Sample records for resilient denture liner

  1. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  2. Influence of the mechanical properties of resilient denture liners on the retention of overdenture attachments.

    Science.gov (United States)

    Kubo, Keitaro; Koike, Takashi; Ueda, Takayuki; Sakurai, Kaoru

    2018-03-15

    Information is lacking about the selection criteria for silicone resilient denture liners applied as a matrix material for attachments on overdentures. The purpose of this in vitro study was to investigate the mechanical properties of silicone resilient denture liners and their influence on the initial retention force of overdenture attachments and the reduction in retention force over time. Nine types of silicone resilient denture liner were injected and fixed to the matrix section of an experimental denture base. They were then fitted to an epoxy resin model that simulated the residual ridge with a patrix ball attachment (n=10). The retention force of the denture was measured with a digital force gauge, and the maximum force of traction (N) was regarded as the initial retention force. The retention force reduction (N) after repeated insertion and removal (n=5) was calculated by subtracting the retention force after 3348 cycles (3-year simulated insertion and removal) from the initial retention force. The intaglio of the matrix was observed with a scanning electron microscope (SEM) before and after the 3348 cycles. Four mechanical properties (hardness, strain-in-compression, tensile strength, and arithmetic mean roughness) of the resilient denture liners were measured. One-way ANOVA of the initial retention force of each lining material was performed, followed by the Scheffe test (α=.05). Pearson correlation analysis was used (α=.05) to analyze correlations of the initial retention force with the retention force reduction after insertion and removal and the mechanical properties of each material. Multiple regression analysis with the stepwise method extracted the initial retention force and the retention force reduction as dependent variables, and the resilient denture liner mechanical properties as explanatory variables (α=.05). The initial retention force of the resilient denture liners was 1.3 to 5.4 N. Multiple comparisons showed significant differences in

  3. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment.

    Science.gov (United States)

    Kaur, Harsimran; Datta, Kusum

    2015-01-01

    To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA) were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P) and rest 80 to heat-cured resilient liner (Molloplast B). Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm) in the space provided by a spacer of 3 mm, thermocycled (5-55°C) for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student's t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B) increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  4. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment

    Directory of Open Access Journals (Sweden)

    Harsimran Kaur

    2015-01-01

    Full Text Available Purpose: To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Materials and Methods: Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P and rest 80 to heat-cured resilient liner (Molloplast B. Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm in the space provided by a spacer of 3 mm, thermocycled (5-55°C for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. Results: One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student′s t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Conclusion: Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  5. Creep and stress relaxation behavior of two soft denture liners.

    Science.gov (United States)

    Salloum, Alaa'a M

    2014-03-01

    Numerous investigators stated the indications of soft denture lining materials; but no one determined the indications of these materials according to their chemical structure. The purpose of this investigation was to evaluate the viscoelastic properties of acrylic and silicon lining materials. This study investigated and compared viscoelastic properties of two resilient denture lining materials. Tested materials were laboratory processed; one of them was silicone-based liner product (Molloplast-B), and the other was plasticized acrylic resin (Vertex™ Soft). Twenty cylindrical specimens (10-20 mm in length, 11.55 mm in diameter) were fabricated in an aluminum mold from each material for creep and stress relaxation testing (the study of viscoelastic properties). Tests were performed by using the universal testing machine DY-34. Collected data were analyzed with t test statistics for statistically significant differences at the 95 % confidence level. There was a clear difference in creep and stress relaxation behavior between acrylic and silicone liners. Statistical study of Young's moduli illustrated that Vertex™ Soft was softer than Molloplast-B. On the other hand, the results explained that the recovery of silicone material was better than of acrylic one. The creep test revealed that the plasticized acrylic resin lining material exhibited considerable creep, whereas silicone-based liner exhibited elastic behavior. Besides, the stress relaxation test showed that relaxation of the plasticized acrylic resin material was bigger than of the silicone-based liner.

  6. The compatibility of denture cleansers and resilient liners Influência dos agentes químicos de limpeza sobre reembasadores resilientes de próteses

    Directory of Open Access Journals (Sweden)

    Luciana Valadares Oliveira

    2006-08-01

    Full Text Available PURPOSE: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials. MATERIALS AND METHODS: Three resilient liners, Luci Sof® (Dentsply, Molloplast-B® (Dentax, and Sofreliner® (Tokuyama, and two denture cleansers, Efferdent® (Warner-Lamber, and 0.5% alkaline hypochlorite preparation were used. Twenty specimens of each material were prepared, measuring 25X15X3mm. Two denture cleansing approaches were used: 1 alkaline hypochlorite, for 20 minutes; 2 alkaline peroxide, for 30 minutes. This procedure was repeated 8 times a day, during 90 days. The specimens were evaluated before and after 360 and 720 cycles, to simulate 1 and 2 years of clinical cleaning procedures, respectively. The Shore A hardness was evaluated in a durometer (Teclock GS-709A, with a penetrating load of 10N for 1 second. Any macroscopic changes, such as loss of color or alteration in surface texture were recorded by one observer. All numeric data were subject to ANOVA with repeated measures followed by Tukey's test (alpha= 0.05. RESULTS: All materials were significantly different, independently to time and treatment. Initially, Luci Sof® and Sofreliner® immersed in either hypochlorite or peroxide increased the hardness mean values significantly. These hardness mean values decreased significantly after 720 cycles. Molloplast-B® showed no significant difference after the treatments, in any time. CONCLUSIONS: Denture cleansers had no effect on hardness of the resilient denture liners evaluated after 2 years of in vivo simulated conditions of hygiene. Sofreliner® was the smoothest material before and after all treatments.PROPOSIÇÃO: A maior desvantagem dos materiais reembasadores resilientes é a dificuldade em mantê-los limpos. Esse trabalho avaliou o efeito de agentes de limpeza sobre a dureza de reembasadores resilientes

  7. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou

    2012-01-01

    This report aimed to compare prosthetic aspects and patient satisfaction during a 3-year randomized clinical trial of bar- and implant-retained mandibular overdentures attached with either resilient liners or clips. Thirty edentulous male patients (mean age: 62.5 years) received two implants in the anterior mandible after being allocated into two equal groups (according to attachment type received) using balanced randomization. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I) or silicone resilient liners (group II). Subjects indicated satisfaction with their prostheses using a questionnaire and visual analog scale. Patient satisfaction and prosthetic complications were recorded for both attachments at 6 months and 1 and 3 years after overdenture insertion. Comfort and stability with the maxillary denture and ease of hygiene procedures were rated higher in group II, while ease of handling the dentures was rated higher in group I. No significant differences in other parameters of patient satisfaction between groups were noted after 3 years. The mean number of prosthetic adjustments and repairs in group I (11.9) was significantly higher (P = .00) compared to that in group II (4.8). The most common complication in group I was clip wear, while separation of the resilient liner from the denture base was the most common problem in group II. Hyperplasia under the bar and flabby ridge in the maxilla occurred significantly more often in group I compared to group II. Resilient liner-retained mandibular overdentures had comparable patient satisfaction, less prosthetic maintenance and costs, and less soft tissue complications when compared to clip-retained ones after 3 years.

  8. Effect of resilient liner on masticatory efficiency and general patient satisfaction in completely edentulous patients

    DEFF Research Database (Denmark)

    Mangtani, Nidhi; Pillai, Rajath; Babu, Dinesh

    2015-01-01

    Objectives: To assess the effect of resilient lined denture on patient masticatory efficiency, general patient satisfaction and denture quality as compare to conventional complete denture over a period of one year. Material and methodology: A total of 28 completely edentulous patients (14 males...... denture liner – group 2). All patients were clinically evaluated to assess the denture quality, and administered questionnaires for masticatory efficiency and patients general satisfaction level at three intervals i.e. one month (T0), 6 months (T1) and 1 year post-insertion (T2). Results: Statistical...... masticatory efficiency improved significantly over time in controls, while in experimental group masticatory efficiency remained the same (p>.05) for almost all the questions. Patient general satisfaction score at different time intervals for each question showed no significant difference (P>.05) on inter...

  9. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    Science.gov (United States)

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  10. Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

    Science.gov (United States)

    Farzin, M; Bahrani, F; Adelpour, E

    2013-09-01

    One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.

  11. Candida albicans biofilms and MMA surface treatment influence the adhesion of soft denture liners to PMMA resin

    Directory of Open Access Journals (Sweden)

    Martinna de Mendonça e Bertolini

    2014-01-01

    Full Text Available The effect of Candida albicans biofilms and methyl methacrylate (MMA pretreatment on the bond strength between soft denture liners and polymethyl methacrylate (PMMA resin was analyzed. Specimens were prepared and randomly divided with respect to PMMA pretreatment, soft liner type (silicone-based or PMMA-based, and presence or absence of a C. albicans biofilm. Samples were composed of a soft denture liner bonded between two PMMA bars. Specimens (n = 10 were incubated to produce a C. albicans biofilm or stored in sterile PBS for 12 days. The tensile bond strength test was performed and failure type was determined using a stereomicroscope. Surface roughness (SR and scanning electron microscopy (SEM analysis were performed on denture liners (n = 8. Highest bond strength was observed in samples containing a silicone-based soft liner and stored in PBS, regardless of pretreatment (p < 0.01. Silicone-based specimens mostly underwent adhesive failures, while samples containing PMMA-based liners predominantly underwent cohesive failures. The silicone-based specimens SR decreased after 12 days of biofilm accumulation or PBS storage, while the SR of PMMA-based soft liners increased (p < 0.01. The PMMA-based soft liners surfaces presented sharp valleys and depressions, while silicone-based specimens surfaces exhibited more gentle features. In vitro exposure to C. albicans biofilms reduced the adhesion of denture liners to PMMA resin, and MMA pretreatment is recommended during relining procedures.

  12. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    Science.gov (United States)

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36

  13. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface

    Directory of Open Access Journals (Sweden)

    Ana Paula Coelho Vieira

    2010-09-01

    Full Text Available This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min, 0.5% sodium hypochlorite (10 min or distilled water (control; 15 min. After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL. Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05. Results of cell count estimation showed significant differences in cleanliness among the treatments (p 0.05 was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p < 0.001. Sodium hypochlorite was the only treatment that removed biofilm efficiently, since no viable cells were found after its use. In conclusion, alkaline peroxide denture cleansers were not effective in removing Candida spp. biofilm from denture liner surfaces and preventing biofilm recolonization.

  14. Effect of long-time immersion of soft denture liners in water on viscoelastic properties.

    Science.gov (United States)

    Iwasaki, Naohiko; Yamaki, Chisato; Takahashi, Hidekazu; Oki, Meiko; Suzuki, Tetsuya

    2017-09-26

    Aim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months. Viscoelastic properties, which were instantaneous and delayed elastic displacements, viscous flow, and residual displacement, were determined using a creep meter, and analyzed with 2-way analysis of variance and Tukey's comparison (α=0.05). Viscoelastic properties and their time-dependent changes were varied among materials examined. The observed viscoelastic properties of three from six silicone-based liners did not significantly change after 6-month immersion, but those of two acrylic resin-based liners significantly changed with the increase of immersion time. However, the sum of initial instantaneous elastic displacement and delayed elastic displacement of two acrylic resin-based liners during 6-month immersion changed less than 10%, which might indicate clinically sufficient elastic performance.

  15. Influence of ozone and paracetic acid disinfection on adhesion of resilient liners to acrylic resin.

    Science.gov (United States)

    Ekren, Orhun; Ozkomur, Ahmet

    2016-08-01

    The aim of this study was to evaluate the effect of paracetic acid (PAA) and ozone disinfection on the tensile bond strength (TBS) of silicone-based resilient liners to acrylic resins. One hundred and twenty dumbbell shaped heat-polymerized acrylic resins were prepared. From the mid segment of the specimens, 3 mm of acrylic were grinded off and separated parts were reattached by resilient liners. The specimens were divided into 2 control (control1, control7) and 4 test groups of PAA and ozone disinfection (PAA1, PAA7, ozone1 and ozone7; n=10). While control groups were immersed in distilled water for 10 min (control1) and 7 days (control7), test groups were subjected to PAA (16 g/L) or ozone rich water (4 mg/L) for 1 cycle (10 min for PAA and 60 min for ozone) per day for 7 days prior to tensile tests. Measurements of the TBS were analyzed using 3-way ANOVA and Tukey's HSD test. Adhesive strength of Mollosil decreased significantly by application of ozone disinfection. PAA disinfection had no negative effect on the TBS values of Mollosil and Molloplast B to acrylic resin. Single application of ozone disinfection did not have any negative effect on TBS values of Molloplast B, but prolonged exposure to ozone decreased its adhesive strength. The adhesion of resilient liners to acrylic was not adversely affected by PAA disinfection. Immersion in ozonated water significantly decreased TBS of Mollosil. Prolonged exposure to ozone negatively affects adhesion of Molloplast B to denture base materials.

  16. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface.

    Science.gov (United States)

    Vieira, Ana Paula Coelho; Senna, Plínio Mendes; Silva, Wander José da; Del Bel Cury, Altair Antoninha

    2010-01-01

    This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate)-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min), 0.5% sodium hypochlorite (10 min) or distilled water (control; 15 min). After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL). Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05). Results of cell count estimation showed significant differences in cleanliness among the treatments (p 0.05) was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p recolonization.

  17. Developing the procedure of modifying the denture soft liner by silver nanoparticles.

    Science.gov (United States)

    Chladek, Grzegorz; Barszczewska-Rybarek, Izabela; Lukaszczyk, Jan

    2012-01-01

    Colonization of denture soft lining materials by fungi and denture plaque leads to infections of mucosa. Microorganisms such as Candida albicans colonize not only the surface of the soft liners, but they also penetrate inside those materials. Therefore the use of common disinfectants, e.g., surface active cleaners, is not a perfect solution for keeping a proper hygiene of soft linings. Modifying soft lining by silver nanoparticles (AgNP) seems to be a right way to overcome those problems. The procedure of modifying two-component silicone material by silver nanoparticles (AgNP) is presented in the article. The solubility tests for both material components have been carried out in the first stage of examinations. On the basis of test results, a solvent has been selected, being a dispersion medium for AgNPs and both soft liner components. The effective method for evaporating a solvent from the composition has been developed. Material components with various AgNP concentrations (10, 20, 40, 80, 120 and 200 ppm) have been obtained. Cured samples of the composites have been examined by SEM to confirm the effectiveness of the procedure.

  18. Long-term clinical and prosthetic outcomes of soft liner and clip attachments for bar/implant overdentures: a randomised controlled clinical trial.

    Science.gov (United States)

    ELsyad, M A; Shaheen, N H; Ashmawy, T M

    2017-06-01

    Long-term clinical and prosthetic outcomes of soft liner attachments for bar/implant overdentures were not sufficiently investigated. The aim of this trial was to evaluate clinical and prosthetic outcomes of resilient liner and clip attachments for bar/implant-retained mandibular overdenture after 7 years. Thirty edentulous male participants received two implants in the canine areas of the mandible. Three months later, implants were splinted with a resilient bar. Mandibular overdentures were connected to the bars with either clip (CR group, n = 15) or resilient liner (RR group, n = 15) attachments. Plaque index (PI), gingival index (GI), probing depth (PD), vertical bone loss (VBL), horizontal bone loss (HBLO) and prosthetic complications (PCs) were evaluated at denture delivery (T0), 6 (T 6m ), 12 (T1), 24 (T2), 36 (T3), 48 (T4), 60 (T5), 72 (T6) and 84 (T7) months after insertion. PI and GI increased significantly with time for CR and decreased significantly for RR (P overdentures than clip attachments in terms of peri-implant tissue health and prosthetic complications after 7 years. © 2017 John Wiley & Sons Ltd.

  19. Effect of Incorporation of Antifungal Agents on the Ultimate Tensile Strength of Temporary Soft Denture Liners.

    Science.gov (United States)

    Neppelenbroek, Karin Hermana; Lima, Jozely Francisca Mello; Hotta, Juliana; Galitesi, Lucas Lulo; Almeida, Ana Lucia Pompéia Fraga; Urban, Vanessa Migliorini

    2018-02-01

    To investigate the ultimate tensile strength of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314) determined in previous microbiological research. Dumbbell-shaped specimens (n = 7) with a central cross-sectional area of 6 × 3 × 33 mm were produced by Softone and Trusoft, without (control) or with incorporation of drugs in powder form at MICs for C. albicans biofilm (per g of material powder): nystatin (0.032 g), chlorhexidine diacetate (0.064 g), ketoconazole (0.128 g), miconazole (0.256 g), and itraconazole (0.256 g). After plasticization, specimens were immersed in distilled water at 37°C for 24 hours, 7 or 14 days, and then tested in tension in a universal testing machine at 40 mm/min. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA and Tukey's test (α = 0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (p 0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials resulted in significantly lower elongation percentages compared to the other antifungal agents and control (p 0.05). The addition of the nystatin, chlorhexidine, and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the tensile strength and elongation percentage of the temporary soft denture liner materials up to 14 days. © 2017 by the American College of Prosthodontists.

  20. Oral health-related quality of life of edentulous patients after complete dentures relining

    Directory of Open Access Journals (Sweden)

    Krunić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Tooth loss affects oral health-related life quality. More than a third of edentulous patients are not fully satisfied with their complete dentures and mainly complain of insufficient stability, retention, and pain during mastication. Solving the problem may include relining by materials that are based on silicone or acrylic. The aim of this study was to determine the level of patients’ satisfaction before and after relining upper dentures with soft and rigid liners. Methods. The patients (n = 24 were divided into two study groups. Maxillary denture relining of the first group of patients was performed with hard acrylic based resins while in the second group of patients complete denture was relined with a silicone-based soft liner. They were asked the questions from the specifically adapted the Oral Health Impact Profile Questionnaire for edentulous patients before and three months after relining dentures. Results. After relining the patients showed a higher degree of satisfaction with their dentures in all the tested domains (masticatory function, psychological discomfort, social disability and retention and hygiene. The patients with soft denture relines were more satisfied. Conclusion. Relining of maxillary complete dentures significantly positively impacts the quality of life of patients in all the tested domains (masticatory function, psychological discomfort, social disability, pain and oral hygiene. Better results were achieved using a silicone-based soft liner, which recommends it as the material of choice for relining dentures.

  1. Liquid supported denture-management of flabby ridges

    Directory of Open Access Journals (Sweden)

    Pranav V Mody

    2012-01-01

    Full Text Available The ideal properties of a denture are adequate rigidity on polished surface to bear masticatory forces and at the same time, flexibility and softness on the tissue surface for proper and even distribution of masticatory forces. The problem with conventional denture is rigidity of tissue surface; leads to uneven distribution of load. This drawback even worsens in the case of flabby, atrophic and unemployed ridges with excessive bone resorption.The liquid supported denture allows continued adaptation and eliminates the disadvantages of denture designs based on the application of temporary tissue conditioners or soft liners.

  2. A comparative evaluation of effect on water sorption and solubility of a temporary soft denture liner material when stored either in distilled water, 5.25% sodium hypochlorite or artificial saliva: An in vitro study

    Directory of Open Access Journals (Sweden)

    Aditi Garg

    2016-01-01

    Full Text Available Introduction: Soft denture liners have a key role in modern removable prosthodontics since they restore health to inflamed and abused mucosa by redistribution of forces transmitted to the edentulous ridges. The most common problems encountered using soft denture liners are water sorption and solubility when in contact with saliva or storage media. These problems are associated with swelling, distortion, support of Candida albicans growth, and stresses at the liner/denture base interface that reduces the bond strength. Objective: To evaluate the water sorption and solubility of commercially available acrylic based self cure soft denture lining material (GC RELINE™ Tissue Conditioner after immersion in three different storage media (distilled water, Shellis artificial saliva, 5.25% sodium hypochlorite disinfectant solution at time interval of 4, 7, 11, and 15 days. Material and Methods: The study involved preparation of artificial saliva using Shellis formula. A total 45 standardized samples of the material (GC RELINE™ were prepared in disk form (15 mm in diameter and 2 mm in thickness. The study was divided into three groups with storage in Control (distilled water, Shellis artificial saliva, and 5.25% sodium hypochlorite. Samples were dried in a desiccator and weighed in the analytical balance to measure the initial weight (mg/cm2 of the disks (W1. The first groups (15 samples were placed in 30 ml distilled water (Group A at 37΀C, second group 30 ml of artificial saliva (Group B and third group in 5.25% sodium hypochlorite (Group C. Disks were removed from disinfectant after 5 min and placed in 30 ml distilled water. On days 4, 7, 11, and 15, all samples were removed from their containers and reweighed to measure the weight (mg/cm2 of the disks after sorption (W2. The solubility was measured by placing the disks back in the desiccator after each sorption cycle and drying them to constant weight in the desiccator. These values were weight

  3. Effects of undecylenic acid released from denture liner on Candida biofilms.

    Science.gov (United States)

    Gonçalves, L M; Del Bel Cury, A A; Sartoratto, A; Garcia Rehder, V L; Silva, W J

    2012-10-01

    Denture liners (DL) are easily colonized by Candida spp. In an attempt to prevent biofilm colonization, manufacturers have incorporated undecylenic acid (UDA) into DL. In this in vitro study, the effects of UDA released from DL on Candida biofilms were investigated. The concentrations of UDA released from commercial DL were determined by gas chromatography-mass spectrometry (GC-MS). Minimum inhibitory concentration (MIC) and minimum fungistatic concentration (MFC) tests were performed for C. albicans or C. glabrata, with UDA for comparison with the concentrations released from DL. Specimens of DL with (experimental group) and without UDA (control group) were fabricated, and Candida biofilms were developed on DL surfaces. Biofilms were evaluated by cell counts, metabolic activity, structure, and secretion of proteinase or phospholipase. The concentrations of UDA released were within the MIC and MFC ranges. In the presence of UDA, C. albicans biofilms were thinner and had lower numbers of viable and active cells, although no significant enzymatic changes were observed relative to the control group (p > 0.05). In contrast, C. glabrata biofilms exhibited higher cell counts and greater metabolic activity and also increased proteinase activity in the presence of UDA relative to the control group (p < 0.05). Overall, UDA did not prevent Candida biofilm formation.

  4. Going Beyond the Conventional Approach - Liquid Supported Denture: A Case Report

    Directory of Open Access Journals (Sweden)

    Dipti S Shah

    2013-01-01

    Full Text Available Background: The concept of conditioning oral mucosa has gained momentum over the last few years. Different tissue conditioning materials and soft liners have been used for this purpose. But the limitations of these materials has led to the introduction of liquid-supported dentures, which is a newer alternative to conventional complete denture prosthesis in cases with inflamed tissues, atrophic and severely resorbed edentulous ridges. Liquid supported Denture consists of a base which is covered with a preshaped close fitting flexible foil containing a thin film of high viscosity liquid which cushions the underlying tissues. This case report describes fabrication of liquid-supported dentures for patients with compromised tissues.

  5. Biofilm development by blastospores and hyphae of Candida albicans on abraded denture acrylic resin surfaces.

    Science.gov (United States)

    Jackson, Sarah; Coulthwaite, Lisa; Loewy, Zvi; Scallan, Anthony; Verran, Joanna

    2014-10-01

    Candida albicans is a known etiologic agent of denture stomatitis. Candida hyphae exhibit the ability to respond directionally to environmental stimuli. This characteristic is thought to be important in the penetration of substrata such as resilient denture liners and host epithelium. It has been suggested that hyphal production also enhances adhesion and survival of Candida on host and denture surfaces. Surface roughness, in addition, can enhance adhesion where stronger interactions occur between cells and surface features of similar dimensions. The purpose of this study was to assess the development of hyphal and blastospore biofilms on abraded denture acrylic resin specimens and measure the ease of removal of these biofilms. Biofilms were grown for 48 hours on abraded 1-cm² denture acrylic resin specimens from adhered hyphal phase C albicans or from adhered blastospores. Subsequently, all specimens were stained with Calcofluor White and examined with confocal scanning laser microscopy. Biofilms were removed by vortex mixing in sterile phosphate buffered saline solution. Removed cells were filtered (0.2-μm pore size). Filters were dried at 37°C for 24 hours for dry weight measurements. Any cells that remained on the acrylic resin specimens were stained with 0.03% acridine orange and examined with epifluorescence microscopy. Biofilms grown from both cell types contained all morphologic forms of C albicans. Although the underlying surface topography did not affect the amount of biofilm produced, biofilms grown from hyphal phase Candida were visibly thicker and had greater biomass (Phyphae in early Candida biofilms increased biofilm mass and resistance to removal. Increased surface roughness enhances retention of hyphae and yeast cells, and, therefore, will facilitate plaque regrowth. Therefore, minimization of denture abrasion during cleaning is desirable. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All

  6. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    Science.gov (United States)

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the

  7. Undecylenic Acid Inhibits Morphogenesis of Candida albicans

    OpenAIRE

    McLain, Nealoo; Ascanio, Rhoda; Baker, Carol; Strohaver, Robert A.; Dolan, Joseph W.

    2000-01-01

    Resilient liners are frequently used to treat denture stomatitis, a condition often associated with Candida albicans infections. Of 10 liners tested, 2 were found to inhibit the switch from the yeast form to hyphae and a third was found to stimulate this switch. The inhibitor was determined to be undecylenic acid.

  8. Undecylenic acid inhibits morphogenesis of Candida albicans.

    Science.gov (United States)

    McLain, N; Ascanio, R; Baker, C; Strohaver, R A; Dolan, J W

    2000-10-01

    Resilient liners are frequently used to treat denture stomatitis, a condition often associated with Candida albicans infections. Of 10 liners tested, 2 were found to inhibit the switch from the yeast form to hyphae and a third was found to stimulate this switch. The inhibitor was determined to be undecylenic acid.

  9. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment.

    Science.gov (United States)

    Glisić, Mirko; Stamenković, Dragoslav; Grbović, Aleksandar; Todorović, Aleksandar; Marković, Aleksa; Trifković, Branka

    2016-01-01

    Differences between the tooth and implant response to load can lead to many biological and technical implications in the conditions of occlusal forces. The objective of this study was to analyze load distribution in tooth/implant-supported fixed partial dentures with the use of resilient TSA (Titan Shock Absorber, BoneCare GmbH, Augsburg, Germany) abutment and conventional non-resilient abutment using finite element method. This study presents two basic 3D models. For one model a standard non-resilient abutment is used, and on the implant of the second model a resilient TSA abutment is applied. The virtual model contains drawn contours of tooth, mucous membranes, implant, cortical bones and spongiosa, abutment and suprastructure. The experiment used 500 N of vertical force, applied in three different cases of axial load. Calculations of von Mises equivalent stresses of the tooth root and periodontium, implants and peri-implant tissue were made. For the model to which a non-resilient abutment is applied, maximum stress values in all three cases are observed in the cortical part of the bone (maximum stress value of 49.7 MPa). Measurements of stress and deformation in the bone tissue in the model with application of the resilientTSA abutment demonstrated similar distribution; however, these values are many times lower than in the model with non-resilient TSA abutment (maximum stress value of 28.9 MPa). Application of the resilient TSA abutment results in more equal distribution of stress and deformations in the bone tissue under vertical forces. These values are many times lower than in the model with the non-resilient abutment.

  10. Evaluation of hardness and colour change of soft liners after accelerated ageing.

    Science.gov (United States)

    Mancuso, Daniela Nardi; Goiato, Marcelo Coelho; Zuccolotti, Bruna Carolina Rossatti; Moreno, Amália; dos Santos, Daniela Micheline

    2009-07-01

    Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.

  11. The Use of Implants to Improve Removable Partial Denture Function.

    Science.gov (United States)

    Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A

    2014-12-01

    The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.

  12. The Effect of Food-Simulating Agents on the Bond Strength of Hard Chairside Reline Materials to Denture Base Resin.

    Science.gov (United States)

    Fatemi, Farzaneh Sadat; Vojdani, Mahroo; Khaledi, Amir Ali Reza

    2018-06-08

    To investigate the influence of food-simulating agents on the shear bond strength between direct hard liners and denture base acrylic resin. In addition, mode of failure was evaluated. One hundred fifty cylindrical columns of denture base resin were fabricated and bonded to three types of hard reline materials (Hard GC Reline, Tokuyama Rebase II Fast, TDV Cold Liner Rebase). Specimens of each reline material were divided into five groups (n = 10) to undergo 12-day immersion in distilled water, 0.02 N citric acid aqueous solution, heptane, and 40% ethanol/water solution at 37°C. The control group was not immersed in any solution. The shear bond strength test was performed, and the failure mode was determined. Statistics were analyzed with two-way ANOVA and chi-square test (α = 0.05). Significant interaction was found between the hard liners and food simulating agents (p < 0.001). The shear bond strength of Tokuyama in 40% ethanol and TDV in heptane decreased significantly (p = 0.001, p < 0.001 respectively); however, none of the solutions could significantly affect the shear bond strength of Hard GC Reline (p = 0.208). The mixed failure mode occurred more frequently in Hard GC Reline compared with the other liners (p < 0.001) and was predominant in specimens with higher bond strength values (p = 0.012). Food simulating agents did not adversely affect the shear bond strength of Hard GC Reline; however, ethanol and heptane decreased the bond strength of Tokuyama and TDV, respectively. These findings may provide support to dentists to recommend restricted consumption of some foods and beverages for patients who have to use dentures relined with certain hard liners. © 2018 by the American College of Prosthodontists.

  13. The effect of thermocycling on tensile bond strength of two soft liners.

    Science.gov (United States)

    Geramipanah, Farideh; Ghandari, Masoumeh; Zeighami, Somayeh

    2013-09-01

    Failure of soft liners depends mostly on separation from the denture base resin; therefore measurement of the bond strength is very important. The purpose of this study was to compare the tensile bond strength of two soft liners (Acropars, Molloplast-B) to denture base resin before and after thermocycling. Twenty specimens fromeach of the two different soft liners were processed according to the manufacturer's instructions between two polymethyl methacrylate (PMMA) sheets. Ten specimens in each group were maintained in 37°C water for 24 hours and 10 were thermocycled (5000 cycles) among baths of 5° and 55°C. The tensile bond strength was measured using a universal testing machine at a crosshead speed of 5 mm/min. Mode of failure was determined with SEM (magnification ×30). Two-way ANOVA was used to analyze the data. The mean and standard deviation of tensile bond strength of Acropars and Molloplast-B before thermocycling were 6.59±1.85 and1.51±0.22 MPa, respectively and 5.89±1.52 and1.37±0.18 MPa, respectively after thermocycling. There was no significant difference before and after thermocycling. Mode of failure in Acropars and Molloplast-B were adhesive and cohesive, respectivley. The bond strength of Acropars was significantly higher than Molloplast-B (P<0.05).

  14. Dynamics of heterogeneous liners with prolonged plasma creation

    International Nuclear Information System (INIS)

    Aleksandrov, V.V.; Branitskii, A.V.; Volkov, G.S.; Grabovskii, E.V.; Zurin, M.V.; Nedoseev, S.L.; Oleinik, G.M.; Samokhin, A.A.; Smirnov, V.P.; Fedulov, M.V.; Frolov, I.N.; Sasorov, P.V.

    2001-01-01

    Prolonged plasma creation in heterogeneous liners, in which the liner substance is separated into two phase states (a hot plasma and a cold skeleton), is investigated both experimentally and theoretically. This situation is typical of multiwire, foam, and even gas liners in high-current high-voltage facilities. The main mechanisms governing the rate at which the plasma is created are investigated, and the simplest estimates of the creation rate are presented. It is found that, during prolonged plasma creation, the electric current flows through the entire cross section of the produced plasma shell, whose thickness is comparable with the liner radius; in other words, a current skin layer does not form. During compression, such a shell is fairly stable because of its relatively high resilience. It is shown that, under certain conditions, even a thick plasma shell can be highly compressed toward the discharge axis. A simplified numerical simulation of the compression of a plasma shell in a liner with prolonged plasma creation is employed in order to determine the conditions for achieving regimes of fairly compact and relatively stable radial compression of the shell

  15. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  16. The Effect of Aloe vera Extract on Adherence of Candida albicans and Other Properties of Heat Cure Denture Soft Lining Material

    Directory of Open Access Journals (Sweden)

    Aseel Riyadh Abdulwahhab

    2018-03-01

    Full Text Available Objective: One of the serious drawbacks of denture soft lining materials is colonization by Candida albicans that might eventually leads to denture stomatitis. This can be treated either systemically or locally. With the recent increase interest in medicinal plants, this study aimed to evaluate the effect of Aloe vera powder incorporated with heat cure acrylic soft-liner powder on the adherence of Candida albicans, shear bond strength and tear strength. Methods: According to the results of pilot study, two percentages (3% and 10% of aloe vera powder was used. Candida adherence test, shear bond strength and tear strength tests were performed, also the long-term effect was evaluated after 2 and 4 weeks incubation in artificial saliva. All data was analyzed using SPSS software (version 24. Descriptive and inferential statistics, ANOVA test with post-hoc analysis was applied. Results: The results indicated that both concentrations of aloe vera showed a statistically highly significant decrease in Candida albicans cell count in comparison to control group, also a significant increase in shear bond strength and non-significant difference in tear strength of soft liner for the experimental groups. After 2 and 4 weeks incubation in artificial saliva, all experimental groups showed a statistically significant decrease in Candida albicans cell count and a statistically significant increase in shear bond strength and tear strength test. Conclusion: Incorporation of aloe vera powder with heat cure acrylic soft-liner powder helps to add an anti-candidal property to the soft liner, also this addition results in improvement in shear bond strength and tear strength.

  17. Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

    Science.gov (United States)

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-10-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated, but location of clasps may affect aesthetics. So, when patient is concerned about aesthetics, flexible partial dentures which is aesthetically superior to flipper and cast partial dentures, may be considered. But for the success of flexible removable partial denture, proper diagnosis, treatment planning and insertion technique of this prosthesis is very important, which have been thoroughly described in this article.

  18. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures

    Directory of Open Access Journals (Sweden)

    Bogna Stawarczyk

    2017-12-01

    Full Text Available The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x-, y- and z-axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the

  19. Flexible Thermoplastic Denture Base Materials for Aesthetical Removable Partial Denture Framework

    OpenAIRE

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-01-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated...

  20. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    Science.gov (United States)

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  1. The attitude of complete denture wearers towards denture adhesives in Istanbul

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; Arikan, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture

  2. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    Science.gov (United States)

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  3. The effect of denture stability, occlusion, oral hygiene and smoking on denture-induced stomatitis

    International Nuclear Information System (INIS)

    Nimri, Gadeer Mukatash

    2008-01-01

    This longitudinal clinical investigation was undertaken to find out the effect of denture wearing habit (day versus day and night), denture hygiene and cigarette smoking habit on the frequency of denture induced stomatitis. Comparisons were made between 240 complete denture wearers, half of whom were asked to wear their dentures at the daytime only and the other half to wear the denture day and night. All these participants were male patients with a mean age of 57.6 years who had received maxillary complete acrylic dentures for the first time. Fifty percent of the samples were smokers. A standard method for examination of the mouth and denture construction, insertion and follow up were employed. Putative risk factors (denture wearing habits, denture hygiene and smoking) were investigated. Subjects were recalled 12 months after insertion to examine the quality of the denture and the condition of the maxillary mucosa. No significant correlation was found between deterioration of stability or occlusion and type of habitual use of the dentures (P > 0.05). Fourteen percent of the cases reported with inflamed maxillary mucosa. Deterioration of retention or occlusion separately showed no correlation with the condition of the mucosa. However, associated deterioration of both stability and occlusion proved to be significantly correlated with the occurrence of denture stomatitis (P < 0.05). Denture stomatitis was significantly more frequently with subjects wearing their dentures overnight compared with those who removed them (P < 0.05). A significant correlation was also found between cigarette smoking, poor oral hygiene and the presence of denture induced stomatitis (P < 0.05). Nocturnal denture wearing habit, deficient oral and denture hygiene, and cigarette smoking are all important predisposing factors to denture-induced stomatitis, however, none of these factors was the sole cause of mucosal inflammation. (author)

  4. Denture adhesives improve mastication in denture wearers.

    Science.gov (United States)

    Gonçalves, Thais Marques Simek Vega; Viu, Flavia Carvalho; Gonçalves, Leticia Machado; Garcia, Renata Cunha Matheus Rodrigues

    2014-01-01

    This clinical trial evaluated the influence of denture adhesive (DA) use on masticatory function in denture wearers according to their denture-bearing ridge status. Thirty edentulous subjects, wearing new well-fitting dentures, were classified as having either a normal or resorbed ridge. Mastication was evaluated in patients who completed chewing tests with and without two DA substances (cream or strips), which were randomly assigned. A chewing test with a sieve method analyzed masticatory performance. A kinesiographic device evaluated chewing cycle, and a visual analog scale measured masticatory ability. Data were submitted to Mauchly's sphericity test, and PROC MIXED procedures were conducted on repeated measures. Tukey-Kramer tests performed appropriate statistical comparisons (P ≤ .05). DA use increased masticatory performance and ability in patients with both ridge types (P mastication by shortening the chewing cycle and by enhancing chewing ability and performance.

  5. The Split Denture: Managing Xerostomia in Denture Patients: A Case Report

    OpenAIRE

    Dabas, Nupur; Phukela, Sumit Singh; Yadav, Harish

    2011-01-01

    Wearing complete dentures can be an extremely uncomfortable experience for the people with Xerostomia. Various treatment modalities have been suggested in the literature to overcome the problem of xerostomia in complete denture patients. Incorporating reservoirs containing salivary substitutes, into dentures, is one of these treatment modalities. This paper presents case report of a patient suffering from xerostomia who was successfully treated with a new form of reservoir dentures. This new ...

  6. Effect of sealer coating and storage methods on the surface roughness of soft liners.

    Science.gov (United States)

    Usta Kutlu, Ilknur; Yanikoğlu, Nuran Dinckal; Kul, Esra; Duymuş, Zeynep Yesïl; Sağsöz, Nurdan Polat

    2016-03-01

    A soft lining is applied under a removable prosthesis for various reasons. The porosity of the lining material may increase colonization by microorganisms and cause tissue inflammation. The purpose of this in vitro study was to evaluate the effect of sealer coating on the surface roughness of soft lining materials under 4 different conditions. A total of 125 specimens were prepared. One high-temperature silicone-based soft lining material and 2 room-temperature-polymerized soft lining materials (1 silicone-based and 1 methacrylate-based) were used. Twenty-five specimens of each room-temperature soft lining material were coated with 2 layers of surface sealer. Additionally, 5 specimens of each material were stored in either distilled water, Coca-Cola, denture cleanser, saliva, or air. The surface roughness was measured at baseline and after 1, 7, 14, and 28 days. Surface roughness values were analyzed with repeated measures analysis of variance, and the Bonferroni multiple comparison test was performed using time-dependent groups and storage methods. In the time-dependent groups, methacrylate-based sealer-coated soft liners exhibited a significant increase in roughness (1.74-2.09 μm, P.05). Therefore, the sealer coating was not effective in reducing surface roughness. Among the time-dependent storage methods, the denture cleanser exhibited an almost significant increase in roughness (1.83-1.99 μm, P=.054). Coca-Cola and artificial saliva did not show a significant difference (P>.05). However, a significant decrease in roughness was found with distilled water (P=.02) and air (P<.001). Statistically significant differences in surface roughness were found among the different types of soft liners. The sealer coating had no significant effect, and denture cleanser slightly increased the surface roughness. Contrary to expectations, the roughness did not increase in all groups over time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry

  7. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    Science.gov (United States)

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Oral mucosal lesions in denture wearers.

    Science.gov (United States)

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  9. Evaluation of denture hygiene among removable denture wearers referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Molouk Torabi Parizi

    2013-06-01

    Full Text Available BACKGROUND AND AIM: The number of patients who need prosthetic treatments has increased. Efficient and regular procedures for cleaning removable dentures are important for maintaining good oral health. The aim of this study was to analyze the oral and prostheses care habits of removable denture users, who attended the clinics of Kerman, Iran. METHODS: This cross-sectional study was carried out on 350 patients, who attended the clinics of Kerman and were chosen by the multistage sampling method. Data were obtained from a checklist consisting of demographic characteristics (age, sex, educational level, kind of prosthesis, age of prosthesis, self-report of halitosis, and smoking status, denture hygiene habits, denture-wearing behavior, and cleanliness of denture by examiner. Data was analyzed using chi-squared test (P < 0.05. RESULTS: The mean age of patients was 58.52 ± 10.78 years, 103 (29.4% were male and 247 (70.6% were female. The results showed that 78.6% had complete denture and 12.7% reported halitosis, 55.1% used their denture at night, and 36.4% had poor denture hygiene. Brushing was the most used cleaning method by the patients (36.5%. 60.4% reported never having been instructed by their dentists as to how to clean their dentures. 58.6% had been using the same denture for more than 5 years. There was a significant correlation between the kind of denture, and denture hygiene and education level. CONCLUSION: According to the results of the present study denture hygiene was not favorable. Therefore, dentists should instruct the patients on cleaning their denture in order to prevent denture–induced lesions.

  10. Denture Adhesives

    Science.gov (United States)

    ... Devices Products and Medical Procedures Dental Devices Denture Adhesives Share Tweet Linkedin Pin it More sharing options ... Wearers Reporting Problems to the FDA Background Denture adhesives are pastes, powders or adhesive pads that may ...

  11. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  12. Effects of denture maintenance on satisfaction levels of Taiwanese elderly using removable partial dentures: a pilot study.

    Science.gov (United States)

    Wu, Ju-Hui; Yang, Yi-Hsin; Wang, Chau-Hsiang; Lee, Huey-Er; Du, Je-Kang

    2012-06-01

    The aim of this study was to evaluate the correlation between patient satisfaction with removable partial dentures and denture maintenance by patients, including regular application of denture adhesives and cleansers. The success of removable partial dentures depends on patient satisfaction with dentures and their regular denture maintenance. Demographic information, the Oral Impacts on Daily Performance (OIDP) indicator and details of denture maintenance (including the use of denture cleansers and adhesives) were collected from 193 (41.5% men and 58.5% women) participants by using questionnaires. A dentist performed oral examinations to evaluate denture function according to the OIDP items photographically and recorded the number of remaining teeth and Kennedy's classification. Most participants were satisfied with their removable partial dentures and tended to have higher satisfaction levels than the dentist's estimation. Further, those using denture adhesives and cleansers had higher satisfaction levels than those not using such denture maintenance. Appropriate education regarding denture use is important because regular denture maintenance by patients affects their degree of satisfaction with dentures, as well as the dentist's skill and the patient's oral condition. Dentists could use this information to predict the potential success of dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  13. Comprehensive review of geosynthetic clay liner and compacted clay liner

    Science.gov (United States)

    Shankar, M. Uma; Muthukumar, M.

    2017-11-01

    Human activity inevitably produces waste materials that must be managed. Some waste can be reused. However many wastes that cannot be used beneficially must be disposed of ensuring environmental safety. One of the common methods of disposal is landfilling. The most common problems of the landfill site are environmental degradation and groundwater contamination caused by leachate produced during the decomposition process of organic material and rainfall. Liner in a landfill is an important component which prevent leachate migration and prevent groundwater contamination. Earthen liners have been widely used to contain waste materials in landfill. Liners and covers for municipal and hazardous waste containment facilities are often constructed with the use of fine-grained, low plasticity soils. Because of low permeability geosynthetic clay liners and compacted clay liners are the main materials used in waste disposal landfills. This paper summaries the important geotechnical characteristics such as hydraulic conductivity, liquid limit and free swell index of geosynthetic clay liner and compacted clay liner based on research findings. This paper also compares geosynthetic clay liner and compacted clay liner based on certain criteria such as thickness, availability of materials, vulnerability to damage etc.

  14. Denture plaque--past and recent concerns.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  15. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    Directory of Open Access Journals (Sweden)

    Gray Janine C

    2012-08-01

    Full Text Available Abstract Background According to the UK Adult Dental Health Survey (2009 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone. Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period. Patients will then wear each set of dentures for a period of 8 weeks (in random order during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period. Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference and confirmation period (adjusted denture preference. A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300. Discussion

  16. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  17. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  18. Swallowed dentures: Two cases and a review

    Directory of Open Access Journals (Sweden)

    Mahir Gachabayov

    2015-12-01

    Conclusion: Fixed dentures can be accidentally ingested as well as removable dentures. Denture loosening leads to accidental denture ingestion. Patients with denture loosening should be recommended to visit dentist as soon as possible.

  19. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  20. A study to evaluate the location and frequency of denture-related ulcerations and postinsertion adjustments in complete denture patients

    Directory of Open Access Journals (Sweden)

    Saurabh Jain

    2017-01-01

    Full Text Available Background and Aims: Removable complete denture is one of the most common treatment modalities for completely edentulous patients. After denture insertion, patient very often faces problems with the denture even after complete care is taken during fabrication procedure. Most common complaint is traumatic ulcers. The present study aimed to locate the most common areas of ulcerations due to complete dentures, how frequently they occur and how many times patient visits for adjustment after insertion of complete denture. Materials and Methods: Two hundred and twenty-one patients were selected and were delivered complete dentures. Dentures were fabricated for all the patients. Each step of denture fabrication was controlled and guided by a prosthodontist. After placement of dentures, patients were evaluated at every recall visit and their dentures were adjusted. All the details of each visit (area of ulceration and number of visits were recorded in a self-designed format. Descriptive statistical analysis was done using SPSS version 13 software. Chi-squared test was used to evaluate the correlation between mucosal injuries and postinsertion day and the relationship between lesions, patient age, and patient gender. Results: All the 221 patients required denture adjustment due to mucosal injuries. No significant difference was found between denture-related injuries between males and females. Injuries related to mandibular dentures were significantly higher than those related to maxillary dentures. In mandible, the most common area of mucosal injury is posterior one-third of alveololingual sulcus; while in maxilla, the most common area of mucosal injury is labial frenum. Conclusion: Postinsertion adjustments are an important aspect of rehabilitating patient with complete dentures. Most of the denture-related injuries were in limiting areas. Proper border molding techniques, accurate secondary impressions, and use of pressure indicating paste during

  1. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    Science.gov (United States)

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  2. [Removable partial dentures. Oral functions and types

    OpenAIRE

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combinatio...

  3. Optimisation of energy absorbing liner for equestrian helmets. Part II: Functionally graded foam liner

    International Nuclear Information System (INIS)

    Cui, L.; Forero Rueda, M.A.; Gilchrist, M.D.

    2009-01-01

    The energy absorbing liner of safety helmets was optimised using finite element modelling. In this present paper, a functionally graded foam (FGF) liner was modelled, while keeping the average liner density the same as in a corresponding reference single uniform density liner model. Use of a functionally graded foam liner would eliminate issues regarding delamination and crack propagation between interfaces of different density layers which could arise in liners with discrete density variations. As in our companion Part I paper [Forero Rueda MA, Cui L, Gilchrist MD. Optimisation of energy absorbing liner for equestrian helmets. Part I: Layered foam liner. Mater Des [submitted for publication

  4. Denture quality has a minimal effect on health-related quality of life in patients with removable dentures.

    Science.gov (United States)

    Inoue, M; John, M T; Tsukasaki, H; Furuyama, C; Baba, K

    2011-11-01

    The present study examined the association of denture quality and health-related quality of life (HRQoL) in patients with removable dentures. In a study of 171 consecutive patients with removable partial dentures or complete dentures (mean age: 68·0 ± 9·3 years) at a university-based prosthodontic clinic, dentists rated two aspects of denture quality (stability and aesthetics) using a 100-mm visual analog scale (VAS). HRQoL was evaluated using the mental and physical component summary (MCS and PCS) scores of the Medical Outcomes Study Short-Form 36-Item Health Survey (SF-36). Oral health-related quality of life (OHRQoL) was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J). The associations among denture quality, OHRQoL, and HRQoL were examined by linear regression models. Bivariable linear regression analyses revealed that denture stability was significantly associated with the SF-36 MCS [regression coefficient = 0·52 for a 10-unit increase in denture stability on a 0-100 VAS, 95% confidence interval (CI): 0·03-1·00, P = 0·04], but not with the PCS (0·11, 95% CI: -0·49 to 0·70). Denture aesthetics was not related to the PCS or the MCS (0·22, 95% CI: -0·44 to 0·88 or 0·07, 95%CI: -0·47 to 0·62). When OHIP-J was added to the regression model, this variable was substantially and significantly associated with the MCS and PCS summary scores; in addition, the regression coefficient for denture quality decreased in magnitude and was statistically nonsignificant in all analyses. The quality of removable dentures had a minimal effect on HRQoL in patients with removable dentures, and this association was mediated by OHRQoL. © 2011 Blackwell Publishing Ltd.

  5. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    Science.gov (United States)

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  6. Denture Adhesives in Prosthodontics: An Overview.

    Science.gov (United States)

    Kumar, P Ranjith; Shajahan, P A; Mathew, Jyothis; Koruthu, Anil; Aravind, Prasad; Ahammed, M Fazeel

    2015-01-01

    The use of denture adhesives is common among denture wearers, and it is also prescribed by many dentists. Prescribing denture adhesives has been viewed by many prosthodontists as a means of compensating for any defects in the fabrication procedures. Denture adhesives add to the retention and thereby improve chewing ability, reduce any instability, provide comfort and eliminate the accumulation of food debris beneath the dentures. Consequently, they increase the patient's sense of security and satisfaction. However, obtaining the advice of the dental practitioner prior to the use of adhesives is a must.

  7. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  8. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    Science.gov (United States)

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  9. Experimental evaluation of cell liners

    International Nuclear Information System (INIS)

    Wierman, R.W.; Simmons, L.D.; Muhlestein, L.D.

    Cell liners may be used in breeder reactor sodium pipe ways, sodium cells, and lower cavity region to provide a leak-tight cell and to protect the concrete from sodium in the unlikely event of a sodium spill. The objectives of the HEDL liner verification test program are to evaluate the integrity of liner concepts under postulated accident conditions and to develop the experimental data base which will demonstrate that liners will not fail. Two specific tests are reported; a high temperature liner feature test, and a large-scale liner sodium spill test. In both tests no failures of the liners or tendencies toward failure were detected. The discussed liner designs appeared to be conservative, and the liner strength appeared to be more than adequate

  10. A modified technique for retention of orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  11. Denture adhesives: a systematic review.

    Science.gov (United States)

    Papadiochou, Sofia; Emmanouil, Ioannis; Papadiochos, Ioannis

    2015-05-01

    Denture adhesives have been the objective of scientific research for over half a century. Although they are used by denture wearers worldwide, investigations of their effectiveness and biocompatibility have led to controversial conclusions. The purpose of this study was to review the literature data with regard to the effectiveness and biocompatibility of denture adhesives as well as the attitudes of both patients and dental professionals toward these materials. An electronic search of English peer-reviewed dental literature in the Medline database was conducted to evaluate the effectiveness and biocompatibility of denture adhesives. There was no limitation in publication year, so the search included all the available scientific evidence included in that particular database until March 2014. Specific inclusion criteria were used for the selection of the appropriate articles. A manual search of the citations of the obtained articles followed to extend the electronic search. A full text review was carried out for only 32 articles. Of the 32 articles, 21 examined the efficacy of denture adhesives in terms of retention and stability and masticatory performance, 6 evaluated the issue of the biocompatibility of denture adhesives, and 5 presented the attitudes of either professionals or patients toward these materials. The majority of clinical studies supported the fact that denture adhesives enhance the retention, stability, and masticatory performance of a removable prosthesis. In terms of biocompatibility, long-term in vivo studies to investigate potential harmful effects were lacking. Patients are satisfied with denture adhesives that meet their needs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution.

    Science.gov (United States)

    Sato, Maki; Suzuki, Yasunori; Kurihara, Daisuke; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2013-04-01

    This study explored the relationship between implant support and the denture-supporting area by comparing the stability of an implant-supported distal extension removable partial denture and a conventional distal extension removable partial denture. A model simulating a mandibular bilateral distal extension missing (#34-37 and #44-47) was fabricated using silicone impression material as soft tissue (2 mm thick) on an epoxy resin bone model. The denture base was reduced by 5 mm cutting part of both the retromolar pad and the lingual border. Loads of up to 5 kg were applied, and the pressure and displacement of the RPDs were simultaneously measured and analyzed using the Wilcoxon test (αremovable partial denture (ISRPD) was significantly less than on the conventional RPD (CRPD). As the supporting area of the denture base decreased, the pressure and the denture displacement of the CRPD were greater than for the ISRPD. This study indicated that implant placement at the distal edentulous ridge can prevent denture displacement of the distal extension bases, regardless of the supporting area of the denture base. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    NARCIS (Netherlands)

    Polyzois, G.L.; Baat, C. de

    2012-01-01

    OBJECTIVE: To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. BACKGROUND: There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. MATERIALS AND METHODS:

  14. Efficacy of Denture Cleansers in Reducing Microbial Counts from Removable Partial Dentures: A Short-Term Clinical Evaluation

    OpenAIRE

    Lucena-Ferreira,Silvia Carneiro de; Cavalcanti,Indira Moraes Gomes; Cury,Altair Antoninha Del Bel

    2013-01-01

    This clinical study investigated if daily immersion in denture cleansers reduces microbial counts on removable partial denture's (RPD) biofilm. Twenty-five RPD wearer volunteers were selected and instructed to complement the hygiene of their dentures by immersing them in an enzymatic peroxide-based denture cleanser (Polident® 3 minute) once a day for 3 min for a period of 15 days. The biofilm was collected from RPD surfaces with a swab immediately before (baseline) and after the experimental ...

  15. Simulation of LOCA and ageing effect with containment liner mockup for analysis of liner-concrete interaction

    International Nuclear Information System (INIS)

    Wienand, B.; Fila, A.; Hermann, N.; Mueller, M.

    2015-01-01

    The investigation of the pre-stressed concrete wall behavior including the liner during LOCA conditions is important for the assessment of the structural integrity of the structure and the leak tightness of the liner. In the frame of the NUGENIA ACCEPPT project WP1 G4 'Structural interaction of liner with the concrete', a load test on a reactor containment liner mockup was carried out. The pre-stressed mockup represents a cylindrical part of the liner, embedded in the concrete wall, but without the wall curvature which is not test relevant. It correlates in material and geometrical properties to the EPR containment. The purpose of the test was to check the liners structural behavior and its integrity for Loss of Coolant Accident (LOCA) load combination considering pre-stressing forces and ageing effects due to creep and shrinkage including liner buckling. The test was carried out at the Karlsruhe Institute of Technology (KIT) in September 2013. This article presents the measurement technology, the results and the development of a calculation method for the embedded liner structure. It appears that the liner deformation results are exemplarily shown at the locations of the imperfections, where the liner buckling is anticipated. The measured liner surface strains ranged between +2 and -10 per thousand. The compressive strains are higher than the tensile strains due to the compressive membrane strains caused by pre-stressing and heating. Although the liner got plastic deformations, the liner strains are still far below the elongation at rupture, which indicates that the liner integrity is ensured. We can conclude that the liner mockup test proceeded as planned. The evaluation results show that the purpose of the liner mockup to simulate LOCA + ageing conditions and liner buckling has fully been achieved

  16. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  17. Efficacy of commercial and household denture cleansers against Candida albicans adherent to acrylic denture base resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    M Nanditha Kumar

    2012-01-01

    Conclusion: Within the limitations of this in vitro study, denture cleansers were found to be effective in reducing C albicans cells adhering to dentures. The commercial denture cleansers (Fittydent® and Clinsodent® were more effective than household denture cleansers (vinegar and diluted vinegar.

  18. [Functional load distribution in cases of different types of removable dentures fastening].

    Science.gov (United States)

    Zhulev, E N; Klokov, A A

    2007-01-01

    Questions of studying of a biomechanics of system prosthesis - prosthetic region using of mathematical modelling are surveyed. The original way of definition of physical parameters of a mucosa of an edentulous alveolar process is offered. Modelling of a leaky adhering of prosthesis basis to a mucosa as free saddle situation shows, that a abutment teeth and an edentulous alveolar part of a jaw are in an optimum situation at sliding resilient fastening of a removable partial denture. Rigid bond in the given situation on the contrary promotes development of an overload of abutment teeth and their inclination distally.

  19. The effectiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures

    Directory of Open Access Journals (Sweden)

    Patrícia Costa Cruz

    2011-12-01

    Full Text Available Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth. OBJECTIVE: This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets, mechanical (ultrasonic and combined (association of the effervescent and ultrasonic methods. MATERIAL AND METHODS: Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20: (1 Brushing with water (Control; (2 Effervescent tablets (Corega Tabs; (3 Ultrasonic device (Ultrasonic Cleaner, model 2840 D; (4 Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm quantified (Image Tool 2.02. The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture. RESULTS: The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; P<0.001, the mean ranks for the treatments and results for Dunn multiple comparison test were: Control (60.9; Chemical (37.2; Mechanical (35.2 and Combined (29.1. CONCLUSION: The experimental methods were equally effective regarding the ability to remove biofilm and were superior to the control method (brushing with water. Immersion in alkaline peroxide and ultrasonic vibration can be used as auxiliary agents

  20. Liner mounting assembly

    Science.gov (United States)

    Halila, Ely E. (Inventor)

    1994-01-01

    A mounting assembly includes an annular supporting flange disposed coaxially about a centerline axis which has a plurality of circumferentially spaced apart supporting holes therethrough. An annular liner is disposed coaxially with the supporting flange and includes a plurality of circumferentially spaced apart mounting holes aligned with respective ones of the supporting holes. Each of a plurality of mounting pins includes a proximal end fixedly joined to the supporting flange through a respective one of the supporting holes, and a distal end disposed through a respective one of the liner mounting holes for supporting the liner to the supporting flange while unrestrained differential thermal movement of the liner relative to the supporting flange.

  1. Development of liner cutting method for stainless steel liner

    International Nuclear Information System (INIS)

    Takahata, Masato; Wignarajah, Sivakmaran; Kamata, Hirofumi

    2005-01-01

    The present work is an attempt to develop a laser cutting method for cutting and removing stainless steel liners from concrete walls and floors in cells and fuel storage pools of nuclear facilities. The effects of basic laser cutting parameters such as cutting speed, assist gas flow etc. were first studied applying a 1 kW Nd:YAG laser to mock up concrete specimens lined with 3 mm thick stainless steel sheets. These initial studies were followed by studies on the effect of unevenness of the liner surface and on methods of confining contamination during the cutting process. The results showed that laser cutting is superior to other conventional cutting methods from the point of view of safety from radioactivity and work efficiency when cutting contaminated stainless steel liners. In addition to the above results, this paper describes the design outline of a laser cutting system for cutting stainless liners at site and evaluates its merit and cost performance. (author)

  2. Denture hygiene knowledge and practice amongst patients in a ...

    African Journals Online (AJOL)

    Aim: To assess patients' knowledge on denture hygiene and the hygiene methods used for cleaning removable partial dentures. Methods: This was a ... Other information obtained were the duration of denture use, frequency of denture cleaning and type of material used for denture cleaning. Results: The age of the ...

  3. Sanitary landfill liners

    DEFF Research Database (Denmark)

    Christiansen, Ole V.; Stentsøe, Steen; Petersen, Søren

    DS/INF 466 is the revised Danish recommendation for investigations, design and construction of landfill liners.......DS/INF 466 is the revised Danish recommendation for investigations, design and construction of landfill liners....

  4. [Removable partial dentures. Oral functions and types

    NARCIS (Netherlands)

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic

  5. Clinical application of removable partial dentures using thermoplastic resin-part I: definition and indication of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-Ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-01-01

    This position paper proposes a definition and naming standard for removable partial dentures (RPDs) using thermoplastic resin, and presents a guideline for clinical application. A panel of 14 experts having broad experience with clinical application of RPDs using thermoplastic resin was selected from members of the Japan Prosthodontic Society. At a meeting of the panel, "non-metal clasp denture" was referred as the generic name of RPDs with retentive elements (resin clasps) made of thermoplastic resin. The panel classified non-metal clasp dentures into two types: one with a flexible structure that lacks a metal framework and the other having a rigid structure that includes a metal framework. According to current prosthetic principles, flexible non-metal clasp dentures are not recommended as definitive dentures, except for limited cases such as patients with a metal allergy. Rigid non-metal clasp dentures are recommended in cases where patients will not accept metal clasps for esthetic reasons. Non-metal clasp dentures should follow the same design principles as conventional RPDs using metal clasps. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. [Influence of attachment type on stress distribution of implant-supported removable partial dentures].

    Science.gov (United States)

    Yang, Xue; Rong, Qi-guo; Yang, Ya-dong

    2015-02-18

    To compare influences of different retention attachments on stress among supporting structures. By 3-dimensional laser scanner and reverse engineering computer aided design (CAD) software, a basic partially edentulous digital model with mandibular premolar and molar missing was established. Implant attachment and removable partial dentures (RPD) were added into the basic model to build three kinds of models: RPD only, RPD + implant + Locator attachment, and RPD + implant + Magfit attachment. Vertical and inclined loads were put on artificial teeth unilaterally. By means of 3-dimensional finite element analysis, the stress distribution and displacement of the main supportive structures were compared. A complete 3-dimensional finite element model was established, which contained tooth structure, and periodontal structures. The displacement of the denture was smaller in Locator (9.38 μm vertically, 45.48 μm obliquely) and Magfit models (9.54 μm vertically, 39.45 μm obliquely) compared with non-implant RPD model (95.27 μm vertically, 155.70 μm obliquely). Compared with the two different attachments, cortical bone stress value was higher in Locator model (Locator model 10.850 MPa vertically, 43.760 MPa obliquely; Magfit model 7.100 MPa vertically, 19.260 MPa obliquely).The stress value of abutment periodontal ligamentin Magfit model (0.420 MPa vertically) was lower than that in Locator model (0.520 MPa vertically). The existence of implant could reduce maximum von Mises value of each supportive structure when Kennedy I partially edentulous mandible was restored. Comparing the structure of Magfit and Locator attachment, the contact of Magfit attachment was rigid, while Locator was resilient. Locator attachment could improve stability of the denture dramatically. Locator had stronger effect on defending horizontal movement of the denture.

  7. Dental health professional recommendation and consumer habits in denture cleansing.

    Science.gov (United States)

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less

  8. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  9. Composite liners protect ground water

    Energy Technology Data Exchange (ETDEWEB)

    Tatzky, R; August, H

    1987-12-01

    For about 10 years flexible membrane liners (FMLs) have been used as bottom liners to protect ground water in the vicinity of waste sites. But a permeation (absorption, diffusion, desorption) of chemical liquids, e.g. hydrocarbons (HC) and chlorinated hydrocarbons (CHC) will generally occur. The rates of permeation depend, first of all, on the chemical affinity, the thickness of the FML and the boundary conditions. In order to improve the barrier quality of polymeric membranes, it is necessary to study the transport processes of HC and CHC through the polymeric materials. Long-term tests with composite liners are additionally carried out. These are liners which consist of two components, flexible membrane and natural soil liner (recompacted clay, bentonite-soil mixtures). Laboratory studies show that with composite liners a perfect sealing of waste sites may be possible. Test methods for measuring permeation rates of HC and CHC through polymeric membranes and methods of testing for the development of composite liner systems are presented. (orig.)

  10. Fracture-dissociation of ceramic liner.

    Science.gov (United States)

    Hwang, Sung Kwan; Oh, Jin-Rok; Her, Man Seung; Shim, Young Jun; Cho, Tae Yeun; Kwon, Sung Min

    2008-08-01

    The use of BIOLOX delta ceramic (CeramTec AG, Plochingen, Germany) has been increasing. This ceramic prevents cracking by restraining the phase transformation due to the insertion of nano-sized, yttria-stabilized tetragonal zirconia into the alumina matrix. This restrains the progress of cracking through the formation of platelet-like crystal or whiskers due to the addition of an oxide additive. We observed a case of BIOLOX delta ceramic liner (CeramTec AG) rim fracture 4 months postoperatively. Radiographs showed that the ceramic liner was subluxated from the acetabular cup. Scratches on the acetabular cup and femoral neck were seen, and the fracture was visible on the rim of the liner. Under electron microscope, metal particle coatings from the ceramic liner were identified. The ceramic liner, fracture fragments, and adjacent tissues were removed and replaced with a ceramic liner and femoral head of the same size and design. We believe the mechanism of the fracture-dissociation of the ceramic liner in this case is similar to a case of separation of the ceramic liner from the polyethylene shell in a sandwich-type ceramic-ceramic joint. To prevent ceramic liner fracture-dissociation, the diameter of the femoral neck needs to be decreased in a new design, while the diameter of the femoral head needs to be increased to ensure an increase in range of motion.

  11. The Effect of Two Types of Denture Adhesive on the Satisfaction Parameters of Complete Denture Wearers

    Directory of Open Access Journals (Sweden)

    Farzin M

    2017-09-01

    Full Text Available Statement of Problem: Patient satisfaction is highly influenced by the retention of the denture. In some instances using denture adhesives may help the patient to achieve this goal. Objectives: The purpose of this study was to evaluate the participants’ ’opinion concerning the effectiveness of two types of denture adhesives having the same composition (Fixative-powder, Protefix-cream. Materials and Methods: Forty healthy patients (25 Males and 15 Fe-males who visited the Department of Prosthodontics of Shiraz Dentistry School were selected. The oral cavity was examined and patients with oral ulcers, history of allergic reaction, severe xerostomia, red, white and/or red and white lesions were excluded. The subjects were instructed to receive a sequence of treatment protocols. All patients applied Fixative-powder on the dentures for seven days. The Participants were asked to fill a question-naire to include their opinion regarding the strength, biocompatibility, convenience and masticatory ability of the adhesive. On the next seven days, the patients were asked not to use the adhesives and they completed the same questionnaire again. Finally, all participants were asked to apply Protefix-cream on their dentures for a week followed by no cream applica-tion for another 7 days. These patients answered the same questionnaire and data were collected and analyzed using paired-samples t-test and Chi-square test. Result: Denture adhesives significantly improved the overall satisfaction level of the patients (p =0.01. When testing the fixative powder, the satis-faction score of the participants during the first week (powder application and the 2nd weak (no application was 19.95±3.76 and 26.2±2.82, respec-tively. The overall satisfaction rate of the patients using the Protefix adhe-sive was 19.35±5.48 in the third week (adhesive application and 25.85± 4.35 in the fourth week (no application. Conclusions: The study clarified that applying denture

  12. Removable denture-related oral mucosal lesions: descriptive clinical study

    Directory of Open Access Journals (Sweden)

    Gökçen Akçiçek

    2017-05-01

    Full Text Available Objective: The aim of this study was to investigate whether there was a relationship between removable denture-related oral mucosal lesions and denture type, and demographic characteristics. Materials and Method: The age, sex, denture type, systemic condition and medication use, presence of denture-related oral mucosal lesions (DROML, their locations and patients’ awareness of above mentioned lesions were recorded for 199 patients. Pearson chi-square test was used to analyse the relationship between the DROML and denture type, and demographic characteristics of the patients. Results: Among the patients included to the study, 122 (61.3% were female and 77 (38.7% were male. Ninety-six patients (48.2% exhibited DROML, whereas 103 patients (51.8% had no DROML. No relationship was detected between DROML and age, and sex (p>0.05. The most commonly detected DROML was denture stomatitis (34.7%. Denture stomatitis was significantly more frequently seen in partial denture wearers (p<0.05, while epulis fissuratum and flabby ridge were statistically more frequent in complete denture wearers (p<0.001. Traumatic ulcer was more frequently found in mandibular complete denture wearers (p<0.05, while epulis fissuratum and flabby ridge were significantly more common in maxillary complete denture wearers (p<0.001. Among the patients with DROML, 57.3% stated that they were unaware of these lesions. Conclusion: In this study sample, the rate of DROML was high in patients wearing removable dentures (48.2%, and more than half of the patients with DROML were not aware of these lesions. Upon these findings, it is considered that removable denture wearers should follow the denture usage instructions and should be informed about the importance of periodic controls.

  13. Complication rates and patient satisfaction with removable dentures

    Science.gov (United States)

    Bilhan, Hakan; Erdogan, Ozge; Ergin, Selen; Celik, Melahat; Ates, Gokcen

    2012-01-01

    PURPOSE The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of Pdentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations (Pdentures with wrong centric relations caused need for addition of artificial teeth. PMID:22737317

  14. A follow-up study on removable partial dentures in undergraduate program: part I. participants and denture use by telephone survey.

    Science.gov (United States)

    Yoshida, Eiko; Fueki, Kenji; Igarashi, Yoshimasa

    2011-07-04

    The aim of this study was to investigate the clinical outcome of removable partial dentures (RPDs) designed to minimize denture mobility during function. Using archived files of the undergraduate program between 2003 and 2005 at Tokyo Medical and Dental University, a list of 169 patients treated with 184 RPDs was created. The RPDs had either an acrylic resin-base or a cobalt-chrome framework-base. Two examiners telephoned all the listed patients and interviewed 118 patients (70%) regarding the use of their RPDs. Of 118 patients, 42 (36%) had stopped using, mainly due to problems with abutment teeth in resin-based dentures, and replacement in cobalt-chrome-based dentures. There was no significant difference in mean age, gender distribution, mean number of remaining/abutment teeth, distribution of denture arch, and Kennedy classification between denture use and nonuse groups (p>0.05). The nonuse group showed a significantly higher percentage of resin-base compared to the use group (p = 0.006). Logistic regression analysis indicated that resin-base was a significant risk factor for nonuse (p = 0.008). The present findings suggest that abutment teeth should be selected carefully, especially in this type of resin-based RPDs, and that the denture base material may be a critical factor which determines denture use.

  15. Denture-related oral mucosal lesions among removable denture wearers ‎referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Shahrzad Taheri

    2016-05-01

    CONCLUSION: The finding of this study showed the prevalence of denture-related mucosal lesions is common. Dentists should be instruct the patients for removing the denture at night and routine follow-up visits.

  16. [Study on retention and stability of linear occlusal complete dentures].

    Science.gov (United States)

    Zhang, Ping; Xu, Jun

    2003-01-01

    To learn retention and stability of linear occlusal complete dentures by investigating the subjective feelings of patient and the value of retention force. Static retention forces of maxillary and mandibular dentures were measured for 25 patients wearing linear occlusal dentures by using Hz-1 retention dynamometer. The subjective feelings of patients in functional state were gained simultaneously through questionnaire. Linear occlusal dentures demonstrate good retention in static and dynamic state. Among patients with severe resorption of residual ridge (RRR), mandibular linear occlusal dentures (shown good retentive subjective feelings) demonstrate significantly smaller retention force than those with slight or medium degree of RRR. There is no correlation between the subjective feelings and the values of retention forces of mandibular dentures. The subjective feelings of patients wearing new linear occlusal dentures are much better than that of old anatomic occlusal dentures. Linear occlusal dentures improve the performances of dentures by enhancing their stability during mastication movement.

  17. Quantitative Estimation of Yeast on Maxillary Denture in Patients with Denture Stomatitis and the Effect of Chlorhexidine Gluconate in Reduction of Yeast

    Directory of Open Access Journals (Sweden)

    Jaykumar R Gade

    2011-01-01

    Full Text Available Denture stomatitis is a condition associated with wearing of a denture. The predisposing factor leading to denture stomatitis could be poor oral hygiene, ill-fitting denture and relief areas. Around 30 patients with denture stomatitis were advised to rinse with chlorhexidine gluconate mouthwash for 14 days and were directed to immerse the upper denture in the chlorhexidine solution for 8 hours. The samples were collected by scraping maxillary denture in saline at three intervals, prior to, at the end of 24 hours and after 14 days of treatment, then were inoculated and quantitative estimation of the yeast growth on Sabouraud′s dextrose agar plate was done. It was observed that after a period of 14 days, there was a reduction in the growth of yeast and also improvement in the clinical picture of the oral mucosa

  18. Localized deformation of zirconium-liner tube

    International Nuclear Information System (INIS)

    Nagase, Fumihisa; Uchida, Masaaki

    1988-03-01

    Zirconium-liner tube has come to be used in BWR. Zirconium liner mitigates the localized stress produced by the pellet-cladding interaction (PCI). In this study, simulating the ridging, stresses were applied to the inner surfaces of zirconium-liner tubes and Zircaloy-2 tubes, and, to investigate the mechanism and the extent of the effect, the behavior of zirconium liner was examined. As the result of examination, stress was concentrated especially at the edge of the deformed region, where zirconium liner was highly deformed. Even after high stress was applied, the deformation of Zircaloy part was small, since almost the concentrated stress was mitigated by the deformation of zirconium liner. In addition, stress and strain distributions in the cross section of specimen were calculated with a computer code FEMAXI-III. The results also showed that zirconium liner mitigated the localized stress in Zircaloy, although the affected zone was restricted to the region near the boundary between zirconium liner and Zircaloy. (author)

  19. Liner used in tailings ponds

    International Nuclear Information System (INIS)

    Dinchak, W.G.

    1984-01-01

    A composite liner has been developed for use in hazardous waste impoundments and in tailings ponds where uranium is involved. The liner offers a high degree of reliability against seepage, is durable, and provides a firm working surface. The advantages of the liner are discussed

  20. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study.

    Science.gov (United States)

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S

    2015-08-01

    The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.

  1. In vitro comparison of the tensile bond strength of denture adhesives on denture bases.

    Science.gov (United States)

    Kore, Doris R; Kattadiyil, Mathew T; Hall, Dan B; Bahjri, Khaled

    2013-12-01

    With several denture adhesives available, it is important for dentists to make appropriate patient recommendations. The purpose of this study was to evaluate the tensile bond strength of denture adhesives on denture base materials at time intervals of up to 24 hours. Fixodent, Super Poligrip, Effergrip, and SeaBond denture adhesives were tested with 3 denture base materials: 2 heat-polymerized (Lucitone 199 and SR Ivocap) and 1 visible-light-polymerized (shade-stable Eclipse). Artificial saliva with mucin was used as a control. Tensile bond strength was tested in accordance with American Dental Association specifications at 5 minutes, 3 hours, 6 hours, 12 hours, and 24 hours after applying the adhesive. Maximum forces before failure were recorded in megapascals (MPa), and the data were subjected to a 2-way analysis of variance (α=.05). All 4 adhesives had greater tensile bond strength than the control. Fixodent, Super Poligrip, and SeaBond had higher tensile bond strength values than Effergrip. All adhesives had the greatest tensile bond strength at 5 minutes and the least at 24 hours. The 3 denture bases produced significantly different results with each adhesive (Padhesives had the greatest tensile bond strength, followed by Ivocap and Eclipse. All 4 adhesives had greater tensile bond strength than the control, and all 4 adhesives were strongest at the 5-minute interval. On all 3 types of denture bases, Effergrip produced significantly lower tensile bond strength, and Fixodent, Super Poligrip, and SeaBond produced significantly higher tensile bond strength. At 24 hours, the adhesive-base combinations with the highest tensile bond strength were Fixodent on Lucitone 199, Fixodent on Eclipse, Fixodent on Ivocap, and Super Poligrip on Ivocap. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  2. Acoustic Liners for Turbine Engines

    Science.gov (United States)

    Jones, Michael G (Inventor); Grady, Joseph E (Inventor); Kiser, James D. (Inventor); Miller, Christopher (Inventor); Heidmann, James D. (Inventor)

    2016-01-01

    An improved acoustic liner for turbine engines is disclosed. The acoustic liner may include a straight cell section including a plurality of cells with straight chambers. The acoustic liner may also include a bent cell section including one or more cells that are bent to extend chamber length without increasing the overall height of the acoustic liner by the entire chamber length. In some cases, holes are placed between cell chambers in addition to bending the cells, or instead of bending the cells.

  3. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  4. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method

    Directory of Open Access Journals (Sweden)

    Radović Katarina

    2010-01-01

    Full Text Available Introduction. Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral freeend saddle denture without major connector was taken into consideration. Objective. The aim was to analyze and compare a unilateral RPD (removable partial denture and a classical RPD by calculating and analyzing stresses under different loads. Methods. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made. The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. Results. The Fault Model Extractor (FME analysis and calculation showed the complete behavior of unilateral removable partial denture and abutments (canine and first premolar, as well as the behavior of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Conclusion. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values.

  5. Preparations to ship EPICOR liners

    International Nuclear Information System (INIS)

    Queen, S.P.

    1983-06-01

    The sampling and analysis of the hydrogen rich atmosphere of the 49 EPICOR II ion-exchange prefilter liners generated in the decontamination of radioactive water at TMI-2 will provide data to ensure safe storage and shipment of highly loaded ion-exchange media. This report discusses the prototype gas sampling tool used to breech the containment of the liners, the tool support equipment for sampling and inerting the liners, and the characterization program used for determining the radiolytic hydrogen generation rates in the liners

  6. Plasma-driven liners

    International Nuclear Information System (INIS)

    Kilic, H.; Linhart, J.G.; Bortolotti, A.; Nardi, V.

    1992-01-01

    The deposition of thermal energy by laser or ion beams in an ablator is capable of producing a very large acceleration of the adjacent pusher - for power densities of 100 Terrawatts/cm 2 , ablator pressure in the range of 10 Mbar is attainable. In the case of a plasma drive such driving pressures and accelerations are not directly possible. When a snowplough (SP) is used to accelerate a thin liner, the driving pressure is that of the magnetic piston pushing the SP, i.e. at most 0.1 Mbar. However, the initial radius r 0 of the liner can be a few centimeters, instead of 1 (mm) as in the case in direct pellet implosions. In order to compete with the performance of the beam-driven liners, the plasma drive must demonstrate that a) thin liner retains a high density during the implosion (lasting a fraction of a μsec); b) radial compression ratio r 0 /r min of the order of 100 can be attained. It is also attractive to consider the staging of two or more liners in order to get sharpening and amplifications of the pressure and/or radiation pulse. If a) and b) are verified then the final pressures produced will be comparable with those of the beam-driven implosions. (author) 5 refs., 3 figs

  7. 21 CFR 872.3580 - Preformed gold denture tooth.

    Science.gov (United States)

    2010-04-01

    ... tooth in a fixed or removable partial denture. (b) Classification. Class I (general controls). The... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a...

  8. Controlling fungal biofilms with functional drug delivery denture biomaterials.

    Science.gov (United States)

    Wen, Jianchuan; Jiang, Fuguang; Yeh, Chih-Ko; Sun, Yuyu

    2016-04-01

    Candida-associated denture stomatitis (CADS), caused by colonization and biofilm-formation of Candida species on denture surfaces, is a significant clinical concern. We show here that modification of conventional denture materials with functional groups can significantly increase drug binding capacity and control drug release rate of the resulting denture materials for potentially managing CADS. In our approach, poly(methyl methacrylate) (PMMA)-based denture resins were surface grafted with three kinds of polymers, poly(1-vinyl-2-pyrrolidinone) (PNVP), poly(methacrylic acid) (PMAA), and poly(2-hydroxyethyl methacrylate) (PHEMA), through plasma-initiated grafting polymerization. With a grafting yield as low as 2 wt%, the three classes of new functionalized denture materials showed significantly higher drug binding capacities toward miconazole, a widely used antifungal drug, than the original PMMA denture resin control, leading to sustained drug release and potent biofilm-controlling effects against Candida. Among the three classes of functionalized denture materials, PNVP-grafted resin provided the highest miconazole binding capability and the most powerful antifungal and biofilm-controlling activities. Drug binding mechanisms were studied. These results demonstrated the importance of specific interactions between drug molecules and functional groups on biomaterials, shedding lights on future design of CADS-managing denture materials and other related devices for controlled drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Candida albicans importance to denture wearers. A literature review.

    Science.gov (United States)

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  10. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    Science.gov (United States)

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  11. Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis.

    Science.gov (United States)

    Memari, Yeganeh; Geramy, Allahyar; Fayaz, Amir; Rezvani Habib Abadi, Shirin; Mansouri, Yasaman

    2014-09-01

    Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stress distribution, in distal extension implant assisted removable partial dentures. Three-dimensional models of a bilateral distal extension partially edentulous mandible containing anterior teeth and first premolar in both sides of the arch, a partial removable denture and an implant (4×10mm) were designed. With the aid of the finite element program ANSYS 8.0, the models were meshed and strictly vertical forces of 10 N were applied to each cusp tip. Displacement and von Mises Maps were plotted for visualization of results. When an implant was placed in the second premolar region, the highest stress on implant, abutment tooth and cancellous bone was shown. The lowest stress was shown on implant and bone in the 1(st) molar area. Implants located in the first molar area showed the least distribution of stresses in the analyzed models.

  12. Effect of microwave cured acrylic resin on candidal growth in complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on candidal growth . Seven completely edentulous male patients with on history of denture wearing participated in this study. all the selected patients were re-habilitated by mucosa supported complete dentures .The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. one month resting period was allowed so as candidal count can reach to normal, then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique.

  13. Clinical evaluation of failures in removable partial dentures.

    Science.gov (United States)

    Jorge, Janaina H; Quishida, Cristiane C C; Vergani, Carlos E; Machado, Ana L; Pavarina, Ana C; Giampaolo, Eunice T

    2012-01-01

    The aim of this clinical study was to evaluate the effects of removable partial dentures on the support tissues and changes occurring in lower tooth-supported and bilateral distal-extension dentures, 5 years after placement. The study involved analysis of a total of 53 patients who received prosthetic treatment for removable partial dentures. The patients were divided into two groups. In group 1, the patients had a completely edentulous maxilla and an edentulous area with natural teeth remaining in both the anterior and posterior regions. In group 2, the patients had a completely edentulous maxilla and partially edentulous mandible with preserved anterior teeth. Tooth mobility, prevalence of caries, fracture of the abutment teeth, fracture and/or deformation of the removable partial denture components and stability of the denture base were evaluated. The use of a removable partial denture increased tooth mobility, reduced the prevalence of caries, and did not cause loss or fracture of the abutments or damage to their components, when compared with the baseline. It was concluded that there was no difference between the groups as evaluated in terms of tooth mobility, prevalence of caries, loss and fracture of the abutments or damage to the components of the removable partial denture.

  14. Design of steel-liners and their anchorage with regard to non-linear behaviour of liner-material and anchorage

    International Nuclear Information System (INIS)

    Oberpichler, R.

    1979-01-01

    The thin steel liner attached by studs or rib-type anchors to the interior wall of a Prestressed Concrete Reactor Pressure Vessel (PCRV) or a Concrete Containment Vessel (PCCV) has to provide the leak-tightness of the vessel. The liner also may serve as internal shuttering for placing concrete as well as a support for the cooling system or thermal isolation. Mainly strained by self-limited loads imposed on the liner by deformations of the vessel-wall or by heatup inside the vessel the liner predominantly will function in a compressive biaxially strained state like a membrane. The vessel-wall is assumed to be a rigid boundary without reactions caused by the liner-anchor-restraints. Furthermore it is assumed that the liner supported in a close-spaced pattern to the concrete with respect to self-limited loads and all effects of non-linear behaviour of liner-material and non-linear anchor-characteristics will not fail by instability, especially not by an effect of snapthrough. Only one essential mode of failure, the shear connector failure is assumed to be basis for all liner investigations. Design of the liner and its anchorage therefore is based on the analysis of large deformations with regard to elastic-plastic behaviour of liner-material and non-linear anchor characteristics. By this method both economical and safe sizing and spacing of the anchors can be calculated. (orig.)

  15. Optimization in liner shipping

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard; Karsten, Christian Vad; Pisinger, David

    2017-01-01

    Seaborne trade is the lynchpin in almost every international supply chain, and about 90% of non-bulk cargo worldwide is transported by container. In this survey we give an overview of data-driven optimization problems in liner shipping. Research in liner shipping is motivated by a need for handling...... still more complex decision problems, based on big data sets and going across several organizational entities. Moreover, liner shipping optimization problems are pushing the limits of optimization methods, creating a new breeding ground for advanced modelling and solution methods. Starting from liner...... shipping network design, we consider the problem of container routing and speed optimization. Next, we consider empty container repositioning and stowage planning as well as disruption management. In addition, the problem of bunker purchasing is considered in depth. In each section we give a clear problem...

  16. [Designing metal frame removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    Oral health care providers have the full responsibility for designing metal frame removable partial dentures and making all of the necessary preparations. Important principles of design are that the denture should hamper natural cleaning and daily oral hygiene as little as possible and that it

  17. Shear bond strength of a denture base acrylic resin and gingiva-colored indirect composite material to zirconia ceramics.

    Science.gov (United States)

    Kubochi, Kei; Komine, Futoshi; Fushiki, Ryosuke; Yagawa, Shogo; Mori, Serina; Matsumura, Hideo

    2017-04-01

    To evaluate the shear bond strengths of two gingiva-colored materials (an indirect composite material and a denture base acrylic resin) to zirconia ceramics and determine the effects of surface treatment with various priming agents. A gingiva-colored indirect composite material (CER) or denture base acrylic resin (PAL) was bonded to zirconia disks with unpriming (UP) or one of seven priming agents (n=11 each), namely, Alloy Primer (ALP), Clearfil Photo Bond (CPB), Clearfil Photo Bond with Clearfil Porcelain Bond Activator (CPB+Act), Metal Link (MEL), Meta Fast Bonding Liner (MFB), MR. bond (MRB), and V-Primer (VPR). Shear bond strength was determined before and after 5000 thermocycles. The data were analyzed with the Kruskal-Wallis test and Steel-Dwass test. The mean pre-/post-thermalcycling bond strengths were 1.0-14.1MPa/0.1-12.1MPa for the CER specimen and 0.9-30.2MPa/0.1-11.1MPa for the PAL specimen. For the CER specimen, the ALP, CPB, and CPB+Act groups had significantly higher bond strengths among the eight groups, at both 0 and 5000 thermocycles. For the PAL specimen, shear bond strength was significantly lower after thermalcycling in all groups tested. After 5000 thermocycles, bond strengths were significantly higher in the CPB and CPB+Act groups than in the other groups. For the PAL specimens, bond strengths were significantly lower after thermalcycling in all groups tested. The MDP functional monomer improved bonding of a gingiva-colored indirect composite material and denture base acrylic resin to zirconia ceramics. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. Light weight hollow maxillary complete denture: A case series

    Directory of Open Access Journals (Sweden)

    Laxman Singh Kaira

    2012-01-01

    Full Text Available Retention, stability and support are the basic principles on which the success of a complete denture relies on. The skill lies in applying these principles efficiently in critical situations. Residual ridge resorption occurs at a three times faster rate in mandibular arch than in the maxillary arch. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. The consequent weight of the processed complete denture only compromises them further. The severely resorbed jaw can have various treatment options. Extreme resorption of the maxillary denture-bearing area may lead to problems with prosthetic rehabilitation. The advantage of a hollow maxillary or mandibular denture is the reduction of excessive weight of acrylic resin, which normally replaces lost alveolar ridge in the interridge space of the denture wearer. This clinical report describes two case reports of edentulous patients with resorbed ridges where a simplified technique of fabricating a light weight hollow maxillary complete denture was used for the preservation of denture bearing areas.

  19. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    Science.gov (United States)

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  20. Stabilized imploding liner fusion systems

    International Nuclear Information System (INIS)

    Book, D.L.; Cooper, A.L.; Ford, R.; Gerber, K.A.; Hammer, D.A.; Jenkins, D.J.; Robson, A.E.; Turchi, P.J.

    1977-01-01

    A new concept in imploding liner plasma compression is described in which a liquid metal liner is imploded by pistons driven by high-pressure gas, and stability of the inner surface against Rayleigh-Taylor modes is achieved by rotation. The principle has been demonstrated by using a water liner to compress air. This 'captive liner' offers the possibility of stable, reversible implosion-expansion cycles in which the plasma energy is recovered into the driving system, leading to reactor cycles with low Q and, hence, small size. A new method of setting up closed-field confinement geometries inside a liner using a rotating electron beam is described. Plasma currents induced by the beam provide initial plasma heating and generate the containment geometry. Persistence of plasma currents 100 times longer than the beam duration has been observed. Development of these methods could lead to a very compact thermonuclear reactor operating in the manner of a reciprocating engine. (author)

  1. Elderly complete denture wearers: a social approach to tooth loss.

    Science.gov (United States)

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  2. Liner Shipping Fleet Repositioning

    DEFF Research Database (Denmark)

    Tierney, Kevin; Jensen, Rune Møller

    2011-01-01

    Liner shipping fleet repositioning consists of moving vessels between services in a liner ship- ping network in order to better orient the overall network to the world economy, and to ensure the proper maintenance of vessels. Thus, fleet repositioning involves sailing and loading activities subject...

  3. Evaluation of Prevalence of Oral Candidiasis in Patients Using Complete Denture Wears

    Directory of Open Access Journals (Sweden)

    P Tavakkol

    2001-06-01

    Full Text Available Denture stomatotos os a common problem of the denture wears, and its etiology is not clear from the literatures. Some studies show that the aetiology is candida albicans, while other reports point out the other agents including candida albicans. The present study was designed to evaluate the prevalence of oral candidiasis in patients using complete denture with different datas. 50 subjects all wearing complete denture participated in this study. The palatal mucosa was swabbed and swabs were cultured in Sabourauds medium containing 0.005% chloramphenicol then cultures were tested with common mycological lab tests. In 80% of patients oral candidiasis have been diagnosed. In the investigation a direct relation between the oral candidiasis and removal of denture at night, denture cleanliness, presence of any suction and symptoms of denture stomatitis was shown. No relation between the oral candidiasis and sex, smoking habit, succeptible disease, angular cheilitis; the recent condition of denture and the retention of denture were found. The findings of our investigation indicates that candida albicans is the causative agent of denture stomatitis while other factors such as denture cleanliness, removal of denture at night and presence of any suction may be considered as well.

  4. Characterization of EPICOR II Prefilter Liner 3

    International Nuclear Information System (INIS)

    Wynhoff, N.L.; Pasupathi, V.

    1983-04-01

    As part of the overall TMI-2 Information and Examination Program, EPICOR II Prefilter Liner 3 was examined to provide information to aid in the development of technology for safely processing highly loaded ion-exchange media. The characterization program included sampling and analyses of the liner contents, including ion-exchange media, liquids and gases, as well as examinations of the liner interior and exterior. This report details the handling of the liner, sampling and analysis of the contents, and the examinations of the liner

  5. Characterization of EPICOR II Prefilter Liner 16

    International Nuclear Information System (INIS)

    Yesso, J.D.; Pasupathi, V.; Lowry, L.

    1982-08-01

    As part of the overall TMI-2 Information and Examination Program, EPICOR II Prefilter Liner 16 was examined to provide information to aid in the development of technology for safely processing highly loaded ion-exchange media. The characterization program included sampling and analyses of the liner contents, including ion-exchange media, liquids and gases, as well as examinations of the liner interior and exterior. This report details the handling of the liner, sampling and analysis of the contents, and the examinations of the liner

  6. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  7. A clinical evaluation denture adhesives used by patients with xerostomia.

    Science.gov (United States)

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  8. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  9. Alveolar ridge rehabilitation to increase full denture retention and stability

    OpenAIRE

    Mefina Kuntjoro; Rostiny Rostiny; Wahjuni Widajati

    2010-01-01

    Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augme...

  10. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a water...

  11. Accelerating Thick Aluminum Liners Using Pulsed Power

    International Nuclear Information System (INIS)

    Kyrala, G.A.; Hammerburg, J.E.; Bowers, D.; Stokes, J.; Morgan, D.V.; Anderson, W.E.; Cochrane, J.C.

    1999-01-01

    The authors have investigated the acceleration of very thick cylindrical aluminum liners using the Pegasus II capacitory bank. These accelerated solid liners will be used to impact other objects at velocities below 1.5 km/sec, allowing one to generate and sustain shocks of a few 100 kilobar for a few microseconds. A cylindrical shell of 1100 series aluminum with an initial inner radius of 23.61 mm, an initial thickness of 3.0 mm, and a height of 20 mm, was accelerated using a current pulse of 7.15 MA peak current and a 7.4 microsecond quarter cycle time. The aluminum shell was imploded within confining copper glide planes with decreasing separation with an inward slope of 8 degrees. At impact with a cylindrical target of diameter 3-cm, the liner was moving at 1.4 km/sec and its thickness increased to 4.5 mm. Radial X-ray radiograms of the liner showed both the liner and the glide plane interface. The curvature of the inner surface of the liner was measured before impact with the 15-mm radius target. The radiograms also showed that the copper glide planes distorted as the liner radius decreased and that some axial stress is induced in the liner. The axial stresses did not affect the inner curvature significantly. Post-shot calculations of the liner behavior indicated that the thickness of the glide plane played a significant role in the distortion of the interface between the liner and the glide plane

  12. The adhesive strength and initial viscosity of denture adhesives.

    Science.gov (United States)

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  13. The AGN nature of LINER nuclear sources

    Science.gov (United States)

    Márquez, Isabel; Masegosa, Josefa; González-Martin, Omaira; Hernández-Garcia, Lorena; Pović, Mirjana; Netzer, Hagai; Cazzoli, Sara; del Olmo, Ascensión

    2017-11-01

    Low-ionization nuclear emission-line regions (LINERs) are specially interesting objects since not only they represent the most numerous local Active Galactic Nuclei population, but they could be the link between normal and active galaxies as suggested by their low X-ray luminosities. The origin of LINER nuclei being still controversial, our works, through a multiwavelength approach, have contributed, firstly, to confirm that a large number of nuclear LINERs in the local universe are AGN powered. Secondly, from the study of X-ray spectral variability, we found that long term variations are very common, and they are mostly related to hard energies (2-10 keV). These variations might be due to changes in the absorber and/or intrinsic variations of the source. Thirdly, Mid-infrared (MIR) imaging also indicates that LINERs are the low luminosity end of AGN towards lower luminosities, and MIR spectroscopy shows that the average spectrum of AGN-dominated LINERs with X-ray luminosities L_X(2-10 keV) > 10^{41} erg/s is similar to the average mid-IR spectrum of AGN-dominated Seyfert 2s; for fainter LINERS, their spectral shape suggests that the dusty-torus may disappear. Fourth, the extended Hα emission of LINERs at HST resolution indicates that they follow remarkably well the Narrow Line Region morphology and the luminosity-size relation obtained for Seyfert and QSOs; HST Hα morphology may suggest the presence of outflows, which could contribute to the line broadening, with the resulting consequences on the percentage of LINERs where the Broad Line Region is detected. This issue is being revisited by our group with a high spectral resolution set of optical data for nearby type-1 LINERs. Finally, concerning systematic studies on the role of star formation in LINERs, which are scarce, our contribution deals with the study of a sample of the most luminous, highest star formation rate LINERs in the local Universe (at z from 0.04 to 0.11), together with its comparison with both

  14. The AGN Nature of LINER Nuclear Sources

    Energy Technology Data Exchange (ETDEWEB)

    Márquez, Isabel; Masegosa, Josefa [Instituto de Astrofisica de Andalucia (CSIC), Granada (Spain); González-Martin, Omaira [Instituto de Radioastronomía y Astrofísica, Universidad Nacional Autónoma de México, Morelia (Mexico); Hernández-Garcia, Lorena [Istituto di Astrofisica e Planetologia Spaziali, Rome (Italy); Pović, Mirjana [Instituto de Astrofisica de Andalucia (CSIC), Granada (Spain); Ethiopian Space Science and Technology Institute and Entoto Observatory and Research Center, Addis Ababa (Ethiopia); Netzer, Hagai [Raymond and Beverly Sackler Faculty of Exact Sciences, School of Physics and Astronomy and the Wise Observatory, Tel-Aviv University, Tel Aviv (Israel); Cazzoli, Sara; Olmo, Ascensión del, E-mail: isabel@iaa.es [Instituto de Astrofisica de Andalucia (CSIC), Granada (Spain)

    2017-11-16

    Low-ionization nuclear emission-line regions (LINERs) are specially interesting objects since not only they represent the most numerous local Active Galactic Nuclei population, but they could be the link between normal and active galaxies as suggested by their low X-ray luminosities. The origin of LINER nuclei being still controversial, our works, through a multiwavelength approach, have contributed, firstly, to confirm that a large number of nuclear LINERs in the local universe are AGN powered. Secondly, from the study of X-ray spectral variability, we found that long term variations are very common, and they are mostly related to hard energies (2–10keV). These variations might be due to changes in the absorber and/or intrinsic variations of the source. Thirdly, Mid-infrared (MIR) imaging also indicates that LINERs are the low luminosity end of AGN toward lower luminosities, and MIR spectroscopy shows that the average spectrum of AGN-dominated LINERs with X-ray luminosities L{sub X}(2–10 keV) > 10{sup 41} erg/s is similar to the average mid-IR spectrum of AGN-dominated Seyfert 2s; for fainter LINERS, their spectral shape suggests that the dusty-torus may disappear. Fourth, the extended Hα emission of LINERs at HST resolution indicates that they follow remarkably well the Narrow Line Region morphology and the luminosity-size relation obtained for Seyfert and QSOs; HST Hα morphology may suggest the presence of outflows, which could contribute to the line broadening, with the resulting consequences on the percentage of LINERs where the Broad Line Region is detected. This issue is being revisited by our group with a high spectral resolution set of optical data for nearby type-1 LINERs. Finally, concerning systematic studies on the role of star formation in LINERs, which are scarce, our contribution deals with the study of a sample of the most luminous, highest star formation rate LINERs in the local Universe (at z from 0.04 to 0.11), together with its comparison

  15. The AGN Nature of LINER Nuclear Sources

    International Nuclear Information System (INIS)

    Márquez, Isabel; Masegosa, Josefa; González-Martin, Omaira; Hernández-Garcia, Lorena; Pović, Mirjana; Netzer, Hagai; Cazzoli, Sara; Olmo, Ascensión del

    2017-01-01

    Low-ionization nuclear emission-line regions (LINERs) are specially interesting objects since not only they represent the most numerous local Active Galactic Nuclei population, but they could be the link between normal and active galaxies as suggested by their low X-ray luminosities. The origin of LINER nuclei being still controversial, our works, through a multiwavelength approach, have contributed, firstly, to confirm that a large number of nuclear LINERs in the local universe are AGN powered. Secondly, from the study of X-ray spectral variability, we found that long term variations are very common, and they are mostly related to hard energies (2–10keV). These variations might be due to changes in the absorber and/or intrinsic variations of the source. Thirdly, Mid-infrared (MIR) imaging also indicates that LINERs are the low luminosity end of AGN toward lower luminosities, and MIR spectroscopy shows that the average spectrum of AGN-dominated LINERs with X-ray luminosities L X (2–10 keV) > 10 41 erg/s is similar to the average mid-IR spectrum of AGN-dominated Seyfert 2s; for fainter LINERS, their spectral shape suggests that the dusty-torus may disappear. Fourth, the extended Hα emission of LINERs at HST resolution indicates that they follow remarkably well the Narrow Line Region morphology and the luminosity-size relation obtained for Seyfert and QSOs; HST Hα morphology may suggest the presence of outflows, which could contribute to the line broadening, with the resulting consequences on the percentage of LINERs where the Broad Line Region is detected. This issue is being revisited by our group with a high spectral resolution set of optical data for nearby type-1 LINERs. Finally, concerning systematic studies on the role of star formation in LINERs, which are scarce, our contribution deals with the study of a sample of the most luminous, highest star formation rate LINERs in the local Universe (at z from 0.04 to 0.11), together with its comparison with

  16. Study of imploding liner-electrode wall interaction

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshev, V K; Zharinov, E I; Mokhov, V N [All-Russian Scientific Research Institute of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Acceleration of solid aluminium liners and their interaction with electrodes is studied experimentally. One of the main goal of the experiments is to find the method of improving the contact between the liner and the electrode during the acceleration process. Two independent liners connected in series in one discharge circuit are used. This arrangement makes it possible to record two different liner positions simultaneously at one discharge current. As an energy source, a helical explosive magnetic generator of the length of 0.7 m and 100 mm in diameter is used. The shape of liners at various stages of acceleration is recorded by using a flash radiographic facility. The measured liner flight velocity and the compression radius are compared with the results of MHD model calculations. (J.U.). 21 figs., 7 refs.

  17. [Oral mucosa reaction in patients adapting to removable dentures].

    Science.gov (United States)

    Iordanishvili, A K; Soldatova, L N; Pihur, O L; Mihajlova, E S; Peremyshlenko, A S; Soldatov, V S

    Oral mucosa reaction of prosthetic bed to the removable acrylic dentures was evaluated in 43 patients (12 male and 31 female) aged 56-69 years with partial and full teeth loss in one or both jaws. Patients of the first (control) group (17 patients) were not using additional tools improving fixation of the removable dentures during adaptation period, while patients of the second (main) group (26 patients) used Corega cream for dentures fixation for 30 days follow-up. Oral mucosa assessment was carried out on 3-4 and 28-30 day of dentures use by 3 end points: pain syndrome, moisture level, inflammation of a prosthetic bed. The results proved Corega cream to improve prosthetic bed mucosa condition reducing inflammatory response to polymeric materials of removable dentures basis.

  18. The effect of denture adhesives on Candida albicans growth in vitro.

    Science.gov (United States)

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  19. A simple approach to hollow maxillary complete denture fabrication: An innovative technique

    Directory of Open Access Journals (Sweden)

    Kathleen Manuela D'souza

    2017-01-01

    Full Text Available A severely atrophic maxillary arch exhibits reduced denture bearing area and increased inter-ridge distance, thus, affecting retention of the complete denture. Such clinical situations necessitate the fabrication of a hollow complete denture to reduce the weight of the prosthesis and increase retention. This article describes a simple technique to fabricate a hollow maxillary complete denture using salt and thermoplastic poly (methyl methacrylate sheet. The vacuum-formed thermoplastic matrix regulates the quantity of salt and determines its placement in the unpolymerized denture base material during the denture packing stage. The matrix lining the hollow cavity also aids to reinforce the hollow denture base.

  20. Variable volume combustor with a conical liner support

    Science.gov (United States)

    Johnson, Thomas Edward; McConnaughhay, Johnie Franklin; Keener, Chrisophter Paul; Ostebee, Heath Michael

    2017-06-27

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a conical liner support supporting the liner.

  1. Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis.

    Directory of Open Access Journals (Sweden)

    Yeganeh Memari

    2014-10-01

    Full Text Available Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stress distribution, in distal extension implant assisted removable partial dentures.Three-dimensional models of a bilateral distal extension partially edentulous mandible containing anterior teeth and first premolar in both sides of the arch, a partial removable denture and an implant (4×10mm were designed. With the aid of the finite element program ANSYS 8.0, the models were meshed and strictly vertical forces of 10 N were applied to each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.When an implant was placed in the second premolar region, the highest stress on implant, abutment tooth and cancellous bone was shown. The lowest stress was shown on implant and bone in the 1(st molar area.Implants located in the first molar area showed the least distribution of stresses in the analyzed models.

  2. Different types of antagonists modify the outcome of complete denture renewal.

    Science.gov (United States)

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  3. Thermoplastic liners for carbon steel pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Mehdi, Mauyed S.; AlDossary, Abdullah K. [Saudi Aramco, Dhahran (Saudi Arabia)

    2009-12-19

    Materials selection for pipe and fittings used to convey corrosive fluids has often been a challenge. Traditionally, exotic Corrosion Resistant Alloys (CRA) have been used in corrosive environments despite their high cost. Plastic lined carbon steel piping offers a cost effective alternative to the use of CRAs by eliminating corrosion, significantly reducing the use of toxic chemicals and the heavy metal usually present in CRAs. Thermoplastic Liners offer the combination of corrosion resistance and mechanical strength, which are unachievable with singular materials. Under pressure conditions, the liner is fully supported by the metalwork, while under vacuum conditions, the liner must be thick enough along with venting system to withstand the collapsing forces created by the negative pressure. Plastic liners have been used successfully to line and protect metallic pipelines for many years and have become an indispensable requirement of the oil and gas industry particularly with water injection and hydrocarbon services. In the case of internally corroded pipes, the use of thermoplastic liners for rehabilitation is an option to extend the lifetime of companies' assets, reduce maintenance cost and increase intervals between T and Is. For new construction, plastic liners in carbon steel pipes can compete technically and economically with pipelines of CRA materials and other corrosion inhibition systems. This paper describes various design features, installations of thermoplastic liners in comparison to other corrosion inhibition methods. (author)

  4. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Science.gov (United States)

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  5. Magnetized Target Fusion Driven by Plasma Liners

    Science.gov (United States)

    Thio, Y. C. Francis; Cassibry, Jason; Eskridge, Richard; Kirkpatrick, Ronald C.; Knapp, Charles E.; Lee, Michael; Martin, Adam; Smith, James; Wu, S. T.; Rodgers, Stephen L. (Technical Monitor)

    2001-01-01

    For practical applications of magnetized target fusion, standoff drivers to deliver the imploding momentum flux to the target plasma remotely are required. Quasi-spherically converging plasma jets have been proposed as standoff drivers for this purpose. The concept involves the dynamic formation of a quasi-spherical plasma liner by the merging of plasma jets, and the use of the liner so formed to compress a spheromak or a field reversed configuration (FRC). Theoretical analysis and computer modeling of the concept are presented. It is shown that, with the appropriate choice of the flow parameters in the liner and the target, the impact between the liner and the target plasma can be made to be shockless in the liner or to generate at most a very weak shock in the liner. Additional information is contained in the original extended abstract.

  6. Polybore : an innovative casing liner and patch technology

    Energy Technology Data Exchange (ETDEWEB)

    Hayward, C. [Trican Well Service Ltd., Calgary, AB (Canada)

    2003-07-01

    This PowerPoint presentation provided several images on how to install a polybore tight fitting wellbore liner developed by Trican Well Service. The high density polyethylene liner is spooled and rolled into a reducer well where weights are maintained until the liner is in place. The liner offers corrosion protection, corrosion control, chemical resistance, and wear resistance. The liner helps to optimize water injection, well disposal, as well as carbon dioxide injection. It can be placed at depths up to 2,000 m and is well suited to repair pin hole leaks or plug off existing perforations that were previously cemented. The liner can be used to repair and control wellbore corrosion at specific intervals. This presentation provides a brief history of the development of the wellbore liner along with some installation case studies. The thermal velocity liner developed by Trican insulates fluids from heat loss. It prevents liquid dropout and paraffin formation in gas wells. The liner can be used as a replacement for tubing or a loose fit liner. Erosion rates were illustrated. The system, however, is limited because the wellbore casing must be round and scraped and it cannot be used in highly deviated wells. The economic benefits of injection and disposal well applications include power savings, quick payback, corrosion resistance, and lower repair costs. The liners are more cost effective than conventional steel patch. 1 tab., 14 figs.

  7. Flexible removable partial dentures: a basic overview.

    Science.gov (United States)

    Hill, Edward E; Rubel, Barry; Smith, John B

    2014-01-01

    For many years, flexible resin materials have been available for fabricating removable partial denture (RPD) prostheses. Using a nonrigid material for the major connector or other components of an RPD may be a consideration for certain patients. Except for the promotional literature that has been written for flexible resin dentures, there is very little information available in the dental literature concerning nonrigid RPDs. As a result, the decision to use this treatment option depends on the judgment and experience of the dentist and fabricating laboratory. This article summarizes clinically pertinent information about flexible, nonrigid partial dentures.

  8. Can the liner be landed on the well bottom?; Posso apoiar o liner no fundo do poco?

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Carlos Fernando Humbert [PETROBRAS, Rio de Janeiro, RJ (Brazil). Departamento de Perfuracao. Div. de Suporte Tecnico

    1994-07-01

    During the 7 in.liner run-in operation in well 1-BSS-65 with the shoe depth at 2400 m, the setting string broke and, as a result, the whole array fell from 2800 m high. Through a fishing operation, the liner (setting tool) was recovered and later a casing string sticking was detected. Full fluid circulation was obtained and the possibility was considered of cementing the liner in that position. At this point three questions were asked to assess the feasibility of such a cementing operation: were there significant damages inflicted on the liner string as a result of the fall?; if no damages resulted from the fall, would liner bucking prevent the running in of completion tools?; would the casing withstand the strains caused by buckling? This paper addresses the two latter questions through the theory of helical bucking of the tubing confined within a cylinder. Equations are introduced to calculate the helical pitch and the axial strain due to bending. A user-friendly computer program was developed to apply this theory to instances such as the above-mentioned one or to eliminate the use of hangers with short liners. The results of the analysis carried out on this particular well are presented and an assessment of the main parameters bearing on the issue is undertaken. These parameters are: well diameter and liner length. (author)

  9. Trial of an experimental castor oil solution for cleaning dentures.

    Science.gov (United States)

    Andrade, Ingrid Machado de; Andrade, Kelly Machado de; Pisani, Marina Xavier; Silva-Lovato, Cláudia Helena; de Souza, Raphael Freitas; Paranhos, Helena de Freitas Oliveira

    2014-01-01

    Denture hygiene is essential because denture biofilm is involved in oral infections and systemic diseases. Although there are chemical agents available on the market, none of them have ideal properties and research on such products is still necessary. The aim of this study was to evaluate the efficacy of a castor bean (Ricinus communis)-based solution for removing denture biofilm, compared to two traditional products (sodium hypochlorite and alkaline peroxide). Fifty maxillary complete denture wearers were instructed to brush their dentures after meals and to immerse their dentures once a day in the following solutions: Saline (20 min; control), Polident alkaline peroxide (3 min), NaOCl (20 min) and 2% castor oil solution (20 min). Participants used each solution for a period of 7 consecutive days, according to a random sequence. After each period, the internal surfaces of maxillary complete dentures were stained with a disclosing solution (1% neutral red), photographed and the disclosed biofilm was quantified with the aid of specific software. The influence of treatments on results was verified by the Friedman test (α=0.05). Tested solutions presented significant difference (Fr=51.67; pcastor oil presented intermediate results (median: 1.0% and 1.5%, respectively). It can be concluded that the castor oil solution tested in this study was comparable to alkaline peroxide in terms of efficiency in denture biofilm removal.

  10. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  11. Removable partial denture on osseointegrated implants and natural teeth.

    Science.gov (United States)

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  12. Magnetic attachment for implant overdentures: influence of contact relationship with the denture base on stability and bending strain.

    Science.gov (United States)

    Yang, Tsung-Chieh; Maeda, Yoshinobu; Gonda, Tomoya; Wada, Masahiro

    2013-01-01

    This study evaluated how the contact height between the magnetic attachment and denture base influences stability and bending strain. An implant modified with strain gauges and a magnetic attachment mounted in an acrylic resin block were used to characterize systems with varying degrees or heights of contact with the abutment. Bending strain under lateral loading increased significantly as the contact height decreased. In the no contact and resilient contact groups, magnetic assemblies separated at reduced bending strain in all loading conditions. The contact height of the magnetic attachment influenced the stability and the amount of bending strain on the implant.

  13. Dynamic stabilization of imploding liquid metal liner

    International Nuclear Information System (INIS)

    Itoh, Yasuyuki; Fujiie, Yoichi

    1979-01-01

    The rotational stabilization has been proposed against the Rayleigh-Taylor instability of the imploding liquid metal liner. In this paper, the discussion is made on the possibility of the dynamic stabilization by applying the oscillating azimuthal magnetic field in addition to the axial field. In contrast to the rotational stabilization, the required (field) energy for this stabilization is also used for the liner driving or the plasma confinement. In the analysis, the liner subjected to the acceleration is assumed to be infinitely long, at rest and have the situation at the start of the implosion or turnaround. At turnaround, the existence of the plasma is taken into account. The perturbed motion of the liner is discussed with a linear stability analysis. Results are as follows: (1) The dynamic stabilization at the start of the implosion is possible if the distance from the conducting wall to the liner outer surface is comparable with or less than the liner thickness. (2) At turnaround, the stability is improved with decreasing the ratio of the plasma radius to that of the liner inner surface however the kink mode (m = 1) cannot be suppressed. (author)

  14. Effect of Microwave Cured Acrylic Resin on Candidal Growth in Complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on Candidal growth. Seven completely edentulous male patients with no history of denture wearing participated in this study. All the selected patients were re-habilitated by mucosa supported complete dentures. The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. One month resting period was allowed so as Candidal count can reach to normal. Then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique. In the oral rinse technique, the patients were instructed to rinse their mouths with 10 mL of sterile phosphate buffered saline for 60 seconds. The rinse was then expectorated into a universal container and immediately transported to the laboratory for concentration by centrifugation, then cultured on sabouraud's dextrose agar plates which were incubated at 37 degree C for 48 hours. Microscopic examination and germ tube test were carried out for laboratory investigations. In addition, the morphological features of the isolated Candida from the samples tested in this study, were investigated using the scanning electron microscope(SEM)

  15. Conceptual design of imploding liner fusion reactors

    International Nuclear Information System (INIS)

    Turchi, P.J.; Robson, A.E.

    1976-01-01

    The basic new ingredient is the concept of rotationally stabilized liquid metal liners accelerated with free pistons. The liner motion is constrained on its outer surface by the pistons, laterally by channel walls, during acceleration, and on its inner surface, where megagauss field levels are attained by the centrifugal motion of the liner material. In this way, stable, reversible motion of the liner should be possible, permitting repetitive, pulsed operation at interior pressures far greater than can be allowed in static conductor systems. Such higher operating pressures permit the use of simple plasma geometries, such as theta pinches, with greatly reduced dimensions. Furthermore, the implosion of thick, lithium-bearing liners with large radial compression ratios inherently provides the plasma with a surrounding blanket of neutron absorbing liquid metal, thereby substantially reducing the problems of induced radioactivity and first wall damage that haunt conventional fusion reactor designs. The following article discusses the basic operation of liner reactors and several important features influencing their design

  16. Lost and found…Tracking a swallowed denture: Role of radiology

    Directory of Open Access Journals (Sweden)

    Yogita Khalekar

    2017-01-01

    Full Text Available Denture ingestion or aspiration is a problem requiring awareness of different specialists including dentists, surgeons, otolaryngologists, and anesthesiologists for prevention, early diagnosis and adequate treatment. Complications of swallowed dentures include hollow viscous necrosis, perforation, and penetration to neighbouring organs leading to fistulae, bleeding and obstruction. Here, we present the case of a 65 year old female patient who swallowed the denture, which was detected by barium swallow and removed by endoscopy. Hence, the management of swallowed denture needs a multidisciplinary approach with the help of a dentist, otolaryngologist and anesthesiologists. Dentists should recommend patients to visit them for planned check ups or revisit them in case of denture dislodgement or loosening as soon as possible to prevent such life threatening events.

  17. Expectations and satisfaction of denture patients in a university clinic.

    Science.gov (United States)

    Davis, E L; Albino, J E; Tedesco, L A; Portenoy, B S; Ortman, L F

    1986-01-01

    These results indicate that patients' expectations of dentures before treatment were unrealistically high and that informational videotapes did not significantly affect these expectations. Satisfaction with current dentures was surprisingly high before treatment and increased significantly from pretreatment to postreatment for both groups in the study. While it is likely that this increase in satisfaction reflects a change from poor to excellent denture status, this finding may also be attributed to cognitive dissonance theory; that is, high satisfaction may represent the means by which patients justify the expenses of their denture treatment. Although the videotape presentations did not alter the expectations of patients and their satisfaction with dentures, the tapes represent a potential source of accurate, standardized information for both patient and student dentist.

  18. [Routine oral examinations and specific after-care for removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    Following treatment with a removable partial denture, routine oral examinations are required to stabilize the existing condition in a sustainable way and to make possible the timely treatment of anomalies which have appeared. In cases of problems assessed during a routine oral examination in relation to the removable partial dentures, maintenance, restorative and prosthetic treatment may be indicated. Maintenance treatments are indicated for small and easily retrievable alterations. In removable partial denture treatment, adequate space between prepared tooth and denture is essential. Possible prosthetic treatments of a removable partial denture are relining, rebasing, improving or renewing the maxillomandibular relation, repairment, and extension.

  19. HOST liner cyclic facilities: Facility description

    Science.gov (United States)

    Schultz, D.

    1982-01-01

    A quartz lamp box, a quartz lamp annular rig, and a low pressure liner cyclic can rig planned for liner cyclic tests are described. Special test instrumentation includes an IR-TV camera system for measuring liner cold side temperatures, thin film thermocouples for measuring liner hot side temperatures, and laser and high temperature strain gages for obtaining local strain measurements. A plate temperature of 2,000 F was obtained in an initial test of an apparatus with three quartz lamps. Lamp life, however, appeared to be limited for the standard commercial quartz lamps available. The design of vitiated and nonvitiated preheaters required for the quartz lamp annular rig and the cyclic can test rigs is underway.

  20. Posterior Mandibular Ridge Resorption Associated with Different Retentive Systems for Overdentures: A 7-Year Retrospective Preliminary Study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Mohamed, Shahinaz Sayed; Shawky, Ahmad Fathalla

    This retrospective study compared posterior mandibular residual ridge resorption with two different retentive mechanisms for overdentures after 7 years. A convenience sample of 18 edentulous men was assigned to one of two equal groups. Two implants were placed in the mandibular canine areas for each patient using the conventional two-stage surgical protocol, and the implants were splinted with a round bar 3 months later. New mandibular overdentures were then connected to the bars with clips (clip-retained overdentures, CR group) or resilient liners (resilient liner-retained overdentures, RR group). Posterior mandibular ridge resorption (PMRR) was recorded using proportional measurements and posterior area index (PAI) on panoramic radiographs taken immediately after overdenture insertion (T 0 ) and 7 years later (T 7 ). A linear regression model was used to verify the relationship between PAI and the following considerations: attachment type, age, initial mandibular ridge height, period of mandibular edentulism, number of previously worn dentures, and relining events. After 7 years, the RR group demonstrated a significantly (P = .014) higher change in PAI (0.11 ± 0.02) than the CR group (0.06 ± 0.04). The average PMRR for each mm of posterior mandibular ridge was 0.79 mm (0.11 mm/year) in the CR group and 1.4 mm (0.2 mm/year) in the RR group. Attachment type, initial mandibular ridge height, and relining times were significantly correlated with change in the PAI (P = .004, P = .035, and P = .045, respectively). Within the limitations of this preliminary study's design, it was observed that following a 7-year period of use, resilient liner attachments for bar/implant-retained overdentures appear to be associated with greater posterior mandibular ridge resorption when compared to clip attachments.

  1. Geosynthetic clay liners shrinkage under simulated daily thermal cycles.

    Science.gov (United States)

    Sarabadani, Hamid; Rayhani, Mohammad T

    2014-06-01

    Geosynthetic clay liners are used as part of composite liner systems in municipal solid waste landfills and other applications to restrict the escape of contaminants into the surrounding environment. This is attainable provided that the geosynthetic clay liner panels continuously cover the subsoil. Previous case histories, however, have shown that some geosynthetic clay liner panels are prone to significant shrinkage and separation when an overlying geomembrane is exposed to solar radiation. Experimental models were initiated to evaluate the potential shrinkage of different geosynthetic clay liner products placed over sand and clay subsoils, subjected to simulated daily thermal cycles (60°C for 8 hours and 22°C for 16 hours) modelling field conditions in which the liner is exposed to solar radiation. The variation of geosynthetic clay liner shrinkage was evaluated at specified times by a photogrammetry technique. The manufacturing techniques, the initial moisture content, and the aspect ratio (ratio of length to width) of the geosynthetic clay liner were found to considerably affect the shrinkage of geosynthetic clay liners. The particle size distribution of the subsoil and the associated suction at the geosynthetic clay liner-subsoil interface was also found to have significant effects on the shrinkage of the geosynthetic clay liner. © The Author(s) 2014.

  2. Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou; Agha, Nora Nory; Habib, Ahmed Ali

    2016-01-01

    The aim of this study was to evaluate and compare the retention and stability of mandibular implant overdentures using different types of resilient attachments. Two implant analogs were inserted in the canine areas of an acrylic edentulous mandibular model. A metal-reinforced experimental overdenture was constructed and connected to the implant analogs (on two occasions) using either resilient telescopic or Locator attachments. Locators were divided into three subgroups according to the degree of retention of the male nylon insert: Locator extra-light retention (blue insert), Locator light retention (pink insert), and Locator medium retention (transparent insert). Vertical and oblique (anterior, posterior, and lateral) dislodging forces were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention). For all dislodging forces, Locator medium recorded the highest initial and final retention. Telescopic attachments recorded the lowest retention during vertical and anterior dislodging, and Locator extra-light recorded the lowest retention during lateral and posterior dislodging. For all types of Locator attachments, anterior dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For the telescopic attachment, posterior dislodgment recorded the highest initial and final retention, and anterior dislodging recorded the lowest retention. After repeated denture insertions and removals, the highest retention and stability were recorded with Locator medium followed by Locator light. The lowest retention was recorded with resilient telescopic attachment, and the lowest stability was recorded with Locator extra-light.

  3. Fusion power from fast imploding liners

    International Nuclear Information System (INIS)

    Krakowski, R.A.; Moses, R.W.; Miller, R.L.; Germwin, R.A.

    1977-01-01

    An approach to fusion power is described which proposes magnetically driving a thin metal shell at high velocity (approximately 10 4 m/s) onto a warm (200 to 500 eV), dense (10 24 to 10 25 m -3 ) plasma. A description of the plasma/liner interaction by several analytic and numerical models is given. On the basis of theoretical scaling predictions, the advantages, disadvantages and uncertainties associated with a high-efficiency (recirculating power fraction less than or equal to 0.2) Fast-Liner Reactor (FLR) are described, quantified when possible, and summarized. The FLR approach is characterized by (1) a thin cylindrical nonrotating liner that would be magnetically accelerated by axial currents driven through the liner (no external coils or magnets), (2) axial and radial energy confinement would be provided by an azimuthal magnetic field associated either with axial currents driven through a hard core or through the plasma, (3) the plasma particle pressure would be supported directly by the liner surface and material end plugs, and (4) the liner and a portion of associated support structure would be destroyed at each implosion. A preliminary assessment of the technological implications of blast confinement, materials destruction and loss, energy transfer and storage requirements, and possible modes of FLR operation is presented

  4. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  5. The critical thickness of liners of Cu interconnects

    International Nuclear Information System (INIS)

    Jiang, Q; Zhang, S H; Li, J C

    2004-01-01

    A model for the size-dependence of activation energy is developed. With the model and Fick's second law, relationships among the liner thickness, the working life and the working temperature of a TaN liner for Cu interconnects are predicted. The predicted results of the TaN liner are in good agreement with the experimental results. Moreover, the critical thicknesses of liners of some elements are calculated

  6. Compression of toroidal plasma by imploding plasma-liner

    International Nuclear Information System (INIS)

    Ikuta, Kazunari.

    1979-07-01

    A new concept of compressing a plasma in a closed magnetic configuration by a version of liner implosion flux compression technique is considered. The liner consists of a dense plasma cylinder, i.e. the plasma-liner. Maximum compression ratio of toroidal plasma is determined just by the initial density ratio of the toroidal plasma to the liner plasma because of the Rayleigh-Taylor instability. A start-up senario of plasma-liner is also proposed with a possible application of this concept to the creation of a burning plasma in reversed field configurations, i.e. burning plasma vortex. (author)

  7. The Liner Shipping Fleet Repositioning Problem with Cargo Flows

    DEFF Research Database (Denmark)

    Tierney, Kevin; Jensen, Rune Møller

    2012-01-01

    We solve an important problem for the liner shipping industry called the Liner Shipping Fleet Repositioning Problem (LSFRP). The LSFRP poses a large financial burden on liner shipping firms. During repositioning, vessels are moved between services in a liner shipping network. Shippers wish...

  8. Composite Liner, Multi-Megabar Shock Driver Development

    International Nuclear Information System (INIS)

    Cochrane, J.C. Jr.; Bartsch, R.R.; Clark, D.A.; Morgan, D.V.; Anderson, W.E.; Lee, H.; Bowers, R.L.; Atchison, W.L.; Oona, H.; Stokes, J.L.; Veeser, L.R.; Broste, W.B.

    1998-01-01

    The multi-megabar shock driver development is a series of experiments in support of the Los Alamos High Energy Density Physics Experimental Program. Its purpose is to develop techniques to impact a uniform, stable, composite liner upon a high Z target to produce a multi-megabar shock for EOS studies. To date, experiments have been done on the Pegasus II capacitor bank with a current of approximately12MA driving the impactor liner. The driving field is approximately200 T at the target radius of 1cm. Data will be presented on the impactor liner. The driving field is approximately200 T at the target radius of 1 cm. Data will be presented on the stability and uniformity of the impactor liner when it impacts the target cylinder. Three experiments have been done with emphasis on liner development. Shock pressures greater than a megabar have been done with emphasis on liner development. Shock pressures greater than a megabar have been produced with an Al target cylinder. A Pt target cylinder should produce shock pressures in th e 5-megabar range

  9. Influence of denture adhesives on occlusion and disocclusion times.

    Science.gov (United States)

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (PAdhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Liner Stability Experiments at Pegasus: Diagnostics and Experimental Results

    International Nuclear Information System (INIS)

    Clark, D.A.; Morgan, D.V.; Rodriguez, G.

    1998-01-01

    A series of experiments to compare imploding liner performance with magneto-hydrodynamic (MHD) modeling has been performed at the Los Alamos National Laboratory Pegasus II pulse power machine. Liner instability growth originating from initial perturbations machined into the liner has been observed with high resolution. Three major diagnostics were used: radiography, Velocity Interferometer for a Surface of Any Reflector (VISAR), and fiber optic impact pins. For radiography, three flash x-ray units were mounted radially to observe liner shape at three different times during the implosion. Liner velocity was measured continuously with the VISAR for the entire distance traveled in two experiments. Optical impact pins provide a high-resolution measure of liner symmetry and shape near the end of travel. Liner performance has compared well with predictions

  11. Evaluation of efficacy of commercial denture cleansing agents to reduce the fungal biofilm activity from heat polymerized denture acrylic resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Mithilesh M Dhamande

    2012-01-01

    Full Text Available Aims: To compare and evaluate Candida removing effects of three most commonly available varieties of commercial denture cleansers from heat polymerized acrylic resins. To compare and evaluate Candida lytic effects of denture cleansers. To assess the effect of time on ability of denture cleansers in reducing Candidal biofilm. Materials and Methods: A specially designed metal mold was fabricated to obtain wax plates of uniform dimensions which were used to fabricate heat cure acrylic resin plates. A square-shaped window of dimension 15 mm and thickness of 1.5 mm was provided in metal mould to simulate thickness of denture base. All samples used in this study were prepared using this mould. Candida albicans colonies were then cultured on this acrylic resin plates by colonization assay. Yeast removing test for samples was performed using microscope and yeast lytic test was performed using photo colorimeter. Results: Denture cleanser D2 showed the highest Candida removing activity when compared with cleansers D1, D3, and control solution. Denture cleansers D2 showed increased yeast lytic ability when compared with denture cleansers D1, D3, and control solution. More time span shared a definite influence on yeast lytic ability of denture cleansers. Conclusions: The effect of cleansing agents on removal of colonized yeasts particularly fungal biofilm from acrylic resins was assessed for clinical implications. The observation indicated superior performance of cleanser D2 when compared with D1 and D3 even though they all belong to same chemical group of alkaline peroxide. The increased effectiveness may be due to presence of sodium lauryl sulphate in formula of D2.

  12. Ecology of Candida-associated Denture Stomatitis

    OpenAIRE

    Budtz-Jørgensen, Ejvind

    2011-01-01

    Introduction of a prosthesis into the oral cavity results in profound alterations of the environmental conditions as the prosthesis and the underlying mucosa become colonized with oral microorganisms, including Candida spp. This may lead to denture stomatitis, a non-specific inflammatory reaction against microbial antigens, toxins and enzymes produced by the colonizing microorganisms. The role of Candida in the etiology of denture stomatitis is indicated by an increased number of yeasts on th...

  13. Solving the Liner Shipping Fleet Repositioning Problem with Cargo Flows

    DEFF Research Database (Denmark)

    Tierney, Kevin; Askelsdottir, Björg; Jensen, Rune Møller

    2015-01-01

    We solve a central problem in the liner shipping industry called the liner shipping fleet repositioning problem (LSFRP). The LSFRP poses a large financial burden on liner shipping firms. During repositioning, vessels are moved between routes in a liner shipping network. Liner carriers wish...

  14. Development of 1D Liner Compression Code for IDL

    Science.gov (United States)

    Shimazu, Akihisa; Slough, John; Pancotti, Anthony

    2015-11-01

    A 1D liner compression code is developed to model liner implosion dynamics in the Inductively Driven Liner Experiment (IDL) where FRC plasmoid is compressed via inductively-driven metal liners. The driver circuit, magnetic field, joule heating, and liner dynamics calculations are performed at each time step in sequence to couple these effects in the code. To obtain more realistic magnetic field results for a given drive coil geometry, 2D and 3D effects are incorporated into the 1D field calculation through use of correction factor table lookup approach. Commercial low-frequency electromagnetic fields solver, ANSYS Maxwell 3D, is used to solve the magnetic field profile for static liner condition at various liner radius in order to derive correction factors for the 1D field calculation in the code. The liner dynamics results from the code is verified to be in good agreement with the results from commercial explicit dynamics solver, ANSYS Explicit Dynamics, and previous liner experiment. The developed code is used to optimize the capacitor bank and driver coil design for better energy transfer and coupling. FRC gain calculations are also performed using the liner compression data from the code for the conceptual design of the reactor sized system for fusion energy gains.

  15. On decisive factors of liner anchorage behaviour

    International Nuclear Information System (INIS)

    Bucchardt, F.; Weber, M.; Yazdi, F.

    1984-01-01

    Design of reinforced and prestressed containments for nuclear power plants in the FRG shall be guided by DIN 25459; this also includes the structural behaviour of the liner. While the containment safety analysis is a more global matter, the liner and especially the liner anchorage behaviour concentrates on local effects which need a more refined local area description. Due to the predominant stiffness of the concrete structure liner failure analysis are performed by decoupling the steel membrane which is then only supported by anchorage springs. A comprehensive nonlinear analytical study is carried out to examine the anchorage behaviour. (Author) [pt

  16. Poor oral hygiene, wearing dentures at night, perceptions of mouth dryness and burning, and lower educational level may be related to oral malodor in denture wearers.

    Science.gov (United States)

    Garrett, Neal R

    2010-03-01

    The study sample was recruited from edentulous patients seeking new dentures at the Kirikkale University Denture Clinic, Turkey. Male (n = 56) and female (n = 49) participants were enrolled and ranged from 50 to 78 years of age (mean age 60.7 6 7.7 years). All 105 completed baseline evaluations, new denture therapy, and follow-up examination approximately 4 weeks after denture treatment completion. The study was approved by the institution's Ethics Committee. Dates for patient recruitment and conduct of the study were not provided. For the prognostic component of the study, the primary factors of interest were sociodemographic characteristics, medical conditions previously related to oral malodor, and self-reported oral hygiene habits. The primary exposure for the interventional component was oral hygiene instruction, including brushing the tongue, cleaning the denture, and not wearing the denture at night. After treatment with new dentures, participants were instructed to follow these hygiene instructions daily and were evaluated 4 weeks later. The primary outcome measure was the degree of oral malodor with the original conventional dentures and following new denture treatment and oral hygiene instruction with 4 weeks of self-administered hygiene care. Oral malodor was expressed both quantitatively as the number of parts per billion (ppb) of volatile sulfide compounds (VSCs) and as a binary measure (present/absent) based on a threshold for oral malodor of greater than 110 ppb. Significant relationships with oral malodor (level of VSCs) at baseline with the original denture were found for education (those having only primary school education were more likely to have higher VSC level, odds ratio [OR] 8.6, P = .046), self-reported oral dryness (OR 2.5, P = .037), self-reported overnight denture wear (OR 0.342 [likely a typographical error in the table; based on the 95% CI of 1.59 to 8.35, the OR is probably 3.42], P = .002), and level of bacterial plaque coverage on

  17. Socio-Demographic and Economic Factors Affecting the Acceptance of Removable Dentures

    Science.gov (United States)

    Baran, İlgi; Ergün, Gülfem; Semiz, Mustafa

    2007-01-01

    Objectives The aim of this study was to evaluate relationships between the socio-demographic and economic factors of patients and the reasons of admission, usage periods of the two types of clinics, frequencies of denture changes, satisfaction levels and preferences of prosthetic dental treatment. Materials and Methods 510 partially and/or totally edentulous patients were studied using a questionnaire. The questionnaire consisted of questions; age, gender, education level, income status, problems with dentures, necessity for new dentures. Also asked was the place that the subjects would prefer to get their denture treatment, irrespective of their income level. In this study, Z-test was used to analyze two-sample proportions, T-test was used to determine two-sample means and Chi-square test was used to determine relationship between two classified variables. Results The number of male patients with complete dentures was more than the number of females, with an opposing trend for partial dentures. Irrespective of gender, each patient had had nearly two dentures by the time of questioning. It was also observed that the university clinics were generally preferred by patients from higher income levels with a higher educational level (x2=25.206, Pdenture treatment, regardless of cost, private practice was the preferred-choice. Conclusions With respect to dental condition and the acceptance of removable dentures, there were differences among gender, educational level and income status. PMID:19212485

  18. LINER galaxy properties and the local environment

    Science.gov (United States)

    Coldwell, Georgina V.; Alonso, Sol; Duplancic, Fernanda; Mesa, Valeria

    2018-05-01

    We analyse the properties of a sample of 5560 low-ionization nuclear emission-line region (LINER) galaxies selected from SDSS-DR12 at low red shift, for a complete range of local density environments. The host LINER galaxies were studied and compared with a well-defined control sample of 5553 non-LINER galaxies matched in red shift, luminosity, morphology and local density. By studying the distributions of galaxy colours and the stellar age population, we find that LINERs are redder and older than the control sample over a wide range of densities. In addition, LINERs are older than the control sample, at a given galaxy colour, indicating that some external process could have accelerated the evolution of the stellar population. The analysis of the host properties shows that the control sample exhibits a strong relation between colours, ages and the local density, while more than 90 per cent of the LINERs are redder and older than the mean values, independently of the neighbourhood density. Furthermore, a detailed study in three local density ranges shows that, while control sample galaxies are redder and older as a function of stellar mass and density, LINER galaxies mismatch the known morphology-density relation of galaxies without low-ionization features. The results support the contribution of hot and old stars to the low-ionization emission although the contribution of nuclear activity is not discarded.

  19. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  20. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  1. The knowledge and attitude of general dentists toward denture adhesives in Tehran

    Directory of Open Access Journals (Sweden)

    Fakhri Hamidreza

    2009-01-01

    Full Text Available Background: The purpose of this study was to generate discussion and communication among a group of general dentists in Tehran on their viewpoints regarding denture adhesives. Have they accepted denture adhesive as a material to enhance denture retention, stability and function? Materials and Methods: In the summer of 2007, a questionnaire was mailed to 300 general dentists who were assigned with a random systematic sampling method from general dentists in Tehran. The questions were arranged in two parts of evaluating knowledge and attitude. In evaluation of knowledge, dentists were classified into groups of good, moderate, weak and lack of knowledge. In evaluation of attitude, dentists were classified into positive, moderate and negative groups. (Evaluating attitude was carried out in good and moderate groups of knowledge. Results: The study showed that 14%, 32% and 37% of the general dentists had respectively good, moderate and weak knowledge toward denture adhesive while 16.3% had no knowledge about this material. In evaluation of attitude through dentists with positive and moderate knowledge toward denture adhesive, 9.3%, 71.3% and 19.4% had respectively positive, moderate and negative attitude toward denture adhesive. The χ2 test showed a significant statistical relation between situation of knowledge and experiences of dentists. Discussion: This study demonstrated that the rate of knowledge of these 300 general dentists in Tehran towards denture adhesives has not been in a good situation. It is believed that denture adhesive be able to enhance the fitness of a denture and provide psychological relief to the patient. Dentists agreed that education, not only for practitioners but also for patients, would raise the advantageous features and reduce the misuse of denture adhesive. Education of the topic "Denture adhesive" should be more concerned in dental universities.

  2. Mechanical properties of denture base resins: An evaluation

    Directory of Open Access Journals (Sweden)

    Pooran Chand

    2011-01-01

    Conclusion: The heat cure denture base material D (Trevalon "HI" was the strongest and C (Trevalon was the weakest among all materials used in this study. The study showed that the deflection of various denture base resins (A to D increases proportionately with the increase in load.

  3. Cracking investigation of Monju emergency generator C unit cylinder liner. Cylinder liner soundness confirmation by a fall cause of the materials strength of the cylinder liner and the supersonic wave speed

    International Nuclear Information System (INIS)

    Kobayashi, Takanori; Sakon, Miyoji; Takada, Osamu; Hatori, Masakazu; Sakamoto, Tsutomu; Sato, Toshiyuki; Kazama, Akihito; Ishizawa, Yoshihiro; Igawa, Katsuhisa; Nakae, Hideo

    2012-02-01

    I confirmed a leak of the effluent gas from cylinder part during a load examination after the check of the emergency generator C unit on December 28, 2010 of the facilities check average and confirmed crack in No.8 cylinder liner part. As a result, because it was not performed oil pressure management properly without attaching an oil pressure gauge when I removed cylinder liner about the cause, crack occurred by having been able to write excessive stress for the cylinder liner and reached damage. By a process of this investigation, a fall of the materials strength of some cylinder liner was confirmed, but because a lead ingredient got mixed with materials by a casting process at the time of the production of the cylinder liner, as for this, Widmannstaetten graphite occurred, and it became clear that materials strength fell. In addition, I performed inspection by the supersonic wave velocity measurement as technique to distinguish this Widmannstaetten graphite easily and confirmed that I was effective. Because this report was the knowledge that there were little inspection contents which modified soundness confirmation technique of the cylinder liner with the possibility of materials strength fall of the cylinder liner by the Widmannstaetten graphite outbreak and the mixture of lead for a report example in the field of cast iron, I gathered it in this report. (author)

  4. Candida colonization on the denture of diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Lotfi-Kamran

    2009-01-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection in diabetic patients. Presence of denture in the oral cavity of diabetic patients can promote Candida colonization and results in the higher incidence of oral and systemic candidiasis. The general purpose of the present study was to evaluate and compare Candida colonization in denture of diabetic patients and non-diabetic control group. Methods: In current case-control study, samples for mycological examinations were collected from the palatal impression surface of maxillary dentures from 92 edentulous patients including 46 dia-betic and 46 non-diabetic denture wearers. All samples were cultured directly on sabouraud agar me-dium and isolated colonies were counted and identified based on specific tests. Data were statistically analyzed using Mann-Whitney and Spearman correlation tests. Results: The higher density of isolated colonies was seen in diabetic group in compare with control group (P = 0.0001. There was a statistically significant correlation between the blood glucose level (P = 0.0001 and the duration of denture usage (P = 0.022 with the colonization of Candida on den-ture of diabetic patients. C. albicans was the most common isolated Candida species in both groups, though diabetic patients with dentures had more non-albicans Candida isolated from their dentures compared to non-diabetic patients. Conclusions: Mycological findings from the present study revealed that diabetes mellitus can in-crease colonization of Candida in denture and mouth. By elimination of local and systemic factors in diabetic patients and improving their oral health care, Candida colonization and the risk of oral and systemic candidiasis will be decreased.

  5. Color stability of different denture teeth materials: an in vitro study.

    Science.gov (United States)

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  6. Fast liner proposal

    International Nuclear Information System (INIS)

    Sherwood, A.R.; Freeman, B.L.; Gerwin, R.A.; Jarboe, T.R.; Krakowski, R.A.; Malone, R.C.; Marshall, J.; Miller, R.L.; Suydam, B.

    1977-08-01

    This is a proposal to study, both theoretically and experimentally, the possibility of making a fusion reactor by magnetically imploding a cylindrical metallic shell on a prepared plasma. The approach is characterized by the following features: (1) the nonrotating liner would be driven by an axial current, (2) the plasma would also carry an axial current that provides an azimuthal magnetic field for thermal insulation in both the radial and longitudinal directions, (3) solid end plugs would be utilized to prevent axial loss of particles, and (4) liner speeds would be in the 10 6 cm/s range. The preliminary calculations indicate (1) that the energetics are favorable (energy inputs of about 10 MJ might produce a machine in the break-even regime), (2) that radiation and heat losses could be made tolerable, (3) that alpha-particle heating could be made very effective, and (4) that Taylor instabilities in a fast liner might be harmless because of the large viscosities at high pressures. A preliminary conceptual design of the sort of fusion reactor that might result from such an approach is discussed, as are some of the relevant reactor scaling arguments

  7. Investigating oral health-related quality of life and self-perceived satisfaction with partial dentures.

    Science.gov (United States)

    Abuzar, Menaka A; Kahwagi, Esperance; Yamakawa, Takeshi

    2012-05-01

    To investigate the prevalence and severity of oral health-related quality of life in patients treated with removable partial dentures at a publicly-funded dental hospital. The association between patients' demographic profiles, denture-related, variables and oral health-related quality of life was also investigated. A questionnaire was designed to investigate the use and satisfaction of removable partial dentures, and oral health-related quality of life of removable partial denture wearers using the Oral Health Impact Profile-14. The questionnaire was administered to 740 randomly-selected patients who received removable partial dentures during 2005-2008. The response rate was 31.35%. Non-parametric tests and a logistic regression model were used to analyze the association between denture-related variables and oral health-related quality of life. A question on symptoms unrelated to dentures was also analyzed. The Oral Health Impact Profile-14 prevalence calculated was 43.1%. The removable partial denture experience and frequency of use was inversely associated with Oral Health Impact Profile-14 scores. Metal-based removable partial dentures were associated with lower Oral Health Impact Profile prevalence and severity scores. No significant association was found between demographic profile, circumstance for provision of removable partial dentures and Oral Health Impact Profile-14 score. The participants of this study indicated that perceived denture performance, removable partial dentures material, experience, and frequency of use are associated with oral health-related quality of life. © 2012 Blackwell Publishing Asia Pty Ltd.

  8. A Conventional Liner Acoustic/Drag Interaction Benchmark Database

    Science.gov (United States)

    Howerton, Brian M.; Jones, Michael G.

    2017-01-01

    The aerodynamic drag of acoustic liners has become a significant topic in the design of such for aircraft noise applications. In order to evaluate the benefits of concepts designed to reduce liner drag, it is necessary to establish the baseline performance of liners employing the typical design features of conventional configurations. This paper details a set of experiments in the NASA Langley Grazing Flow Impedance Tube to quantify the relative drag of a number of perforate-over-honeycomb liner configurations at flow speeds of M=0.3 and 0.5. These conventional liners are investigated to determine their resistance factors using a static pressure drop approach. Comparison of the resistance factors gives a relative measurement of liner drag. For these same flow conditions, acoustic measurements are performed with tonal excitation from 400 to 3000 Hz at source sound pressure levels of 140 and 150 dB. Educed impedance and attenuation spectra are used to determine the interaction between acoustic performance and drag.

  9. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    Science.gov (United States)

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture

  10. Graphical Acoustic Liner Design and Analysis Tool

    Science.gov (United States)

    Howerton, Brian M. (Inventor); Jones, Michael G. (Inventor)

    2016-01-01

    An interactive liner design and impedance modeling tool comprises software utilized to design acoustic liners for use in constrained spaces, both regularly and irregularly shaped. A graphical user interface allows the acoustic channel geometry to be drawn in a liner volume while the surface impedance calculations are updated and displayed in real-time. A one-dimensional transmission line model may be used as the basis for the impedance calculations.

  11. The effect of various factors on the masticatory performance of removable denture wearer

    Science.gov (United States)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  12. SDU6 Interior Liner Testing & Evaluation

    International Nuclear Information System (INIS)

    Skidmore, T. E.

    2016-01-01

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  13. Quantitative Analysis of Retrieved Glenoid Liners

    Directory of Open Access Journals (Sweden)

    Katelyn Childs

    2016-02-01

    Full Text Available Revision of orthopedic surgeries is often expensive and involves higher risk from complications. Since most total joint replacement devices use a polyethylene bearing, which serves as a weak link, the assessment of damage to the liner due to in vivo exposure is very important. The failures often are due to excessive polyethylene wear. The glenoid liners are complex and hemispherical in shape and present challenges while assessing the damage. Therefore, the study on the analysis of glenoid liners retrieved from revision surgery may lend insight into common wear patterns and improve future product designs. The purpose of this pilot study is to further develop the methods of segmenting a liner into four quadrants to quantify the damage in the liner. Different damage modes are identified and statistically analyzed. Multiple analysts were recruited to conduct the damage assessments. In this paper, four analysts evaluated nine glenoid liners, retrieved from revision surgery, two of whom had an engineering background and two of whom had a non-engineering background. Associated human factor mechanisms are reported in this paper. The wear patterns were quantified using the Hood/Gunther, Wasielewski, Brandt, and Lombardi methods. The quantitative assessments made by several observers were analyzed. A new, composite damage parameter was developed and applied to assess damage. Inter-observer reliability was assessed using a paired t-test. Data reported by four analysts showed a high standard deviation; however, only two analysts performed the tests in a significantly similar way and they had engineering backgrounds.

  14. SDU6 Interior Liner Testing & Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Skidmore, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-14

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  15. Broadband Liner Optimization for the Source Diagnostic Test Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2012-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more appealing. This paper describes a broadband acoustic liner optimization study for the scale model Source Diagnostic Test fan. Specifically, in-duct attenuation predictions with a statistical fan source model are used to obtain optimum impedance spectra over a number of flow conditions for three liner locations in the bypass duct. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Typical tonal liner designs targeting single frequencies at one operating condition are first produced to provide baseline performance information. These are followed by multiple broadband design approaches culminating in a broadband liner targeting the full range of frequencies and operating conditions. The broadband liner is found to satisfy the optimum impedance objectives much better than the tonal liner designs. In addition, the broadband liner is found to provide better attenuation than the tonal designs over the full range of frequencies and operating conditions considered. Thus, the current study successfully establishes a process for the initial design and evaluation of novel broadband liner concepts for complex engine configurations.

  16. Factors influencing patients’ satisfaction with complete dentures: a qualitative study.

    OpenAIRE

    Silva, Jessica de Cassia Motta; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; dos Santos, Jarbas Francisco Fernandes; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; Marchini, Leonardo; College of Dentistry – University of Iowa – Iowa City – IA – USA.

    2014-01-01

    Objective: The treatment most used worldwide for edentulism is conventional complete dentures, and the most important factor for the success of denture treatment seems to be patient satisfaction. The present study aims to use a qualitative approach to investigate factors that were previously associated with patient satisfaction with dentures by quantitative techniques (correlational studies). Material and methods: Twenty patients (12 women and 8 men, age 59-87) participated in open and semi-s...

  17. Thermographic inspection of pipes, tanks, and containment liners

    Energy Technology Data Exchange (ETDEWEB)

    Renshaw, Jeremy B., E-mail: jrenshaw@epri.com; Muthu, Nathan [Electric Power Research Institute, 1300 West WT Harris Blvd., Charlotte, NC 28262 (United States); Lhota, James R.; Shepard, Steven M., E-mail: sshepard@thermalwave.com [Thermal Wave Imaging, 845 Livernois St., Ferndale, MI 48220 (United States)

    2015-03-31

    Nuclear power plants are required to operate at a high level of safety. Recent industry and license renewal commitments aim to further increase safety by requiring the inspection of components that have not traditionally undergone detailed inspected in the past, such as tanks and liners. NEI 09-14 requires the inspection of buried pipes and tanks while containment liner inspections are required as a part of license renewal commitments. Containment liner inspections must inspect the carbon steel liner for defects - such as corrosion - that could threaten the pressure boundary and ideally, should be able to inspect the surrounding concrete for foreign material that could be in contact with the steel liner and potentially initiate corrosion. Such an inspection requires a simultaneous evaluation of two materials with very different material properties. Rapid, yet detailed, inspection results are required due to the massive size of the tanks and containment liners to be inspected. For this reason, thermal NDE methods were evaluated to inspect tank and containment liner mockups with simulated defects. Thermographic Signal Reconstruction (TSR) was utilized to enhance the images and provide detailed information on the sizes and shapes of the observed defects. The results show that thermographic inspection is highly sensitive to the defects of interest and is capable of rapidly inspecting large areas.

  18. 21 CFR 872.3250 - Calcium hydroxide cavity liner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calcium hydroxide cavity liner. 872.3250 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3250 Calcium hydroxide cavity liner. (a) Identification. A calcium hydroxide cavity liner is a device material intended to be applied to the interior of a...

  19. Modular liquid-cooled helmet liner for thermal comfort

    Science.gov (United States)

    Williams, B. A.; Shitzer, A.

    1974-01-01

    A modular liquid-cooled helmet liner made of eight form-fitting neoprene patches was constructed. The liner was integrated into the sweatband of an Army SPH-4 helicopter aircrew helmet. This assembly was tested on four subjects seated in a hot (47 C), humid (40%) environment. Results indicate a marked reduction in the rate of increase of physiological body functions. Rectal temperature, weight loss, heart rate, and strain indices are all reduced to approximately 50% of uncooled levels. The cooling liner removed from 10% to 30% of total metabolic heat produced. This study also demonstrated the technical feasilibity of using a cooling liner in conjunction with a standard hard helmet. Potential applications of the cooling liner in thermally stressful environments are numerous, notably for helicopter and other aircrews.

  20. Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.

    Science.gov (United States)

    ELsyad, Moustafa Abdou; Errabti, Hatem Mokhtar; Mustafa, Aisha Zakaria

    2016-12-01

    The aim of this in vitro study was to evaluate and compare mandibular denture base deformation between ball and Locator attachments of implant-retained overdentures. An experimental acrylic model covered with resilient silicone mucosal simulation was constructed. Two laboratory implants were placed in the canine areas of the model. Two duplicate experimental overdentures were constructed and connected to the implants with either ball (GI) or Locator (GII) attachments. To measure overdenture strain around the attachments, 3 strain gauges were attached to the lingual polished surface of the overdentures opposite to the right implant (loading side) 2 mm above the attachment level (Ch1), at the attachment level (Ch2), and 2 mm below the attachment level (Ch3). Another 3 gauges were bonded opposite to the left implant (non-loading side) in the same manner (Ch6, Ch7, and Ch8). To measure strain at the midline of the overdentures, two strain gauges were attached in the midline at 5 mm intervals (Ch4 and Ch5). A universal testing device was used to deliver vertical static load of 50 N unilaterally and bilaterally to the first molar area to measure strain using a multi-channel digital strain meter. During bilateral load application, GII recorded higher compressive strains than GI at the majority of channels. During unilateral load application, GI recorded higher tensile strains at Ch1, Ch2, and Ch3, and GII recorded higher strains than GI at Ch6, Ch7, and Ch8. During bilateral loading the highest strain was concentrated at Ch5 for both groups. During unilateral loading, the highest strain was concentrated at Ch2 for GI, and at Ch5 for GII. Ball attachments for implant-retained overdentures were associated with significant mandibular denture base deformation over the implants compared to Locator attachments. Therefore, denture base reinforcement may be recommended with ball attachmentz to increase fracture resistance of the base. © 2015 by the American College of

  1. Functional Impressions in Complete Denture and Overdenture Treatment

    Directory of Open Access Journals (Sweden)

    Hrvoje Kršek

    2015-01-01

    Full Text Available Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions.

  2. Isolation of Candida species from the oral cavity and fingertips of complete denture wearers.

    Science.gov (United States)

    Nagaral, Suresh; Desai, Raviraj G; Kamble, Vikas; Patil, Anand Kumar G

    2014-11-01

    Wearing a dental prosthesis is known to increase oral candidal colonization and predispose the wearer to oral candidosis. Denture wearers frequently use fingers to take the prosthesis out of their mouth. Oral Candida, if present may contaminate wearer's finger. The objective of this study was to investigate the simultaneous candidal colonization of oral cavity and fingertips of complete denture wearers. A total of 25 apparently healthy male subjects who had worn complete dentures for at least 1 year were selected. Information about each patient's denture age, denture hygiene, handling, and wearing habits, and hand washing habits after denture handling were be obtained. Intraoral examination of all the patients was done. For microbiological examination samples were collected from the fingertip and oral rinse of each patient. Candida species were identified with use of germ tube test and commercially available yeast identification system. Data was statistically analyzed. Significance was set at p < 0.05. It was found that frequency of hand washing, denture handling and denture stomatitis with respect to fingertip candidal isolation was not statistically significant. But poor denture hygiene and denture stomatitis with respect to oral candidal colonization was statistically significant. Denture wearers with oral Candida had a higher prevalence of Candida contamination on their fingers. Patients with removable prostheses should be informed about the importance of proper prosthesis and personal hygiene and the possibility of microbial contamination of the hands and other parts of the body.

  3. Diagnostics for the Plasma Liner Experiment

    International Nuclear Information System (INIS)

    Lynn, A. G.; Merritt, E.; Gilmore, M.; Hsu, S. C.; Witherspoon, F. D.; Cassibry, J. T.

    2010-01-01

    The goal of the Plasma Liner Experiment (PLX) is to explore and demonstrate the feasibility of forming imploding spherical ''plasma liners'' via merging high Mach number plasma jets to reach peak liner pressures of ∼0.1 Mbar using ∼1.5 MJ of initial stored energy. Such a system would provide HED plasmas for a variety of fundamental HEDLP, laboratory astrophysics, and materials science studies, as well as a platform for experimental validation of rad-hydro and rad-MHD simulations. It could also prove attractive as a potential standoff driver for magnetoinertial fusion. Predicted parameters from jet formation to liner stagnation cover a large range of plasma density and temperature, varying from n i ∼10 16 cm -3 , T e ≅T i ∼1 eV at the plasma gun mouth to n i >10 19 cm -3 , T e ≅T i ∼0.5 keV at stagnation. This presents a challenging problem for the plasma diagnostics suite which will be discussed.

  4. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    Science.gov (United States)

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  5. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    Science.gov (United States)

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (Padhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014

  6. Leaching from denture base materials in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Lygre, H.; Solheim, E.; Gjerdet, N.R. [School of Medicine, Univ. of Bergen (Norway)

    1995-04-01

    Specimens made from denture base materials were leached in Ringer Solution and in ethanol. The specimens comprised a heat-cured product processed in two different ways and two cold-cured materials. The organic compounds leaching from the specimens to the solutions were separated, identified, and quantified by a combined gas-chromatography and gas-chromatography/mass-spectrometry technique. Additives and degradation products, possibly made by free radical reactions, were released from the denture base materials. In Ringer solution only phthalates could be quantified. In ethanol solvent, biphenyl, dibutyl phthalate, dicyclohexyl phthalate, phenyl benzoate, and phenyl salicylate were quantified. In addition, copper was found in the ethanol solvent from one of the denture base materials. The amount of leachable organic compounds varies among different materials. Processing temperature influences the initial amount of leachable compounds. 36 refs., 7 figs., 1 tab.

  7. A Randomised Controlled Trial of complete denture impression materials

    Science.gov (United States)

    Hyde, T.P.; Craddock, H.L.; Gray, J.C.; Pavitt, S.H.; Hulme, C.; Godfrey, M.; Fernandez, C.; Navarro-Coy, N.; Dillon, S.; Wright, J.; Brown, S.; Dukanovic, G.; Brunton, P.A.

    2014-01-01

    Objectives There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Methods Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Results Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7–67.3%, p alginate as their material of choice for secondary impressions for complete dentures. Trial Registration: ISRCTN 01528038.

 This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. PMID:24995473

  8. Generation of a rotating liquid liner by tangential injection

    International Nuclear Information System (INIS)

    Burton, R.L.; Turchi, P.J.; Jenkins, D.J.; Lanham, R.E.; Cameron, J.; Cooper, A.L.

    1979-01-01

    Efficient compression of low mass-density payloads by the implosion of higher mass-density liquid cylinders or liners, as in the NRL LINUS concept for controlled thermonuclear fusion, requires rotation of the liner material to avoid Rayleigh--Taylor instabilities at the liner-payload interface. Experimentally, such implosions have been demonstrated with liners formed within rotating implosion chambers. The present work uses a scale-model experimental apparatus to investigate the possibility of creating liner rotation by tangential injection of the liquid liner material. Different modes of behavior are obtained depending on the fluid exhaust procedures. Right-circular, cylindrical free surfaces are achieved with axial exhaust of fluid at radii interior to the injection nozzles, for which the liner exhibits a combination of solid-body and free vortex flows in different regions. Measurements allow estimates of power losses to viscous shear, turbulence, etc. A simple model based on open-channel flow is then derived, which is in good agreement with experiment, and is used to extrapolate results to the scale of a possible LINUS fusion reactor

  9. Temporary abandonment cement plug on the liner top; Tampao de abandono temporario na boca do liner

    Energy Technology Data Exchange (ETDEWEB)

    Hiss Filho, Paulo Henrique; Costa Junior, Pedro Americo da; Viana, Jose Luis Rodrigues [PETROBRAS, Rio de Janeiro, RJ (Brazil). Distrito de Pefuracao do Sudeste. Div. de Tecnicas de Perfuracao

    1994-07-01

    In many instances wells are temporary abandoned just after cementing liner to be completed later or to have the BOP removed to change rams. In these cases, an additional volume of slurry is designed in order to bring the top of cement plug over the liner top, thus saving the time required for all full plugging operation. (author)

  10. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report

    OpenAIRE

    Hazari, Puja; Mishra, Sunil Kumar

    2015-01-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section ov...

  11. Liquid metal liner implosion systems with blade lattice for fusion

    International Nuclear Information System (INIS)

    Itoh, Yasuyuki; Fujiie, Yoichi

    1980-01-01

    In this paper, the liquid liner implosion systems with the blade lattice is proposed for the rotational stabilization of the liner inner surface which is facing a plasma in a fusion reactor. The blades are electrically conducting and inclined to the radial direction. Its major function is either acceleration or deceleration of the liner in the azimuthal direction. This system enables us to exclude the rotary mechanism for the liner rotation. In this system, the liner is formed as an annular flow of a liquid metal (the waterfall concept). Results show that there is no significant difference of the energy cost for the stabilization compared with the earlier proposed system where a liner is rotated rigidly before implosion. Furthermore, the application of the rotating blade lattice makes it possible to reduce the rotational kinetic energy required for the stabilization at turnaround, where the lattice acts as an impeller in the initial liner rotation. There is an optimum blade angle to maximize the compressed magnetic field energy inside the liner for a given driving energy. (author)

  12. Removable partial dentures: use of rapid prototyping.

    Science.gov (United States)

    Lima, Julia Magalhaes Costa; Anami, Lilian Costa; Araujo, Rodrigo Maximo; Pavanelli, Carlos A

    2014-10-01

    The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures. © 2014 by the American College of Prosthodontists.

  13. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks.

    Science.gov (United States)

    Norvell, Nicholas G; Korioth, Tom V; Cagna, David R; Versluis, Antheunis

    2018-02-08

    Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were

  14. Evaluation of Skin Friction Drag for Liner Applications in Aircraft

    Science.gov (United States)

    Gerhold, Carl H.; Brown, Martha C.; Jasinski, Christopher M.

    2016-01-01

    A parameter that is gaining significance in the evaluation of acoustic liner performance is the skin friction drag induced by air flow over the liner surface. Estimates vary widely regarding the amount of drag the liner induces relative to a smooth wall, from less than a 20% increase to nearly 100%, and parameters such as face sheet perforate hole diameter, percent open area, and sheet thickness are expected to figure prominently in the skin friction drag. Even a small increase in liner drag can impose an economic penalty, and current research is focused on developing 'low drag' liner concepts, with the goal being to approach the skin friction drag of a smooth wall. The issue of skin friction drag takes on greater significance as airframe designers investigate the feasibility of putting sound absorbing liners on the non-lifting surfaces of the wings and fuselage, for the purpose of reducing engine noise reflected and scattered toward observers on the ground. Researchers at the NASA Langley Research Center have embarked on investigations of liner skin friction drag with the aims of: developing a systematic drag measurement capability, establishing the drag of current liners, and developing liners that produce reduced drag without compromising acoustic performance. This paper discusses the experimental procedures that have been developed to calculate the drag coefficient based on the change in momentum thickness and the companion research program being carried out to measure the drag directly using a force balance. Liner samples that are evaluated include a solid wall with known roughness and conventional liners with perforated facesheets of varying hole diameter and percent open area.

  15. CANMET Gasifier Liner Coupon Material Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Mark Fitzsimmons; Dave Grimmett; Bryan McEnerney

    2007-01-31

    This report provides detailed test results consisting of test data and post-test inspections from Task 1 ''Cooled Liner Coupon Development and Test'' of the project titled ''Development of Technologies and Capabilities for Coal Energy Resources--Advanced Gasification Systems Development (AGSD)''. The primary objective of this development and test program is to verify that ceramic matrix composite (CMC) liner materials planned for use in an advanced gasifier pilot plant will successfully withstand the environments in a commercial gasifier. Pratt & Whitney Rocketdyne (PWR) designed and fabricated the cooled liner test assembly article that was tested in a slagging gasifier at CANMET Energy Technology Center (CETC-O) in Ottawa, Ontario, Canada. The test program conducted in 2006 met the objective of operating the cooled liner test article at slagging conditions in a small scale coal gasifier at CETC-O for over the planned 100 hours. The test hardware was exposed to at least 30 high temperature excursions (including start-up and shut-down cycles) during the test program. The results of the testing has provided valuable information on gasifier startup and required cooling controls in steady state operation of future advanced gasifiers using similar liners. The test program also provided a significant amount of information in the areas of CMC materials and processing for improved capability in a gasifier environment and insight into CMC liner fabrication that will be essential for near-term advanced gasifier projects.

  16. Diagnostics for the plasma liner experiment.

    Science.gov (United States)

    Lynn, A G; Merritt, E; Gilmore, M; Hsu, S C; Witherspoon, F D; Cassibry, J T

    2010-10-01

    The goal of the Plasma Liner Experiment (PLX) is to explore and demonstrate the feasibility of forming imploding spherical "plasma liners" via merging high Mach number plasma jets to reach peak liner pressures of ∼0.1 Mbar using ∼1.5 MJ of initial stored energy. Such a system would provide HED plasmas for a variety of fundamental HEDLP, laboratory astrophysics, and materials science studies, as well as a platform for experimental validation of rad-hydro and rad-MHD simulations. It could also prove attractive as a potential standoff driver for magnetoinertial fusion. Predicted parameters from jet formation to liner stagnation cover a large range of plasma density and temperature, varying from n(i)∼10(16) cm(-3), T(e)≈T(i)∼1 eV at the plasma gun mouth to n(i)>10(19) cm(-3), T(e)≈T(i)∼0.5 keV at stagnation. This presents a challenging problem for the plasma diagnostics suite which will be discussed.

  17. Alveolar ridge rehabilitation to increase full denture retention and stability

    Directory of Open Access Journals (Sweden)

    Mefina Kuntjoro

    2010-12-01

    Full Text Available Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augmentation and vestibuloplasty was aimed to provide stability and retentive denture atrophic mandibular alveolar ridge. Case: A 65 years old woman patient complained about uncomfortable denture. Clinical evaluate showed flat ridge in the anterior mandible, flabby tissue and candidiasis, while residual ridge height was classified into class IV. Case management: Augmentation using autograph was conducted as the mandible vertical height is less than 15 mm. Autograph was used to achieve better bone quantity and quality. Separated alveolar ridge was conducted from left to right canine region and was elevated 0.5 mm from the previous position to get new ridge in the anterior region. The separated alveolar ridge was fixated by using T-plate and ligature wire. Three months after augmentation fixation appliances was removed vestibuloplasty was performed to increase denture bearing area that can make a stable and retentive denture. Conclusion: Augmentation and vestibuloplasty can improve flat ridge to become prominent.Latar belakang: Ridge mandibula yang atrofi pada umumnya mempersulit pembuatan restorasi prostetik terutama gigi tiruan lengkap (GTL. Residual alveolar ridge dan basal seat yang rendah menyebabkan gigi tiruan menjadi tidak stabil, menimbulkan ulser permanen, nyeri, neuralgia, dan kesulitan mengunyah. Tujuan: Augmentasi dan vestibuloplasti pada ridge mandibula yang atrofi dilakukan untuk menciptakan gigi tiruan yang stabil dan retentive. Kasus: Pasien wanita

  18. In-situ studies on the performance of landfill caps (compacted soil liners, geomembranes, geosynthetic clay liners, capillary barriers)

    International Nuclear Information System (INIS)

    Melchior, S.

    1997-01-01

    Since 1986 different types of landfill covers have been studied in-situ on the Georgswerder landfill in Hamburg, Germany. Water balance data are available for eight years. The performance of different carriers has been measured by collecting the leakage on areas ranging from 100 m 2 to 500 m 2 . Composite liners with geomembranes performed best, showing no leakage. An extended capillary barrier also performed well. The performance of compacted soil liners, however, decreased severely within five years due to desiccation, shrinkage and plant root penetration (liner leakage now ranging from 150 mm/a to 200 mm/a). About 50 % of the water that reaches the surface of the liner is leaking through it. The maximum leakage rates have increased from 2 x 10 -10 m 3 m -2 s -1 to 4 x 10 -8 m 3 m -2 s -1 . Two types of geosynthetic clay liners (GCL) have been tested for two years now with disappointing results. The GCL desiccated during the first dry summer of the study. High percolation rates through the GCL were measured during the following winter (45 mm resp. 63 mm in four months). Wetting of the GCL did not significantly reduce the percolation rates

  19. A randomised controlled trial of complete denture impression materials.

    Science.gov (United States)

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, pUnilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. The photoionization mechanism of LINERs - Stellar and nonstellar

    Science.gov (United States)

    Ho, Luis C.; Filippenko, Alexei V.

    1993-01-01

    We present high quality spectroscopic observations of a sample of 14 LINERs. Starlight removal is achieved by the subtraction of a suitable absorption-line 'template' galaxy, allowing accurate measurements of emission lines. We use these line fluxes to examine the possible excitation mechanisms of LINERs. We suggest that LINERs with weak forbidden O I 6300-A emission may be H II regions photoionized by unusually hot O-type stars. LINERs with forbidden O I/H-alpha approximately greater than 1/6 may be powered by photoionization from a nonstellar continuum. This is supported by the detection of broad H-alpha emission, a correlation between line width and critical density, and pointlike X-ray emission in several of these objects.

  1. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Science.gov (United States)

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  2. Evaluation of Novel Liner Concepts for Fan and Airframe Noise Reduction

    Science.gov (United States)

    Jones, M. G.; Howerton, B. M.

    2016-01-01

    This paper presents a review of four novel liner concepts: soft vanes, over-the-rotor liners, external liners, and flap side-edge liners. A number of similarities in the design and evaluation of these concepts emerged during these investigations. Since these were the first attempts to study these particular liner concepts, there was limited information to guide the design process. In all cases, the target frequencies (or frequency range) were known, but the optimum acoustic impedance and optimum liner placement were typically not known. For these cases, the maximum available surface was used and a c-impedance was targeted based on the assumption the sound field impinges on the surface at normal incidence. This choice proved fruitful for every application. An impedance prediction model was used to design variable-depth liner configurations, and a graphical design code (ILIAD) was developed to aid in this process. The ability to build increasingly complex liner configurations via additive manufacturing was key, such that multiple designs could quickly be tested in a normal incidence impedance tube. The Two-Thickness Method was used to evaluate available bulk materials, such that bulk liners could also be considered for each application. These novel liner concepts provide sufficient noise reduction to warrant further investigations.

  3. The oral microbiome of denture wearers is influenced by levels of natural dentition

    NARCIS (Netherlands)

    O'Donnell, L.E.; Robertson, D.; Nile, C.J.; Cross, L.J.; Riggio, M.; Sherriff, A.; Bradshaw, D.; Lambert, M.; Malcolm, J.; Buijs, M.J.; Zaura, E.; Crielaard, W.; Brandt, B.W.; Ramage, G.

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to

  4. 49 CFR 193.2187 - Nonmetallic membrane liner.

    Science.gov (United States)

    2010-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS Design Lng Storage Tanks § 193.2187 Nonmetallic membrane liner. A flammable nonmetallic membrane liner may not be used as an inner container in a storage tank...

  5. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    Science.gov (United States)

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  6. Oral manifestations of diabetes mellitus in complete denture wearers.

    Science.gov (United States)

    Cristina de Lima, Danielle; Nakata, Gislaine Cristina; Balducci, Ivan; Almeida, Janete Dias

    2008-01-01

    The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.

  7. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age

    Directory of Open Access Journals (Sweden)

    Bharathi Prakash

    2015-01-01

    Full Text Available Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud′s dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.

  8. Stress analysis of liners for prestressed concrete reactor pressure vessels with regard to non-linear behaviour of liner material and of anchor-characteristics

    International Nuclear Information System (INIS)

    Oberpichler, R.; Schnellenbach, G.

    1975-01-01

    The thin liner attached by anchors like a membrane to the interior wall of a prestressed concrete reactor pressure vessel (PCRV) has to provide the leak-tightness of the vessel. Furthermore the liner may serve as internal shuttering for placing of concrete as well as a support for the cooling system. The two-dimensional behaviour of the liner is investigated with regard to non-linear anchor-characteristics and non-linear material behaviour of the liner. The analysis is based on a plane stress model under the assumption of a membrane state of the liner. Calculations are performed by the dynamic relaxation method. With the aid of available non-linear stress-strain diagrams, describing the post-buckling behaviour, individual panels are considered as buckled ones. The adjacent unbuckled panels are calculated on other non-linear diagrams. Strains and stresses in the liner and additional shear loads in the anchors can be calculated with arbitrary sizing and spacing of the anchors. With respect to the parameters they are easily controlled. Since actual loads on the liner are defined by the PCRV-behaviour, an economical and safe design is possible. Finally an extreme case is calculated to assess the maximum value of the shear-forces assuming zero post-buckling capacity for the buckled panel. (Auth.)

  9. Development of chair-side evaluation system of swallowing discomfort of denture wearers

    Science.gov (United States)

    Matsumoto, Keisuke; Ikuta, Ryuhei; Kataoka, Kanako; Ono, Yumie; Tamaki, Katsushi

    2018-02-01

    We investigated the appropriate hemodynamic parameters of functional near-infrared spectroscopy (fNIRS) to best differentiate the discomfort intensity related to swallowing in healthy subjects wearing different types of simulated dentures. Thirty-one subjects performed 4 sessions of water-swallowing task in a sitting position without or with wearing any one of the 3 simulated dentures under continuous fNIRS monitoring of the prefrontal cortex. The simulated dentures were consisted of a flat maxillary palatal bar and bilateral support attachment to the teeth and gum. The palatal bar positions were arranged along with the anterior, middle, or posterior areas of the upper jaw. The cumulative values of oxyhemoglobin and deoxyhemoglobin concentration changes were calculated for periods of 5 - 10 s from completion of swallowing. Subjective rating of swallowing-discomfort was the lowest without wearing denture and increased along with the palatal bar position placed from anterior to posterior. Cumulated deoxyhemoglobin signals calculated for 10 s post-swallowing event in the left frontopolar prefrontal cortex showed the best correlation with the subjective rating of discomfort in swallowing with dentures. These neurological signatures would be beneficial to detect swallowing discomfort in elderly denture wearers who have difficulty in communicating with dentists.

  10. Design and modeling of precision solid liner experiments on Pegasus

    International Nuclear Information System (INIS)

    Bowers, R.L.; Brownell, J.H.; Lee, H.; McLenithan, K.D.; Scannapieco, A.J.; Shanahan, W.R.

    1998-01-01

    Pulsed power driven solid liners may be used for a variety of physics experiments involving materials at high stresses. These include shock formation and propagation, material strain-rate effects, material melt, instability growth, and ejecta from shocked surfaces. We describe the design and performance of a cylindrical solid liner that can attain velocities in the several mm/μs regime, and that can be used to drive high-stress experiments. An approximate theoretical analysis of solid liner implosions is used to establish the basic parameters (mass, materials, and initial radius) of the driver. We then present one-dimensional and two-dimensional simulations of magnetically driven, liner implosions which include resistive heating and elastic endash plastic behavior. The two-dimensional models are used to study the effects of electrode glide planes on the liner close-quote s performance, to examine sources of perturbations of the liner, and to assess possible effects of instability growth during the implosion. Finally, simulations are compared with experimental data to show that the solid liner performed as predicted computationally. Experimental data indicate that the liner imploded from an initial radius of 2.4 cm to a target radius of 1.5 cm, and that it was concentric and cylindrical to better than the experimental resolution (60 μm) at the target. The results demonstrate that a precision solid liner can be produced for high-stress, pulsed power applications experiments. copyright 1998 American Institute of Physics

  11. Development of a Multifidelity Approach to Acoustic Liner Impedance Eduction

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2017-01-01

    The use of acoustic liners has proven to be extremely effective in reducing aircraft engine fan noise transmission/radiation. However, the introduction of advanced fan designs and shorter engine nacelles has highlighted a need for novel acoustic liner designs that provide increased fan noise reduction over a broader frequency range. To achieve aggressive noise reduction goals, advanced broadband liner designs, such as zone liners and variable impedance liners, will likely depart from conventional uniform impedance configurations. Therefore, educing the impedance of these axial- and/or spanwise-variable impedance liners will require models that account for three-dimensional effects, thereby increasing computational expense. Thus, it would seem advantageous to investigate the use of multifidelity modeling approaches to impedance eduction for these advanced designs. This paper describes an extension of the use of the CDUCT-LaRC code to acoustic liner impedance eduction. The proposed approach is applied to a hardwall insert and conventional liner using simulated data. Educed values compare well with those educed using two extensively tested and validated approaches. The results are very promising and provide justification to further pursue the complementary use of CDUCT-LaRC with the currently used finite element codes to increase the efficiency of the eduction process for configurations involving three-dimensional effects.

  12. The effect of a commercial probiotic drink on oral microbiota in healthy complete denture wearers

    Directory of Open Access Journals (Sweden)

    Justyna Sutula

    2012-10-01

    Full Text Available Background : It is acknowledged that oral and general health status declines with age. The global population of denture wearers is increasing, so is the incidence of denture biofilm-related problems, such as denture-associated stomatitis, aspiration pneumonia and malodour. It has been suggested that consumption of probiotic bacteria may improve oral health. However, the effects of probiotics on the oral microbiota of denture wearers have received little attention. Methods : The aim of this study was to investigate the effect of consumption of a commercial probiotic product (Yakult on microbiota of saliva, tongue and denture biofilm in healthy complete denture wearers. Eight healthy complete denture-wearing National Health Service (NHS patients undertook a 7-week trial comprising three phases: baseline; 4-week consumption of one bottle of Yakult per day, each containing a minimum 6.5×109 viable cells of Lactobacillus casei strain Shirota (LcS; 4-week washout period. The microbial viability and composition of saliva, tongue dorsum coating and denture biofilm were assessed using a range of solid selective and indicator media. Questionnaires were used to explore participants’ denture cleaning habits and impact of wearing dentures on their life quality and well-being [modified oral health impact profile (OHIP-14] prior to and after the study. Results : Seven volunteers (1 male, 6 females completed the trial. LcS temporarily colonised oral cavity and denture surface. There was no significant change in the viability of Streptococcus mutans, acidogenic microorganisms, total anaerobic species and Gram-negative obligate anaerobes between study phases. There was no obvious effect of LcS on occurrence and viability of Candida. Participants presented a good general knowledge of denture hygiene and their responses to OHIP-14 questionnaires improved after completing the study (p=0.16. Conclusion : It appeared that 4-week consumption of probiotic drink had

  13. [Longitudinal survey and analysis among Chengdu residents on cognition and acceptance of implant dentures].

    Science.gov (United States)

    Zuo, Yanping; Wang, Yongyue; Wang, Luming; Du, Bing

    2014-08-01

    This study aims to survey the cognition and acceptance of implant dentures among Chengdu residents in 2005 and 2013 and to comparatively analyze the differences and influencing factors. A questionnaire was designed for this study. Its main content included basic demographics of respondents (gender, age, cultural level, and income level), cognition level of implant dentures (concept and main characteristics of implant dentures), main concern of respondents regarding implant dentures and medical institutions, and acceptance level of the price of implant dentures, among others. The sampling survey was carried out among Chengdu residents in 2005 and 2013 using the designed questionnaire. The results were then statistically analyzed. Up to 908 valid questionnaires in 2005 and 905 valid questionnaires in 2013 were obtained. The level of cognition of implant dentures was higher in 2013 than in 2005, and the correlation between cognition and cultural level and that between cognition and income level were both positive. However, the correlation between cognition and age was negative. The success rate for implant dentures and medical treatment technology of medical institutions were the factors that the respondents were mainly concerned with. The main methods for disseminating information on implant dentures were the internet, television, newspapers, magazines, and introduction by friends. With the development of the society's economy and the improvement of culture and income level of Chengdu residents, the cognition and acceptance level of implant dentures have gradualy increased. Meanwhile, health education and medical technology still need to be strengthened.

  14. Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency

    Directory of Open Access Journals (Sweden)

    Rachel Gomes CARDOSO

    Full Text Available Abstract The aim of this non-randomized controlled clinical trial was to evaluate the oral health-related quality of life and masticatory efficiency of patients rehabilitated with mandibular two-implant overdentures with immediate loading or conventional dentures. Fifty completely edentulous patients wearing bimaxillary conventional dentures, for at least one year, were recruited. The patients were then assigned to either two treatment groups: mandibular overdentures supported by two implants with bar-clip system and a maxillary conventional denture (n = 25, and new maxillary and mandibular conventional complete dentures (n = 25. Masticatory efficiency and oral health-related quality of life were assessed before and 3 months after denture insertion. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral health-related quality of life. Masticatory efficiency was evaluated with chewing capsules through a colorimetric method. The results revealed fewer oral health–related quality of life problems in patients wearing mandibular two-implant overdentures compared to the conventional dentures group. In addition, the implant overdenture group presented statistically significant improvement in masticatory efficiency (p = 0.001. There was no correlation between masticatory efficiency and OHIP in the implant group (p > 0.05, however a correlation was found in the conventional denture group (p < 0.05. Therefore, these short-term results suggest that mandibular overdenture retained by 2 implants with immediate loading combined with maxillary conventional dentures provide better masticatory efficiency and oral health–related quality of life than mandibular conventional dentures.

  15. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    Science.gov (United States)

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  16. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report.

    Science.gov (United States)

    Hazari, Puja; Mishra, Sunil Kumar

    2015-08-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section over the anterior knife-edge ridge. The weight provided retention and stability while the hollow portion prevented further resorption of the bone.

  17. The magnetically driven imploding liner parameter space of the ATLAS capacitor bank

    CERN Document Server

    Lindemuth, I R; Faehl, R J; Reinovsky, R E

    2001-01-01

    Summary form only given, as follows. The Atlas capacitor bank (23 MJ, 30 MA) is now operational at Los Alamos. Atlas was designed primarily to magnetically drive imploding liners for use as impactors in shock and hydrodynamic experiments. We have conducted a computational "mapping" of the high-performance imploding liner parameter space accessible to Atlas. The effect of charge voltage, transmission inductance, liner thickness, liner initial radius, and liner length has been investigated. One conclusion is that Atlas is ideally suited to be a liner driver for liner-on-plasma experiments in a magnetized target fusion (MTF) context . The parameter space of possible Atlas reconfigurations has also been investigated.

  18. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components.

    Science.gov (United States)

    Jiao, T; Chang, T; Caputo, A A

    2009-03-01

    To photoelastically examine load transfer by unilateral distal extension removable partial dentures with supporting and retentive components made of the lower stiffness polyacetal resins. A mandibular photoelastic model, with edentulous space distal to the right second premolar and missing the left first molar, was constructed to determine the load transmission characteristics of a unilateral distal extension base removable partial denture. Individual simulants were used for tooth structure, periodontal ligament, and alveolar bone. Three designs were fabricated: a major connector and clasps made from polyacetal resin, a metal framework as the major connector with polyacetal resin clasp and denture base, and a traditional metal framework I-bar removable partial denture. Simulated posterior bilateral and unilateral occlusal loads were applied to the removable partial dentures. Under bilateral and left side unilateral loading, the highest stress was observed adjacent to the left side posterior teeth with the polyacetal removable partial denture. The lowest stress was seen with the traditional metal framework. Unilateral loads on the right edentulous region produced similar distributed stress under the denture base with all three designs but a somewhat higher intensity with the polyacetal framework. The polyacetal resin removable partial denture concentrated the highest stresses to the abutment and the bone. The traditional metal framework I-bar removable partial denture most equitably distributed force. The hybrid design that combined a metal framework and polyacetal clasp and denture base may be a viable alternative when aesthetics are of primary concern.

  19. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Directory of Open Access Journals (Sweden)

    N. H. J. Creugers

    2010-01-01

    Full Text Available Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n=25 were compared with subjects with shortened dental arches without extension (n=74 and with subjects who had worn a mandibular extension removable partial denture in the past (n=19. Subjects with complete dentitions (n=72 were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function.

  20. Provision of a swing lock denture for a patient with Gorlin Goltz syndrome.

    Science.gov (United States)

    Razaq, I; Durey, K; Nattress, B

    2012-09-01

    Swinglock dentures are used relatively infrequently but in cases of compromised anatomy or where the pattern of tooth loss is unfavourable, they provide a useful removable partial denture design option. The aim of this article is to provide a clear summary of the clinical and technical considerations necessary when providing a Swinglock denture.

  1. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    Science.gov (United States)

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from

  2. [Gerontoprosthesis. Concept of rebuilding old complete dentures].

    Science.gov (United States)

    Marxkors, R; Mayer, K

    1990-04-01

    If aged patients who have been wearing their full dentures without complications so far, need further prothetic treatment, the dentist must not replace the old denture by a completely new one. It is better to rebuild it step by step. This demand is based on the following theses: --Nobody but the patient himself is able to perform functional movements. --Unless bite and occlusion are correct, patients are not able to perform accurate functional movements. --When bite and occlusion have been checked and, if necessary, improved, bases and alveolar ridges must be congruent.

  3. Metallographic examination of EPICOR-II liners from Three Mile Island

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Spaletta, H.W.

    1985-01-01

    Materials from selected EPICOR-II prefilter liners were collected and examined as part of the EPICOR and Waste Research and Disposition Program sponsored by the Department of Energy at the Idaho National Engineering Laboratory (INEL). The intent of that examination was to define the internal condition of liners and ensure that liners could be stored at INEL for ten years. This paper discusses the liner-integrity examination and presents the results of these examinations. Metallurgical examination of sections removed from the liners revealed no evidence of pitting or pitting-type corrosion. Measurements of wall thickness indicate that material was missing from the wall of PF-3 in an area where the protective coating had been removed to form a conductivity patch. If it is assumed that all thinning of the wall in that area is caused by corrosion, the liners will have a lifetime of approximately 50 years. 12 figures

  4. The Oral Microbiome of Denture Wearers Is Influenced by Levels of Natural Dentition

    Science.gov (United States)

    O’Donnell, Lindsay E.; Robertson, Douglas; Nile, Christopher J.; Cross, Laura J.; Riggio, Marcello; Sherriff, Andrea; Bradshaw, David; Lambert, Margaret; Malcolm, Jennifer; Buijs, Mark J.; Zaura, Egija; Crielaard, Wim; Brandt, Bernd W.; Ramage, Gordon

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to understand the implications of these towards inter-kingdom and host-pathogen interactions within the oral cavity. Methods Swab samples were obtained from 123 participants wearing either a complete or partial denture; the bacterial composition of each sample was determined using bar-coded illumina MiSeq sequencing of the bacterial hypervariable V4 region of 16S rDNA. Sequencing data processing was undertaken using QIIME, clustered in Operational Taxonomic Units (OTUs) and assigned to taxonomy. The dentures were sonicated to remove the microbial flora residing on the prosthesis, sonicate was then cultured using diagnostic colorex Candida media. Samples of unstimulated saliva were obtained and antimicrobial peptides (AMP) levels were measured by ELISA. Results We have shown that dental and denture plaques are significantly distinct both in composition and diversity and that the oral microbiome composition of a denture wearer is variable and is influenced by the location within the mouth. Dentures and mucosa were predominantly made up of Bacilli and Actinobacteria. Moreover, the presence of natural teeth has a significant impact on the overall microbial composition, when compared to the fully edentulous. Furthermore, increasing levels of Candida spp. positively correlate with Lactobacillus spp. AMPs were quantified, though showed no specific correlations. Conclusions This is the first study to provide a detailed understanding of the oral microbiome of denture wearers and has provided evidence that DS development is more complex than simply a candidal infection. Both fungal and bacterial kingdoms clearly play a role in defining the progression of DS, though we were unable to

  5. Diminished Antimicrobial Peptide and Antifungal Antibiotic Activities against Candida albicans in Denture Adhesive

    Directory of Open Access Journals (Sweden)

    Amber M. Bates

    2017-02-01

    Full Text Available The underlying causes of denture stomatitis may be related to the long-term use of adhesives, which may predispose individuals to oral candidiasis. In this study, we hypothesize that antimicrobial peptides and antifungal antibiotics have diminished anti-Candida activities in denture adhesive. To show this, nine antimicrobial peptides and five antifungal antibiotics with and without 1.0% denture adhesive were incubated with Candida albicans strains ATCC 64124 and HMV4C in radial diffusion assays. In gels with 1.0% adhesive, HNP-1, HBD2, HBD3, IP-10, LL37 (only one strain, histatin 5 (only one strain, lactoferricin B, and SMAP28 showed diminished activity against C. albicans. In gels with 1.0% adhesive, amphotericin B and chlorhexidine dihydrochloride were active against both strains of C. albicans. These results suggest that denture adhesive may inactivate innate immune mediators in the oral cavity increasing the risk of C. albicans infections, but inclusion of antifungal antibiotics to denture adhesive may aid in prevention or treatment of Candida infections and denture stomatitis.

  6. The high pH chemical and radiation compatibility of various liner materials

    International Nuclear Information System (INIS)

    Whyatt, G.A.; Farnsworth, R.K.

    1990-01-01

    This paper reports on a flexible membrane liner that has been proposed to line a concrete vault in which liquid low-level radioactive waste will be solidified. High-density polyethylene (HDPE) and polypropylene liners were tested at the Pacific Northwest Laboratory in an EPA method 9090 format to determine their chemical compatibility with the waste. Radiation effects were also investigated. The liners were immersed in a highly caustic (pH>14), primarily inorganic solution at 90 degrees C. The liners were subjected to radiation doses up to 38.9 Mrad, which was the expected dose the liner would receive over a 30-year life inside the vault. Recent changes have placed the liner outside the vault. The acceptance criteria for judging the compatibility of the liner with radiation would be different that those used for judging chemical compatibility. The radiation damage over the life of the liner can be simulated in a short-term test. Both HDPE and polypropylene liners were judged to be acceptable from a chemical and radiation standpoint when placed outside of the vault, while several other liners were not compatible. Radiation did not have a significant effect on chemical degradation rates

  7. The high pH chemical and radiation compatibility of various liner materials

    International Nuclear Information System (INIS)

    Whyatt, G.; Farnsworth, R.

    1990-01-01

    A flexible membrane liner has been proposed to line a concrete vault in which liquid low-level radioactive waste will be solidified. High-density polyethylene (HDPE) and polypropylene liners were tested at the Pacific Northwest Laboratory in an EPA method 9090 format to determine their chemical compatibility with the waste. Radiation effects were also investigated. The liners were immersed in a highly caustic (pH>14), primarily inorganic solution at 90 degrees C. The liners were subjected to radiation doses up to 38.9 Mrad, which was the expected dose the liner would receive over a 30-year life inside the vault. Recent changes have placed the liner outside the vault. The acceptance criteria for judging the compatibility of the liner with radiation should be different than those used for judging chemical compatibility. The radiation damage over the life of the liner can be simulated in a short-term test. Both HDPE and polypropylene liners were judged to be acceptable from a chemical and radiation standpoint when placed outside of the vault, while several other liners were not compatible. Radiation did not have a significant effect on chemical degradation rates

  8. SECTIONAL MANDIBULAR COMPLETE DENTURE FOR A TOTAL MAXILLECTOMY PATIENT WITH TRISMUS: A CLINICAL REPORT

    Directory of Open Access Journals (Sweden)

    Tamer ÇELAKIL

    2017-10-01

    Full Text Available This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  9. Advantages of floating covers with LLDPE Liners

    International Nuclear Information System (INIS)

    Munoz Gomez, J. M.

    2014-01-01

    Using floating covers in irrigation pounds and waste dam gives many advantages. It is a very interesting investment for those place with a high evaporation ratio. this is an easy system which improves several aspects in irrigation or drinkable water reservoirs, mainly it saves water and it saves clean-works (time and cost). It is also used in waste dam to deodorization. Time ago this application was developed with PVC liners and TPO liners, now the innovation is LLDPE liners which improve mechanical properties, durability and an easier installation. This paper develops the state of art of this design technology, and the back ground of our experience. (Author)

  10. Inhibitory effects of Lactobacillus rhamnosus and Lactobacillus casei on Candida biofilm of denture surface.

    Science.gov (United States)

    Song, Young-Gyun; Lee, Sung-Hoon

    2017-04-01

    Candida albicans biofilm is associated with denture-related stomatitis and oral candidiasis of elderly. Probiotics are beneficial bacteria and have antibacterial activity against pathogenic bacteria. The purpose of this study was to investigate the antifungal activity of various probiotics against C. albicans and the inhibitory effects of probiotics on Candida biofilm on the denture surface. The spent culture media of various probiotics were investigated the antifungal efficacy against C. albicans. Candida biofilm was formed on a denture base resin and was then treated with Lactobacillus rhamnosus and Lactobacillus casei. Also, the biofilms of L. rhamnosus and L. casei were formed and were sequentially treated with C. albicans. Colony-forming units of C. albicans on the denture surface were counted after spreading on agar plate. The denture base resin was treated with the spent culture media for 30days, after which the denture surface roughness was analyzed with an atomic force microscope. L. rhamnosus and L. casei exhibited stronger antifungal activity than other probiotics. The spent culture medium of L. rhamnosus and L. casei exhibited the antifungal activity against blastoconidia and biofilm of C. albicans. L. rhamnosus and L. casei showed the antifungal activity against Candida biofilm, and the biofilm of L. rhamnosus and L. casei inhibited formation of Candida biofilm on denture surface. Neither of the probiotics affected the surface roughness of the denture base resin. L. rhamnosus and L. casei may be the ideal probiotics for the prevention and treatment of denture-related stomatitis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    Science.gov (United States)

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  12. Construction experience on PCRV liners at Fort St. Vrain

    International Nuclear Information System (INIS)

    Cliff, J.O.; Wunderlich, R.G.

    1976-01-01

    The construction of the steel liners for the Fort St. Vrain prestressed concrete reactor vessel presented many unique problems for which techniques were developed to satisfy the rigid specification requirements. The PCRV cavity liner was fabricated from 1.9cm carbon steel plate. The liners were partially fabricated by Pittsburgh-Des Moines Steel Company at their Pittsburgh manufacturing facility. The liners were then shipped by rail to within approximately five miles of the jobsite and then trucked the remaining distance. The construction techniques, dimensional control, concrete support and testing utilized on the Fort St. Vrain project are presented in detail and demonstrate the flexibility of the PCRV for field construction. (author)

  13. Repairing liner of the reactor; Reparacion del liner del reactor

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-07-15

    Due to the corrosion problems of the aluminum coating of the reactor pool, a periodic inspections program by ultrasound to evaluate the advance grade and the corrosion speed was settled down. This inspections have shown the necessity to repair some areas, in those that the slimming is significant, of not making it can arrive to the water escape of the reactor pool. The objective of the repair is to place patches of plates of 1/4 inch aluminum thickness in the areas of the reactor 'liner', in those that it has been detected by ultrasound a smaller thickness or similar to 3 mm. To carry out this the fuels are move (of the core and those that are decaying) to a temporary storage, the structure of the core is confined in a tank that this placed inside the pool of the reactor, a shield is placed in the thermal column and it is completely extracted the water for to leave uncover the 'liner' of the reactor. (Author)

  14. Accelerated aging tests of liners for uranium mill tailings disposal

    International Nuclear Information System (INIS)

    Barnes, S.M.; Buelt, J.L.; Hale, V.Q.

    1981-11-01

    This document describes the results of accelerated aging tests to determine the long-term effectiveness of selected impoundment liner materials in a uranium mill tailings environment. The study was sponsored by the US Department of Energy under the Uranium Mill Tailings Remedial Action Project. The study was designed to evaluate the need for, and the performance of, several candidate liners for isolating mill tailings leachate in conformance with proposed Environmental Protection Agency and Nuclear Regulatory Commission requirements. The liners were subjected to conditions known to accelerate the degradation mechanisms of the various liners. Also, a test environment was maintained that modeled the expected conditions at a mill tailings impoundment, including ground subsidence and the weight loading of tailings on the liners. A comparison of installation costs was also performed for the candidate liners. The laboratory testing and cost information prompted the selection of a catalytic airblown asphalt membrane and a sodium bentonite-amended soil for fiscal year 1981 field testing

  15. Collation of chewing efficiency and dentures with diverse occlusal schemes

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Peddinti

    2017-01-01

    Full Text Available Background: Rehabilitation of an edentulous patient nurtures satisfaction and this lies in the chewing ability provided by the prosthesis. Aim: To evaluate and compare the masticatory efficiencies of complete dentures with different occlusal schemes. Materials and Methods: Fourteen completely edentulous patients from the age group of 50-70 years were selected according to the inclusion criteria followed in this study. The dentures were made with three different occlusal schemes, i.e., anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion and stored in water till the date of denture insertion. Post-insertion instructions were given to the patients at the time of delivery of the dentures. Patients were recalled after seven days and then masticatory efficiency was performed. The test was performed using boiled peanuts and Sieve system. Statistical Analysis: One-way analysis of variance (ANOVA test and unpaired t-test were carried out. Results: The obtained masticatory efficiency values with anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion LO were analyzed using one-way ANOVA test and unpaired “t” test. The tests showed that lingualized scheme had highest masticatory efficiency. Conclusion: Within the scope of this study, it can be concluded that the masticatory efficiency will be generally higher in patients provided with complete dentures fabricated using the lingualized occlusal scheme.

  16. Waste Handling Shaft concrete liner degradation conclusions and recommendations

    International Nuclear Information System (INIS)

    1992-10-01

    The primary function of the Waste Handling Shaft (WHS) at the Waste Isolation Pilot Plant (WIPP) is to permit the transfer of radioactive waste from the surface waste handling building to the underground storage area. It also serves as an intake shaft for small volumes of air during normal storage operations and as an emergency escape route. Part of the construction was the placement of a concrete liner and steel reinforced key in 1984. During a routine shaft inspection in May 1990, some degradation of the WHS concrete liner was observed between the depths of 800 and 900 feet below the ground surface. Detailed investigations of the liner had been carried out by Sandia National Laboratories and by Westinghouse Electric Corporation Waste Isolation Division (WID) through Lankard Materials Laboratory. Observations, reports, and data support the conclusion that the concrete degradation, resulting from attack by chemically aggressive brine, is a localized phenomena. It is the opinion of the WID that the degradation is not considered an immediate or near term concern; this is supported by technical experts. WID recommendations have been made which, when implemented, will ensure an extended liner life. Based on the current assessment of available data and the proposed shaft liner monitoring program described in this report, it is reasonable to assume that the operational life of the concrete shaft liner can safely support the 25-year life of the WIPP. Analysis of data indicates that degradation of the shaft's concrete liner is attributed to chemically aggressive brine seeping through construction joints and shrinkage cracks from behind the liner in and around the 834-foot depth. Chemical and mechanical components of concrete degradation have been identified. Chemical attack is comprised of several stages of concrete alteration. The other component, mechanical degradation, results from the expansive forces of crystals forming in the concrete pore space

  17. Enhancing retention of partial dentures using elastomeric retention rings

    Directory of Open Access Journals (Sweden)

    Kakkirala Revathi

    2015-01-01

    Full Text Available This report presents an alternative method for the retention of partial dentures that relies on the engagement of tooth undercuts by a lining material. The lab procedures are also presented. A new maxillary and mandibular acrylic partial dentures were fabricated using elastomeric retention technique for a partially dentate patient. A partially dentate man reported difficulty in retaining his upper removable partial denture (RPD. The maxillary RPD was designed utilizing elastomeric retention technique. During follow-up, it was necessary to replace the retention rings due to wear. The replacement of the retention rings, in this case, was done through a chairside reline technique. Elastomeric retention technique provides exceptionally good retention can be indicated to stabilize, cushion, splint periodontally involved teeth, no enough undercut for clasps, eliminate extractions, single or isolated teeth.

  18. Connection of functional quality of partial removable dentures and the degree of patients' phonetic adaptation.

    Science.gov (United States)

    Artjomenko, Victoria; Vidzis, Aldis; Zigurs, Guntis

    2015-01-01

    Phonetic adaptation is a complex biological phenomenon with a highly individual course, depending on the patient's motivation to use prosthesis, on the functional quality of removable dentures. The aim of the study was to estimate phonetic adaptation in patients with partial dentures, connecting it to alteration in speech quality and dentures functional value. We examined some peculiarities of phonetic adaptation in 50 patients with removable dentures (50 patients with natural dentition were invited for the control group). The standardized evaluation protocols (12 speech quality determining parameters) were developed separately for Latvian and Russian native speakers. 500 speech video samples were recorded and analysed according to pre-established guidelines. The connection of speech quality and the functional quality of the dentures was assessed. Statistical analysis was performed using SPSS 20.0. P values equal to or less than 0.05 were considered to be statistically significant. In patients with appropriate functional quality of removable dentures distorted speech production was detected in 25% (pk=0.008) cases and in patients with inappropriate functional quality of the prosthesis - in 40% (pkdentures functional value were satisfied with their speech performance in 96% (pk=0.674), in the group with inappropriate dentures functional value only 59% (premovable dentures depends on the patient's individual adaptation capacity, prosthetic design and functional value. Thus statistically significant correlation between removable partial dentures functional value, duration of usage and the degree of patients' phonetic adaptation (p<0.001) may be considered to be confirmed.

  19. Removable Partial Denture Supported by Implants with Prefabricated Telescopic Abutments - A Case Report

    Science.gov (United States)

    Sehgal, Komal

    2014-01-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy—biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. PMID:25121066

  20. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    Science.gov (United States)

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  1. Etiological factors correlated with temporomandibular disorder in complete denture wearers: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Ricardo Alexandre Zavanelli

    2009-01-01

    Full Text Available Objective: The aim of this study was to make a comparative evaluation of the prevalence of temporomandibular disorder in complete denturewearers, with regard to the etiological factors, such as gender, age, and complete dentures clinical conditions, according to the anamnestic(Ai and clinical (Di dysfunction index, developed by Helkimo.Methods: The randomized sample was composed of 90 institutionalized patients and bimaxillary complete denture wearers, with a mean ageof 67.2 years, who were included in this study. The collected data were tabulated and the Kruskal-Wallis and Chi-square statistical tests were applied, at the level of significance of 5% (p<0.05.Results: Statistically significant difference in the prevalence of temporomandibular disorder was observed with regard to the ages of the current complete dentures, free-way space, wear of the occlusal surfaces of the artificial teeth, and the conditions of retention and stability of the maxillary and mandibular complete dentures, according to both the indexes. Conclusion: The patients who wore complete dentures in adequate clinical conditions presented fewer signs and symptoms of temporomandibular disorder than the patients who wore complete dentures in poor clinical conditions.

  2. Vinegar as an antimicrobial agent for control of Candida spp. in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Telma Maria Silva Pinto

    2008-12-01

    Full Text Available The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3 overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation. The results were analyzed using Spearman's correlation and Student's t-test (p£0.05. Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients.

  3. Construction and performance of a long-term earthen liner experiment

    Science.gov (United States)

    Cartwright, Keros; Krapac, Ivan G.; Bonaparte, Rudolph

    1990-01-01

    In land burial schemes, compacted soil barriers with low hydraulic conductivity are commonly used in cover and liner systems to control the movement of liquids and prevent groundwater contamination. An experimental liner measuring 8 x 15 x 0.9 m was constructed with design criteria and equipment to simulate construction of soil liners built at waste disposal facilities. The surface of the liner was flooded with a 29.5 cm deep pond on April 12, 1988. Infiltration of water into the liner has been monitored for two years using 4 large-ring (1.5 m OD) and 32 small-ring (0.28 m OD) infiltrometers, and a water-balance that accounts for total infiltration and evaporation. Average long-term infiltration fluxes based on two years of monitoring are 5.8 x 10-9 cm/s, 6.0 x 10-8 cm/s and 5.6 x 10-8 for the large-ring, small-ring, and water-balance data, respectively. The saturated hydraulic conductivity of the liner based on small-ring data, estimated using Darcy's Law and the Green-Ampt Approximation, is 3 x 10-8 and 4 x 10-8 cm/s, respectively. All sets of data indicate that the liner's performance exceed that which is required by the U.S. EPA.

  4. Symmetry of nonexploding cylindrical liner converging to the axis under magnetic field effects

    International Nuclear Information System (INIS)

    Chernyshev, V.K.; Grinevich, B.E.; Buzin, V.N.; Pogorelov, V.P.; Shertsov, V.A.; Petrukhin, A.A.; Demidov, V.A.; Zharinov, E.I.

    1990-01-01

    Liner acceleration, affected by magnetic pressure, is broadly used to yield megagauss magnetic fields and plasma compression. The progress of test conduction depends much on the state of liner subjected to Taylor instability while being accelerated. There is a number of methods permitting to reduce liner shape distortions, developing during its acceleration. The most simple method consists in that the aspect ratio (the ratio of liner placing radius to its thickness) is taken less than 10. To impart sufficient velocity to the liner of large thickness its density should be small. Therefore, liner is either a gas layer or explosion products of thin metal foil which passed to a vaporous state in early stage of acceleration. Acceleration of nonexploding liners may serve as the other method of asymmetry reduction. Strength and viscosity of liner will be used as stabilizing factors with respect to the development of Taylor instability. This will allow the aspect ratio increase, that is sometimes useful. Test results on acceleration of nonexploding aluminum liners 1 mm thick have been described. Aspect ratio amounted to 30-60 and the ratio of liner acceleration distance to its thickness (parameter, being of great importance when studying the development of Taylor instability) made up 20-40. Satisfactory azimuthal symmetry of liner convergence to the center was recorded. For more detailed investigation of Taylor instability influence on the symmetry of nonexploding liner, the experiments, when the ratio of liner acceleration length to its thickness would be increased up to 90-100 simultaneously with determination of azimuthal and axial symmetry of liner, are of interest. In this paper presents the results of experiments on acceleration of copper cylindrical liner 1.37 mm thick

  5. Conventional Complete Denture in Patients with Ectodermal Dysplasia

    Directory of Open Access Journals (Sweden)

    Larissa Soares Reis Vilanova

    2015-01-01

    Full Text Available Ectodermal dysplasia is described as heritable conditions that involve anomalies of structures derived from the ectoderm, including hypodontia. In the cases of edentulous young patients, who did not finish their craniofacial growth, treatment with conventional complete denture is a suitable alternative. The aim of this study was to report a case of mandibular edentulism treated with conventional complete denture in a thirteen-year-old patient diagnosed with hidrotic ectodermal dysplasia. Typical features, such as frontal bossing, depressed nasal bridge, protuberant lips, scarce hair, and brittle nails, were visualized during the extraoral examination. The intraoral inspection and radiographic analysis revealed oligodontia, dental malformation, and prolonged retention of deciduous teeth at maxilla and total edentulism at mandible. A conventional complete denture was planned and constructed following the same steps of technique as recommended in adults. Although this option is not a definitive treatment, the patient and his parents were satisfied with his improvement in chewing and speech, as well as with the aesthetic benefits.

  6. Cytotoxicity of four denture adhesives on human gingival fibroblast cells.

    Science.gov (United States)

    Lee, Yoon; Ahn, Jin-Soo; Yi, Young-Ah; Chung, Shin-Hye; Yoo, Yeon-Jee; Ju, Sung-Won; Hwang, Ji-Yun; Seo, Deog-Gyu

    2015-02-01

    The purpose of this study was to compare the cytotoxicity of four denture adhesives on human gingival fibroblast cells. Immortalized human gingival fibroblasts were cultured with one of four different denture adhesives, Polident, Protefix, Staydent or Denfix-A, which was placed in insert dishes (10% w/v concentration) for 48 h. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and flow cytometric apoptosis assay were used to evaluate cell viability and apoptosis rates. The fibroblasts were also examined under a scanning electron microscope. The MTT assay showed that all denture adhesives resulted in a significantly lower cell viability compared to the control cells propagated in normal culture medium (p 0.05). Staydent showed the highest apoptosis rate. Scanning electron microscopy showed that the cells of the Staydent group underwent cytoplasmic membrane shrinkage, with cell free areas containing residual fragments of the membrane of dead cells. The four denture adhesives evaluated in this study imparted cytotoxic effects on human gingival fibroblast cells. Staydent showed the highest toxicity.

  7. Patient's Satisfaction with Removable Partial Dentures: A Retrospective Case Series.

    Science.gov (United States)

    Shala, Kujtim Sh; Dula, Linda J; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient's satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient's satisfaction with RPD with or without attachment. Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.

  8. Effect of biofilm formation, and biocorrosion on denture base fractures.

    Science.gov (United States)

    Sahin, Cem; Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-05-01

    The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P.05). All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.

  9. Denture identification using unique identification authority of India barcode

    OpenAIRE

    Sudhindra Mahoorkar; Anoop Jain

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  10. Denture identification using unique identification authority of India barcode.

    Science.gov (United States)

    Mahoorkar, Sudhindra; Jain, Anoop

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  11. Optimization of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction

    Science.gov (United States)

    Jones, M. G.; Watson, W. R.; Nark, D. M.; Schiller, N. H.; Born, J. C.

    2016-01-01

    This paper employs three acoustic propagation codes to explore variable-depth liner configurations for the NASA Langley Grazing Flow Impedance Tube (GFIT). The initial study demonstrates that a variable impedance can acceptably be treated as a uniform impedance if the spatial extent over which this variable impedance occurs is less than one-third of a wavelength of the incident sound. A constrained optimization study is used to design a variable-depth liner and to select an optimization metric. It also provides insight regarding how much attenuation can be achieved with variable-depth liners. Another optimization study is used to design a liner with much finer chamber depth resolution for the Mach 0.0 and 0.3 test conditions. Two liners are designed based on spatial rearrangement of chambers from this liner to determine whether the order is critical. Propagation code predictions suggest this is not the case. Both liners are fabricated via additive manufacturing and tested in the GFIT for the Mach 0.0 condition. Predicted and measured attenuations compare favorably across the full frequency range. These results clearly suggest that the chambers can be arranged in any order, thus offering the potential for innovative liner designs to minimize depth and weight.

  12. Modeling of Broadband Liners Applied to the Advanced Noise Control Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.; Sutliff, Daniel L.

    2015-01-01

    The broadband component of fan noise has grown in relevance with an increase in bypass ratio and incorporation of advanced fan designs. Therefore, while the attenuation of fan tones remains a major factor in engine nacelle acoustic liner design, the simultaneous reduction of broadband fan noise levels has received increased interest. As such, a previous investigation focused on improvements to an established broadband acoustic liner optimization process using the Advanced Noise Control Fan (ANCF) rig as a demonstrator. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom liner designs were carried through design, fabrication, and testing. This paper addresses a number of areas for further research identified in the initial assessment of the ANCF study. Specifically, incident source specification and uncertainty in some aspects of the predicted liner impedances are addressed. This information is incorporated in updated predictions of the liner performance and comparisons with measurement are greatly improved. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of various liner designs. This study also provides further confidence in the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

  13. Telescopic Partial Dentures-Concealed Technology.

    Science.gov (United States)

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-09-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of "floating plastic" in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental implants or fixed partial denture is the better options, but they have certain limitations. However, overdentures and particularly telescopic denture is the overlooked technology in dentistry that would be a boon for such needy patients. Telescopic denture is especially indicated in the distal edentulous area with minimum two teeth bilaterally present with a good amount of periodontal support. This treatment modality is sort of preventive prosthodontics remedy, which in a conservative manner preserve the remaining teeth and helps in conservation of alveolar bone ultimately. There are two tenets related to this option, one is constant conservation edentulous ridge around the retained tooth and the most important is the endless existence of periodontal sensory action that directs and monitor gnathodynamic task. In this option the primary coping or inner coping are cemented on the prepared tooth, and a similar removable outer or inner telescopic crown placed tightly by using a mechanism of tenso-friction, this is firmly attached to a removable RPD in place without moving or rocking of the prosthesis, which is the common compliant of almost all patients of RPD. Copings are also protecting the abutment from tooth decay and also offers stabilization and maintaining of the outer crown. The outer crown engages the inner coping and gives as an anchor for the remainder of the dentition. This work is the review of telescopic prosthesis which is well supported by the case discussion, and

  14. Correlation between factors associated with the removable partial dentures use and Candida spp. in saliva.

    Science.gov (United States)

    Gusmão, João Milton Rocha; Ferreira dos Santos, Silvana Soleo; Neisser, Maximiliano Piero; Jorge, Antônio Olavo Cardoso; Faria, Ms Ivan

    2011-12-01

    To correlate the presence and number of Candida spp. in the saliva of wearers of removable partial dentures retained with precision attachments with the proportion of metal/acrylic resin present in the dentures. Saliva samples from 40 removable partial denture wearers (test) and one paired sample of individuals, non-wearers of any type of removable denture (control) were collected, seeded, and the colony forming units of Candida counted and identified. The metal/acrylic resin proportion of each denture was quantified, using silicone plates pressed over each denture. Candida spp. was found in the saliva of 80% of the individuals in the test group and 65% of the control, with C. albicans being the most prevalent species. The test group presented with the highest number of colony forming units of Candida per ml of saliva, and there was weak correlation between this number and the metal and resin area of the denture (Pearson's coefficient of correlation). Greater prevalence and a higher number of colony forming units of Candida per ml of saliva occurred in removable partial denture wearers (p = 0.04) with a weak positive correlation between the metal and resin area and the number of colony forming units of Candida per ml of saliva. However, this correlation was more significant for the area of resin. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  15. Use of Candida-specific chicken egg yolk antibodies to inhibit the adhering of Candida to denture base materials: prevention of denture stomatitis.

    Science.gov (United States)

    Kamikawa, Yoshiaki; Fujisaki, Junichi; Nagayama, Tomohiro; Kawasaki, Kiyotsugu; Hirabayashi, Daisuke; Hamada, Tomofumi; Sakamoto, Ryoich; Mukai, Hiroshi; Sugihara, Kazumasa

    2016-09-01

    Polyclonal anti-Candida chicken egg yolk antibodies (anti-IgY) were used to investigate the prevention of adherence of Candida species to denture base material in vitro. Candida is a potential virulence factor that can cause systemic infection and even death in immunocompromised individuals. Because long-term antifungal treatment may lead to the emergence of drug-resistant strains, it is necessary to develop novel preventive measures and treatments for candidiasis. Three types of chicken egg yolk antibodies were used in this study: non-specific antibody (control IgY), Candida albicans-specific antibody (anti-C.a.IgY) and Candida glabrata-specific antibody (anti-C.g.IgY). A mixture of different dilutions of each antibody with a suspension of Candida species and denture base material was incubated for 3 h, and then the colony-forming units of Candida on the denture base material were counted. Compared with control IgY, anti-C.a.IgY and anti-C.g.IgY significantly inhibited the adherence of C. albicans, but anti-C.a.IgY tended to be more potent than anti-C.g.IgY. The adherence of C. glabrata was also inhibited significantly by anti-C.a.IgY and anti-C.g.IgY with almost equivalent potency, indicating that their actions against C. glabrata were comparable. This study revealed the inhibitory effects of anti-C.a.IgY and anti-C.g.IgY against the adherence of C. albicans and C. glabrata to denture base material. This finding indicates the possibility of a beneficial effect of IgYs for the prevention of denture stomatitis and candidiasis in clinical settings. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  16. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study

    Directory of Open Access Journals (Sweden)

    Abhishek Shekhar

    2018-01-01

    Conclusions: Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  17. Evaluation of articulation of Turkish phonemes after removable partial denture application

    Directory of Open Access Journals (Sweden)

    Özbeki Murat

    2003-01-01

    Full Text Available In this study, the adaptation of patients to removable partial dentures was evaluated related to articulation of Turkish phonemes. Articulation of /t,d,n,l,r/, /g,k/, /b,p,m/ and /s,z,Õ,v,f,y,j,h,c/ phonemes were evaluated by three speech pathologists, on records taken from 15 patients before the insertion of a removable partial denture, just after insertion, and one week later. The test consisted of evaluation of phoneme articulation of independent syllables in terms of distortion, omission, substitution, mass effect, hypernasality and hyponasality. Data were evaluated with Cochrane Q, McNemar and Kruskal-Wallis tests. The results showed that for some phonemes, problems in articulation occurred after the insertion of a removable partial denture while for others a significant amelioration was observed after the insertion of a removable partial denture. In general, problems in articulation of evaluated phonemes were resolved after one week of use.

  18. Migration behavior of landfill leachate contaminants through alternative composite liners

    Energy Technology Data Exchange (ETDEWEB)

    Varank, Gamze, E-mail: gvarank@yildiz.edu.tr; Demir, Ahmet, E-mail: ahmetd@yildiz.edu.tr; Top, Selin, E-mail: stop@yildiz.edu.tr; Sekman, Elif, E-mail: esekman@yildiz.edu.tr; Akkaya, Ebru, E-mail: ekoca@yildiz.edu.tr; Yetilmezsoy, Kaan, E-mail: yetilmez@yildiz.edu.tr; Bilgili, M. Sinan, E-mail: mbilgili@yildiz.edu.tr

    2011-08-01

    Four identical pilot-scale landfill reactors with different alternative composite liners were simultaneously operated for a period of about 540 days to investigate and to simulate the migration behaviors of phenolic compounds (phenol, 2-CP, 2-MP, 3-MP, 4-MP, 2-NP, 4-NP, 2,4-DNP, 2,4-DCP, 2,6-DCP, 2,4,5-TCP, 2,4,6-TCP, 2,3,4,6-TeCP, PCP) and heavy metals (Pb, Cu, Zn, Cr, Cd, Ni) from landfill leachate to the groundwater. Alternative landfill liners of four reactors consist of R1: Compacted clay liner (10 cm + 10 cm, k = 10{sup -8} m/sn), R2: Geomembrane (2 mm HDPE) + compacted clay liner (10 cm + 10 cm, k = 10{sup -8} m/sn), R3: Geomembrane (2 mm HDPE) + compacted clay liner (10 cm, k = 10{sup -8} m/sn) + bentonite liner (2 cm) + compacted clay liner (10 cm, k = 10{sup -8} m/sn), and R4: Geomembrane (2 mm HDPE) + compacted clay liner (10 cm, k = 10{sup -8} m/sn) + zeolite liner (2 cm) + compacted clay liner (10 cm, k = 10{sup -8} m/sn). Wastes representing Istanbul municipal solid wastes were disposed in the reactors. To represent bioreactor landfills, reactors were operated by leachate recirculation. To monitor and control anaerobic degradation in the reactors, variations of conventional parameters (pH, alkalinity, chloride, conductivity, COD, TOC, TKN, ammonia and alcaly metals) were also investigated in landfill leachate samples. The results of this study showed that about 35-50% of migration of organic contaminants (phenolic compounds) and 55-100% of migration of inorganic contaminants (heavy metals) to the model groundwater could be effectively reduced with the use of bentonite and zeolite materials in landfill liner systems. Although leachate contaminants can reach to the groundwater in trace concentrations, findings of this study concluded that the release of these compounds from landfill leachate to the groundwater may potentially be of an important environmental concern based on the experimental findings. - Research highlights: {yields} Migration of

  19. Repairing liner of the reactor; Reparacion del liner del reactor

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-07-15

    Due to the corrosion problems of the aluminum coating of the reactor pool, a periodic inspections program by ultrasound to evaluate the advance grade and the corrosion speed was settled down. This inspections have shown the necessity to repair some areas, in those that the slimming is significant, of not making it can arrive to the water escape of the reactor pool. The objective of the repair is to place patches of plates of 1/4 inch aluminum thickness in the areas of the reactor 'liner', in those that it has been detected by ultrasound a smaller thickness or similar to 3 mm. To carry out this the fuels are move (of the core and those that are decaying) to a temporary storage, the structure of the core is confined in a tank that this placed inside the pool of the reactor, a shield is placed in the thermal column and it is completely extracted the water for to leave uncover the 'liner' of the reactor. (Author)

  20. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    Science.gov (United States)

    Allen, Finbarr

    2010-01-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  1. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2011-03-15

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  2. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2010-10-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  3. USSR imploding liner program

    International Nuclear Information System (INIS)

    Shearer, J.W.

    1975-01-01

    A summary is given of the history and rationale of the USSR program to implode metallic liners for the fusion program. The explosive driven, magnetic drive, and compressed gas driven research is reviewed. (MOW)

  4. One-and-Two-Dimensional Simulations of Liner Performance at Atlas Parameters

    International Nuclear Information System (INIS)

    Keinigs, R.K.; Atchison, W.L.; Faehl, R.J.; Mclenithan, K.D.; Trainor, R.J.

    1998-01-01

    The authors report results of one-and-two-dimensional MHD simulations of an imploding heavy liner in Z-pinch geometry. The driving current has a pulse shape and peak current characteristic of the Atlas pulsed-power facility being constructed at Los Alamos National Laboratory. One-dimensional simulations of heavy composite liners driven by 30 MA currents can achieve velocities on the order of 14 km/sec. Used to impact a tungsten target, the liner produces shock pressures of ∼ fourteen megabars. The first 2-D simulations of imploding liners driven at Atlas current parameters are also described. These simulations have focused on the interaction of the liner with the glide planes, and the effect of realistic surface perturbations on the dynamics of the pinch. It is found that the former interaction does not seriously affect the inner liner surface. Results from the second problem indicate that a surface perturbation having amplitude as small as 0.2 microm can have a significant effect on the implosion dynamics

  5. Metallurgical examination of, and resin transfer from, Three Mile Island prefilter liners

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Jr, J W; Spaletta, H W

    1984-08-01

    Metallurgical examinations were performed on two EPICOR-II prefilter liners at the Idaho National Engineering Laboratory (INEL) to determine conditions of the liners and identify the minimum expected lifetime of those and other liners stored at INEL. The research work was accomplished by EG and G Idaho, Inc. for the EPICOR-II Research and Disposition Program, which is funded by the US Department of Energy. The EPICOR-II prefilter liners were used to filter radionuclides from contaminated water during cleanup of Three Mile Island Unit 2 (TMI-2). The liners were constructed of carbon steel with a phenolic protective coating and contained organic and inorganic ion-exchange filtration media. Program plans call for interim storage of EPICOR-II prefilters at INEL for up to ten years, before final disposal in high integrity containers at the Hanford, Washington commercial disposal site. This report describes the (a) resin transfer process used to empty liners for examination, (b) removal of metallographic sections from those liners, (c) specimen preparation, and (d) findings from metallographic examination of those specimens. A minimum lifetime for the liners is determined and recommendations are given for storage of wastes from future TMI-2 activities.

  6. Metallurgical examination of, and resin transfer from, Three Mile Island prefilter liners

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Spaletta, H.W.

    1984-08-01

    Metallurgical examinations were performed on two EPICOR-II prefilter liners at the Idaho National Engineering Laboratory (INEL) to determine conditions of the liners and identify the minimum expected lifetime of those and other liners stored at INEL. The research work was accomplished by EG and G Idaho, Inc. for the EPICOR-II Research and Disposition Program, which is funded by the US Department of Energy. The EPICOR-II prefilter liners were used to filter radionuclides from contaminated water during cleanup of Three Mile Island Unit 2 (TMI-2). The liners were constructed of carbon steel with a phenolic protective coating and contained organic and inorganic ion-exchange filtration media. Program plans call for interim storage of EPICOR-II prefilters at INEL for up to ten years, before final disposal in high integrity containers at the Hanford, Washington commercial disposal site. This report describes the (a) resin transfer process used to empty liners for examination, (b) removal of metallographic sections from those liners, (c) specimen preparation, and (d) findings from metallographic examination of those specimens. A minimum lifetime for the liners is determined and recommendations are given for storage of wastes from future TMI-2 activities

  7. Composite-Material Tanks with Chemically Resistant Liners

    Science.gov (United States)

    DeLay, Thomas K.

    2004-01-01

    Lightweight composite-material tanks with chemically resistant liners have been developed for storage of chemically reactive and/or unstable fluids . especially hydrogen peroxide. These tanks are similar, in some respects, to the ones described in gLightweight Composite-Material Tanks for Cryogenic Liquids h (MFS-31379), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 58; however, the present tanks are fabricated by a different procedure and they do not incorporate insulation that would be needed to prevent boil-off of cryogenic fluids. The manufacture of a tank of this type begins with the fabrication of a reusable multisegmented aluminum mandrel in the shape and size of the desired interior volume. One or more segments of the mandrel can be aluminum bosses that will be incorporated into the tank as end fittings. The mandrel is coated with a mold-release material. The mandrel is then heated to a temperature of about 400 F (approximately equal to 200 C) and coated with a thermoplastic liner material to the desired thickness [typically approxiamtely equal to 15 mils (approximately equal to 0.38 mm)] by thermal spraying. In the thermal-spraying process, the liner material in powder form is sprayed and heated to the melting temperature by a propane torch and the molten particles land on the mandrel. The sprayed liner and mandrel are allowed to cool, then the outer surface of the liner is chemically and/or mechanically etched to enhance bonding of a composite overwrap. The etched liner is wrapped with multiple layers of an epoxy resin reinforced with graphite fibers; the wrapping can be done either by manual application of epoxy-impregnated graphite cloth or by winding of epoxy-impregnated filaments. The entire assembly is heated in an autoclave to cure the epoxy. After the curing process, the multisegmented mandrel is disassembled and removed from inside, leaving the finished tank. If the tank is to be used for storing hydrogen peroxide, then the liner material

  8. Advanced Computational and Experimental Techniques for Nacelle Liner Performance Evaluation

    Science.gov (United States)

    Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.; Nark, Douglas

    2009-01-01

    The Curved Duct Test Rig (CDTR) has been developed to investigate sound propagation through a duct of size comparable to the aft bypass duct of typical aircraft engines. The axial dimension of the bypass duct is often curved and this geometric characteristic is captured in the CDTR. The semiannular bypass duct is simulated by a rectangular test section in which the height corresponds to the circumferential dimension and the width corresponds to the radial dimension. The liner samples are perforate over honeycomb core and are installed on the side walls of the test section. The top and bottom surfaces of the test section are acoustically rigid to simulate a hard wall bifurcation or pylon. A unique feature of the CDTR is the control system that generates sound incident on the liner test section in specific modes. Uniform air flow, at ambient temperature and flow speed Mach 0.275, is introduced through the duct. Experiments to investigate configuration effects such as curvature along the flow path on the acoustic performance of a sample liner are performed in the CDTR and reported in this paper. Combinations of treated and acoustically rigid side walls are investigated. The scattering of modes of the incident wave, both by the curvature and by the asymmetry of wall treatment, is demonstrated in the experimental results. The effect that mode scattering has on total acoustic effectiveness of the liner treatment is also shown. Comparisons of measured liner attenuation with numerical results predicted by an analytic model based on the parabolic approximation to the convected Helmholtz equation are reported. The spectra of attenuation produced by the analytic model are similar to experimental results for both walls treated, straight and curved flow path, with plane wave and higher order modes incident. The numerical model is used to define the optimized resistance and reactance of a liner that significantly improves liner attenuation in the frequency range 1900-2400 Hz. A

  9. Photodynamic antimicrobial therapy in the treatment of denture stomatitis

    International Nuclear Information System (INIS)

    Senna, Andre Machado de

    2012-01-01

    Denture stomatitis (DS), also called chronic atrophic candidiasis, is the most common oral fungal infection in denture wearers. It has a multifactorial etiology, but the presence of Candida spp. biofilm on the denture is considered the most important factor for the establishment of the DS. This study aimed to evaluate the treatment of DS through the use of photodynamic antimicrobial therapy (PAT), mediated by methylene blue. For this purpose, preclinical studies and clinical trials were performed. Simulators prototypes dentures were made of methyl methacrylate polymer to serve as a basis for biofilm growth of the following species of Candida: C. albicans, C. glabrata, C. dubliniensis, C. krusei, C. tropicalis, C. parapsilosis and C. guilliermondii. Methylene blue solution at a concentration of 450 μg/mL was used as a photosensitizer. The prototypes and biofilms were irradiated with a laser of wavelength of 660 nm, potency of 100 mW, for 80 seconds. For the clinical study, subjects were divided into two groups. The first group received conventional treatment based on the use of antifungal Miconazole. The second group received the treatment by PAT. The preclinical results showed that all species of the genus Candida were susceptible to PAT, with a reduction in colonies that ranged from 2.48 to 3.93 log 10 . Clinical outcomes were evaluated for the reduction of colonies of Candida spp. located in the mucosa and in the prosthesis and relative to the improvement of the clinical aspect of the affected mucosa. Both the conventional therapy and PAT were effective in treating DS. There was no significant statistical difference between PAT and conventional treatment for any of the factors evaluated. Thus, it was concluded that PAT is effective in the treatment of denture stomatitis. (author)

  10. A comparative study for plaque removing efficacy between commonly used denture cleansers in India

    Directory of Open Access Journals (Sweden)

    Bhushan Kumar

    2017-01-01

    Conclusions: There was no significant difference among action of four denture cleansers used in this study. Thus we can infer that patients can use liquid handwashing soap or commercial products to overcome disadvantages of toothpastes. Recommendation from the results of this study is the use of liquid handwashing soap for cleansing after every meal and soaking of the denture in commercial denture cleanser during the night.

  11. Generation of rotation and shear flow in an imploding liner

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, J H; Ryutov, D D [Lawrence Livermore National Lab., Livermore, CA (United States)

    1997-12-31

    There exist several techniques that can set the liner into rotation and/or excite an embedded shear flow at any desired depth of the liner material. A common element of all these techniques is the use of properly used left-right asymmetric structures, situated either on the liner surface or embedded in the shell. Both rotation and shear flow get enhanced in the course of the liner implosion because of the angular momentum conservation. While fast enough rotation should stabilize the Rayleigh-Taylor instability near the turn-around point, the shear flow can also have a stabilizing effect on the interface. The specific model presented in the paper shows that a strong enough shear causes stabilization of a broad class of Rayleigh-Taylor perturbations. Thus, the use of left-right asymmetric structure for generation of rotation and shear flow is an interesting new option for improvement of the quality of the liner implosions. (J.U.). 4 figs., 12 refs.

  12. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  13. Above-cutoff impedance measurements of pumping holes for the Collider Liner

    International Nuclear Information System (INIS)

    Walling, L.; Barts, T.; Ruiz, E.; Turner, W.; Spayd, N.

    1994-04-01

    A holed liner was considered for the Superconducting Super Collider (SSC) Collider Ring because of vacuum problems caused by photon-induced desorption. The liner would serve to shield the cold surface of the beam tube from the synchrotron radiation and the holes (or slots) would allow distributed pumping by gas-absorption material that could be placed between the liner and the beam tube. The impedance of holes and slots in a liner were studied by means of simulations using both MAFIA and HFSS, analytical modelling, wire measurements and electron beam measurements

  14. Experimental Evaluation of Acoustic Engine Liner Models Developed with COMSOL Multiphysics

    Science.gov (United States)

    Schiller, Noah H.; Jones, Michael G.; Bertolucci, Brandon

    2017-01-01

    Accurate modeling tools are needed to design new engine liners capable of reducing aircraft noise. The purpose of this study is to determine if a commercially-available finite element package, COMSOL Multiphysics, can be used to accurately model a range of different acoustic engine liner designs, and in the process, collect and document a benchmark dataset that can be used in both current and future code evaluation activities. To achieve these goals, a variety of liner samples, ranging from conventional perforate-over-honeycomb to extended-reaction designs, were installed in one wall of the grazing flow impedance tube at the NASA Langley Research Center. The liners were exposed to high sound pressure levels and grazing flow, and the effect of the liner on the sound field in the flow duct was measured. These measurements were then compared with predictions. While this report only includes comparisons for a subset of the configurations, the full database of all measurements and predictions is available in electronic format upon request. The results demonstrate that both conventional perforate-over-honeycomb and extended-reaction liners can be accurately modeled using COMSOL. Therefore, this modeling tool can be used with confidence to supplement the current suite of acoustic propagation codes, and ultimately develop new acoustic engine liners designed to reduce aircraft noise.

  15. Time constrained liner shipping network design

    DEFF Research Database (Denmark)

    Karsten, Christian Vad; Brouer, Berit Dangaard; Desaulniers, Guy

    2017-01-01

    We present a mathematical model and a solution method for the liner shipping network design problem. The model takes into account coordination between vessels and transit time restrictions on the cargo flow. The solution method is an improvement heuristic, where an integer program is solved...... iteratively to perform moves in a large neighborhood search. Our improvement heuristic is applicable as a real-time decision support tool for a liner shipping company. It can be used to find improvements to the network when evaluating changes in operating conditions or testing different scenarios...

  16. Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2015-01-01

    Full Text Available Background: The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. Methods: Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC, lateral incisor (IL, canine (Ca, first premolar (P1, second premolar (P2, first molar (M1, and second molar (M2 regions. The thickness was measured in the alveolar ridge crest (T, buccal (B1-B4, and lingual (L1-L4 alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B and lingual sides (L were also assessed. Results: The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01. On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01, and was thicker than IC, IL, P1, and P2 at B2. Conclusions: Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.

  17. Detection of improvement in the masticatory function from old to new removable partial dentures using mixing ability test.

    Science.gov (United States)

    Asakawa, A; Fueki, K; Ohyama, T

    2005-09-01

    The aim of this study was to determine the sensitivity of the Mixing Ability Test to detect improvement of masticatory function in subjects on transition from old to new removable partial dentures. Thirty-two subjects (seven males, 25 females, mean age 65.0 years) with distal extension partially edentulous area in mandible and/or maxilla participated in the study. The following reasons were presented for replacing the old removable partial dentures with new ones: fracture and/or poor fitness of retainers, extraction of abutment teeth, poor fitness of denture base, severe wear of artificial teeth and request for metal base dentures. Masticatory function with old and new removable partial dentures after an adaptation period (mean 27.4 weeks) was evaluated by the Mixing Ability Test. Subjects were asked to masticate five two-coloured wax cubes with each removable partial denture. Mixing Ability Index was obtained from the colour mixture and shape of the masticated cubes. Wilcoxon signed-rank test was used to test the difference of Mixing Ability Indexes between old and new removable partial dentures. The mixing ability indexes with new removable partial dentures (mean+/- s.d.: 0.70+/- 0.68) was significantly higher (Premovable partial dentures (-0.11+/-1.13). The results suggest that the Mixing Ability Test was capable of detecting improvement in masticatory function with new removable partial dentures.

  18. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Science.gov (United States)

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  19. Survivorship of Total Hip Joint Replacements Following Isolated Liner Exchange for Wear.

    Science.gov (United States)

    Vadei, Leone; Kieser, David C; Frampton, Chris; Hooper, Gary

    2017-11-01

    Liner exchange for articular component wear in total hip joint replacements (THJRs) is a common procedure, often thought to be benign with reliable outcomes. Recent studies, however, suggest high failure rates of liner exchange revisions with significant complications. The primary aim of this study was, therefore, to analyze the survivorship of isolated liner exchange for articular component wear, and secondarily to assess the influence of patient demographics (gender, age, and American Society of Anaesthesiologists [ASA] ratings) on rerevisions following isolated liner exchange for wear. A retrospective review of the 15-year New Zealand Joint Registry (1999-2014) was performed, analyzing the outcomes of isolated liner exchange for articular component wear. The survivorship as defined as rerevision with component exchange was determined and 10-year Kaplan-Meier survivorship curves were constructed. These revision rates were compared to age, gender, and ASA rating groups using a log-rank test. The 10-year survivorship of THJR following liner exchange revision for liner wear was 75.3%. If a rerevision was required, the median time to rerevision was 1.33 years with a rerevision rate of 3.33 per 100 component years (95% confidence interval 2.68-4.08/100 component years). The principle reasons for rerevision were dislocation (48.4%) and acetabular component loosening (20.9%). There was no statistically significant difference in rerevision rates based on gender, age categories, or ASA scores. THJR isolated liner exchange for liner wear is not a benign procedure with a survivorship of 75.3% at 10 years. Surgeons contemplating liner exchange revisions should be cognisant of this risk and should adequately assess component position and stability preoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Usage of removable partial dentures in Saudi male patients after 1 year telephone interview

    Science.gov (United States)

    Akeel, Riyadh

    2010-01-01

    Objective The success of removable partial dentures (RPDs) is partly dependent on patients’ acceptance and compliance in using them. The purpose of this study was to describe the usage of removable partial dentures (RPDs) by patients 1 year after insertion and to evaluate the factors that influence their denture usage. Methods Forty-seven patients who received 75 new RPDs at the undergraduate clinic of College of Dentistry, King Saud University, were contacted by telephone 1 year later for an interview. The questions covered denture usage, patient’s satisfaction and reasons for non-use. Results Results showed that 36% of patients discarded or occasionally used their RPDs. There was no significant association between denture usage and RPD experience, location or Kennedy classification. A significantly more RPD rejection was found when it was opposed by natural teeth or complete denture. The most quoted reason for RPD rejection was pain and discomfort. Conclusion Despite the short follow-up period, RPDs were poorly accepted by patients treated by undergraduate students. PMID:23960487

  1. Patient’s Satisfaction with Removable Partial Dentures: A Retrospective Case Series

    Science.gov (United States)

    Shala, Kujtim Sh.; Dula, Linda J.; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient’s satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. Material and Methods: A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. Result: The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient’s satisfaction with RPD with or without attachment. Conclusion: Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics. PMID:28077970

  2. Liner system design

    International Nuclear Information System (INIS)

    Hutchinson, I.P.G.; Ellison, R.D.

    1992-01-01

    This paper discusses one of the most important regulatory and design decisions which is determining the type of liner system. The liner system includes a combination of low hydraulic conductivity and leakage control materials to be provided beneath a mine waste management unit to avoid seepage losses, which could result in an unacceptable threat to beneficial uses of ground water. This is more difficult for mine wastes than for other types of waste disposal because: The physical and chemical properties of mine wastes vary widely; The sizes )volume and areal extent) of mine waste management units is often very large so that the costs of liners can impact economic feasibility of some operations. The U.S. Congress considered the differences between mine wastes and other types of wastes when it passed the Bevill amendment to the Resource Conservation and Recovery Act (RCRA) in 1980. That amendment exempted most mine wastes from hazardous waste regulation until the United States Environmental Protection Agency (EPA) conducted a study to determine the appropriate degree of regulation for mine wastes. In 1986, the EPA issued a report recognizing that, with a few exceptions for certain processed materials, mine wastes do not present the same level of threat as other wastes and therefore should be regulated differently. An additional important factor which differentiates mine waste disposal management units form other solid waste disposal units is that, except in unusual circumstances, mine and process facilities are located where the mineral resource is being extracted. Therefore, the location of the mine waste disposal facilities cannot solely be based upon a site selection study. as a result, some mines are located where the distance or depth to a valuable water resource is relatively small, while others are located in remote desert areas with no contiguous surface water resources, and deep ground water of limited quantity and/or quality

  3. Imploding-liner reactor nucleonic studies: the LINUS blanket

    International Nuclear Information System (INIS)

    Dudziak, D.J.

    1977-09-01

    Scoping nucleonic studies have been performed for a small imploding-liner fusion reactor concept. Tritium breeding ratio and time-dependent energy deposition rates were the primary parameters of interest in the study. Alloys of Pb and LiPb were considered for the liquid liner (blanket), and tritium breeding was found to be more than adequate with blankets less than 1 m thick. However, neutron leakages into the solid cylinder block surrounding the liquid liner are generally quite high, so considerable effort was concentrated on minimizing these values. Time-dependent calculations reveal that 89% of the energy is deposited in the blanket within 2 μs. Thus, LINUS's blanket should remain intact for the requisite neutron and gamma-ray lifetimes

  4. Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study.

    Science.gov (United States)

    Dula, Linda J; Ahmedi, Enis F; Lila-Krasniqi, Zana D; Shala, Kujtim Sh

    2015-01-01

    The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at pdenture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD's, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp pdentures and below the clasp arms in abutment teeth.

  5. Prefabricated light-polymerizing plastic pattern for partial denture framework

    Directory of Open Access Journals (Sweden)

    Atsushi Takaichi

    2011-01-01

    Full Text Available Our aim is to report an application of a prefabricated light-polymerizing plastic pattern to construction of removable partial denture framework without the use of a refractory cast. A plastic pattern for the lingual bar was adapted on the master cast of a mandibular Kennedy class I partially edentulous patient. The pattern was polymerized in a light chamber. Cobalt-chromium wires were employed to minimize the potential distortion of the plastic framework. The framework was carefully removed from the master cast and invested with phosphate-bonded investment for the subsequent casting procedures. A retentive clasp was constructed using 19-gauge wrought wire and was welded to the framework by means of laser welding machine. An excellent fit of the framework in the patient′s mouth was observed in the try-in and the insertion of the denture. The result suggests that this method minimizes laboratory cost and time for partial denture construction.

  6. [Correlation of psychoemotional status and adaptation to complete dentures].

    Science.gov (United States)

    Barkan, I Yu; Stafeev, A A; Repin, V S

    2015-01-01

    Patients with full adentia are characterized by the formation of specific psycho-emotional status. Rational psychotherapeutic support of these patients largely determines the efficiency of dental prosthetic treatment. At the same time, the definition of mental and emotional status is not included in the diagnostic examination protocol. Considering the above the purpose of the study was to evaluate mental and emotional status of patients receiving complete dentures. Prosthetic rehabilitation of 30 patients with complete teeth loss was performed and clinical evaluation and evaluation of mental and emotional status were carried out before and after treatment. Patients with negative experiences of prosthetics showed a higher level of personal and situational anxiety. There was correlation of adaptation to removable dentures and the patient's personality traits. It is determined that emotional instability during treatment tends to decrease affecting the timing of adaptation to complete dentures. It is noted that patients with repeated prosthetics have earlier recovery of coordination ability of the masticatory muscles.

  7. Final-impression techniques and materials for making complete and removable partial dentures.

    Science.gov (United States)

    Jayaraman, Srinivasan; Singh, Balendra P; Ramanathan, Balasubramanian; Pazhaniappan Pillai, Murukan; MacDonald, Laura; Kirubakaran, Richard

    2018-04-04

    Endentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life. To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL. We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the

  8. Comparison of changes in vertical dimension of the upper and lower complete dentures processed using two investing methods

    International Nuclear Information System (INIS)

    Kharat, D.U.; Fakiha, Z.

    1990-01-01

    Standardized compression molding technique was used to process 14 sets of complete dentures. Seven sets of dentures were invested by the conventional method and the other seven were invested by a modified method. In the latter method, the second layer of the investment extended occlusally only up to the maximum convexity on the labial/buccal and lingual surfaces of the teeth. In the beginning, only the upper or the lower denture was processed and changes in the vertical dimension of occlusion were measured. After that, the other denture was also processed and the increase in the vertical dimension of occlusion of the sets of dentures was measured. All measurements were made at the incisal guide pin using a leaf gauge. Statistical analysis using t-test showed no difference in the changes of vertical dimension of the dentures processed by the two different methods of investing. However, both of the methods of investing showed significantly more increase in vertical dimension of the upper complete dentures than that of the lower complete dentures. (author)

  9. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  10. 21 CFR 872.3450 - Ethylene oxide homopolymer and/or karaya denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or karaya denture... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3450 Ethylene oxide homopolymer and/or karaya denture adhesive. (a) Identification. Ethylene oxide homopolymer and/or karaya...

  11. Design of the ZTH vacuum liner

    International Nuclear Information System (INIS)

    Prince, P.P.

    1987-01-01

    The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at 2 MA in 1990 and at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4m major radius and a 40 cm minor radius. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to complete the torus. The thin bellows sections maximize the liner toroidal resistance and the ribs provide support and positional accuracy for the armour in relation to the conducting shell. Heat transfer from the vessel is controlled by a blanket wrap of ceramic fiber insulation and the heat flux is dissipated to a water cooling jacket in the conducting shell. 7 figs., 1 tab

  12. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  13. Axial magnetic field injection in magnetized liner inertial fusion

    Science.gov (United States)

    Gourdain, P.-A.; Adams, M. B.; Davies, J. R.; Seyler, C. E.

    2017-10-01

    MagLIF is a fusion concept using a Z-pinch implosion to reach thermonuclear fusion. In current experiments, the implosion is driven by the Z-machine using 19 MA of electrical current with a rise time of 100 ns. MagLIF requires an initial axial magnetic field of 30 T to reduce heat losses to the liner wall during compression and to confine alpha particles during fusion burn. This field is generated well before the current ramp starts and needs to penetrate the transmission lines of the pulsed-power generator, as well as the liner itself. Consequently, the axial field rise time must exceed hundreds of microseconds. Any coil capable of being submitted to such a field for that length of time is inevitably bulky. The space required to fit the coil near the liner, increases the inductance of the load. In turn, the total current delivered to the load decreases since the voltage is limited by driver design. Yet, the large amount of current provided by the Z-machine can be used to produce the required 30 T field by tilting the return current posts surrounding the liner, eliminating the need for a separate coil. However, the problem now is the field penetration time, across the liner wall. This paper discusses why skin effect arguments do not hold in the presence of resistivity gradients. Numerical simulations show that fields larger than 30 T can diffuse across the liner wall in less than 60 ns, demonstrating that external coils can be replaced by return current posts with optimal helicity.

  14. Design and construction of the liner plate for the Arkansas and Midland containments

    International Nuclear Information System (INIS)

    Wiedner, K.; Shah, G.H.; Chang-Lo, P.

    1976-01-01

    This paper presents the design criteria and features of the containment liner plate systems utilized for the Arkansas and Midland Nuclear Power Plant. For the Arkansas project, the liner plate system was erected in circumferential rings approximately 3 m high, and the penetration assemblies were welded into the liner after erection. For the Midland project, the liner plate system was erected in vertical segments approximately 6 m wide x 24 m high, and the penetration assemblies were welded into the liner prior to erection. The differences between the schemes are discussed. (author)

  15. Routing and scheduling and fleet management for liner shipping

    DEFF Research Database (Denmark)

    Kjeldsen, Karina Hjortshøj

    2009-01-01

    The problem of routing, scheduling and fleet management in global liner shipping is presented. The developed model incorporates the ships' speed as a decision variable. Furthermore, the model must be able to handle problems of the size and complexity experienced by the global liner shipping...

  16. Leakage Performance of the GM + CCL Liner System for the MSW Landfill

    Directory of Open Access Journals (Sweden)

    Fan Jingjing

    2014-01-01

    Full Text Available The contaminants in the landfill leachate press pose a grave threat to environment of the soil and the groundwater beneath the landfill. Despite there being strict requirements in relevant provisions of both domestic and foreign countries for the design of the bottom liner system. Pollution of the soil and the groundwater still took place in a number of landfills because of the leakage. To investigate the leakage rate of the liner systems, the minimum design requirements of the liner systems are summarized according to the provisions of four countries, including China, USA, Germany, and Japan. Comparative analyses using one-dimensional transport model are conducted to study the leakage performance of these liner systems composed of geomembrance (GM and compacted clay layer (CCL meeting the relevant minimum design requirements. Then parametric analyses are conducted to study the effects of the hydraulic head, the thickness of GM, the hydraulic conductivity of CCL, and so forth on the leakage performance of the liner system. It is concluded that the liner system designed according to the minimum design requirements of Germany provide the best antileakage performance, while that of Japan performs the lowest. The key parameters affecting the failure time of the liner system are summarized. Finally, some suggestions for the design of the liner systems are made according to the analyses.

  17. Corrosion failure of a BWR embedded reactor containment liner

    International Nuclear Information System (INIS)

    Wegemar, B.

    2006-01-01

    Following sixteen fuel cycles, leakage through a BWR embedded reactor containment liner (carbon steel) was discovered. Leakage was located at a penetration for electrical conductors as a result of penetrating corrosion attack. During construction, porous cement structures and air pockets/cavities were formed due to erroneous injection of grout. Corrosion attacks on the CS steel liner were located at the relatively small, active surfaces in contact with the porous cement structure. The corrosion mechanism was supposed to be anodic dissolution of the steel liner in areas with insufficient passivation. The penetrations were restored according to original design requirements. (author)

  18. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures.

    NARCIS (Netherlands)

    Creugers, N.H.J.; Witter, D.J.; Spijker, A. van 't; Gerritsen, A.E.; Kreulen, C.M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches

  19. Liner Service Network Design

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard

    . The research field of liner shipping network design is relatively young and many open research questions exists. Among others, a unified and rich mathematical model formulating the main characteristics of the business domain has not been clearly described and exact methods for such mathematical models...... management is of great concern to liner shippers as 70-80% of vessel round trips experience delays in at least one port. A novel mathematical model for handling a disruption using a series of recovery techniques is presented as the The Vessel Schedule Recovery Problem. The model has been applied to four real...... is based upon improving the constructed solution by applying an IP model as a large scale neighbourhood to each service in the network. The IP is based on estimating the benefit of inserting and removing port calls within a predefined neighborhood of candidate ports. Furthermore, the heuristic applies...

  20. [Occlusal schemes of complete dentures--a review of the literature].

    Science.gov (United States)

    Tarazi, E; Ticotsky-Zadok, N

    2007-01-01

    Occlusal scheme is defined as the form and the arrangement of the occlusal contacts in natural and artificial dentition. The choice of an occlusal scheme will determine the pattern of occlusal contacts between opposing teeth during centric relation and functional movement of the mandible. With dentures, the quantity and the intensity of these contacts determine the amount and the direction of the forces that are transmitted through the bases of the denture to the residual ridges. That is why the occlusal scheme is an important factor in the design of complete dentures. Three occlusal schemes are viewed in this review: bilateral balanced occlusion, monplane occlusion, and linear occlusion scheme. Each scheme represents a different concept of occlusion. Comparisons between these schemes are also reviewed and analyzed. The reasoning underlying the bilateral balanced occlusion scheme is that stability of the dentures is attained when bilateral contacts exist throughout all dynamic and static states of the denture during function. Anatomic teeth are used: the upper anterior teeth are set to satisfy aesthetics, and the posterior teeth are arranged in a compensatory curve and a medial curve. This scheme is adequate for well developed residual ridges, with skeletal class I relation. With highly resorbed residual ridges, the vectors of force that are transmitted through anatomic cusps will dislodge the lower denture and thus impair the comfort and efficiency of mastication experienced by the patient. In order to accommodate to the special needs posed by highly resorbed residual ridges and skeletal relations that are not class I, the monoplane scheme of occlusion was designed. This scheme consists of non anatomic (cuspless) teeth, which are set so that the anterior teeth provide the aesthetics, the premolars and the first molars are used for chewing, and the second molars do not occlude (although sometimes they are specifically used to establish bilateral contacts in lateral

  1. DT ignition in a Z pinch compressed by an imploding liner

    International Nuclear Information System (INIS)

    Bilbao, L.; Bernal, L.; Linhart, J.G.; Verri, G.

    2001-01-01

    It has been shown that an m=0 instability of a Z pinch carrying a current of the order of 10 MA with a rise time of less than 10 ns can generate a spark capable of igniting a fusion detonation in the adjacent DT plasma channel. A possible method for generating such currents, necessary for the implosion of an initial large radius, low temperature Z pinch, can be a radial implosion of a cylindrical fast liner. The problem has been addressed in previous publications without considering the role played by an initially impressed m=0 perturbation, a mechanism indispensable for the generation of a spark. The liner-Z pinch dynamics can be solved at several levels of physical model completeness. The first corresponds to a zero dimensional model in which the liner has a given mass per unit length and a zero thickness, the plasma is compressed adiabatically and is isotropic, and there are no energy losses or Joule heating. The second level is one dimensional. The Z pinch plasma is described by the full set of MHD, two-fluid equations. The liner is treated first as thin and incompressible, and subsequently it is assumed that it has a finite thickness and is composed of a heavy ion plasma, having an artificial but realistic equation of state. Both plasma and liner are considered uniform in the Z direction and only DT reactions are considered. It is shown that, given sufficient energy and speed of the liner, the Z pinch can reach a volume ignition. The third level is two dimensional. Plasma and liner are treated as in the second level but either the Z pinch or the liner is perturbed by an m=0 non-uniformity. Provided the liner energy is high enough and the initial m=0 perturbation is correctly chosen, the final neck plasma can act as a spark for DT ignition. It is also shown that the liner energy required for generating a spark and the subsequent detonation propagation are considerably less than in the case of volume ignition. (author)

  2. Formation of Imploding Plasma Liners for HEDP and MIF Applications - Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Gilmore, Mark [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Electrical and Computer Engineering. Dept. of Physics and Astronomy; Hsu, Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Witherspoon, F. Douglas [HyperV Technologies Corp., Chantilly, VA (United States); Cassibry, Jason [Univ. of Alabama, Huntsville, AL (United States); Bauer, Bruno S. [Univ. of Nevada, Reno, NV (United States)

    2015-04-27

    The goal of the plasma liner experiment (PLX) was to explore and demonstrate the feasibility of forming imploding spherical plasma liners that can reach High Energy Density (HED)-relevant (~ 0.1 Mbar) pressures upon stagnation. The plasma liners were to be formed by a spherical array of 30 – 36 railgun-driven hypervelocity plasma jets (Mach 10 – 50). Due to funding and project scope reductions in year two of the project, this initial goal was revised to focus on studies of individual jet propagation, and on two jet merging physics. PLX was a collaboration between a number of partners including Los Alamos National Laboratory, HyperV Technologies, University of New Mexico (UNM), University of Alabama, Huntsville, and University of Nevada, Reno. UNM’s part in the collaboration was primary responsibility for plasma diagnostics. Though full plasma liner experiments could not be performed, the results of single and two jet experiments nevertheless laid important groundwork for future plasma liner investigations. Though challenges were encountered, the results obtained with one and two jets were overwhelmingly positive from a liner formation point of view, and were largely in agreement with predictions of hydrodynamic models.

  3. [Selection of occlusal scheme on the basis of pressure distribution on supporting structures under complete dentures].

    Science.gov (United States)

    Nagao, Kan; Kawano, Fumiaki; Ichikawa, Tetsuo

    2004-12-01

    In case of making complete dentures, we have to consider not only denture stability but also the restoration of aesthetics and function such as mastication and speech. However these are contradictory theoretically from the point of view of denture stability, and it is very difficult to satisfy both requirements in the case of a patient who has poor upper and lower alveolar ridges. We investigated the effect of artificial posterior teeth form and occlusal scheme on the distribution of pressure on supporting structures under complete dentures during mastication with upper and lower edentulous simulators. In this report, a guideline for the selection of occlusal scheme for complete dentures, based on our previous investigations, is described. The occlusal scheme remarkably affected the distribution of pressure under simulated complete dentures, as shown by comparing the distribution of pressure using two different occlusal schemes:fully balanced occlusion and lingualized occlusion. However other factors such as posterior teeth form and position affect the distribution of pressure as well, and are related to each other. Therefore, not only occlusal scheme but also posterior artificial teeth form has to be considered, and the form of posterior teeth should be carefully and comprehensively decided when making complete dentures.

  4. Accurate control testing for clay liner permeability

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, R J

    1991-08-01

    Two series of centrifuge tests were carried out to evaluate the use of centrifuge modelling as a method of accurate control testing of clay liner permeability. The first series used a large 3 m radius geotechnical centrifuge and the second series a small 0.5 m radius machine built specifically for research on clay liners. Two permeability cells were fabricated in order to provide direct data comparisons between the two methods of permeability testing. In both cases, the centrifuge method proved to be effective and efficient, and was found to be free of both the technical difficulties and leakage risks normally associated with laboratory permeability testing of fine grained soils. Two materials were tested, a consolidated kaolin clay having an average permeability coefficient of 1.2{times}10{sup -9} m/s and a compacted illite clay having a permeability coefficient of 2.0{times}10{sup -11} m/s. Four additional tests were carried out to demonstrate that the 0.5 m radius centrifuge could be used for linear performance modelling to evaluate factors such as volumetric water content, compaction method and density, leachate compatibility and other construction effects on liner leakage. The main advantages of centrifuge testing of clay liners are rapid and accurate evaluation of hydraulic properties and realistic stress modelling for performance evaluations. 8 refs., 12 figs., 7 tabs.

  5. [Elderly people and removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de

    2009-01-01

    The most frequently reported disadvantages of removable partial dentures are the more demanding daily oral hygiene self-care, especially for people who already experience difficulties in self-care, and the possible harmful influence on the remaining dentition. These disadvantages can be expressed in

  6. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials.

    Science.gov (United States)

    Zafar, Muhammad Sohail; Ahmed, Naseer

    2014-01-01

    Polymers have a wide range of applications in dentistry. Poly methyl methacrylate (PMMA) is the most popular for making orthodontic retainers, dentures as well as synthetic teeth. Prior to clinical applications, the appliances are polished in the dental laboratory to achieve smooth, polished and comfortable surfaces. The objective of this study was to analyze the surface roughness profiles of PMMA dentures polished using two different approaches. In addition, the effects of ultrasonication and sandblasting were also evaluated on the fitting surface of PMMA dentures. This was an in vitro study using non-contact mode surface roughness profilometer and nano-indenter. Samples were polished using two different techniques (Standard and modified). Both cold cure and heat cure PMMA denture surfaces were evaluated for roughness, nanohardness and elastic modulus. The absolute hardness was recorded 297.72±19.04 MPa and 229.93±18.53 MPa for heat cured PMMA and cold cured PMMA. Manufactured acrylic teeth were harder (319.20±12.58 MPa) with an elastic modulus of (4.34±1.86 GPa). Modified polishing techniques (group 3) produced smoother surface. It was concluded that elastic moduli of acrylic tooth and heat cure PMMA is not very different. Surface treatments such as ultrasonication or sandblasting do not affect the roughness profiles of denture fitting surfaces.

  7. Implant overdentures: dental students' performance in fabrication, denture quality, and patient satisfaction.

    Science.gov (United States)

    Aragon, Cecilia E; Cornacchio, Angelica Lee Petrina; Ibarra, Lilia Marcela; Saad, Muhammed N; Zibrowski, Elaine

    2010-09-01

    The purpose of this study was to evaluate dental students' performance when fabricating a mandibular two-implant overdenture (OD) as compared to conventional dentures (CD) and to determine if these prostheses were successful. Twenty students and twenty patients were divided into two groups: complete denture group (CDG) and maxillary denture and two-implant OD group (ODG). Students' progress was evaluated at each appointment as they were given a clinical assessment score (CAS), which varied from 1 (unacceptable, needs to repeat procedure) to 4 (acceptable, no errors). The success of the prosthesis was evaluated by the patients using a visual analog scale (VAS) and an expert (a prosthodontist) using a denture quality assessment (DQA) form. Performance for both groups was not statistically different across all eight appointments (CDG 3.16 versus ODG 3.25; p=0.46). Patients with ODs reported greater stability with their dentures (p=0.048) and greater ability to chew than patients with CDs (p=0.03). There were no differences between the groups in terms of expert appraisal (ODG 71.1 versus CDG 67.5; p=0.59). The performance of dental students when fabricating a two-implant OD is thus not different from that of a CD. Students can successfully fabricate a two-implant OD as perceived by both patients and prosthodontists.

  8. The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.

    Science.gov (United States)

    Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela

    2018-04-01

    To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.

  9. A Base Integer Programming Model and Benchmark Suite for Liner-Shipping Network Design

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard; Alvarez, Fernando; Plum, Christian Edinger Munk

    2014-01-01

    . The potential for making cost-effective and energy-efficient liner-shipping networks using operations research (OR) is huge and neglected. The implementation of logistic planning tools based upon OR has enhanced performance of airlines, railways, and general transportation companies, but within the field......The liner-shipping network design problem is to create a set of nonsimple cyclic sailing routes for a designated fleet of container vessels that jointly transports multiple commodities. The objective is to maximize the revenue of cargo transport while minimizing the costs of operation...... sources of liner shipping for OR researchers in general. We describe and analyze the liner-shipping domain applied to network design and present a rich integer programming model based on services that constitute the fixed schedule of a liner shipping company. We prove the liner-shipping network design...

  10. A Study of Market Structure in Liner Shipping Under the Influence of Government Policies

    OpenAIRE

    Wong, Peter Chi Chung; Bamford, Colin

    2012-01-01

    The peculiar operational mode and involvement of international carriers\\ud granted liner operators special exemption from Anti-trust regulations\\ud globally. The changes of policy from USA and EU in recent years forbidden\\ud liner operators to form Liner Conference (LC) which seems to possess\\ud oligopoly power in the trade. This paper use the freight rate to verified the\\ud change of Government policies cannot stop the liner operators to form in\\ud their natural formation - Liner Conference.

  11. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Science.gov (United States)

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  12. 21 CFR 872.3410 - Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or....3410 Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive. (a) Identification. An ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive is a device...

  13. Complete Denture Impression Techniques Practiced by Private Dental Practitioners: A Survey

    OpenAIRE

    Kakatkar, Vinay R.

    2012-01-01

    Impression making is an important step in fabricating complete dentures. A survey to know the materials used and techniques practiced while recording complete denture impressions was conducted. It is disheartening to know that 33 % practitioners still use base plate custom trays to record final impressions. 8 % still use alginate for making final impressions. An acceptable technique for recording CD impressions is suggested.

  14. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    Science.gov (United States)

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and pCAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental

  15. Occlusal designs on masticatory ability and patient satisfaction with complete denture: a systematic review.

    Science.gov (United States)

    Zhao, Ke; Mai, Qing-Qing; Wang, Xiao-Dong; Yang, Wen; Zhao, Li

    2013-11-01

    To systematically review clinical outcomes of different occlusal designs of complete dentures. Using a various key words, an electronic search of clinical trials published in English and Chinese literature was performed from four databases: Medline/PubMed, EMBASE, Cochrane Library, and CBM. Furthermore, a manual searching of the relevant journals and the bibliographies of reviews was performed. General satisfaction, masticatory ability, retention, and stability were major criteria for the evaluation of the outcomes. Studies met these criteria were selected for a full-text reading. The whole processes were performed by two reviewers independently. This systematic review started with 1030 articles, which were finally narrowed down to seven, according to the inclusion criteria. The following occlusal designs were included and analyzed: anatomic occlusion, balanced occlusion, canine guidance occlusion, lingualized occlusion, monoplane occlusion, and bilateral-balanced and canine-guided design. Three of the seven studies showed that lingualized occlusion had ratings of higher patients' satisfaction than other occlusion designs. On the other hand, the canine-guided occlusion dentures demonstrated equal or better clinical performances than bilateral-balanced dentures. Because of the heterogeneity and bias of the studies, it was not possible to analyze the data statistically. Lingualized occlusion and canine-guided occlusion can be successfully applied in the fabrication of complete dentures. Canine guided occlusion has also been shown to be satisfactory. More well-controlled randomized trials are needed regarding canine-guided occlusion and the relationship between alveolar ridge resorption, different occlusal schemes and patient satisfaction. The conventional prosthodontic wisdom that complete dentures require a balanced occlusal design is not supported by the included literature. A suitable occlusal scheme would be a critical factor for a successful complete denture

  16. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    Science.gov (United States)

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  17. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    Science.gov (United States)

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  18. Kinesiographic study of complete denture movement related to mucosa displacement in edentulous patients Estudo cinesiográfico da movimentação da prótese total resultante da deformação da fibromucosa em desdentados totais

    Directory of Open Access Journals (Sweden)

    Marco Antonio Compagnoni

    2003-12-01

    Full Text Available The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System® was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A 3 maximum voluntary clenching cycles and (B unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.Devido às características de compressibilidade da fibromucosa, a incidência de cargas sobre a prótese total resulta na movimentação da prótese em direção ao rebordo, a qual pode resultar no aumento da reabsorção do rebordo residual, na desadaptação interna e na perda de retenção da prótese. O objetivo do presente estudo é avaliar o padrão de movimentação da prótese total superior em função da deformação da fibromucosa. Foram selecionados 10 pacientes usuários de próteses totais bimaxilares, com retenção satisfatória e relações oclusais corretas e rebordos alveolares com volume e grau de resiliência normais. Para a análise da movimentação da prótese total superior foi

  19. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction.

    Science.gov (United States)

    Salloum, Alaa'a M

    2016-01-01

    Tooth movement has been shown to occur during and after the processing of complete dentures. An understanding of this phenomenon may permit one to construct functional complete dentures that require less occlusal adjustment in the articulator and in the patient's mouth. The purpose of this study was to examine the effects of three different investing methods on tooth movement occurring during the processing of simulated maxillary complete dentures. Forty-five similar maxillary dentures were made using heat-polymerized acrylic resin, and assigned randomly to three experimental groups (n = 15 each) according to investing method: plaster-plaster-plaster (P-P-P), plaster-stone-stone (P-S-S), and plaster-mix (P-M). Specimens in all experimental groups were compression molded with denture base resin. Transverse interincisor (I-I) and intermolar (M-M) distances, and anteroposterior incisor-molar (LI-LM and RI-RM) distances, were measured with digital calipers at the wax denture stage (pre-polymerization) and after denture decasting (post-polymerization). Analysis of variance and Tukey's test were used to compare the results. M-M, LI-LM, and RI-RM movement was significantly greater in the P-P-P group than in the P-S-S and P-M groups; no significant difference in I-I movement was observed among groups. Transverse movement along M-M and I-I was significantly greater than anteroposterior movement in the P-P-P group; no significant difference among measurements was observed in the other two groups. The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement.

  20. Analysis of Dual Mobility Liner Rim Damage Using Retrieved Components and Cadaver Models.

    Science.gov (United States)

    Nebergall, Audrey K; Freiberg, Andrew A; Greene, Meridith E; Malchau, Henrik; Muratoglu, Orhun; Rowell, Shannon; Zumbrunn, Thomas; Varadarajan, Kartik M

    2016-07-01

    The objective of this study was to assess the retentive rim of retrieved dual mobility liners for visible evidence of deformation from femoral neck contact and to use cadaver models to determine if anterior soft tissue impingement could contribute to such deformation. Fifteen surgically retrieved polyethylene liners were assessed for evidence of rim deformation. The average time in vivo was 31.4 months, and all patients were revised for reasons other than intraprosthetic dislocation. Liner interaction with the iliopsoas was studied visually and with fluoroscopy in cadaver specimens using a dual mobility system different than the retrieval study. For fluoroscopic visualization, a metal wire was sutured to the iliopsoas and wires were also embedded into grooves on the outer surface of the liner and the inner head. All retrievals showed evidence of femoral neck contact. The cadaver experiments showed that liner motion was impeded by impingement with the iliopsoas tendon in low flexion angles. When observing the hip during maximum hyperextension, 0°, 15°, and 30° of flexion, there was noticeable tenting of the iliopsoas caused by impingement with the liner. Liner rim deformation resulting from contact with the femoral neck likely begins during early in vivo function. The presence of deformation is indicative of a mechanism inhibiting mobility of the liner. The cadaver studies showed that liner motion could be impeded because of its impingement with the iliopsoas. Such soft tissue impingement may be one mechanism by which liner motion is routinely inhibited, which can result in load transfer from the neck to the rim. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  2. Calculation of anchor forces on penetration liners for the reactor vessel Schmehausen (Germany)

    International Nuclear Information System (INIS)

    Roennert, J.K.

    1976-01-01

    Penetrations through the walls of the single cavity PCPV Prestressed Concrete Pressure Vessel for the 300 MW(e) reactor are lined with steel penetration liners welded to the liner of the cavity. For gas-tightness of the system the penetrations are closed by covers. To secure their integration with the concrete, the liners are anchored to it by means of shear studs and/or angles. Being embedded in concrete, over the full width of the walls, the liners are exposed to lateral and longitudinal concrete deformations causing forces on the anchors. The axial blow-out force due to the pressure of the coolant on the closures must also be transferred through the anchors to the concrete. In the design of anchored penetration liners stress analyses are performed to determine anchor forces under different loading conditions and at several ages of the PCPV. The present paper deals with the mathematical estimation of the anchor forces on the basis of given concrete deformations, temperature of liners, and pressure in the vessel by the method of replacing the penetration liners and their anchors by a spring model with linear stiffness characteristics for both the liner and the anchors. An example of the computations on a digital computer is shown. (author)

  3. A three-dimensional rupture analysis of steel liners anchored to concrete pressure and containment vessels

    International Nuclear Information System (INIS)

    Bangash, Y.

    1987-01-01

    Steel liners or plates are anchored to concrete pressure and containment vessels for nuclear and offshore facilities. Due to extreme loading conditions a liner may buckle due to the pull-out or shearing of anchors from the base metal and concrete. Under certain conditions attributed to loadings, liner metal deterioration and cracking of concrete behind the liner, the liner may fail by rupture. This paper presents a three-dimensional analysis of steel-concrete elements, using finite elements analysis in which a provision is made for liner instability, anchor strength and stiffness, concrete cracking and finally liner rupture. The analysis is tested first on an octagonal slab with and without an anchored steel liner. It is then extended to concrete pressure and containment vessels. The analytical results obtained are compared well with those available from the experimental tests and other sources. (author)

  4. Consideration of liners and covers in performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, Mark A. [Savannah River National Laboratory, Aiken, SC (United States); Seitz, Robert R. [Savannah River National Laboratory, Aiken, SC (United States); Suttora, Linda C. [USDOE Enviromental Management, Washington, DC (United States)

    2014-09-18

    On-site disposal cells are in use and being considered at several United States Department of Energy (USDOE) sites as the final disposition for large amounts of waste associated with cleanup of contaminated areas and facilities. These disposal cells are typically regulated by States and/or the U.S. Environmental Protection Agency under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) in addition to having to comply with requirements in DOE Order 435.1, Radioactive Waste Management due to the radioactive waste. The USDOE-Environmental Management Office of Site Restoration formed a working group to foster improved communication and sharing of information for personnel associated with these CERCLA disposal cells and work towards more consistent assumptions, as appropriate, for technical and policy considerations related to CERCLA risk assessments and DOE Order 435.1 performance assessments in support of a Record of Decision and Disposal Authorization Statement, respectively. One of the issues considered by the working group, which is addressed in this report, was how to appropriately consider the performance of covers and liners/leachate collections systems in the context of a DOE Order 435.1 performance assessment (PA). This same information may be appropriate for consideration within CERCLA risk assessments for these facilities. These OSDCs are generally developed to meet hazardous waste (HW) disposal design standards under the Resource Conservation and Recovery Act (RCRA) as well as the DOE Order 435.1 performance based standards for disposal of radioactive waste. To meet the standards for HW, the facilities typically include engineered covers and liner/leachate collection systems. Thus, when considering such facilities in the context of a DOE Order 435.1 PA, there is a need to address the evolution of performance of covers and liner/leachate collection systems in the context of meeting a performance standard considering time

  5. Evaluation of flexible membrane liners as long-term barriers for uranium mill tailings

    International Nuclear Information System (INIS)

    1984-07-01

    The National Uranium Tailings Program has commissioned a study to evaluate flexible membrane liners (geomembranes) as long-term barriers for Canadian uranium mill tailings. This study reviews the common liner type and addresses flexible liners (polymeric membranes and asphalt) in detail. Liner fabrication, design, installation, and performance are reviewed. Conceptual designs are presented for basins to accommodate 20 years accumulation of uranium tailings from mills in Elliot Lake and southeastern Athabasca. Nine polymeric and three asphalt liner types have been considered with respect to the physical and chemical environment in the uranium producing areas of Canada. All materials indicate good chemical resistance to uranium wastes but are subject to installation problems

  6. Strength analyses of containment steel liner at the plasticity instability

    International Nuclear Information System (INIS)

    Klyashchitskij, V.I.; Golyakov, V.I.; Kostylev, V.I.; Margolin, B.Z.

    2003-01-01

    The steel liner of NPP containment plays the important role of a leak-tight contour preventing the possible releases of radioactive substances beyond the boundaries of the reactor building. However, so far in many cases an assessment of strain-stress state of the liner having initial imperfections of the shape was made with approximate methods. A new methodology for the analysis of the liner at the plasticity instability was developed at Atomenergoproekt institute in cooperation with specialists from other agencies. The methodology is based on code 'Termit'. Assessment of the critical strain was made taking into account possible presence of one or two defects: construction undercut or crack-like defect in a weld. On the base of the real structure analyses under any combinations of quasi-static loads the algorithm was developed for the computation of the liner. (author)

  7. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    Science.gov (United States)

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  8. Tissue Friendly Pendulum: Soft Liner to prevent Tissue Irritation

    Directory of Open Access Journals (Sweden)

    Siddharth Shashidhar Revankar

    2014-01-01

    Full Text Available Palatal mucosal irritation is commonly encountered with the Pendulum appliance. The efficiency of soft liners in reducing tissue irritation has been well documented in the field of prosthodontics. The following article describes an innovative technique where soft liner can be used to reduce palatal mucosal irritation caused by pendulum appliance.

  9. Deuterium Liner and Multiparameter Investigation of the Inverse Z-Pinch Formation Process

    CERN Document Server

    Bystritskii, Vyach M; Grebenyuk, V M; Parzhitsky, S S; Penkov, F M; Stolupin, V A; Boznyak, J; Gula, E; Dudkin, G N; Nechaev, B A; Padalko, V M; Mesyats, G A; Ratakhin, N A; Sorokin, S A

    2001-01-01

    A description of the methods and results of the measurements of the ion energy distribution of the deuterium liner accelerated in the inverse Z-pinch configuration are presented - the liner plasma is radially accelerated from the outward small radius. The knowledge of the experiment deuteron energy distribution is crucially important for correct interpretation of the results on the study of the dd-reaction at infralow collision energies using the liner plasma. Experiments were fulfilled in the HCEI (Tomsk, Russia) at a nanosecond pulsed high current generator (I=950 kA, pulse duration \\tau=80 ns). The hollow deuterium liner of 20 mm length was accelerated from the initial radius of \\sim 15 mm to 45 mm. Measurement of the liner characteristics was produced by means of the light detectors (detection of H_\\alpha and H_\\beta deuterium lines) and magnetic B-dot probes, placed on the various radii of the expanding liner. Besides, the measurement of the neutron radiation intensity due to reaction d+d\\to^{3}He+n was ...

  10. Influence of balanced occlusion in complete dentures on the decrease in reduction of an edentulous ridge

    Directory of Open Access Journals (Sweden)

    Poštić Srđan D.

    2012-01-01

    Full Text Available Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal study on 91 fully edentulous patients was conducted using their panoramic radiographs and parameters of vertical dimension of edentulous ridges. All the patients were clinically examined by the same and a qualified dental practitioner. Numerical values of parameters of vertical dimensions of edentulous ridges and lines were statistically processed and compared using the Student’s t-test. Results. Vertical dimensions and heights of edentulous ridges were different after comparison of parameters in complete denture wearers with balanced occlusion and complete denture wearers without bilaterally balanced occlusion, as well as between male and female edentulous patients. Statistically significant differences of heights were established in complete denture wearers’ with a set of artificial teeth without balanced occlusion, at the baseline and 12 months after wearing of complete dentures. Conclusion. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional complete dentures, which preserves edentulous ridge and influence the stability of dentures.

  11. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction.

    Science.gov (United States)

    Wismeijer, Daniel; Tawse-Smith, Andrew; Payne, Alan G T

    2013-01-01

    To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. Forty-eight participants who were dissatisfied with their existing conventional mandibular distal extension dentures opposing complete maxillary dentures were selected for a multicentre prospective study in New Zealand, Colombia and the Netherlands. A control group of 12 participants in New Zealand received conventional mandibular partial dentures. Three test groups involving 36 participants in New Zealand (12), Colombia (12) and the Netherlands (12) received bilateral distal implants in the second molar regions. After conventional loading, the test group participants initially had healing caps placed on the distal implants providing support only, followed after approximately 6 months by ball abutments (retentive anchors) for support and retention. Patient outcomes were determined with questionnaires completed at specific stages of the study for up to 3 years. Visual analogue scale, Likert and oral health impact questionnaires before and after treatment indicated improved results. There were significantly improved parameters of overall satisfaction, stability, chewing and appearance after 3 years (P removable partial dentures are a preferable treatment option for patients with complaints about their conventional distal extension partial dentures. © 2011 John Wiley & Sons A/S.

  12. Nuclear containment steel liner corrosion workshop : final summary and recommendation report.

    Energy Technology Data Exchange (ETDEWEB)

    Erler, Bryan A. (Erler Engineering Ltd., Chicago, IL); Weyers, Richard E. (Virginia Tech University, Blacksburg, VA); Sagues, Alberto (University of South Florida, Tampa, FL); Petti, Jason P.; Berke, Neal Steven (Tourney Consulting Group, LLC, Kalamazoo, MI); Naus, Dan J. (Oak Ridge National Laboratory, Oak Ridge, TN)

    2011-07-01

    This report documents the proceedings of an expert panel workshop conducted to evaluate the mechanisms of corrosion for the steel liner in nuclear containment buildings. The U.S. Nuclear Regulatory Commission (NRC) sponsored this work which was conducted by Sandia National Laboratories. A workshop was conducted at the NRC Headquarters in Rockville, Maryland on September 2 and 3, 2010. Due to the safety function performed by the liner, the expert panel was assembled in order to address the full range of issues that may contribute to liner corrosion. This report is focused on corrosion that initiates from the outer surface of the liner, the surface that is in contact with the concrete containment building wall. Liner corrosion initiating on the outer diameter (OD) surface has been identified at several nuclear power plants, always associated with foreign material left embedded in the concrete. The potential contributing factors to liner corrosion were broken into five areas for discussion during the workshop. Those include nuclear power plant design and operation, corrosion of steel in contact with concrete, concrete aging and degradation, concrete/steel non-destructive examination (NDE), and concrete repair and corrosion mitigation. This report also includes the expert panel member's recommendations for future research.

  13. Evaluation of Candida Albicans Biofilm Formation on Various Dental ...

    African Journals Online (AJOL)

    2016-06-24

    Jun 24, 2016 ... This study compared the susceptibility of six dental restorative materials to Candida albicans adhesion. ... found for the composite and the compomer samples. ..... Candida colonization on acrylic resins and denture liners:.

  14. Landing Gear Door Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Howerton, Brian M. (Inventor); Van De Ven, Thomas (Inventor)

    2014-01-01

    A landing gear door for retractable landing gear of aircraft includes an acoustic liner. The acoustic liner includes one or more internal cavities or chambers having one or more openings that inhibit the generation of sound at the surface and/or absorb sound generated during operation of the aircraft. The landing gear door may include a plurality of internal chambers having different geometries to thereby absorb broadband noise.

  15. Competitive Liner Shipping Network Design

    DEFF Research Database (Denmark)

    Karsten, Christian Vad

    .The contributions of this thesis cover modeling, methodology, and applications.The developed methods address operational (cargo routing), tactical (speed optimization and service selection), and strategic (network design) planning problems faced by liner shipping companies. Ultimately, the proposed methods help...... take the container transportation times that can be realized in the network nor the number of transshipments into consideration. This is mainly because the optimization problem is based on other transportation networks where these constraints are not decisive to the quality of the network. Furthermore......, the problem in itself is challenging to optimize due to its size and complexity. However, the field has seen crucial progress and is mature to include handling of competitiveness in the actual design of the network.As a liner shipping network is an organic entity, which is constantly changed to reflect...

  16. Pining for home: Studying crew homesickness aboard a cruise liner ...

    African Journals Online (AJOL)

    Research in Hospitality Management ... Crew homesickness should be seen as important by both shipboard and liner company management because it can ultimately impact on customer service experiences, and can be ameliorated by ... Keywords: homesickness, cruise-liner, crewmembers, shipboard hotel services ...

  17. An Improved Lubrication Model between Piston Rings and Cylinder Liners with Consideration of Liner Dynamic Deformations

    Directory of Open Access Journals (Sweden)

    Guoxing Li

    2017-12-01

    Full Text Available The friction pair of piston rings and cylinder liner is one of the most important friction couplings in an internal combustion engine. It influences engine efficiency and service life. Under the excitation of piston slaps, the dynamic deformation of cylinder liner is close to the surface roughness magnitudes, which can affect the friction and lubrication performance between the piston rings and cylinder assemblies. To investigate the potential influences of structural deformations to tribological behaviours of cylinder assemblies, the dynamic deformation of the inner surface due to pistons slaps is obtained by dynamic simulations, and then coupled into an improved lubrication model. Different from the traditional lubrication model which takes the pressure stress factor and shear stress factor to be constant, the model proposed in this paper calculated these factors in real time using numerical integration to achieve a more realistic simulation. Based on the improved piston rings and cylinder liner lubrication model, the minimum oil film thickness and friction force curves are obtained for an entire work cycle. It shows that the friction force obtained from the improved model manifests clear oscillations in each stoke, which is different from the smoothed profiles predicted traditionally. Moreover, the average amplitude of the friction forces also shows clear reduction.

  18. Super-fast multi-wire liner implosion physics study at Angara-5-1

    Energy Technology Data Exchange (ETDEWEB)

    Alexandrov, V V; Branitsky, A V; Volkov, G S; Fedulov, M V; Grabovsky, E V; Nedoseev, L; Oleinik, G M; Samokhin, A N; Sasorov, F P.V.; Smirnov, V P; Frolov, I N; Zaitzev, V I; Zurin, M V [GSC Troitsk Institute for Innovation and Fusion Research, Troitsk, Moscow region (Russian Federation); Spielman, R B; Deeney, C [Sandia National Labs., Albuquerque, NM (United States)

    2000-07-01

    The temporally dragged plasma production (TDPP) from dense substance of tungsten wire occurs during multi-wire-liner implosion. TDPP is the typical feature of wire liner implosion. In spite of plasma filling of the initial liner cavity, a narrow pulse (up to 6 ns) of X rays is radiated for an 0.3-mm inter-wire gap. (authors)

  19. Super-fast multi-wire liner implosion physics study at Angara-5-1

    International Nuclear Information System (INIS)

    Alexandrov, V.V.; Branitsky, A.V.; Volkov, G.S.; Fedulov, M.V.; Grabovsky, E.V.; Nedoseev, L.; Oleinik, G.M.; Samokhin, A.N.; Sasorov, F.P.V.; Smirnov, V.P.; Frolov, I.N.; Zaitzev, V.I.; Zurin, M.V.; Spielman, R.B.; Deeney, C.

    2000-01-01

    The temporally dragged plasma production (TDPP) from dense substance of tungsten wire occurs during multi-wire-liner implosion. TDPP is the typical feature of wire liner implosion. In spite of plasma filling of the initial liner cavity, a narrow pulse (up to 6 ns) of X rays is radiated for an 0.3-mm inter-wire gap. (authors)

  20. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    OpenAIRE

    Nam, Ki-Young

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transm...

  1. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    Science.gov (United States)

    Nasution, Hubban; Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu

    2018-01-01

    The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets. The modulus of elasticity and nanohardness of each denture base (n=10) were measured on 15×15×15×3mm 3 specimen by using an ultramicroindentation system. The pressure transmission area, modulus of elasticity, and nanohardness data were statistically analyzed with 1-way ANOVA, followed by Tamhane or Tukey HSD post hoc test (α=.05). The maximum pressure transmission data were statistically analyzed with Kruskal-Wallis H test, followed by Mann-Whitney U test (α=.05). Polymethyl methacrylate showed significantly larger pressure transmission area and higher maximum pressure transmission than the other groups (Pelasticity and nanohardness among the four types of denture bases (Pelasticity and nanohardness of each type of denture base were demonstrated. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  2. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles.

    Science.gov (United States)

    Nam, Ki-Young

    2014-06-01

    This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.

  3. Contoured-gap coaxial guns for imploding plasma liner experiments

    Science.gov (United States)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  4. Evaluation of the utility of cephalometric parameters in constructing complete denture. Part I: placement of posterior teeth.

    Science.gov (United States)

    Bassi, F; Deregibus, A; Previgliano, V; Bracco, P; Preti, G

    2001-03-01

    Various types of parameters, including cephalometric ones, have been used in the construction of complete denture. This study aimed to evaluate the utility of cephalometric parameters for this purpose. The position of the posterior teeth in a group of 42 edentulous patients, successfully rehabilitated with complete denture according to clinical parameters, was evaluated by cephalometrics. The following were determined: vertical dimension of occlusion (VDO); orientation of the occlusal plane; and subdivision of the denture space. The cephalometric parameters do not correspond to the clinical positioning of the posterior teeth in successful rehabilitation with complete denture.

  5. An integer programming model and benchmark suite for liner shipping network design

    DEFF Research Database (Denmark)

    Løfstedt, Berit; Alvarez, Jose Fernando; Plum, Christian Edinger Munk

    effective and energy efficient liner shipping networks using operations research is huge and neglected. The implementation of logistic planning tools based upon operations research has enhanced performance of both airlines, railways and general transportation companies, but within the field of liner......Maritime transportation is accountable for 2.7% of the worlds CO2 emissions and the liner shipping industry is committed to a slow steaming policy to provide low cost and environmentally conscious global transport of goods without compromising the level of service. The potential for making cost...... along with a rich integer programming model based on the services, that constitute the fixed schedule of a liner shipping company. The model may be relaxed as well as decomposed. The design of a benchmark suite of data instances to reflect the business structure of a global liner shipping network...

  6. Progress In Magnetized Target Fusion Driven by Plasma Liners

    Science.gov (United States)

    Thio, Francis Y. C.; Kirkpatrick, Ronald C.; Knapp, Charles E.; Cassibry, Jason; Eskridge, Richard; Lee, Michael; Smith, James; Martin, Adam; Wu, S. T.; Schmidt, George; hide

    2001-01-01

    Magnetized target fusion (MTF) attempts to combine the favorable attributes of magnetic confinement fusion (MCF) for energy confinement with the attributes of inertial confinement fusion (ICF) for efficient compression heating and wall-free containment of the fusing plasma. It uses a material liner to compress and contain a magnetized plasma. For practical applications, standoff drivers to deliver the imploding momentum flux to the target plasma remotely are required. Spherically converging plasma jets have been proposed as standoff drivers for this purpose. The concept involves the dynamic formation of a spherical plasma liner by the merging of plasma jets, and the use of the liner so formed to compress a spheromak or a field reversed configuration (FRC).

  7. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  8. Classification of Ship Routing and Scheduling Problems in Liner Shipping

    DEFF Research Database (Denmark)

    Kjeldsen, Karina Hjortshøj

    2011-01-01

    This article provides a classification scheme for ship routing and scheduling problems in liner shipping in line with the current and future operational conditions of the liner shipping industry. Based on the classification, the literature is divided into groups whose main characteristics...

  9. Acoustic Panel Liner for an Engine Nacelle

    Science.gov (United States)

    Jones, Michael G. (Inventor); Nark, Douglas M. (Inventor); Ayle, Earl (Inventor); Ichihashi, Fumitaka (Inventor)

    2016-01-01

    An acoustic panel liner includes a face sheet, back plate, and liner core positioned there-between, which may be used in an engine nacelle. Elongated chambers contain variable amounts of septa at a calibrated depth or depths. The septa may have varying DC flow resistance. The chambers may have a hexagonal or other polygonal cross sections. The septa, such as mesh caps, may be bonded to an inner wall of a corresponding chamber. The insertion depths may be the same or different. If different, the pattern of distribution of the depths may be randomized.

  10. A Finite Element Theory for Predicting the Attenuation of Extended-Reacting Liners

    Science.gov (United States)

    Watson, W. R.; Jones, M. G.

    2009-01-01

    A non-modal finite element theory for predicting the attenuation of an extended-reacting liner containing a porous facesheet and located in a no-flow duct is presented. The mathematical approach is to solve separate wave equations in the liner and duct airway and to couple these two solutions by invoking kinematic constraints at the facesheet that are consistent with a continuum theory of fluid motion. Given the liner intrinsic properties, a weak Galerkin finite element formulation with cubic polynomial basis functions is used as the basis for generating a discrete system of acoustic equations that are solved to obtain the coupled acoustic field. A state-of-the-art, asymmetric, parallel, sparse equation solver is implemented that allows tens of thousands of grid points to be analyzed. A grid refinement study is presented to show that the predicted attenuation converges. Excellent comparison of the numerically predicted attenuation to that of a mode theory (using a Haynes 25 metal foam liner) is used to validate the computational approach. Simulations are also presented for fifteen porous plate, extended-reacting liners. The construction of some of the porous plate liners suggest that they should behave as resonant liners while the construction of others suggest that they should behave as broadband attenuators. In each case the finite element theory is observed to predict the proper attenuation trend.

  11. Failure mechanisms and closed reduction of a constrained tripolar acetabular liner.

    Science.gov (United States)

    Robertson, William J; Mattern, Christopher J; Hur, John; Su, Edwin P; Pellicci, Paul M

    2009-02-01

    Unlike traditional bipolar constrained liners, the Osteonics Omnifit constrained acetabular insert is a tripolar device, consisting of an inner bipolar bearing articulating within an outer, true liner. Every reported failure of the Omnifit tripolar implant has been by failure at the shell-bone interface (Type I failure), failure at the shell-liner interface (Type II failure), or failure of the locking mechanism resulting in dislocation of the bipolar-liner interface (Type III failure). In this report we present two cases of failure of the Omnifit tripolar at the bipolar-femoral head interface. To our knowledge, these are the first reported cases of failure at the bipolar-femoral head interface (Type IV failure). In addition, we described the first successful closed reduction of a Type IV failure.

  12. Present status of titanium removable dentures--a review of the literature.

    Science.gov (United States)

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  13. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... 2Faculty of Dentistry, the University of Hong Kong, Hong Kong. 3Department of ... an example of poor oral condition caused mainly by periodontitis, and ... working model of the Dual Component Removable Partial Denture.

  14. Flap Side Edge Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Khorrami, Mehdi R. (Inventor); Choudhari, Meelan M. (Inventor); Howerton, Brian M. (Inventor)

    2014-01-01

    One or more acoustic liners comprising internal chambers or passageways that absorb energy from a noise source on the aircraft are disclosed. The acoustic liners may be positioned at the ends of flaps of an aircraft wing to provide broadband noise absorption and/or dampen the noise producing unsteady flow features, and to reduce the amount of noise generated due to unsteady flow at the inboard and/or outboard end edges of a flap.

  15. Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins

    Directory of Open Access Journals (Sweden)

    Nour M. Ajaj-ALKordy

    2014-01-01

    Conclusion: Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.

  16. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    Science.gov (United States)

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  17. Improved Broadband Liner Optimization Applied to the Advanced Noise Control Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.; Sutliff, Daniel L.; Ayle, Earl; Ichihashi, Fumitaka

    2014-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more desirable. This paper describes improvements to a previously established broadband acoustic liner optimization process using the Advanced Noise Control Fan rig as a demonstrator. Specifically, in-duct attenuation predictions with a statistical source model are used to obtain optimum impedance spectra over the conditions of interest. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Constant-depth, double-degree of freedom and variable-depth, multi-degree of freedom designs are carried through design, fabrication, and testing to validate the efficacy of the design process. Results illustrate the value of the design process in concurrently evaluating the relative costs/benefits of these liner designs. This study also provides an application for demonstrating the integrated use of duct acoustic propagation/radiation and liner modeling tools in the design and evaluation of novel broadband liner concepts for complex engine configurations.

  18. Use of x-ray radiographic methods in the study of clay liners

    International Nuclear Information System (INIS)

    Malone, P.G.; May, J.H.; Brown, K.W.; Thomas, J.C.

    1986-01-01

    X-ray radiography has been widely used in soil investigation to study the distribution of layers in soil cores and the effects of changing conditions (loading or impact) on soil structure. X-ray radiographic techniques also can be useful in studying clays or clay soils used in liners. Laboratory investigations were undertaken to demonstrate that X-ray radiographic techniques could be used to detect density and soil structure changes that usually accompany variations in hydraulic conductivity of clay liners. An example of a real-time test of a simulated bentonite and sand, liner attacked with acid lead nitrate and examples of radiographic examination of clay soil (non-calcareous smectite) samples that have been permeated by lead acetate or lead nitrate are presented. The changes in density and structure can be related to changes observed in hydraulic conductivity during permeation. X-ray radiography easily can be applied to field samples of soil or clay liner materials to detect density and structural changes that occur as the liner and permeating fluid interact. X-ray techniques have applications in both understanding failure mechanisms and forecasting liner performance

  19. Method of Retention Control for Compromised Periodontal Bone Support Abutment of Conical Crown Retained Denture

    Directory of Open Access Journals (Sweden)

    Chau-Hsiang Wang

    2010-08-01

    Full Text Available Conical crown-retained dentures (CCRD show a higher survival rate and greater patient satisfaction than transitional removable partial dentures during long-term follow-up. However, unsustainable denture retention force on supporting abutments after initial delivery and loss retention are frequently seen in long-term follow-up of clinical cases. The main causes are insufficient information concerning denture retention designs and the retention-tolerance of the supporting abutments. Monitoring by dental technicians of the quality of dental prostheses is critical. This case report describes an optimal method for CCRD construction that determines and distributes an optimal denture retention force on the supporting abutments to allow the patient to easily remove the denture while ensuring that the CCRD remains in place during physiologic activities. Oral rehabilitation with CCRD should consider the condition of the abutment periodontal support, the interarch occlusal relationship, supplemental fatigue of the terminal abutment, and patient's estimated bite force. The effects of friction on the abutment's inner crown were based on an optimal a angle. The dental laboratory used these measurements to fabricate a CCRD using a Koni-Meter to adjust the retention of the inner crown. This method protects the abutments and reduces the wear between the inner and outer crowns. The CCRD achieved good esthetic results and physiologic functions. Periodic long-term follow-up of the patient and CCRD after initial placement is recommended.

  20. Writing and Music: Album Liner Notes

    Directory of Open Access Journals (Sweden)

    Dean Leonard Biron

    2011-09-01

    Full Text Available A deceptive aspect of the ‘writing about music is like dancing about architecture’ cliché is the function of the preposition ‘about’. Literature and music, dance and architecture, painting and film – all are discrete aesthetic forms that nonetheless simultaneously feed off and provide nourishment for each other as part of art’s perpetual drive toward diversity and innovation. Nowhere is the aptness of the association between writing and music more obvious than in the phenomenon of album liner notes. Rather than merely an attempt at describing or translating musical experience, liner notes contribute to the dialogue between composer and listener and are a significant part of the culture of contemporary music.

  1. Effect of liner non-uniformity on plasma instabilities in an inverse Z-pinch magnetized target fusion system: liner-on-plasma simulations and comparison with linear stability analysis

    International Nuclear Information System (INIS)

    Subhash, P V; Madhavan, S; Chaturvedi, S

    2008-01-01

    Two-dimensional (2D) magneto-hydrodynamic (MHD) liner-on-plasma computations have been performed to study the growth of instabilities in a magnetized target fusion system involving the cylindrical compression of an inverse Z-pinch target plasma by a metallic liner. The growth of modes in the plasma can be divided into two phases. During the first phase, the plasma continues to be Kadomtsev stable. The dominant mode in the liner instability is imposed upon the plasma in the form of a growing perturbation. This mode further transfers part of its energy to its harmonics. During the second phase, however, non-uniform implosion of the liner leads to axial variations in plasma quantities near the liner-plasma interface, such that certain regions of the plasma locally violate the Kadomtsev criteria. Further growth ofthe plasma modes is then due to plasma instability. The above numerical study has been complemented with a linear stability analysis for the plasma, the boundary conditions for this analysis being obtained from the liner-on-plasma simulation. The stability of axisymmetric modes in the first phase is found to satisfy the Kadomtsev condition Q 0 1 modes, using equilibrium profiles from the 2D MHD study, shows that their growth rates can exceed those for m=0 by as much as an order of magnitude

  2. Applied algorithm in the liner inspection of solid rocket motors

    Science.gov (United States)

    Hoffmann, Luiz Felipe Simões; Bizarria, Francisco Carlos Parquet; Bizarria, José Walter Parquet

    2018-03-01

    In rocket motors, the bonding between the solid propellant and thermal insulation is accomplished by a thin adhesive layer, known as liner. The liner application method involves a complex sequence of tasks, which includes in its final stage, the surface integrity inspection. Nowadays in Brazil, an expert carries out a thorough visual inspection to detect defects on the liner surface that may compromise the propellant interface bonding. Therefore, this paper proposes an algorithm that uses the photometric stereo technique and the K-nearest neighbor (KNN) classifier to assist the expert in the surface inspection. Photometric stereo allows the surface information recovery of the test images, while the KNN method enables image pixels classification into two classes: non-defect and defect. Tests performed on a computer vision based prototype validate the algorithm. The positive results suggest that the algorithm is feasible and when implemented in a real scenario, will be able to help the expert in detecting defective areas on the liner surface.

  3. Effect of radiation losses on the compression of hydrogen by imploding solid liners

    International Nuclear Information System (INIS)

    Hussey, T.W.; Kiuttu, G.F.; Degnan, J.H.; Peterkin, R.E.; Smith, G.A.; Turchi, P.J.

    1996-01-01

    Quasispherical solid liner implosions with little or no instability growth have been achieved experimentally. Applications for such implosions include the uniform, shock-free compression of some sort of on-axis target. One proposed means of obtaining such compression is to inject a 1 eV hydrogen plasma working fluid between the liner and the target, and imploding the liner around it. the high initial temperature assures that the sound speed within the liner is always greater than the inner surface implosion velocity of the liner, and the initial density is chosen so that the volume of the working fluid at peak compression is sufficiently large so that perfectly spherical convergence of the liner is not required. One concern with such an approach is that energy losses associated with ionization and radiation will degrade the effective gamma of the compression. To isolate and, therefore, understand these effects the authors have developed a simple zero-dimensional model for the liner implosion that accurately accounts for the shape and thickness of the liner as it implodes and compresses the working fluid. Based on simple considerations they make a crude estimate of the range of initial densities of interest for this technique. They then observe that within this density rage, for the temperatures of interest, the lines are strongly self-absorbed so that the transport of radiation is dominated by bound-free and free-free processes

  4. The Logistical Challenges of the SpaceLiner Concept

    OpenAIRE

    van Foreest, Arnold; Sippel, Martin

    2008-01-01

    The SpaceLiner concept developed at DLR combines extremely fast transport (90 minutes from Europe to Australia) with the experience of Space flight. As such it is different from the spaceflight which focuses exclusively on space tourism but it combines space tourism with for example business travel. The SpaceLiner is designed to carry 50 passengers in suborbital flight. The conceptual technical design presents some challenges which have already been partially investigated at DLR [1]. However,...

  5. Comparison Predominant Oral micro-flora in Subjects with and without Complete Denture Referred to Yazd Dentistry Department

    Directory of Open Access Journals (Sweden)

    Abbas Ali Jafari

    2014-11-01

    Results: The non-aureus staphylococcus and alpha-hemolytic streptococci showed the highest positive culture among the isolated microorganisms in both groups, whereas beta hemolytic streptococci showed the least percent of isolated microorganism in both groups. The higher density of non-aureus Staphylococci, α-hemolitic Streptococci, Gram negative cocobasillus, non-pathogenic Neisseria, Candida and Corynebacterium were recovered from oral samples of denture users in compare with dentate subjects (P= 0.0001. There was also seen a statistical significant correlation between the number of isolated microorganisms and the duration of denture utilization in denture users (P=0.013. Conclusion: Results of the present study showed that complete denture can be act as a predisposal factor in overgrowing of several oral micro-flora particularly Candida, non-aureus Staphylococci, α-hemolytic streptococci, gram negative cocobacillus, non-pathogenic Neisseria, and Corynebacterium, which emphasized the users denture hygine.

  6. Effects of tacky mat contamination on bond degradation for Chemlok/liner and NBR/liner bonds

    Science.gov (United States)

    Padilla, A. M.

    1989-01-01

    Tacky mats are placed by the rubber lay-up areas for the solid rocket motor segments. These mats dust off the shoes prior to entering the platform where the lay-up work is performed. The possibility exists that a tacky mat could be touched with gloved hands prior to handling the uncured nitride butadiene rubber (NBR). Tests were run to determine if NBR were accidentally touched would there be any degradation of the liner/NBR bond. The tacky mats were judged solely on the basis of bond degradation caused by either direct or indirect contamination. Test results all indicate that there was no notable NBR/Chemlok or liner/NBR bond degradation on samples that came into contact with the tacky mat material. Testing procedures are described. The tacky mat adhesive composition does not contain fluorocarbons or release agents that would affect bonding.

  7. OVERLAY DENTURES: A REVIEW AND REPORT OF FOUR CASES

    Directory of Open Access Journals (Sweden)

    Deeksha SHARMA

    2013-12-01

    Full Text Available Patients with ectodermal dysplasia or having under‑ gone cleft surgery with anodontia or hypodontia, hypo‑ plastic conical teeth and patients with severely worn dentition are difficult to treat because of the poor remaining tooth structure. These patients often exhibit loss of vertical dimension of occlusion and aesthetic problems and usually need complex prosthetic treatments. Financial constraints or other priorities often restrict one from choosing the most desirable treatment. The overlay removable denture is a covering prosthesis partially supported by natural teeth, tooth roots, or dental implants, providing an efficient alter‑ native of treatment. Clinical reports describe the various applications of overlay dentures.

  8. Rehabilitation of underwater pipeline with liner; Reabilitacao de aqueduto submarino com liner: multiplas vantagens e aplicacoes

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Roberto S.; Oliveira, Jose N. de; Urtiga, Rogerio L.; Witt, R. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The system of water injection in XAREU oil production field has an water pipeline sizing 4'' of diameter, between the offshore platform PXA-1 and another PXA-2, that it transfers 165 m{sup 3}/d of salt water for pressurization of the reservoir through the injection well Xareu-23. This water pipeline always presented high degree of corrosion needing frequently installation of cramps to eliminate leakages. After evaluating the costs we conclude that the more attractive it would be the installation of a liner than the launching of a new water pipeline. For the installation of a new water pipeline we would need the approval of IBAMA and of a great number of resources for the substitution of that pipeline. In spite of treating of an unpublished service between two offshore platforms we chose for the installation of a liner, because we had a great technological domain in this service in onshore oil production facilities with many pipelines recovered with this technique. We had to revise all of the procedures so that there was not any surprise to make unfeasible this service. The installation of the system liner, consisted of an internal coating 'in situ' through the insert of plastic tubes(high density polyethylene-HDPE), that it forms a barrier between the pipeline and the transported fluid. (author)

  9. Fabrication of titanium alloy frameworks for complete dentures by selective laser melting.

    Science.gov (United States)

    Kanazawa, Manabu; Iwaki, Maiko; Minakuchi, Shunsuke; Nomura, Naoyuki

    2014-12-01

    Casting difficulties have led to the limited use of titanium in dental prostheses. The selective laser melting system was recently developed to fabricate biomedical components from titanium alloys. However, the fabrication of a titanium alloy framework for a maxillary complete denture by selective laser melting has not yet been investigated. The purpose of the study was to fabricate thin titanium alloy frameworks for a maxillary complete denture with a selective laser melting system and to evaluate their hardness and microstructure. A cast of an edentulous maxilla was scanned with a dental 3-dimensional cone-beam computed tomography system, and standard triangulation language data were produced with the DICOM Viewer (Digital Imaging and Communications in Medicine). Two types of metal frameworks for complete dentures were designed with 3-dimensional computer-aided design software. Two titanium alloy frameworks, SLM-1 and SLM-2, were fabricated from these designs with the selective laser melting system. Plate-shaped specimens were cut from the central flat region of SLM-1, SLM-2, and as-cast Ti-6Al-4V (As-cast). Vickers hardness testing, optical microscopy, and x-ray diffraction measurements were performed. Thin titanium alloy frameworks for maxillary complete dentures could be fabricated by selective laser melting. The hardness values for SLM-1 and SLM-2 were higher than that for the as-cast specimen. Optical microscopy images of the SLM-1 and SLM-2 microstructure showed that the specimens did not exhibit pores, indicating that dense frameworks were successfully obtained with the selective laser melting process. In the x-ray diffraction patterns, only peaks associated with the α phase were observed for SLM-1 and SLM-2. In addition, the lattice parameters for SLM-1 and SLM-2 were slightly larger than those for the as-cast specimen. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures

  10. Development of imploding liners with kinetic energies > 100 MJ and their applications

    International Nuclear Information System (INIS)

    Reinovsky, R.E.; Ekdahl, C.A.

    1996-01-01

    The Los Alamos program in High Energy Density Physics is developing high performance imploding liners as sources of high energy density environments for experimental physics applications. High performance liners are, for these purposes, liners with high velocity, 100 MJ or more kinetic energy at 20-50 MJ/cm of height. They must have sufficient azimuthal symmetry, axial uniformity and density to perform as high quality impactors on central, cylindrical targets. Scientific applications of such liners are numerous and varied. For example, the properties of materials at extreme energy densities can be assessed in such an experimental environment. The physics of plasmas near solid density can be studied and hydrodynamics experiments at high Mach number (above 5?) in materials that are near solid density and significantly ionized can be conducted. In addition, liners with substantial kinetic energy and good integrity at velocities of one to a few cm/microsec make good implosion drivers for fusion plasmas in the context of magnetized target fusion and MAGO

  11. Design, engineering and evaluation of refractory liners for slagging gasifiers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    deTineo, B J; Booth, G; Firestone, R F; Greaves, M J; Hales, C; Lamoureux, J P; Ledford, R R

    1982-08-01

    The contract for this program was awarded at the end of September 1978. Work was started on 1 October 1978, on Tasks A, B, and E. Task A, Conceptual Liner Designs, and Task B, Test System Design and Construction, were completed. Task C, Liner Tests, and Task D, Liner Design Evaluation, were to begin upon completion of Task B. Task E, Liner Model Development, is inactive after an initial data compilation and theoretical model development effort. It was to be activated as soon as data were available from Task D. Task F, Liner Design Handbook, was active along with Task A since the reports of both tasks were to use the same format. At this time, Tasks C, D, and F are not to be completed since funding of this project was phased out by DOE directive. The refractory text facility, which was constructed, was tested and found to perform satisfactorily. It is described in detail, including a hazard analysis which was performed. (LTN)

  12. Risk assessment for the transportation of radioactive zeolite liners

    International Nuclear Information System (INIS)

    1982-01-01

    The risk is estimated for the shipment of radioactive zeolite liners in support of the Zeolite Vitrification Demonstration Program currently underway at Pacific Northwest Laboratory under the sponsorship of the US Department of Energy. This program will establish the feasibility of zeolite vitrification as an effective means of immobilizing high-specific-activity wastes. In this risk assessment, it is assumed that two zeolite liners, each loaded around July 1, 1981 to 60,000 Ci, will be shipped by truck around January 1, 1982. However, to provide a measure of conservatism, each liner is assumed to initially hole 70,000 Ci, with the major radioisotopes as follow: 90 Sr = 3000 Ci, 134 Cs = 7000 Ci, 137 Cs = 60,000 Ci. Should shipment take place with essentially no delay after initial loading (regardless of loading date), the shipment loading would be only 2.7% higher than that for the assumed six-month delay. This would negligibly affect the overall risk. As a result of this risk assessment, it is concluded that the transport of the radioactive zeolite liners from TMI to PNL by truck can be conducted at an insignificant level of risk to the public

  13. Analysis of the effects of removable dentures on the psychological status, quality of life, and masticatory function of the elderly

    Science.gov (United States)

    Dyas, R.; Nathanael, M.; Indrasari, M.; Masulili, C.; Rahardjo, T. B.; Agustin, D.; Hogervorst, E.; Kusdhany, L.

    2017-08-01

    Older age is a major risk factor for diseases of the teeth and mouth and dementia. Diseases of the teeth and mouth can lead to tooth loss. The use of removable dentures can help the elderly to replace lost teeth; therefore, dentures are expected to improve the masticatory function, quality of life, and psychological status of the elderly. The aim of this study was to analyze the effects of removable denture usage on the improvement of the psychological status, quality of life, and masticatory function of elderly people. The data was obtained from 30 respondents. The patients answered questionnaires before they used the dentures, 2 weeks after they began using dentures, and 2 months after they started wearing dentures. Four different questionnaires were used: EuroQol Five Dimensions questionnaire (EQ-5D) and Geriatric Depression Scale (GDS), to measure psychological status; a mastication questionnaire to measure masticatory function; and a validated quality of life questionnaire. Based on the results of this study, it is clear that after 2 months of denture usage, removable dentures in the elderly can significantly improve their quality of life, masticatory function, and psychological status(p<0.05).

  14. The effect of surface roughness on the performances of liner-piston ...

    African Journals Online (AJOL)

    The effect of surface roughness on the performances of liner-piston ring contact in internal combustion engine. ... The surface roughness between the liner and the piston rings, plays an ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    Science.gov (United States)

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of

  16. Sodium leak and combustion experiment-II report. Evaluation result of damage of mild steel liner

    Energy Technology Data Exchange (ETDEWEB)

    Aoto, K.; Hirakawa, Y.; Kuroda, T. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1996-09-01

    Several material analyses on damage of the floor liner made of a mild steel which was in the test cell of the second sodium leak and combustion experiment (Test-2) performed in OEC/PNC on June 7 in 1996 were carried out to clarify the following issues. (1) Difference of the corrosion mechanism of Test-2 liner to that of the first sodium leak and combustion experiment (Test-1) liner. (2) The vital factor which can desides corrosion mechanism and damage location. The following analyses were accomplished. (1) Microstructure observation, (2) EPMA for cross-section of vicinity of corroded area, (3) X-ray diffraction (XRD) for the interface between corrosion product-liner (mild steel). The differences between the corrosion mechanism of Test-1 liner which is seemed to be the same that of `MONJU` liner and that of Test-2 liner is discussed based on the results of these material analyses. As the result, the Na-Fe double oxidization with mechanical/chemical removal of reaction product can be occurred on the Test-1 and `MONJU` liner. On the other hand, a hot-corrosion, that is the molten salt type corrosion is subject to be thinning of the Test-2 liner. All failures of Test-2 liner surround at the halfway up a convex. Considering the above corrosion mechanism, that fact leads that significant damage is occurred at the molten salt level. (author)

  17. Rresence of different Candida species at denture wearers with type 2 diabetes and clinically healthy oral mucosa: Pilot study

    OpenAIRE

    Matić-Petrović, Sanja; Barać, Milena; Kuzmanović-Pfićer, Jovana; Radunović, Milena; Jotić, Aleksandra; Pucar, Ana

    2018-01-01

    Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS) and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental...

  18. A new approach to the design of LMFBR liners

    International Nuclear Information System (INIS)

    Polentz, L.M.

    1980-01-01

    An advance in the state-of-the-art of LMFBR liners which permits notable savings in construction costs without any sacrifice of safety is described. The application of the new design concept to the rework of the upper reactor vault liner of the FFTF is discussed. Factors which affect the application of the new design approach to other LMFBRs are delineated and discussed. (author)

  19. Effect of long-term water immersion or thermal shock on mechanical properties of high-impact acrylic denture base resins.

    Science.gov (United States)

    Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro

    2016-01-01

    The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.

  20. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  1. Thoracoscopic retrieval of a "smiling" foreign body from the proximal esophagus: an impacted denture.

    Science.gov (United States)

    Palanivelu, Chinnusamy; Rangarajan, Muthukumaran; Parthasarathi, Ramakrishnan; Senthilnathan, Palaniswamy

    2008-06-01

    The esophagus is a common site for foreign bodies (FBs) because of areas of physiologic narrowing. Dentures pose special problems, especially if they are impacted. We present a case of a "smiling" foreign body in the proximal esophagus. The patient was an 80-year-old man with a history of dysphagia and swallowed dentures. Thoracoscopic removal was performed successfully as an endoscopic removal had failed and the patient had an uneventful postoperative recovery. He was discharged on the seventh postoperative day. Coins are the most commonly ingested FBs. Swallowing of dentures is found mostly in elderly patients. If endoscopic removal is not possible, then a minimally invasive surgery is an alternative. Swallowing of dentures is rare, and its thoracoscopic removal has not been reported so far. Using thoracoscopy, all the benefits of a minimally invasive surgery can be used. Minimally invasive techniques have been found to be very useful in the removal of intraluminal FBs, especially when conservative measures fail. Prevention of such incidents should be emphasized.

  2. Comparison of recognition about denture adhesive between Japanese and Indonesian dentists: A pilot study

    Directory of Open Access Journals (Sweden)

    Shinsuke Sadamori

    2005-12-01

    Full Text Available The purpose of this study was to compare cross-national differences of the recognition of denture adhesive among dentists. The design of the research was cross-cultural differences. The research was done in Japan and Indonesia. One hundred and ten dentists from Japan and Indonesia were surveyed using a questionnaire regarding knowledge/comprehension of denture adhesive (in Japanese and Indonesian versions respectively. Logistic regression model (forward stepwise method showed that it was possible to distinguish Japanese dentists from Indonesian peers with a probability of 96.0 per cent by using 4 items out of 16. For the question of "How many domestic products of denture adhesive (DA do you know?" approximately a half of the Japanese dentists answered "less than 3", whereas 93 per cent of Indonesian subjects answered "nothing". It was concluded that there were much differences in dentists' understanding and experience of denture adhesive in the clinic, between Japan and Indonesia.

  3. Formation of imploding plasma liners for fundamental HEDP studies and MIF Standoff Driver Concept

    Energy Technology Data Exchange (ETDEWEB)

    Cassibry, Jason [Univ. of AL in Huntsville; Hatcher, Richard [Univ. of AL in Huntsville; Stanic, Milos [Univ. of AL in Huntsville

    2013-08-17

    The disciplines of High Energy Density Physics (HEDP) and Inertial Confinement Fusion (ICF) are characterized by hypervelocity implosions and strong shocks. The Plasma Liner Experiment (PLX) is focused on reaching HEDP and/or ICF relevant regimes in excess of 1 Mbar peak pressure by the merging and implosion of discrete plasma jets, as a potentially efficient path towards these extreme conditions in a laboratory. In this work we have presented the first 3D simulations of plasma liner, formation, and implosion by the merging of discrete plasma jets in which ionization, thermal conduction, and radiation are all included in the physics model. The study was conducted by utilizing a smoothed particle hydrodynamics code (SPHC) and was a part of the plasma liner experiment (PLX). The salient physics processes of liner formation and implosion are studied, namely vacuum propagation of plasma jets, merging of the jets (liner forming), implosion (liner collapsing), stagnation (peak pressure), and expansion (rarefaction wave disassembling the target). Radiative transport was found to significantly reduce the temperature of the liner during implosion, thus reducing the thermal leaving more pronounced gradients in the plasma liner during the implosion compared with ideal hydrodynamic simulations. These pronounced gradients lead to a greater sensitivity of initial jet geometry and symmetry on peak pressures obtained. Accounting for ionization and transport, many cases gave higher peak pressures than the ideal hydrodynamic simulations. Scaling laws were developed accordingly, creating a non-dimensional parameter space in which performance of an imploding plasma jet liner can be estimated. It is shown that HEDP regimes could be reached with ~ 5 MJ of liner energy, which would translate to roughly 10 to 20 MJ of stored (capacitor) energy. This is a potentially significant improvement over the currently available means via ICF of achieving HEDP and nuclear fusion relevant parameters.

  4. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    Science.gov (United States)

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages

  5. Acoustic Liner Drag: Measurements on Novel Facesheet Perforate Geometries

    Science.gov (United States)

    Howerton, Brian M.; Jones, Michael G.

    2016-01-01

    Interest in characterization of the aerodynamic drag of acoustic liners has increased in the past several years. This paper details experiments in the NASA Langley Grazing Flow Impedance Tube to quantify the relative drag of several perforate-over-honeycomb liner configurations at flow speeds of centerline flow Mach number equals 0.3 and 0.5. Various perforate geometries and orientations are investigated to determine their resistance factors using a static pressure drop approach. Comparison of these resistance factors gives a relative measurement of liner drag. For these same flow conditions, acoustic measurements are performed with tonal excitation from 400 to 3000 hertz at source sound pressure levels of 140 and 150 decibels. Educed impedance and attenuation spectra are used to determine the impact of variations in perforate geometry on acoustic performance.

  6. Daya Hambat Infusum Daun Sirih Terhadap Pertumbuhan Staphylococcus aureus Yang Diisolasi Dari Denture Stomatitis ; Penelitian In Vitro.

    OpenAIRE

    bin Abdullah, Muhammad Naim

    2011-01-01

    Denture Stomatitis merupakan lesi mukosa oral berwarna merah, sakit, dan bengkak, kondisi ini karena kebiasaan jelek pada pemakai gigitiruan yang tidak mumbuka protesa pada malam hari dan jarang dibersihkan. Faktor sistemik yang mendukung terjadinya Denture Stomatitis dapat disebabkan oleh beberapa bakteri, salah satunya Staphylococcus aureus. Pencegahan Denture Stomatitis dapat dilakukan dengan sering membersihkan gigitiruan dan pemakaian obat kumur. Tujuan penelitian ini adalah untuk menguj...

  7. Field performance assessment of synthetic liners for uranium tailings ponds: a status report

    International Nuclear Information System (INIS)

    Mitchell, D.H.; Spanner, G.E.

    1984-03-01

    The objective of this study is to provide a database to support US Nuclear Regulatory Commission (NRC) licensing of uranium tailings leachate isolation impoundments. This objective is being accomplished by determining the effectiveness of design, installation, and quality assurance practices associated with uranium mill tailings impoundments with flexible membrane liners. The program includes testing of chemical resistance and physical performance of liners, leak detection systems, and seam inspection techniques. This report presents the status of the program through September 1983. The report addresses impoundment design, installation, and inspection techniques used by the uranium milling industry. To determine the relative successes of these techniques, information has been collected from consultants, mill operators, and the synthetic liner industry. Progress in experimental tasks on chemical resistance of liners, physical properties of liners, and nondestructive examination of seams is reported. 25 references, 9 figures, 13 tables

  8. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  9. Some features of liners convergence accelerated with the help of powerful EMGs

    Energy Technology Data Exchange (ETDEWEB)

    Grinevich, B E; Chernyshev, V K; Buzin, V N; Petrukhin, A A; Zarionov, E I [All-Russian Science and Research Institute of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Described are experiments devoted to the convergence of condensed liners, non-exploding during the flight, under the influence of current. To feed the liners with a power of not less than 25 MJ, powerful explosive magnetic 1000 mm diameter generators were used. Interesting effects arising during the liners flight were observed. A comparison of experimental results and calculations carried out using the SMOG program, showed that the calculated current was 20% higher than the observed current. At the same time, the experimental speed exceeded the rated speed calculated according to the known current curve. The asymmetry of current distribution along the liners was defined depending on time. Some conclusions concerning the current spread symmetry are made. (author). 4 figs., 1 ref.

  10. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  11. Radiation therapy of the oral cavity: sequelae and management, part 2

    International Nuclear Information System (INIS)

    Beumer, J.; Curtis, T.; Harrison, R.E.

    1979-01-01

    This is the concluding portion of a two-part series dealing with the effects and manifestations in the oral cavity of radiation therapy of head and neck tumors. Preradiation and postradiation extractions in dentulous patients, as well as dental maintenance of such patients (including fluoride treatments follow-up, and restorative care), are discussed. Guidelines for the dental management of edentulous patients are also presented at length (this section covers risk of bone necrosis, soft liners, timing of denture placement, dentures and preexisting bone necrosis, soft-tissue necrosis and dentures, morbidity, and prosthodontic procedures). The article concludes with a brief discussion of osteoradionecrosis and soft-tissue necrosis

  12. Critical interfaces in geosynthetic multilayer liner system of a landfill

    Directory of Open Access Journals (Sweden)

    Qian Xuede

    2008-12-01

    Full Text Available This study is to identify the critical interface in a geosynthetic multilayer liner system by examining the effects of the interface shear strength of liner components, leachate level, leachate buildup cases, and peak and residual interface strengths. According to current landfill design procedures, conducting stability analysis along the same interface at both the back slope and base may result in a non-conservative result. The critical interfaces with the minimum factor of safety are generally found at different locations along the back slope and base. The critical interface for a multilayer liner system cannot simply be assumed during stability analysis. It can shift from one interface to another with changes in the leachate level and with different leachate buildup cases. The factor of safety for an interface with a high friction angle and low apparent cohesion generally drops much more quickly than it does under inverse conditions when the leachate level increases. The failure interface in a liner system under residual conditions is usually different from the failure interface under peak conditions.

  13. Engineering design of the LINUS-O prototype liner implosion system

    International Nuclear Information System (INIS)

    Turchi, P.J.; Jenkins, D.J.; Warnick, W.L.; Ford, R.D.; Lanham, R.; Cooper, A.L.; Burton, R.L.

    1977-01-01

    The development of imploding liner flux compression techniques for application to compact, pulsed fusion reactors has led to the concept of rotating liquid metal implosions driven by free-pistons. In hydrodynamic model tests, such implosions have been demonstrated to be stable and reversible, allowing serious consideration of a new class of pulsed fusion reactor. The next step is to demonstrate repetitive, controlled operation at high energy densities with liquid metal liners, for which peak magnetic field levels approaching a megagauss are possible. A prototype controlled liner implosion system, LINUS-O, has been designed and is under construction. During operation, the annular driving-piston surrounding the implosion chamber is displaced axially by the action of pulsed high pressure gas at several hundred atmospheres. The piston and chamber rotate at 2100 RPM, allowing the free inside surface of the liner to implode stably from 30 cm diameter to 1.0 cm at turnaround. The experimental facility is described and engineering problems associated with design and operation of controlled high energy implosion systems are discussed

  14. Design of the ZTH vacuum liner

    International Nuclear Information System (INIS)

    Prince, P.P.; Dike, R.S.

    1987-01-01

    The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to complete the torus. The thin bellows sections maximize the liner toroidal resistance and the ribs provide support and positional accuracy for the armour in relation to the conducting shell. Heat transfer from the vessel is controlled by a blanket wrap of ceramic fiber insulation and the heat flux is dissipated to a water cooling jacket in the conducting shell

  15. Evaluation of the Periodontal Status of Abutment Teeth in Removable Partial Dentures.

    Science.gov (United States)

    Correia, André Ricardo Maia; da Silva Lobo, Fábio Daniel; Miranda, Mónica Célia Pereira; Framegas de Araújo, Filipe Miguel Soares; Santos Marques, Tiago Miguel

    2017-12-15

    The purpose of this study was to evaluate whether the use of removable partial dentures affects the periodontal status of abutment teeth. An observational cross-sectional study was done on a sample of patients rehabilitated with removable partial dentures (2010 to 2013). At a recall appointment, a clinical examination was done to collect data related to the rehabilitation and periodontal status of the abutment teeth. Of 145 invited patients, 54 attended the requested follow-up appointment (37.2%). Mean patient age was 59.1 years, and the study population was 42.6% male and 57.4% female. The mean follow-up time for the prosthesis was 26 months. Abutment teeth had higher values in all periodontal variables (P removable partial dentures is affected by these rehabilitations. A recall program for these patients involving removable prosthodontics and periodontology appointments is mandatory.

  16. Experimental plans for LMFBR cavity liner sodium spill test LT-1

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Newell, G.A.

    1976-01-01

    Reinforced concrete is an important material of construction in LMFBR cavities and cells. Steel liners are often installed on the concrete surfaces to provide a gastight seal for minimizing air inleakage to inerted cell atmospheres and to protect the concrete from direct contact with sodium in the event of a sodium spill. In making safety assessment analyses, it is of interest to determine the adequacy of the liners to maintain their leaktightness during postulated accidents involving large sodium spills. However, data for basing analytical assessments of cell liners are very meager and an experimental program is underway at HEDL to provide some of the needed information. The HEDL cell liner evaluation program consists of both bench-scale feature tests and large-scale sodium spill demonstration tests. The plans for the first large-scale sodium spill test (LT-1) are the subject of this paper

  17. Overdenture retained by teeth using a definitive denture base technique: a case report.

    Science.gov (United States)

    Nascimento, D F F; dos Santos, J F F; Marchini, L

    2010-09-01

    This paper presents a technique involving the use of a definitive denture base to make overdentures. Cores with ball attachments were cemented over remaining lower teeth. Impressions of the edentulous maxilla and mandible were taken to obtain a definitive acrylic resin base. The definitive base of the mandible was perforated at the location of ball attachments and its female components were fixed to the base using acrylic resin directly in the patient's mouth. Wax rims were then made, jaw relationships recorded, teeth mounted and tried in, and the dentures were cured. This technique allowed for easy fixing of female components and better retention during the recording of jaw relationships, and can also be used in the construction of implant retained dentures.

  18. Prevalence of signs and symptoms of temporomandibular disorders (TMD) in patients wearing bimaxillary complete dentures, removable partial dentures and in students with natural dentition.

    Science.gov (United States)

    Bordin, Thaisa B; Conci, Ricardo A; Pezzini, Maristela M G; Pezzini, Rolando P; Mendonça, Márcio J

    2013-01-01

    Temporomandibular Disorder (TMD) has attained a prominent role within the context of dental care due to its high prevalence. The aim of this study was to evaluate the prevalence of signs and symptoms of TMD in students at the State University of West of Paraná (UNIOESTE) with natural dentition, and in patients with removable partial dentures and double complete dentures. A total of 210 randomly selected individuals of both genders were evaluated, being divided into three groups: seventy students at the UNIOESTE with natural dentition (Group 1), seventy patients with removable partial dentures (Group 2) and seventy patients with bimaxillary complete dentures (Group 3). The data were collected by a single examiner using the American Academy of Orofacial Pain questionnaire for triage, where a single affirmative response to any of the situations mentioned was enough to carry out clinical evaluation. Kolmogorov Smirnov, Mann Whitney, Chi-Square, ANOVA and Tukey's statistical tests were performed. The most prevalent signs and symptoms of TMD in Group 1 were pain or difficulty in chewing or talking, perception of recent change in bite and deviations during the course of mandibular movements. In Group 2 they were perceptions of recent changes in the bite, deflections in the mandibular movements, presence of joint sounds, pain during excursive movements and muscle tenderness. The most prevalent signs and symptoms in Group 3 were limited to mouth opening and poor stability and retention of at least one of the prostheses. Group 3 also reported having received treatment for headaches or facial pain with a high prevalence. Group 2 had the highest prevalence of signs and symptoms. Prevalence was similar in Groups 1 and 3.

  19. Presence of Different Candida Species at Denture Wearers With Type 2 Diabetes and Clinically Healthy Oral Mucosa-Pilot Study

    Directory of Open Access Journals (Sweden)

    Petrović Sanja Matić

    2018-03-01

    Full Text Available Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental groups: systematically health subjects; patients with diagnosed Type 2 Diabetes (T2D and good glycoregulation; and T2D subjects with poorly regulated blood sugar level. Cotton swab samples were obtained from each patient from hard palate mucosa and denture surface. Swab cultures were made on Sabouraud dextrose agar and ChromAgar Media for distinciton of various Candida spp. Density growth was also measured. Results: Frequency of Candida spp. findings were similar between groups. At healthy subjects, only C.albicans was detected. At diabetics, C.albicans was the most common isolated species, followed by C.glabrata and C.tropicalis. Negative finding of yeasts on palatal mucosa, but positive on denture surface were detected at all groups, with the highest frequency (33.4% at diabetics with poor glycoregulation. Denture surface was heavier colonized than hard palate mucosa. Duration of diabetes in years were only independent predictors for harboring Candida spp. at denture surface (Exp B=1.186, CI=1.047-1.344, p=0.007. Conclusions: Prosthesis of denture wearers without DS may serve as reservoir of Candida spp. Presence of more pathogenic and resistant non-albicans species are related to diabetics, even without clinical signs of DS.

  20. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    Science.gov (United States)

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  1. Effect of microwave postpolymerization treatment on residual monomer content and the flexural strength of autopolymerizing reline resin

    Directory of Open Access Journals (Sweden)

    Patil Padmakar

    2009-01-01

    Full Text Available Background : Microwave postpolymerization has been suggested as a method to improve the flexural strength of an autopolymerizing denture reline resin. However, the effect of microwave postpolymerization on the residual monomer content and its influence on flexural strength have not been investigated. Objectives : This study analyzed the effect of microwave postpolymerization on the residual monomer content and its influence on the flexural strength of an autopolymerizing reline resin (Denture Liner. Materials and Methods : A total of 70 specimens (64 Χ 10 Χ 3.3 mm were polymerized according to the manufacturer′s instructions and divided into 7 groups (n = 10. Control group specimens were not subjectedto any further processing. Before testing, the specimens were subjected to postpolymerization in a microwave oven using different power (550 and 650 W and time (3, 4, and 5 min settings. Two specimens of each group were then manually ground into fine powder and samples extracted from the specimens using reflux method. The samples were then subjected to gas chromatography for residual monomer determination in area%. Eight specimens were subjected to a three-point bending device with a span of 50 mm and crosshead speed of 5 mm/min, and the flexural strength was determined in MPa. Data analyses included Student′s t-test and one-way analysis of variance. Results : For the Denture Liner reline resin, the residual monomer content decreased and the flexural strength increased significantly with the application of microwave irradiation using different time/power combinations. The specimens with the lowest residual monomer content were the similar specimens which presented with the highest flexural strength. Conclusion : Microwave postpolymerization irradiation can be an effective method for increasing the flexural strength of denture liner (at 650 W for 5 min by reducing the residual monomer content by further polymerization at free radical sites.

  2. Inductively Driven, 3D Liner Compression of a Magnetized Plasma to Megabar Energy Densities

    Energy Technology Data Exchange (ETDEWEB)

    Slough, John [MSNW LLC, Redmond, WA (United States)

    2015-02-01

    To take advantage of the smaller scale, higher density regime of fusion an efficient method for achieving the compressional heating required to reach fusion gain conditions must be found. What is proposed is a more flexible metallic liner compression scheme that minimizes the kinetic energy required to reach fusion. It is believed that it is possible to accomplish this at sub-megajoule energies. This however will require operation at very small scale. To have a realistic hope of inexpensive, repetitive operation, it is essential to have the liner kinetic energy under a megajoule which allows for the survivability of the vacuum and power systems. At small scale the implosion speed must be reasonably fast to maintain the magnetized plasma (FRC) equilibrium during compression. For limited liner kinetic energy, it becomes clear that the thinnest liner imploded to the smallest radius consistent with the requirements for FRC equilibrium lifetime is desired. The proposed work is directed toward accomplishing this goal. Typically an axial (Z) current is employed for liner compression. There are however several advantages to using a θ-pinch coil. With the θ-pinch the liner currents are inductively driven which greatly simplifies the apparatus and vacuum system, and avoids difficulties with the post implosion vacuum integrity. With fractional flux leakage, the foil liner automatically provides for the seed axial compression field. To achieve it with optimal switching techniques, and at an accelerated pace however will require additional funding. This extra expense is well justified as the compression technique that will be enabled by this funding is unique in the ability to implode individual segments of the liner at different times. This is highly advantageous as the liner can be imploded in a manner that maximizes the energy transfer to the FRC. Production of shaped liner implosions for additional axial compression can thus be readily accomplished with the modified power

  3. Development of laser cutting method for stainless steel liner

    International Nuclear Information System (INIS)

    Ishihara, Satoshi; Takahata, Masato; Wignarajah, Sivakumaran; Kamata, Hirofumi

    2007-01-01

    The present work is an attempt to develop a laser cutting method for cutting and removing stainless steel liners from concrete walls and floors in nuclear facilities. The effect of basic laser cutting parameters such as energy, cutting speed, assist gas flow etc. were first studied through cutting experiments on mock-up concrete specimens lined with 3mm thick stainless steel sheets using a 1kW Nd:YAG laser. These initial studies were followed by further studies on the effect of unevenness of the liner surface and on a new method of confining contamination during the cutting process using a sliding evacuation hood attached to the laser cutting head. The results showed that laser cutting is superior to other conventional cutting methods from the point of view of safety from radioactivity and work efficiency when cutting contaminated stainless steel liners. (author)

  4. Repairing liner of the reactor

    International Nuclear Information System (INIS)

    Aguilar H, F.

    2001-07-01

    Due to the corrosion problems of the aluminum coating of the reactor pool, a periodic inspections program by ultrasound to evaluate the advance grade and the corrosion speed was settled down. This inspections have shown the necessity to repair some areas, in those that the slimming is significant, of not making it can arrive to the water escape of the reactor pool. The objective of the repair is to place patches of plates of 1/4 inch aluminum thickness in the areas of the reactor 'liner', in those that it has been detected by ultrasound a smaller thickness or similar to 3 mm. To carry out this the fuels are move (of the core and those that are decaying) to a temporary storage, the structure of the core is confined in a tank that this placed inside the pool of the reactor, a shield is placed in the thermal column and it is completely extracted the water for to leave uncover the 'liner' of the reactor. (Author)

  5. High Thermal Conductivity NARloy-Z-Diamond Composite Liner for Advanced Rocket Engines

    Science.gov (United States)

    Bhat, Biliyar; Greene, Sandra

    2015-01-01

    NARloy-Z (Cu-3Ag-0.5Zr) alloy is state-of-the-art combustion chamber liner material used in liquid propulsion engines such as the RS-68 and RS-25. The performance of future liquid propulsion systems can be improved significantly by increasing the heat transfer through the combustion chamber liner. Prior work1 done at NASA Marshall Space Flight Center (MSFC) has shown that the thermal conductivity of NARloy-Z alloy can be improved significantly by embedding high thermal conductivity diamond particles in the alloy matrix to form NARloy-Z-diamond composite (fig. 1). NARloy-Z-diamond composite containing 40vol% diamond showed 69% higher thermal conductivity than NARloy-Z. It is 24% lighter than NARloy-Z and hence the density normalized thermal conductivity is 120% better. These attributes will improve the performance and life of the advanced rocket engines significantly. The research work consists of (a) developing design properties (thermal and mechanical) of NARloy-Z-D composite, (b) fabrication of net shape subscale combustion chamber liner, and (c) hot-fire testing of the liner to test performance. Initially, NARloy-Z-D composite slabs were made using the Field Assisted Sintering Technology (FAST) for the purpose of determining design properties. In the next step, a cylindrical shape was fabricated to demonstrate feasibility (fig. 3). The liner consists of six cylinders which are sintered separately and then stacked and diffusion bonded to make the liner (fig. 4). The liner will be heat treated, finish-machined, and assembled into a combustion chamber and hot-fire tested in the MSFC test facility (TF 115) to determine perform.

  6. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  7. Fabrication Process for Machined and Shrink-Fitted Impactor-Type Liners for the LOS Alamos Hedp Program

    Science.gov (United States)

    Randolph, B.

    2004-11-01

    Composite liners have been fabricated for the Los Alamos liner-driven High Energy Density Physics (HEDP) experiments using impactors formed by physical vapor deposition, and by machining and shrink fitting. Chemical vapor deposition has been proposed for some ATLAS liner applications. This paper describes the processes used to fabricate machined and shrink-fitted impactors; these processes have been used for copper impactors in 1100 aluminum liners and for 6061 T-6 aluminum impactors in 1100 aluminum liners. The most successful processes have been largely empirically developed and rely upon a combination of shrink-fitting and light press fitting. The processes used to date will be described along with some considerations for future composite liners for the HEDP Program.

  8. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  9. Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

    Science.gov (United States)

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a "biometric quality" tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  10. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Bernhard Pommer

    2012-01-01

    Full Text Available The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  11. INVESTIGATION OF DENTURE REMOVAL PROCESS BY MEANS OF DESTRUCTION OF FIXING CEMENT BY ULTRASOUND ACTION

    Directory of Open Access Journals (Sweden)

    M. G. Kiselev

    2007-01-01

    Full Text Available The paper contains results of experimental investigations in respect of denture removal processes using as models so natural teeth as well and this removal process presupposes destruction of fixing cement by ultrasound action. It has been established that the best conditions for separation of a denture from a tooth body are ensured while ultrasound is acting on non-removable denture structure in liquid phase (water. At the expense of sound-capillary effect water fills in porous structure of fixing cement at high speed and a cavitation that appears in it leads to intensive cement destruction (dispersion.

  12. Skin-Inspired Hydrogel-Elastomer Composite with Application in a Moisture Permeable Prosthetic Limb Liner

    Science.gov (United States)

    Ruiz, Esteban

    Recent advances in fields such as 3D printing, and biomaterials, have enabled the development of a moisture permeable prosthetic liner. This project demonstrates the feasibility of the invention by addressing the three primary areas of risk including the mechanical strength, the permeability, and the ability to manufacture. The key enabling technology which allows the liner to operate is the skin inspired hydrogel elastomer composite. The skin inspiration is reflected in the molecular arrangement of the double network of polymers which mimics collagen-elastin toughening in the natural epidermis. A custom formulation for a novel tough double network nanocomposite reinforced hydrogel was developed to improve manufacturability of the liner. The liner features this double network nanocomposite reinforced hydrogel as a permeable membrane which is reinforced on either side by perforated silicone layers manufactured by 3d printing assisted casting. Uniaxial compression tests were conducted on the individual hydrogels, as well as a representative sample of off the shelf prosthetic liners for comparison. Permeability testing was also done on the same set of materials and compared to literature values for traditional hydrogels. This work led to the manufacture of three generations of liner prototypes, with the second and third liner prototype being tested with human participants.

  13. One-dimensional MHD simulations of MTF systems with compact toroid targets and spherical liners

    Science.gov (United States)

    Khalzov, Ivan; Zindler, Ryan; Barsky, Sandra; Delage, Michael; Laberge, Michel

    2017-10-01

    One-dimensional (1D) MHD code is developed in General Fusion (GF) for coupled plasma-liner simulations in magnetized target fusion (MTF) systems. The main goal of these simulations is to search for optimal parameters of MTF reactor, in which spherical liquid metal liner compresses compact toroid plasma. The code uses Lagrangian description for both liner and plasma. The liner is represented as a set of spherical shells with fixed masses while plasma is discretized as a set of nested tori with circular cross sections and fixed number of particles between them. All physical fields are 1D functions of either spherical (liner) or small toroidal (plasma) radius. Motion of liner and plasma shells is calculated self-consistently based on applied forces and equations of state. Magnetic field is determined by 1D profiles of poloidal and toroidal fluxes - they are advected with shells and diffuse according to local resistivity, this also accounts for flux leakage into the liner. Different plasma transport models are implemented, this allows for comparison with ongoing GF experiments. Fusion power calculation is included into the code. We performed a series of parameter scans in order to establish the underlying dependencies of the MTF system and find the optimal reactor design point.

  14. A competing risk model for the reliability of cylinder liners in marine Diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Bocchetti, D. [Grimaldi Group, Naples (Italy); Giorgio, M. [Department of Aerospace and Mechanical Engineering, Second University of Naples, Aversa (Italy); Guida, M. [Department of Information Engineering and Electrical Engineering, University of Salerno, Fisciano (Italy); Pulcini, G. [Istituto Motori, National Research Council-CNR, Naples (Italy)], E-mail: g.pulcini@im.cnr.it

    2009-08-15

    In this paper, a competing risk model is proposed to describe the reliability of the cylinder liners of a marine Diesel engine. Cylinder liners presents two dominant failure modes: wear degradation and thermal cracking. The wear process is described through a stochastic process, whereas the failure time due to the thermal cracking is described by the Weibull distribution. The use of the proposed model allows performing goodness-of-fit test and parameters estimation on the basis of both wear and failure data. Moreover, it enables reliability estimates of the state of the liners to be obtained and the hierarchy of the failure mechanisms to be determined for any given age and wear level of the liner. The model has been applied to a real data set: 33 cylinder liners of Sulzer RTA 58 engines, which equip twin ships of the Grimaldi Group. Estimates of the liner reliability and of other quantities of interest under the competing risk model are obtained, as well as the conditional failure probability and mean residual lifetime, given the survival age and the accumulated wear. Furthermore, the model has been used to estimate the probability that a liner fails due to one of the failure modes when both of these modes act.

  15. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    Science.gov (United States)

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  16. Clinical evaluation of the essential oil of "Satureja Hortensis" for the treatment of denture stomatitis

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Sabzghabaee

    2012-01-01

    Full Text Available Background: The prevalence of denture stomatitis has been shown to vary from 15 to 65% in complete denture wearers. Satureja hortensis L. has been considered to have antinociceptive, anti-inflammatory, antifungal and antimicrobial activities in vitro and exhibits strong inhibitory effect on the growth of periodontal bacteria. The aim of this study was to evaluate the efficacy of a 1% gel formulation of S. hortensis essential oil for the treatment of denture stomatitis. Materials and Methods: A randomized, controlled clinical trial study was conducted on 80 patients (mean age 62.91±7.34 in two parallel groups treated either with S. hortensis essential oil 1% gel or placebo applied two times daily for two weeks. Denture stomatitis was diagnosed by clinical examination and paraclinical confirmation with sampling the palatal mucosa for Candida albicans. Data were analyzed using Chi-squared or Student′s t tests. Results: The erythematous lesions of palatal area were significantly reduced (P<0.0001 in the treatment group who applied 1% topical gel of S. hortensis essential oil and Candida colonies count were reduced significantly (P=0.001. Conclusion: Topical application of the essential oil of S. hortensis could be considered as an effective agent for the treatment of denture stomatitis.

  17. [Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology].

    Science.gov (United States)

    Deng, K H; Wang, Y; Chen, H; Zhao, Y J; Zhou, Y S; Sun, Y C

    2017-06-09

    Objective: To quantitatively evaluate the adaptation of polylactic acid (PLA) pattern of mandibular complete denture fabricated by fused deposition modeling (FDM) technology. Methods: A mandibular complete denture digital model was designed through a complete denture design software based on a pair of standard maxillomandibular edentulous plaster model and their occlusion bases. Ten PLA mandibular complete dentures were printed with a FDM machine. The dentures were scanned with and without the plaster model using a three-dimensional (3D) scanner. In Geomagic software, the scanning data of printed dentures were registered to its computer aided design (CAD) data, and the printing error was analyzed using the multipoint registration command. For quantitatively evaluating the adaptation of the denture, the data of plaster model and PLA denture were registered to the whole data of denture located in the plaster model using the best-fit alignment command, the 3D deviation of the plaster model and tissue surface of the denture represent the space between them. The overall area was separated into three parts: primary stress-bearing area, secondary stress-bearing area and border seal area, and the average deviations of these three parts were measured. The values were analyzed using analysis of variance. Results: Compared with the CAD data, the printing error was (0.013±0.004) mm. The overall 3D deviation between PLA denture and plaster model was (0.164±0.033) mm, in which the primary stress-bearing area was (0.165± 0.045) mm, the secondary stress-bearing area was (0.153 ± 0.027) mm, the border seal area was (0.186 ± 0.043) mm. These showed a good fit in the majority parts of the FDM denture to the plaster model. No statistically significant difference was observed between the three areas ( F =1.857, P =0.175>0.05). Conclusions: Combined with the 3D scanning, CAD and FDM technology, a FDM 3D printing process of complete denture for injection moulding can be established

  18. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    Science.gov (United States)

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  19. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study

    Directory of Open Access Journals (Sweden)

    Sumanth Babu

    2016-01-01

    Full Text Available Aim: The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Materials and Methods: Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA, which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results: Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05 and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05 movement in buccal direction during all stages of denture processing. Conclusion: Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  20. Physical and mechanical properties of pressure-molded and injection-molded denture base acrylics in different conditions

    Directory of Open Access Journals (Sweden)

    Yousef A Shibat Al Hamd

    2014-01-01

    Conclusion: The three tested denture base acrylics did not show any significant differences in processing shrinkage. However, ProBase Hot showed significantly lower bending deflection values than Lucitone 199 and SR-Ivocap. Compared to Lucitone 199 and SR-Ivocap, ProBase Hot is a tougher and a stiffer material. Hence, it is more likely to fracture readily if subjected to extreme loading conditions due to the accidental fall of the denture on a hard surface or if the denture wearer inadvertently bites on a particularly hard particle.

  1. Computational concept for the containment liner for a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Nagelstutz, Franz; Anders, Nils [Babcock Noell GmbH, Wuerzburg (Germany). Abt. Berechnung

    2010-05-15

    The determination of the optimal design of the Containment Liner considering amount of material, manufacturing and erection was the challenge for the engineering team of Babcock Noell GmbH. Several load cases for normal operation and accidental conditions as well as severe accidents have been analyzed. A realistic consideration of impacts by accidents was especially difficult. The special load cases in the vicinity of penetrations and anchor plates have been calculated. The results of theses analyses have been considered in the actual design of the liner. An integrated concept from planning, manufacturing and erection of this large component has been implemented, which is the topic of the speech 'ENGINEERING AND INNOVATIVE ERECTION CONCEPT FOR THE CONTAINMENT LINER FOR AN EPR trademark ' given by Dr. Rainer Goehring, Babcock Noell GmbH, Division Nuclear Technology Projects, Wuerzburg. He demonstrates that within the given time frame, with the required quality and within the required tolerances the containment liner can be erected. (orig.)

  2. Development of Adaptive Acoustic Impedance Control Technologies of Acoustic Duct Liner

    Directory of Open Access Journals (Sweden)

    Hiroshi Kobayashi

    2011-01-01

    Full Text Available This paper describes the development of adaptive acoustic impedance control (AAC technologies to achieve a larger fan noise reduction, by adaptively adjusting reactance and resistance of the acoustic liner impedance. For the actual proof of the AAC technology III performance, the advanced fan noise absorption control duct liner II was made on trial basis, with the simple control system and the plain device. And, then, the duct liner II was examined for the AAC technology I, II, and III models, using the high speed fan test facility. The test results made clear that the duct liner II of the AAC technology III model could achieve the fan noise reduction higher than O.A. SPL 10 dB (A at the maximum fan speed 6000 rpm, containing the reduction of fundamental BPF tone of 18 dB and 2nd BPF tone of 10 dB in response to the fan peed change from 3000 to 6000 rpm.

  3. Effect of thermal shock on mechanical properties of injection-molded thermoplastic denture base resins.

    Science.gov (United States)

    Takahashi, Yutaka; Hamanaka, Ippei; Shimizu, Hiroshi

    2012-07-01

    This study investigated the effect of thermal shock on the mechanical properties of injection-molded thermoplastic denture base resins. Four thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were tested. Specimens of each denture base material were fabricated according to ISO 1567 and were either thermocycled or not thermocycled (n = 10). The flexural strength at the proportional limit (FS-PL), the elastic modulus and the Charpy impact strength of the denture base materials were estimated. Thermocycling significantly decreased the FS-PL of one of the polyamides and the PMMA and it significantly increased the FS-PL of one of the polyamides. In addition, thermocycling significantly decreased the elastic modulus of one of the polyamides and significantly increased the elastic moduli of one of the polyamides, the polyethylene terephthalate, polycarbonate and PMMA. Thermocycling significantly decreased the impact strength of one of the polyamides and the polycarbonate. The mechanical properties of injection-molded thermoplastic denture base resins changed after themocycling.

  4. Treatment of sharp mandibular alveolar process with hybrid prosthesis

    Directory of Open Access Journals (Sweden)

    Sukaedi Sukaedi

    2010-09-01

    Full Text Available Background: Losing posterior teeth for a long time would occasionally lead to the sharpening of alveolar process. The removable partial denture usually have problems when used during mastication, because of the pressure on the mucosa under the alveolar ridge. Purpose: The purpose of this case report was to manage patients with sharp mandibular alveolar process by wearing hybrid prosthesis with extra coronal precision attachment retention and soft liner on the surface base beneath the removable partial denture. Case: A 76 years old woman visited the Prosthodontic Clinic Faculty of Dentistry Airlangga University. The patient had a long span bridge on the upper jaw and a free end acrylic removable partial denture on the lower jaw. She was having problems with mastication. The patient did not wear her lower denture because of the discomfort with it during mastication. Hence, she would like to replace it with a new removable partial denture. Case management: The patient was treated by wearing a hybrid prosthesis with extra coronal precision attachment on the lower jaw. Soft liner was applied on the surface of the removable partial denture. Hybrid prosthesis is a complex denture consisting of removable partial denture and fixed bridge. Conclusion: It concluded that after restoration, the patient had no problems with sharp alveolar process with her new denture, and she was able to masticate well.Latar belakang: Kehilangan geligi posterior dapat menimbulkan processus alveolaris tajam. Gigi tiruan sebagian lepasan mempunyai masalah selama pengunyahan karena adanya tekanan di mukosa di bawah alveolar ridge. Tujuan: Tujuan laporan kasus ini adalah untuk menjelaskan cara menangani pasien yang mempunyai prosesus alveolaris yang tajam di rahang bawah dengan dibuatkan protesis hybrid dengan daya tahan extra coronal precision attachment dan soft liner di permukaan bawah basis gigi tiruan sebagian lepasan. Kasus: Pasien wanita berumur 76 tahun datang di klinik

  5. Clinical evaluation of isolated abutment teeth in removable partial dentures

    Directory of Open Access Journals (Sweden)

    Zarrati S

    2011-02-01

    Full Text Available "nBackground and Aims: Nowadays, removable partial dentures are applied to patients who are not able to use dental implants or fixed prosthesis. Although based on the studies the users of removable partial dentures are in the risk of plaque accumulation and unacceptable changes such as gingivitis, periodontitis and mobility in abutment tooth. It is not clear whether the negative effects of removable partial dentures are more on the isolated teeth which are a kind of abutment adjacent to endentulous area in both sides. The purpose of this study was to investigate the clinical condition of isolated abutment teeth without splinting in comparison to control abutment from the aspects of B.O.P (bleeding on probing, mobility, pocket depth and gingivitis."nMaterials and Methods: In this cross-sectional study, the prepared questionnaires were filled out by 50 patients who received removable partial dentures in department of removable prosthodontics of dental school of Tehran University of Medical Sciences. The patients had isolated abutment tooth and did not have any systemic disease. The obtained data were analyzed. Using Wilcoxon, exact Fisher and Kruskal-Wallis test."nResults: B.O.P (P=0.004, pocket depth (P=0.035, and mobility (P<0.001 in isolated abutments were more than those in control abutments, but there were not significant differences in the degree of caries (P=0.083 and gingivitis (P=0.07."nConclusion: This study showed that clinical condition of isolated abutments is worse than that of control abutments. More attention should be paid to healthiness of isolated teeth without splinting and periodic follow ups should be done in these cases.

  6. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements

    Directory of Open Access Journals (Sweden)

    Moises NOGUEIRA

    Full Text Available Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups (n=10 for upper and lower arches according to polymerization method: 1 conventional one-stage - a wax trial base was made, teeth were arranged and polymerized; 2 two-stage method - the base was waxed and first polymerized. With the denture base polymerized, the teeth were arranged and then, performed the final polymerization. Teeth movements were evaluated in the distances between incisive (I-I, pre-molars (P-P, molars (M-M, left incisor to left molar (LI-LM and right incisor to right molar (RI-RM. For the adaptation analysis, dentures were cut in three different positions: (A distal face of canines, (B mesial face of the first molars, and (C distal face of second molars. Result Denture bases have shown a significant better adaptation when polymerized in the one-stage procedure for both the upper (p=0.000 and the lower (p=0.000 arches, with region A presenting significant better adaptation than region C. In the upper arch, significant reduction in the distance between I-I was observed in the one-stage technique, while the two-stage technique promoted significant reduction in the RI-RM distance. In the lower arch, one-stage technique promoted significant reduction in the distance for RI-RM and two-stage promoted significant reduction in the LI-LM distance. Conclusion Conventional one-stage method presented the better results for denture adaptation. Both fabrication methods presented some alteration in teeth movements.

  7. Effects of the deviation characteristics of nuclear waste emplacement boreholes on borehole liner stresses

    International Nuclear Information System (INIS)

    Glowka, D.A.

    1990-09-01

    This report investigates the effects of borehole deviation on the useability of lined boreholes for the disposal of high-level nuclear waste at the proposed Yucca Mountain Repository in Nevada. Items that lead to constraints on borehole deviation include excessive stresses that could cause liner failure and possible binding of a waste container inside the liner during waste emplacement and retrieval operations. Liner stress models are developed for two general borehole configurations, one for boreholes drilled with a steerable bit and one for boreholes drilled with a non-steerable bit. Procedures are developed for calculating liner stresses that arise both during insertion of the liner into a borehole and during the thermal expansion process that follows waste emplacement. The effects of borehole curvature on the ability of the waste container to pass freely inside the liner without binding are also examined. Based on the results, specifications on borehole deviation allowances are developed for specific vertical and horizontal borehole configurations of current interest. 11 refs., 22 figs., 4 tabs

  8. Shaping the Microstructure of Cast Iron Automobile Cylinder Liners Aimed at Providing High Service Properties

    Directory of Open Access Journals (Sweden)

    Orłowicz A.W.

    2015-06-01

    Full Text Available The paper presents an analysis of factors affecting the wear of cylinder liners. The effect of the graphite precipitation morphology on the cylinder liner wear mechanism is presented. Materials used to cast cylinder liners mounted in a number of engines have been examined for their conformity with requirements set out in applicable Polish industrial standard. A casting for a prototype cylinder liner has been made with a microstructure guaranteeing good service properties of the part.

  9. Comparative evaluation of 2% sodium fluoride iontophoresis and other cavity liners beneath silver amalgam restorations

    Directory of Open Access Journals (Sweden)

    Gupta M

    2010-06-01

    Full Text Available Background: This study was designed to compare 2% sodium fluoride (NaF iontophoresis with other cavity liners. Materials and Methods: This study was carried out in 30 patients in the age group 10-14 years with bilateral carious permanent first molars. The study evaluated the use of 2% NaF iontophoresis as a cavity liner and also compared its desensitizing effect with varnish and an adhesive bonded liner. Sensitivity gradings were done on a subjective verbal rating scale. Results: All the liner treatments decreased the sensitivity following liner application. However, decrease of sensitivity in the case of 2% NaF iontophoresis was more compared with that of varnish and adhesive bonded liner. The results were statistically significant. Conclusions: It was found that 2% NaF iontophoresis was more effective in reducing the postoperative sensitivity compared with that of varnish and scotchbond multipurpose.

  10. Method for baking a liner in thermonuclear device

    International Nuclear Information System (INIS)

    Yamamoto, Keiichi.

    1978-01-01

    Purpose: To attain effective baking for liners in a tokamak device by connecting the narrow portions and the wide portions of the liners with dielectric materials and supplying a constant current to these portions. Method: Split type liners disposed in the vacuum vessel of a thermonuclear device are connected with dielectric materials at their wide portions and narrow portions and they are baked by supplying a constant current at a same density to the wide and narrow portions to rise their temperature uniformly. The wide portions are formed in such a way that the sum of their cross sectional areas is equal to the sum of the cross sectional areas of the narrow portions, and they form a parallel circuit. The parallel circuit consisting of the wide portions and the parallel circuit consisting of the narrow portions are connected in series to each other and connected to the constant current supply circuit, by which a constant current is supplied to the wide and the narrow portions. (Moriyama, K.)

  11. Use of clays as liners in solar ponds

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Gerardo [Facultad de Ingenieria, Universidad Anahuac Mexico Norte, Huixquilucan, Edo. de Mexico 52786 (Mexico); Almanza, Rafael [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Mexico D.F. 04510 (Mexico)

    2009-06-15

    An alternative to synthetic materials for use in solar pond liners is to select clayey soils as hydraulic barriers. This option reduces the cost of construction and the risk of contamination of subsoil and groundwater by hot brines. This paper deals with the physical, chemical and hydraulic properties of different soils tested mainly as compacted clay liners. The underdeveloped nations have the option to use this type of liner, but before doing so several tests are recommended, including those for soil and water composition, permeability, plasticity and X-ray diffraction analysis. In this investigation the following samples are analyzed: native clayey soils with illite, montmorillonite and halloysite, treated and non-treated bentonites in powder and granulated form, a mixture of zeolite and sodium bentonite, and industrial minerals composed largely of halloysite, kaolinite and attapulgite selected clays. Neutral salt aqueous solutions (NaCl and KCl) at different concentrations and under temperature gradients were used for compatibility testing conducted on these specimens. Experiment setup and particular testing procedures are also discussed. (author)

  12. Aging test results of an asphalt membrane liner

    International Nuclear Information System (INIS)

    Buelt, J.L.; Barnes, S.M.

    1983-07-01

    The objective of the asphalt aging study described in this report was to determine the expected performance lifetime of a catalytically airblown asphalt membrane as a seepage barrier for inactive uranium mill tailings. The study, conducted by Pacific Northwest Laboratory for the Department of Energy's Uranium Mill Tailings Remedial Action Program, showed through chemical compatibility tests that the asphalt membrane is well suited for this purpose. The chemical compatibility tests were designed to accelerate the aging reactions in the asphalt and to determine the accelerated aging effect. Higher temperatures and oxygen concentrations proved to be effective acceleration parameters. By infrared spectral analysis, the asphalt was determined to have undergone 7 years of equivalent aging in a 3-month period when exposed to 40 0 C and 1.7 atm oxygen pressure. However, the extent of aging was limited to a maximum penetration of 0.5% of the total liner thickness. It was concluded that the liner could be expected to be effective as a seepage barrier for at least 1000 years before the entire thickness of the liner would be degraded

  13. Liner velocity, current, and symmetry measurements on the 32 MA flux compression generator experiment ALT-1

    CERN Document Server

    Clark, D A; Rodríguez, G; Tabaka, L J

    2001-01-01

    Summary form only given, as follows. A flux compression generator based pulse power system, designed, built, and fielded by a Russian team at the All Russian Scientific Research Institute of Experimental Physics (VNIIEF), was used to successfully drive an aluminum liner to velocities greater than 10 km/sec. The experiment objective was to demonstrate performance of a precision liner implosion at Atlas current of 30 MA or greater. Diagnostics to measure liner performance were an essential part of the experiment. An experimental team from Los Alamos National Laboratory (LANL) provided a suite of diagnostics to measure liner performance. Three diagnostics were fielded. 1. a velocity interferometer (VISAR) to continuously measure the liner inner surface velocity from throughout the entire range of travel. 2. Two Faraday rotation devices to measure liner current during the implosion. 3. Sixteen fiber optic impact pins to record liner impact time and provide axial and azimuthal symmetry information. All diagnostics...

  14. An Investigation into the Trueness and Precision of Copy Denture Templates Produced by Rapid Prototyping and Conventional Means.

    Science.gov (United States)

    Davda, K; Osnes, C; Dillon, S; Wu, J; Hyde, P; Keeling, A

    2017-12-01

    To assess the trueness and precision of copy denture templates produced using traditional methods and 3D printing. Six copies of a denture were made using: 1. Conventional technique with silicone putty in an impression tray (CT). 2. Conventional technique with no impression tray (CNT). 3. 3D scanning and printing (3D). Scan trueness and precision was investigated by scanning a denture six times and comparing five scans to the sixth. Then the scans of the six CT, CNT and 3D dentures were compared by aligning, in turn, the copies of each denture to the scanned original. Outcome measures were the mean surface-to-surface distance, standard deviation of that distance and the maximum distance. Student's unpaired t-tests with Bonferroni correction were used to analyse the results. The repeated scans of the original denture showed a scan trueness of 0.013mm (SD 0.002) and precision of 0.013mm (SD 0.002). Trueness: CT templates, 0.168mm (0.047), CNT templates 0.195mm (0.034) and 3D 0.103mm (0.021). Precision: CT templates 0.158mm (0.037), CNT 0.233mm (0.073), 3D 0.090mm (0.017). For each outcome measure the 3D templates demonstrated an improvement which was statistically significant (p⟨0.05). 3D printed copy denture templates reproduced the original with greater trueness and precision than conventional techniques. Copyright© 2017 Dennis Barber Ltd.

  15. Novel denture-cleaning system based on hydroxyl radical disinfection.

    Science.gov (United States)

    Kanno, Taro; Nakamura, Keisuke; Ikai, Hiroyo; Hayashi, Eisei; Shirato, Midori; Mokudai, Takayuki; Iwasawa, Atsuo; Niwano, Yoshimi; Kohno, Masahiro; Sasaki, Keiichi

    2012-01-01

    The purpose of this study was to evaluate a new denture-cleaning device using hydroxyl radicals generated from photolysis of hydrogen peroxide (H2O2). Electron spin resonance analysis demonstrated that the yield of hydroxyl radicals increased with the concentration of H2O2 and light irradiation time. Staphylococcus aureus, Pseudomonas aeruginosa, and methicillin-resistant S aureus were killed within 10 minutes with a > 5-log reduction when treated with photolysis of 500 mM H2O2; Candida albicans was killed within 30 minutes with a > 4-log reduction with photolysis of 1,000 mM H2O2. The clinical test demonstrated that the device could effectively reduce microorganisms in denture plaque by approximately 7-log order within 20 minutes.

  16. Utilization of sepiolite materials as a bottom liner material in solid waste landfills.

    Science.gov (United States)

    Guney, Yucel; Cetin, Bora; Aydilek, Ahmet H; Tanyu, Burak F; Koparal, Savas

    2014-01-01

    Landfill bottom liners are generally constructed with natural clay soils due to their high strength and low hydraulic conductivity characteristics. However, in recent years it is increasingly difficult to find locally available clay soils that satisfy the required engineering properties. Fine grained soils such as sepiolite and zeolite may be used as alternative materials in the constructions of landfill bottom liners. A study was conducted to investigate the feasibility of using natural clay rich in kaolinite, sepiolite, zeolite, and their mixtures as a bottom liner material. Unconfined compression tests, swell tests, hydraulic conductivity tests, batch and column adsorption tests were performed on each type of soil and sepiolite-zeolite mixtures. The results of the current study indicate that sepiolite is the dominant material that affects both the geomechanical and geoenvironmental properties of these alternative liners. An increase in sepiolite content in the sepiolite-zeolite mixtures increased the strength, swelling potential and metal adsorption capacities of the soil mixtures. Moreover, hydraulic conductivity of the mixtures decreased significantly with the addition of sepiolite. The utilization of sepiolite-zeolite materials as a bottom liner material allowed for thinner liners with some reduction in construction costs compared to use of a kaolinite-rich clay. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. The effect of full denture on memory and depression status in elderly

    Directory of Open Access Journals (Sweden)

    Bahruddin Thalib

    2016-06-01

    Full Text Available Complaint that is most often found in elderly is declining or disappearing memory and tooth loss due to aging. Loss of teeth will cause a disturbance in the function of mastication and reportedly may also contribute to the occurrence of memory disorders and depression. The objective of this study was to analyze the influence of full denture use on memory capacity and depression level in elderly. Study conducted at Oral and Dental Hospital Faculty of Dentistry, University of Hasanuddin. This study was clinical experimental with non-randomized design with pre and post test. Sampling with purposive sampling technique, and there were 6 people who are willing to participate. Memory status measurement using Mini-Mental State Exam (MMSE and level of depression using Geriatric Depression Scale (GDS. Memory status and level of depression measurement performed before using full denture and one month after using full denture. Data were analyzed with statistical pair T-test. With a 95% confidence level, the results showed there is an increase in initial MMSE average value (25.67 to the final MMSE average value (26.83 with statistically significant effect, p 0,05. This study concluded that there was significant influence in using full denture on improved memory status of complete edentulous elderly, and despite there were decreased on level of depression, but it was not statistically significant.

  18. A radiographic template for a two-implant mandibular overdenture using the patient’s existing denture

    Science.gov (United States)

    Huynh-Ba, G; Alexander, P; Vargas, A; Vierra, M; Oates, TW

    2012-01-01

    This article introduces a technique for modifying an existing mandibular complete denture for use as a radiographic template with a radiopaque light-activated calcium hydroxide (Ca(OH)2) preparation. This allows prosthetically-driven treatment planning and surgical placement of 2 implants to support the existing mandibular denture. PMID:23328197

  19. Elastic-plastic cyclic deformation of the TEXTOR 94 modified liner under conditions of heating and plasma disruption

    International Nuclear Information System (INIS)

    Bohn, F.H.; Czymek, G.; Giesen, B.; Bondarchuk, E.; Doinikov, N.; Kozhukhovskaja, N.; Panin, A.

    2001-01-01

    The present liner of the TEXTOR 94 tokamak installed inside the vacuum vessel represents the thin toroidal shell that is rested on the vessel inner surface. In order to integrate the dynamic ergodic divertor into the tokamak the liner design has been drastically changed. The 120 deg. sector of the liner shell facing the ergodic coils system is removed and some additional holes in the liner are provisioned. This demands a new liner supporting system allowing for the liner thermal expansion and taking the electromagnetic load occurring in the liner during plasma disruption. The cyclic elasto-plastic deformations of the liner caused by the electromagnetic forces and temperature rise have been studied. It is shown that the local plastic deformations occur in the liner elements after the first heating and electromagnetic loading. The most thermal stresses take place in the reinforcing structures around the holes because of the thermal expansion difference of the inconel shell and the steel reinforcements. These stresses are coupled with the bending stress due to the electromagnetic loading. Subsequent repetitive loading does not lead to any significant increment of the plastic deformation. After the materials' hardening the structure cyclically works mostly in the elastic range

  20. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    Science.gov (United States)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  1. Assessment of the slowly-imploding liner (LINUS) fusion reactor concept

    International Nuclear Information System (INIS)

    Miller, R.L.; Krakowski, R.A.

    1980-01-01

    Prospects for the slowly-imploding liner (LINUS) fusion reactor concept are reviewed. The concept envisages the nondestructive, repetitive and reversible implosion of a liquid-metal cylindrical annulus (liner) onto field-reversed DT plasmoids. Adiabatic heating of the plasmoid to ignition at ultra-high magnetic fields results in a compact, high power density fusion reactor with unique solutions to several technological problems and potentially favorable economics

  2. [Principles of bone tissue structures interaction with full removable dentures fixed on intraosseous implantates modelling].

    Science.gov (United States)

    Shashmurina, V R; Chumachenko, E N; Olesova, V N; Volozhin, A I

    2008-01-01

    Math modelling "removable dentures-implantate-bone" with size and density of bone tissue as variables was created. It allowed to study biomechanical bases of mandibular bone tissue structures interaction with full removable dentures of different constructions and fixed on intraosseous implantates. Analysis of the received data showed that in the majority of cases it was expedient to recommend 3 bearing (abutments) system of denture making. Rest on 4 and more implantates was appropriate for patients with reduced density of spongy bone and significant mandibular bone atrophy. 2 abutment system can be used in patients with high density of spongy bone and absence of mandibular bone atrophy.

  3. Synergistic Integration of Liner Shipping and Economic Development

    Directory of Open Access Journals (Sweden)

    Edvard Roškar

    2008-07-01

    Full Text Available Liner shipping with all its specific features plays an importantrole in the economic development of a country whose portsare involved. In the strategic goals of maritime policy for the period2005-2009 the European Commission stresses the needfor a sustainable environmental development and economicgrowth. Besides, it points out the necessity for the fulfilment ofall maritime potentials. Yet, individual EU member states frequentlycreate the environment, which discourages the developmentof their own national maritime economy. Unfortunately,this applies also to the Republic of Slovenia. The current paperoffers a detailed analysis of the weaknesses and benefits of theclassical liner shipping in present day.

  4. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  5. Assessment of structural integrity of Monju steel liner against sodium leakage and combustion. Modeling of thinning process of liner due to corrosion in structural analysis

    International Nuclear Information System (INIS)

    Tsukimori, K.; Kato, T.; Furuhashi, I.; Iwata, K.; Akatsu, M.

    2001-01-01

    The lining structure of LMFBR (Liquid Metal cooled Fast Breeder Reactor) has an important role to prohibit leaking sodium from touching a concrete floor in a sodium leakage incident. JNC (Japan Nuclear Cycle Development Institute) experienced a sodium leakage incident in 1995 in the secondary heat transport system room of the prototype LMFBR MONJU. In this incident, a part of the liner was covered with a certain amount of high temperature leaked sodium and its compounds. Visible but small distortion and thinning of the liner were detected, which were due to heating by sodium fire and chemical corrosion, respectively. To simulate the MONJU incident, JNC conducted a series of sodium leakage tests, in one of which severer corrosion (molten salt type corrosion) than that in the MONJU incident was observed. In order to secure the conservativeness in the integrity assessment of the liner, consideration of a severest corrosion process was demanded. This means that the loss of parts of the structure with time should be considered in the structural analyses. In this study a modeling of thinning process of the liner was developed in order to realize reasonable analysis from the point of view of actual phenomena. The concept of the method is to release the stress of the lost region by using artificial creep and reducing Young's modulus. The necessity of this kind of model and the validity was verified through an application analysis of the liner in the secondary heat transport system room of MONJU. (authors)

  6. Assessment of structural integrity of Monju steel liner against sodium leakage and combustion. Strain criterion of the liner material

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, T.; Koi, M. [Japan Nuclear Cycle Development Institute, Ibaraki (Japan)

    2001-07-01

    In a postulated condition of sodium leakage and combustion in the secondary heat transfer system of the prototype Japanese fast breeder reactor Monju, thermal stresses raise in steel liners installed to prevent sodium from contacting to concrete. Excessive strain due to the thermal stresses leads to failure of the liner. This paper proposes a strain criterion below that the mechanical integrity of liner is assured. In-plane thermal expansion causes membrane strain and out-of-plane expansion causes bending strain. Therefore, failure modes to be taken into account are tensile fracture and bending fracture. The strain criterion can be determined based on tensile and bending tests. Tensile tests and three-point bending tests were performed at the temperature range from room temperature to 1000 C. Fracture elongation was measured in both tests. Uniform elongation was also measured in tensile tests. Various factors that can affect the above experimental results, multi-axiality, environmental effects, and creep were examined. Based on the above results, the strain criterion was determined. The criterion is 10% for membrane strain and 30% for membrane plus bending strain in the temperature range of 350 C to 1000 C. For the temperatures less than 350 C, the half of those values is used. (author)

  7. Selection of Liner Materials and Design of Hazardous Water Facilities in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Sahel N. Abduljauwad

    2001-12-01

    Full Text Available Rapid development in Saudi Arabia has produced a broad spectrum of wastes.  In the last two decades, several refineries and petrochemical industries have been established. These industries have produced sludges and other toxic wastes which need proper planning for their handling and disposal. This paper covers design and selection of liner materials for two hazardous waste disposal sites. One of them is located in the Eastern Province of Saudi Arabia, while the second one is located in the Western part. The paper will present complete design details of the natural compacted and geosynthetic soil liners and the leachate collection and removal system for primary liners and leak detection/leachate collection and removal system for secondary liners.

  8. [A phd completed 10. Implant-supported removable partial -dentures in a Kennedy Class I-situation in the mandible].

    Science.gov (United States)

    Jensen-Louwerse, C

    2017-06-01

    Implant-supported removable partial dentures in the mandible often cause problems, which means that patients wear their dentures seldom if at all. A solution is to place implants that the dentures can be snapped onto. There is, however, no consensus about the best position of the implants in the mandible yet. In addition, it is worthwhile to balance the cost of treatment with its effectiveness. In a randomised cross-over clinical trial involving 30 patients with a shortened dental arch, the implant-supported removable partial denture in the mandible was evaluated based on the experience of the patient, mean time of wearing, chewing ability and the clinical and radiographic parameters in relation to 2 different implant positions: 2 in the pre-molar region or 2 in the molar region. The cost-effectiveness of both treatments was also evaluated. From the patient's point of view, the implant-supported removable partial dentures are best supported by implants placed in the molar region. The research also revealed, however, that significantly more bleeding occurred around implants placed in the molar region and from a clinical perspective placement in the pre-molar region would have preference. The cost-effectiveness of the treatment with an implant-supported removable partial denture depends on the choice of outcome measurement and monetary threshold.

  9. Radio frequency identification (RFID) of dentures in long-term care facilities.

    Science.gov (United States)

    Madrid, Carlos; Korsvold, Tové; Rochat, Aline; Abarca, Marcelo

    2012-03-01

    The difficulty of identifying the ownership of lost dentures when found is a common and expensive problem in long term care facilities (LTCFs) and hospitals. The purpose of this study was to evaluate the reliability of using radiofrequency identification (RFID) in the identification of dentures for LTCF residents after 3 and 6 months. Thirty-eight residents of 2 LTCFs in Switzerland agreed to participate after providing informed consent. The tag was programmed with the family and first names of the participants and then inserted in the dentures. After placement of the tag, the information was read. A second and third assessment to review the functioning of the tag occurred at 3 and 6 months, and defective tags (if present) were reported and replaced. The data were analyzed with descriptive statistics. At the 3-month assessment of 34 residents (63 tags) 1 tag was unreadable and 62 tags (98.2%) were operational. At 6 months, the tags of 27 of the enrolled residents (50 tags) were available for review. No examined tag was defective at this time period. Within the limits of this study (number of patients, 6-month time span) RFID appears to be a reliable method of tracking and identifying dentures, with only 1 of 65 devices being unreadable at 3 months and 100% of 50 initially placed tags being readable at the end of the trial. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Clinical Evaluation of Implant-Supported Removable Partial Dentures With a Stress-Breaking Attachment.

    Science.gov (United States)

    Suzuki, Yasunori; Kono, Kentaro; Shimpo, Hidemasa; Sato, Yohei; Ohkubo, Chikahiro

    2017-08-01

    The stress-breaking ball (SBB) attachment can distribute the occlusal force equally between the alveolar ridge and the implants. The purpose of this study was to evaluate the implant-supported distal extension removable partial dentures (RPDs) with SBB attachment in 10 patients who were partially edentulous. This randomized crossover study was designed to compare the function of RPDs with and without healing abutments and SBB attachments to support the posterior aspects of the RPDs. Mandibular jaw movements during mastication and the occlusal force and contact area were measured with a commercially available tracking device and pressure-sensitive sheets. Using a visual analog scale, 4 criteria-chewing, retention, stability, and comfort-were evaluated. All of the data obtained were analyzed using a 1-way analysis of variance (α = 0.05). There were no significant differences in either the mean time or the coefficient of variation among the SBB attachments and healing abutments of implant-supported removable partial dentures (ISRPDs) and conventional removable partial dentures (CRPDs). SBB attachments and healing abutments of ISRPDs had greater forces and contact areas than those of CRPDs with significant differences. For all criteria, patients preferred SBB attachments to healing abutments and CRPDs. The implant-supported distal extension RPDs with SBB attachment improved denture stability and patients' satisfaction.

  11. Implant-supported removable partial dentures in the mandible

    NARCIS (Netherlands)

    Louwerse, Charlotte

    2017-01-01

    Conventional removable partial dentures (RPD) in a free-ending situation in the lower jaw (i.e. only front teeth left) have a poor reputation. Several problems like discomfort and functional problems are frequently encountered, resulting in dissatisfied patients and desperate dentists. By supporting

  12. Resilience Thinking: Integrating Resilience, Adaptability and Transformability

    Directory of Open Access Journals (Sweden)

    Carl Folke

    2010-12-01

    Full Text Available Resilience thinking addresses the dynamics and development of complex social-ecological systems (SES. Three aspects are central: resilience, adaptability and transformability. These aspects interrelate across multiple scales. Resilience in this context is the capacity of a SES to continually change and adapt yet remain within critical thresholds. Adaptability is part of resilience. It represents the capacity to adjust responses to changing external drivers and internal processes and thereby allow for development along the current trajectory (stability domain. Transformability is the capacity to cross thresholds into new development trajectories. Transformational change at smaller scales enables resilience at larger scales. The capacity to transform at smaller scales draws on resilience from multiple scales, making use of crises as windows of opportunity for novelty and innovation, and recombining sources of experience and knowledge to navigate social-ecological transitions. Society must seriously consider ways to foster resilience of smaller more manageable SESs that contribute to Earth System resilience and to explore options for deliberate transformation of SESs that threaten Earth System resilience.

  13. Synthesis of new aluminum nano hybrid composite liner for energy saving in diesel engines

    International Nuclear Information System (INIS)

    Tiruvenkadam, N.; Thyla, P.R.; Senthilkumar, M.; Bharathiraja, M.; Murugesan, A.

    2015-01-01

    Highlights: • Nano hybrid composite cylinder liner (NL) was developed to replace cast iron liner. • NL improved engine performance, combustion and reduced emissions except NO x . • Teardown analysis provides the suitability of NL for diesel engine. • The developed aluminum NL saved 43.75% of weight than cast iron cylinder liner. - Abstract: This work aims to replace the conventional cast iron cylinder liner (CL) in diesel engine by introducing lightweight aluminum (Al) 6061 nano hybrid composite cylinder liner (NL) by analyzing the performance, combustion, and emission characteristics of an engine. NL was fabricated by bottom pouring stir casting technique with nano- and micro-reinforcement materials. Experimental results proved that the use of NL increased brake thermal efficiency, in-cylinder pressure, heat release rate, and reduced carbon monoxide, hydrocarbon, and smoke emission in comparison with CL. However, oxides of nitrogen slightly increased with the use of the new liner. No differences in wear or other issues were noted during the engine teardown after 1 year of operation and 2000 h of running. Thus, NL has been recommended to replace the CL to save the energy and to reap environmental benefits

  14. Uranium-mill-tailings remedial-action project (UMTRAP) cover and liner technology development project

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Freeman, H.D.; Cline, J.F.; Beedlow, P.A.; Buelt, J.L.; Relyea, J.R.; Tamura, T.

    1982-01-01

    Cover and liner systems for uranium mill tailings in the United States must satisfy stringent requirements regarding long-term stability, radon control, and radionuclide and hazardous chemical migration. The cover placed over a tailings pile serves three basic purposes: (1) to reduce the release of radon, (2) to prevent the intrusion of plant roots and burrowing animals into the tailings, and (3) to limit surface erosion. The liner placed under a tailings pile prevents the migration of radionuclides and hazardous chemicals to groundwater. Pacific Northwest Laboratory is developing and evaluating cover and liner systems that meet these objectives and conform to federal standards. The cover and liner technology discussed in this paper involves: (1) single and multilayer earthen cover systems, (2) asphalt emulsion radon barrier systems, (3) biobarrier systems, (4) revegetation and rock covers, and (5) asphalt, clay, and synthetic liner systems. These systems have been tested at the Grand Junction, Colorado, tailings pile, where they have been shown to effectively reduce radon releases and radionuclide and chemical migration

  15. Tendency of spherically imploding plasma liners formed by merging plasma jets to evolve toward spherical symmetry

    International Nuclear Information System (INIS)

    Cassibry, J. T.; Stanic, M.; Hsu, S. C.; Witherspoon, F. D.; Abarzhi, S. I.

    2012-01-01

    We have performed three-dimensional (3D) simulations using smoothed particle hydrodynamics (SPH) in order to study the effects of discrete plasma jets on the processes of plasma liner formation, implosion on vacuum, and expansion. It was found that the pressure histories of the inner portion of the liner from 3D SPH simulations with a uniform liner and with 30 discrete plasma jets were qualitatively and quantitatively similar from peak compression through the complete stagnation of the liner. The 3D simulations with a uniform liner were first benchmarked against results from one-dimensional radiation-hydrodynamic simulations [T. J. Awe et al., Phys. Plasmas 18, 072705 (2011)]. Two-dimensional plots of the pressure field show that the discrete jet SPH case evolves towards a profile that is almost indistinguishable from the SPH case with a uniform liner, thus indicating that non-uniformities due to discrete jets are smeared out by late stages of the implosion. The processes of plasma liner formation and implosion on vacuum were shown to be robust against Rayleigh-Taylor instability growth. Finally, interparticle mixing for a liner imploding on vacuum was investigated. The mixing rate was found to be very small until after the peak compression for the 30 jet simulations.

  16. Influence of connection type on the biomechanical behavior of distal extension mandibular removable partial dentures supported by implants and natural teeth.

    Science.gov (United States)

    Xiao, Wei; Li, Zhiyong; Shen, Shiqian; Chen, Shaowu; Chen, Sulin; Wang, Jiawei

    2016-02-01

    Few studies are performed to evaluate the influence of connection type on the stress distribution of distal extension mandibular removable partial dentures (RPDs) supported by both implants and natural teeth. In this study, five three-dimensional finite element models were prepared to simulate mandibular bilateral partially edentulous arches. Four were RPDs supported by both implants and natural teeth, and the other one was RPDs supported only by natural teeth. The maximum equivalent (EQV) stress values of bone around implants, the abutments, and the mucosa displacements of the related supporting structures were measured. It was found that a non-rigid telescopic coping was more favorable to protect the implant than a rigid telescopic coping. Compared with other connection types, the easy resilient attachment (ERA) system seemed to be effective to associate implant without complications. However, the results obtained in the present study should be cautiously interpreted in the clinic.

  17. Determining color difference thresholds in denture base acrylic resin.

    Science.gov (United States)

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Zheng, Gang

    2015-11-01

    In restorative prostheses, color is important, but the choice of color difference formula used to quantify color change in acrylic resins is not straightforward. The purpose of this in vitro study was to choose a color difference formula that best represented differences between the calculated color and the observed imperceptible to unacceptable color and to determine the corresponding perceptibility and acceptability threshold of color stability for denture base acrylic resins. A total of 291 acrylic resin denture base plates were fabricated and subjected to radiation tests from zero to 42 hours in accordance with ISO 7491:2000. Color was measured with a portable spectrophotometer, and color differences were calculated with 3 International Commission on Illumination (CIE) formulas: CIELab, CMC(1:1), and CIEDE2000. Thirty-four observers with no deficiencies in color perception participated in psychophysical perceptibility and acceptability assessments under controlled conditions in vitro. These 2 types of assessments were regressed to each observer by each formula to generate receiver operator characteristic (ROC) curves. Areas under the curves (AUCs) were then calculated and analyzed to exclude observers with poor color discrimination. AUCs were subjected to 1-way ANOVA (α=.05) to deter the statistical significance of discriminability among the 3 formulas in terms of perceptibility and acceptability judgments. Student-Newman-Keuls tests (α=.05) were used for post hoc comparison. CMC(1:1) and CIEDE2000 formulas performed better for imperceptible to unacceptable color differences, with corresponding CMC(1:1) and CIEDE2000 values for perceptibility of 2.52 and 1.72, respectively, and acceptability thresholds of 6.21 and 4.08, respectively. Formulas CMC(1:1) and CIEDE2000 possess higher discriminability than that of CIELab in the assessment of perceptible color difference threshold of denture base acrylic resin. A statistically significant difference exists

  18. Helium High Pressure Tanks at EADS Space Transportation New Technology with Thermoplastic Liner

    National Research Council Canada - National Science Library

    Benedic, Fabien; Leard, Jean-Philippe; Lefloch, Christian

    2005-01-01

    .... In order to achieve the new target prices, a new disruptive technology has been performing for several years in using a thermoplastic liner instead the usual expensive concept of metallic forged liner...

  19. Plasma Liner Research for MTF at NASA Marshall Space Flight Center

    Science.gov (United States)

    Thio, Y. C. F.; Eskridge, R.; Lee, M.; Martin, A.; Smith, J.; Cassibry, J. T.; Wu, S. T.; Kirkpatrick, R. C.; Knapp, C. E.; Turchi, P. J.; hide

    2002-01-01

    The current research effort at NASA Marshall Space Flight Center (MSFC) in MTF is directed towards exploring the critical physics issues of potential embodiments of MTF for propulsion, especially standoff drivers involving plasma liners for MTF. There are several possible approaches for forming plasma liners. One approach consists of using a spherical array of plasma jets to form a spherical plasma shell imploding towards the center of a magnetized plasma, a compact toroid. Current experimental plan and status to explore the physics of forming a 2-D plasma liner (shell) by merging plasma jets are described. A first-generation coaxial plasma guns (Mark-1) to launch the required plasma jets have been built and tested. Plasma jets have been launched reproducibly with a low jitter, and velocities in excess of 50 km/s for the leading edge of the plasma jet. Some further refinements are being explored for the plasma gun, Successful completion of these single-gun tests will be followed by an experimental exploration of the problems of launching a multiple number of these jets simultaneously to form a cylindrical plasma liner.

  20. Friction Stir Welding of GR-Cop 84 for Combustion Chamber Liners

    Science.gov (United States)

    Russell, Carolyn K.; Carter, Robert; Ellis, David L.; Goudy, Richard

    2004-01-01

    GRCop-84 is a copper-chromium-niobium alloy developed by the Glenn Research Center for liquid rocket engine combustion chamber liners. GRCop-84 exhibits superior properties over conventional copper-base alloys in a liquid hydrogen-oxygen operating environment. The Next Generation Launch Technology program has funded a program to demonstrate scale-up production capabilities of GR-Cop 84 to levels suitable for main combustion chamber production for the prototype rocket engine. This paper describes a novel method of manufacturing the main combustion chamber liner. The process consists of several steps: extrude the GR-Cop 84 powder into billets, roll the billets into plates, bump form the plates into cylinder halves and friction stir weld the halves into a cylinder. The cylinder is then metal spun formed to near net liner dimensions followed by finish machining to the final configuration. This paper describes the friction stir weld process development including tooling and non-destructive inspection techniques, culminating in the successful production of a liner preform completed through spin forming.

  1. The basic design of the Krupp heat-insulating system with hot liner for PCPVs of HTRs

    International Nuclear Information System (INIS)

    Spandick, W.

    1979-01-01

    Presented is the design of a heat-insulating system incorporating a so called ''hot'' liner for use with high temperature reactors. The liner is in direct contact with the coolant, has a thickness of between 10 and 15 mm and is arc welded to anchors embedded in the concrete. Thermal cyclic tests were performed and incipient cracks were detected after about 5000 cycles; the liner is to be designed for between 800 and 1400 cycles. The liner design allows for internal inspection and, if necessary, repair at all times. Tests have shown the advantages of the design provided liner temperatures do not rise above 300 0 C

  2. Design report on the SSCL prototype 80 K Synchrotron Radiation Liner System

    International Nuclear Information System (INIS)

    Shu, Q.S.; Barts, T.; Chou, W.

    1993-09-01

    This report documents the effort to develop a viable design for an SSC prototype 80 K Synchrotron Radiation Liner System. This liner is designed to be tested in the Superconducting Super Collider Accelerator Systems String Test (ASST) facility. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum environment. Secondly, the liner is aimed at improving the Collider cryogenic thermal efficiency which would allow a potential luminosity upgrade. The SSC Collider is the first proton superconducting accelerator designed to operate at an energy of 20 TeV (each beam) and a beam current of 72 mA. The Collider will produce a synchrotron power of 0.14 W/m and a total of 18 kW into 4.2 K for the two rings. This radiated power may trigger a serious impact of photodesorbed gases on the operational availability of the Collider. The interaction between beam particle and photodesorbed gases may greatly reduce the beam lifetime and the scattered beam power may lead to quenching of the superconducting magnets. Collider availability may be unacceptable if this concern is not properly addressed. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum. Secondly, the liner is aimed improving the Collider's cryogenic thermal efficiency which would allow a potential luminosity upgrade. The ultimate goal is to require no more than one machine warm up per year for vacuum maintenance during operation of the SSC Collider

  3. Design report on the SSCL prototype 80 K Synchrotron Radiation Liner System

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Q.S.; Barts, T.; Chou, W. [and others

    1993-09-01

    This report documents the effort to develop a viable design for an SSC prototype 80 K Synchrotron Radiation Liner System. This liner is designed to be tested in the Superconducting Super Collider Accelerator Systems String Test (ASST) facility. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum environment. Secondly, the liner is aimed at improving the Collider cryogenic thermal efficiency which would allow a potential luminosity upgrade. The SSC Collider is the first proton superconducting accelerator designed to operate at an energy of 20 TeV (each beam) and a beam current of 72 mA. The Collider will produce a synchrotron power of 0.14 W/m and a total of 18 kW into 4.2 K for the two rings. This radiated power may trigger a serious impact of photodesorbed gases on the operational availability of the Collider. The interaction between beam particle and photodesorbed gases may greatly reduce the beam lifetime and the scattered beam power may lead to quenching of the superconducting magnets. Collider availability may be unacceptable if this concern is not properly addressed. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum. Secondly, the liner is aimed improving the Collider`s cryogenic thermal efficiency which would allow a potential luminosity upgrade. The ultimate goal is to require no more than one machine warm up per year for vacuum maintenance during operation of the SSC Collider.

  4. The Antifungal Activity and Cytotoxicity of Silver Containing Denture ...

    African Journals Online (AJOL)

    2015-10-30

    Oct 30, 2015 ... Objective: Denture base materials are susceptible to fungal adhesion, which is an important .... (Shimadzu Corp., Kyoto, Japan) to achieve a wavelength ..... assay for detection of cytotoxicity and prediction of acute toxicity.

  5. Telescopic Partial Dentures-Concealed Technology

    OpenAIRE

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-01-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of ?floating plastic? in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental impl...

  6. A review of bias flow liners for acoustic damping in gas turbine combustors

    Science.gov (United States)

    Lahiri, C.; Bake, F.

    2017-07-01

    The optimized design of bias flow liner is a key element for the development of low emission combustion systems in modern gas turbines and aero-engines. The research of bias flow liners has a fairly long history concerning both the parameter dependencies as well as the methods to model the acoustic behaviour of bias flow liners under the variety of different bias and grazing flow conditions. In order to establish an overview over the state of the art, this paper provides a comprehensive review about the published research on bias flow liners and modelling approaches with an extensive study of the most relevant parameters determining the acoustic behaviour of these liners. The paper starts with a historical description of available investigations aiming on the characterization of the bias flow absorption principle. This chronological compendium is extended by the recent and ongoing developments in this field. In a next step the fundamental acoustic property of bias flow liner in terms of the wall impedance is introduced and the different derivations and formulations of this impedance yielding the different published model descriptions are explained and compared. Finally, a parametric study reveals the most relevant parameters for the acoustic damping behaviour of bias flow liners and how this is reflected by the various model representations. Although the general trend of the investigated acoustic behaviour is captured by the different models fairly well for a certain range of parameters, in the transition region between the resonance dominated and the purely bias flow related regime all models lack the correct damping prediction. This seems to be connected to the proper implementation of the reactance as a function of bias flow Mach number.

  7. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    Dual Component Removable Partial Denture (DuCo RPD) is composed of a double base; lower and upper. The lower base, where the artificial teeth are attached, acts as a support and is in contact with the alveolar ridges and oral mucosa. Clasps are designed on the upper base, which acts towards the retention and ...

  8. A matheuristic for the liner shipping network design problem

    DEFF Research Database (Denmark)

    Brouer, Berit Dangaard; Desaulniers, Guy

    2012-01-01

    for revenue and transshipment of cargo along with in/decrease of vessel- and operational cost for the current solution. The evaluation functions may be used by heuristics in general to evaluate changes to a network design without solving a large scale multicommodity flow problem.......We present a matheuristic, an integer programming based heuristic, for the Liner Shipping Network Design Problem. The heuristic applies a greedy construction heuristic based on an interpretation of the liner shipping network design problem as a multiple quadratic knapsack problem. The construction...

  9. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

    Science.gov (United States)

    Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling

    2016-05-01

    Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An

  10. Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-04-01

    This position paper reviews physical and mechanical properties of thermoplastic resin used for non-metal clasp dentures, and describes feature of each thermoplastic resin in clinical application of non-metal clasp dentures and complications based on clinical experience of expert panels. Since products of thermoplastic resin have great variability in physical and mechanical properties, clinicians should utilize them with careful consideration of the specific properties of each product. In general, thermoplastic resin has lower color-stability and higher risk for fracture than polymethyl methacrylate. Additionally, the surface of thermoplastic resin becomes roughened more easily than polymethyl methacrylate. Studies related to material properties of thermoplastic resin, treatment efficacy and follow-up are insufficient to provide definitive conclusions at this time. Therefore, this position paper should be revised based on future studies and a clinical guideline should be provided. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. In the zone - first rotary steerable liner-while-drilling system; Drilling technology

    Energy Technology Data Exchange (ETDEWEB)

    2010-07-01

    Statoil recently successfully tested the world's first rotary steerable liner-while-drilling system from its Brage platform in the Norwegian sector of the North Sea. This innovative technology - with applications in new and mature fields - was jointly developed by Statoil and Baker Hughes Incorporated. The concept of a rotary steerable system that gives operators the ability to accurately drill and log three-dimensional well profiles with a liner attached directly to the drillstring is entirely new. The system is designed to withstand high circulation rates and high torque loads while providing liner connect and disconnect capabilities. (Author)

  12. Patient satisfaction with occlusal scheme of conventional complete dentures: A randomised clinical trial (part I).

    Science.gov (United States)

    Moradpoor, H; Arabzade Hoseini, M; Savabi, O; Shirani, M

    2018-01-01

    Occlusal scheme can affect denture retention, stability, occlusal force distribution, aesthetics, masticatory function, patient comfort and general patient satisfaction with dentures. This study aimed to compare the patient satisfaction with 3 types of complete denture occlusion including fully bilateral balanced occlusion (FBBO), newly presented buccalised occlusion (BO) and lingualised occlusion (LO). In this parallel randomised clinical trial, new conventional complete dentures were fabricated for 86 volunteers. Participants were randomly allocated to 3 groups with 3 different occlusal schemes. All patients were recalled at 1 and 3 months after delivery for data collection. The 19-item version of Oral Health Impact Profile for Edentulous Patients questionnaire was used in this study. The visual analogue scale (VAS) was used for assessment of the prosthodontist's attitude towards denture quality, patient's attitude towards different occlusal schemes and evaluation of patient satisfaction. Data were analysed using the Wilcoxon signed rank test, the Kruskal-Wallis test and the post hoc Dunn test via SPSS version 18.0 (P ≤ .05). Eighty-six patients completed the study, and their data were analysed (mean age ± standard deviation = 57.78 ± 9.98 years). The only significant difference when comparing the 3 groups was physical pain, which was significantly higher in FBBO group. No significant differences were found for the VAS scores of patient and prosthodontist satisfaction or the domain scores among the 3 occlusal schemes either at 1 or at 3 months post-delivery. The VAS score of patient satisfaction and prosthodontist satisfaction increased at third compared to first month after delivery. The results of this randomised clinical trial provided evidence that BO is as effective as LO for the fabrication of complete dentures. © 2017 John Wiley & Sons Ltd.

  13. Can Resilience Thinking Inform Resilience Investments? Learning from Resilience Principles for Disaster Risk Reduction

    Directory of Open Access Journals (Sweden)

    Margot Hill Clarvis

    2015-07-01

    Full Text Available As the human and financial costs of natural disasters rise and state finances continue to deplete, increasing attention is being placed on the role of the private sector to support disaster and climate resilience. However, not only is there a recognised lack of private finance to fill this gap, but international institutional and financing bodies tend to prioritise specific reactive response over preparedness and general resilience building. This paper utilises the central tenets of resilience thinking that have emerged from scholarship on social-ecological system resilience as a lens through which to assess investing in disaster risk reduction (DRR for resilience. It draws on an established framework of resilience principles and examples of resilience investments to explore how resilience principles can actually inform decisions around DRR and resilience investing. It proposes some key lessons for diversifying sources of finance in order to, in turn, enhance “financial resilience”. In doing so, it suggests a series of questions to align investments with resilience building, and to better balance the achievement of the resilience principles with financial requirements such as financial diversification and replicability. It argues for a critical look to be taken at how resilience principles, which focus on longer-term systems perspectives, could complement the focus in DRR on critical and immediate stresses.

  14. Denture acceptance among newly rehabilitated elderly population in old age homes in South India

    Directory of Open Access Journals (Sweden)

    Mallika S Shetty

    2015-01-01

    Full Text Available Introduction: Elders in old age homes are mainly those who have been abandoned by their family and have one or more physical or mental disabilities. It is a major challenge for the dental professional to plan oral health strategy for this group of patients. Aim of the Study: Aim of the present study is to observe and determine the acceptance of new dental prosthesis among the elderly residing as inmates of 3 old age homes in Mangalore City. Materials and Methods: This cross-sectional study was conducted using a survey proforma. Information regarding their experience with the new denture, 1-month, 3 months and 6 months after denture insertion was gathered. Statistical analysis of the data was done using the Chi-square test with the P < 0.05 considered significant. Results: One hundred and eighty-three residents out of a total of 400 residents in 3 old age homes were denture wearers. Among them, 101 (55.2% were females, and 82 (44.8% were males. Dental prosthesis whether worn regularly, discomfort, retention, cleansing of denture during a period of 1-month, 3 months and 6 months was found to be significant satisfaction with the prosthesis, denture adhesives used, food accumulation during a period of 1-month, 3 months and 6 months was found to be nonsignificant. Conclusion: The emotional makeup of the patient must be taken into consideration during the entire procedure. We must understand that the success of the prosthesis depends mainly on the patient′s confidence in the dentist rather than the quality of the prosthesis.

  15. Social determinants of denture/bridge use: Japan gerontological evaluation study project cross-sectional study in older Japanese.

    Science.gov (United States)

    Yamamoto, Tatsuo; Kondo, Katsunori; Aida, Jun; Suzuki, Kayo; Misawa, Jimpei; Nakade, Miyo; Fuchida, Shinya; Hirata, Yukio

    2014-06-03

    Studies suggest that using a denture/bridge may prevent disability in older people. However, not all older people with few remaining teeth use a denture/bridge. This cross-sectional study aimed to examine the social determinants which promote denture/bridge use among older Japanese. A total of 54,388 (25,630 males and 28,758 females) community-dwelling individuals aged 65 or over, living independently, able to perform daily activities, and with 19 or fewer teeth. The dependent variable was denture/bridge use. Socio-demographics, number of teeth, present illness, social participation, social support, and social networks were used as individual-level independent variables. Data for social capital were aggregated and used as local district (n = 561 for males, n = 562 for females) -level independent variables. Number of dentists working in hospitals/clinics per population and population density were used as municipality (n = 28) -level independent variables. Three-level multilevel Poisson regression analysis was performed for each sex. High equivalent income, low number of teeth, present illness, and living in a municipality with high population density were significantly associated with denture/bridge use in both sexes in the fully adjusted models (p social groups in females in the fully adjusted model (p social capital. Denture/bridge use was significantly associated with high economic status and present illness in both sexes, high educational attainment in males, and participation in social groups in females among community-dwelling older Japanese after adjusting for possible confounders.

  16. Evaluation Of Liner Back-pressure Due To Concrete Pore Pressure At Elevated Temperatures

    International Nuclear Information System (INIS)

    James, R.J.; Rashid, Y.R.; Liu, A.S.; Gou, B.

    2006-01-01

    GE's latest evolution of the boiling water reactor, the ESBWR, has innovative passive design features that reduce the number and complexity of active systems, which in turn provide economic advantages while also increasing safety. These passive systems used for emergency cooling also mean that the primary containment system will experience elevated temperatures with longer durations than conventional plants in the event of design basis accidents. During a Loss of Coolant Accident (LOCA), the drywell in the primary containment structure for the ESBWR will be exposed to saturated steam conditions for up to 72 hours following the accident. A containment spray system may be activated that sprays the drywell area with water to condense the steam as part of the recovery operations. The liner back-pressure will build up gradually over the 72 hours as the concrete temperatures increase, and a sudden cool down could cause excessive differential pressure on the liner to develop. For this analysis, it is assumed that the containment spray is activated at the end of the 72-hour period. A back-pressure, acting between the liner and the concrete wall of the containment, can occur as a result of elevated temperatures in the concrete causing steam and saturated vapor pressures to develop from the free water remaining in the pores of the concrete. Additional pore pressure also develops under the elevated temperatures from the non-condensable gases trapped in the concrete pores during the concrete curing process. Any buildup of this pore pressure next to the liner, in excess of the drywell internal pressure, will act to push the liner away from the concrete with a potential for tearing at the liner anchorages. This paper describes the methods and analyses used to quantify this liner back-pressure so that appropriate measures are included in the design of the liner and anchorage system. A pore pressure model is developed that calculates the pressure distribution across the concrete

  17. Evaluation of a stack: A concrete chimney with brick liner

    International Nuclear Information System (INIS)

    Joshi, J.R.; Amin, J.A.; Porthouse, R.A.

    1995-01-01

    A 200 ft. tall stack, consisting of a concrete chimney with an independent acid proof brick liner built in the 1950's, serving the Separations facility at the Savannah River Site (SRS), was evaluated for the performance category 3 (PC3) level of Natural Phenomena Hazards (NPH) effects. The inelastic energy absorption capacity of the concrete chimney was considered in the evaluation of the earthquake resistance, in particular, to compute the F μ factor. The calculated value of F μ exceeded 3.0, while the seismic demand for the PC3 level, using an F μ value of 1.5, was found to be less than the capacity of the concrete chimney. The capacity formulation of ACI 307 was modified to incorporate the effect of an after design opening on the tension side. There are considerable uncertainties in determining the earthquake resistance of the independent brick liner. The critical liner section, located at the bottom of the breeching opening, does not meet the current recommendations. A discussion is provided for the possible acceptable values for the ''Moment Reduction Factor'', R w or F μ for the liner. Comments are provided on the comparison of stack demands using response spectra (RS) versus time history (TH) analysis, with and without soil structure interaction (SSI) effects

  18. 75 FR 1596 - Grant of Authority for Subzone Status, Reynolds Packaging LLC (Aluminum Foil Liner Stock...

    Science.gov (United States)

    2010-01-12

    ... Status, Reynolds Packaging LLC (Aluminum Foil Liner Stock), Louisville, Kentucky Pursuant to its...-purpose subzone at the aluminum foil liner stock manufacturing and distribution facilities of Reynolds... manufacturing and distribution of aluminum foil liner stock and aluminum foil at the facilities of Reynolds...

  19. Evaluation of the structural integrity of LMFBR equipment cell liners: results of preliminary investigations

    International Nuclear Information System (INIS)

    McAfee, W.J.; Sartory, W.K.

    1976-01-01

    The behavior of a plane wall segment of a prototype liquid-metal-cooled fast breeder reactor (LMFBR) cell under conditions of a postulated massive sodium spill was studied. Sodium-concrete reaction calculations were performed assuming an initial flaw existed in the liner such that high-temperature sodium could penetrate to the concrete underneath. Based on existing sodium-concrete reaction rate data, bounding values were established for the maximum energy release per unit volume of concrete. The potential effect of this energy release on the deformation of the liner material was determined. The temperature buildup in the liner and the pressure differential across the flaw in the liner were also studied. The transient thermal and structural responses of the steel liner and backup concrete were analyzed in detail using the inelastic computer code ANSYS. The literature on the mechanical, physical, and general behavior properties of concrete at high temperature was reviewed. This review emphasized the structural behavior of concrete and did not cover the sodium-concrete reaction

  20. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.