic and inorganic materials and the Ca(++) and Mg(++) cations from the tap water. Furthermore, microbial elution from resin particles taken from column depths of 1, 8, and 16 cm indicated a bacterial diminution with increasing depths.

  9. Stability of IRA-45 solid amine resin as a function of carbon dioxide absorption and steam desorption cycling

    Science.gov (United States)

    Wood, Peter C.; Wydeven, Theodore

    1987-01-01

    The removal of CO2 from the NASA Space Station's cabin atmosphere, which may be undertaken by a solid-amine water (steam)-desorbed system, is presently evaluated with a view to long-term amine resin stability and adsorption/desorption cycling by means of an automated laboratory flow-testing facility. While the CO2-adsorption capacity of the IRA-45 amine resin used gradually decreased over time, the rate of degradation significantly decreased after the first 10 cycles. Attention is given to the presence (and possible need for removal) of trimethylamine in the process air downstream of the resin bed.

  10. Heat-cured Acrylic Resin versus Light-activated Resin: A Patient ...

    African Journals Online (AJOL)

    Context: Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed ...

  11. Sewage Monitors

    Science.gov (United States)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  12. In-well time-of-travel approach to evaluate optimal purge duration during low-flow sampling of monitoring wells

    Science.gov (United States)

    Harte, Philip T.

    2017-01-01

    A common assumption with groundwater sampling is that low (time until inflow from the high hydraulic conductivity part of the screened formation can travel vertically in the well to the pump intake. Therefore, the length of the time needed for adequate purging prior to sample collection (called optimal purge duration) is controlled by the in-well, vertical travel times. A preliminary, simple analytical model was used to provide information on the relation between purge duration and capture of formation water for different gross levels of heterogeneity (contrast between low and high hydraulic conductivity layers). The model was then used to compare these time–volume relations to purge data (pumping rates and drawdown) collected at several representative monitoring wells from multiple sites. Results showed that computation of time-dependent capture of formation water (as opposed to capture of preexisting screen water), which were based on vertical travel times in the well, compares favorably with the time required to achieve field parameter stabilization. If field parameter stabilization is an indicator of arrival time of formation water, which has been postulated, then in-well, vertical flow may be an important factor at wells where low-flow sampling is the sample method of choice.

  13. FTIR analysis and the effects of alkyd/melamine resin ratio on the properties of the coatings

    OpenAIRE

    Cakić Suzana M.; Bošković Ljiljana B.

    2009-01-01

    Alkyd/melamine resin mixtures are mainly used in industrial baking enamels. The effects of the alkyd/butylated melamine resin ratio (from 90/10 to 50/50) and curing temperature (from 110 to 180°C) on the crosslinking and properties of the coating are presented in this paper. The curing reactions through functional groups of resins were monitored by FT-IR spectroscopy. The hardness, elasticity, degree of adherence and gloss were also determined. Optimal coating properties could be achieved wit...

  14. Industrial alkyd resins: characterization of pentaerythritol and phthalic acid esters using integrated mass spectrometry.

    Science.gov (United States)

    La Nasa, Jacopo; Degano, Ilaria; Modugno, Francesca; Colombini, Maria Perla

    2015-02-15

    Alkyd resins are synthetic polyesters used as paints and coatings. Current approaches for their analysis do not allow the characterization of pentaerythritol and phthalic acid esters, whose detection is interesting to fully characterize the materials, e.g. for forensic or cultural heritage applications. A combined analytical approach based on Gas Chromatography/Mass Spectrometry (GC/MS), High-Performance Liquid Chromatography (HPLC)/MS and flow injection analysis (FIA)/MS was adopted. GC/MS was used to characterize the fatty acid profile and the polybasic acids in extracts from industrial alkyd resins. HPLC/MS and FIA/MS were used for the characterization of the triglyceride profile of the oil used to manufacture the resin and for the identification of reaction products deriving from the synthesis process. The multi-analytical approach was applied on two different industrial alkyd resins produced from two different oils. The GC/MS analysis was successful in characterizing the fatty acid profile and the aromatic fraction of the resin. The HPLC/MS analysis allowed us to characterize the pentaerythritol and phthalic acid ester and the triglycerides residues from the synthesis process, by studying their high-resolution tandem mass spectra. The application of liquid chromatography coupled with high-resolution tandem mass spectrometry to the study of industrial alkyd resins allowed us to characterize for the first time the esters formed by the transesterification reactions involving pentaerythritol, phthalic acid and triglycerides. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Formaldehyde vapor produced from hexamethylenetetramine and pesticide: Simultaneous monitoring of formaldehyde and ozone in chamber experiments by flow-based hybrid micro-gas analyzer.

    Science.gov (United States)

    Yanaga, Akira; Hozumi, Naruto; Ohira, Shin-Ichi; Hasegawa, Asako; Toda, Kei

    2016-02-01

    Simultaneous analysis of HCHO and O3 was performed by the developed flow analysis system to prove that HCHO vapor is produced from solid pesticide in the presence of O3. HCHO is produced in many ways, including as primary emissions from fuel combustion and in secondary production from anthropogenic and biogenic volatile organic compounds by photochemical reactions. In this work, HCHO production from pesticides was investigated for the first time. Commonly pesticide contains surfactant such as hexamethylenetetramine (HMT), which is a heterocyclic compound formed from six molecules of HCHO and four molecules of NH3. HMT can react with gaseous oxidants such as ozone (O3) to produce HCHO. In the present study, a flow analysis system was developed for simultaneous analysis of HCHO and O3, and this system was used to determine if solid pesticides produced HCHO vapor in the presence of O3. HMT or the pesticide jimandaisen, which contains mancozeb as the active ingradient and HMT as a stabilizer was placed at the bottom of a 20-L stainless steel chamber. Air in the chamber was monitored using the developed flow system. Analyte gases were collected into an absorbing solution by a honeycomb-patterned microchannel scrubber that was previously developed for a micro gas analysis system (μGAS). Subsequently, indigotrisulfonate, a blue dye, was added to the absorbing solution to detect O3, which discolored the solution. HCHO was detected after mixing with the Hantzsch reaction reagent. Both gases could be detected at concentrations ranging from parts per billion by volume (ppbv) to 1000 ppbv with good linearity. Both HMT and jimandaisen emitted large amount of HCHO in the presence of O3. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Insect outbreaks produce distinctive carbon isotope signatures in defensive resins and fossiliferous ambers.

    Science.gov (United States)

    McKellar, Ryan C; Wolfe, Alexander P; Muehlenbachs, Karlis; Tappert, Ralf; Engel, Michael S; Cheng, Tao; Sánchez-Azofeifa, G Arturo

    2011-11-07

    Despite centuries of research addressing amber and its various inclusions, relatively little is known about the specific events having stimulated the production of geologically relevant volumes of plant resin, ultimately yielding amber deposits. Although numerous hypotheses have invoked the role of insects, to date these have proven difficult to test. Here, we use the current mountain pine beetle outbreak in western Canada as an analogy for the effects of infestation on the stable isotopic composition of carbon in resins. We show that infestation results in a rapid (approx. 1 year) (13)C enrichment of fresh lodgepole pine resins, in a pattern directly comparable with that observed in resins collected from uninfested trees subjected to water stress. Furthermore, resin isotopic values are shown to track both the progression of infestation and instances of recovery. These findings can be extended to fossil resins, including Miocene amber from the Dominican Republic and Late Cretaceous New Jersey amber, revealing similar carbon-isotopic patterns between visually clean ambers and those associated with the attack of wood-boring insects. Plant exudate δ(13)C values constitute a sensitive monitor of ecological stress in both modern and ancient forest ecosystems, and provide considerable insight concerning the genesis of amber in the geological record.

  17. Comparison of Cashew Nut Shell Liquid (CNS ) Resin with ...

    African Journals Online (AJOL)

    synthetic) resin. Compressive and tensile strength tests conducted proved that composites developed with cashew nut shell liquid (CNSL) resin were comparable to those developed with polyester resin. In the results, CNSL has an ultimate ...

  18. Flow cytometric monitoring of bacterioplankton phenotypic diversity predicts high population-specific feeding rates by invasive dreissenid mussels.

    Science.gov (United States)

    Props, Ruben; Schmidt, Marian L; Heyse, Jasmine; Vanderploeg, Henry A; Boon, Nico; Denef, Vincent J

    2018-02-01

    Species invasion is an important disturbance to ecosystems worldwide, yet knowledge about the impacts of invasive species on bacterial communities remains sparse. Using a novel approach, we simultaneously detected phenotypic and derived taxonomic change in a natural bacterioplankton community when subjected to feeding pressure by quagga mussels, a widespread aquatic invasive species. We detected a significant decrease in diversity within 1 h of feeding and a total diversity loss of 11.6 ± 4.1% after 3 h. This loss of microbial diversity was caused by the selective removal of high nucleic acid populations (29 ± 5% after 3 h). We were able to track the community diversity at high temporal resolution by calculating phenotypic diversity estimates from flow cytometry (FCM) data of minute amounts of sample. Through parallel FCM and 16S rRNA gene amplicon sequencing analysis of environments spanning a broad diversity range, we showed that the two approaches resulted in highly correlated diversity measures and captured the same seasonal and lake-specific patterns in community composition. Based on our results, we predict that selective feeding by invasive dreissenid mussels directly impacts the microbial component of the carbon cycle, as it may drive bacterioplankton communities toward less diverse and potentially less productive states. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  19. Stable and sensitive flow-through monitoring of phenol using a carbon nanotube based screen printed biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon, G; Guix, M; Ambrosi, A; Merkoci, A [Nanobioelectronics and Biosensors Group, Catalan Institute of Nanotechnology, Campus UAB, 08193 Bellaterra, Barcelona, Catalonia (Spain); Ramirez Silva, M T [Departamento de Quimica, Universidad Autonoma Metropolitana Iztapalapa, 09340 Mexico Distrito Federal (Mexico); Palomar Pardave, M E, E-mail: arben.merkoci.icn@uab.es [Departamento de Materiales, Universidad Autonoma Metropolitana, Azcapotzalco, 02200 Mexico Distrito Federal (Mexico)

    2010-06-18

    A stable and sensitive biosensor for phenol detection based on a screen printed electrode modified with tyrosinase, multiwall carbon nanotubes and glutaraldehyde is designed and applied in a flow injection analytical system. The proposed carbon nanotube matrix is easy to prepare and ensures a very good entrapment environment for the enzyme, being simpler and cheaper than other reported strategies. In addition, the proposed matrix allows for a very fast operation of the enzyme, that leads to a response time of 15 s. Several parameters such as the working potential, pH of the measuring solution, biosensor response time, detection limit, linear range of response and sensitivity are studied. The obtained detection limit for phenol was 0.14 x 10{sup -6} M. The biosensor keeps its activity during continuous FIA measurements at room temperature, showing a stable response (RSD 5%) within a two week working period at room temperature. The developed biosensor is being applied for phenol detection in seawater samples and seems to be a promising alternative for automatic control of seawater contamination. The developed detection system can be extended to other enzyme biosensors with interest for several other applications.

  20. Fracture Propagation, Fluid Flow, and Geomechanics of Water-Based Hydraulic Fracturing in Shale Gas Systems and Electromagnetic Geophysical Monitoring of Fluid Migration

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jihoon; Um, Evan; Moridis, George

    2014-12-01

    We investigate fracture propagation induced by hydraulic fracturing with water injection, using numerical simulation. For rigorous, full 3D modeling, we employ a numerical method that can model failure resulting from tensile and shear stresses, dynamic nonlinear permeability, leak-off in all directions, and thermo-poro-mechanical effects with the double porosity approach. Our numerical results indicate that fracture propagation is not the same as propagation of the water front, because fracturing is governed by geomechanics, whereas water saturation is determined by fluid flow. At early times, the water saturation front is almost identical to the fracture tip, suggesting that the fracture is mostly filled with injected water. However, at late times, advance of the water front is retarded compared to fracture propagation, yielding a significant gap between the water front and the fracture top, which is filled with reservoir gas. We also find considerable leak-off of water to the reservoir. The inconsistency between the fracture volume and the volume of injected water cannot properly calculate the fracture length, when it is estimated based on the simple assumption that the fracture is fully saturated with injected water. As an example of flow-geomechanical responses, we identify pressure fluctuation under constant water injection, because hydraulic fracturing is itself a set of many failure processes, in which pressure consistently drops when failure occurs, but fluctuation decreases as the fracture length grows. We also study application of electromagnetic (EM) geophysical methods, because these methods are highly sensitive to changes in porosity and pore-fluid properties due to water injection into gas reservoirs. Employing a 3D finite-element EM geophysical simulator, we evaluate the sensitivity of the crosswell EM method for monitoring fluid movements in shaly reservoirs. For this sensitivity evaluation, reservoir models are generated through the coupled flow

  1. Resin composite for sealing and its use in a solar cell. Fushiyo jushi soseibutsu oyobi sore wo mochiita taiyo denchi

    Energy Technology Data Exchange (ETDEWEB)

    Toma, H.; Mimura, T.; Takehara, N.

    1994-01-28

    This invention presents resin composites for sealing of a solar cell composed of a hardening resin and a thermoplastic resin which has a number average molecular weight larger than that of the hardening resin and is soluble in the hardening resin, and the invention affords a solar cell to endure a long-term stable operation and to give a good performance. The hardening resin includes unsaturated polyester resin, phenolic resin, alkyd resin, unsaturated acrylic resin, epoxy resin, polyurethane resin, melamine resin, diallyl phthalate resin, their oligomers and their modifications. The thermoplastic resin includes saturated polyester resin, phenolic resin, acrylic resin, styrene resin, epoxy resin, polyurethane resin, polyvinyl acetate resin, polyvinyl chloride resin, polyvinyl alcohol resin, polyacetal resin, their modifications and their copolymer resin. 2 figs., 3 tabs.

  2. Generic DART-MS platform for monitoring the on-demand continuous-flow production of pharmaceuticals: Advancing the quantitative protocol for caffeates in microfluidic biocatalysis.

    Science.gov (United States)

    Xu, Yan; Zhang, Dong-Yang; Meng, Xiang-Yun; Liu, Xi; Sheng, Sheng; Wu, Guo-Hua; Wang, Jun; Wu, Fu-An

    2017-04-15

    Today, continuous processing is regarded as an effective on-demand production technique of pharmaceuticals. Homemade microreactors packed with immobilized lipase under continuous-flow conditions were first applied to tailor the production of high-value caffeic acid phenethyl ester (CAPE) from methyl caffeate (MC) and 2-phenylethanol (PE) in cyclohexane via transesterification; however, this method is challenging due to the lack of a rapid platform for monitoring caffeates in microfluidic biocatalysis. The reactants were directly analyzed using Direct Analysis in Real Time Mass Spectrometry (DART-MS), and the corresponding ionization parameters were investigated. Special ions produced from MC (parent ion m/z 192.87 and product ion m/z 133.44) and CAPE (parent ion m/z 282.93 and product ion m/z 178.87) were determined using DART-MS 2 in the negative ion mode. The peak areas of the select reaction monitoring (SRM) signals were calculated to develop the standard curves for quantitative analyses of the concentration. Reasonable linear regression equations of MC and CAPE were obtained in the range of 3.125-50.000mg/L, with linear coefficients (R 2 ) of 0.9515 and 0.9973, limits of detection (LOD) of 0.005 and 0.003mg/L, limits of quantification (LOQ) of 0.02 and 0.01mg/L, and recovery ranges of 92.50-97.11% and 90.11-97.60%, respectively. The results using DART-MS 2 were in good agreement with those using conventional High-Performance Liquid Chromatography with a UV detector (HPLC-UV) and were successfully applied to monitor the kinetics constants and mass transfer coefficients in a continuous-flow packed bed microreactor. Thus, the DART-MS 2 method is an efficient tool for analyzing caffeates in microfluidic biocatalysis with limited sample preparation and short operating time. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Morse, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO4-). Perrhenate (ReO4-) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of

  4. Hygroscopic expansion kinetics of dental resin-composites.

    Science.gov (United States)

    Alrahlah, A; Silikas, N; Watts, D C

    2014-02-01

    To evaluate the extent and rate of hygroscopic expansion of resin composites at 37°C. Eight resin composites were examined: 1 micro-hybrid (Bright Light(®)), 5 nano-hybrids (Experimental Vertise™; Nanoceram-Bright(®); Tetric EvoCeram(®); Grandio(®) SO; Ceram X™ duo) and 2 flowables (X-tra base; Venus(®) Diamond Flow). Five disks (15 mm×2 mm) of each material were prepared. The mean change in specimen diameter was recorded by a custom-built non-contact laser micrometer. Specimens were initially measured dry and then at fixed time intervals, over 150 days, after storage in distilled water at 37±1°C. Data were re-expressed in volumetric terms and analysed by repeated measures ANOVA, one-way ANOVA and Tukey's post hoc test (α=0.05). The volumetric hygroscopic expansion ranged from 0.58 to 2.26 and can be considered in three bands. First, Experimental Vertise had the highest expansion (pGrandio So, Nanoceram-Bright and X-tra base, with no significant difference between them. For the size (2mm thickness) and shape of specimen measured, equilibrium was attained in all cases by 60 days. Within this set of resin-composites the equilibrium expansion varied by almost 400% of the lowest material. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Curing kinetics of alkyd/melamine resin mixtures

    OpenAIRE

    Jovičić Mirjana C.; Radičević Radmila Ž.

    2009-01-01

    Alkyd resins are the most popular and useful synthetic resins applied as the binder in protective coatings. Frequently they are not used alone but are modified with other synthetic resins in the manufacture of the coatings. An alkyd/melamine resin mixture is the usual composition for the preparation of coating called 'baking enamel' and it is cured through functional groups of resins at high temperatures. In this paper, curing kinetics of alkyd resins based on castor oil and dehydrated castor...

  6. Ultrasonic cure monitoring

    Science.gov (United States)

    Djordjevic, B. Boro

    1999-12-01

    Fiber reinforced organic matrix composites applied to large structures require inexpensive cure process control. This paper reports on work to develop simple ultrasonic NDE sensors suitable for manufacturing and in-field use. This sensor is designed around a short wave-guide ultrasonic probe that is embedded in composite for in-situ cure monitoring applications. The sensor measures changes in resin density and sound velocity during cure and can be quantitatively calibrated for determination of the final cure. The cure monitoring is based on acoustic impedance variance across a material interface and can be utilized over the full cure cycle change of the resin in the composite. Significant advantage of this method is the simplicity of the measurement, low cost of the wave-guide probe and the adaptability of the sensor configuration to various composite-processing environments

  7. Optimization of luteolin separation from pigeonpea [Cajanus cajan (L.) Millsp.] leaves by macroporous resins.

    Science.gov (United States)

    Fu, Yujie; Zu, Yuangang; Liu, Wei; Efferth, Thomas; Zhang, Naijing; Liu, Xiaona; Kong, Yu

    2006-12-29

    In the present study, the performance and separation characteristics of eight macroporous resins for the separation of luteolin (LU) from pigeonpea leaves extracts have been evaluated. The adsorption and desorption properties of LU on macroporous resins including AB-8, NKA-9, NKA-2, D3520, D101, H1020, H103 and AL-2 have been compared. AL-2 resin offers the best adsorption and desorption capacity for LU than other resins based on the research results, and its adsorption data at 25 degrees C fit best to the Freundlich isotherm. Dynamic adsorption and desorption experiments have been carried out with the column packed by AL-2 resin to optimize the separation process of LU from pigeonpea leaves extracts. The optimum parameters for adsorption were sample solution LU concentration 65.5 microg/ml, pH 5, processing volume 3 BV, flow rate 1.5BV/h, temperature 25 degrees C; for desorption were elution solvent ethanol-water (50:50, v/v) 2 BV and followed by ethanol-water (60:40, v/v) 2 BV, and flow rate 1BV/h. After treated with AL-2 resin, the LU content in the product was increased 19.8-fold from 0.129% to 2.55%, with a recovery yield of 78.54%. The results showed that AL-2 resin revealed a good ability to separate LU. Therefore, we conclude that results in this study may provide scientific references for the large-scale LU production from pigeonpea or other plants extracts.

  8. Preparative separation of vitexin and isovitexin from pigeonpea extracts with macroporous resins.

    Science.gov (United States)

    Fu, Yujie; Zu, Yuangang; Liu, Wei; Hou, Chunlian; Chen, Liyan; Li, Shuangming; Shi, Xiaoguang; Tong, Meihong

    2007-01-19

    Vitexin and isovitexin are a pair of isomeric compounds known as the major constituents in pigeonpea leaves and possess various pharmacological activities. In the present study, the preparative separation of vitexin and isovitexin with macroporous resins (Nankai Hecheng S & T, Tianjin, China) was studied. The performance and adsorption characteristics of eight macroporous resins including ADS-5, ADS-7, ADS-8, ADS-11, ADS-17, ADS-21, ADS-31 and ADS-F8 have been evaluated. The research results indicate that ADS-5 resin is most appropriate for the separation of vitexin and isovitexin. Langmuir and Freundlich isotherms were used to describe the interactions between solutes and resin at different temperatures, and the equilibrium experimental data were well fitted to the two isotherms. Column packed with ADS-5 resin was used to perform dynamic adsorption and desorption tests to optimize the separation process. The optimum parameters for adsorption were as follows: the concentration of vitexin and isovitexin in sample solution: 0.22 and 0.40mg/mL, respectively, processing volume: 3 BV, flow rate: 1mL/min, pH 4, temperature: 25 degrees C; for desorption: ethanol-water (40:60, v/v), 5 BV as an eluent, flow rate: 1mL/min. After one run treatment with ADS-5 resin, the contents of vitexin and isovitexin were increased 4.07-fold and 11.52-fold from 0.86%, 1.53% to 3.50% and 17.63%, the recovery yields were 65.03% and 73.99%, respectively. In conclusion, the preparative separation of vitexin and isovitexin can be easily and effectively achieved via adsorption and desorption on ADS-5 resin, and the method can be referenced for the separation of other flavone C-glucosides from herbal materials.

  9. Are resin composites suitable replacements for amalgam? A study of two-body wear.

    Science.gov (United States)

    Lazaridou, Dimitra; Belli, Renan; Petschelt, Anselm; Lohbauer, Ulrich

    2015-07-01

    Wear resistance is an important property of the dental materials, particularly for large restorations in the posterior regions and for the patients suffering from parafunctional activities. Additionally, the wear resistance of flowable composite resin materials is a clinical concern, although they are popular among dentists because of their easy handling. The aims of the present study were to evaluate the wear resistance of nine composite resins both condensable (G-aenial posterior, Venus, GrandioSO, Tetric EvoCeram, Ceram X duo, Filtek Supreme XTE) and new-generation flowable resin composites (G-aenial Universal Flo, GrandioSO Flow and GrandioSO Heavy Flow) and to compare these results with amalgam. Eight specimens of each material were subjected to two-body wear tests, using a chewing simulator. The wear region of each material was examined under profilometer, measuring the vertical loss (μm) and the volume loss (mm(3)) of the materials. Additionally, SEM analysis was performed to assess surfaces irregularities. The results showed significant difference of the vertical loss and the volume loss of the examined materials (p amalgam had the best wear resistance, two condensable resin composites (GrandioSO, Ceram X duo) and all flowable materials had no significant difference with amalgam. GrandioSO had the highest wear resistance and Filtek Supreme XTE the lowest wear resistance. The majority of resin composites had good wear resistance and similar to amalgam. Based on the in vitro measurements of two-body wear resistance, the new resin composites could replace amalgam for restorations placed in occlusal stress-bearing regions. New-generation flowable resin materials may also be used in occlusal contact restorations.

  10. Multiphase, multicomponent flow and transport models for Nuclear Test-Ban Treaty monitoring and nuclear waste disposal applications

    Science.gov (United States)

    Jordan, Amy

    Open challenges remain in using numerical models of subsurface flow and transport systems to make useful predictions related to nuclear waste storage and nonproliferation. The work presented here addresses the sensitivity of model results to unknown parameters, states, and processes, particularly uncertainties related to incorporating previously unrepresented processes (e.g., explosion-induced fracturing, hydrous mineral dehydration) into a subsurface flow and transport numerical simulator. The Finite Element Heat and Mass (FEHM) transfer code is used for all numerical models in this research. An experimental campaign intended to validate the predictive capability of numerical models that include the strongly coupled thermal, hydrological, and chemical processes in bedded salt is also presented. Underground nuclear explosions (UNEs) produce radionuclide gases that may seep to the surface over weeks to months. The estimated timing of gas arrival at the surface may be used to deploy personnel and equipment to the site of a suspected UNE, if allowed under the terms of the Comprehensive Nuclear Test-Ban Treaty. A model was developed using FEHM that considers barometrically pumped gas transport through a simplified fractured medium and was used to quantify the impact of uncertainties in hydrologic parameters (fracture aperture, matrix permeability, porosity, and saturation) and season of detonation on the timing of gas breakthrough. Numerical sensitivity analyses were performed for the case of a 1 kt UNE at a 400 m burial depth. Gas arrival time was found to be most affected by matrix permeability and fracture aperture. Gases having higher diffusivity were more sensitive to uncertainty in the rock properties. The effect of seasonality in the barometric pressure forcing was found to be important, with detonations in March the least likely to be detectable based on barometric data for Rainier Mesa, Nevada. Monte Carlo modeling was also used to predict the window of

  11. Seismic monitoring of hydraulic fracturing: techniques for determining fluid flow paths and state of stress away from a wellbore

    Energy Technology Data Exchange (ETDEWEB)

    Fehler, M.; House, L.; Kaieda, H.

    1986-01-01

    Hydraulic fracturing has gained in popularity in recent years as a way to determine the orientations and magnitudes of tectonic stresses. By augmenting conventional hydraulic fracturing measurements with detection and mapping of the microearthquakes induced by fracturing, we can supplement and idependently confirm information obtained from conventional analysis. Important information obtained from seismic monitoring includes: the state of stress of the rock, orientation and spacing of the major joint sets, and measurements of rock elastic parameters at locations distant from the wellbore. While conventional well logging operations can provide information about several of these parameters, the zone of interrogation is usually limited to the immediate proximity of the borehole. The seismic waveforms of the microearthquakes contain a wealth of information about the rock in regions that are otherwise inaccessible for study. By reliably locating the hypocenters of many microearthquakes, we have inferred the joint patterns in the rock. We observed that microearthquake locations do not define a simple, thin, planar distribution, that the fault plane solutions are consistent with shear slippage, and that spectral analysis indicates that the source dimensions and slip along the faults are small. Hence we believe that the microearthquakes result from slip along preexisting joints, and not from tensile extension at the tip of the fracture. Orientations of the principal stresses can be estimated by using fault plane solutions of the larger microearthquakes. By using a joint earthquake location scheme, and/or calibrations with downhole detonators, rock velocities and heterogeneities thereof can be investigated in rock volumes that are far enough from the borehole to be representative of intrincis rock properties.

  12. Monitoring and modeling very large, rapid infiltration using geophysics during the 2014 Lower Colorado River pulse flow experiment

    Science.gov (United States)

    Kennedy, J.; Macy, J. P.; Callegary, J. B.; Lopez, J. R.

    2014-12-01

    In March and April 2014, an unprecedented experiment released over 100x106 cubic meters (81,000 acre-feet) of water from Morelos Dam into the normally-dry lower Colorado River below Yuma, Arizona, USA. More than half of the water released from Morelos Dam infiltrated within the limitrophe reach, a 32-km stretch between the Northern U.S.-Mexico International Boundary and the Southern International Boundary, a distance of just 32 river-kilometers. To characterize the spatial and temporal extent of infiltration, scientists from the US Geological Survey, Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California, and Universidad Autónoma de Baja California carried out several geophysical surveys. Frequency-domain electromagnetic transects throughout the limitrophe reach showed that the subsurface comprised exclusively sandy material, with little finer-grained material to impede or otherwise influence infiltration. Direct current resistivity clearly imaged the rising water table near the stream channel. Both techniques provide valuable parameterization and calibration information for a surface-water/groundwater interaction model currently in development. Time-lapse gravity data were collected at 25 stations to expand the monitoring well network and provide storage-coefficient information for the groundwater model. Despite difficult field conditions, precise measurements of large gravity changes showed that changes in groundwater storage in the upper reach of the study area, where groundwater levels were highest, were constrained to the near vicinity of the river channel. Downstream near the Southern International Boundary, however, groundwater storage increased substantially over a large area, expanding into the regional aquifer that supplies irrigation water to surrounding agriculture.

  13. Adsorbability Enhancement of Macroporous Resin by Dielectric Barrier Discharge Plasma Treatment to Phenol in Water

    Directory of Open Access Journals (Sweden)

    Shoufeng Tang

    2016-01-01

    Full Text Available In order to enhance the adsorption efficiency and economize the use of macroporous resin, we have treated it with the dielectric barrier discharge (DBD plasma to improve its adsorbing capacity for phenol. The effects of operation conditions, for instance, applied voltage, treated time, and air flow rate on resin, were investigated by adsorption kinetics and isotherms. Results showed that the adsorption data were in good agreement with the pseudo-second-order and Freundlich equation. Experimental results showed that the modified resin was 156.5 mg/g and 39.2% higher than the untreated sample, when the modified conditions were conducted for discharge voltage 20 kV, treatment time 45 min, and air flow rate 1.2 L/min. The resin was characterized by FTIR and nitrogen adsorption isotherms before and after the DBD processes. It was found that the reason for the enhancement of resin adsorbability was attributed to the DBD plasma changing the surface physical and chemical structure.

  14. Input to Resin Column Structural Analysis if Autocatalytic Resin Reaction Occurs in HB-Line Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Hallman, D.F.

    2001-07-10

    Solutions of plutonium in nitric acid are purified and concentrated using anion resin prior to precipitation. There have been instances of resin column explosions caused by autocatalytic reactions of anion resins in nitric acid within the DOE complex

  15. Intracranial pressure monitoring (image)

    Science.gov (United States)

    Intracranial pressure monitoring is performed by inserting a catheter into the head with a sensing device to monitor the pressure around the brain. An increase in intracranial pressure can cause a decrease in blood flow to ...

  16. Gold Loading on Ion Exchange Resins in Non-Ammoniacal Resin-Solution Systems

    Directory of Open Access Journals (Sweden)

    Abrar Muslim

    2010-12-01

    Full Text Available The loading of gold using strong base anion exchange resin in non-ammoniac resin-solution (NARS systems has been studied. The loading of gold onto ion exchange resins is affected by polythionate concentration, and trithionate can be used as the baseline in the system. The results also show that resin capacity on gold loading increases due to the increase in the equilibrium thiosulfate concentration in the NARS system. Gold loading performances show the need of optimization the equilibrium concentrations of thiosulfate in the NARS system. Keywords: equilibrium, gold loading, resin capacity, thiosulfate, trithionate

  17. Polyimide Resins Resist Extreme Temperatures

    Science.gov (United States)

    2009-01-01

    Spacecraft and aerospace engines share a common threat: high temperature. The temperatures experienced during atmospheric reentry can reach over 2,000 F, and the temperatures in rocket engines can reach well over 5,000 F. To combat the high temperatures in aerospace applications, Dr. Ruth Pater of Langley Research Center developed RP-46, a polyimide resin capable of withstanding the most brutal temperatures. The composite material can push the service temperature to the limits of organic materials. Designed as an environmentally friendly alternative to other high-temperature resins, the RP-46 polyimide resin system was awarded a 1992 "R&D 100" award, named a "2001 NASA Technology of the Year," and later, due to its success as a spinoff technology, "2004 NASA Commercial Invention of the Year." The technology s commercial success also led to its winning the Langley s "Paul F. Holloway Technology Transfer Award" as well as "Richard T. Whitcom Aerospace Technology Transfer Award" both for 2004. RP-46 is relatively inexpensive and it can be readily processed for use as an adhesive, composite, resin molding, coating, foam, or film. Its composite materials can be used in temperatures ranging from minus 150 F to 2,300 F. No other organic materials are known to be capable of such wide range and extreme high-temperature applications. In addition to answering the call for environmentally conscious high-temperature materials, RP-46 provides a slew of additional advantages: It is extremely lightweight (less than half the weight of aluminum), chemical and moisture resistant, strong, and flexible. Pater also developed a similar technology, RP-50, using many of the same methods she used with RP-46, and very similar in composition to RP-46 in terms of its thermal capacity and chemical construction, but it has different applications, as this material is a coating as opposed to a buildable composite. A NASA license for use of this material outside of the Space Agency as well as

  18. The solidification of spent resin

    International Nuclear Information System (INIS)

    Shiao, S. J.; Tsai, C. M.; Shyu, Y. H.

    1991-01-01

    A quasi-steady apparatus was applied to measure the thermal conductivity of solids ranging in size for 0.3 to 200 L, and temperature distributions in the solids were recorded during the curing, and theoretical equation for conduction in a cylindrical form with uniform energy generation was established to define the thermal state of reaction. The heat of reaction calculated from the theoretical equation with experimental values for the maximum temperature and thermal conductivity agrees very well with the data reported. The relationships among heat of reaction and amount of curing agent, retardant, loading of spent resin, and water were established

  19. Post-irradiation crosslinking of partially cured unsaturated polyester resin

    International Nuclear Information System (INIS)

    Jurkin, Tanja; Pucic, Irina

    2006-01-01

    The post-irradiation crosslinking of unsaturated polyester (UP) resin samples irradiated to different doses was monitored during the 15-days period. The post-reaction sensitivity of three experimental techniques was evaluated. Significant changes were detected by extraction analysis that also included determination of the free styrene content. The most substantial changes were detected by differential scanning calorimetry, even up to 5 days after the irradiation. The sensitivity and reproducibility of FTIR was the lowest. The first two techniques detected the influence of particular reaction periods, at which the radiation crosslinking was terminated, on the post-reaction

  20. Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

    Science.gov (United States)

    Ehrlich, Joshua W.; Tate, LaNetra C.; Cox, Sarah B.; Taylor, Brian J.; Wright, M. Clara; Faughnan, Patrick D.; Batterson, Lawrence M.; Caraccio, Anne J.; Sampson, Jeffery W.

    2013-01-01

    Engineers today are presented with the opportunity to design and build the next generation of space vehicles out of the lightest, strongest, and most durable materials available. Composites offer excellent structural characteristics and outstanding reliability in many forms that will be utilized in future aerospace applications including the Commercial Crew and Cargo Program and the Orion space capsule. NASA's Composites for Exploration (CoEx) project researches the various methods of manufacturing composite materials of different fiber characteristics while using proven infusion methods of different resin compositions. Development and testing on these different material combinations will provide engineers the opportunity to produce optimal material compounds for multidisciplinary applications. Through the CoEx project, engineers pursue the opportunity to research and develop repair patch procedures for damaged spacecraft. Working in conjunction with Raptor Resins Inc., NASA engineers are utilizing high flow liquid infusion molding practices to manufacture high-temperature composite parts comprised of intermediate modulus 7 (IM7) carbon fiber material. IM7 is a continuous, high-tensile strength composite with outstanding structural qualities such as high shear strength, tensile strength and modulus as well as excellent corrosion, creep, and fatigue resistance. IM7 carbon fiber, combined with existing thermoset and thermoplastic resin systems, can provide improvements in material strength reinforcement and deformation-resistant properties for high-temperature applications. Void analysis of the different layups of the IM7 material discovered the largest total void composition within the [ +45 , 90 , 90 , -45 ] composite panel. Tensile and compressional testing proved the highest mechanical strength was found in the [0 4] layup. This paper further investigates the infusion procedure of a low-cost/high-performance BMI resin into an IM7 carbon fiber material and the

  1. Comparison of Cashew Nut Shell Liquid (CNS Resin with Polyester Resin in Composite Development

    Directory of Open Access Journals (Sweden)

    C. C. Ugoamadi

    2013-12-01

    Full Text Available Natural resins can compete effectively with the synthetic ones in composite development. In this research, cashew nuts were picked and processed for the extraction of the resin content. The resin (natural resin so obtained was mixed with cobalt amine (accelerator, methyl ethyl ketone peroxide (catalyst to develop two sets of composite specimens – specimens without fibres and specimens reinforced with glass fibres. This method of sample specimen development was repeated with polyester (synthetic resin. Compressive and tensile strength tests conducted proved that composites developed with cashew nut shell liquid (CNSL resin were comparable to those developed with polyester resin. In the results, CNSL has an ultimate compressive strength of 55MPa compared to that of polyester resin with an ultimate strength of 68MPa. The result of tensile strength proved cashew nut shell liquid resin (with ultimate strength of 44MPa to be better than polyester resin with 39MPa as ultimate tensile strength. This means that natural resins could be a better substitute for the synthetic ones when the required quantities of fibers (reinforcements and fillers are used in the fibre-reinforced plastic composite developments.

  2. Shear bond strength of different surface treatments in bulk fill, microhybrid, and nanoparticle repair resins

    Directory of Open Access Journals (Sweden)

    de Jesus Tavarez RR

    2017-07-01

    Full Text Available Rudys Rodolfo de Jesus Tavarez,1 Lauber Jose dos Santos Almeida Júnior,2 Tayanne Christine Gomes Guará,1 Izabella Santos Ribeiro,1 Etevaldo Matos Maia Filho,1 Leily Macedo Firoozmand2 1Department of Restorative Dentistry, Ceuma University (CEUMA, 2Department of Dentistry I, University Federal of Maranhão (UFMA, São Luís, Maranhão, Brazil Objectives: The purpose of this study was to evaluate the influence of surface treatment and different types of composite resin on the microshear bond strength of repairs. Materials and methods: Seventy-two specimens (n=72 were prepared using a nanoparticle resin and stored in artificial saliva at 37 ± 1°C for 24 h. After this period, the specimens (n=24 were restored with microhybrid resin P60 (3M ESPE, nanoparticle resin Filtek Z350 (3M ESPE, and Bulk Fill Surefil SDR Flow (Dentsply composite resins. Previously, the surfaces of the samples were treated, forming the following subgroups (n=12: (A conditioned with 37% phosphoric acid for 30 s, and (B abrasioned with a diamond tip for 3 s and conditioned with 37% phosphoric acid. In all groups, before insertion of the composite resin, the adhesive system Adper Single Bond 2 was actively applied and photopolymerized for 20 s. Results: The microshear test was executed to assess bond strength. Kruskal–Wallis (p<0.05 and Mann–Whitney statistical tests showed significant statistical difference considering that the bulk-fill resin turned out to have a lower bond strength than the conventional nanoparticle and microhybrid composites. With regard to the technique, the roughening with diamond bur followed by the application of phosphoric acid exhibited values higher than the exclusive use of acid. Conclusion: The microshear bond strength of the composite resin repairs varies in accordance with the type of composite resin utilized, and roughening the surface increased the bond strength of these materials. Keywords: bulk-fill resins, composite resins, dental

  3. New system applying image processor to automatically separate cation exchange resin and anion exchange resin for condensate demineralizer

    International Nuclear Information System (INIS)

    Adachi, Tsuneyasu; Nagao, Nobuaki; Yoshimori, Yasuhide; Inoue, Takashi; Yoda, Shuji

    2014-01-01

    In PWR plant, condensate demineralizer is equipped to remove corrosive ion in condensate water. Mixed bed packing cation exchange resin (CER) and anion exchange resin (AER) is generally applied, and these are regenerated after separation to each layer periodically. Since the AER particle is slightly lighter than the CER particle, the AER layer is brought up onto the CER layer by feeding water upward from the bottom of column (backwashing). The separation performance is affected by flow rate and temperature of water for backwashing, so normally operators set the proper condition parameters regarding separation manually every time for regeneration. The authors have developed the new separation system applying CCD camera and image processor. The system is comprised of CCD camera, LED lamp, image processor, controller, flow control valves and background color panel. Blue color of the panel, which is corresponding to the complementary color against both ivory color of AER and brown color of CER, is key to secure the system precision. At first the color image of the CER via the CCD camera is digitized and memorized by the image processor. The color of CER in the field of vision of the camera is scanned by the image processor, and the position where the maximum difference of digitized color index is indicated is judged as the interface. The detected interface is able to make the accordance with the set point by adjusting the flow rate of backwashing. By adopting the blue background panel, it is also possible to draw the AER out of the column since detecting the interface of the CER clearly. The system has provided the reduction of instability factor concerning separation of resin during regeneration process. The system has been adopted in two PWR plants in Japan, it has been demonstrating its stable and precise performance. (author)

  4. Hydraulic Permeability of Resorcinol-Formaldehyde Ion-Exchange Resin - Effects of Oxygen Uptake and Radiation

    International Nuclear Information System (INIS)

    Taylor, Paul Allen

    2009-01-01

    An ion-exchange process, using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the U.S. Department of Energy's (DOE) Hanford site in Washington State. The RF resin is also being evaluated for use in the proposed Small Column Ion Exchange (SCIX) system, which is an alternative treatment option at DOE's Savannah River Site (SRS)in South Carolina. Testing at ORNL will determine the impact of radiation exposure and oxygen uptake by the RF resin on the hydraulic permeability of the resin. Samples of the resin will be removed periodically to measure physical properties (bead size and compressibility) and cesium capacity. The proposed full-scale treatment system at Hanford, the Waste Treatment Plant (WTP), will use an ion-exchange column containing nominally 680 gal of resin, which will treat 30 gpm of waste solution. The ion-exchange column is designed for a typical pressure drop of 6 psig, with a maximum of 9.7 psig. The lab-scale column is 3-in. clear PVC pipe and is prototypic of the proposed Hanford column. The fluid velocity in the lab-scale test will be much higher than for the full-scale column, in order to generate the maximum pressure drop expected in that column (9.7 psig). The frictional drag from this high velocity will produce similar forces on the resin in the lab-scale column as would be expected at the bottom of the full-scale column. The chemical changes in the resin caused by radiation exposure and oxygen uptake are expected to cause physical changes in the resin that could reduce the bed porosity and reduce the hydraulic permeability of the resin bed. These changes will be monitored by measuring the pressure drop through the lab-scale column and by measuring the physical properties of samples of the resin. The test loop with the lab-scale column is currently being fabricated, and operation will start by late May. Testing will be completed by the

  5. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments.

    Science.gov (United States)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel; Mondelli, José

    2007-12-01

    The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1) rinsing with water and drying; (G2) application of an adhesive system; (G3) rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4) rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (presin increments.

  6. resin as polymer-supported synthesis support

    Indian Academy of Sciences (India)

    Administrator

    dichloro-5,6-dicyano- benzoqunone ... ports used most widely in SPOS are Merrifield resin .... (2 × 10 mL). The resin was dried at 50°C for one hour to give white beads. IR (KBr): 3108, 3312 cm–1. 1H-NMR (500 MHz, CDCl3): δ 7⋅13 (br s, PS), 7⋅01.

  7. [Delayed asthma bronchiale due to epoxy resin].

    Science.gov (United States)

    Authried, Georg; Al-Asadi, Haifaa; Møller, Ulla; Sherson, David Lee

    2013-10-28

    Epoxy resin is a low molecular weight agent, which can cause both acute and delayed allergic reactions. However, it is known causing skin reactions with direct or airborne contact. Rarely it can cause airway reactions like asthma bronchiale. We describe a case of a windmill worker who developed delayed asthma bronchiale due to airborne contact with epoxy resin.

  8. Epoxidation of linseed oil-Alkyd resins

    International Nuclear Information System (INIS)

    Motawie, A.M.; Ismail, E.A.; Mazroua, A.M.; Abd EI Aziem, M.S.; Ramadan, A.M.

    2004-01-01

    Three types of different linseed oil-alkyd resin ( Alk (I), Alk (II), and Alk (III) ) were prepared with the calculated amounts of mono glycerides and adipic acid (1:1, 1:2, and 2:1 Eq.Wt) respectively via monoglyceride method. The obtained alkyd resins were epoxidized via reaction with the calculated quantities of peracetic acid, which was prepared by the reaction of acetic anhydride with H 2 O 2 . Epoxidation occurred with the ratio (1: 1, 1 :3, and 1:6 Eq. Wt) of alkyd to peracetic acid. The effect of reaction time on the epoxy group content was measured during the epoxidation process. The prepared alkyd resins were analyzed by IR and H 1 NMR. The metal coated film properties of epoxidized alkyd resins were compared with those of unmodified alkyd resins. It was observed that the coating films of epoxidized alkyd resins have better in drying properties, hardness, adhesion, impact and flexibility than those of un epoxidized alkyd resins. The flammability properties of the paper coated films for the prepared brominated epoxidized alkyd resins were found to be fire retardant

  9. Facile synthesis of hypercrosslinked resins via chloromethylation ...

    Indian Academy of Sciences (India)

    A sort of non-polystyrene type hypercrosslinked resin was firstly synthesized through chloromethylation of simple aryl molecules (benzene, toluene, naphthalene, diphenyl), succedent continuous Friedel–Crafts alkylation polymerization and post-crosslinking reaction. The chemical and porous structures of these novel resins ...

  10. Life cycle strain monitoring in glass fibre reinforced polymer laminates using embedded fibre Bragg grating sensors from manufacturing to failure

    DEFF Research Database (Denmark)

    Nielsen, Michael Wenani; Schmidt, Jacob Wittrup; Høgh, Jacob Herold

    2013-01-01

    A holistic approach to strain monitoring in fibre-reinforced polymer composites is presented using embedded fibre Bragg grating sensors. Internal strains are monitored in unidirectional E-glass/epoxy laminate beams during vacuum infusion, curing, post-curing and subsequent loading in flexure unti...... Bragg gratings within the loading regime. This study confirms the effectiveness of composite life cycle strain monitoring for developing consistent manufacturing processes....... failure. The internal process-induced strain development is investigated through use of different cure schedules and tool/part interactions. The fibre Bragg grating sensors successfully monitor resin flow front progression during infusion, and strain development during curing, representative...... of the different cure temperatures and tool/part interfaces used. Substantial internal process-induced strains develop in the transverse fibre direction, which should be taken into consideration when designing fibre-reinforced polymer laminates. Flexure tests indicate no significant difference in the mechanical...

  11. Physical Properties of Synthetic Resin Materials

    Science.gov (United States)

    Fishbein, Meyer

    1939-01-01

    A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

  12. Electrodialytic decontamination of spent ion exchange resins

    International Nuclear Information System (INIS)

    Nott, B.R.

    1982-01-01

    Development of a novel electrodialytic decontamination process for the selective removal of radioactive Cs from spent ion exchange resins containing large amounts of Li is described. The process involves passage of a dc electric current through a bed of the spent ion exchange resin in a specially designed electrodialytic cell. The radiocesium so removed from a volume of the spent resin is concentrated onto a much smaller volume of a Cs selective sorbent to achieve a significant radioactive waste volume reduction. Technical feasibility of the electrodialytic resin decontamination process has been demonstrated on a bench scale with a batch of simulated spent ion exchange resin and using potassium cobalt ferrocyanide as the Cs selective sorbent. A volume reduction factor between 10 and 17 has been estimated. The process appears to be economically attractive. Improvements in process economics can be expected from optimization of the process. Other possible applications of the EDRD process have been identified

  13. Embedding of reactor wastes in plastic resins

    International Nuclear Information System (INIS)

    1979-01-01

    STEAG Kernenergie GmbH is so far the only firm commercially to condition radioactive bead ion exchange resins by embedding in polystyrene resins. The objective of the work reported here was to study and develop methods for immobilization of other reactor wastes in plastic resins. Comparison studies on high quality cement however showed favourable results for cement with respect to process safety and economy. For this reason STEAG interrupted its work in the field of resin embedding after about one year. The work carried out during this period is surveyed in this report, which includes a comprehensive literature study on reactor wastes and their solidification in plastic resins as well as on regulations with regard to radioactive waste disposal in the member states of the European Communities

  14. Disinfection of denture base acrylic resin.

    Science.gov (United States)

    Lin, J J; Cameron, S M; Runyan, D A; Craft, D W

    1999-02-01

    During repair or adjustments of acrylic resin removable complete and partial dentures, particles of the acrylic resin from the interior of the prosthesis may expose dental personnel to microbial health hazards if the prosthesis has not been thoroughly disinfected. This study investigates the efficacy of a commercially prepared microbial disinfectant (Alcide) on the external and internal surfaces of acrylic resins. Four groups of acrylic resin were incubated in an experimental model to simulate the oral environment over time. Specimens were treated in 2 groups, disinfected and not disinfected, and then further grouped by breaking and not breaking. Analysis was performed with microbial colony counts, SEM, and statistical analyses. Viable microorganisms still remain on the internal and external surfaces of treated resins. Chlorine dioxide reduces, but does not eliminate, viable microorganisms on these dental prostheses.

  15. Solidification of ion exchange resin wastes

    International Nuclear Information System (INIS)

    1982-08-01

    Solidification media investigated included portland type I, portland type III and high alumina cements, a proprietary gypsum-based polymer modified cement, and a vinyl ester-styrene thermosetting plastic. Samples formulated with hydraulic cement were analyzed to investigate the effects of resin type, resin loading, waste-to-cement ratio, and water-to-cement ratio. The solidification of cation resin wastes with portland cement was characterized by excessive swelling and cracking of waste forms, both after curing and during immersion testing. Mixed bed resin waste formulations were limited by their cation component. Additives to improve the mechanical properties of portland cement-ion exchange resin waste forms were evaluated. High alumina cement formulations dislayed a resistance to deterioration of mechanical integrity during immersion testing, thus providing a significant advantage over portland cements for the solidification of resin wastes. Properties of cement-ion exchange resin waste forms were examined. An experiment was conducted to study the leachability of 137 Cs, 85 Sr, and 60 Co from resins modified in portland type III and high alumina cements. The cumulative 137 Cs fraction release was at least an order of magnitude greater than that of either 85 Sr or 60 Co. Release rates of 137 Cs in high alumina cement were greater than those in portland III cement by a factor of two.Compressive strength and leach testing were conducted for resin wastes solidified with polymer-modified gypsum based cement. 137 Cs, 85 Sr, and 60 Co fraction releases were about one, two and three orders of magnitude higher, respectively, than in equivalent portland type III cement formulations. As much as 28.6 wt % dry ion exchange resin was successfully solidified using vinyl ester-styrene compared with a maximum of 25 wt % in both portland and gypsum-based cement

  16. Evaluation of a novel methacrylate-based Protein A resin for the purification of immunoglobulins and Fc-fusion proteins.

    Science.gov (United States)

    McCaw, Tyler R; Koepf, Edward K; Conley, Lynn

    2014-01-01

    Protein A affinity chromatography is a central part of most commercial monoclonal antibody and Fc-fusion protein purification processes. In the last couple years an increasing number of new Protein A technologies have emerged. One of these new Protein A technologies consists of a novel, alkaline-tolerant, Protein A ligand coupled to a macroporous polymethacrylate base matrix that has been optimized for immunoglobulin (Ig) G capture. The resin is interesting from a technology perspective because the particle size and pore distribution of the base beads are reported to have been optimized for high IgG binding and fast mass transfer, while the Protein A ligand has been engineered for enhanced alkaline tolerance. This resin was subjected to a number of technical studies including evaluating dynamic and static binding capacities, alkaline stability, Protein A leachate propensity, impurity clearance, and pressure-flow behavior. The results demonstrated similar static binding capacities as those achieved with industry standard agarose Protein A resins, but marginally lower dynamic binding capacities. Removal of impurities from the process stream, particularly host cell proteins, was molecule dependent, but in most instances matched the performance of the agarose resins. This resin was stable in 0.1 M NaOH for at least 100 h with little loss in binding capacity, with Protein A ligand leakage levels comparable to values for the agarose resins. Pressure-flow experiments in lab-scale chromatography columns demonstrated minimal resin compression at typical manufacturing flow rates. Prediction of resin compression in manufacturing scale columns did not suggest any pressure limitations upon scale up. © 2014 American Institute of Chemical Engineers.

  17. On-line continuous monitoring of glucose or lactate by ultraslow microdialysis combined with a flow-through nanoliter biosensor based on poly(m-phenylenediamine) ultra-thin polymer membrane as enzyme electrode

    NARCIS (Netherlands)

    Rhemrev-Boom, MM; Jonker, MA; Venema, K; Jobst, G; Tiessen, R; Korf, J

    2001-01-01

    A miniaturised flow-through biosensor with a cell volume of only a few nanoliters was developed in our laboratory. The biosensor can be directly coupled to a microdialysis or ultrafiltration probe. Sampling and continuous on-line monitoring can thus be carried out at submicroliter levels and as a

  18. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  19. Comparison of retention rates of fissure sealants using two flowable restorative materials and a conventional resin sealant: two-year follow-up.

    Science.gov (United States)

    Oba, Aylin Akbay; Sönmez, Işıl Şaroğlu; Ercan, Ertuğrul; Dülgergil, Türksel

    2012-01-01

    The purpose of this clinical study was to compare the retention rates of two flowable restorative systems (Admira Flow and Grandio Flow) with that of a conventional resin-based sealant (Fissurit F). The study was planned as a clinical trial with a split-mouth design. A total of 122 sealants (38 Admira Flow, 41 Grandio Flow, 43 Fissurit F) were randomly applied to completely erupted permanent molars in 35 patients aged 9-20 years and followed up for 24 months. Data were analyzed using Pearson's χ(2) and multiple comparison tests. At the end of the follow-up period, Fissurit F had higher retention rates (81.0%) than both Admira Flow (60.5%) and Grandio Flow (57.1%), with p 0.05). The two flowable composite resin materials used as fissure sealant were less retentive than the conventional resin sealant. Copyright © 2011 S. Karger AG, Basel.

  20. Simulation and Validation of Injection-Compression Filling Stage of Liquid Moulding with Fast Curing Resins

    Science.gov (United States)

    Martin, Ffion A.; Warrior, Nicholas A.; Simacek, Pavel; Advani, Suresh; Hughes, Adrian; Darlington, Roger; Senan, Eissa

    2018-03-01

    Very short manufacture cycle times are required if continuous carbon fibre and epoxy composite components are to be economically viable solutions for high volume composite production for the automotive industry. Here, a manufacturing process variant of resin transfer moulding (RTM), targets a reduction of in-mould manufacture time by reducing the time to inject and cure components. The process involves two stages; resin injection followed by compression. A flow simulation methodology using an RTM solver for the process has been developed. This paper compares the simulation prediction to experiments performed using industrial equipment. The issues encountered during the manufacturing are included in the simulation and their sensitivity to the process is explored.

  1. Feasibility study of the water Cherenkov detector as a D-T fusion power monitor in the system using neutron activation of flowing water. First experimental phase

    International Nuclear Information System (INIS)

    Verzilov, Yury M.; Ochiai, Kentaro; Nishitani, Takeo

    2003-09-01

    The technique of monitoring D-T neutrons using water flow is based on the reaction of the 16 O(n, p) 16 N. In order to significantly improve the D-T neutron monitoring system in the ITER reactor in comparison with the system that uses a γ-ray scintillation detector, a new approach was proposed. The basic idea of this approach is to utilize the Cherenkov light, produced by energetic β-particles from 16 N in water near the first wall of the fusion reactor, and then deliver the light by the optical fiber to the remote light detector. The proof of the principle experiment is divided into two phases. The main idea of the first experimental phase is to examine Cherenkov light measurements using a remotely located water and light detector. During the second phase the water radiator will be placed next to the neutron source, then the Cherenkov light will be transferred by an optical fiber to the remotely located light detector. For the purpose of the first experimental phase, a water Cherenkov detector was installed in the shielded measurement room. A closed water loop, with circulating water, was used to transport 16 N from the D-T source to the Cherenkov detector. The experiment was carried out at FNS/JAERI, with the accelerator set to a direct current mode, the source neutron yield around 2 x 10 11 n/s, and the water flowage approximately 2 m/s. The registered Cherenkov signal was identified as the light produced by β-particles from 16 N using the time decay and the energy spectra data. According to the present study, the water Cherenkov detector is very effective for measurements of the 16 N activity, due to high counting efficiency, absence of the scintillation detector and simplicity of the method. (author)

  2. Study by dynamic light scattering of an o/w emulsion of an epoxi resin dispersed in water by means of a triblock copolymer of type PEO-PPO-PEO

    International Nuclear Information System (INIS)

    Uscanga, E. H.; Rio, J. M. del; Avendano-Gomez, J. R.

    2009-01-01

    The curing epoxy resins are widely used in various fields of chemical industry, such as adhesives, automotive, coatings, etc. The process operation consisting of flow and mixing of epoxy resins become difficult due to their high viscosity. One solution is to dissolve the epoxy resin in volatile organic solvents (VOS) such as toluene, xylene or benzene. However, the use of VOS is not only expensive but harmful to the environment. (Author)

  3. Evaluation of Resin-Resin Interface in Direct Composite Restoration Repair

    Science.gov (United States)

    Stoleriu, S.; Andrian, S.; Pancu, G.; Nica, I.; Iovan, G.

    2017-06-01

    The aim of this study was to evaluate the resin-resin interface when a universal bonding agent was used in two different strategies in direct restoration repair. Two composite resins (a micro-filled hybrid and a nano-filled hybrid) as old restorations that have to be repair, a universal bonding agent and a micro-filled hybrid composite resin (different then that aged) as new material for repair were chosen for the study. Non-aged samples were used as control and aged samples were used as study groups. The universal bonding agent was applied in etch-and-rinse and in self-etch strategies. The interface between old and new composite resins was evaluated by SEM and the microleakage was assessed by scoring the dye penetration. Very good adaptation of the two different composite resins placed in direct contact in non-aged samples was recorded. No gaps or defects were visible and strong resin-resin contact was observed. After aging, enlargement of resin-resin junction were observed in most of the samples and a increased dye penetration was recorded irrespective of the strategy (etch-and-rinse or self-etch) used for bonding agent application.

  4. Effect of water chemistry on flow accelerated corrosion rate of carbon steel measured by on-line corrosion-monitoring system

    International Nuclear Information System (INIS)

    Fujiwara, K.; Domae, M.; Yoneda, K.; Inada, F.

    2010-01-01

    Flow Accelerated Corrosion (FAC) of carbon steel is one of the most important subjects in coolant systems of power plants. FAC is influenced by material, flow condition, temperature, and water chemistry. Iron and chromium solubility should be the most effective factor to determine the effect of water chemistry on the FAC. It is very important to evaluate the correlation between the solubility and the FAC rate of the carbon steel. In the present study, the effects of pH and Cr concentration of material on the FAC rate of carbon steel were evaluated by using high temperature loop equipment with on-line corrosion-monitoring system. Effect of dissolved oxygen concentration at pH 7 was also evaluated. The experimental FAC rates were compared with the calculation result, which was obtained from a FAC model developed previously by the authors' group. The tube specimens made of STPT 480 carbon steel were used for the FAC tests. The Cr concentration of STPT 480 was specially adjusted to 0.001 and 0.08 %. The inner diameters of the tubes were 1.6, 2.4, and 3.2 mm. The solutions were fed to the specimens with the flow rate of 1.5 l/min. The temperature of the solution at the specimen was controlled at 140 o C. Test solutions were demineralized water or NH 3 solutions of pH 8.0, 9.2, and 10.0. The increase in pH more than 9 decreased the FAC rates of both 0.001 and 0.08 % Cr specimens at 140 o C. Increase of the Cr concentration of the material decreased the FAC rate in the solution of pH 7.0, 8.0, 9.2, and 10.0. The FAC model reproduced well dependence of the experimental FAC behavior on water chemistry. It was confirmed that effect of pH and Cr concentration of material on the FAC rate were closely related to the solubility and diffusion of iron and chromium. (author)

  5. Bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Hamanaka, Ippei; Shimizu, Hiroshi; Takahashi, Yutaka

    2017-01-01

    This study evaluated the shear bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins. Four kinds of injection-molded thermoplastic resins (two polyamides, a polyethylene terephthalate copolymer and a polycarbonate) and PMMA, as a control, were tested. The eight types of surface treatment: ((1) no treatment, (2) air abrasion, (3) dichloromethane, (4) ethyl acetate, (5) 4-META/MMA-TBB resin, (6) air abrasion and 4-META/MMA-TBB resin, (7) tribochemical silica coating, and (8) tribochemical silica coating and 4-META/MMA-TBB resin) were applied to each specimen. The chairside autopolymerizing reline resins were bonded to disks of the injection-molded thermoplastic denture base resins. All of the specimens were immersed in water for 4 months and then thermocycled for 10,000 cycles in water between 5 and 55°C. The shear bond strengths were determined. The shear bond strengths of the two polyamides treated using air abrasion, dichloromethane and ethyl acetate and no treatment were exceedingly low. The greatest bond strength was recorded for the polyethylene terephthalate copolymer specimens treated with tribochemical silica coating and 4-META/MMA-TBB resin (22.5MPa). The bond strengths of the other injection-molded thermoplastic denture base resins increased using 4-META/MMA-TBB resin. Tribochemical silica coating and 4-META/MMA-TBB resin were the most effective surface treatments among all denture base resins tested. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Comparative study between the radiopacity levels of high viscosity and of flowable composite resins, using digital imaging.

    Science.gov (United States)

    Arita, Emiko S; Silveira, Gilson P; Cortes, Arthur R; Brucoli, Henrique C

    2012-01-01

    The development of countless types and trends of high viscosite and flowable composite resins, with different physical and chemical properties applicable to their broad use in dental clinics calls for further studies regarding their radiopacity level. The aim of this study was to evaluate the radiopacity levels of high viscosity and the flowable composite resins, using digital imaging. 96 composite resin discs 5 mm in diameter and 3 mm thick were radiographed and analyzed. The image acquisition system used was the Digora® Phosphor Storage System and the images were analyzed with the Digora software for Windows. The exposure conditions were: 70 kVp, 8 mA, and 0.2 s. The focal distance was 40 cm. The image densities were obtained with the pixel values of the materials in the digital image. Most of the high viscosity composite resins presented higher radiopacity levels than the flowable composite resins, with statistically significant differences between the trends and groups analyzed (P composite resins, Tetric®Ceram presented the highest radiopacity levels and Glacier® presented the lowest. Among the flowable composite resins, Tetric®Flow presented the highest radiopacity levels and Wave® presented the lowest.

  7. A novel malonamide grafted polystyrene-divinyl benzene resin for extraction, pre-concentration and separation of actinides.

    Science.gov (United States)

    Ansari, S A; Mohapatra, P K; Manchanda, V K

    2009-01-30

    A new chelating polymeric extraction chromatographic resin was prepared by chemical anchoring of N,N'-dimethyl-N,N'-dibutyl malonamide (DMDBMA) with chloromethylated Merrifield resin((R)). The grafted resin exhibited stronger binding for hexavalent and tetravalent actinides such as U(VI), Th(IV) and Pu(IV) over trivalent actinides, viz. Am(III) and Pu(III). Batch studies on solid phase extraction performed over a wide range of acid solution (0.01-6M HNO(3)) revealed that ternary mixer of uranium, americium and plutonium or thorium, americium and plutonium could be separated from each other at 1M HNO(3). Desorption of U(VI), Pu(IV) and Am(III) from the loaded resin was efficiently carried out using 0.1M alpha-HIBA, 0.25M oxalic acid and 0.01M EDTA, respectively. Quantitative pre-concentration of actinide ions such as Th(IV) and U(VI) was possible from 3M HNO(3) solution. The practical utility of the grafted resin was evaluated by uranium sorption measurements in several successive cycles. The sorption efficiency of the resin with respect to uranyl ion remained unchanged even after 30 days of continuous use. The surface morphology of the resin was monitored with the help of scanning electron microscopy (SEM) technique.

  8. 40 CFR 63.505 - Parameter monitoring levels and excursions.

    Science.gov (United States)

    2010-07-01

    ... National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.505... identification of each batch emission episode and the information required to determine parameter monitoring...

  9. Mineralogy of fossil resins in Northern Eurasia

    Science.gov (United States)

    Bogdasarov, M. A.

    2007-12-01

    The investigation is focused on identification and origin of fossil resins from the Cretaceous, Tertiary, and Quaternary sediments of Northern Eurasia on the basis of detailed study of their physical and chemical characteristics: morphology; size; mass; density; optical, mechanical, and thermal properties; chemical composition; etc. The composition of amorphous organic minerals with polymeric structure, fossil resins included, is studied with IR spectrometry, the EPR method, derivatography at low heating rates, XRD, chemical analysis, emission spectrometry, etc. The results of investigation summarized for the Baltic-Dnieper, North Siberian, and Far East amber-bearing provinces show some similarity of fossil resins in combination with specific features inherent to each province. Resins from the Baltic-Dnieper province should be termed as amber (succinite). Their variety is the most characteristic of Northern and Eastern Europe. Amber-like fossil resins from the North Siberian and Far East provinces are irrelevant to succinite. They usually occur as brittle resins, namely, retinite and gedanite, without jewelry value. Viscous fossil resin rumänite with an expected high economic value occurs in the Far East, on the shore of Sakhalin Island.

  10. Investigation of fossil resins and amber

    Directory of Open Access Journals (Sweden)

    E.Yu. Makarova

    2017-05-01

    Full Text Available Fossil resins and amber are a product of lithogenesis of resinous substances of higher plants – resinite. These components of plants, like other lipoid ingredients (suberins, coutines, sporinins, natural rubbers are resistant to microbial action, so they are well preserved in bacterial processing of organic matter in the stages of sedimento- and diagenesis, and are well diagnosed in microscopic studies. They occur in a rather wide age range of sedimentary rocks. The amber of the Baltic region of the Eocene age is most fully studied. The article presents the results of a study of the collection of fossil resins and amber from various regions of the world. Samples were studied microscopically; carbon isotope analysis, infrared spectroscopy (IR spectroscopy were performed. The most informative analysis of high-molecular polymeric compounds is IR spectroscopy. It was found that in the analyzed samples of fossil resins of different ages, aromatic compounds are not observed, most of which are first volatilized in fossilization processes. The possibility of influencing the group composition of amber and amber-like resins for sedimentation, diagenesis and catagenesis is discussed. The IR spectra of fossil and modern resin conifers are compared. Using the IR spectroscopy method, an attempt was made to identify the botanical origin of fossil resins.

  11. Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos

    Energy Technology Data Exchange (ETDEWEB)

    Huerta Espino, Mario; Martinez Flores, Marco Antonio; Martinez Villafane, Alberto; Porcayo Calderon, Jesus; Gomez Guzman, Roberto; Reyes Cervantes, Fernando [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    The direct measurement of metal temperatures during operation in superheater, reheater, and water wall tubes in zones exposed to high thermal flows is of great interest for the operation and analysis of the correct functioning of a steam generator. The operation temperature measurement of these zones differs very much of the monitored temperature in headers in the dead chamber, since the temperature measured in this zone is the steam temperature that does not reflect the one detected in the gas zone. For this reason, the thermocouples implant in gas zones will detect the real metal temperature and the incidence that some operation variables might have on it (Martinez et al., (1990). [Espanol] La medicion directa de temperaturas de metal durante operacion en tubos de sobrecalentador, recalentador y pared de agua en zonas expuestas a altos flujos termicos es de gran interes para la operacion y analisis del buen funcionamiento de un generador de vapor. La medicion de la temperatura de operacion de estas zonas, difiere mucho de la temperatura monitoreada en cabezales en zona de camara muerta, ya que la temperatura registrada en esta zona es la de vapor que no es un reflejo de la detectada en zona de gases. Por esta razon, la implantacion de termopares en zona de gases detectara la temperatura de metal real y la incidencia que algunas variables de operacion tengan sobre esta (Martinez et al., 1990).

  12. Melamine-modified urea formaldehyde resin for bonding particleboards

    Science.gov (United States)

    Chung-Yun Hse; Feng Fu; Hui Pan

    2008-01-01

    For the development of a cost-effective melamine-modified urea formaldehyde resin (MUF), the study evaluated the effects of reaction pH and melamine content on resin properties and bond performance of the MUF resin adhesive systems. Eight resins, each with three replicates, were prepared in a factorial experiment that included two formulation variables: two reaction...

  13. The effects of fouled anion resin on condensate polishing plant performance at Dungeness B power station

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Chris [British Energy, Barnwood, Gloucester (United Kingdom)

    2008-10-15

    The return to power, after an outage, at Dungeness B Power Station was delayed because of problems in achieving an in-specification feedwater acid conductivity. Dungeness B has a full flow cation/mixed bed condensate polishing plant (CPP). Investigations showed that the acid conductivity was produced by carbon dioxide and organic impurities both by-passing the CPP and slipping through it. Resin analysis showed that the anion resin had severely impaired sulfate removal kinetics. The paper covers the work done to try and identify the nature and source of the organics and their effect on the anion resin. One significant finding was that the carbonate removal kinetics were as impaired as those for sulfate removal; this had not been previously experienced in the CPP at any British Energy plant. (orig.)

  14. Monitoring measurements by difference flow method during the year 2006, drillholes OL-KR1, KR2, KR4, KR7, KR8, KR10, KR14, KR22, KR22B, KR27 and KR28

    International Nuclear Information System (INIS)

    Vaeisaesvaara, J.; Poellaenen, J.; Sokolnicki, M.

    2008-04-01

    The Posiva Flow Log/Difference Flow Method can be used for a relatively fast determination of water conductivity and hydraulic head in fractures/fractured zones in cored drillholes. In this method, a flow meter with a flow guide is used. This report presents the principles and results of the measurements carried out in drillholes OL-KR1, -KR2, -KR4, -KR7, -KR8, -KR10, -KR14, -KR22, -KR22B, -KR27 and -KR28 at the Olkiluoto investigation site during the year 2006. These measurements are a part of the Olkiluoto monitoring programme. Two different section lengths (2 m and 0.5 m) were used in the flow logging measurements. The flow into the drillhole or from the drillhole into the bedrock was measured within the section. Measurements were carried out both in natural conditions and when the drillhole was pumped. The transmissivity (T) and hydraulic head (h) of zones were calculated and are presented in the results. The measurement device also includes a sensor for single-point resistance (SPR) measurements. SPR was always measured in connection with flow measurements. SPR is measured when the tool is moving. The electric conductivity of fracture-specific water (EC) was measured in selected fractures in some of the drillholes. The fractures were chosen on the basis of the measured flow from the fracture to the drillhole. In addition to this some previously selected fractures were measured. The EC of the drillhole water was measured separately. (orig.)

  15. Resin-based luting agents and color stability of bonded ceramic veneers.

    Science.gov (United States)

    Almeida, Júlia R; Schmitt, Gabriela U; Kaizer, Marina R; Boscato, Noéli; Moraes, Rafael R

    2015-08-01

    The type of resin-based luting agent might influence the color stability of ceramic veneers. The purpose of this study was to investigate the effects of resin-based agents and aging on the color stability of ceramic veneers bonded to enamel. Ceramic disks were cemented to bovine enamel disks with 4 resin-based luting agents (n=10): dual-polymerizing cement (RelyX ARC), light-polymerizing cement (RelyX Veneer), flowable composite resin (Filtek Z350 Flow), or composite resin preheated for 30 minutes at 60°C (Filtek Z350 XT). CIE L*, a*, and b* color coordinates were measured 24 hours after cementation (baseline) with a color spectrophotometer and reevaluated after 10,000 and 20,000 thermal cycles. Color variation was calculated by using CIELab (ΔE*(ab)) and CIEDE2000 (ΔE00) methods. Then 95% confidence intervals were calculated for color variation means between baseline and 10,000 thermal cycles and between 10,000 and 20,000 thermal cycles. The 95% confidence intervals were also calculated for the means of individual color coordinates (L*, a*, and b*). The dual-polymerizing cement had the highest color variation among all luting agents. No significant differences were found in color variation among the light-polymerizing materials. All agents showed ΔE*(ab)>3.46 and ΔE00>2.25 after 20,000 thermal cycles. Variations in L*, a*, and b* coordinates were material dependent. The dual-polymerizing agent was yellowish and reddish after aging. The dual-polymerizing cement had higher color variation than the light-polymerized materials when used for bonding ceramic veneers to enamel. Flowable and preheated composite resins had similar color stability to that of light-polymerizing resin-based cement. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Resin intrusion into the primary circuit of NPP Jaslovske Bohunice V-1

    International Nuclear Information System (INIS)

    Grezdo, O.; Mraz, V.

    2005-01-01

    During the refueling at the first unit of Bohunice NPP in 2005 a lot of sediment was found on the upper storage rack. This sediment was identification as a filter resin. Resin was found in most of the fuel assemblies, pipes and tanks of the primary circuit and his auxiliary systems. Resin producer and WANO network was contacted in order to get information about similar events. Management of Bohunice NPP made a decision that primary circuit, fuel assemblies and auxiliary systems have to be cleaned. Subsequent cleaning extended outage by 31 days. This paper summarizes causes, existing consequences and corrective actions. Accent was put on the hydraulic characteristics of the primary circuit measurement, power distribution core monitoring and the primary circuit water quality verification (Authors)

  17. Properties of a nanodielectric cryogenic resin

    Energy Technology Data Exchange (ETDEWEB)

    Polyzos, Georgios [ORNL; Tuncer, Enis [ORNL; Sauers, Isidor [ORNL; More, Karren Leslie [ORNL

    2010-01-01

    Physical properties of a nanodielectric composed of in situ synthesized titanium dioxide (TiO{sub 2}) nanoparticles ({le} 5 nm in diameter) and a cryogenic resin are reported. The dielectric losses were reduced by a factor of 2 in the nanocomposite, indicating that the presence of small TiO{sub 2} nanoparticles restricted the mobility of the polymer chains. Dielectric breakdown data of the nanodielectric was distributed over a narrower range than that of the unfilled resin. The nanodielectric had 1.56 times higher 1% breakdown probability than the resin, yielding 0.64 times thinner insulation thickness for the same voltage level, which is beneficial in high voltage engineering.

  18. SEM and elemental analysis of composite resins

    International Nuclear Information System (INIS)

    Hosoda, H.; Yamada, T.; Inokoshi, S.

    1990-01-01

    Twenty-four chemically cured, 21 light-cured anterior, three light-cured anterior/posterior, and 18 light-cured posterior composite resins were examined using scanning electron microscopy, and the elemental composition of their filler particles was analyzed with an energy dispersive electron probe microanalyzer. According to the results obtained, the composite resins were divided into five groups (traditional, microfilled type, submicrofilled type, hybrid type, and semihybrid), with two additional hypothetical categories (microfilled and hybrid). Characteristics of each type were described with clinical indications for selective guidance of respective composite resins for clinical use

  19. In-depth disinfection of acrylic resins.

    Science.gov (United States)

    Chau, V B; Saunders, T R; Pimsler, M; Elfring, D R

    1995-09-01

    This study demonstrated that bacteria penetrate three kinds of dental acrylic resin after a short time period. Samples of acrylic resin were contaminated with a variety of bacteria and were then placed in three different disinfecting solutions as directed by the manufacturers. After the specific dilution and immersion time, cultures were made from the resin samples. The only effective disinfectant was a 0.525% solution of sodium hypochlorite at a 10-minute immersion. It disinfected not only the surfaces but also the bacteria that penetrated the surfaces to a depth of 3 mm.

  20. Immobilisation of ion exchange resins in cement

    International Nuclear Information System (INIS)

    Howard, C.G.; Jolliffe, C.B.; Lee, D.J.

    1990-09-01

    The removal of activity from spent decontaminating solutions eg LOMI can be achieved using organic ion exchange resins. These resins can be successfully immobilised in cement based matrices. The optimum cement system contained 10% ordinary Portland cement 84% gg blast furnace slag, 6% microsilica with a water cement ratio of 0.5 and a dry resin loading of 36% with respect to total weight. This formulation was successfully scaled up to 200 litres giving a product with acceptable compressive strength, dimensional stability and elastic modulus. Storage of samples under water appears to have no detrimental effects on the product's properties. (author)

  1. Cobalt Ions Improve the Strength of Epoxy Resins

    Science.gov (United States)

    Stoakley, D. M.; St. Clair, A. K.

    1986-01-01

    Technique developed for improving mechanical strength of epoxy resins by adding cobalt ions in form of tris(acetylacetonato)cobalt (III) complex. Solid cast disks prepared from cobalt ion-containing epoxy resins tested for flexural strength and stiffness. Incorporation of cobalt ions into epoxies increased flexural strength of resins by 10 to 95 percent. Suitable resins for this technique include any liquid or solid TGMDA resins. Improved epoxy formulation proves useful as composite matrix resin, adhesive, or casting resin for applications on commercial and advanced aircraft.

  2. FTIR analysis and the effects of alkyd/melamine resin ratio on the properties of the coatings

    Directory of Open Access Journals (Sweden)

    Cakić Suzana M.

    2009-01-01

    Full Text Available Alkyd/melamine resin mixtures are mainly used in industrial baking enamels. The effects of the alkyd/butylated melamine resin ratio (from 90/10 to 50/50 and curing temperature (from 110 to 180°C on the crosslinking and properties of the coating are presented in this paper. The curing reactions through functional groups of resins were monitored by FT-IR spectroscopy. The hardness, elasticity, degree of adherence and gloss were also determined. Optimal coating properties could be achieved with an alkyd/melamine resin ratio of 80/20, a curing temperature of 150°C and a curing time of 20 min.

  3. Colour spectrum and resin-type determine the concentration and composition of Polycyclic Aromatic Hydrocarbons (PAHs) in plastic pellets.

    Science.gov (United States)

    Fisner, Mara; Majer, Alessandra; Taniguchi, Satie; Bícego, Márcia; Turra, Alexander; Gorman, Daniel

    2017-09-15

    This study assessed the concentration and composition of Polycyclic Aromatic Hydrocarbons (PAHs) in plastic pellets, collected from sandy beaches and considered different resin and colour tones. Results showed that polyethylene pellets, while displaying a greater range of total PAH concentrations did not differ significantly from polypropylene pellets. More importantly, both resin types demonstrated predictable increases in total PAH across a spectrum of darkening colour tones. Multivariate comparisons of 36 PAH groups, further showed considerable variability across resin type and colour, with lighter coloured pellets comprising lower molecular weight, while darker pellets contained higher weight PAHs. Overall, we show predictable variation in PAH concentrations and compositions of plastic pellets of different ages and resin types that will directly influence the potential for toxicological effects. Our findings suggest that monitoring programs should take these attributes into account when assessing the environmental risks of microplastic contamination of marine and coastal habitats. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Synthesis, properties and applications of interacting blends of acrylated novalac epoxy resin based poly(ester-amides and vinyl ester

    Directory of Open Access Journals (Sweden)

    Pragnesh N. Dave

    2016-09-01

    Full Text Available Epoxy resin based unsaturated poly(ester-amide resins (UPEAs were prepared by the reported method. These UPEAs were then treated with acryloyl chloride to afford acrylated UPEAs resin (i.e. AUPEAs. Interacting blends of equal proportional AUPEAs and vinyl ester epoxy (VE resin were prepared. APEAs and AUPEAs were characterized by elemental analysis, molecular weight determined by vapor pressure osmometer and by IR spectral study and by thermogravimetry. The curing of interacting blends was monitored on differential scanning calorimeter (DSC. Based on DSC data in situ glass reinforced composites of the resultant blends have been prepared and characterized for mechanical, electrical and chemical properties. Unreinforced blends were characterized by thermogravimetry (TGA.

  5. Shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Hamanaka, Ippei; Shimizu, Hiroshi; Takahashi, Yutaka

    2013-09-01

    This study investigated the shear bond strength of an autopolymerizing repair resin to injection-molded thermoplastic denture base resins. Four injection-molded thermoplastic resins (two polyamides, a polyethylene terephthalate copolymer and a polycarbonate) were used in this study. The specimens were divided into eight groups according to the type of surface treatment given: (1) no treatment, (2) air abrasion with alumina, (3) dichloromethane, (4) ethyl acetate, (5) 4-META/MMA-TBB resin, (6) alumina and 4-META/MMA-TBB resin, (7) tribochemical silica coating or (8) tribochemical silica coating and 4-META/MMA-TBB resin. Half of the specimens in groups 1, 5, 6 and 8 were thermocycled for 10,000 cycles in water between 5-55°C with a dwell time of 1 min at each temperature. The shear bond strengths were determined. The shear bond strengths to the two polyamides treated with alumina, dichloromethane and ethyl acetate and no treatment were very low. The greatest post-thermocycling bond strengths to polyamides were recorded for the specimens treated with tribochemical silica coating and 4-META/MMA-TBB resin (PA12: 16.4 MPa, PACM12: 17.5 MPa). The greatest post-thermocycling bond strengths to polyethylene terephthalate copolymer and polycarbonate were recorded for the treatment with alumina and 4-META/MMA-TBB resin (22.7 MPa, 20.8 MPa). Polyamide was exceedingly difficult to bond to an autopolymerizing repair resin; the shear bond strength improved using tribochemical silica coating followed by the application of 4-META/MMA-TBB resin. Both polyethylene terephthalate copolymer and polycarbonate were originally easy to bond to an autopolymerizing repair resin. However, with 4-META/MMA-TBB resin, the bond was more secure.

  6. Magnetic ion-exchange resin treatment: Impact of water type and resin use

    OpenAIRE

    Mergen, Maxime Rodolphe Denis; Jefferson, Bruce; Parsons, Simon A.; Jarvis, Peter

    2008-01-01

    Three raw waters of fundamentally different natural organic matter (NOM) character were treated by magnetic resin using a bench-scale method designed to mimic how the resin is used in continuous operation. Increasing water hydrophobicity resulted in reduced dissolved organic carbon (DOC) removal with removal of 56%, 33% and 25% for waters containing 21%, 50% and 75% hydrophobic NOM, respectively. Study of consecutive resin uses showed that the NOM in the hydrophobic water ha...

  7. 5-year clinical performance of resin composite versus resin modified glass ionomer restorative system in non-carious cervical lesions

    DEFF Research Database (Denmark)

    Franco, Eduardo Batista; Benetti, Ana Raquel; Ishikiriama, Sérgio Kiyoshi

    2006-01-01

    To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions.......To comparatively assess the 5-year clinical performance of a 1-bottle adhesive and resin composite system with a resin-modified glass ionomer restorative in non-carious cervical lesions....

  8. 21 CFR 175.380 - Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins.

    Science.gov (United States)

    2010-04-01

    ...-isopropylidenediphenol-epichlorohydrin epoxy resins. 175.380 Section 175.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... Xylene-formaldehyde resins condensed with 4,4′-isopropylidenediphenol-epichlorohydrin epoxy resins. The...′-isopropylidenediphenol-epichlorohydrin epoxy resins, to which may have been added certain optional adjuvant substances...

  9. [Purification of total paeony glycoside by macroporous resin with double indices of albiflorin and paeoniflorin].

    Science.gov (United States)

    Dou, Zhi-Hua; Luo, Lin; Lu, Dan

    2009-08-01

    To investigate the purification process of total paeony glycoside (TPG) from Radix Paeoniae Rubra by macroporous resin with double indices of albiflorin and paeoniflorin. HPLC was used for simultaneous determination of albiflorin and paeoniflorin and the results were used as main indices to investigate the technological parameters for purifying TPG by D101 macroporous resin. Then the result was verified by ampliate test. The applicable technological conditions of purification for TPG by D101 macroporous resin were as follows: the concentrations of albiflorin and paeoniflorin in original solution were 0.12 mg/mL, 2.58 mg/mL with a flow rate of 3.6 BV/h, and the adsorption capacity were 0.71 mg/mL, 15.43 mg/mL, respectively. The eluant was 20% alcohol with 8 times of resin volume, and the elution ratio were 72.18%, 90.84%, respectively. The result of ampliate test accorded with that of small test. D101 macroporous adsorption resin can be used to purify TPG from crude extracts of Radix Paeoniae Rubra.

  10. Simultaneous separation and detection of actinides in acidic solutions using an extractive scintillating resin.

    Science.gov (United States)

    Roane, J E; DeVol, T A

    2002-11-01

    An extractive scintillating resin was evaluated for the simultaneous separation and detection of actinides in acidic solutions. The transuranic extractive scintillating (TRU-ES) resin is composed of an inert macroporous polystyrene core impregnated with organic fluors (diphenyloxazole and 1,4-bis-(4-methyl-5-phenyl-2-oxazolyl)benzene) and an extractant (octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide in tributyl phosphate). The TRU-ES resin was packed into FEP Teflon tubing to produce a flow cell (0.2-mL free column volume), which is placed into a scintillation detection system to obtain pulse height spectra and time series data during loading and elution of actinides onto/from the resin. The alpha-particle absolute detection efficiencies ranged from 77% to 96.5%, depending on the alpha energy and quench. In addition to the on-line analyses, off-line analyses of the effluent can be conducted using conventional detection methods. The TRU-ES resin was applied to the quantification of a mixed radionuclide solution and two actual waste samples. The on-line characterization of the mixed radionuclide solution was within 10% of the reported activities whereas the agreement with the waste samples was not as good due to sorption onto the sample container walls and the oxidation state of plutonium. Agreement between the on-line and off-line analyses was within 35% of one another for both waste samples.

  11. SuperLig® 639 Resin Performance using 8 Molar LAW Feed

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Williams, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Restivo, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-15

    All prior testing with SuperLig® 639 has been done with the aqueous concentration of LAW at ~5 M [Na+], where the resin sinks, and can be used in a conventional down-flow column orientation. However, the aqueous LAW stream from the Waste Treatment Plant is expected to be ~8 M [Na+]. The resin would float in this higher density liquid, potentially disrupting the ability to achieve a good decontamination due to poor packing of the resin that leads to channeling. Testing was completed with a higher salt concentration in the feed simulant (7.8 M [Na+]) in an engineering-scale apparatus with two columns, each containing ~0.9 L of resin. Testing of this system used a simulant of the LAW solution, and substituted ReO4 - as a surrogate for TcO4 -. Results were then compared using computer modeling. Bench-scale testing was also performed, and examined an unconstrained resin bed, while engineering-scale tests used both constrained and unconstrained beds in a two-column, lead and lag sequential arrangement.

  12. The strengthening of resin cemented dental ceramic materials

    OpenAIRE

    Hooi, Paul

    2013-01-01

    The aim of the current investigation was to advance the understanding of the mechanism of resin-strengthening conferred to dental ceramic materials by resin-based composite materials. The investigation is presented as a series of manuscripts. In the first study (Manuscript 3.1), dental porcelain disc-shaped specimens were resin-coated with three resin-based composite materials with different flexural moduli at discrete resin thicknesses. The discs were loaded to failure in a biaxial flexure t...

  13. Pengaruh Sifat-Sifat Fisik Resin Akrilik Terhadap Basis Protesa

    OpenAIRE

    Amriani Syahfitri

    2008-01-01

    Saat ini resin akrilik banyak digunakan secara umum untuk konstruksi gigi tiruan. Sebagai bahan basis prothesa, penggunaan resin akrilik terutama resin heat cured adalah yang paling sering digunakan selain bernilai estetis, juga lebih ekonomis. Pada prothesa yang ideal memerlukan suatu basis yang kuat, Syarat- syarat basis protesa tidak semuanya dapat dipenuhi oleh basis resin akrilik. Sifat-sifat fisik resin akrilik mempunyai pengaruh terhadap basis protesa. Untuk menghindari k...

  14. Dental repair material: a resin-modified glass-ionomer bioactive ionic resin-based composite.

    Science.gov (United States)

    Croll, Theodore P; Berg, Joel H; Donly, Kevin J

    2015-01-01

    This report documents treatment and repair of three carious teeth that were restored with a new dental repair material that features the characteristics of both resin-modified glass-ionomer restorative cement (RMGI) and resin-based composite (RBC). The restorative products presented are reported by the manufacturer to be the first bioactive dental materials with an ionic resin matrix, a shock-absorbing resin component, and bioactive fillers that mimic the physical and chemical properties of natural teeth. The restorative material and base/liner, which feature three hardening mechanisms, could prove to be a notable advancement in the adhesive dentistry restorative materials continuum.

  15. Nanosilica Modification of Elastomer-Modified VARTM Epoxy Resins for Improved Resin and Composite Toughness

    National Research Council Canada - National Science Library

    Robinette, Jason; Bujanda, Andres; DeSchepper, Daniel; Dibelka, Jessica; Costanzo, Philip; Jensen, Robert; McKnight, Steven

    2007-01-01

    Recent publications have reported a synergy between rubber and silica in modified epoxy resins that results in significantly improved fracture toughness without reductions in other material properties...

  16. Synthesis of improved phenolic and polyester resins

    Science.gov (United States)

    Delano, C. B.

    1980-01-01

    Thirty-seven cured phenolic resin compositions were prepared and tested for their ability to provide improved char residues and moisture resistance over state of the art epoxy resin composite matrices. Cyanate, epoxy novolac and vinyl ester resins were investigated. Char promoter additives were found to increase the anaerobic char yield at 800 C of epoxy novolacs and vinyl esters. Moisture resistant cyanate and vinyl ester compositions were investigated as composite matrices with Thornel 300 graphite fiber. A cyanate composite matrix provided state of the art composite mechanical properties before and after humidity exposure and an anaerobic char yield of 46 percent at 800 C. The outstanding moisture resistance of the matrix was not completely realized in the composite. Vinyl ester resins showed promise as candidates for improved composite matrix systems.

  17. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    Purpose/aim: To evaluate in a randomized controlled study the 5-year clinical durability of a flowable resin composite bulk-fill technique in Class I and Class II restorations. Materials and methods: 38 pairs Class I and 62 pairs Class II restorations were placed in 44 male and 42 female (mean age...... 52.4 years). Each patient received at least two, as similar as possible, extended Class I or Class II restorations. In all cavities, a 1-step self-etch adhesive (Xeno V+) was applied. Randomized, one of the cavities of each pair received the flowable bulk-filled resin composite (SDR), in increments...... up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...

  18. 21 CFR 177.1380 - Fluorocarbon resins.

    Science.gov (United States)

    2010-04-01

    ...) Chlorotrifluoroethylene-1,1-difluoroethylene-tetrafluoroethylene co-polymer resins produced by copolymerization of..., Extrusion, and Coating Materials,” which is incorporated by reference in accordance with 5 U.S.C. 552(a) and...

  19. Liquid Resins With Low VOC Emissions

    National Research Council Canada - National Science Library

    LaScala, John J; Sands, James M; Palmese, Guiseppe R

    2004-01-01

    .... The polymer properties were similar to that of commercial resins, including Tg greater than 120 C, flex strength greater than 100 MPa, modulus of approximately 3 GPa, and fracture toughness greater than 200 J/m2...

  20. 21 CFR 177.1655 - Polysulfone resins.

    Science.gov (United States)

    2010-04-01

    ... by osmotic pressure in monochlorobenzene; or (2) 1,1′-Sulfonylbis[4-chlorobenzene] polymer with 4,4... determined by osmotic pressure in dimethylformamide. (b) The basic polysulfone resins identified in paragraph...