WorldWideScience

Sample records for residues monitoring methods

  1. Application of a radiometric enzymic method for monitoring organophosphorus and carbamate insecticide residues in water of the Danube River

    International Nuclear Information System (INIS)

    Horvath, L.; Volford, J.; Bursics, L.; Forster, T.

    1983-01-01

    Pesticide residue analyses are conventionally based on gas chromatography. These analytic procedures include tedious extraction and clear-up manipulations prior to the actual gas chromatographic determinations. Radioenzymatic method was recently applied in a residue monitoring programme on the Danube River. The programme has demonstrated that the radioenzymatic method has many advantages as a monitoring procedure in aquatic environment. Quick information can be gained without tedious sample clear-up procedure. The anticholinesteratic pesticides and the anticholinesteratic activities can be detected

  2. On Line Current Monitoring and Application of a Residual Method for Eccentricity Fault Detection

    Directory of Open Access Journals (Sweden)

    METATLA, A.

    2011-02-01

    Full Text Available This work concerns the monitoring and diagnosis of faults in induction motors. We develop an approach based on residual analysis of stator currents to detect and diagnose faults eccentricity static, dynamic and mixed in three phase induction motor. To simulate the behavior of motor failure, a model is proposed based on the approach of magnetically coupled coils. The simulation results show the importance of the approach applied for the detection and diagnosis of fault in three phase induction motor.

  3. Monitoring antibiotic residues in honey

    Directory of Open Access Journals (Sweden)

    Monica Cristina Cara,

    2011-12-01

    Full Text Available Next to the beta-lactam antibiotics in veterinary medicine, streptomycin is one of the mostly used antibiotics. High concentration of streptomycin could lead to ototoxic and nephrotoxic effects. Low concentration – as found in food – may cause allergies, destroy the intestinal flora and favor immunity to some pathogenic microorganisms. In 1948 chlortetracycline was isolated by Duggan as a metabolite and this was the first antibiotic substance of the group of tetracyclines. In the present paper there are presented the monitoring of the antibiotic residues in honey from Timis County. The residues of tetracycline and streptomycin in honey were determined by the method ELISA – a quantitative method of detection. The microtitre wells are coated with tetracycline and anti-streptomycin antibodies. Free antibiotic and immobilized antibiotic compete with the added antibiotic antibody (competitive immunoassay reaction. Any unbound antibody is then removed in a washing step. Bound conjugate enzymes convert the colorless chromogen into a blue product. The addition ofthe stop reagent leads to a color change from blue to yellow. The measurement is made photometrically at 450 nm. The absorption is inversely proportional to the antibiotic concentration in the sample.

  4. Analytical quality assurance in veterinary drug residue analysis methods: matrix effects determination and monitoring for sulfonamides analysis.

    Science.gov (United States)

    Hoff, Rodrigo Barcellos; Rübensam, Gabriel; Jank, Louise; Barreto, Fabiano; Peralba, Maria do Carmo Ruaro; Pizzolato, Tânia Mara; Silvia Díaz-Cruz, M; Barceló, Damià

    2015-01-01

    In residue analysis of veterinary drugs in foodstuff, matrix effects are one of the most critical points. This work present a discuss considering approaches used to estimate, minimize and monitoring matrix effects in bioanalytical methods. Qualitative and quantitative methods for estimation of matrix effects such as post-column infusion, slopes ratios analysis, calibration curves (mathematical and statistical analysis) and control chart monitoring are discussed using real data. Matrix effects varying in a wide range depending of the analyte and the sample preparation method: pressurized liquid extraction for liver samples show matrix effects from 15.5 to 59.2% while a ultrasound-assisted extraction provide values from 21.7 to 64.3%. The matrix influence was also evaluated: for sulfamethazine analysis, losses of signal were varying from -37 to -96% for fish and eggs, respectively. Advantages and drawbacks are also discussed considering a workflow for matrix effects assessment proposed and applied to real data from sulfonamides residues analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Development of Analytical Method and Monitoring of Veterinary Drug Residues in Korean Animal Products.

    Science.gov (United States)

    Song, Jae-Sang; Park, Su-Jeong; Choi, Jung-Yun; Kim, Jin-Sook; Kang, Myung-Hee; Choi, Bo-Kyung; Hur, Sun Jin

    2016-01-01

    This study was conducted to determine the residual amount of veterinary drugs such as meloxicam, flunixin, and tulathromycin in animal products (beef, pork, horsemeat, and milk). Veterinary drugs have been widely used in the rearing of livestock to prevent and treat diseases. A total of 152 samples were purchased from markets located in major Korean cities (Seoul, Busan, Incheon, Daegu, Daejeon, Gwangju, Ulsan and Jeju), including Jeju. Veterinary drugs were analyzed by liquid chromatography-tandem mass spectrometry according to the Korean Food Standards Code. The resulting data, which are located within 70-120% of recovery range and less than 20% of relative standard deviations, are in compliance with the criteria of CODEX. A total of five veterinary drugs were detected in 152 samples, giving a detection rate of approximately 3.3%; and no food source violated the guideline values. Our result indicated that most of the veterinary drug residues in animal products were below the maximum residue limits specified in Korea.

  6. Triaxial X-Ray Diffraction Method and its Application to Monitor Residual Stress in Surface Layers after High-Feed Milling

    Science.gov (United States)

    Zaušková, Lucia; Czán, Andrej; Šajgalík, Michal; Pobijak, Jozef; Mikloš, Matej

    2017-10-01

    High-feed milling is a milling method characteristic with shallow depth of cut and high feed rate to maximize the amount of removed metal from a part, generating residual stresses in the surface and subsurface layers of the machined parts. The residual stress has a large influence on the functional properties of the components. The article is focused on the application of triaxial x-ray diffraction method to monitor residual stresses after high feed milling. Significance of triaxial measuring method is the capability of measuring in different angles so it is possible to acquire stress tensor containing normal and shear stress components.

  7. Profile Monitors Based on Residual Gas Interaction

    CERN Document Server

    Forck, P; Giacomini, T; Peters, A

    2005-01-01

    The precise determination of transverse beam profiles at high current hadron accelerators has to be performed non-interceptingly. Two methods will be discussed based on the excitation of the residual gas molecules by the beam particles: Firstly, by beam induced fluorescence (BIF) light is emitted from the residual gas molecules and is observed with an image intensified CCD camera. At most laboratories N2 gas is inserted, which has a large cross section for emission in the blue wave length region. Secondly, a larger signal strength is achieved by detecting the ionization products in an Ionization Profile Monitor (IPM). By applying an electric field all ionization products are accelerated toward a spatial resolving Micro-Channel Plate. The signal read-out can either be performed by observing the light from a phosphor screen behind the MCP or electronically by a wire array. Methods to achieve a high spatial resolution and a fast turn-by-turn readout capability are discussed. Even though various approaches at dif...

  8. Intraoperative neuromuscular monitoring site and residual paralysis.

    Science.gov (United States)

    Thilen, Stephan R; Hansen, Bradley E; Ramaiah, Ramesh; Kent, Christopher D; Treggiari, Miriam M; Bhananker, Sanjay M

    2012-11-01

    Residual paralysis is common after general anesthesia involving administration of neuromuscular blocking drugs (NMBDs). Management of NMBDs and reversal is frequently guided by train-of-four (TOF) monitoring. We hypothesized that monitoring of eye muscles is associated with more frequent residual paralysis than monitoring at the adductor pollicis. This prospective cohort study enrolled 180 patients scheduled for elective surgery with anticipated use of NMBDs. Collected variables included monitoring site, age, gender, weight, body mass index, American Society of Anesthesiologists physical status class, type and duration of surgery, type of NMBDs, last and total dose administered, TOF count at time of reversal, dose of neostigmine, and time interval between last dose of NMBDs to quantitative measurement. Upon postanesthesia care unit admission, we measured TOF ratios by acceleromyography at the adductor pollicis. Residual paralysis was defined as a TOF ratio less than 90%. Multivariable logistic regression was used to account for unbalances between the two groups and to adjust for covariates. 150 patients received NMBDs and were included in the analysis. Patients with intraoperative TOF monitoring of eye muscles had significantly greater incidence of residual paralysis than patients monitored at the adductor pollicis (P paralysis was observed in 51/99 (52%) and 11/51 (22%) of patients, respectively. The crude odds ratio was 3.9 (95% CI: 1.8-8.4), and the adjusted odds ratio was 5.5 (95% CI: 2.1-14.5). Patients having qualitative TOF monitoring of eye muscles had a greater than 5-fold higher risk of postoperative residual paralysis than those monitored at the adductor pollicis.

  9. Method for residual household waste composition studies.

    Science.gov (United States)

    Sahimaa, Olli; Hupponen, Mari; Horttanainen, Mika; Sorvari, Jaana

    2015-12-01

    The rising awareness of decreasing natural resources has brought forward the idea of a circular economy and resource efficiency in Europe. As a part of this movement, European countries have identified the need to monitor residual waste flows in order to make recycling more efficient. In Finland, studies on the composition of residual household waste have mostly been conducted using different methods, which makes the comparison of the results difficult. The aim of this study was to develop a reliable method for residual household waste composition studies. First, a literature review on European study methods was performed. Also, 19 Finnish waste composition studies were compared in order to identify the shortcomings of the current Finnish residual household waste composition data. Moreover, the information needs of different waste management authorities concerning residual household waste were studied through a survey and personal interviews. Stratification, sampling, the classification of fractions and statistical analysis were identified as the key factors in a residual household waste composition study. The area studied should be divided into non-overlapping strata in order to decrease the heterogeneity of waste and enable comparisons between different waste producers. A minimum of six subsamples, each 100 kg, from each stratum should be sorted. Confidence intervals for each waste category should be determined in order to evaluate the applicability of the results. A new three-level classification system was created based on Finnish stakeholders' information needs and compared to four other European waste composition study classifications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The Cauchy method of residues

    CERN Document Server

    Mitrinović, Dragoslav S

    1993-01-01

    Volume 1, i. e. the monograph The Cauchy Method of Residues - Theory and Applications published by D. Reidel Publishing Company in 1984 is the only book that covers all known applications of the calculus of residues. They range from the theory of equations, theory of numbers, matrix analysis, evaluation of real definite integrals, summation of finite and infinite series, expansions of functions into infinite series and products, ordinary and partial differential equations, mathematical and theoretical physics, to the calculus of finite differences and difference equations. The appearance of Volume 1 was acknowledged by the mathematical community. Favourable reviews and many private communications encouraged the authors to continue their work, the result being the present book, Volume 2, a sequel to Volume 1. We mention that Volume 1 is a revised, extended and updated translation of the book Cauchyjev raeun ostataka sa primenama published in Serbian by Nau~na knjiga, Belgrade in 1978, whereas the greater part ...

  11. Monitoring residue in animals and primary products of animal origin

    Directory of Open Access Journals (Sweden)

    Janković Saša

    2008-01-01

    Full Text Available The objective of control and systematic monitoring of residue is to secure, by the examination of a corresponding number of samples, the efficient monitoring of the residue level in tissues and organs of animals, as well as in primary products of animal origin. This creates possibilities for the timely taking of measures toward the securing of food hygiene of animal origin and the protection of public health. Residue can be a consequence of the inadequate use of medicines in veterinary medicine and pesticides in agriculture and veterinary medicine, as well as the polluting of the environment with toxic elements, dioxins, polychlorinated biphenyls, and others. Residue is being monitored in Serbia since 1972, and in 2004, national monitoring was brought to the level of EU countries through significant investments by the Ministry of Agriculture, Forestry and Water Management. This is also evident in the EU directives which permit exports of all kinds of meat and primary products of animal origin, covered by the Residue Monitoring Program. The program of systematic examinations of residue has been coordinated with the requirements of the European Union, both according to the type of examined substance, as well as according to the number of samples and the applied analytical techniques. In addition to the development of methods and the including of new harmful substances into the monitoring programme, it is also necessary to coordinate the national regulations that define the maximum permitted quantities of certain medicines and contaminants with the EU regulations, in order to protect the health of consumers as efficiently as possible, and for the country to take equal part in international trade.

  12. Monitoring of Benomyl Residue in Mushroom Marketed in Hamadan City

    Directory of Open Access Journals (Sweden)

    S. Abdi

    2015-07-01

    Full Text Available Introduction & Objective: Pesticide residues in environment and food have a negative impact on the health of living organisms. Therefore, this study was carried out for evaluation of benomyl residues in mushroom marketed in Hamadan city in 2014 using spectrophotometry. Materials & Methods: 10 specimens of mushroom were collected from greenhouses and market basket of Hamadan city. After preparation and processing the samples in the laboratory, be-nomyl residues in samples were determined using a spectrophotometric method in 3 replica-tions. All statistical analyses were performed using the SPSS statistical package. Results: The mean concentration of benomyl residues in samples were 5.90±0.75, 2.10± 0.487, 40.04±1.346, 0.32±0.044, 14.0±0.785, 1.54±0.304, 40.0±0.45, 0.87±0.055, 0.66± 0.032 and 49.60±0.303 µg kg-1 and more than the maximum residue limit (MRL provided by the World Health Organization (10 ppb. The results of the comparison of the mean concentration of pesticide residues among samples revealed significant differences in most of the samples (P<0.05. Conclusion: The results showed that mean concentrations of benomyl residues in mushroom samples were exceeding that of the MRL. Therefore, it is essential to impart proper education to the farming community about hazards involved in the overuse of toxic pesticides. Also, codification of laws and their enforcement and implementation of programs for the regular periodic monitoring of pesticide residues in foodstuffs especially in vegetables cultivated un-der greenhouse conditions at the national level to protect consumers’ health are recom-mended.(Sci J Hamadan Univ Med Sci 2015; 22 (2: 137-143

  13. A multi-residue method for pesticides analysis in green coffee beans using gas chromatography-negative chemical ionization mass spectrometry in selective ion monitoring mode.

    Science.gov (United States)

    Pizzutti, Ionara R; de Kok, Andre; Dickow Cardoso, Carmem; Reichert, Bárbara; de Kroon, Marijke; Wind, Wouter; Weber Righi, Laís; Caiel da Silva, Rosselei

    2012-08-17

    In this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation. Aliquots from this extract could be used directly for LC-MS/MS analysis of mycotoxins and LC-amenable pesticides. For GC-MS analysis, a further clean-up was necessary. C18- and PSA-bonded silica were tested as dispersive solid-phase extraction (d-SPE) sorbents, separate and as a mixture, and the best results were obtained using C18-bonded silica. For the optimal sensitivity and selectivity, GC-MS detection in the NCI-selected ion monitoring (SIM) mode had to be used to allow the fast analysis of the difficult coffee bean matrix. The validation was performed by analyzing recovery samples at three different spike concentrations, 10, 20 and 50 μg kg(-1), with 6 replicates (n=6) at each concentration. Linearity (r(2)) of calibration curves, estimated instrument and method limits of detection and limits of quantification (LOD(i), LOD(m), LOQ(i) and LOQ(m), respectively), accuracy (as recovery %), precision (as RSD%) and matrix effects (%) were determined for each individual pesticide. From the 51 analytes (42 parent pesticides, 4 isomers and 5 degradation products) determined by GC-MS (NCI-SIM), approximately 76% showed average recoveries between 70-120% and 75% and RSD ≤ 20% at the lowest spike concentration of 10 μg kg(-1), the target method LOQ. For the

  14. Evaluation of a new modified QuEChERS method for the monitoring of carbamate residues in high-fat cheeses by using UHPLC-MS/MS.

    Science.gov (United States)

    Hamed, Ahmed M; Moreno-González, David; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2017-01-01

    A simple and efficient method for the determination of 28 carbamates in high-fat cheeses is proposed. The methodology is based on a modified quick, easy, cheap, effective, rugged, and safe procedure as sample treatment using a new sorbent (Z-Sep + ) followed by ultra-high performance liquid chromatography with tandem mass spectrometry determination. The method has been validated in different kinds of cheese (Gorgonzola, Roquefort, and Camembert), achieving recoveries of 70-115%, relative standard deviations lower than 13% and limits of quantification lower than 5.4 μg/kg, below the maximum residue levels tolerated for these compounds by the European legislation. The matrix effect was lower than ±30% for all the studied pesticides. The combination of ultra-high performance liquid chromatography and tandem mass spectrometry with this modified quick, easy, cheap, effective, rugged, and safe procedure using Z-Sep + allowed a high sample throughput and an efficient cleaning of extracts for the control of these residues in cheeses with a high fat content. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. VPD residue search by monitoring scattered x-rays

    International Nuclear Information System (INIS)

    Mori, Y.; Yamagami, M.; Yamada, T.

    2000-01-01

    Recently, VPD-TXRF has come into wide use for semiconductor analysis. In VPD-TXRF technique, adjusting the mechanical measuring point to the center of dried residue is of importance for accurate determination. Until now, the following searching methods have been used: monitoring light scattering under bright illumination, using laser scattering particle mapper, applying internal standard as a marker. However, each method has individual disadvantage. For example, interference of Kβ line (ex. Sc-Kβ to Ti-Kα) occurs in the internal standard method. We propose a new searching method 'scattered x-ray search' which utilizes x-ray scattering form the dried residue as a marker. Since the line profile of x-ray scattering agrees with that of fluorescent x-rays, scattered x-ray can be used as an alternative marker instead of internal standard. According to our experimental results, this search method shows the same accuracy as internal standard method. The merits are as follows: 1) no need to add internal standard, 2) rapid search because of high intensity of scattered x-rays, 3) searching software for internal standard can be applied without any modification. In this method, diffraction of incident x-rays by substrate causes irregular change over the detected scattering x-rays. Therefore, this method works better under x-y controlled stage than r-Θ one. (author)

  16. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  17. Nuclear methods monitor nutrition

    International Nuclear Information System (INIS)

    Allen, B.J.

    1988-01-01

    Neutron activation of nitrogen and hydrogen in the body, the isotope dilution technique and the measurement of naturally radioactive potassium in the body are among the new nuclear methods, now under collaborative development by the Australian Nuclear Scientific and Technology Organization and medical specialists from several Sydney hospitals. These methods allow medical specialists to monitor the patient's response to various diets and dietary treatments in cases of cystic fibrosis, anorexia nervosa, long-term surgical trauma, renal diseases and AIDS. ills

  18. Geostatistical methods applied to field model residuals

    DEFF Research Database (Denmark)

    Maule, Fox; Mosegaard, K.; Olsen, Nils

    consists of measurement errors and unmodelled signal), and is typically assumed to be uncorrelated and Gaussian distributed. We have applied geostatistical methods to analyse the residuals of the Oersted(09d/04) field model [http://www.dsri.dk/Oersted/Field_models/IGRF_2005_candidates/], which is based......The geomagnetic field varies on a variety of time- and length scales, which are only rudimentary considered in most present field models. The part of the observed field that can not be explained by a given model, the model residuals, is often considered as an estimate of the data uncertainty (which...... on 5 years of Ørsted and CHAMP data, and includes secular variation and acceleration, as well as low-degree external (magnetospheric) and induced fields. The analysis is done in order to find the statistical behaviour of the space-time structure of the residuals, as a proxy for the data covariances...

  19. Method for radioactivity monitoring

    Science.gov (United States)

    Umbarger, C. John; Cowder, Leo R.

    1976-10-26

    The disclosure relates to a method for analyzing uranium and/or thorium contents of liquid effluents preferably utilizing a sample containing counting chamber. Basically, 185.7-keV gamma rays following .sup.235 U alpha decay to .sup.231 Th which indicate .sup.235 U content and a 63-keV gamma ray doublet found in the nucleus of .sup.234 Pa, a granddaughter of .sup.238 U, are monitored and the ratio thereof taken to derive uranium content and isotopic enrichment .sup.235 U/.sup.235 U + .sup.238 U) in the liquid effluent. Thorium content is determined by monitoring the intensity of 238-keV gamma rays from the nucleus of .sup.212 Bi in the decay chain of .sup.232 Th.

  20. Iterative Regularization with Minimum-Residual Methods

    DEFF Research Database (Denmark)

    Jensen, Toke Koldborg; Hansen, Per Christian

    2007-01-01

    subspaces. We provide a combination of theory and numerical examples, and our analysis confirms the experience that MINRES and MR-II can work as general regularization methods. We also demonstrate theoretically and experimentally that the same is not true, in general, for GMRES and RRGMRES their success......We study the regularization properties of iterative minimum-residual methods applied to discrete ill-posed problems. In these methods, the projection onto the underlying Krylov subspace acts as a regularizer, and the emphasis of this work is on the role played by the basis vectors of these Krylov...... as regularization methods is highly problem dependent....

  1. Iterative regularization with minimum-residual methods

    DEFF Research Database (Denmark)

    Jensen, Toke Koldborg; Hansen, Per Christian

    2006-01-01

    subspaces. We provide a combination of theory and numerical examples, and our analysis confirms the experience that MINRES and MR-II can work as general regularization methods. We also demonstrate theoretically and experimentally that the same is not true, in general, for GMRES and RRGMRES - their success......We study the regularization properties of iterative minimum-residual methods applied to discrete ill-posed problems. In these methods, the projection onto the underlying Krylov subspace acts as a regularizer, and the emphasis of this work is on the role played by the basis vectors of these Krylov...... as regularization methods is highly problem dependent....

  2. Monitoring glyphosate residues in transgenic glyphosate-resistant soybean.

    Science.gov (United States)

    Arregui, María C; Lenardón, Argelia; Sanchez, Daniel; Maitre, María I; Scotta, Roberto; Enrique, Susana

    2004-02-01

    The availability of Roundup Ready (RR) varieties of soybean has increased the use of glyphosate for weed control in Argentina. Glyphosate [(N-phosphonomethyl)glycine] is employed for the eradication of previous crop vegetation and for weed control during the soybean growing cycle. Its action is effective, and low environmental impact has been reported so far. No residues have been observed in soil or water, either of glyphosate or its metabolite, AMPA (aminomethylphosphonic acid). The objective of this work was to monitor glyphosate and AMPA residues in soybean plants and grains in field crops in Santa Fe Province, Argentina. Five sites were monitored in 1997, 1998 and 1999. Individual soybean plants were sampled from emergence to harvest, dried and ground. Analysis consisted in residue extraction with organic solvents and buffers, agitation, centrifugation, clean-up and HPLC with UV detection. In soybean leaves and stems, glyphosate residues ranged from 1.9 to 4.4 mg kg(-1) and from 0.1 to 1.8 mg kg(-1) in grains. Higher concentrations were detected when glyphosate was sprayed several times during the crop cycle, and when treatments approached the flowering stage. AMPA residues were also detected in leaves and in grains, indicating metabolism of the herbicide.

  3. Minimal residual method stronger than polynomial preconditioning

    Energy Technology Data Exchange (ETDEWEB)

    Faber, V.; Joubert, W.; Knill, E. [Los Alamos National Lab., NM (United States)] [and others

    1994-12-31

    Two popular methods for solving symmetric and nonsymmetric systems of equations are the minimal residual method, implemented by algorithms such as GMRES, and polynomial preconditioning methods. In this study results are given on the convergence rates of these methods for various classes of matrices. It is shown that for some matrices, such as normal matrices, the convergence rates for GMRES and for the optimal polynomial preconditioning are the same, and for other matrices such as the upper triangular Toeplitz matrices, it is at least assured that if one method converges then the other must converge. On the other hand, it is shown that matrices exist for which restarted GMRES always converges but any polynomial preconditioning of corresponding degree makes no progress toward the solution for some initial error. The implications of these results for these and other iterative methods are discussed.

  4. DEFECT MONITORING IN IRON CASTING USING RESIDUES OF AUTOREGRESSIVE MODELS

    Directory of Open Access Journals (Sweden)

    Vanusa Andrea Casarin

    2013-06-01

    Full Text Available The purpose of this study is to monitor the index of general waste irons forecasting nodular and gray using the residues originated from the methodology Box & Jenkins by means of X-bar and R control charts. Search is to find a general class of model ARIMA (p, d, q but as data have autocorrelation is found to the number of residues which allowed the application of charts. The found model was the model SARIMA (0,1,1(0,1,1 . In step of checking the stability of the model was found that some comments are out of control due to temperature and chemical composition.

  5. Residual replacement strategies for Krylov subspace iterative methods for the convergence of true residuals

    NARCIS (Netherlands)

    Vorst, H.A. van der; Ye, Q.

    1999-01-01

    In this paper, a strategy is proposed for alternative computations of the residual vectors in Krylov subspace methods, which improves the agreement of the computed residuals and the true residuals to the level of O(u)kAkkxk. Building on earlier ideas on residual replacement and on insights in

  6. Determination of ractopamine in animal hair: application to residue depletion in sheep and residue monitoring.

    Science.gov (United States)

    Suo, Decheng; Zhao, Genlong; Wang, Ruiguo; Su, Xiaoou

    2014-12-01

    An ultra-performance liquid chromatography tandem mass spectrometry method to determine ractopamine (RAC) in hair samples from swine, sheep, and cattle was developed. The procedure to extract from incurred hair was optimized. The samples were extracted with 0.1mol/L HCl solution. The mixture was heated to 60°C in water bath for 4h. The extracts were purified by solid-phase extraction, dried under a stream of nitrogen, and then reconstituted in mobile phase for analysis, which was performed with a Waters BEH-C18 column. The limit of detection was 0.3ng/g, the limit of quantification was 1ng/g, the recoveries were between 87% and 105%, and the coefficient of variation was less than 15%. The depletion of RAC in hair was studied in healthy sheep after administration of RAC at 1000ng/g body weight for five consecutive days. The RAC residues were still detected with 82.5±7.2ng/g hair 27 days after drug administration. Five samples tested positive, in which the amount of RAC detected was 13-253ng/g from 569 hair samples collected from farms and slaughterhouses. These results show that animal hair is a suitable medium to monitor the illegal use of RAC in livestock production. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Three years monitoring survey of pesticide residues in Sardinia wines following integrated pest management strategies.

    Science.gov (United States)

    Angioni, Alberto; Dedola, Fabrizio

    2013-05-01

    This paper reports the results of a pesticide monitoring survey on wine grapes from the 2008-2010 vintage from vineyards grown according to integrated pest management strategies. A multi-residue gas chromatography-mass spectrometry method in electron ionization and chemical ionization mode has been used for the determination of 30 pesticides in wine samples. The analytical method showed good recoveries and allowed a good separation of the selected pesticides. Repeatability and intermediate precision showed good results with CV < 20 %. The instrumental method limits of determination (LOD) and of quantification (LOQ) were below the maximum residue levels set in wine. The analysis of the wines showed that pesticide residues were below the instrumental LOQ, and most of them were undetectable (residues.

  8. Rapid Methods for detection of Veterinary Drug residues in Meat

    Directory of Open Access Journals (Sweden)

    Chandan

    2010-10-01

    Full Text Available The use of substances having hormonal or thyreostatic action as well as b-agonists is banned in many countries. However, sometimes forbidden drugs may be added to feeds for illegal administration to farm animals for promoting increased muscle development or increased water retention and thus obtain an economical benefit. The result is a fraudulent overweight of meat but, what is worse, residues of these substances may remain in meat and may pose a real threat to the consumer either through exposure to the residues, transfer of antibiotic resistance or allergy risk. This has exerted a great concern among the meat consumers. The control of the absence of these forbidden substances in animal foods and feeds is regulated in the European Union by Directive 96/23/EC on measures to monitor certain substances and residues in live animals and animal products. Analytical methodology, including criteria for identification and confirmation, for the monitoring of compliance was also given in Decisions 93/256/EEC and 93/257/EEC. More recently, Decision 2002/657/EC provided rules for the analytical methods to be used in testing of official samples. New substances with anabolic properties are being detected year by year increasing the list of forbidden compounds to be tested. Furthermore, the extended practice consisting in the use of “cocktails” (mixtures of low amounts of several substances that exert a synergistic effect to have a similar growth promotion, reduces the margin for an effective analytical detection. Thus, the evolution of the “black market” is making really difficult to have an effective analytical control of the residues of these substances in foods of animal origin. Control laboratories must face an increasing demand of analysis like the growing number of residues to be analysed in different types of samples, the strict guidelines for analytical methodologies according to the latest Directives, the increased costs of such new

  9. RESIDUAL-GAS-IONIZATION BEAM PROFILE MONITORS IN RHIC.

    Energy Technology Data Exchange (ETDEWEB)

    CONNOLLY, R.; MICHNOFF, R.; TEPIKIAN, S.

    2005-05-16

    Four ionization profile monitors (IPMs) in RHIC measure vertical and horizontal beam profiles in the two rings by measuring the distribution of electrons produced by beam ionization of residual gas. During the last three years both the collection accuracy and signal/noise ratio have been improved. An electron source is mounted across the beam pipe from the collector to monitor microchannel plate (MCP) aging and the signal electrons are gated to reduce MCP aging and to allow charge replenishment between single-turn measurements. Software changes permit simultaneous measurements of any number of individual bunches in the ring. This has been used to measure emittance growth rates on six bunches of varying intensities in a single store. Also the software supports FFT analysis of turn-by-turn profiles of a single bunch at injection to detect dipole and quadrupole oscillations.

  10. Method of producing pitch (distillation residue)

    Energy Technology Data Exchange (ETDEWEB)

    Stepanenko, M.A.; Belkina, T.V.; Krysin, V.P.

    1979-08-15

    A method is proposed for producing pitch by mixing hard coal pitch with anthracene fraction and thermal treatment of the mixture. The method is distinguished in that in order to increase the quality of the pitch, the anthracene fraction is subjected to thermal treatment at 250-300/sup 0/ for 10-13 hours in the presence of air. This duration of heat treatment allows one to build up in the anthracene fraction up to 20-24% of material which is not soluble and toluene, without the formation of products which are not soluble in quinoline. The fraction prepared in this manner is inserted into the initial pitch in the ratio 1:2 up to 1:9, the mixture is subject to heat treatment at temperature 360-380/sup 0/ and air consumption 7-91/kgX hours until the production of pitch with softening temperature of 85-90/sup 0/. As the initial raw material we used pitch with softening temperature of 60/sup 0/, content of substances which are not soluble in quinoline, 2.0% which are not soluble and toluene 20.6% and coking residue of 49.2%. Example. 80 grams of anthracene fraction is added to 320 grams of pitch. The anthracene fraction is subjected previously to heat treatment at 300/sup 0/ for 13 hours in the presence of air, supplied in the amount of 9 liters per hour. As a result of the heat treatment of the content of materials which are not soluble in toluence in the anthracene fraction is 24.0%, in quinoline it is 0.1%. The ratio of a pitch and thermally treated anthracene fraction in the mixture was 4:l. The produced mixture was subjected to heat treatment at 360/sup 0/ for 1.5 hours with air supply in the amount of 7 liters/ kilograms/hours. Pitch is produced with the following characteristics: softening temperature 88/sup 0/, content of substances which are not soluble in toluene 32.5%, in quinilone, 6.0%, coking residue, 56.7%. The invention can be used in the chemical coking and petrochemical industry.

  11. Research and application of residual stress monitor based on magneto-elastic effect

    International Nuclear Information System (INIS)

    Luu Vu Nhut; Luong Thi Hong; Vu Xuan Thanh; Nguyen Viet Hung

    2015-01-01

    Residual stresses can play a significant role in explaining of deformation and crack in weld joints. There are many methods of residual stress measurement. Most commonly methods used in industry and academia are considered: X-ray and neutron diffraction, hole drilling, Barkhausen, eddy current and ultrasonic methods. This paper introduces a new method for stress measurement, which is based on magneto-elastic effect, is a nondestructive method, available to assist evaluate and monitor the stress level, concentration and the gradient which are very important parameters for the evaluation and assessment of predicted life of the components and preventive care. The paper also reports on research which involved diagnostics and assessment of stressed state in butt weld plate before and after heat treatment. (author)

  12. The method for measuring residual stress in stainless steel pipes

    International Nuclear Information System (INIS)

    Shimov, Georgy; Rozenbaum, Mikhail; Serebryakov, Alexandr; Serebryakov, Andrey

    2016-01-01

    The main reason of appearance and growth of corrosion damages of the nuclear steam generator heat exchanger tubes is the process of stress-corrosion cracking of metal under the influence of residual tensile stress. Methods used in the production for estimating residual stresses (such as a method of ring samples) allow measuring only the average tangential stress of the pipe wall. The method of ring samples does not allow to assess the level of residual stress in the surface layer of the pipe. This paper describes an experimental method for measuring the residual stresses on the pipe surface by etching a thin surface layer of the metal. The construction and working principle of a trial installation are described. The residual stresses in the wall of the tubes 16 × 1.5 mm (steel AISI 321) for nuclear steam generators is calculated. Keywords: heat exchange pipes, stress corrosion cracking, residual stresses, stress distribution, stress measurement.

  13. Satellite Magnetic Residuals Investigated With Geostatistical Methods

    DEFF Research Database (Denmark)

    Fox Maule, Chaterine; Mosegaard, Klaus; Olsen, Nils

    2005-01-01

    The geomagnetic field varies on a variety of time- and length scales, which are only rudimentarily considered in most present field models. The part of the observed field that cannot be explained by a given model, the model residuals, is often considered as an estimate of the data uncertainty (wh...

  14. The new method for the residual gas density measurements

    CERN Document Server

    Anashin, V V; Krasnov, A A; Malyshev, O B; Nas'mov, V P; Pyata, E I; Shaftan, T V

    2001-01-01

    A new method of measurement for residual gas density in the vacuum chambers in presence of synchrotron radiation (SR) is described. The method is based on using a photomultiplier tube for the detection of the SR-stimulated residual gas luminescence, which is proportional to the residual gas density and SR intensity. The design of the experimental setup and results of the measurements of densities of residual gases (H sub 2 , CO sub 2 , CO, N sub 2 , Ar and O sub 2) are submitted.

  15. Minimal Residual Disease Assessment in Lymphoma: Methods and Applications.

    Science.gov (United States)

    Herrera, Alex F; Armand, Philippe

    2017-12-01

    Standard methods for disease response assessment in patients with lymphoma, including positron emission tomography and computed tomography scans, are imperfect. In other hematologic malignancies, particularly leukemias, the ability to detect minimal residual disease (MRD) is increasingly influencing treatment paradigms. However, in many subtypes of lymphoma, the application of MRD assessment techniques, like flow cytometry or polymerase chain reaction-based methods, has been challenging because of the absence of readily detected circulating disease or canonic chromosomal translocations. Newer MRD detection methods that use next-generation sequencing have yielded promising results in a number of lymphoma subtypes, fueling the hope that MRD detection may soon be applicable in clinical practice for most patients with lymphoma. MRD assessment can provide real-time information about tumor burden and response to therapy, noninvasive genomic profiling, and monitoring of clonal dynamics, allowing for many possible applications that could significantly affect the care of patients with lymphoma. Further validation of MRD assessment methods, including the incorporation of MRD assessment into clinical trials in patients with lymphoma, will be critical to determine how best to deploy MRD testing in routine practice and whether MRD assessment can ultimately bring us closer to the goal of personalized lymphoma care. In this review article, we describe the methods available for detecting MRD in patients with lymphoma and their relative advantages and disadvantages. We discuss preliminary results supporting the potential applications for MRD testing in the care of patients with lymphoma and strategies for including MRD assessment in lymphoma clinical trials.

  16. Monitoring of Some Pesticides Residue in Consumed tea in Tehran Market

    Directory of Open Access Journals (Sweden)

    Maryam Amirahmadi

    2013-01-01

    Full Text Available Tea is an agricultural product of the leaves, leaf buds, and internodes of various cultivars and sub-varieties of the Camellia sinensis plant, processed and vulcanized using various methods. Tea is a main beverage in Iranian food basket so should be free from toxic elements such as pesticides residue. There is no data bank on the residue of pesticides in the consumed black tea in Iran. The present study is the first attempt for monitoring of 25 pesticide residues from different chemical groups in tea samples obtained from local markets in Tehran, I.R. Iran during the period 2011. A reliable and accurate method based on spiked calibration curve and QuEChERS sample preparation was developed for determination of pesticide residues in tea by gas chromatography--mass spectrometry (GC/MS. The using of spiked calibration standards for constructing the calibration curve substantially reduced adverse matrix-related effects and negative recovery affected by GCB on pesticides. The recovery of pesticides at 3 concentration levels (n = 3 was in range of 81.4 - 99.4%. The method was proved to be repeatable with RSDr lower than 20%. The limits of quantification for all pesticides were <=20 ng/g. 53 samples from 17 imported and manufactured brand were analyzed. Detectable pesticides residues were found in 28.3% (15 samples of the samples. All of the positive samples were contaminated with unregulated pesticides (Endosulfan Sulfate or Bifenthrin which are established by ISIRI. None of the samples had contamination higher than maximum residue limit set by EU and India.

  17. Monitoring of some pesticides residue in consumed tea in Tehran market

    Directory of Open Access Journals (Sweden)

    Hamedani Morteza Pirali

    2013-01-01

    Full Text Available Abstract Tea is an agricultural product of the leaves, leaf buds, and internodes of various cultivars and sub-varieties of the Camellia sinensis plant, processed and vulcanized using various methods. Tea is a main beverage in Iranian food basket so should be free from toxic elements such as pesticides residue. There is no data bank on the residue of pesticides in the consumed black tea in Iran. The present study is the first attempt for monitoring of 25 pesticide residues from different chemical groups in tea samples obtained from local markets in Tehran, I.R. Iran during the period 2011. A reliable and accurate method based on spiked calibration curve and QuEChERS sample preparation was developed for determination of pesticide residues in tea by gas chromatography–mass spectrometry (GC/MS. The using of spiked calibration standards for constructing the calibration curve substantially reduced adverse matrix-related effects and negative recovery affected by GCB on pesticides. The recovery of pesticides at 3 concentration levels (n = 3 was in range of 81.4 - 99.4%. The method was proved to be repeatable with RSDr lower than 20%. The limits of quantification for all pesticides were ≤20 ng/g. 53 samples from 17 imported and manufactured brand were analyzed. Detectable pesticides residues were found in 28.3% (15 samples of the samples. All of the positive samples were contaminated with unregulated pesticides (Endosulfan Sulfate or Bifenthrin which are established by ISIRI. None of the samples had contamination higher than maximum residue limit set by EU and India.

  18. Treatment Method for Fermi Barrel Sodium Metal Residues

    Energy Technology Data Exchange (ETDEWEB)

    Steven R. Sherman; Collin J. Knight

    2005-06-01

    Fermi barrels are 55-gallon drums that once contained bulk sodium metal from the shutdown Fermi 1 breeder reactor facility, and now contain residual sodium metal and other sodium/air reaction products. This report provides a residual sodium treatment method and proposed quality assurance steps that will ensure that all residual sodium is deactivated and removed from the Fermi barrels before disposal. The treatment method is the application of humidified carbon dioxide to the residual sodium followed by a water wash. The experimental application of the treatment method to six Fermi barrels is discussed, and recommendations are provided for further testing and evaluation of the method. Though more testing would allow for a greater refinement of the treatment technique, enough data has been gathered from the tests already performed to prove that 100% compliance with stated waste criteria can be achieved.

  19. Convergence of a residual based artificial viscosity finite element method

    KAUST Repository

    Nazarov, Murtazo

    2013-02-01

    We present a residual based artificial viscosity finite element method to solve conservation laws. The Galerkin approximation is stabilized by only residual based artificial viscosity, without any least-squares, SUPG, or streamline diffusion terms. We prove convergence of the method, applied to a scalar conservation law in two space dimensions, toward an unique entropy solution for implicit time stepping schemes. © 2012 Elsevier B.V. All rights reserved.

  20. Industrial chimney monitoring - contemporary methods

    Science.gov (United States)

    Kaszowska, Olga; Gruchlik, Piotr; Mika, Wiesław

    2018-04-01

    The paper presents knowledge acquired during the monitoring of a flue-gas stack, performed as part of technical and scientific surveillance of mining activity and its impact on industrial objects. The chimney is located in an area impacted by mining activity since the 1970s, from a coal mine which is no longer in existence. In the period of 2013-16, this area was subject to mining carried out by a mining entrepreneur who currently holds a license to excavate hard coal. Periodic measurements of the deflection of the 113-meter chimney are performed using conventional geodetic methods. The GIG used 3 methods to observe the stack: landbased 3D laser scanning, continuous deflection monitoring with a laser sensor, and drone-based visual inspections. The drone offered the possibility to closely inspect the upper sections of the flue-gas stack, which are difficult to see from the ground level.

  1. Testing the efficiency of extraction of incurred residues from soil with optimized multi-residue method.

    Science.gov (United States)

    Suszter, Gabriella K; Ambrus, Árpád

    2017-08-03

    The reproducibility of extraction of residues from spiked soil samples and from soils containing incurred residues was tested with 14 C-labeled test compounds of different physical-chemical properties. Nearly 100% of the compounds added to the sample before extraction could be recovered with an average reproducibility relative standard deviation (CV) of 5.4%. The additional steps of the determination process (cleanup, evaporation, etc.) contributed to the major part of the variability of the results (CV = 10-20%). The incurred residues were most efficiently extracted with acetone for 30 min followed by the mixture of acetone/ethyl acetate 1:1 for additional 30 min. However, they could only be recovered at various extent (64-90% of total residues), underlying the importance of testing the efficiency of extraction. The residues were identified and quantified by gas chromatography applying thermionic detector. The performance parameters of the method complied with the international method validation guidelines, and they proved to be robust and suitable for determination of pesticide residues in soils of widely different physical-chemical properties.

  2. Residual Stress Analysis Based on Acoustic and Optical Methods

    Directory of Open Access Journals (Sweden)

    Sanichiro Yoshida

    2016-02-01

    Full Text Available Co-application of acoustoelasticity and optical interferometry to residual stress analysis is discussed. The underlying idea is to combine the advantages of both methods. Acoustoelasticity is capable of evaluating a residual stress absolutely but it is a single point measurement. Optical interferometry is able to measure deformation yielding two-dimensional, full-field data, but it is not suitable for absolute evaluation of residual stresses. By theoretically relating the deformation data to residual stresses, and calibrating it with absolute residual stress evaluated at a reference point, it is possible to measure residual stresses quantitatively, nondestructively and two-dimensionally. The feasibility of the idea has been tested with a butt-jointed dissimilar plate specimen. A steel plate 18.5 mm wide, 50 mm long and 3.37 mm thick is braze-jointed to a cemented carbide plate of the same dimension along the 18.5 mm-side. Acoustoelasticity evaluates the elastic modulus at reference points via acoustic velocity measurement. A tensile load is applied to the specimen at a constant pulling rate in a stress range substantially lower than the yield stress. Optical interferometry measures the resulting acceleration field. Based on the theory of harmonic oscillation, the acceleration field is correlated to compressive and tensile residual stresses qualitatively. The acoustic and optical results show reasonable agreement in the compressive and tensile residual stresses, indicating the feasibility of the idea.

  3. A Novel Residual Frequency Estimation Method for GNSS Receivers.

    Science.gov (United States)

    Nguyen, Tu Thi-Thanh; La, Vinh The; Ta, Tung Hai

    2018-01-04

    In Global Navigation Satellite System (GNSS) receivers, residual frequency estimation methods are traditionally applied in the synchronization block to reduce the transient time from acquisition to tracking, or they are used within the frequency estimator to improve its accuracy in open-loop architectures. There are several disadvantages in the current estimation methods, including sensitivity to noise and wide search space size. This paper proposes a new residual frequency estimation method depending on differential processing. Although the complexity of the proposed method is higher than the one of traditional methods, it can lead to more accurate estimates, without increasing the size of the search space.

  4. Diagnosis of Plasma Cell Dyscrasias and Monitoring of Minimal Residual Disease by Multiparametric Flow Cytometry

    Science.gov (United States)

    Soh, Kah Teong; Tario, Joseph D.; Wallace, Paul K.

    2018-01-01

    Synopsis Plasma cell dyscrasia (PCD) is a heterogeneous disease which has seen a tremendous change in outcomes due to improved therapies. Over the last few decades, multiparametric flow cytometry has played an important role in the detection and monitoring of PCDs. Flow cytometry is a high sensitivity assay for early detection of minimal residual disease (MRD) that correlates well with progression-free survival and overall survival. Before flow cytometry can be effectively implemented in the clinical setting sample preparation, panel configuration, analysis, and gating strategies must be optimized to ensure accurate results. Current consensus methods and reporting guidelines for MRD testing are discussed. PMID:29128071

  5. Application of the contour method to validate residual stress predictions

    International Nuclear Information System (INIS)

    Welding is the most widespread method employed to join metallic components in nuclear power plants. This is an aggressive process that introduces complex three-dimensional residual stresses of substantial magnitude into engineering components. For safety-critical applications it can be of crucial importance to have an accurate characterisation of the residual stress field present in order to assess plant lifetime and risk of failure. Finite element modelling approaches are being increasingly employed by engineers to predict welding residual stresses. However, such predictions are challenging owing to the innate complexity of the welding process and can give highly variable results. Therefore, it is always desirable to validate residual stress predictions by experimental data. This paper illustrates how the contour method of measuring residual stress can be applied to various weldments in order to provide high quality experimental data. The contour method results are compared with data obtained by other well-established residual stress measurement techniques such as neutron diffraction and slitting methods and show a very satisfactory correlation. (author)

  6. Detection of residues antibiotics in food using a microbiological method

    International Nuclear Information System (INIS)

    Ben Ali, Ahmed

    2007-01-01

    Antibiotics are effective therapeutic agents because of their property of selective bacterial toxicity which helps controlling infections. Animals, just like humans, can be treated with antibiotics. This use of antibiotics can lead to the development of resistance. Resistant strains may cause severe infections in humans and animals. In addition, antibiotic residues might represent a problem for human health. Our objective is to develop a microbiological method for the detection of antibiotic residues in poultry(muscle, liver,...). For this purpose, antibiotic sensitive bacteria and selective agar media were used. An inhibition growth zone surrounds each of the food samples containing antibiotic residues after a prescribed incubation time. (Author). 23 refs

  7. FPGA Implementation of Uniform Random Number based on Residue Method

    Directory of Open Access Journals (Sweden)

    Zulfikar .

    2014-04-01

    Full Text Available This paper presents the implementation and comparisons of uniform random number on Field Programable Gate Array (FPGA. Uniform random numbers are generated based on residue method. The circuit of generating uniform random number is presented in general view. The circuit is constructed from a multiplexer, a multiplier, buffers and some basic gates. FPGA implementation of the designed circuit has been done into various Xilinx chips. Simulation results are viewed clearly in the paper. Random numbers are generated based on different parameters. Comparisons upon occupied area and maximum frequency from different Xilinx chip are examined. Virtex 7 is the fastest chip and Virtex 4 is the best choice in terms of occupied area. Finally, Uniform random numbers have been generated successfully on FPGA using residue method.Keywords: FPGA implementation, random number, uniform random number, residue method, Xilinx chips

  8. Monitoring the extraction of additives and additive degradation products from polymer packaging into solutions by multi-residue method including solid phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis.

    Science.gov (United States)

    Pouech, Charlène; Lafay, Florent; Wiest, Laure; Baudot, Robert; Léonard, Didier; Cren-Olivé, Cécile

    2014-02-01

    The use of polymer materials in industry for product packaging is increasing. The presence of additives in the polymer matrix enables the modification or improvement of the properties and performance of the polymer, but these industries are concerned regarding the extractability of these additives. The quantification of these additives is particularly challenging because of the presence of these substances as contaminants in all the analytical equipment and the diversity of their physicochemical properties. In this context, a multi-residue analytical method was developed for the trace analysis of the twenty main additives (and their degradation products) authorized in plastic products such as pharmaceutical packaging (e.g., antioxidants, release agents, and light absorbers). This analytical method consisted of a solid phase extraction (SPE) followed by an analysis using ultra-high performance liquid chromatography coupled to a tandem mass spectrometer (UHPLC-MS/MS). A comparison of two ionization interfaces and the optimization of the extraction procedure were discussed. The influence of the quality of the solvent type (distilled versus not distilled) and the nature of the SPE cartridges (Polypropylene versus Teflon(®)) were demonstrated. The optimized method exhibited a quantification limit lower than 20 ng mL(-1) and recoveries between 70 % and 120 % for all compounds. Finally, the method was validated according to the ICH directive and was subsequently applied to the extraction of polymers under different pH conditions and storage temperatures. To the best of our knowledge, this study presents the first methodology allowing the simultaneous quantification of 24 additives at low ng mL(-1).

  9. Monitoring Plan for Pesticide Residues in Fruits and Vegetables

    International Nuclear Information System (INIS)

    2013-01-01

    The power point presentation has as objective of the study is monitoring in fruits and vegetables species, chemical submit higher risk for the consumer and for the purpose of establishing an order of priority in the products sampled

  10. Wireless device monitoring systems and monitoring devices, and associated methods

    Science.gov (United States)

    McCown, Steven H; Derr, Kurt W; Rohde, Kenneth W

    2014-05-27

    Wireless device monitoring systems and monitoring devices include a communications module for receiving wireless communications of a wireless device. Processing circuitry is coupled with the communications module and configured to process the wireless communications to determine whether the wireless device is authorized or unauthorized to be present at the monitored area based on identification information of the wireless device. Methods of monitoring for the presence and identity of wireless devices are also provided.

  11. Monitoring and Auditing Residual Information on the User’s Computer

    Directory of Open Access Journals (Sweden)

    Vladlena Sergeevna Oladk

    2015-06-01

    Full Text Available This paper considers the problem of violation of information security components such as confidentiality and availability in the event of a computer user's residual information. Analyze the requirements of regulators and mechanisms to be applied in the organization to monitor the residual information or its destruction.Approach to monitoring and auditing residual information on the user's computer, which allows monitoring the residual information in certain areas proposed. Approach allows us to identify the detected information and rank it according to the degree of criticality, as well as calculate the risk of leakage and its potential to develop recommendations aimed at its reduction. The proposed approach is formally described and automated in a software system.

  12. Residual-based model diagnosis methods for mixture cure models.

    Science.gov (United States)

    Peng, Yingwei; Taylor, Jeremy M G

    2017-06-01

    Model diagnosis, an important issue in statistical modeling, has not yet been addressed adequately for cure models. We focus on mixture cure models in this work and propose some residual-based methods to examine the fit of the mixture cure model, particularly the fit of the latency part of the mixture cure model. The new methods extend the classical residual-based methods to the mixture cure model. Numerical work shows that the proposed methods are capable of detecting lack-of-fit of a mixture cure model, particularly in the latency part, such as outliers, improper covariate functional form, or nonproportionality in hazards if the proportional hazards assumption is employed in the latency part. The methods are illustrated with two real data sets that were previously analyzed with mixture cure models. © 2016, The International Biometric Society.

  13. Rapid multi-residue method for the determination of pesticide ...

    African Journals Online (AJOL)

    Exposure to pesticides can represent a potential risk to humans. Agricultural workers are at risk of chronic toxicity. Hence, the evaluation of pesticide residues in their blood gives an indication about the extent of exposure and help in assessing adverse health effects. The aim of our study was to develop analytical method for ...

  14. Smoothing-Norm Preconditioning for Regularizing Minimum-Residual Methods

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Toke Koldborg

    2006-01-01

    take into account a smoothing norm for the solution. This technique is well established for CGLS, but it does not immediately carry over to minimum-residual methods when the smoothing norm is a seminorm or a Sobolev norm. We develop a new technique which works for any smoothing norm of the form $\\|L...

  15. Ceramic residue for producing cements, method for the production thereof, and cements containing same

    OpenAIRE

    Sánchez de Rojas, María Isabel; Frías, Moisés; Asensio, Eloy; Medina Martínez, César

    2014-01-01

    [EN] The invention relates to a ceramic residue produced from construction and demolition residues, as a puzzolanic component of cements. The invention also relates to a method for producing said ceramic residues and to another method of producing cements using said residues. This type of residue is collected in recycling plants, where it is managed. This invention facilitates a potential commercial launch.

  16. Improving Neuromuscular Monitoring and Reducing Residual Neuromuscular Blockade With E-Learning

    DEFF Research Database (Denmark)

    Thomsen, Jakob Louis Demant; Mathiesen, Ole; Hägi-Pedersen, Daniel

    2017-01-01

    and an increased risk of respiratory complications. Use of an objective neuromuscular monitoring device may prevent residual block. Despite this, many anesthetists refrain from using the device. Efforts to increase the use of objective monitoring are time consuming and require the presence of expert personnel....... A neuromuscular monitoring e-learning module might support consistent use of neuromuscular monitoring devices. OBJECTIVE: The aim of the study is to assess the effect of a neuromuscular monitoring e-learning module on anesthesia staff's use of objective neuromuscular monitoring and the incidence of residual...... departments in the Zealand Region of Denmark are included, and data from all patients receiving a muscle relaxant are collected from the anesthesia information management system MetaVision. We will assess the effect of the module on all levels of potential effect: staff's knowledge and skills, patient care...

  17. Residual capacity estimation of bridges using structural health monitoring data

    Science.gov (United States)

    Baghaei, Reza; Feng, Maria Q.; Torbol, Marco

    2011-04-01

    In this study, a vibration-based procedure for residual capacity estimation of bridges after damaging earthquake events is proposed. The procedure starts with estimation of collapse capacity of the intact bridge using incremental dynamic analysis (IDA) curves. The collapse capacity is defined as the median intensity level of the earthquakes that cause global or local collapse within the structure. A database of post-earthquake modal properties is created by calculating the analytical modal properties of the bridge after each nonlinear response history analysis performed for generation IDA curves. After the damaging event, experimental modal properties of the bridge are identified from vibration measurements of the bridge. These properties along with the modal properties database are used to find ground motionintensity pairs that can drive nonlinear FE model of the structure to the current damage state of the bridge. The IDA curves corresponding to the damaged FE model of the bridge are subsequently used to estimate amount of loss in collapse capacity of the damaged structure. Estimated loss in capacity of the bridge besides the bridge-site-specific seismic hazard curves are used to update the functionality status of the bridge. Proposed procedure is applied to experimental data from a large-scale shake table test on a quarter-scale model of a short-span reinforced concrete bridge. The bridge was subjected to a series of earthquake ground motions introducing progressive seismic damage to the bridge which finally led to the failure of one of the bents. Residual collapse capacity and functionality status of the bridge are updated at different stages of the experiment using the proposed procedure.

  18. Prediction of residual stress using explicit finite element method

    Directory of Open Access Journals (Sweden)

    W.A. Siswanto

    2015-12-01

    Full Text Available This paper presents the residual stress behaviour under various values of friction coefficients and scratching displacement amplitudes. The investigation is based on numerical solution using explicit finite element method in quasi-static condition. Two different aeroengine materials, i.e. Super CMV (Cr-Mo-V and Titanium alloys (Ti-6Al-4V, are examined. The usage of FEM analysis in plate under normal contact is validated with Hertzian theoretical solution in terms of contact pressure distributions. The residual stress distributions along with normal and shear stresses on elastic and plastic regimes of the materials are studied for a simple cylinder-on-flat contact configuration model subjected to normal loading, scratching and followed by unloading. The investigated friction coefficients are 0.3, 0.6 and 0.9, while scratching displacement amplitudes are 0.05 mm, 0.10 mm and 0.20 mm respectively. It is found that friction coefficient of 0.6 results in higher residual stress for both materials. Meanwhile, the predicted residual stress is proportional to the scratching displacement amplitude, higher displacement amplitude, resulting in higher residual stress. It is found that less residual stress is predicted on Super CMV material compared to Ti-6Al-4V material because of its high yield stress and ultimate strength. Super CMV material with friction coefficient of 0.3 and scratching displacement amplitude of 0.10 mm is recommended to be used in contact engineering applications due to its minimum possibility of fatigue.

  19. Analysis Method for Pesticides Residues by GC/MS in Lebanese Apple

    International Nuclear Information System (INIS)

    Jaber, F.; Al Iskandarani, M.

    2008-01-01

    The apple's crop can be affected by many pests during the growing season, which requires careful monitoring. Both apple fruit and apple tree need to be treated by pesticides in order to protect them from pests. Such treatment often leads to the accumulation of stable pesticides inside the fruit. The local market provides a large variety of pesticides allowing farmers to use more than one active substance in order to protect their crop, often without proper advice. Monitoring pesticides on apples and other agricultural crops is the best way to protect consumers health from the hazards of pesticides residues. The development of new, rapid and effective method to analyze the multi pesticides residues at trace levels in apple samples is essential. This work describes the extraction procedure and the analytical method developed to detect the pesticide residues using the gas-chromatographic-mass spectrometric approach (GC-MS). The developed method was successfully applied to analyze apple samples collected from different Lebanese markets for a one year period in order to monitor the presence of pesticides and their stability in apple fruits during storage. (author)

  20. Proficiency test on the determination of pesticide residues in grapes with multi-residue methods.

    Science.gov (United States)

    Dehouck, Pieter; Grimalt, Susana; Dabrio, Marta; Cordeiro, Fernando; Fiamegos, Yiannis; Robouch, Piotr; Fernández-Alba, Amadeo R; de la Calle, Beatriz

    2015-05-22

    This manuscript presents the results of the International Measurement Evaluation Programme 37 (IMEP-37) study, a proficiency test (PT) which was organised to assess the world-wide performance of food control laboratories on the determination of pesticide residues in grapes. This PT supports the implementation of Regulation (EC) No 396/2005 on maximum residue levels of pesticides in or on food and feed of plant and animal origin. Eighty-one participants reported results, forty from EU Member States and forty-one from outside the EU. The test item was a grape sample spiked with 20 selected pesticides. The results of the participants were rated with z- and zeta (ζ-) scores in accordance with ISO 13528 and ISO 17043. The standard deviation for the proficiency assessment, σˆ, of this PT was set at 25% for the 20 measured pesticides based on previous experience with similar measurands. The results reported to IMEP-37 showed that the participants performed satisfactorily, ranging from 81% (carbendazim) to 97% (azoxystrobin, penconazole, pyrimethanil) of the participating laboratories. However, only 30% of the participants managed to analyze all pesticides satisfactorily. Overall, the performance of the participants in this PT was good but there is room for improvement in the development of multi-residue methods for the simultaneous analysis of a large number of pesticides with an increased accuracy. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Analytical Methods for Detonation Residues of Insensitive Munitions

    Science.gov (United States)

    Walsh, Marianne E.

    2016-01-01

    Analytical methods are described for the analysis of post-detonation residues from insensitive munitions. Standard methods were verified or modified to obtain the mass of residues deposited per round. In addition, a rapid chromatographic separation was developed and used to measure the mass of NTO (3-nitro-1,2,4-triazol-5-one), NQ (nitroguanidine) and DNAN (2,4-dinitroanisole). The HILIC (hydrophilic-interaction chromatography) separation described here uses a trifunctionally-bonded amide phase to retain the polar analytes. The eluent is 75/25 v/v acetonitrile/water acidified with acetic acid, which is also suitable for LC/MS applications. Analytical runtime was three minutes. Solid phase extraction and LC/MS conditions are also described.

  2. Monitoring of Pesticide Residues in Commonly Used Fruits and Vegetables in Kuwait.

    Science.gov (United States)

    Jallow, Mustapha F A; Awadh, Dawood G; Albaho, Mohammed S; Devi, Vimala Y; Ahmad, Nisar

    2017-07-25

    The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers. The aim of this study was to assess the level of pesticide residues in commonly consumed fruits and vegetables in Kuwait. A total of 150 samples of different fresh vegetables and fruits were analyzed for the presence of 34 pesticides using the quick easy cheap effective rugged and safe (QuEChERS) multi-residue extraction, followed by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC - MS / MS). Pesticide residues above the maximum residue limits (MRL) were detected in 21% of the samples and 79% of the samples had no residues of the pesticides surveyed or contained residues below the MRL. Multiple residues were present in 40% of the samples with two to four pesticides, and four samples were contaminated with more than four pesticide residues. Of the pesticides investigated, 16 were detected, of which imidacloprid, deltamethrin, cypermethrin, malathion, acetamiprid, monocrotophos, chlorpyrifos-methyl, and diazinon exceeded their MRLs. Aldrin, an organochlorine pesticide, was detected in one apple sample, with residues below the MRL. The results indicate the occurrence of pesticide residues in commonly consumed fruits and vegetables in Kuwait, and pointed to an urgent need to develop comprehensive intervention measures to reduce the potential health risk to consumers. The need for the regular monitoring of pesticide residues and the sensitization of farmers to better pesticide safety practices, especially the need to adhere to recommended pre-harvest intervals is recommended.

  3. Monitoring of Pesticide Residues in Commonly Used Fruits and Vegetables in Kuwait

    Directory of Open Access Journals (Sweden)

    Mustapha F. A. Jallow

    2017-07-01

    Full Text Available The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers. The aim of this study was to assess the level of pesticide residues in commonly consumed fruits and vegetables in Kuwait. A total of 150 samples of different fresh vegetables and fruits were analyzed for the presence of 34 pesticides using the quick easy cheap effective rugged and safe (QuEChERS multi-residue extraction, followed by gas chromatography-mass spectrometry (GC-MS or liquid chromatography-tandem mass spectrometry (LC-MS/MS. Pesticide residues above the maximum residue limits (MRL were detected in 21% of the samples and 79% of the samples had no residues of the pesticides surveyed or contained residues below the MRL. Multiple residues were present in 40% of the samples with two to four pesticides, and four samples were contaminated with more than four pesticide residues. Of the pesticides investigated, 16 were detected, of which imidacloprid, deltamethrin, cypermethrin, malathion, acetamiprid, monocrotophos, chlorpyrifos-methyl, and diazinon exceeded their MRLs. Aldrin, an organochlorine pesticide, was detected in one apple sample, with residues below the MRL. The results indicate the occurrence of pesticide residues in commonly consumed fruits and vegetables in Kuwait, and pointed to an urgent need to develop comprehensive intervention measures to reduce the potential health risk to consumers. The need for the regular monitoring of pesticide residues and the sensitization of farmers to better pesticide safety practices, especially the need to adhere to recommended pre-harvest intervals is recommended.

  4. Monitoring of multiple pesticide residues in some fruits in Karachi, Pakistan

    International Nuclear Information System (INIS)

    Parveen, Z.; Riazuddin, A.; Iqbal, S.; Bhutto, M.A.; Khuhro, M.I.

    2011-01-01

    One hundred and twenty samples of different fruits including apple, apricot, persimmon, chiku, citrus, grapes, guava, mango, papaya, peach, plum and pomegranate procured from different selling points of Karachi, Pakistan during 2008-2009, were analyzed for monitoring of multiple pesticide residues using GC/FID and HPLC/UV. The results showed exceeding level of contamination. On an average 62.5% samples contained residues of pesticides while 22% samples exceeded the maximum residue limits (MRLs) as given by FAO/WHO (Anon., 2000). (author)

  5. Monitoring Antibiotic Residues and Corresponding Antibiotic Resistance Genes in an Agroecosystem

    Directory of Open Access Journals (Sweden)

    Yasser M. Awad

    2015-01-01

    Full Text Available Antibiotic resistance genes (ARGs have been commonly reported due to the overuse worldwide of antibiotics. Antibiotic overuse disturbs the environment and threatens public human health. The objective of this study was to measure the residual concentrations of veterinary antibiotics in the tetracycline group (TCs, including tetracycline (TC and chlortetracycline (CTC, as well as those in the sulfonamide group (SAs, including sulfamethazine (SMT, sulfamethoxazole (SMX, and sulfathiazole (STZ. We also isolated the corresponding ARGs in the agroecosystem. Four sediment samples and two rice paddy soil samples were collected from sites near a swine composting facility along the Naerincheon River in Hongcheon, Korea. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS was employed with a solid-phase extraction method to measure the concentration of each antibiotic. ARGs were identified by the qualitative polymerase chain-reaction using synthetic primers. SAs and their corresponding ARGs were highly detected in sediment samples whereas TCs were not detected except for sediments sample #1. ARGs for TCs and SAs were detected in rice paddy soils, while ARGs for TCs were only found in sediment #2 and #4. Continuous monitoring of antibiotic residue and its comprehensive impact on the environment is needed to ensure environmental health.

  6. Validation of a residue method to determine pesticide residues in cucumber by using nuclear techniques

    International Nuclear Information System (INIS)

    Baysoyu, D.; Tiryaki, O.; Secer, E.; Aydin, G.

    2009-01-01

    In this study, a multi-residue method using ethyl acetate for extraction and gel permeation chromatography for clean-up was validated to determine chlorpyrifos, malathion and dichlorvos in cucumber by gas chromatography. For this purpose, homogenized cucumber samples were fortified with pesticides at 0.02 0.2, 0.8 and 1 mg/kg levels. The efficiency and repeatability of the method in extraction and cleanup steps were performed using 1 4C-carbaryl by radioisotope tracer technique. 1 4C-carbaryl recoveries after the extraction and cleanup steps were between 92.63-111.73 % with a repeatability of 4.85% (CV) and 74.83-102.22 % with a repeatability of 7.19% (CV), respectively. The homogeneity of analytical samples and the stability of pesticides during homogenization were determined using radio tracer technique and chromatographic methods, respectively.

  7. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    Science.gov (United States)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  8. A review of experimental methods for determining residual creep life

    International Nuclear Information System (INIS)

    Bolton, C.J.

    1977-11-01

    Experimental methods available for determining how much creep life remains at a particular time in the high temperature service of a component are reviewed. After a brief consideration of the limitations of stress rupture extrapolation techniques, the application of post-exposure creep testing is considered. Ways of assessing the effect of microstructural degradation on residual life are then reviewed. It is pointed out that while this type of work will be useful for certain materials, there are other materials in which 'mechanical damage' such as cavitation will be more important. Cavitation measurement techniques are therefore reviewed. The report ends with a brief consideration of the use of crack growth measurements in assessing the residual life of cracked components. (author)

  9. Monitoring Residual Chlorine Decay and Coliform Contamination in ...

    African Journals Online (AJOL)

    Michael Horsfall

    hours) full with Vim (calcium hypochlorite, home detergent) cleaned thoroughly with distilled water and allowed to dry. All chlorine measurements were by using the N, N-diethyl-p-phenylenediamine(DPD) colorimetric method with a colour comparator. Measurement time intervals were initially at 5 minute, then 10 minute and ...

  10. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  11. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Peters, David Alberg

    2008-01-01

    and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...

  12. Monitoring method call sequences using annotations

    NARCIS (Netherlands)

    B. Nobakht (Behrooz); F.S. de Boer (Frank); M.M. Bonsangue (Marcello); C.P.T. de Gouw (Stijn); M.M. Jaghouri (MohammadMahdi)

    2014-01-01

    htmlabstractIn this paper we introduce JMSeq, a Java-based tool for monitoring sequences of method calls. JMSeq provides a simple but expressive language to specify the observables of a Java program in terms of sequences of possibly nested method calls. Similar to many monitoring-oriented

  13. Gamma ray spectroscopy monitoring method and apparatus

    Science.gov (United States)

    Stagg, William R; Policke, Timothy A

    2017-05-16

    The present invention relates generally to the field of gamma ray spectroscopy monitoring and a system for accomplishing same to monitor one or more aspects of various isotope production processes. In one embodiment, the present invention relates to a monitoring system, and method of utilizing same, for monitoring one or more aspects of an isotope production process where the monitoring system comprises: (A) at least one sample cell; (B) at least one measuring port; (C) at least one adjustable collimator device; (D) at least one shutter; and (E) at least one high resolution gamma ray spectrometer.

  14. Environmental DNA from Residual Saliva for Efficient Noninvasive Genetic Monitoring of Brown Bears (Ursus arctos.

    Directory of Open Access Journals (Sweden)

    Rachel E Wheat

    Full Text Available Noninvasive genetic sampling is an important tool in wildlife ecology and management, typically relying on hair snaring or scat sampling techniques, but hair snaring is labor and cost intensive, and scats yield relatively low quality DNA. New approaches utilizing environmental DNA (eDNA may provide supplementary, cost-effective tools for noninvasive genetic sampling. We tested whether eDNA from residual saliva on partially-consumed Pacific salmon (Oncorhynchus spp. carcasses might yield suitable DNA quality for noninvasive monitoring of brown bears (Ursus arctos. We compared the efficiency of monitoring brown bear populations using both fecal DNA and salivary eDNA collected from partially-consumed salmon carcasses in Southeast Alaska. We swabbed a range of tissue types from 156 partially-consumed salmon carcasses from a midseason run of lakeshore-spawning sockeye (O. nerka and a late season run of stream-spawning chum (O. keta salmon in 2014. We also swabbed a total of 272 scats from the same locations. Saliva swabs collected from the braincases of salmon had the best amplification rate, followed by swabs taken from individual bite holes. Saliva collected from salmon carcasses identified unique individuals more quickly and required much less labor to locate than scat samples. Salmon carcass swabbing is a promising method to aid in efficient and affordable monitoring of bear populations, and suggests that the swabbing of food remains or consumed baits from other animals may be an additional cost-effective and valuable tool in the study of the ecology and population biology of many elusive and/or wide-ranging species.

  15. Pesticide residues in selected food commodities: results from the Danish National Pesticide Monitoring Program 1995-1996.

    Science.gov (United States)

    Juhler, R K; Lauridsen, M G; Christensen, M R; Hilbert, G

    1999-01-01

    The paper presents results of analyses of 4182 samples collected from January 1995 to December 1996 for the Danish National Pesticide Monitoring Program. The program basis is a random sample control supplemented with a target control. The objectives of the control are to monitor consumer exposure to health hazards and to enforce national and European Community regulations. The Danish Veterinary and Food Administration is responsible for establishing methods, data manipulation, and evaluation, but actual analyses are performed at 4 regional laboratories. In addition to a description of the Danish National Pesticide Monitoring Program on food, the effects of lowering the reporting limits are discussed. Pesticides included are those in current use as well as chlorinated pesticides like lindane, DDT, and HCB, occurring in food now primarily as a result of environmental contamination. Commodities analyzed are fruits, vegetables, cereals, bran, fish, and animal products such as meat, butter, cheese, fat, and eggs. In fruits and vegetables, residues were detected in 10% of 2515 samples, with higher incidences of detection for foreign commodities. Violation rate was 0.6%. In food of animal origin, low levels of organochlorine pesticides were detected in most fish samples and in more than half of the animal product samples. However, no results exceeding maximum residue limits were found. No residues of organophosphorus pesticides were detected in the 231 meat samples analyzed.

  16. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  17. Moxidectin residues in lamb tissues: Development and validation of analytical method by UHPLC-MS/MS.

    Science.gov (United States)

    Del Bianchi A Cruz, Michelle; Fernandes, Maria A M; de C Braga, Patricia A; Monteiro, Alda L G; Daniel, Daniela; Reyes, Felix G R

    2018-01-01

    The development and validation of a throughput method for the quantitation of moxidectin residues in lamb target tissues (muscle, kidney, liver and fat) was conducted using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). To achieve higher recovery of the analyte from the matrices, a modified QuEChERS method was used for sample preparation. The chromatographic separation was achieved using a Zorbax Eclipse Plus C18 RRHD column with a mobile phase comprising 5mM ammonium formate solution +0.1% formic acid (A) and acetonitrile +0.1% formic acid (B) in a linear gradient program. Method validation was performed based on the Commission Decision 2002/657/EC and VICH GL49. To quantify the analyte, matrix-matched analytical curves were constructed with spiked blank tissues, with a limit of quantitation of 5ngg -1 and limit of detection of 1.5ngg -1 for all matrices. The linearity, decision limit, detection capability accuracy, and inter- and intra-day repeatability of the method are reported. The method was successfully applied to incurred lamb tissue samples (muscle, liver, kidney and fat) in a concentration range from 5 to 200μgkg -1 , which demonstrated its suitability for monitoring moxidectin residues in lamb tissues in health surveillance programs, as well as for pharmacokinetics and residue depletion studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Plant monitoring method and monitoring device, and plant simulator

    International Nuclear Information System (INIS)

    Yamatani, Takao; Namai, Makoto

    1998-01-01

    The present invention provides a method, a device and a plant simulator for automatically displaying the name of monitoring information, on real time, concerning events including a state of alarm generation, a state of operation switch and a state of equipment operation automatically on a trend display which displays monitoring parameters of a nuclear power plant. Namely, upon occurrence of an event of plant, the name of plant monitoring information, as an event to be displayed, marks instead of the names and other necessary information relevant to the events are displayed while being superposed on the trend information. The event information to be displayed while being superposed on the trend information is conducted along with time axis, and the name of the plant monitor information is displayed while being superposed on the time of occurrence of the event on the time axis. According to the display method and device of the present invention, since the names of the plant monitor information are displayed while being superposed on the trend image on real time, an operator can easily understand. As a result, plant monitoring function can be enhanced. (I.S.)

  19. QuEChERS-based method for the determination of carbamate residues in aromatic herbs by UHPLC-MS/MS.

    Science.gov (United States)

    Nantia, Edouard Akono; Moreno-González, David; Manfo, Faustin P T; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2017-02-01

    A new reliable, fast and highly sensitive method based on ultra-high performance liquid chromatography tandem mass spectrometry has been developed and validated for the determination of 28 carbamates in aromatic herbs. A modified QuEChERS-based method was optimized for the extraction of carbamate residues from a wide variety of fresh herbal products. The proposed method allowed recoveries higher than 72%, achieving quantification limits of 2μgkg(-1), therefore below maximum residue limits established for this type of samples. The combination of QuEChERS with UHPLC-MS/MS introduces a high-throughput methodology for the monitoring of these residues in this type of matrices scarcely explored. The analysis of the real samples revealed that several samples sold in the European Union and in the North West region of Cameroon contain pesticides in concentrations below the maximum residue limits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focussed on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  1. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1990-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focused on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two noval nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  2. Comparison of three microbial screening methods for antibiotics using routine monitoring samples

    NARCIS (Netherlands)

    Pikkemaat, M.G.; Rapallini, M.; Oostra, S.; Elferink, J.W.A.

    2009-01-01

    Monitoring large numbers of slaughter animals for the presence of antimicrobial residues is preferably carried out using microbiological screening methods, because of their high cost-effectiveness. An evaluation of the Nouws antibiotic test (NAT) was performed on routine monitoring samples and the

  3. Microbial screening for quinolones residues in cow milk by bio-optical method.

    Science.gov (United States)

    Appicciafuoco, Brunella; Dragone, Roberto; Frazzoli, Chiara; Bolzoni, Giuseppe; Mantovani, Alberto; Ferrini, Anna Maria

    2015-03-15

    The use of antibiotics on lactating cows should be monitored for the possible risk of milk contamination with residues. Accordingly, Maximum Residue Levels (MRLs) are established by the European Commission to guarantee consumers safety. As pointed out by Dec 2002/657/EC, screening is the first step in the strategy for antibiotic residue control, thus playing a key role in the whole control procedure. However, current routine screening methods applied in milk chain still fail to detect residues of quinolones at concentrations of interest. This paper reports the findings of a new bio-optical method for the screening of quinolones residues in bovine milk, based on E. coli ATCC 11303 growth inhibition. The effect of blank and spiked cow milk samples (aliquots equivalents to 0.8%, v/v) is evaluated in Mueller Hinton Broth (MHb) and MHb enriched with MgSO4 2% (MHb-Mg) inoculated with the test strain at the concentration of 10(4)CFU/mL. The presence of quinolones inhibits the cellular growth in MHb, while this effect is neutralized in MHb-Mg allowing both detection and presumptive identification of quinolones. Growth of the test strain is monitored at 37 °C in a Bioscreen C automated system, and Optical Density (OD) at 600 nm is recorded every 10 min after shaking for 10s. Growth curves (OD vs. time) of E. coli ATCC 11303 are assessed in milk samples, with and without quinolones, and their differences in terms of ΔOD (ΔOD600nm=ODMHb-Mg-ODMHb) are calculated. The presence of quinolones is detected by the cellular growth inhibition (OD vs time, none increase in the value OD) and presumptively identified through the increase of the slope of ΔOD600nm curve (ΔOD vs. time), after about 3h of incubation. The detection limit for ciprofloxacin and enrofloxacin is at the level of MRL, for marbofloxacin is at 2-fold the MRL whereas for danofloxacin is at 4-fold the MRL. Although the sensitivity of the method could be further improved and the procedure automated, it is a

  4. Economic methods for the utilisation of logging residues

    Directory of Open Access Journals (Sweden)

    Gałęzia Tomasz

    2016-03-01

    Full Text Available There are several ways of using logging residues, and the two most common ones in the State Forests are wood chip production for energy purposes by mobile machinery and crushing by tractor-powered crushers. In this research, an economy-based approach was used to compare these methods and assess whether chip production is superior to crushing for clearing a felling area. The average revenues from the sale of wood biomass in the form of wood chips and the average costs of crushing in the Pomorze Forest District were analysed for the period from January 2012 until June 2014. Both revenues and costs (such as fuel, operator’s wage, piling costs, depreciation, insurance and garaging costs were extracted from the State Forests’ database using data-mining software.

  5. Identification methods for structural health monitoring

    CERN Document Server

    Papadimitriou, Costas

    2016-01-01

    The papers in this volume provide an introduction to well known and established system identification methods for structural health monitoring and to more advanced, state-of-the-art tools, able to tackle the challenges associated with actual implementation. Starting with an overview on fundamental methods, introductory concepts are provided on the general framework of time and frequency domain, parametric and non-parametric methods, input-output or output only techniques. Cutting edge tools are introduced including, nonlinear system identification methods; Bayesian tools; and advanced modal identification techniques (such as the Kalman and particle filters, the fast Bayesian FFT method). Advanced computational tools for uncertainty quantification are discussed to provide a link between monitoring and structural integrity assessment. In addition, full scale applications and field deployments that illustrate the workings and effectiveness of the introduced monitoring schemes are demonstrated.

  6. Residual stress condition monitoring via sensor fusion in turning of Inconel 718

    OpenAIRE

    Simeone, A.; Segreto, T.; Teti, R.

    2013-01-01

    A multiple sensor monitoring system, equipped with cutting force, acoustic emission and vibration sensing units, was employed in association with advanced procedures for signal analysis, sensor fusion and cognitive decision making for residual stress evaluation in turning of Inconel 718 nickel alloy. Two signal processing and feature extraction methodologies, based respectively on sensory data statistical evaluation and Principal Component Analysis, were applied to the sensor signals generate...

  7. Residual-driven online generalized multiscale finite element methods

    KAUST Repository

    Chung, Eric T.

    2015-09-08

    The construction of local reduced-order models via multiscale basis functions has been an area of active research. In this paper, we propose online multiscale basis functions which are constructed using the offline space and the current residual. Online multiscale basis functions are constructed adaptively in some selected regions based on our error indicators. We derive an error estimator which shows that one needs to have an offline space with certain properties to guarantee that additional online multiscale basis function will decrease the error. This error decrease is independent of physical parameters, such as the contrast and multiple scales in the problem. The offline spaces are constructed using Generalized Multiscale Finite Element Methods (GMsFEM). We show that if one chooses a sufficient number of offline basis functions, one can guarantee that additional online multiscale basis functions will reduce the error independent of contrast. We note that the construction of online basis functions is motivated by the fact that the offline space construction does not take into account distant effects. Using the residual information, we can incorporate the distant information provided the offline approximation satisfies certain properties. In the paper, theoretical and numerical results are presented. Our numerical results show that if the offline space is sufficiently large (in terms of the dimension) such that the coarse space contains all multiscale spectral basis functions that correspond to small eigenvalues, then the error reduction by adding online multiscale basis function is independent of the contrast. We discuss various ways computing online multiscale basis functions which include a use of small dimensional offline spaces.

  8. Anomaly Monitoring Method for Key Components of Satellite

    Directory of Open Access Journals (Sweden)

    Jian Peng

    2014-01-01

    Full Text Available This paper presented a fault diagnosis method for key components of satellite, called Anomaly Monitoring Method (AMM, which is made up of state estimation based on Multivariate State Estimation Techniques (MSET and anomaly detection based on Sequential Probability Ratio Test (SPRT. On the basis of analysis failure of lithium-ion batteries (LIBs, we divided the failure of LIBs into internal failure, external failure, and thermal runaway and selected electrolyte resistance (Re and the charge transfer resistance (Rct as the key parameters of state estimation. Then, through the actual in-orbit telemetry data of the key parameters of LIBs, we obtained the actual residual value (RX and healthy residual value (RL of LIBs based on the state estimation of MSET, and then, through the residual values (RX and RL of LIBs, we detected the anomaly states based on the anomaly detection of SPRT. Lastly, we conducted an example of AMM for LIBs, and, according to the results of AMM, we validated the feasibility and effectiveness of AMM by comparing it with the results of threshold detective method (TDM.

  9. Investigation of antibiotic residues in edible tissues of slaughtered broilers in Maragheh abattoir using FPT method (short comunication

    Directory of Open Access Journals (Sweden)

    Masumeh Abasi

    2016-05-01

    Full Text Available Antibiotic residues in food stuff and their transmission to the consumers have some consequences such as bacterial resistance, allergic reactions, intoxication, carcinogenic effects and disturbing of intestine natural flora. Among microbiologic methods, four plate test (FPT is used to detect antibiotic residues in food stuff, which performs in four culture media with different pH values and test bacteria. The aim of this study was investigation of antibiotic residues in edible tissues of slaughtered broilers in Maragheh abattoir using FPT method. For this reason, 40 slaughtered broilers carcasses in Maragheh abattoir (from 10 different poultry farms were sampled. The sampling was conducted randomly from breast and leg muscles, gizzard as well as liver of each carcass. According to results of current study, 60% of liver samples, 55% of leg samples, 52.5% of breast samples and 52.5% of gizzard samples contained antibiotic residues. Moreover, the amount of antibiotic residues among different samples did not show statistical significance (p>0.05. The highest occurrence of antibiotic residue was found in two flocks (100% and the lowest occurrence was recorded for another two flocks (0%. According to the health hazard of antibiotic residues in foods, continuous monitoring is recommended for edible tissues of broilers.

  10. A method for the determination of residual beta activity in drinking water samples

    Energy Technology Data Exchange (ETDEWEB)

    Idoeta, R. [Dpto. Ingenieria Nuclear y Mecanica de Fluidos, E. T. S. Ingenieria de Bilbao - Universidad del Pais Vasco (UPV/EHU), Alda. Urquijo s/n. 48013 Bilbao (Spain)], E-mail: raquel.idoeta@ehu.es; Herranz, M.; Abelairas, A.; Legarda, F. [Dpto. Ingenieria Nuclear y Mecanica de Fluidos, E. T. S. Ingenieria de Bilbao - Universidad del Pais Vasco (UPV/EHU), Alda. Urquijo s/n. 48013 Bilbao (Spain)

    2007-09-15

    The determination of residual beta activity in drinking water is usually needed in most monitoring programs. In this work a procedure for its determination is described and expressions for the calculations of detection limits and uncertainties are proposed.

  11. A method for the determination of residual beta activity in drinking water samples

    International Nuclear Information System (INIS)

    Idoeta, R.; Herranz, M.; Abelairas, A.; Legarda, F.

    2007-01-01

    The determination of residual beta activity in drinking water is usually needed in most monitoring programs. In this work a procedure for its determination is described and expressions for the calculations of detection limits and uncertainties are proposed

  12. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  13. Applications of geophysical methods to volcano monitoring

    Science.gov (United States)

    Wynn, Jeff; Dzurisin, Daniel; Finn, Carol A.; Kauahikaua, James P.; Lahusen, Richard G.

    2006-01-01

    The array of geophysical technologies used in volcano hazards studies - some developed originally only for volcano monitoring - ranges from satellite remote sensing including InSAR to leveling and EDM surveys, campaign and telemetered GPS networks, electronic tiltmeters and strainmeters, airborne magnetic and electromagnetic surveys, short-period and broadband seismic monitoring, even microphones tuned for infrasound. They include virtually every method used in resource exploration except large-scale seismic reflection. By “geophysical ” we include both active and passive methods as well as geodetic technologies. Volcano monitoring incorporates telemetry to handle high-bandwith cameras and broadband seismometers. Critical geophysical targets include the flux of magma in shallow reservoir and lava-tube systems, changes in active hydrothermal systems, volcanic edifice stability, and lahars. Since the eruption of Mount St. Helens in Washington State in 1980, and the eruption at Pu’u O’o in Hawai’i beginning in 1983 and still continuing, dramatic advances have occurred in monitoring technology such as “crisis GIS” and lahar modeling, InSAR interferograms, as well as gas emission geochemistry sampling, and hazards mapping and eruption predictions. The on-going eruption of Mount St. Helens has led to new monitoring technologies, including advances in broadband Wi-Fi and satellite telemetry as well as new instrumentation. Assessment of the gap between adequate monitoring and threat at the 169 potentially dangerous Holocene volcanoes shows where populations are dangerously exposed to volcanic catastrophes in the United States and its territories . This paper focuses primarily on Hawai’ian volcanoes and the northern Pacific and Cascades volcanoes. The US Geological Survey, the US National Park System, and the University of Utah cooperate in a program to monitor the huge Yellowstone volcanic system, and a separate observatory monitors the restive Long Valley

  14. Detailed monitoring of two biogas plants and mechanical solid-liquid separation of fermentation residues.

    Science.gov (United States)

    Bauer, Alexander; Mayr, Herwig; Hopfner-Sixt, Katharina; Amon, Thomas

    2009-06-01

    The Austrian "green electricity act" (Okostromgesetz) has led to an increase in biogas power plant size and consequently to an increased use of biomass. A biogas power plant with a generating capacity of 500 kW(el) consumes up to 38,000 kg of biomass per day. 260 ha of cropland is required to produce this mass. The high water content of biomass necessitates a high transport volume for energy crops and fermentation residues. The transport and application of fermentation residues to farmland is the last step in this logistic chain. The use of fermentation residues as fertilizer closes the nutrient cycle and is a central element in the efficient use of biomass for power production. Treatment of fermentation residues by separation into liquid and solid phases may be a solution to the transport problem. This paper presents detailed results from the monitoring of two biogas plants and from the analysis of the separation of fermentation residues. Furthermore, two different separator technologies for the separation of fermentation residues of biogas plants were analyzed. The examined biogas plants correspond to the current technological state of the art and have designs developed specifically for the utilization of energy crops. The hydraulic retention time ranged between 45.0 and 83.7 days. The specific methane yields were 0.40-0.43 m(3)N CH(4) per kg VS. The volume loads ranged between 3.69 and 4.00 kg VS/m(3). The degree of degradation was between 77.3% and 82.14%. The screw extractor separator was better suited for biogas slurry separation than the rotary screen separator. The screw extractor separator exhibited a high throughput and good separation efficiency. The efficiency of slurry separation depended on the dry matter content of the fermentation residue. The higher the dry matter content, the higher the proportion of solid phase after separation. In this project, we found that the fermentation residues could be divided into 79.2% fluid phase with a dry matter

  15. Residual stress measurement of welding area by neutron diffraction method

    International Nuclear Information System (INIS)

    Suzuki, Tamaki; Sugiyama, Masaaki; Oikawa, Hatsuhiko; Nose, Tetsuro; Imafuku, Muneyuki; Tomota, Yo; Suzuki, Hiroshi; Moriai, Atsushi

    2010-01-01

    Resistance spot welding technique is extensively applied to join the body steel sheets in the manufacturing process for the automobile industry. It is known that the fatigue crack initiates occasionally inside of the spot-welded zone in this material, which is a serious issue of the fatigue life. Although this phenomenon is supposed to be related to internal residual stress, the actual residual stress distribution inside of the spot-welded zone is not clear up to now. In this study, a neutron diffraction residual stress measurement technique with well-defined sub-mm 3 square gauge volume is applied in order to clarify the internal three dimensional residual stress distribution just below the spot-welded part of the steel sheets. (author)

  16. Three residual income valuation methods and discounted cash flow valuation

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    In this paper we show that the three residual Income models for equity valuation always yield the same value as the Discounted Cash Flow Valuation models. We use three residual income measures: Economic Profit, Economic Value Added (EVA) and Cash Value Added. We also show that economic profit and EVA are different, although Copeland, Koller and Murrin (2000, page 55) say that economic profit is a synonym of EVA. Specifically, we first show that the present value of the Economic Profit discoun...

  17. Comparison of power curve monitoring methods

    Directory of Open Access Journals (Sweden)

    Cambron Philippe

    2017-01-01

    Full Text Available Performance monitoring is an important aspect of operating wind farms. This can be done through the power curve monitoring (PCM of wind turbines (WT. In the past years, important work has been conducted on PCM. Various methodologies have been proposed, each one with interesting results. However, it is difficult to compare these methods because they have been developed using their respective data sets. The objective of this actual work is to compare some of the proposed PCM methods using common data sets. The metric used to compare the PCM methods is the time needed to detect a change in the power curve. Two power curve models will be covered to establish the effect the model type has on the monitoring outcomes. Each model was tested with two control charts. Other methodologies and metrics proposed in the literature for power curve monitoring such as areas under the power curve and the use of statistical copulas have also been covered. Results demonstrate that model-based PCM methods are more reliable at the detecting a performance change than other methodologies and that the effectiveness of the control chart depends on the types of shift observed.

  18. Immunologic methods for monitoring carcinogen exposure

    Science.gov (United States)

    Santella, Regina M.; Perera, Frederica P.; Zhang, Yu J.; Chen, Chen J.; Young, Tie L.

    1993-03-01

    Immunologic methods have been developed for monitoring human exposure to environmental and occupational carcinogens. These methods involve the development of monoclonal and polyclonal antisera which specifically recognize the carcinogens themselves or their DNA or protein adducts. Antisera recognizing the DNA adducts of several polycyclic aromatic hydrocarbon diol epoxides have been used in competitive enzyme-linked immunosorbent assays to monitor adducts in tissue or blood samples. Elevated levels of DNA adducts have been seen in mononuclear cells of smokers and in total white blood cells of foundry and coke oven workers. Environmental exposure to PAH has been measured in individuals living in a highly polluted region of Poland. Antisera recognizing PAH-DNA adducts have also been used in immunohistochemical studies to monitor adducts in specific cells of biopsy samples. The DNA adducts of aflatoxin B1 have been monitored in liver tissue of hepatocellular carcinoma patients in Taiwan. Detectable adducts were seen in 50 - 70% of the patients suggesting that dietary exposure to this carcinogen may be a risk factor for cancer induction. Thus, immunoassays for monitoring exposure to carcinogens are an important tool in epidemiologic studies.

  19. Monitoring volatilization products using Residual Gas Analyzers during MeV ion beam irradiations

    Science.gov (United States)

    Wetteland, C. J.; Kriewaldt, K.; Taylor, L. A.; McSween, H. Y.; Sickafus, K. E.

    2018-03-01

    The use of Residual Gas Analyzers (RGAs) during irradiation experiments can provide valuable information when incorporated into experimental end-stations. The instruments can track the volatilization products of beam-sensitive materials, which may ultimately aid researchers in selecting appropriate flux values for conducting experiments. Furthermore, the type of gaseous species released during an irradiation can be monitored directly, which may lead to new insights into the radiolysis and/or heating mechanisms responsible for gas evolution. A survey of several classes of materials exposed to extremes in particle flux is presented to show how RGA instrumentation can be incorporated to qualitatively assess ion-solid interactions in a variety of fields.

  20. Improving Neuromuscular Monitoring and Reducing Residual Neuromuscular Blockade With E-Learning

    DEFF Research Database (Denmark)

    Thomsen, Jakob Louis Demant; Mathiesen, Ole; Hägi-Pedersen, Daniel

    2017-01-01

    BACKGROUND: Muscle relaxants facilitate endotracheal intubation under general anesthesia and improve surgical conditions. Residual neuromuscular blockade occurs when the patient is still partially paralyzed when awakened after surgery. The condition is associated with subjective discomfort and an......-learning module can increase anesthetists' use of neuromuscular monitoring. TRIAL REGISTRATION: Clinicaltrials.gov NCT02925143; https://clinicaltrials.gov/ct2/show/NCT02925143 (Archived by WebCite® at http://www.webcitation.org/6s50iTV2x)....

  1. Spring Chinook Salmon Interactions Indices and Residual/Precocial Monitoring in the Upper Yakima Basin; Yakima/Klickitat Fisheries Project Monitoring and Evaluation, 2001-2002 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Pearsons, Todd N.; James, Brenda B.; Johnson, Christopher L. (Washington Department of Fish and Wildlife, Olympia, WA)

    2003-05-01

    . 1997). Monitoring ecological interactions will be accomplished using interactions indices. Interactions indices will be used to index the availability of prey and competition for food and space. The tasks described below represent various subject areas of juvenile spring chinook salmon monitoring but are treated together because they can be accomplished using similar methods and are therefore more cost efficient than if treated separately. Three areas of investigation we pursued in this work were: (1) strong interactor monitoring (competition index and prey index), (2) carrying capacity monitoring (microhabitat monitoring); (3) residual and precocial salmon monitoring (abundance). This report is organized into three chapters to represent these three areas of investigation. Data were collected during the summer and fall, 2002 in index sections of the upper Yakima Basin (Figure 1). Hatchery reared spring chinook salmon were first released during the spring of 1999. The monitoring plan for the Yakima/Klickitat Fisheries Project calls for the continued monitoring of the variables covered in this report. All findings in this report should be considered preliminary and subject to further revision as more data and analytical results become available.

  2. Method of monitoring reactor power distribution

    International Nuclear Information System (INIS)

    Sekimizu, Koichi

    1980-01-01

    Purpose: To monitor the power distribution of fuel assemblies at high accuracy in a short time by estimating the relative power distribution based on the amount of neutrons leaking out of the system and converting the same into the absolute power distribution. Method: The relative power distribution is estimated on the amount of neutrons leaking out of the system by the solution of tertiary diffusion equations concerning the counted values from the local power region monitors and the continuous conditions for the current of neutron flux at a position of the local power region. Then, the estimated relative power distribution is converted into the absolute power distribution by using the readings from the local power region monitors. (Horiuchi, T.)

  3. Cl app: android-based application program for monitoring the residue chlorine in water

    Science.gov (United States)

    Intaravanne, Yuttana; Sumriddetchkajorn, Sarun; Porntheeraphat, Supanit; Chaitavon, Kosom; Vuttivong, Sirajit

    2015-07-01

    A farmer usually uses a cheap chemical material called chlorine to destroy the cell structure of unwanted organisms and remove some plant effluents in a baby shrimp farm. A color changing of the reaction between chlorine and chemical indicator is used to monitor the residue chlorine in water before releasing a baby shrimp into a pond. To get rid of the error in color reading, our previous works showed how a smartphone can be functioned as a color reader for estimating the chlorine concentration in water. In this paper, we show the improvement of interior configuration of our prototype and the distribution to several baby shrimp farms. In the future, we plan to make it available worldwide through the online market as well as to develop more application programs for monitoring other chemical substances.

  4. Reduction method for residual stress of welded joint using random vibration

    International Nuclear Information System (INIS)

    Aoki, Shigeru; Nishimura, Tadashi; Hiroi, Tetsumaro

    2005-01-01

    Welded joints are used for construction of many structures. Residual stress is induced near the bead caused by locally given heat. Tensile residual stress on the surface may reduce fatigue strength. In this paper, a new method for reduction of residual stress using vibration during welding is proposed. As vibrational load, random vibration, white noise and filtered white noise are used. Two thin plates are butt-welded. Residual stress is measured with a paralleled beam X-ray diffractometer with scintillation counter after removing quenched scale chemically. It is concluded that tensile residual stress near the bead is reduced by using random vibration during welding

  5. A new spectrophotometric method for determination of residual ...

    African Journals Online (AJOL)

    Polydiallyldimethylammonium chloride (polyDADMAC) is a water-soluble cationic polyelectrolyte used for water treatment. Its residues in treated water are contaminants as they react with chlorine to produce a carcinogenic compound. Commonly-used techniques for quantification of the polycation, such as colloidal and ...

  6. Several methods applied to measuring residual stress in a known specimen

    International Nuclear Information System (INIS)

    Prime, M.B.; Rangaswamy, P.; Daymond, M.R.; Abelin, T.G.

    1998-01-01

    In this study, a beam with a precisely known residual stress distribution provided a unique experimental opportunity. A plastically bent beam was carefully prepared in order to provide a specimen with a known residual stress profile. 21Cr-6Ni-9Mn austenitic stainless steel was obtained as 43 mm square forged stock. Several methods were used to determine the residual stresses, and the results were compared to the known values. Some subtleties of applying the various methods were exposed

  7. Validation of pestice multi residue analysis method on cucumber

    International Nuclear Information System (INIS)

    2011-01-01

    In this study we aimed to validate the method of multi pesticide residue analysis on cucumber. Before real sample injection, system suitability test was performed in gas chromatography (GC). For this purpose, a sensitive pesticide mixture was used for GC-NPD and estimated the performance parameters such as number of effective theoretical plates, resolution factor, asymmetry, tailing and selectivity. It was detected that the system was suitable for calibration and sample injection. Samples were fortified at the level of 0.02, 0.2, 0.8 and 1 mg/kg with mixture of dichlorvos, malathion and chloropyrifos pesticides. In the fortification step 1 4C-carbaryl was also added on homogenized analytical portions to make use of 1 4C labelled pesticides for the determining extraction efficiency. Then the basic analytical process, such as ethyl acetate extraction, filtration, evaporation and cleanup, were performed. The GPC calibration using 1 4C- carbaryl and fortification mixture (dichlorvos, malathion and chloropyrifos) showed that pesticide fraction come through the column between the 8-23 ml fractions. The recovery of 1 4C-carbaryl after the extraction and cleanup step were 92.63-111.73 % and 74.83-102.22 %, respectively. The stability of pesticides during analysis is an important factor. In this study, stability test was performed including matrix effect. Our calculation and t test results showed that above mentioned pesticides were not stabile during sample processing in our laboratory conditions and it was found that sample comminution with dry ice may improve stability. In the other part of the study, 1 4C-chloropyrifos was used to determine homogeneity of analytical portions taken from laboratory samples. Use of 1 4C labelled pesticides allows us for quick quantification analyte, even with out clean-up. The analytical results show that after sample processing with waring blender, analytical portions were homogenous. Sample processing uncertainty depending on quantity of

  8. Measurement of residual stress in textured Al alloy by neutron diffraction method

    International Nuclear Information System (INIS)

    Okido, S.; Hayashi, M.; Tanaka, K.; Akiniwa, Y.; Minakawa, N.; Morii, Y.

    1999-01-01

    Residual stress generated in a shrunken aluminum alloy specimen, which was prepared for the round robin test conducted by VAMAS (Versailles Project on Advanced Materials and Standards) TWA-20 organized for the purpose of standardizing residual stress measurement methods, was evaluated by a neutron diffraction method. The main purpose of the round robin test was to assess the reproducibility of data obtained with the measurement facilities of the participants. The general standard of the Residual Stress Analyzer (RESA) constructed in the Japan Atomic Energy Research Institute was verified from the measured residual strains, which were equivalent to the values calculated by FEM and values measured by the research facilities in North America. Residual stress was calculated from residual strain in three perpendicular directions. The diffraction intensities were dependent on measurement directions since the prepared specimen possessed texture. Diffraction profiles in directions having a weak diffraction intensity caused an inaccurate evaluation of the residual stress. To solve this problem, a new method for evaluating residual stress with respect to diffraction plane dependency of the elastic constant was applied. The diffraction plane giving the highest intensity among 110, 200, and 220 diffraction was used to evaluate the residual strain in each of three directions. The residual strain obtained on the used diffraction plane was converted to the equivalent strain for the defined diffraction plane using the ratio of elastic constants of these two planes. The developed evaluation method achieved highly accurate measurement and remarkable efficiency in the measurement process. (author)

  9. Evaluation of check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1989-01-01

    Check valves are used extensively in nuclear plant safety systems and balance-of-plant (BOP) systems. Their failures have resulted in significant maintenance efforts and, on occasion, have resulted in water hammer, overpressurization of low-pressure systems and damage to flow system components. Consequently, in recent years check valves have received considerable attention by the Nuclear Regulatory Commission (NRC) and the nuclear power industry. Oak Ridge National Laboratory (ORNL) is carrying out a comprehensive two phase aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. As part of the second phase, ORNL is evaluating several developmental and/or commercially available check valve diagnostic monitoring methods; in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. These three methods were found to provide different (and complementary) diagnostic information. The combination of acoustic emission with either ultrasonic or magnetic flux monitoring yields a monitoring system that succeeds in providing sensitivity to detect all major check valve operating conditions. All three methods are still under development and should improve in many respects as a result of further testing and evaluation. 10 refs., 19 figs., 1 tab

  10. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    When a tumor reaches a certain size it can no longer rely on passive perfusion for nutrition. The tumor therefore emits signaling molecules which stimulating surrounding vessels to divide and grow towards the tumor, a process known as angiogenesis. Very little angiogenesis is present in healthy a...... in a transgenic mouse model. The last manuscript presents a new method for in vivo cell labeling. This method could find use in studying the metastatic spread of cancer cells throughout the body.......-angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...... and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...

  11. [Method of detection of residual tissues in recurrent operations on the thyroid gland].

    Science.gov (United States)

    Gostimskiĭ, A V; Romanchishen, A F; Zaĭtseva, I V; Kuznetsova, Iu V

    2014-01-01

    A search of residual tissues is complicated in recurrent operations on the thyroid gland. The Saint-Petersburg Centre of Surgery of the Endocrine System and Oncology developed the method of detection of residual tissues of the thyroid gland with the aim of preoperative chromothyroidolymphography under control of ultrasound. The method consisted of US performance during 15-20 minutes before the operation and an introduction of 1% sterile water solution of methylene blue in revealed residual tissues of the thyroid gland. The volume of injected coloring agent was 0.5-2 ml in the residual tissue volume smaller than 9 cm3 and 2-3 ml injected in case of more than 9 cm3. The residual tissues of the thyroid gland accurately visualized during the following operation. Described method gives the possibility to detect all regions of residual tissues which should be removed and at the same time it shortens a revision and surgery trauma.

  12. Statistical Methods for Environmental Pollution Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Richard O. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    1987-01-01

    The application of statistics to environmental pollution monitoring studies requires a knowledge of statistical analysis methods particularly well suited to pollution data. This book fills that need by providing sampling plans, statistical tests, parameter estimation procedure techniques, and references to pertinent publications. Most of the statistical techniques are relatively simple, and examples, exercises, and case studies are provided to illustrate procedures. The book is logically divided into three parts. Chapters 1, 2, and 3 are introductory chapters. Chapters 4 through 10 discuss field sampling designs and Chapters 11 through 18 deal with a broad range of statistical analysis procedures. Some statistical techniques given here are not commonly seen in statistics book. For example, see methods for handling correlated data (Sections 4.5 and 11.12), for detecting hot spots (Chapter 10), and for estimating a confidence interval for the mean of a lognormal distribution (Section 13.2). Also, Appendix B lists a computer code that estimates and tests for trends over time at one or more monitoring stations using nonparametric methods (Chapters 16 and 17). Unfortunately, some important topics could not be included because of their complexity and the need to limit the length of the book. For example, only brief mention could be made of time series analysis using Box-Jenkins methods and of kriging techniques for estimating spatial and spatial-time patterns of pollution, although multiple references on these topics are provided. Also, no discussion of methods for assessing risks from environmental pollution could be included.

  13. CSmetaPred: a consensus method for prediction of catalytic residues.

    Science.gov (United States)

    Choudhary, Preeti; Kumar, Shailesh; Bachhawat, Anand Kumar; Pandit, Shashi Bhushan

    2017-12-22

    Knowledge of catalytic residues can play an essential role in elucidating mechanistic details of an enzyme. However, experimental identification of catalytic residues is a tedious and time-consuming task, which can be expedited by computational predictions. Despite significant development in active-site prediction methods, one of the remaining issues is ranked positions of putative catalytic residues among all ranked residues. In order to improve ranking of catalytic residues and their prediction accuracy, we have developed a meta-approach based method CSmetaPred. In this approach, residues are ranked based on the mean of normalized residue scores derived from four well-known catalytic residue predictors. The mean residue score of CSmetaPred is combined with predicted pocket information to improve prediction performance in meta-predictor, CSmetaPred_poc. Both meta-predictors are evaluated on two comprehensive benchmark datasets and three legacy datasets using Receiver Operating Characteristic (ROC) and Precision Recall (PR) curves. The visual and quantitative analysis of ROC and PR curves shows that meta-predictors outperform their constituent methods and CSmetaPred_poc is the best of evaluated methods. For instance, on CSAMAC dataset CSmetaPred_poc (CSmetaPred) achieves highest Mean Average Specificity (MAS), a scalar measure for ROC curve, of 0.97 (0.96). Importantly, median predicted rank of catalytic residues is the lowest (best) for CSmetaPred_poc. Considering residues ranked ≤20 classified as true positive in binary classification, CSmetaPred_poc achieves prediction accuracy of 0.94 on CSAMAC dataset. Moreover, on the same dataset CSmetaPred_poc predicts all catalytic residues within top 20 ranks for ~73% of enzymes. Furthermore, benchmarking of prediction on comparative modelled structures showed that models result in better prediction than only sequence based predictions. These analyses suggest that CSmetaPred_poc is able to rank putative catalytic

  14. Toolkit for Monitoring and Evaluation of Indoor Residual Spraying for Visceral Leishmaniasis Control in the Indian Subcontinent: Application and Results

    Directory of Open Access Journals (Sweden)

    M. Mamun Huda

    2011-01-01

    Full Text Available Background. We field tested and validated a newly developed monitoring and evaluation (M&E toolkit for indoor residual spraying to be used by the supervisors at different levels of the national kala-azar elimination programs in Bangladesh, India and Nepal. Methods. Methods included document analysis, in-depth interviews, direct observation of spraying squads, and entomological-chemical assessments (bioassay, susceptibility test, chemical analysis of insecticide residues on sprayed surfaces, vector density measurements at baseline, and three follow-up surveys. Results. We found that the documentation at district offices was fairly complete; important shortcomings included insufficient training of spraying squads and supervisors, deficient spray equipment, poor spraying performance, lack of protective clothing, limited coverage of houses resulting in low bioavailability of the insecticide on sprayed surfaces, and reduced vector susceptibility to DDT in India, which limited the impact on vector densities. Conclusion. The M&E toolkit is a useful instrument for detecting constraints in IRS operations and to trigger timely response.

  15. Current research, regulation, risk, analytical methods and monitoring results for nicarbazin in chicken meat: A perspective review.

    Science.gov (United States)

    Bacila, Danniele Miranda; Feddern, Vivian; Mafra, Luciana Igarashi; Scheuermann, Gerson Neudí; Molognoni, Luciano; Daguer, Heitor

    2017-09-01

    This review presents up-to-date information about current research on nicarbazin, one of the most used anticoccidials in poultry production. The focus is to elucidate regulation concerning nicarbazin, limits for its residues in food, how maximum residue limits in different countries are calculated regarding edible chicken tissues and the possible implications in human health. Analytical methods to extract and quantify this residue, expressed as dinitrocarbanilide (DNC) are presented and discussed, including qualitative screening and quantitative/confirmatory analytical methods. Monitoring results and occurrence of DNC residues in chicken meat are discussed. Additionally, the causes of eventual chicken meat contamination and possible solutions to reduce or eliminate DNC residue in tissues are also presented. The paper concludes with perspectives, the current state of DNC residue analysis and suggestions for future research, especially considering the gap in the study of residue recycling effect due to continuous chicken litter use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Successive monitoring surveys of selected banned and restricted pesticide residues in vegetables from the northwest region of China from 2011 to 2013

    Directory of Open Access Journals (Sweden)

    Yan Yu

    2017-08-01

    Full Text Available Abstract Background A wide range of pesticides is applied for crop protection in vegetable cultivation in China. Regulation of pesticide maximum residue limits (MRLs in vegetables is established but not fully enforced. And pesticide residues in vegetables were not well monitored. This study conducted the monitoring surveys from 2011 to 2013 to investigate the pesticides in vegetables in the northwest region of China. Methods A multi-residue gas chromatography/mass spectrometry method (GC/MS was used in determination of pesticides in vegetable samples. The χ2 test was used to compare the concentration of pesticide residues. Results A total of 32 pesticide residues were detected in 518 samples from 20 types of vegetables in this study. 7.7% of the detected pesticide residues exceeded the MRLs. The percentages of residues that exceeded the MRLs for leafy, melon and fruit, and root vegetables were 11.2%, 5.1%, and 1.6%, respectively. There was no seasonal difference in the proportion of samples that exceeded the MRLs in different vegetables. A total of 84.3% (27/32 pesticides were detected at concentrations that exceeded MRLs. And of the 27 pesticides that exceeded the MRLs, 11 (40.7% were banned for use in agriculture. The most frequently detected pesticides were Malathion (9.4%, Dichlorvos (8.7%, and Dimethoate (8.1%. Conclusion The observed high rate of pesticides detected and high incidence of pesticide detection exceeding their MRLs in the commonly consumed vegetables indicated that the Good Agricultural Practices (GAP may not be well followed. The management of pesticide use and control should be improved. Well-developed training programs should be initiated to improve pesticide application knowledge for farmers.

  17. Reduction method for residual stress of welded joint using harmonic vibrational load

    International Nuclear Information System (INIS)

    Aoki, Shigeru; Nishimura, Tadashi; Hiroi, Tetsumaro; Hirai, Seiji

    2007-01-01

    Welding is widely used for construction of many structures. Since welding is a process using locally given heat, residual stress is generated near the bead. Tensile residual stress degrades fatigue strength. Some reduction methods of residual stress have been presented and, for example, heat treatment and shot peening are practically used. However, those methods need special tools and are time consuming. In this paper, a new method for reduction of residual stress using harmonic vibrational load during welding is proposed. The proposed method is examined experimentally for some conditions. Two thin plates are supported on the supporting device and butt-welded using an automatic CO 2 gas shielded arc welding machine. Residual stress in the direction of the bead is measured by using a paralleled beam X-ray diffractometer with scintillation counter after removing quenched scale chemically. First, the welding of rolled steel for general structure for some excitation frequencies is examined. Specimens are welded along the groove on both sides. For all frequencies, tensile residual stress near the bead is significantly reduced. Second, welding of the specimen made of high tensile strength steel is examined. In this case, tensile residual stress near the bead is also reduced. Finally, the proposed method is examined by an analytical method. An analytical model which consists of mass and preloaded springs with elasto-plastic characteristic is used. Reduction of residual stress is demonstrated using this model

  18. Health monitoring method for composite materials

    Science.gov (United States)

    Watkins, Jr., Kenneth S.; Morris, Shelby J [Hampton, VA

    2011-04-12

    An in-situ method for monitoring the health of a composite component utilizes a condition sensor made of electrically conductive particles dispersed in a polymeric matrix. The sensor is bonded or otherwise formed on the matrix surface of the composite material. Age-related shrinkage of the sensor matrix results in a decrease in the resistivity of the condition sensor. Correlation of measured sensor resistivity with data from aged specimens allows indirect determination of mechanical damage and remaining age of the composite component.

  19. Multiclass methods for the analysis of antibiotic residues in milk by liquid chromatography coupled to mass spectrometry: A review.

    Science.gov (United States)

    Rossi, Rosanna; Saluti, Giorgio; Moretti, Simone; Diamanti, Irene; Giusepponi, Danilo; Galarini, Roberta

    2018-02-01

    Milk is an important and beneficial food from a nutritional point of view, being an indispensable source of high quality proteins. Furthermore, it is a raw material for many dairy products, such as yoghurt, cheese, cream etc. Before reaching consumers, milk goes through production, processing and circulation. Each step involves potentially unsafe factors, such as chemical contamination that can affect milk quality. Antibiotics are widely used in veterinary medicine for dry cow therapy and mastitis treatment in lactating cows, which can cause the presence of antimicrobial residues in milk. In order to ensure consumers' safety, milk is analyzed to make sure that the fixed Maximum Residue Limits (MRLs) for antibiotics are not exceeded. Multiclass methods can monitor more drug classes through a single analysis, so they are faster, less time-consuming and cheaper than traditional methods (single-class); this aspect is particularly important for milk, which is a highly perishable food. Nevertheless, multiclass methods for veterinary drug residues in foodstuffs are real analytical challenges. This article reviews the major multiclass methods published for the determination of antibiotic residues in milk by liquid chromatography coupled to mass spectrometry, with a special focus on sample preparation approaches.

  20. Residual Stress Analysis in Deep Drawn Twinning Induced Plasticity (TWIP) Steels Using Neutron Diffraction Method

    Science.gov (United States)

    Hong, Seokmin; Lee, Junghoon; Lee, Sunghak; Woo, Wanchuck; Kim, Sung-Kyu; Kim, Hyoung Seop

    2014-04-01

    In Twinning Induced Plasticity (TWIP) steels, delayed fracture occurs due to residual stresses induced during deep drawing. In order to investigate the relation between residual stresses and delayed fracture, in the present study, residual stresses of deep drawn TWIP steels (22Mn-0.6C and 18Mn-2Al-0.6C steels) were investigated using the finite element method (FEM) and neutron diffraction measurements. In addition, the delayed fracture properties were examined by dipping tests of cup specimens in the boiled water. In the FEM analysis, the hoop direction residual stress was highly tensile at cup edge, and the delayed fracture was initiated by the separation of hoop direction and propagated in an axial direction. According to the neutron diffraction analysis, residual stresses in 18Mn-2Al-0.6C steel were about half the residual stresses in 22Mn-0.6C steel. From the residual strain measurement using electron back-scatter diffraction, formation of deformation twins caused a lot of grain rotation and local strain at the grain boundaries and twin boundaries. These local residual strains induce residual stress at boundaries. Al addition in TWIP steels restrained the formation of deformation twins and dynamic strain aging, resulting in more homogeneous stress and strain distributions in cup specimens. Thus, in Al-added TWIP steels, residual stress of cup specimen considerably decreased, and delayed fracture resistance was remarkably improved by the addition of Al in TWIP steels.

  1. Plant abnormality monitoring method and device therefor

    International Nuclear Information System (INIS)

    Isobe, Yusuke; Uchida, Shunsuke; Fujimori, Haruo.

    1997-01-01

    The present invention provides a method and a device capable of detecting abnormal symptoms of equipments having failed portions and portions to be repaired and requiring concentrated monitoring in a plant during operation, for example, nuclear power plants, in an early stage without losing reliability. Namely, the abnormality of the plant is judged based on the comparison of plant operation parameters and their allowable values in the method of monitoring plant abnormality. In this case, the allowable values of the plant operation parameters allowed to be changed based on the information on the state of equipments which shows the state of constitutional equipments of the plant. In addition, when a measured plant operation parameter exceeds the allowable value of each of the previously set plant operation parameters, allowable values of other plant operation parameters having relation with the plant operation parameters can be changed. According to the present invention, since the allowable range of the plant operation parameters for the equipments to be repaired and failed equipments can be made narrower than that of ordinary equipments, abnormal symptoms can be detected on the normal side in an early stage. (I.S.)

  2. Radiation area monitor device and method

    Science.gov (United States)

    Vencelj, Matjaz; Stowe, Ashley C.; Petrovic, Toni; Morrell, Jonathan S.; Kosicek, Andrej

    2018-01-30

    A radiation area monitor device/method, utilizing: a radiation sensor; a rotating radiation shield disposed about the radiation sensor, wherein the rotating radiation shield defines one or more ports that are transparent to radiation; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor; and a second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.

  3. The release of 14C-chlorsulfuron bound residue by autoclaving method and its identification

    International Nuclear Information System (INIS)

    Guo Jiangfeng; Sun Jinhe; Ye Qingfu

    1999-01-01

    When individual microorganisms were used to release bound pesticide residues, it was usually not take into full account whether the autoclaving method could lead to the release of bound residues. The soil containing bound 14 C-chlorsulfuron residues was treated with an autoclave in this study. The results reveal that the bound 14 C-chlorsulfuron residue can be released from the soil when treated with the autoclave and the release rate can be remarkably enhanced by adding water into the soil when subjected to such treatment. A TLC analysis showed that the released 14 C-residue was one of the degraded products of 14 C-chlorsulfuron. After derivatization and analysis using the GC-MS, the released 14 C-residue was tentatively identified as 2-amino-4-hydroxyl-6-methyl-1,3,5-triazine

  4. Method for Reduction of Pesticide Residue Levels in Raspberry and Blackcurrant Based on Utilization of Ozone

    Directory of Open Access Journals (Sweden)

    Balawejder Maciej

    2014-12-01

    Full Text Available The method for the reduction of pesticide residues in soft fruits based on utilization of ozone was proposed. The procedure allows for effective reduction of boscalid residues by 38% in raspberries, and about 58% thiram in blackcurrants. Furthermore, it can be used on an industrial scale.

  5. An In Vitro Comparison of Different Diagnostic Methods in Detection of Residual Dentinal Caries

    Directory of Open Access Journals (Sweden)

    Nimet Unlu

    2010-01-01

    Full Text Available The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF device, electronic caries monitor(ECM, and caries detector dye(CDD by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 μm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement for CDD, 0.86 (excellent agreement for ECM, and 0.50 (good agreement for LF. The average interobserver accuracy values were 0.92 (excellent agreement, (0.36 marginal agreement and 0.48 (good agreement, for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection.

  6. Research on measurement of residual stresses of hemispherical lithium hydride by blind-hole method

    Energy Technology Data Exchange (ETDEWEB)

    Bo, Lin, E-mail: linbo@caep.cn [China Academy of Engineering Physics, P.O. Box: 919-71, Mianyang 621900, Sichuan (China); Kaihui, He [China International Nuclear Fusion Energy Program Execution Center, 15B, Fuxing Rd, 100862 Beijing (China); Dongwei, Shan; Weicai, Yang; Yonggang, Chi; Mei, Liu; Jun, Shen [China Academy of Engineering Physics, P.O. Box: 919-71, Mianyang 621900, Sichuan (China)

    2014-04-15

    Highlights: • The residual stresses of sintered and machined lithium hydride of SR40 hyper-hemispherical and SR30 inner hemispherical sample were measured by blind-hole method. • The nearly 45 degrees direction residual stresses of SR40 hyper-hemisphere and SR30 inner hemisphere are the greatest stresses on spherical surface of lithium hydride samples. • The radial residual stress σ{sub r} of SR40 hyper-hemispherical and SR30 inner hemispherical sample is compressive stress and the circumferential residual stress σ{sub t} is tensile stress. - Abstract: The released strains of sintered and machined lithium hydride of SR40 hyper-hemispherical and SR30 inner hemispherical sample could be shown in the measuring process by blind-hole method. The residual stresses of lithium hydride sample were calculated with the formulas of residual stress and released strains. The results show that the nearly 45 degrees direction residual stresses of SR40 hyper-hemisphere and SR30 inner hemisphere are the greatest stresses on spherical surface of lithium hydride samples. The radial residual stress σ{sub r} of SR40 hyper-hemispherical and SR30 inner hemispherical sample is compressive stress and the circumferential residual stress σ{sub t} is tensile stress.

  7. Measurement of capillary permeability in canine heart determined by the tissue injection, residue detection method

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Paaske, W P; Haunsø, S

    1991-01-01

    In previous studies the tissue injection, residue detection method failed to provide results of diffusional capillary permeability comparable to those of other methods. For this reason we reconsidered the kinetic theory and found that it is necessary to take into account the apparent (restricted...... (apparent) interstitial volume of distribution, tev is the mean transit time of the indicator, and klo is the recorded fractional initial washout rate constant. In experiments on open chest dog hearts we examined capillary permeability for 51Cr-EDTA and 99mTc-DTPA with the tissue injection, residue...... detection method and the single injection, residue detection method. Blood flow was measured independently with local 133Xenon washout. D and D' were measured by a true transient diffusion method. We found that the tissue injection, residue detection method gave results for capillary extraction and Pd...

  8. Measurement of capillary permeability in canine heart determined by the tissue injection, residue detection method

    DEFF Research Database (Denmark)

    Svendsen, J H; Paaske, William P; Haunsø, S

    1991-01-01

    detection method and the single injection, residue detection method. Blood flow was measured independently with local 133Xenon washout. D and D' were measured by a true transient diffusion method. We found that the tissue injection, residue detection method gave results for capillary extraction and Pd......In previous studies the tissue injection, residue detection method failed to provide results of diffusional capillary permeability comparable to those of other methods. For this reason we reconsidered the kinetic theory and found that it is necessary to take into account the apparent (restricted...... (apparent) interstitial volume of distribution, tev is the mean transit time of the indicator, and klo is the recorded fractional initial washout rate constant. In experiments on open chest dog hearts we examined capillary permeability for 51Cr-EDTA and 99mTc-DTPA with the tissue injection, residue...

  9. Successive monitoring surveys of selected banned and restricted pesticide residues in vegetables from the northwest region of China from 2011 to 2013.

    Science.gov (United States)

    Yu, Yan; Hu, Senke; Yang, Yuxuan; Zhao, Xiaodan; Xue, Jianjun; Zhang, Jinghua; Gao, Song; Yang, Aimin

    2017-08-02

    A wide range of pesticides is applied for crop protection in vegetable cultivation in China. Regulation of pesticide maximum residue limits (MRLs) in vegetables is established but not fully enforced. And pesticide residues in vegetables were not well monitored. This study conducted the monitoring surveys from 2011 to 2013 to investigate the pesticides in vegetables in the northwest region of China. A multi-residue gas chromatography/mass spectrometry method (GC/MS) was used in determination of pesticides in vegetable samples. The χ 2 test was used to compare the concentration of pesticide residues. A total of 32 pesticide residues were detected in 518 samples from 20 types of vegetables in this study. 7.7% of the detected pesticide residues exceeded the MRLs. The percentages of residues that exceeded the MRLs for leafy, melon and fruit, and root vegetables were 11.2%, 5.1%, and 1.6%, respectively. There was no seasonal difference in the proportion of samples that exceeded the MRLs in different vegetables. A total of 84.3% (27/32) pesticides were detected at concentrations that exceeded MRLs. And of the 27 pesticides that exceeded the MRLs, 11 (40.7%) were banned for use in agriculture. The most frequently detected pesticides were Malathion (9.4%), Dichlorvos (8.7%), and Dimethoate (8.1%). The observed high rate of pesticides detected and high incidence of pesticide detection exceeding their MRLs in the commonly consumed vegetables indicated that the Good Agricultural Practices (GAP) may not be well followed. The management of pesticide use and control should be improved. Well-developed training programs should be initiated to improve pesticide application knowledge for farmers.

  10. Optimization of radiation monitoring methods of environment

    International Nuclear Information System (INIS)

    Bondarkov, M.D.

    2012-01-01

    Full text : Report is devoted to the substantiation of the ways to optimize methods of providing radioecological monitoring (RM) in Ukraine. For this purpose the design features of RM at different levels, the analysis of modern requirements for the RM, the methods for RM ensuring were considered in the dissertation, the use for instrumentation supply of laboratories of new simplified methods, that were developed in this paper, was proposed. This work proposed to strengthen radiobiological component of monitoring, the advantages and disadvantages of the proposed methods were analyzed. The research of the spatial and vertical distribution of radionuclides in soils of the most polluted part of the Chernobyl zone was conducted using the proposed methods. For the first time the parameters of vertical migration of the isotopes 154Eu, 238-240Pu and 241Am in soil profiles of Ch NPP close zone were calculated. The parameters of vertical migration of 90Sr, 137Cs were refined. The calculations of effective environmental and semi-refined periods of above mentioned isotopes for different soil types were conducted, the estimation of dose rates to biota was done, and radioecological characterization of the test sites of the cooling pond was conducted. The features of radioecology of birds, rodents and shrews, bats and amphibians were studied. The dose rates for these species were assessed and their compliance with 103 ICRP Guiding. The species differences in the pollution of wild rodents, insectivores, passerine birds, amphibians and bats on a large amount of factual material were estimated. The investigation of the radioecological contamination of the features of the urbanized landscape was conducted on the example of Pripyat silty. The practical significance of the work is that the developed methods of non radiochemical determination of radiostrontium activity, alpha emitting isotopes of plutonium, which can significantly hasten and facilitate the evaluation of the

  11. Multi-residue method for the confirmation of four avermectin residues in food products of animal origin by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Fengmei; Chen, Junhui; Cheng, Hongyan; Tang, Zhixu; Zhang, Gang; Niu, Zengyuan; Pang, Shiping; Wang, Xiaoru; Lee, Frank Sen-Chun

    2011-05-01

    A confirmatory method was developed for the rapid determination of abamectin, ivermectin, doramectin and eprinomectin residues in various food products of animal origin, such as pork muscle, pork liver, fish and milk. Samples were homogenized, extracted and de-proteinized by acetonitrile, cleaned via two-step cleaning procedure using Bond Elut C(18) SPE columns and then alumina-N cartridges. All the four avermectin residues in different animal-food products were simultaneously separated and determined by ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS) within 3.5 min. Data acquisition under positive ESI-MS/MS was performed by applying multiple reaction monitoring (MRM) for both identification and quantification, and mass spectrometric conditions were optimized to increase selectivity and sensitivity. The matrix-matched calibration curves for different matrices, such as pork muscle, pork liver, fish and milk, were constructed and the interference effect of different sample matrices on the ionization was effectively eliminated. The UPLC-MS/MS method was validated with satisfactory linearity, recovery, precision and stability. Matrix-matched calibration curves of abamectin, ivermectin, doramectin and eprinomectin in four different matrices were linear (r(2)( )≥ 0.990, goodness-of-fit coefficients ≤12.8%) in the range 2.5-200 µg kg(-1). The limits of detection and quantification for the four avermectins were in the range 0.05-0.68 and 0.17-2.27 µg kg(-1), respectively. Recoveries were 62.4-104.5% with good intra- and inter-day precision. The method was rapid, sensitive and reliable, and can be applied to the quantitative analysis of avermectin residues in different animal-food products.

  12. Advancing UAS methods for monitoring coastal environments

    Science.gov (United States)

    Ridge, J.; Seymour, A.; Rodriguez, A. B.; Dale, J.; Newton, E.; Johnston, D. W.

    2017-12-01

    Utilizing fixed-wing Unmanned Aircraft Systems (UAS), we are working to improve coastal monitoring by increasing the accuracy, precision, temporal resolution, and spatial coverage of habitat distribution maps. Generally, multirotor aircraft are preferred for precision imaging, but recent advances in fixed-wing technology have greatly increased their capabilities and application for fine-scale (decimeter-centimeter) measurements. Present mapping methods employed by North Carolina coastal managers involve expensive, time consuming and localized observation of coastal environments, which often lack the necessary frequency to make timely management decisions. For example, it has taken several decades to fully map oyster reefs along the NC coast, making it nearly impossible to track trends in oyster reef populations responding to harvesting pressure and water quality degradation. It is difficult for the state to employ manned flights for collecting aerial imagery to monitor intertidal oyster reefs, because flights are usually conducted after seasonal increases in turbidity. In addition, post-storm monitoring of coastal erosion from manned platforms is often conducted days after the event and collects oblique aerial photographs which are difficult to use for accurately measuring change. Here, we describe how fixed wing UAS and standard RGB sensors can be used to rapidly quantify and assess critical coastal habitats (e.g., barrier islands, oyster reefs, etc.), providing for increased temporal frequency to isolate long-term and event-driven (storms, harvesting) impacts. Furthermore, drone-based approaches can accurately image intertidal habitats as well as resolve information such as vegetation density and bathymetry from shallow submerged areas. We obtain UAS imagery of a barrier island and oyster reefs under ideal conditions (low tide, turbidity, and sun angle) to create high resolution (cm scale) maps and digital elevation models to assess habitat condition

  13. Data eye monitor method and apparatus

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Marcella, James A [Rochester, MN; Ohmacht, Martin [Yorktown Heights, NY

    2012-01-31

    An apparatus and method for providing a data eye monitor. The data eye monitor apparatus utilizes an inverter/latch string circuit and a set of latches to save the data eye for providing an infinite persistent data eye. In operation, incoming read data signals are adjusted in the first stage individually and latched to provide the read data to the requesting unit. The data is also simultaneously fed into a balanced XOR tree to combine the transitions of all incoming read data signals into a single signal. This signal is passed along a delay chain and tapped at constant intervals. The tap points are fed into latches, capturing the transitions at a delay element interval resolution. Using XORs, differences between adjacent taps and therefore transitions are detected. The eye is defined by segments that show no transitions over a series of samples. The eye size and position can be used to readjust the delay of incoming signals and/or to control environment parameters like voltage, clock speed and temperature.

  14. Chemical analysis of solid residue from liquid and solid fuel combustion: Method development and validation

    Energy Technology Data Exchange (ETDEWEB)

    Trkmic, M. [University of Zagreb, Faculty of Mechanical Engineering and Naval Architecturek Zagreb (Croatia); Curkovic, L. [University of Zagreb, Faculty of Chemical Engineering and Technology, Zagreb (Croatia); Asperger, D. [HEP-Proizvodnja, Thermal Power Plant Department, Zagreb (Croatia)

    2012-06-15

    This paper deals with the development and validation of methods for identifying the composition of solid residue after liquid and solid fuel combustion in thermal power plant furnaces. The methods were developed for energy dispersive X-ray fluorescence (EDXRF) spectrometer analysis. Due to the fuels used, the different composition and the location of creation of solid residue, it was necessary to develop two methods. The first method is used for identifying solid residue composition after fuel oil combustion (Method 1), while the second method is used for identifying solid residue composition after the combustion of solid fuels, i. e. coal (Method 2). Method calibration was performed on sets of 12 (Method 1) and 6 (Method 2) certified reference materials (CRM). CRMs and analysis test samples were prepared in pellet form using hydraulic press. For the purpose of method validation the linearity, accuracy, precision and specificity were determined, and the measurement uncertainty of methods for each analyte separately was assessed. The methods were applied in the analysis of real furnace residue samples. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Method of monitoring reactor power distribution

    International Nuclear Information System (INIS)

    Doi, Kazuyori; Kiguchi, Takashi; Yamada, Naoyuki.

    1981-01-01

    Purpose: To estimate reactor power distribution in a BWR type reactor in a short time thereby enable high speed monitoring as to whether the present power distribution lies within a certain range. Method: Calculation data for thermal power such as feedwater flow rate, temperature and recycling flow rate are inputted into an existent core performance calculation device to calculate the current thermal power distribution for the entire core. Further, the power distribution for the entire core is calculated based on the indication values from local power detectors in a computer. Coefficients are calculated using thermal power variation width and core flow rate variation width outputted from the core performance calculation device. The coefficients are multiplied with the newest power distribution data for the entire core stored in a memory device, and the multiplied values are compared in a comparator with a previously experienced distribution inputted from the core performance calculation device. (Furukawa, Y.)

  16. A Feasibility Study on Monitoring Residual Sugar and Alcohol Strength in Kiwi Wine Fermentation Using a Fiber-Optic FT-NIR Spectrometry and PLS Regression.

    Science.gov (United States)

    Wang, Bingqian; Peng, Bangzhu

    2017-02-01

    This work aims to investigate the potential of fiber-optic Fourier transform-near-infrared (FT-NIR) spectrometry associated with chemometric analysis, which will be applied to monitor time-related changes in residual sugar and alcohol strength during kiwi wine fermentation. NIR calibration models for residual sugar and alcohol strength during kiwi wine fermentation were established on the FT-NIR spectra of 98 samples scanned in a fiber-optic FT-NIR spectrometer, and partial least squares regression method. The results showed that R 2 and root mean square error of cross-validation could achieve 0.982 and 3.81 g/L for residual sugar, and 0.984 and 0.34% for alcohol strength, respectively. Furthermore, crucial process information on kiwi must and wine fermentations provided by fiber-optic FT-NIR spectrometry was found to agree with those obtained from traditional chemical methods, and therefore this fiber-optic FT-NIR spectrometry can be applied as an effective and suitable alternative for analyses and monitoring of those processes. The overall results suggested that fiber-optic FT-NIR spectrometry is a promising tool for monitoring and controlling the kiwi wine fermentation process. © 2017 Institute of Food Technologists®.

  17. Analysis of veterinary drug residue monitoring results for commercial livestock products in Taiwan between 2011 and 2015

    Directory of Open Access Journals (Sweden)

    Hsin-Chun Lee

    2018-04-01

    Full Text Available Antibiotics have been widely used in the treatment of livestock diseases. However, the emergence of issues related to drug resistance prompted governments to enact a series of laws regulating the use of antibiotics in livestock. Following control of the problem of drug resistant bacteria, public attention has shifted to the recurring incidence of human health and safety issues caused by residual veterinary drugs in livestock products. To guarantee the safety and hygiene of meat, milk, and eggs from food-producing animals, governments and relevant agencies established laws and regulations for the use of veterinary drugs. It is, therefore, necessary to monitor the content of residual drugs in livestock products at regular intervals to assess whether the regulations have resulted in the effective management of food product safety, and to prevent and manage sudden problems related to this issue. A 2011–2015 livestock product post-marketing monitoring program launched by the Taiwan Food and Drug Administration (TFDA inspected 1487 livestock products. Over the past 5 years, there were 34 samples identified that did not conform to the regulations; these samples included residue drugs such as β-agonists, chloramphenicols, β-lactam antibiotics, sulfa drugs, enrofloxacin, and lincomycin. Inspections of commercial livestock products with the consistent cooperation of agricultural authorities did not detect the drugs that were banned by the government, whereas the detection of other drugs decreased annually with an increase in the post-market monitoring sample size. In the future, the TFDA will continue to monitor the status of residual veterinary drugs in commercial livestock products, adjust the sampling of food products annually according to monitoring results, and closely cooperate with agricultural authorities on source management. Keywords: Agricultural authorities, Livestock products, Post-market monitoring, Veterinary drug residues

  18. Analytical N beam position monitor method

    Science.gov (United States)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  19. An adjoint method of sensitivity analysis for residual vibrations of structures subject to impacts

    Science.gov (United States)

    Yan, Kun; Cheng, Gengdong

    2018-03-01

    For structures subject to impact loads, the residual vibration reduction is more and more important as the machines become faster and lighter. An efficient sensitivity analysis of residual vibration with respect to structural or operational parameters is indispensable for using a gradient based optimization algorithm, which reduces the residual vibration in either active or passive way. In this paper, an integrated quadratic performance index is used as the measure of the residual vibration, since it globally measures the residual vibration response and its calculation can be simplified greatly with Lyapunov equation. Several sensitivity analysis approaches for performance index were developed based on the assumption that the initial excitations of residual vibration were given and independent of structural design. Since the resulting excitations by the impact load often depend on structural design, this paper aims to propose a new efficient sensitivity analysis method for residual vibration of structures subject to impacts to consider the dependence. The new method is developed by combining two existing methods and using adjoint variable approach. Three numerical examples are carried out and demonstrate the accuracy of the proposed method. The numerical results show that the dependence of initial excitations on structural design variables may strongly affects the accuracy of sensitivities.

  20. Evaluation of machining effect for the residual stress of SA508 by hole drilling method

    International Nuclear Information System (INIS)

    Lee, Jeong Kun; Lee, Kyoung Soo; Song, Ki O; Kim, Young Shin

    2009-01-01

    Residual stresses on a surface of the material are welcome or undesirable since it's direction, compression or tensile. But especially for the fatigue, it is not negligible effect on the material strength. These residual stresses developed during the manufacturing processes involving material deformation, heat treatment, machining. The object of this paper is verifying the effect of machining what is mostly used for SA508. For verifying the effect of machining, three different kind of machining have been achieved, milling, grinding, wire cutting. Also to measure the residual stress, hole drill method and indentation method are used.

  1. Numerical methods for calculating thermal residual stresses and hydrogen diffusion

    International Nuclear Information System (INIS)

    Leblond, J.B.; Devaux, J.; Dubois, D.

    1983-01-01

    Thermal residual stresses and hydrogen concentrations are two major factors intervening in cracking phenomena. These parameters were numerically calculated by a computer programme (TITUS) using the FEM, during the deposition of a stainless clad on a low-alloy plate. The calculation was performed with a 2-dimensional option in four successive steps: thermal transient calculation, metallurgical transient calculation (determination of the metallurgical phase proportions), elastic-plastic transient (plain strain conditions), hydrogen diffusion transient. Temperature and phase dependence of hydrogen diffusion coefficient and solubility constant. The following results were obtained: thermal calculations are very consistent with experiments at higher temperatures (due to the introduction of fusion and solidification latent heats); the consistency is not as good (by 70 degrees) for lower temperatures (below 650 degrees C); this was attributed to the non-introduction of gamma-alpha transformation latent heat. The metallurgical phase calculation indicates that the heat affected zone is almost entirely transformed into bainite after cooling down (the martensite proportion does not exceed 5%). The elastic-plastic calculations indicate that the stresses in the heat affected zone are compressive or slightly tensile; on the other hand, higher tensile stresses develop on the boundary of the heat affected zone. The transformation plasticity has a definite influence on the final stress level. The return of hydrogen to the clad during the bainitic transformation is but an incomplete phenomenon and the hydrogen concentration in the heat affected zone after cooling down to room temperature is therefore sufficient to cause cold cracking (if no heat treatment is applied). Heat treatments are efficient in lowering the hydrogen concentration. These results enable us to draw preliminary conclusions on practical means to avoid cracking. (orig.)

  2. Apparatus and method for monitoring stored material

    International Nuclear Information System (INIS)

    Price, W.E.; Lewis, D.R.; Galloway, L.A.; Lowrey, C.B.

    1983-01-01

    Material, e.g. radioactive waste or other hazardous material, which is to be stored and monitored is placed within the innermost container of a series of nested containers and monitoring fluids are circulated in a closed loop of fluid flow through the spaces between the nested containers. Monitoring devices are used to analyse said monitoring fluids to detect leakage of the stored material from the innermost nested container and to detect the migration of external fluids into the series of nested containers. A computer based monitoring system continually checks the values of various parameters of the monitoring fluids to immediately detect and report the presence of stored material or external fluid in the monitoring fluids. The stored material may then be immediately retrieved from storage to repair leaks in the series of nested containers. (author)

  3. [Multi-residue method for determination of veterinary drugs and feed additives in meats by HPLC].

    Science.gov (United States)

    Chonan, Takao; Fujimoto, Toru; Ueno, Ken-Ichi; Tazawa, Teijiro; Ogawa, Hiroshi

    2007-10-01

    A simple and rapid multi-residue method was developed for the determination of 28 kinds of veterinary drugs and feed additives (drugs) in muscle of cattle, pig and chicken. The drugs were extracted with acetonitrile-water (95:5) in a homogenizer and ultrasonic generator. The extracted solution was poured into an alumina column and the drugs were eluted with acetonitrile-water (90:10). The eluate was washed with n-hexane saturated with acetonitrile and then evaporated. The drugs were separated on a Inertsil ODS-3V column (4.6 mm i.d. x 250 mm) with a gradient system of 0.1% phosphoric acid-acetonitrile as the mobile phase, with monitoring at 280 and 340 nm. The recoveries of the 26 kinds of drugs were over 60% from the meats fortified at 0.1 microg/g, and the quantification limits of most drugs were 0.01 microg/g. This proposed method was found to be effective and suitable for the screening of the above drugs in meats.

  4. A Multifeatures Fusion and Discrete Firefly Optimization Method for Prediction of Protein Tyrosine Sulfation Residues.

    Science.gov (United States)

    Guo, Song; Liu, Chunhua; Zhou, Peng; Li, Yanling

    2016-01-01

    Tyrosine sulfation is one of the ubiquitous protein posttranslational modifications, where some sulfate groups are added to the tyrosine residues. It plays significant roles in various physiological processes in eukaryotic cells. To explore the molecular mechanism of tyrosine sulfation, one of the prerequisites is to correctly identify possible protein tyrosine sulfation residues. In this paper, a novel method was presented to predict protein tyrosine sulfation residues from primary sequences. By means of informative feature construction and elaborate feature selection and parameter optimization scheme, the proposed predictor achieved promising results and outperformed many other state-of-the-art predictors. Using the optimal features subset, the proposed method achieved mean MCC of 94.41% on the benchmark dataset, and a MCC of 90.09% on the independent dataset. The experimental performance indicated that our new proposed method could be effective in identifying the important protein posttranslational modifications and the feature selection scheme would be powerful in protein functional residues prediction research fields.

  5. New assays for monitoring residual HIV burden in effectively treated individuals

    Science.gov (United States)

    Strain, Matthew C.; Richman, Douglas D.

    2013-01-01

    Purpose of review Measurements of HIV burden have relied upon quantification of viral nucleic acids by real-time PCR (qPCR). To develop and test strategies for eradication, new methods are needed to better characterize residual cellular reservoirs in patients on suppressive antiretroviral therapy (ART). This review summarizes recent advances that may lead to clinically useful tests with improved sensitivity, reproducibility and throughput. Recent Findings HIV DNA remains the most sensitive measure of residual infection, but its low levels are difficult to differentiate from assay noise by qPCR. Digital PCR has begun to improve the precision of existing real-time assays, but there remains a need to distinguish replication-competent proviruses. Rapid technological progress in single-cell analysis is beginning to offer new approaches, notably CyTOF and microengraving, which could provide vastly more information about the composition of the latent reservoir. Summary To investigate and assess therapies directed towards eradication, improved assays that simultaneously offer high sensitivity, precision and information content will be needed. PMID:23314907

  6. Is residual memory variance a valid method for quantifying cognitive reserve? A longitudinal application.

    Science.gov (United States)

    Zahodne, Laura B; Manly, Jennifer J; Brickman, Adam M; Narkhede, Atul; Griffith, Erica Y; Guzman, Vanessa A; Schupf, Nicole; Stern, Yaakov

    2015-10-01

    Cognitive reserve describes the mismatch between brain integrity and cognitive performance. Older adults with high cognitive reserve are more resilient to age-related brain pathology. Traditionally, cognitive reserve is indexed indirectly via static proxy variables (e.g., years of education). More recently, cross-sectional studies have suggested that reserve can be expressed as residual variance in episodic memory performance that remains after accounting for demographic factors and brain pathology (whole brain, hippocampal, and white matter hyperintensity volumes). The present study extends these methods to a longitudinal framework in a community-based cohort of 244 older adults who underwent two comprehensive neuropsychological and structural magnetic resonance imaging sessions over 4.6 years. On average, residual memory variance decreased over time, consistent with the idea that cognitive reserve is depleted over time. Individual differences in change in residual memory variance predicted incident dementia, independent of baseline residual memory variance. Multiple-group latent difference score models revealed tighter coupling between brain and language changes among individuals with decreasing residual memory variance. These results suggest that changes in residual memory variance may capture a dynamic aspect of cognitive reserve and could be a useful way to summarize individual cognitive responses to brain changes. Change in residual memory variance among initially non-demented older adults was a better predictor of incident dementia than residual memory variance measured at one time-point. Copyright © 2015. Published by Elsevier Ltd.

  7. Analysis of residual toluene in food packaging via headspace extraction method using gas chromatography

    International Nuclear Information System (INIS)

    Lim, Ying Chin; Mohd Marsin Sanagi

    2008-01-01

    Polymeric materials are used in many food contact applications as packaging material. The presence of residual toluene in this food packaging material can migrate into food and thus affect the quality of food. In this study, a manual headspace analysis was successfully designed and developed. The determination of residual toluene was carried out with standard addition method and multiple headspace extraction, MHE) method using gas chromatography-flame ionization detector, GC-FID). Identification of toluene was performed by comparison of its retention time with standard toluene and GC-MS. It was found that the suitable heating temperature was 180 degree Celsius with an optimum heating time of 10 minutes. The study also found that the concentration of residual toluene in multicolored sample was higher compared to mono colored sample whereas residual toluene in sample analyzed using standard addition method was higher compared to MHE method. However, comparison with the results obtained from De Paris laboratory, France found that MHE method gave higher accuracy for sample with low analyte concentration. On the other hand, lower accuracy was obtained for sample with high concentration of residual toluene due to systematic errors. Comparison between determination methods showed that MHE method is more precise compared to standard addition method. (author)

  8. Vision-Inspection System for Residue Monitoring of Ready-Mixed Concrete Trucks

    Directory of Open Access Journals (Sweden)

    Deok-Seok Seo

    2015-01-01

    Full Text Available The objective of this study is to propose a vision-inspection system that improves the quality management for ready-mixed concrete (RMC. The proposed system can serve as an alternative to the current visual inspection method for the detection of residues in agitator drum of RMC truck. To propose the system, concept development and the system-level design should be executed. The design considerations of the system are derived from the hardware properties of RMC truck and the conditions of RMC factory, and then 6 major components of the system are selected in the stage of system level design. The prototype of system was applied to a real RMC plant and tested for verification of its utility and efficiency. It is expected that the proposed system can be employed as a practical means to increase the efficiency of quality management for RMC.

  9. A comparison of residual stresses in built-up steel beams using hole-drilling method

    International Nuclear Information System (INIS)

    Nawafleh, M. A.; Hunaiti, Y. M.; Younes, R. M.

    2009-01-01

    Residual stresses have a significant effect on the stability resistance of metal building systems. An experimental program was conducted to measure these stresses in built-up steel beams using incremental hole-drilling method. The experimental results reveal that the predicted residual stress type of pattern for built-up I-sections with fillet welds on one side of the web is not the same as the pattern of residual stresses in built-up I-sections with fillet welds on both sides of the web

  10. Calculation method for residual stress analysis of filament-wound spherical pressure vessels

    International Nuclear Information System (INIS)

    Knight, C.E. Jr.

    1976-01-01

    Filament wound spherical pressure vessels may be produced with very high performance factors. These performance factors are a calculation of contained pressure times enclosed volume divided by structure weight. A number of parameters are important in determining the level of performance achieved. One of these is the residual stress state in the fabricated unit. A significant level of an unfavorable residual stress state could seriously impair the performance of the vessel. Residual stresses are of more concern for vessels with relatively thick walls and/or vessels constructed with the highly anisotropic graphite or aramid fibers. A method is established for measuring these stresses. A theoretical model of the composite structure is required. Data collection procedures and techniques are developed. The data are reduced by means of the model and result in the residual stress analysis. The analysis method can be used in process parameter studies to establish the best fabrication procedures

  11. The Method of Validity Evaluation of Hard Coal Excavation in Residual Seam Parts

    Science.gov (United States)

    Wodarski, Krzysztof; Bijańska, Jolanta; Gumiński, Adam

    2017-12-01

    The excavation of residual seam parts should be justified by positive assessment of the purposefulness, technical feasibility and economic effectiveness. The results of the profitability evaluation are crucial in a decision making process. The excavation of residual seam parts, even if it is possible from a technical point of view, should not be implemented if it is economically inefficient or when accompanied by a very high risk of non-recovery of invested capital resources. The article presents the evaluation method of possibilities of excavating hard coal from residual seam parts, and the example of its use in one of collieries in the Upper Silesian Coal Basin. Working in line with the developed method, allows to indicate the variant of residual seam part exploitation, which is feasible to implement from a technical point of view, and which is characterized by the highest economic effectiveness and lowest risk.

  12. Residual stresses in LENS[reg] components using neutron diffraction and contour method

    International Nuclear Information System (INIS)

    Rangaswamy, P.; Griffith, M.L.; Prime, M.B.; Holden, T.M.; Rogge, R.B.; Edwards, J.M.; Sebring, R.J.

    2005-01-01

    During manufacturing of components by laser engineered net shaping (LENS[reg]), a solid freeform fabrication process, the introduction of residual stresses causes deformation or in the worst case, cracking. The origin is attributed to thermal transients encountered during solidification. In the absence of reliable predictive models for the residual stresses, measurements are necessary. Residual stresses were measured in LENS[reg] samples of 316 stainless steel and Inconel 718 having simple geometrical shapes by both neutron diffraction and the contour methods. The results by the two methods are compared and discussed in the context of the growth direction during the LENS[reg] process. Surprisingly, the residual stresses are practically uni-axial, with high stresses in the growth direction

  13. A Novel Method to Decrease Micro-residual Stresses of Fibrous Composites by Adding Carbon Nanotube

    Directory of Open Access Journals (Sweden)

    M. M. Shokrieh

    2013-12-01

    Full Text Available In this research, a novel method to decrease micro-residual stresses of fibrous composites by adding carbon nanotubes (CNTs is proposed in detail. The negative coefficient of thermal expansion and the high young’s modulus of CNTs can be utilized to counterbalance the process induced residual stresses in composites. To this end, first, the effects of adding CNTs to the matrix of fibrous composites in reducing the coefficient of thermal expansion (CTE and increasing of young’s modulus of matrix are studied theoretically. Then, a three phase micromechanical model (the energy method is used to model the effect of CNT in reducing the residual stresses of fibrous composites. The results show that by addition of CNTs, enhancements in properties of matrix are obtained and lead to decrease in micro-residual stresses of matrix and fiber up to 72%.

  14. Evaluation of Antibiotic Residues in Raw Meat Using Different Analytical Methods.

    Science.gov (United States)

    Ramatla, Tsepo; Ngoma, Lubanza; Adetunji, Modupeade; Mwanza, Mulunda

    2017-12-07

    Antibiotic residue in meat is a serious public health concern due to its harmful effects on consumer health. This study aimed at estimating the residue levels of four commonly used antibiotics in meat samples using three analytical methods (ELISA, TLC and HPLC). A total of 150 samples of raw meat from sales points were analysed for ciprofloxacin, streptomycin, tetracycline, and sulphanilamide residues. Overall, ELISA analysis showed that 56, 34, 18, and 25.3% of the samples tested positive for ciprofloxacin, streptomycin, sulphanilamide and tetracycline residues respectively while TLC and HPLC detected 21.4, 29.4, 92.5, and 14.6%, and 8.3, 41.1, 88.8, and 14.6% of the samples as containing the residues, with ciprofloxacin and sulphanilamide having the lowest and highest occurrence, respectively. Furthermore, the concentrations of antibiotic residues were in the ranges of 19.8-92.8, 26.6-489.1, 14.2-1280.8, and 42.6-355.6 μg/kg with ELISA, while HPLC detected concentration ranges of 20.7-82.1, 41.8-320.8, 65.2-952.2 and 32.8-95.6 μg/kg for sulphanilamide, tetracycline, streptomycin, and ciprofloxacin, respectively. Mean ciprofloxacin and streptomycin residue levels were above the Codex/SA MRL recommended limit, while 3% of the samples contained multidrug residues. Although some of the mean residues levels were below the permissible limits, the co-occurrence of multidrug residues in some of the samples calls for concern.

  15. Feasibility of ultrasonic and eddy current methods for measurement of residual stress in shot peened metals

    International Nuclear Information System (INIS)

    Lavrentyev, Anton I.; Stucky, Paul A.; Veronesi, William A.

    2000-01-01

    Shot peening is a well-known method for extending the fatigue life of metal components by introducing compressive residual stresses near their surfaces. The capability to nondestructively evaluate the near surface residual stress would greatly aid the assurance of proper fatigue life in shot-peened components. This paper presents preliminary results from a feasibility study examining the use of ultrasonic and eddy current NDE methods for residual stress measurement in components where the stress has been introduced by shot peening. With an ultrasonic method, a variation of ultrasonic surface wave speed with shot peening intensity was measured. Near surface conductivity was measured by eddy current methods. Since the effective penetration depth of both methods employed is inversely related to the excitation frequency, by making measurements at different frequencies, each method has the potential to provide the stress-depth profile. Experiments were conducted on aluminum specimens (alloy 7075-T7351) peened within the Almen peening intensity range of 4C to 16C. The experimental results obtained demonstrate a correlation between peening intensity and Rayleigh wave velocity and between peening intensity and conductivity. The data suggests either of the methods may be suitable, with limitations, for detecting unsatisfactory levels of shot peening. Several factors were found to contribute to the measured responses: surface roughness, near surface plastic deformation (cold work) and residual stress. The contribution of each factor was studied experimentally. The feasibility of residual stress determination from the measured data is discussed

  16. Method and apparatus for monitoring mercury emissions

    Science.gov (United States)

    Durham, Michael D.; Schlager, Richard J.; Sappey, Andrew D.; Sagan, Francis J.; Marmaro, Roger W.; Wilson, Kevin G.

    1997-01-01

    A mercury monitoring device that continuously monitors the total mercury concentration in a gas. The device uses the same chamber for converting speciated mercury into elemental mercury and for measurement of the mercury in the chamber by radiation absorption techniques. The interior of the chamber is resistant to the absorption of speciated and elemental mercury at the operating temperature of the chamber.

  17. Monitoring methods for nuclear fuel waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.B.; Barnard, J.W.; Bird, G.A. [and others

    1997-11-01

    This report examines a variety of monitoring activities that would likely be involved in a nuclear fuel waste disposal project, during the various stages of its implementation. These activities would include geosphere, environmental, vault performance, radiological, safeguards, security and community socioeconomic and health monitoring. Geosphere monitoring would begin in the siting stage and would continue at least until the closure stage. It would include monitoring of regional and local seismic activity, and monitoring of physical, chemical and microbiological properties of groundwater in rock and overburden around and in the vault. Environmental monitoring would also begin in the siting stage, focusing initially on baseline studies of plants, animals, soil and meteorology, and later concentrating on monitoring for changes from these benchmarks in subsequent stages. Sampling designs would be developed to detect changes in levels of contaminants in biota, water and air, soil and sediments at and around the disposal facility. Vault performance monitoring would include monitoring of stress and deformation in the rock hosting the disposal vault, with particular emphasis on fracture propagation and dilation in the zone of damaged rock surrounding excavations. A vault component test area would allow long-term observation of containers in an environment similar to the working vault, providing information on container corrosion mechanisms and rates, and the physical, chemical and thermal performance of the surrounding sealing materials and rock. During the operation stage, radiological monitoring would focus on protecting workers from radiation fields and loose contamination, which could be inhaled or ingested. Operational zones would be established to delineate specific hazards to workers, and movement of personnel and materials between zones would be monitored with radiation detectors. External exposures to radiation fields would be monitored with dosimeters worn by

  18. Monitoring EDTA process residuals in recombinant protein manufacturing using liquid chromatography.

    Science.gov (United States)

    Lin, Miao-Fang; Royal, Mabel; Hayenga, Kirk; Conn, Greg

    2003-07-25

    We have developed a chromatographic method for the high sensitivity quantitation of EDTA process residuals in recombinant protein manufacturing validation studies. The reversed-phase HPLC method is based upon the detection of Cu(2+)/EDTA complexes at 254 nm, and has been qualified for use on intermediates from a purification process for a recombinant protein expressed in E. coli. Quantitation of EDTA in recombinant protein process intermediates is linear in the range of 0.2 to 64 microM with LOD/LOQ values below 2.0 microM. The assay is suitable for use in process backgrounds containing Tris, HEPES, MES, NaCl, hexanediol, NH(4)SO(4), and PEG. EDTA spike recovery values in all process samples tested were greater than 90% at the 4.0 microM concentration. System suitability parameters for the chromatographic method were developed based upon peak area and retention time precision, column efficiency and USP tailing. Peak area precision and intermediate precision values across the linear range of the assay exhibited C.V. values less than 15% at any concentration tested in all sample backgrounds. The assay robustness was tested by transfer of the assay to a second laboratory and analyst with use of multiple process intermediate lots, reagent/column lots, and HPLC systems.

  19. Monitoring of Pesticide Residues in Commonly Used Fruits and Vegetables in Kuwait

    OpenAIRE

    Jallow, Mustapha F. A.; Awadh, Dawood G.; Albaho, Mohammed S.; Devi, Vimala Y.; Ahmad, Nisar

    2017-01-01

    The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers. The aim of this study was to assess the level of pesticide residues in commonly consumed fruits and vegetables in Kuwait. A total of 150 samples of different fresh vegetables and fruits were analyzed for the presence of 34 pesticides using the quick easy cheap effective rugged and safe (QuEChERS) multi-residue extraction, followed by gas chromatography-mass spectrometr...

  20. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data...... indicative of operating parameters of the medical scanner (104); determine an output of a verification function based on the tracking data and the scanner data (106); and control the scanning monitoring apparatus according to the output of the verification function (108). A notification signal may...

  1. Residual stress measurement of large scaled welded pipe using neutron diffraction method. Effect of SCC crack propagation and repair weld on residual stress distribution

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Katsuyama, Jinya; Tobita, Tohru; Morii, Yukio

    2011-01-01

    The RESA-1 neutron engineering diffractometer in the JRR-3 (Japan Research Reactor No.3) at the Japan Atomic Energy Agency, which is used for stress measurements, was upgraded to realize residual stress measurements of large scaled mechanical components. A series of residual stress measurements was made to obtain through-thickness residual stress distributions in a Type 304 stainless steel butt-welded pipe of 500A-sch.80 using the upgraded RESA-1 diffractometer. We evaluated effects of crack propagation such as stress corrosion cracking (SCC) and a part-circumference repair weld on the residual stress distributions induced by girth welding. Measured residual stress distributions near original girth weld revealed good agreement with typical results shown in some previous works using finite element method, deep hole drilling as well as neutron diffraction. After introducing a mock crack with 10 mm depth in the heat affected zone on the inside wall of the pipe by electro discharge machining, the axial residual stresses were found to be released in the part of the mock crack. However, changes in the through-wall bending stress component and the self-equilibrated stress component were negligible and hence the axial residual stress distribution in the ligament was remained in the original residual stresses near girth weld without the mock crack. Furthermore, changes in hoop and radial residual stress were also small. The residual stress distributions after a part repair welding on the outer circumference of the girth weld were significantly different from residual stress distributions near the original girth weld. The through-thickness average axial residual stress was increased due to increase of the tensile membrane stress and mitigation of the bending stress after repair welding. Throughout above studies, we evidenced that the neutron diffraction technique is useful and powerful tool for measuring residual stress distributions in large as well as thick mechanical

  2. Analysis of veterinary drug residue monitoring results for commercial livestock products in Taiwan between 2011 and 2015.

    Science.gov (United States)

    Lee, Hsin-Chun; Chen, Chi-Min; Wei, Jen-Ting; Chiu, Hsiu-Yi

    2018-04-01

    Antibiotics have been widely used in the treatment of livestock diseases. However, the emergence of issues related to drug resistance prompted governments to enact a series of laws regulating the use of antibiotics in livestock. Following control of the problem of drug resistant bacteria, public attention has shifted to the recurring incidence of human health and safety issues caused by residual veterinary drugs in livestock products. To guarantee the safety and hygiene of meat, milk, and eggs from food-producing animals, governments and relevant agencies established laws and regulations for the use of veterinary drugs. It is, therefore, necessary to monitor the content of residual drugs in livestock products at regular intervals to assess whether the regulations have resulted in the effective management of food product safety, and to prevent and manage sudden problems related to this issue. A 2011-2015 livestock product post-marketing monitoring program launched by the Taiwan Food and Drug Administration (TFDA) inspected 1487 livestock products. Over the past 5 years, there were 34 samples identified that did not conform to the regulations; these samples included residue drugs such as β-agonists, chloramphenicols, β-lactam antibiotics, sulfa drugs, enrofloxacin, and lincomycin. Inspections of commercial livestock products with the consistent cooperation of agricultural authorities did not detect the drugs that were banned by the government, whereas the detection of other drugs decreased annually with an increase in the post-market monitoring sample size. In the future, the TFDA will continue to monitor the status of residual veterinary drugs in commercial livestock products, adjust the sampling of food products annually according to monitoring results, and closely cooperate with agricultural authorities on source management. Copyright © 2017. Published by Elsevier B.V.

  3. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  4. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  5. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    Science.gov (United States)

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios 70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential emptying problems from those with sufficient gastric emptying. Refractometry and measurement of the BV may improve the clinical utilization of GRVs, by its ability to identify the component of formula within gastric contents and track changes in that component related

  6. Residual power series method for fractional Sharma-Tasso-Olever equation

    Directory of Open Access Journals (Sweden)

    Amit Kumar

    2016-02-01

    Full Text Available In this paper, we introduce a modified analytical approximate technique to obtain solution of time fractional Sharma-Tasso-Olever equation. First, we present an alternative framework of the Residual power series method (RPSM which can be used simply and effectively to handle nonlinear fractional differential equations arising in several physical phenomena. This method is basically based on the generalized Taylor series formula and residual error function. A good result is found between our solution and the given solution. It is shown that the proposed method is reliable, efficient and easy to implement on all kinds of fractional nonlinear problems arising in science and technology.

  7. Prevalence of antibiotic residues in commercial milk and its variation by season and thermal processing methods

    Directory of Open Access Journals (Sweden)

    Fathollah Aalipour

    2013-01-01

    Full Text Available Aims: In this study, the prevalence of antibiotic residues in pasteurized and sterilized commercial milk available in Shahre-kourd, Iran, was investigated. In addition, the influence of seasonal temperature changes on the prevalence of contamination was studied. Materials and Methods: Commercial milk samples of 187, including 154 pasteurized and 33 sterilized, milk samples were collected from the market between early January 2012 and late July of the same year. The presence of antibiotic residues was detected using the microbiological detection test kit, Eclipse 100, as a semi-quantitative method. Results: The results showed that 37 of the samples (19.8% have contained antibiotic residues above the European Union Maximum Residues Limits (EU-MRLs, of which 28 samples (14.97% were found to be contaminated but at the concentrations below the EU-MRLs. There was no significant difference between the contamination rate of pasteurized and Ultra High Temperature (UHT-sterilized samples. Similarly, variation of weather temperature with seasons had no effect on the contamination prevalence of milk samples ( P > 0.05. Conclusion: Based on the result of this study, antibiotics residues were present in the majority of milk samples. Neither the season nor the type of thermal processing of the commercial milks had noticeable impact on the prevalence level of the milk samples. However, an increasing trend of prevalence level for antibiotic residues was observed with increasing the temperature through the warm season.

  8. Body monitoring and imaging apparatus and method

    Science.gov (United States)

    McEwan, T.E.

    1998-06-16

    A non-acoustic pulse-echo radar monitor is employed in the repetitive mode, whereby a large number of reflected pulses are averaged to produce a voltage that modulates an audio oscillator to produce a tone that corresponds to the heart motion. The antenna used in this monitor generally comprises two flat copper foils, thus permitting the antenna to be housed in a substantially flat housing. The monitor converts the detected voltage to an audible signal with both amplitude modulation and Doppler effect. It further uses a dual time constant to reduce the effect of gross sensor-to-surface movement. The monitor detects the movement of one or more internal body parts, such as the heart, lungs, arteries, and vocal chords, and includes a pulse generator for simultaneously inputting a sequence of pulses to a transmit path and a grating path. The pulses transmitted along the transmit path drive Oh impulse, generator and provide corresponding transmit pulses that are applied to a transmit antenna. The gating path includes a range delay generator which generates timed gating pulses. The timed gating pulses cause the receive path to selectively conduct pulses reflected from the body parts and received by a receive antenna. The monitor output potential can be separated into a cardiac output indicative of the physical movement of the heart, and a pulmonary output indicative of the physical movement of the lung. The impulse generator in the transmit path can be replaced with a pulsed RF generator. 13 figs.

  9. Minimal Residual Disease Monitoring of Acute Myeloid Leukemia by Massively Multiplex Digital PCR in Patients with NPM1 Mutations.

    Science.gov (United States)

    Mencia-Trinchant, Nuria; Hu, Yang; Alas, Maria Antonina; Ali, Fatima; Wouters, Bas J; Lee, Sangmin; Ritchie, Ellen K; Desai, Pinkal; Guzman, Monica L; Roboz, Gail J; Hassane, Duane C

    2017-07-01

    The presence of minimal residual disease (MRD) is widely recognized as a powerful predictor of therapeutic outcome in acute myeloid leukemia (AML), but methods of measurement and quantification of MRD in AML are not yet standardized in clinical practice. There is an urgent, unmet need for robust and sensitive assays that can be readily adopted as real-time tools for disease monitoring. NPM1 frameshift mutations are an established MRD marker present in half of patients with cytogenetically normal AML. However, detection is complicated by the existence of hundreds of potential frameshift insertions, clonal heterogeneity, and absence of sequence information when the NPM1 mutation is identified using capillary electrophoresis. Thus, some patients are ineligible for NPM1 MRD monitoring. Furthermore, a subset of patients with NPM1-mutated AML will have false-negative MRD results because of clonal evolution. To simplify and improve MRD testing for NPM1, we present a novel digital PCR technique composed of massively multiplex pools of insertion-specific primers that selectively detect mutated but not wild-type NPM1. By measuring reaction end points using digital PCR technology, the resulting single assay enables sensitive and specific quantification of most NPM1 exon 12 mutations in a manner that is robust to clonal heterogeneity, does not require NPM1 sequence information, and obviates the need for maintenance of hundreds of type-specific assays and associated plasmid standards. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  10. A direct qPCR method for residual DNA quantification in monoclonal antibody drugs produced in CHO cells.

    Science.gov (United States)

    Hussain, Musaddeq

    2015-11-10

    Chinese hamster ovary (CHO) cells are the host cell of choice for manufacturing of monoclonal antibody (mAb) drugs in the biopharmaceutical industry. Host cell DNA is an impurity of such manufacturing process and must be controlled and monitored in order to ensure drug purity and safety. A conventional method for quantification of host residual DNA in drug requires extraction of DNA from the mAb drug substance with subsequent quantification of the extracted DNA using real-time PCR (qPCR). Here we report a method where the DNA extraction step is eliminated prior to qPCR. In this method, which we have named 'direct resDNA qPCR', the mAb drug substance is digested with a protease called KAPA in a 96-well PCR plate, the protease in the digest is then denatured at high temperature, qPCR reagents are added to the resultant reaction wells in the plate along with standards and controls in other wells of the same plate, and the plate subjected to qPCR for analysis of residual host DNA in the samples. This direct resDNA qPCR method for CHO is sensitive to 5.0fg of DNA with high precision and accuracy and has a wide linear range of determination. The method has been successfully tested with four mAbs drug, two IgG1 and two IgG4. Both the purified drug substance as well as a number of process intermediate samples, e.g., bioreactor harvest, Protein A column eluate and ion-exchange column eluates were tested. This method simplifies the residual DNA quantification protocol, reduces time of analysis and leads to increased assay sensitivity and development of automated high-throughput methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  12. Risk assessment and risk management at the Canadian Food Inspection Agency (CFIA): a perspective on the monitoring of foods for chemical residues.

    Science.gov (United States)

    Bietlot, Henri P; Kolakowski, Beata

    2012-08-01

    The Canadian Food Inspection Agency (CFIA) uses 'Ranked Risk Assessment' (RRA) to prioritize chemical hazards for inclusion in monitoring programmes or method development projects based on their relative risk. The relative risk is calculated for a chemical by scoring toxicity and exposure in the 'risk model scoring system' of the Risk Priority Compound List (RPCL). The relative ranking and the risk management options are maintained and updated in the RPCL. The ranking may be refined by the data generated by the sampling and testing programs. The two principal sampling and testing programmes are the National Chemical Residue Monitoring Program (NCRMP) and the Food Safety Action Plan (FSAP). The NCRMP sampling plans focus on the analysis of federally registered products (dairy, eggs, honey, meat and poultry, fresh and processed fruit and vegetable commodities, and maple syrup) for residues of veterinary drugs, pesticides, environmental contaminants, mycotoxins, and metals. The NCRMP is complemented by the Food Safety Action Plan (FSAP) targeted surveys. These surveys focus on emerging chemical hazards associated with specific foods or geographical regions for which applicable maximum residue limits (MRLs) are not set. The data from the NCRMP and FSAP also influence the risk management (follow-up) options. Follow-up actions vary according to the magnitude of the health risk, all with the objective of preventing any repeat occurrence to minimize consumer exposure to a product representing a potential risk to human health. © Her Majesty the Queen in Right of Canada 2012. Drug Testing and Analysis © 2012 John Wiley & Sons, Ltd.

  13. A method to evaluate residual phase error for polar formatted synthetic aperture radar systems

    Science.gov (United States)

    Musgrove, Cameron; Naething, Richard

    2013-05-01

    Synthetic aperture radar systems that use the polar format algorithm are subject to a focused scene size limit inherent to the polar format algorithm. The classic focused scene size limit is determined from the dominant residual range phase error term. Given the many sources of phase error in a synthetic aperture radar, a system designer is interested in how much phase error results from the assumptions made with the polar format algorithm. Autofocus algorithms have limits to the amount and type of phase error that can be corrected. Current methods correct only one or a few terms of the residual phase error. A system designer needs to be able to evaluate the contribution of the residual or uncorrected phase error terms to determine the new focused scene size limit. This paper describes a method to estimate the complete residual phase error, not just one or a few of the dominant residual terms. This method is demonstrated with polar format image formation, but is equally applicable to other image formation algorithms. A benefit for the system designer is that additional correction terms can be added or deleted from the analysis as necessary to evaluate the resulting effect upon image quality.

  14. The gravimetric method for the determination of residual moisture in freeze-dried biological products.

    Science.gov (United States)

    May, J C; Wheeler, R M; Grim, E

    1989-06-01

    The gravimetric test for the determination of residual moisture in freeze-dried biological products performed in a humidity- and temperature-controlled room with the use of scrupulous gravimetric analytical technique can be used to accurately determine residual moisture in freeze-dried biological products such as antihemophilic factor (human) or honey bee venom allergenic extract. This method determines the first water of hydration of sodium tartrate dihydrate (7.93%) to within 1.3% of the calculated value with a relative standard deviation of 0.3% for 10 replicates. For this gravimetric procedure, freeze-dried samples containing from 1.12 to 4.4% residual moisture had relative standard deviations ranging from 3.6 to 9.1%. Samples containing less than 1.0% residual moisture by the gravimetric method such as intravenous immune globulin and antihemophilic factor (human) had relative standard deviations ranging from 16.7 to 47.0%. Relative standard deviations for residual moisture tests performed on comparable samples by the Karl Fischer and thermogravimetric methods showed similar variability.

  15. Multi-residue methods for confirmatory determination of antibiotics in milk.

    Science.gov (United States)

    Samanidou, Victoria; Nisyriou, Styliani

    2008-06-01

    The prevalent use of antibiotics, e. g. sulphonamides, tetracyclines, beta-lactams, macrolides, aminoglycosides, etc., in dairy farming to prevent and treat microbial infections e. g. mastitis, can be a potential source of veterinary drug residues in milk. Antibiotic residues constitute a risk to human health, since they can cause allergic reactions in hypersensitive individuals or they may lead to the appearance of drug-resistant bacteria. Analysis of these residues plays a key role in ensuring food safety. Regulatory agencies in the European Union and in other countries have established maximum residue limits and requirements concerning the performance of analytical methods and the interpretation of the results. This review describes the state of the art in the analytical strategies concerning the multi-class as well as the multi-residue analysis of antibiotics in milk. Since milk is a complex matrix due to its high protein and fat content, which often interfere in analytical procedures, special focus has been placed on sample preparation: extraction and clean-up. Confirmation of antibiotic residues according to European Decision 657/2002/EC has been also discussed.

  16. Determination of Profenofos Pesticidal Residue in Lettuce (Lactuca sativa L. by Gas Chromatographic Method

    Directory of Open Access Journals (Sweden)

    Yohannes Alen

    2015-05-01

    Full Text Available The determination of profenofos pesticidal residue in the lettuce (Lactuca sativa L. by using gas chromatography using flame photometric detector (FPD had been investigated. The lettuce was collected from Padang Luar area, Agam distric, West Sumatera. Sample for determination of profenofos residue divided into three groups: unwashed (A, washed with water (B, and washed with detergent (C. Maceration with sonication was used for the extraction using ethylacetateas a solvent. The results showed that profenofos pesticide residue in sample A, B and C were 0.204, 0.080 and 0.061 ppm, respectively. These profenofos pesticidal residue are over than the Maximum Residue Limits (MRL that established by The Japan Food Chemical Research Foundation (0.05 ppm even though World Health Organization (WHO has not established Maximum Residue Limits (MRL profenofos on lettuce. Based on the statistical analysis one-way method (Anova using SPSS 20.0 showed that there was a significant concentrations difference between lettuce A from lettuce B and lettuce C with p < 0.05.

  17. Method and apparatus for neutron radiation monitoring

    International Nuclear Information System (INIS)

    Schwarzmann, A.

    1985-01-01

    A self-calibrated neutron radiation monitor includes a flux responsive element comprised of intrinsic silicon neutron detectors and self-calibration resistors in a single structure. As the resistance of the flux responsive element increases to the value of successive calibration resistors, known increments of flux have been encountered

  18. Radio monitoring problems, methods, and equipment

    CERN Document Server

    Rembovsky, Anatoly; Kozmin, Vladimir; Smolskiy, Sergey

    2009-01-01

    Offers a unified approach to fundamental aspects of Automated Radio Monitoring (ARM). This book discusses the development, modeling, design, and manufacture of ARM systems. It provides classification and descriptions of modern high-efficient hardware-software ARM equipment, including the equipment for detection and radio direction-finding.

  19. Residual nitrogen-15 recovery by corn as influenced by tillage and fertilization method

    International Nuclear Information System (INIS)

    Timmons, D.R.; Cruse, R.M.

    1991-01-01

    Tillage systems that create different surface residue conditions may also affect the recovery of residual fertilizer N during subsequent growing seasons. This study evaluated the recovery of residual labeled N fertilizer in the soil by corn (Zea mays L.) for two tillage systems and two fertilization methods. Five atom % 15 N-enriched 28% urea-ammonium nitrate solution (UAN) at 224 kg N ha -1 was either surface-applied in the fall before any primary tillage or banded (knifed in) just before planting in the spring. Continuous corn was grown with either fall moldboard-plow (MP) or ridge-till (RT) systems. After the initial growing season, the recovery of residual labeled N in the soil by corn was determined for three consecutive growing seasons, and the soil profile was sampled periodically to measure residual 15 N in the organic and inorganic pools. One year after labeled UAN application, from 16 to 27% of the initial 15 N applied was found in the organic N pool and only 1% as inorganic N[NH 4 +(NO 2 +NO 3 )-N]. After four seasons, residual 15 N in the organic N pool ranged from 13 to 24%. Less than 0.5% remained as inorganic N. Regression analyses indicated that about 5 kg 15 N ha -1 year -1 became available for both MP and RT systems with banded N, so the amounts were small. Total residual 15 N recovery by corn grain plus stover for three seasons ranged from 1.7 to 3.5%, and was greatest for spring-banded fertilizer. Because the amounts of residual 15 N utilized were too small to affect corn growth, this N source appears to be negligible when considering corn-N needs

  20. Online monitoring method of degree of cure during non-isothermal microwave curing process

    Science.gov (United States)

    He, Yongxi; Li, Yingguang; Li, Nanya; Hao, Xiaozhong

    2018-02-01

    Curing rate is the variation rate of degree of cure with time, which is a crucial issue in the curing process of composite structures since it has a significant influence on the generation of voids and residual stresses. In this paper, an online monitoring method of degree of cure was presented based on refractive index measurement. The influence of cure and temperature variation on the refractive index of composite was separated in real time with a step-temperature refractive index separation method. Non-isothermal microwave curing process of carbon fiber/epoxy composite was monitored, and the degree of cure was obtained with a low measurement error of ±1.5% compared with that determined by off-line DSC measurement. The online monitoring method is a promising technology for smart manufacturing of composite structures.

  1. Evaluation of Methods for the Calculation of the pKa of Cysteine Residues in Proteins.

    Science.gov (United States)

    Awoonor-Williams, Ernest; Rowley, Christopher N

    2016-09-13

    Methods for the calculation of the pKa ionizable amino acids are valuable tools for understanding pH-dependent properties of proteins. Cysteine is unique among the amino acids because of the chemical reactivity of its thiol group (S-H), which plays an instrumental role in several biochemical and regulatory functions. The acidity of noncatalytic cysteine residues is a factor in their susceptibility to chemical modification. Despite the plethora of existing pKa computing methods, no definitive protocol exists for accurately calculating the pKa's of cysteine residues in proteins. A cysteine pKa test set was developed, which is comprised of 18 cysteine residues in 12 proteins where the pKa's have been determined experimentally and an experimental structure is available. The pKa's of these residues were calculated using three methods that use an implicit solvent model (H++, MCCE, and PROPKA) and an all-atom replica-exchange thermodynamic integration approach with the CHARMM36 and AMBER ff99SB-ILDNP force fields. The models that use implicit solvation methods were generally unreliable in predicting cysteine residue pKa's, with RMSDs between 3.41 and 4.72 pKa units. On average, the explicit solvent methods performed better than the implicit solvent methods. RMSD values of 2.40 and 3.20 were obtained for simulations with the CHARMM36 and AMBER ff99SB-ILDNP force fields, respectively. Further development of these methods is necessary because the performance of the best method is similar to that of the null-model (RMSD = 2.74) and these differences in RMSD are of limited statistical significance given the small size of our test set.

  2. Qualitative screening method for pesticide residues detection in fruits and vegetables

    Directory of Open Access Journals (Sweden)

    Iván Mauricio Huérfano Barco

    2018-01-01

    Full Text Available Because of the importance of developing methodologies that allow agricultural residues analysis, a rapid screening qualitative method for the determination of pesticides residues in fruits and vegetables was validated. The methodology was based on the European QuEChERS extraction method with an additional cleaning step by gel permeation chromatography (GPC, which helped to reduce the number of matrix components in the final extract. The analysis was carried out by gas chromatography coupled to mass spectrometry with a single quadrupole analyzer. The methodology was appropriate for the qualitative analysis of 31 pesticides at their respective maximum residue limits. Consistent results were obtained with respect to a quantitative routine methodology in the analysis of real samples, hence the methodology was proven to be a good alternative for the fast analysis of these contaminants in fruits and vegetables.

  3. Residues of Eight Antibiotics in Vegetable Soils Affected by Fertilization Methods

    Directory of Open Access Journals (Sweden)

    BAO Chen-yan

    2014-08-01

    Full Text Available Total forty-four representative soil samples were collected from vegetable fields in Hangzhou, Jiaxing, and Shaoxing city of Zhe-jiang Province for measuring concentrations of eight antibiotics, including chloroteracycline, tetracycline, oxytetracyline, enrofloxacin, sulfa-diazine, sulfamethazine, sulfamethoxazole, and tylosin. Effects of four fertilization methods(application of livestock and poultry manure, appli-cation of commercial organic fertilizer, application of biogas residue and application of chemical fertilizeron residues of the antibiotics in the soils were investigated. The results showed that the detection proportions and concentrations of the antibiotics in the soils varied with appli-cation methods of fertilizers and species of antibiotics. The concentration of chloroteracycline in the soils was much higher than those of other antibiotics. Mean percentage proportion of chloroteracycline in total residues of eight antibiotics was 67.03%. The detection proportions and concentrations of the antibiotics decreased in the sequence of chloroteracycline>sulfamethazine>enrofloxacin>tetracycline>sulfamethoxazole, tylosin>oxytetracycline>sulfadiazine. The detection proportion and concentration of the tetracyclines were greater than those of the sulfon-amides. The residues of the antibiotics in the soils applied with livestock and poultry manure were much greater than those of other vegetable soils, and the detection proportions and concentrations of the antibiotics in the soils decreased in the sequence of fields with application of livestock and poultry manure>fields with application of commercial organic fertilizer>fields with application of biogas residue>fields with ap-plication of chemical fertilizer. The results indicate that the livestock and poultry manure is the main source of antibiotics in vegetable soils, and application of commercial organic fertilizer and biogas residue also have certain contribution to antibiotics residues

  4. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    Science.gov (United States)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  5. RSARF: Prediction of residue solvent accessibility from protein sequence using random forest method

    KAUST Repository

    Ganesan, Pugalenthi

    2012-01-01

    Prediction of protein structure from its amino acid sequence is still a challenging problem. The complete physicochemical understanding of protein folding is essential for the accurate structure prediction. Knowledge of residue solvent accessibility gives useful insights into protein structure prediction and function prediction. In this work, we propose a random forest method, RSARF, to predict residue accessible surface area from protein sequence information. The training and testing was performed using 120 proteins containing 22006 residues. For each residue, buried and exposed state was computed using five thresholds (0%, 5%, 10%, 25%, and 50%). The prediction accuracy for 0%, 5%, 10%, 25%, and 50% thresholds are 72.9%, 78.25%, 78.12%, 77.57% and 72.07% respectively. Further, comparison of RSARF with other methods using a benchmark dataset containing 20 proteins shows that our approach is useful for prediction of residue solvent accessibility from protein sequence without using structural information. The RSARF program, datasets and supplementary data are available at http://caps.ncbs.res.in/download/pugal/RSARF/. - See more at: http://www.eurekaselect.com/89216/article#sthash.pwVGFUjq.dpuf

  6. Asymptotic Solutions of Time-Space Fractional Coupled Systems by Residual Power Series Method

    Directory of Open Access Journals (Sweden)

    Wenjin Li

    2017-01-01

    Full Text Available This paper focuses on the asymptotic solutions to time-space fractional coupled systems, where the fractional derivative and integral are described in the sense of Caputo derivative and Riemann-Liouville integral. We introduce the Residual Power Series (for short RPS method to construct the desired asymptotic solutions. Furthermore, we apply this method to some time-space fractional coupled systems. The simplicity and efficiency of RPS method are shown by the application.

  7. Fibonacci collocation method with a residual error Function to solve linear Volterra integro differential equations

    Directory of Open Access Journals (Sweden)

    Salih Yalcinbas

    2016-01-01

    Full Text Available In this paper, a new collocation method based on the Fibonacci polynomials is introduced to solve the high-order linear Volterra integro-differential equations under the conditions. Numerical examples are included to demonstrate the applicability and validity of the proposed method and comparisons are made with the existing results. In addition, an error estimation based on the residual functions is presented for this method. The approximate solutions are improved by using this error estimation.

  8. In-house method validation and occurrence of alpha-, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone and trifluralin residues in strawberry

    Directory of Open Access Journals (Sweden)

    Alexandre Augusto Soares

    2013-12-01

    Full Text Available A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8% had residues of unauthorized pesticide for the culture of strawberry, one (0.5% had residues above the maximum residue limit, and another one (0.5% exhibited both non-conformities.

  9. Photography - Determination of thiosulphate and other residual chemicals in processed photographic films, plates and papers - Methylene blue photometric method and silver sulphide densitometric method

    CERN Document Server

    International Organization for Standardization. Geneva

    1977-01-01

    Photography - Determination of thiosulphate and other residual chemicals in processed photographic films, plates and papers - Methylene blue photometric method and silver sulphide densitometric method

  10. Composting of solid and sludge residues from agricultural and food industries. Bioindicators of monitoring and compost maturity.

    Science.gov (United States)

    Ranalli, G; Bottura, G; Taddei, P; Garavani, M; Marchetti, R; Sorlini, C

    2001-01-01

    A study to monitor the composting process, to evaluate the effectiveness of bioindicators for the quality and maturity of cured compost obtained by a mixture of winery residues, sludges from dairies and solid residues from food processing (grape-stalks, grape-dregs, rice husks), was conducted. Composting process lasting five months was monitored by chemico-physical, spectroscopic (FTIR, DTG and DSC), microbiological and enzymatic analyses. Biological activities (ATP, DHA contents and several enzymatic activities), impedance variations (DT) of mixed cultures during growth and potential pathogens (E. coli and Salmonella sp.), were determined. The phytotoxicity tests gave a germination index higher than 90% and no significant genotoxic differences between controls and the compost samples were evidenced. Pathogens were not found on the cured compost that can therefore be satisfactorily used as amendment for agricultural crops. However, no single measurement of a composting process factor, biological, chemical or physical, gave a comprehensive view of the quality of a specific composting. We proposed a tool of bioindicators of potential activity and markers in combination for integrated evaluation of monitoring of composting process and compost quality. The responses of several enzymatic activities were positive and indicative of their favorable use capable to reveal even very small changes within microbial population and activity in test and monitoring of compost programmes.

  11. Optimal layout of radiological environment monitoring based on TOPSIS method

    International Nuclear Information System (INIS)

    Li Sufen; Zhou Chunlin

    2006-01-01

    TOPSIS is a method for multi-objective-decision-making, which can be applied to comprehensive assessment of environmental quality. This paper adopts it to get the optimal layout of radiological environment monitoring, it is proved that this method is a correct, simple and convenient, practical one, and beneficial to supervision departments to scientifically and reasonably layout Radiological Environment monitoring sites. (authors)

  12. Development of nondestructive hybrid measuring method for three-dimensional residual stress distribution of thick welded joint. Hybrid measuring method of inherent strain method and neutron diffraction method

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Kasahara, Norifumi; Tamura, Ryota

    2012-01-01

    The measuring methods of the residual stress are classified into destructive one and nondestructive one. The inherent strain method (ISM) is destructive one. The neutron diffraction method (NDM) is nondestructive one. But the measurable depth is limited within about 20 mm and the method cannot measure the weld zone, without destruction of the object. So, in this study, the hybrid measuring method has been developed, by combining the ISM and the NDM. The theory of the hybrid method is the same as the ISM. In the analysis, the strains measured by the NDM without destruction are used. This hybrid measuring method is a true nondestructive measuring method for a thick welded joint. The applicability of the hybrid method has been verified by simulation, using a butt welded joint of thick pipes. In the simulation, the reliable order of the strains measured by the present NDM is very important, and was considered as 10 micro. The measurable regions by the present NDM were assumed. Under the above conditions, the data (the residual elastic strains assumed to be measured by the NDM) were made, and used in the ISM. As a result of such simulation, it has been cleared that the estimated residual stress has very high accuracy, if enough data are used. The required number of data is less than the ISM. (author)

  13. Effect of depth of planting, methods of planting and animal residues ...

    African Journals Online (AJOL)

    This study was carried out in farmers' field, from March to December in 2014 and 2015 cropping seasons at the research site of the Lower Niger River Basin Development Authority, Ejiba, Kogi State of Nigeria to investigate the effect of depth of planting, methods of planting and animal residues application on the growth and ...

  14. A method for computing the inter-residue interaction potentials for ...

    Indian Academy of Sciences (India)

    PRAKASH KUMAR

    2007-06-16

    Jun 16, 2007 ... [Luthra A, Jha A N, Ananthasuresh G K and Vishveswara S 2007 A method for computing the inter-residue interaction potentials for reduced amino acid alphabet; J. ... Therefore, a systematic approach to this problem is warranted so ... chemical and biological or quantitative measures are used. Dayhoff et al ...

  15. Nouws antibiotics test: Validation of a post-screening method for antibiotic residues in kidney

    NARCIS (Netherlands)

    Pikkemaat, M.G.; Oostra-van Dijk, S.; Schouten, J.; Rapallini, M.; Kortenhoeven, L.; Egmond, van H.J.

    2009-01-01

    Anticipating the rise in ‘suspect’ samples caused by the introduction of a more sensitive screening test for the presence of antibiotic residues in slaughter animals, an additional microbial post-screening method was developed. The test comprises four antibiotic group specific test plates, optimized

  16. Hanford Site groundwater monitoring: Setting, sources and methods

    International Nuclear Information System (INIS)

    Hartman, M.J.

    2000-01-01

    Groundwater monitoring is conducted on the Hanford Site to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA); Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA); U.S. Department of Energy (DOE) orders; and the Washington Administrative Code. Results of monitoring are published annually (e.g., PNNL-11989). To reduce the redundancy of these annual reports, background information that does not change significantly from year to year has been extracted from the annual report and published in this companion volume. This report includes a description of groundwater monitoring requirements, site hydrogeology, and waste sites that have affected groundwater quality or that require groundwater monitoring. Monitoring networks and methods for sampling, analysis, and interpretation are summarized. Vadose zone monitoring methods and statistical methods also are described. Whenever necessary, updates to information contained in this document will be published in future groundwater annual reports

  17. Hanford Site groundwater monitoring: Setting, sources and methods

    Energy Technology Data Exchange (ETDEWEB)

    M.J. Hartman

    2000-04-11

    Groundwater monitoring is conducted on the Hanford Site to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA); Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA); U.S. Department of Energy (DOE) orders; and the Washington Administrative Code. Results of monitoring are published annually (e.g., PNNL-11989). To reduce the redundancy of these annual reports, background information that does not change significantly from year to year has been extracted from the annual report and published in this companion volume. This report includes a description of groundwater monitoring requirements, site hydrogeology, and waste sites that have affected groundwater quality or that require groundwater monitoring. Monitoring networks and methods for sampling, analysis, and interpretation are summarized. Vadose zone monitoring methods and statistical methods also are described. Whenever necessary, updates to information contained in this document will be published in future groundwater annual reports.

  18. Nuclear analysis methods in monitoring occupational health

    International Nuclear Information System (INIS)

    Clayton, E.

    1985-01-01

    With the increasing industrialisation of the world has come an increase in exposure to hazardous chemicals. Their effect on the body depends upon the concentration of the element in the work environment; its chemical form; the possible different routes of intake; and the individual's biological response to the chemical. Nuclear techniques of analysis such as neutron activation analysis (NAA) and proton induced X-ray emission analysis (PIXE), have played an important role in understanding the effects hazardous chemicals can have on occupationally exposed workers. In this review, examples of their application, mainly in monitoring exposure to heavy metals is discussed

  19. Monitoring heavy metals, residual agricultural chemicals and sulfites in traditional herbal decoctions.

    Science.gov (United States)

    Yu, In-Sil; Lee, Jeong-Sook; Kim, Sung-Dan; Kim, Yun-Hee; Park, Hae-Won; Ryu, Hoe-Jin; Lee, Jib-Ho; Lee, Jeong-Mi; Jung, Kweon; Na, Cheol; Joung, Jin-Yong; Son, Chang-Gue

    2017-03-14

    Asian traditional herbal preparations are frequently considered for the contamination with undeclared toxic or hazardous substances. The aim of this study was to determine the toxic heavy metals, pesticides and sulfur dioxide in decoctions that is a common form of final utilization in Korea. A total of 155 decoctions composed of multi-ingredient traditional herbs were randomly sampled from Seoul in Korea between 2013 and 2014. For each decoction, the concentrations of four heavy metals (arsenic, cadmium, lead and mercury), 33 pesticides and sulfur dioxide were analyzed using inductively coupled plasma mass spectrometry (ICP-MS), mercury analyzer, gas chromatography/nitrogen phosphorous detector (GC/NPD), gas chromatography/micro electron capture detector (GC/μECD), and Monier-Williams method respectively. One hundred fifty-two of One hundred fifty-five decoctions (98.1%) contained one of three heavy metals (96.1% for As, 97.4% for Cd, and 90.3% for Pb, 0.0% for Hg). Their average concentrations (77.0 ± 79.7 ug/kg for As, 20.4 ± 23.7 ug/kg for Cd, and 68.8 ± 76.5 ug/kg for Pb) were approximately 20% of the maximum allowable limits of vegetable or ginseng beverage described in the Korean Food Standard Codex while their 95th percentile concentrations were below than the guideline for them. None of 33 pesticides was detected in 155 decoction samples, and only one sample showed over limit of detection for residual sulfites. This study support that the contained status of toxic heavy metals, pesticides and sulfur dioxide in herbal decoctions are currently within safe level in Korea, and provide a reference data for the further studies focused on the safety herbal preparations.

  20. Apparatus and method for rapid detection of explosives residue from the deflagration signature thereof

    Science.gov (United States)

    Funsten, H.O.; McComas, D.J.

    1999-06-15

    Apparatus and method are disclosed for rapid detection of explosives residue from the deflagration signature thereof. A property inherent to most explosives is their stickiness, resulting in a strong tendency of explosive particulate to contaminate the environment of a bulk explosive. An apparatus for collection of residue particulate, burning the collected particulate, and measurement of the ultraviolet emission produced thereby, is described. The present invention can be utilized for real-time screening of personnel, cars, packages, suspected devices, etc., and provides an inexpensive, portable, and noninvasive means for detecting explosives. 4 figs.

  1. Monitoring, exposure and risk assessment of sulfur dioxide residues in fresh or dried fruits and vegetables in China.

    Science.gov (United States)

    Lou, Tiantian; Huang, Weisu; Wu, Xiaodan; Wang, Mengmeng; Zhou, Liying; Lu, Baiyi; Zheng, Lufei; Hu, Yinzhou

    2017-06-01

    Sulfur dioxide residues in 20 kinds of products collected from 23 provinces of China (Jilin, Beijing, Shanxi, Shandong, Henan, Hebei, Jiangsu, Anhui, Shanghai, Zhejiang, Fujian, Guangdong, Guangxi, Yunnan, Guizhou, Hunan, Hubei, Chongqing, Sichuan, Gansu, Neimenggu, Xinjiang and Hainan) were analysed, and a health risk assessment was performed. The detection rates of sulfur dioxide residues in fresh vegetables, fresh fruits, dried vegetables and dried fruits were 11.1-95.9%, 12.6-92.3%, 70.3-80.0% and 26.0-100.0%, respectively; the mean concentrations of residues were 2.7-120.8, 3.8-35.7, 26.9-99.1 and 12.0-1120.4 mg kg -1 , respectively. The results indicated that fresh vegetables and dried products are critical products; the daily intakes (EDIs) for children were higher than others; the hazard indexes (HI) for four groups were 0.019-0.033, 0.001-0.005, 0.007-0.016 and 0.002-0.005 at P50, respectively. But the HI was more than 1 at P99 by intake dried fruits and vegetables. Although the risk for consumers was acceptable on the whole, children were the most vulnerable group. Uncertainty and sensitivity analyses indicated that the level of sulfur dioxide residues was the most influential variable in this model. Thus, continuous monitoring and stricter regulation of sulfites using are recommended in China.

  2. Characteristic and principle of the residual stress measurement by neutron diffraction method

    International Nuclear Information System (INIS)

    Akiniwa, Yoshiaki

    2016-01-01

    Although X-ray method has been widely used as the nondestructive measurement method of residual stress, the object to be measured with laboratory X-ray was limited to the vicinity of surface, and the nondestructive measurement of stress inside an essential component could not be performed. Since the neutron method utilizes the wave characteristics of electrically neutral particles, the penetrability is excellent so that information up to the inside of a material can be obtained sufficiently. As the feature of neutron stress measurement, it is suitable for measurement inside metals such as iron and aluminum, which cannot be measured with X-rays. For the measurement of residual stress in localized region, the use of high energy synchrotron radiation is advantageous. In the stress measurement utilizing diffraction phenomena, there is the strain calculated from a change in diffraction lattice spacing. The measured strain is converted into stress using Hooke's Law. As the measurement examples of neutron stress evaluation, the following are introduced: (1) residual stress distribution around the ferrite steel (50 mm thick) welded joint of a large-sized structure, (2) residual stress due to the heat treatment of aluminum alloy with a plate thickness of 20 to 140 mm, and (3) change in the strain of aluminum die block in the vicinity of a cast iron cylinder liner of engine, when heating/cooling up to 470degC. (A.O.)

  3. Vest-over-Pant Method for Closure of Residual Cavity of Liver Hydatid Cyst

    Directory of Open Access Journals (Sweden)

    Saba Behdad

    2012-01-01

    Full Text Available Objective. Although several therapeutic strategies have proven to be effective for hydatid cyst of liver, but surgery is still the most common therapy despite its morbidity and mortality. Furthermore, a variety of technique has been recommended for managing the residual cavity after cystectomy. We report here a new technical method for the reconstruction of hydatid cyst residual cavity with using overlapping flaps of liver edges (Vest over Pant. Methods. In this technique after removing the cyst, the edges of one side of cyst cavity were sutured to the base of the cavity using three to four mattress sutures, and edges of other side of liver was overlapped on the dorsal part of previous layer using four to five mattress sutures. Therefore residual cavity dead space was obliterated with two surfaces of cavity. Results. Fifty males were treated by our method. The average cyst volume was 423±110 mL. There was no intraabdominal sepsis, bile leakage, or hepatic necrosis. In follow-up ultrasound study, residual cavities were disappeared one month after operation. Conclusion. Overlapping flaps of liver edges (Vest over Pant provides easy, safe closure of cyst with preservation of the liver anatomy.

  4. Radiation portal monitor system and method

    Science.gov (United States)

    Morris, Christopher [Los Alamos, NM; Borozdin, Konstantin N [Los Alamos, NM; Green, J Andrew [Los Alamos, NM; Hogan, Gary E [Los Alamos, NM; Makela, Mark F [Los Alamos, NM; Priedhorsky, William C [Los Alamos, NM; Saunders, Alexander [Los Alamos, NM; Schultz, Larry J [Los Alamos, NM; Sossong, Michael J [Los Alamos, NM

    2009-12-15

    A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  5. Biofiltration of composting gases using different municipal solid waste-pruning residue composts: monitoring by using an electronic nose.

    Science.gov (United States)

    López, R; Cabeza, I O; Giráldez, I; Díaz, M J

    2011-09-01

    The concentration of volatile organic compounds (VOCs) during the composting of kitchen waste and pruning residues, and the abatement of VOCs by different compost biofilters was studied. VOCs removal efficiencies greater than 90% were obtained using composts of municipal solid waste (MSW) or MSW-pruning residue as biofilter material. An electronic nose identified qualitative differences among the biofilter output gases at very low concentrations of VOCs. These differences were related to compost constituents, compost particle size (2-7 or 7-20mm), and a combination of both factors. The total concentration of VOCs determined by a photoionization analyser and inferred from electronic nose data sets were correlated over an ample range of concentrations of VOCs, showing that these techniques could be specially adapted for the monitoring of these processes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Geophysical Methods for Monitoring Soil Stabilization Processes

    Science.gov (United States)

    Soil stabilization involves methods used to turn unconsolidated and unstable soil into a stiffer, consolidated medium that could support engineered structures, alter permeability, change subsurface flow, or immobilize contamination through mineral precipitation. Among the variety...

  7. Structural health monitoring system/method using electroactive polymer fibers

    Science.gov (United States)

    Scott-Carnell, Lisa A. (Inventor); Siochi, Emilie J. (Inventor)

    2013-01-01

    A method for monitoring the structural health of a structure of interest by coupling one or more electroactive polymer fibers to the structure and monitoring the electroactive responses of the polymer fiber(s). Load changes that are experienced by the structure cause changes in the baseline responses of the polymer fiber(s). A system for monitoring the structural health of the structure is also provided.

  8. Insecticide residue monitoring in sediments water fish and mangroves at the Cimanuk Delta

    International Nuclear Information System (INIS)

    Sumatra, Made

    1982-01-01

    The water and sediments from the upper stream of Cimanuk river carry insecticide residues especially during the rainy season. The insecticides are deposited in the estuary of Cimanuk river and along the coast of Cimanuk delta. The insecticide residues found at the delta were diazinon thiodan DDE o p-DDT and p p-DDT. Those insecticides are found in most of the water sediments and mangrove leaves samples and some of fishes samples. The samples were taken from the river the estuary the sea, the tambaks, the coast line, and from paddy field. No insecticide residue is found in the water samples taken in the dry season but they are found in the sediment samples taken in both the dry and rainy season. Generally the diazinon residues are higher at the surface than at 0.5m depth in compact sediment but they are higher at 0.5m depth than at the surface of the mud from the coast line. Diazinon and thiodan are found only in three fish samples out of twenty samples analyzed but thiodan is found in almost all of the sediment and mangrove leaves samples. DDT is found in almost all of the samples analyzed. (author)

  9. Stability of PCR Targets for Monitoring Minimal Residual Disease in Neuroblastoma

    NARCIS (Netherlands)

    Stutterheim, Janine; Zappeij-Kannegieter, Lily; Ora, Ingrid; van Sluis, Peter G.; Bras, Johannes; den Ouden, Emmy; Versteeg, Rogier; Caron, Huib N.; van der Schoot, C. Ellen; Tytgat, Godelieve A. M.

    2012-01-01

    In neuroblastoma (NB) patients, minimal residual disease (MRD) can be detected by real-time quantitative PCR (qPCR) using NB-specific target genes, such as PHOX2B and TH. However, it is unknown whether the mRNA levels of these targets vary either during treatment or at relapse. If marker genes are

  10. Residual stress evaluation in the vicinity of ceramic coating interface using polychromatic X-ray method

    Energy Technology Data Exchange (ETDEWEB)

    Shibano, Jun-ichi; Ukai, Takayoshi; Tadano, Shigeru [Hokkaido Univ., Sapporo (Japan). Faculty of Engineering; Todoh, Masahiro

    1995-06-01

    This paper presents a polychromatic X-ray method for nondestructive evaluation of residual stress distributed in the vicinity of the interface between a ceramic coating layer and a substrate metal. Since the strain is assumed to be a linear function of the depth, the strain distribution along the depth direction can be obtained from the weighted mean strain equation calculated by considering the intensity of diffracted X-rays over the penetration depth. Therefore, the distribution along the depth direction of the residual stress was determined by the strain distributions in two directions: the vertical direction and the inclined direction to the surface. SUS316 coated with TiN by the PVD process was used as the specimen. The residual stress distributions in the coating layer and the substrate of the specimen were evaluated using this method. As a result, not only compressive residual stress in the coating layer but also the stress gradient in the substrate could be confirmed simultaneously and nondestructively. (author).

  11. Reliability residual-life prediction method for thermal aging based on performance degradation

    International Nuclear Information System (INIS)

    Ren Shuhong; Xue Fei; Yu Weiwei; Ti Wenxin; Liu Xiaotian

    2013-01-01

    The paper makes the study of the nuclear power plant main pipeline. The residual-life of the main pipeline that failed due to thermal aging has been studied by the use of performance degradation theory and Bayesian updating methods. Firstly, the thermal aging impact property degradation process of the main pipeline austenitic stainless steel has been analyzed by the accelerated thermal aging test data. Then, the thermal aging residual-life prediction model based on the impact property degradation data is built by Bayesian updating methods. Finally, these models are applied in practical situations. It is shown that the proposed methods are feasible and the prediction accuracy meets the needs of the project. Also, it provides a foundation for the scientific management of aging management of the main pipeline. (authors)

  12. A Straight-Line Method for Analyzing Residual Drawdowns at an Observation Well

    Directory of Open Access Journals (Sweden)

    Mesut Çimen

    2015-01-01

    Full Text Available Determination of the hydraulic parameters (transmissivity and storage coefficients of a confined aquifer is important for effective groundwater resources. For this purpose, the residual drawdowns have been in use to estimate the aquifer parameters by the classical Theis recovery method. The proposed method of this paper depends on a straight-line through the field data and it helps to calculate the parameters quickly without any need for long-term pumping data. It is based on the expansion series of the Theis well function by consideration of three terms, and this approach is valid for the dimensionless time factor u′=S′r2/4Tt′≤0.2. The method can be applied reliably to extensive and homogeneous confined aquifers resulting in different storage coefficients during the pumping and recovery periods S≠S′. It presents a strength methodology for the parameters decision making from the residual data in the groundwater field of civil engineering.

  13. Development of Radiometric and Allied Analytical Methods and Strategies to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues. Final Report of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2016-08-01

    Awareness of food safety is rising among consumers, and many importing countries implement food control regulations to guarantee the quality and safety of imported foods for their consumers. Many developing countries have also taken steps to put in place control systems that encourage responsible use of veterinary medicines to combat possible drug resistance, control drug residues and ensure compliance with international and national standards. However, these countries still require the necessary know-how and skills to protect local consumers and to access international markets. One significant constraint is the capacity of laboratory services to generate surveillance data using reliable and cost effective analytical methods validated to national and international standards. The IAEA coordinated research project (CRP) on the Development of Radiometric and Allied Analytical Methods to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues was initiated in 2009 to conduct work on robust nuclear and related technologies suitable for the screening and confirmatory analysis of residues of veterinary medicines, including antimicrobials and anthelmintics commonly used in animal production, with public health and trade significance. The CRP also explored mechanisms to enhance networking among research institutions involved in research on pharmacologically active veterinary drug residues in food (primarily) and environmental samples. The project was implemented by the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture between 2009 and 2014 and involved eleven research contracts and one technical contract, five research agreements and one institution. The CRP was a continuation of the CRP on the Development of Strategies for the Effective Monitoring of Veterinary Drug Residues in Livestock and Livestock Products in Developing Countries and the key findings are also summarized in this publication.

  14. [Development of analytical methods for residual N-methyl carbamate pesticides in foods].

    Science.gov (United States)

    Goto, Tomomi

    2010-08-01

    One of the major roles of public health agencies is to ensure safe products for consumers through analysis of residual agricultural chemicals and veterinary drugs in foods. The use of agricultural chemicals and veterinary drugs in agriculture is necessary to improve the quality of the food produced. They play a beneficial role in providing a plentiful, low-cost supply of high-quality food. On the other hand, as a consequence of this use, the presence of residues in food that is a critical element of overall public health is unavoidable, and residues in food are of great importance in the evaluation of food quality. N-methyl carbamate pesticides have anticholinesterase activity and are used worldwide. The postcolumn HPLC method is widely used for the detection of N-methyl carbamate pesticides in food. However, this traditional method involves a time-consuming process that requires skillful techniques. Therefore we developed a new analysis method for N-methyl carbamate pesticides as described in detail in this paper. The new method, including sample preparation and determination, is simple and rapid and allows simultaneous determination of pesticides in food within a much shorter analysis time as compared with the traditional method. This should provide high-quality analysis and ensure safe products for consumers.

  15. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  16. Development of an analytical method for determination of sulfonamide residues in eggs

    International Nuclear Information System (INIS)

    Ben Azzeddine, Chams

    2009-01-01

    For the determination of sulfonamide residues in eggs, Premitest is selected for screening, providing a qualitative biological approach, it is inexpensive, fast, multi-elements and easy to implement. The H. P.L.C. / UV is the quantitative method of choice for confirmation and determination of these contaminants. During my internship, I had the opportunity to participate in the development of this method. It is recognized slower and more expensive but more specific and more sensitive. In this report, I present this optimized method and some criteria checked during my internship. Other criteria are to be completed to validate the method that will be subsequently used for routine analysis.

  17. Application of the bead flush method to welded pipes to evaluate residual stresses nondestructively

    International Nuclear Information System (INIS)

    Nakamura, H.; Yamamoto, M.

    2002-01-01

    To assess the structural integrity of welded structures during the design and in-service inspection, it is important to evaluate welding residual stresses. Recently, the design process of structures has shifted from 'the design by rule' to 'the design by analysis' using the FEM (finite element method) codes. As the design process advances, analytical processes have formed a link in the chain of manufacturing and in-service inspection procedures. Under this circumstance, authors have proposed a new method called 'the Bead Flush Method', to evaluate the welding residual stresses by utilizing the FEM data constructed during the structural design. In this method, eigenstrains as sources of residual stresses are calculated from released elastic strains after removal of reinforcement of the weld by applying the inverse analysis. Then, residual stresses as well as displacements at any location concerned are evaluated by imposing eigenstrains as initial strains in the FEM analysis. Mechanical properties required through this analysis are the elastic constants at room temperature. No further properties, such as temperature dependencies of the yield strength and the thermal coefficient, are needed. By now, we have confirmed its utility for welded plates by computer simulations and experiments. In this study, further development of this method for application to welded pipes was attempted. Despite its relatively simple shape of pipes (axe symmetrical) compared with welded plates (3-dimentional), welded pipe problems are more complicated than those of welded plates from a view point of the inverse analysis. As a first step, a basic formulization was attempted to overcome this difficulty and future problems to be solved were made clear. Then computer simulations of the bead flush method conducted for a thin walled welded pipe confirmed its utility. Refs. 2 (author)

  18. Optical Performance Monitoring using Proactive Monitoring and the Time Caliper Method

    Science.gov (United States)

    Luk, Hon Tung

    link-based physical layer monitoring, we propose the Time Caliper Method for the relative delay measurement. Two pulse trains with slightly different time period are injected to two subchannels of the multiplexing system. By calculating time alignment shifting of the pulse trains before and after passing through the fiber/device under test, the relative delay can be derived. The Time Caliper Method is experimentally demonstrated on the chromatic dispersion measurement and polarization mode dispersion measurement. Because of the high accuracy requirement of polarization mode dispersion measurement, a novel measurement system is specially designed with an arbitrary waveform generator and a time demultiplexer so that two pulse trains with very small period difference can be generated. Thus the accuracy of the Time Caliper Method can be improved. This thesis briefly reviews the concept and goals for performance monitoring. Proactive monitoring is effective in reducing monitoring time in dynamic reconfigurable network. A reduction of 70%-77% can be achieved compared to the case without proactive monitoring. The cost for proactive monitoring can be reduced by optimizing the monitoring schemes and monitor placement in static networks. By considering the edge overlapping cases and node overlapping cases, the cost can be further reduced. We also propose the Time Caliper Method for relative delay measurement that belongs to link-based physical layer monitoring. The accuracy of the Time Caliper Method depends on the period difference of the two periodic pulse trains used in the measurement. By proposing a novel method to generate two periodic pulse trains that have period difference of 0.1 ps, the Time Caliper Method is capable of measuring chromatic dispersion and polarization mode dispersion with high accuracy.

  19. Apparatus, system, and method for traffic monitoring

    KAUST Repository

    Claudel, Christian G.

    2016-08-25

    An apparatus, system, and method for traffic monitory can have a Lagrangian inertial measurement unit. The Lagrangian inertial measurement unit can have a processor, an accelerometer, a gyroscope, and/or a wireless transmitter. The processor can have an integrated direction cosine matrix. The accelerometer can be configured to measure linear accelerations of a vehicle and/or can communicate measured linear acceleration to the processor. The gyroscope can be configured to measure rotational accelerations of the vehicle and/or can communicate measured rotational acceleration to the processor. The processor can be configured to calculate estimated vehicle speed and/or estimated vehicle attitude. The wireless transmitter can be configured to wirelessly transmit estimated vehicle speed and/or estimated vehicle attitude. The apparatus, system, and method can be integrated with a wireless sensor network.

  20. Spring Chinook Salmon Interactions Indices and Residual/Precocious Male Monitoring in the Upper Yakima Basin; Yakima/Klickitat Fisheries Project Monitoring and Evaluation, 2004-2005 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Pearsons, Todd N.; Johnson, Christopher L. (Washington Department of Fish and Wildlife, Olympia, WA); James, Brenda B. (Cascade Aquatics, Ellensburg, WA)

    2005-05-01

    interpret why supplementation is working or not working (Busack et al. 1997). Monitoring ecological interactions will be accomplished using interactions indices. Interactions indices will be used to index the availability of prey and competition for food and space. The tasks described below represent various subject areas of juvenile spring chinook salmon monitoring but are treated together because they can be accomplished using similar methods and are therefore more cost efficient than if treated separately. Topics of investigation we pursued in this work were: (1) strong interactor monitoring (competition index and prey index), (2) carrying capacity monitoring (microhabitat monitoring); (3) residual and precocious male salmon monitoring (abundance); (4) performance of growth modulation in reducing precocious males during spawning; (5) incidence of predation by residualized chinook salmon; and (6) benefits of salmon carcasses to juvenile salmonids. This report is organized into six chapters to represent these topics of investigation. Data were collected during the summer and fall, 2004 in index sections of the upper Yakima Basin (Figure 1). Previous results on the topics in this report were reported in James et al. (1999), and Pearsons et al. (2003; 2004). Hatchery-reared spring chinook salmon were first released during the spring of 1999. The monitoring plan for the Yakima/Klickitat Fisheries Project calls for the continued monitoring of the variables covered in this report. All findings in this report should be considered preliminary and subject to further revision as more data and analytical results become available.

  1. Wind Turbine Gearbox Condition Monitoring with AAKR and Moving Window Statistic Methods

    Directory of Open Access Journals (Sweden)

    Peng Guo

    2011-11-01

    Full Text Available Condition Monitoring (CM of wind turbines can greatly reduce the maintenance costs for wind farms, especially for offshore wind farms. A new condition monitoring method for a wind turbine gearbox using temperature trend analysis is proposed. Autoassociative Kernel Regression (AAKR is used to construct the normal behavior model of the gearbox temperature. With a proper construction of the memory matrix, the AAKR model can cover the normal working space for the gearbox. When the gearbox has an incipient failure, the residuals between AAKR model estimates and the measurement temperature will become significant. A moving window statistical method is used to detect the changes of the residual mean value and standard deviation in a timely manner. When one of these parameters exceeds predefined thresholds, an incipient failure is flagged. In order to simulate the gearbox fault, manual temperature drift is added to the initial Supervisory Control and Data Acquisitions (SCADA data. Analysis of simulated gearbox failures shows that the new condition monitoring method is effective.

  2. System And Method For Monitoring Traffic While Preserving Personal Privacy

    KAUST Repository

    Canepa, Edward

    2015-08-06

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  3. Systems and method for lagrangian monitoring of flooding conditions

    KAUST Repository

    Claudel, Christian G.

    2015-12-17

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  4. Prediction method of seismic residual deformation of caisson quay wall in liquefied foundation

    Science.gov (United States)

    Wang, Li-Yan; Liu, Han-Long; Jiang, Peng-Ming; Chen, Xiang-Xiang

    2011-03-01

    The multi-spring shear mechanism plastic model in this paper is defined in strain space to simulate pore pressure generation and development in sands under cyclic loading and undrained conditions, and the rotation of principal stresses can also be simulated by the model with cyclic behavior of anisotropic consolidated sands. Seismic residual deformations of typical caisson quay walls under different engineering situations are analyzed in detail by the plastic model, and then an index of liquefaction extent is applied to describe the regularity of seismic residual deformation of caisson quay wall top under different engineering situations. Some correlated prediction formulas are derived from the results of regression analysis between seismic residual deformation of quay wall top and extent of liquefaction in the relative safety backfill sand site. Finally, the rationality and the reliability of the prediction methods are validated by test results of a 120 g-centrifuge shaking table, and the comparisons show that some reliable seismic residual deformation of caisson quay can be predicted by appropriate prediction formulas and appropriate index of liquefaction extent.

  5. Analysis of macro and micro residual stresses in functionally graded materials by diffraction methods

    CERN Document Server

    Dantz, D; Reimers, W

    1999-01-01

    The residual stress state in microwave sintered metal-ceramic functionally graded materials (FGM) consisting of 8Y-ZrO/sub 2//Ni and 8Y-ZrO/sub 2//NiCr8020, respectively, was analysed by non- destructive diffraction methods. In $9 order to get knowledge of the complete residual stress state in the near surface region as well as in the interior of the material, complementary methods were applied. Whereas the surface was characterised by X-ray techniques using $9 conventional sources, the stresses within the bulk of the material were investigated by means of high energy synchrotron radiation. The stress state was found to obey the differences in the coefficients of thermal expansion $9 (micro-stresses) on the one hand and the inhomogeneous cooling conditions (macrostresses) on the other hand. (7 refs).

  6. The MESERAN Method: Rapid Quantification of Non-Volatile Organic Residue (NVOR)

    Energy Technology Data Exchange (ETDEWEB)

    Benkovich, M.G.

    2002-06-13

    The precision analytical technique known as MESERAN Analysis permits quantitative measurement of the level of preexisting nonvolatile organic residue (NVOR) on a substrate from <1 nanogram (ng)/cm{sup 2} to > 100 micrograms ({micro}g)/cm{sup 2} in 2 minutes. MESERAN Analysis is also applicable to determining NVOR in solvents and solvent extracts. The MESERAN method is able to quantify organic contamination levels down to and below 1 ng by depositing as little as 10 microliters ({micro}L) of solvent containing a known amount of contamination on a clean substrate, allowing it to evaporate, and measuring the evaporated residue. The method will be described in detail and NVOR measurements determined from MESERAN data will be presented.

  7. Methods to Reduce Forest Residue Volume after Timber Harvesting and Produce Black Carbon

    Directory of Open Access Journals (Sweden)

    Deborah S. Page-Dumroese

    2017-01-01

    Full Text Available Forest restoration often includes thinning to reduce tree density and improve ecosystem processes and function while also reducing the risk of wildfire or insect and disease outbreaks. However, one drawback of these restoration treatments is that slash is often burned in piles that may damage the soil and require further restoration activities. Pile burning is currently used on many forest sites as the preferred method for residue disposal because piles can be burned at various times of the year and are usually more controlled than broadcast burns. In many cases, fire can be beneficial to site conditions and soil properties, but slash piles, with a large concentration of wood, needles, forest floor, and sometimes mineral soil, can cause long-term damage. We describe several alternative methods for reducing nonmerchantable forest residues that will help remove excess woody biomass, minimize detrimental soil impacts, and create charcoal for improving soil organic matter and carbon sequestration.

  8. Packet flow monitoring tool and method

    Science.gov (United States)

    Thiede, David R [Richland, WA

    2009-07-14

    A system and method for converting packet streams into session summaries. Session summaries are a group of packets each having a common source and destination internet protocol (IP) address, and, if present in the packets, common ports. The system first captures packets from a transport layer of a network of computer systems, then decodes the packets captured to determine the destination IP address and the source IP address. The system then identifies packets having common destination IP addresses and source IP addresses, then writes the decoded packets to an allocated memory structure as session summaries in a queue.

  9. Electrochemical methods for monitoring of environmental carcinogens.

    Science.gov (United States)

    Barek, J; Cvacka, J; Muck, A; Quaiserová, V; Zima, J

    2001-04-01

    The use of modern electroanalytical techniques, namely differential pulse polarography, differential pulse voltammetry on hanging mercury drop electrode or carbon paste electrode, adsorptive stripping voltammetry and high performance liquid chromatography with electrochemical detection for the determination of trace amounts of carcinogenic N-nitroso compounds, azo compounds, heterocyclic compounds, nitrated polycyclic aromatic hydrocarbons and aromatic and heterocyclic amines is discussed. Scope and limitations of these methods are described and some practical applications based on their combination with liquid-liquid or solid phase extraction are given.

  10. Multivariate Statistical Process Control Process Monitoring Methods and Applications

    CERN Document Server

    Ge, Zhiqiang

    2013-01-01

      Given their key position in the process control industry, process monitoring techniques have been extensively investigated by industrial practitioners and academic control researchers. Multivariate statistical process control (MSPC) is one of the most popular data-based methods for process monitoring and is widely used in various industrial areas. Effective routines for process monitoring can help operators run industrial processes efficiently at the same time as maintaining high product quality. Multivariate Statistical Process Control reviews the developments and improvements that have been made to MSPC over the last decade, and goes on to propose a series of new MSPC-based approaches for complex process monitoring. These new methods are demonstrated in several case studies from the chemical, biological, and semiconductor industrial areas.   Control and process engineers, and academic researchers in the process monitoring, process control and fault detection and isolation (FDI) disciplines will be inter...

  11. Shifted Legendre method with residual error estimation for delay linear Fredholm integro-differential equations

    Directory of Open Access Journals (Sweden)

    Şuayip Yüzbaşı

    2017-03-01

    Full Text Available In this paper, we suggest a matrix method for obtaining the approximate solutions of the delay linear Fredholm integro-differential equations with constant coefficients using the shifted Legendre polynomials. The problem is considered with mixed conditions. Using the required matrix operations, the delay linear Fredholm integro-differential equation is transformed into a matrix equation. Additionally, error analysis for the method is presented using the residual function. Illustrative examples are given to demonstrate the efficiency of the method. The results obtained in this study are compared with the known results.

  12. Application and evaluation of a high-resolution mass spectrometry screening method for veterinary drug residues in incurred fish and imported aquaculture samples.

    Science.gov (United States)

    Turnipseed, Sherri B; Storey, Joseph M; Wu, I-Lin; Gieseker, Charles M; Hasbrouck, Nicholas R; Crosby, Tina C; Andersen, Wendy C; Lanier, Shanae; Casey, Christine R; Burger, Robert; Madson, Mark R

    2018-02-14

    The ability to detect chemical contaminants, including veterinary drug residues in animal products such as fish, is an important example of food safety analysis. In this paper, a liquid chromatography high-resolution mass spectrometry (LC-HRMS) screening method using a quadrupole-Orbitrap instrument was applied to the analysis of veterinary drug residues in incurred tissues from aquacultured channel catfish, rainbow trout, and Atlantic salmon and imported aquacultured products including European eel, yellow croaker, and tilapia. Compared to traditional MS methods, the use of HRMS with nontargeted data acquisition and exact mass measurement capability greatly increased the scope of compounds that could be monitored simultaneously. The fish samples were prepared for analysis using a simple efficient procedure that consisted of an acidic acetonitrile extraction followed by solid phase extraction cleanup. Two different HRMS acquisition programs were used to analyze the fish extracts. This method detected and identified veterinary drugs including quinolones, fluoroquinolones, avermectins, dyes, and aminopenicillins at residue levels in fish that had been dosed with those compounds. A metabolite of amoxicillin, amoxicillin diketone, was also found at high levels in catfish, trout, and salmon. The method was also used to characterize drug residues in imported fish. In addition to confirming findings of fluoroquinolone and sulfonamide residues that were found by traditional targeted MS methods, several new compounds including 2-amino mebendazole in eel and ofloxacin in croaker were detected and identified. Graphical Abstract Aquacultured samples are analyzed with a high-resolution mass spectrometry screening method to detect and identify unusual veterinary drug residues including ofloxacin in an imported fish.

  13. RANDOM FUNCTIONS AND INTERVAL METHOD FOR PREDICTING THE RESIDUAL RESOURCE OF BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    Shmelev Gennadiy Dmitrievich

    2017-11-01

    Full Text Available Subject: possibility of using random functions and interval prediction method for estimating the residual life of building structures in the currently used buildings. Research objectives: coordination of ranges of values to develop predictions and random functions that characterize the processes being predicted. Materials and methods: when performing this research, the method of random functions and the method of interval prediction were used. Results: in the course of this work, the basic properties of random functions, including the properties of families of random functions, are studied. The coordination of time-varying impacts and loads on building structures is considered from the viewpoint of their influence on structures and representation of the structures’ behavior in the form of random functions. Several models of random functions are proposed for predicting individual parameters of structures. For each of the proposed models, its scope of application is defined. The article notes that the considered approach of forecasting has been used many times at various sites. In addition, the available results allowed the authors to develop a methodology for assessing the technical condition and residual life of building structures for the currently used facilities. Conclusions: we studied the possibility of using random functions and processes for the purposes of forecasting the residual service lives of structures in buildings and engineering constructions. We considered the possibility of using an interval forecasting approach to estimate changes in defining parameters of building structures and their technical condition. A comprehensive technique for forecasting the residual life of building structures using the interval approach is proposed.

  14. Persistence of organophosphorus pesticides in aquatic environments. Coordinated programme on isotope-tracer-aided research and monitoring on agricultural residue - biological interactions in aquatic environment

    International Nuclear Information System (INIS)

    Horvath, L.

    1982-08-01

    A radiometric enzymic assay method was developed for quick measuring of organophosphorous insecticides in water samples. All steps of the assay procedure were carried out in scintillation vials. 50 μl enzyme solution (acetylcholinesterase of electric eel) and 50 μl buffer pH 7 were pipetted into the vial followed by 100 μl of water sample or aqueous solution of the insecticide and the mixture was incubated for 60 minutes. 50 μl 3 H-acetylcholine were added to the vial and the enzymic reaction stopped after 10 minutes by adding 200 μl buffer solution pH 2.5. 10 ml scintillation cocktail were then added and after shaking and 30 minutes standing the radioactivity was determined in a liquid scintillation spectrometer. Acetylcholine remained in the water phase while 3 H-acetic acid released in enzymic hydrolysis may be extracted by an organic solvent. By this method, not only the parent compound but also some of its degradation products, which possess some anticholinesteratic activity can be measured. The method is suitable for combination with thin-layer chromatography for identification purposes. Using this method, we studied the degradation of the organophosphorous insecticides malathion, parathion, DDVP and imidan. The degradation in distilled water and natural water was compared. For example, the half-time of malathion in distilled water at room temperature was 6 days while in natural water (Danube river) it was 4 hours. The degradation processes were also studied in model systems containing sediment and water. Degradation was faster in models containing solid particles than in filtered water. The radiometric enzymic method was tested as analytical procedure for residue monitoring. Since 1978 a residue monitoring programme was in progress in the Danube river near Budapest. Occasionally high residue levels were detected in spring and early summer. The radiometric enzymic method has proved to be a useful analytical method for anticholinesterase pesticides in

  15. Validation of methods used in the Florida Department of Agricultural and Consumer Services' Chemical Residue Laboratory.

    Science.gov (United States)

    Parker, G A

    1991-01-01

    Very few methods for detecting residues of pesticides in food or agricultural samples have undergone rigorous colloborative study and possess official AOAC status. The Chemical Residue Laboratory has formalized a method validation scheme to use when incorporating or developing new, unofficial methods. These methods are validated by assessing certain performance parameters: scope, specificity, linear range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). For accuracy and precision assessment, 12 replicate fortifications must yield recoveries within the range of 70-120% with a coefficient of variation (CV) that compares favorably to the Horwitz CV. LOD and LOQ are equivalent to 3 and 10 times, respectively, the background signal contributed by a sample matrix blank. This criterion that we use for LOD/LOQ is not universal. In fact, because of differing definitions, we have encountered difficulties in enforcing a tolerance by using a registrant's method. This paper also presents an example of our method validation scheme, using a recent method development project for detecting sulfamethazine in raw milk. The sulfamethazine project also revealed unanticipated personnel problems, underscoring the importance of the human factor in quality assurance.

  16. [Comparison of pretreatment methods for the simultaneous determination of diclazuril and toltrazuril residues in chicken tissues].

    Science.gov (United States)

    Shi, Zuhao; Ge, Qinglian; Lu, Junxian; Liu, Xuexian; Gong, Jiansen; Zhu, Liangqiang; Qi, Kezong; Chen, Dingding; Peng, Kaisong

    2009-05-01

    The effects of four pretreatment methods (acetonitrile extraction-evaporation concentration, acetonitrile extraction-solid phase extraction (SPE), matrix solid-phase dispersion (MSPD) extraction and MSPD-SPE) for the simultaneous analysis of diclazuril and toltrazuril residues in chicken tissues were compared. The average recovery of 70% for the former three methods as achieved. In comparison with other methods, the MSPD method saved more than 60% in time and solvent. So, MSPD as the sample pretreatment method, an MSPD-high performance liquid chromatography with ultraviolet detection (MSPD-HPLC/UV) method was established for the analysis. Under the optimal chromatographic conditions, the linear range was between 50 and 1,000 microg/kg. At the added levels of 50, 500, 1,000 ng/g, the recoveries of diclazuril and toltrazuril in chicken tissues ranged from 71.13% - 84.02% with the relative standard deviations (RSD) in the range of 3.76% - 12.11%, and the RSDs of intra- and interday analyses ranged from 3.70% - 6.77%. The detection limits of diclazuril and toltrazuril were less than 10 microg/kg. The quantitative limits of diclazuril and toltrazuril were less than 20 microg/kg. The method meet the requirements of the residue analysis on accuracy and precision.

  17. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  18. Spring Chinook Salmon Interactions Indices and Residual/Precocial Monitoring in the Upper Yakima Basin; Yakima/Klickitat Fisheries Project Monitoring and Evaluation Report 5 of 7, 2003-2004 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Pearsons, Todd N.; Johnson, Christopher L.; James, Brenda B. (Washington Department of Fish and Wildlife, Olympia, WA)

    2004-05-01

    is working or not working (Busack et al. 1997). Monitoring ecological interactions will be accomplished using interactions indices. Interactions indices will be used to index the availability of prey and competition for food and space. The tasks described below represent various subject areas of juvenile spring chinook salmon monitoring but are treated together because they can be accomplished using similar methods and are therefore more cost efficient than if treated separately. Three areas of investigation we pursued in this work were: (1) strong interactor monitoring (competition index and prey index), (2) carrying capacity monitoring (microhabitat monitoring); (3) residual and precocial salmon monitoring (abundance). This report is organized into three chapters to represent these three areas of investigation. Data were collected during the summer and fall, 2003 in index sections of the upper Yakima Basin (Figure 1). Previous results on the topics in this report were reported in James et al. (1999), and Pearsons et al. (2003). Hatchery-reared spring chinook salmon were first released during the spring of 1999. The monitoring plan for the Yakima/Klickitat Fisheries Project calls for the continued monitoring of the variables covered in this report. All findings in this report should be considered preliminary and subject to further revision as more data and analytical results become available.

  19. Application of Scharer's quantitative method for the determination of residual alkaline phosphatase activity in standard Minas

    Directory of Open Access Journals (Sweden)

    C.F. Soares

    2013-08-01

    Full Text Available Milk pasteurization is a critical issue in the dairy industry, and failures in this process can affect final product safety. Scharer's enzymatic method is still traditionally used to verify pasteurization efficiency compliance, and it is based on screening for residual alkaline phosphatase in milk. Although several methods are used to quantify enzymatic activity to assess milk pasteurization efficiency, there is a small amount of published data regarding the use of these methods to quantify alkaline phosphatase in cheese. In this study, the Scharer's modified method was used to determine the levels of residual alkaline phosphatase in standard minas cheese, before and after 20 days of ripening. The cheeses were made using raw or pasteurized milk with the addition of different concentrations of raw milk (0; 0.05%; 0.10%; 0.20%; and 0.50%. In the fresh cheese samples, the method showed a sensitivity of only 0.50% with the addition of raw milk to the pasteurized milk used to make cheese. In addition, levels of up 0.20% of raw milk in pasteurized milk, the concentrations of phenol was inferior to 1μg phenol/g of dairy product which is the preconized indicator value for adequate pasteurization.

  20. Quantitative determination of pefloxacin mesylate by residual-base neutralisation method

    Directory of Open Access Journals (Sweden)

    HULIKALCHANDRA SHEKAR PRAMEELA

    2004-05-01

    Full Text Available This work describes two procedures based on residual base determination for the quantification of pefloxacin mesylate (PFM in bulk drug and in pharmaceutical products. In the first method involving titrimetry, the drug solution is treated with a measured excess of sodium hydroxide followed by back titration of the residual base with hydrochloric acid using a phenol red-bromothymol blue mixed indicator. The second spectrophotometrie method involves treatment of a fixed amount of sodium hydroxide – phenol red mixture with varying amounts of the drug, and measuring the decrease in the absorbance of the dye at 560 nm. In the titrimetric method, a reaction stoichiometry of 1:1 was found in the quantification range of 4–20 mg of drug. The spectrophotometric method allows the determination of PFM in the 5–40 mg ml-1 range. The molar absorptivity is 5.91¤103 l mol-1 cm-1 and the Sandell sensitivity is 56.37 ng cm-2. The methods were applied successfully to the determination of PFM in pharmaceutical preparations.

  1. Method and apparatus for monitoring two-phase flow. [PWR

    Science.gov (United States)

    Sheppard, J.D.; Tong, L.S.

    1975-12-19

    A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.

  2. An online substructure identification method for local structural health monitoring

    International Nuclear Information System (INIS)

    Hou, Jilin; Ou, Jinping; Jankowski, Łukasz

    2013-01-01

    This paper proposes a substructure isolation method, which uses time series of measured local response for online monitoring of substructures. The proposed monitoring process consists of two key steps: construction of the isolated substructure, and its identification. The isolated substructure is an independent virtual structure, which is numerically isolated from the global structure by placing virtual supports on the interface. First, the isolated substructure is constructed by a specific linear combination of time series of its measured local responses. Then, the isolated substructure is identified using its local natural frequencies extracted from the combined responses. The substructure is assumed to be linear; the outside part of the global structure can have any characteristics. The method has no requirements on the initial state of the structure, and so the process can be carried out repetitively for online monitoring. Online isolation and monitoring is illustrated in a numerical example with a frame model, and then verified in a cantilever beam experiment. (paper)

  3. Monitoring methods for dogs and cats with diabetes mellitus.

    Science.gov (United States)

    Cook, Audrey K

    2012-05-01

    Effective monitoring is essential for the management of dogs and cats with diabetes mellitus. However, methods for evaluating glycemic control must be tailored to meet both the needs of the patient and the expectations of the owner. This article discusses the philosophies that drive blood glucose monitoring in veterinary diabetics and review common practices. The advantages and limitations of the various options are presented. © 2012 Diabetes Technology Society.

  4. Monitoring Methods for Dogs and Cats with Diabetes Mellitus

    Science.gov (United States)

    Cook, Audrey K

    2012-01-01

    Effective monitoring is essential for the management of dogs and cats with diabetes mellitus. However, methods for evaluating glycemic control must be tailored to meet both the needs of the patient and the expectations of the owner. This article discusses the philosophies that drive blood glucose monitoring in veterinary diabetics and review common practices. The advantages and limitations of the various options are presented. PMID:22768878

  5. QuEChERS GC-MS validation and monitoring of pesticide residues in different foods in the tomato classification group.

    Science.gov (United States)

    Ramírez Restrepo, Andrés; Gallo Ortiz, Andrés Fernando; Hoyos Ossa, Duvan Esteban; Peñuela Mesa, Gustavo Antonio

    2014-09-01

    The objective of this study was to validate (SANCO/12495/2011 and NTC-ISO/IEC 17025) multi-residue multi-class methods using QuEChERS sample preparation and GC-MS for the analysis of regulated pesticides in tomatoes (Solanum lycopersicum), tamarillos (Solanum betaceum) and goldenberries (Physalis peruviana). These Latin American products are representative and widely produced in Antioquia (Colombia). Sample preparation followed the UNE-EN 15662 method (150 mg MgSO4, 25mg primary secondary amines and 25mg of octadecylsiloxane for cleanup; graphitized carbon black was added for tomatoes). Extracts were injected using a programmed temperature-vaporizing injector. The residues were validated over a range from 0.02 mg/kg to 0.20 mg/kg, with 24 analytes validated in tomatoes, 33 in tamarillos and 28 in goldenberries. An initial risk assessment was enabled by monitoring 24 samples in the municipalities of El Peñol, Marinilla and San Vicente Ferrer. Risks were found for tomatoes, but no significant risks were found for tamarillos or goldenberries. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Spring Chinook Salmon Interactions Indices and Residual/Precocial Monitoring in the Upper Yakima Basin, Annual Report 1998

    International Nuclear Information System (INIS)

    James, Brenda B.; Pearsons, Todd N.; McMichael, Geoffrey A.

    1999-01-01

    Select ecological interactions and spring chinook salmon residual/precocial abundance were monitored in 1998 as part of the Yakima/Klickitat Fisheries Project's supplementation monitoring program. Monitoring these variables is part of an effort to help evaluate the factors that contribute to, or limit supplementation success. The ecological interactions that were monitored were prey consumption, competition for food, and competition for space. The abundance of spring chinook salmon life-history forms that have the potential to be influenced by supplementation and that have important ecological and genetic roles were monitored (residuals and precocials). Residual spring chinook salmon do not migrate to the ocean during the normal emigration period and continue to rear in freshwater. Precocials are those salmon that precocially mature in freshwater. The purpose of sampling during 1998 was to collect baseline data one year prior to the release of hatchery spring chinook salmon which occurred during the spring of 1999. All sampling that the authors report on here was conducted in upper Yakima River during summer and fall 1998. The stomach fullness of juvenile spring chinook salmon during the summer and fall averaged 12%. The food competition index suggested that mountain whitefish (0.59), rainbow trout (0.55), and redside shiner (0.55) were competing for food with spring chinook salmon. The space competition index suggested that rainbow trout (0.31) and redside shiner (0.39) were competing for space with spring chinook salmon but mountain whitefish (0.05) were not. Age-0 spring chinook salmon selected a fairly narrow range of microhabitat parameters in the summer and fall relative to what was available. Mean focal depths and velocities for age 0 spring chinook salmon during the summer were 0.5 m ± 0.2 m and 0.26 m/s ± 0.19 m/s, and during the fall 0.5 m ± 0.2 m and 0.24 m/s ± 0.18 m/s. Among potential competitors, age 1+ rainbow trout exhibited the greatest degree

  7. Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce

    NARCIS (Netherlands)

    Mol, J.G.J.; Rooseboom, A.; Dam, van R.; Roding, M.; Arondeus, K.; Sunarto, S.

    2007-01-01

    The ethyl acetate-based multi-residue method for determination of pesticide residues in produce has been modified for gas chromatographic (GC) analysis by implementation of dispersive solid-phase extraction (using primary¿secondary amine and graphitized carbon black) and large-volume (20 ¿L)

  8. Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce

    NARCIS (Netherlands)

    Mol, H.G.J.; Rooseboom, A.; Dam, R. van; Roding, M.; Arondeus, K.; Sunarto, S.

    2007-01-01

    The ethyl acetate-based multi-residue method for determination of pesticide residues in produce has been modified for gas chromatographic (GC) analysis by implementation of dispersive solid-phase extraction (using primary-secondary amine and graphitized carbon black) and large-volume (20 μL)

  9. A method for assessing residual NAPL based on organic chemical concentrations in soil samples

    International Nuclear Information System (INIS)

    Feenstra, S.; Mackay, D.M.; Cherry, J.A.

    1991-01-01

    Ground water contamination by non-aqueous phase liquid (NAPL) chemicals is a serious concern at many industrial facilities and waste disposal sites. NAPL in the form of immobile residual contamination, or pools of mobile or potentially mobile NAPL, can represent continuing sources of ground water contamination. In order to develop rational and cost-effective plans for remediation of soil and ground water contamination at such sites, it is essential to determine if non-aqueous phase liquid (NAPL) chemicals are present in the subsurface and delineate the zones of NAPL contamination. Qualitatively, soil analyses that exhibit chemical concentrations in the percent range or >10,000 mg/kg would generally be considered to indicate the presence of NAPL. However, the results of soil analyses are seldom used in a quantitative manner to assess the possible presence of residual NAPL contamination when chemical concentrations are lower and the presence of NAPL is not obvious. The assessment of the presence of NAPL in soil samples is possible using the results of chemical and physical analyses of the soil, and the fundamental principles of chemical partitioning in unsaturated or saturated soil. The method requires information on the soil of the type typically considered in ground water contamination studies and provides a simple tool for the investigators of chemical spill and waste disposal sites to assess whether soil chemical analyses indicate the presence of residual NAPL in the subsurface

  10. Monitoring and removal of residual phthalate esters and pharmaceuticals in the drinking water of Kaohsiung City, Taiwan.

    Science.gov (United States)

    Yang, Gordon C C; Yen, Chia-Heng; Wang, Chih-Lung

    2014-07-30

    This study monitored the occurrence and removal efficiencies of 8 phthalate esters (PAEs) and 13 pharmaceuticals present in the drinking water of Kaohsiung City, Taiwan. The simultaneous electrocoagulation and electrofiltration (EC/EF) process was used to remove the contaminants. To this end, a monitoring program was conducted and a novel laboratory-prepared tubular carbon nanofiber/carbon/alumina composite membrane (TCCACM) was incorporated into the EC/EF treatment module (collectively designated as "TCCACM-EC/EF treatment module") to remove the abovementioned compounds from water samples. The monitoring results showed that the concentrations of PAEs were lower in water samples from drinking fountains as compared with tap water samples. No significant differences were found between the concentrations of pharmaceuticals in the two types of water samples. Under optimal operating conditions, the TCCACM-EC/EF treatment module yielded the lowest residual concentrations, ranging from not detected (ND) to 52ng/L for PAEs and pharmaceuticals of concern in the tap water samples. Moreover, the performance of the TCCACM-EC/EF treatment module is comparable with a series of treatment units employed for the drinking fountain water treatment system. The relevant removal mechanisms involved in the TCCACM-EC/EF treatment module were also discussed in this work. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Monitoring and exposure assessment of pesticide residues in cowpea (Vigna unguiculata L. Walp) from five provinces of southern China.

    Science.gov (United States)

    Huan, Zhibo; Xu, Zhi; Luo, Jinhui; Xie, Defang

    2016-11-01

    Residues of 14 pesticides were determined in 150 cowpea samples collected in five southern Chinese provinces in 2013 and 2014.70% samples were detected one or more residues. 61.3% samples were illegal mainly because of detection of unauthorized pesticides. 14.0% samples contained more than three pesticides. Deterministic and probabilistic methods were used to assess the chronic and acute risk of pesticides in cowpea to eight subgroups of people. Deterministic assessment showed that the estimated short-term intakes (ESTIs) of carbofuran were 1199.4%-2621.9% of the acute reference doses (ARfD) while the rates were 985.9%-4114.7% using probabilistic assessment. Probabilistic assessment showed 4.2%-7.8% subjects may suffer from unacceptable acute risk from carbofuran contaminated cowpeas from the five provinces (especially children). But undue concern is not necessary, because all the estimations are based on conservative assumption. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Use of a dynamic grid adaptation in the asymmetric weighted residual method

    International Nuclear Information System (INIS)

    Graf, V.; Romstedt, P.; Werner, W.

    1986-01-01

    A dynamic grid adaptive method has been developed for use with the asymmetric weighted residual method. The method automatically adapts the number and position of the spatial mesh points as the solution of hyperbolic or parabolic vector partial differential equations progresses in time. The mesh selection algorithm is based on the minimization of the L 2 norm of the spatial discretization error. The method permits the accurate calculation of the evolution of inhomogeneities, like wave fronts, shock layers, and other sharp transitions, while generally using a coarse computational grid. The number of required mesh points is significantly reduced, relative to a fixed Eulerian grid. Since the mesh selection algorithm is computationally inexpensive, a corresponding reduction of computing time results

  13. Comparison between some determination methods of residual styrene in plastic scintillators

    International Nuclear Information System (INIS)

    Bezuglyi, V.D.; Ponomarev, Yu.P.; Gunder, O.A.; Biteman, V.B.; Senchishin, V.G.

    1988-01-01

    Scintillators made of plastic materials based on polystyrene with addition of p-terphenyl and 1,4-di-[(2,5-phenyl)oxazolyl] benzene have found wide application principally in the detection of radioactivity. The stability of the scintillating characteristics of these materials depends to great degree on the concentration of the residual monomer and for this reason it is important to have a sufficiently convenient method for the determination of this latter. We investigated the bromometric and acid-base titration methods with visual and potentiometric titration end point detection. We also examined the polarographic methods, direct and indirect, using the electroreduction of the mercury acetate complex of the monomer. We checked the methods on a scintillator sample and on synthetic mixtures, i.e., mixtures of monomer, polymer, and p-terphenyl. We compared the determination results for styrene and showed that the most accurate procedure is the bromometric determination with potentiometric indication of the end-point

  14. Development of an on-site measurement method for residual stress in primary system piping of nuclear power plants

    International Nuclear Information System (INIS)

    Maekawa, Akira; Takahashi, Shigeru; Fujiwara, Masaharu

    2014-01-01

    In residual stress measurement for large-scale pipes and vessels in high radiation areas and highly contaminated areas of nuclear plants, it is difficult to bring the radioactivated pipes and vessels out of the areas as they are. If they can brought out, it is very burdensome to handle them for the measurement. Development of an on-site measurement method of residual stress which can be quickly applied and has sufficient measurement accuracy is desirable. In this study, a new method combining an electric discharge skim-cut method with a microscopic strain measurement method using markers was proposed to realize the on-site residual stress measurement on pipes in high radiation areas and highly contaminated areas. In the electric discharge skim-cut method, a boat-type sample is skimmed out of a pipe outer/inner surface using electric discharge machining and released residual stress is measured. The on-site measurement of residual stress by the method can be done using a small, portable electric discharge machine. In the microscopic strain measurement method using markers, the residual stress is estimated by microscopic measurement of the distance between markers after the stress release. The combination of both methods can evaluate the residual stress with the same accuracy as conventional methods offer and it can achieve reduction of radiation exposure in the measurement because the work is done simply and rapidly. In this study, the applicability of the electric discharge skim-cut method was investigated because the applicability of the microscopic strain measurement method using markers was confirmed previously. The experimental examination clarified the applicable conditions for the residual stress measurement with the same accuracy as the conventional methods. Furthermore, the electric discharge machining conditions using pure water as the machining liquid was found to eliminate the amount of liquid radioactive waste completely. (author)

  15. Monitoring devices and systems for monitoring frequency hopping wireless communications, and related methods

    Science.gov (United States)

    Derr, Kurt W.; Richardson, John G.

    2017-05-02

    Monitoring devices and systems comprise a plurality of data channel modules coupled to processing circuitry. Each data channel module of the plurality of data channel modules is configured to capture wireless communications for a selected frequency channel. The processing circuitry is configured to receive captured wireless communications from the plurality of data channel modules and to organize received wireless communications according to at least one parameter. Related methods of monitoring wireless communications are also disclosed.

  16. Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.

    Science.gov (United States)

    Lehotay, Steven J; Mastovská, Katerina; Yun, Seon Jong

    2005-01-01

    Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.

  17. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  18. A new one-platform flow cytometric method for residual cell counting in platelet concentrates.

    Science.gov (United States)

    Schmidt, Michael; Spengler, Hans-Peter; Lambrecht, Bernd; Hourfar, Michael K; Seifried, Erhard; Tonn, Torsten

    2009-12-01

    According to German regulations and guidelines, residual red blood cells (rRBCs) and residual white blood cells (rWBCs) must number fewer than 3 x 10(9) cells/unit and 1 x 10(6) cells/unit in platelet concentrates (PCs), respectively. Due to low levels of residual cells in final products, there is still a need for fast, reliable, and sensitive methods of automated detection of these cell types. In Part A, 21 PCs were spiked with predetermined numbers of red blood cells (RBCs) and white blood cells (WBCs). The linearity, precision, and accuracy of the BD Thrombo Count assay (BD Biosciences Europe) were tested and validated according to international guidelines. Finally in Part B, 100 PCs prepared from pooled buffy coats were tested by the BD Thrombo Count assay and compared with other methods, including Nageotte (rWBCs) and Neubauer (rRBCs) counting chambers and the flow cytometric BD LeucoCOUNT (Becton Dickinson) assay (rWBCs). The unspecific background of blank PC samples was fewer than 0.02 cells/microL for WBCs and fewer than 34 cells/microL for RBCs (mean, 21). Linear regression and precision analyses of spiked PC samples were determined for both WBCs (r(2) = 0.992; range, 0.6-6.0 WBCs/microL) and RBCs (r(2) = 0.999; 800-8000 RBCs/microL). No carryover of cells or drift in results was detected in the automated sample acquisition mode. Analysis according to statistical methods of Bland and Altman demonstrated a high correlation between BD Thrombo Count and the Neubauer manual counting chamber. This novel flow cytometric test is a quick and reliable single-tube assay that has been demonstrated as a potential alternative for the existing manual microscopic counting procedures that are both time-consuming and laborious.

  19. Evaluation of residual antibacterial potency in antibiotic production wastewater using a real-time quantitative method.

    Science.gov (United States)

    Zhang, Hong; Zhang, Yu; Yang, Min; Liu, Miaomiao

    2015-11-01

    While antibiotic pollution has attracted considerable attention due to its potential in promoting the dissemination of antibiotic resistance genes in the environment, the antibiotic activity of their related substances has been neglected, which may underestimate the environmental impacts of antibiotic wastewater discharge. In this study, a real-time quantitative approach was established to evaluate the residual antibacterial potency of antibiotics and related substances in antibiotic production wastewater (APW) by comparing the growth of a standard bacterial strain (Staphylococcus aureus) in tested water samples with a standard reference substance (e.g. oxytetracycline). Antibiotic equivalent quantity (EQ) was used to express antibacterial potency, which made it possible to assess the contribution of each compound to the antibiotic activity in APW. The real-time quantitative method showed better repeatability (Relative Standard Deviation, RSD 1.08%) compared with the conventional fixed growth time method (RSD 5.62-11.29%). And its quantification limits ranged from 0.20 to 24.00 μg L(-1), depending on the antibiotic. We applied the developed method to analyze the residual potency of water samples from four APW treatment systems, and confirmed a significant contribution from antibiotic transformation products to potent antibacterial activity. Specifically, neospiramycin, a major transformation product of spiramycin, was found to contribute 13.15-22.89% of residual potency in spiramycin production wastewater. In addition, some unknown related substances with antimicrobial activity were indicated in the effluent. This developed approach will be effective for the management of antibacterial potency discharge from antibiotic wastewater and other waste streams.

  20. Residual-based a posteriori error estimation for multipoint flux mixed finite element methods

    KAUST Repository

    Du, Shaohong

    2015-10-26

    A novel residual-type a posteriori error analysis technique is developed for multipoint flux mixed finite element methods for flow in porous media in two or three space dimensions. The derived a posteriori error estimator for the velocity and pressure error in L-norm consists of discretization and quadrature indicators, and is shown to be reliable and efficient. The main tools of analysis are a locally postprocessed approximation to the pressure solution of an auxiliary problem and a quadrature error estimate. Numerical experiments are presented to illustrate the competitive behavior of the estimator.

  1. [Research on rapid and quantitative detection method for organophosphorus pesticide residue].

    Science.gov (United States)

    Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming

    2014-05-01

    The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm

  2. Generation and importance of linked and irreducible moment diagrams in the recursive residue generation method

    International Nuclear Information System (INIS)

    Schek, I.; Wyatt, R.E.

    1986-01-01

    Molecular multiphoton processes are treated in the Recursive Residue Generation Method (A. Nauts and R.E. Wyatt, Phys. Rev. Lett 51, 2238 (1983)) by converting the molecular-field Hamiltonian matrix into tridiagonal form, using the Lanczos equations. In this study, the self-energies (diagonal) and linking (off-diagaonal) terms in the tridiagonal matrix are obtained by comparing linked moment diagrams in both representations. The dynamics of the source state is introduced and computed in terms of the linked and the irreducible moments

  3. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    Science.gov (United States)

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Measuring multiple residual-stress components using the contour method and multiple cuts

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Michael B [Los Alamos National Laboratory; Swenson, Hunter [Los Alamos National Laboratory; Pagliaro, Pierluigi [U. PALERMO; Zuccarello, Bernardo [U. PALERMO

    2009-01-01

    The conventional contour method determines one component of stress over the cross section of a part. The part is cut into two, the contour of the exposed surface is measured, and Bueckner's superposition principle is analytically applied to calculate stresses. In this paper, the contour method is extended to the measurement of multiple stress components by making multiple cuts with subsequent applications of superposition. The theory and limitations are described. The theory is experimentally tested on a 316L stainless steel disk with residual stresses induced by plastically indenting the central portion of the disk. The stress results are validated against independent measurements using neutron diffraction. The theory has implications beyond just multiple cuts. The contour method measurements and calculations for the first cut reveal how the residual stresses have changed throughout the part. Subsequent measurements of partially relaxed stresses by other techniques, such as laboratory x-rays, hole drilling, or neutron or synchrotron diffraction, can be superimposed back to the original state of the body.

  5. Comparative analysis of different methods of extraction of present hydrocarbons in industrial residual waters

    International Nuclear Information System (INIS)

    Santa, Judith Rocio; Serrano, Martin; Stashenko, Elena

    2002-01-01

    A comparison among four extraction techniques such as: liquid - liquid (LLE) continuous and for lots, solid phase extraction (SPE), solid phase micro extraction (SPME) and static headspace (S-HS) was carried out. The main purpose of this research was to determine the highest recovery efficiencies and how reproducible the tests are while varying parameters such as time, extraction technique, type of solvents and others. Chromatographic parameters were optimized in order to carry out the analyses. Hydrocarbon's quantification of residual waters was achieved by using a high-resolution gas chromatography with a gas flame ionization detector (HRGC-FID). Validation of the method was carried out by analyzing real samples taken in different sampling places of the residual waters treatment plant of Ecopetrol - Barrancabermeja. The use of extraction methods that require big solvent quantities and long time for analysis are losing validity day by day. Techniques such as the HS-SPME and static HS are offered as alternatives for quantifying hydrocarbons. They show total lack of solvents, high sensibility, selectivity and the techniques are reproducible. Solid phase micro extraction (SPME) and static headspace (static HS) techniques were chosen as the extraction techniques to validate the method in real samples. Both techniques showed similar results for the determination of total hydrocarbons (in the gasoline range)

  6. Effect of the sequence data deluge on the performance of methods for detecting protein functional residues.

    Science.gov (United States)

    Garrido-Martín, Diego; Pazos, Florencio

    2018-02-27

    The exponential accumulation of new sequences in public databases is expected to improve the performance of all the approaches for predicting protein structural and functional features. Nevertheless, this was never assessed or quantified for some widely used methodologies, such as those aimed at detecting functional sites and functional subfamilies in protein multiple sequence alignments. Using raw protein sequences as only input, these approaches can detect fully conserved positions, as well as those with a family-dependent conservation pattern. Both types of residues are routinely used as predictors of functional sites and, consequently, understanding how the sequence content of the databases affects them is relevant and timely. In this work we evaluate how the growth and change with time in the content of sequence databases affect five sequence-based approaches for detecting functional sites and subfamilies. We do that by recreating historical versions of the multiple sequence alignments that would have been obtained in the past based on the database contents at different time points, covering a period of 20 years. Applying the methods to these historical alignments allows quantifying the temporal variation in their performance. Our results show that the number of families to which these methods can be applied sharply increases with time, while their ability to detect potentially functional residues remains almost constant. These results are informative for the methods' developers and final users, and may have implications in the design of new sequencing initiatives.

  7. Assessment of Protein Side-Chain Conformation Prediction Methods in Different Residue Environments

    Science.gov (United States)

    Peterson, Lenna X.; Kang, Xuejiao; Kihara, Daisuke

    2016-01-01

    Computational prediction of side-chain conformation is an important component of protein structure prediction. Accurate side-chain prediction is crucial for practical applications of protein structure models that need atomic detailed resolution such as protein and ligand design. We evaluated the accuracy of eight side-chain prediction methods in reproducing the side-chain conformations of experimentally solved structures deposited to the Protein Data Bank. Prediction accuracy was evaluated for a total of four different structural environments (buried, surface, interface, and membrane-spanning) in three different protein types (monomeric, multimeric, and membrane). Overall, the highest accuracy was observed for buried residues in monomeric and multimeric proteins. Notably, side-chains at protein interfaces and membrane-spanning regions were better predicted than surface residues even though the methods did not all use multimeric and membrane proteins for training. Thus, we conclude that the current methods are as practically useful for modeling protein docking interfaces and membrane-spanning regions as for modeling monomers. PMID:24619909

  8. Residual stress measurement of EB-welded plates with contour method. Part 2: FEM analysis of contour profiles

    International Nuclear Information System (INIS)

    Romppanen, A.-J.; Immonen, E.

    2013-12-01

    The residual stresses formed as a result of Electronic Beam welding (EB-welding) in copper are investigated by Posiva. In the present study, residual stresses of EB-welded copper plates were studied with contour method. In the method eleven copper plates (X436 - X440 and X453 - X458) were cut in half with wire electric discharge machining (EDM) after which the deformation due to stress relaxation was measured with coordinate measurement system. The measured data was then used as boundary displacement data for the FEM analyses, in which the corresponding residual stresses were calculated. Before giving the corresponding displacement boundary conditions to the FE models, the deformation data was processed and smoothed appropriately. The residual stress levels of the copper plates were found to be around 40 - 55 MPa at maximum. This corresponds to other reported residual stress measurements and current state of knowledge with this material in Posiva. (orig.)

  9. Treatment methods and comparative risks of thorium removal from waste residues

    Energy Technology Data Exchange (ETDEWEB)

    Porter, R.D.; Hamby, D.M.; Martin, J.E.

    1997-07-01

    This study was done to examine the risks of remediation and the effectiveness of removal methods for thorium and its associated radioactive decay products from various soils and wastes associated with DOE`s Formerly Utilized Sites Remedial Action Program (FUSRAP). Removal of {sup 230}Th from uranium process residues would significantly reduce the buildup of {sup 226}Ra (half-life of 1600 years), and since {sup 230}Th concentrations at most of the important sites greatly exceed the {sup 226}Ra concentrations, such removal would reduce the accumulation of additional radiation risks associated with {sup 226}Ra and its products; and, if treatment also removed {sup 226}Ra, these risks could be mitigated even further. Removal of {sup 232}Th from thorium process residues would remove the source material for {sup 228}Ra, and since {sup 228}Ra has a half-life of 5.76 years, its control at FUSRAP sites could be done with land use controls for the 30--50 years required for {sup 228}Ra and the risks associated with its decay products to decay away. It must be recognized, however, that treatment methods invariably require workers to process residues and waste materials usually with bulk handling techniques. These processes expose workers to the radioactivity in the materials, therefore, workers would incur radiological risks in addition to industrial accident risks. An important question is whether the potential reduction of future radiological risks to members of the public justifies the risks that are incurred by remediation workers due to handling materials. This study examines, first, the effectiveness of treatment and then the risks that would be associated with remediation.

  10. Zeranol: a review of the metabolism, toxicology, and analytical methods for detection of tissue residues

    International Nuclear Information System (INIS)

    Baldwin, R.S.; Williams, R.D.; Terry, M.K.

    1983-01-01

    Zeranol, an anabolic agent produced commercially for use in cattle and sheep intended for human consumption, is noncarcinogenic, nonteratogenic, and nonmutagenic. Toxicity testing (acute, subacute, and chronic) in several species by various routes of administration reveals an extremely low toxicity, the oral rat LD 50 exceeding 40 g/kg. Postmortem abnormalities of high-dose animals are attributed to the effects of the compound on the endocrine system. Both zeranol itself and zearalanone, the major Phase I metabolite in the seven species studied, are excreted in the feces and in the urine, either free or as sulfates/glucuronides. A minor urinary metabolite has been identified as taleranol, an epimer of zeranol. Both metabolites exhibit a very low order of toxicity (oral rat LD 50 exceeding 10 g/kg in both cases), and both exhibit less biological activity than the parent compound. The four types of analytical methods which have been employed for the specific detection and quantitation of residues of zeranol in edible tissues are: (1) gas chromatography (detection limit . 20 ppb), (2) high-performance liquid chromatography (detection limit . 5 ppb), (3) thin-layer chromatography (detection limit . 1-3 ppb), and (4) radioimmunoassay methods (detection limit to be published). The following residue levels were determined radiometrically in tissue samples taken 45 days after implantation of cattle with 36 mg tritiated zeranol: less than or equal to 2 ppb in liver, less than or equal to 1 ppb in kidney and fat, and less than or equal to 0.2 ppb in muscle and plasma. A no-effect level (NEL) of 0.225 mg/kg was determined as the highest oral dosage of zeranol which produced no estrogenic effects in female monkeys. Based on the NEL, a tolerance level for tissue residues of zeranol was calculated as 315 ppb

  11. Treatment methods and comparative risks of thorium removal from waste residues

    International Nuclear Information System (INIS)

    Porter, R.D.; Hamby, D.M.; Martin, J.E.

    1997-07-01

    This study was done to examine the risks of remediation and the effectiveness of removal methods for thorium and its associated radioactive decay products from various soils and wastes associated with DOE's Formerly Utilized Sites Remedial Action Program (FUSRAP). Removal of 230 Th from uranium process residues would significantly reduce the buildup of 226 Ra (half-life of 1600 years), and since 230 Th concentrations at most of the important sites greatly exceed the 226 Ra concentrations, such removal would reduce the accumulation of additional radiation risks associated with 226 Ra and its products; and, if treatment also removed 226 Ra, these risks could be mitigated even further. Removal of 232 Th from thorium process residues would remove the source material for 228 Ra, and since 228 Ra has a half-life of 5.76 years, its control at FUSRAP sites could be done with land use controls for the 30--50 years required for 228 Ra and the risks associated with its decay products to decay away. It must be recognized, however, that treatment methods invariably require workers to process residues and waste materials usually with bulk handling techniques. These processes expose workers to the radioactivity in the materials, therefore, workers would incur radiological risks in addition to industrial accident risks. An important question is whether the potential reduction of future radiological risks to members of the public justifies the risks that are incurred by remediation workers due to handling materials. This study examines, first, the effectiveness of treatment and then the risks that would be associated with remediation

  12. Marker-based method to measure movement between the residual limb and a transtibial prosthetic socket.

    Science.gov (United States)

    Childers, Walter Lee; Siebert, Steven

    2016-12-01

    Limb movement between the residuum and socket continues to be an underlying factor in limb health, prosthetic comfort, and gait performance yet techniques to measure this have been underdeveloped. Develop a method to measure motion between the residual limb and a transtibial prosthetic socket. Single subject, repeated measures with mathematical modeling. The gait of a participant with transtibial amputation was recorded using a motion capture system using a marker set that included arrays on the anterior distal tibia and the lateral epicondyle of the femur. The proximal or distal translation, anterior or posterior translation, and angular movements were quantified. A random Monte Carlo simulation based on the precision of the motion capture system and a model of the bone moving under the skin explored the technique's accuracy. Residual limb tissue stiffness was modeled as a linear spring based on data from Papaioannou et al. Residuum movement relative to the socket went through ~30 mm, 18 mm, and 15° range of motion. Root mean squared errors were 5.47 mm, 1.86 mm, and 0.75° when considering the modeled bone-skin movement in the proximal or distal, anterior or posterior, and angular directions, respectively. The measured movement was greater than the root mean squared error, indicating that this method can measure motion between the residuum and socket. The ability to quantify movement between the residual limb and the prosthetic socket will improve prosthetic treatment through the evaluation of different prosthetic suspensions, socket designs, and motor control of the prosthetic interface. © The International Society for Prosthetics and Orthotics 2015.

  13. Method for the Collection, Gravimetric and Chemical Analysis of Nonvolatile Residue (NVR) on Surfaces

    Science.gov (United States)

    Gordon, Keith; Rutherford, Gugu; Aranda, Denisse

    2017-01-01

    Nonvolatile residue (NVR), sometimes referred to as molecular contamination is the term used for the total composition of the inorganic and high boiling point organic components in particulates and molecular films deposited on critical surfaces surrounding space structures, with the particulate and NVR contamination originating primarily from pre-launch operations. The "nonvolatile" suggestion from the terminology NVR implies that the collected residue will not experience much loss under ambient conditions. NVR has been shown to have a dramatic impact on the ability to perform optical measurements from platforms based in space. Such contaminants can be detected early by the controlled application of various detection techniques and contamination analyses. Contamination analyses are the techniques used to determine if materials, components, and subsystems can be expected to meet the performance requirements of a system. Of particular concern is the quantity of NVR contaminants that might be deposited on critical payload surfaces from these sources. Subsequent chemical analysis of the contaminant samples by infrared spectroscopy and gas chromatography mass spectrometry identifies the components, gives semi-quantitative estimates of contaminant thickness, indicates possible sources of the NVR, and provides guidance for effective cleanup procedures. In this report, a method for the collection and determination of the mass of NVR was generated by the authors at NASA Langley Research Center. This report describes the method developed and implemented for collecting NVR contaminants, and procedures for gravimetric and chemical analysis of the residue obtained. The result of this NVR analysis collaboration will help pave the way for Langley's ability to certify flight hardware outgassing requirements in support of flight projects such as Stratospheric Aerosol and Gas Experiment III (SAGE III), Clouds and the Earth's Radiant Energy System (CERES), Materials International

  14. Development of a multi-residue screening method for the determination of pesticides in cereals and dry animal feed using gas chromatography-triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Walorczyk, Stanisław

    2007-09-21

    A multi-residue screening method for simultaneous analysis of 122 gas chromatography amenable pesticides in dry matrices such as cereal grain and certain feedingstuffs was developed. The method entails a simple extraction of re-hydrated sample with acetonitrile followed by a dispersive solid phase extraction (dispersive-SPE) clean-up step prior to the final determination by gas chromatography/triple quadrupole tandem mass spectrometry (GC-MS/MS). Due to complexity of analyzed matrices, two MS/MS transitions were set for each pesticide to eliminate the need for re-analysis of potentially positive samples, and provide unequivocal identification of detected pesticides in accordance with recent guidelines, in a single analytical run. Thus, in the developed GC-MS/MS acquisition method, a total of 216 different multiple reactions monitoring (MRM) transitions were monitored in one set of experimental conditions. To evaluate performance of the method, validation experiments were carried out on wheat grain at three spiking levels (0.01, 0.02 and 0.05 mg kg(-1)). Additional recovery tests at 0.05 mg kg(-1) were carried out on several other matrices. The recoveries ranged between 73 and 129% with associated relative standard deviations between 1 and 29% for the majority of pesticides. Limits of detection were less or equal to 0.01 mg kg(-1) for approximately 68% of pesticides. The applicability of the proposed method to detect and quantify pesticide residues has been demonstrated in the analysis of 136 real samples. Additionally, the method was favorably compared with an acetone extraction method (accepted as a reference method by some of European and U.S. authorities) in the analysis of real samples known to contain pesticide residues.

  15. Evaluating the residual stress in PbTiO3 thin films prepared by a polymeric chemical method

    International Nuclear Information System (INIS)

    Valim, D; Filho, A G Souza; Freire, P T C; Filho, J Mendes; Guarany, C A; Reis, R N; Araujo, E B

    2004-01-01

    We report a study of residual stress in PbTiO 3 (PT) thin films prepared on Si substrates by a polymeric chemical method. The E(1TO) frequency was used to evaluate the residual stress through an empirical equation available for bulk PT. We find that the residual stress in PT films increases as the film thickness decreases and conclude that it originates essentially from the contributions of extrinsic and intrinsic factors. Polarized Raman experiments showed that the PT films prepared by a polymeric chemical method are somewhat a-domain (polar axis c parallel to the substrate) oriented

  16. A method to determine residue levels of persistent organochlorine pesticides in human milk from Indonesian women.

    Science.gov (United States)

    Burke, Emma R; Holden, Alexis J; Shaw, Ian C

    2003-01-01

    A method has been developed for the analysis of organochlorine pesticides in human milk using solvent extraction, Florisil solid phase extraction clean-up and analysis by gas chromatography with an electron capture detector. The recovery of analytes from spiked milk samples was in the range 53 +/- 1% to 109 +/- 7% (n = 9). A small number of samples were obtained from women in a rural and an urban area of Indonesia and analysed using the developed method. The results are reported on a milk fat basis. All samples contained detectable residues of p,p'-DDT (urban mean 0.11 +/- 0.18 mgkg(-1) (n = 5), rural mean 0.07 +/- 0.03 mg kg(-1) (n = 5)) and p,p'-DDE (urban mean 0.05 +/- 0.04 m kg(-1) (n = 5), rural mean 0.76 +/- 1.46 mg kg(-1) (n = 5)). Residues of HCB, betaHCH, alpha-endosulfan and dieldrin were also detected in some samples. There was no significant difference (at the 95% confidence level) in levels of pesticides between urban and rural areas. The levels of organochlorine pesticides in milk from Indonesian women were lower than those reported from Indonesian women exposed to DDT through malaria eradication schemes and were similar to levels reported from UK and Japan.

  17. Pink shrimp (P. brasiliensis and P. paulensis) residue: influence of extraction method on carotenoid concentration.

    Science.gov (United States)

    Mezzomo, Natália; Maestri, Bianca; dos Santos, Renata Lazzaris; Maraschin, Marcelo; Ferreira, Sandra R S

    2011-09-15

    The main residue from the shrimp processing is formed by head and carapace and represents from 40 to 50% (w/w) of the integral shrimp. The recovery of the carotenoid fraction from this residue stands for an alternative to increase its aggregated value. Therefore, the objective of this study was to use the pink shrimp waste as raw material to obtain carotenoid enriched extracts, evaluating different pre-treatments and extraction methods. The shrimp waste was supplied by a local public market (Florianópolis, SC, Brazil). The investigation of the different pre-treatments applied to the raw material shows that cooking associated with milling and drying produced the extract richest in carotenoid fraction. The extraction methods considered in this work were Soxhlet, maceration and ultrasound by means of different organic solvents and also a vegetable oil as solvent. The extracts were evaluated in terms of yield, carotenoid profile, total carotenoid content (TCC), UV-Visible scanning spectrophotometry and mid-Fourier transform infrared spectroscopy (FTIR). The results indicate that shrimp waste can provide carotenoid enriched extracts, particularly astaxanthin, in concentrations up to 252 μg(astaxanthin)g(extract)(-1). The most adequate solvents were acetone and hexane: isopropanol (50:50, v/v) used in the maceration procedure. The UV-Vis results revealed the presence of carotenoids and flavonoids in the extracts while the FTIR spectroscopy indicated the existence of fatty acids, proteins, and phenolics. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Determination the Amount of Illegal Furazolidone Residues in Broilers in Ahvaz Abattoir by HPLC Method

    Directory of Open Access Journals (Sweden)

    A Fazlara

    2014-06-01

    Full Text Available Background & aim: due to the risks to human health, particularly in terms of carcinogenicity, the application of Furazolidone in animals which their products are consumed by human population is strongly prohibited. The purpose of this study was to determine the amount of unauthorized furazolidone in broiler chickens slaughtered in Ahvaz by using HPLC. Methods: In the present cross-sectional study which was conducted within six months, 100 broiler carcasses were randomly collected from Ahvaz slaughterhouses. Then by using ice, the carcasses were transported to the laboratory in less than 24 hours inorder to illicit the amount of furazolidone drug by the HPLC method. After extraction and degrading processes, using Ethyl-acetate and related protocols for isolation of Furazolidone from muscles, and also calibrating HPLC system to obtain standard curves, the amount of 20 microliters of each sample was injected to the HPLC device and the amounts of Furazolidone were determined in the mixture of pectoral and femoral muscles. Finally the obtained results were statistically analysed by using one sample t-test in the SPSS software. Results: The mean Furazolidone concentration in the mixture of femoral and thorasic muscles was 28.15±2.37 mg/kg. Thirty-nine percent of the samples were positive for containing illegal Furazolidone residue. Conclusion: According to the results of the current study, more attention is seriously recommended by authorized responsibilities to prevent the antibiotic residues such as furazolidone in poultry meat.

  19. Comparison of Methods for Bifenthrin Residues Determination in Fermented Wheat Samples

    Directory of Open Access Journals (Sweden)

    Tijana Đorđević

    2012-01-01

    Full Text Available Efficiency of three different sample preparation methods for GC/MS determinationof bifenthrin residues in wheat (Triticum spelta samples fermented by Lactobacillusplantarum was tested. The first method was based on a methanol:acetone=1:1 extractionfolowed by a purification on columns containing mixture of aluminium oxide and activatedcharcoal slurry-packed and eluted with dichlormethane, the second was based onmethanol:acetone=1:1 extraction folowed by the purification on florisil column and elutionby ethil acetate:acetone=4:1, while the third tested method was based on a combinationof the first two mentioned methods, thus methanol:acetone=1:1 extraction and clean-upthrought columns filled with a mixture of aluminum oxide and activated charcoal slurrypackedand eluted with ethil acetate:acetone=4:1. The second method was the most effectivefor obtaining satisfactory recoveries for bifenthrin in a range of 79-83% for four fortificationlevels, with good reproducibility i.e. RSD% in a range of 2.2-7.4%. The chosen methodwas further optimized by assessing the optimum volume of elution solvent used duringthe clean-up procedures. The highest recovery of 82.1% was obtained after elution with25 ml of solvent. Overall, two-step extraction with 25 ml of methanol:acetone=1:1 solventmix for 30 min, followed by clean-up procedure through a glass column with florisil coupledwith elution with 25 ml of ethyl acetate: acetone=4:1, allows simple, efficient and reliableGC/MS detection of bifenthrin residues from wheat grain fermented by L. plantarum.

  20. Depth-resolved residual stress evaluation from X-ray diffraction measurement data using the approximate inverse method

    CERN Document Server

    Schuster, T; Louis, A K

    2003-01-01

    The paper deals with the depth determination of residual stress states from diffraction data. First an historical overview of the known approaches is given. Then we apply the approximate inverse method to this problem. This method is known to be very efficient and stable with respect to noise-contaminated data. It is even possible to prove convergence and it allows an error estimate of the calculated depth resolved residual stress profile. (orig.)

  1. The difference of acrylic resin residual monomer levels with various polymerization method

    Directory of Open Access Journals (Sweden)

    Sherman Salim

    2011-12-01

    Full Text Available Background: After polymerization process, heat cured acrylic resin denture base actually still contains residual monomers that can become potential irritants later in oral cavity. Polymerization process is essential to obtain acrylic resin which can meet the requirements of the biocompatible and good physical properties. To meet the requirements, there are several methods of polymerization process used. Purpose: The purpose of this study was to determine the differences of the residual monomer levels of acrylic resin processed by various polymerization methods. Methods: Acrylic resin powder and liquid were mixed based on the rules of factory, and sample was made with size of 30 mm × 50 mm × 3 mm and then polymerized by using microwave at 70° C for 24 hours based on the methods of Japan Industrial Standard (JIS. Each group of samples was cut with weight of ± 0.2 g, dissolved in 5 ml of methyl ethyl ketone in test tubes, and then stored at ± 5° C for four days. Residual monomer level was conducted by using gas chromatograph mass spectrometer. Data obtained were then analyzed by using One-Way ANOVA test with p < 0.05. Results: After the level of polymerizing residual monomer with JIS method was compared to that at 70° C for 24 hours using microwave, it is known that there were significant differences (p < 0.05. Conclusion: The highest level of residual monomer of acrylic resin was that polymerized at 70° C for 24 hours.Latar belakang: Basis gigi tiruan yang berbahan dasar resin akrilik jenis heat cured setelah proses polimerisasi selesai masih mengandung monomer sisa yang berpotensi sebagai bahan iritan dalam rongga mulut. Proses polimerisasi sangat penting untuk mendapatkan resin akrilik yang memenuhi persyaratan biokompatibilitas dan fisik yang baik. Untuk persyaratan tersebut digunakan berbagai macam proses polimerisasi. Tujuan: Penelitian ini bertujuan untuk menentukan kadar monomer sisa resin akrilik yang diproses dengan metode

  2. Analysis of the monitoring status of residual nitrite in meat products in China from 2000 to 2011.

    Science.gov (United States)

    Zhang, Hongchao; Sun, Changbao; Han, Wanjun; Zhang, Jiaxiu; Hou, Juncai

    2018-02-01

    The aim of this article was to analyze the monitoring status of nitrite in meat products consumed from 2000 to 2011 in 24 provinces, autonomous regions or direct-controlled municipalities in China. Statistical analyses were performed on the monitoring status including number, proportion, and distribution of 13,316 samples, of which 11,320 (85%) contained up to 2808.2mg/kg nitrite and 1996 (15%) contained no nitrite. A total of 10,299 samples (77%) qualified for GB/T 5009.33-2003, 2003; however, 3017 samples (23%) contained nitrite at levels higher than the national standard. The districts with high percentage of samples with no nitrite were Shanghai (49%), Beijing (47%), and Liaoning (30%). While the districts with high percentage of meat products containing nitrite at levels exceeding the national standard were Jiangxi (49%), Jiangsu (33%), Shandong (29%) and Sichuan (29%). Therefore, the status of residue nitrite in meat products is of concern. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Escherichia Coli-Lux Biosensor Used to Monitor the Cytotoxicity and Genotoxicity of Pharmacological Residues in Environment

    Directory of Open Access Journals (Sweden)

    Eliza Hawrylik

    2018-05-01

    Full Text Available The aim of the study was to evaluate the usefulness of Escherichia coli K-12 RFM 443 recA::lux for cytotoxicity and genotoxicity monitoring of metoprolol in the environment. Metoprolol is one of the most popular cardiac drug which belongs to the group of β–blockers. The drug was applied at concentrations ranging from 0.01 µg/cm3 to 100 µg/cm3. The conducted studies are preliminary studies aimed at validation of the recA::lux gene construct in the direction of determining its sensitivity to metoprolol. The drug concentrations were selected experimentally to obtain a positive luminescence response. Obtained data indicated the influence of metoprolol on lux gene expression and recA promoter activity based on the use of laboratory samples using PBS buffer. Results indicate a potential possibility of using a bacterial biosensor Escherichia coli K - 12 RFM 443 with recA::lux gene fusion in cytotoxicity and genotoxicity monitoring of the cardiac drugs residue in the environment.

  4. An improved method for collecting and monitoring pine oleoresin

    Science.gov (United States)

    Dick Karsky; Brian Strom; Harold Thistle

    2004-01-01

    A new method for collecting and monitoring pine oleoresin has been developed through a cooperative project involving the Missoula Technology Development Center (MTDC), Southern Research Station (Brian Strom, research entomologist), and the Forest Health Technology Enterprise Team. The new sampling unit (figure 1) is cast from rugged plastic. It provides a closed system...

  5. Forest Service National Visitor Use Monitoring Process: Research Method Documentation

    Science.gov (United States)

    Donald B.K. English; Susan M. Kocis; Stanley J. Zarnoch; J. Ross Arnold

    2002-01-01

    In response to the need for improved information on recreational use of National Forest System lands, the authors have developed a nationwide, systematic monitoring process. This report documents the methods they used in estimating recreational use on an annual basis. The basic unit of measure is exiting volume of visitors from a recreation site on a given day. Sites...

  6. Field test of a new Australian method of rangeland monitoring

    Science.gov (United States)

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...

  7. Fluorescent method for monitoring cheese starter permeabilization and lysis

    NARCIS (Netherlands)

    Bunthof, C.J.; Schalkwijk, van S.; Meijer, W.; Abee, T.; Hugenholtz, J.

    2001-01-01

    A fluorescence method to monitor lysis of cheese starter bacteria using dual staining with the LIVE/DEAD BacLight bacterial viability kit is described. This kit combines membrane-permeant green fluorescent nucleic acid dye SYTO 9 and membrane-impermeant red fluorescent nucleic acid dye propidium

  8. [Monitoring of the residue of fosthiazate in water samples using solid-phase extraction coupled with gas chromatography/mass spectrometry].

    Science.gov (United States)

    Zhu, Jing; Zhou, Xin; Fu, Chunmei; Liu, Sankang; Li, Zhangwan

    2004-11-01

    Solid-phase extraction (SPE) coupled with gas chromatography/mass spectrometry (GC/MS) was used to determine the fosthiazate residue in water samples. The water samples were first filtered through cellulose filters (0.45 microm pore size). A 100 mL volume of filtered water, in which 1 mL of methanol has been added, was then passed through a pre-conditioned 3 cm C18 cartridge at a flow-rate of 1.5 mL/min. Elution was performed by 1 mL of methanol. The eluant was finally dried under reduced pressure for solvent evaporation. The volume was quantitatively adjusted to 0.5 mL with methanol. The analysis was carried out on GC/MS. The mass spectrometer was operated in selected ion monitoring (SIM) mode. According to mass spectrum of fosthiazate, three selected ions at m/z of 126, 195, 283, respectively, were monitored for identification and quantification. High sensitivity and selectivity were achieved by using this method. The limit of detection for fosthiazate in water samples was determined to be 56.4 ng/L. The linearity was demonstrated over a wide range of concentrations covering from 0.282 to 141 microg/L. The recoveries were more than 85.5% and the relative standard deviations for the overall procedure were less than 4.42%. The fosthiazate residue was detected in the water samples from a pool near cropland where fosthiazate was used. The results demonstrate the suitability of the SPE-GC/MS approach for the analysis of fosthiazate in water.

  9. Methods for conditioning wastes from spent fuel cans and dissolver residues

    International Nuclear Information System (INIS)

    De Regge, P.; Loida, A.; Schmidt-Hansberg, T.; Sombret, C.

    1985-04-01

    Several methods for conditioning spent fuel decladding hulls or dissolver residues have been considered in various countries of the European Community. Five of these methods use embedding technique with or without prior compaction: they are based on incorporation in metallic alloys, glass, ceramics, cements and metals or graphite compounds. A sixth one consists in melting the decladding materials. The corresponding research programs have been pursued to varying states of progress with regard to demonstrating their feasibility on an industrial scale and the use of genuine wastes in bench scale experiments. The properties of the conditioned wastes have been investigated. Special attention has been paid to the corrosion resistance to various aqueous media as tap water, brine or clayey water. Although no categorical conclusion can be drawn from the initial results, the available finding provide a basis for assessing the different processes [fr

  10. Method for identification of rigid domains and hinge residues in proteins based on exhaustive enumeration.

    Science.gov (United States)

    Sim, Jaehyun; Sim, Jun; Park, Eunsung; Lee, Julian

    2015-06-01

    Many proteins undergo large-scale motions where relatively rigid domains move against each other. The identification of rigid domains, as well as the hinge residues important for their relative movements, is important for various applications including flexible docking simulations. In this work, we develop a method for protein rigid domain identification based on an exhaustive enumeration of maximal rigid domains, the rigid domains not fully contained within other domains. The computation is performed by mapping the problem to that of finding maximal cliques in a graph. A minimal set of rigid domains are then selected, which cover most of the protein with minimal overlap. In contrast to the results of existing methods that partition a protein into non-overlapping domains using approximate algorithms, the rigid domains obtained from exact enumeration naturally contain overlapping regions, which correspond to the hinges of the inter-domain bending motion. The performance of the algorithm is demonstrated on several proteins. © 2015 Wiley Periodicals, Inc.

  11. Unsupervised process monitoring and fault diagnosis with machine learning methods

    CERN Document Server

    Aldrich, Chris

    2013-01-01

    This unique text/reference describes in detail the latest advances in unsupervised process monitoring and fault diagnosis with machine learning methods. Abundant case studies throughout the text demonstrate the efficacy of each method in real-world settings. The broad coverage examines such cutting-edge topics as the use of information theory to enhance unsupervised learning in tree-based methods, the extension of kernel methods to multiple kernel learning for feature extraction from data, and the incremental training of multilayer perceptrons to construct deep architectures for enhanced data

  12. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  13. Simultaneous Determination of TetracyclinesResidues in Bovine Milk Samples by Solid Phase Extraction and HPLC-FL Method

    Directory of Open Access Journals (Sweden)

    Mehra Mesgari Abbasi

    2011-06-01

    Full Text Available Introduction:Tetracyclines (TCs are widely used in animal husbandry and their residues in milk may resultinharmful effects on human. The aim of this study was to investigate the presence of TCs residues in various bovine milk samples from local markets of Ardabil, Iran. Methods:One hundred and fourteen pasteurized, sterilized and raw milk samples were collected from markets of Ardabil. Tetracycline, Oxytetracycline and Chlortetracycline (TCs residues extraction carried out by Solid Phase Extraction method. Determination of TCs residues were performed by high performance liquid chromatography (HPLC method using Fluorescence detector.Results: The mean of total TCs residues in all samples (114 samples was 97.6 ±16.9ng/g and that of pasteurized, sterilized and raw milk samples were 87.1 ± 17.7, 112.0 ± 57.3 and 154.0 ± 66.3ng/g respectively. Twenty five point four percent of the all samples, and24.4%, 30% and 28.6% of the pasteurized, sterilized and raw milk samples, respectively had higher TCs residues than the recommended maximum levels (100ng/g. Conclusion:This study indicates the presence of tetracycline residues more than allowed amount. Regulatory authorities should ensure proper withdrawal period before milking the animals and definite supervisions are necessary on application of these drugs.

  14. Stem cell monitoring with a direct or indirect labeling method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Hwan; Lee, Yong Jin [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of)

    2016-12-15

    The molecular imaging techniques allow monitoring of the transplanted cells in the same individuals over time, from early localization to the survival, migration, and differentiation. Generally, there are two methods of stem cell labeling: direct and indirect labeling methods. The direct labeling method introduces a labeling agent into the cell, which is stably incorporated or attached to the cells prior to transplantation. Direct labeling of cells with radionuclides is a simple method with relatively fewer adverse events related to genetic responses. However, it can only allow short-term distribution of transplanted cells because of the decreasing imaging signal with radiodecay, according to the physical half-lives, or the signal becomes more diffuse with cell division and dispersion. The indirect labeling method is based on the expression of a reporter gene transduced into the cell before transplantation, which is then visualized upon the injection of an appropriate probe or substrate. In this review, various imaging strategies to monitor the survival and behavior change of transplanted stem cells are covered. Taking these new approaches together, the direct and indirect labeling methods may provide new insights on the roles of in vivo stem cell monitoring, from bench to bedside.

  15. System and Method for Monitoring Piezoelectric Material Performance

    Science.gov (United States)

    Moses, Robert W. (Inventor); Fox, Christopher L. (Inventor); Fox, Melanie L. (Inventor); Chattin, Richard L. (Inventor); Shams, Qamar A. (Inventor); Fox, Robert L. (Inventor)

    2007-01-01

    A system and method are provided for monitoring performance capacity of a piezoelectric material that may form part of an actuator or sensor device. A switch is used to selectively electrically couple an inductor to the piezoelectric material to form an inductor-capacitor circuit. Resonance is induced in the inductor-capacitor circuit when the switch is operated to create the circuit. The resonance of the inductor-capacitor circuit is monitored with the frequency of the resonance being indicative of performance capacity of the device's piezoelectric material.

  16. Wide-Scope Screening Method for Multiclass Veterinary Drug Residues in Fish, Shrimp, and Eel Using Liquid Chromatography-Quadrupole High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R

    2017-08-30

    A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.

  17. Recovery of signal loss adopting the residual bootstrap method in fetal heart rate dynamics.

    Science.gov (United States)

    Lee, Sun-Kyung; Park, Young-Sun; Cha, Kyung-Joon

    2018-03-19

    Fetal heart rate (FHR) data obtained from a non-stress test (NST) can be presented in a type of time series, which is accompanied by signal loss due to physical and biological causes. To recover or estimate FHR data, which is subjected to a high rate of signal loss, time series models [second-order autoregressive (AR(2)), first-order autoregressive conditional heteroscedasticity (ARCH(1)) and empirical mode decomposition and vector autoregressive (EMD-VAR)] and the residual bootstrap method were applied. The ARCH(1) model with the residual bootstrap technique was the most accurate [root mean square error (RMSE), 2.065] as it reflects the nonlinearity of the FHR data [mean absolute error (MAE) for approximate entropy (ApEn), 0.081]. As a result, the goal of predicting fetal health and identifying a high-risk pregnancy could be achieved. These trials may be effectively used to save the time and cost of repeating the NST when the fetal diagnosis is impossible owing to a large amount of signal loss.

  18. Comparison of Measured Residual Stress in an Extra Thick Multi-pass Weld Using Neutron Diffraction Method and Inherent Strain Method

    International Nuclear Information System (INIS)

    Park, JeongUng; An, GyuBaek; Woo, Wan Chuck

    2015-01-01

    With the increase of large-scale containership, a large amount of high-strength steels with extra thick plates is being extensively used. The welding stress existing in the extra thick welded plates has a significant effect on the integrity of the component in terms of brittle fracture and fatigue behavior. It has been reported that welding residual stress distribution in an extra thick plate can affect the propagation path of the crack. Therefore, it is important to measure the distribution of welding residual stresses for the reliable design of the welded structures. So far various researches have been carried out for the determination of residual stresses on the surface of steels. In this paper, the total residual stresses in the 70 mm thick multipass FACW butt joint were measured by integrating initial stress into ISM. Concretely, two methods named as initial stress integrated ISM and initial inherent strain integrated ISM were employed to determine the total residual stresses. Furthermore, the distributions of residual stresses were compared with the results of the Neutron Diffraction Method(NDM). In order to measure the three dimensional residual stresses in the welded joint with initial stresses existing before welding, initial stress integrated ISM and initial inherent strain integrated ISM were developed. The residual stresses in 70 mm-thick butt joint by flux cored arc welding were carried out with a good accuracy using the two developed methods. The residual stresses in welded joint using both initial stress integrated ISM and initial inherent strain integrated ISM agreed well with the results measured by Neutron Diffraction Method. This suggests that the integrated ISM is a reliable method for residual stress measurement if initial stress existed

  19. Development and validation of an alternative to conventional pretreatment methods for residue analysis of butachlor in water, soil, and rice.

    Science.gov (United States)

    Xue, Jiaying; Jiang, Wenqing; Liu, Fengmao; Zhao, Huiyu; Wang, Suli; Peng, Wei

    2014-01-01

    A rapid and effective alternative analytical method for residues of butachlor in water, soil, and rice was established. The operating variables affecting performance of this method, including different extraction conditions and cleanup adsorbents, were evaluated. The determination of butachlor residues in soil, straw, rice hull, and husked rice was performed using GC/MS after extraction with n-hexane and cleanup with graphite carbon black. The average recoveries ranged from 81.5 to 102.7%, with RSDs of 0.6-7.7% for all of the matrixes investigated. The limits of quantitation were 0.05 mg/kg in water and rice plant, and 0.01 mg/kg in soil, straw, rice hull, and husked rice. A comparison among this proposed method, the conventional liquid-liquid extraction, the Quick, Easy, Cheap, Effective, Rugged, and Safe method, and Soxhlet extraction indicated that this method was more suitable for analyzing butachlor in rice samples. The further validation of the proposed method was carried out by Soxhlet extraction for the determination of butachlor residues in the husked rice samples, and the residue results showed there was no obvious difference obtained from these two methods. Samples from a rice field were found to contain butachlor residues below the maximum residue limits set by China (0.5 mg/kg) and Japan (0.1 mg/kg). The proposed method has a strong potential for application in routine screening and processing of large numbers of samples. This study developed a more effective alternative to the conventional analytical methods for analyzing butachlor residues in various matrixes.

  20. Novel method for fog monitoring using cellular networks infrastructures

    Science.gov (United States)

    David, N.; Alpert, P.; Messer, H.

    2012-08-01

    A major detrimental effect of fog is visibility limitation which can result in serious transportation accidents, traffic delays and therefore economic damage. Existing monitoring techniques including satellites, transmissometers and human observers - suffer from low spatial resolution, high cost or lack of precision when measuring near ground level. Here we show a novel technique for fog monitoring using wireless communication systems. Communication networks widely deploy commercial microwave links across the terrain at ground level. Operating at frequencies of tens of GHz they are affected by fog and are, effectively, an existing, spatially world-wide distributed sensor network that can provide crucial information about fog concentration and visibility. Fog monitoring potential is demonstrated for a heavy fog event that took place in Israel. The correlation between transmissomters and human eye observations to the visibility estimates from the nearby microwave links was found to be 0.53 and 0.61, respectively. These values indicate the high potential of the proposed method.

  1. Application of GNSS Methods for Monitoring Offshore Platform Deformation

    Science.gov (United States)

    Myint, Khin Cho; Nasir Matori, Abd; Gohari, Adel

    2018-03-01

    Global Navigation Satellite System (GNSS) has become a powerful tool for high-precision deformation monitoring application. Monitoring of deformation and subsidence of offshore platform due to factors such as shallow gas phenomena. GNSS is the technical interoperability and compatibility between various satellite navigation systems such as modernized GPS, Galileo, reconstructed GLONASS to be used by civilian users. It has been known that excessive deformation affects platform structurally, causing loss of production and affects the efficiency of the machinery on board the platform. GNSS have been proven to be one of the most precise positioning methods where by users can get accuracy to the nearest centimeter of a given position from carrier phase measurement processing of GPS signals. This research is aimed at using GNSS technique, which is one of the most standard methods to monitor the deformation of offshore platforms. Therefore, station modeling, which accounts for the spatial correlated errors, and hence speeds up the ambiguity resolution process is employed. It was found that GNSS combines the high accuracy of the results monitoring the offshore platforms deformation with the possibility of survey.

  2. Methods to monitor and evaluate household waste prevention.

    Science.gov (United States)

    Sharp, Veronica; Giorgi, Sara; Wilson, David C

    2010-03-01

    This paper presents one strand of the findings from a comprehensive synthesis review of the policy-relevant evidence on household waste prevention. The focus herein is on how to measure waste prevention: it is always difficult to measure what is not there. Yet reliable and robust monitoring and evaluation of household waste prevention interventions is essential, to enable policy makers, local authorities and practitioners to: (a) collect robust and high quality data; (b) ensure robust decisions are made about where to prioritize resources; and (c) ensure that waste prevention initiatives are being effective and delivering behaviour change. The evidence reveals a range of methods for monitoring and evaluation, including self-weighing; pre- and post-intervention surveys, focusing on attitudes and behaviours and/or on participation rates; tracking waste arisings via collection data and/or compositional analysis; and estimation/modelling. There appears to be an emerging consensus that no single approach is sufficient on its own, rather a 'hybrid' method using a suite of monitoring approaches - usually including surveys, waste tonnage data and monitoring of campaigns - is recommended. The evidence concurs that there is no benefit in trying to further collate evidence from past waste prevention projects, other than to establish, in a few selected cases, if waste prevention behaviour has been sustained beyond cessation of the active intervention campaign. A more promising way forward is to ensure that new intervention campaigns are properly evaluated and that the evidence is captured and collated into a common resource.

  3. Experimental design to monitor the influence of crop residue management on the dynamics of soil water content

    Science.gov (United States)

    Chélin, Marie; Hiel, Marie-Pierre; Parvin, Nargish; Bodson, Bernard; Degré, Aurore; Nguyen, Frédéric; Garré, Sarah

    2015-04-01

    Choices related to crop residue management affecting soil structure determine spatio-temporal dynamics of water content and eventually crop yields. In this contribution, we will discuss the experimental design we adopted to study the influence of agricultural management strategies (tillage and residue management) on the soil water dynamics under maize in a Cutanic Siltic Luvisol in Gembloux, Belgium. Three different treatments will be studied: a conventional ploughing realized either in December 2014 or just before sowing in April 2015, and a strip tillage in April 2015. A bare soil under conventional ploughing will also be monitored in order to better understand the influence of the plant over the growing season. In order to limit soil disturbance, we opted for the use of electrical resistivity tomography (ERT) and we use the bulk electrical conductivity as a proxy for soil moisture content. ERT will be collected every week on a surface of two square meters corresponding to three rows of seven maize plants through surface stainless steel electrodes. Five additional sticks with stainless steel electrodes will be vertically inserted into the soil up to 1.50 m to get more detailed information near to the central maize row. In each of the monitoring plots, two time-domain reflectometry (TDR) probes will be installed for data validation. In order to calibrate the relationship between electrical resistivity and soil water content under highly variable field conditions (changes in soil structure, variable weather conditions, plant growth, fertilization), a trench will be dug, in which a set of four electrodes, one TDR probe and one temperature sensor will be placed at four different depths. In addition, two suction cups will be installed in each of the plots to quantify changes in ion composition and electrical conductivity of the soil solution at two different depths. Within the framework of the multidisciplinary research platform AgricultureIsLife, regular assessment

  4. Non-destructive residual pressure self-measurement method for the sensing chip of optical Fabry-Perot pressure sensor.

    Science.gov (United States)

    Wang, Xue; Wang, Shuang; Jiang, Junfeng; Liu, Kun; Zhang, Xuezhi; Xiao, Mengnan; Xiao, Hai; Liu, Tiegen

    2017-12-11

    We introduce a simple residual pressure self-measurement method for the Fabry-Perot (F-P) cavity of optical MEMS pressure sensor. No extra installation is required and the structure of the sensor is unchanged. In the method, the relationship between residual pressure and external pressure under the same diaphragm deflection condition at different temperatures is analyzed by using the deflection formula of the circular plate with clamped edges and the ideal gas law. Based on this, the residual pressure under the flat condition can be obtained by pressure scanning process and calculation process. We carried out the experiment to compare the residual pressures of two batches MEMS sensors fabricated by two kinds of bonding process. The measurement result indicates that our approach is reliable enough for the measurement.

  5. Residual stress evaluation of austenitic stainless steel with a finished surface by polychromatic X-ray method

    Energy Technology Data Exchange (ETDEWEB)

    Shibano, Jun-ichi; Ukai, Takayoshi; Tadano, Shigeru [Hokkaido Univ., Sapporo (Japan). Faculty of Engineering; Todoh, Masahiro

    1995-11-01

    The residual stress in a subsurface layer of austenitic stainless steel with a finished surface was evaluated by the polychromatic X-ray method. A surface of austenitic stainless steel SUS316 plate was ground and lapped as the specimen. In this method, the relation between strain and depth was approximated with a linear function or an exponential function, and it was assumed that the plane stress state existed in each subsurface layer in the depth direction of the specimen. As a result, the residual strain which was estimated under the assumption of the exponential function showed more reasonable distribution than that of the linear function. In addition, the residual stress which was calculated from the strain distribution was maximum tension at the surface of the specimen, and maximum compression at a position 3 {mu}m below the surface. Therefore, the steep gradient of residual stress could be confirmed in a subsurface layer of the SUS316 with a finished surface. (author).

  6. Triaxial Measurement Method for Analysis of Residual Stress after High Feed Milling by X-Ray Diffraction

    Science.gov (United States)

    Čuma, Matúš; Török, Jozef; Telišková, Monika

    2016-12-01

    Surface integrity is a broad term which includes various quality factors affecting the functional properties of parts. Residual stress is one of these factors. Machining generates residual stresses in the surface and subsurface layers of the structural elements. X-ray diffractometry is a non-destructive method applicable for the measurement of residual stresses in surface and subsurface layers of components. The article is focused on the non-destructive progressive method of triaxial measurement of residual stress after machining the surface of sample by high feed milling technology. Significance of triaxial measuring is the capability of measuring in different angles so it is possible to acquire stress tensor containing normal and shear stress components acting in the spot of measuring, using a Cartesian coordinate system.

  7. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  8. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Comparison and evaluation of two methods for the pesticide residue analysis of organophosphates in yerba mate

    Directory of Open Access Journals (Sweden)

    Lucía Pareja

    Full Text Available Abstract Microwave Assisted Extraction and a modified CEN-QuEChERS methodology were evaluated as extraction and clean up procedures for the simultaneous analysis of 42 organophosphate pesticides in yerba mate (Ilex paraguaiensis. The obtained extracts were analyzed by gas chromatography using a flame photometric detector. Linearity, recovery percentages, relative standard deviations, detection and quantification limits and matrix effects were determined according to DG-SANCO guidelines for both methods. At 0.2 and 0.5 mg/kg the evaluated methods showed percentages recoveries between 70 and 120% for most of the analytes. Using Microwave Assisted Extraction methodology, 33 pesticide residues could be properly analyzed whereas only 27 could be determined with the proposed modified QuEChERS. All relative standard deviation were below 18% except for omethoate and disulfoton sulfone when evaluated by the modified QuEChERS. The limits of detection in both methodologies were 0.2 mg/kg for most of the analyzed compounds. The average detection limit for QuEChERS was 0.04 mg/kg. For 19 of the analytes determined through Microwave Assisted Extraction the lowest validated level were 0.004 mg/kg. Signal suppression/enhancement was observed for most of the pesticides, thus matrix-matched calibration curves were used for quantification. The Microwave Assisted Extraction and QuEChERS procedures studied could detect the organophosphate pesticides above the MRL fixed for "mate" by the European Union. They have been successfully applied for the determination of organophosphate pesticide residues in commercial samples and the positives were confirmed through GC–(ITD-MS.

  10. Development and validation of a high-performance liquid chromatography method for determination of ractopamine residue in pork samples by solid phase extraction and pre-column derivatization.

    Science.gov (United States)

    Ding, Guanglong; Li, Deguang; Qin, Jiao; Zhu, Juanli; Wang, Baitao; Geng, Qianqian; Guo, Mingcheng; Punyapitak, Darunee; Cao, Yongsong

    2015-08-01

    Ractopamine (RAC) has been approved as a feed additive for swine, cattle or turkey, and is likely to have residue in edible animal products and may pose a potential risk for consumer health. Therefore, it is essential to establish a method to detect the residue of RAC in animal products. This work presents a rapid and sensitive HPLC method for the determination of RAC in pork samples with pre-column derivatization. The RAC derivative was separated on a kromasil C18 column and detected at 284nm with a UV detector. The detection capability (CCβ) was 0.078μgg(-1) and the linearity was established over the concentration range of 0.15-100.0μgg(-1). The overall mean recovery in spike range of 0.2μgg(-1) to 100μgg(-1) was 89.9% with the overall mean relative standard deviation of 4.1%. This method can be used for the quantification of RAC in pork samples and help to establish adequate monitoring of the residue of RAC. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Multi-residue method for the determination of antibiotics and some of their metabolites in seafood.

    Science.gov (United States)

    Serra-Compte, Albert; Álvarez-Muñoz, Diana; Rodríguez-Mozaz, Sara; Barceló, Damià

    2017-06-01

    The presence of antibiotics in seafood for human consumption may pose a risk for consumers. A methodology for the analysis of antibiotics in seafood based on QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction, followed by detection and quantification using liquid chromatography coupled to mass spectrometry was developed. The analytical method was evaluated for the determination of 23 antibiotics (including parent compounds and some metabolites) in fish, mussels and clams. Recoveries ranged between 30% and 70% for most of the compounds and method detection and quantification limits (MDLs and MQLs) were between 0.01 and 0.31 ng/g dry weigh (dw) and 0.02-1.03 ng/g (dw) respectively. Real seafood samples were analysed using this method. Nine antibiotics were found at levels above MDLs; however none of them exceed the maximum residue limits (MRL) established by the authorities. Tetracycline was the most ubiquitous compound, presenting also the highest concentration: 5.63 ng/g (dw) in fish from Netherlands. In addition, an alternative technique based on microbial growth inhibition was explored as semiquantitative detection method of antibiotics in seafood. This methodology could be applied as a fast screening technique for the detection of macrolides and β-lactams in seafood but further research is needed for other antibiotics families. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Simple and sensitive monitoring of sulfonamide veterinary residues in milk by stir bar sorptive extraction based on monolithic material and high performance liquid chromatography analysis.

    Science.gov (United States)

    Huang, Xiaojia; Qiu, Ningning; Yuan, Dongxing

    2009-11-13

    A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues (SAs) in milk was developed by stir bar sorptive extraction (SBSE) coupling to high performance liquid chromatography with diode array detection. The analytes were concentrated by SBSE based on poly (vinylimidazole-divinylbenzene) monolithic material as coating. The extraction procedure was very simple, milk was diluted with water then directly sorptive extraction without elimination of fats and protein in samples was required. To achieve optimum extraction performance for SAs, several parameters, including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. Under the optimized experimental conditions, low detection limits (S/N=3) quantification limits (S/N=10) of the proposed method for the target compounds were achieved within the range of 1.30-7.90 ng/mL and 4.29-26.3 ng/mL from spiked milk, respectively. Good linearities were obtained for SAs with the correlation coefficients (R(2)) above 0.996. Finally, the proposed method was successfully applied to the determination of SAs compounds in different milk samples and satisfied recoveries of spiked target compounds in real samples were obtained.

  13. Monitoring of wastes containing plutonium. Necessity and method

    International Nuclear Information System (INIS)

    Sousselier, Y.; Pottier, P.

    1979-01-01

    Importance of problems set by wastes containing plutonium is rapidly growing. Plutonium is not a waste, recycling limits heavily the quantity of plutonium to be stored with wastes. Optimized waste management must take definitive storage and economical limits of plutonium recovery into account. Waste monitoring is a must for safety, economy and waste management. Methods used require reliability, simplicity, sensibility and accuracy particularly for threshold detection [fr

  14. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    Science.gov (United States)

    Duan, Yixiang [Los Alamos, NM; Cao, Wenqing [Los Alamos, NM

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  15. Acoustical Method of Whole-Body Hydration Status Monitoring1

    OpenAIRE

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-01-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscl...

  16. Validation of a multi-residue method for the determination of residuals pesticides in cabbage (Brassica Oleracea var. Capitata) for gases chromatography

    International Nuclear Information System (INIS)

    Moreno, Milton Leonardo; Guerrero Dallos, Jairo Arturo

    2002-01-01

    This study describes the validation of a multi-residue method for the determination of most used organo chlorine, organophosphorus and organonitrogen pesticides in cabbage in the Cundinamarca Department (Colombia). The extraction process includes blending of small sample quantity with ethyl acetate in presence of Na 2 SO 4 and NaHCO 3 , filtration and concentration. The clean up steps include GPC and mini-column chromatography using silica gel. Final determination was carried out by gas chromatography with: pulsed splitless injection, HP-5 capillary column, and a parallel detection system with micro electron capture detection (μ - ECD) and Nitrogen-Phosphorus Detection (NPD). The methodology is specific, selective, accurate and robust. Recovery values of majority of pesticides were in the range 70-120% at spiking levels ranging 0.05-10.73 mg/kg. Limits of detection were less than 0.10 mg/kg for most of the studied compounds. The distribution of the analyses in the laboratory sample was evaluated and it was found its homogeneity. The evaluation of pesticide residues was made in a specific area of municipality of Madrid-Cundinamarca, (Colombia). No residues of the studied analyses were founded

  17. Workshop on methods for siting groundwater monitoring wells: Proceedings

    International Nuclear Information System (INIS)

    Jacobson, E.

    1992-02-01

    The primary purpose of this workshop was to identify methods for the optimum siting of groundwater monitoring wells to minimize the number required that will provide statistically and physically representative samples. In addition, the workshop served to identify information and data gaps, stimulated discussion and provided an opportunity for exchange of ideas between regulators and scientists interested in siting groundwater monitoring wells. These proceedings should serve these objectives and provide a source of relevant information which may be used to evaluate the current state of development of methods for siting groundwater monitoring wells and the additional research needs. The proceedings contain the agenda and list of attendees in the first section. The abstract and viewgraphs for each presentation are given in the second section. For several presentations, abstracts and viewgraphs were not received. After the presentations, four working groups were organized and met for approximately a day. The working group leaders then gave a verbal summary of their sessions. This material was transcribed and is included in the next section of these proceedings. The appendices contain forms describing various methods discussed in the working groups

  18. Monitoring the convection coefficient in fermentative processes using numerical methods.

    Science.gov (United States)

    da Paz, Priscila Marques; de Oliveira, Juliana

    2018-02-13

    This work is based on the importance of monitoring the thermodynamic variables of sugarcane juice fermentation by Saccharomyces cerevisiae, using a numerical technique, and providing artifices that lead to the best performance of this bioprocess. Different combinations of yeast quantity were added to diverse dilutions of cane juice, allowing the evaluation of the fermentation performance. This was conducted by observing the temperature signal obtained from thermal probes inserted in the experimental set up. The best performances are utilized in the mathematical model evaluation. Thus, the signal reconstructed by the appropriate inverse problem and subsequently, regularized by the simplified method of least squares (the method used for adjusting the defined parameters) allows a common method to process the convection coefficient that can be monitored and controlled within an actuation range. This leads to an increased level of refinement in the technique. Results show that it is possible to determine the best parameters for this technique and observe the occurrence of fermentation by monitoring the temperature signal, thereby ensuring the realization of a high-quality and high-performance bioprocess.

  19. Application of the Rietveld method to assess chromium(VI) speciation in chromite ore processing residue.

    Science.gov (United States)

    Chrysochoou, Maria; Dermatas, Dimitris

    2007-03-15

    The Rietveld method allows the quantification of crystalline phases and amorphous material identified by X-ray powder diffraction (XRPD) and other diffraction methods. The method assists in determining the speciation of contaminants in solid matrices both qualitatively and quantitatively in a statistically defensible approach, as it does not focus on a microscale. Rietveld was applied to chromite ore processing residue (COPR), a cementitious waste containing hexavalent chromium. Calcium aluminum chromium oxide hydrates (CACs) were the crystalline phases identified by XRPD that bind Cr(6+) in COPR according to their chemical formula. Rietveld quantification, combined with mass balances on Cr(6+), showed that CACs may bind Cr(6+) in variable percentages, ranging from 25% to 85%. Analysis of duplicate samples showed that material variability is the predominant factor of uncertainty in evaluating the role of CACs in Cr(6+) speciation, provided that a consistent quantification strategy is pursued. The choice of strategy was performed on the basis of the pertinent literature, preliminary analyses of the equipment and the software settings, and mass balances. The correlation between the average CAC-bound Cr(6+) concentration and the total Cr(6+) for five samples (R(2)=0.94), extracted from different zones and soil borings, suggests that CACs are a primary sink for Cr(6+) in COPR.

  20. [Plethysmechanomyography (PMG). A simple method for monitoring muscle relaxation].

    Science.gov (United States)

    Pohlen, G; Ribeiro, F C; Scheiber, G

    1994-12-01

    Ideal evaluation of neuromuscular blockade can be done by mechanical or electromyographical registration of muscle contractions evoked by ulnar nerve stimulation. Unfortunately, devices needed for such registration are expensive or complicated to set up, and thus are not often used for routine monitoring in anaesthesia. In this study, we describe a simple and low-priced method permitting intra- and postoperative monitoring of neuromuscular blocking agents. The accuracy of plethysmomechanomyography (PMG) was evaluated by comparing simultaneous electromyographic (EMG) and plethysmographic measurements. METHODS. For plethysmographic registration of muscle response to nerve stimulation a simple infusion system is twisted there to five times around one hand and connected to an anaesthetic monitor via a pressure transducer. The drip chamber is fixed about 20 cm above the hand (Fig. 1). Then, the infusion system is then filled up-with physiologic saline solution and the clamp is nearly closed. Electric stimulation can be carried out using any nerve stimulator. Using this method, PMG mainly records the contractions of abductor digiti minimi muscle, but also partly those of the interossei. Evoked muscle contractions cause stretching of the infusion system, which leads to pressure changes proportional to the strength of contraction. The muscle response to "train-of-four" (TOF) stimulation of the ulnar nerve was recorded simultaneously by EMG and PMG in 11 patients (ASA class I or II) undergoing neurosurgical procedures and therefore requiring muscle relaxation. After induction of anaesthesia by injection of etomidate and fentanyl, supramaximal stimulation and control values (T0) were defined. Anaesthesia was maintained by supplementation with nitrous oxide/oxygen (1:2) and muscle relaxation was carried out with vecuronium. We used the integrated nerve stimulator of a Datex Relaxograph NMT-100 EMG monitor and proceeded to stimulate the ulnar nerve at the forearm with

  1. Improved Method for Quantifying Nonvolatile Residues on Surfaces and in Liquids

    Energy Technology Data Exchange (ETDEWEB)

    Benkovich, M.G.

    2004-03-30

    The objective of the project was to develop an improved method to quantify nonvolatile residues on surfaces and in liquids. The project accomplishments are summarized below: (1) ERA Systems, Inc., The MESERAN Company has designed, developed, built, evaluated, tested, and delivered MicroSolventEvaporator systems to KCP, Astro Pak, and Lockheed Martin, that automatically deposit and evaporate successive small quantities (5-10 microliters) of solvents onto clean reference surfaces. (2) ERA Systems, Inc., The MESERAN Company, and KCP have designed, procured, and evaluated stainless steel disks with specific machined grooves to be used as reference surfaces with the MicroSolventEvaporator and MESERAN Analyzers. (3) KCP evaluated various cleaning processes to easily clean the reference surfaces to acceptable levels. Even though some methods (or a combination of methods) may have worked better than others, an easy method that most companies could use to acceptably clean the disks was desired. Aqueous ultrasonic cleaning with Dirl Lum 603 (30 g per liter concentration) followed by flowing DI water and ultrasonic DI water rinses, nitrogen blow drying, and baking in a HEPA filtered oven at 220 F for 30 minutes proved to be a relatively simple method that most companies could use. (4) KCP developed calibrations of several contaminants on the chosen reference substrates so the MESERAN data could be converted into quantifiable amounts of contamination. (5) KCP performed a prove-in of the MicroSolventEvaporator in conjunction with the MESERAN Analyzer and compared the results to gravimetric data. The method worked and was able to provide data at low contamination levels that can not be reliably obtained gravimetrically. (6) Astro Pak and Lockheed Martin have done limited testing at their facilities. The MESERAN Company has agreed to let them keep the units for awhile so they can continue to perform tests to prove-in the process at their facilities even after the CRADA is

  2. Efficient diagnostic methods for nuclear power plant monitoring

    International Nuclear Information System (INIS)

    Sunder, R.

    1997-01-01

    There are systems for operational monitoring of vibrations, valves, solid-borne sound, leaks, and embrittlement. The paper focuses on vibration monitoring of pressurized components and systems in PWRs and BWRs. Other than with conventional systems, the task is not to globally monitor the vibration level, but the frequency-selective information is used as a sensitive information source, the level of vibrations being of secondary significance. The essential feature therefore is the comprehensive and selective scanning of individual frequency components in the recorded vibration spectra, which in some cases can be less than a millesimal millimeter. Upon identification of the various vibration components - from so-called baseline analyses using correlation methods - vibration analysis is done by only one step, comparing a defined reference state with the actual vibration state of the monitored system component. In the event of detected deviations, information on the causes of vibrations - essentially component-related structural resonances - will give the relevant cause-effect relationship. The paper uses some practical examples to illustrate that reliable diagnoses are achieved by the above-mentioned frequency-selective technique. It is important, however, to carry out a sufficiently reliable statistical verification of diagnostic data by means of vibration trending. This is ensured with the digital systems and their high data acquisition rates. (orig./CB) [de

  3. Methodics of computing the results of monitoring the exploratory gallery

    Directory of Open Access Journals (Sweden)

    Krúpa Víazoslav

    2000-09-01

    Full Text Available At building site of motorway tunnel Višòové-Dubná skala , the priority is given to driving of exploration galley that secures in detail: geologic, engineering geology, hydrogeology and geotechnics research. This research is based on gathering information for a supposed use of the full profile driving machine that would drive the motorway tunnel. From a part of the exploration gallery which is driven by the TBM method, a fulfilling information is gathered about the parameters of the driving process , those are gathered by a computer monitoring system. The system is mounted on a driving machine. This monitoring system is based on the industrial computer PC 104. It records 4 basic values of the driving process: the electromotor performance of the driving machine Voest-Alpine ATB 35HA, the speed of driving advance, the rotation speed of the disintegrating head TBM and the total head pressure. The pressure force is evaluated from the pressure in the hydraulic cylinders of the machine. Out of these values, the strength of rock mass, the angle of inner friction, etc. are mathematically calculated. These values characterize rock mass properties as their changes. To define the effectivity of the driving process, the value of specific energy and the working ability of driving head is used. The article defines the methodics of computing the gathered monitoring information, that is prepared for the driving machine Voest – Alpine ATB 35H at the Institute of Geotechnics SAS. It describes the input forms (protocols of the developed method created by an EXCEL program and shows selected samples of the graphical elaboration of the first monitoring results obtained from exploratory gallery driving process in the Višòové – Dubná skala motorway tunnel.

  4. Process control monitoring systems, industrial plants, and process control monitoring methods

    Science.gov (United States)

    Skorpik, James R [Kennewick, WA; Gosselin, Stephen R [Richland, WA; Harris, Joe C [Kennewick, WA

    2010-09-07

    A system comprises a valve; a plurality of RFID sensor assemblies coupled to the valve to monitor a plurality of parameters associated with the valve; a control tag configured to wirelessly communicate with the respective tags that are coupled to the valve, the control tag being further configured to communicate with an RF reader; and an RF reader configured to selectively communicate with the control tag, the reader including an RF receiver. Other systems and methods are also provided.

  5. Analytical method for the determination of cyromazine and melamine residues in soil using LC-UV and GC-MSD.

    Science.gov (United States)

    Yokley, R A; Mayer, L C; Rezaaiyan, R; Manuli, M E; Cheung, M W

    2000-08-01

    A method is reported for the determination of cyromazine and melamine residues in soil. Soil samples are extracted twice via mechanical shaking, each time with 70% acetonitrile/30% 0.050 M ammomium carbonate for 30 min. An aliquot portion of the pooled extracts is subjected to strong cation exchange (SCX) purification on AG 50W-X4 resin. Final analysis is accomplished using liquid chromatography-ultraviolet (LC-UV) detection at a wavelength of 214 nm. Confirmatory analyses can be performed using gas chromatography-mass selective detection (GC-MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 2.5 ng injected and the limit of quantification (LOQ) is 10 ppb when using LC-UV for the analysis of N-cyclopropyl-1,3,5-triazine-2,4, 6-triamine (cyromazine) and 1,3,5-triazine-2,4,6-triamine (melamine). The LOD is 0.050 ng injected and the LOQ is 10 ppb when using GC-MSD for confirmatory analyses. The mean procedural recoveries were 97 and 95% and the standard deviations were 16 and 11% for cyromazine and melamine, respectively (n = 24), when using LC-UV. The mean procedural recoveries were 107 and 92% and the standard deviations were 9.9 and 16% for cyromazine and melamine, respectively (n = 29), when using GC-MSD. The method validation study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160. The method also passed an Independent Laboratory Validation (ILV) as per U.S. EPA FIFRA Subdivision N.

  6. Application of Trend Detection Methods in Monitoring Physiological Signals

    Directory of Open Access Journals (Sweden)

    William W. Melek

    2004-12-01

    Full Text Available This paper presents a comparative study of various trend detection methods developed using fuzzy logic, statistical, and regression techniques. A new method that uses noise rejection fuzzy clustering is also proposed in the paper to enhance the performance of trend detection methodologies. The comparative investigation has produced systematic guidelines for the selection of a proper trend detection method for different application requirements. This paper has resulted from work on military applications of on-line trend analysis, such as monitoring of wounded soldiers by first-response medical staff at the battlefield and high-acceleration protection of fighter jet pilots. Efficient trend detection methods can provide early warnings, severity assessments of a subject's physiological state, and decision support for firstresponse medical attendants. Representative physiological variables such as blood pressure, heartbeat rate, and ear opacity are considered in this paper.

  7. Minimization and Mitigation of Wire EDM Cutting Errors in the Application of the Contour Method of Residual Stress Measurement

    Science.gov (United States)

    Ahmad, Bilal; Fitzpatrick, Michael E.

    2016-01-01

    The contour method of residual stress measurement relies on the careful application of wire electro-discharge machining (WEDM) for the cutting stage. Changes in material removal rates during the cut lead to errors in the final calculated values of residual stress. In this study, WEDM cutting parameters have been explored to identify the optimum conditions for contour method residual stress measurements. The influence of machine parameters on the surface roughness and cutting artifacts in the contour cut is discussed. It has been identified that the critical parameter in improving the surface finish is the spark pulse duration. A typical cutting artifact and its impact on measured stress values have been identified and demonstrated for a contour cut in a welded marine steel. A procedure is presented to correct contour displacement data from the influence of WEDM cutting artifacts, and is demonstrated on the correction of a measured weld residual stress. The corrected contour method improved the residual stress magnitude up to 150 MPa. The corrected contour method results were validated by X-ray diffraction, incremental center hole drilling, and neutron diffraction.

  8. Disinfectant Residual - Representative Monitoring & ...

    Science.gov (United States)

    Presentation to be given at the 12th CECIA-IAUPR Biennial Symposium in Puerto Rico in February 2017. The presentation was also given at the WQTC in Indianapolis on November 14, 2016. To inform the public.

  9. [A smear method for measuring anti-cancer drugs residues in hospitals].

    Science.gov (United States)

    Takano, Takumi; Suzuki, Shigeru; Tsukiyama, Ikuto; Saito, Hiroko

    2015-01-01

    Anti-cancer drugs are harmful to healthy persons. In recent years, occupational exposure to anti-cancer drugs has become a major concern to health care workers. To address this issue, a smear method was developed to measure widely using anti-cancer drugs depositing on the floors, safety cabinet surfaces, and tables in hospital. Ten kinds of widely used anti-cancer drugs, paclitaxel, vincristine, docetaxel, vinorelbine, irinotecan, methotrexate, oxaliplatin, cyclophosphamide, gemcitabine and fluorouracil were collected by smearing material surfaces with methanol impregnated cellulose filter paper and/or polypropylene nonwoven. The collected anti-cancer drugs are extracted in 5 ml of 0.01% (v/v) hydrazine/methanol solution by sonication. The extracted solution was filtered and concentrated to prepare 1ml of sample solution. Then, the anti-cancer drugs in the sample solution were simultaneously measured by LC/MS. The anti-cancer drugs excepting fluorouracil spread on P-tile surface were measured with recoveries of 37-101% and standard deviations (SD) of 1.8-19%. All 10 of the anti-cancer drugs on a stainless steel plate surface were measured with the recoveries of 35-111% and SD of 1.3-11%. Using this smear method, 9 or 10 kinds of widely used anti-cancer drug residues in hospital, possibly exposed to health care workers, were grasped.

  10. A method for determining allowable residual contamination levels of radionuclide mixtures in soil

    International Nuclear Information System (INIS)

    Napier, B.A.

    1982-05-01

    An important consideration in the disposal of radioactive wastes, and consequently in the preparation of plans for remedial actions at contaminated sites, is the amount of radioactive contamination that may be allowed to remain at any particular waste site. The allowable residual contamination level (ARCL) is dependent on the radiation dose limit imposed, the physical and environmental characteristics of the waste site, and the time at which exposure to the wastes is assumed to occur. The steps in generating an ARCL are generally as follows: (1) develop plausible, credible site-specific exposure scenario; (2) calculate maximum annual radiation doses to an individual for each radionuclide based on the existing physical characteristics of the waste site and the site-specific exposure scenario; (3) calculate the ARCL for the dose limit desired, including all radionuclides present, uncorrected for site cleanup or barrier considerations; and (4) apply any corrections for proposed cleanup activity or addition of barriers to waste migration or uptake to obtain the ARCL applicable to the proposed action. Use of this method allows appropriate application of resources to achieve uniform compliance with a single regulatory standard, i.e., a radiation dose rate limit. Application and modification of the ARCL method requires appropriate models of the environmental transport and fate of radionuclides. Example calculations are given for several specific waste forms and waste site types in order to demonstrate the technique and generate comparisons with other approaches

  11. Study of TATP: method for determination of residual acids in TATP.

    Science.gov (United States)

    Matyáš, Robert; Chýlková, Jaromíra

    2013-05-10

    Triacetone triperoxide (3,3,6,6,9,9-hexamethyl-1,2,4,5,7,8-hexoxonane, TATP) is nowadays one of the most commonly used improvised explosives. It is prepared by the action of hydrogen peroxide on acetone in an acidic environment. Easily available mineral acids - hydrochloric, sulfuric, nitric and perchloric - are the most often recommended on the extremist web pages dealing with improvised production of explosives. The various TATP producers' choice of acid mainly depends on the author's experiences and the local availability of the acid. A knowledge of the kind of acid used for TATP production can help in detecting the person who has made the TATP, or who has committed a criminal act using TATP. Therefore, a capillary isotachophoretic method was developed for determination of residual anions (originating from the acid used during TATP synthesis) in the resulting TATP crystals. This analytical method has proved to be reliable; the acid used for TATP synthesis was correctly identified in all samples analyzed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. A direct recursive residue generation method: application to photoionization of hydrogen in static electric fields

    International Nuclear Information System (INIS)

    Karlsson, H.O.; Goscinski, O.

    1994-01-01

    In studies of hydrogenic systems via the recursive residue generation method (RRGM) the major bottleneck is the matrix vector product HC, between the Hamiltonian matrix H and a Lanczos vector C. For highly excited states and/or strong perturbations the size of H grows fast leading to storage problems. By making use of direct methods, i.e. avoidance of explicit construction of large Hamiltonian matrices, such problems can be overcome. Utilizing the underlying analytical properties of the Laguerre basis e -λr L k 2l+2 (2λr) a direct RRGM (D-RRGM) for the unperturbed hydrogenic Hamiltonian is derived, changing the storage needs from scaling as N 2 to 4N where N is the number of radial functions for each factorized H o (l,m) block with the possibility of parallel processing. A further computational simplification is introduced by putting the expression for the photoionization (PI) cross section in the rational form conventionally used in the representation of density of states (DOS). This allows the construction of the PI cross section directly from the tridiagonal Lanczos matrix avoiding the explicit calculation of individual eigen values and eigenvectors. (Author)

  13. Evaluation of methods for monitoring air concentrations of hydrogen sulfide

    Directory of Open Access Journals (Sweden)

    Katarzyna Janoszka

    2013-06-01

    Full Text Available The development of different branches of industry and a growing fossil fuels mining results in a considerable emission of by-products. Major air pollutants are: CO, CO₂, SO₂, SO₃, H₂S, nitrogen oxides, as well as compounds of an organic origin. The main aspects of this paper is to review and evaluate methods used for monitoring of hydrogen sulfide in the air. Different instrumental techniques were discussed, electrochemical, chromatographic and spectrophotometric (wet and dry, to select the method most suitable for monitoring low levels of hydrogen sulfide, close to its odor threshold. Based on the literature review the method for H₂S determination in the air, involving absorption in aqueous zinc acetate and reaction with N,N-dimethylo-p-phenylodiamine and FeCl₃, has been selected and preliminary verified. The adopted method allows for routine measurements of low concentration of hydrogen sulfide, close to its odor threshold in workplaces and ambient air. Med Pr 2013;64(3:449–454

  14. Standard test method for determining the effective elastic parameter for X-ray diffraction measurements of residual stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a procedure for experimentally determining the effective elastic parameter, Eeff, for the evaluation of residual and applied stresses by X-ray diffraction techniques. The effective elastic parameter relates macroscopic stress to the strain measured in a particular crystallographic direction in polycrystalline samples. Eeff should not be confused with E, the modulus of elasticity. Rather, it is nominally equivalent to E/(1 + ν) for the particular crystallographic direction, where ν is Poisson's ratio. The effective elastic parameter is influenced by elastic anisotropy and preferred orientation of the sample material. 1.2 This test method is applicable to all X-ray diffraction instruments intended for measurements of macroscopic residual stress that use measurements of the positions of the diffraction peaks in the high back-reflection region to determine changes in lattice spacing. 1.3 This test method is applicable to all X-ray diffraction techniques for residual stress measurem...

  15. Landslide Geohazard Monitoring, Early Warning and Stabilization Control Methods

    Science.gov (United States)

    Bednarczyk, Zbigniew

    2014-03-01

    This paper is a presentation of landslide monitoring, early warning and remediation methods recommended for the Polish Carpathians. Instrumentation included standard and automatic on-line measurements with the real-time transfer of data to an Internet web server. The research was funded through EU Innovative Economy Programme and also by the SOPO Landslide Counteraction Project. The landslides investigated were characterized by relatively low rates of the displacements. These ranged from a few millimetres to several centimetres per year. Colluviums of clayey flysch deposits were of a soil-rock type with a very high plasticity and moisture content. The instrumentation consisted of 23 standard inclinometers set to depths of 5-21 m. The starting point of monitoring measurements was in January 2006. These were performed every 1-2 months over the period of 8 years. The measurements taken detected displacements from several millimetres to 40 cm set at a depth of 1-17 m. The modern, on-line monitoring and early warning system was installed in May 2010. The system is the first of its kind in Poland and only one of several such real-time systems in the world. The installation was working with the Local Road Authority in Gorlice. It contained three automatic field stations for investigation of landslide parameters to depths of 12-16 m and weather station. In-place tilt transducers and innovative 3D continuous inclinometer systems with sensors located every 0.5 m were used. It has the possibility of measuring a much greater range of movements compared to standard systems. The conventional and real-time data obtained provided a better recognition of the triggering parameters and the control of geohazard stabilizations. The monitoring methods chosen supplemented by numerical modelling could lead to more reliable forecasting of such landslides and could thus provide better control and landslide remediation possibilities also to stabilization works which prevent landslides.

  16. Landslide Geohazard Monitoring, Early Warning and Stabilization Control Methods

    Directory of Open Access Journals (Sweden)

    Bednarczyk Zbigniew

    2014-03-01

    Full Text Available This paper is a presentation of landslide monitoring, early warning and remediation methods recommended for the Polish Carpathians. Instrumentation included standard and automatic on-line measurements with the real-time transfer of data to an Internet web server. The research was funded through EU Innovative Economy Programme and also by the SOPO Landslide Counteraction Project. The landslides investigated were characterized by relatively low rates of the displacements. These ranged from a few millimetres to several centimetres per year. Colluviums of clayey flysch deposits were of a soil-rock type with a very high plasticity and moisture content. The instrumentation consisted of 23 standard inclinometers set to depths of 5-21 m. The starting point of monitoring measurements was in January 2006. These were performed every 1-2 months over the period of 8 years. The measurements taken detected displacements from several millimetres to 40 cm set at a depth of 1-17 m. The modern, on-line monitoring and early warning system was installed in May 2010. The system is the first of its kind in Poland and only one of several such real-time systems in the world. The installation was working with the Local Road Authority in Gorlice. It contained three automatic field stations for investigation of landslide parameters to depths of 12-16 m and weather station. In-place tilt transducers and innovative 3D continuous inclinometer systems with sensors located every 0.5 m were used. It has the possibility of measuring a much greater range of movements compared to standard systems. The conventional and real-time data obtained provided a better recognition of the triggering parameters and the control of geohazard stabilizations. The monitoring methods chosen supplemented by numerical modelling could lead to more reliable forecasting of such landslides and could thus provide better control and landslide remediation possibilities also to stabilization works which

  17. [Determination of 51 carbamate pesticide residues in vegetables by liquid chromatography-tandem mass spectrometry based on optimization of QuEChERS sample preparation method].

    Science.gov (United States)

    Wang, Lianzhu; Zhou, Yu; Huang, Xiaoyan; Wang, Ruilong; Lin, Zixu; Chen, Yong; Wang, Dengfei; Lin, Dejuan; Xu, Dunming

    2013-12-01

    The raw extracts of six vegetables (tomato, green bean, shallot, broccoli, ginger and carrot) were analyzed using gas chromatography-mass spectrometry (GC-MS) in full scan mode combined with NIST library search to confirm main matrix compounds. The effects of cleanup and adsorption mechanisms of primary secondary amine (PSA) , octadecylsilane (C18) and PSA + C18 on co-extractives were studied by the weight of evaporation residue for extracts before and after cleanup. The suitability of the two versions of QuEChERS method for sample preparation was evaluated for the extraction of 51 carbamate pesticides in the six vegetables. One of the QuEChERS methods was the original un-buffered method published in 2003, and the other was AOAC Official Method 2007.01 using acetate buffer. As a result, the best effects were obtained from using the combination of C18 and PSA for extract cleanup in vegetables. The acetate-buffered version was suitable for the determination of all pesticides except dioxacarb. Un-buffered QuEChERS method gave satisfactory results for determining dioxacarb. Based on these results, the suitable QuEChERS sample preparation method and liquid chromatography-positive electrospray ionization-tandem mass spectrometry under the optimized conditions were applied to determine the 51 carbamate pesticide residues in six vegetables. The analytes were quantified by matrix-matched standard solution. The recoveries at three levels of 10, 20 and 100 microg/kg spiked in six vegetables ranged from 58.4% to 126% with the relative standard deviations of 3.3%-26%. The limits of quantification (LOQ, S/N > or = 10) were 0.2-10 microg/kg except that the LOQs of cartap and thiofanox were 50 microg/kg. The method is highly efficient, sensitive and suitable for monitoring the 51 carbamate pesticide residues in vegetables.

  18. A study on the neoasozine residues in rice grain by neutron activation method

    International Nuclear Information System (INIS)

    Kim, Y.H.; Lee, K.J.; Lee, S.R.

    1981-01-01

    Residues of neoasozine in rice grain were determined by neutron activation and colorimetric techniques. Twice application of the chemical before flowering did not lead to any increased residue level while 4-times application resulted in significant increase in the residue level up to 0.54 - 0.75 mg As 2 O 3 /kg. The partition ratio of arsenic residues into polished rice grain and bran was 73 : 27 in 100 % polishing while most of the residues in the bran was transferred to oil cake fraction during solvent extraction, reaching up to 2.9 mg As 2 O 3 /kg. The neutron activation technique was advantageous because of its high sensitivity and the smaller sample amounts required for analysis. (author)

  19. 77 FR 55832 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method

    Science.gov (United States)

    2012-09-11

    ... equivalent method determination for the PM 2.5 method was received by the Office of Research and Development... Assurance Handbook for Air Pollution Measurement Systems, Volume I,'' EPA/600/R-94/038a and ``Quality Assurance Handbook for Air Pollution Measurement Systems, Volume II, Ambient Air Quality Monitoring Program...

  20. Residual nilpotence and residual solubility of groups

    International Nuclear Information System (INIS)

    Mikhailov, R V

    2005-01-01

    The properties of the residual nilpotence and the residual solubility of groups are studied. The main objects under investigation are the class of residually nilpotent groups such that each central extension of these groups is also residually nilpotent and the class of residually soluble groups such that each Abelian extension of these groups is residually soluble. Various examples of groups not belonging to these classes are constructed by homological methods and methods of the theory of modules over group rings. Several applications of the theory under consideration are presented and problems concerning the residual nilpotence of one-relator groups are considered.

  1. Validation of an HPLC–UV method for the determination of digoxin residues on the surface of manufacturing equipment

    Directory of Open Access Journals (Sweden)

    ZORAN B. TODOROVIĆ

    2009-09-01

    Full Text Available In the pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC–UV method for the determination of digoxin residues on stainless steel surfaces was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with methanol were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 85.9, 85.2 and 78.7 % for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD, were below 6.3 %. The method was validated over a concentration range of 0.05–12.5 µg mL-1. Low quantities of drug residues were determined by HPLC–UV using a Symmetry C18 column (150´4.6 mm, 5 µm at 20 °C with an acetonitrile–water (28:72, v/v mobile phase at a flow rate of 1.1 mL min-1, an injection volume of 100 µL and were detected at 220 nm. A simple, selective and sensitive HPLC–UV assay for the determination of digoxin residues on stainless steel was developed, validated and applied.

  2. An accurate method for determining residual stresses with magnetic non-destructive techniques in welded ferromagnetic steels

    Science.gov (United States)

    Vourna, P.

    2016-03-01

    The scope of the present research work was to investigate the proper selection criteria for developing a suitable methodology for the accurate determination of residual stresses existing in welded parts. Magnetic non-destructive testing took place by the use of two magnetic non-destructive techniques: by the measurement of the magnetic Barkhausen noise and by the evaluation of the magnetic hysteresis loop parameters. The spatial distribution of residual stresses in welded metal parts by both non-destructive magnetic methods and two diffraction methods was determined. The conduction of magnetic measurements required an initial calibration of ferromagnetic steels. Based on the examined volume of the sample, all methods used were divided into two large categories: the first one was related to the determination of surface residual stress, whereas the second one was related to bulk residual stress determination. The first category included the magnetic Barkhausen noise and the X-ray diffraction measurements, while the second one included the magnetic permeability and the neutron diffraction data. The residual stresses determined by the magnetic techniques were in a good agreement with the diffraction ones.

  3. Residual Stress Analysis of Severe Plastic Deformed Materials using the Finite Element Method and the Neutron Diffraction Method

    International Nuclear Information System (INIS)

    Kang, Mi Hyun; Seong, Back Suck; Kim, Hyoung Seop

    2009-01-01

    Severe plastic deformation (SPD) is one of the most promising top-down techniques, moving towards industrialization to fabricate bulk ultrafine grain materials. The strain distribution and deformation behavior during the ECAP (equal channel angular pressing), influenced by tool angles, friction and material behavior, was studied through experimental and numerical analyses. The residual stress of work piece which was straight before ECAP produces many serious problems in the next processing e.g. input of the work piece for the next ECAP. The bent work piece needs additional straightening or surface polishing even if the amount of bending is small, and residual stress need to be released before service applications. Residual stress, particularly tensile residual stress can be a very important factor in affecting the reliability and integrity of working parts. The formation of tensile residual stress may result in initiation of fatigue cracks, stress corrosion cracking, or other types of fracture. Hence, residual stress and resulting bending need to be controlled during ECAP. Thus, in current study the bending behavior and the residual stress of the work piece in ECAP are analyzed through experimental and finite element analyses by considering the effects of material, geometric, and processing parameters individually. The stress states in the ECAP processed work piece were measured by the non-destructive way using neutron diffraction. Efforts were made to suggest the alternate routes to reduce the residual stress and bending of work piece in ECAP

  4. Algorithms for monitoring warfarin use: Results from Delphi Method.

    Science.gov (United States)

    Kano, Eunice Kazue; Borges, Jessica Bassani; Scomparini, Erika Burim; Curi, Ana Paula; Ribeiro, Eliane

    2017-10-01

    Warfarin stands as the most prescribed oral anticoagulant. New oral anticoagulants have been approved recently; however, their use is limited and the reversibility techniques of the anticoagulation effect are little known. Thus, our study's purpose was to develop algorithms for therapeutic monitoring of patients taking warfarin based on the opinion of physicians who prescribe this medicine in their clinical practice. The development of the algorithm was performed in two stages, namely: (i) literature review and (ii) algorithm evaluation by physicians using a Delphi Method. Based on the articles analyzed, two algorithms were developed: "Recommendations for the use of warfarin in anticoagulation therapy" and "Recommendations for the use of warfarin in anticoagulation therapy: dose adjustment and bleeding control." Later, these algorithms were analyzed by 19 medical doctors that responded to the invitation and agreed to participate in the study. Of these, 16 responded to the first round, 11 to the second and eight to the third round. A 70% consensus or higher was reached for most issues and at least 50% for six questions. We were able to develop algorithms to monitor the use of warfarin by physicians using a Delphi Method. The proposed method is inexpensive and involves the participation of specialists, and it has proved adequate for the intended purpose. Further studies are needed to validate these algorithms, enabling them to be used in clinical practice.

  5. On time monitoring method for nuclear power plant

    International Nuclear Information System (INIS)

    Nabeshima, Kunihiko; Suzuki, Katsuo; Tuerkcan, E.; Ciftcioglu, O.

    1997-01-01

    The present invention provides a method of modeling a nuclear power plant by using a neural network thereby rapidly monitoring a slight symptom of abnormality on time through the entire operation time period from the start-up to the shut down of the nuclear power plant. Namely, measured data (signals) of at least two plant parameters among neutron flux, temperature, pressure, quantity of water and electric power obtained from the nuclear power plant are compared with estimated data obtained by utilizing the neural network comprising an initial leaning and application learning. When the difference between both of them exceeds a threshold value, the power plant is judged to be abnormal. According to this invention, since a plant model is constituted by a neural network different from a one-dimensional physical model by using major plant parameters of the reactor, and the difference between the actually measured data (signals) and estimated values by using the model is monitored, accordingly, slight symptom of abnormality can be monitored with less erroneous operation on time over a wide range from the start-up to the shut down in an early stage. (I.S.)

  6. Development and primary application of ELISA method for detecting residual calf serum protein

    International Nuclear Information System (INIS)

    Li Hua; Yu Jiankun; Hong Chao; Long Ruixiang; Zhai Yougang; Xu Qiongfang; Cui Pingfang; Ding Xuefeng; Xie Zhongping

    2005-01-01

    To develop a new DAS-ELISA (double antibody sandwich ELISA) kit for detecting residual calf serum protein (CSP) in vaccines, calf sera from different district were pooled and used to immunize rabbits and hens respectively. Then, the IgY from yolk and the anti-CSP IgG from rabbit were separated and purified. The purified IgY was used as the coating antibody, and purified rabbit anti-CSP IgG was labeled by HRP. The optimal concentration of IgY was 25-30 μg/mL. The coating buffer was 0.01mol/L PBS(pH7.4) containing 0.4% glutin. The optimal dilutions of HRP-IgG were from 1:2000 to 1:3000. The sensitivity of this ELISA method was higher (up to 2.5μg/mL) than that of current RPHA, the variation coefficient was about 6.3%-9.4%, and the recovery rate was 90.4%-112.8%. Furthermore, there was no cross-reaction with sera of pig, monkey and guinea pig. Twenty lots of vaccines with Al(OH) 3 or without Al(OH) 3 were tested by ELISA and RPHA respectively. The results proved that the adjuvant of Al(OH) 3 had fewer influence on ELISA than on RPHA, the variation of PRHA among different lots of vaccines was more significant than ELISA. The ELISA method is a highly sensitive and useful method to detect CSP in vaccines. (authors)

  7. Method of monitoring, inspecting or testing conveyor belts

    International Nuclear Information System (INIS)

    Van der Walt, A.J.

    1985-01-01

    An invention is discussed which provides a method, installation and kit for monitoring, inspecting or testing a conveyor belt. Provision is made to transmit penetrating rays such as X-rays through a moving conveyor belt, forming a visible moving image from rays transmitted through the belt, and visually inspecting such moving image, after recording it if desired, to ascertain the condition of the interior of the belt. Typically an X-ray tube head is used to transmit the rays through the belt to a fluorescent screen which forms the image. The moving image can be recorded by means of a video camera

  8. Imaging method for monitoring delivery of high dose rate brachytherapy

    Science.gov (United States)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  9. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Computation of point reactor dynamics equations with thermal feedback via weighted residue method

    International Nuclear Information System (INIS)

    Suo Changan; Liu Xiaoming

    1986-01-01

    Point reactor dynamics equations with six groups of delayed neutrons have been computed via weighted-residual method in which the delta function was taken as a weighting function, and the parabolic with or without exponential factor as a trial function respectively for an insertion of large or smaller reactivity. The reactivity inserted into core can be varied with time, including insertion in forms of step function, polynomials up to second power and sine function. A thermal feedback of single flow channel model was added in. The thermal equations concerned were treated by use of a backward difference technique. A WRK code has been worked out, including implementation of an automatic selection of time span based on an input of error requirement and of an automatic change between computation with large reactivity and that with smaller one. On the condition of power varied slowly and without feedback, the results are not sensitive to the selection of values of time span. At last, the comparison of relevant results has shown that the agreement is quite well

  11. Prediction of Gas Chromatography-Mass Spectrometry Retention Times of Pesticide Residues by Chemometrics Methods

    Directory of Open Access Journals (Sweden)

    Elaheh Konoz

    2013-01-01

    Full Text Available A quantitative structure-retention relationships (QSRRs method is employed to predict the retention time of 300 pesticide residues in animal tissues separated by gas chromatography-mass spectroscopy (GC-MS. Firstly, a six-parameter QSRR model was developed by means of multiple linear regression. The six molecular descriptors that were considered to account for the effect of molecular structure on the retention time are number of nitrogen, Solvation connectivity index-chi 1, Balaban Y index, Moran autocorrelation-lag 2/weighted by atomic Sanderson electronegativity, total absolute charge, and radial distribution function-6.0/unweighted. A 6-7-1 back propagation artificial neural network (ANN was used to improve the accuracy of the constructed model. The standard error values of ANN model for training, test, and validation sets are 1.559, 1.517, and 1.249, respectively, which are less than those obtained reveals by multiple linear regressions model (2.402, 1.858, and 2.036, resp.. Results obtained the reliability and good predictability of nonlinear QSRR model to predict the retention time of pesticides.

  12. Properties of nanocellulose isolated from corncob residue using sulfuric acid, formic acid, oxidative and mechanical methods.

    Science.gov (United States)

    Liu, Chao; Li, Bin; Du, Haishun; Lv, Dong; Zhang, Yuedong; Yu, Guang; Mu, Xindong; Peng, Hui

    2016-10-20

    In this work, nanocellulose was extracted from bleached corncob residue (CCR), an underutilized lignocellulose waste from furfural industry, using four different methods (i.e. sulfuric acid hydrolysis, formic acid (FA) hydrolysis, 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-mediated oxidation, and pulp refining, respectively). The self-assembled structure, morphology, dimension, crystallinity, chemical structure and thermal stability of prepared nanocellulose were investigated. FA hydrolysis produced longer cellulose nanocrystals (CNCs) than the one obtained by sulfuric acid hydrolysis, and resulted in high crystallinity and thermal stability due to its preferential degradation of amorphous cellulose and lignin. The cellulose nanofibrils (CNFs) with fine and individualized structure could be isolated by TEMPO-mediated oxidation. In comparison with other nanocellulose products, the intensive pulp refining led to the CNFs with the longest length and the thickest diameter. This comparative study can help to provide an insight into the utilization of CCR as a potential source for nanocellulose production. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Evaluation of sodium hydrosulfite residue in sugar crop in Zanjan province and investigation the new alternative method for determination

    Directory of Open Access Journals (Sweden)

    M Mohseni

    2015-02-01

    Full Text Available Sodium hydrosulfite/blanket is used as a decolorizing agent for the bleaching of produced sugar in the sugar industry. Due to sensitivity of using this chemical substance with defined allowed range in sugar product, the sensitive and exact method of voltammetry/polarography was used to measure the residual blanket in this product and moreover, its results were compared with titration method as a common method for measurement of this substance in reference laboratories. Among the active sugar plants in Zanjan province, three different samples of loaf sugar batch were selected from each production unit based on sampling method of Standard and Industrial Research of Iran and all samples were evaluated using polarography 797 VA Computrace. Then, some of the samples evaluated by the polarography method were also checked with titration method and the results of the two methods were compared with each other. Statistical analysis of obtained data from polarography method shows that various sugar factories have different average sugar content values in blanket residual. Comparative system shows that titration method gives a more than usual response to the amount of blanket residual. Polarography method shows that the dithionite content in the samples ranged from

  14. Displacement Monitoring and Sensitivity Analysis in the Observational Method

    Science.gov (United States)

    Górska, Karolina; Muszyński, Zbigniew; Rybak, Jarosław

    2013-09-01

    This work discusses the fundamentals of designing deep excavation support by means of observational method. The effective tools for optimum designing with the use of the observational method are both inclinometric and geodetic monitoring, which provide data for the systematically updated calibration of the numerical computational model. The analysis included methods for selecting data for the design (by choosing the basic random variables), as well as methods for an on-going verification of the results of numeric calculations (e.g., MES) by way of measuring the structure displacement using geodetic and inclinometric techniques. The presented example shows the sensitivity analysis of the calculation model for a cantilever wall in non-cohesive soil; that analysis makes it possible to select the data to be later subject to calibration. The paper presents the results of measurements of a sheet pile wall displacement, carried out by means of inclinometric method and, simultaneously, two geodetic methods, successively with the deepening of the excavation. This work includes also critical comments regarding the usefulness of the obtained data, as well as practical aspects of taking measurement in the conditions of on-going construction works.

  15. Tailoring diffraction technique Rietveld method on residual stress measurements of cold-can oiled 304 stainless steel plates

    International Nuclear Information System (INIS)

    Parikin; Killen, P.; Anis, M.

    2003-01-01

    Tailoring of diffraction technique-Rietveld method on residual stress measurements of cold-canailed stainless steel 304 plates assuming the material is isotopic, the residual stress measurements using X-ray powder diffraction is just performed for a plane lying in a large angle. For anisotropic materials, the real measurements will not be represented by the methods. By Utilizing of all diffraction peaks in the observation region, tailoring diffraction technique-Rietveld analysis is able to cover the limitations. The residual stress measurement using X-ray powder diffraction tailored by Rietveld method, in a series of cold-canailed stainless steel 304 plates deforming; 0, 34, 84, 152, 158, 175, and 196 % reduction in thickness, have been reported. The diffraction data were analyzed by using Rietveld structure refinement method. Also, for all cold-canailed stainless steel 304 plates cuplikans, the diffraction peaks are broader than the uncanailed one, indicating that the strains in these cuplikans are inhomogeneous. From an analysis of the refined peak shape parameters, the average root-mean square strain, which describes the distribution of the inhomogeneous strain field, was calculated. Finally, the average residual stresses in cold-canailed stainless steel 304 plates were shown to be a combination effect of hydrostatic stresses of martensite particles and austenite matrix. The average residual stresses were evaluated from the experimentally determined average lattice strains in each phase. It was found the tensile residual stress in a cuplikan was maximum, reaching 442 MPa, for a cuplikan reducing 34% in thickness and minimum for a 196% cuplikan

  16. A Simple Surface-Enhanced Raman Spectroscopic Method for on-Site Screening of Tetracycline Residue in Whole Milk

    Directory of Open Access Journals (Sweden)

    Sagar Dhakal

    2018-02-01

    Full Text Available Therapeutic and subtherapeutic use of veterinary drugs has increased the risk of residue contamination in animal food products. Antibiotics such as tetracycline are used for mastitis treatment of lactating cows. Milk expressed from treated cows before the withdrawal period has elapsed may contain tetracycline residue. This study developed a simple surface-enhanced Raman spectroscopic (SERS method for on-site screening of tetracycline residue in milk and water. Six batches of silver colloid nanoparticles were prepared for surface enhancement measurement. Milk-tetracycline and water-tetracycline solutions were prepared at seven concentration levels (1000, 500, 100, 10, 1, 0.1, and 0.01 ppm and spiked with silver colloid nanoparticles. A 785 nm Raman spectroscopic system was used for spectral measurement. Tetracycline vibrational modes were observed at 1285, 1317 and 1632 cm−1 in water-tetracycline solutions and 1322 and 1621 cm−1 (shifted from 1317 and 1632 cm−1, respectively in milk-tetracycline solutions. Tetracycline residue concentration as low as 0.01 ppm was detected in both the solutions. The peak intensities at 1285 and 1322 cm−1 were used to estimate the tetracycline concentrations in water and milk with correlation coefficients of 0.92 for water and 0.88 for milk. Results indicate that this SERS method is a potential tool that can be used on-site at field production for qualitative and quantitative detection of tetracycline residues.

  17. The effect of peritoneal dialysis method on residual renal function in children.

    Science.gov (United States)

    Roszkowska-Blaim, Maria; Skrzypczyk, Piotr; Jander, Anna; Tkaczyk, Marcin; Bałasz-Chmielewska, Irena; Zurowska, Aleksandra; Drozdz, Dorota; Pietrzyk, Jacek A

    2012-01-01

    We set out to assess the effect of continuous ambulatory peritoneal dialysis (CAPD) and automated peritoneal dialysis (APD) on residual renal function (RRF) in children with end-stage renal disease (ESRD). In 101 children (age: 8.84 +/- 5.25 years; 44 on CAPD, 57 on APD) over 36 months, we evaluated RRF [as daily diuresis (DD) in mL/kg/24 h and mL/m2/24 h], glomerular filtration rate [GFR (in mL/min/1.73 m2)], ESRD cause, presence of arterial hypertension (HTN), biochemical parameters, peritoneal equilibration test (PET), adequacy [as total weekly Kt/V (twKt/V) and creatinine clearance (twCCr)], and infectious complications of PD. Initially, the CAPD and APD groups did not differ significantly in DD, but mean GFR was significantly higher in the APD group (p uremic syndrome (HUS) and hereditary nephropathy were at the highest anuria risk. Compared with the 22 children (7 CAPD, 15 APD) who became anuric, the 20 children (10 CAPD, 10 APD) with RRF preserved for 36 months had a higher DD and GFR before dialysis onset; higher hemoglobin and albumin; and lower HTN prevalence, cholesterol, triglycerides, and proteinuria (p dialysis onset, HTN, anemia, hypoalbuminemia, hyperlipidemia, and proteinuria. Compared with children on APD, those on CAPD show better preservation of RRF during year 1, although the risk of anuria seems to be the same for both methods. In children with risk factors for rapid diuresis loss, CAPD might be considered the preferred initial dialysis method.

  18. Groundwater contamination monitoring with multichannel electrical and electromagnetic methods

    Science.gov (United States)

    Buselli, G.; Lu, Kanglin

    2001-08-01

    Electrical and ground-based electromagnetic surveys have been carried out at the Ranger minesite in the Northern Territory, Australia to investigate their use in detecting any seepage from structures used to store ore processing tailings. The main aim of this work has been to develop a clearer understanding of any seepage problems at this minesite using a combination of self-potential (SP), direct current (DC) resistivity, induced polarisation (IP), and transient electromagnetic (TEM) methods, with the results being interpreted in conjunction with hydrogeological data. Ultimately, it is aimed to apply an optimal combination of the methods to long-term monitoring of potential seepage. A 64-channel system developed at the Cooperative Research Centre for Australian Mineral Exploration Technologies (CRC AMET) has been used to record simultaneously the response at a number of electrodes with the SP, DC resistivity and IP methods. A 2D array of electrodes was set up to monitor the SP response over an area measuring 200×300 m. The simultaneous measurements enable time-varying telluric noise associated with SP responses to be minimised. In-line array DC resistivity and IP measurements were made efficiently at 10-m station intervals with the multichannel system, e.g. complete Schlumberger soundings centred at 30 separate stations were made in approximately half a day. Data collected in October and December 1998 north of the Ranger minesite tailings dam are the first of a long-term project, in which changes of responses will be monitored. A trend of increasing chargeability is observed towards a fault that is the main path of any seepage from the tailings dam. At this stage, maps of the SP response measured with the 2D array at different times indicate that the results are reproducible, and there is an association of an SP anomaly with the presence of seepage in an intersection of two faults. It appears that the IP and SP methods offer the best possibility for the direct

  19. Operation monitoring and protection method for nuclear reactor

    International Nuclear Information System (INIS)

    Tochihara, Hiroshi.

    1995-01-01

    In an operation and monitoring method for a PWR-type reactor by using a tetra-sected neutron detector, axial off set is defined by neutron detector signals with respect to an average of the reactor core, the upper half of the reactor core, and the lower half of the reactor core. A departure from nucleate boiling (DNBR) is represented by standardized signals, and the DNBR is calculated by using the axial off set of the average of the reactor core, the upper half of the reactor core, and the lower half of the reactor core, and they are graphically displayed. In addition, a thermal flow rate-water channel coefficient is also graphically displayed, and the DNBR and the thermal flow rate-water channel coefficient are restricted based on the display, to determine an allowable operation range. As a result, it is possible to provide an operation monitoring and protection method for nuclear reactor capable of reducing labors and frequencies for the change of protection system setting in a case of using a tetra-sected neutron detector disposed at the outside and, at the same time, protecting each of DNR and the highest linear power or the thermal water coefficient channel. (N.H.)

  20. Physical Fault Injection and Monitoring Methods for Programmable Devices

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00510096; Ferencei, Jozef

    A method of detecting faults for evaluating the fault cross section of any field programmable gate array (FPGA) was developed and is described in the thesis. The incidence of single event effects in FPGAs was studied for different probe particles (proton, neutron, gamma) using this method. The existing accelerator infrastructure of the Nuclear Physics Institute in Rez was supplemented by more sensitive beam monitoring system to ensure that the tests are done under well defined beam conditions. The bit cross section of single event effects was measured for different types of configuration memories, clock signal phase and beam energies and intensities. The extended infrastructure served also for radiation testing of components which are planned to be used in the new Inner Tracking System (ITS) detector of the ALICE experiment and for selecting optimal fault mitigation techniques used for securing the design of the FPGA-based ITS readout unit against faults induced by ionizing radiation.

  1. Intra-operative hearing monitoring methods in middle ear surgeries

    Directory of Open Access Journals (Sweden)

    Wei Ren

    2016-12-01

    Full Text Available Hearing loss is a condition affecting millions of people worldwide. Conductive hearing loss (CHL is mainly caused by middle ear diseases. The low frequency area is the pivotal part of speech frequencies and most frequently impaired in patients with CHL. Among various treatments of CHL, middle ear surgery is efficient to improve hearing. However, variable success rates and possible needs for prolonged revision surgery still frustrate both surgeons and patients. Nowadays, increasing numbers of researchers explore various methods to monitor the efficacy of ossicular reconstruction intraoperatively, including electrocochleography (ECochG, auditory brainstem response (ABR, auditory steady state response (ASSR, distortion product otoacoustic emissions (DPOAE, subjective whisper test, and optical coherence tomography (OCT. Here, we illustrate several methods used clinically by reviewing the literature.

  2. Residual Stress in Wheels: Comparison of Neutron Diffraction and Ultrasonic Methods, with Trends in RCF

    OpenAIRE

    Molyneux-Berry, Paul; Bevan, Adam; Zhang, S. Y; Kabra, S

    2014-01-01

    The critical damage mechanism on many GB passenger train wheels is Rolling Contact Fatigue (RCF) cracking in the rim. Evidence from field observations suggests that RCF damage occurs much more quickly as the wheelsets near the end of their life. Wheel manufacturing processes induce a compressive hoop stress in the wheel rim; variations in residual stress through the life of a wheel may influence the observed RCF damage rates.\\ud This paper describes experiments to measure residual stresses in...

  3. Field kit and method for testing for the presence of gunshot residue

    Energy Technology Data Exchange (ETDEWEB)

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  4. Characterization and monitoring of landslides using seismological methods

    Science.gov (United States)

    Bievre, G.; Jongmans, D.; Baillet, L.

    2017-12-01

    Landslides are worlwide-spread natural hazards which affect a various range of lithologies, such as natural and engineered soils, soft rocks and compact rocks. Their characterization and monitoring is a key parameter to evaluate their volume and also their evolution with time. Geophysical methods provide an indirect way to characterize and monitor these highly heterogeneous structures. The most commonly measured geophysical parameters are the electrical resistivity (ρ) and P-waves velocity (Vp). However, water tables are often encountered within landslides and hide the relevant informations to be measured. On the contrary, shear waves are very poorly affected by the presence of water. However, S-waves velocity (Vs) have been little used to study landslides compared to ρ and Vp, most probably because of the difficulty to generate energetic waves. Since a very few decades however, it is possible to efficiently measure Vs from surface waves and not only from body waves. These can be measured both actively (e.g. MASW) and passively (ambient noise). Surface waves allow to retrieve vertical Vs profiles and to derive both lithological and geotechnical (shear surfaces) layers. In soft rocks and soils, surface waves offer a way to monitor very slight but significant Vs changes within landslides. These changes can be correlated to environmental (rainfall, temperature) and to slip rate variations. More interesting, significant Vs decrease were experimentally observed several days (up to 10 days) prior to failure on several clayey landslides. In the same way, the monitoring of the spectral content of surface waves in stiff rocks showed variations related to environmental changes but also to failure. The aim of this communication is to expose results obtained from surface waves measurements and monitoring in the field over the past decade to study landslides. These results were calibrated by laboratory measurements and/or numerical simulation. They show that surface waves and

  5. A simple measurement of the Ni-63 diffusion profiles by residual activity method using a liquid scintillation counter

    Czech Academy of Sciences Publication Activity Database

    Rothová, Věra

    2013-01-01

    Roč. 729, NOV (2013), s. 702-706 ISSN 0168-9002 Institutional support: RVO:68081723 Keywords : Nickel-63 * Low-energy β-emitter * Solid scintillation counting * Diffusion * Gruzin′s residual activity method Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.316, year: 2013

  6. Investigating the Composite Step Biconjugate A-Orthogonal Residual Method for Non-Hermitian Dense Linear Systems in Electromagnetics

    NARCIS (Netherlands)

    Jing, Yan-Fei; Huang, Ting-Zhu; Carpentieri, Bruno; Duan, Yong

    An interesting stabilizing variant of the biconjugate A-orthogonal residual (BiCOR) method is investigated for solving dense complex non-Hermitian systems of linear equations arising from the Galerlcin discretization of surface integral equations in electromagnetics. The novel variant is naturally

  7. Review on Sources and Handling Method of Pesticide Residues in Animal Products

    Directory of Open Access Journals (Sweden)

    Indraningsih

    2006-06-01

    Full Text Available Field studies and literature search showed that some pesticide residues either organochlorines (OC or organophosphates (OP were detected in animal products (meat and milk . Pesticide residues in meat collected from West Java were detected at the level of 0 .8 ppb lindane and 62 ppb diazinon . While in meat from Lampung was detected at the level of 7 ppb lindane . 2 .7 heptachlor, 0 .8 endosulfan and 0 .5 ppb aldrin . Furthermore, pesticide residues were also detected in the milk collected from West, Central and East Java . The levels of lindane were 2,3 ; 15,9 ; 0,2 ppb ; heptachlor 8 ; 0 .4 and 0,05 ppb; diazinon 8 ; 0 and 1,8 ppb; CPM 0,4 ; 0,8 and 0 ppb ; endosulfan 0,1 ; 0,04 and 0,05 ppb for West, Central and East Java, respectively . The source of pesticide contamination in animal products is generally originated from feed materials, fodders . contaminated soils and water around the farm areas . Minimalization approach of pesticide residues in animal products could be conducted integratedly, such as through chemical process, biodegradation using microorganisms . Organic farming system is recognised as an alternative that may be applied to minimise contamination on agricultural land, eventually reducing pesticide residues in the agricultural products . Feeding with organic agricultural by-products with low pesticide residues appears to reduce pesticide residues in animal products . In order to eliminate pesticide contamination in soil, it has to be conducted progressively by implementing sustainable organic farming .

  8. Influence of digestion methods on the recovery of Iron, Zinc, Nickel, Chromium, Cadmium and Lead contents in 11 organic residues

    Directory of Open Access Journals (Sweden)

    Thalita Fernanda Abbruzzini

    2014-02-01

    Full Text Available There are currently many devices and techniques to quantify trace elements (TEs in various matrices, but their efficacy is dependent on the digestion methods (DMs employed in the opening of such matrices which, although "organic", present inorganic components which are difficult to solubilize. This study was carried out to evaluate the recovery of Fe, Zn, Cr, Ni, Cd and Pb contents in samples of composts and cattle, horse, chicken, quail, and swine manures, as well as in sewage sludges and peat. The DMs employed were acid digestion in microwaves with HNO3 (EPA 3051A; nitric-perchloric digestion with HNO3 + HClO4 in a digestion block (NP; dry ashing in a muffle furnace and solubilization of residual ash in nitric acid (MDA; digestion by using aqua regia solution (HCl:HNO3 in the digestion block (AR; and acid digestion with HCl and HNO3 + H2O2 (EPA 3050. The dry ashing method led to the greatest recovery of Cd in organic residues, but the EPA 3050 protocol can be an alternative method for the same purpose. The dry ashing should not be employed to determine the concentration of Cr, Fe, Ni, Pb and Zn in the residues. Higher Cr and Fe contents are recovered when NP and EPA 3050 are employed in the opening of organic matrices. For most of the residues analyzed, AR is the most effective method for recovering Ni. Microwave-assisted digestion methods (EPA3051 and 3050 led to the highest recovery of Pb. The choice of the DM that provides maximum recovery of Zn depends on the organic residue and trace element analyzed.

  9. Evaluation of residual stress distribution of butt-weld pipe and redistribution behavior with crack extension using neutron diffraction method

    International Nuclear Information System (INIS)

    Okido, Shinobu; Hayashi, Makoto; Minakawa, Nobuaki; Morii, Yukio; Ando, Kotoji

    2005-01-01

    Residual stress is known to be redistributed as a result of crack extension. The neutron diffraction method was used to evaluate this residual stress redistribution, using a specimen consisting of a butt-weld-jointed pipe made of type-304 austenitic stainless steel (inner diameter φ=97.1 mm, thickness t=8.9mm). Half-elliptical cracks were introduced by an electrical discharge machining at the inner surface of a heat-affected zone. The ratios of a/t, for crack depth a and specimen thickness t, were 0.25 and 0.5, with aspect ratios a/c, for crack half-length c, of 0.1 and 0.5 Comparing the residual stress distribution before and after the crack introduction showed that although the residual stress distribution along the line of the ligament at the deepest point of the crack changed slightly in front of the crack tip, it did not change throughout the ligament. This result shows that residual stress redistributes through-out in the whole crack tip region, including the width of the crack. (author)

  10. Diffraction grating strain gauge method: error analysis and its application for the residual stress measurement in thermal barrier coatings

    Science.gov (United States)

    Yin, Yuanjie; Fan, Bozhao; He, Wei; Dai, Xianglu; Guo, Baoqiao; Xie, Huimin

    2018-03-01

    Diffraction grating strain gauge (DGSG) is an optical strain measurement method. Based on this method, a six-spot diffraction grating strain gauge (S-DGSG) system has been developed with the advantages of high and adjustable sensitivity, compact structure, and non-contact measurement. In this study, this system is applied for the residual stress measurement in thermal barrier coatings (TBCs) combining the hole-drilling method. During the experiment, the specimen’s location is supposed to be reset accurately before and after the hole-drilling, however, it is found that the rigid body displacements from the resetting process could seriously influence the measurement accuracy. In order to understand and eliminate the effects from the rigid body displacements, such as the three-dimensional (3D) rotations and the out-of-plane displacement of the grating, the measurement error of this system is systematically analyzed, and an optimized method is proposed. Moreover, a numerical experiment and a verified tensile test are conducted, and the results verify the applicability of this optimized method successfully. Finally, combining this optimized method, a residual stress measurement experiment is conducted, and the results show that this method can be applied to measure the residual stress in TBCs.

  11. Validation of a GC-MS method for the estimation of dithiocarbamate fungicide residues and safety evaluation of mancozeb in fruits and vegetables.

    Science.gov (United States)

    Mujawar, Sumaiyya; Utture, Sagar C; Fonseca, Eddie; Matarrita, Jessie; Banerjee, Kaushik

    2014-05-01

    A sensitive and rugged residue analysis method was validated for the estimation of dithiocarbamate fungicides in a variety of fruit and vegetable matrices. The sample preparation method involved reaction of dithiocarbamates with Tin(II) chloride in aqueous HCl. The CS2 produced was absorbed into an isooctane layer and estimated by GC-MS selected ion monitoring. Limit of quantification (LOQ) was ⩽40μgkg(-1) for grape, green chilli, tomato, potato, brinjal, pineapple and chayote and the recoveries were within 75-104% (RSD<15% at LOQ). The method could be satisfactorily applied for analysis of real world samples. Dissipation of mancozeb, the most-used dithiocarbamate fungicide, in field followed first+first order kinetics with pre-harvest intervals of 2 and 4days in brinjal, 7 and 10days in grapes and 0day in chilli at single and double dose of agricultural applications. Cooking practices were effective for removal of mancozeb residues from vegetables. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Analysis of residual stresses on the transverse beam of a casting stand by means of drilling method

    Directory of Open Access Journals (Sweden)

    P. Frankovský

    2014-10-01

    Full Text Available The presented paper demonstrates the application of drilling method in the analysis of residual stresses on the transverse beam of a casting stand. In the initial stage of the analysis the determination of strains was done for individual steps of drilling in the area which was determined by means of numerical analysis. The drilling was carried out gradually by 0,5 mm up to the depth of 5 mm, while the diameter of the drilled hole was 3,2 mm. During the analysis we used the drilling device RS-200, strain indicator P3 and SGD 1-RY21-3/120. The paper presents the development of residual stresses throughout the depth of the drilled hole which were determined according to standard ASTM E837-01, by means of integral method, power series method and by means of Power Series method.

  13. Radiographic apparatus and method for monitoring film exposure time

    International Nuclear Information System (INIS)

    Vatne, R.S.; Woodmansee, W.E.

    1981-01-01

    In connection with radiographic inspection of structural and industrial materials, method and apparatus are disclosed for automatically determining and displaying the time required to expose a radiographic film positioned to receive radiation passed by a test specimen, so that the finished film is exposed to an optimum blackening (density) for maximum film contrast. A plot is made of the variations in a total exposure parameter (representing the product of detected radiation rate and time needed to cause optimum film blackening) as a function of the voltage level applied to an X-ray tube. An electronic function generator storing the shape of this plot is incorporated into an exposure monitoring apparatus, such that for a selected tube voltage setting, the function generator produces an electrical analog signal of the corresponding exposure parameter. During the exposure, another signal is produced representing the rate of radiation as monitored by a diode detector positioned so as to receive the same radiation that is incident on the film. The signal representing the detected radiation rate is divided, by an electrical divider circuit into the signal representing total exposure, and the resulting quotient is an electrical signal representing the required exposure time. (author)

  14. Monitoring of radioiodine and methods for rapid measurement, 2

    International Nuclear Information System (INIS)

    Kamada, Hiroshi

    1979-01-01

    Milk is selected as an indicator or critical food in the environmental monitoring samples, and radioactive iodine as a specific critical radionuclide. Rapid determination of Iodine-131 in the milk has been developed as a standard procedure for the network of environmental radioactivity monitoring in a state of emergency. Outline of the procedure is gamma-ray spectrometry using a heavily shielded 3''diameter x 3'' sodium iodide (thallium-activated) crystal as a detector, 2 liter of Marinelli Beaker for a raw milk and a multi channel pulse height analyzer for quantitative analysis of gamma spectra through the utilization of simultaneous equations. The analysis is what we call ''Milk Matrix Method'' introducing calibration data from the standard samples of Iodine-131, Cesium-137 and Potassium-40. They were selected experimentally, and counting data from the sample were taken into the elements of matrix of set up three simultaneous equations. Most recently detected concentration of Iodine-131 in milk was 81 pCi per liter in 20 May 1978, originated from the nuclear explosion test carried out by the People's Republic of China in 15 May 1978. (author)

  15. Time-Frequency Methods for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Alexander L. Pyayt

    2014-03-01

    Full Text Available Detection of early warning signals for the imminent failure of large and complex engineered structures is a daunting challenge with many open research questions. In this paper we report on novel ways to perform Structural Health Monitoring (SHM of flood protection systems (levees, earthen dikes and concrete dams using sensor data. We present a robust data-driven anomaly detection method that combines time-frequency feature extraction, using wavelet analysis and phase shift, with one-sided classification techniques to identify the onset of failure anomalies in real-time sensor measurements. The methodology has been successfully tested at three operational levees. We detected a dam leakage in the retaining dam (Germany and “strange” behaviour of sensors installed in a Boston levee (UK and a Rhine levee (Germany.

  16. Evaluation of chloramphenicol residues in poultry meat using ELISA method in Isfahan

    Directory of Open Access Journals (Sweden)

    E Rahimi

    2008-11-01

    Full Text Available Chloramphenicol is classified as a broad spectrum veterinary drugs used to treat pulmonary infections in the poultry industry. Even relatively low levels of chloramphenicol residues may give rice to an irreversible type of bone marrow depression leading eventually to anaplastic anemia. This study was conducted with the aim of chicken meat. Chloramphenicol concentraction was measured by enzyme (ELISA in 140 chicken meat samples (thigh muscles presented to the consumption market of isfahan city. In 25 of the 140 evaluated samples (17.9%, presence of chloramephnicol residues was detected in concentrations rouging form 14 to 311 ng/kg with a mean ±standard deviation of 97.9 ±17.7 ng/kg. the results of chloramphenicol residues were low in the samples but this drug is still being used in the poultry industry and this can be a risk to public health.

  17. Evaluation of the antibacterial residue surveillance programme in Danish pigs using Bayesian methods

    DEFF Research Database (Denmark)

    Freitas de Matos Baptista, Filipa; Alban, L.; Olsen, A. M.

    2012-01-01

    the impact of a potential risk-based sampling approach to the residue surveillance programme in Danish slaughter pigs. Danish surveillance data from 2005 to 2009 and limited knowledge about true prevalence and test sensitivity and specificity were included in the model. According to the model, the true...... classes used in Danish pigs. If high-risk slaughter pigs could be identified by taking into account antibacterial use or meat inspection risk factors, a potential risk-based sampling approach to antibacterial residue surveillance in slaughter pigs would allow reducing the sample size substantially, while...... antibacterial residue prevalence in Danish pigs is very low in both sows (~0.20%) and slaughter pigs (~0.01%). Despite data constraints, the results suggest that the current screening test used in Denmark presents high sensitivity (85-99%) and very high specificity (>99%) for the most relevant antibacterial...

  18. Identification and discrimination of herbicide residues using a conducting polymer electronic nose

    Science.gov (United States)

    Alphus Dan Wilson

    2016-01-01

    The identification of herbicide residues on crop foliage is necessary to make crop-management decisions for weed pest control and to monitor pesticide residue levels on food crops. Electronic-nose (e-nose) methods were tested as a cheaper, alternative means of discriminating between herbicide residue types (compared with conventional chromatography methods), by...

  19. Residual Stress Distribution In Heat Affected Zone Of Welded Steel By Means Of Neutron Diffraction Method

    International Nuclear Information System (INIS)

    Fajar, Andika; Prasuad; Gunawan; Muslich, M. Rifai

    1996-01-01

    Three dimensional residual stress distribution in the heat affected zone of 10 mm thick welded steel by means of neutron diffraction technique has been measured. The results showed that the residual stress was distributed near the welded metal, namely within about 46,25 mm. The major tensile stresses occurred in the X-direction, and they attained a level greater than 2000 MPa through the position far away fram the weld. The tensile stresses in the Y and Z- directions lied between 500 and 1500 MPa, The results also suggest that the stress in the surface was greater than that in the middle of the sample

  20. New grower-friendly methods for plant pathogen monitoring.

    Science.gov (United States)

    De Boer, Solke H; López, María M

    2012-01-01

    Accurate plant disease diagnoses and rapid detection and identification of plant pathogens are of utmost importance for controlling plant diseases and mitigating the economic losses they incur. Technological advances have increasingly simplified the tools available for the identification of pathogens to the extent that, in some cases, this can be done directly by growers and producers themselves. Commercially available immunoprinting kits and lateral flow devices (LFDs) for detection of selected plant pathogens are among the first tools of what can be considered grower-friendly pathogen monitoring methods. Research efforts, spurned on by point-of-care needs in the medical field, are paving the way for the further development of on-the-spot diagnostics and multiplex technologies in plant pathology. Grower-friendly methods need to be practical, robust, readily available, and cost-effective. Such methods are not restricted to on-the-spot testing but extend to laboratory services, which are sometimes more practicable for growers, extension agents, regulators, and other users of diagnostic tests.

  1. HemeBIND: a novel method for heme binding residue prediction by combining structural and sequence information

    Directory of Open Access Journals (Sweden)

    Hu Jianjun

    2011-05-01

    Full Text Available Abstract Background Accurate prediction of binding residues involved in the interactions between proteins and small ligands is one of the major challenges in structural bioinformatics. Heme is an essential and commonly used ligand that plays critical roles in electron transfer, catalysis, signal transduction and gene expression. Although much effort has been devoted to the development of various generic algorithms for ligand binding site prediction over the last decade, no algorithm has been specifically designed to complement experimental techniques for identification of heme binding residues. Consequently, an urgent need is to develop a computational method for recognizing these important residues. Results Here we introduced an efficient algorithm HemeBIND for predicting heme binding residues by integrating structural and sequence information. We systematically investigated the characteristics of binding interfaces based on a non-redundant dataset of heme-protein complexes. It was found that several sequence and structural attributes such as evolutionary conservation, solvent accessibility, depth and protrusion clearly illustrate the differences between heme binding and non-binding residues. These features can then be separately used or combined to build the structure-based classifiers using support vector machine (SVM. The results showed that the information contained in these features is largely complementary and their combination achieved the best performance. To further improve the performance, an attempt has been made to develop a post-processing procedure to reduce the number of false positives. In addition, we built a sequence-based classifier based on SVM and sequence profile as an alternative when only sequence information can be used. Finally, we employed a voting method to combine the outputs of structure-based and sequence-based classifiers, which demonstrated remarkably better performance than the individual classifier alone

  2. Characterization of micro-scale residual stress around thermal grown oxide using micro-slotting method and geometric phase analysis

    Science.gov (United States)

    Zhang, Q.; Xie, H.; Liu, Z.; Dai, X.

    2018-03-01

    Characterization of residual stress around thermal grown oxide (TGO) is important for understanding the spallation failure of thermal barrier coatings (TBCs). Cr3+ photoluminescence piezo-spectroscopy (CPLPS) is a nondestructive method for measuring the in-plane residual stress in the TGO layer. However, using CPLPS it is hard to evaluate the out-of-plane residual stress around TGO. Here, we adopted the micro-slotting method combined with geometric phase analysis (GPA) for measuring the in-plane and out-of-plane stresses around TGO, with measured areas of 6  ×  4 µm2. In the experiment, a grating and a slot were milled on the specimen surface using focused ion beam, and GPA was applied to analyze the grating structure before and after the slot milling for calculating the released displacement field. Then finite element analysis was used to infer the residual stress in the direction vertical to the micro-slot. Two experiments were performed on the in-service TBC specimen. The first experiment presented the in-plane compression in the TGO, while the second experiment presented the out-of-plane tension at the crest of the TGO/BC interface, thus validating the theoretical analysis.

  3. Improving Neuromuscular Monitoring and Reducing Residual Neuromuscular Blockade With E-Learning: Protocol for the Multicenter Interrupted Time Series INVERT Study.

    Science.gov (United States)

    Thomsen, Jakob Louis Demant; Mathiesen, Ole; Hägi-Pedersen, Daniel; Skovgaard, Lene Theil; Østergaard, Doris; Engbaek, Jens; Gätke, Mona Ring

    2017-10-06

    Muscle relaxants facilitate endotracheal intubation under general anesthesia and improve surgical conditions. Residual neuromuscular blockade occurs when the patient is still partially paralyzed when awakened after surgery. The condition is associated with subjective discomfort and an increased risk of respiratory complications. Use of an objective neuromuscular monitoring device may prevent residual block. Despite this, many anesthetists refrain from using the device. Efforts to increase the use of objective monitoring are time consuming and require the presence of expert personnel. A neuromuscular monitoring e-learning module might support consistent use of neuromuscular monitoring devices. The aim of the study is to assess the effect of a neuromuscular monitoring e-learning module on anesthesia staff's use of objective neuromuscular monitoring and the incidence of residual neuromuscular blockade in surgical patients at 6 Danish teaching hospitals. In this interrupted time series study, we are collecting data repeatedly, in consecutive 3-week periods, before and after the intervention, and we will analyze the effect using segmented regression analysis. Anesthesia departments in the Zealand Region of Denmark are included, and data from all patients receiving a muscle relaxant are collected from the anesthesia information management system MetaVision. We will assess the effect of the module on all levels of potential effect: staff's knowledge and skills, patient care practice, and patient outcomes. The primary outcome is use of neuromuscular monitoring in patients according to the type of muscle relaxant received. Secondary outcomes include last recorded train-of-four value, administration of reversal agents, and time to discharge from the postanesthesia care unit as well as a multiple-choice test to assess knowledge. The e-learning module was developed based on a needs assessment process, including focus group interviews, surveys, and expert opinions. The e

  4. REST: a computer system for estimating logging residue by using the line-intersect method

    Science.gov (United States)

    A. Jeff Martin

    1975-01-01

    A computer program was designed to accept logging-residue measurements obtained by line-intersect sampling and transform them into summaries useful for the land manager. The features of the program, along with inputs and outputs, are briefly described, with a note on machine compatibility.

  5. An EThcD-Based Method for Discrimination of Leucine and Isoleucine Residues in Tryptic Peptides

    Science.gov (United States)

    Zhokhov, Sergey S.; Kovalyov, Sergey V.; Samgina, Tatiana Yu.; Lebedev, Albert T.

    2017-08-01

    An EThcD-based approach for the reliable discrimination of isomeric leucine and isoleucine residues in peptide de novo sequencing procedure has been proposed. A multistage fragmentation of peptide ions was performed with Orbitrap Elite mass spectrometer in electrospray ionization mode. At the first stage, z-ions were produced by ETD or ETcaD fragmentation of doubly or triply charged peptide precursor ions. These primary ions were further fragmented by HCD with broad-band ion isolation, and the resulting w-ions showed different mass for leucine and isoleucine residues. The procedure did not require manual isolation of specific z-ions prior to HCD stage. Forty-three tryptic peptides (3 to 27 residues) obtained by trypsinolysis of human serum albumin (HSA) and gp188 protein were analyzed. To demonstrate a proper solution for radical site migration problem, three non-tryptic peptides were also analyzed. A total of 93 leucine and isoleucine residues were considered and 83 of them were correctly identified. The developed approach can be a reasonable substitution for additional Edman degradation procedure, which is still used in peptide sequencing for leucine and isoleucine discrimination.

  6. METHODOLOGY OF ESTABLISHING RESIDUAL LIFETIME OF LIFTING INSTALATION BY NON-DESTRUCTIVE METHODS

    Directory of Open Access Journals (Sweden)

    Florin VÎLCEANU

    2013-05-01

    Full Text Available In this paper are presented first the theoretical ground for metal fatigue and then analysissteps to be taken in order to establishing the residual lifetime of a lifting crane by non-destructivemethods, while observing all the current regulations

  7. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    Science.gov (United States)

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  8. Methods of iodine-129 analysis for environmental monitoring

    International Nuclear Information System (INIS)

    Yamato, Aiji; Miyagawa, Naoto; Nomura, Tamotsu; Kinoshita, Mutsumi

    1976-01-01

    Some methods for the analysis of I-129 in the environment are described. Iodide ion in seawater is coprecipitated with chloride ion by silver citrate powder, and that in seaweeds and in sediment is sublimated by heating at about 900 0 C in O 2 atmosphere, and then the iodine is trapped in cooled NaOH and NaHSO 3 mixed solution. The trapped iodine is precipitated with AgNO 3 solution for γ-/X-ray spectrometry (detection limit asymptotically equals 30 pCi), or extracted into toluene scintillater solution for liquid scintillation counting. The decomposition of AgI is necessary for low level I-129 measurement; The AgI was transfered in a flask, added with 2N H 2 SO 4 and Zn sand, and decomposed by stirring for 2 hr. Filtered the solution, added 0.5 g of NaNO 2 and toluene scintillater to extract the iodine then added 1 ml of 2-methyl 1-butene to decolorize, the solution is measured by a liquid scintillation counter (detection limit asymptotically equals 1 pCi). This method can be applied for monitoring of low level radioactive water waste. (auth.)

  9. Monitoring of N-methyl carbamate pesticide residues in water using hollow fibre supported liquid membrane and solid phase extraction

    Science.gov (United States)

    Msagati, Titus A. M.; Mamba, Bhekie B.

    The aim of this work was to develop a method for the determination of N-methyl carbamates in water involving hollow fibre supported liquid membrane (HFSLM) and solid phase extraction (SPE) as sample preparation methods. Four N-methyl carbamate pesticides, aldicarb, carbaryl, carbofuran and methiocarb sulfoxide, were simultaneously extracted and analysed by a liquid chromatograph with a diode array detector (LC-UV/DAD) and a liquid chromatograph coupled to a ion trap quadrupole mass spectrometer (LC-ESI-MS). The high performance liquid chromatography (HPLC) separation of carabamate extracts was performed on a C18 column with water-acetonitrile as the mobile phase. The mass spectrometry analyses were carried out in the positive mode, operating under both the selected ion monitoring (SIM) and full scan modes. The solid phase recoveries of the extracts ranged between 8% and 98%, with aldicarb having the highest recoveries, followed by carbaryl, carbofuran and methiocarb had the lowest recovery. The HFSLM recovery ranged between 8% and 58% and the order of recovery was similar to the SPE trend. Factors controlling the efficiency of the HFSLM extraction such as sample pH, stripping phase pH, enrichment time, stirring speed as well as organic solvent used for entrapment of analytes, were optimised to achieve the highest enrichment factors.

  10. An Innovative Rapid Method for Analysis of 10 Organophosphorus Pesticide Residues in Wheat by HS-SPME-GC-FPD/MSD.

    Science.gov (United States)

    Du, Xin; Ren, YongLin; Beckett, Stephen J

    2016-01-01

    The rapid detection of pesticide residues in wheat has become a top food security priority. A solvent-free headspace solid-phase microextraction (HS-SPME) has been evaluated for rapid screening of organophosphorus pesticide (OPP) residues in wheat with high sensitivity. Individual wheat samples (1.7 g), spiked with 10 OPPs, were placed in a 4 mL sealed amber glass vial and heated at 60°C for 45 min. During this time, the OPP residues were extracted with a 50 μm/30 μm divinylbenzene (DVB)/carboxen (CAR)/plasma desorption mass spectroscopy polydimethylsiloxane (PDMS) fiber from the headspace above the sample. The fiber was then removed and injected into the GC injection port at 250°C for desorption of the extracted chemicals. The multiple residues were identified by a GC mass spectrometer detector (GC-MSD) and quantified with a GC flame photometric detector (GC-FPD). Seven spiked levels of 10 OPPs on wheat were analyzed. The GC responses for a 50 μm/30 μm DVB/CAR/PDMS fiber increased with increasing spiking levels, yielding significant (R(2) > 0.98) linear regressions. The lowest LODs of the multiple pesticide standards were evaluated under the conditions of the validation study in a range of levels from 0 (control) to 100 ng of pesticide residue per g of wheat that separated on a low-polar GC capillary column (Agilent DB-35UI). The results of the HS-SPME method were compared with the QuEChERS AOAC 2007.01 method and they showed several advantages over the latter. These included improved sensitivity, selectivity, and simplicity.

  11. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  12. Two-Dimensional UV Absorption Correlation Spectroscopy as a Method for the Detection of Thiamethoxam Residue in Tea

    Science.gov (United States)

    Zhang, J.; Zhao, Zh.; Wang, L.; Zhu, X.; Shen, L.; Yu, Y.

    2015-05-01

    Two-dimensional correlation spectroscopy (2D-COS) combined with UV absorption spectroscopy was evaluated as a technique for the identification of spectral regions associated with the residues of thiamethoxam in tea. There is only one absorption peak at 275 nm in the absorption spectrum of a mixture of thiamethoxam and tea, which is the absorption peak of tea. Based on 2D-COS, the absorption peak of thiamethoxam at 250 nm is extracted from the UV spectra of the mixture. To determine the residue of thiamethoxam in tea, 250 nm is selected as the measured wavelength, at which the fitting result is as follows: the residual sum of squares is 0.01375, standard deviation R2 is 0.99068, and F value is 426. Statistical analysis shows that there is a significant linear relationship between the concentration of thiamethoxam in tea and the absorbance at 250 nm in the UV spectra of the mixture. Moreover, the average prediction error is 0.0033 and the prediction variance is 0.1654, indicating good predictive result. Thus, the UV absorption spectrum can be used as a measurement method for rapid detection of thiamethoxam residues in tea.

  13. Method for improve x-ray diffraction determinations of residual stress in nickel-base alloys

    Science.gov (United States)

    Berman, Robert M.; Cohen, Isadore

    1990-01-01

    A process for improving the technique of measuring residual stress by x-ray diffraction in pieces of nickel-base alloys which comprises covering part of a predetermined area of the surface of a nickel-base alloy with a dispersion, exposing the covered and uncovered portions of the surface of the alloy to x-rays by way of an x-ray diffractometry apparatus, making x-ray diffraction determinations of the exposed surface, and measuring the residual stress in the alloy based on these determinations. The dispersion is opaque to x-rays and serves a dual purpose since it masks off unsatisfactory signals such that only a small portion of the surface is measured, and it supplies an internal standard by providing diffractogram peaks comparable to the peaks of the nickel alloy so that the alloy peaks can be very accurately located regardless of any sources of error external to the sample.

  14. Method for improving x-ray diffraction determinations of residual stress in nickel-base alloys

    Science.gov (United States)

    Berman, R.M.; Cohen, I.

    1988-04-26

    A process for improving the technique of measuring residual stress by x-ray diffraction in pieces of nickel-base alloys is discussed. Part of a predetermined area of the surface of a nickel-base alloy is covered with a dispersion. This exposes the covered and uncovered portions of the surface of the alloy to x-rays by way of an x-ray diffractometry apparatus, making x-ray diffraction determinations of the exposed surface, and measuring the residual stress in the alloy based on these determinations. The dispersion is opaque to x-rays and serves a dual purpose, since it masks off unsatisfactory signals such that only a small portion of the surface is measured, and it supplies an internal standard by providing diffractogram peaks comparable to the peaks of the nickel alloy so that the alloy peaks can be very accurately located regardless of any sources of error external to the sample. 2 figs.

  15. STAGS Developments for Residual Strength Analysis Methods for Metallic Fuselage Structures

    Science.gov (United States)

    Young, Richard D.; Rose, Cheryl A.

    2014-01-01

    A summary of advances in the Structural Analysis of General Shells (STAGS) finite element code for the residual strength analysis of metallic fuselage structures, that were realized through collaboration between the structures group at NASA Langley, and Dr. Charles Rankin is presented. The majority of the advancements described were made in the 1990's under the NASA Airframe Structural Integrity Program (NASIP). Example results from studies that were conducted using the STAGS code to develop improved understanding of the nonlinear response of cracked fuselage structures subjected to combined loads are presented. An integrated residual strength analysis methodology for metallic structure that models crack growth to predict the effect of cracks on structural integrity is demonstrated

  16. Successful Therapy Reduction and Intensification for Childhood Acute Lymphoblastic Leukemia Based on Minimal Residual Disease Monitoring : Study ALL10 From the Dutch Childhood Oncology Group

    NARCIS (Netherlands)

    Pieters, Rob; de Groot-Kruseman, Hester; Van der Velden, Vincent; Fiocco, Marta; van den Berg, Henk; Bont, de Evelien; Egeler, R. Maarten; Hoogerbrugge, Peter; Kaspers, Gertjan; Van der Schoot, Ellen; De Haas, Valerie; Van Dongen, Jacques

    2016-01-01

    Purpose Outcome of childhood acute lymphoblastic leukemia (ALL) improved greatly by intensifying chemotherapy for all patients. Minimal residual disease (MRD) levels during the first months predict outcome and may select patients for therapy reduction or intensification. Methods Patients 1 to 18

  17. Acoustic transmission in non-uniform ducts with mean flow. I - The method of weighted residuals. II - The finite element method

    Science.gov (United States)

    Eversman, W.; Astley, R. J.

    1981-01-01

    The problem of acoustic transmission through nonuniform ducts containing a high-speed subsonic flow is studied by means of the method of weighted residuals in the form of a modified Galerkin method and a Galerkin formulation of the finite element method. The method of weighted residuals is shown to employ the basis functions generated from eigenvalue calculations for the case of no flow, and is verified by comparison with exact eigenvalue calculations in the uniform duct case and numerical solutions of the one-dimensional form of the equations in the nonuniform duct case. The finite element scheme based on both the Galerkin method and the residual least squares method and employing eight-noded isoparametric elements is presented and used to investigate multimodal propagation by the coupling of the solution in the duct nonuniform section to modal expansions in uniform sections. Comparison of the results of the two methods reveals them to be in substantial agreement, and predicts the importance of multimodal interactions at high Mach numbers.

  18. Bridge Scour Monitoring Methods at Three Sites in Wisconsin

    National Research Council Canada - National Science Library

    Walker, John F; Hughes, Peter E

    2005-01-01

    ...) automated monitoring, using moderately sophisticated electronic equipment. The results from all three sites demonstrate that both techniques can produce reasonable measurements of streambed elevation...

  19. Methods and advantages of intercomparisons of TLDs for environmental monitoring

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Klemic, G.

    1997-01-01

    One of the most difficult tasks facing the international community is the monitoring of environmental radiation for potential increases due to facility accidents or weapons activity. Monitoring networks have been established to provide a record of natural background radiation as well as measure any radiation releases from a facility. Thermoluminescent dosimeters (TLDs) are an important element of such networks and are the most widely used passive detector for environmental monitoring. In order to reach a high international standard in the application of TLDs in routine environmental monitoring, there is a need for a intercomparisons. (authors)

  20. Multi-country assessment of residual bio-efficacy of insecticides used for indoor residual spraying in malaria control on different surface types: results from program monitoring in 17 PMI/USAID-supported IRS countries.

    Science.gov (United States)

    Dengela, Dereje; Seyoum, Aklilu; Lucas, Bradford; Johns, Benjamin; George, Kristen; Belemvire, Allison; Caranci, Angela; Norris, Laura C; Fornadel, Christen M

    2018-01-30

    Indoor residual spraying (IRS) is the application of insecticide to the interior walls of household structures that often serve as resting sites for mosquito vectors of malaria. Human exposure to malaria vectors is reduced when IRS involves proper application of pre-determined concentrations of the active ingredient specific to the insecticide formulation of choice. The impact of IRS can be affected by the dosage of insecticide, spray coverage, vector behavior, vector susceptibility to insecticides, and the residual efficacy of the insecticide applied. This report compiles data on the residual efficacy of insecticides used in IRS campaigns implemented by the United States President's Malaria Initiative (PMI)/United States Agency for International Development (USAID) in 17 African countries and compares observed length of efficacy to ranges proposed in World Health Organization (WHO) guidelines. Additionally, this study provides initial analysis on variation of mosquito mortality depending on the surface material of sprayed structures, country spray program, year of implementation, source of tested mosquitoes, and type of insecticide. Residual efficacy of the insecticides used for PMI/USAID-supported IRS campaigns was measured in Benin, Burkina Faso, Ethiopia, Ghana, Kenya, Liberia, Madagascar, Malawi, Mali, Mozambique, Nigeria, Rwanda, Senegal, Tanzania, Uganda, Zambia and Zimbabwe. The WHO cone bioassay tests were used to assess the mortality rate of mosquitoes exposed to insecticide-treated mud, wood, cement, and other commonly used housing materials. Baseline tests were performed within weeks of IRS application and follow-up tests were continued until the mortality of exposed mosquitoes dropped below 80% or the program monitoring period ended. Residual efficacy in months was then evaluated with respect to WHO guidelines that provide suggested ranges of residual efficacy for insecticide formulations recommended for use in IRS. Where the data allowed, direct

  1. Neutron-activation method of monitoring of the environment

    International Nuclear Information System (INIS)

    Sattarov, G.S.; Muzafarov, A.M.; Komilov, J.M.; Kadirov, F.; Kist, A.A.

    2004-01-01

    Full text: Estimation of technogenic influences of the industrial enterprises on an environment, in particular, on ground and underground waters, was carried out by the fragmentary analysis of their element structure. In the report application of neutron-activation analysis (NAA) for monitoring an environment is considered. The total contents of elements was determined by NAA method with use of a reactor such as WWR-SM. Values of factors of correlation (K) are calculated with use of the computer, by special algorithm and reception of numerical values between 30 elements in the samples selected by a traditional technique from more than 600 points in area of activity GMZ-2. The developed technique has allowed to reveal elements indicators of technogenic (As, Ag, Sb, W, Au), mixed (Mo, Ba, Hg) and natural (Sc, Fe, Co, Ni, Rb, Cs, REE, Hf, Th, U) origins. Change of the total contents of elements in underground waters which were selected from observant chinks quarterly within three years is investigated. The technique of definition of forms of a presence of elements in underground and the sewage, based on electrodialysis division of ions with use nuclear (on a basis polyethyleneterephtalate film) filters with a diameter of pores of 0,16x0,2 micrometres is developed

  2. Method for monitoring stack gases for uranium activity

    International Nuclear Information System (INIS)

    Beverly, C.R.; Ernstberger, H.G.

    1988-01-01

    A method for sampling stack gases emanating from the purge cascade of a gaseous diffusion cascade system utilized to enrich uranium for determining the presence and extent of uranium in the stack gases in the form of gaseous uranium hexafluoride, is described comprising the steps of removing a side stream of gases from the stack gases, contacting the side stream of the stack gases with a stream of air sufficiently saturated with moisture for reacting with and converting any gaseous uranium hexafluroide contracted thereby in the side stream of stack gases to particulate uranyl fluoride. Thereafter contacting the side stream of stack gases containing the particulate uranyl fluoride with moving filter means for continuously intercepting and conveying the intercepted particulate uranyl fluoride away from the side stream of stack gases, and continually scanning the moving filter means with radiation monitoring means for sensing the presence and extent of particulate uranyl fluoride on the moving filter means which is indicative of the extent of particulate uranyl fluoride in the side stream of stack gases which in turn is indicative of the presence and extent of uranium hexafluoride in the stack gases

  3. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  4. Development and validation of multi-residue and multi-class method for antibacterial substances analysis in non-target feed by liquid chromatography - tandem mass spectrometry.

    Science.gov (United States)

    Patyra, Ewelina; Nebot, Carolina; Gavilán, Rosa Elvira; Cepeda, Alberto; Kwiatek, Krzysztof

    2018-03-01

    A confirmatory HPLC-MS/MS method for the determination of residues of 11 antibacterial substances from different therapeutic class (β-lactams, lincosamides, fluoroquinolones, macrolides, pleuromutilins and sulfonamides) in animal feeds has been developed. The sample preparation is based on extraction with 0.1% formic acid in acetonitrile. Separation of the analytes was performed on biphenyl column with a gradient of 0.1% formic acid in acetonitrile and 0.1% formic acid in Milli-Q water. The developed method was validated following the guidelines included in the European Union Commission Decision 2002/657/EC. Limits of detection ranging from 79.22 to 193.60 µg/kg; instrumental and analytical linearity coefficients were above 0.99 for matrix-match calibration; and relative recoveries ranging from 76.04% to 117.39%. Repeatability of the method was in the range of 2.41-19.76% (CV, %), whereas reproducibility ranged from 6.52 to 28.40% (CV %). The method shown to be efficient and precise for quantification of the 11 antibacterial substances in animal feed. The results demonstrate the feasibility of the method for routine use to monitor these substances in feed. The validated method was successfully applied to eight suspect feed samples collected from the Association of American Feed Control Officials (AFFCO) and feed manufactures from Galicia (Spain) in June and July 2017. Of these 8 non-target feeds, 5 were positive for the presence of tiamulin, tylosin and sulfadiazine.

  5. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Rambaud, Lauriane; Monteau, Fabrice; Deceuninck, Yoann; Bichon, Emmanuelle; Andre, Francois; Le Bizec, Bruno

    2007-01-01

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CCα) for main steroids were in the 0.1-10 μg kg -1 range

  6. Methods to obtain referral criteria in growth monitoring

    NARCIS (Netherlands)

    Van Dommelen, Paula; Van Buuren, Stef

    An important goal of growth monitoring is to identify genetic disorders, diseases or other conditions that manifest themselves through an abnormal growth. The two main conditions that can be detected by height monitoring are Turner's syndrome and growth hormone deficiency. Conditions or risk factors

  7. Apparatus and method for monitoring of gas having stable isotopes

    Science.gov (United States)

    Clegg, Samuel M; Fessenden-Rahn, Julianna E

    2013-03-05

    Gas having stable isotopes is monitored continuously by using a system that sends a modulated laser beam to the gas and collects and transmits the light not absorbed by the gas to a detector. Gas from geological storage, or from the atmosphere can be monitored continuously without collecting samples and transporting them to a lab.

  8. Large-scale monitoring of effects of clothianidin-dressed oilseed rape seeds on pollinating insects in northern Germany: residues of clothianidin in pollen, nectar and honey

    OpenAIRE

    Rolke, Daniel; Persigehl, Markus; Peters, Britta; Sterk, Guido; Blenau, Wolfgang

    2016-01-01

    This study was part of a large-scale monitoring project to assess the possible effects of Elado® (10 g clothianidin & 2 g β-cyfluthrin/kg seed)-dressed oilseed rape seeds on different pollinators in Northern Germany. Firstly, residues of clothianidin and its active metabolites thiazolylnitroguanidine and thiazolylmethylurea were measured in nectar and pollen from Elado®-dressed (test site, T) and undressed (reference site, R) oilseed rape collected by honey bees confined within tunnel tents. ...

  9. From molecules to management: adopting DNA-based methods for monitoring biological invasions in aquatic environments

    Science.gov (United States)

    Recent technological advances have driven rapid development of DNA-based methods designed to facilitate detection and monitoring of invasive species in aquatic environments. These tools promise to significantly alleviate difficulties associated with traditional monitoring approac...

  10. Rapid ion-pair liquid chromatographic method for the determination of fenbendazole marker residue in fermented dairy products.

    Science.gov (United States)

    Vousdouka, Venetia I; Papapanagiotou, Elias P; Angelidis, Apostolos S; Fletouris, Dimitrios J

    2017-04-15

    A simple, rapid and sensitive liquid chromatographic method that allows for the quantitative determination of fenbendazole residues in fermented dairy products is described. Samples were extracted with a mixture of acetonitrile-phosphoric acid and the extracts were defatted with hexane to be further partitioned into ethyl acetate. The organic layer was evaporated to dryness and the residue was reconstituted in mobile phase. Separation of fenbendazole and its sulphoxide, sulphone, and p-hydroxylated metabolites was carried out isocratically with a mobile phase containing both positively and negatively charged pairing ions. Overall recoveries ranged from 79.8 to 88.8%, while precision data, based on within and between days variations, suggested an overall relative standard deviation of 6.3-11.0%. The detection and quantification limits were lower than 9 and 21μg/kg, respectively. The method has been successfully applied to quantitate fenbendazole residues in Feta cheese and yoghurt made from spiked and incurred ovine milk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Method and apparatus for removing an in-core monitor

    International Nuclear Information System (INIS)

    Yoshida, Tomiji; Saito, Takashi; Ishii, Yoshimi; Arikawa, Isamu; Yamagata, Hiroko.

    1976-01-01

    Object: To cut an unremovable in-core monitor in a suitable position by remote control within a reactor and thereafter to remove the in-core monitor. Structure: A cutter body comprises an upper gripping mechanism, a mechanism for upwardly and downwardly moving the upper gripping mechanism, a cutter portion, and a lower gripping mechanism, and when the in-core monitor becomes impossible to be removed from a core, the cutter body is set within a cell of a top guide. First, the in-core monitor can be gripped by the gripping mechanism and then cut by operation of the cutter portion. Next, the lower part of the monitor is gripped by the lower gripping mechanism. Whereafter, the upwardly and downwardly moving mechanism can be operated to remove the head of the in-core monitor from a recess in a top guide. When the cutter body is then removed from the top guide, the in-core monitor is completed to be cut and removed. (Kamimura, M.)

  12. Effects of Adopting Different Kinds of Collecting Method for Years on Film Residual Coefficient and Maize Yields

    OpenAIRE

    TANG Wen-xue; MA Zhong-ming; WEI Tao

    2017-01-01

    Wide usage of mulching technology has increased crop yields, but the large amounts of mulching film residue resulting from widespread use of plastic film in China has brought about a series of pollution hazards. Based on a 4-year (2011-2014) long-term experiment, the effects of different kinds of collecting mothod (zero plastic film residues, conventional plastic film residues, whole plastic film residues remainded) on plastic film residues, residual coefficient and maize yield were explored....

  13. Comparison of methods of zeta potential and residual turbidity of pectin solutions using calcium sulphate/aluminium sulphate as a precipitant

    Directory of Open Access Journals (Sweden)

    Kuljanin Tatjana A.

    2017-01-01

    Full Text Available The affinity of calcium ion binding from CaO used in the most common process of purification of sugar beet juice is relatively low. Therefore, large amounts of this compound are required. This paper presents the theoretical basis of a novel sugar beet juice purification method based on the application of the binary system CaSO4/Al2(SO4 . In order to monitor the process of coagulation and precipitation of pectin in the presence of CaSO4/Al2(SO43, two methods were compared: measurement of the zeta potential and of residual solution turbidity. The zeta potential of pectin solution was determined by electrophoretic method, while the residual turbidity was determined by spectrophotometry. Two model solutions of pectin (0.1 % w/w were investigated. Studies were performed with 10 different concentrations of the binary solution CaSO4/Al2(SO43 (50 - 500 g dm-3. The amount of the precipitant CaSO4/Al2(SO43 (1:1 w/w needed to achieve the minimum solution turbidity and charge neutralization of pectin particles (zero zeta potential were measured and compared. Colloidal destabilization occurred before a complete neutralization of the surface charge of pectin particles (zeta potential ~ 0 mV. Optimal quantities (490 - 705 mg g-1 pectin of the applied binary mixture, were obtained using both methods. This is much lower than the amount of CaO that is commonly used in the conventional process of sugar beet juice purification (about 9 g• g-1 pectin. The use of these precipitants could be important from both economic and environmental point of view. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR 31055

  14. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods

    NARCIS (Netherlands)

    Wentholt, Iris M. E.; Hart, August A.; Hoekstra, Joost B. L.; DeVries, J. Hans

    2008-01-01

    With more and more continuous glucose monitoring devices entering the market, the importance of adequate accuracy assessment grows. This review discusses pros and cons of Regression Analysis and Correlation Coefficient, Relative Difference measures, Bland Altman plot, ISO criteria, combined curve

  15. Gas Chromatographic Method: Tool for Rapid and Sensitive Analysis of Residual Solvents in Amoxicillin and Ampicillin Tablets

    Directory of Open Access Journals (Sweden)

    Sk Manirul Haque

    2015-12-01

    Full Text Available A simple and sensitive static head space gas chromatographic (SH-GC method equipped with FID has been developed and validated for simultaneous determination of residual solvents e.g.,  methanol, dichloromethane and toluene in two therapeutic drugs such as amoxicillin  and ampicillin. The separation was achieved with 30 m long Elite - 5 fused silica capillary column and 0.32 mm inner diameter. The developed SH-GC method offered symmetric peak shape, good resolution and reasonable retention time for all the solvents. Beer’s law was obeyed in the concentration ranges 100 – 1200, 50 – 1000 and 50 – 500 ppm for methanol, dichloromethane and toluene, respectively. The method was validated according to international conference on harmonization (ICH guidelines in terms of specificity, linearity, precision, accuracy, limit of detection, limit of quantitation, robustness and solution stability. The degrees of linearity of the calibration curves, the percent recoveries, relative standard deviation for the method were also determined. All the validation parameters were within the acceptable range. The developed SH-GC method could, therefore, be suitable for simple and rapid detection of trace levels residual solvents in other pharmaceutical products and thereby it could be used for routine analysis in any analytical laboratory.

  16. Monitoring Mining Subsidence Using A Combination of Phase-Stacking and Offset-Tracking Methods

    Directory of Open Access Journals (Sweden)

    Hongdong Fan

    2015-07-01

    Full Text Available An approach to study the mechanism of mining-induced subsidence, using a combination of phase-stacking and sub-pixel offset-tracking methods, is reported. In this method, land subsidence with a small deformation gradient was calculated using time-series differential interferometric synthetic aperture radar (D-InSAR data, whereas areas with greater subsidence were calculated by a sub-pixel offset-tracking method. With this approach, time-series data for mining subsidence were derived in Yulin area using 11 TerraSAR-X (TSX scenes from 13 December 2012 to 2 April 2013. The maximum mining subsidence and velocity values were 4.478 m and 40 mm/day, respectively, which were beyond the monitoring capabilities of D-InSAR and advanced InSAR. The results were compared with the GPS field survey data, and the root mean square errors (RMSE of the results in the strike and dip directions were 0.16 m and 0.11 m, respectively. Four important results were obtained from the time-series subsidence in this mining area: (1 the mining-induced subsidence entered the residual deformation stage within about 44 days; (2 the advance angle of influence changed from 75.6° to 80.7°; (3 the prediction parameters of mining subsidence; (4 three-dimensional deformation. This method could be used to predict the occurrence of mining accidents and to help in the restoration of the ecological environment after mining activities have ended.

  17. Residual deposits (residual soil)

    International Nuclear Information System (INIS)

    Khasanov, A.Kh.

    1988-01-01

    Residual soil deposits is accumulation of new formate ore minerals on the earth surface, arise as a result of chemical decomposition of rocks. As is well known, at the hyper genes zone under the influence of different factors (water, carbonic acid, organic acids, oxygen, microorganism activity) passes chemical weathering of rocks. Residual soil deposits forming depends from complex of geologic and climatic factors and also from composition and physical and chemical properties of initial rocks

  18. Preliminary results for the detection method of perfluoroalkyl substances (PFASs residues in pork

    Directory of Open Access Journals (Sweden)

    Shih-kuo Lin

    2017-05-01

    Full Text Available The perfluoroalkyl substances (PFASs residues, which come from environmental pollution, tend to accumulate in the food chain (EFSA, 2008; Guerranti et al., 2013. 17 chemicals of PFASs family were selected for this study. Fresh pork samples were extracted by Waters® WAX SPE (solid phase extraction cartridges. All extracted samples were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS. The results of calibration curves of each PFAS were good, the R2 values ranging from 0.9901 to 0.9993. The Recoveries were in the range 80%-119%. The protocol of extraction by Waters® WAX SPE cartridge will be applied in future studies.

  19. Development of Analytical Method for Predicting Residual Mechanical Properties of Corroded Steel Plates

    Directory of Open Access Journals (Sweden)

    J. M. R. S. Appuhamy

    2011-01-01

    Full Text Available Bridge infrastructure maintenance and assurance of adequate safety is of paramount importance in transportation engineering and maintenance management industry. Corrosion causes strength deterioration, leading to impairment of its operation and progressive weakening of the structure. Since the actual corroded surfaces are different from each other, only experimental approach is not enough to estimate the remaining strength of corroded members. However, in modern practices, numerical simulation is being used to replace the time-consuming and expensive experimental work and to comprehend on the lack of knowledge on mechanical behavior, stress distribution, ultimate behavior, and so on. This paper presents the nonlinear FEM analyses results of many corroded steel plates and compares them with their respective tensile coupon tests. Further, the feasibility of establishing an accurate analytical methodology to predict the residual strength capacities of a corroded steel member with lesser number of measuring points is also discussed.

  20. Effects of Adopting Different Kinds of Collecting Method for Years on Film Residual Coefficient and Maize Yields

    Directory of Open Access Journals (Sweden)

    TANG Wen-xue

    2017-03-01

    Full Text Available Wide usage of mulching technology has increased crop yields, but the large amounts of mulching film residue resulting from widespread use of plastic film in China has brought about a series of pollution hazards. Based on a 4-year (2011-2014 long-term experiment, the effects of different kinds of collecting mothod (zero plastic film residues, conventional plastic film residues, whole plastic film residues remainded on plastic film residues, residual coefficient and maize yield were explored. Plastic film residues mainly remained in 0~10 cm, 10~20 cm soil layers. In 0~30 cm soil layers, the two types of mulch residues (>25 cm2, 4~25 cm2 under zero plastic film residues treatment were much less than conventional plastic film residues and whole plastic film residues remainded treatments, no significant differences were observed in the mulch residues (2 among 3 treatments. After maize harvest, the amount of plastic film residues under zero plastic film residues, conventional plastic film residues and whole plastic film residues remainded treatments were 52.71, 80.85 kg·hm-2 and 152.65 kg·hm-2, respectively, the residual coefficient for zero plastic film residues, conventional plastic film residues and whole plastic film residues remainded treatments were -9.45%, 8.53% and 54.42%, respectively. The stem diameter, ear length, ear width, ear row number, grain number per row and 100-grain weight of maize decreased with the increase of residual film amount. Compared with the conventional plastic film residues, the mean grain yield of whole plastic film residues remainded treatment decreased by 15.08%, whereas the zero plastic film residues treatment increased by 4.70%. The plastic film residues, residual coefficient and maize yield were comprehensively analyzed, the conventional plastic film residues practice should be adopted currently without appropriate plastic film residues collector. But from the long-term development, we should speed up the

  1. Nutrition-dependent changes of mouse adipose tissue compositions monitored by NMR, MS, and chromatographic methods.

    Science.gov (United States)

    Popkova, Yulia; Meusel, Andrej; Breitfeld, Jana; Schleinitz, Dorit; Hirrlinger, Johannes; Dannenberger, Dirk; Kovacs, Peter; Schiller, Jürgen

    2015-07-01

    Many diseases nowadays are assumed to be genetically determined. Therefore, many knockout mouse models have been established and are widely used. Unfortunately, nutrition (in particular the fat content of food) is often neglected in studies on these disease models. In this study the effects of nutrition on the lipid (triacylglycerol, TAG) compositions of different mouse adipose tissues were investigated. Mice were subjected to different diets [high fat (HF) vs. standard diet (SD)] and different adipose tissue samples (brown, visceral, and subcutaneous fat) were isolated after 12 weeks. Subsequent to lipid extraction, the organic extracts were analyzed by mass spectrometry (MALDI and ESI), high-resolution (1)H and (31)P NMR spectroscopy, high-performance thin-layer chromatography (HPTLC), and gas chromatography (GC). In adipose tissue of mice fed with HF diet, (a) decreased double bond contents and (b) decreased fatty acyl chain lengths of tissue TAGs were observed; this trend could be concomitantly monitored by all methods used. However, the adipose tissue still contained significant amounts of slightly unsaturated fatty acyl residues (18:1). Thus, a certain double bond content seems necessary to maintain the properties of adipose tissues.

  2. Results from the monitoring of pesticide residues in fruit and vegetables on the Danish market 1998-99

    DEFF Research Database (Denmark)

    Andersen, Jens Hinge; Poulsen, Mette Erecius

    2001-01-01

    findings and on food consumption data. Approximately 60% of the samples were selected on the basis of positive findings in samples from the previous 5 years. The remaining samples reflected the pattern of food consumption in Denmark. In addition, a rolling programme is maintained for commodities with a low...... consumption and no detected residues. Within each commodity, the sampling was random. Samples (n = 4150) of mainly fresh, conventionally grown fruit and vegetables were taken throughout the chain of suppliers including foodprocessing companies. Of the samples, 3% were frozen products and 2% were organically...

  3. SequenceCEROSENE: a computational method and web server to visualize spatial residue neighborhoods at the sequence level.

    Science.gov (United States)

    Heinke, Florian; Bittrich, Sebastian; Kaiser, Florian; Labudde, Dirk

    2016-01-01

    To understand the molecular function of biopolymers, studying their structural characteristics is of central importance. Graphics programs are often utilized to conceive these properties, but with the increasing number of available structures in databases or structure models produced by automated modeling frameworks this process requires assistance from tools that allow automated structure visualization. In this paper a web server and its underlying method for generating graphical sequence representations of molecular structures is presented. The method, called SequenceCEROSENE (color encoding of residues obtained by spatial neighborhood embedding), retrieves the sequence of each amino acid or nucleotide chain in a given structure and produces a color coding for each residue based on three-dimensional structure information. From this, color-highlighted sequences are obtained, where residue coloring represent three-dimensional residue locations in the structure. This color encoding thus provides a one-dimensional representation, from which spatial interactions, proximity and relations between residues or entire chains can be deduced quickly and solely from color similarity. Furthermore, additional heteroatoms and chemical compounds bound to the structure, like ligands or coenzymes, are processed and reported as well. To provide free access to SequenceCEROSENE, a web server has been implemented that allows generating color codings for structures deposited in the Protein Data Bank or structure models uploaded by the user. Besides retrieving visualizations in popular graphic formats, underlying raw data can be downloaded as well. In addition, the server provides user interactivity with generated visualizations and the three-dimensional structure in question. Color encoded sequences generated by SequenceCEROSENE can aid to quickly perceive the general characteristics of a structure of interest (or entire sets of complexes), thus supporting the researcher in the initial

  4. Method of inspecting the function of reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hirohito.

    1985-01-01

    Purpose: To enable to inspect the function of a reactor noise monitoring device used for monitoring the operation abnormality in coolant circuits during reactor operation. Constitution: A cylinder incorporating a steel ball moved laterally by a pneumatic pressure is disposed to the main body of a reactor coolant circuit. A three-way solenoid valve disposed to a central control room outside to a radiation controlled area is connected with the cylinder by way of pneumatic pipeways. The three-way solenoid valve is operated for a certain period of time by a timer in the central control room to thereby impinge the steel ball in the cylinder against the main body of the coolant circuit and it is inspected as to whether the reactor noise monitoring system can detect the impinging energy or not. Accordingly, the remote control is possible from out of the radiation controlled area and the inspection work can be simplified. (Seki, T.)

  5. Repeatability of Contour Method Residual Stress Measurements for a Range of Material, Process, and Geometry (Preprint)

    Science.gov (United States)

    2017-09-19

    stainless steel plate with a dissimilar metal slot-filled weld, a stainless steel forging, a titanium plate with an electron beam slot-filled weld, and a...stress 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT: SAR 18. NUMBER OF PAGES 27 19a. NAME OF RESPONSIBLE PERSON (Monitor) a...include: an aluminum T-section, a stainless steel plate with a dissimilar metal slot-filled weld, a stainless steel forging, a titanium plate with an

  6. System Health Monitoring Using a Novel Method: Security Unified Process

    Directory of Open Access Journals (Sweden)

    Alireza Shameli-Sendi

    2012-01-01

    and change management, and project management. The dynamic dimension, or phases, contains inception, analysis and design, construction, and monitoring. Risk assessment is a major part of the ISMS process. In SUP, we present a risk assessment model, which uses a fuzzy expert system to assess risks in organization. Since, the classification of assets is an important aspect of risk management and ensures that effective protection occurs, a Security Cube is proposed to identify organization assets as an asset classification model. The proposed model leads us to have an offline system health monitoring tool that is really a critical need in any organization.

  7. Pesticide residues in fruit samples: comparison of different QuEChERS methods using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Christia, C; Bizani, E; Christophoridis, C; Fytianos, K

    2015-09-01

    Acetate- and citrate-buffered quick, easy, cheap, effective, rugged, safe (QuEChERS) pretreatment methods were evaluated for the determination of various pesticides in peaches, grapes, apples, bananas, pears, and strawberries from various regions of Greece, using LC-MS/MS. The purposes of this study were (i) to evaluate which type of QuEChERS method was the most appropriate and effective for each matrix; (ii) to apply the selected QuEChERS method for each matrix, in order to detect and quantify pesticide residues in various fruit samples using UPLC-MS/MS; (iii) to examine the concentration distribution of pesticide classes among fruit originating from various areas; and (iv) to assess pesticide concentration distribution between peel and flesh of fruit in order to evaluate the penetration of pesticide residues in the fruit flesh. Acetate-buffered QuEChERS was found to be the most suitable technique for most of the fruit matrices. According to the recovery values at two different concentration levels, peaches should preferably be treated by the citrate-buffered type, whereas grapes, bananas, apples, pears, and strawberries are best treated by the acetate-buffered version, although the differences in efficiency were small. The addition of graphitized carbon black significantly decreases the recovery of specific pesticides in all matrices except for strawberries. The majority of values do not exceed the official maximum residue levels set by the European Commission. Organophosphates proved to be the most commonly detected category along with triazines-triazoles-conazoles group and by carbamates. Apples and pears seem to be the most contaminated fruit matrices among those tested. Distribution of pesticide classes shows variations between different regions, suggesting different pesticide application practices. In the case of peaches and pears, there is an equal distribution of detected pesticides between peel and flesh, indicating penetration of contaminants into the

  8. Reported prevalence and quantitative LC-MS methods for the analysis of veterinary drug residues in honey: a review.

    Science.gov (United States)

    Venable, Ryan; Haynes, Carion; Cook, Jo Marie

    2014-04-01

    Insect pollination increases the value and productivity of three-quarters of crop species grown for food. Declining beehive health in commercial apiaries has resulted in numerous reports from government laboratories worldwide of contamination with antimicrobial chemicals in honey. This review includes pertinent discussion of legislation and events leading to increased government oversight in the commercial honey market. A detailed summary of the variety and prevalence of veterinary drug residues being found in honey as well as a selection of robust quantitative and confirmatory LC-MS methods with an emphasis on those adopted by government testing laboratories are presented.

  9. Validation of a method for determination of amoxicillin residues applied to cleaning validation process in penicillins pharmaceutical industry

    OpenAIRE

    Gomes, Maria Luiza Pinheiro Costa; Souza, Scheilla Vitorino Carvalho de

    2010-01-01

    The aim of this work was the single-laboratory validation of a quantitative method for the determination of amoxicillin residues in support of cleaning control and validation. Linearity was demonstrated between 2.5 and 17.5 μg/mL, without matrix effects. Mean recoveries ranged from 84.00 to 103.74% and the relative standard deviation under repetitivity and within-reproducibility conditions were from 0.58 to 4.20% and from 0.79 to 4.39%, respectively. The theoretical limits of detection a...

  10. A Matching Method of Space-borne Laser Altimeter Big Footprint Waveform and Terrain Based on Cross Cumulative Residual Entropy

    Directory of Open Access Journals (Sweden)

    YUE Chunyu

    2017-03-01

    Full Text Available A matching method of space-borne laser altimeter big footprint waveform and terrain based on cross cumulative residual entropy(CCRE is proposed. Firstly, the waveform data and digital surface model(DSM data are projected to the statistics domain, according to the terrain structure information of the waveform, where statistics signal vectors of the two data are in the same dimension. Then, the waveform data and DSM image are matched in the statistics domain with CCRE. Experiments show that the algorithm proposed is effective in waveform and terrain matching, and the matching accuracy is within 1 pixel.

  11. Three State-of-the-Art Methods for Condition Monitoring

    NARCIS (Netherlands)

    Grimmelius, H.T.; Meiler, P.P.; Maas, H.L.M.M.; Bonnier, B.; Grevink, J.S.; Kuilenburg, R.F. van

    1999-01-01

    This paper describes and compares three different state-of-the-art condition monitoring techniques: first principles, feature extraction, and neural networks. The focus of the paper is on the application of the techniques, not on the underlying theory. Each technique is described briefly and is

  12. Simple method for monitoring rangeland health and wildlife habitat

    Science.gov (United States)

    We describe a monitoring system that requires just a pencil, one page datasheet and a 1-meter stick. Data are collected using the stick at five locations on each of four 25-m transects. Vegetation cover, composition, and horizontal and vertical structure are recorded by marking simple icons on the s...

  13. Time-frequency methods for structural health monitoring

    NARCIS (Netherlands)

    Pyayt, A.L.; Kozionov, A.P.; Mokhov, I.I.; Lang, B.; Meijer, R.J.; Krzhizhanovskaya, V.V.; Sloot, P.M.A.

    2014-01-01

    Detection of early warning signals for the imminent failure of large and complex engineered structures is a daunting challenge with many open research questions. In this paper we report on novel ways to perform Structural Health Monitoring (SHM) of flood protection systems (levees, earthen dikes and

  14. Handbook of drug monitoring methods: therapeutics and drugs of abuse

    National Research Council Canada - National Science Library

    Dasgupta, Amitava

    2008-01-01

    ... centers in the United States, academic medical centers, and reference laboratories. These centers not only employ immunoassays but also take advantage of sophisticated analytical techniques such as gas chromatography/mass spectrometry and high-performance liquid chromatography coupled with mass spectrometry for therapeutic drug-monitoring services. S...

  15. Balanced monitoring of flow phenomena in moving mesh methods

    NARCIS (Netherlands)

    van Dam, A.; Zegeling, P.A.

    2010-01-01

    Adaptive moving mesh research usually focuses either on analytical derivations for prescribed solutions or on pragmatic solvers with challenging physical applications. In the latter case, the monitor functions that steer mesh adaptation are often defined in an ad-hoc way. In this paper we generalize

  16. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  17. Residual damage in different ground logging methods alongside skid trails and winching strips

    Czech Academy of Sciences Publication Activity Database

    Aysan Badraghi, Naghimeg; Erler, J.; Hosseini, S. A. O.

    2015-01-01

    Roč. 61, č. 12 (2015), s. 526-534 ISSN 1212-4834 Institutional support: RVO:67179843 Keywords : Long-length method (LLM) * Short-length method (SLM) * Skidding and winching operations * Tree-length method (TLM) Subject RIV: EF - Botanics

  18. Mechanized methods for harvesting residual biomass from Mediterranean fruit tree cultivations

    Directory of Open Access Journals (Sweden)

    Borja Velázquez-Martí

    2012-06-01

    Full Text Available This study evaluates the technology and work systems used in order to harvest residual biomass from pruning in the specific conditions of Mediterranean fruit orchards (narrow distances between crop-rows. Harvesting has been divided into several types of operations - pruning, biomass alignment between crop tracks, biomass concentration in piles, chipping and bundling - which have been analyzed in five Mediterranean cultivations for three years. Altogether, three types of pruning have been analyzed: Manual, previous mechanical followed by manual, and fully mechanical; Two types of alignment: Manual and mechanical; Three concentration systems: Manual, tractor with a rake and a forwarder; Four chipping work organization systems: chipper driven inside orchard and manually fed by operators, mobile chipper driven inside orchard with pick-up header, mobile chipper fed by means of mechanical crane, chipper mounted on a truck fed by means of mechanical crane, which was working in a fixed position in a border of the plot after wood concentration. Also two bundling organization systems were checked: bundler machine working in a fixed position after wood concentration and working inside the plot driven among the crops. Previous concentration of the materials was the best alternative for their chipping or bundling in the studied conditions. Regression models have been calculated to predict the time of work of machinery and labor for each alternative. These equations were used to implement logistic planning as the Borvemar model, which defines a logistics network for supplying bio-energy systems.

  19. Validation of an efficient method for the determination of pesticide residues in fruits and vegetables using ethyl acetate for extraction.

    Science.gov (United States)

    Aysal, Perihan; Ambrus, Arpád; Lehotay, Steven J; Cannavan, Andrew

    2007-01-01

    In this study, a version of the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method was modified to use ethyl acetate (EtOAc) rather than acetonitrile (MeCN) for extraction in the determination of multiple pesticide residues in fruits and vegetables. EtOAc is better suited than MeCN for gas chromatographic (GC) analysis with electron capture detection (ECD) and nitrogen-phosphorus detection (NPD). The method entailed extraction of 30 g chopped sample plus 5 g NaHCO(3) and 30 g anhydrous Na(2)SO(4) with 60 mL EtOAc using a probe blender. After a centrifugation step, removal of residual water and cleanup were performed using dispersive solid-phase extraction (dispersive-SPE) with MgSO(4) and primary secondary amine (PSA) sorbent. (14)C-labeled chlorpyrifos with liquid scintillation counting was used to assist in optimizing and characterizing the method, and GC-ECD and GC-NPD were used for analysis of 24 selected pesticides. The method was validated using tomato, apple and frozen green bean matrices spiked at 0.05, 0.5, and 5 mg/kg. For 22 of the analytes, recoveries averaged 93% for all three commodities over the validation range with a relative standard deviation of 10% (n = 1182). Lower recoveries of dichlorvos were obtained with the method and iprodione determination was compromised in the green beans by an interfering peak. Typical limits of detection were 0.005-0.01 mg/kg with the method.

  20. Novelty detection methods for online health monitoring and post data analysis of turbopumps

    International Nuclear Information System (INIS)

    Lei Hu; Niaoqing, Hu; Xinpeng, Zhang; Fengshou, Gu; Ming, Gao

    2013-01-01

    As novelty detection works when only normal data are available, it is of considerable promise for health monitoring in cases lacking fault samples and prior knowledge. We present two novelty detection methods for health monitoring of turbopumps in large-scale liquid propellant rocket engines. The first method is the adaptive Gaussian threshold model. This method is designed to monitor the vibration of the turbopumps online because it has minimal computational complexity and is easy for implementation in real time. The second method is the one-class support vector machine (OCSVM) which is developed for post analysis of historical vibration signals. Via post analysis the method not only confirms the online monitoring results but also provides diagnostic results so that faults from sensors are separated from those actually from the turbopumps. Both of these two methods are validated to be efficient for health monitoring of the turbopumps.

  1. GIS applied to agriclimatological zoning and agrotoxin residue monitoring in tomatoes: A case study in Espírito Santo state, Brazil.

    Science.gov (United States)

    dos Santos, Gleissy Mary Amaral Dino Alves; Dos Santos, Alexandre Rosa; Teixeira, Luciano José Quintão; Saraiva, Sérgio Henriques; Freitas, Deivid França; Pereira, Olavo dos Santos; Ribeiro, Carlos Antonio Alvares Soares; Lorenzon, Alexandre Simões; Eugenio, Fernando Coelho; Neves, Antônio Augusto; de Queiroz, Maria Eliana Lopes Ribeiro; Scherer, Rodrigo

    2016-01-15

    Searches related to global warming have provided important insights into the response of terrestrial ecosystems, but few have examined the impacts on agricultural crops, particularly those associated with the monitoring of agrotoxin residues. In this context, the agriclimatological zoning is an important tool in the planning and consolidation of crops and should be considered in any initiative that involves such planning. This tool is particularly important in the analysis of agrotoxin residues and may be applied by the Program Analysis of Agrotoxin Residues in Food (PARA) created by the National Health Vigilance Agency of Brazil (ANVISA), which enables greater food security and contributes to the improvement of human health. The aim of this study was to elaborate the current and future agriclimatological zoning for the tomato crop, relating it with the monitoring of samples collected by PARA in Espírito Santo State, Brazil. The results indicate that a temperature increase of 5 °C creates a decrease in apt areas from 37.3% to 4.3%, for a total reduction of 33 percentage points (-88.5%). It is noted that of the 41 producing municipalities, only 26 have apt areas greater than 50%, highlighting the municipalities with apt areas greater than 90%, represented by Mantenópolis (100%), Guaçuí (98.5%), São José do Calçado (97.8%), Irupi (94.4%), Santa Teresa (92.3%), and Marechal Floriano (91.4%). The veracity of agriclimatological zoning is proved by a Kendall rank correlation coefficient of 0.876, indicating that the distribution of the variables of apt areas and productivity are similar at the significance level of 0.05 with a confidence interval 95%. After validation of the agriclimatological zoning for the tomato crop, it is recommended that the PARA should monitor 36 municipalities rather than the current 18, representing an increase of 100%. The methodology can be adjusted to agricultural crops of other countries. Copyright © 2015 Elsevier Ltd. All rights

  2. Multipesticide residue levels in UHT and raw milk samples by GC-μECD after QuEChER extraction method.

    Science.gov (United States)

    Jawaid, Sana; Talpur, Farah N; Nizamani, Shafi M; Khaskheli, Abid A; Afridi, H I

    2016-04-01

    In the present study, milk samples including raw and ultra-high temperature (UHT) processed milk were analyzed for pesticide residue levels, including five pesticides, viz chloripyrifos, endosulfan (α and β), profenofos and bifenthrin by gas chromatography microelectron capture detector (GC-μECD) after extraction by QuEChERS method. Further confirmation of the pesticide residue was done by GC-MS. The pesticide residual level in raw and UHT milk samples (n = 70) was determined in the range of 0.1-30 μg L(-1). All UHT processed milk samples contain pesticide residues within permissible limit set by the World Health Organization (WHO); however, among raw milk samples, chloripyrifos (12 %), α (24 %), and β (14 %) endosulfan were found above the maximum residue limit (MRL). The estimated daily intake (EDI) of these four pesticide residues were also calculated as 1.32, 16.16, 5.30, 10.20, and 9.93 μg kg(-1) body weight for chloripyrifos, endosulfan α, profenofos, endosulfan β, and bifenthrin, respectively. It is concluded that the raw milk samples showed higher prevalence of pesticide residues as compared to UHT processed milk. Graphical abstract Determination of pesticide residues in dairy milk by GC-μECD after QuEChERS extraction method.

  3. A review of monitoring methods for pharmaceutical wet granulation.

    Science.gov (United States)

    Hansuld, E M; Briens, L

    2014-09-10

    High-shear wet granulation is commonly used in the pharmaceutical industry to improve powder properties for downstream processes such as tabletting. Granule growth, however, is difficult to predict because the process is sensitive to raw material properties and operating conditions. Development of process analytical technologies is encouraged by regulatory bodies to improve process understanding and monitor quality online. The primary technologies investigated for high-shear wet granulation monitoring include power consumption, near-infrared spectroscopy, Raman spectroscopy, capacitance measurements, microwave measurements, imaging, focused beam reflectance measurements, spatial filter velocimetry, stress and vibration measurements, as well as acoustic emissions. This review summarizes relevant research related to each of these technologies and discusses the challenges associated with each approach as a possible process analytical technology tool for high-shear wet granulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Fault diagnosis method for area gamma monitors in Nuclear Facilities

    International Nuclear Information System (INIS)

    Srinivas Reddy, P.; Amudhu Ramesh Kumar, R.; Geo Mathews, M.; Amarendra, G.

    2016-01-01

    Area Gamma Monitors (AGM) using Geiger-Muller (GM) counter are deployed in nuclear facilities for detection of gamma radiation. The AGMs display the dose rate locally and in Data Acquisition System (DAS) at central monitoring station. It also provides local visual and audio alarms in case of dose rate exceeding alarm set point. Regular surveillance checking, testing and calibration of AGMs are mandatory as per safety guidelines. This paper describes quick testing the AGMs without using radioactive source. The four point High Voltages (HV) and Discriminator Bias (DB) voltage characteristics are used to diagnose the state of health of GM counter. The profiles of HV and DB voltage are applied during testing of the AGMs

  5. Digital Cavity Resonance Monitor, alternative method of measuring cavity microphonics

    International Nuclear Information System (INIS)

    Tomasz Plawski; G. Davis; Hai Dong; J. Hovater; John Musson; Thomas Powers

    2005-01-01

    As is well known, mechanical vibration or microphonics in a cryomodule causes the cavity resonance frequency to change at the vibration frequency. One way to measure the cavity microphonics is to drive the cavity with a Phase Locked Loop. Measurement of the instantaneous frequency or PLL error signal provides information about the cavity microphonic frequencies. Although the PLL error signal is available directly, precision frequency measurements require additional instrumentation, a Cavity Resonance Monitor (CRM). The analog version of such a device has been successfully used for several cavity tests [1]. In this paper we present a prototype of a Digital Cavity Resonance Monitor designed and built in the last year. The hardware of this instrument consists of an RF downconverter, digital quadrature demodulator and digital processor motherboard (Altera FPGA). The motherboard processes received data and computes frequency changes with a resolution of 0.2 Hz, with a 3 kHz output bandwidth

  6. Quantitative Clinical Imaging Methods for Monitoring Intratumoral Evolution.

    Science.gov (United States)

    Kim, Joo Yeun; Gatenby, Robert A

    2017-01-01

    regional dynamics so that the internal diversity of tumors is the net result of complex multiscale somatic Darwinian interactions.Methods in landscape ecology harness Darwinian dynamics to link the environmental properties of a given region to the local populations which are assumed to represent maximally fit phenotypes within those conditions. Consider a common task of a landscape ecologist: defining the spatial distribution of species in a large region, e.g., in a satellite image. Clearly the most accurate approach requires a meter by meter survey of the multiple square kilometers in the region of interest. However, this is both impractical and potentially destructive. Instead, landscape ecology breaks the task into component parts relying on the Darwinian interdependence of environmental properties and fitness of specific species' phenotypic and genotypic properties. First, the satellite map is carefully analyzed to define the number and distribution of habitats. Then the species distribution in a representative sampling of each habitat is empirically determined. Ultimately, this permits sufficient bridging of spatial scales to accurately predict spatial distribution of plant and animal species within large regions.Currently, identifying intratumoral subpopulations requires detailed histological and molecular studies that are expensive and time consuming. Furthermore, this method is subject to sampling bias, is invasive for vital organs such as the brain, and inherently destructive precluding repeated assessments for monitoring post-treatment response and proteogenomic evolution. In contrast, modern cross-sectional imaging can interrogate the entire tumor noninvasively, allowing repeated analysis without disrupting the region of interest. In particular, magnetic resonance imaging (MRI) provides exceptional spatial resolution and generates signals that are unique to the molecular constituents of tissue. Here we propose that MRI scans may be the equivalent of satellite

  7. Effects of residual feed intake classification and method of alfalfa processing on ewe intake and growth.

    Science.gov (United States)

    Redden, R R; Surber, L M M; Grove, A V; Kott, R W

    2014-02-01

    The objective of this research was to evaluate the effects of residual feed intake (RFI) determined under ad libitum feeding conditions on DMI and performance of yearling ewes fed either chopped or pelleted alfalfa hay. In Exp. 1, 45 ewe-lambs had ad libitum access to a pelleted grower diet for 63 d and individual DMI was determined using an electronic feed delivery system. Residual feed intake values were assigned to each ewe-lamb as a measure of feed efficiency. Sixteen ewe-lambs with the most positive RFI values were classified as high RFI (inefficient) and 16 ewe-lambs with the most negative RFI values were classified as low RFI (efficient). In Exp. 2, half of the ewes from each efficiency group were placed into 1 of 2 pens and provided ad libitum access to either pelleted or chopped alfalfa hay. Individual DMI was again determined using an electronic feed delivery system. Body weight, LM area (LMA), and 12th-rib back fat thickness (BF) were measured at the beginning and end of both experiments. In Exp. 1, DMI by ewe-lambs in the low RFI group was 9% less (P = 0.01) than by ewe-lambs in the high RFI group (2.21 vs. 2.43 kg/d); however, ADG and initial and final BW, LMA, and BF did not differ (P > 0.27) among RFI groups. In Exp. 2, there were no feed processing × RFI group interactions (P > 0.14) for any trait. By design, RFI values were lower (P ewes in the low than high RFI group (-0.27 vs. 0.27); however, RFI values did not differ (P = 1.0) between yearling ewes fed chopped versus pelleted alfalfa. Dry matter intake was 22% less (P ewes in the low than high RFI group (2.5 vs. 3.2 kg/d) and 59% less (P ewes fed chopped versus pelleted alfalfa (2.2 vs. 3.5 kg/d). Initial and final BW, ADG, and G:F did not differ (P > 0.45) between RFI groups but were greater (P ewes fed pelleted alfalfa compared to chopped alfalfa. Final LMA did not differ (P = 0.77) between RFI groups, but final BF tended to be greater (P = 0.06) for high than low RFI yearling ewes (0.63 vs

  8. Comparative analysis of three different methods for monitoring the use of green bridges by wildlife.

    Directory of Open Access Journals (Sweden)

    Goran Gužvica

    Full Text Available Green bridges are used to decrease highly negative impact of roads/highways on wildlife populations and their effectiveness is evaluated by various monitoring methods. Based on the 3-year monitoring of four Croatian green bridges, we compared the effectiveness of three indirect monitoring methods: track-pads, camera traps and active infrared (IR trail monitoring system. The ability of the methods to detect different species and to give good estimation of number of animal crossings was analyzed. The accuracy of species detection by track-pad method was influenced by granulometric composition of track-pad material, with the best results obtained with higher percentage of silt and clay. We compared the species composition determined by track-pad and camera trap methods and found that monitoring by tracks underestimated the ratio of small canids, while camera traps underestimated the ratio of roe deer. Regarding total number of recorder events, active IR detectors recorded from 11 to 19 times more events then camera traps and app. 80% of them were not caused by animal crossings. Camera trap method underestimated the real number of total events. Therefore, an algorithm for filtration of the IR dataset was developed for approximation of the real number of crossings. Presented results are valuable for future monitoring of wildlife crossings in Croatia and elsewhere, since advantages and disadvantages of used monitoring methods are shown. In conclusion, different methods should be chosen/combined depending on the aims of the particular monitoring study.

  9. Application of a new containment and surveillance portal monitor data analysis method

    International Nuclear Information System (INIS)

    Pratt, J.C.; Henry, C.N.; Hastings, R.D.

    1980-01-01

    A new method for processing the information available from an ordinary doorway monitor in an earlier report is described. Additional tests of this concept on doorway monitors at facilities of the Los Alamos Scientific Laboratory have been made. The lessons learned and estimates of the sensitivity of this method for detection of a trickle of special nuclear material through the portal are presented

  10. Comparative analysis of three different methods for monitoring the use of green bridges by wildlife.

    Science.gov (United States)

    Gužvica, Goran; Bošnjak, Ivana; Bielen, Ana; Babić, Danijel; Radanović-Gužvica, Biserka; Šver, Lidija

    2014-01-01

    Green bridges are used to decrease highly negative impact of roads/highways on wildlife populations and their effectiveness is evaluated by various monitoring methods. Based on the 3-year monitoring of four Croatian green bridges, we compared the effectiveness of three indirect monitoring methods: track-pads, camera traps and active infrared (IR) trail monitoring system. The ability of the methods to detect different species and to give good estimation of number of animal crossings was analyzed. The accuracy of species detection by track-pad method was influenced by granulometric composition of track-pad material, with the best results obtained with higher percentage of silt and clay. We compared the species composition determined by track-pad and camera trap methods and found that monitoring by tracks underestimated the ratio of small canids, while camera traps underestimated the ratio of roe deer. Regarding total number of recorder events, active IR detectors recorded from 11 to 19 times more events then camera traps and app. 80% of them were not caused by animal crossings. Camera trap method underestimated the real number of total events. Therefore, an algorithm for filtration of the IR dataset was developed for approximation of the real number of crossings. Presented results are valuable for future monitoring of wildlife crossings in Croatia and elsewhere, since advantages and disadvantages of used monitoring methods are shown. In conclusion, different methods should be chosen/combined depending on the aims of the particular monitoring study.

  11. Prediction of hot spot residues at protein-protein interfaces by combining machine learning and energy-based methods

    Directory of Open Access Journals (Sweden)

    Pontil Massimiliano

    2009-10-01

    Full Text Available Abstract Background Alanine scanning mutagenesis is a powerful experimental methodology for investigating the structural and energetic characteristics of protein complexes. Individual amino-acids are systematically mutated to alanine and changes in free energy of binding (ΔΔG measured. Several experiments have shown that protein-protein interactions are critically dependent on just a few residues ("hot spots" at the interface. Hot spots make a dominant contribution to the free energy of binding and if mutated they can disrupt the interaction. As mutagenesis studies require significant experimental efforts, there is a need for accurate and reliable computational methods. Such methods would also add to our understanding of the determinants of affinity and specificity in protein-protein recognition. Results We present a novel computational strategy to identify hot spot residues, given the structure of a complex. We consider the basic energetic terms that contribute to hot spot interactions, i.e. van der Waals potentials, solvation energy, hydrogen bonds and Coulomb electrostatics. We treat them as input features and use machine learning algorithms such as Support Vector Machines and Gaussian Processes to optimally combine and integrate them, based on a set of training examples of alanine mutations. We show that our approach is effective in predicting hot spots and it compares favourably to other available methods. In particular we find the best performances using Transductive Support Vector Machines, a semi-supervised learning scheme. When hot spots are defined as those residues for which ΔΔG ≥ 2 kcal/mol, our method achieves a precision and a recall respectively of 56% and 65%. Conclusion We have developed an hybrid scheme in which energy terms are used as input features of machine learning models. This strategy combines the strengths of machine learning and energy-based methods. Although so far these two types of approaches have mainly been

  12. Large-scale monitoring of effects of clothianidin-dressed oilseed rape seeds on pollinating insects in northern Germany: residues of clothianidin in pollen, nectar and honey.

    Science.gov (United States)

    Rolke, Daniel; Persigehl, Markus; Peters, Britta; Sterk, Guido; Blenau, Wolfgang

    2016-11-01

    This study was part of a large-scale monitoring project to assess the possible effects of Elado ® (10 g clothianidin & 2 g β-cyfluthrin/kg seed)-dressed oilseed rape seeds on different pollinators in Northern Germany. Firstly, residues of clothianidin and its active metabolites thiazolylnitroguanidine and thiazolylmethylurea were measured in nectar and pollen from Elado ® -dressed (test site, T) and undressed (reference site, R) oilseed rape collected by honey bees confined within tunnel tents. Clothianidin and its metabolites could not be detected or quantified in samples from R fields. Clothianidin concentrations in samples from T fields were 1.3 ± 0.9 μg/kg and 1.7 ± 0.9 μg/kg in nectar and pollen, respectively. Secondly, pollen and nectar for residue analyses were sampled from free flying honey bees, bumble bees and mason bees, placed at six study locations each in the R and T sites at the start of oilseed rape flowering. Honey samples were analysed from all honey bee colonies at the end of oilseed rape flowering. Neither clothianidin nor its metabolites were detectable or quantifiable in R site samples. Clothianidin concentrations in samples from the T site were below the limit of quantification (LOQ, 1.0 µg/kg) in most pollen and nectar samples collected by bees and 1.4 ± 0.5 µg/kg in honey taken from honey bee colonies. In summary, the study provides reliable semi-field and field data of clothianidin residues in nectar and pollen collected by different bee species in oilseed rape fields under common agricultural conditions.

  13. Further studies on the use of enzyme profiles to monitor residue accumulation in wildlife: Plasma enzymes in starlings fed graded concentrations of morsodren, DDE, Aroclor 1254, and malathion

    Science.gov (United States)

    Dieter, M.P.

    1975-01-01

    Wild-trapped starlings (Sturnus vulgaris) were fed concentrations of Morsodren (2, 4, and 8 ppm), DDE or Aroclor 1254 (5, 25, and 100 ppm), or malathion (8, 35, and 160 ppm) that were found to be sublethal in pen-reared Coturnix quail fed these amounts for 12 weeks. Plasma enzymes had to be measured earlier than planned in starlings fed Morsodren (at three weeks) or the organochlorine compounds (at seven weeks) because of unexpected, subsequent mortality. Variations in enzyme response were greater in wild than in pen-reared birds, but not enough to mask the toxicant-induced changes in enzyme activity. Cholinesterase activities decreased in birds fed Morsodren or malathion, and increased in those fed the organochlorine compounds. Lactate dehydrogenase activities increased two-fold in starlings fed Morsodren and two- to four-fold in those fed the organochlorine compounds, but only 50% in those fed malathion. Further examination of enzyme profiles showed that creatine kinase and aspartate aminotransferase activities increased two-to four-fold in birds fed Morsodren or the organochlorine compounds but not at all in those fed malathion. Thus the classes of environmental contaminants fed to starlings could be easily distinguished by these enzymatic parameters. Evaluation of enzymatic profiles appears to be a potentially valuable technique to monitor the presence of toxicants in wild populations, especially if used to complement standard chemical residue analyses. Here the residue analyses showed, after three weeks feeding, that mercury in the carcasses reflected the concentrations fed daily, whereas accumulation in the livers was two- to four-fold greater. After seven weeks feeding, liver residues of either organochlorine compound were about three-fold higher than the concentrations fed daily. However, four times as much DDE as Aroclor 1254 had accumulated in the carcasses.

  14. VALIDATION HPLC METHOD FOR THE DETERMINATION OF CLONIDINE HYDROCHLORIDE RESIDUES FROM PHARMACEUTICAL MANUFACTURING EQUIPMENT

    Directory of Open Access Journals (Sweden)

    A. V. Yegorova

    2015-04-01

    Full Text Available Highly sensitive HPLC method of determination of clonidine hydrochloride trace amounts for validation cleaning process of the pharmaceutical equipment has been proposed. The developed method has been validated on the following parameters: specificity, linearity, precision, limit of detection and limit of quantification. The calibration curve was linear over the concentration range of 0.1-6.0 mg / ml, the limit of detection is 0.026 μg/ml. It has been found that clonidine hydrochloride solutions are stable for 48 hours. Effectiveness of the method of sampling is more than 95%.

  15. Preliminary validation of high performance liquid chromatography method for detection of methyl-testosterone residue in carp muscle

    Science.gov (United States)

    Jiang, Jie; Lin, Hong; Fu, Xiaoting; Li, Mingming

    2005-07-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethane-methanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy) at the 1, 5 and l0 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation (RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10% for muscle tissue. The limit of detection was 0.05 mgkg-1.

  16. Evaluation of the localized residual strain states of GaN layers by using a TEM-CBED method

    International Nuclear Information System (INIS)

    Shin, H. Y.; Chang, Y. I.; Jung, Y. W.; Cho, M. J.; Park, K. H.

    2006-01-01

    The convergent beam electron diffraction (CBED) method of transmission electron microscopy (TEM) is well known to be a useful technique for evaluating the localized residual strain by measuring the quantitative variations of the lattice parameters. The multi quantum wells (MQWs) affect on the localized residual strain in a GaN layer, where the AlGaN layer is deposited in order to reduce the strain. We used TEM in order to determine the variations of the lattice parameters of the GaN layer both with and without the AlGaN layer. The lattice parameters of the GaN layer were measured every 100 nm along to the transverse direction below the MQWs. The lattice parameters of the lower part of the GaN layer were shown to have lower values than those of the higher part (below MQWs), which is caused by the compressive stress formed by the sapphire substrate. Also, due to the tensile stress formed by an InGaN in the MQWs, the lattice parameters of the higher part were shown to have higher values. The AlGaN layer deposited on the MQWs produced a compressive stress on the GaN layer so that the average lattice parameters of the GaN layer with the AlGaN layer were lower than those without the AlGaN layer. Therefore, we conclude that the AlGaN layer plays a role in reducing the localized residual strain on the GaN layer below the MQWs.

  17. Method and apparatus for monitoring plasma processing operations

    Science.gov (United States)

    Smith, Jr., Michael Lane; Ward, Pamela Denise Peardon; Stevenson, Joel O'Don

    2002-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). Another aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system. A final aspect of the present invention relates to a network a plurality of plasma monitoring systems, including with remote capabilities (i.e., outside of the clean room).

  18. Monitoring of Landslide Areas with the Use of Contemporary Methods of Measuring and Mapping

    Directory of Open Access Journals (Sweden)

    Skrzypczak Izabela

    2017-03-01

    Full Text Available In recent years, there is an increase of landslide risk observed, which is associated with intensive anthropogenic activities and extreme weather conditions. Appropriate monitoring and proper development of measurements resulting as maps of areas at risk of landslides enables us to estimate the risk in the social and economic aspect. Landslide monitoring in the framework of SOPO project is performed by several methods of measurements: monitoring of surface (GNSS measurement and laser scanning, monitoring in-deepth (inclinometer measurements and monitoring of the hydrological changes and precipitation (measuring changes in water-table and rainfall.

  19. Monitoring the residual life of atomic power station equipment based on the indices of stress-corrosion strength of constructional materials

    International Nuclear Information System (INIS)

    Stepanov, I.A.

    1994-01-01

    The properties of a constructional material determining life are strength, plasticity, and crack resistance. Loss of properties occurs as the result of corrosion, temperature action, actual and residual stresses, and neutron and gamma-radiation. Corrosion leads to a decrease in thickness, loss of density, changes in the composition and structure of the surface layers, and a reduction in strength, plasticity, and crack resistance of constructional materials. The influence of temperature on the loss of properties of materials is revealed as possible phase and structural transformations of the metal and the surface layers and a reduction in the stress-rupture, plastic, and thermal-fatigue properties. The actual and residual stresses not only strengthen the influence of corrosive media but also directly determine the stress-rupture strength and cyclic life. The influence of neutron and gamma-radiation is based o the change in composition of the corrosive medium (radiolysis), radiation embrittlement of the material, and the change in properties of the surface and oxide layers. The authors discuss the concepts and design of automated monitoring systems for determining the fitness of the components of on atomic power plant

  20. Residue behaviors and dietary risk assessment of dinotefuran and its metabolites in Oryza sativa by a new HPLC-MS/MS method.

    Science.gov (United States)

    Li, Ruijuan; Liu, Tongjin; Cui, Shuhua; Zhang, Sicong; Yu, Jianlei; Song, Guochun

    2017-11-15

    In this study, we developed a new method to detect dinotefuran and its metabolites (UF and DN) in Oryza sativa (Rice) by HPLC-MS/MS in multiple reaction monitoring (MRM) modes. The recovery rates for dinotefuran, UF and DN were 82.3-85.8%, 83.7-89.0%, and 81.6-90.2%, respectively. The dissipation kinetics of dinotefuran in rice followed a combined first+first kinetic model, where the half-lives of dinotefuran and its metabolites were determined to be between 0.5 and 2.3days. The dinotefuran residue in brown rice sampled at day 7, 14, and 21 after the last application was 0.4131mg/kg with a very low risk quotient (RQ) value. We recommend that the safety interval of application for rice is 7days. The method developed in this study is simple and rapid, with high accuracy and precision which meet the requirements for quantitative analysis of dinotefuran in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A multi-residue method for determination of 70 organic micropollutants in surface waters by solid-phase extraction followed by gas chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Terzopoulou, Evangelia; Voutsa, Dimitra; Kaklamanos, George

    2015-01-01

    A multi-residue method, based on gas chromatography coupled to tandem mass spectrometry (GC-MS/MS), has been developed for the determination of 70 organic micropollutants from various chemical classes (organochlorinated, organophosphorous, triazines, carbamate and urea, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, pharmaceuticals, phenols, etc.) in surface waters. A single-step SPE extraction using OASIS HLB cartridges was employed for the recovery of target micropollutants. The method has been validated according to monitoring performance criteria of the Water Framework Directive, taking into account the approved guidelines on quality assurance and quality control. The recoveries ranged from 60 to 110 %, the coefficient of variation from 0.84 to 27.4 %, and the uncertainty from 6 to 37 %. The LOD varied from 6.0 to 40 ng/L. The limits of quantification for the priority pollutants anthracene, alachlor, atrazine, benzo(a)pyrene, chlorfenvinphos, diuron, isoproturon, nonylphenol, simazine, and terbutryn fulfill the criterion of diuron, isoproturon, salicylic acid, chlorfenvinphos, 1,2-benzanthracene, pyrene, diflubenzuron, and carbaryl exhibited the highest detection frequencies.

  2. Flow cytometric minimal residual disease monitoring in children with acute lymphoblastic leukemia treated by regimens with reduced intensity

    Directory of Open Access Journals (Sweden)

    A. M. Popov

    2015-01-01

    Full Text Available 191 consecutive unselected children with acute lymphoblastic leukemia aged from 1 to 16 years were enrolled in the study. Bone marrow samples were obtained at the time of initial diagnostics as well as at days 15 (n = 188, 36 (n = 191, and 85 (n = 187 of remission induction. Minimal residual disease (MRD was assessed by 6–10-color flow cytometry. Flow cytometry data at day 15 allowed distinguishing three patients groups with significantly different outcome (p ˂ 0.0001: 35.64 % patients with MRD < 0.1 % represented 5-year event-free survival (EFS of 100 %; 48.40 % cases with 0.1 % ≤ MRD< 10 % had EFS 84.6 ± 4.2 %; 15.96 % patients with very high MRD (≥ 10 % belonged to group with poor outcome (EFS 56.7 ± 9.0 %. At the end of remission induction (day 36 36 children (18.85 % with MRD higher than 0.1 % had significantly worse outcome compared to remaining ones (EFS 49.4 ± 9.0 and 93.5 ± 2.1 % respectively; p ˂ 0.0001. From a clinical standpoint it is relevant to evaluate both low-risk and high-risk criteria. Multivariate analysis showed that day 15 MRD data is better for low-risk patients definition while end-induction MRD is the strongest unfavorable prognostic factor.

  3. Control and monitoring method and system for electromagnetic forming process

    Science.gov (United States)

    Kunerth, Dennis C.; Lassahn, Gordon D.

    1990-01-01

    A process, system, and improvement for a process for electromagnetic forming of a workpiece in which characteristics of the workpiece such as its geometry, electrical conductivity, quality, and magnetic permeability can be determined by monitoring the current and voltage in the workcoil. In an electromagnet forming process in which a power supply provides current to a workcoil and the electromagnetic field produced by the workcoil acts to form the workpiece, the dynamic interaction of the electromagnetic fields produced by the workcoil with the geometry, electrical conductivity, and magnetic permeability of the workpiece, provides information pertinent to the physical condition of the workpiece that is available for determination of quality and process control. This information can be obtained by deriving in real time the first several time derivatives of the current and voltage in the workcoil. In addition, the process can be extended by injecting test signals into the workcoil during the electromagnetic forming and monitoring the response to the test signals in the workcoil.

  4. Geological and geophysical methods for monitoring of heritage structures

    Science.gov (United States)

    Kulynych, Anna

    2017-04-01

    Using the analysis of geological and geophysical survey of the soil conditions of the site where the architectural landmarks of Kyiv are concentrated the research proposes to develop an optimal set of geological and geophysical studies aimed at monitoring and evaluating the impact of underflooding, risk of landslide and increase of seismic magnitude on the upper portion of geological cross-section. The research offers suggestions concerning the establishment of a monitoring system for the principal sites where the architectural heritage is located. As the earthquake origins are not scattered randomly but located within the relatively narrow zones of active faults, that is, the places most exposed to rapid geodynamic shifts, active faults and blocks they form are one of the main signs for identifying potential seismogenic areas. From the point of view of the present geodynamic instability the morphostructural neotectonic points characterized by the high degree of tectonic fragmentation, including within the upper portion of the sedimentary cover, the high values of relief energy and activation of exogenous processes deserve special attention. The research develops the comparison of areas with increased seismic impacts allocated according to geophysical data with neotectonic structural plan, allows to conclude about their suitability for morphostructural neotectonic points and some sections of active faults exactly that is important to consider when constructing new buildings and protecting the existing ones.

  5. Comparison of NAA XRF and ICP-OES Methods on Analysis of Heavy Metals in Coals and Combustion Residues

    Directory of Open Access Journals (Sweden)

    Agus Taftazani

    2017-07-01

    Full Text Available Heavy metals in the samples of coals and combustion residues (bottom ash and fly ash from Pacitan coal-fired power plant (CPP have been identified by using NAA, XRF, and ICP-OES methods. This research was aimed to understand the analysis results correlation coefficient (R and determine the enrichment ratio (ER value of the samples by using three analysis methods. The results showed 10 elements have been simultaneously detected in all samples. The correlation coefficient of analysis results of metals content in coals by using NAA-XRF, XRF-ICP OES and with ICPOES-NAA methods gives R2£1 respectively. The correlation coefficient of analysis results of metals content in bottom ash and fly ash by using the methods of NAA-XRF, XRF-ICPOES, and ICPOES-NAA gained R2»1 respectively. ICP-OES method was most satisfactory in this study. The value of ER for identified metals by using the three methods in the samples of bottom ash and fly ash yielded the value over one, and ER value of fly ash was greater in comparison to the bottom ash.

  6. Comparison of two freshwater turtle species as monitors of radionuclide and chemical contamination: DNA damage and residue analysis

    International Nuclear Information System (INIS)

    Meyers-Schoene, L.; Shugart, L.R.; Beauchamp, J.J.; Walton, B.T.

    1993-01-01

    Two species of turtles that occupy different ecological niches were compared for their usefulness as monitors of freshwater ecosystems where both low-level radioactive and nonradioactive contaminants are present. The pond slider (Trachemys scripta) and common snapping turtle (Chelydra serpentina) were analyzed for the presence of 90 Sr, 137 Cs, 60 Co, and Hg, radionuclides and chemicals known to be present at the contaminated site, and single-strand breaks in liver DNA. The integrity of the DNA was examined by the alkaline unwinding assay, a technique that detects strand breaks as a biological marker of possible exposure to genotoxic agents. This measure of DNA damage was significantly increased in both species of turtles at the contaminated site compared with turtles of the same species at a reference site, and shows that contaminant-exposed populations were under more severe genotoxic stress than those at the reference site. The level of strand breaks observed at the contaminated site was high and in the range reported for other aquatic species exposed to deleterious concentrations of genotoxic agents such as chemicals and ionizing radiation. Statistically significantly higher concentrations of radionuclides and Hg were detected in the turtles from the contaminated area. Mercury concentrations were significantly higher in the more carnivorous snapping turtle compared with the slider; however, both species were effective monitors of the contaminants

  7. Ground-based ULF methods of monitoring the magnetospheric plasma

    Science.gov (United States)

    Romanova, Natalia; Pilipenko, Viacheslav; Stepanova, Marina; Kozyreva, Olga; Kawano, Hideaki

    The terrestrial magnetosphere is a giant natural MHD resonator. The magnetospheric Alfven resonator is formed by the geomagnetic field lines terminated by the conductive ionospheres. Though a source of Pc3-5 waves is not reliably known, the identification of resonant frequency enables one to determine the magnetospheric plasma density and ionospheric conductance from ground magnetometer observations. However, a spectral peak does not necessarily correspond to a local resonant frequency, and the width of a spectral peak cannot be directly used to determine the quality factor of the magnetospheric resonator. This ambiguity can be resolved with the help of various gradient and polarization methods, reviewed in this presentation: Gradient method (GM), Amplitude-Phase Gradient method (APGM),Polarization methods (including H/D method), and Hodograph (H) method. These methods can be regarded as tools for the "hydromagnetic spectroscopy“ to diagnose the magnetosphere. The H-method has additional possibilities as compared with the gradient method: one can determine continuous distribution of the magnetospheric resonant frequencies and Q-factors in the range of latitudes beyond the observation baseline. These methods are illustrated by results of their application to the SAMBA magnetometers array data.

  8. Development of a medication monitoring attitude measure using a mixed methods item development process.

    Science.gov (United States)

    Witry, Matthew J; Wesely, Pamela M; Goedken, Amber M; Ernst, Erika J; Sorofman, Bernard A; Doucette, William R

    2016-02-01

    Medication monitoring is important for safe and effective medication use; however, no attitudinal measure exists for a health care provider's medication monitoring attitude. The objectives of this study were to (1) create a measure of a community pharmacist medication monitoring attitude; (2) test concurrent validity using a validated measure of medication monitoring behaviours; and (3) report community pharmacist attitudes towards medication monitoring. A mixed methods item development process was employed to generate Likert-type items from qualitative interviews. Following item review and piloting, a four-contact survey, including 20 6-point Likert-type items and the four-item Behavioral Pharmaceutical Care Scale monitoring domain, was mailed to 599 randomly sampled US community pharmacists from the state of Iowa. Exploratory factor analysis, Pearson's correlation and descriptive statistics were used to address study objectives. There were 254 (42.4%) returned and usable surveys. Factor analysis yielded two domains, a seven-item, positively worded internal (α = 0.819) and an eight-item, negatively worded external domain (α = 0.811). Both domains were positively correlated with the monitoring domain of the Behavioral Pharmaceutical Care Scale supporting convergent validity. Overall, respondents had a positive internal monitoring attitude with a mean of 4.62 (0.68), although many practiced in an environment less conducive to monitoring, as evident by a mean of 3.13 (0.88). Pharmacists were more oriented towards medication side effect and effectiveness monitoring than nonadherence monitoring. The mixed methods item development process created a reliable and valid measure of a pharmacist's medication monitoring attitude. While pharmacists had an overall positive medication monitoring attitude, improvements are needed to bolster adherence monitoring and make pharmacy environments more conducive to monitoring. © 2015 Royal Pharmaceutical Society.

  9. Liquid chromatography-UV diode-array detection method for multi-residue determination of macrolide antibiotics in sheep's milk.

    Science.gov (United States)

    García-Mayor, M A; Garcinuño, R M; Fernández-Hernando, P; Durand-Alegría, J S

    2006-07-28

    A rapid, simple and sensitive liquid chromatography-UV diode-array detection method was developed for the simultaneous determination of seven macrolides (erythromycin, oleandomycin, roxithromycin, josamycin, spiramycin, tylosin and ivermectin) in sheep's milk. The column, mobile phase, temperature and flow rate were optimised to provide the best resolution of these analytes. The extraction of the antibiotic residues involves the treatment of protein-free samples with a combination of concentrated sodium hydroxide and ethyl acetate. Necessary defatting is achieved by alkaline hydrolysis. The recovery of each antibiotic was between 55% and 77%, with relative standard deviations ranging from 1% to 6.5%. The limit of quantification was 72.4 microg/kg for ivermectin, 48.3 microg/kg for roxithromycin, and 24.1 microg/kg for erythromycin, oleandomycin, spiramycin, josamycin and tylosin. The procedure was successfully used in the multi-residue determination of these macrolides at levels below the maximum concentrations legally allowed in milk samples.

  10. A method for computing the inter-residue interaction potentials for ...

    Indian Academy of Sciences (India)

    PRAKASH KUMAR

    2007-06-16

    Jun 16, 2007 ... Wish 1978), which provides a visual representation that gives a clue for rational grouping that accounts ... this fact and proposed a Venn diagram representation of the information contained in Dayhoff's matrix ... The MDS is a widely used method in social sciences and psychometry (Kruskal and Wish 1978).

  11. Method Development for Pesticide Residue Analysis in Farmland Soil using High Perfomance Liquid Chromatography

    Science.gov (United States)

    Theresia Djue Tea, Marselina; Sabarudin, Akhmad; Sulistyarti, Hermin

    2018-01-01

    A method for the determination of diazinon and chlorantraniliprole in soil samples has been developed. The analyte was extracted with acetonitrile from farmland soil sample. Determination and quantification of diazinon and chlorantraniliprole were perfomed by high perfomance liquid chromatography (HPLC) with an UV detector. Several parameters of HPLC method were optimized with respect to sensitivity, high resolution of separation, and accurate determination of diazinon and chlorantraniliprole. Optimum conditions for the separation of two pesticides were eluent composition of acetonitrile:water ratio of 60:40, 0.4 mL/min of flow rate, and 220 nm of wavelength. Under the optimum conditions, diazinon linearity was in the range from 1-25 ppm with R2 of 0.9976, 1.19 mgL-1 LOD, and 3.98 mgL-1 LOQ; while the linearity of chlorantraniliprole was in the range from 0.2-5 mgL-1 with R2 of 0.9972, 0.39 mgL-1 LOD, and 1.29 mgL-1 LOQ. When the method was applied to the soil sample, both pesticides showed acceptable recoveries for real sample of more than 85%: thus, the developed method meets the validation requirement. Under this developed method, the concentrations of both pesticides in the soil samples were below the LOD and LOQ (0.577 mgL-1 for diazinon and 0.007 mgL-1 for chlorantraniliprole). Therefore, it can be concluded that the soil samples used in this study have neither diazinon nor chlorantraniliprole.

  12. Carcinogenicity of residual fuel oils by nonbiological laboratory methods: annotated bibliography. Part I. Laboratory methods of analysis. Part II. Analysis results

    Energy Technology Data Exchange (ETDEWEB)

    Cichorz, R. S.

    1976-04-09

    Recent emphases have been directed by Federal government regulatory agencies and other research groups on the carcinogenic effects of certain aromatic hydrocarbon components in naturally occurring petroleum products. These are used in plant operations, and underline the importance of evaluating environments. Since Rocky Flats Plant uses large quantities of fuel oil, the author was prompted to undertake a search of the chemical literature. Articles and accounts of studies were reviewed on nonbiological laboratory methods for determining the carcinogenicity of residual fuel oils and related high-boiling petroleum fractions. The physical and chemical methods involve the separation or measurement (or both) of polynuclear aromatic constituents which generally are responsible for the carcinogenic effects. Thus, the author suggests that the total carcinogenic activity of any petroleum product may not be due to a specific potent carcinogen, but rather to the cumulative effect of several individually weak carcinogens. The literature search is presented as an annotated bibliography, current as of January 1, 1975, and includes significant parts of the studies along with the total number of other references found when the citation was examined in its entirety. Part I deals with laboratory chemical and physical methods of determining carcinogenicity or polynuclear aromatic hydrocarbons (or both) in residual fuel oils and contains ten entries. Part II includes the results of testing specific fuel oils for carcinogenic constituents and contains eleven entries. An author index and subject categories are included.

  13. Comprehensive methods for earlier detection and monitoring of forest decline

    Science.gov (United States)

    Jennifer Pontius; Richard Hallett

    2014-01-01

    Forested ecosystems are threatened by invasive pests, pathogens, and unusual climatic events brought about by climate change. Earlier detection of incipient forest health problems and a quantitatively rigorous assessment method is increasingly important. Here, we describe a method that is adaptable across tree species and stress agents and practical for use in the...

  14. Mekong Regional Land Cover Monitoring System Reference Methods

    Science.gov (United States)

    Saah, D.; Aekakkararungroj, A.; Phongsapan, K.; Towashiraporn, P.; Triepke, J.; Maus, P.; Tenneson, K.; Anderson, E.; Cutter, P. G.; Ganz, D.; Ate, P.; Markert, K. N.

    2016-12-01

    In 2015, SERVIR-Mekong conducted a geospatial needs assessment for the Lower Mekong countries which included individual country consultations. The assessment revealed that many countries were dependent on land cover and land use maps for land resource planning, quantifying ecosystem services including resilience to climate change, biodiversity conservation, and other critical social issues. Many of the Lower Mekong countries have developed national scale land cover maps derived in part from remote sensing products and geospatial technologies. However, updates are infrequent and classification systems and accuracy assessment do not always meet the needs of key user groups. In addition, data products stop at political boundaries and are often not accessible. Many of the Lower Mekong countries rely on global land cover products to fill the gaps of their national efforts, compromising consistency between data and policies. These gaps in national efforts can be filled by a flexible regional land cover monitoring system that is co-developed by regional partners with the specific intention of meeting national transboundary needs, for example including consistent forest definitions in transboundary watersheds. During this assessment, regional stakeholders identified a need for a land cover monitoring system that will produce frequent, high quality land cover maps using a consistent regional classification scheme that is compatible with national country needs. This system is dependent on a sustainable source of field data that insures data quality and improves potential impact. Based on this need a collaborative workshop was held to create a robust regional reference data system that integrates results from field data, national inventories and high resolution imagery. The results presented here highlights the value of collaboratively developed systems that use data convergence to improve land cover mapping results for multiple end users.

  15. New methods for the condition monitoring of level crossings

    Science.gov (United States)

    García Márquez, Fausto Pedro; Pedregal, Diego J.; Roberts, Clive

    2015-04-01

    Level crossings represent a high risk for railway systems. This paper demonstrates the potential to improve maintenance management through the use of intelligent condition monitoring coupled with reliability centred maintenance (RCM). RCM combines advanced electronics, control, computing and communication technologies to address the multiple objectives of cost effectiveness, improved quality, reliability and services. RCM collects digital and analogue signals utilising distributed transducers connected to either point-to-point or digital bus communication links. Assets in many industries use data logging capable of providing post-failure diagnostic support, but to date little use has been made of combined qualitative and quantitative fault detection techniques. The research takes the hydraulic railway level crossing barrier (LCB) system as a case study and develops a generic strategy for failure analysis, data acquisition and incipient fault detection. For each barrier the hydraulic characteristics, the motor's current and voltage, hydraulic pressure and the barrier's position are acquired. In order to acquire the data at a central point efficiently, without errors, a distributed single-cable Fieldbus is utilised. This allows the connection of all sensors through the project's proprietary communication nodes to a high-speed bus. The system developed in this paper for the condition monitoring described above detects faults by means of comparing what can be considered a 'normal' or 'expected' shape of a signal with respect to the actual shape observed as new data become available. ARIMA (autoregressive integrated moving average) models were employed for detecting faults. The statistical tests known as Jarque-Bera and Ljung-Box have been considered for testing the model.

  16. Validation of QuEChERS method for the determination of some pesticide residues in two apple varieties.

    Science.gov (United States)

    Tiryaki, Osman

    2016-10-02

    This study was undertaken to validate the "quick, easy, cheap, effective, rugged and safe" (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.

  17. Multi-residue method for detecting coccidiostats at carry-over level in feed by HPLC-MS/MS.

    Science.gov (United States)

    Delahaut, Ph; Pierret, G; Ralet, N; Dubois, M; Gillard, N

    2010-06-01

    A multi-residue HPLC-ESI-MS/MS method has been developed for the simultaneous extraction, detection and confirmation of the 11 coccidiostats referenced by Regulation 2009/8/EC (lasalocid sodium, narasin, salinomycin sodium, monensin sodium, semduramicin sodium, maduramicin ammonium alpha, robenidine hydrochloride, decoquinate, halofuginone hydrobromide, nicarbazin, and diclazuril) in feedstuffs at carry-over level. The sensitivity of the method allows quantification and confirmation for all coccidiostats below target concentration. The method was in-house validated and meets all criteria of European legislation (2002/657/EC). The precision of the method was determined under repeatability and within-laboratory reproducibility conditions; RSD(r) and RSD(R) were below the maximum permitted values for every tested concentration. The specificity was checked by analysing representative blank samples and blank samples fortified with potentially interfering substances (benzimidazoles, corticosteroides, triphenylmethane dyes, quinolones, nitrofurans, nitroimidazoles, phenicols); no interference were found. Concerning quantification, a quadratic regression model was fitted to every calibration curve with a regression coefficient r2 above 0.99 on each data set. Finally, the expanded uncertainty U was calculated with data obtained within the laboratory while applying the method during validation and in routine tests.

  18. Experimental study on new monitoring method of radon release rate from uranium tailings

    CERN Document Server

    Fu Jin; HanYaozHao; He Wen Xing; Zhang Biao

    2002-01-01

    Two new monitoring methods of radon release rate from uranium tailings are introduced. They are the active carbon absorption and gamma energy spectrum method. The instrument and sampler of active carbon absorption is presented with the manufacture, function, performance and calibration, the conditional test of the method and its measuring contrast to that of local static method. One-year continuous in-site monitoring of radon release rate of uranium tailings was done. The annual change regularity of radon release rate from uranium tailings was observed. The optimum season and condition of monitoring the annual average radon release rate are summarized. The parameter monitoring, calculating method and experimentation of gamma energy spectrum method is discussed

  19. Evaluation of SW846 Method 8330 for Characterization of Sites Contaminated with Residues of High Explosives

    Science.gov (United States)

    1993-06-01

    the transformation pathways of some explosives have Method 8330 is the sum of the TNB and TNBA initially been studied in cell cultures , composting...soil. Talanta, 39:419-428. products in soils and plant tissues by high-performance Jenkins, T.F., P.H. Miyares, K.F. Myers, E.F. McCor- liquid... hydroponic plants. Environmental Toxicology and (1976)Aquaticfield survey at Iowa, Radford, and Joliet Chemistry, 10: 845-855. Armn Ammunition Plants

  20. Evaluating The Methods For Postvoiding Residual Volume Assesment And Factors That May Influence The Results

    Directory of Open Access Journals (Sweden)

    Unal Bicakci

    2017-12-01

    Conclusion: Measurement of PVR by portable ultrasonography yields comparable results with urethral catheterization. Although PVR measurement on VCUG images is a less reliable method, it can provide additional information in certain conditions (ie. VUR, diverticulum... Although statistical significance could not be demonstrated, we believe that VUR, renal scaring and bladder trabeculation may interfere with the results of PVR assessments. [J Contemp Med 2017; 7(4.000: 329-332

  1. Study on the residual stress relaxation in girth-welded steel pipes under bending load using diffraction methods

    International Nuclear Information System (INIS)

    Hempel, Nico; Nitschke-Pagel, Thomas; Dilger, Klaus

    2017-01-01

    This research is dedicated to the experimental investigation of the residual stress relaxation in girth-welded pipes due to quasi-static bending loads. Ferritic-pearlitic steel pipes are welded with two passes, resulting in a characteristic residual stress state with high tensile residual stresses at the weld root. Also, four-point bending is applied to generate axial load stress causing changes in the residual stress state. These are determined both on the outer and inner surfaces of the pipes, as well as in the pipe wall, using X-ray and neutron diffraction. Focusing on the effect of tensile load stress, it is revealed that not only the tensile residual stresses are reduced due to exceeding the yield stress, but also the compressive residual stresses for equilibrium reasons. Furthermore, residual stress relaxation occurs both parallel and perpendicular to the applied load stress.

  2. Nuclear and thermal power plant components monitoring by pattern recognition methods

    International Nuclear Information System (INIS)

    Chehade, M.

    1981-05-01

    This study deals with the monitoring of complex systems with the aim of diagnosing failures or degradation of operation. The different monitoring and diagnostic techniques are reviewed and a statistical analyses of data is presented. The hardware and software for the acquisition and processing of data are presented. The method of monitoring is applied to the extraction valve and the pressurizer discharge isolation valve surveillance [fr

  3. External individual monitoring: experiments and simulations using Monte Carlo Method

    International Nuclear Information System (INIS)

    Guimaraes, Carla da Costa

    2005-01-01

    In this work, we have evaluated the possibility of applying the Monte Carlo simulation technique in photon dosimetry of external individual monitoring. The GEANT4 toolkit was employed to simulate experiments with radiation monitors containing TLD-100 and CaF 2 :NaCl thermoluminescent detectors. As a first step, X ray spectra were generated impinging electrons on a tungsten target. Then, the produced photon beam was filtered in a beryllium window and additional filters to obtain the radiation with desired qualities. This procedure, used to simulate radiation fields produced by a X ray tube, was validated by comparing characteristics such as half value layer, which was also experimentally measured, mean photon energy and the spectral resolution of simulated spectra with that of reference spectra established by international standards. In the construction of thermoluminescent dosimeter, two approaches for improvements have. been introduced. The first one was the inclusion of 6% of air in the composition of the CaF 2 :NaCl detector due to the difference between measured and calculated values of its density. Also, comparison between simulated and experimental results showed that the self-attenuation of emitted light in the readout process of the fluorite dosimeter must be taken into account. Then, in the second approach, the light attenuation coefficient of CaF 2 :NaCl compound estimated by simulation to be 2,20(25) mm -1 was introduced. Conversion coefficients C p from air kerma to personal dose equivalent were calculated using a slab water phantom with polymethyl-metacrilate (PMMA) walls, for reference narrow and wide X ray spectrum series [ISO 4037-1], and also for the wide spectra implanted and used in routine at Laboratorio de Dosimetria. Simulations of backscattered radiations by PMMA slab water phantom and slab phantom of ICRU tissue-equivalent material produced very similar results. Therefore, the PMMA slab water phantom that can be easily constructed with low

  4. Indirect [3H]methyl exchange as a general method for labeling methionine residues: application to calcitonin.

    Science.gov (United States)

    Barling, P M; Preston, J R; Bibby, N J; Wilson, T

    1985-02-01

    Native porcine calcitonin from Armour is known to contain two components. It is shown that these can be separated by cation-exchange chromatography in 8 M urea. The technique of [3H]methyl exchange on the methionine residue was used to prepare each of these in a tritiated form. The reduced components formed by demethylation were found to readily reoxidize at neutral pH, to regenerate the disulfide bridge. Evidence is provided to show that the two forms were partially interconverted during these steps. The reoxidized 3H-labeled products were found to be indistinguishable in chemical, immunological, and biological properties from the equivalent components in native porcine calcitonin and had specific activities of approximately 20 Ci/mmol. It is concluded that this labeling method can be conveniently applied to peptides containing one or more disulfide bridges, to give products of high specific activity in acceptable yield, provided appropriate conditions are used to ensure correct reoxidation occurs.

  5. Use of mass spectrometry methods as a strategy for detection and determination of residual solvents in pharmaceutical products.

    Science.gov (United States)

    Pérez Pavón, José Luis; del Nogal Sanchez, Miguel; García Pinto, Carmelo; Fernandez Laespada, M Esther; Moreno Cordero, Bernardo

    2006-07-15

    In the present work a strategy for the qualitative and quantitative analysis of residual solvents in pharmaceutical products is reported. First, a low-resolution chromatogram is generated for the identification of the solvents present in the samples by means of headspace generation-fast gas chromatography-mass spectrometry (HS-fast GC/MS). From the plotting of this information by means of contour plots with time and mass/charge axes, it is decided whether quantification of such compounds can be accomplished without chromatographic separation or whether it should be done by fast gas chromatography. The nonseparative method is based on direct coupling of a headspace sampler with a mass spectrometer (HS-MS) and requires a signal recording time of only 3 min, while with fast gas chromatography the time required to obtain a chromatogram is 7.16 min. The use of headspace generation for introducing the sample and standard addition as a quantification technique provided satisfactory results and minimized the matrix effect. An important advantage of the methodologies used here is related to the fact that no prior treatment of the sample is required, thus minimizing the creation of analytical artifacts and the errors associated with this step of the analytical process. The methods were applied to the determination of residual solvents in 27 different pharmaceutical products. Detection and quantitation limits were sufficiently low to enable the estimation of organic volatile impurities according to the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use.

  6. Energy dependent mesh adaptivity of discontinuous isogeometric discrete ordinate methods with dual weighted residual error estimators

    Science.gov (United States)

    Owens, A. R.; Kópházi, J.; Welch, J. A.; Eaton, M. D.

    2017-04-01

    In this paper a hanging-node, discontinuous Galerkin, isogeometric discretisation of the multigroup, discrete ordinates (SN) equations is presented in which each energy group has its own mesh. The equations are discretised using Non-Uniform Rational B-Splines (NURBS), which allows the coarsest mesh to exactly represent the geometry for a wide range of engineering problems of interest; this would not be the case using straight-sided finite elements. Information is transferred between meshes via the construction of a supermesh. This is a non-trivial task for two arbitrary meshes, but is significantly simplified here by deriving every mesh from a common coarsest initial mesh. In order to take full advantage of this flexible discretisation, goal-based error estimators are derived for the multigroup, discrete ordinates equations with both fixed (extraneous) and fission sources, and these estimators are used to drive an adaptive mesh refinement (AMR) procedure. The method is applied to a variety of test cases for both fixed and fission source problems. The error estimators are found to be extremely accurate for linear NURBS discretisations, with degraded performance for quadratic discretisations owing to a reduction in relative accuracy of the "exact" adjoint solution required to calculate the estimators. Nevertheless, the method seems to produce optimal meshes in the AMR process for both linear and quadratic discretisations, and is ≈×100 more accurate than uniform refinement for the same amount of computational effort for a 67 group deep penetration shielding problem.

  7. A review of hemodynamic monitoring techniques, methods and devices for the emergency physician.

    Science.gov (United States)

    Laher, Abdullah E; Watermeyer, Matthew J; Buchanan, Sean K; Dippenaar, Nicole; Simo, Nelly Clotilde Tchouambou; Motara, Feroza; Moolla, Muhammed

    2017-09-01

    The emergency department (ED) is frequently the doorway to the intensive care unit (ICU) for a significant number of critically ill patients presenting to the hospital. Hemodynamic monitoring (HDM) which is a key component in the effective management of the critically ill patient presenting to the ED, is primarily concerned with assessing the performance of the cardiovascular system and determining the correct therapeutic intervention to optimise end-organ oxygen delivery. The spectrum of hemodynamic monitoring ranges from simple clinical assessment and routine bedside monitoring to point of care ultrasonography and various invasive monitoring devices. The clinician must be aware of the range of available techniques, methods, interventions and technological advances as well as possess a sound approach to basic hemodynamic monitoring prior to selecting the optimal modality. This article comprises an in depth discussion of an approach to hemodynamic monitoring techniques and principles as well as methods of predicting fluid responsiveness as it applies to the ED clinician. We review the role, applicability and validity of various methods and techniques that include; clinical assessment, passive leg raising, blood pressure, finger based monitoring devices, the mini-fluid challenge, the end-expiratory occlusion test, central venous pressure monitoring, the pulmonary artery catheter, ultrasonography, bioreactance and other modern invasive hemodynamic monitoring devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Optimization of a method by liquid chromatography of high resolution to determine residues of ethilenthiourea in samples of tomato

    International Nuclear Information System (INIS)

    Mora, D.; Rodriguez, O.M.

    2002-01-01

    A method was optimized to determine the present residues of ethilenthiourea in samples of tomatoes. The method consisted of three stages: a extraction of ultrasonic bath with methanol; a cleaning of the extract through a glass column of 11 mm of diameter stuffed with 2,5 g of neutral aluminium's mixture and activated coal (97,5:2,5) and 2,5 g of pure-neutral aluminium, it is dissolved with 250 ml of methanol. The third stage was of quantification by HPLC in a C 18 ' column with a methanol and water mixture (90:10) like a mobile phase to an flow of 2,0 ml/min. and with UV detection to 232 nm. The retention's time under theses conditions was of 2,15 minutes. The merit's parameters of the method were determined, proving and lineal sphere between 1,0 and 28,0 (g/ml of ETU; some quantification and detection limits have been calculated by the method of Hubaux and Vos (22) of 0,153 and 0,306 mg/ml respectively and a recuperation of 84%. (Author) [es

  9. Monitoring of organochlorine and organophosphorus pesticide residues in water during different seasons of Tighra reservoir Gwalior, Madhya Pradesh, India.

    Science.gov (United States)

    Mamta; Rao, R J; Wani, Khursheed Ahmad

    2015-11-01

    Analysis of pesticides during different seasons for pesticidal contamination in water samples of Tighra reservoir was carried out on gas chromatograph-electron capture detector with capillary columns following multiresidual analytical technique. Organochlorine pesticides, viz., hexachlorobenzene (HCB), alpha-benzene hexachloride (BHC), beta-BHC, γ-BHC, heptachlor, aldrin, alpha-endosulfan, beta-endosulfan, p,p-DDE, dieldrin, o,p-dichlorodiphenyldichloroethane (DDD), p,p-DDD, p,p-dichlorodiphenyltrichloroethane (DDT), and endrin, and organophosphorus pesticides, viz., choloropyrifos, methyl parathion, diazion, dicholorovos, ethion, malathion, and parathion, were detected in water samples during different seasons. However, the pesticide concentration varied during different seasons at different sites. The prominent reason of contamination is the use of pesticides (both organochlorine and organophosphorus) in the agricultural fields near Tighra reservoir. On the basis of our observations, more extensive monitoring studies need to be carried out, covering all wetlands of Madhya Pradesh to enforce the policies for the restricted application of pesticides in agricultural fields adjacent to wetlands.

  10. Method for detecting, screening and/or monitoring a cancer in an individual

    DEFF Research Database (Denmark)

    2003-01-01

    The invention relates to a method for screening and/or detecting and/or monitoring a cancer in an individual, said method comprising determining a first parameter represented by the concentration of TIMP-1 in at least one excreta, e.g. saliva, from the individual. The invention provides a method...... that without the need to use a blood sample is suitable for facilitating the early diagnosis of a cancer, monitoring the recurrence of a cancer, and/or monitoring the status of a cancer or the effect of cancer treatment in an individual....

  11. Real-time earthquake monitoring using a search engine method.

    Science.gov (United States)

    Zhang, Jie; Zhang, Haijiang; Chen, Enhong; Zheng, Yi; Kuang, Wenhuan; Zhang, Xiong

    2014-12-04

    When an earthquake occurs, seismologists want to use recorded seismograms to infer its location, magnitude and source-focal mechanism as quickly as possible. If such information could be determined immediately, timely evacuations and emergency actions could be undertaken to mitigate earthquake damage. Current advanced methods can report the initial location and magnitude of an earthquake within a few seconds, but estimating the source-focal mechanism may require minutes to hours. Here we present an earthquake search engine, similar to a web search engine, that we developed by applying a computer fast search method to a large seismogram database to find waveforms that best fit the input data. Our method is several thousand times faster than an exact search. For an Mw 5.9 earthquake on 8 March 2012 in Xinjiang, China, the search engine can infer the earthquake's parameters in <1 s after receiving the long-period surface wave data.

  12. Digital processing method for monitoring the radioactivity of stack releases

    International Nuclear Information System (INIS)

    Vialettes, H.; Leblanc, P.; Perotin, J.P.; Lazou, J.P.

    1978-01-01

    The digital processing method proposed is adapted for data supplied by a fixed-filter detector normally used for analogue processing (integrator system). On the basis of the raw data (pulses) from the detector, the technique makes it possible to determine the rate of activity released whereas analogue processing gives only the released activity. Furthermore, the method can be used to develop alarm systems on the basis of a possible exposure rate at the point of fall-out, and by including in the program a coefficient which allows for atmospheric diffusion conditions at any given time one can improve the accuracy of the results. In order to test the digital processing method and demonstrate its advantages over analogue processing, various atmospheric contamination situations were simulated in a glove-box and analysed simultaneously, using both systems, from the pulses transmitted by the same sampling and fixed-filter detection unit. The experimental results confirm the advantages foreseen in the theoretical research. (author)

  13. Grouping of residual solvents present in pharmaceuticals using experimental planning and chemometric methods.

    Science.gov (United States)

    Grodowska, Katarzyna; Parczewski, Andrzej

    2013-01-01

    The main effects of six experimental factors on the efficiency of HS (headspace) extraction in headspace gas chromatography--flame ionization detector (HS-GC-FID) determination of twenty organic solvents routinely used in production of pharmaceuticals were obtained on the basis of the results of experiments carried out according to the Plackett-Burman factorial design. The effects were used as a basis for grouping the solvents into five groups, the solvents belonging to a group responded similarly to changes of HS conditions. To this end, visualization approaches were used as well as chemometric methods: cluster analysis (CA) and principal component analysis (PCA). Moreover, the most important HS experimental factors were selected for further optimization of the HS-GC determination procedure.

  14. Matrix Effect Evaluation and Method Validation of Azoxystrobin and Difenoconazole Residues in Red Flesh Dragon Fruit (Hylocereus polyrhizus) Matrices Using QuEChERS Sample Preparation Methods Followed by LC-MS/MS Determination.

    Science.gov (United States)

    Noegrohati, Sri; Hernadi, Elan; Asviastuti, Syanti

    2018-03-30

    Production of red flesh dragon fruit (Hylocereus polyrhizus) was hampered by Colletotrichum sp. Pre-harvest application of azoxystrobin and difenoconazole mixture is recommended, therefore, a selective and sensitive multi residues analytical method is required in monitoring and evaluating the commodity's safety. LC-MS/MS is a well-established analytical technique for qualitative and quantitative determination in complex matrices. However, this method is hurdled by co-eluted coextractives interferences. This work evaluated the pH effect of acetate buffered and citrate buffered QuEChERS sample preparation in their effectiveness of matrix effect reduction. Citrate buffered QuEChERS proved to produce clean final extract with relative matrix effect 0.4%-0.7%. Method validation of the selected sample preparation followed by LC-MS/MS for whole dragon fruit, flesh and peel matrices fortified at 0.005, 0.01, 0.1 and 1 g/g showed recoveries 75%-119%, intermediate repeatability 2%-14%. The expanded uncertainties were 7%-48%. Based on the international acceptance criteria, this method is valid.

  15. Natural sex steroids and their xenobiotic analogs in animal production: growth, carcass quality, pharmacokinetics, metabolism, mode of action, residues, methods, and epidemiology.

    Science.gov (United States)

    Lone, K P

    1997-03-01

    Natural and xenobiotic compounds having sex-related actions have long been used for growth promotion and various changes in carcass quality in meat animals. The first compounds used were synthetic estrogens; however, later on a whole battery of compounds having androgenic, and progestogenic actions have also been involved. In surveying the effects of these compounds in meat-producing animals, it became clear that these drugs increase the growth rate of the treated animals and bring about changes in the carcass that are generally characterized by lower fat content and more lean mass. Extensive studies undertaken in various countries, including the European Economic Community (EEC), have shown that if used according to good husbandry practices, the meat from treated animals does not have excessive amounts of residues compared with the endogenous amount of steroid production in the animals in question and also in human beings. The banning of these compounds in the European community brought a new phenomenon of illegal or black market cocktails. These mixtures of anabolic steroids are injected into the body of the animals rather than implanted in the ears, which is the normal practice in countries where they have not yet been banned. Several screening and confirmatory methods are now available for monitoring programs. However, these programs need excessive resources in terms of manpower, funds, and proper legislation, which in underdeveloped countries is questionable, particularly in the absence of strong scientific evidence for the exercise.

  16. Development of an online monitoring method of a CO2 capture process

    NARCIS (Netherlands)

    Geers, L.F.G.; Runstraat, A. van de; Joh, R.; Schneider, R.; Goetheer, E.L.V.

    2011-01-01

    One possible way to reduce our carbon footprint is using postcombustion capture (PCC) processes to remove CO2 from flue gases. Because of the highly dynamic characteristics of such processes, real-time performance monitoring is a very complex task. This paper presents a method for monitoring the

  17. Possibility of improvement of potentiodynamic method for monitoring ...

    Indian Academy of Sciences (India)

    Quantitative data on corroding steel reinforcement in reinforced concrete structures are undoubtedly very useful for evaluation of their service life and timely repairs. The method of electrode potential measurement is a convenient and simple test for this purpose, but it provides no quantitative data on corrosion rate and only ...

  18. Possibility of improvement of potentiodynamic method for monitoring ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Quantitative data on corroding steel reinforcement in reinforced concrete structures are undoubtedly very useful for evaluation of their service life and timely repairs. The method of electrode potential measure- ment is a convenient and simple test for this purpose, but it provides no quantitative data on corrosion rate ...

  19. Method and apparatus to monitor a beam of ionizing radiation

    Science.gov (United States)

    Blackburn, Brandon W.; Chichester, David L.; Watson, Scott M.; Johnson, James T.; Kinlaw, Mathew T.

    2015-06-02

    Methods and apparatus to capture images of fluorescence generated by ionizing radiation and determine a position of a beam of ionizing radiation generating the fluorescence from the captured images. In one embodiment, the fluorescence is the result of ionization and recombination of nitrogen in air.

  20. Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review

    Science.gov (United States)

    Bera, Tushar Kanti

    2014-01-01

    Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932