WorldWideScience

Sample records for residue analytical methods

  1. Analytical Methods for Detonation Residues of Insensitive Munitions

    Science.gov (United States)

    Walsh, Marianne E.

    2016-01-01

    Analytical methods are described for the analysis of post-detonation residues from insensitive munitions. Standard methods were verified or modified to obtain the mass of residues deposited per round. In addition, a rapid chromatographic separation was developed and used to measure the mass of NTO (3-nitro-1,2,4-triazol-5-one), NQ (nitroguanidine) and DNAN (2,4-dinitroanisole). The HILIC (hydrophilic-interaction chromatography) separation described here uses a trifunctionally-bonded amide phase to retain the polar analytes. The eluent is 75/25 v/v acetonitrile/water acidified with acetic acid, which is also suitable for LC/MS applications. Analytical runtime was three minutes. Solid phase extraction and LC/MS conditions are also described.

  2. Moxidectin residues in lamb tissues: Development and validation of analytical method by UHPLC-MS/MS.

    Science.gov (United States)

    Del Bianchi A Cruz, Michelle; Fernandes, Maria A M; de C Braga, Patricia A; Monteiro, Alda L G; Daniel, Daniela; Reyes, Felix G R

    2018-01-01

    The development and validation of a throughput method for the quantitation of moxidectin residues in lamb target tissues (muscle, kidney, liver and fat) was conducted using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). To achieve higher recovery of the analyte from the matrices, a modified QuEChERS method was used for sample preparation. The chromatographic separation was achieved using a Zorbax Eclipse Plus C18 RRHD column with a mobile phase comprising 5mM ammonium formate solution +0.1% formic acid (A) and acetonitrile +0.1% formic acid (B) in a linear gradient program. Method validation was performed based on the Commission Decision 2002/657/EC and VICH GL49. To quantify the analyte, matrix-matched analytical curves were constructed with spiked blank tissues, with a limit of quantitation of 5ngg -1 and limit of detection of 1.5ngg -1 for all matrices. The linearity, decision limit, detection capability accuracy, and inter- and intra-day repeatability of the method are reported. The method was successfully applied to incurred lamb tissue samples (muscle, liver, kidney and fat) in a concentration range from 5 to 200μgkg -1 , which demonstrated its suitability for monitoring moxidectin residues in lamb tissues in health surveillance programs, as well as for pharmacokinetics and residue depletion studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Evaluation of Antibiotic Residues in Raw Meat Using Different Analytical Methods.

    Science.gov (United States)

    Ramatla, Tsepo; Ngoma, Lubanza; Adetunji, Modupeade; Mwanza, Mulunda

    2017-12-07

    Antibiotic residue in meat is a serious public health concern due to its harmful effects on consumer health. This study aimed at estimating the residue levels of four commonly used antibiotics in meat samples using three analytical methods (ELISA, TLC and HPLC). A total of 150 samples of raw meat from sales points were analysed for ciprofloxacin, streptomycin, tetracycline, and sulphanilamide residues. Overall, ELISA analysis showed that 56, 34, 18, and 25.3% of the samples tested positive for ciprofloxacin, streptomycin, sulphanilamide and tetracycline residues respectively while TLC and HPLC detected 21.4, 29.4, 92.5, and 14.6%, and 8.3, 41.1, 88.8, and 14.6% of the samples as containing the residues, with ciprofloxacin and sulphanilamide having the lowest and highest occurrence, respectively. Furthermore, the concentrations of antibiotic residues were in the ranges of 19.8-92.8, 26.6-489.1, 14.2-1280.8, and 42.6-355.6 μg/kg with ELISA, while HPLC detected concentration ranges of 20.7-82.1, 41.8-320.8, 65.2-952.2 and 32.8-95.6 μg/kg for sulphanilamide, tetracycline, streptomycin, and ciprofloxacin, respectively. Mean ciprofloxacin and streptomycin residue levels were above the Codex/SA MRL recommended limit, while 3% of the samples contained multidrug residues. Although some of the mean residues levels were below the permissible limits, the co-occurrence of multidrug residues in some of the samples calls for concern.

  4. Zeranol: a review of the metabolism, toxicology, and analytical methods for detection of tissue residues

    International Nuclear Information System (INIS)

    Baldwin, R.S.; Williams, R.D.; Terry, M.K.

    1983-01-01

    Zeranol, an anabolic agent produced commercially for use in cattle and sheep intended for human consumption, is noncarcinogenic, nonteratogenic, and nonmutagenic. Toxicity testing (acute, subacute, and chronic) in several species by various routes of administration reveals an extremely low toxicity, the oral rat LD 50 exceeding 40 g/kg. Postmortem abnormalities of high-dose animals are attributed to the effects of the compound on the endocrine system. Both zeranol itself and zearalanone, the major Phase I metabolite in the seven species studied, are excreted in the feces and in the urine, either free or as sulfates/glucuronides. A minor urinary metabolite has been identified as taleranol, an epimer of zeranol. Both metabolites exhibit a very low order of toxicity (oral rat LD 50 exceeding 10 g/kg in both cases), and both exhibit less biological activity than the parent compound. The four types of analytical methods which have been employed for the specific detection and quantitation of residues of zeranol in edible tissues are: (1) gas chromatography (detection limit . 20 ppb), (2) high-performance liquid chromatography (detection limit . 5 ppb), (3) thin-layer chromatography (detection limit . 1-3 ppb), and (4) radioimmunoassay methods (detection limit to be published). The following residue levels were determined radiometrically in tissue samples taken 45 days after implantation of cattle with 36 mg tritiated zeranol: less than or equal to 2 ppb in liver, less than or equal to 1 ppb in kidney and fat, and less than or equal to 0.2 ppb in muscle and plasma. A no-effect level (NEL) of 0.225 mg/kg was determined as the highest oral dosage of zeranol which produced no estrogenic effects in female monkeys. Based on the NEL, a tolerance level for tissue residues of zeranol was calculated as 315 ppb

  5. [Development of analytical methods for residual N-methyl carbamate pesticides in foods].

    Science.gov (United States)

    Goto, Tomomi

    2010-08-01

    One of the major roles of public health agencies is to ensure safe products for consumers through analysis of residual agricultural chemicals and veterinary drugs in foods. The use of agricultural chemicals and veterinary drugs in agriculture is necessary to improve the quality of the food produced. They play a beneficial role in providing a plentiful, low-cost supply of high-quality food. On the other hand, as a consequence of this use, the presence of residues in food that is a critical element of overall public health is unavoidable, and residues in food are of great importance in the evaluation of food quality. N-methyl carbamate pesticides have anticholinesterase activity and are used worldwide. The postcolumn HPLC method is widely used for the detection of N-methyl carbamate pesticides in food. However, this traditional method involves a time-consuming process that requires skillful techniques. Therefore we developed a new analysis method for N-methyl carbamate pesticides as described in detail in this paper. The new method, including sample preparation and determination, is simple and rapid and allows simultaneous determination of pesticides in food within a much shorter analysis time as compared with the traditional method. This should provide high-quality analysis and ensure safe products for consumers.

  6. Development of an analytical method for determination of sulfonamide residues in eggs

    International Nuclear Information System (INIS)

    Ben Azzeddine, Chams

    2009-01-01

    For the determination of sulfonamide residues in eggs, Premitest is selected for screening, providing a qualitative biological approach, it is inexpensive, fast, multi-elements and easy to implement. The H. P.L.C. / UV is the quantitative method of choice for confirmation and determination of these contaminants. During my internship, I had the opportunity to participate in the development of this method. It is recognized slower and more expensive but more specific and more sensitive. In this report, I present this optimized method and some criteria checked during my internship. Other criteria are to be completed to validate the method that will be subsequently used for routine analysis.

  7. Development of Analytical Method for Predicting Residual Mechanical Properties of Corroded Steel Plates

    Directory of Open Access Journals (Sweden)

    J. M. R. S. Appuhamy

    2011-01-01

    Full Text Available Bridge infrastructure maintenance and assurance of adequate safety is of paramount importance in transportation engineering and maintenance management industry. Corrosion causes strength deterioration, leading to impairment of its operation and progressive weakening of the structure. Since the actual corroded surfaces are different from each other, only experimental approach is not enough to estimate the remaining strength of corroded members. However, in modern practices, numerical simulation is being used to replace the time-consuming and expensive experimental work and to comprehend on the lack of knowledge on mechanical behavior, stress distribution, ultimate behavior, and so on. This paper presents the nonlinear FEM analyses results of many corroded steel plates and compares them with their respective tensile coupon tests. Further, the feasibility of establishing an accurate analytical methodology to predict the residual strength capacities of a corroded steel member with lesser number of measuring points is also discussed.

  8. Occurrence of erythromycin residues in sheep milk. Validation of an analytical method.

    Science.gov (United States)

    García-Mayor, M A; Paniagua-González, G; Soledad-Rodríguez, B; Garcinuño-Martínez, R M; Fernández-Hernando, P; Durand-Alegría, J S

    2015-04-01

    The paper describes a new and selective analytical sample treatment for quantitative extraction and preconcentration of erythromycin in presence of other macrolide antibiotics in sheep milk samples. The methodology is based on the use of a molecular imprinted polymer (MIP) employed as solid phase extraction sorbent (MISPE). The synthesized material by bulk polymerization using erythromycin (ERY) as template was evaluated as solid phase extraction sorbent, in a novel sample treatment technique that can be coupled to high-performance liquid chromatography with diode-array detector (HPLC-DAD). MIP selectivity was studied for other macrolide antibiotics with similar structures, such as tylosin (TYL), spiramycin (SPI), josamycin (JOS), roxithromycin (ROX) and ivermectin (IVER) getting recoveries for these interferents lower than 35%, for all cases except for ROX, which recoveries were around 85%. The variables affecting the molecularly imprinted solid-phase extraction (MISPE) procedure were optimized to select the best conditions of selectivity and sensitivity to determine ERY at concentration levels established by EU legislation in sheep milk. Under the selected experimental conditions, quantification limit was 24.1 µg kg(-1). Recoveries were higher than 98%, with RSDs between 0.7% and 2%. The proposed MISPE-HPLC method was validated and successfully applied to ERY analysis in sheep milk samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Development of Analytical Method and Monitoring of Veterinary Drug Residues in Korean Animal Products.

    Science.gov (United States)

    Song, Jae-Sang; Park, Su-Jeong; Choi, Jung-Yun; Kim, Jin-Sook; Kang, Myung-Hee; Choi, Bo-Kyung; Hur, Sun Jin

    2016-01-01

    This study was conducted to determine the residual amount of veterinary drugs such as meloxicam, flunixin, and tulathromycin in animal products (beef, pork, horsemeat, and milk). Veterinary drugs have been widely used in the rearing of livestock to prevent and treat diseases. A total of 152 samples were purchased from markets located in major Korean cities (Seoul, Busan, Incheon, Daegu, Daejeon, Gwangju, Ulsan and Jeju), including Jeju. Veterinary drugs were analyzed by liquid chromatography-tandem mass spectrometry according to the Korean Food Standards Code. The resulting data, which are located within 70-120% of recovery range and less than 20% of relative standard deviations, are in compliance with the criteria of CODEX. A total of five veterinary drugs were detected in 152 samples, giving a detection rate of approximately 3.3%; and no food source violated the guideline values. Our result indicated that most of the veterinary drug residues in animal products were below the maximum residue limits specified in Korea.

  10. Analytical quality assurance in veterinary drug residue analysis methods: matrix effects determination and monitoring for sulfonamides analysis.

    Science.gov (United States)

    Hoff, Rodrigo Barcellos; Rübensam, Gabriel; Jank, Louise; Barreto, Fabiano; Peralba, Maria do Carmo Ruaro; Pizzolato, Tânia Mara; Silvia Díaz-Cruz, M; Barceló, Damià

    2015-01-01

    In residue analysis of veterinary drugs in foodstuff, matrix effects are one of the most critical points. This work present a discuss considering approaches used to estimate, minimize and monitoring matrix effects in bioanalytical methods. Qualitative and quantitative methods for estimation of matrix effects such as post-column infusion, slopes ratios analysis, calibration curves (mathematical and statistical analysis) and control chart monitoring are discussed using real data. Matrix effects varying in a wide range depending of the analyte and the sample preparation method: pressurized liquid extraction for liver samples show matrix effects from 15.5 to 59.2% while a ultrasound-assisted extraction provide values from 21.7 to 64.3%. The matrix influence was also evaluated: for sulfamethazine analysis, losses of signal were varying from -37 to -96% for fish and eggs, respectively. Advantages and drawbacks are also discussed considering a workflow for matrix effects assessment proposed and applied to real data from sulfonamides residues analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Parameter validation of analytical methods of insecticide residue analyses in foods of animal origin, feed and water.

    Science.gov (United States)

    Debebe, Amsalu; Kuttalam, S

    2011-06-01

    The study was conducted to examine the interrelationship and coherence of analytical parameters in method validation. Recovery, sensitivity, linearity, precision and limits of detection (LOD) were tested in six methods for organochlorine and organophosphate insecticides. Compounds that fell out of the stipulated recovery, 70-120%, in a matrix have concurrently failed to meet the requirements for sensitivity (≥ 0.7), linearity (R² > 0.99) and precision (< 0.2) in the same matrix. Highest LOD was recorded in those compounds and matrices. Different from the conventional point estimate, a new approach was introduced for setting upper and lower confidence limits of the LOD in quantitative analyses.

  12. Development of a multi-residue analytical method, based on liquid chromatography-tandem mass spectrometry, for the simultaneous determination of 46 micro-contaminants in aqueous samples.

    Science.gov (United States)

    Nödler, Karsten; Licha, Tobias; Bester, Kai; Sauter, Martin

    2010-10-15

    A multi-residue analytical method based on high-performance liquid chromatographic separation, electrospray ionization with tandem mass spectrometric detection (HPLC/MS-MS) was developed for the simultaneous analysis of 46 basic, neutral and acidic compounds covering a wide range of polarity (logK(OW)MQL) in surface and seawater ranged from 1.2 to 28 ng/L, in wastewater from 5.0 to 160 ng/L, respectively. In order to demonstrate the applicability of the method, river water, treated wastewater and seawater were analyzed. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Identification of improvised explosives residues using physical-chemical analytical methods under real conditions after an explosion

    Science.gov (United States)

    Kotrlý, Marek; Mareš, Bohumil; Turková, Ivana; Beroun, Ivo

    2016-05-01

    Within the analysis of cases relating to the use of explosives for crimes, we have experienced a shift from using industrial explosives towards substances made in amateur and illegal way. Availability of industrial explosives is increasingly limited to a narrow sphere of subjects with a relevant permission. Thus, on the part of perpetrators, terrorists, ever greater attention is paid to illegal production of explosives that are easily made from readily available raw materials. Another alarming fact is the availability of information found on the internet. Procedures of preparation are often very simple and do not require even a deeper professional knowledge. Explosive characteristics are not actually accessible for many of these substances (detonation velocity, sensitivity, working capacity, brisance, physical and chemical stability, etc.). Therefore, a project is being implemented, which on grounds of assessment of individual information available in literature and on the internet, aiming at choosing individual areas of potentially abusable substances (e.g. mixtures of nitric acid (98%) with organic substances, mixtures nitromethane and tetranitromethane with organic substances, mixtures of chlorates and perchlorates of alkali metals with organic substances, chemically individual compounds of organic base type of perchloric acid, azides, fulminates, acetylides, picrates, styphnates of heavy metals, etc.). It is directed towards preparation of these explosives also in non-stoichiometric mixtures, conducting test explosives, determination of explosive characteristics (if they are unknown) and analysis of both primary phases and post-blast residues through available analytical techniques, such as gas and liquid chromatography with mass detection, FTIR, micro-Raman spectrometry, electron microscopy with microanalysis and Raman microspectrometry directly in SEM chamber for analysis at the level of individual microparticles. The received characteristics will be used to

  14. A review of novel strategies of sample preparation for the determination of antibacterial residues in foodstuffs using liquid chromatography-based analytical methods

    International Nuclear Information System (INIS)

    Marazuela, M.D.; Bogialli, S.

    2009-01-01

    The determination of trace residues and contaminants in food has been of growing concern over the past few years. Residual antibacterials in food constitute a risk to human health, especially because they can contribute to the transmission of antibiotic-resistant pathogenic bacteria through the food chain. Therefore, to ensure food safety EU and USA regulatory agencies have established lists of forbidden or banned substances and tolerance levels for authorized veterinary drugs (e.g. antibacterials). In addition, the EU Commission Decision 2002/657/EC has set requirements about the performance of analytical methods for the determination of veterinary drug residues in food and feedstuffs. During the past years, the use of powerful mass spectrometric detectors in combination with innovative chromatographic technologies has solved many problems related to sensitivity and selectivity of this type of analysis. However sample preparation still remains as the bottleneck step, mainly in terms of analysis time and sources of error. This review covering research published between 2004 and 2008 intends to provide an update overview of the past five years, on recent trends in sample preparation for the determination of antibacterial residues in foods, making special emphasis in on-line, high-throughput, multi-class methods and including several applications in detail.

  15. Development of Radiometric and Allied Analytical Methods and Strategies to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues. Final Report of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2016-08-01

    Awareness of food safety is rising among consumers, and many importing countries implement food control regulations to guarantee the quality and safety of imported foods for their consumers. Many developing countries have also taken steps to put in place control systems that encourage responsible use of veterinary medicines to combat possible drug resistance, control drug residues and ensure compliance with international and national standards. However, these countries still require the necessary know-how and skills to protect local consumers and to access international markets. One significant constraint is the capacity of laboratory services to generate surveillance data using reliable and cost effective analytical methods validated to national and international standards. The IAEA coordinated research project (CRP) on the Development of Radiometric and Allied Analytical Methods to Strengthen National Residue Control Programmes for Antibiotic and Anthelmintic Veterinary Drug Residues was initiated in 2009 to conduct work on robust nuclear and related technologies suitable for the screening and confirmatory analysis of residues of veterinary medicines, including antimicrobials and anthelmintics commonly used in animal production, with public health and trade significance. The CRP also explored mechanisms to enhance networking among research institutions involved in research on pharmacologically active veterinary drug residues in food (primarily) and environmental samples. The project was implemented by the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture between 2009 and 2014 and involved eleven research contracts and one technical contract, five research agreements and one institution. The CRP was a continuation of the CRP on the Development of Strategies for the Effective Monitoring of Veterinary Drug Residues in Livestock and Livestock Products in Developing Countries and the key findings are also summarized in this publication.

  16. Analytical method for the determination of cyromazine and melamine residues in soil using LC-UV and GC-MSD.

    Science.gov (United States)

    Yokley, R A; Mayer, L C; Rezaaiyan, R; Manuli, M E; Cheung, M W

    2000-08-01

    A method is reported for the determination of cyromazine and melamine residues in soil. Soil samples are extracted twice via mechanical shaking, each time with 70% acetonitrile/30% 0.050 M ammomium carbonate for 30 min. An aliquot portion of the pooled extracts is subjected to strong cation exchange (SCX) purification on AG 50W-X4 resin. Final analysis is accomplished using liquid chromatography-ultraviolet (LC-UV) detection at a wavelength of 214 nm. Confirmatory analyses can be performed using gas chromatography-mass selective detection (GC-MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 2.5 ng injected and the limit of quantification (LOQ) is 10 ppb when using LC-UV for the analysis of N-cyclopropyl-1,3,5-triazine-2,4, 6-triamine (cyromazine) and 1,3,5-triazine-2,4,6-triamine (melamine). The LOD is 0.050 ng injected and the LOQ is 10 ppb when using GC-MSD for confirmatory analyses. The mean procedural recoveries were 97 and 95% and the standard deviations were 16 and 11% for cyromazine and melamine, respectively (n = 24), when using LC-UV. The mean procedural recoveries were 107 and 92% and the standard deviations were 9.9 and 16% for cyromazine and melamine, respectively (n = 29), when using GC-MSD. The method validation study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160. The method also passed an Independent Laboratory Validation (ILV) as per U.S. EPA FIFRA Subdivision N.

  17. Development of a multi-residue analytical method for TBBP-A and PBDEs in various biological matrices using unique reduced size sample

    Energy Technology Data Exchange (ETDEWEB)

    Andre, F.; Cariou, R.; Antignac, J.P.; Le Bizec, B. [Ecole Nationale Veterinaire de Nantes (FR). Laboratoire d' Etudes des Residus et Contaminants dans les Aliments (LABERCA); Debrauwer, L.; Zalko, D. [Institut National de Recherches Agronomiques (INRA), 31-Toulouse (France). UMR 1089 Xenobiotiques

    2004-09-15

    The impact of brominated flame retardants on the environment and their potential risk for animal and human health is a present time concern for the scientific community. Numerous studies related to the detection of tetrabromobisphenol A (TBBP-A) and polybrominated diphenylethers (PBDEs) have been developed over the last few years; they were mainly based on GC-ECD, GC-NCI-MS or GC-EI-HRMS, and recently GC-EI-MS/MS. The sample treatment is usually derived from the analytical methods used for dioxins, but recently some authors proposed the utilisation of solid phase extraction (SPE) cartridges. In this study, a new analytical strategy is presented for the multi-residue analysis of TBBP-A and PBDEs from a unique reduced size sample. The main objective of this analytical development is to be applied for background exposure assessment of French population groups to brominated flame retardants, for which, to our knowledge, no data exist. A second objective is to provide an efficient analytical tool to study the transfer of these contaminants through the environment to living organisms, including degradation reactions and metabolic biotransformations.

  18. Rapid analytical method for the determination of pesticide residues in sunflower seeds based on focused microwave-assisted Soxhlet extraction prior to gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Prados-Rosales, R C; Luque García, J L; Luque de Castro, M D

    2003-04-18

    A rapid analytical method for determination of organochlorine pesticide residues in sunflower seeds based on focused microwave-assisted Soxhlet extraction has been developed. The main factors affecting the extraction efficiency--namely microwave power, irradiation time, volume of extractant and number of cycles--were optimized by a two-level factorial fractional design. After extraction, a liquid-liquid extraction and a clean-up step including the use of Florisil macrocolumns were required prior to injection of the extracts into the chromatograph in order to isolate the pesticide residues from the lipid fraction of the original extract. The MS-MS ion preparation mode was selected due to the high sensitivity and selectivity it provides. Seed samples were used collected near a crop subjected to aerial pesticide application. Residues of hexachlorocyclohexane isomers and endosulfan were found in the seeds although they were not subjected to pesticide application, thus showing the spray-drift contamination. The validation of the proposed approach was carried out by comparison with the ISO 659-1988 reference extraction method obtaining similar, or even better efficiencies by the proposed approach.

  19. The validation of an analytical method for sulfentrazone residue determination in soil using liquid chromatography and a comparison of chromatographic sensitivity to millet as a bioindicator species.

    Science.gov (United States)

    de Oliveira, Marcelo Antonio; Pires, Fábio Ribeiro; Ferraço, Mariana; Belo, Alessandra Ferreira

    2014-07-28

    Commonly used herbicides, such as sulfentrazone, pose the risk of soil contamination due to their persistence, bioaccumulation and toxicity. Phytoremediation by green manure species has been tested using biomarkers, but analytical data are now required to confirm the extraction of sulfentrazone from soil. Thus, the present work was carried out to analyze sulfentrazone residues in soil based on liquid chromatography with a comparison of these values to the sensitivity of the bioindicator Pennisetum glaucum. The soil samples were obtained after cultivation of Crotalaria juncea and Canavalia ensiformis at four seeding densities and with three doses of sulfentrazone. The seedlings were collected into pots, at two different depths, after 75 days of phytoremediator sowing and then were used to determine the herbicide persistence in the soil. A bioassay with P. glaucum was carried out in the same pot. High-performance liquid chromatography (HPLC), using UV-diode array detection (HPLC/UV-DAD), was used to determine the herbicide residues. The HPLC determination was optimized and validated according to the parameters of precision, accuracy, linearity, limit of detection and quantification, robustness and specificity. The bioindicator P. glaucum was more sensitive to sulfentrazone than residue determination by HPLC. Changes in sulfentrazone concentration caused by green manure phytoremediation were accurately identified by the bioindicator. However, a true correlation between the size of the species and the analyte content was not identified.

  20. The Validation of an Analytical Method for Sulfentrazone Residue Determination in Soil Using Liquid Chromatography and a Comparison of Chromatographic Sensitivity to Millet as a Bioindicator Species

    Directory of Open Access Journals (Sweden)

    Marcelo Antonio de Oliveira

    2014-07-01

    Full Text Available Commonly used herbicides, such as sulfentrazone, pose the risk of soil contamination due to their persistence, bioaccumulation and toxicity. Phytoremediation by green manure species has been tested using biomarkers, but analytical data are now required to confirm the extraction of sulfentrazone from soil. Thus, the present work was carried out to analyze sulfentrazone residues in soil based on liquid chromatography with a comparison of these values to the sensitivity of the bioindicator Pennisetum glaucum. The soil samples were obtained after cultivation of Crotalaria juncea and Canavalia ensiformis at four seeding densities and with three doses of sulfentrazone. The seedlings were collected into pots, at two different depths, after 75 days of phytoremediator sowing and then were used to determine the herbicide persistence in the soil. A bioassay with P. glaucum was carried out in the same pot. High-performance liquid chromatography (HPLC, using UV-diode array detection (HPLC/UV-DAD, was used to determine the herbicide residues. The HPLC determination was optimized and validated according to the parameters of precision, accuracy, linearity, limit of detection and quantification, robustness and specificity. The bioindicator P. glaucum was more sensitive to sulfentrazone than residue determination by HPLC. Changes in sulfentrazone concentration caused by green manure phytoremediation were accurately identified by the bioindicator. However, a true correlation between the size of the species and the analyte content was not identified.

  1. A novel analytical method for the determination of residual moisture in plutonium dioxide: Supercritical fluid extraction/Fourier transform infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, A.M.; Hollis, W.K.; Rubin, J.B.; Taylor, C.M.V.; Jasperson, M.N.; Vance, D.E.; Rodriguez, J.B.

    1999-02-01

    A novel approach has been developed at the Los Alamos National Laboratory for the quantitative determination of moisture content in impure plutonium oxide. The method combines a commercial supercritical fluid extraction instrument using supercritical carbon dioxide (SCCO{sub 2}) with on-line detection using a high-pressure Fourier Transform Infrared Spectroscopy (FTIR) cell. The combined SCCO{sub 2}/FTIR system has been modified for use inside a fully enclosed glove box. A series of validation experiments were performed using a pure, surrogate oxide (ThO{sub 2}) and an inorganic hydrate (CaSO{sub 4}{center_dot}2H{sub 2}O). The level of agreement between LOI and SCCO{sub 2}/FTIR for the surrogate oxide is excellent. The results for the inorganic hydrate showed excellent correlation with the known amount of water present. Results obtained for a group of nominally pure PuO{sub 2} samples were verified by independent measurement. The results of SCCO{sub 2}/FTIR for impure PuO{sub 2} samples is consistently lower than the results of obtained from the current analytical method (Loss On Ignition), indicating that the current method is inadequate for analytical purposes. While further verification experiments of the SCCO{sub 2}/FTIR method are underway, these initial results suggest that SCCO{sub 2}/FTIR could be used as an alternative analytical method for the Materials Identification and Surveillance program.

  2. Analytical and Experimental Study of Residual Stresses in CFRP

    Directory of Open Access Journals (Sweden)

    Chia-Chin Chiang

    2013-01-01

    Full Text Available Fiber Bragg Grating sensors (FBGs have been utilized in various engineering and photoelectric fields because of their good environment tolerance. In this research, residual stresses of carbon fiber reinforced polymer composites (CFRP were studied using both experimental and analytical approach. The FBGs were embedded inside middle layers of CFRP to study the formation of residual stress during curing process. Finite element analysis was performed using ABAQUS software to simulate the CFRP curing process. Both experimental and simulation results showed that the residual stress appeared during cooling process and the residual stresses could be released when the CFRP was machined to a different shape.

  3. Improvement and extension to new analytes of a multi-residue method for the determination of pesticides in cereals and dry animal feed using gas chromatography-tandem quadrupole mass spectrometry revisited.

    Science.gov (United States)

    Walorczyk, Stanisław; Drożdżyński, Dariusz

    2012-08-17

    This article describes a substantially improved multi-residue method for the determination of a large number of pesticides in cereal samples (wheat, rye, barley, oats, maze, buckwheat etc.) and various animal feeds. The sample preparation method and the GC-MS/MS acquisition method were modified to accommodate new complex cereal and feed matrices and to extend the existing analytical scope to 167 pesticides. The co-extractives were reduced by the joint use of primary secondary amine (PSA) and octadecyl (C18), 75 mg and 50 mg/1 mL of acetonitrile extract, in the presence of MgSO(4), and thus the optimal recovery and analytical selectivity were obtained simultaneously. The new cleanup procedure was faster and easier to handle than our previously applied cleanup procedure. The overall recoveries of the pesticides from buckwheat and rye at the three spiking levels of 0.01, 0.05 and 0.25 mg kg(-1) were 96 ± 9% with relative standard deviations of 10 ± 4% on average. At the lowest spiking level of 0.01 mg kg(-1), 137 of 167 pesticide residues (82%) fulfilled the validation criteria with recoveries in the range of 70-120% and RSDs less or equal 20% whereas in the previous approach it was 93 out of 140 analytes (66%). The developed method was implemented in a routine analysis of approximately 900 real samples, providing an increased scope of the analysis, improved analytical performance parameters and improved ruggedness versus the previous approach. A total of 17% analyzed samples contained pesticide residues. There were 24 different compounds encountered in the samples, of which pirimiphos-methyl, tebuconazole, deltamethrin, and chlorpyrifos-methyl were the most frequent ones. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. A rapid SPE-based analytical method for UPLC/MS/MS determination of aminoglycoside antibiotic residues in bovine milk, muscle, and kidney.

    Science.gov (United States)

    Young, Michael S; van Tran, Kim; Goh, Evelyn; Shia, Jeremy C

    2014-01-01

    An SPE-based cleanup protocol was developed for ultra-performance LC (UPLC)/MS/MS determination of residues of the common aminoglycoside antibiotics streptomycin, dihydrostreptomycin, neomycin, and gentamicin in bovine milk, kidney, and muscle. Recoveries for all compounds except neomycin ranged from 80 to 104% for all matrixes studied; recoveries for neomycin ranged from 71 to 84%. Intraday and interday precision data were under 15% for all sample matrixes. Compared with other recently reported cleanup methods, less sample is required, the use of potentially dangerous reagents is minimized, and fewer manipulations are required by the analyst. A high throughput 96-well plate format was used for SPE cleanup and UPLC/MS analysis.

  5. Determination of Anthracycline Drug Residual in Cleaning Validation Swabs of Stainless-Steel Equipment after Production of Cytostatic Injections Using HPLC Analytical Method

    Directory of Open Access Journals (Sweden)

    Zuzana Slivová

    2015-01-01

    Full Text Available Standard cleaning procedures of production line equipment were verified after manufacture of cytostatic injections containing Anthracycline derivate substance. Residual content of Anthracycline drug substance on stainless-steel equipment surface was determined using swab sampling with a specific HPLC-DAD analysis. The acceptance limit was decided as 200.0 μg/100 cm2. Recovery from the stainless-steel surface was 90.1%. Linearity of the method was observed in the concentration range of 0.155–194 μg/mL when estimated using Zorbax TMS (5 μm, 0.25 m × 4.6 mm ID column at 1.3 mL/min flow rate and 254 nm (DAD 190–600 nm. The mobile phase consisted of lauryl hydrogen sulphate solution (3.7 g/L : methanol : acetonitrile (54 : 16 : 30, v/v/v with pH adjusted to 2.5 using phosphoric acid (85%. The LOD and LOQ for Anthracycline derivate were found to be 0.047 and 0.155 μg/mL, respectively. The method validation confirmed the method provides acceptable degree of selectivity, linearity, accuracy, and precision for the intended purposes.

  6. A comparison of direct and indirect analytical methods of computing ...

    African Journals Online (AJOL)

    The first step in the analysis of gravity anomalies for mineral exploration is the extraction of residual gravity anomalies from the observed gravity anomalies. This can be achieved by graphical or analytical methods. Generally, direct and indirect analytical methods are considered better than graphical methods. Telford et al ...

  7. The Cauchy method of residues

    CERN Document Server

    Mitrinović, Dragoslav S

    1993-01-01

    Volume 1, i. e. the monograph The Cauchy Method of Residues - Theory and Applications published by D. Reidel Publishing Company in 1984 is the only book that covers all known applications of the calculus of residues. They range from the theory of equations, theory of numbers, matrix analysis, evaluation of real definite integrals, summation of finite and infinite series, expansions of functions into infinite series and products, ordinary and partial differential equations, mathematical and theoretical physics, to the calculus of finite differences and difference equations. The appearance of Volume 1 was acknowledged by the mathematical community. Favourable reviews and many private communications encouraged the authors to continue their work, the result being the present book, Volume 2, a sequel to Volume 1. We mention that Volume 1 is a revised, extended and updated translation of the book Cauchyjev raeun ostataka sa primenama published in Serbian by Nau~na knjiga, Belgrade in 1978, whereas the greater part ...

  8. Development of a multi-residue method for the determination of pesticides in cereals and dry animal feed using gas chromatography-tandem quadrupole mass spectrometry II. Improvement and extension to new analytes.

    Science.gov (United States)

    Walorczyk, Stanisław

    2008-10-24

    This paper describes the extension and re-validation of a previously published multi-residue method to currently 140 pesticides and 4 pesticide degradation products in cereals and feedingstuffs. The pesticides were extracted using buffered QuEChERS ("quick, easy, cheap, rugged, effective and safe") method and then cleaned up using dispersive solid-phase extraction with Bondesil PSA and C18 sorbents, and optionally by a freezing-out clean-up step. The final extracts were analyzed in a single injection gas chromatographic-tandem quadrupole mass spectrometric (GC-MS/MS) acquisition method. A high degree of confidence was achieved by entering two multiple reaction monitoring transitions per compound. In this way, quantification of analytical results and unequivocal identification of pesticide residues in compliance with the recent European Union criteria could be done in a single analysis. Thorough optimization of the GC-MS/MS acquisition conditions and application of an effective clean-up procedure has resulted in a remarkable enhancement of the validation parameters. The linearity of the calibration curves was excellent in matrix-matched standards, and yielded the coefficients of determination (R(2))> or =0.99 for approximately 96% of the target analytes. Average recoveries of the pesticides spiked at 0.01mgkg(-1) into a feed mixture and wheat grain were in the range 70-120% with associated RSD values feed mixtures and other samples such as malt, starch and dry vegetables have been analyzed. A total of 15 different pesticides have been detected, among which pirimiphos methyl (19 cases), deltamethrin (14 cases), tolylfluanid (5 cases), dichlofluanid (5 cases), and tebuconazole (4 cases) were the most frequently encountered ones.

  9. Analytical methods under emergency conditions

    International Nuclear Information System (INIS)

    Sedlet, J.

    1983-01-01

    This lecture discusses methods for the radiochemical determination of internal contamination of the body under emergency conditions, here defined as a situation in which results on internal radioactive contamination are needed quickly. The purpose of speed is to determine the necessity for medical treatment to increase the natural elimination rate. Analytical methods discussed include whole-body counting, organ counting, wound monitoring, and excreta analysis. 12 references

  10. Decision analytic methods in RODOS

    International Nuclear Information System (INIS)

    Borzenko, V.; French, S.

    1996-01-01

    In the event of a nuclear accident, RODOS seeks to provide decision support at all levels ranging from the largely descriptive to providing a detailed evaluation of the benefits and disadvantages of various countermeasure strategies and ranking them according to the societal preferences as perceived by the decision makers. To achieve this, it must draw upon several decision analytic methods and bring them together in a coherent manner so that the guidance offered to decision makers is consistent from one stage of an accident to the next. The methods used draw upon multi-attribute value and utility theories

  11. Analytical investigation of selected pesticide residues from fruits and ...

    African Journals Online (AJOL)

    Pesticide residues like chlorpyrifos, cypermethrin, deltamethrin and dichlorvos were monitored by an improved extraction method from apple, peach and potato using reverse phase high performance liquid chromatography. The selected pesticides were extracted from fruits and vegetable samples using smaller volume of ...

  12. Rapid multi-residue method for the determination of pesticide ...

    African Journals Online (AJOL)

    Exposure to pesticides can represent a potential risk to humans. Agricultural workers are at risk of chronic toxicity. Hence, the evaluation of pesticide residues in their blood gives an indication about the extent of exposure and help in assessing adverse health effects. The aim of our study was to develop analytical method for ...

  13. Analytical methods used at model facility

    International Nuclear Information System (INIS)

    Wing, N.S.

    1984-01-01

    A description of analytical methods used at the model LEU Fuel Fabrication Facility is presented. The methods include gravimetric uranium analysis, isotopic analysis, fluorimetric analysis, and emission spectroscopy

  14. Identification of hardly biodegradable residuals (sulfur- and nitrogen-containing substances) during waste water treatment, including the development of analytical methods; Identifizierung von schwer abbaubaren Reststoffen (stickstoff- und schwefelhaltigen Verbindungen) bei der Abwasserbehandlung, einschliesslich analytischer Methodenentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Moehle, E.; Huber, A.; Metzger, J.W.

    1999-07-01

    Organic residuals in sewage, which are not removed completely by waste water treatment may be relevant in environmental toxicology and may disturb drinking water treatment processes. The organic residuals must be identified before new techniques to eliminate these substances from waste water can be developed and steps can be taken to prevent them from polluting waste waters. In the research project sum parameters of sulfur- and nitrogen-containing substances in municipal waste water were determined. A new method was developed to determine the organic sulfur in compounds absorbed on activated carbon (AOS). The determination of dissolved organic nitrogen (DON) was calculated as the difference between total nitrogen and the sum of NH{sub 4}{sup +}-N, NO{sub 3}{sup -}-N and NO{sub 2}{sup -}N. The removal of organic substances from the inorganic matrix was only possible for standard solutions, but not for real samples. More than 60 substances contributing to the sum parameters could be identified with GC-MS and GC-AED, an most of them could be quantified. 30-70% of the sulfur-containing substances detected with GC-AED could be identified. With the GC-MS screening method 21 drugs or drug metabolites could be identified and partly quantified. Hydrophilic organic residuals were identified and quantified with high performance liquid chromatography coupled with UV- and fluorescence detectors and also with a mass detector (ESI-MS-MS). With the methods described only a small percentage of the sum of AOS and DON could be detected, although new materials for the solid phase enrichment and new analytical methods, such as HPLC-MS-MS were used. In order to get information about the degree of elimination (absorption or degradation) of different drugs in a municipal sewage plant, laboratory-scale tests under aerobic conditions were performed. A batch reactor containing drugs in environmentally relevant concentrations and a suspension of activated sludge was coupled online with HPLC

  15. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  16. Efficient decoration of nanoparticles intended for intracellular drug targeting with targeting residues, as revealed by a new indirect analytical approach.

    Science.gov (United States)

    Kaplun, Veronika; Stepensky, David

    2014-08-04

    In our previous studies, we developed a nanodrug delivery system (nano-DDS) based on poly(lactic-co-glycolic acid) PLGA nanoparticles encapsulating antigenic peptide and fluorescent marker and 3-stage approach for its decoration with peptide targeting residues. The objectives of this study were (a) to develop methods for quantitative analysis of efficiency of individual conjugation steps and (b) to determine, based on these methods, the efficiency of our 3-stage approach of nano-DDS decoration. We prepared antigenic peptide-loaded PLGA-based nano-DDSs and sequentially decorated them with specific residues using carbodiimide and Click (azide-alkyne Huisgen cycloaddition using copper(I) catalysis) reactions. The extent of cargo encapsulation and release kinetics were analyzed using HPLC-based and colorimetric analytical methods. The efficiency of residue conjugation to the nano-DDSs was analyzed using FTIR spectroscopy and by quantifying the unreacted residues in the reaction mixture (i.e., by indirect analysis of reaction efficiencies). We revealed that copper, the catalyst of the Click reactions, formed complexes with unreacted targeting residues and interfered with the analysis of their conjugation efficiency. We used penicillamine (a chelator) to disrupt these complexes, and to recover the unreacted residues. Quantitative analysis revealed that 28,800-34,000 targeting residues (corresponding to 11-13 nm(2) surface area per residue) had been conjugated to a single nano-DDS using our 3-stage decoration approach, which is much higher than previously reported conjugation efficiencies. We conclude that the applied analytical tools allow quantitative analysis of nano-DDSs and the efficiency of their conjugation with targeting residues. The 3-stage decoration approach resulted in dense conjugation of nano-DDSs with targeting residues. The present decoration and analytical approaches can be effectively applied to other types of delivery systems and other targeting

  17. Recent Development in Sample Preparation and Analytical Techniques for Determination of Quinolone Residues in Food Products.

    Science.gov (United States)

    Zhang, Zhichao; Cheng, Hefa

    2017-05-04

    Used heavily in food animal production, quinolones occur widely in food products of animal origin. Development of highly sensitive and selective analytical techniques for the detection of quinolone residues, often at trace levels, in food samples is necessary to ensure food safety and understand their public health risk. With complex matrices, food samples typically require a series of pre-treatment steps, such as powdering, homogenization, deproteinization, and filtration. This review summarizes the recent advances in extraction, concentration, and detection techniques for quinolones in food product samples, and briefly compares the advantages and limitations of major techniques. Recent development of quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction method and immunoassay- and biosensor-based detection methods for the determination of quinolones residues in food products is discussed in details. A perspective on the trends and needs of future research is also presented.

  18. HTGR analytical methods and design verification

    International Nuclear Information System (INIS)

    Neylan, A.J.; Northup, T.E.

    1982-05-01

    Analytical methods for the high-temperature gas-cooled reactor (HTGR) include development, update, verification, documentation, and maintenance of all computer codes for HTGR design and analysis. This paper presents selected nuclear, structural mechanics, seismic, and systems analytical methods related to the HTGR core. This paper also reviews design verification tests in the reactor core, reactor internals, steam generator, and thermal barrier

  19. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  20. Method for residual household waste composition studies.

    Science.gov (United States)

    Sahimaa, Olli; Hupponen, Mari; Horttanainen, Mika; Sorvari, Jaana

    2015-12-01

    The rising awareness of decreasing natural resources has brought forward the idea of a circular economy and resource efficiency in Europe. As a part of this movement, European countries have identified the need to monitor residual waste flows in order to make recycling more efficient. In Finland, studies on the composition of residual household waste have mostly been conducted using different methods, which makes the comparison of the results difficult. The aim of this study was to develop a reliable method for residual household waste composition studies. First, a literature review on European study methods was performed. Also, 19 Finnish waste composition studies were compared in order to identify the shortcomings of the current Finnish residual household waste composition data. Moreover, the information needs of different waste management authorities concerning residual household waste were studied through a survey and personal interviews. Stratification, sampling, the classification of fractions and statistical analysis were identified as the key factors in a residual household waste composition study. The area studied should be divided into non-overlapping strata in order to decrease the heterogeneity of waste and enable comparisons between different waste producers. A minimum of six subsamples, each 100 kg, from each stratum should be sorted. Confidence intervals for each waste category should be determined in order to evaluate the applicability of the results. A new three-level classification system was created based on Finnish stakeholders' information needs and compared to four other European waste composition study classifications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Rapid Methods for detection of Veterinary Drug residues in Meat

    Directory of Open Access Journals (Sweden)

    Chandan

    2010-10-01

    Full Text Available The use of substances having hormonal or thyreostatic action as well as b-agonists is banned in many countries. However, sometimes forbidden drugs may be added to feeds for illegal administration to farm animals for promoting increased muscle development or increased water retention and thus obtain an economical benefit. The result is a fraudulent overweight of meat but, what is worse, residues of these substances may remain in meat and may pose a real threat to the consumer either through exposure to the residues, transfer of antibiotic resistance or allergy risk. This has exerted a great concern among the meat consumers. The control of the absence of these forbidden substances in animal foods and feeds is regulated in the European Union by Directive 96/23/EC on measures to monitor certain substances and residues in live animals and animal products. Analytical methodology, including criteria for identification and confirmation, for the monitoring of compliance was also given in Decisions 93/256/EEC and 93/257/EEC. More recently, Decision 2002/657/EC provided rules for the analytical methods to be used in testing of official samples. New substances with anabolic properties are being detected year by year increasing the list of forbidden compounds to be tested. Furthermore, the extended practice consisting in the use of “cocktails” (mixtures of low amounts of several substances that exert a synergistic effect to have a similar growth promotion, reduces the margin for an effective analytical detection. Thus, the evolution of the “black market” is making really difficult to have an effective analytical control of the residues of these substances in foods of animal origin. Control laboratories must face an increasing demand of analysis like the growing number of residues to be analysed in different types of samples, the strict guidelines for analytical methodologies according to the latest Directives, the increased costs of such new

  2. Analytical methods of radwaste characterization

    International Nuclear Information System (INIS)

    Garcia, C.M.

    1994-10-01

    In view of the need to carry out more extensive studies on the design of newly proposed methods for the treatment of radioactive wastes collected at PNRI, this study is aimed to provide a guide in the characterization of wastes which is a preparatory step for a well-planned waste processing. (auth.). 8 refs

  3. 7 CFR 91.23 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ...-2417. (i) Standard Analytical Methods of the Member Companies of Corn Industries Research Foundation... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...

  4. A New Method to Study Analytic Inequalities

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Zhang

    2010-01-01

    Full Text Available We present a new method to study analytic inequalities involving n variables. Regarding its applications, we proved some well-known inequalities and improved Carleman's inequality.

  5. 342 analytical investigation of selected pesticide residues from fruits

    African Journals Online (AJOL)

    Osondu

    Keywords: Pesticide residues, reverse phase high performance liquid chromatography, chlorpyrifos, ... liquid chromatography hyphenated with tandem ..... Toxicology,. Applications. Toronto: Wiley-VCH. p. 541. Ortelli, D., Edder, P. and Corvi, C. (2004),. Multiresidue analysis of 74 pesticides in fruits and vegetables by liquid.

  6. Geostatistical methods applied to field model residuals

    DEFF Research Database (Denmark)

    Maule, Fox; Mosegaard, K.; Olsen, Nils

    consists of measurement errors and unmodelled signal), and is typically assumed to be uncorrelated and Gaussian distributed. We have applied geostatistical methods to analyse the residuals of the Oersted(09d/04) field model [http://www.dsri.dk/Oersted/Field_models/IGRF_2005_candidates/], which is based......The geomagnetic field varies on a variety of time- and length scales, which are only rudimentary considered in most present field models. The part of the observed field that can not be explained by a given model, the model residuals, is often considered as an estimate of the data uncertainty (which...... on 5 years of Ørsted and CHAMP data, and includes secular variation and acceleration, as well as low-degree external (magnetospheric) and induced fields. The analysis is done in order to find the statistical behaviour of the space-time structure of the residuals, as a proxy for the data covariances...

  7. Iterative Regularization with Minimum-Residual Methods

    DEFF Research Database (Denmark)

    Jensen, Toke Koldborg; Hansen, Per Christian

    2007-01-01

    subspaces. We provide a combination of theory and numerical examples, and our analysis confirms the experience that MINRES and MR-II can work as general regularization methods. We also demonstrate theoretically and experimentally that the same is not true, in general, for GMRES and RRGMRES their success......We study the regularization properties of iterative minimum-residual methods applied to discrete ill-posed problems. In these methods, the projection onto the underlying Krylov subspace acts as a regularizer, and the emphasis of this work is on the role played by the basis vectors of these Krylov...... as regularization methods is highly problem dependent....

  8. Iterative regularization with minimum-residual methods

    DEFF Research Database (Denmark)

    Jensen, Toke Koldborg; Hansen, Per Christian

    2006-01-01

    subspaces. We provide a combination of theory and numerical examples, and our analysis confirms the experience that MINRES and MR-II can work as general regularization methods. We also demonstrate theoretically and experimentally that the same is not true, in general, for GMRES and RRGMRES - their success......We study the regularization properties of iterative minimum-residual methods applied to discrete ill-posed problems. In these methods, the projection onto the underlying Krylov subspace acts as a regularizer, and the emphasis of this work is on the role played by the basis vectors of these Krylov...... as regularization methods is highly problem dependent....

  9. Analytical and computational methods in electromagnetics

    CERN Document Server

    Garg, Ramesh

    2008-01-01

    This authoritative resource offers you clear and complete explanation of this essential electromagnetics knowledge, providing you with the analytical background you need to understand such key approaches as MoM (method of moments), FDTD (Finite Difference Time Domain) and FEM (Finite Element Method), and Green's functions. This comprehensive book includes all math necessary to master the material.

  10. Mathematical methods for physical and analytical chemistry

    CERN Document Server

    Goodson, David Z

    2011-01-01

    Mathematical Methods for Physical and Analytical Chemistry presents mathematical and statistical methods to students of chemistry at the intermediate, post-calculus level. The content includes a review of general calculus; a review of numerical techniques often omitted from calculus courses, such as cubic splines and Newton's method; a detailed treatment of statistical methods for experimental data analysis; complex numbers; extrapolation; linear algebra; and differential equations. With numerous example problems and helpful anecdotes, this text gives chemistry students the mathematical

  11. Minimal residual method stronger than polynomial preconditioning

    Energy Technology Data Exchange (ETDEWEB)

    Faber, V.; Joubert, W.; Knill, E. [Los Alamos National Lab., NM (United States)] [and others

    1994-12-31

    Two popular methods for solving symmetric and nonsymmetric systems of equations are the minimal residual method, implemented by algorithms such as GMRES, and polynomial preconditioning methods. In this study results are given on the convergence rates of these methods for various classes of matrices. It is shown that for some matrices, such as normal matrices, the convergence rates for GMRES and for the optimal polynomial preconditioning are the same, and for other matrices such as the upper triangular Toeplitz matrices, it is at least assured that if one method converges then the other must converge. On the other hand, it is shown that matrices exist for which restarted GMRES always converges but any polynomial preconditioning of corresponding degree makes no progress toward the solution for some initial error. The implications of these results for these and other iterative methods are discussed.

  12. Residual replacement strategies for Krylov subspace iterative methods for the convergence of true residuals

    NARCIS (Netherlands)

    Vorst, H.A. van der; Ye, Q.

    1999-01-01

    In this paper, a strategy is proposed for alternative computations of the residual vectors in Krylov subspace methods, which improves the agreement of the computed residuals and the true residuals to the level of O(u)kAkkxk. Building on earlier ideas on residual replacement and on insights in

  13. 7 CFR 93.13 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods. Official analyses for peanuts, nuts, corn, oilseeds, and related vegetable oils are found in the following..., Englewood Cliffs, New Jersey 07632. (c) Analyst's Instruction for Aflatoxin (August 1994), S&T Instruction...

  14. Biodiesel Analytical Methods: August 2002--January 2004

    Energy Technology Data Exchange (ETDEWEB)

    Van Gerpen, J.; Shanks, B.; Pruszko, R.; Clements, D.; Knothe, G.

    2004-07-01

    Biodiesel is an alternative fuel for diesel engines that is receiving great attention worldwide. The material contained in this book is intended to provide the reader with information about biodiesel engines and fuels, analytical methods used to measure fuel properties, and specifications for biodiesel quality control.

  15. Analytic methods to generate integrable mappings

    Indian Academy of Sciences (India)

    2015-10-22

    Oct 22, 2015 ... Systematic analytic methods of deriving integrable mappings from integrable nonlinear ordinary differential, differential-difference and lattice equations are presented. More specifically, we explain how to derive integrable mappings through four different techniques namely,. dis-cretization technique,; Lax ...

  16. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. ... residual separation to separate out residual anom- alies, which are interpreted for geological .... terms, which are used for the semi-quantitative interpretation. 6.1 Computation of ...

  17. Validation of a residue method to determine pesticide residues in cucumber by using nuclear techniques

    International Nuclear Information System (INIS)

    Baysoyu, D.; Tiryaki, O.; Secer, E.; Aydin, G.

    2009-01-01

    In this study, a multi-residue method using ethyl acetate for extraction and gel permeation chromatography for clean-up was validated to determine chlorpyrifos, malathion and dichlorvos in cucumber by gas chromatography. For this purpose, homogenized cucumber samples were fortified with pesticides at 0.02 0.2, 0.8 and 1 mg/kg levels. The efficiency and repeatability of the method in extraction and cleanup steps were performed using 1 4C-carbaryl by radioisotope tracer technique. 1 4C-carbaryl recoveries after the extraction and cleanup steps were between 92.63-111.73 % with a repeatability of 4.85% (CV) and 74.83-102.22 % with a repeatability of 7.19% (CV), respectively. The homogeneity of analytical samples and the stability of pesticides during homogenization were determined using radio tracer technique and chromatographic methods, respectively.

  18. Numerical and analytical methods with Matlab

    CERN Document Server

    Bober, William; Masory, Oren

    2013-01-01

    Numerical and Analytical Methods with MATLAB® presents extensive coverage of the MATLAB programming language for engineers. It demonstrates how the built-in functions of MATLAB can be used to solve systems of linear equations, ODEs, roots of transcendental equations, statistical problems, optimization problems, control systems problems, and stress analysis problems. These built-in functions are essentially black boxes to students. By combining MATLAB with basic numerical and analytical techniques, the mystery of what these black boxes might contain is somewhat alleviated. This classroom-tested

  19. Prioritizing pesticide compounds for analytical methods development

    Science.gov (United States)

    Norman, Julia E.; Kuivila, Kathryn; Nowell, Lisa H.

    2012-01-01

    The U.S. Geological Survey (USGS) has a periodic need to re-evaluate pesticide compounds in terms of priorities for inclusion in monitoring and studies and, thus, must also assess the current analytical capabilities for pesticide detection. To meet this need, a strategy has been developed to prioritize pesticides and degradates for analytical methods development. Screening procedures were developed to separately prioritize pesticide compounds in water and sediment. The procedures evaluate pesticide compounds in existing USGS analytical methods for water and sediment and compounds for which recent agricultural-use information was available. Measured occurrence (detection frequency and concentrations) in water and sediment, predicted concentrations in water and predicted likelihood of occurrence in sediment, potential toxicity to aquatic life or humans, and priorities of other agencies or organizations, regulatory or otherwise, were considered. Several existing strategies for prioritizing chemicals for various purposes were reviewed, including those that identify and prioritize persistent, bioaccumulative, and toxic compounds, and those that determine candidates for future regulation of drinking-water contaminants. The systematic procedures developed and used in this study rely on concepts common to many previously established strategies. The evaluation of pesticide compounds resulted in the classification of compounds into three groups: Tier 1 for high priority compounds, Tier 2 for moderate priority compounds, and Tier 3 for low priority compounds. For water, a total of 247 pesticide compounds were classified as Tier 1 and, thus, are high priority for inclusion in analytical methods for monitoring and studies. Of these, about three-quarters are included in some USGS analytical method; however, many of these compounds are included on research methods that are expensive and for which there are few data on environmental samples. The remaining quarter of Tier 1

  20. Analytical detection methods for irradiated foods

    International Nuclear Information System (INIS)

    1991-03-01

    The present publication is a review of scientific literature on the analytical identification of foods treated with ionizing radiation and the quantitative determination of absorbed dose of radiation. Because of the extremely low level of chemical changes resulting from irradiation or because of the lack of specificity to irradiation of any chemical changes, a few methods of quantitative determination of absorbed dose have shown promise until now. On the other hand, the present review has identified several possible methods, which could be used, following further research and testing, for the identification of irradiated foods. An IAEA Co-ordinated Research Programme on Analytical Detection Methods for Irradiation Treatment of Food ('ADMIT'), established in 1990, is currently investigating many of the methods cited in the present document. Refs and tab

  1. Workshop on Analytical Methods in Statistics

    CERN Document Server

    Jurečková, Jana; Maciak, Matúš; Pešta, Michal

    2017-01-01

    This volume collects authoritative contributions on analytical methods and mathematical statistics. The methods presented include resampling techniques; the minimization of divergence; estimation theory and regression, eventually under shape or other constraints or long memory; and iterative approximations when the optimal solution is difficult to achieve. It also investigates probability distributions with respect to their stability, heavy-tailness, Fisher information and other aspects, both asymptotically and non-asymptotically. The book not only presents the latest mathematical and statistical methods and their extensions, but also offers solutions to real-world problems including option pricing. The selected, peer-reviewed contributions were originally presented at the workshop on Analytical Methods in Statistics, AMISTAT 2015, held in Prague, Czech Republic, November 10-13, 2015.

  2. Analytical method for thermal stress analysis of plasma facing materials

    International Nuclear Information System (INIS)

    You, J.H.; Bolt, H.

    2001-01-01

    The thermo-mechanical response of plasma facing materials (PFMs) to heat loads from the fusion plasma is one of the crucial issues in fusion technology. In this work, a fully analytical description of the thermal stress distribution in armour tiles of plasma facing components is presented which is expected to occur under typical high heat flux (HHF) loads. The method of stress superposition is applied considering the temperature gradient and thermal expansion mismatch. Several combinations of PFMs and heat sink metals are analysed and compared. In the framework of the present theoretical model, plastic flow and the effect of residual stress can be quantitatively assessed. Possible failure features are discussed

  3. Analytical method for thermal stress analysis of plasma facing materials

    Science.gov (United States)

    You, J. H.; Bolt, H.

    2001-10-01

    The thermo-mechanical response of plasma facing materials (PFMs) to heat loads from the fusion plasma is one of the crucial issues in fusion technology. In this work, a fully analytical description of the thermal stress distribution in armour tiles of plasma facing components is presented which is expected to occur under typical high heat flux (HHF) loads. The method of stress superposition is applied considering the temperature gradient and thermal expansion mismatch. Several combinations of PFMs and heat sink metals are analysed and compared. In the framework of the present theoretical model, plastic flow and the effect of residual stress can be quantitatively assessed. Possible failure features are discussed.

  4. Nuclear analytical methods for platinum group elements

    International Nuclear Information System (INIS)

    2005-04-01

    Platinum group elements (PGE) are of special interest for analytical research due to their economic importance like chemical peculiarities as catalysts, medical applications as anticancer drugs, and possible environmental detrimental impact as exhaust from automobile catalyzers. Natural levels of PGE are so low in concentration that most of the current analytical techniques approach their limit of detection capacity. In addition, Ru, Rh, Pd, Re, Os, Ir, and Pt analyses still constitute a challenge in accuracy and precision of quantification in natural matrices. Nuclear analytical techniques, such as neutron activation analysis, X ray fluorescence, or proton-induced X ray emission (PIXE), which are generally considered as reference methods for many analytical problems, are useful as well. However, due to methodological restrictions, they can, in most cases, only be applied after pre-concentration and under special irradiation conditions. This report was prepared following a coordinated research project and a consultants meeting addressing the subject from different viewpoints. The experts involved suggested to discuss the issue according to the (1) application, hence, the concentration levels encountered, and (2) method applied for analysis. Each of the different fields of application needs special consideration for sample preparation, PGE pre-concentration, and determination. Additionally, each analytical method requires special attention regarding the sensitivity and sample type. Quality assurance/quality control aspects are considered towards the end of the report. It is intended to provide the reader of this publication with state-of-the-art information on the various aspects of PGE analysis and to advise which technique might be most suitable for a particular analytical problem related to platinum group elements. In particular, many case studies described in detail from the authors' laboratory experience might help to decide which way to go. As in many cases

  5. Optimisation of octadecyl (C18) sorbent amount in QuEChERS analytical method for the accurate organophosphorus pesticide residues determination in low-fatty baby foods with response surface methodology.

    Science.gov (United States)

    Georgakopoulos, Panagiotis; Zachari, Rodanthi; Mataragas, Marios; Athanasopoulos, Panagiotis; Drosinos, Eleftherios H; Skandamis, Panagiotis N

    2011-09-15

    Three low-fatty baby food matrices were fortified with 0.01-0.2mg/kg of phorate, diazinon, chlorpyrifos and methidathion. A "quick, easy, cheap, effective, rugged and safe" - like method (QuEChERS) was used. Quantities of octadecyl (C18) sorbent differed with fortification level and matrix fat, based on central composite experimental design. Quantification was performed by Nitrogen-Phosphorus Detector gas chromatography, using matrix-matched standards. The highest (pC18 amount and the lowest C18 amounts. In meals containing vegetables (1.9% fat) and lamb (3.0% fat), 180-210mg C18 gave recoveries from 67.0% to 105.0% and absence of co-extracts. Yogurt dessert (4.5% fat) required 200-230mg C18 for similar results. Recoveries could also be predicted with <20% error by a polynomial model. The results suggest that modified QuEChERS could be effectively used in the low-fatty baby meals residue analysis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Nuclear and nuclear related analytical methods applied in environmental research

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Gheboianu, Anca; Bancuta, Iulian; Cimpoca, G. V; Stihi, Claudia; Radulescu, Cristiana; Oros Calin; Frontasyeva, Marina; Petre, Marian; Dulama, Ioana; Vlaicu, G.

    2010-01-01

    Nuclear Analytical Methods can be used for research activities on environmental studies like water quality assessment, pesticide residues, global climatic change (transboundary), pollution and remediation. Heavy metal pollution is a problem associated with areas of intensive industrial activity. In this work the moss bio monitoring technique was employed to study the atmospheric deposition in Dambovita County Romania. Also, there were used complementary nuclear and atomic analytical methods: Neutron Activation Analysis (NAA), Atomic Absorption Spectrometry (AAS) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). These high sensitivity analysis methods were used to determine the chemical composition of some samples of mosses placed in different areas with different pollution industrial sources. The concentrations of Cr, Fe, Mn, Ni and Zn were determined. The concentration of Fe from the same samples was determined using all these methods and we obtained a very good agreement, in statistical limits, which demonstrate the capability of these analytical methods to be applied on a large spectrum of environmental samples with the same results. (authors)

  7. Comparison of nuclear analytical methods with competitive methods

    International Nuclear Information System (INIS)

    1987-10-01

    The use of nuclear analytical techniques, especially neutron activation analysis, already have a 50 year old history. Today several sensitive and accurate, non-nuclear trace element analytical techniques are available and new methods are continuously developed. The IAEA is supporting the development of nuclear analytical laboratories in its Member States. In order to be able to advise the developing countries which methods to use in different applications, it is important to know the present status and development trends of nuclear analytical methods, what are their benefits, drawbacks and recommended fields of application, compared with other, non-nuclear techniques. In order to get an answer to these questions the IAEA convened this Advisory Group Meeting. This volume is the outcome of the presentations and discussions of the meeting. A separate abstract was prepared for each of the 21 papers. Refs, figs, tabs

  8. Development of an analytical method for the targeted screening and multi-residue quantification of environmental contaminants in urine by liquid chromatography coupled to high resolution mass spectrometry for evaluation of human exposures.

    Science.gov (United States)

    Cortéjade, A; Kiss, A; Cren, C; Vulliet, E; Buleté, A

    2016-01-01

    The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 4.3 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ. The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Reduction method for residual stress of welded joint using harmonic vibrational load

    International Nuclear Information System (INIS)

    Aoki, Shigeru; Nishimura, Tadashi; Hiroi, Tetsumaro; Hirai, Seiji

    2007-01-01

    Welding is widely used for construction of many structures. Since welding is a process using locally given heat, residual stress is generated near the bead. Tensile residual stress degrades fatigue strength. Some reduction methods of residual stress have been presented and, for example, heat treatment and shot peening are practically used. However, those methods need special tools and are time consuming. In this paper, a new method for reduction of residual stress using harmonic vibrational load during welding is proposed. The proposed method is examined experimentally for some conditions. Two thin plates are supported on the supporting device and butt-welded using an automatic CO 2 gas shielded arc welding machine. Residual stress in the direction of the bead is measured by using a paralleled beam X-ray diffractometer with scintillation counter after removing quenched scale chemically. First, the welding of rolled steel for general structure for some excitation frequencies is examined. Specimens are welded along the groove on both sides. For all frequencies, tensile residual stress near the bead is significantly reduced. Second, welding of the specimen made of high tensile strength steel is examined. In this case, tensile residual stress near the bead is also reduced. Finally, the proposed method is examined by an analytical method. An analytical model which consists of mass and preloaded springs with elasto-plastic characteristic is used. Reduction of residual stress is demonstrated using this model

  10. Modern methods in analytical acoustics lecture notes

    CERN Document Server

    Crighton, D G; Williams, J E Ffowcs; Heckl, M; Leppington, F G

    1992-01-01

    Modern Methods in Analytical Acoustics considers topics fundamental to the understanding of noise, vibration and fluid mechanisms. The series of lectures on which this material is based began by some twenty five years ago and has been developed and expanded ever since. Acknowledged experts in the field have given this course many times in Europe and the USA. Although the scope of the course has widened considerably, the primary aim of teaching analytical techniques of acoustics alongside specific areas of wave motion and unsteady fluid mechanisms remains. The distinguished authors of this volume are drawn from Departments of Acoustics, Engineering of Applied Mathematics in Berlin, Cambridge and London. Their intention is to reach a wider audience of all those concerned with acoustic analysis than has been able to attend the course.

  11. Big data analytics methods and applications

    CERN Document Server

    Rao, BLS; Rao, SB

    2016-01-01

    This book has a collection of articles written by Big Data experts to describe some of the cutting-edge methods and applications from their respective areas of interest, and provides the reader with a detailed overview of the field of Big Data Analytics as it is practiced today. The chapters cover technical aspects of key areas that generate and use Big Data such as management and finance; medicine and healthcare; genome, cytome and microbiome; graphs and networks; Internet of Things; Big Data standards; bench-marking of systems; and others. In addition to different applications, key algorithmic approaches such as graph partitioning, clustering and finite mixture modelling of high-dimensional data are also covered. The varied collection of themes in this volume introduces the reader to the richness of the emerging field of Big Data Analytics.

  12. Directory of Analytical Methods, Department 1820

    International Nuclear Information System (INIS)

    Whan, R.E.

    1986-01-01

    The Materials Characterization Department performs chemical, physical, and thermophysical analyses in support of programs throughout the Laboratories. The department has a wide variety of techniques and instruments staffed by experienced personnel available for these analyses, and we strive to maintain near state-of-the-art technology by continued updates. We have prepared this Directory of Analytical Methods in order to acquaint you with our capabilities and to help you identify personnel who can assist with your analytical needs. The descriptions of the various capabilities are requester-oriented and have been limited in length and detail. Emphasis has been placed on applications and limitations with notations of estimated analysis time and alternative or related techniques. A short, simplified discussion of underlying principles is also presented along with references if more detail is desired. The contents of this document have been organized in the order: bulky analysis, microanalysis, surface analysis, optical and thermal property measurements

  13. Validation of pestice multi residue analysis method on cucumber

    International Nuclear Information System (INIS)

    2011-01-01

    In this study we aimed to validate the method of multi pesticide residue analysis on cucumber. Before real sample injection, system suitability test was performed in gas chromatography (GC). For this purpose, a sensitive pesticide mixture was used for GC-NPD and estimated the performance parameters such as number of effective theoretical plates, resolution factor, asymmetry, tailing and selectivity. It was detected that the system was suitable for calibration and sample injection. Samples were fortified at the level of 0.02, 0.2, 0.8 and 1 mg/kg with mixture of dichlorvos, malathion and chloropyrifos pesticides. In the fortification step 1 4C-carbaryl was also added on homogenized analytical portions to make use of 1 4C labelled pesticides for the determining extraction efficiency. Then the basic analytical process, such as ethyl acetate extraction, filtration, evaporation and cleanup, were performed. The GPC calibration using 1 4C- carbaryl and fortification mixture (dichlorvos, malathion and chloropyrifos) showed that pesticide fraction come through the column between the 8-23 ml fractions. The recovery of 1 4C-carbaryl after the extraction and cleanup step were 92.63-111.73 % and 74.83-102.22 %, respectively. The stability of pesticides during analysis is an important factor. In this study, stability test was performed including matrix effect. Our calculation and t test results showed that above mentioned pesticides were not stabile during sample processing in our laboratory conditions and it was found that sample comminution with dry ice may improve stability. In the other part of the study, 1 4C-chloropyrifos was used to determine homogeneity of analytical portions taken from laboratory samples. Use of 1 4C labelled pesticides allows us for quick quantification analyte, even with out clean-up. The analytical results show that after sample processing with waring blender, analytical portions were homogenous. Sample processing uncertainty depending on quantity of

  14. The Emergence of the Analytical Method

    DEFF Research Database (Denmark)

    Plum, Maja

    2012-01-01

    accountability, visibility and documentation. It is argued that pedagogy is generated as a sequential and unit-specified way of working on the production of ‘the learning child’, forming a time- and material-optimising approach. Hereby, the nursery teacher, as a daily scientific researcher, comes to serve...... the nation by an ongoing observational intervention, producing the learning foundation for the entrepreneurial citizen, and thus the nation as a knowledge society in a globalised world. This is what this article terms the emergence of the analytical method....

  15. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  16. Analytical N beam position monitor method

    Science.gov (United States)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  17. Analytical approach, dissipation pattern and risk assessment of pesticide residue in green leafy vegetables: A comprehensive review.

    Science.gov (United States)

    Farha, Waziha; Abd El-Aty, A M; Rahman, Md Musfiqur; Jeong, Ji Hoon; Shin, Ho-Chul; Wang, Jing; Shin, Sung Shik; Shim, Jae-Han

    2018-01-01

    The category of 'leafy vegetables' comprises a wide range of plants, including cabbage, lettuce, leeks, spinach, Swiss chard and kale, and it forms a significant component of the human diet. Typically, leafy vegetables are low in calories and fat, are great sources of vitamins, protein, dietary fibre and minerals (including iron, calcium, and nitrates), and are rich in phytochemicals. To counter the impact of pests on vegetables, a broad variety of pesticides are used. Because of their large surface areas, leafy vegetables are expected to have high residual pesticide levels. As such, a sound analytical approach is needed to detect and quantify residue levels that are equal to or lower than the maximum residue limits, thus rendering the products safe for consumption. Overall, leafy vegetables consumed raw (after a tap water wash only), boiled or steamed contribute 2% of total vegetable consumption globally, and they might have a comparatively greater influence on health than cereal ingestion. Consequently, in this review paper, we highlight the importance of leafy vegetables, the pesticides that are commonly used on them and various analytical techniques, including sample preparation, extraction, clean-up and final detection. The effects on dissipation patterns, pre-harvest residue limits and safety/risks imposed by various pesticides are also reviewed and discussed. In conclusion, environmentally friendly extraction methods coupled with high-throughput techniques with greater reproducibility and lower uncertainty are needed for quantifying residues in leafy vegetables at very low concentrations. Commercial and household food preparation, such as washing, peeling, blanching and cooking are effective in removing most of the pesticide residues that are loosely attached on vegetables. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Method of producing pitch (distillation residue)

    Energy Technology Data Exchange (ETDEWEB)

    Stepanenko, M.A.; Belkina, T.V.; Krysin, V.P.

    1979-08-15

    A method is proposed for producing pitch by mixing hard coal pitch with anthracene fraction and thermal treatment of the mixture. The method is distinguished in that in order to increase the quality of the pitch, the anthracene fraction is subjected to thermal treatment at 250-300/sup 0/ for 10-13 hours in the presence of air. This duration of heat treatment allows one to build up in the anthracene fraction up to 20-24% of material which is not soluble and toluene, without the formation of products which are not soluble in quinoline. The fraction prepared in this manner is inserted into the initial pitch in the ratio 1:2 up to 1:9, the mixture is subject to heat treatment at temperature 360-380/sup 0/ and air consumption 7-91/kgX hours until the production of pitch with softening temperature of 85-90/sup 0/. As the initial raw material we used pitch with softening temperature of 60/sup 0/, content of substances which are not soluble in quinoline, 2.0% which are not soluble and toluene 20.6% and coking residue of 49.2%. Example. 80 grams of anthracene fraction is added to 320 grams of pitch. The anthracene fraction is subjected previously to heat treatment at 300/sup 0/ for 13 hours in the presence of air, supplied in the amount of 9 liters per hour. As a result of the heat treatment of the content of materials which are not soluble in toluence in the anthracene fraction is 24.0%, in quinoline it is 0.1%. The ratio of a pitch and thermally treated anthracene fraction in the mixture was 4:l. The produced mixture was subjected to heat treatment at 360/sup 0/ for 1.5 hours with air supply in the amount of 7 liters/ kilograms/hours. Pitch is produced with the following characteristics: softening temperature 88/sup 0/, content of substances which are not soluble in toluene 32.5%, in quinilone, 6.0%, coking residue, 56.7%. The invention can be used in the chemical coking and petrochemical industry.

  19. Determination of elements by nuclear analytical methods.

    Science.gov (United States)

    Weise, H P; Görner, W; Hedrich, M

    2001-01-01

    The working principle of nuclear analytical methods (NAMs) is not influenced by the chemical bond. Consequently, they are independent counterparts to the well-known chemical procedures. NAMs obey fundamental laws or can be described and understood thoroughly. This qualifies them as candidates for reference methods. Although following similar nuclear reaction schemes, they comprise bulk analyzing capability (neutron and photon activation analysis) as well as detection power in surface near regions of solids (ion beam techniques). Prominent features of NAMs are sensitivity, selectivity, multielement determination and linearity of the calibration function covering a concentration range of several orders of magnitude. Moreover, ion beam techniques allow depth profiling with nm-resolution in several cases while the ion microprobe additionally offers a lateral resolution in the micron-scale. As NAMs require expensive apparatus (nuclear reactor, accelerator in radioactive control areas) their availability is restricted to a small number of suitably equipped institutes. However, they are able to solve complex analytical tasks, take part in key comparisons and play an essential role in the certification of reference materials.

  20. Analytical Methods in Tracing Honey Authenticity.

    Science.gov (United States)

    Trifković, Jelena; Andrić, Filip; Ristivojević, Petar; Guzelmeric, Etil; Yesilada, Erdem

    2017-07-01

    Honey is a precious natural product that is marketed with a wide range of nutritional and medicinal properties. However, it is also a product subjected to frequent adulteration through mislabeling and mixing with cheaper and lower-quality honeys and various sugar syrups. In that sense, honey authentication regarding its genuine botanical and geographical origins, as well as the detection of any adulteration, is essential in order to protect consumer health and to avoid competition that could create a destabilized market. Various analytical techniques have been developed to detect adulterations in honey, including measuring the ratios of stable isotopes (mostly 13C/12C) and the use of different spectroscopic, chromatographic, and electrochemical methods. This review aims to provide a cross-section of contemporary analytical methods used for the determination of honey authenticity in order to help the scientific community engaged in the field of honey chemistry make appropriate choices and select the best applications that should lead to improvements in the detection and elimination of fraudulent practices in honey manufacturing.

  1. Radiochemical methods. Analytical chemistry by open learning

    Energy Technology Data Exchange (ETDEWEB)

    Geary, W.J.; James, A.M. (ed.)

    1986-01-01

    This book presents the analytical uses of radioactive isotopes within the context of radiochemistry as a whole. It is designed for scientists with relatively little background knowledge of the subject. Thus the initial emphasis is on developing the basic concepts of radioactive decay, particularly as they affect the potential usage of radioisotopes. Discussion of the properties of various types of radiation, and of factors such as half-life, is related to practical considerations such as counting and preparation methods, and handling/disposal problems. Practical aspects are then considered in more detail, and the various radioanalytical methods are outlined with particular reference to their applicability. The approach is 'user friendly' and the use of self assessment questions allows the reader to test his/her understanding of individual sections easily. For those who wish to develop their knowledge further, a reading list is provided.

  2. Analytical methods to assess nanoparticle toxicity.

    Science.gov (United States)

    Marquis, Bryce J; Love, Sara A; Braun, Katherine L; Haynes, Christy L

    2009-03-01

    During the past 20 years, improvements in nanoscale materials synthesis and characterization have given scientists great control over the fabrication of materials with features between 1 and 100 nm, unlocking many unique size-dependent properties and, thus, promising many new and/or improved technologies. Recent years have found the integration of such materials into commercial goods; a current estimate suggests there are over 800 nanoparticle-containing consumer products (The Project on Emerging Nanotechnologies Consumer Products Inventory, , accessed Oct. 2008), accounting for 147 billion USD in products in 2007 (Nanomaterials state of the market Q3 2008: stealth success, broad impact, Lux Research Inc., New York, NY, 2008). Despite this increase in the prevalence of engineered nanomaterials, there is little known about their potential impacts on environmental health and safety. The field of nanotoxicology has formed in response to this lack of information and resulted in a flurry of research studies. Nanotoxicology relies on many analytical methods for the characterization of nanomaterials as well as their impacts on in vitro and in vivo function. This review provides a critical overview of these techniques from the perspective of an analytical chemist, and is intended to be used as a reference for scientists interested in conducting nanotoxicological research as well as those interested in nanotoxicological assay development.

  3. Analytic Method for Computing Instrument Pointing Jitter

    Science.gov (United States)

    Bayard, David

    2003-01-01

    A new method of calculating the root-mean-square (rms) pointing jitter of a scientific instrument (e.g., a camera, radar antenna, or telescope) is introduced based on a state-space concept. In comparison with the prior method of calculating the rms pointing jitter, the present method involves significantly less computation. The rms pointing jitter of an instrument (the square root of the jitter variance shown in the figure) is an important physical quantity which impacts the design of the instrument, its actuators, controls, sensory components, and sensor- output-sampling circuitry. Using the Sirlin, San Martin, and Lucke definition of pointing jitter, the prior method of computing the rms pointing jitter involves a frequency-domain integral of a rational polynomial multiplied by a transcendental weighting function, necessitating the use of numerical-integration techniques. In practice, numerical integration complicates the problem of calculating the rms pointing error. In contrast, the state-space method provides exact analytic expressions that can be evaluated without numerical integration.

  4. Analytical methods associated with the recovery of uranium

    International Nuclear Information System (INIS)

    Dixon, K.

    1983-01-01

    This report summarizes various approaches made to the analysis of materials arising from the processing of Karoo deposits for uranium. These materials include head and residue samples, aqueous solutions and organic solvents and, finally, the precipitated cakes of the elements recovered, i.e. uranium, molybdenum, and arsenic. Analysis was required for these elements and also vanadium, carbon, sulphur, and carbonate in the head and residue samples. The concentration of uranium, molybdenum, and arsenic, other than in the precipitated cakes, ranges from 1 to 2000μg/g, and that of carbon, sulphur, and carbonate from 0,1 to 5 per cent. The analysis of cakes necessitates the determination of silver, arsenic, iron, copper, calcium, magnesium, manganese, molybdenum, lead, tin, titanium, and vanadium within the range 1 to 1000μg/g, and of sodium and silica within the range 10 to 20 000μg/g. The methods used include combustion methods for carbon, sulphur, and carbonate, and atomic-absorption, X-ray-fluorescence, and emission methods for the other analytes. The accuracy of the analysis is within 10 per cent

  5. Analytical method for Buddleja colorants in foods.

    Science.gov (United States)

    Aoki, H; Kuze, N; Ichi, T; Koda, T

    2001-04-01

    Buddleja yellow colorant derived from Buddleja officinalis Maxim. has recently been approved for use as a new kind of natural colorant for food additives in China. In order to distinguish Buddleja yellow colorant from other yellow colorants, two known phenylpropanoid glycosides, acteoside (= verbascoside) and poliumoside, were isolated from the colorant as marker substances for Buddleja yellow colorant. Poliumoside has not been detected in B. officinalis Maxim. previously. These phenylpropanoid glycosides were not detected in the fruits of Gardenia jasminoides Ellis or in the stamens of the flowers of Crocus sativus L., which also contain crocetin derivatives as coloring components, using a photodiode array and mass chromatograms. Thus, an analytical HPLC method was developed to distinguish foods that have been colored with yellow colorants containing crocetin derivatives, using phenylpropanoid glycosides as markers.

  6. A single-step pesticide extraction and clean-up multi-residue analytical method by selective pressurized liquid extraction followed by on-line solid phase extraction and ultra-high-performance liquid chromatography-tandem mass spectrometry for complex matrices.

    Science.gov (United States)

    Rodrigues, Elsa Teresa; Pardal, Miguel Ângelo; Salgueiro-González, Noelia; Muniategui-Lorenzo, Soledad; Alpendurada, Maria Fátima

    2016-06-24

    Pesticides, a group of compounds linked to human activity, may, when in toxic levels, have a profound effect on water quality, and hence result in adverse consequences to aquatic life and ultimately to human health. Analytical challenges arise when successfully trying to determine these levels in environmental complex matrices. Therefore, fast, simple, sensitive and selective analytical methodologies for multi-residue determination of pesticides (atrazine, azoxystrobin, bentazon, λ-cyhalothrin, penoxsulam and terbuthylazine) in sediment, macrophytes (algae and aquatic plants) and aquatic animals were developed and validated. The established methods were matrix-dependent and were based on Selective Pressurized Liquid Extraction (SPLE) followed by on-line Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (on-line SPE-UPLC-ESI-MS/MS). This cutting-edge research methodology uses a small amount of sample, is time saving and reduces the use of organic solvents in compliance with Green Chemistry principles. The analytical features were adequate for all compounds in all studied matrices. The established methodology was applied on real marine samples and no pesticide concentrations above their respective method quantification limits were measured in sediments or aquatic plants. However, terbuthylazine was found in the macroalgae Ulva spp. (108ngg(-1)dw) and all the prospected pesticides were measured above their respective method quantification limits in the bivalve Scrobicularia plana (atrazine: 48ngg(-1)dw, azoxystrobin: 64ngg(-1)dw, bentazon: 33ngg(-1)dw, λ-cyhalothrin: 2531ngg(-1)dw, penoxsulam: 50ngg(-1)dw, and terbuthylazine: 44ngg(-1)dw). Copyright © 2016 Elsevier B.V. All rights reserved.

  7. An analytical model to predict and minimize the residual stress of laser cladding process

    Science.gov (United States)

    Tamanna, N.; Crouch, R.; Kabir, I. R.; Naher, S.

    2018-02-01

    Laser cladding is one of the advanced thermal techniques used to repair or modify the surface properties of high-value components such as tools, military and aerospace parts. Unfortunately, tensile residual stresses generate in the thermally treated area of this process. This work focuses on to investigate the key factors for the formation of tensile residual stress and how to minimize it in the clad when using dissimilar substrate and clad materials. To predict the tensile residual stress, a one-dimensional analytical model has been adopted. Four cladding materials (Al2O3, TiC, TiO2, ZrO2) on the H13 tool steel substrate and a range of preheating temperatures of the substrate, from 300 to 1200 K, have been investigated. Thermal strain and Young's modulus are found to be the key factors of formation of tensile residual stresses. Additionally, it is found that using a preheating temperature of the substrate immediately before laser cladding showed the reduction of residual stress.

  8. Analytical strategy for the detection of antibiotic residues in sheep and goat’s milk

    Directory of Open Access Journals (Sweden)

    M. Carmen Beltrán

    2015-03-01

    Full Text Available The use of antibiotics to treat mastitis and other infectious diseases in dairy sheep and goats is a widespread practice nowadays that can, when not properly applied, result in the contamination of the milk supply. Spanish legislation establishes the control of the presence of antibiotic residues in sheep and goat’s milk using screening methods that detect, at least, beta-lactam drugs. Microbial inhibitor tests using Geobacillus stearothermophilus var. calidolactis and specific receptor-binding assays are most widely employed for this purpose. The detection rates of screening tests routinely used in Spain have been calculated considering the frequency of use of veterinary drugs commonly applied in ovine and caprine livestock to treat and prevent mastitis as well as the test sensitivity toward these substances at safety levels. In general, the use of a single test allows detecting 62.8-82.4% of the antibiotics employed. For sheep milk, the total detection range achieved with microbial tests was significantly higher than that reached with rapid receptor tests. However, no significant differences between the two types of methods were found when goat’s milk was analysed. In both types of milk, the simultaneous use of two screening tests with a different analytical basis increases the total detection range significantly, reaching values ≥ 90% in some cases (81.5-90.1% for sheep and 84.7-92.6% for goats. However, the periodical use of screening tests able to detect quinolones, macrolides or aminoglycosides would be recommended to carry out more efficient screening and ensure the safety of milk and dairy products from sheep and goats.

  9. Analytical strategy for the detection of antibiotic residues in sheep and goat’s milk

    Energy Technology Data Exchange (ETDEWEB)

    Beltrán, M.C.; Althaus, R.L.; Molina, A.; Berruga, M.I.; Molina, M.P.

    2015-07-01

    The use of antibiotics to treat mastitis and other infectious diseases in dairy sheep and goats is a widespread practice nowadays that can, when not properly applied, result in the contamination of the milk supply. Spanish legislation establishes the control of the presence of antibiotic residues in sheep and goat’s milk using screening methods that detect, at least, beta-lactam drugs. Microbial inhibitor tests using Geobacillus stearothermophilus var. calidolactis and specific receptor-binding assays are most widely employed for this purpose. The detection rates of screening tests routinely used in Spain have been calculated considering the frequency of use of veterinary drugs commonly applied in ovine and caprine livestock to treat and prevent mastitis as well as the test sensitivity toward these substances at safety levels. In general, the use of a single test allows detecting 62.8-82.4% of the antibiotics employed. For sheep milk, the total detection range achieved with microbial tests was significantly higher than that reached with rapid receptor tests. However, no significant differences between the two types of methods were found when goat's milk was analysed. In both types of milk, the simultaneous use of two screening tests with a different analytical basis increases the total detection range significantly, reaching values ≥ 90% in some cases (81.5-90.1% for sheep and 84.7-92.6% for goats). However, the periodical use of screening tests able to detect quinolones, macrolides or aminoglycosides would be recommended to carry out more efficient screening and ensure the safety of milk and dairy products from sheep and goats. (Author)

  10. The method for measuring residual stress in stainless steel pipes

    International Nuclear Information System (INIS)

    Shimov, Georgy; Rozenbaum, Mikhail; Serebryakov, Alexandr; Serebryakov, Andrey

    2016-01-01

    The main reason of appearance and growth of corrosion damages of the nuclear steam generator heat exchanger tubes is the process of stress-corrosion cracking of metal under the influence of residual tensile stress. Methods used in the production for estimating residual stresses (such as a method of ring samples) allow measuring only the average tangential stress of the pipe wall. The method of ring samples does not allow to assess the level of residual stress in the surface layer of the pipe. This paper describes an experimental method for measuring the residual stresses on the pipe surface by etching a thin surface layer of the metal. The construction and working principle of a trial installation are described. The residual stresses in the wall of the tubes 16 × 1.5 mm (steel AISI 321) for nuclear steam generators is calculated. Keywords: heat exchange pipes, stress corrosion cracking, residual stresses, stress distribution, stress measurement.

  11. Current research, regulation, risk, analytical methods and monitoring results for nicarbazin in chicken meat: A perspective review.

    Science.gov (United States)

    Bacila, Danniele Miranda; Feddern, Vivian; Mafra, Luciana Igarashi; Scheuermann, Gerson Neudí; Molognoni, Luciano; Daguer, Heitor

    2017-09-01

    This review presents up-to-date information about current research on nicarbazin, one of the most used anticoccidials in poultry production. The focus is to elucidate regulation concerning nicarbazin, limits for its residues in food, how maximum residue limits in different countries are calculated regarding edible chicken tissues and the possible implications in human health. Analytical methods to extract and quantify this residue, expressed as dinitrocarbanilide (DNC) are presented and discussed, including qualitative screening and quantitative/confirmatory analytical methods. Monitoring results and occurrence of DNC residues in chicken meat are discussed. Additionally, the causes of eventual chicken meat contamination and possible solutions to reduce or eliminate DNC residue in tissues are also presented. The paper concludes with perspectives, the current state of DNC residue analysis and suggestions for future research, especially considering the gap in the study of residue recycling effect due to continuous chicken litter use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Satellite Magnetic Residuals Investigated With Geostatistical Methods

    DEFF Research Database (Denmark)

    Fox Maule, Chaterine; Mosegaard, Klaus; Olsen, Nils

    2005-01-01

    The geomagnetic field varies on a variety of time- and length scales, which are only rudimentarily considered in most present field models. The part of the observed field that cannot be explained by a given model, the model residuals, is often considered as an estimate of the data uncertainty (wh...

  13. A tiered analytical protocol for the characterization of heavy oil residues at petroleum-contaminated hazardous waste sites

    International Nuclear Information System (INIS)

    Pollard, S.J.T.; Kenefick, S.L.; Hrudey, S.E.; Fuhr, B.J.; Holloway, L.R.; Rawluk, M.

    1994-01-01

    The analysis of hydrocarbon-contaminated soils from abandoned refinery sites in Alberta, Canada is used to illustrate a tiered analytical approach to the characterization of complex hydrocarbon wastes. Soil extracts isolated from heavy oil- and creosote-contaminated sites were characterized by thin layer chromatography with flame ionization detection (TLC-FID), ultraviolet fluorescence, simulated distillation (GC-SIMDIS) and chemical ionization GC-MS analysis. The combined screening and detailed analytical methods provided information essential to remedial technology selection including the extent of contamination, the class composition of soil extracts, the distillation profile of component classes and the distribution of individual class components within various waste fractions. Residual contamination was characteristic of heavy, degraded oils, consistent with documented site operations and length of hydrocarbon exposure at the soil surface

  14. Hanford environmental analytical methods: Methods as of March 1990

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually

  15. Microgenetic Learning Analytics Methods: Workshop Report

    Science.gov (United States)

    Aghababyan, Ani; Martin, Taylor; Janisiewicz, Philip; Close, Kevin

    2016-01-01

    Learning analytics is an emerging discipline and, as such, benefits from new tools and methodological approaches. This work reviews and summarizes our workshop on microgenetic data analysis techniques using R, held at the second annual Learning Analytics Summer Institute in Cambridge, Massachusetts, on 30 June 2014. Specifically, this paper…

  16. Multi-residue methods for confirmatory determination of antibiotics in milk.

    Science.gov (United States)

    Samanidou, Victoria; Nisyriou, Styliani

    2008-06-01

    The prevalent use of antibiotics, e. g. sulphonamides, tetracyclines, beta-lactams, macrolides, aminoglycosides, etc., in dairy farming to prevent and treat microbial infections e. g. mastitis, can be a potential source of veterinary drug residues in milk. Antibiotic residues constitute a risk to human health, since they can cause allergic reactions in hypersensitive individuals or they may lead to the appearance of drug-resistant bacteria. Analysis of these residues plays a key role in ensuring food safety. Regulatory agencies in the European Union and in other countries have established maximum residue limits and requirements concerning the performance of analytical methods and the interpretation of the results. This review describes the state of the art in the analytical strategies concerning the multi-class as well as the multi-residue analysis of antibiotics in milk. Since milk is a complex matrix due to its high protein and fat content, which often interfere in analytical procedures, special focus has been placed on sample preparation: extraction and clean-up. Confirmation of antibiotic residues according to European Decision 657/2002/EC has been also discussed.

  17. The new method for the residual gas density measurements

    CERN Document Server

    Anashin, V V; Krasnov, A A; Malyshev, O B; Nas'mov, V P; Pyata, E I; Shaftan, T V

    2001-01-01

    A new method of measurement for residual gas density in the vacuum chambers in presence of synchrotron radiation (SR) is described. The method is based on using a photomultiplier tube for the detection of the SR-stimulated residual gas luminescence, which is proportional to the residual gas density and SR intensity. The design of the experimental setup and results of the measurements of densities of residual gases (H sub 2 , CO sub 2 , CO, N sub 2 , Ar and O sub 2) are submitted.

  18. Residual power series method for fractional Sharma-Tasso-Olever equation

    Directory of Open Access Journals (Sweden)

    Amit Kumar

    2016-02-01

    Full Text Available In this paper, we introduce a modified analytical approximate technique to obtain solution of time fractional Sharma-Tasso-Olever equation. First, we present an alternative framework of the Residual power series method (RPSM which can be used simply and effectively to handle nonlinear fractional differential equations arising in several physical phenomena. This method is basically based on the generalized Taylor series formula and residual error function. A good result is found between our solution and the given solution. It is shown that the proposed method is reliable, efficient and easy to implement on all kinds of fractional nonlinear problems arising in science and technology.

  19. 7 CFR 94.4 - Analytical methods.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...) FDA Bacteriological Analytical Manual (BAM), AOAC INTERNATIONAL, 481 North Frederick Avenue, Suite 500...

  20. Chemical analysis of solid residue from liquid and solid fuel combustion: Method development and validation

    Energy Technology Data Exchange (ETDEWEB)

    Trkmic, M. [University of Zagreb, Faculty of Mechanical Engineering and Naval Architecturek Zagreb (Croatia); Curkovic, L. [University of Zagreb, Faculty of Chemical Engineering and Technology, Zagreb (Croatia); Asperger, D. [HEP-Proizvodnja, Thermal Power Plant Department, Zagreb (Croatia)

    2012-06-15

    This paper deals with the development and validation of methods for identifying the composition of solid residue after liquid and solid fuel combustion in thermal power plant furnaces. The methods were developed for energy dispersive X-ray fluorescence (EDXRF) spectrometer analysis. Due to the fuels used, the different composition and the location of creation of solid residue, it was necessary to develop two methods. The first method is used for identifying solid residue composition after fuel oil combustion (Method 1), while the second method is used for identifying solid residue composition after the combustion of solid fuels, i. e. coal (Method 2). Method calibration was performed on sets of 12 (Method 1) and 6 (Method 2) certified reference materials (CRM). CRMs and analysis test samples were prepared in pellet form using hydraulic press. For the purpose of method validation the linearity, accuracy, precision and specificity were determined, and the measurement uncertainty of methods for each analyte separately was assessed. The methods were applied in the analysis of real furnace residue samples. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Science.gov (United States)

    2010-07-01

    ... § 425.03 Sulfide analytical methods and applicability. (a) The potassium ferricyanide titration method... ferricyanide titration method for the determination of sulfide in wastewaters discharged by plants operating in... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Sulfide analytical methods and...

  2. A National Residue Control Plan from the analytical perspective-The Brazilian case

    International Nuclear Information System (INIS)

    Mauricio, Angelo de Q; Lins, Erick S.; Alvarenga, Marcelo B.

    2009-01-01

    Food safety is a strategic topic entailing not only national public health aspects but also competitiveness in international trade. An important component of any food safety program is the control and monitoring of residues posed by certain substances involved in food production. In turn, a National Residue Control Plan (NRCP) relies on an appropriate laboratory network, not only to generate analytical results, but also more broadly to verify and co-validate the controls built along the food production chain. Therefore laboratories operating under a NRCP should work in close cooperation with inspection bodies, fostering the critical alignment of the whole system with the principles of risk analysis. Beyond producing technically valid results, these laboratories should arguably be able to assist in the prediction and establishment of targets for official control. In pursuit of analytical excellence, the Brazilian government has developed a strategic plan for Official Agricultural Laboratories. Inserted in a national agenda for agricultural risk analysis, the plan has succeeded in raising laboratory budget by approximately 200%, it has started a rigorous program for personnel capacity-building, it has initiated strategic cooperation with international reference centres, and finally, it has completely renewed instrumental resources and rapidly triggered a program aimed at full laboratory compliance with ISO/IEC 17025 requirements

  3. A National Residue Control Plan from the analytical perspective--the Brazilian case.

    Science.gov (United States)

    Mauricio, Angelo de Q; Lins, Erick S; Alvarenga, Marcelo B

    2009-04-01

    Food safety is a strategic topic entailing not only national public health aspects but also competitiveness in international trade. An important component of any food safety program is the control and monitoring of residues posed by certain substances involved in food production. In turn, a National Residue Control Plan (NRCP) relies on an appropriate laboratory network, not only to generate analytical results, but also more broadly to verify and co-validate the controls built along the food production chain. Therefore laboratories operating under a NRCP should work in close cooperation with inspection bodies, fostering the critical alignment of the whole system with the principles of risk analysis. Beyond producing technically valid results, these laboratories should arguably be able to assist in the prediction and establishment of targets for official control. In pursuit of analytical excellence, the Brazilian government has developed a strategic plan for Official Agricultural Laboratories. Inserted in a national agenda for agricultural risk analysis, the plan has succeeded in raising laboratory budget by approximately 200%, it has started a rigorous program for personnel capacity-building, it has initiated strategic cooperation with international reference centres, and finally, it has completely renewed instrumental resources and rapidly triggered a program aimed at full laboratory compliance with ISO/IEC 17025 requirements.

  4. Sensor Network Information Analytical Methods: Analysis of Similarities and Differences

    Directory of Open Access Journals (Sweden)

    Chen Jian

    2014-04-01

    Full Text Available In the Sensor Network information engineering literature, few references focus on the definition and design of Sensor Network information analytical methods. Among those that do are Munson, et al. and the ISO standards on functional size analysis. To avoid inconsistent vocabulary and potentially incorrect interpretation of data, Sensor Network information analytical methods must be better designed, including definitions, analysis principles, analysis rules, and base units. This paper analyzes the similarities and differences across three different views of analytical methods, and uses a process proposed for the design of Sensor Network information analytical methods to analyze two examples of such methods selected from the literature.

  5. A view on the analytical design of future risk based residue control

    NARCIS (Netherlands)

    Ginkel, van Leendert A.; Sterk, Saskia S.

    2016-01-01

    The current laboratory network system in support of residue monitoring programmes within the EU formally started in the early 1990s. Since then, it has undergone a gentle evolution incorporating new techniques and methods for quality assurance and, in parallel to the extension of the European

  6. Nonlinear ordinary differential equations analytical approximation and numerical methods

    CERN Document Server

    Hermann, Martin

    2016-01-01

    The book discusses the solutions to nonlinear ordinary differential equations (ODEs) using analytical and numerical approximation methods. Recently, analytical approximation methods have been largely used in solving linear and nonlinear lower-order ODEs. It also discusses using these methods to solve some strong nonlinear ODEs. There are two chapters devoted to solving nonlinear ODEs using numerical methods, as in practice high-dimensional systems of nonlinear ODEs that cannot be solved by analytical approximate methods are common. Moreover, it studies analytical and numerical techniques for the treatment of parameter-depending ODEs. The book explains various methods for solving nonlinear-oscillator and structural-system problems, including the energy balance method, harmonic balance method, amplitude frequency formulation, variational iteration method, homotopy perturbation method, iteration perturbation method, homotopy analysis method, simple and multiple shooting method, and the nonlinear stabilized march...

  7. Development of an Analytical Method for Explosive Residues in Soil,

    Science.gov (United States)

    1987-06-01

    pesticides from spiked dry (1983) compared acetone, acetonitrile, methylene chlo- soil using an ultrasonic probe, an ultrasonic bath and ride-methanol... photodegradation of tion on XAD-4 resin, extraction using ethyl acetate, and the explosive-forming nitrite ion, which is detected by determination by GC on a

  8. Different Analytical Procedures for the Study of Organic Residues in Archeological Ceramic Samples with the Use of Gas Chromatography-mass Spectrometry.

    Science.gov (United States)

    Kałużna-Czaplińska, Joanna; Rosiak, Angelina; Kwapińska, Marzena; Kwapiński, Witold

    2016-01-01

    The analysis of the composition of organic residues present in pottery is an important source of information for historians and archeologists. Chemical characterization of the materials provides information on diets, habits, technologies, and original use of the vessels. This review presents the problem of analytical studies of archeological materials with a special emphasis on organic residues. Current methods used in the determination of different organic compounds in archeological ceramics are presented. Particular attention is paid to the procedures of analysis of archeological ceramic samples used before gas chromatography-mass spectrometry. Advantages and disadvantages of different extraction methods and application of proper quality assurance/quality control procedures are discussed.

  9. Treatment Method for Fermi Barrel Sodium Metal Residues

    Energy Technology Data Exchange (ETDEWEB)

    Steven R. Sherman; Collin J. Knight

    2005-06-01

    Fermi barrels are 55-gallon drums that once contained bulk sodium metal from the shutdown Fermi 1 breeder reactor facility, and now contain residual sodium metal and other sodium/air reaction products. This report provides a residual sodium treatment method and proposed quality assurance steps that will ensure that all residual sodium is deactivated and removed from the Fermi barrels before disposal. The treatment method is the application of humidified carbon dioxide to the residual sodium followed by a water wash. The experimental application of the treatment method to six Fermi barrels is discussed, and recommendations are provided for further testing and evaluation of the method. Though more testing would allow for a greater refinement of the treatment technique, enough data has been gathered from the tests already performed to prove that 100% compliance with stated waste criteria can be achieved.

  10. Convergence of a residual based artificial viscosity finite element method

    KAUST Repository

    Nazarov, Murtazo

    2013-02-01

    We present a residual based artificial viscosity finite element method to solve conservation laws. The Galerkin approximation is stabilized by only residual based artificial viscosity, without any least-squares, SUPG, or streamline diffusion terms. We prove convergence of the method, applied to a scalar conservation law in two space dimensions, toward an unique entropy solution for implicit time stepping schemes. © 2012 Elsevier B.V. All rights reserved.

  11. Analysis of residual toluene in food packaging via headspace extraction method using gas chromatography

    International Nuclear Information System (INIS)

    Lim, Ying Chin; Mohd Marsin Sanagi

    2008-01-01

    Polymeric materials are used in many food contact applications as packaging material. The presence of residual toluene in this food packaging material can migrate into food and thus affect the quality of food. In this study, a manual headspace analysis was successfully designed and developed. The determination of residual toluene was carried out with standard addition method and multiple headspace extraction, MHE) method using gas chromatography-flame ionization detector, GC-FID). Identification of toluene was performed by comparison of its retention time with standard toluene and GC-MS. It was found that the suitable heating temperature was 180 degree Celsius with an optimum heating time of 10 minutes. The study also found that the concentration of residual toluene in multicolored sample was higher compared to mono colored sample whereas residual toluene in sample analyzed using standard addition method was higher compared to MHE method. However, comparison with the results obtained from De Paris laboratory, France found that MHE method gave higher accuracy for sample with low analyte concentration. On the other hand, lower accuracy was obtained for sample with high concentration of residual toluene due to systematic errors. Comparison between determination methods showed that MHE method is more precise compared to standard addition method. (author)

  12. Testing the efficiency of extraction of incurred residues from soil with optimized multi-residue method.

    Science.gov (United States)

    Suszter, Gabriella K; Ambrus, Árpád

    2017-08-03

    The reproducibility of extraction of residues from spiked soil samples and from soils containing incurred residues was tested with 14 C-labeled test compounds of different physical-chemical properties. Nearly 100% of the compounds added to the sample before extraction could be recovered with an average reproducibility relative standard deviation (CV) of 5.4%. The additional steps of the determination process (cleanup, evaporation, etc.) contributed to the major part of the variability of the results (CV = 10-20%). The incurred residues were most efficiently extracted with acetone for 30 min followed by the mixture of acetone/ethyl acetate 1:1 for additional 30 min. However, they could only be recovered at various extent (64-90% of total residues), underlying the importance of testing the efficiency of extraction. The residues were identified and quantified by gas chromatography applying thermionic detector. The performance parameters of the method complied with the international method validation guidelines, and they proved to be robust and suitable for determination of pesticide residues in soils of widely different physical-chemical properties.

  13. Recent developments in analytical detection methods for radiation processed foods

    International Nuclear Information System (INIS)

    Wu Jilan

    1993-01-01

    A short summary of the programmes of 'ADMIT' (FAO/IAEA) and the developments in analytical detection methods for radiation processed foods has been given. It is suggested that for promoting the commercialization of radiation processed foods and controlling its quality, one must pay more attention to the study of analytical detection methods of irradiated food

  14. An Analytical Procedure for the Equipercentile Method of Equating Tests.

    Science.gov (United States)

    Lindsay, Carl A.; Prichard, Mark A.

    Prior use of the equipercentile method of test equating was based on a graphic procedure which is tedious, subject to smoothing errors, and non-analytical. Recognition of the equipercentile method as a curve-fitting procedure for two cumulative percentage distributions leads to a proposed analytical solution to the problem through use of linear…

  15. Residual Stress Analysis Based on Acoustic and Optical Methods

    Directory of Open Access Journals (Sweden)

    Sanichiro Yoshida

    2016-02-01

    Full Text Available Co-application of acoustoelasticity and optical interferometry to residual stress analysis is discussed. The underlying idea is to combine the advantages of both methods. Acoustoelasticity is capable of evaluating a residual stress absolutely but it is a single point measurement. Optical interferometry is able to measure deformation yielding two-dimensional, full-field data, but it is not suitable for absolute evaluation of residual stresses. By theoretically relating the deformation data to residual stresses, and calibrating it with absolute residual stress evaluated at a reference point, it is possible to measure residual stresses quantitatively, nondestructively and two-dimensionally. The feasibility of the idea has been tested with a butt-jointed dissimilar plate specimen. A steel plate 18.5 mm wide, 50 mm long and 3.37 mm thick is braze-jointed to a cemented carbide plate of the same dimension along the 18.5 mm-side. Acoustoelasticity evaluates the elastic modulus at reference points via acoustic velocity measurement. A tensile load is applied to the specimen at a constant pulling rate in a stress range substantially lower than the yield stress. Optical interferometry measures the resulting acceleration field. Based on the theory of harmonic oscillation, the acceleration field is correlated to compressive and tensile residual stresses qualitatively. The acoustic and optical results show reasonable agreement in the compressive and tensile residual stresses, indicating the feasibility of the idea.

  16. A Novel Residual Frequency Estimation Method for GNSS Receivers.

    Science.gov (United States)

    Nguyen, Tu Thi-Thanh; La, Vinh The; Ta, Tung Hai

    2018-01-04

    In Global Navigation Satellite System (GNSS) receivers, residual frequency estimation methods are traditionally applied in the synchronization block to reduce the transient time from acquisition to tracking, or they are used within the frequency estimator to improve its accuracy in open-loop architectures. There are several disadvantages in the current estimation methods, including sensitivity to noise and wide search space size. This paper proposes a new residual frequency estimation method depending on differential processing. Although the complexity of the proposed method is higher than the one of traditional methods, it can lead to more accurate estimates, without increasing the size of the search space.

  17. An Iteration Method Generating Analytical Solutions for Blasius Problem

    OpenAIRE

    Yun, Beong In

    2011-01-01

    We derive a new iteration method for finding solution of the generalized Blasius problem. This method results in the analytical series solutions which are consistent with the existing series solutions for some special cases.

  18. Application of the contour method to validate residual stress predictions

    International Nuclear Information System (INIS)

    Welding is the most widespread method employed to join metallic components in nuclear power plants. This is an aggressive process that introduces complex three-dimensional residual stresses of substantial magnitude into engineering components. For safety-critical applications it can be of crucial importance to have an accurate characterisation of the residual stress field present in order to assess plant lifetime and risk of failure. Finite element modelling approaches are being increasingly employed by engineers to predict welding residual stresses. However, such predictions are challenging owing to the innate complexity of the welding process and can give highly variable results. Therefore, it is always desirable to validate residual stress predictions by experimental data. This paper illustrates how the contour method of measuring residual stress can be applied to various weldments in order to provide high quality experimental data. The contour method results are compared with data obtained by other well-established residual stress measurement techniques such as neutron diffraction and slitting methods and show a very satisfactory correlation. (author)

  19. Detection of residues antibiotics in food using a microbiological method

    International Nuclear Information System (INIS)

    Ben Ali, Ahmed

    2007-01-01

    Antibiotics are effective therapeutic agents because of their property of selective bacterial toxicity which helps controlling infections. Animals, just like humans, can be treated with antibiotics. This use of antibiotics can lead to the development of resistance. Resistant strains may cause severe infections in humans and animals. In addition, antibiotic residues might represent a problem for human health. Our objective is to develop a microbiological method for the detection of antibiotic residues in poultry(muscle, liver,...). For this purpose, antibiotic sensitive bacteria and selective agar media were used. An inhibition growth zone surrounds each of the food samples containing antibiotic residues after a prescribed incubation time. (Author). 23 refs

  20. Application of a radiometric enzymic method for monitoring organophosphorus and carbamate insecticide residues in water of the Danube River

    International Nuclear Information System (INIS)

    Horvath, L.; Volford, J.; Bursics, L.; Forster, T.

    1983-01-01

    Pesticide residue analyses are conventionally based on gas chromatography. These analytic procedures include tedious extraction and clear-up manipulations prior to the actual gas chromatographic determinations. Radioenzymatic method was recently applied in a residue monitoring programme on the Danube River. The programme has demonstrated that the radioenzymatic method has many advantages as a monitoring procedure in aquatic environment. Quick information can be gained without tedious sample clear-up procedure. The anticholinesteratic pesticides and the anticholinesteratic activities can be detected

  1. Determination of aluminum by four analytical methods

    International Nuclear Information System (INIS)

    Hanson, T.J.; Smetana, K.M.

    1975-11-01

    Four procedures have been developed for determining the aluminum concentration in basic matrices. Atomic Absorption Spectroscopy (AAS) was the routine method of analysis. Citrate was required to complex the aluminum and eliminate matrix effects. AAS was the least accurate of the four methods studied and was adversely affected by high aluminum concentrations. The Fluoride Electrode Method was the most accurate and precise of the four methods. A Gran's Plot determination was used to determine the end point and average standard recovery was 100% +- 2%. The Thermometric Titration Method was the fastest method for determining aluminum and could also determine hydroxide concentration at the same time. Standard recoveries were 100% +- 5%. The pH Electrode Method also measures aluminum and hydroxide content simultaneously, but is less accurate and more time consuming that the thermal titration. Samples were analyzed using all four methods and results were compared to determine the strengths and weaknesses of each. On the basis of these comparisons, conclusions were drawn concerning the application of each method to our laboratory needs

  2. Multiresidue analytical procedures for pesticides residues in vegetable products; Metodi mutiresiduo per l`analisi di residui di antiparassitari in prodotti vegetali

    Energy Technology Data Exchange (ETDEWEB)

    Gruppo di lavoro per i residui di antiparassitari della Commissione permanente di coordinamento interregionale per i problemi relativi al controllo ufficiale dei prodotti alimentari

    1997-09-01

    Multiresidue methods for pesticide residues in vegetable products, most frequently used by laboratories of the Italian national health service, by the regional and provincial agencies for environmental protection and by the National health institute. The analytical behaviour is presented for 249 pesticides through the different steps of extraction and cleanup, along with data for the gas chromatography (GC), gas chromatography coupled to mass spectrometry (GC/MS) and high performance liquid chromatography coupled to spectrophotometric detector (HPL/UV).

  3. Learner Language Analytic Methods and Pedagogical Implications

    Science.gov (United States)

    Dyson, Bronwen

    2010-01-01

    Methods for analysing interlanguage have long aimed to capture learner language in its own right. By surveying the cognitive methods of Error Analysis, Obligatory Occasion Analysis and Frequency Analysis, this paper traces reformulations to attain this goal. The paper then focuses on Emergence Analysis, which fine-tunes learner language analysis…

  4. Finite analytic method for modeling variably saturated flows.

    Science.gov (United States)

    Zhang, Zaiyong; Wang, Wenke; Gong, Chengcheng; Yeh, Tian-Chyi Jim; Wang, Zhoufeng; Wang, Yu-Li; Chen, Li

    2018-04-15

    This paper develops a finite analytic method (FAM) for solving the two-dimensional Richards' equation. The FAM incorporates the analytic solution in local elements to formulate the algebraic representation of the partial differential equation of unsaturated flow so as to effectively control both numerical oscillation and dispersion. The FAM model is then verified using four examples, in which the numerical solutions are compared with analytical solutions, solutions from VSAFT2, and observational data from a field experiment. These numerical experiments show that the method is not only accurate but also efficient, when compared with other numerical methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Validation of a new analytical procedure for determination of residual solvents in [{sup 18}F]FDG by gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Flávia M.; Costa, Cassiano L.S.; Silva, Juliana B.; Ferreira, Soraya M.Z.M.D., E-mail: flaviabiomedica@yahoo.com.br [Centro de Desenvolvimento da Tecnologia Nuclear (UPPR/CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Produção de Radiofármacos

    2017-07-01

    Fludeoxyglucose F 18 ([{sup 18}F]FDG) is the most used radiopharmaceutical for positron emission tomography, especially on oncology. Organic solvents such as ether, ethanol and acetonitrile might be used in the synthesis of [{sup 18}F]FDG; however, they might not be completely removed during purification steps. The determination of residual solvents in [{sup 18}F]FDG is required in the European Pharmacopoeia (EP) and the United States Pharmacopeia (USP) monographs. While the procedure described in the EP is quite general, the one described in the USP requires a long runtime (about 13 minutes). In this work a simple and fast (4-minute) analytical procedure was developed and validated for determination of residual solvents in [{sup 18}F]FDG. Analyses were carried out in a Perkin Elmer gas chromatograph equipped with a flame ionization detector. The separation was obtained on a 0.53-mm x 30 m fused-silica column. Validation included the evaluation of various parameters, such as: specificity, linearity and range, limits of detection and quantitation, precision (repeatability and intermediate precision), accuracy, and robustness. Results were found to be within acceptable limits, indicating the developed procedure is suitable for its intended application. Considering the short half-life of fluorine-18 (109.7 minutes), this new method could be a valuable alternative for routine quality control of [{sup 18}F]FDG. (author)

  6. FPGA Implementation of Uniform Random Number based on Residue Method

    Directory of Open Access Journals (Sweden)

    Zulfikar .

    2014-04-01

    Full Text Available This paper presents the implementation and comparisons of uniform random number on Field Programable Gate Array (FPGA. Uniform random numbers are generated based on residue method. The circuit of generating uniform random number is presented in general view. The circuit is constructed from a multiplexer, a multiplier, buffers and some basic gates. FPGA implementation of the designed circuit has been done into various Xilinx chips. Simulation results are viewed clearly in the paper. Random numbers are generated based on different parameters. Comparisons upon occupied area and maximum frequency from different Xilinx chip are examined. Virtex 7 is the fastest chip and Virtex 4 is the best choice in terms of occupied area. Finally, Uniform random numbers have been generated successfully on FPGA using residue method.Keywords: FPGA implementation, random number, uniform random number, residue method, Xilinx chips

  7. Analytic examination of mechanism for compressive residual stress introduction with low plastic strain using peening

    International Nuclear Information System (INIS)

    Ishibashi, Ryo; Hato, Hisamitsu; Miyazaki, Katsumasa; Yoshikubo, Fujio

    2016-01-01

    Our goal for this study was to understand the cause of the differences in surface properties between surfaces processed using water jet peening (WJP) and shot peening (SP) and to examine the compressive residual stress introduction process with low plastic strain using SP. The dynamic behaviors of stress and strain in surfaces during these processes were analyzed through elasto-plastic calculations using a finite-element method program, and the calculated results were compared with measured results obtained through experiments. Media impacting a surface results in a difference in the hardness and microstructure of the processed surface. During SP, a shot deforms the surface locally with stress concentration in the early stages of the impact, while shock waves deform the surface evenly throughout the wave passage across the surface during WJP. A shot with a larger diameter creates a larger impact area on the surface during shot impact. Thus, SP with a large-diameter shot suppresses the stress concentration under the same kinetic energy condition. As the shot diameter increases, the equivalent plastic strain decreases. On the other hand, the shot is subject to size restriction since the calculated results indicate the compressive residual stress at the surface decreased and occasionally became almost zero as the shot diameter increased. Thus, compressive residual stress introduction with low plastic strain by using SP is considered achievable by using shots with a large diameter and choosing the appropriate peening conditions. (author)

  8. Analytical method for establishing indentation rolling resistance

    Science.gov (United States)

    Gładysiewicz, Lech; Konieczna, Martyna

    2018-01-01

    Belt conveyors are highly reliable machines able to work in special operating conditions. Harsh environment, long distance of transporting and great mass of transported martials are cause of high energy usage. That is why research in the field of belt conveyor transportation nowadays focuses on reducing the power consumption without lowering their efficiency. In this paper, previous methods for testing rolling resistance are described, and new method designed by authors was presented. New method of testing rolling resistance is quite simple and inexpensive. Moreover it allows to conduct the experimental tests of the impact of different parameters on the value of indentation rolling resistance such as core design, cover thickness, ambient temperature, idler travel frequency, or load value as well. Finally results of tests of relationship between rolling resistance and idler travel frequency and between rolling resistance and idler travel speed was presented.

  9. The gravimetric method for the determination of residual moisture in freeze-dried biological products.

    Science.gov (United States)

    May, J C; Wheeler, R M; Grim, E

    1989-06-01

    The gravimetric test for the determination of residual moisture in freeze-dried biological products performed in a humidity- and temperature-controlled room with the use of scrupulous gravimetric analytical technique can be used to accurately determine residual moisture in freeze-dried biological products such as antihemophilic factor (human) or honey bee venom allergenic extract. This method determines the first water of hydration of sodium tartrate dihydrate (7.93%) to within 1.3% of the calculated value with a relative standard deviation of 0.3% for 10 replicates. For this gravimetric procedure, freeze-dried samples containing from 1.12 to 4.4% residual moisture had relative standard deviations ranging from 3.6 to 9.1%. Samples containing less than 1.0% residual moisture by the gravimetric method such as intravenous immune globulin and antihemophilic factor (human) had relative standard deviations ranging from 16.7 to 47.0%. Relative standard deviations for residual moisture tests performed on comparable samples by the Karl Fischer and thermogravimetric methods showed similar variability.

  10. ANALYTICAL METHODS FOR CALCULATING FAN AERODYNAMICS

    Directory of Open Access Journals (Sweden)

    Jan Dostal

    2015-12-01

    Full Text Available This paper presents results obtained between 2010 and 2014 in the field of fan aerodynamics at the Department of Composite Technology at the VZLÚ aerospace research and experimental institute in Prague – Letnany. The need for rapid and accurate methods for the preliminary design of blade machinery led to the creation of a mathematical model based on the basic laws of turbomachine aerodynamics. The mathematical model, the derivation of which is briefly described below, has been encoded in a computer programme, which enables the theoretical characteristics of a fan of the designed geometry to be determined rapidly. The validity of the mathematical model is assessed continuously by measuring model fans in the measuring unit, which was developed and manufactured specifically for this purpose. The paper also presents a comparison between measured characteristics and characteristics determined by the mathematical model as the basis for a discussion on possible causes of measured deviations and calculation deviations.

  11. Residual-based model diagnosis methods for mixture cure models.

    Science.gov (United States)

    Peng, Yingwei; Taylor, Jeremy M G

    2017-06-01

    Model diagnosis, an important issue in statistical modeling, has not yet been addressed adequately for cure models. We focus on mixture cure models in this work and propose some residual-based methods to examine the fit of the mixture cure model, particularly the fit of the latency part of the mixture cure model. The new methods extend the classical residual-based methods to the mixture cure model. Numerical work shows that the proposed methods are capable of detecting lack-of-fit of a mixture cure model, particularly in the latency part, such as outliers, improper covariate functional form, or nonproportionality in hazards if the proportional hazards assumption is employed in the latency part. The methods are illustrated with two real data sets that were previously analyzed with mixture cure models. © 2016, The International Biometric Society.

  12. Smoothing-Norm Preconditioning for Regularizing Minimum-Residual Methods

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Toke Koldborg

    2006-01-01

    take into account a smoothing norm for the solution. This technique is well established for CGLS, but it does not immediately carry over to minimum-residual methods when the smoothing norm is a seminorm or a Sobolev norm. We develop a new technique which works for any smoothing norm of the form $\\|L...

  13. Ceramic residue for producing cements, method for the production thereof, and cements containing same

    OpenAIRE

    Sánchez de Rojas, María Isabel; Frías, Moisés; Asensio, Eloy; Medina Martínez, César

    2014-01-01

    [EN] The invention relates to a ceramic residue produced from construction and demolition residues, as a puzzolanic component of cements. The invention also relates to a method for producing said ceramic residues and to another method of producing cements using said residues. This type of residue is collected in recycling plants, where it is managed. This invention facilitates a potential commercial launch.

  14. Comparative Analytical Methods for the Measurment of Chlorine Dioxide

    OpenAIRE

    Desai, Unmesh Jeetendra

    2002-01-01

    Four commercially available methods used for the analysis of low-level Chlorine Dioxide (ClO2) concentrations in drinking water were evaluated for accuracy and precision and ranked according to cost, efficiency and ease of the methods under several conditions that might be encountered at water treatment plants. The different analytical methods included: 1.The DPD (N, N-diethyl-p-phenylenediamine) method 2.Lissamine Green B (LGB) wet-chemical method 3.Palintest® kit LGB 4.A...

  15. Approximate analytical solution of diffusion equation with fractional time derivative using optimal homotopy analysis method

    Directory of Open Access Journals (Sweden)

    S. Das

    2013-12-01

    Full Text Available In this article, optimal homotopy-analysis method is used to obtain approximate analytic solution of the time-fractional diffusion equation with a given initial condition. The fractional derivatives are considered in the Caputo sense. Unlike usual Homotopy analysis method, this method contains at the most three convergence control parameters which describe the faster convergence of the solution. Effects of parameters on the convergence of the approximate series solution by minimizing the averaged residual error with the proper choices of parameters are calculated numerically and presented through graphs and tables for different particular cases.

  16. Analytical methods for quantitation of prenylated flavonoids from hops

    Science.gov (United States)

    Nikolić, Dejan; van Breemen, Richard B.

    2013-01-01

    The female flowers of hops (Humulus lupulus L.) are used as a flavoring agent in the brewing industry. There is growing interest in possible health benefits of hops, particularly as estrogenic and chemopreventive agents. Among the possible active constituents, most of the attention has focused on prenylated flavonoids, which can chemically be classified as prenylated chalcones and prenylated flavanones. Among chalcones, xanthohumol (XN) and desmethylxanthohumol (DMX) have been the most studied, while among flavanones, 8-prenylnaringenin (8-PN) and 6-prenylnaringenin (6-PN) have received the most attention. Because of the interest in medicinal properties of prenylated flavonoids, there is demand for accurate, reproducible and sensitive analytical methods to quantify these compounds in various matrices. Such methods are needed, for example, for quality control and standardization of hop extracts, measurement of the content of prenylated flavonoids in beer, and to determine pharmacokinetic properties of prenylated flavonoids in animals and humans. This review summarizes currently available analytical methods for quantitative analysis of the major prenylated flavonoids, with an emphasis on the LC-MS and LC-MS-MS methods and their recent applications to biomedical research on hops. This review covers all methods in which prenylated flavonoids have been measured, either as the primary analytes or as a part of a larger group of analytes. The review also discusses methodological issues relating to the quantitative analysis of these compounds regardless of the chosen analytical approach. PMID:24077106

  17. Prediction of residual stress using explicit finite element method

    Directory of Open Access Journals (Sweden)

    W.A. Siswanto

    2015-12-01

    Full Text Available This paper presents the residual stress behaviour under various values of friction coefficients and scratching displacement amplitudes. The investigation is based on numerical solution using explicit finite element method in quasi-static condition. Two different aeroengine materials, i.e. Super CMV (Cr-Mo-V and Titanium alloys (Ti-6Al-4V, are examined. The usage of FEM analysis in plate under normal contact is validated with Hertzian theoretical solution in terms of contact pressure distributions. The residual stress distributions along with normal and shear stresses on elastic and plastic regimes of the materials are studied for a simple cylinder-on-flat contact configuration model subjected to normal loading, scratching and followed by unloading. The investigated friction coefficients are 0.3, 0.6 and 0.9, while scratching displacement amplitudes are 0.05 mm, 0.10 mm and 0.20 mm respectively. It is found that friction coefficient of 0.6 results in higher residual stress for both materials. Meanwhile, the predicted residual stress is proportional to the scratching displacement amplitude, higher displacement amplitude, resulting in higher residual stress. It is found that less residual stress is predicted on Super CMV material compared to Ti-6Al-4V material because of its high yield stress and ultimate strength. Super CMV material with friction coefficient of 0.3 and scratching displacement amplitude of 0.10 mm is recommended to be used in contact engineering applications due to its minimum possibility of fatigue.

  18. Development of quality-by-design analytical methods.

    Science.gov (United States)

    Vogt, Frederick G; Kord, Alireza S

    2011-03-01

    Quality-by-design (QbD) is a systematic approach to drug development, which begins with predefined objectives, and uses science and risk management approaches to gain product and process understanding and ultimately process control. The concept of QbD can be extended to analytical methods. QbD mandates the definition of a goal for the method, and emphasizes thorough evaluation and scouting of alternative methods in a systematic way to obtain optimal method performance. Candidate methods are then carefully assessed in a structured manner for risks, and are challenged to determine if robustness and ruggedness criteria are satisfied. As a result of these studies, the method performance can be understood and improved if necessary, and a control strategy can be defined to manage risk and ensure the method performs as desired when validated and deployed. In this review, the current state of analytical QbD in the industry is detailed with examples of the application of analytical QbD principles to a range of analytical methods, including high-performance liquid chromatography, Karl Fischer titration for moisture content, vibrational spectroscopy for chemical identification, quantitative color measurement, and trace analysis for genotoxic impurities. Copyright © 2010 Wiley-Liss, Inc.

  19. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  20. Analytic methods for field induced tunneling in quantum wells with ...

    Indian Academy of Sciences (India)

    Electric field induced tunneling is studied in three different types of quantum wells by solving time-independent effective mass equation in analytic methods based on three different Airy function approaches. Comparison of different Airy function methods indicates that they are identical and connected to each other by the ...

  1. The MESERAN Method: Rapid Quantification of Non-Volatile Organic Residue (NVOR)

    Energy Technology Data Exchange (ETDEWEB)

    Benkovich, M.G.

    2002-06-13

    The precision analytical technique known as MESERAN Analysis permits quantitative measurement of the level of preexisting nonvolatile organic residue (NVOR) on a substrate from <1 nanogram (ng)/cm{sup 2} to > 100 micrograms ({micro}g)/cm{sup 2} in 2 minutes. MESERAN Analysis is also applicable to determining NVOR in solvents and solvent extracts. The MESERAN method is able to quantify organic contamination levels down to and below 1 ng by depositing as little as 10 microliters ({micro}L) of solvent containing a known amount of contamination on a clean substrate, allowing it to evaporate, and measuring the evaporated residue. The method will be described in detail and NVOR measurements determined from MESERAN data will be presented.

  2. Fuel Cycle Externalities: Analytical Methods and Issues, Report 2

    International Nuclear Information System (INIS)

    Barnthouse, L.W.; Cada, G.F.; Cheng, M.-D.; Easterly, C.E.; Kroodsma, R.L.; Lee, R.; Shriner, D.S.; Tolbert, V.R.; Turner, R.S.

    1994-01-01

    that also have not been fully addressed. This document contains two types of papers that seek to fill part of this void. Some of the papers describe analytical methods that can be applied to one of the five steps of the damage function approach. The other papers discuss some of the complex issues that arise in trying to estimate externalities. This report, the second in a series of eight reports, is part of a joint study by the U.S. Department of Energy (DOE) and the Commission of the European Communities (EC)* on the externalities of fuel cycles. Most of the papers in this report were originally written as working papers during the initial phases of this study. The papers provide descriptions of the (non-radiological) atmospheric dispersion modeling that the study uses; reviews much of the relevant literature on ecological and health effects, and on the economic valuation of those impacts; contains several papers on some of the more complex and contentious issues in estimating externalities; and describes a method for depicting the quality of scientific information that a study uses. The analytical methods and issues that this report discusses generally pertain to more than one of the fuel cycles, though not necessarily to all of them. The report is divided into six parts, each one focusing on a different subject area

  3. Estimating Fuel Cycle Externalities: Analytical Methods and Issues, Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Barnthouse, L.W.; Cada, G.F.; Cheng, M.-D.; Easterly, C.E.; Kroodsma, R.L.; Lee, R.; Shriner, D.S.; Tolbert, V.R.; Turner, R.S.

    1994-07-01

    of complex issues that also have not been fully addressed. This document contains two types of papers that seek to fill part of this void. Some of the papers describe analytical methods that can be applied to one of the five steps of the damage function approach. The other papers discuss some of the complex issues that arise in trying to estimate externalities. This report, the second in a series of eight reports, is part of a joint study by the U.S. Department of Energy (DOE) and the Commission of the European Communities (EC)* on the externalities of fuel cycles. Most of the papers in this report were originally written as working papers during the initial phases of this study. The papers provide descriptions of the (non-radiological) atmospheric dispersion modeling that the study uses; reviews much of the relevant literature on ecological and health effects, and on the economic valuation of those impacts; contains several papers on some of the more complex and contentious issues in estimating externalities; and describes a method for depicting the quality of scientific information that a study uses. The analytical methods and issues that this report discusses generally pertain to more than one of the fuel cycles, though not necessarily to all of them. The report is divided into six parts, each one focusing on a different subject area.

  4. A simple regularization method for stable analytic continuation

    Science.gov (United States)

    Fu, Chu-Li; Dou, Fang-Fang; Feng, Xiao-Li; Qian, Zhi

    2008-12-01

    The problems of analytic continuation are frequently encountered in many practical applications. These problems are well known to be severely ill-posed and therefore several regularization methods have been suggested for solving them. In this paper we consider the problem of analytic continuation of the analytic function f(z) = f(x + iy) on a strip domain \\Omega=\\{z=x+iy\\in {\\bb C}|x\\in{\\bb R},|y|\\leq y_0\\} , where the data are given only on the line y = 0. We use a very simple and convenient method—the Fourier regularization method to solve this problem. Some sharp error estimates between the exact solution and its approximation are given and numerical examples show the method works effectively. The project is supported by the National Natural Science Foundation of China (Nos. 10671085, 10571079 and 10726017).

  5. Proficiency test on the determination of pesticide residues in grapes with multi-residue methods.

    Science.gov (United States)

    Dehouck, Pieter; Grimalt, Susana; Dabrio, Marta; Cordeiro, Fernando; Fiamegos, Yiannis; Robouch, Piotr; Fernández-Alba, Amadeo R; de la Calle, Beatriz

    2015-05-22

    This manuscript presents the results of the International Measurement Evaluation Programme 37 (IMEP-37) study, a proficiency test (PT) which was organised to assess the world-wide performance of food control laboratories on the determination of pesticide residues in grapes. This PT supports the implementation of Regulation (EC) No 396/2005 on maximum residue levels of pesticides in or on food and feed of plant and animal origin. Eighty-one participants reported results, forty from EU Member States and forty-one from outside the EU. The test item was a grape sample spiked with 20 selected pesticides. The results of the participants were rated with z- and zeta (ζ-) scores in accordance with ISO 13528 and ISO 17043. The standard deviation for the proficiency assessment, σˆ, of this PT was set at 25% for the 20 measured pesticides based on previous experience with similar measurands. The results reported to IMEP-37 showed that the participants performed satisfactorily, ranging from 81% (carbendazim) to 97% (azoxystrobin, penconazole, pyrimethanil) of the participating laboratories. However, only 30% of the participants managed to analyze all pesticides satisfactorily. Overall, the performance of the participants in this PT was good but there is room for improvement in the development of multi-residue methods for the simultaneous analysis of a large number of pesticides with an increased accuracy. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Teaching Analytical Method Transfer through Developing and Validating Then Transferring Dissolution Testing Methods for Pharmaceuticals

    Science.gov (United States)

    Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette

    2017-01-01

    Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…

  7. An Analytical Model for CMUTs with Square Multilayer Membranes Using the Ritz Method

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    2016-03-01

    Full Text Available Capacitive micromachined ultrasonic transducer (CMUT multilayer membrane plays an important role in the performance metrics including the transmitting efficiency and the receiving sensitivity. However, there are few studies of the multilayer membranes. Some analytical models simplify the multilayer membrane as monolayer, which results in inaccuracies. This paper presents a new analytical model for CMUTs with multilayer membranes, which can rapidly and accurately predict static deflection and response frequency of the multilayer membrane under external pressures. The derivation is based on the Ritz method and Hamilton’s principle. The mathematical relationships between the external pressure, static deflection, and response frequency are obtained. Relevant residual stress compensation method is derived. The model has been verified for three-layer and double-layer CMUT membranes by comparing its results with finite element method (FEM simulations, experimental data, and other monolayer models that treat CMUTs as monolayer plates/membranes. For three-layer CMUT membranes, the relative errors are ranging from 0.71%–3.51% for the static deflection profiles, and 0.35%–4.96% for the response frequencies, respectively. For the double-layer CMUT membrane, the relative error with residual stress compensation is 4.14% for the central deflection, and −1.17% for the response frequencies, respectively. This proposed analytical model can serve as a reliable reference and an accurate tool for CMUT design and optimization.

  8. Rigid inclusions-Comparison between analytical and numerical methods

    International Nuclear Information System (INIS)

    Gomez Perez, R.; Melentijevic, S.

    2014-01-01

    This paper compares different analytical methods for analysis of rigid inclusions with finite element modeling. First of all, the load transfer in the distribution layer is analyzed for its different thicknesses and different inclusion grids to define the range between results obtained by analytical and numerical methods. The interaction between the soft soil and the inclusion in the estimation of settlements is studied as well. Considering different stiffness of the soft soil, settlements obtained analytical and numerically are compared. The influence of the soft soil modulus of elasticity on the neutral point depth was also performed by finite elements. This depth has a great importance for the definition of the total length of rigid inclusion. (Author)

  9. SPANDOM - source projection analytic nodal discrete ordinates method

    International Nuclear Information System (INIS)

    Kim, Tae Hyeong; Cho, Nam Zin

    1994-01-01

    We describe a new discrete ordinates nodal method for the two-dimensional transport equation. We solve the discrete ordinates equation analytically after the source term is projected and represented in polynomials. The method is applied to two fast reactor benchmark problems and compared with the TWOHEX code. The results indicate that the present method accurately predicts not only multiplication factor but also flux distribution

  10. An analytical software for NAA by using K0-method

    International Nuclear Information System (INIS)

    A Jingye; Chen Da; Tu Jing; Chenweishi; Zhang Wenshou; Wang Daohua

    2003-01-01

    An analytical software has been designed for a personal computer in DOS environment to do reactor NAA by using K 0 -method. The system has functions of radionuclide identification, f and α calculation, K 0 -value calculation, quantitative calculation of elemental concentrations, nuclides' data management, experiment design, computer simulation etc. The analytical methods used in this system include absolute method, relative method and K 0 -method. Using this system, three gamma-ray spectra for NAA of Au, Zr samples and GBW07107 rock standard sample have been analyzed. The analysis results are in agreement with the certified results in the scope of uncertainties and the f and α values at the irradiation site in the UZrH pulse reactor are 36.6 and 0.044 respectively. (author)

  11. Development and validation of an alternative to conventional pretreatment methods for residue analysis of butachlor in water, soil, and rice.

    Science.gov (United States)

    Xue, Jiaying; Jiang, Wenqing; Liu, Fengmao; Zhao, Huiyu; Wang, Suli; Peng, Wei

    2014-01-01

    A rapid and effective alternative analytical method for residues of butachlor in water, soil, and rice was established. The operating variables affecting performance of this method, including different extraction conditions and cleanup adsorbents, were evaluated. The determination of butachlor residues in soil, straw, rice hull, and husked rice was performed using GC/MS after extraction with n-hexane and cleanup with graphite carbon black. The average recoveries ranged from 81.5 to 102.7%, with RSDs of 0.6-7.7% for all of the matrixes investigated. The limits of quantitation were 0.05 mg/kg in water and rice plant, and 0.01 mg/kg in soil, straw, rice hull, and husked rice. A comparison among this proposed method, the conventional liquid-liquid extraction, the Quick, Easy, Cheap, Effective, Rugged, and Safe method, and Soxhlet extraction indicated that this method was more suitable for analyzing butachlor in rice samples. The further validation of the proposed method was carried out by Soxhlet extraction for the determination of butachlor residues in the husked rice samples, and the residue results showed there was no obvious difference obtained from these two methods. Samples from a rice field were found to contain butachlor residues below the maximum residue limits set by China (0.5 mg/kg) and Japan (0.1 mg/kg). The proposed method has a strong potential for application in routine screening and processing of large numbers of samples. This study developed a more effective alternative to the conventional analytical methods for analyzing butachlor residues in various matrixes.

  12. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    Science.gov (United States)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  13. Literature Review on Processing and Analytical Methods for ...

    Science.gov (United States)

    Report The purpose of this report was to survey the open literature to determine the current state of the science regarding the processing and analytical methods currently available for recovery of F. tularensis from water and soil matrices, and to determine what gaps remain in the collective knowledge concerning F. tularensis identification from environmental samples.

  14. Frontier in nanoscale flows fractional calculus and analytical methods

    CERN Document Server

    Lewis, Roland; Liu, Hong-yan

    2014-01-01

    This ebook covers the basic properties of nanoscale flows, and various analytical and numerical methods for nanoscale flows and environmental flows. This ebook is a good reference not only for audience of the journal, but also for various communities in mathematics, nanotechnology and environmental science.

  15. An Analytical Method For The Solution Of Reactor Dynamic Equations

    African Journals Online (AJOL)

    Nigeria Journal of Pure and Applied Physics ... One of the challenges of modelling nuclear reactor dynamics on microcomputers is that of finding robust techniques which guarantee the required level of accuracy and at ... In this paper, an analytical method for the solution of nuclear reactor dynamic equations is presented.

  16. A review of experimental methods for determining residual creep life

    International Nuclear Information System (INIS)

    Bolton, C.J.

    1977-11-01

    Experimental methods available for determining how much creep life remains at a particular time in the high temperature service of a component are reviewed. After a brief consideration of the limitations of stress rupture extrapolation techniques, the application of post-exposure creep testing is considered. Ways of assessing the effect of microstructural degradation on residual life are then reviewed. It is pointed out that while this type of work will be useful for certain materials, there are other materials in which 'mechanical damage' such as cavitation will be more important. Cavitation measurement techniques are therefore reviewed. The report ends with a brief consideration of the use of crack growth measurements in assessing the residual life of cracked components. (author)

  17. Prediction of polymer flooding performance using an analytical method

    International Nuclear Information System (INIS)

    Tan Czek Hoong; Mariyamni Awang; Foo Kok Wai

    2001-01-01

    The study investigated the applicability of an analytical method developed by El-Khatib in polymer flooding. Results from a simulator UTCHEM and experiments were compared with the El-Khatib prediction method. In general, by assuming a constant viscosity polymer injection, the method gave much higher recovery values than the simulation runs and the experiments. A modification of the method gave better correlation, albeit only oil production. Investigation is continuing on modifying the method so that a better overall fit can be obtained for polymer flooding. (Author)

  18. Use of scientometrics to assess nuclear and other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs.

  19. Use of scientometrics to assess nuclear and other analytical methods

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1986-01-01

    Scientometrics involves the use of quantitative methods to investigate science viewed as an information process. Scientometric studies can be useful in ascertaining which methods have been most employed for various analytical determinations as well as for predicting which methods will continue to be used in the immediate future and which appear to be losing favor with the analytical community. Published papers in the technical literature are the primary source materials for scientometric studies; statistical methods and computer techniques are the tools. Recent studies have included growth and trends in prompt nuclear analysis impact of research published in a technical journal, and institutional and national representation, speakers and topics at several IAEA conferences, at modern trends in activation analysis conferences, and at other non-nuclear oriented conferences. Attempts have also been made to predict future growth of various topics and techniques. 13 refs., 4 figs., 17 tabs

  20. Long-Term Prediction of Satellite Orbit Using Analytical Method

    Directory of Open Access Journals (Sweden)

    Jae-Cheol Yoon

    1997-12-01

    Full Text Available A long-term prediction algorithm of geostationary orbit was developed using the analytical method. The perturbation force models include geopotential upto fifth order and degree and luni-solar gravitation, and solar radiation pressure. All of the perturbation effects were analyzed by secular variations, short-period variations, and long-period variations for equinoctial elements such as the semi-major axis, eccentricity vector, inclination vector, and mean longitude of the satellite. Result of the analytical orbit propagator was compared with that of the cowell orbit propagator for the KOREASAT. The comparison indicated that the analytical solution could predict the semi-major axis with an accuarcy of better than ~35meters over a period of 3 month.

  1. Theological Predication, Doctrinal Location, and Method in Analytic Theology

    Directory of Open Access Journals (Sweden)

    Peterson Ryan S.

    2017-09-01

    Full Text Available Theological method is situated properly in relation to a range of doctrinal commitments, especially commitments located in the doctrines of God, creation, and theological anthropology. In this article, I use Thomas Aquinas’s account of theological predication to illustrate this doctrinal and methodological interconnection. Then, I describe the methodological commitments of analytic theology as they have been articulated by its advocates and argue that analytic theology should embrace an explicitly theological methodology. This requires taking seriously the proper ends of theology and the varied means used by theologians in the Christian theological tradition. I argue that analytic theologians should nurture attentiveness to theology’s chief end (the visio Dei and the corresponding goals of faithful worship and personal formation, the doctrinal order in which specific doctrinal questions find their proper context and location (beginning from and ending with the doctrine of God, and the practices that facilitate good theological judgment-making (prayer and contemplation.

  2. Analytical Methods of Decoupling the Automotive Engine Torque Roll Axis

    Science.gov (United States)

    JEONG, TAESEOK; SINGH, RAJENDRA

    2000-06-01

    This paper analytically examines the multi-dimensional mounting schemes of an automotive engine-gearbox system when excited by oscillating torques. In particular, the issue of torque roll axis decoupling is analyzed in significant detail since it is poorly understood. New dynamic decoupling axioms are presented an d compared with the conventional elastic axis mounting and focalization methods. A linear time-invariant system assumption is made in addition to a proportionally damped system. Only rigid-body modes of the powertrain are considered and the chassis elements are assumed to be rigid. Several simplified physical systems are considered and new closed-form solutions for symmetric and asymmetric engine-mounting systems are developed. These clearly explain the design concepts for the 4-point mounting scheme. Our analytical solutions match with the existing design formulations that are only applicable to symmetric geometries. Spectra for all six rigid-body motions are predicted using the alternate decoupling methods and the closed-form solutions are verified. Also, our method is validated by comparing modal solutions with prior experimental and analytical studies. Parametric design studies are carried out to illustrate the methodology. Chief contributions of this research include the development of new or refined analytical models and closed-form solutions along with improved design strategies for the torque roll axis decoupling.

  3. Sampling and analytical methods for atmospheric reduced sulphur compounds

    OpenAIRE

    Cruz, Lícia P. S.; Campos, Vânia P.

    2008-01-01

    This work presents a review of sampling and analytical methods that can be applied to atmospheric traces of reduced sulphur compounds (RSC) in the atmosphere. Sampling methodology involving discontinuous methods with preconcentration is mostly used. For the most part, adsorption on solids and cryogenic capture are applied as a procedure. The analysis of these compounds has been done mainly by gas chromatography with FPD, fluorescence and spectrophotometry. Advantages and disadvantages of the ...

  4. Current analytical methods for plant auxin quantification--A review.

    Science.gov (United States)

    Porfírio, Sara; Gomes da Silva, Marco D R; Peixe, Augusto; Cabrita, Maria J; Azadi, Parastoo

    2016-01-01

    Plant hormones, and especially auxins, are low molecular weight compounds highly involved in the control of plant growth and development. Auxins are also broadly used in horticulture, as part of vegetative plant propagation protocols, allowing the cloning of genotypes of interest. Over the years, large efforts have been put in the development of more sensitive and precise methods of analysis and quantification of plant hormone levels in plant tissues. Although analytical techniques have evolved, and new methods have been implemented, sample preparation is still the limiting step of auxin analysis. In this review, the current methods of auxin analysis are discussed. Sample preparation procedures, including extraction, purification and derivatization, are reviewed and compared. The different analytical techniques, ranging from chromatographic and mass spectrometry methods to immunoassays and electrokinetic methods, as well as other types of detection are also discussed. Considering that auxin analysis mirrors the evolution in analytical chemistry, the number of publications describing new and/or improved methods is always increasing and we considered appropriate to update the available information. For that reason, this article aims to review the current advances in auxin analysis, and thus only reports from the past 15 years will be covered. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A strategy for the evaluation of an analytical approach for selected pesticide residues in complex agricultural product matrices-A case study of leek.

    Science.gov (United States)

    Xu, Yanyan; Song, Ninghui; Zhang, Qin; Liu, Jining; Chen, Guosong; Shi, Lili; Wang, Jikui

    2017-04-15

    In order to choose a sensitive, selective, simple, rapid, cost-effective and reliable analytical method for a given complex sample, a strategy was proposed for the evaluation of an analytical approach to determining multi-pesticide residue in complex agricultural product matrices, using leek as an example. In this work, the matrix effect of most of pesticides were in the range of -50% to -90%. A simple thin layer chromatography (TLC) was used to evaluate the effect of cleanup. The results agree well with that of matrix effect described above. More than 91% of the investigated compounds achieved recoveries were in the range of 70-120%. The limits of detection and limits of quantification were in the range of 0.1-3.5ng/g and 0.4-11.5ng/g, respectively. The strategy can be used to analyze multi-pesticide residue or related chemicals in diverse agricultural product matrices to provide technical guidance in choosing an analytical approach. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. A Semi-Analytical Model for Calculating Touch-Point Pressure and Pull-in Voltage for Clamped Diaphragms with Residual Stress

    Directory of Open Access Journals (Sweden)

    Anurekha SHARMA

    2007-10-01

    Full Text Available A closed form model for evaluating touch point pressure and pull-in voltage of clamped square diaphragm with residual stress is proposed. Square diaphragms are used in numerous applications. The design parameters for all these structures are pull-in voltage and/or touchpoint pressure. The materials employed for fabricating diaphragms for these structures are p+ doped silicon, polysilicon, silicon nitride, polyimide etc. All these materials have residual stress, which influences the behavior of the transducer. In addition to this, a capacitive transducer may or may not employ an intervening layer of dielectric on the fixed electrode. Closed form expressions for evaluating touch-point pressure and pull-in voltage have been derived for such a structure by means of semi-analytical model. The method proposed is less complex and less time consuming in comparison with FEM tools.

  7. Application of the bead flush method to welded pipes to evaluate residual stresses nondestructively

    International Nuclear Information System (INIS)

    Nakamura, H.; Yamamoto, M.

    2002-01-01

    To assess the structural integrity of welded structures during the design and in-service inspection, it is important to evaluate welding residual stresses. Recently, the design process of structures has shifted from 'the design by rule' to 'the design by analysis' using the FEM (finite element method) codes. As the design process advances, analytical processes have formed a link in the chain of manufacturing and in-service inspection procedures. Under this circumstance, authors have proposed a new method called 'the Bead Flush Method', to evaluate the welding residual stresses by utilizing the FEM data constructed during the structural design. In this method, eigenstrains as sources of residual stresses are calculated from released elastic strains after removal of reinforcement of the weld by applying the inverse analysis. Then, residual stresses as well as displacements at any location concerned are evaluated by imposing eigenstrains as initial strains in the FEM analysis. Mechanical properties required through this analysis are the elastic constants at room temperature. No further properties, such as temperature dependencies of the yield strength and the thermal coefficient, are needed. By now, we have confirmed its utility for welded plates by computer simulations and experiments. In this study, further development of this method for application to welded pipes was attempted. Despite its relatively simple shape of pipes (axe symmetrical) compared with welded plates (3-dimentional), welded pipe problems are more complicated than those of welded plates from a view point of the inverse analysis. As a first step, a basic formulization was attempted to overcome this difficulty and future problems to be solved were made clear. Then computer simulations of the bead flush method conducted for a thin walled welded pipe confirmed its utility. Refs. 2 (author)

  8. Analytical Methods for the Quantification of Histamine and Histamine Metabolites.

    Science.gov (United States)

    Bähre, Heike; Kaever, Volkhard

    2017-01-01

    The endogenous metabolite histamine (HA) is synthesized in various mammalian cells but can also be ingested from exogenous sources. It is involved in a plethora of physiological and pathophysiological processes. So far, four different HA receptors (H 1 R-H 4 R) have been described and numerous HAR antagonists have been developed. Contemporary investigations regarding the various roles of HA and its main metabolites have been hampered by the lack of highly specific and sensitive analytic methods for all of these analytes. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) is the method of choice for identification and sensitive quantification of many low-molecular weight endogenous metabolites. In this chapter, different methodological aspects of HA quantification as well as recommendations for LC-MS/MS methods suitable for analysis of HA and its main metabolites are summarized.

  9. Validation of analytical methods based on accuracy profiles.

    Science.gov (United States)

    Feinberg, Max

    2007-07-27

    Validation is a very living field in analytical chemistry as illustrated by the numerous publications addressing this topic. But, there is some ambiguity in this concept and the abundant vocabulary often does not help the analytical chemist. This paper presents a new method based on the fitness-for-purpose approach of the validation. It consists in building a graphical decision-making tool, called the accuracy profile. Using measurements collected under reproducibility or intermediate precision condition, it allows computing an interval where a known proportion of future measurements will be located. When comparing this interval to an acceptability interval defined by the result end-user it is possible to simply decide whether a method is valid or not. The fundamentals of this method are presented starting from an accepted definition of validation. An example of application illustrates how validation can be experimentally organized and conclusion made.

  10. Developments and retrospectives in Lie theory geometric and analytic methods

    CERN Document Server

    Penkov, Ivan; Wolf, Joseph

    2014-01-01

    This volume reviews and updates a prominent series of workshops in representation/Lie theory, and reflects the widespread influence of those  workshops in such areas as harmonic analysis, representation theory, differential geometry, algebraic geometry, and mathematical physics.  Many of the contributors have had leading roles in both the classical and modern developments of Lie theory and its applications. This Work, entitled Developments and Retrospectives in Lie Theory, and comprising 26 articles, is organized in two volumes: Algebraic Methods and Geometric and Analytic Methods. This is the Geometric and Analytic Methods volume. The Lie Theory Workshop series, founded by Joe Wolf and Ivan Penkov and joined shortly thereafter by Geoff Mason, has been running for over two decades. Travel to the workshops has usually been supported by the NSF, and local universities have provided hospitality. The workshop talks have been seminal in describing new perspectives in the field covering broad areas of current re...

  11. FORECASTING PILE SETTLEMENT ON CLAYSTONE USING NUMERICAL AND ANALYTICAL METHODS

    Directory of Open Access Journals (Sweden)

    Ponomarev Andrey Budimirovich

    2016-06-01

    Full Text Available In the article the problem of designing pile foundations on claystones is reviewed. The purpose of this paper is comparative analysis of the analytical and numerical methods for forecasting the settlement of piles on claystones. The following tasks were solved during the study: 1 The existing researches of pile settlement are analyzed; 2 The characteristics of experimental studies and the parameters for numerical modeling are presented, methods of field research of single piles’ operation are described; 3 Calculation of single pile settlement is performed using numerical methods in the software package Plaxis 2D and analytical method according to the requirements SP 24.13330.2011; 4 Experimental data is compared with the results of analytical and numerical calculations; 5 Basing on these results recommendations for forecasting pile settlement on claystone are presented. Much attention is paid to the calculation of pile settlement considering the impacted areas in ground space beside pile and the comparison with the results of field experiments. Basing on the obtained results, for the prediction of settlement of single pile on claystone the authors recommend using the analytical method considered in SP 24.13330.2011 with account for the impacted areas in ground space beside driven pile. In the case of forecasting the settlement of single pile on claystone by numerical methods in Plaxis 2D the authors recommend using the Hardening Soil model considering the impacted areas in ground space beside the driven pile. The analyses of the results and calculations are presented for examination and verification; therefore it is necessary to continue the research work of deep foundation at another experimental sites to improve the reliability of the calculation of pile foundation settlement. The work is of great interest for geotechnical engineers engaged in research, design and construction of pile foundations.

  12. Analysis Method for Pesticides Residues by GC/MS in Lebanese Apple

    International Nuclear Information System (INIS)

    Jaber, F.; Al Iskandarani, M.

    2008-01-01

    The apple's crop can be affected by many pests during the growing season, which requires careful monitoring. Both apple fruit and apple tree need to be treated by pesticides in order to protect them from pests. Such treatment often leads to the accumulation of stable pesticides inside the fruit. The local market provides a large variety of pesticides allowing farmers to use more than one active substance in order to protect their crop, often without proper advice. Monitoring pesticides on apples and other agricultural crops is the best way to protect consumers health from the hazards of pesticides residues. The development of new, rapid and effective method to analyze the multi pesticides residues at trace levels in apple samples is essential. This work describes the extraction procedure and the analytical method developed to detect the pesticide residues using the gas-chromatographic-mass spectrometric approach (GC-MS). The developed method was successfully applied to analyze apple samples collected from different Lebanese markets for a one year period in order to monitor the presence of pesticides and their stability in apple fruits during storage. (author)

  13. Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.

    Science.gov (United States)

    Lehotay, Steven J; Mastovská, Katerina; Yun, Seon Jong

    2005-01-01

    Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.

  14. Customizing computational methods for visual analytics with big data.

    Science.gov (United States)

    Choo, Jaegul; Park, Haesun

    2013-01-01

    The volume of available data has been growing exponentially, increasing data problem's complexity and obscurity. In response, visual analytics (VA) has gained attention, yet its solutions haven't scaled well for big data. Computational methods can improve VA's scalability by giving users compact, meaningful information about the input data. However, the significant computation time these methods require hinders real-time interactive visualization of big data. By addressing crucial discrepancies between these methods and VA regarding precision and convergence, researchers have proposed ways to customize them for VA. These approaches, which include low-precision computation and iteration-level interactive visualization, ensure real-time interactive VA for big data.

  15. Field sampling and selecting on-site analytical methods for explosives in soil

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, A.B.; Craig, H.D.; Jenkins, T.F.; Sisk, W.E.

    1996-12-01

    A large number of defense-related sites are contaminated with elevated levels of secondary explosives. Levels of contamination range from barely detectable to levels above 10% that need special handling because of the detonation potential. Characterization of explosives-contaminated sites is particularly difficult because of the very heterogeneous distribution of contamination in the environment and within samples. To improve site characterization, several options exist including collecting more samples, providing on-site analytical data to help direct the investigation, compositing samples, improving homogenization of the samples, and extracting larger samples. This publication is intended to provide guidance to Remedial Project Managers regarding field sampling and on-site analytical methods for detecting and quantifying secondary explosive compounds in soils, and is not intended to include discussions of the safety issues associated with sites contaminated with explosive residues.

  16. OVERVIEW OF VALIDATION, BASIC CONCEPTS AND ANALYTICAL METHOD PROCESS VALIDATION

    OpenAIRE

    Indu Gurram* , M.V.S.Kavitha, M.V.Nagabhushnam, Brahmaiah Bonthagara, D.Nagarjuna Reddy

    2017-01-01

    Quality is the primordial intention to any industry and its products manufactured. Multiple views on obtaining such quality are the current interest in the pharmaceutical industry. Validation is the art of designing and practicing the designed steps alongside with the documentation. Validation and quality assurance will go hand in hand, ensuring the through quality for the products. When analytical method is utilized to generate results about the characteristics of drug related samples it is ...

  17. Deamidation of asparagine and glutamine residues in proteins and peptides: structural determinants and analytical methodology

    NARCIS (Netherlands)

    Bischoff, Rainer; Kolbe, H.V.

    1994-01-01

    Non-enzymatic deamidation of asparagine and glutamine residues in proteins and peptides are reviewed by first outlining the well-described reaction mechanism involving cyclic imide intermediates, followed by a discussion of structural features which influence the reaction rate. The second and major

  18. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, Chris; Little, Mike; Huang, Thomas; Jacob, Joseph; Yang, Phil; Kuo, Kwo-Sen

    2016-01-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based file systems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  19. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, C.; Little, M. M.; Huang, T.; Jacob, J. C.; Yang, C. P.; Kuo, K. S.

    2016-12-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based filesystems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  20. Analytical method to determine flexoelectric coupling coefficient at nanoscale

    Science.gov (United States)

    Zhou, Hao; Pei, Yongmao; Hong, Jiawang; Fang, Daining

    2016-03-01

    Flexoelectricity is defined as the coupling between the strain gradient and polarization, which is expected to be remarkable at nanoscale. However, measuring the flexoelectricity at nanoscale is challenging. In the present work, an analytical method for measuring the flexoelectric coupling coefficient based on nanocompression technique is proposed. It is found that the flexoelectricity can induce stiffness softening of the dielectric nano-cone-frustum. This phenomenon becomes more significant when the sample size decreases or the half cone angle increases. This method avoids measuring the electric polarization or current at nanoscale with dynamical loading, which can be beneficial to the flexoelectric measurement at nanoscale and design of flexoelectric nanodevices.

  1. Comparison of analytical methods for calculation of wind loads

    Science.gov (United States)

    Minderman, Donald J.; Schultz, Larry L.

    1989-01-01

    The following analysis is a comparison of analytical methods for calculation of wind load pressures. The analytical methods specified in ASCE Paper No. 3269, ANSI A58.1-1982, the Standard Building Code, and the Uniform Building Code were analyzed using various hurricane speeds to determine the differences in the calculated results. The winds used for the analysis ranged from 100 mph to 125 mph and applied inland from the shoreline of a large open body of water (i.e., an enormous lake or the ocean) a distance of 1500 feet or ten times the height of the building or structure considered. For a building or structure less than or equal to 250 feet in height acted upon by a wind greater than or equal to 115 mph, it was determined that the method specified in ANSI A58.1-1982 calculates a larger wind load pressure than the other methods. For a building or structure between 250 feet and 500 feet tall acted upon by a wind rangind from 100 mph to 110 mph, there is no clear choice of which method to use; for these cases, factors that must be considered are the steady-state or peak wind velocity, the geographic location, the distance from a large open body of water, and the expected design life and its risk factor.

  2. Analytical Methods for Mycotoxin Detection in Southeast Asian Nations (ASEAN).

    Science.gov (United States)

    Lim, Chee Wei; Chung, Gerald; Chan, Sheot Harn

    2017-10-03

    Aflatoxins B 1 (AFB 1 ) and B₂ (AFB₂) and G 1 and G₂ remain the top mycotoxins routinely analyzed and monitored by Association of Southeast Asian Nations (ASEAN) national laboratories primarily for food safety regulation in the major food commodities, nuts and spices. LC tandem fluorescence detection (LC–fluorescence) represents a current mainstream analytical method, with a progressive migration to a primary method by LC tandem MS (MS/MS) for the next half decade. Annual proficiency testing (PT) is conducted by ASEAN Food Reference Laboratories (AFRLs) for mycotoxin testing as part of capability building in national laboratories, with the scope of PT materials spanning from naturally mycotoxin-contaminated spices and nuts in the early 2010s to the recent contamination of corn flour in 2017 for total aflatoxin assay development. The merits of the mainstream LC–fluorescence method are witnessed by a significant improvement ( P < 0.05) in PT z -score passing rates (≤2) from 11.8 to 79.2% for AFB 1 , 23.5 to 83.3% for AFB₂, and 23.5 to 79.2% for total aflatoxins in the last 5 years. This paper discusses the journey of ASEAN national laboratories in analytical testing through AFRLs, and the progressive collective adoption of a multimycotoxin LC-MS/MS method aided by an isotopic dilution assay as a future primary method for safer food commodities.

  3. Minimal Residual Disease Assessment in Lymphoma: Methods and Applications.

    Science.gov (United States)

    Herrera, Alex F; Armand, Philippe

    2017-12-01

    Standard methods for disease response assessment in patients with lymphoma, including positron emission tomography and computed tomography scans, are imperfect. In other hematologic malignancies, particularly leukemias, the ability to detect minimal residual disease (MRD) is increasingly influencing treatment paradigms. However, in many subtypes of lymphoma, the application of MRD assessment techniques, like flow cytometry or polymerase chain reaction-based methods, has been challenging because of the absence of readily detected circulating disease or canonic chromosomal translocations. Newer MRD detection methods that use next-generation sequencing have yielded promising results in a number of lymphoma subtypes, fueling the hope that MRD detection may soon be applicable in clinical practice for most patients with lymphoma. MRD assessment can provide real-time information about tumor burden and response to therapy, noninvasive genomic profiling, and monitoring of clonal dynamics, allowing for many possible applications that could significantly affect the care of patients with lymphoma. Further validation of MRD assessment methods, including the incorporation of MRD assessment into clinical trials in patients with lymphoma, will be critical to determine how best to deploy MRD testing in routine practice and whether MRD assessment can ultimately bring us closer to the goal of personalized lymphoma care. In this review article, we describe the methods available for detecting MRD in patients with lymphoma and their relative advantages and disadvantages. We discuss preliminary results supporting the potential applications for MRD testing in the care of patients with lymphoma and strategies for including MRD assessment in lymphoma clinical trials.

  4. Economic methods for the utilisation of logging residues

    Directory of Open Access Journals (Sweden)

    Gałęzia Tomasz

    2016-03-01

    Full Text Available There are several ways of using logging residues, and the two most common ones in the State Forests are wood chip production for energy purposes by mobile machinery and crushing by tractor-powered crushers. In this research, an economy-based approach was used to compare these methods and assess whether chip production is superior to crushing for clearing a felling area. The average revenues from the sale of wood biomass in the form of wood chips and the average costs of crushing in the Pomorze Forest District were analysed for the period from January 2012 until June 2014. Both revenues and costs (such as fuel, operator’s wage, piling costs, depreciation, insurance and garaging costs were extracted from the State Forests’ database using data-mining software.

  5. An interactive website for analytical method comparison and bias estimation.

    Science.gov (United States)

    Bahar, Burak; Tuncel, Ayse F; Holmes, Earle W; Holmes, Daniel T

    2017-12-01

    Regulatory standards mandate laboratories to perform studies to ensure accuracy and reliability of their test results. Method comparison and bias estimation are important components of these studies. We developed an interactive website for evaluating the relative performance of two analytical methods using R programming language tools. The website can be accessed at https://bahar.shinyapps.io/method_compare/. The site has an easy-to-use interface that allows both copy-pasting and manual entry of data. It also allows selection of a regression model and creation of regression and difference plots. Available regression models include Ordinary Least Squares, Weighted-Ordinary Least Squares, Deming, Weighted-Deming, Passing-Bablok and Passing-Bablok for large datasets. The server processes the data and generates downloadable reports in PDF or HTML format. Our website provides clinical laboratories a practical way to assess the relative performance of two analytical methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. A nonlinear analytic function expansion nodal method for transient calculations

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Han Gyn; Park, Sang Yoon; Cho, Byung Oh; Zee, Sung Quun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation of the solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized, In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of application to the NEACRP PWR rod ejection benchmark problems. 6 refs., 2 figs., 1 tab. (Author)

  7. Analytical methods for toxic gases from thermal degradation of polymers

    Science.gov (United States)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  8. Evolution of microbiological analytical methods for dairy industry needs

    Directory of Open Access Journals (Sweden)

    Daniele eSohier

    2014-02-01

    Full Text Available Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that PCR-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.

  9. Reducing waste generation and radiation exposure by analytical method modification

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.A.

    1996-10-01

    The primary goal of an analytical support laboratory has traditionally been to provide accurate data in a timely and cost effective fashion. Added to this goal is now the need to provide the same high quality data while generating as little waste as possible. At the Savannah River Technology Center (SRTC), we have modified and reengineered several methods to decrease generated waste and hence reduce radiation exposure. These method changes involved improving detection limits (which decreased the amount of sample required for analysis), decreasing reaction and analysis time, decreasing the size of experimental set-ups, recycling spent solvent and reagents, and replacing some methods. These changes had the additional benefits of reducing employee radiation exposure and exposure to hazardous chemicals. In all cases, the precision, accuracy, and detection limits were equal to or better than the replaced method. Most of the changes required little or no expenditure of funds. This paper describes these changes and discusses some of their applications.

  10. ANALYTICAL METHODS FOR KINETIC STUDIES OF BIOLOGICAL INTERACTIONS: A REVIEW

    Science.gov (United States)

    Zheng, Xiwei; Bi, Cong; Li, Zhao; Podariu, Maria; Hage, David S.

    2015-01-01

    The rates at which biological interactions occur can provide important information concerning the mechanism and behavior of these processes in living systems. This review discusses several analytical methods that can be used to examine the kinetics of biological interactions. These techniques include common or traditional methods such as stopped-flow analysis and surface plasmon resonance spectroscopy, as well as alternative methods based on affinity chromatography and capillary electrophoresis. The general principles and theory behind these approaches are examined, and it is shown how each technique can be utilized to provide information on the kinetics of biological interactions. Examples of applications are also given for each method. In addition, a discussion is provided on the relative advantages or potential limitations of each technique regarding its use in kinetic studies. PMID:25700721

  11. Selectivity in analytical chemistry: two interpretations for univariate methods.

    Science.gov (United States)

    Dorkó, Zsanett; Verbić, Tatjana; Horvai, George

    2015-01-01

    Selectivity is extremely important in analytical chemistry but its definition is elusive despite continued efforts by professional organizations and individual scientists. This paper shows that the existing selectivity concepts for univariate analytical methods broadly fall in two classes: selectivity concepts based on measurement error and concepts based on response surfaces (the response surface being the 3D plot of the univariate signal as a function of analyte and interferent concentration, respectively). The strengths and weaknesses of the different definitions are analyzed and contradictions between them unveiled. The error based selectivity is very general and very safe but its application to a range of samples (as opposed to a single sample) requires the knowledge of some constraint about the possible sample compositions. The selectivity concepts based on the response surface are easily applied to linear response surfaces but may lead to difficulties and counterintuitive results when applied to nonlinear response surfaces. A particular advantage of this class of selectivity is that with linear response surfaces it can provide a concentration independent measure of selectivity. In contrast, the error based selectivity concept allows only yes/no type decision about selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Higher geometry an introduction to advanced methods in analytic geometry

    CERN Document Server

    Woods, Frederick S

    2005-01-01

    For students of mathematics with a sound background in analytic geometry and some knowledge of determinants, this volume has long been among the best available expositions of advanced work on projective and algebraic geometry. Developed from Professor Woods' lectures at the Massachusetts Institute of Technology, it bridges the gap between intermediate studies in the field and highly specialized works.With exceptional thoroughness, it presents the most important general concepts and methods of advanced algebraic geometry (as distinguished from differential geometry). It offers a thorough study

  13. Analytical Method to Estimate the Complex Permittivity of Oil Samples

    Directory of Open Access Journals (Sweden)

    Lijuan Su

    2018-03-01

    Full Text Available In this paper, an analytical method to estimate the complex dielectric constant of liquids is presented. The method is based on the measurement of the transmission coefficient in an embedded microstrip line loaded with a complementary split ring resonator (CSRR, which is etched in the ground plane. From this response, the dielectric constant and loss tangent of the liquid under test (LUT can be extracted, provided that the CSRR is surrounded by such LUT, and the liquid level extends beyond the region where the electromagnetic fields generated by the CSRR are present. For that purpose, a liquid container acting as a pool is added to the structure. The main advantage of this method, which is validated from the measurement of the complex dielectric constant of olive and castor oil, is that reference samples for calibration are not required.

  14. Analytical method of spectra calculations in the Bargmann representation

    Energy Technology Data Exchange (ETDEWEB)

    Maciejewski, Andrzej J., E-mail: maciejka@astro.ia.uz.zgora.pl [J. Kepler Institute of Astronomy, University of Zielona Góra, Licealna 9, PL-65-417 Zielona Góra (Poland); Przybylska, Maria, E-mail: M.Przybylska@if.uz.zgora.pl [Institute of Physics, University of Zielona Góra, Licealna 9, 65-417 Zielona Góra (Poland); Stachowiak, Tomasz, E-mail: stachowiak@cft.edu.pl [Center for Theoretical Physics PAS, Al. Lotnikow 32/46, 02-668 Warsaw (Poland)

    2014-10-24

    We formulate a universal method for solving an arbitrary quantum system which, in the Bargmann representation, is described by a system of linear equations with one independent variable, such as one- and multi-photon Rabi models, or N level systems interacting with a single mode of the electromagnetic field and their various generalizations. We explain three types of conditions that determine the spectrum and show their usage for two deformations of the Rabi model. We prove that the spectra of both models are just zeros of transcendental functions, which in one case are given explicitly in terms of confluent Heun functions. - Highlights: • Analytical method of spectrum determination in Bargmann representation is proposed. • Three types of conditions determining spectrum are identified. • Method to two generalizations of the Rabi system is applied.

  15. Analytical description of generation of the residual current density in the plasma produced by a few-cycle laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Silaev, A. A., E-mail: silaev@appl.sci-nnov.ru; Vvedenskii, N. V., E-mail: vved@appl.sci-nnov.ru [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod 603950 (Russian Federation); University of Nizhny Novgorod, Nizhny Novgorod 603950 (Russian Federation)

    2015-05-15

    When a gas is ionized by a few-cycle laser pulse, some residual current density (RCD) of free electrons remains in the produced plasma after the passage of the laser pulse. This quasi-dc RCD is an initial impetus to plasma polarization and excitation of the plasma oscillations which can radiate terahertz (THz) waves. In this work, the analytical model for calculation of RCD excited by a few-cycle laser pulse is developed for the first time. The dependences of the RCD on the carrier-envelope phase (CEP), wavelength, duration, and intensity of the laser pulse are derived. It is shown that maximum RCD corresponding to optimal CEP increases with the laser pulse wavelength, which indicates the prospects of using mid-infrared few-cycle laser pulses in the schemes of generation of high-power THz pulses. Analytical formulas for optimal pulse intensity and maximum efficiency of excitation of the RCD are obtained. Basing on numerical solution of the 3D time-dependent Schrödinger equation for hydrogen atoms, RCD dependence on CEP is calculated in a wide range of wavelengths. High accuracy of analytical formulas is demonstrated at the laser pulse parameters which correspond to the tunneling regime of ionization.

  16. Residual-driven online generalized multiscale finite element methods

    KAUST Repository

    Chung, Eric T.

    2015-09-08

    The construction of local reduced-order models via multiscale basis functions has been an area of active research. In this paper, we propose online multiscale basis functions which are constructed using the offline space and the current residual. Online multiscale basis functions are constructed adaptively in some selected regions based on our error indicators. We derive an error estimator which shows that one needs to have an offline space with certain properties to guarantee that additional online multiscale basis function will decrease the error. This error decrease is independent of physical parameters, such as the contrast and multiple scales in the problem. The offline spaces are constructed using Generalized Multiscale Finite Element Methods (GMsFEM). We show that if one chooses a sufficient number of offline basis functions, one can guarantee that additional online multiscale basis functions will reduce the error independent of contrast. We note that the construction of online basis functions is motivated by the fact that the offline space construction does not take into account distant effects. Using the residual information, we can incorporate the distant information provided the offline approximation satisfies certain properties. In the paper, theoretical and numerical results are presented. Our numerical results show that if the offline space is sufficiently large (in terms of the dimension) such that the coarse space contains all multiscale spectral basis functions that correspond to small eigenvalues, then the error reduction by adding online multiscale basis function is independent of the contrast. We discuss various ways computing online multiscale basis functions which include a use of small dimensional offline spaces.

  17. Measuring multiple residual-stress components using the contour method and multiple cuts

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Michael B [Los Alamos National Laboratory; Swenson, Hunter [Los Alamos National Laboratory; Pagliaro, Pierluigi [U. PALERMO; Zuccarello, Bernardo [U. PALERMO

    2009-01-01

    The conventional contour method determines one component of stress over the cross section of a part. The part is cut into two, the contour of the exposed surface is measured, and Bueckner's superposition principle is analytically applied to calculate stresses. In this paper, the contour method is extended to the measurement of multiple stress components by making multiple cuts with subsequent applications of superposition. The theory and limitations are described. The theory is experimentally tested on a 316L stainless steel disk with residual stresses induced by plastically indenting the central portion of the disk. The stress results are validated against independent measurements using neutron diffraction. The theory has implications beyond just multiple cuts. The contour method measurements and calculations for the first cut reveal how the residual stresses have changed throughout the part. Subsequent measurements of partially relaxed stresses by other techniques, such as laboratory x-rays, hole drilling, or neutron or synchrotron diffraction, can be superimposed back to the original state of the body.

  18. The evolution of analytical chemistry methods in foodomics.

    Science.gov (United States)

    Gallo, Monica; Ferranti, Pasquale

    2016-01-08

    The methodologies of food analysis have greatly evolved over the past 100 years, from basic assays based on solution chemistry to those relying on the modern instrumental platforms. Today, the development and optimization of integrated analytical approaches based on different techniques to study at molecular level the chemical composition of a food may allow to define a 'food fingerprint', valuable to assess nutritional value, safety and quality, authenticity and security of foods. This comprehensive strategy, defined foodomics, includes emerging work areas such as food chemistry, phytochemistry, advanced analytical techniques, biosensors and bioinformatics. Integrated approaches can help to elucidate some critical issues in food analysis, but also to face the new challenges of a globalized world: security, sustainability and food productions in response to environmental world-wide changes. They include the development of powerful analytical methods to ensure the origin and quality of food, as well as the discovery of biomarkers to identify potential food safety problems. In the area of nutrition, the future challenge is to identify, through specific biomarkers, individual peculiarities that allow early diagnosis and then a personalized prognosis and diet for patients with food-related disorders. Far from the aim of an exhaustive review of the abundant literature dedicated to the applications of omic sciences in food analysis, we will explore how classical approaches, such as those used in chemistry and biochemistry, have evolved to intersect with the new omics technologies to produce a progress in our understanding of the complexity of foods. Perhaps most importantly, a key objective of the review will be to explore the development of simple and robust methods for a fully applied use of omics data in food science. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Analytic moment method calculations of the drift wave spectrum

    International Nuclear Information System (INIS)

    Thayer, D.R.; Molvig, K.

    1985-11-01

    A derivation and approximate solution of renormalized mode coupling equations describing the turbulent drift wave spectrum is presented. Arguments are given which indicate that a weak turbulence formulation of the spectrum equations fails for a system with negative dissipation. The inadequacy of the weak turbulence theory is circumvented by utilizing a renormalized formation. An analytic moment method is developed to approximate the solution of the nonlinear spectrum integral equations. The solution method employs trial functions to reduce the integral equations to algebraic equations in basic parameters describing the spectrum. An approximate solution of the spectrum equations is first obtained for a mode dissipation with known solution, and second for an electron dissipation in the NSA

  20. Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms

    CERN Document Server

    Williams, J J

    2013-01-01

    Modern design methods of Automotive Cam Design require the computation of a range of parameters. This book provides a logical sequence of steps for the derivation of the relevant equations from first principles, for the more widely used cam mechanisms. Although originally derived for use in high performance engines, this work is equally applicable to the design of mass produced automotive and other internal combustion engines.   Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms provides the equations necessary for the design of cam lift curves with an associated smooth acceleration curve. The equations are derived for the kinematics and kinetics of all the mechanisms considered, together with those for cam curvature and oil entrainment velocity. This permits the cam shape, all loads, and contact stresses to be evaluated, and the relevant tribology to be assessed. The effects of asymmetry on the manufacture of cams for finger follower and offset translating curved followers is ...

  1. Potentialities and possible applications of a new analytical method (PIXE)

    International Nuclear Information System (INIS)

    Pinho, A.G. de; Montenegro, E.C.; Barros Leite, C.V. de; Baptista, G.B.; Paschoa, A.S.

    1979-01-01

    In 1970, a new method was introduced for trace analysis, namely, the X-ray emission induced by charged particles (PIXE). It has been shown that when protons in the few MeV range are used for the excitation of inner shell electrons and solid state detectors for the detection of the characteristic X-rays, we dispose of a powerful multi-elemental analytical tool of high sensitivity. In contrast to activation spectrometry, this is an in beam technique, irradiation and measuring being performed at the same time. The foundations of the method are described experimental arrangements and problems related to beam transport, target preparation an spectrum analysis. A detailed discussion on precision, accuracy and sensitivity is presented. Applications in biology, medicine, environmental and materials sciences are discussed. (Author) [pt

  2. Analytical methods validation of processes control in injectable antitumor agents

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad Margarita; Cunill Semanat, Edel; Cartaya Morales, Mayra; Diaz de Arma, Anyisela; Curbelo Fonte, Yusleydis

    2010-01-01

    Alternative analytical methods were validated for the process control of 500 mg florouacil, 50 mg doxorrubicin and 50 mg methotrexate by spectrophotometry because of they are more simple and economic allowint to control the drugs quality in process analysis control. Calibration curves of fluorouracil, doxorrubicin and methotrexate were plotted in interval from 60 to 140%, where there were linear with correlation coefficients similar to 0.9998, 0.9999 and 0.9999, respectively; statistical text for intercept and slope were considered as non-significant. Recoveries of 99.97, 99.98 and 99.35% were achieved, respectively in study concentration interval and Cochran and t-Student tests were also non-significant. Methods were specific, linear, precises and exacts in interval of study concentrations

  3. GenoSets: visual analytic methods for comparative genomics.

    Directory of Open Access Journals (Sweden)

    Aurora A Cain

    Full Text Available Many important questions in biology are, fundamentally, comparative, and this extends to our analysis of a growing number of sequenced genomes. Existing genomic analysis tools are often organized around literal views of genomes as linear strings. Even when information is highly condensed, these views grow cumbersome as larger numbers of genomes are added. Data aggregation and summarization methods from the field of visual analytics can provide abstracted comparative views, suitable for sifting large multi-genome datasets to identify critical similarities and differences. We introduce a software system for visual analysis of comparative genomics data. The system automates the process of data integration, and provides the analysis platform to identify and explore features of interest within these large datasets. GenoSets borrows techniques from business intelligence and visual analytics to provide a rich interface of interactive visualizations supported by a multi-dimensional data warehouse. In GenoSets, visual analytic approaches are used to enable querying based on orthology, functional assignment, and taxonomic or user-defined groupings of genomes. GenoSets links this information together with coordinated, interactive visualizations for both detailed and high-level categorical analysis of summarized data. GenoSets has been designed to simplify the exploration of multiple genome datasets and to facilitate reasoning about genomic comparisons. Case examples are included showing the use of this system in the analysis of 12 Brucella genomes. GenoSets software and the case study dataset are freely available at http://genosets.uncc.edu. We demonstrate that the integration of genomic data using a coordinated multiple view approach can simplify the exploration of large comparative genomic data sets, and facilitate reasoning about comparisons and features of interest.

  4. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  6. A method to determine residue levels of persistent organochlorine pesticides in human milk from Indonesian women.

    Science.gov (United States)

    Burke, Emma R; Holden, Alexis J; Shaw, Ian C

    2003-01-01

    A method has been developed for the analysis of organochlorine pesticides in human milk using solvent extraction, Florisil solid phase extraction clean-up and analysis by gas chromatography with an electron capture detector. The recovery of analytes from spiked milk samples was in the range 53 +/- 1% to 109 +/- 7% (n = 9). A small number of samples were obtained from women in a rural and an urban area of Indonesia and analysed using the developed method. The results are reported on a milk fat basis. All samples contained detectable residues of p,p'-DDT (urban mean 0.11 +/- 0.18 mgkg(-1) (n = 5), rural mean 0.07 +/- 0.03 mg kg(-1) (n = 5)) and p,p'-DDE (urban mean 0.05 +/- 0.04 m kg(-1) (n = 5), rural mean 0.76 +/- 1.46 mg kg(-1) (n = 5)). Residues of HCB, betaHCH, alpha-endosulfan and dieldrin were also detected in some samples. There was no significant difference (at the 95% confidence level) in levels of pesticides between urban and rural areas. The levels of organochlorine pesticides in milk from Indonesian women were lower than those reported from Indonesian women exposed to DDT through malaria eradication schemes and were similar to levels reported from UK and Japan.

  7. Comparison and evaluation of two methods for the pesticide residue analysis of organophosphates in yerba mate

    Directory of Open Access Journals (Sweden)

    Lucía Pareja

    Full Text Available Abstract Microwave Assisted Extraction and a modified CEN-QuEChERS methodology were evaluated as extraction and clean up procedures for the simultaneous analysis of 42 organophosphate pesticides in yerba mate (Ilex paraguaiensis. The obtained extracts were analyzed by gas chromatography using a flame photometric detector. Linearity, recovery percentages, relative standard deviations, detection and quantification limits and matrix effects were determined according to DG-SANCO guidelines for both methods. At 0.2 and 0.5 mg/kg the evaluated methods showed percentages recoveries between 70 and 120% for most of the analytes. Using Microwave Assisted Extraction methodology, 33 pesticide residues could be properly analyzed whereas only 27 could be determined with the proposed modified QuEChERS. All relative standard deviation were below 18% except for omethoate and disulfoton sulfone when evaluated by the modified QuEChERS. The limits of detection in both methodologies were 0.2 mg/kg for most of the analyzed compounds. The average detection limit for QuEChERS was 0.04 mg/kg. For 19 of the analytes determined through Microwave Assisted Extraction the lowest validated level were 0.004 mg/kg. Signal suppression/enhancement was observed for most of the pesticides, thus matrix-matched calibration curves were used for quantification. The Microwave Assisted Extraction and QuEChERS procedures studied could detect the organophosphate pesticides above the MRL fixed for "mate" by the European Union. They have been successfully applied for the determination of organophosphate pesticide residues in commercial samples and the positives were confirmed through GC–(ITD-MS.

  8. USING ANALYTIC HIERARCHY PROCESS (AHP METHOD IN RURAL DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Tülay Cengiz

    2003-04-01

    Full Text Available Rural development is a body of economical and social policies towards improving living conditions in rural areas through enabling rural population to utilize economical, social, cultural and technological blessing of city life in place, without migrating. As it is understood from this description, rural development is a very broad concept. Therefore, in development efforts problem should be stated clearly, analyzed and many criterias should be evaluated by experts. Analytic Hierarchy Process (AHP method can be utilized at there stages of development efforts. AHP methods is one of multi-criteria decision method. After degrading a problem in smaller pieces, relative importance and level of importance of two compared elements are determined. It allows evaluation of quality and quantity factors. At the same time, it permits utilization of ideas of many experts and use them in decision process. Because mentioned features of AHP method, it could be used in rural development works. In this article, cultural factors, one of the important components of rural development is often ignored in many studies, were evaluated as an example. As a result of these applications and evaluations, it is concluded that AHP method could be helpful in rural development efforts.

  9. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    Analytical Method of Auxiliary Sources solutions for plane wave scattering by circular impedance cylinders are derived by transformation of the exact eigenfunction series solutions employing the Hankel function wave transformation. The analytical Method of Auxiliary Sources solution thus obtained...

  10. Residual stress measurement of welding area by neutron diffraction method

    International Nuclear Information System (INIS)

    Suzuki, Tamaki; Sugiyama, Masaaki; Oikawa, Hatsuhiko; Nose, Tetsuro; Imafuku, Muneyuki; Tomota, Yo; Suzuki, Hiroshi; Moriai, Atsushi

    2010-01-01

    Resistance spot welding technique is extensively applied to join the body steel sheets in the manufacturing process for the automobile industry. It is known that the fatigue crack initiates occasionally inside of the spot-welded zone in this material, which is a serious issue of the fatigue life. Although this phenomenon is supposed to be related to internal residual stress, the actual residual stress distribution inside of the spot-welded zone is not clear up to now. In this study, a neutron diffraction residual stress measurement technique with well-defined sub-mm 3 square gauge volume is applied in order to clarify the internal three dimensional residual stress distribution just below the spot-welded part of the steel sheets. (author)

  11. Three residual income valuation methods and discounted cash flow valuation

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    In this paper we show that the three residual Income models for equity valuation always yield the same value as the Discounted Cash Flow Valuation models. We use three residual income measures: Economic Profit, Economic Value Added (EVA) and Cash Value Added. We also show that economic profit and EVA are different, although Copeland, Koller and Murrin (2000, page 55) say that economic profit is a synonym of EVA. Specifically, we first show that the present value of the Economic Profit discoun...

  12. Computational and analytical methods in nonlinear fluid dynamics

    Science.gov (United States)

    Walker, James

    1993-09-01

    The central focus of the program was on the application and development of modern analytical and computational methods to the solution of nonlinear problems in fluid dynamics and reactive gas dynamics. The research was carried out within the Division of Engineering Mathematics in the Department of Mechanical Engineering and Mechanics and principally involved Professors P.A. Blythe, E. Varley and J.D.A. Walker. In addition. the program involved various international collaborations. Professor Blythe completed work on reactive gas dynamics with Professor D. Crighton FRS of Cambridge University in the United Kingdom. Professor Walker and his students carried out joint work with Professor F.T. Smith, of University College London, on various problems in unsteady flow and turbulent boundary layers.

  13. Laser induced uranium fluorescence as an analytical method

    International Nuclear Information System (INIS)

    Krutman, I.

    1985-01-01

    A laser induced fluorescence system was developed to measure uranium trace level amounts in aqueous solution with reliable and simple materials and electronics. A nitrogen pulsed laser was built with the storage energy capacitor directly coupled to laser tube electrodes as a transmission line device. This laser operated at 3Hz repetition rate with peak intensity around 21 Kw and temporal width of 4.5 x 10 -9 s. A sample compartment made of rigid PVC and a photomultiplier housing of aluminium were constructed and assembled forming a single integrated device. As a result of this prototype system we made several analytical measurements with U dissolved in nitric acid to obtain a calibration curve. We obtained a straight line from a plot of U concentration versus fluorescence intensity fitted by a least square method that produced a regression coefficient of 0.994. The lower limit of U determination was 30 ppb -+ 3.5%. (Author) [pt

  14. Analytical methods and problems for the diamides type of extractants

    International Nuclear Information System (INIS)

    Cuillerdier, C.; Nigond, L.; Musikas, C.; Vitart, H.; Hoel, P.

    1989-01-01

    Diamides of carboxylic acids and especially malonamides are able to extract alpha emitters (including trivalent ions such as Am and Cm) contained in the wastes solutions of the nuclear industry. As they are completely incinerable and easy to purify, they could be an alternative to the mixture CMPO-TBP which is used in the TRUEX process. A large oxyalkyl radical enhances the distribution coefficients of americium in nitric acid sufficiently to permit the decontamination of wastes solutions in a classical mixers-settlers battery. Now researches are pursued with the aim of optimizing the formula of extractant, the influence of the structure of the extractant on its basicity and stability under radiolysis and hydrolysis is investigated. Analytical methods (potentiometry and NMR of C 13 ) have been developed for solvent titration and to evaluate the percentage of degradation and to identify some of the degradation products

  15. Nuclear analytical methods for trace element studies in calcified tissues

    International Nuclear Information System (INIS)

    Chaudhry, M.A.; Chaudhry, M.N.

    2001-01-01

    Full text: Various nuclear analytical methods have been developed and applied to determine the elemental composition of calcified tissues (teeth and bones). Fluorine was determined by prompt gamma activation analysis through the 19 F(p,ag) 16 O reaction. Carbon was measured by activation analysis with He-3 ions, and the technique of Proton-Induced X-ray Emission (PIXE) was applied to simultaneously determine Ca, P, and trace elements in well-documented teeth. Dental hard tissues, enamel, dentine, cement, and their junctions, as well as different parts of the same tissue, were examined separately. Furthermore, using a Proton Microprobe, we measured the surface distribution of F and other elements on and around carious lesions on the enamel. The depth profiles of F, and other elements, were also measured right up to the amelodentin junction

  16. Application of analytical methods in authentication and adulteration of honey.

    Science.gov (United States)

    Siddiqui, Amna Jabbar; Musharraf, Syed Ghulam; Choudhary, M Iqbal; Rahman, Atta-Ur-

    2017-02-15

    Honey is synthesized from flower nectar and it is famous for its tremendous therapeutic potential since ancient times. Many factors influence the basic properties of honey including the nectar-providing plant species, bee species, geographic area, and harvesting conditions. Quality and composition of honey is also affected by many other factors, such as overfeeding of bees with sucrose, harvesting prior to maturity, and adulteration with sugar syrups. Due to the complex nature of honey, it is often challenging to authenticate the purity and quality by using common methods such as physicochemical parameters and more specialized procedures need to be developed. This article reviews the literature (between 2000 and 2016) on the use of analytical techniques, mainly NMR spectroscopy, for authentication of honey, its botanical and geographical origin, and adulteration by sugar syrups. NMR is a powerful technique and can be used as a fingerprinting technique to compare various samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Analytical methods used in plutonium purification cycles by trilaurylamine

    International Nuclear Information System (INIS)

    Perez, J.J.

    1965-01-01

    The utilisation of trilaurylamine as a solvent extractant for the purification of plutonium has entailed to perfect a set of analytical methods which involves, various techniques. The organic impurities of the solvent can be titrated by gas-liquid chromatography. The titration of the main degradation product, the di-laurylamine, can be accomplished also by spectro-colorimetry. Potentiometry is used for the analysis of the different salts of amine-nitrate-sulfate-bisulfate as also the extracted nitric acid. The determination of the nitrate in aqueous phase is carried out by constant current potentiometry. The range of application, the accuracy and the procedure of these analysis are related in the present report. (author) [fr

  18. Precision profiles and analytic reliability of radioimmunologic methods

    International Nuclear Information System (INIS)

    Yaneva, Z.; Popova, Yu.

    1991-01-01

    The aim of the present study is to investigate and compare some methods for creation of 'precision profiles' (PP) and to clarify their possibilities for determining the analytical reliability of RIA. Only methods without complicated mathematical calculations has been used. The reproducibility in serums with a concentration of the determinable hormone in the whole range of the calibration curve has been studied. The radioimmunoassay has been performed with TSH-RIA set (ex East Germany), and comparative evaluations - with commercial sets of HOECHST (Germany) and AMERSHAM (GB). Three methods for obtaining the relationship concentration (IU/l) -reproducibility (C.V.,%) are used and a comparison is made of their corresponding profiles: preliminary rough profile, Rodbard-PP and Ekins-PP. It is concluded that the creation of a precision profile is obligatory and the method of its construction does not influence the relationship's course. PP allows to determine concentration range giving stable results which improves the efficiency of the analitical work. 16 refs., 4 figs

  19. A Comparison of Two Approaches for the Ruggedness Testing of an Analytical Method

    International Nuclear Information System (INIS)

    Maestroni, Britt

    2016-01-01

    As part of an initiative under the “Red Analitica de Latino America y el Caribe” (RALACA) network the FAO/IAEA Food and Environmental Protection Laboratory validated a multi-residue method for pesticides in potato. One of the parameters to be assessed was the intra laboratory robustness or ruggedness. The objective of this work was to implement a worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method. As a conclusion to this study, it is evident that there is a need for harmonization of the definition of the terms robustness/ruggedness, the limits, the methodology and the statistical treatment of the generated data. A worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method will soon be posted on the RALACA website (www.red-ralaca.net). This study was carried out with collaborators from LVA (Austria), University of Antwerp (Belgium), University of Leuwen (The Netherlands), Universidad de la Republica (Uruguay) and Agilent technologies.

  20. Groundwater Seepage Estimation into Amirkabir Tunnel Using Analytical Methods and DEM and SGR Method

    OpenAIRE

    Hadi Farhadian; Homayoon Katibeh

    2015-01-01

    In this paper, groundwater seepage into Amirkabir tunnel has been estimated using analytical and numerical methods for 14 different sections of the tunnel. Site Groundwater Rating (SGR) method also has been performed for qualitative and quantitative classification of the tunnel sections. The obtained results of above mentioned methods were compared together. The study shows reasonable accordance with results of the all methods unless for two sections of tunnel. In these t...

  1. Analytical resource assessment method for continuous (unconventional) oil and gas accumulations - The "ACCESS" Method

    Science.gov (United States)

    Crovelli, Robert A.; revised by Charpentier, Ronald R.

    2012-01-01

    The U.S. Geological Survey (USGS) periodically assesses petroleum resources of areas within the United States and the world. The purpose of this report is to explain the development of an analytic probabilistic method and spreadsheet software system called Analytic Cell-Based Continuous Energy Spreadsheet System (ACCESS). The ACCESS method is based upon mathematical equations derived from probability theory. The ACCESS spreadsheet can be used to calculate estimates of the undeveloped oil, gas, and NGL (natural gas liquids) resources in a continuous-type assessment unit. An assessment unit is a mappable volume of rock in a total petroleum system. In this report, the geologic assessment model is defined first, the analytic probabilistic method is described second, and the spreadsheet ACCESS is described third. In this revised version of Open-File Report 00-044 , the text has been updated to reflect modifications that were made to the ACCESS program. Two versions of the program are added as appendixes.

  2. Multiclass methods for the analysis of antibiotic residues in milk by liquid chromatography coupled to mass spectrometry: A review.

    Science.gov (United States)

    Rossi, Rosanna; Saluti, Giorgio; Moretti, Simone; Diamanti, Irene; Giusepponi, Danilo; Galarini, Roberta

    2018-02-01

    Milk is an important and beneficial food from a nutritional point of view, being an indispensable source of high quality proteins. Furthermore, it is a raw material for many dairy products, such as yoghurt, cheese, cream etc. Before reaching consumers, milk goes through production, processing and circulation. Each step involves potentially unsafe factors, such as chemical contamination that can affect milk quality. Antibiotics are widely used in veterinary medicine for dry cow therapy and mastitis treatment in lactating cows, which can cause the presence of antimicrobial residues in milk. In order to ensure consumers' safety, milk is analyzed to make sure that the fixed Maximum Residue Limits (MRLs) for antibiotics are not exceeded. Multiclass methods can monitor more drug classes through a single analysis, so they are faster, less time-consuming and cheaper than traditional methods (single-class); this aspect is particularly important for milk, which is a highly perishable food. Nevertheless, multiclass methods for veterinary drug residues in foodstuffs are real analytical challenges. This article reviews the major multiclass methods published for the determination of antibiotic residues in milk by liquid chromatography coupled to mass spectrometry, with a special focus on sample preparation approaches.

  3. An analytical method for predicting postwildfire peak discharges

    Science.gov (United States)

    Moody, John A.

    2012-01-01

    An analytical method presented here that predicts postwildfire peak discharge was developed from analysis of paired rainfall and runoff measurements collected from selected burned basins. Data were collected from 19 mountainous basins burned by eight wildfires in different hydroclimatic regimes in the western United States (California, Colorado, Nevada, New Mexico, and South Dakota). Most of the data were collected for the year of the wildfire and for 3 to 4 years after the wildfire. These data provide some estimate of the changes with time of postwildfire peak discharges, which are known to be transient but have received little documentation. The only required inputs for the analytical method are the burned area and a quantitative measure of soil burn severity (change in the normalized burn ratio), which is derived from Landsat reflectance data and is available from either the U.S. Department of Agriculture Forest Service or the U.S. Geological Survey. The method predicts the postwildfire peak discharge per unit burned area for the year of a wildfire, the first year after a wildfire, and the second year after a wildfire. It can be used at three levels of information depending on the data available to the user; each subsequent level requires either more data or more processing of the data. Level 1 requires only the burned area. Level 2 requires the burned area and the basin average value of the change in the normalized burn ratio. Level 3 requires the burned area and the calculation of the hydraulic functional connectivity, which is a variable that incorporates the sequence of soil burn severity along hillslope flow paths within the burned basin. Measurements indicate that the unit peak discharge response increases abruptly when the 30-minute maximum rainfall intensity is greater than about 5 millimeters per hour (0.2 inches per hour). This threshold may relate to a change in runoff generation from saturated-excess to infiltration-excess overland flow. The

  4. Measurement of company effectiveness using analytic network process method

    Science.gov (United States)

    Goran, Janjić; Zorana, Tanasić; Borut, Kosec

    2017-07-01

    The sustainable development of an organisation is monitored through the organisation's performance, which beforehand incorporates all stakeholders' requirements in its strategy. The strategic management concept enables organisations to monitor and evaluate their effectiveness along with efficiency by monitoring of the implementation of set strategic goals. In the process of monitoring and measuring effectiveness, an organisation can use multiple-criteria decision-making methods as help. This study uses the method of analytic network process (ANP) to define the weight factors of the mutual influences of all the important elements of an organisation's strategy. The calculation of an organisation's effectiveness is based on the weight factors and the degree of fulfilment of the goal values of the strategic map measures. New business conditions influence the changes in the importance of certain elements of an organisation's business in relation to competitive advantage on the market, and on the market, increasing emphasis is given to non-material resources in the process of selection of the organisation's most important measures.

  5. Measurement of company effectiveness using analytic network process method

    Directory of Open Access Journals (Sweden)

    Goran Janjić

    2017-07-01

    Full Text Available The sustainable development of an organisation is monitored through the organisation’s performance, which beforehand incorporates all stakeholders’ requirements in its strategy. The strategic management concept enables organisations to monitor and evaluate their effectiveness along with efficiency by monitoring of the implementation of set strategic goals. In the process of monitoring and measuring effectiveness, an organisation can use multiple-criteria decision-making methods as help. This study uses the method of analytic network process (ANP to define the weight factors of the mutual influences of all the important elements of an organisation’s strategy. The calculation of an organisation’s effectiveness is based on the weight factors and the degree of fulfilment of the goal values of the strategic map measures. New business conditions influence the changes in the importance of certain elements of an organisation’s business in relation to competitive advantage on the market, and on the market, increasing emphasis is given to non-material resources in the process of selection of the organisation’s most important measures.

  6. Analytic-numerical method of determining the freezing front location

    Directory of Open Access Journals (Sweden)

    R. Grzymkowski

    2011-07-01

    Full Text Available Mathematical modeling of thermal processes combined with the reversible phase transitions of type: solid phase – liquid phase leads to formulation of the parabolic boundary problems with the moving boundary. Solution of such defined problem requires, most often, to use sophisticated numerical techniques and far advanced mathematical tools. Excellent illustration of the complexity of considered problems, as well as of the variety of approaches used for finding their solutions, gives the papers [1-4]. In the current paper, the authors present the, especially attractive from the engineer point of view, analytic-numerical method for finding the approximate solution of selected class of problems which can be reduced to the one-phase solidification problem of a plate with the unknown a priori, varying in time boundary of the region in which the solution is sought. Proposed method is based on the known formalism of initial expansion of the sought function describing the temperature field into the power series, some coefficients of which are determined with the aid of boundary conditions, and on the approximation of the function defining the location of freezing front with the broken line, parameters of which are numerically determined.

  7. Quality control and analytical methods for baculovirus-based products.

    Science.gov (United States)

    Roldão, António; Vicente, Tiago; Peixoto, Cristina; Carrondo, Manuel J T; Alves, Paula M

    2011-07-01

    Recombinant baculoviruses (rBac) are used for many different applications, ranging from bio-insecticides to the production of heterologous proteins, high-throughput screening of gene functions, drug delivery, in vitro assembly studies, design of antiviral drugs, bio-weapons, building blocks for electronics, biosensors and chemistry, and recently as a delivery system in gene therapy. Independent of the application, the quality, quantity and purity of rBac-based products are pre-requisites demanded by regulatory authorities for product licensing. To guarantee maximization utility, it is necessary to delineate optimized production schemes either using trial-and-error experimental setups ("brute force" approach) or rational design of experiments by aid of in silico mathematical models (Systems Biology approach). For that, one must define all of the main steps in the overall process, identify the main bioengineering issues affecting each individual step and implement, if required, accurate analytical methods for product characterization. In this review, current challenges for quality control (QC) technologies for up- and down-stream processing of rBac-based products are addressed. In addition, a collection of QC methods for monitoring/control of the production of rBac derived products are presented as well as innovative technologies for faster process optimization and more detailed product characterization. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Modern analytic methods applied to the art and archaeology

    International Nuclear Information System (INIS)

    Tenorio C, M. D.; Longoria G, L. C.

    2010-01-01

    The interaction of diverse areas as the analytic chemistry, the history of the art and the archaeology has allowed the development of a variety of techniques used in archaeology, in conservation and restoration. These methods have been used to date objects, to determine the origin of the old materials and to reconstruct their use and to identify the degradation processes that affect the integrity of the art works. The objective of this chapter is to offer a general vision on the researches that have been realized in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of cultural goods. A series of researches carried out in collaboration with national investigators and of the foreigner is described shortly, as well as with the great support of degree students and master in archaeology of the National School of Anthropology and History, since one of the goals that have is to diffuse the knowledge of the existence of these techniques among the young archaeologists, so that they have a wider vision of what they could use in an in mediate future and they can check hypothesis with scientific methods. (Author)

  9. Development of analytical methods for iodine speciation in fresh water

    International Nuclear Information System (INIS)

    Takaku, Yuichi; Ohtsuka, Yoshihito; Hisamatsu, Shun'ichi

    2007-01-01

    Analytical methods for physicochemical speciation of iodine in fresh water samples were developed to elucidate its behavior in the environment. The methods combined inductively coupled plasma mass spectrometry (ICP-MS) with size exclusion high performance liquid chromatography (SEC) or capillary electrophoresis (CE). Freshwater samples were collected from Lake Towada and rivers surrounding the lake. After filtration through a 0.45 μm pore size membrane filter, iodine in the water samples was pre-concentrated with an ultra-filtration filter which had a cut-off size of 10 kDa. The fraction with molecular size over 10 kDa was concentrated to 100 times in the original water, and then introduced into the SEC-ICP-MS. Molecular size chromatograms of all river and lake water samples showed two peaks for iodine concentrations: 40 kDa and 20 kDa. The method for separately determining two valence states of inorganic iodine, I - and IO 3 - , was also developed using the CE-ICP-MS system and it was successfully applied to the fresh water samples. Analysis results of surface water samples in Lake Towada and rivers surrounding the lake indicated that the chemical form of inorganic iodine in all samples was IO 3 - . Additional lake water samples were collected from Lake O-ike-higashi in the Juni-ko area at Shirakami-Sanchi, which is a UNESCO natural world heritage. The lake has a strong thermocline during all seasons; its bottom layer is in a highly reductive state. Depth profiles of I - and IO 3 - clearly showed that I - was not detected in the surface layer, but it was predominant in the bottom layer, and vice versa for IO 3 - . As this separation method is rapid and sensitive, it will be widely used in the future. (author)

  10. Propulsion and launching analysis of variable-mass rockets by analytical methods

    OpenAIRE

    D.D. Ganji; M. Gorji; M. Hatami; A. Hasanpour; N. Khademzadeh

    2013-01-01

    In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM), homotopy perturbation method (HPM) and least square method (LSM) were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a paramet...

  11. Reduction method for residual stress of welded joint using random vibration

    International Nuclear Information System (INIS)

    Aoki, Shigeru; Nishimura, Tadashi; Hiroi, Tetsumaro

    2005-01-01

    Welded joints are used for construction of many structures. Residual stress is induced near the bead caused by locally given heat. Tensile residual stress on the surface may reduce fatigue strength. In this paper, a new method for reduction of residual stress using vibration during welding is proposed. As vibrational load, random vibration, white noise and filtered white noise are used. Two thin plates are butt-welded. Residual stress is measured with a paralleled beam X-ray diffractometer with scintillation counter after removing quenched scale chemically. It is concluded that tensile residual stress near the bead is reduced by using random vibration during welding

  12. Analytical one parameter method for PID motion controller settings

    NARCIS (Netherlands)

    van Dijk, Johannes; Aarts, Ronald G.K.M.

    2012-01-01

    In this paper analytical expressions for PID-controllers settings for electromechanical motion systems are presented. It will be shown that by an adequate frequency domain oriented parametrization, the parameters of a PID-controller are analytically dependent on one variable only, the cross-over

  13. A new spectrophotometric method for determination of residual ...

    African Journals Online (AJOL)

    Polydiallyldimethylammonium chloride (polyDADMAC) is a water-soluble cationic polyelectrolyte used for water treatment. Its residues in treated water are contaminants as they react with chlorine to produce a carcinogenic compound. Commonly-used techniques for quantification of the polycation, such as colloidal and ...

  14. Several methods applied to measuring residual stress in a known specimen

    International Nuclear Information System (INIS)

    Prime, M.B.; Rangaswamy, P.; Daymond, M.R.; Abelin, T.G.

    1998-01-01

    In this study, a beam with a precisely known residual stress distribution provided a unique experimental opportunity. A plastically bent beam was carefully prepared in order to provide a specimen with a known residual stress profile. 21Cr-6Ni-9Mn austenitic stainless steel was obtained as 43 mm square forged stock. Several methods were used to determine the residual stresses, and the results were compared to the known values. Some subtleties of applying the various methods were exposed

  15. Multi-residue method for the determination of antibiotics and some of their metabolites in seafood.

    Science.gov (United States)

    Serra-Compte, Albert; Álvarez-Muñoz, Diana; Rodríguez-Mozaz, Sara; Barceló, Damià

    2017-06-01

    The presence of antibiotics in seafood for human consumption may pose a risk for consumers. A methodology for the analysis of antibiotics in seafood based on QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction, followed by detection and quantification using liquid chromatography coupled to mass spectrometry was developed. The analytical method was evaluated for the determination of 23 antibiotics (including parent compounds and some metabolites) in fish, mussels and clams. Recoveries ranged between 30% and 70% for most of the compounds and method detection and quantification limits (MDLs and MQLs) were between 0.01 and 0.31 ng/g dry weigh (dw) and 0.02-1.03 ng/g (dw) respectively. Real seafood samples were analysed using this method. Nine antibiotics were found at levels above MDLs; however none of them exceed the maximum residue limits (MRL) established by the authorities. Tetracycline was the most ubiquitous compound, presenting also the highest concentration: 5.63 ng/g (dw) in fish from Netherlands. In addition, an alternative technique based on microbial growth inhibition was explored as semiquantitative detection method of antibiotics in seafood. This methodology could be applied as a fast screening technique for the detection of macrolides and β-lactams in seafood but further research is needed for other antibiotics families. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Oxcarbazepine: validation and application of an analytical method

    Directory of Open Access Journals (Sweden)

    Paula Cristina Rezende Enéas

    2010-06-01

    Full Text Available Oxcarbazepine (OXC is an important anticonvulsant and mood stabilizing drug. A pharmacopoeial monograph for OXC is not yet available and therefore the development and validation of a new analytical method for quantification of this drug is essential. In the present study, a UV spectrophotometric method for the determination of OXC was developed. The various parameters, such as linearity, precision, accuracy and specificity, were studied according to International Conference on Harmonization Guidelines. Batches of 150 mg OXC capsules were prepared and analyzed using the validated UV method. The formulations were also evaluated for parameters including drug-excipient compatibility, flowability, uniformity of weight, disintegration time, assay, uniformity of content and the amount of drug dissolved during the first hour.Oxcarbazepina (OXC é um fármaco anticonvulsivante e estabilizante do humor. O desenvolvimento e validação de método analítico para quantificação da OXC são de fundamental importância devido à ausência de monografias farmacopéicas oficiais para esse fármaco. Nesse trabalho, um método espectrofotométrico UV para determinação da OXC foi desenvolvido. O método proposto foi validado seguindo os parâmetros de linearidade, precisão, exatidão e especificidade de acordo com as normas da Conferência Internacional de Harmonização. Cápsulas de OXC 150 mg foram preparadas e analisadas utilizando-se o método analítico validado. As formulações foram avaliadas com relação à compatibilidade fármaco-excipientes, fluidez, determinação de peso, tempo de desintegração, doseamento, uniformidade de conteúdo e quantidade do fármaco dissolvido após 60 minutos.

  17. Measurement of residual stress in textured Al alloy by neutron diffraction method

    International Nuclear Information System (INIS)

    Okido, S.; Hayashi, M.; Tanaka, K.; Akiniwa, Y.; Minakawa, N.; Morii, Y.

    1999-01-01

    Residual stress generated in a shrunken aluminum alloy specimen, which was prepared for the round robin test conducted by VAMAS (Versailles Project on Advanced Materials and Standards) TWA-20 organized for the purpose of standardizing residual stress measurement methods, was evaluated by a neutron diffraction method. The main purpose of the round robin test was to assess the reproducibility of data obtained with the measurement facilities of the participants. The general standard of the Residual Stress Analyzer (RESA) constructed in the Japan Atomic Energy Research Institute was verified from the measured residual strains, which were equivalent to the values calculated by FEM and values measured by the research facilities in North America. Residual stress was calculated from residual strain in three perpendicular directions. The diffraction intensities were dependent on measurement directions since the prepared specimen possessed texture. Diffraction profiles in directions having a weak diffraction intensity caused an inaccurate evaluation of the residual stress. To solve this problem, a new method for evaluating residual stress with respect to diffraction plane dependency of the elastic constant was applied. The diffraction plane giving the highest intensity among 110, 200, and 220 diffraction was used to evaluate the residual strain in each of three directions. The residual strain obtained on the used diffraction plane was converted to the equivalent strain for the defined diffraction plane using the ratio of elastic constants of these two planes. The developed evaluation method achieved highly accurate measurement and remarkable efficiency in the measurement process. (author)

  18. Sulfathiazole: analytical methods for quantification in seawater and macroalgae.

    Science.gov (United States)

    Leston, Sara; Nebot, Carolina; Nunes, Margarida; Cepeda, Alberto; Pardal, Miguel Ângelo; Ramos, Fernando

    2015-01-01

    The awareness of the interconnection between pharmaceutical residues, human health, and aquaculture has highlighted the concern with the potential harmful effects it can induce. Furthermore, to better understand the consequences more research is needed and to achieve that new methodologies on the detection and quantification of pharmaceuticals are necessary. Antibiotics are a major class of drugs included in the designation of emerging contaminants, representing a high risk to natural ecosystems. Among the most prescribed are sulfonamides, with sulfathiazole being the selected compound to be investigated in this study. In the environment, macroalgae are an important group of producers, continuously exposed to contaminants, with a significant role in the trophic web. Due to these characteristics are already under scope for the possibility of being used as bioindicators. The present study describes two new methodologies based on liquid chromatography for the determination of sulfathiazole in seawater and in the green macroalgae Ulva lactuca. Results show both methods were validated according to international standards, with MS/MS detection showing more sensitivity as expected with LODs of 2.79ng/g and 1.40ng/mL for algae and seawater, respectively. As for UV detection the values presented were respectively 2.83μg/g and 2.88μg/mL, making it more suitable for samples originated in more contaminated sites. The methods were also applied to experimental data with success with results showing macroalgae have potential use as indicators of contamination. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. AN ANALYTICAL METHOD FOR CHEMICAL SPECIATION OF SELENIUM IN SOIL

    Directory of Open Access Journals (Sweden)

    Constantin Luca

    2010-10-01

    Full Text Available Selenium is an essential microelement, sometimes redoubtable, through its beneficial role - risk depending on its concentration in the food chain, at low dose is an important nutrient in the life of humans and animals, contrary at high doses, it becomes toxic. Selenium may be find itself in the environment (soil, sediment, water in many forms (oxidized, reduced, organometallic which determine their mobility and toxicity. Determination of chemical speciation (identification of different chemical forms provides much more complete information for a better understanding of the behavior and the potential impact on the environment. In this work we present the results of methodological research on the extraction of sequential forms of selenium in the soil and the coupling of analytical methods capable of identifying very small amounts of selenium in soils An efficient scheme of sequential extractions forms of selenium (SES consisting in atomic absorption spectrometry coupled with hydride generation (HGAAS has been developed into five experimental steps, detailed in the paper. This operational scheme has been applied to the analysis of chemical speciation in the following areas: the Bărăgan Plain and Central Dobrogea of Romania.

  20. Analytical method to estimate resin cement diffusion into dentin

    Science.gov (United States)

    de Oliveira Ferraz, Larissa Cristina; Ubaldini, Adriana Lemos Mori; de Oliveira, Bruna Medeiros Bertol; Neto, Antonio Medina; Sato, Fracielle; Baesso, Mauro Luciano; Pascotto, Renata Corrêa

    2016-05-01

    This study analyzed the diffusion of two resin luting agents (resin cements) into dentin, with the aim of presenting an analytical method for estimating the thickness of the diffusion zone. Class V cavities were prepared in the buccal and lingual surfaces of molars (n=9). Indirect composite inlays were luted into the cavities with either a self-adhesive or a self-etch resin cement. The teeth were sectioned bucco-lingually and the cement-dentin interface was analyzed by using micro-Raman spectroscopy (MRS) and scanning electron microscopy. Evolution of peak intensities of the Raman bands, collected from the functional groups corresponding to the resin monomer (C-O-C, 1113 cm-1) present in the cements, and the mineral content (P-O, 961 cm-1) in dentin were sigmoid shaped functions. A Boltzmann function (BF) was then fitted to the peaks encountered at 1113 cm-1 to estimate the resin cement diffusion into dentin. The BF identified a resin cement-dentin diffusion zone of 1.8±0.4 μm for the self-adhesive cement and 2.5±0.3 μm for the self-etch cement. This analysis allowed the authors to estimate the diffusion of the resin cements into the dentin. Fitting the MRS data to the BF contributed to and is relevant for future studies of the adhesive interface.

  1. NIOSH Manual of Analytical Methods (third edition). Fourth supplement

    Energy Technology Data Exchange (ETDEWEB)

    1990-08-15

    The NIOSH Manual of Analytical Methods, 3rd edition, was updated for the following chemicals: allyl-glycidyl-ether, 2-aminopyridine, aspartame, bromine, chlorine, n-butylamine, n-butyl-glycidyl-ether, carbon-dioxide, carbon-monoxide, chlorinated-camphene, chloroacetaldehyde, p-chlorophenol, crotonaldehyde, 1,1-dimethylhydrazine, dinitro-o-cresol, ethyl-acetate, ethyl-formate, ethylenimine, sodium-fluoride, hydrogen-fluoride, cryolite, sodium-hexafluoroaluminate, formic-acid, hexachlorobutadiene, hydrogen-cyanide, hydrogen-sulfide, isopropyl-acetate, isopropyl-ether, isopropyl-glycidyl-ether, lead, lead-oxide, maleic-anhydride, methyl-acetate, methyl-acrylate, methyl-tert-butyl ether, methyl-cellosolve-acetate, methylcyclohexanol, 4,4'-methylenedianiline, monomethylaniline, monomethylhydrazine, nitric-oxide, p-nitroaniline, phenyl-ether, phenyl-ether-biphenyl mixture, phenyl-glycidyl-ether, phenylhydrazine, phosphine, ronnel, sulfuryl-fluoride, talc, tributyl-phosphate, 1,1,2-trichloro-1,2,2-trifluoroethane, trimellitic-anhydride, triorthocresyl-phosphate, triphenyl-phosphate, and vinyl-acetate.

  2. Analytical methods for waste minimisation in the convenience food industry.

    Science.gov (United States)

    Darlington, R; Staikos, T; Rahimifard, S

    2009-04-01

    Waste creation in some sectors of the food industry is substantial, and while much of the used material is non-hazardous and biodegradable, it is often poorly dealt with and simply sent to landfill mixed with other types of waste. In this context, overproduction wastes were found in a number of cases to account for 20-40% of the material wastes generated by convenience food manufacturers (such as ready-meals and sandwiches), often simply just to meet the challenging demands placed on the manufacturer due to the short order reaction time provided by the supermarkets. Identifying specific classes of waste helps to minimise their creation, through consideration of what the materials constitute and why they were generated. This paper aims to provide means by which food industry wastes can be identified, and demonstrate these mechanisms through a practical example. The research reported in this paper investigated the various categories of waste and generated three analytical methods for the support of waste minimisation activities by food manufacturers. The waste classifications and analyses are intended to complement existing waste minimisation approaches and are described through consideration of a case study convenience food manufacturer that realised significant financial savings through waste measurement, analysis and reduction.

  3. [Method of detection of residual tissues in recurrent operations on the thyroid gland].

    Science.gov (United States)

    Gostimskiĭ, A V; Romanchishen, A F; Zaĭtseva, I V; Kuznetsova, Iu V

    2014-01-01

    A search of residual tissues is complicated in recurrent operations on the thyroid gland. The Saint-Petersburg Centre of Surgery of the Endocrine System and Oncology developed the method of detection of residual tissues of the thyroid gland with the aim of preoperative chromothyroidolymphography under control of ultrasound. The method consisted of US performance during 15-20 minutes before the operation and an introduction of 1% sterile water solution of methylene blue in revealed residual tissues of the thyroid gland. The volume of injected coloring agent was 0.5-2 ml in the residual tissue volume smaller than 9 cm3 and 2-3 ml injected in case of more than 9 cm3. The residual tissues of the thyroid gland accurately visualized during the following operation. Described method gives the possibility to detect all regions of residual tissues which should be removed and at the same time it shortens a revision and surgery trauma.

  4. The challenge of packaging and transporting mixed waste samples and residues arising from the Department of Energy's Analytical Services Program

    International Nuclear Information System (INIS)

    Pope, R.B.; Blalock, L.G.; Conroy, M.J.

    1993-01-01

    This paper discusses the background and magnitude of challenges that the US Department of Energy (DOE) faces in accomplishing its task to characterize and remediate wastes at its sites. The analytical-sample-shipment needs are discussed, anticipated packaging and transport problems are assessed, and the way in which DOE's Transportation Management Division is preparing to support other DOE organizations in addressing these challenges is summarized. Many challenges arising from the need to ship analytical samples are centered upon resolving packaging issues. Resolution of these challenges will require further efforts to define and quantify packaging requirements better and to develop methods for addressing resultant issues in a timely, an efficient, and a safe manner

  5. CSmetaPred: a consensus method for prediction of catalytic residues.

    Science.gov (United States)

    Choudhary, Preeti; Kumar, Shailesh; Bachhawat, Anand Kumar; Pandit, Shashi Bhushan

    2017-12-22

    Knowledge of catalytic residues can play an essential role in elucidating mechanistic details of an enzyme. However, experimental identification of catalytic residues is a tedious and time-consuming task, which can be expedited by computational predictions. Despite significant development in active-site prediction methods, one of the remaining issues is ranked positions of putative catalytic residues among all ranked residues. In order to improve ranking of catalytic residues and their prediction accuracy, we have developed a meta-approach based method CSmetaPred. In this approach, residues are ranked based on the mean of normalized residue scores derived from four well-known catalytic residue predictors. The mean residue score of CSmetaPred is combined with predicted pocket information to improve prediction performance in meta-predictor, CSmetaPred_poc. Both meta-predictors are evaluated on two comprehensive benchmark datasets and three legacy datasets using Receiver Operating Characteristic (ROC) and Precision Recall (PR) curves. The visual and quantitative analysis of ROC and PR curves shows that meta-predictors outperform their constituent methods and CSmetaPred_poc is the best of evaluated methods. For instance, on CSAMAC dataset CSmetaPred_poc (CSmetaPred) achieves highest Mean Average Specificity (MAS), a scalar measure for ROC curve, of 0.97 (0.96). Importantly, median predicted rank of catalytic residues is the lowest (best) for CSmetaPred_poc. Considering residues ranked ≤20 classified as true positive in binary classification, CSmetaPred_poc achieves prediction accuracy of 0.94 on CSAMAC dataset. Moreover, on the same dataset CSmetaPred_poc predicts all catalytic residues within top 20 ranks for ~73% of enzymes. Furthermore, benchmarking of prediction on comparative modelled structures showed that models result in better prediction than only sequence based predictions. These analyses suggest that CSmetaPred_poc is able to rank putative catalytic

  6. Analytical method of waste allocation in waste management systems: Concept, method and case study

    International Nuclear Information System (INIS)

    Bergeron, Francis C.

    2017-01-01

    Waste is not a rejected item to dispose anymore but increasingly a secondary resource to exploit, influencing waste allocation among treatment operations in a waste management (WM) system. The aim of this methodological paper is to present a new method for the assessment of the WM system, the “analytical method of the waste allocation process” (AMWAP), based on the concept of the “waste allocation process” defined as the aggregation of all processes of apportioning waste among alternative waste treatment operations inside or outside the spatial borders of a WM system. AMWAP contains a conceptual framework and an analytical approach. The conceptual framework includes, firstly, a descriptive model that focuses on the description and classification of the WM system. It includes, secondly, an explanatory model that serves to explain and to predict the operation of the WM system. The analytical approach consists of a step-by-step analysis for the empirical implementation of the conceptual framework. With its multiple purposes, AMWAP provides an innovative and objective modular method to analyse a WM system which may be integrated in the framework of impact assessment methods and environmental systems analysis tools. Its originality comes from the interdisciplinary analysis of the WAP and to develop the conceptual framework. AMWAP is applied in the framework of an illustrative case study on the household WM system of Geneva (Switzerland). It demonstrates that this method provides an in-depth and contextual knowledge of WM. - Highlights: • The study presents a new analytical method based on the waste allocation process. • The method provides an in-depth and contextual knowledge of the waste management system. • The paper provides a reproducible procedure for professionals, experts and academics. • It may be integrated into impact assessment or environmental system analysis tools. • An illustrative case study is provided based on household waste

  7. Analytic Method to Estimate Particle Acceleration in Flux Ropes

    Science.gov (United States)

    Guidoni, S. E.; Karpen, J. T.; DeVore, C. R.

    2015-01-01

    The mechanism that accelerates particles to the energies required to produce the observed high-energy emission in solar flares is not well understood. Drake et al. (2006) proposed a kinetic mechanism for accelerating electrons in contracting magnetic islands formed by reconnection. In this model, particles that gyrate around magnetic field lines transit from island to island, increasing their energy by Fermi acceleration in those islands that are contracting. Based on these ideas, we present an analytic model to estimate the energy gain of particles orbiting around field lines inside a flux rope (2.5D magnetic island). We calculate the change in the velocity of the particles as the flux rope evolves in time. The method assumes a simple profile for the magnetic field of the evolving island; it can be applied to any case where flux ropes are formed. In our case, the flux-rope evolution is obtained from our recent high-resolution, compressible 2.5D MHD simulations of breakout eruptive flares. The simulations allow us to resolve in detail the generation and evolution of large-scale flux ropes as a result of sporadic and patchy reconnection in the flare current sheet. Our results show that the initial energy of particles can be increased by 2-5 times in a typical contracting island, before the island reconnects with the underlying arcade. Therefore, particles need to transit only from 3-7 islands to increase their energies by two orders of magnitude. These macroscopic regions, filled with a large number of particles, may explain the large observed rates of energetic electron production in flares. We conclude that this mechanism is a promising candidate for electron acceleration in flares, but further research is needed to extend our results to 3D flare conditions.

  8. Study of TATP: method for determination of residual acids in TATP.

    Science.gov (United States)

    Matyáš, Robert; Chýlková, Jaromíra

    2013-05-10

    Triacetone triperoxide (3,3,6,6,9,9-hexamethyl-1,2,4,5,7,8-hexoxonane, TATP) is nowadays one of the most commonly used improvised explosives. It is prepared by the action of hydrogen peroxide on acetone in an acidic environment. Easily available mineral acids - hydrochloric, sulfuric, nitric and perchloric - are the most often recommended on the extremist web pages dealing with improvised production of explosives. The various TATP producers' choice of acid mainly depends on the author's experiences and the local availability of the acid. A knowledge of the kind of acid used for TATP production can help in detecting the person who has made the TATP, or who has committed a criminal act using TATP. Therefore, a capillary isotachophoretic method was developed for determination of residual anions (originating from the acid used during TATP synthesis) in the resulting TATP crystals. This analytical method has proved to be reliable; the acid used for TATP synthesis was correctly identified in all samples analyzed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. A direct recursive residue generation method: application to photoionization of hydrogen in static electric fields

    International Nuclear Information System (INIS)

    Karlsson, H.O.; Goscinski, O.

    1994-01-01

    In studies of hydrogenic systems via the recursive residue generation method (RRGM) the major bottleneck is the matrix vector product HC, between the Hamiltonian matrix H and a Lanczos vector C. For highly excited states and/or strong perturbations the size of H grows fast leading to storage problems. By making use of direct methods, i.e. avoidance of explicit construction of large Hamiltonian matrices, such problems can be overcome. Utilizing the underlying analytical properties of the Laguerre basis e -λr L k 2l+2 (2λr) a direct RRGM (D-RRGM) for the unperturbed hydrogenic Hamiltonian is derived, changing the storage needs from scaling as N 2 to 4N where N is the number of radial functions for each factorized H o (l,m) block with the possibility of parallel processing. A further computational simplification is introduced by putting the expression for the photoionization (PI) cross section in the rational form conventionally used in the representation of density of states (DOS). This allows the construction of the PI cross section directly from the tridiagonal Lanczos matrix avoiding the explicit calculation of individual eigen values and eigenvectors. (Author)

  10. A simple analytic method for estimating T2 in the knee from DESS.

    Science.gov (United States)

    Sveinsson, B; Chaudhari, A S; Gold, G E; Hargreaves, B A

    2017-05-01

    To introduce a simple analytical formula for estimating T 2 from a single Double-Echo in Steady-State (DESS) scan. Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T 2 estimation from one DESS scan. Simulations were performed to demonstrate cancellation of different echo pathways to validate this simple model. The resulting analytic formula was compared to previous methods for T 2 estimation using DESS and fast spin-echo scans in agar phantoms and knee cartilage in three volunteers and three patients. The DESS approach allows 3D (256×256×44) T 2 -mapping with fat suppression in scan times of 3-4min. The simulations demonstrated that the model approximates the true signal very well. If the T 1 is within 20% of the assumed T 1 , the T 2 estimation error was shown to be less than 5% for typical scans. The inherent residual error in the model was demonstrated to be small both due to signal decay and opposing signal contributions. The estimated T 2 from the linear relationship agrees well with reference scans, both for the phantoms and in vivo. The method resulted in less underestimation of T 2 than previous single-scan approaches, with processing times 60 times faster than using a numerical fit. A simplified relationship between the two DESS signals allows for rapid 3D T 2 quantification with DESS that is accurate, yet also simple. The simplicity of the method allows for immediate T 2 estimation in cartilage during the MRI examination. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Residual Stress Analysis in Deep Drawn Twinning Induced Plasticity (TWIP) Steels Using Neutron Diffraction Method

    Science.gov (United States)

    Hong, Seokmin; Lee, Junghoon; Lee, Sunghak; Woo, Wanchuck; Kim, Sung-Kyu; Kim, Hyoung Seop

    2014-04-01

    In Twinning Induced Plasticity (TWIP) steels, delayed fracture occurs due to residual stresses induced during deep drawing. In order to investigate the relation between residual stresses and delayed fracture, in the present study, residual stresses of deep drawn TWIP steels (22Mn-0.6C and 18Mn-2Al-0.6C steels) were investigated using the finite element method (FEM) and neutron diffraction measurements. In addition, the delayed fracture properties were examined by dipping tests of cup specimens in the boiled water. In the FEM analysis, the hoop direction residual stress was highly tensile at cup edge, and the delayed fracture was initiated by the separation of hoop direction and propagated in an axial direction. According to the neutron diffraction analysis, residual stresses in 18Mn-2Al-0.6C steel were about half the residual stresses in 22Mn-0.6C steel. From the residual strain measurement using electron back-scatter diffraction, formation of deformation twins caused a lot of grain rotation and local strain at the grain boundaries and twin boundaries. These local residual strains induce residual stress at boundaries. Al addition in TWIP steels restrained the formation of deformation twins and dynamic strain aging, resulting in more homogeneous stress and strain distributions in cup specimens. Thus, in Al-added TWIP steels, residual stress of cup specimen considerably decreased, and delayed fracture resistance was remarkably improved by the addition of Al in TWIP steels.

  12. The release of 14C-chlorsulfuron bound residue by autoclaving method and its identification

    International Nuclear Information System (INIS)

    Guo Jiangfeng; Sun Jinhe; Ye Qingfu

    1999-01-01

    When individual microorganisms were used to release bound pesticide residues, it was usually not take into full account whether the autoclaving method could lead to the release of bound residues. The soil containing bound 14 C-chlorsulfuron residues was treated with an autoclave in this study. The results reveal that the bound 14 C-chlorsulfuron residue can be released from the soil when treated with the autoclave and the release rate can be remarkably enhanced by adding water into the soil when subjected to such treatment. A TLC analysis showed that the released 14 C-residue was one of the degraded products of 14 C-chlorsulfuron. After derivatization and analysis using the GC-MS, the released 14 C-residue was tentatively identified as 2-amino-4-hydroxyl-6-methyl-1,3,5-triazine

  13. Method for Reduction of Pesticide Residue Levels in Raspberry and Blackcurrant Based on Utilization of Ozone

    Directory of Open Access Journals (Sweden)

    Balawejder Maciej

    2014-12-01

    Full Text Available The method for the reduction of pesticide residues in soft fruits based on utilization of ozone was proposed. The procedure allows for effective reduction of boscalid residues by 38% in raspberries, and about 58% thiram in blackcurrants. Furthermore, it can be used on an industrial scale.

  14. Hanford environmental analytical methods: Methods as of March 1990. Volume 3, Appendix A2-I

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    This paper from the analytical laboratories at Hanford describes the method used to measure pH of single-shell tank core samples. Sludge or solid samples are mixed with deionized water. The pH electrode used combines both a sensor and reference electrode in one unit. The meter amplifies the input signal from the electrode and displays the pH visually.

  15. Research on measurement of residual stresses of hemispherical lithium hydride by blind-hole method

    Energy Technology Data Exchange (ETDEWEB)

    Bo, Lin, E-mail: linbo@caep.cn [China Academy of Engineering Physics, P.O. Box: 919-71, Mianyang 621900, Sichuan (China); Kaihui, He [China International Nuclear Fusion Energy Program Execution Center, 15B, Fuxing Rd, 100862 Beijing (China); Dongwei, Shan; Weicai, Yang; Yonggang, Chi; Mei, Liu; Jun, Shen [China Academy of Engineering Physics, P.O. Box: 919-71, Mianyang 621900, Sichuan (China)

    2014-04-15

    Highlights: • The residual stresses of sintered and machined lithium hydride of SR40 hyper-hemispherical and SR30 inner hemispherical sample were measured by blind-hole method. • The nearly 45 degrees direction residual stresses of SR40 hyper-hemisphere and SR30 inner hemisphere are the greatest stresses on spherical surface of lithium hydride samples. • The radial residual stress σ{sub r} of SR40 hyper-hemispherical and SR30 inner hemispherical sample is compressive stress and the circumferential residual stress σ{sub t} is tensile stress. - Abstract: The released strains of sintered and machined lithium hydride of SR40 hyper-hemispherical and SR30 inner hemispherical sample could be shown in the measuring process by blind-hole method. The residual stresses of lithium hydride sample were calculated with the formulas of residual stress and released strains. The results show that the nearly 45 degrees direction residual stresses of SR40 hyper-hemisphere and SR30 inner hemisphere are the greatest stresses on spherical surface of lithium hydride samples. The radial residual stress σ{sub r} of SR40 hyper-hemispherical and SR30 inner hemispherical sample is compressive stress and the circumferential residual stress σ{sub t} is tensile stress.

  16. 40 CFR 141.25 - Analytical methods for radioactivity.

    Science.gov (United States)

    2010-07-01

    .... 141.25 Section 141.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Monitoring and Analytical Requirements... Spectrometry 901.1 p. 92 7120, 7120-97 D4785-93, 00a 4.5.2.3 Radioactive Strontium 89, 90 Radiochemical 905.0 p...

  17. Laser: a Tool for Optimization and Enhancement of Analytical Methods

    Energy Technology Data Exchange (ETDEWEB)

    Preisler, Jan [Iowa State Univ., Ames, IA (United States)

    1997-01-01

    In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable determination of plume velocities even when they are very high. Static scattering detection reveals negative influence of particle spallation on MS signal. Ion formation during MALD was monitored using 193-nm light to photodissociate a portion of insulin ion plume. These results define the optimal conditions for desorbing analytes from matrices, as opposed to achieving a compromise between efficient desorption and efficient ionization as is practiced in mass spectrometry. In CE experiment, we examined changes in a poly(ethylene oxide) (PEO) coating by continuously monitoring the electroosmotic flow (EOF) in a fused-silica capillary during electrophoresis. An imaging CCD camera was used to follow the motion of a fluorescent neutral marker zone along the length of the capillary excited by 488-nm Ar-ion laser. The PEO coating was shown to reduce the velocity of EOF by more than an order of magnitude compared to a bare capillary at pH 7.0. The coating protocol was important, especially at an intermediate pH of 7.7. The increase of p

  18. Measurement of capillary permeability in canine heart determined by the tissue injection, residue detection method

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Paaske, W P; Haunsø, S

    1991-01-01

    In previous studies the tissue injection, residue detection method failed to provide results of diffusional capillary permeability comparable to those of other methods. For this reason we reconsidered the kinetic theory and found that it is necessary to take into account the apparent (restricted...... (apparent) interstitial volume of distribution, tev is the mean transit time of the indicator, and klo is the recorded fractional initial washout rate constant. In experiments on open chest dog hearts we examined capillary permeability for 51Cr-EDTA and 99mTc-DTPA with the tissue injection, residue...... detection method and the single injection, residue detection method. Blood flow was measured independently with local 133Xenon washout. D and D' were measured by a true transient diffusion method. We found that the tissue injection, residue detection method gave results for capillary extraction and Pd...

  19. Measurement of capillary permeability in canine heart determined by the tissue injection, residue detection method

    DEFF Research Database (Denmark)

    Svendsen, J H; Paaske, William P; Haunsø, S

    1991-01-01

    detection method and the single injection, residue detection method. Blood flow was measured independently with local 133Xenon washout. D and D' were measured by a true transient diffusion method. We found that the tissue injection, residue detection method gave results for capillary extraction and Pd......In previous studies the tissue injection, residue detection method failed to provide results of diffusional capillary permeability comparable to those of other methods. For this reason we reconsidered the kinetic theory and found that it is necessary to take into account the apparent (restricted...... (apparent) interstitial volume of distribution, tev is the mean transit time of the indicator, and klo is the recorded fractional initial washout rate constant. In experiments on open chest dog hearts we examined capillary permeability for 51Cr-EDTA and 99mTc-DTPA with the tissue injection, residue...

  20. Improvements in the analytical methodology for the residue determination of the herbicide glyphosate in soils by liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Botero-Coy, A M; Ibáñez, M; Sancho, J V; Hernández, F

    2013-05-31

    The determination of glyphosate (GLY) in soils is of great interest due to the widespread use of this herbicide and the need of assessing its impact on the soil/water environment. However, its residue determination is very problematic especially in soils with high organic matter content, where strong interferences are normally observed, and because of the particular physico-chemical characteristics of this polar/ionic herbicide. In the present work, we have improved previous LC-MS/MS analytical methodology reported for GLY and its main metabolite AMPA in order to be applied to "difficult" soils, like those commonly found in South-America, where this herbicide is extensively used in large areas devoted to soya or maize, among other crops. The method is based on derivatization with FMOC followed by LC-MS/MS analysis, using triple quadrupole. After extraction with potassium hydroxide, a combination of extract dilution, adjustment to appropriate pH, and solid phase extraction (SPE) clean-up was applied to minimize the strong interferences observed. Despite the clean-up performed, the use of isotope labelled glyphosate as internal standard (ILIS) was necessary for the correction of matrix effects and to compensate for any error occurring during sample processing. The analytical methodology was satisfactorily validated in four soils from Colombia and Argentina fortified at 0.5 and 5mg/kg. In contrast to most LC-MS/MS methods, where the acquisition of two transitions is recommended, monitoring all available transitions was required for confirmation of positive samples, as some of them were interfered by unknown soil components. This was observed not only for GLY and AMPA but also for the ILIS. Analysis by QTOF MS was useful to confirm the presence of interferent compounds that shared the same nominal mass of analytes as well as some of their main product ions. Therefore, the selection of specific transitions was crucial to avoid interferences. The methodology developed

  1. Analytical method of seafloor crustal deformation corresponding to the large scale ocean current region

    Science.gov (United States)

    Yasuda, K.; Tadokoro, K.; Matsuhiro, K.

    2015-12-01

    We monitor seafloor crustal deformation at two observation points (south and north of Nankai Trough (TOA and TCA)) across the Nankai Trough, Japan, from 2013 to 2015. A ocean current flows frequently above our points called the Kuroshio current that has temperature difference perpendicular to the flow axis down to 1000 m in depths. Sound speed in the water depends on temperature (Del Grosso, 1974). Determination of seafloor benchmark position (SBP) has a bias when the sound speed structure includes a horizontal inhomogeneity (HI) in large-scale ocean current area. This bias is caused by trade-off between estimated spatial-temporal variation of sound speed structure and SBP. In this study, we propose a new observation system and analytical method, which directly observe the HI of sound speed derived from Underway CTD (UCTD) measurement and we introduce the HI to analytical method. We performed the observation in May 2015. We measured acoustic ranging during marine navigation on a circle with radius of 2 miles. At the same time, we observed six UCTD measurements down to 700 m in depths at both points. We use analytical method of Ikuta et al. (2008) for determination of SBP and adopt estimated HI of sound speed structure from UCTD measurements. We use the following equation to adopt the HI model: S(t,x,X)=S(t)+ΔS(R(X)+ar(x,X)), where S(t,x,X) is the spatial-temporal variation of slowness but spatial variation is the uniform during the observation period, S(t) is the estimated temporal variation of sound speed structure following Ikuta et al. (2008), ΔS is the horizontal gradient of slowness estimated from UCTD measurement, R(x) is the distance of a ship from center of three SBPs, r(x,X) is the distance between ship position and benchmark position, a is the ratio of layer of HI for the whole depth, x is the ship position, and X is the benchmark position. SBP adopted the HI model is determined 74.9 cm toward N17.4˚E at TCA and 90.0 cm toward N7.8˚E at TOA. The

  2. An adjoint method of sensitivity analysis for residual vibrations of structures subject to impacts

    Science.gov (United States)

    Yan, Kun; Cheng, Gengdong

    2018-03-01

    For structures subject to impact loads, the residual vibration reduction is more and more important as the machines become faster and lighter. An efficient sensitivity analysis of residual vibration with respect to structural or operational parameters is indispensable for using a gradient based optimization algorithm, which reduces the residual vibration in either active or passive way. In this paper, an integrated quadratic performance index is used as the measure of the residual vibration, since it globally measures the residual vibration response and its calculation can be simplified greatly with Lyapunov equation. Several sensitivity analysis approaches for performance index were developed based on the assumption that the initial excitations of residual vibration were given and independent of structural design. Since the resulting excitations by the impact load often depend on structural design, this paper aims to propose a new efficient sensitivity analysis method for residual vibration of structures subject to impacts to consider the dependence. The new method is developed by combining two existing methods and using adjoint variable approach. Three numerical examples are carried out and demonstrate the accuracy of the proposed method. The numerical results show that the dependence of initial excitations on structural design variables may strongly affects the accuracy of sensitivities.

  3. Evaluation of machining effect for the residual stress of SA508 by hole drilling method

    International Nuclear Information System (INIS)

    Lee, Jeong Kun; Lee, Kyoung Soo; Song, Ki O; Kim, Young Shin

    2009-01-01

    Residual stresses on a surface of the material are welcome or undesirable since it's direction, compression or tensile. But especially for the fatigue, it is not negligible effect on the material strength. These residual stresses developed during the manufacturing processes involving material deformation, heat treatment, machining. The object of this paper is verifying the effect of machining what is mostly used for SA508. For verifying the effect of machining, three different kind of machining have been achieved, milling, grinding, wire cutting. Also to measure the residual stress, hole drill method and indentation method are used.

  4. Numerical methods for calculating thermal residual stresses and hydrogen diffusion

    International Nuclear Information System (INIS)

    Leblond, J.B.; Devaux, J.; Dubois, D.

    1983-01-01

    Thermal residual stresses and hydrogen concentrations are two major factors intervening in cracking phenomena. These parameters were numerically calculated by a computer programme (TITUS) using the FEM, during the deposition of a stainless clad on a low-alloy plate. The calculation was performed with a 2-dimensional option in four successive steps: thermal transient calculation, metallurgical transient calculation (determination of the metallurgical phase proportions), elastic-plastic transient (plain strain conditions), hydrogen diffusion transient. Temperature and phase dependence of hydrogen diffusion coefficient and solubility constant. The following results were obtained: thermal calculations are very consistent with experiments at higher temperatures (due to the introduction of fusion and solidification latent heats); the consistency is not as good (by 70 degrees) for lower temperatures (below 650 degrees C); this was attributed to the non-introduction of gamma-alpha transformation latent heat. The metallurgical phase calculation indicates that the heat affected zone is almost entirely transformed into bainite after cooling down (the martensite proportion does not exceed 5%). The elastic-plastic calculations indicate that the stresses in the heat affected zone are compressive or slightly tensile; on the other hand, higher tensile stresses develop on the boundary of the heat affected zone. The transformation plasticity has a definite influence on the final stress level. The return of hydrogen to the clad during the bainitic transformation is but an incomplete phenomenon and the hydrogen concentration in the heat affected zone after cooling down to room temperature is therefore sufficient to cause cold cracking (if no heat treatment is applied). Heat treatments are efficient in lowering the hydrogen concentration. These results enable us to draw preliminary conclusions on practical means to avoid cracking. (orig.)

  5. Introduction to Validation of Analytical Methods: Potentiometric Determination of CO[subscript 2

    Science.gov (United States)

    Hipólito-Nájera, A. Ricardo; Moya-Hernandez, M. Rosario; Gomez-Balderas, Rodolfo; Rojas-Hernandez, Alberto; Romero-Romo, Mario

    2017-01-01

    Validation of analytical methods is a fundamental subject for chemical analysts working in chemical industries. These methods are also relevant for pharmaceutical enterprises, biotechnology firms, analytical service laboratories, government departments, and regulatory agencies. Therefore, for undergraduate students enrolled in majors in the field…

  6. A comparison between analytic and numerical methods for modelling automotive dissipative silencers with mean flow

    Science.gov (United States)

    Kirby, R.

    2009-08-01

    Identifying an appropriate method for modelling automotive dissipative silencers normally requires one to choose between analytic and numerical methods. It is common in the literature to justify the choice of an analytic method based on the assumption that equivalent numerical techniques are more computationally expensive. The validity of this assumption is investigated here, and the relative speed and accuracy of two analytic methods are compared to two numerical methods for a uniform dissipative silencer that contains a bulk reacting porous material separated from a mean gas flow by a perforated pipe. The numerical methods are developed here with a view to speeding up transmission loss computation, and are based on a mode matching scheme and a hybrid finite element method. The results presented demonstrate excellent agreement between the analytic and numerical models provided a sufficient number of propagating acoustic modes are retained. However, the numerical mode matching method is shown to be the fastest method, significantly outperforming an equivalent analytic technique. Moreover, the hybrid finite element method is demonstrated to be as fast as the analytic technique. Accordingly, both numerical techniques deliver fast and accurate predictions and are capable of outperforming equivalent analytic methods for automotive dissipative silencers.

  7. Analytical methods for the evaluation of melamine contamination.

    Science.gov (United States)

    Cantor, Stuart L; Gupta, Abhay; Khan, Mansoor A

    2014-02-01

    There is an urgent need for the analysis of melamine in the global pharmaceutical supply chain to detect economically motivated adulteration or unintentional contamination using a simple, nondestructive analytical technique that confirms the extent of adulteration in a shorter time period. In this work, different analytical techniques (thermal analysis, X-ray diffraction, Fourier transform infrared (FT-IR), FT-Raman, and near-infrared (NIR) spectroscopy) were evaluated for their ability to detect a range of melamine levels in gelatin. While FT-IR and FT-Raman provided qualitative assessment of melamine contamination or adulteration, powder X-ray diffraction and NIR were able to detect and quantify the presence of melamine at levels as low as 1.0% w/w. Multivariate analysis of the NIR data yielded the most accurate model when three principal components were used. Data were pretreated using standard normal variate transformation to remove multiplicative interferences of scatter and particle size. The model had a root-mean-square error of calibration of 2.4 (R(2) = 0.99) and root-mean square error of prediction of 2.5 (R(2) = 0.96). The value of the paired t test for actual and predicted samples (1%-50% w/w) was 0.448 (p 5), further indicating the robustness of the model. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  8. Analytical Method (M) - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Metabol...lsdba.nbdc01324-003 Description of data contents Information about methods of instrumental analysis. Data file File name: metabol...onote_analytical_method.zip File URL: ftp://ftp.biosciencedbc.jp/archive/metabolonote/LATEST/metabol...://togodb.biosciencedbc.jp/togodb/view/metabolonote_analytical_method#en Data acquisition method - Data anal...his Database Site Policy | Contact Us Analytical Method (M) - Metabolonote | LSDB Archive ...

  9. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  10. A Multifeatures Fusion and Discrete Firefly Optimization Method for Prediction of Protein Tyrosine Sulfation Residues.

    Science.gov (United States)

    Guo, Song; Liu, Chunhua; Zhou, Peng; Li, Yanling

    2016-01-01

    Tyrosine sulfation is one of the ubiquitous protein posttranslational modifications, where some sulfate groups are added to the tyrosine residues. It plays significant roles in various physiological processes in eukaryotic cells. To explore the molecular mechanism of tyrosine sulfation, one of the prerequisites is to correctly identify possible protein tyrosine sulfation residues. In this paper, a novel method was presented to predict protein tyrosine sulfation residues from primary sequences. By means of informative feature construction and elaborate feature selection and parameter optimization scheme, the proposed predictor achieved promising results and outperformed many other state-of-the-art predictors. Using the optimal features subset, the proposed method achieved mean MCC of 94.41% on the benchmark dataset, and a MCC of 90.09% on the independent dataset. The experimental performance indicated that our new proposed method could be effective in identifying the important protein posttranslational modifications and the feature selection scheme would be powerful in protein functional residues prediction research fields.

  11. In-house method validation and occurrence of alpha-, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone and trifluralin residues in strawberry

    Directory of Open Access Journals (Sweden)

    Alexandre Augusto Soares

    2013-12-01

    Full Text Available A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8% had residues of unauthorized pesticide for the culture of strawberry, one (0.5% had residues above the maximum residue limit, and another one (0.5% exhibited both non-conformities.

  12. Is residual memory variance a valid method for quantifying cognitive reserve? A longitudinal application.

    Science.gov (United States)

    Zahodne, Laura B; Manly, Jennifer J; Brickman, Adam M; Narkhede, Atul; Griffith, Erica Y; Guzman, Vanessa A; Schupf, Nicole; Stern, Yaakov

    2015-10-01

    Cognitive reserve describes the mismatch between brain integrity and cognitive performance. Older adults with high cognitive reserve are more resilient to age-related brain pathology. Traditionally, cognitive reserve is indexed indirectly via static proxy variables (e.g., years of education). More recently, cross-sectional studies have suggested that reserve can be expressed as residual variance in episodic memory performance that remains after accounting for demographic factors and brain pathology (whole brain, hippocampal, and white matter hyperintensity volumes). The present study extends these methods to a longitudinal framework in a community-based cohort of 244 older adults who underwent two comprehensive neuropsychological and structural magnetic resonance imaging sessions over 4.6 years. On average, residual memory variance decreased over time, consistent with the idea that cognitive reserve is depleted over time. Individual differences in change in residual memory variance predicted incident dementia, independent of baseline residual memory variance. Multiple-group latent difference score models revealed tighter coupling between brain and language changes among individuals with decreasing residual memory variance. These results suggest that changes in residual memory variance may capture a dynamic aspect of cognitive reserve and could be a useful way to summarize individual cognitive responses to brain changes. Change in residual memory variance among initially non-demented older adults was a better predictor of incident dementia than residual memory variance measured at one time-point. Copyright © 2015. Published by Elsevier Ltd.

  13. Comparison of Influenza Virus Particle Purification Using Magnetic Sulfated Cellulose Particles with an Established Centrifugation Method for Analytics.

    Science.gov (United States)

    Serve, Anja; Pieler, Michael Martin; Benndorf, Dirk; Rapp, Erdmann; Wolff, Michael Werner; Reichl, Udo

    2015-11-03

    A method for the purification of influenza virus particles using novel magnetic sulfated cellulose particles is presented and compared to an established centrifugation method for analytics. Therefore, purified influenza A virus particles from adherent and suspension MDCK host cell lines were characterized on the protein level with mass spectrometry to compare the viral and residual host cell proteins. Both methods allowed one to identify all 10 influenza A virus proteins, including low-abundance proteins like the matrix protein 2 and nonstructural protein 1, with a similar impurity level of host cell proteins. Compared to the centrifugation method, use of the novel magnetic sulfated cellulose particles reduced the influenza A virus particle purification time from 3.5 h to 30 min before mass spectrometry analysis.

  14. A manual of analytical methods used at MINTEK

    International Nuclear Information System (INIS)

    Stoch, H.; Dixon, K.

    1983-01-01

    The manual deals with various methods for a wide range of elemental analysis. Some of the methods that are used, include atomic absorption spectroscopy, optical emission spectroscopy and x-ray fluoresence spectroscopy. The basic charateristics of the method are given and the procedures are recorded step by step. One of the sections deals with methods associated with the recovery of uranium

  15. Gas Chromatographic Method: Tool for Rapid and Sensitive Analysis of Residual Solvents in Amoxicillin and Ampicillin Tablets

    Directory of Open Access Journals (Sweden)

    Sk Manirul Haque

    2015-12-01

    Full Text Available A simple and sensitive static head space gas chromatographic (SH-GC method equipped with FID has been developed and validated for simultaneous determination of residual solvents e.g.,  methanol, dichloromethane and toluene in two therapeutic drugs such as amoxicillin  and ampicillin. The separation was achieved with 30 m long Elite - 5 fused silica capillary column and 0.32 mm inner diameter. The developed SH-GC method offered symmetric peak shape, good resolution and reasonable retention time for all the solvents. Beer’s law was obeyed in the concentration ranges 100 – 1200, 50 – 1000 and 50 – 500 ppm for methanol, dichloromethane and toluene, respectively. The method was validated according to international conference on harmonization (ICH guidelines in terms of specificity, linearity, precision, accuracy, limit of detection, limit of quantitation, robustness and solution stability. The degrees of linearity of the calibration curves, the percent recoveries, relative standard deviation for the method were also determined. All the validation parameters were within the acceptable range. The developed SH-GC method could, therefore, be suitable for simple and rapid detection of trace levels residual solvents in other pharmaceutical products and thereby it could be used for routine analysis in any analytical laboratory.

  16. Intercalibration of analytical methods on marine environmental samples

    International Nuclear Information System (INIS)

    1985-10-01

    The analytical results reported by the 55 laboratories from 29 countries participating in this intercomparison have enabled to certify the concentration of 16 elements (As, Br, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Na, Rb, Se, Sr, Zn) in the mussel homogenate MA-M-2/TM. Information values could be established for 6 additional elements (Ag, Au, Cl, Pb, Sb, Sc). The atomic absorption spectroscopy was predominantly used in this intercomparison (45% of all determinations). It was followed by neutron activation analysis (28%), atomic emission spectroscopy (15%) and X-ray fluorescence (5%). The total number of outliers was moderate: 11.7% of all results. The number of outlying results by participating laboratories varied between 0 and 6

  17. Capillary-driven microfluidic paper-based analytical devices for lab on a chip screening of explosive residues in soil.

    Science.gov (United States)

    Ueland, Maiken; Blanes, Lucas; Taudte, Regina V; Stuart, Barbara H; Cole, Nerida; Willis, Peter; Roux, Claude; Doble, Philip

    2016-03-04

    A novel microfluidic paper-based analytical device (μPAD) was designed to filter, extract, and pre-concentrate explosives from soil for direct analysis by a lab on a chip (LOC) device. The explosives were extracted via immersion of wax-printed μPADs directly into methanol soil suspensions for 10min, whereby dissolved explosives travelled upwards into the μPAD circular sampling reservoir. A chad was punched from the sampling reservoir and inserted into a LOC well containing the separation buffer for direct analysis, avoiding any further extraction step. Eight target explosives were separated and identified by fluorescence quenching. The minimum detectable amounts for all eight explosives were between 1.4 and 5.6ng with recoveries ranging from 53-82% from the paper chad, and 12-40% from soil. This method provides a robust and simple extraction method for rapid identification of explosives in complex soil samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A comparison of residual stresses in built-up steel beams using hole-drilling method

    International Nuclear Information System (INIS)

    Nawafleh, M. A.; Hunaiti, Y. M.; Younes, R. M.

    2009-01-01

    Residual stresses have a significant effect on the stability resistance of metal building systems. An experimental program was conducted to measure these stresses in built-up steel beams using incremental hole-drilling method. The experimental results reveal that the predicted residual stress type of pattern for built-up I-sections with fillet welds on one side of the web is not the same as the pattern of residual stresses in built-up I-sections with fillet welds on both sides of the web

  19. Investigation by perturbative and analytical method of electronic properties of square quantum well under electric field

    Directory of Open Access Journals (Sweden)

    Mustafa Kemal BAHAR

    2010-06-01

    Full Text Available In this study, the effects of applied electric field on the isolated square quantum well was investigated by analytic and perturbative method. The energy eigen values and wave functions in quantum well were found by perturbative method. Later, the electric field effects were investigated by analytic method, the results of perturbative and analytic method were compared. As well as both of results fit with each other, it was observed that externally applied electric field changed importantly electronic properties of the system.

  20. Calculation method for residual stress analysis of filament-wound spherical pressure vessels

    International Nuclear Information System (INIS)

    Knight, C.E. Jr.

    1976-01-01

    Filament wound spherical pressure vessels may be produced with very high performance factors. These performance factors are a calculation of contained pressure times enclosed volume divided by structure weight. A number of parameters are important in determining the level of performance achieved. One of these is the residual stress state in the fabricated unit. A significant level of an unfavorable residual stress state could seriously impair the performance of the vessel. Residual stresses are of more concern for vessels with relatively thick walls and/or vessels constructed with the highly anisotropic graphite or aramid fibers. A method is established for measuring these stresses. A theoretical model of the composite structure is required. Data collection procedures and techniques are developed. The data are reduced by means of the model and result in the residual stress analysis. The analysis method can be used in process parameter studies to establish the best fabrication procedures

  1. The Method of Validity Evaluation of Hard Coal Excavation in Residual Seam Parts

    Science.gov (United States)

    Wodarski, Krzysztof; Bijańska, Jolanta; Gumiński, Adam

    2017-12-01

    The excavation of residual seam parts should be justified by positive assessment of the purposefulness, technical feasibility and economic effectiveness. The results of the profitability evaluation are crucial in a decision making process. The excavation of residual seam parts, even if it is possible from a technical point of view, should not be implemented if it is economically inefficient or when accompanied by a very high risk of non-recovery of invested capital resources. The article presents the evaluation method of possibilities of excavating hard coal from residual seam parts, and the example of its use in one of collieries in the Upper Silesian Coal Basin. Working in line with the developed method, allows to indicate the variant of residual seam part exploitation, which is feasible to implement from a technical point of view, and which is characterized by the highest economic effectiveness and lowest risk.

  2. Residual stresses in LENS[reg] components using neutron diffraction and contour method

    International Nuclear Information System (INIS)

    Rangaswamy, P.; Griffith, M.L.; Prime, M.B.; Holden, T.M.; Rogge, R.B.; Edwards, J.M.; Sebring, R.J.

    2005-01-01

    During manufacturing of components by laser engineered net shaping (LENS[reg]), a solid freeform fabrication process, the introduction of residual stresses causes deformation or in the worst case, cracking. The origin is attributed to thermal transients encountered during solidification. In the absence of reliable predictive models for the residual stresses, measurements are necessary. Residual stresses were measured in LENS[reg] samples of 316 stainless steel and Inconel 718 having simple geometrical shapes by both neutron diffraction and the contour methods. The results by the two methods are compared and discussed in the context of the growth direction during the LENS[reg] process. Surprisingly, the residual stresses are practically uni-axial, with high stresses in the growth direction

  3. A Novel Method to Decrease Micro-residual Stresses of Fibrous Composites by Adding Carbon Nanotube

    Directory of Open Access Journals (Sweden)

    M. M. Shokrieh

    2013-12-01

    Full Text Available In this research, a novel method to decrease micro-residual stresses of fibrous composites by adding carbon nanotubes (CNTs is proposed in detail. The negative coefficient of thermal expansion and the high young’s modulus of CNTs can be utilized to counterbalance the process induced residual stresses in composites. To this end, first, the effects of adding CNTs to the matrix of fibrous composites in reducing the coefficient of thermal expansion (CTE and increasing of young’s modulus of matrix are studied theoretically. Then, a three phase micromechanical model (the energy method is used to model the effect of CNT in reducing the residual stresses of fibrous composites. The results show that by addition of CNTs, enhancements in properties of matrix are obtained and lead to decrease in micro-residual stresses of matrix and fiber up to 72%.

  4. Feasibility of ultrasonic and eddy current methods for measurement of residual stress in shot peened metals

    International Nuclear Information System (INIS)

    Lavrentyev, Anton I.; Stucky, Paul A.; Veronesi, William A.

    2000-01-01

    Shot peening is a well-known method for extending the fatigue life of metal components by introducing compressive residual stresses near their surfaces. The capability to nondestructively evaluate the near surface residual stress would greatly aid the assurance of proper fatigue life in shot-peened components. This paper presents preliminary results from a feasibility study examining the use of ultrasonic and eddy current NDE methods for residual stress measurement in components where the stress has been introduced by shot peening. With an ultrasonic method, a variation of ultrasonic surface wave speed with shot peening intensity was measured. Near surface conductivity was measured by eddy current methods. Since the effective penetration depth of both methods employed is inversely related to the excitation frequency, by making measurements at different frequencies, each method has the potential to provide the stress-depth profile. Experiments were conducted on aluminum specimens (alloy 7075-T7351) peened within the Almen peening intensity range of 4C to 16C. The experimental results obtained demonstrate a correlation between peening intensity and Rayleigh wave velocity and between peening intensity and conductivity. The data suggests either of the methods may be suitable, with limitations, for detecting unsatisfactory levels of shot peening. Several factors were found to contribute to the measured responses: surface roughness, near surface plastic deformation (cold work) and residual stress. The contribution of each factor was studied experimentally. The feasibility of residual stress determination from the measured data is discussed

  5. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    HP

    Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with copper. Method: A coloured complex based on UV/Vis spectroscopic method was developed for the determination of losartan potassium concentration in pharmaceutical ...

  6. Body water compartments during bed rest: Evaluation of analytical methods

    Science.gov (United States)

    Young, H. L.; Juhos, L.; Castle, B. L.; Yusken, J.; Greenleaf, J. E.

    1973-01-01

    Nine healthy young men were studied to determine the reproducibility and interchangeability of the use of radio-iodinated human serum albumin and Evans Blue dye for estimating plasma volume, sodium bromide for extracellular fluid volume, and deuterium oxide for total body water volume. All subjects were tested in a semibasal condition and allowed to rest for at least 30 min. after arriving at the laboratory. The results indicate that there was uniform distribution of I131 and Evans Blue dye 10 min. after injection and of NaBr and D2O 3 hours after oral ingestion; the buildup of residual tracer did not interfere appreciably with the measurement of either or Evans Blue spaces when they are administered at equal intervals, and the buildup of background tracer after ingestion of NaBr and D2O once per week for three consecutive weeks did not affect the accuracy of the measurement. It was found that I131 and Evans Blue may be used interchangeably for estimating plasma volume; for estimating bromide and D2O spaces, one 3-hour equilibrium blood sample gives results similar to the extrapolation of multiple samples.

  7. Preliminary validation of high performance liquid chromatography method for detection of methyl-testosterone residue in carp muscle

    Science.gov (United States)

    Jiang, Jie; Lin, Hong; Fu, Xiaoting; Li, Mingming

    2005-07-01

    The use of synthetic anabolic steroid methyltestosterone (MT) as growth promoter is prohibited in China. Validations of analytical methods for MT residue in food and the results obtained have become indispensable. The high performance liquid chromatography (HPLC) method for the detection of MT with liquid-liquid extraction by trichloromethane-methanol in carp muscle tissue was preliminarily validated with reference to the following parameters: recovery (accuracy) at the 1, 5 and l0 mgkg-1 level, between-run and within-run CV values (repeatability, also called relative standard deviation (RSD)) and limit of detection. The recoveries were above 80% and the between-run and within-run CV values below 10% for muscle tissue. The limit of detection was 0.05 mgkg-1.

  8. Description of JNC's analytical method and its performance for FBR cores

    International Nuclear Information System (INIS)

    Ishikawa, M.

    2000-01-01

    The description of JNC's analytical method and its performance for FBR cores includes: an outline of JNC's Analytical System Compared with ERANOS; a standard data base for FBR Nuclear Design in JNC; JUPITER Critical Experiment; details of Analytical Method and Its Effects on JUPITER; performance of JNC Analytical System (effective multiplication factor k eff , control rod worth, and sodium void reactivity); design accuracy of a 600 MWe-class FBR Core. JNC developed a consistent analytical system for FBR core evaluation, based on JENDL library, f-table method, and three dimensional diffusion/transport theory, which includes comprehensive sensitivity tools to improve the prediction accuracy of core parameters. JNC system was verified by analysis of JUPITER critical experiment, and other facilities. Its performance can be judged quite satisfactory for FBR-core design work, though there is room for further improvement, such as more detailed treatment of cross-section resonance regions

  9. Application of an analytical method for solution of thermal hydraulic conservation equations

    Energy Technology Data Exchange (ETDEWEB)

    Fakory, M.R. [Simulation, Systems & Services Technologies Company (S3 Technologies), Columbia, MD (United States)

    1995-09-01

    An analytical method has been developed and applied for solution of two-phase flow conservation equations. The test results for application of the model for simulation of BWR transients are presented and compared with the results obtained from application of the explicit method for integration of conservation equations. The test results show that with application of the analytical method for integration of conservation equations, the Courant limitation associated with explicit Euler method of integration was eliminated. The results obtained from application of the analytical method (with large time steps) agreed well with the results obtained from application of explicit method of integration (with time steps smaller than the size imposed by Courant limitation). The results demonstrate that application of the analytical approach significantly improves the numerical stability and computational efficiency.

  10. Residual stress measurement of large scaled welded pipe using neutron diffraction method. Effect of SCC crack propagation and repair weld on residual stress distribution

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Katsuyama, Jinya; Tobita, Tohru; Morii, Yukio

    2011-01-01

    The RESA-1 neutron engineering diffractometer in the JRR-3 (Japan Research Reactor No.3) at the Japan Atomic Energy Agency, which is used for stress measurements, was upgraded to realize residual stress measurements of large scaled mechanical components. A series of residual stress measurements was made to obtain through-thickness residual stress distributions in a Type 304 stainless steel butt-welded pipe of 500A-sch.80 using the upgraded RESA-1 diffractometer. We evaluated effects of crack propagation such as stress corrosion cracking (SCC) and a part-circumference repair weld on the residual stress distributions induced by girth welding. Measured residual stress distributions near original girth weld revealed good agreement with typical results shown in some previous works using finite element method, deep hole drilling as well as neutron diffraction. After introducing a mock crack with 10 mm depth in the heat affected zone on the inside wall of the pipe by electro discharge machining, the axial residual stresses were found to be released in the part of the mock crack. However, changes in the through-wall bending stress component and the self-equilibrated stress component were negligible and hence the axial residual stress distribution in the ligament was remained in the original residual stresses near girth weld without the mock crack. Furthermore, changes in hoop and radial residual stress were also small. The residual stress distributions after a part repair welding on the outer circumference of the girth weld were significantly different from residual stress distributions near the original girth weld. The through-thickness average axial residual stress was increased due to increase of the tensile membrane stress and mitigation of the bending stress after repair welding. Throughout above studies, we evidenced that the neutron diffraction technique is useful and powerful tool for measuring residual stress distributions in large as well as thick mechanical

  11. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    Science.gov (United States)

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  12. An Analytical Method for Measuring Competence in Project Management

    Science.gov (United States)

    González-Marcos, Ana; Alba-Elías, Fernando; Ordieres-Meré, Joaquín

    2016-01-01

    The goal of this paper is to present a competence assessment method in project management that is based on participants' performance and value creation. It seeks to close an existing gap in competence assessment in higher education. The proposed method relies on information and communication technology (ICT) tools and combines Project Management…

  13. Analytical Method Details (MS) - Metabolonote | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us Metabol...l Analysis information). Data file File name: metabolonote_analytical_method_details.zip File URL: ftp://ftp....biosciencedbc.jp/archive/metabolonote/LATEST/metabolonote_analytical_method_details.zip File size: 73 KB Si...mple search URL http://togodb.biosciencedbc.jp/togodb/view/metabolonote_analytica...cription Download License Update History of This Database Site Policy | Contact Us Analytical Method Details (MS) - Metabolonote | LSDB Archive ...

  14. Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501.

    Science.gov (United States)

    Supak Smolcic, Vesna; Bilic-Zulle, Lidija; Fisic, Elizabeta

    2011-01-01

    Cobas 6000 (Roche, Germany) is biochemistry analyzer for spectrophotometric, immunoturbidimetric and ion-selective determination of biochemical analytes. Hereby we present analytical validation with emphasis on method performance judgment for routine operation. Validation was made for 30 analytes (metabolites, enzymes, trace elements, specific proteins and electrolytes). Research included determination of within-run (N = 20) and between-run imprecision (N = 30), inaccuracy (N = 30) and method comparison with routine analyzer (Beckman Coulter AU640) (N = 50). For validation of complete analytical process we calculated total error (TE). Results were judged according to quality specification criteria given by European Working Group. Within-run imprecision CVs were all below 5% except for cholesterol, triglycerides, IgA and IgM. Between-run CVs for all analytes were below 10%. Analytes that did not meet the required specifications for imprecision were: total protein, albumin, calcium, sodium, chloride, immunoglobulins and HDL cholesterol. Analytes that did not fulfill requirements for inaccuracy were: total protein, calcium, sodium and chloride. Analytes that deviated from quality specifications for total error were: total protein, albumin, calcium, sodium, chloride and IgM. Passing-Bablok regression analysis provided linear equation and 95% confidence interval for intercept and slope. Complete accordance with routine analyzer Beckman Coulter AU640 showed small number of analytes. Other analytes showed small proportional and/or small constant difference and therefore need to be adjusted for routine operation. Regarding low CV values, tested analyzer has satisfactory accuracy and precision and is extremely stable. Except for analytes that are coherent on both analyzers, some analytes require adjustments of slope and intercept for complete accordance.

  15. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  16. Analytic method for calculating properties of random walks on networks

    Science.gov (United States)

    Goldhirsch, I.; Gefen, Y.

    1986-01-01

    A method for calculating the properties of discrete random walks on networks is presented. The method divides complex networks into simpler units whose contribution to the mean first-passage time is calculated. The simplified network is then further iterated. The method is demonstrated by calculating mean first-passage times on a segment, a segment with a single dangling bond, a segment with many dangling bonds, and a looplike structure. The results are analyzed and related to the applicability of the Einstein relation between conductance and diffusion.

  17. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  18. Analytical Evaluation of Beam Deformation Problem Using Approximate Methods

    DEFF Research Database (Denmark)

    Barari, Amin; Kimiaeifar, A.; Domairry, G.

    2010-01-01

    The beam deformation equation has very wide applications in structural engineering. As a differential equation, it has its own problem concerning existence, uniqueness and methods of solutions. Often, original forms of governing differential equations used in engineering problems are simplified...

  19. 40 CFR 136.6 - Method modifications and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... must be dechlorinated prior to the addition of such salts. (iii) If the characteristics of a wastewater... matrices; as described in the ATP Protocol, after validation in nine distinct matrices, the method may be...

  20. EVALUATION OF ANALYTICAL METHODS FOR DETERMINING PESTICIDES IN BABY FOOD

    Science.gov (United States)

    Three extraction methods and two detection techniques for determining pesticides in baby food were evaluated. The extraction techniques examined were supercritical fluid extraction (SFE), enhanced solvent extraction (ESE), and solid phase extraction (SPE). The detection techni...

  1. Prevalence of antibiotic residues in commercial milk and its variation by season and thermal processing methods

    Directory of Open Access Journals (Sweden)

    Fathollah Aalipour

    2013-01-01

    Full Text Available Aims: In this study, the prevalence of antibiotic residues in pasteurized and sterilized commercial milk available in Shahre-kourd, Iran, was investigated. In addition, the influence of seasonal temperature changes on the prevalence of contamination was studied. Materials and Methods: Commercial milk samples of 187, including 154 pasteurized and 33 sterilized, milk samples were collected from the market between early January 2012 and late July of the same year. The presence of antibiotic residues was detected using the microbiological detection test kit, Eclipse 100, as a semi-quantitative method. Results: The results showed that 37 of the samples (19.8% have contained antibiotic residues above the European Union Maximum Residues Limits (EU-MRLs, of which 28 samples (14.97% were found to be contaminated but at the concentrations below the EU-MRLs. There was no significant difference between the contamination rate of pasteurized and Ultra High Temperature (UHT-sterilized samples. Similarly, variation of weather temperature with seasons had no effect on the contamination prevalence of milk samples ( P > 0.05. Conclusion: Based on the result of this study, antibiotics residues were present in the majority of milk samples. Neither the season nor the type of thermal processing of the commercial milks had noticeable impact on the prevalence level of the milk samples. However, an increasing trend of prevalence level for antibiotic residues was observed with increasing the temperature through the warm season.

  2. A fast analytical method for the addition of random variables

    International Nuclear Information System (INIS)

    Senna, V.; Milidiu, R.L.; Fleming, P.V.; Salles, M.R.; Oliveira, L.F.S. de

    1982-01-01

    Using the minimal cut sets representation of a fault tree, a new approach to the method of moments is proposed in order to estimate confidence bounds to the top event probability. The method utilizes two or three moments either to fit a distribution (the normal and lognormal families) or to evaluate bounds from standard inequalities (e.g. Markov, Tchebycheff, etc.). Examples indicate that the results obtained by the lognormal family are in good agreement with those obtained by Monte Carlo simulation. (Author) [pt

  3. Cluster Analytical Method of Fault Risk Analysis in Systems

    Science.gov (United States)

    Michaľčonok, German; Horalová Kalinová, Michaela

    2016-12-01

    In providing safety functions, the proposal of safety functions of control systems is an important part of a risk reduction strategy. In the specification of security requirements, it is necessary to determine and document individual characteristics and the desired performance level for each safety. This article presents the results of the experiment cluster analysis. The results of the experiment prove that the methods of cluster analysis provide a suitable tool for analyzing the reliability of safety systems analysis. Regarding the increasing complexity of the systems, we can state that the application of these methods in the subject area is a good choice.

  4. Fast analytical method for the addition of random variables

    International Nuclear Information System (INIS)

    Senna, V.; Milidiu, R.L.; Fleming, P.V.; Salles, M.R.; Oliveria, L.F.S.

    1983-01-01

    Using the minimal cut sets representation of a fault tree, a new approach to the method of moments is proposed in order to estimate confidence bounds to the top event probability. The method utilizes two or three moments either to fit a distribution (the normal and lognormal families) or to evaluate bounds from standard inequalities (e.g. Markov, Tchebycheff, etc.) Examples indicate that the results obtained by the log-normal family are in good agreement with those obtained by Monte Carlo simulation

  5. New Analytical Method for the Determination of Metronidazole in ...

    African Journals Online (AJOL)

    Methods: Metronidazole was extracted from human plasma through one step of protein precipitation by methanol using carbamazepine as internal standard (IS). After centrifugation of the plasma sample, the supernatant layer was separated and injected into HPLC system using Eclipse XDB-phenyl column. The mobile ...

  6. An Analytical framework of social learning facilitated by participatory methods

    NARCIS (Netherlands)

    Scholz, G.; Dewulf, A.; Pahl-Wostl, C.

    2014-01-01

    Social learning among different stakeholders is often a goal in problem solving contexts such as environmental management. Participatory methods (e.g., group model-building and role playing games) are frequently assumed to stimulate social learning. Yet understanding if and why this assumption is

  7. Analytic comparison of time- and frequency-domain electromagnetic methods

    Energy Technology Data Exchange (ETDEWEB)

    Stoyer, C.H.

    1980-01-01

    The time- and frequency-domain methods of electromagnetic geophysical prospecting are compared to determine the similarities and differences and to recommend system choices for particular field situations. Only the wire-loop configuration is considered, as this array is quite standard in geothermal prospecting. Comparisons are carried out using hardware and physical considerations, a large catalog of 3-layer model curves, 2D-3D model calculations, and by comparing Fourier transforms and layered inversions of field data from the Randsburg KGRA in California. The results generally indicate that frequency-domain methods offer better resolution and more practical hardware design for long-offset shallow applications. They also have a much better backup in terms of modelling tools for interpretation and history of experience. Transient methods are better suited for deeper probing, for both long- and short-offset applications. Frequency-domain methods are limited by the primary field, which is subject to distortion from near-surface inhomogeneites; this is also the case for early-time transients. Transient measurements in late time are limited by ambient electromagnetic noise and dynamic range of receiving equipment.

  8. Analytic Method for Pressure Recovery in Truncated Diffusers ...

    African Journals Online (AJOL)

    A prediction method is presented for the static pressure recovery in subsonic axisymmetric truncated conical diffusers. In the analysis, a turbulent boundary layer is assumed at the diffuser inlet and a potential core exists throughout the flow. When flow separation occurs, this approach cannot be used to predict the maximum ...

  9. Approximate Analytic Solutions for the Two-Phase Stefan Problem Using the Adomian Decomposition Method

    Directory of Open Access Journals (Sweden)

    Xiao-Ying Qin

    2014-01-01

    Full Text Available An Adomian decomposition method (ADM is applied to solve a two-phase Stefan problem that describes the pure metal solidification process. In contrast to traditional analytical methods, ADM avoids complex mathematical derivations and does not require coordinate transformation for elimination of the unknown moving boundary. Based on polynomial approximations for some known and unknown boundary functions, approximate analytic solutions for the model with undetermined coefficients are obtained using ADM. Substitution of these expressions into other equations and boundary conditions of the model generates some function identities with the undetermined coefficients. By determining these coefficients, approximate analytic solutions for the model are obtained. A concrete example of the solution shows that this method can easily be implemented in MATLAB and has a fast convergence rate. This is an efficient method for finding approximate analytic solutions for the Stefan and the inverse Stefan problems.

  10. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    Science.gov (United States)

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed.

  11. A new robust method for the treatment of analytical data

    International Nuclear Information System (INIS)

    Pearton, D.C.G.

    1982-01-01

    A new robust method is proposed for the calculation of the median and the relative standard deviation for a set of data containing unsymmetrically placed outliers. Examples of the advantages of the new method are given, the findings being confirmed by Monte Carlo tests. At Mintek mass-spectrometric data are often unsymmetrical, and all outliers are often at one of the extremities, either all high or all low. In some instances the outliers can be seen visually, and would therefore be rejected on sight. However, when large sets of results are processed, such as those from mass-spectrometric, X-ray fluorescence, and neutron-activation analyses, or in fields such as the assignment of values to reference materials, the sets of results are often too large for visual inspection and are processed within the computer

  12. [Molecular epidemiology of infectious diseases: analytical methods and results interpretation].

    Science.gov (United States)

    Sammarco, M L; Ripabelli, G; Tamburro, M

    2014-01-01

    Molecular typing and fingerprinting of microbial pathogens represent an essential tool for the epidemiological surveillance, outbreak detection and control of infectious diseases. Indeed, epidemiological investigation without genotyping data may not provide comprehensive information to allow the most appropriate interventions; despite this consideration, some barriers still hamper the routine application and interpretation of molecular typing data. In this paper, the most important methods currently used for characterization of pathogenic microorganisms for microbial source tracking and for the identification of clonal relationships among different isolates, are described according to their principles, advantages and limitations. Criteria for their evaluation and guidelines for the correct interpretation of results are also proposed. Molecular typing methods can be grouped into four categories based on different methodological principles, which include the characterization of restriction sites in genomic or plasmid DNA; the amplification of specific genetic targets; the restriction enzyme digestion and the subsequent amplification; sequence analysis. Although the development and the extensive use of molecular typing systems have greatly improved the understanding of the infectious diseases epidemiology, the rapid diversification, partial evaluation and lack of comparative data on the methods have raised significant questions about the selection of the most appropriate typing method, as well as difficulties for the lack of consensus about the interpretation of the results and nomenclature used for interpretation. Several criteria should be considered in order to evaluate the intrinsic performance and practical advantages of a typing system. However none of the available genotyping methods fully meets all these requirements. Therefore, the combined use of different approaches may lead to a more precise characterization and discrimination of isolates than a single

  13. A method of calculating the Jost function for analytic potentials

    International Nuclear Information System (INIS)

    Rakityansky, S.A.; Amos, K.

    1995-01-01

    A combination of the variable-constant and complex coordinate rotation methods is used to solve the two-body Schroedinger equation. The equation is replaced by a system of linear first-order differential equations, which enables one to perform direct calculation of the Jost function for all complex momenta of physical interest including the spectral points corresponding to bound and resonance states. 16 refs., 2 tabs., 2 figs

  14. Diclofenac quantification: analytical attributes of a spectrophotometric method

    OpenAIRE

    Monzón, Celina M.; Delfino, Mario R.; Sarno, María del C.; Delfino, Mario R. (h)

    2011-01-01

    An spectrophotometric UV-visible technique used to quantify diclofenac and its application to pharmaceutical preparations is described, based on diclofenac oxidation by Fe(III) in the presence of ophenanthroline. The formation of tris (o-phenanthroline)-Fe(II) complex (ferroin) upon diclofenac reaction was investigated. Absorbance of ferroin complex was measured at 506 nm. This method was tested on 50 mg tablets. Operating with placebos, it was found that excipients do not interfere with the ...

  15. Analytical methods applied to diverse types of Brazilian propolis

    Directory of Open Access Journals (Sweden)

    Marcucci Maria

    2011-06-01

    Full Text Available Abstract Propolis is a bee product, composed mainly of plant resins and beeswax, therefore its chemical composition varies due to the geographic and plant origins of these resins, as well as the species of bee. Brazil is an important supplier of propolis on the world market and, although green colored propolis from the southeast is the most known and studied, several other types of propolis from Apis mellifera and native stingless bees (also called cerumen can be found. Propolis is usually consumed as an extract, so the type of solvent and extractive procedures employed further affect its composition. Methods used for the extraction; analysis the percentage of resins, wax and insoluble material in crude propolis; determination of phenolic, flavonoid, amino acid and heavy metal contents are reviewed herein. Different chromatographic methods applied to the separation, identification and quantification of Brazilian propolis components and their relative strengths are discussed; as well as direct insertion mass spectrometry fingerprinting. Propolis has been used as a popular remedy for several centuries for a wide array of ailments. Its antimicrobial properties, present in propolis from different origins, have been extensively studied. But, more recently, anti-parasitic, anti-viral/immune stimulating, healing, anti-tumor, anti-inflammatory, antioxidant and analgesic activities of diverse types of Brazilian propolis have been evaluated. The most common methods employed and overviews of their relative results are presented.

  16. Analytical models approximating individual processes: a validation method.

    Science.gov (United States)

    Favier, C; Degallier, N; Menkès, C E

    2010-12-01

    Upscaling population models from fine to coarse resolutions, in space, time and/or level of description, allows the derivation of fast and tractable models based on a thorough knowledge of individual processes. The validity of such approximations is generally tested only on a limited range of parameter sets. A more general validation test, over a range of parameters, is proposed; this would estimate the error induced by the approximation, using the original model's stochastic variability as a reference. This method is illustrated by three examples taken from the field of epidemics transmitted by vectors that bite in a temporally cyclical pattern, that illustrate the use of the method: to estimate if an approximation over- or under-fits the original model; to invalidate an approximation; to rank possible approximations for their qualities. As a result, the application of the validation method to this field emphasizes the need to account for the vectors' biology in epidemic prediction models and to validate these against finer scale models. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. A method to evaluate residual phase error for polar formatted synthetic aperture radar systems

    Science.gov (United States)

    Musgrove, Cameron; Naething, Richard

    2013-05-01

    Synthetic aperture radar systems that use the polar format algorithm are subject to a focused scene size limit inherent to the polar format algorithm. The classic focused scene size limit is determined from the dominant residual range phase error term. Given the many sources of phase error in a synthetic aperture radar, a system designer is interested in how much phase error results from the assumptions made with the polar format algorithm. Autofocus algorithms have limits to the amount and type of phase error that can be corrected. Current methods correct only one or a few terms of the residual phase error. A system designer needs to be able to evaluate the contribution of the residual or uncorrected phase error terms to determine the new focused scene size limit. This paper describes a method to estimate the complete residual phase error, not just one or a few of the dominant residual terms. This method is demonstrated with polar format image formation, but is equally applicable to other image formation algorithms. A benefit for the system designer is that additional correction terms can be added or deleted from the analysis as necessary to evaluate the resulting effect upon image quality.

  18. Determination of Profenofos Pesticidal Residue in Lettuce (Lactuca sativa L. by Gas Chromatographic Method

    Directory of Open Access Journals (Sweden)

    Yohannes Alen

    2015-05-01

    Full Text Available The determination of profenofos pesticidal residue in the lettuce (Lactuca sativa L. by using gas chromatography using flame photometric detector (FPD had been investigated. The lettuce was collected from Padang Luar area, Agam distric, West Sumatera. Sample for determination of profenofos residue divided into three groups: unwashed (A, washed with water (B, and washed with detergent (C. Maceration with sonication was used for the extraction using ethylacetateas a solvent. The results showed that profenofos pesticide residue in sample A, B and C were 0.204, 0.080 and 0.061 ppm, respectively. These profenofos pesticidal residue are over than the Maximum Residue Limits (MRL that established by The Japan Food Chemical Research Foundation (0.05 ppm even though World Health Organization (WHO has not established Maximum Residue Limits (MRL profenofos on lettuce. Based on the statistical analysis one-way method (Anova using SPSS 20.0 showed that there was a significant concentrations difference between lettuce A from lettuce B and lettuce C with p < 0.05.

  19. Residual nitrogen-15 recovery by corn as influenced by tillage and fertilization method

    International Nuclear Information System (INIS)

    Timmons, D.R.; Cruse, R.M.

    1991-01-01

    Tillage systems that create different surface residue conditions may also affect the recovery of residual fertilizer N during subsequent growing seasons. This study evaluated the recovery of residual labeled N fertilizer in the soil by corn (Zea mays L.) for two tillage systems and two fertilization methods. Five atom % 15 N-enriched 28% urea-ammonium nitrate solution (UAN) at 224 kg N ha -1 was either surface-applied in the fall before any primary tillage or banded (knifed in) just before planting in the spring. Continuous corn was grown with either fall moldboard-plow (MP) or ridge-till (RT) systems. After the initial growing season, the recovery of residual labeled N in the soil by corn was determined for three consecutive growing seasons, and the soil profile was sampled periodically to measure residual 15 N in the organic and inorganic pools. One year after labeled UAN application, from 16 to 27% of the initial 15 N applied was found in the organic N pool and only 1% as inorganic N[NH 4 +(NO 2 +NO 3 )-N]. After four seasons, residual 15 N in the organic N pool ranged from 13 to 24%. Less than 0.5% remained as inorganic N. Regression analyses indicated that about 5 kg 15 N ha -1 year -1 became available for both MP and RT systems with banded N, so the amounts were small. Total residual 15 N recovery by corn grain plus stover for three seasons ranged from 1.7 to 3.5%, and was greatest for spring-banded fertilizer. Because the amounts of residual 15 N utilized were too small to affect corn growth, this N source appears to be negligible when considering corn-N needs

  20. A Vocal-Based Analytical Method for Goose Behaviour Recognition

    Directory of Open Access Journals (Sweden)

    Henrik Karstoft

    2012-03-01

    Full Text Available Since human-wildlife conflicts are increasing, the development of cost-effective methods for reducing damage or conflict levels is important in wildlife management. A wide range of devices to detect and deter animals causing conflict are used for this purpose, although their effectiveness is often highly variable, due to habituation to disruptive or disturbing stimuli. Automated recognition of behaviours could form a critical component of a system capable of altering the disruptive stimuli to avoid this. In this paper we present a novel method to automatically recognise goose behaviour based on vocalisations from flocks of free-living barnacle geese (Branta leucopsis. The geese were observed and recorded in a natural environment, using a shielded shotgun microphone. The classification used Support Vector Machines (SVMs, which had been trained with labeled data. Greenwood Function Cepstral Coefficients (GFCC were used as features for the pattern recognition algorithm, as they can be adjusted to the hearing capabilities of different species. Three behaviours are classified based in this approach, and the method achieves a good recognition of foraging behaviour (86–97% sensitivity, 89–98% precision and a reasonable recognition of flushing (79–86%, 66–80% and landing behaviour(73–91%, 79–92%. The Support Vector Machine has proven to be a robust classifier for this kind of classification, as generality and non-linearcapabilities are important. We conclude that vocalisations can be used to automatically detect behaviour of conflict wildlife species, and as such, may be used as an integrated part of awildlife management system.

  1. Plastics in soil: Analytical methods and possible sources.

    Science.gov (United States)

    Bläsing, Melanie; Amelung, Wulf

    2018-01-15

    At least 300 Mio t of plastic are produced annually, from which large parts end up in the environment, where it persists over decades, harms biota and enters the food chain. Yet, almost nothing is known about plastic pollution of soil; hence, the aims of this work are to review current knowledge on i) available methods for the quantification and identification of plastic in soil, ii) the quantity and possible input pathways of plastic into soil, (including first preliminary screening of plastic in compost), and iii) its fate in soil. Methods for plastic analyses in sediments can potentially be adjusted for application to soil; yet, the applicability of these methods for soil needs to be tested. Consequently, the current data base on soil pollution with plastic is still poor. Soils may receive plastic inputs via plastic mulching or the application of plastic containing soil amendments. In compost up to 2.38-1200mg plastic kg -1 have been found so far; the plastic concentration of sewage sludge varies between 1000 and 24,000 plastic items kg -1 . Also irrigation with untreated and treated wastewater (1000-627,000 and 0-125,000 plastic items m -3 , respectively) as well as flooding with lake water (0.82-4.42 plastic items m -3 ) or river water (0-13,751 items km -2 ) can provide major input pathways for plastic into soil. Additional sources comprise littering along roads and trails, illegal waste dumping, road runoff as well as atmospheric input. With these input pathways, plastic concentrations in soil might reach the per mill range of soil organic carbon. Most of plastic (especially >1μm) will presumably be retained in soil, where it persists for decades or longer. Accordingly, further research on the prevalence and fate of such synthetic polymers in soils is urgently warranted. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Applications of Nuclear Analytical Methods for High Tech Industry

    International Nuclear Information System (INIS)

    Hossain, T.

    2013-01-01

    Silicon based semiconductor chip manufacturing is a worldwide high technology industry with numerous measurement issues. One of the major concerns in the semiconductor manufacturing is contamination such as the trace metal impurities. This concern is vividly illustrated by the fact that the manufacturing in this industry is done in ultra clean environment where the entire manufacturing facility or “Fab” is a clean room facility or each and every manufacturing tool is enclosed in a mini-environment Although semiconductor devices are fabricated on the surface of the Si wafers contamination in the bulk material is a major concern. Nuclear methods of analysis are uniquely suited for the contamination analysis in such a matrix. Many opportunities in the semiconductor manufacturing field exist for the nuclear methods to provide support services. Contamination analysis by NAA, depth profiles by NDP and prompt gamma analysis of H in thin films are a few examples. These needs are on-going and require commitment from the lab so that a manufacturing operation can rely on the delivery of these services when required

  3. An analytical method of estimating Value-at-Risk on the Belgrade Stock Exchange

    Directory of Open Access Journals (Sweden)

    Obadović Milica D.

    2009-01-01

    Full Text Available This paper presents market risk evaluation for a portfolio consisting of shares that are continuously traded on the Belgrade Stock Exchange, by applying the Value-at-Risk model - the analytical method. It describes the manner of analytical method application and compares the results obtained by implementing this method at different confidence levels. Method verification was carried out on the basis of the failure rate that demonstrated the confidence level for which this method was acceptable in view of the given conditions.

  4. Use of mass spectrometry methods as a strategy for detection and determination of residual solvents in pharmaceutical products.

    Science.gov (United States)

    Pérez Pavón, José Luis; del Nogal Sanchez, Miguel; García Pinto, Carmelo; Fernandez Laespada, M Esther; Moreno Cordero, Bernardo

    2006-07-15

    In the present work a strategy for the qualitative and quantitative analysis of residual solvents in pharmaceutical products is reported. First, a low-resolution chromatogram is generated for the identification of the solvents present in the samples by means of headspace generation-fast gas chromatography-mass spectrometry (HS-fast GC/MS). From the plotting of this information by means of contour plots with time and mass/charge axes, it is decided whether quantification of such compounds can be accomplished without chromatographic separation or whether it should be done by fast gas chromatography. The nonseparative method is based on direct coupling of a headspace sampler with a mass spectrometer (HS-MS) and requires a signal recording time of only 3 min, while with fast gas chromatography the time required to obtain a chromatogram is 7.16 min. The use of headspace generation for introducing the sample and standard addition as a quantification technique provided satisfactory results and minimized the matrix effect. An important advantage of the methodologies used here is related to the fact that no prior treatment of the sample is required, thus minimizing the creation of analytical artifacts and the errors associated with this step of the analytical process. The methods were applied to the determination of residual solvents in 27 different pharmaceutical products. Detection and quantitation limits were sufficiently low to enable the estimation of organic volatile impurities according to the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use.

  5. Analytical strategies for residue analysis of veterinary drugs and growth-promoting agents in food-producing animals - A review

    NARCIS (Netherlands)

    Stolker, A.A.M.; Brinkman, U.A.T.

    2005-01-01

    After a brief introduction into the field of veterinary drugs and growth-promoting agents, the most important EU regulations and directives for the inspection of food-producing animals and animal products regarding the residue control of these substances are presented and discussed. Main attention

  6. Colloids in PWR primary and secondary coolant. Innovative analytical methods

    International Nuclear Information System (INIS)

    Nowotka, Karsten; Guillodo, Michael; Burchardt, Carsten; Geier, Roland; Lehr, Robert; Stellwag, Bernhard

    2014-01-01

    Transport and deposition of corrosion products in the colloid size range between 1 nm and 1 μm are important for heat transfer performance and corrosion in primary and secondary cooling circuits of LWRs. Direct analysis of the properties of small-sized colloids (< 0.45 μm) is difficult due to the pronounced change of the physicochemical properties of coolant samples in sampling lines. An innovative method, based on a filter cascade and developed in the AREVA Technical Center, named 'Colloid Catcher' (CC, patent pending), permits on-line measurements of the properties of corrosion products in the coolant of LWRs. CC measurements are complementary to classic trace analysis addressing the soluble content. Low and high temperature (up to 330°C) test sections are available, depending on our customer's needs. The CC contains differential pressure detectors at each of the three consecutive membrane filters which allow for an in-situ characterization without modification of the corrosion products chemical nature due to temperature changes and subsequent exposure to the atmosphere. With this method, a 'Colloid Fingerprint' of the test solution can be obtained, ideal for an assessment of the transport and deposition of corrosion products in laboratory and on-site studies. The on-line data can of course be complemented by post filtration membrane characterization by digestion and/or optical methods. The high temperature CC serves at the same time as a sampling point for grab samples, with good reproducibility thanks to continuous liquid flow. The CC has been designed to be deployable on laboratory or industrial cooling circuits. The CC test sections have been qualified using AREVA Technical Center's test loops. First test results obtained with the LT CC are presented. Laboratory data can be used to back up existing results and data of on-site measurement campaigns at BWR and PWR plants which were determined with a basic version of the LT CC

  7. Evaluation of Methods for the Calculation of the pKa of Cysteine Residues in Proteins.

    Science.gov (United States)

    Awoonor-Williams, Ernest; Rowley, Christopher N

    2016-09-13

    Methods for the calculation of the pKa ionizable amino acids are valuable tools for understanding pH-dependent properties of proteins. Cysteine is unique among the amino acids because of the chemical reactivity of its thiol group (S-H), which plays an instrumental role in several biochemical and regulatory functions. The acidity of noncatalytic cysteine residues is a factor in their susceptibility to chemical modification. Despite the plethora of existing pKa computing methods, no definitive protocol exists for accurately calculating the pKa's of cysteine residues in proteins. A cysteine pKa test set was developed, which is comprised of 18 cysteine residues in 12 proteins where the pKa's have been determined experimentally and an experimental structure is available. The pKa's of these residues were calculated using three methods that use an implicit solvent model (H++, MCCE, and PROPKA) and an all-atom replica-exchange thermodynamic integration approach with the CHARMM36 and AMBER ff99SB-ILDNP force fields. The models that use implicit solvation methods were generally unreliable in predicting cysteine residue pKa's, with RMSDs between 3.41 and 4.72 pKa units. On average, the explicit solvent methods performed better than the implicit solvent methods. RMSD values of 2.40 and 3.20 were obtained for simulations with the CHARMM36 and AMBER ff99SB-ILDNP force fields, respectively. Further development of these methods is necessary because the performance of the best method is similar to that of the null-model (RMSD = 2.74) and these differences in RMSD are of limited statistical significance given the small size of our test set.

  8. Modelling of packet traffic with matrix analytic methods

    DEFF Research Database (Denmark)

    Andersen, Allan T.

    1995-01-01

    vot reveal any adverse behaviour. In fact the observed traffic seemed very close to what would be expected from Poisson traffic. The Changeover/Changeback procedure in SS7, which is used to redirect traffic in case of link failure, has been analyzed. The transient behaviour during a Changeover...... scenario was modelled using Markovian models. The Ordinary Differential Equations arising from these models were solved numerically. The results obtained seemed very similar to those obtained using a different method in previous work by Akinpelu & Skoog 1985. Recent measurement studies of packet traffic...... is found by noting the close relationship with the expressions for the corresponding infinite queue. For the special case of a batch Poisson arrival process this observation makes it possible to express the queue length at an arbitrary in terms of the corresponding queue lengths for the infinite case....

  9. Using an analytical geometry method to improve tiltmeter data presentation

    Science.gov (United States)

    Su, W.-J.

    2000-01-01

    The tiltmeter is a useful tool for geologic and geotechnical applications. To obtain full benefit from the tiltmeter, easy and accurate data presentations should be used. Unfortunately, the most commonly used method for tilt data reduction now may yield inaccurate and low-resolution results. This article describes a simple, accurate, and high-resolution approach developed at the Illinois State Geological Survey for data reduction and presentation. The orientation of tiltplates is determined first by using a trigonometric relationship, followed by a matrix transformation, to obtain the true amount of rotation change of the tiltplate at any given time. The mathematical derivations used for the determination and transformation are then coded into an integrated PC application by adapting the capabilities of commercial spreadsheet, database, and graphics software. Examples of data presentation from tiltmeter applications in studies of landfill covers, characterizations of mine subsidence, and investigations of slope stability are also discussed.

  10. Manual of analytical methods for the Environmental Health Laboratory

    International Nuclear Information System (INIS)

    Gray, C.E.

    1975-06-01

    The manual contains four sections: absorption spectrophotometry; general radiochemical procedures; instrumental analysis; and calibration of field instruments. Included in the individual analyses using absorption spectrophotometry is one for total iodine in oil. Radiochemical procedures are given for: actinides in urine and water; 137 Cs in soil and vegetation; 137 Cs in soil, urine, vegetation, and water; enriched uranium in urine; gross beta activity in soil, urine, vegetation, and water; plutonium in urine and soil; 210 Po in urine and water; 24 Na in air, blood, urine, and water; 90 Sr in soil, vegetation, and water; tritium in urine, water, and on swipes; and total uranium on fallout trays and in soil, urine, and water. Among the individual instrumental analyses is a spectrographic method for determining beryllium in air samples and swipes. (U.S.)

  11. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 4, Organic methods

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    This interim notice covers the following: extractable organic halides in solids, total organic halides, analysis by gas chromatography/Fourier transform-infrared spectroscopy, hexadecane extracts for volatile organic compounds, GC/MS analysis of VOCs, GC/MS analysis of methanol extracts of cryogenic vapor samples, screening of semivolatile organic extracts, GPC cleanup for semivolatiles, sample preparation for GC/MS for semi-VOCs, analysis for pesticides/PCBs by GC with electron capture detection, sample preparation for pesticides/PCBs in water and soil sediment, report preparation, Florisil column cleanup for pesticide/PCBs, silica gel and acid-base partition cleanup of samples for semi-VOCs, concentrate acid wash cleanup, carbon determination in solids using Coulometrics` CO{sub 2} coulometer, determination of total carbon/total organic carbon/total inorganic carbon in radioactive liquids/soils/sludges by hot persulfate method, analysis of solids for carbonates using Coulometrics` Model 5011 coulometer, and soxhlet extraction.

  12. Qualitative screening method for pesticide residues detection in fruits and vegetables

    Directory of Open Access Journals (Sweden)

    Iván Mauricio Huérfano Barco

    2018-01-01

    Full Text Available Because of the importance of developing methodologies that allow agricultural residues analysis, a rapid screening qualitative method for the determination of pesticides residues in fruits and vegetables was validated. The methodology was based on the European QuEChERS extraction method with an additional cleaning step by gel permeation chromatography (GPC, which helped to reduce the number of matrix components in the final extract. The analysis was carried out by gas chromatography coupled to mass spectrometry with a single quadrupole analyzer. The methodology was appropriate for the qualitative analysis of 31 pesticides at their respective maximum residue limits. Consistent results were obtained with respect to a quantitative routine methodology in the analysis of real samples, hence the methodology was proven to be a good alternative for the fast analysis of these contaminants in fruits and vegetables.

  13. Residues of Eight Antibiotics in Vegetable Soils Affected by Fertilization Methods

    Directory of Open Access Journals (Sweden)

    BAO Chen-yan

    2014-08-01

    Full Text Available Total forty-four representative soil samples were collected from vegetable fields in Hangzhou, Jiaxing, and Shaoxing city of Zhe-jiang Province for measuring concentrations of eight antibiotics, including chloroteracycline, tetracycline, oxytetracyline, enrofloxacin, sulfa-diazine, sulfamethazine, sulfamethoxazole, and tylosin. Effects of four fertilization methods(application of livestock and poultry manure, appli-cation of commercial organic fertilizer, application of biogas residue and application of chemical fertilizeron residues of the antibiotics in the soils were investigated. The results showed that the detection proportions and concentrations of the antibiotics in the soils varied with appli-cation methods of fertilizers and species of antibiotics. The concentration of chloroteracycline in the soils was much higher than those of other antibiotics. Mean percentage proportion of chloroteracycline in total residues of eight antibiotics was 67.03%. The detection proportions and concentrations of the antibiotics decreased in the sequence of chloroteracycline>sulfamethazine>enrofloxacin>tetracycline>sulfamethoxazole, tylosin>oxytetracycline>sulfadiazine. The detection proportion and concentration of the tetracyclines were greater than those of the sulfon-amides. The residues of the antibiotics in the soils applied with livestock and poultry manure were much greater than those of other vegetable soils, and the detection proportions and concentrations of the antibiotics in the soils decreased in the sequence of fields with application of livestock and poultry manure>fields with application of commercial organic fertilizer>fields with application of biogas residue>fields with ap-plication of chemical fertilizer. The results indicate that the livestock and poultry manure is the main source of antibiotics in vegetable soils, and application of commercial organic fertilizer and biogas residue also have certain contribution to antibiotics residues

  14. Analytical Quality by Design Approach to Test Method Development and Validation in Drug Substance Manufacturing

    Directory of Open Access Journals (Sweden)

    N. V. V. S. S. Raman

    2015-01-01

    Full Text Available Pharmaceutical industry has been emerging rapidly for the last decade by focusing on product Quality, Safety, and Efficacy. Pharmaceutical firms increased the number of product development by using scientific tools such as QbD (Quality by Design and PAT (Process Analytical Technology. ICH guidelines Q8 to Q11 have discussed QbD implementation in API synthetic process and formulation development. ICH Q11 guidelines clearly discussed QbD approach for API synthesis with examples. Generic companies are implementing QbD approach in formulation development and even it is mandatory for USFDA perspective. As of now there is no specific requirements for AQbD (Analytical Quality by Design and PAT in analytical development from all regulatory agencies. In this review, authors have discussed the implementation of QbD and AQbD simultaneously for API synthetic process and analytical methods development. AQbD key tools are identification of ATP (Analytical Target Profile, CQA (Critical Quality Attributes with risk assessment, Method Optimization and Development with DoE, MODR (method operable design region, Control Strategy, AQbD Method Validation, and Continuous Method Monitoring (CMM. Simultaneous implementation of QbD activities in synthetic and analytical development will provide the highest quality product by minimizing the risks and even it is very good input for PAT approach.

  15. Evaluation of Pentachlorophenol Residues in Some Hygienic Papers Prepared from Virgin and Secondary Pulp by Electron Capture Gas Chromatographic Method

    Directory of Open Access Journals (Sweden)

    Behrouz Akbari-adergani

    2016-01-01

    Full Text Available In this study, residual amount of pentachlorophenol (PCP as the most important paper preservative, which is extremely hazardous pollutant, was determined in some tissue papers and napkins. Twenty-five samples of two producing hygienic paper factories prepared from virgin and secondary pulp were analyzed for the presence of trace amount of PCP. The analytical procedure involved direct extraction of PCP from hygienic paper and its determination by gas chromatography with electron capture detection. The statistical results for the analysis of all samples revealed that there were significant differences between mean of PCP in hygienic papers prepared from virgin and secondary pulp (P<0.05. This method gave recoveries of 86-98% for hygienic paper made from virgin pulp and 79-92% for hygienic paper made from secondary pulp. The limit of detection (LOD and limit of quantification (LOQ for PCP were 6.3 and 21.0 mg/kg, respectively. The analytical method has the requisite sensitivity, accuracy, precision and specificity to assay PCP in hygienic papers. This study demonstrates a concern with exposition to PCP considering that hygienic paper is largely consumed in the society.

  16. Liquid chromatography – tandem mass spectrometry method for the determination of ten tetracycline residues in muscle samples

    Directory of Open Access Journals (Sweden)

    Gajda Anna

    2015-09-01

    Full Text Available A liquid chromatography – tandem mass spectrometry (LC-MS/MS method for the determination of oxytetracycline (OTC, 4-epi oxytetracycline (4-epi OTC, tetracycline (TC, 4-epi tetracycline (4-epi TC, chlortetracycline (CTC, 4-epi chlortetracycline (4-epi CTC, doxycycline (DC, minocycline (MINO, methacycline (META and rolitetracycline (ROLI residues in muscles was developed. The procedure consisted of an oxalic acid extraction followed by protein removal with trichloroacetic acid. Further solid phase clean-up on polymeric (Strata X reversed phase columns was performed to obtain an extract suitable for LC-MS/MS analysis. The tetracyclines were separated on a C 18 analytical column with mobile phase consisting of 0.01% formic acid in acetonitrile and 0.01% formic acid in water in gradient mode. The method was validated according to the Commission Decision 2002/657/EC. The recoveries of all target compounds were 91.8% – 103.6%. The decision limits were from 109.0 to 119.8 μg/kg and detection capability varied within the range of 122.2 to 137.6 μg/kg, depending on the analyte.

  17. Quadratic residues and non-residues selected topics

    CERN Document Server

    Wright, Steve

    2016-01-01

    This book offers an account of the classical theory of quadratic residues and non-residues with the goal of using that theory as a lens through which to view the development of some of the fundamental methods employed in modern elementary, algebraic, and analytic number theory. The first three chapters present some basic facts and the history of quadratic residues and non-residues and discuss various proofs of the Law of Quadratic Reciprosity in depth, with an emphasis on the six proofs that Gauss published. The remaining seven chapters explore some interesting applications of the Law of Quadratic Reciprocity, prove some results concerning the distribution and arithmetic structure of quadratic residues and non-residues, provide a detailed proof of Dirichlet’s Class-Number Formula, and discuss the question of whether quadratic residues are randomly distributed. The text is a valuable resource for graduate and advanced undergraduate students as well as for mathematicians interested in number theory.

  18. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    Science.gov (United States)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  19. Propulsion and launching analysis of variable-mass rockets by analytical methods

    Directory of Open Access Journals (Sweden)

    D.D. Ganji

    2013-09-01

    Full Text Available In this study, applications of some analytical methods on nonlinear equation of the launching of a rocket with variable mass are investigated. Differential transformation method (DTM, homotopy perturbation method (HPM and least square method (LSM were applied and their results are compared with numerical solution. An excellent agreement with analytical methods and numerical ones is observed in the results and this reveals that analytical methods are effective and convenient. Also a parametric study is performed here which includes the effect of exhaust velocity (Ce, burn rate (BR of fuel and diameter of cylindrical rocket (d on the motion of a sample rocket, and contours for showing the sensitivity of these parameters are plotted. The main results indicate that the rocket velocity and altitude are increased with increasing the Ce and BR and decreased with increasing the rocket diameter and drag coefficient.

  20. A SIMPLE ANALYTICAL METHOD TO DETERMINE SOLAR ENERGETIC PARTICLES' MEAN FREE PATH

    International Nuclear Information System (INIS)

    He, H.-Q.; Qin, G.

    2011-01-01

    To obtain the mean free path of solar energetic particles (SEPs) for a solar event, one usually has to fit time profiles of both flux and anisotropy from spacecraft observations to numerical simulations of SEPs' transport processes. This method can be called a simulation method. But a reasonably good fitting needs a lot of simulations, which demand a large amount of calculation resources. Sometimes, it is necessary to find an easy way to obtain the mean free path of SEPs quickly, for example, in space weather practice. Recently, Shalchi et al. provided an approximate analytical formula of SEPs' anisotropy time profile as a function of particles' mean free path for impulsive events. In this paper, we determine SEPs' mean free path by fitting the anisotropy time profiles from Shalchi et al.'s analytical formula to spacecraft observations. This new method can be called an analytical method. In addition, we obtain SEPs' mean free path with the traditional simulation methods. Finally, we compare the mean free path obtained with the simulation method to that of the analytical method to show that the analytical method, with some minor modifications, can give us a good, quick approximation of SEPs' mean free path for impulsive events.

  1. RSARF: Prediction of residue solvent accessibility from protein sequence using random forest method

    KAUST Repository

    Ganesan, Pugalenthi

    2012-01-01

    Prediction of protein structure from its amino acid sequence is still a challenging problem. The complete physicochemical understanding of protein folding is essential for the accurate structure prediction. Knowledge of residue solvent accessibility gives useful insights into protein structure prediction and function prediction. In this work, we propose a random forest method, RSARF, to predict residue accessible surface area from protein sequence information. The training and testing was performed using 120 proteins containing 22006 residues. For each residue, buried and exposed state was computed using five thresholds (0%, 5%, 10%, 25%, and 50%). The prediction accuracy for 0%, 5%, 10%, 25%, and 50% thresholds are 72.9%, 78.25%, 78.12%, 77.57% and 72.07% respectively. Further, comparison of RSARF with other methods using a benchmark dataset containing 20 proteins shows that our approach is useful for prediction of residue solvent accessibility from protein sequence without using structural information. The RSARF program, datasets and supplementary data are available at http://caps.ncbs.res.in/download/pugal/RSARF/. - See more at: http://www.eurekaselect.com/89216/article#sthash.pwVGFUjq.dpuf

  2. Analytical methods for 2,4-D (Dichlorophenoxyacetic acid) determination

    International Nuclear Information System (INIS)

    Martinez G, M.S.M.

    1999-01-01

    The 2,4-D herbicide is one of the main pesticides for controlling the bad grass in crops such as the water undergrowth. In Mexico the allowed bound of this pesticide is 0.05 mg/l in water of 2,4-D so it is required to have methods trusts and exacts, which can used in order to detected low concentration of it. In this work we show some for the conventional techniques and for establishing the 2,4-D concentrations. The UV-Vis spectrometer and liquids chromatography due that they are the most common used nowadays. Beside, we introduce a now developed technique, which is based on the neutronic activation analysis. Though use of the UV-Vis spectrometer technique it was possible target the concentrations interval between 1 and 200 mg/l. In the liquids chromatography interval was between 0.1 and 0.9, and by the neutronic activation analysis the interval was between 0.01 and 200 mg/l. (Author)

  3. Asymptotic Solutions of Time-Space Fractional Coupled Systems by Residual Power Series Method

    Directory of Open Access Journals (Sweden)

    Wenjin Li

    2017-01-01

    Full Text Available This paper focuses on the asymptotic solutions to time-space fractional coupled systems, where the fractional derivative and integral are described in the sense of Caputo derivative and Riemann-Liouville integral. We introduce the Residual Power Series (for short RPS method to construct the desired asymptotic solutions. Furthermore, we apply this method to some time-space fractional coupled systems. The simplicity and efficiency of RPS method are shown by the application.

  4. Fibonacci collocation method with a residual error Function to solve linear Volterra integro differential equations

    Directory of Open Access Journals (Sweden)

    Salih Yalcinbas

    2016-01-01

    Full Text Available In this paper, a new collocation method based on the Fibonacci polynomials is introduced to solve the high-order linear Volterra integro-differential equations under the conditions. Numerical examples are included to demonstrate the applicability and validity of the proposed method and comparisons are made with the existing results. In addition, an error estimation based on the residual functions is presented for this method. The approximate solutions are improved by using this error estimation.

  5. Electromagnetic wave theory for boundary-value problems an advanced course on analytical methods

    CERN Document Server

    Eom, Hyo J

    2004-01-01

    Electromagnetic wave theory is based on Maxwell's equations, and electromagnetic boundary-value problems must be solved to understand electromagnetic scattering, propagation, and radiation. Electromagnetic theory finds practical applications in wireless telecommunications and microwave engineering. This book is written as a text for a two-semester graduate course on electromagnetic wave theory. As such, Electromagnetic Wave Theory for Boundary-Value Problems is intended to help students enhance analytic skills by solving pertinent boundary-value problems. In particular, the techniques of Fourier transform, mode matching, and residue calculus are utilized to solve some canonical scattering and radiation problems.

  6. An introduction to clinical microeconomic analysis: purposes and analytic methods.

    Science.gov (United States)

    Weintraub, W S; Mauldin, P D; Becker, E R

    1994-06-01

    The recent concern with health care economics has fostered the development of a new discipline that is generally called clinical microeconomics. This is a discipline in which microeconomic methods are used to study the economics of specific medical therapies. It is possible to perform stand alone cost analyses, but more profound insight into the medical decision making process may be accomplished by combining cost studies with measures of outcome. This is most often accomplished with cost-effectiveness or cost-utility studies. In cost-effectiveness studies there is one measure of outcome, often death. In cost-utility studies there are multiple measures of outcome, which must be grouped together to give an overall picture of outcome or utility. There are theoretical limitations to the determination of utility that must be accepted to perform this type of analysis. A summary statement of outcome is quality adjusted life years (QALYs), which is utility time socially discounted survival. Discounting is used because people value a year of future life less than a year of present life. Costs are made up of in-hospital direct, professional, follow-up direct, and follow-up indirect costs. Direct costs are for medical services. Indirect costs reflect opportunity costs such as lost time at work. Cost estimates are often based on marginal costs, or the cost for one additional procedure of the same type. Finally an overall statistic may be generated as cost per unit increase in effectiveness, such as dollars per QALY.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Photography - Determination of thiosulphate and other residual chemicals in processed photographic films, plates and papers - Methylene blue photometric method and silver sulphide densitometric method

    CERN Document Server

    International Organization for Standardization. Geneva

    1977-01-01

    Photography - Determination of thiosulphate and other residual chemicals in processed photographic films, plates and papers - Methylene blue photometric method and silver sulphide densitometric method

  8. Validation of an efficient method for the determination of pesticide residues in fruits and vegetables using ethyl acetate for extraction.

    Science.gov (United States)

    Aysal, Perihan; Ambrus, Arpád; Lehotay, Steven J; Cannavan, Andrew

    2007-01-01

    In this study, a version of the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method was modified to use ethyl acetate (EtOAc) rather than acetonitrile (MeCN) for extraction in the determination of multiple pesticide residues in fruits and vegetables. EtOAc is better suited than MeCN for gas chromatographic (GC) analysis with electron capture detection (ECD) and nitrogen-phosphorus detection (NPD). The method entailed extraction of 30 g chopped sample plus 5 g NaHCO(3) and 30 g anhydrous Na(2)SO(4) with 60 mL EtOAc using a probe blender. After a centrifugation step, removal of residual water and cleanup were performed using dispersive solid-phase extraction (dispersive-SPE) with MgSO(4) and primary secondary amine (PSA) sorbent. (14)C-labeled chlorpyrifos with liquid scintillation counting was used to assist in optimizing and characterizing the method, and GC-ECD and GC-NPD were used for analysis of 24 selected pesticides. The method was validated using tomato, apple and frozen green bean matrices spiked at 0.05, 0.5, and 5 mg/kg. For 22 of the analytes, recoveries averaged 93% for all three commodities over the validation range with a relative standard deviation of 10% (n = 1182). Lower recoveries of dichlorvos were obtained with the method and iprodione determination was compromised in the green beans by an interfering peak. Typical limits of detection were 0.005-0.01 mg/kg with the method.

  9. Development of nondestructive hybrid measuring method for three-dimensional residual stress distribution of thick welded joint. Hybrid measuring method of inherent strain method and neutron diffraction method

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Kasahara, Norifumi; Tamura, Ryota

    2012-01-01

    The measuring methods of the residual stress are classified into destructive one and nondestructive one. The inherent strain method (ISM) is destructive one. The neutron diffraction method (NDM) is nondestructive one. But the measurable depth is limited within about 20 mm and the method cannot measure the weld zone, without destruction of the object. So, in this study, the hybrid measuring method has been developed, by combining the ISM and the NDM. The theory of the hybrid method is the same as the ISM. In the analysis, the strains measured by the NDM without destruction are used. This hybrid measuring method is a true nondestructive measuring method for a thick welded joint. The applicability of the hybrid method has been verified by simulation, using a butt welded joint of thick pipes. In the simulation, the reliable order of the strains measured by the present NDM is very important, and was considered as 10 micro. The measurable regions by the present NDM were assumed. Under the above conditions, the data (the residual elastic strains assumed to be measured by the NDM) were made, and used in the ISM. As a result of such simulation, it has been cleared that the estimated residual stress has very high accuracy, if enough data are used. The required number of data is less than the ISM. (author)

  10. Waste Tank Organic Safety Program: Analytical methods development. Progress report, FY 1994

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.A.; Grant, K.E.

    1994-09-01

    The objectives of this task are to develop and document extraction and analysis methods for organics in waste tanks, and to extend these methods to the analysis of actual core samples to support the Waste Tank organic Safety Program. This report documents progress at Pacific Northwest Laboratory (a) during FY 1994 on methods development, the analysis of waste from Tank 241-C-103 (Tank C-103) and T-111, and the transfer of documented, developed analytical methods to personnel in the Analytical Chemistry Laboratory (ACL) and 222-S laboratory. This report is intended as an annual report, not a completed work

  11. Effect of depth of planting, methods of planting and animal residues ...

    African Journals Online (AJOL)

    This study was carried out in farmers' field, from March to December in 2014 and 2015 cropping seasons at the research site of the Lower Niger River Basin Development Authority, Ejiba, Kogi State of Nigeria to investigate the effect of depth of planting, methods of planting and animal residues application on the growth and ...

  12. A method for computing the inter-residue interaction potentials for ...

    Indian Academy of Sciences (India)

    PRAKASH KUMAR

    2007-06-16

    Jun 16, 2007 ... [Luthra A, Jha A N, Ananthasuresh G K and Vishveswara S 2007 A method for computing the inter-residue interaction potentials for reduced amino acid alphabet; J. ... Therefore, a systematic approach to this problem is warranted so ... chemical and biological or quantitative measures are used. Dayhoff et al ...

  13. Nouws antibiotics test: Validation of a post-screening method for antibiotic residues in kidney

    NARCIS (Netherlands)

    Pikkemaat, M.G.; Oostra-van Dijk, S.; Schouten, J.; Rapallini, M.; Kortenhoeven, L.; Egmond, van H.J.

    2009-01-01

    Anticipating the rise in ‘suspect’ samples caused by the introduction of a more sensitive screening test for the presence of antibiotic residues in slaughter animals, an additional microbial post-screening method was developed. The test comprises four antibiotic group specific test plates, optimized

  14. Application of capability indices and control charts in the analytical method control strategy.

    Science.gov (United States)

    Oliva, Alexis; Llabres Martinez, Matías

    2017-08-01

    In this study, we assessed the usefulness of control charts in combination with the process capability indices, C pm and C pk , in the control strategy of an analytical method. The traditional X-chart and moving range chart were used to monitor the analytical method over a 2-year period. The results confirmed that the analytical method is in-control and stable. Different criteria were used to establish the specifications limits (i.e. analyst requirements) for fixed method performance (i.e. method requirements). If the specification limits and control limits are equal in breadth, the method can be considered "capable" (C pm  = 1), but it does not satisfy the minimum method capability requirements proposed by Pearn and Shu (2003). Similar results were obtained using the C pk index. The method capability was also assessed as a function of method performance for fixed analyst requirements. The results indicate that the method does not meet the requirements of the analytical target approach. A real-example data of a SEC with light-scattering detection method was used as a model whereas previously published data were used to illustrate the applicability of the proposed approach. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Analytical chemistry in semiconductor manufacturing: Techniques, role of nuclear methods and need for quality control

    International Nuclear Information System (INIS)

    1989-06-01

    This report is the result of a consultants meeting held in Gaithersburg, USA, 2-3 October 1987. The meeting was hosted by the National Bureau of Standards and Technology, and it was attended by 18 participants from Denmark, Finland, India, Japan, Norway, People's Republic of China and the USA. The purpose of the meeting was to assess the present status of analytical chemistry in semiconductor manufacturing, the role of nuclear analytical methods and the need for internationally organized quality control of the chemical analysis. The report contains the three presentations in full and a summary report of the discussions. Thus, it gives an overview of the need of analytical chemistry in manufacturing of silicon based devices, the use of nuclear analytical methods, and discusses the need for quality control. Refs, figs and tabs

  16. Ernst Equation and Riemann Surfaces: Analytical and Numerical Methods

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Frederick J [FJE Enterprises, 511 County Route 59, Potsdam, NY 13676 (United States)

    2007-06-18

    source can be represented by discontinuities in the metric tensor components. The first two chapters of this book are devoted to some basic ideas: in the introductory chapter 1 the authors discuss the concept of integrability, comparing the integrability of the vacuum Ernst equation with the integrability of nonlinear equations of Korteweg-de Vries (KdV) type, while in chapter 2 they describe various circumstances in which the vacuum Ernst equation has been determined to be relevant, not only in connection with gravitation but also, for example, in the construction of solutions of the self-dual Yang-Mills equations. It is also in this chapter that one of several equivalent linear systems for the Ernst equation is described. The next two chapters are devoted to Dmitry Korotkin's concept of algebro-geometric solutions of a linear system: in chapter 3 the structure of such solutions of the vacuum Ernst equation, which involve Riemann theta functions of hyperelliptic algebraic curves of any genus, is contrasted with the periodic structure of such solutions of the KdV equation. How such solutions can be obtained, for example, by solving a matrix Riemann-Hilbert problem and how the metric tensor of the associated spacetime can be evaluated is described in detail. In chapter 4 the asymptotic behaviour and the similarity structure of the general algebro-geometric solutions of the Ernst equation are described, and the relationship of such solutions to the perhaps more familiar multi-soliton solutions is discussed. The next three chapters are based upon the authors' own published research: in chapter 5 it is shown that a problem involving counter-rotating infinitely thin disks of matter can be solved in terms of genus two Riemann theta functions, while in chapter 6 the authors describe numerical methods that facilitate the construction of such solutions, and in chapter 7 three-dimensional graphs are displayed that depict all metrical fields of the associated spacetime

  17. Apparatus and method for rapid detection of explosives residue from the deflagration signature thereof

    Science.gov (United States)

    Funsten, H.O.; McComas, D.J.

    1999-06-15

    Apparatus and method are disclosed for rapid detection of explosives residue from the deflagration signature thereof. A property inherent to most explosives is their stickiness, resulting in a strong tendency of explosive particulate to contaminate the environment of a bulk explosive. An apparatus for collection of residue particulate, burning the collected particulate, and measurement of the ultraviolet emission produced thereby, is described. The present invention can be utilized for real-time screening of personnel, cars, packages, suspected devices, etc., and provides an inexpensive, portable, and noninvasive means for detecting explosives. 4 figs.

  18. Evaluation and selection of in-situ leaching mining method using analytic hierarchy process

    International Nuclear Information System (INIS)

    Zhao Heyong; Tan Kaixuan; Liu Huizhen

    2007-01-01

    According to the complicated conditions and main influence factors of in-situ leaching min- ing, a model and processes of analytic hierarchy are established for evaluation and selection of in-situ leaching mining methods based on analytic hierarchy process. Taking a uranium mine in Xinjiang of China for example, the application of this model is presented. The results of analyses and calculation indicate that the acid leaching is the optimum project. (authors)

  19. Application of Statistical Methods to Activation Analytical Results near the Limit of Detection

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Wanscher, B.

    1978-01-01

    Reporting actual numbers instead of upper limits for analytical results at or below the detection limit may produce reliable data when these numbers are subjected to appropriate statistical processing. Particularly in radiometric methods, such as activation analysis, where individual standard...... deviations of analytical results may be estimated, improved discrimination may be based on the Analysis of Precision. Actual experimental results from a study of the concentrations of arsenic in human skin demonstrate the power of this principle....

  20. A REVIEW: AN APPROACH TOWARDS THE ANALYTICAL METHOD DEVELOPMENT FOR DETERMINATION OF NEWER DRUGS

    OpenAIRE

    Kirtimaya Mishra*, Dr. K. Balamurugan1, Dr. R. Suresh1

    2017-01-01

    In this present scenario for treating various diseases several new drugs were invented. Before launching to the market these drugs must undergo analytical validation process. In this review some of analytical techniques such as ultraviolet/ visible spectrophotometry, fluorimetry, capillary electrophoresis, and chromatographic methods (gas chromatography and high-performance liquid chromatography), LC-MS, GC-MS, SOLID PHASE EXTRACTION, NMR, MASS Spectrophotometry LC/MS/MS LC/UV X-ray crystallo...

  1. Liquid chromatography-UV diode-array detection method for multi-residue determination of macrolide antibiotics in sheep's milk.

    Science.gov (United States)

    García-Mayor, M A; Garcinuño, R M; Fernández-Hernando, P; Durand-Alegría, J S

    2006-07-28

    A rapid, simple and sensitive liquid chromatography-UV diode-array detection method was developed for the simultaneous determination of seven macrolides (erythromycin, oleandomycin, roxithromycin, josamycin, spiramycin, tylosin and ivermectin) in sheep's milk. The column, mobile phase, temperature and flow rate were optimised to provide the best resolution of these analytes. The extraction of the antibiotic residues involves the treatment of protein-free samples with a combination of concentrated sodium hydroxide and ethyl acetate. Necessary defatting is achieved by alkaline hydrolysis. The recovery of each antibiotic was between 55% and 77%, with relative standard deviations ranging from 1% to 6.5%. The limit of quantification was 72.4 microg/kg for ivermectin, 48.3 microg/kg for roxithromycin, and 24.1 microg/kg for erythromycin, oleandomycin, spiramycin, josamycin and tylosin. The procedure was successfully used in the multi-residue determination of these macrolides at levels below the maximum concentrations legally allowed in milk samples.

  2. A multi-residue method for 17 anticoccidial drugs and ractopamine in animal tissues by liquid chromatography-tandem mass spectrometry and time-of-flight mass spectrometry.

    Science.gov (United States)

    Matus, Johanna L; Boison, Joe O

    2016-05-01

    A new and sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) and liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QToF-MS) method was developed and validated for the determination and confirmation of residues of 17 anticoccidials, plus free ractopamine in poultry muscle and liver, and bovine muscle, liver, and kidney tissues. The 17 anticoccidials are lasalocid, halofuginone, narasin, monensin, semduramicin, ethopabate, robenidine, buquinolate, toltrazuril as its sulfone metabolite, maduramicin, salinomycin, diclazuril, amprolium, decoquinate, dinitolmide, clopidol, and the nicarbazin metabolite DNC (N,N1-bis(4-nitrophenyl)urea). The analytes were extracted and cleaned up within a 3-hour period by simply extracting the analytes into a solvent mixture with salts followed by centrifugation, dilution, and filtration. The validated method was used in a pilot study for the analysis of 173 samples that included quail liver, bovine kidney, liver, muscle, and horse muscle. The predominant residues found in this study were monensin, ractopamine, and lasalocid. The results of this pilot study showed that this new method is applicable to real samples, and is fit for use in a regulatory testing programme. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd.

  3. Characteristic and principle of the residual stress measurement by neutron diffraction method

    International Nuclear Information System (INIS)

    Akiniwa, Yoshiaki

    2016-01-01

    Although X-ray method has been widely used as the nondestructive measurement method of residual stress, the object to be measured with laboratory X-ray was limited to the vicinity of surface, and the nondestructive measurement of stress inside an essential component could not be performed. Since the neutron method utilizes the wave characteristics of electrically neutral particles, the penetrability is excellent so that information up to the inside of a material can be obtained sufficiently. As the feature of neutron stress measurement, it is suitable for measurement inside metals such as iron and aluminum, which cannot be measured with X-rays. For the measurement of residual stress in localized region, the use of high energy synchrotron radiation is advantageous. In the stress measurement utilizing diffraction phenomena, there is the strain calculated from a change in diffraction lattice spacing. The measured strain is converted into stress using Hooke's Law. As the measurement examples of neutron stress evaluation, the following are introduced: (1) residual stress distribution around the ferrite steel (50 mm thick) welded joint of a large-sized structure, (2) residual stress due to the heat treatment of aluminum alloy with a plate thickness of 20 to 140 mm, and (3) change in the strain of aluminum die block in the vicinity of a cast iron cylinder liner of engine, when heating/cooling up to 470degC. (A.O.)

  4. Vest-over-Pant Method for Closure of Residual Cavity of Liver Hydatid Cyst

    Directory of Open Access Journals (Sweden)

    Saba Behdad

    2012-01-01

    Full Text Available Objective. Although several therapeutic strategies have proven to be effective for hydatid cyst of liver, but surgery is still the most common therapy despite its morbidity and mortality. Furthermore, a variety of technique has been recommended for managing the residual cavity after cystectomy. We report here a new technical method for the reconstruction of hydatid cyst residual cavity with using overlapping flaps of liver edges (Vest over Pant. Methods. In this technique after removing the cyst, the edges of one side of cyst cavity were sutured to the base of the cavity using three to four mattress sutures, and edges of other side of liver was overlapped on the dorsal part of previous layer using four to five mattress sutures. Therefore residual cavity dead space was obliterated with two surfaces of cavity. Results. Fifty males were treated by our method. The average cyst volume was 423±110 mL. There was no intraabdominal sepsis, bile leakage, or hepatic necrosis. In follow-up ultrasound study, residual cavities were disappeared one month after operation. Conclusion. Overlapping flaps of liver edges (Vest over Pant provides easy, safe closure of cyst with preservation of the liver anatomy.

  5. Selenium contaminated waters: An overview of analytical methods, treatment options and recent advances in sorption methods.

    Science.gov (United States)

    Santos, Sílvia; Ungureanu, Gabriela; Boaventura, Rui; Botelho, Cidália

    2015-07-15

    Selenium is an essential trace element for many organisms, including humans, but it is bioaccumulative and toxic at higher than homeostatic levels. Both selenium deficiency and toxicity are problems around the world. Mines, coal-fired power plants, oil refineries and agriculture are important examples of anthropogenic sources, generating contaminated waters and wastewaters. For reasons of human health and ecotoxicity, selenium concentration has to be controlled in drinking-water and in wastewater, as it is a potential pollutant of water bodies. This review article provides firstly a general overview about selenium distribution, sources, chemistry, toxicity and environmental impact. Analytical techniques used for Se determination and speciation and water and wastewater treatment options are reviewed. In particular, published works on adsorption as a treatment method for Se removal from aqueous solutions are critically analyzed. Recent published literature has given particular attention to the development and search for effective adsorbents, including low-cost alternative materials. Published works mostly consist in exploratory findings and laboratory-scale experiments. Binary metal oxides and LDHs (layered double hydroxides) have presented excellent adsorption capacities for selenium species. Unconventional sorbents (algae, agricultural wastes and other biomaterials), in raw or modified forms, have also led to very interesting results with the advantage of their availability and low-cost. Some directions to be considered in future works are also suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. MULTIPLE CRITERA METHODS WITH FOCUS ON ANALYTIC HIERARCHY PROCESS AND GROUP DECISION MAKING

    Directory of Open Access Journals (Sweden)

    Lidija Zadnik-Stirn

    2010-12-01

    Full Text Available Managing natural resources is a group multiple criteria decision making problem. In this paper the analytic hierarchy process is the chosen method for handling the natural resource problems. The one decision maker problem is discussed and, three methods: the eigenvector method, data envelopment analysis method, and logarithmic least squares method are presented for the derivation of the priority vector. Further, the group analytic hierarchy process is discussed and six methods for the aggregation of individual judgments or priorities: weighted arithmetic mean method, weighted geometric mean method, and four methods based on data envelopment analysis are compared. The case study on land use in Slovenia is applied. The conclusions review consistency, sensitivity analyses, and some future directions of research.

  7. Microextraction techniques at the analytical laboratory: an efficient way for determining low amounts of residual insecticides in soils

    Science.gov (United States)

    Viñas, Pilar; Navarro, Tania; Campillo, Natalia; Fenoll, Jose; Garrido, Isabel; Cava, Juana; Hernandez-Cordoba, Manuel

    2017-04-01

    Microextraction techniques allow sensitive measurements of pollutants to be carried out by means of instrumentation commonly available at the analytical laboratory. This communication reports our studies focused to the determination of pyrethroid insecticides in polluted soils. These chemicals are synthetic analogues of pyrethrum widely used for pest control in agricultural and household applications. Because of their properties, pyrethroids tend to strongly absorb to soil particles and organic matter. Although they are considered as pesticides with a low toxicity for humans, long times exposure to them may cause damage in immune system and in the neurological system. The procedure here studied is based on dispersive liquid-liquid microextraction (DLLME), and permits the determination of fifteen pyrethroid compounds (allethrin, resmethrin, tetramethrin, bifenthrin, fenpropathrin, cyhalothrin, acrinathrin, permethrin, λ-cyfluthrin, cypermethrin, flucythrinate, fenvalerate, esfenvalerate, τ-fluvalinate, and deltamethrin) in soil samples using gas chromatography with mass spectrometry (GC-MS). The analytes were first extracted from the soil samples (4 g) by treatment with 2 mL of acetonitrile, 2 mL of water and 0.5 g of NaCl. The enriched organic phase (approximately 0.8 mL) was separated by centrifugation, and this solution used as the dispersant in a DLLME process. The analytes did not need to be derivatized before their injection into the chromatographic system, due to their volatility and thermal stability. The identification of the different pyrethroids was carried out based on their retention times and mass spectra, considering the m/z values of the different fragments and their relative abundances. The detection limits were in the 0.2-23 ng g-1 range, depending on the analyte and the sample under analysis. The authors are grateful to the Comunidad Autonóma de la Región de Murcia, Spain (Fundación Séneca, 19888/GERM/15) and to the Spanish MINECO (Project

  8. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    International Nuclear Information System (INIS)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S.

    2013-01-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  9. Analytical method for reconstruction pin to pin of the nuclear power density distribution

    Energy Technology Data Exchange (ETDEWEB)

    Pessoa, Paulo O.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: ppessoa@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@imp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    An accurate and efficient method for reconstructing pin to pin of the nuclear power density distribution, involving the analytical solution of the diffusion equation for two-dimensional neutron energy groups in homogeneous nodes, is presented. The boundary conditions used for analytic as solution are the four currents or fluxes on the surface of the node, which are obtained by Nodal Expansion Method (known as NEM) and four fluxes at the vertices of a node calculated using the finite difference method. The analytical solution found is the homogeneous distribution of neutron flux. Detailed distributions pin to pin inside a fuel assembly are estimated by the product of homogeneous flux distribution by local heterogeneous form function. Furthermore, the form functions of flux and power are used. The results obtained with this method have a good accuracy when compared with reference values. (author)

  10. Assessment of Two Analytical Methods in Solving the Linear and Nonlinear Elastic Beam Deformation Problems

    DEFF Research Database (Denmark)

    Barari, Amin; Ganjavi, B.; Jeloudar, M. Ghanbari

    2010-01-01

    Purpose – In the last two decades with the rapid development of nonlinear science, there has appeared ever-increasing interest of scientists and engineers in the analytical techniques for nonlinear problems. This paper considers linear and nonlinear systems that are not only regarded as general...... boundary value problems, but also are used as mathematical models in viscoelastic and inelastic flows. The purpose of this paper is to present the application of the homotopy-perturbation method (HPM) and variational iteration method (VIM) to solve some boundary value problems in structural engineering...... and fluid mechanics. Design/methodology/approach – Two new but powerful analytical methods, namely, He's VIM and HPM, are introduced to solve some boundary value problems in structural engineering and fluid mechanics. Findings – Analytical solutions often fit under classical perturbation methods. However...

  11. Origin Determination and Differentiation of Gelatin Species of Bovine, Porcine, and Piscine through Analytical Methods

    Directory of Open Access Journals (Sweden)

    Hatice Saadiye Eryılmaz

    2017-06-01

    Full Text Available Gelatin origin determination has been a crucial issue with respect to religion and health concerns. It is necessary to analyze the origin of gelatin with reliable methods to ensure not only consumer choices but also safety and legal requirements such as labeling. There are many analytical methods developed for detection and/or quantification of gelatin from different sources including bovine, porcine and piscine. These analytical methods can be divided into physicochemical, chromatographic, immunochemical, spectroscopic and molecular methods. Moreover, computational methods have been used in some cases consecutively to ensure sensitivity of the analytical methods. Every method has different advantages and limitations due to their own principles, applied food matrix and process conditions of material. The present review intends to give insight into novel analytical methods and perspectives that have been developed to differentiate porcine, bovine and piscine gelatins and to establish their authenticity. Almost every method can be succeeded in origin determination; however, it is a matter of sensitivity in that some researches fail to ensure sufficient differentiation.

  12. Analytical method comparisons for the accurate determination of PCBs in sediments

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M.; Yarita, T.; Aoyagi, Y.; Yamazaki, M.; Takatsu, A. [National Metrology Institute of Japan, Tsukuba (Japan)

    2004-09-15

    National Metrology Institute of Japan in National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has been developing several matrix reference materials, for example, sediments, water and biological tissues, for the determinations of heavy metals and organometallic compounds. The matrix compositions of those certified reference materials (CRMs) are similar to compositions of actual samples, and those are useful for validating analytical procedures. ''Primary methods of measurements'' are essential to obtain accurate and SI-traceable certified values in the reference materials, because the methods have the highest quality of measurement. However, inappropriate analytical operations, such as incomplete extraction of analytes or crosscontamination during analytical procedures, will cause error of analytical results, even if one of the primary methods, isotope-dilution, is utilized. To avoid possible procedural bias for the certification of reference materials, we employ more than two analytical methods which have been optimized beforehand. Because the accurate determination of trace POPs in the environment is important to evaluate their risk, reliable CRMs are required by environmental chemists. Therefore, we have also been preparing matrix CRMs for the determination of POPs. To establish accurate analytical procedures for the certification of POPs, extraction is one of the critical steps as described above. In general, conventional extraction techniques for the determination of POPs, such as Soxhlet extraction (SOX) and saponification (SAP), have been characterized well, and introduced as official methods for environmental analysis. On the other hand, emerging techniques, such as microwave-assisted extraction (MAE), pressurized fluid extraction (PFE) and supercritical fluid extraction (SFE), give higher recovery yields of analytes with relatively short extraction time and small amount of solvent, by reasons of the high

  13. Food and Environmental Protection Laboratory, Seibersdorf: Discrimination of honey of different floral origins by a combination of various chemical parameters; Stable Isotopes Applied to Authenticating Honey; The use of analyte protectants in pesticide residue analytical work

    International Nuclear Information System (INIS)

    Zora Jandrić, Zora; Frew, Russell; Abrahim, Aiman; Maestroni, Britt; Ochoa, Victoria

    2014-01-01

    honey valued for its non-peroxide antimicrobial activity (NPA).The NPA is thought to be due to high levels of methyl glyoxal (MGO) and it is the manuka honey with high levels of MGO that fail the C4 sugar adulteration test. Work by FEPL indicates that this is partly due to the beekeeping practice of feeding sugar to bees during the winter. However, that does not explain the late season failures, or that the extent of failure increases as manuka honey ages. The MGO levels in manuka increase with age and it has been shown that high MGO is correlated with high apparent C4 sugar content. Current research in this field in FEPL is focused on modifying the AOAC method to overcome these false positives in the C4 sugar adulteration. A method has been developed for the removal of MGO prior to the purification of the protein that is measured as internal standard. It is hoped that the removal of the MGO will eliminate the interference in the isotope test. Tests are now underway to establish the optimum conditions for the removal of MGO and to show that the additional procedure does not affect the isotopic composition of the purified protein. Once those tasks are completed the work will move to the validation stage and involve other laboratories to test the procedure. The FEPL is currently carrying out a study on method validation for the detection of several pesticides in potato samples. The extraction and clean-up method used is known as the Quick, Easy, Cheap, Effective Rugged and Safe (QuEchERS) for pesticide residue determination, and uses a gas chromatograph coupled to a mass selective detector (GC-MSD) for analyte separation and detection. According to the SANCO document (SANCO/12571/2013), matrix effects should be assessed at the initial method validation stage. Therefore as part of the calibration strategies for our method both matrix-matched and solvent calibrators were prepared

  14. Validation of QuEChERS method for the determination of some pesticide residues in two apple varieties.

    Science.gov (United States)

    Tiryaki, Osman

    2016-10-02

    This study was undertaken to validate the "quick, easy, cheap, effective, rugged and safe" (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.

  15. Investigation of Unbalanced Magnetic Force in Magnetic Geared Machine Using Analytical Methods

    DEFF Research Database (Denmark)

    Zhang, Xiaoxu; Liu, Xiao; Chen, Zhe

    2016-01-01

    The electromagnetic structure of the magnetic geared machine (MGM) may induce a significant unbalanced magnetic force (UMF). However, few methods have been developed to theoretically reveal the essential reasons for this issue in the MGM. In this paper, an analytical method based on an air...

  16. Flammable gas safety program. Analytical methods development: FY 1994 progress report

    International Nuclear Information System (INIS)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Wahl, K.; Steele, R.

    1994-09-01

    This report describes the status of developing analytical methods to account for the organic components in Hanford waste tanks, with particular focus on tanks assigned to the Flammable Gas Watch List. The methods that have been developed are illustrated by their application to samples obtained from Tank 241-SY-101 (Tank 101-SY)

  17. On Approximate Analytical Solutions of Nonlinear Vibrations of Inextensible Beams using Parameter-Expansion Method

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Lund, Erik; Thomsen, Ole Thybo

    2010-01-01

    In this work, an analytical method, which is referred to as Parameter-expansion Method is used to obtain the exact solution for the problem of nonlinear vibrations of an inextensible beam. It is shown that one term in the series expansion is sufficient to obtain a highly accurate solution, which...

  18. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  19. EVALUATION OF ANALYTICAL METHODS FOR DETERMINING PESTICIDES IN BABY FOOD AND ADULT DUPLICATE-DIET SAMPLES

    Science.gov (United States)

    Determinations of pesticides in food are often complicated by the presence of fats and require multiple cleanup steps before analysis. Cost-effective analytical methods are needed for conducting large-scale exposure studies. We examined two extraction methods, supercritical flu...

  20. 2D Stabilised analytic signal method in DC pole-pole potential data ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Using analytic signal method, interpretation of pole-pole secondary electric potentials due to 2D conductive/resistive prisms is presented. The estimated parameters are the location, lateral extent or width and depth to top surface of the prism. Forward modelling is attempted by 2D-Finite. Difference method. The proposed ...

  1. Approximate Analytic and Numerical Solutions to Lane-Emden Equation via Fuzzy Modeling Method

    Directory of Open Access Journals (Sweden)

    De-Gang Wang

    2012-01-01

    Full Text Available A novel algorithm, called variable weight fuzzy marginal linearization (VWFML method, is proposed. This method can supply approximate analytic and numerical solutions to Lane-Emden equations. And it is easy to be implemented and extended for solving other nonlinear differential equations. Numerical examples are included to demonstrate the validity and applicability of the developed technique.

  2. An Analytical Investigation of Three General Methods of Calculating Chemical-Equilibrium Compositions

    Science.gov (United States)

    Zeleznik, Frank J.; Gordon, Sanford

    1960-01-01

    The Brinkley, Huff, and White methods for chemical-equilibrium calculations were modified and extended in order to permit an analytical comparison. The extended forms of these methods permit condensed species as reaction products, include temperature as a variable in the iteration, and permit arbitrary estimates for the variables. It is analytically shown that the three extended methods can be placed in a form that is independent of components. In this form the Brinkley iteration is identical computationally to the White method, while the modified Huff method differs only'slightly from these two. The convergence rates of the modified Brinkley and White methods are identical; and, further, all three methods are guaranteed to converge and will ultimately converge quadratically. It is concluded that no one of the three methods offers any significant computational advantages over the other two.

  3. Forensic chemistry: perspective of new analytical methods applied to documentoscopy, ballistic and drugs of abuse

    OpenAIRE

    Romão, Wanderson; Schwab, Nicolas V; Bueno, Maria Izabel M. S; Sparrapan, Regina; Eberlin, Marcos N; Martiny, Andrea; Sabino, Bruno D; Maldaner, Adriano O

    2011-01-01

    In this review recent methods developed and applied to solve criminal occurences related to documentoscopy, ballistic and drugs of abuse are discussed. In documentoscopy, aging of ink writings, the sequence of line crossings and counterfeiting of documents are aspects to be solved with reproducible, fast and non-destructive methods. In ballistic, the industries are currently producing ''lead-free'' or ''nontoxic'' handgun ammunitions, so new methods of gunshot residues characterization are be...

  4. System and Method for Providing a Climate Data Analytic Services Application Programming Interface Distribution Package

    Science.gov (United States)

    Schnase, John L. (Inventor); Duffy, Daniel Q. (Inventor); Tamkin, Glenn S. (Inventor)

    2016-01-01

    A system, method and computer-readable storage devices for providing a climate data analytic services application programming interface distribution package. The example system can provide various components. The system provides a climate data analytic services application programming interface library that enables software applications running on a client device to invoke the capabilities of a climate data analytic service. The system provides a command-line interface that provides a means of interacting with a climate data analytic service by issuing commands directly to the system's server interface. The system provides sample programs that call on the capabilities of the application programming interface library and can be used as templates for the construction of new client applications. The system can also provide test utilities, build utilities, service integration utilities, and documentation.

  5. Residual stress evaluation in the vicinity of ceramic coating interface using polychromatic X-ray method

    Energy Technology Data Exchange (ETDEWEB)

    Shibano, Jun-ichi; Ukai, Takayoshi; Tadano, Shigeru [Hokkaido Univ., Sapporo (Japan). Faculty of Engineering; Todoh, Masahiro

    1995-06-01

    This paper presents a polychromatic X-ray method for nondestructive evaluation of residual stress distributed in the vicinity of the interface between a ceramic coating layer and a substrate metal. Since the strain is assumed to be a linear function of the depth, the strain distribution along the depth direction can be obtained from the weighted mean strain equation calculated by considering the intensity of diffracted X-rays over the penetration depth. Therefore, the distribution along the depth direction of the residual stress was determined by the strain distributions in two directions: the vertical direction and the inclined direction to the surface. SUS316 coated with TiN by the PVD process was used as the specimen. The residual stress distributions in the coating layer and the substrate of the specimen were evaluated using this method. As a result, not only compressive residual stress in the coating layer but also the stress gradient in the substrate could be confirmed simultaneously and nondestructively. (author).

  6. Analytical method for turbine blade temperature mapping to estimate a pyrometer input signal

    OpenAIRE

    MacKay, James D.

    1987-01-01

    The purpose of this thesis is to develop a method to estimate local blade temperatures in a gas turbine for comparison with the output signal of an experimental pyrometer. The goal of the method is to provide a temperature measurement benchmark based on a knowledge of blade geometry and engine operating conditions. A survey of currently available methods is discussed including both experimental and analytical techniques.The purpose of this thesis is to develop a method to estim...

  7. Reliability residual-life prediction method for thermal aging based on performance degradation

    International Nuclear Information System (INIS)

    Ren Shuhong; Xue Fei; Yu Weiwei; Ti Wenxin; Liu Xiaotian

    2013-01-01

    The paper makes the study of the nuclear power plant main pipeline. The residual-life of the main pipeline that failed due to thermal aging has been studied by the use of performance degradation theory and Bayesian updating methods. Firstly, the thermal aging impact property degradation process of the main pipeline austenitic stainless steel has been analyzed by the accelerated thermal aging test data. Then, the thermal aging residual-life prediction model based on the impact property degradation data is built by Bayesian updating methods. Finally, these models are applied in practical situations. It is shown that the proposed methods are feasible and the prediction accuracy meets the needs of the project. Also, it provides a foundation for the scientific management of aging management of the main pipeline. (authors)

  8. A Straight-Line Method for Analyzing Residual Drawdowns at an Observation Well

    Directory of Open Access Journals (Sweden)

    Mesut Çimen

    2015-01-01

    Full Text Available Determination of the hydraulic parameters (transmissivity and storage coefficients of a confined aquifer is important for effective groundwater resources. For this purpose, the residual drawdowns have been in use to estimate the aquifer parameters by the classical Theis recovery method. The proposed method of this paper depends on a straight-line through the field data and it helps to calculate the parameters quickly without any need for long-term pumping data. It is based on the expansion series of the Theis well function by consideration of three terms, and this approach is valid for the dimensionless time factor u′=S′r2/4Tt′≤0.2. The method can be applied reliably to extensive and homogeneous confined aquifers resulting in different storage coefficients during the pumping and recovery periods S≠S′. It presents a strength methodology for the parameters decision making from the residual data in the groundwater field of civil engineering.

  9. A Table Lookup Method for Exact Analytical Solutions of Nonlinear Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Ji Juan-Juan

    2017-01-01

    Full Text Available A table lookup method for solving nonlinear fractional partial differential equations (fPDEs is proposed in this paper. Looking up the corresponding tables, we can quickly obtain the exact analytical solutions of fPDEs by using this method. To illustrate the validity of the method, we apply it to construct the exact analytical solutions of four nonlinear fPDEs, namely, the time fractional simplified MCH equation, the space-time fractional combined KdV-mKdV equation, the (2+1-dimensional time fractional Zoomeron equation, and the space-time fractional ZKBBM equation. As a result, many new types of exact analytical solutions are obtained including triangular periodic solution, hyperbolic function solution, singular solution, multiple solitary wave solution, and Jacobi elliptic function solution.

  10. Simplified Analytical Methods to Analyze Lock Gates Submitted to Ship Collisions and Earthquakes

    Directory of Open Access Journals (Sweden)

    Buldgen Loic

    2015-09-01

    Full Text Available This paper presents two simplified analytical methods to analyze lock gates submitted to two different accidental loads. The case of an impact involving a vessel is first investigated. In this situation, the resistance of the struck gate is evaluated by assuming a local and a global deforming mode. The super-element method is used in the first case, while an equivalent beam model is simultaneously introduced to capture the overall bending motion of the structure. The second accidental load considered in this paper is the seismic action, for which an analytical method is presented to evaluate the total hydrodynamic pressure applied on a lock gate during an earthquake, due account being taken of the fluid-structure interaction. For each of these two actions, numerical validations are presented and the analytical results are compared to finite-element solutions.

  11. Development of CAD implementing the algorithm of boundary elements’ numerical analytical method

    Directory of Open Access Journals (Sweden)

    Yulia V. Korniyenko

    2015-03-01

    Full Text Available Up to recent days the algorithms for numerical-analytical boundary elements method had been implemented with programs written in MATLAB environment language. Each program had a local character, i.e. used to solve a particular problem: calculation of beam, frame, arch, etc. Constructing matrices in these programs was carried out “manually” therefore being time-consuming. The research was purposed onto a reasoned choice of programming language for new CAD development, allows to implement algorithm of numerical analytical boundary elements method and to create visualization tools for initial objects and calculation results. Research conducted shows that among wide variety of programming languages the most efficient one for CAD development, employing the numerical analytical boundary elements method algorithm, is the Java language. This language provides tools not only for development of calculating CAD part, but also to build the graphic interface for geometrical models construction and calculated results interpretation.

  12. Bithionol residue analysis in animal-derived food products by an effective and rugged extraction method coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Weijia; Park, Jin-A; Abd El-Aty, A M; Kim, Seong-Kwan; Cho, Sang-Hyun; Choi, Jeong-Min; Yi, Hee; Cho, Soo-Min; El-Banna, H A; Shim, Jae-Han; Chang, Byung-Joon; Wang, Jing; Kim, Jin-Suk; Shin, Ho-Chul

    2017-10-01

    Herein, we developed a simple analytical procedure for the quantitation of bithionol residues in animal-derived food products such as porcine muscle, eggs, milk, eel, flatfish, and shrimp using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction method coupled with liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI + /MS-MS). Samples were extracted with 0.1% solution of formic acid in acetonitrile and the extract was purified using a C18 sorbent. Separation was performed on a Waters XBridge™ C18 reversed-phase analytical column using 0.1% solution of formic acid/acetonitrile as the mobile phase. Six-point matrix-matched calibration indicated good linearity, with the calculated coefficients of determination (R 2 ) being≥0.9813. Intra- and inter-day recoveries (determined at spiking levels equivalent to 1×and 2×the limit of quantitation (0.25μg/kg)) ranged between 80.0 and 94.0%, with the corresponding relative standard deviations (RSDs) being≤8.2%. The developed experimental protocol was applied to different samples purchased from local markets in Seoul, which were tested negative for bithionol residues. In conclusion, the proposed method proved to be versatile and precise, being ideally suited for the routine detection of bithionol residues in animal-derived food products with various protein and fat contents. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Possibilities of Utilizing the Method of Analytical Hierarchy Process Within the Strategy of Corporate Social Business

    Science.gov (United States)

    Drieniková, Katarína; Hrdinová, Gabriela; Naňo, Tomáš; Sakál, Peter

    2010-01-01

    The paper deals with the analysis of the theory of corporate social responsibility, risk management and the exact method of analytic hierarchic process that is used in the decision-making processes. The Chapters 2 and 3 focus on presentation of the experience with the application of the method in formulating the stakeholders' strategic goals within the Corporate Social Responsibility (CSR) and simultaneously its utilization in minimizing the environmental risks. The major benefit of this paper is the application of Analytical Hierarchy Process (AHP).

  14. Progress in analytical methods for the detection of geographical origin and authenticity of tea (Camellia sinensis)

    International Nuclear Information System (INIS)

    Yuan Yuwei; Hu Guixian; Shao Shengzhi; Zhang Yongzhi; Zhang Yu; Zhu Jiahong; Yang Guiling; Zhang Zhiheng

    2013-01-01

    Tea (Camellia sinensis) is one of the important agricultural products with obvious regional characteristics. Analytical methods are very important for the protection of geographical origin and authenticity of tea. The developments of analytical methods including stable isotope determination, multi-elements determination, near infrared reflectance spectroscopy, chemical fingerprint and others were reviewed. Major problems on tea origin and authenticity detection were discussed in this study, and some suggestions were also proposed which would be useful for the protection of geographical origin of tea in China. (authors)

  15. Study of Injection Molding Warpage Using Analytic Hierarchy Process and Taguchi Method

    Directory of Open Access Journals (Sweden)

    Dyi-Cheng Chen

    2016-10-01

    Full Text Available This study integrated Analytic Hierarchy Process and Taguchi method to investigate into injection molding warpage. The warpage important factor will be elected by Analytic Hierarchy Process (AHP, the AHP hierarchy analysis factor from documents collected and aggregate out data, then through the expert questionnaire delete low weight factor. Finally, we used Taguchi quality engineering method to decide injection molding optimized combination factors. Furthermore, the paper used injection pressure, holding pressure, holding time, mold temperature to analyze four factors, three levels Taguchi design data. Moreover, the paper discussed the reaction of each factor on the S / N ratio and analysis of variance to obtain the best combination of minimal warpage.

  16. Experimental and analytical studies on the passive residual heat removal system for the advanced integral type reactor

    International Nuclear Information System (INIS)

    Park, Hyun-Sik; Choi, Ki-Yong; Cho, Seok; Park, Choon-Kyung; Lee, Sung-Jae; Song, Chul-Hwa; Chung, Moon-Ki

    2004-01-01

    An experiment on the thermal-hydraulic characteristics of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART-P, has been performed, and its experimental results have been analyzed using a best-estimated system analysis code, MARS. The experiment is performed to investigate the performance of the passive residual heat removal system using the high temperature and high pressure thermal-hydraulic test facility (VISTA) which simulates the SMART-P. The natural circulation performance of the PRHRS, the heat transfer characteristics of the PRHRS heat exchangers and the emergency cooldown tank (ECT), and the thermal-hydraulic behavior of the primary loop are investigated. The experimental results show that the coolant flows steadily in the PRHRS loop and the heat transfer through the PRHRS heat exchanger in the emergency cooldown tank is sufficient enough to enable a natural circulation of the coolant. Analysis on a typical PRHRS test has been carried out using the MARS code. The overall trends of the calculated flow rate, pressure, temperature, and heat transfer rate in the PRHRS are similar to the experimental data. There is good agreement between the experimental data and the calculated one for the fluid temperature in the PRHRS steam line. However, the calculated fluid temperature in the PRHRS condensate line is higher, the calculated coolant outlet temperature is lower, and the heat transfer rate through the PRHRS heat exchanger is lower than the experimental data. It seems that it is due to an insufficient heat transfer modeling in the pool such as the emergency cooldown tank in the MARS calculation. (author)

  17. An analytical-numerical comprehensive method for optimizing the fringing magnetic field

    International Nuclear Information System (INIS)

    Xiao Meiqin; Mao Naifeng

    1991-01-01

    The criterion of optimizing the fringing magnetic field is discussed, and an analytical-numerical comprehensive method for realizing the optimization is introduced. The method mentioned above consists of two parts, the analytical part calculates the field of the shims, which corrects the fringing magnetic field by using uniform magnetizing method; the numerical part fulfils the whole calculation of the field distribution by solving the equation of magnetic vector potential A within the region covered by arbitrary triangular meshes with the aid of finite difference method and successive over relaxation method. On the basis of the method, the optimization of the fringing magnetic field for a large-scale electromagnetic isotope separator is finished

  18. Research on the simultaneous multi-components analytical method for polluted soil

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kang Sup; Song, Duk Young; Choi, Byung In; Kim, Kun Han; Eum, Chul Hun; Jeon, Chi Wan; Lee, Jung Hwa [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Dissolution properties for the several inorganic pollutants in soils have been studied and simultaneous multi-components analytical method has been established with using ICP/MS for 13 monitoring elements in order to protect water and soil environments. And addition, more effective new analytical methods have been studied for TPH(total petroleum hydrocarbon) and organophosphorus compounds in soils. Several inorganic pollutants were spiked to 3 kinds of fresh soils which were sand, clay, loam. The dissolution properties of the prepared samples were investigated under the various extracting conditions such as extracting time, acid concentration, particle size, etc. in order to take basic information about the process of extraction test and improvement of related analytical methods. As the results, dissolution properties were affected mainly by acid concentration in extraction procedure and mineral composition of soils. On the other hand, extracting time, sort of acids and particle size of soils has a little influence on the dissolution properties. Cd revealed very high dissolving efficiency and As was very low in whole extracting test. Current analytical methods for the determination of soils are based on the purge and trap for volatiles such as gasoline and solvent extraction for semivolatiles such as kerosene and diesel oils. These methods are not proper in cost and time. In addition to, there are potential for analyte contamination and some problems in pretreatment procedure. In this study , we have discussed simultaneous determination of TPH containing gasoline, kerosene, diesel oils and etc. And determination of Organophosphorus compounds in soils has studied. In this procedure, the application of ultrasonication methods and several extraction methods were compared. In the results of this study, we could take very low practical detection limit and good precision. Approved methods were suitable for the determination of oils and pesticides in soil at high and low

  19. Prediction method of seismic residual deformation of caisson quay wall in liquefied foundation

    Science.gov (United States)

    Wang, Li-Yan; Liu, Han-Long; Jiang, Peng-Ming; Chen, Xiang-Xiang

    2011-03-01

    The multi-spring shear mechanism plastic model in this paper is defined in strain space to simulate pore pressure generation and development in sands under cyclic loading and undrained conditions, and the rotation of principal stresses can also be simulated by the model with cyclic behavior of anisotropic consolidated sands. Seismic residual deformations of typical caisson quay walls under different engineering situations are analyzed in detail by the plastic model, and then an index of liquefaction extent is applied to describe the regularity of seismic residual deformation of caisson quay wall top under different engineering situations. Some correlated prediction formulas are derived from the results of regression analysis between seismic residual deformation of quay wall top and extent of liquefaction in the relative safety backfill sand site. Finally, the rationality and the reliability of the prediction methods are validated by test results of a 120 g-centrifuge shaking table, and the comparisons show that some reliable seismic residual deformation of caisson quay can be predicted by appropriate prediction formulas and appropriate index of liquefaction extent.

  20. Analysis of macro and micro residual stresses in functionally graded materials by diffraction methods

    CERN Document Server

    Dantz, D; Reimers, W

    1999-01-01

    The residual stress state in microwave sintered metal-ceramic functionally graded materials (FGM) consisting of 8Y-ZrO/sub 2//Ni and 8Y-ZrO/sub 2//NiCr8020, respectively, was analysed by non- destructive diffraction methods. In $9 order to get knowledge of the complete residual stress state in the near surface region as well as in the interior of the material, complementary methods were applied. Whereas the surface was characterised by X-ray techniques using $9 conventional sources, the stresses within the bulk of the material were investigated by means of high energy synchrotron radiation. The stress state was found to obey the differences in the coefficients of thermal expansion $9 (micro-stresses) on the one hand and the inhomogeneous cooling conditions (macrostresses) on the other hand. (7 refs).

  1. Methods to Reduce Forest Residue Volume after Timber Harvesting and Produce Black Carbon

    Directory of Open Access Journals (Sweden)

    Deborah S. Page-Dumroese

    2017-01-01

    Full Text Available Forest restoration often includes thinning to reduce tree density and improve ecosystem processes and function while also reducing the risk of wildfire or insect and disease outbreaks. However, one drawback of these restoration treatments is that slash is often burned in piles that may damage the soil and require further restoration activities. Pile burning is currently used on many forest sites as the preferred method for residue disposal because piles can be burned at various times of the year and are usually more controlled than broadcast burns. In many cases, fire can be beneficial to site conditions and soil properties, but slash piles, with a large concentration of wood, needles, forest floor, and sometimes mineral soil, can cause long-term damage. We describe several alternative methods for reducing nonmerchantable forest residues that will help remove excess woody biomass, minimize detrimental soil impacts, and create charcoal for improving soil organic matter and carbon sequestration.

  2. Analytical recovery of protozoan enumeration methods: have drinking water QMRA models corrected or created bias?

    Science.gov (United States)

    Schmidt, P J; Emelko, M B; Thompson, M E

    2013-05-01

    Quantitative microbial risk assessment (QMRA) is a tool to evaluate the potential implications of pathogens in a water supply or other media and is of increasing interest to regulators. In the case of potentially pathogenic protozoa (e.g. Cryptosporidium oocysts and Giardia cysts), it is well known that the methods used to enumerate (oo)cysts in samples of water and other media can have low and highly variable analytical recovery. In these applications, QMRA has evolved from ignoring analytical recovery to addressing it in point-estimates of risk, and then to addressing variation of analytical recovery in Monte Carlo risk assessments. Often, variation of analytical recovery is addressed in exposure assessment by dividing concentration values that were obtained without consideration of analytical recovery by random beta-distributed recovery values. A simple mathematical proof is provided to demonstrate that this conventional approach to address non-constant analytical recovery in drinking water QMRA will lead to overestimation of mean pathogen concentrations. The bias, which can exceed an order of magnitude, is greatest when low analytical recovery values are common. A simulated dataset is analyzed using a diverse set of approaches to obtain distributions representing temporal variation in the oocyst concentration, and mean annual risk is then computed from each concentration distribution using a simple risk model. This illustrative example demonstrates that the bias associated with mishandling non-constant analytical recovery and non-detect samples can cause drinking water systems to be erroneously classified as surpassing risk thresholds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Comparative analysis of methods for real-time analytical control of chemotherapies preparations.

    Science.gov (United States)

    Bazin, Christophe; Cassard, Bruno; Caudron, Eric; Prognon, Patrice; Havard, Laurent

    2015-10-15

    Control of chemotherapies preparations are now an obligation in France, though analytical control is compulsory. Several methods are available and none of them is presumed as ideal. We wanted to compare them so as to determine which one could be the best choice. We compared non analytical (visual and video-assisted, gravimetric) and analytical (HPLC/FIA, UV/FT-IR, UV/Raman, Raman) methods thanks to our experience and a SWOT analysis. The results of the analysis show great differences between the techniques, but as expected none us them is without defects. However they can probably be used in synergy. Overall for the pharmacist willing to get involved, the implementation of the control for chemotherapies preparations must be widely anticipated, with the listing of every parameter, and remains according to us an analyst's job. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Experimental design and multiple response optimization. Using the desirability function in analytical methods development.

    Science.gov (United States)

    Candioti, Luciana Vera; De Zan, María M; Cámara, María S; Goicoechea, Héctor C

    2014-06-01

    A review about the application of response surface methodology (RSM) when several responses have to be simultaneously optimized in the field of analytical methods development is presented. Several critical issues like response transformation, multiple response optimization and modeling with least squares and artificial neural networks are discussed. Most recent analytical applications are presented in the context of analytLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, ArgentinaLaboratorio de Control de Calidad de Medicamentos (LCCM), Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, C.C. 242, S3000ZAA Santa Fe, Argentinaical methods development, especially in multiple response optimization procedures using the desirability function. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Analytical methods used at IPR (Instituto de Pesquisas Radioativas - Minas Gerais, Brazil)

    International Nuclear Information System (INIS)

    Murta, C.C.

    The analytical methods available at IPR (MG-Brazil) for the routine determination of uranium are described. These methods are: gravimetric analysis; fluorescence spectroscopy, voltametry, polarography, absorption spectroscopy, beta-and gamma-radiometric analysis, gamma spectroscopy, activation analysis, X-rays fluorescence analysis and delayed neutron analysis. Some additional methods for the study of mineral ores, such as X-rays diffractometry, emmission spectroscopy, thermal analysis, etc, are also discussed [pt

  6. Shifted Legendre method with residual error estimation for delay linear Fredholm integro-differential equations

    Directory of Open Access Journals (Sweden)

    Şuayip Yüzbaşı

    2017-03-01

    Full Text Available In this paper, we suggest a matrix method for obtaining the approximate solutions of the delay linear Fredholm integro-differential equations with constant coefficients using the shifted Legendre polynomials. The problem is considered with mixed conditions. Using the required matrix operations, the delay linear Fredholm integro-differential equation is transformed into a matrix equation. Additionally, error analysis for the method is presented using the residual function. Illustrative examples are given to demonstrate the efficiency of the method. The results obtained in this study are compared with the known results.

  7. RANDOM FUNCTIONS AND INTERVAL METHOD FOR PREDICTING THE RESIDUAL RESOURCE OF BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    Shmelev Gennadiy Dmitrievich

    2017-11-01

    Full Text Available Subject: possibility of using random functions and interval prediction method for estimating the residual life of building structures in the currently used buildings. Research objectives: coordination of ranges of values to develop predictions and random functions that characterize the processes being predicted. Materials and methods: when performing this research, the method of random functions and the method of interval prediction were used. Results: in the course of this work, the basic properties of random functions, including the properties of families of random functions, are studied. The coordination of time-varying impacts and loads on building structures is considered from the viewpoint of their influence on structures and representation of the structures’ behavior in the form of random functions. Several models of random functions are proposed for predicting individual parameters of structures. For each of the proposed models, its scope of application is defined. The article notes that the considered approach of forecasting has been used many times at various sites. In addition, the available results allowed the authors to develop a methodology for assessing the technical condition and residual life of building structures for the currently used facilities. Conclusions: we studied the possibility of using random functions and processes for the purposes of forecasting the residual service lives of structures in buildings and engineering constructions. We considered the possibility of using an interval forecasting approach to estimate changes in defining parameters of building structures and their technical condition. A comprehensive technique for forecasting the residual life of building structures using the interval approach is proposed.

  8. Analytical method used for intermediate products in continuous distillation of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z.L.; Jia, M.; Wang, L.J.; Deng, Y.X.

    1981-01-01

    During distillation of furfural, analysis of main components in the crude furfural condensate and intermediate products is very important. Since furfural and methylfurfural are homologous and both furfural and acetone contain a carbonyl group, components in the sample must be separated before analysis. An improved analytical method has been studied, the accuracy and precision of which would meet the requirement of industrial standards. The analytical procedure was provided as follows: to determine the furfural content with gravimetric method of barbituric acid; to determine the methanol content with dichromate method after precipitating furfural and acetone, and distilling the liquid for analysis; and to determine the methylfurfural content with bromide-bromate method, which can be used only in the sample containing higher content of methylfurfural. For the sample in low content, the gas-liquid chromatographic method can be used. 7 references.

  9. Solution of the isotopic depletion equation using decomposition method and analytical solution

    Energy Technology Data Exchange (ETDEWEB)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S., E-mail: fprata@con.ufrj.br, E-mail: fernando@con.ufrj.br, E-mail: aquilino@lmp.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  10. Solution of the isotopic depletion equation using decomposition method and analytical solution

    International Nuclear Information System (INIS)

    Prata, Fabiano S.; Silva, Fernando C.; Martinez, Aquilino S.

    2011-01-01

    In this paper an analytical calculation of the isotopic depletion equations is proposed, featuring a chain of major isotopes found in a typical PWR reactor. Part of this chain allows feedback reactions of (n,2n) type. The method is based on decoupling the equations describing feedback from the rest of the chain by using the decomposition method, with analytical solutions for the other isotopes present in the chain. The method was implemented in a PWR reactor simulation code, that makes use of the nodal expansion method (NEM) to solve the neutron diffusion equation, describing the spatial distribution of neutron flux inside the reactor core. Because isotopic depletion calculation module is the most computationally intensive process within simulation systems of nuclear reactor core, it is justified to look for a method that is both efficient and fast, with the objective of evaluating a larger number of core configurations in a short amount of time. (author)

  11. Validation of methods used in the Florida Department of Agricultural and Consumer Services' Chemical Residue Laboratory.

    Science.gov (United States)

    Parker, G A

    1991-01-01

    Very few methods for detecting residues of pesticides in food or agricultural samples have undergone rigorous colloborative study and possess official AOAC status. The Chemical Residue Laboratory has formalized a method validation scheme to use when incorporating or developing new, unofficial methods. These methods are validated by assessing certain performance parameters: scope, specificity, linear range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). For accuracy and precision assessment, 12 replicate fortifications must yield recoveries within the range of 70-120% with a coefficient of variation (CV) that compares favorably to the Horwitz CV. LOD and LOQ are equivalent to 3 and 10 times, respectively, the background signal contributed by a sample matrix blank. This criterion that we use for LOD/LOQ is not universal. In fact, because of differing definitions, we have encountered difficulties in enforcing a tolerance by using a registrant's method. This paper also presents an example of our method validation scheme, using a recent method development project for detecting sulfamethazine in raw milk. The sulfamethazine project also revealed unanticipated personnel problems, underscoring the importance of the human factor in quality assurance.

  12. [Comparison of pretreatment methods for the simultaneous determination of diclazuril and toltrazuril residues in chicken tissues].

    Science.gov (United States)

    Shi, Zuhao; Ge, Qinglian; Lu, Junxian; Liu, Xuexian; Gong, Jiansen; Zhu, Liangqiang; Qi, Kezong; Chen, Dingding; Peng, Kaisong

    2009-05-01

    The effects of four pretreatment methods (acetonitrile extraction-evaporation concentration, acetonitrile extraction-solid phase extraction (SPE), matrix solid-phase dispersion (MSPD) extraction and MSPD-SPE) for the simultaneous analysis of diclazuril and toltrazuril residues in chicken tissues were compared. The average recovery of 70% for the former three methods as achieved. In comparison with other methods, the MSPD method saved more than 60% in time and solvent. So, MSPD as the sample pretreatment method, an MSPD-high performance liquid chromatography with ultraviolet detection (MSPD-HPLC/UV) method was established for the analysis. Under the optimal chromatographic conditions, the linear range was between 50 and 1,000 microg/kg. At the added levels of 50, 500, 1,000 ng/g, the recoveries of diclazuril and toltrazuril in chicken tissues ranged from 71.13% - 84.02% with the relative standard deviations (RSD) in the range of 3.76% - 12.11%, and the RSDs of intra- and interday analyses ranged from 3.70% - 6.77%. The detection limits of diclazuril and toltrazuril were less than 10 microg/kg. The quantitative limits of diclazuril and toltrazuril were less than 20 microg/kg. The method meet the requirements of the residue analysis on accuracy and precision.

  13. Materials of the Second Sumy-Cracow-Muenster Symposium on Nuclear Analytical Methods

    International Nuclear Information System (INIS)

    2001-01-01

    The applications of nuclear analytical methods in physico-chemical, biological and medical studies have been presented in large number of applications. Environmental, geological and biological materials have been analysed by means of neutron activation analysis, proton microprobe, x-ray diffraction, synchrotron radiation X-ray spectrum analysis, ESR and others

  14. Analytical methods for an elliptic singular perturbation problem In a circle

    NARCIS (Netherlands)

    N.M. Temme (Nico)

    2007-01-01

    textabstractWe consider an elliptic perturbation problem in a circle by using the analytical solution that is given by a Fourier series with coefficients in terms of modified Bessel functions. By using saddle point methods we construct asymptotic approximations with respect to a small parameter.

  15. New neutron-based isotopic analytical methods; An explorative study of resonance capture and incoherent scattering

    NARCIS (Netherlands)

    Perego, R.C.

    2004-01-01

    Two novel neutron-based analytical techniques have been treated in this thesis, Neutron Resonance Capture Analysis (NRCA), employing a pulsed neutron source, and Neutron Incoherent Scattering (NIS), making use of a cold neutron source. With the NRCA method isotopes are identified by the

  16. Semi-Analytical Weight Estimation Method for Fuselages with Oval Cross-Section

    NARCIS (Netherlands)

    Vos, R.; Hoogreef, M.F.M.

    2013-01-01

    This paper presents a semi-analytical method for the weight estimation of fuselages with an oval cross-section, applied to blended wing body aircraft. The weight estimation of the fuselage primary structure is based on a structural analysis of two-dimensional crosssections and it is completed by a

  17. A semi-analytical method for simulating matrix diffusion in numerical transport models.

    Science.gov (United States)

    Falta, Ronald W; Wang, Wenwen

    2017-02-01

    A semi-analytical approximation for transient matrix diffusion is developed for use in numerical contaminant transport simulators. This method is an adaptation and extension of the heat conduction method of Vinsome and Westerveld (1980) used to simulate heat losses during thermally enhanced oil recovery. The semi-analytical method is used in place of discretization of the low permeability materials, and it represents the concentration profile in the low permeability materials with a fitting function that is adjusted in each element at each time-step. The resulting matrix diffusion fluxes are added to the numerical model as linear concentration-dependent source/sink terms. Since only the high permeability zones need to be discretized, the numerical formulation is extremely efficient compared to traditional approaches that require discretization of both the high and low permeability zones. The semi-analytical method compares favorably with the analytical solution for transient one-dimensional diffusion with first order decay, with a two-layer aquifer/aquitard solution, with the solution for transport in a fracture with matrix diffusion and decay, and with a fully numerical solution for transport in a thin sand zone bounded by clay with variable decay rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analytical Method to Calculate the DC Link Current Stress in Voltage Source Converters

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2014-01-01

    for the applications with high line current ripple. The effect of the pulsewidth modulation (PWM) scheme on the rms value of the dc-link current is also studied and the analysis for continuous PWM and discontinuous PWM (DPWM) schemes is presented. The proposed analytical method is also verified experimentally....

  19. Nuclear analytical methods in teaching and research at the university of Illinois

    International Nuclear Information System (INIS)

    Landsberger, S.

    1994-01-01

    An overview of the nuclear analytical methods opportunities at the University of Illinois at Urbana-Champaign are given. Undergraduate and graduate level teaching and research are highlighted. The TRIGA reactor and neutron activation analysis facilities are described in the context of this role within an inter-disciplinary environment. (author)

  20. Knowledge, Skills, and Abilities for Entry-Level Business Analytics Positions: A Multi-Method Study

    Science.gov (United States)

    Cegielski, Casey G.; Jones-Farmer, L. Allison

    2016-01-01

    It is impossible to deny the significant impact from the emergence of big data and business analytics on the fields of Information Technology, Quantitative Methods, and the Decision Sciences. Both industry and academia seek to hire talent in these areas with the hope of developing organizational competencies. This article describes a multi-method…

  1. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    International Nuclear Information System (INIS)

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-01-01

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S and GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S and GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more

  2. Vertical equilibrium with sub-scale analytical methods for geological CO2 sequestration

    KAUST Repository

    Gasda, S. E.

    2009-04-23

    Large-scale implementation of geological CO2 sequestration requires quantification of risk and leakage potential. One potentially important leakage pathway for the injected CO2 involves existing oil and gas wells. Wells are particularly important in North America, where more than a century of drilling has created millions of oil and gas wells. Models of CO 2 injection and leakage will involve large uncertainties in parameters associated with wells, and therefore a probabilistic framework is required. These models must be able to capture both the large-scale CO 2 plume associated with the injection and the small-scale leakage problem associated with localized flow along wells. Within a typical simulation domain, many hundreds of wells may exist. One effective modeling strategy combines both numerical and analytical models with a specific set of simplifying assumptions to produce an efficient numerical-analytical hybrid model. The model solves a set of governing equations derived by vertical averaging with assumptions of a macroscopic sharp interface and vertical equilibrium. These equations are solved numerically on a relatively coarse grid, with an analytical model embedded to solve for wellbore flow occurring at the sub-gridblock scale. This vertical equilibrium with sub-scale analytical method (VESA) combines the flexibility of a numerical method, allowing for heterogeneous and geologically complex systems, with the efficiency and accuracy of an analytical method, thereby eliminating expensive grid refinement for sub-scale features. Through a series of benchmark problems, we show that VESA compares well with traditional numerical simulations and to a semi-analytical model which applies to appropriately simple systems. We believe that the VESA model provides the necessary accuracy and efficiency for applications of risk analysis in many CO2 sequestration problems. © 2009 Springer Science+Business Media B.V.

  3. Preservatives and neutralizing substances in milk: analytical sensitivity of official specific and nonspecific tests, microbial inhibition effect, and residue persistence in milk

    Directory of Open Access Journals (Sweden)

    Livia Cavaletti Corrêa da Silva

    2015-09-01

    Full Text Available Milk fraud has been a recurring problem in Brazil; thus, it is important to know the effect of most frequently used preservatives and neutralizing substances as well as the detection capability of official tests. The objective of this study was to evaluate the analytical sensitivity of legislation-described tests and nonspecific microbial inhibition tests, and to investigate the effect of such substances on microbial growth inhibition and the persistence of detectable residues after 24/48h of refrigeration. Batches of raw milk, free from any contaminant, were divided into aliquots and mixed with different concentrations of formaldehyde, hydrogen peroxide, sodium hypochlorite, chlorine, chlorinated alkaline detergent, or sodium hydroxide. The analytical sensitivity of the official tests was 0.005%, 0.003%, and 0.013% for formaldehyde, hydrogen peroxide, and hypochlorite, respectively. Chlorine and chlorinated alkaline detergent were not detected by regulatory tests. In the tests for neutralizing substances, sodium hydroxide could not be detected when acidity was accurately neutralized. The yogurt culture test gave results similar to those obtained by official tests for the detection of specific substances. Concentrations of 0.05% of formaldehyde, 0.003% of hydrogen peroxide and 0.013% of sodium hypochlorite significantly reduced (P

  4. Design and analytic validation of BCR-ABL1 quantitative reverse transcription polymerase chain reaction assay for monitoring minimal residual disease.

    Science.gov (United States)

    Jennings, Lawrence J; Smith, Frederick A; Halling, Kevin C; Persons, Diane L; Kamel-Reid, Suzanne

    2012-01-01

    Monitoring minimal residual disease by quantitative reverse transcription polymerase chain reaction has proven clinically useful, but as yet there are no Food and Drug Administration-approved tests. Guidelines have been published that provide important information on validation of such tests; however, no practical examples have previously been published. To provide an example of the design and validation of a quantitative reverse transcription polymerase chain reaction test. To describe the approach used by an individual laboratory for development and validation of a laboratory-developed quantitative reverse transcription polymerase chain reaction test for BCR-ABL1 fusion transcripts. Elements of design and analytic validation of a laboratory-developed quantitative molecular test are discussed using quantitative detection of BCR-ABL1 fusion transcripts as an example. Validation of laboratory-developed quantitative molecular tests requires careful planning and execution to adequately address all required analytic performance parameters. How these are addressed depends on the potential for technical errors and confidence required for a given test result. We demonstrate how one laboratory validated and clinically implemented a quantitative BCR-ABL1 assay that can be used for the management of patients with chronic myelogenous leukemia.

  5. An Analytical Method for the Abel Inversion of Asymmetrical Gaussian Profiles

    International Nuclear Information System (INIS)

    Xu Guosheng; Wan Baonian

    2007-01-01

    An analytical algorithm for fast calculation of the Abel inversion for density profile measurement in tokamak is developed. Based upon the assumptions that the particle source is negligibly small in the plasma core region, density profiles can be approximated by an asymmetrical Gaussian distribution controlled only by one parameter V 0 /D and V 0 /D is constant along the radial direction, the analytical algorithm is presented and examined against a testing profile. The validity is confirmed by benchmark with the standard Abel inversion method and the theoretical profile. The scope of application as well as the error analysis is also discussed in detail

  6. The riddle of Siegfried: exploring methods and psychological perspectives in analytical psychology.

    Science.gov (United States)

    Barreto, Marco Heleno

    2016-02-01

    Jung's dream of the killing of Siegfried poses a riddle: why did the unconscious choose precisely Siegfried as the hero to be murdered? Jung himself declares that he does not know. This paper attempts to decipher this riddle using three distinct methodological approaches accepted by Jung, two of them in fact grounded in his theories of dream interpretation. Besides presenting some possible answers to the riddle of Siegfried, this interpretative reflection brings to light the discrepancy of the psychological perspectives created by the heterogeneity of methods within analytical psychology. © 2016, The Society of Analytical Psychology.

  7. Comparison of potential method in analytic hierarchy process for multi-attribute of catering service companies

    Science.gov (United States)

    Mamat, Siti Salwana; Ahmad, Tahir; Awang, Siti Rahmah

    2017-08-01

    Analytic Hierarchy Process (AHP) is a method used in structuring, measuring and synthesizing criteria, in particular ranking of multiple criteria in decision making problems. On the other hand, Potential Method is a ranking procedure in which utilizes preference graph ς (V, A). Two nodes are adjacent if they are compared in a pairwise comparison whereby the assigned arc is oriented towards the more preferred node. In this paper Potential Method is used to solve problem on a catering service selection. The comparison of result by using Potential method is made with Extent Analysis. The Potential Method is found to produce the same rank as Extent Analysis in AHP.

  8. Three higher order analytical nodal methods for multigroup neutron diffusion equations

    International Nuclear Information System (INIS)

    Guessous, Najib

    2016-01-01

    Highlights: • The highlight is to demonstrate efficiency of the three nodal methods developed in this work: PCANM-2, FANM-2 and RFANM-2. • It is proved that the third method is more competitive than the two others methods. • It is demonstrated that RFANM-2 can give very accurate results compared to others nodal methods from published works. - Abstract: This work presents three efficient higher order analytical nodal methods for the numerical solution of a two-dimensional multigroup neutron diffusion equation in Cartesian geometry based on the use of the successive polynomial-weighted transverse integrations technique to convert a one-group diffusion equation to a system of coupled one-dimensional ordinary differential equations. These equations are then solved analytically over each homogenized cell after adequate approximations of the resulting effective sources after transversal integrations. Coupling between the approximate transverse flux-moments is achieved by imposing uniqueness constraint on their moments values. Adjacent elements are coupled by enforcing continuity conditions on the flux and current moments at interfaces cells. The weighted cell-balance equations and current-continuity conditions are then used to derive the discrete equations. These methods are applied for solving numerically various 2D benchmark problems and theirs performances discussed. Numerical results demonstrates more efficiency for the third higher order analytical nodal method for which the alone unknowns considered are the transverse flux moments on the interfaces of the homogenized elements.

  9. Analytical synthetic methods of solution of neutron transport equation with diffusion theory approaches energy multigroup

    International Nuclear Information System (INIS)

    Moraes, Pedro Gabriel B.; Leite, Michel C.A.; Barros, Ricardo C.

    2013-01-01

    In this work we developed a software to model and generate results in tables and graphs of one-dimensional neutron transport problems in multi-group formulation of energy. The numerical method we use to solve the problem of neutron diffusion is analytic, thus eliminating the truncation errors that appear in classical numerical methods, e.g., the method of finite differences. This numerical analytical method increases the computational efficiency, since they are not refined spatial discretization necessary because for any spatial discretization grids used, the numerical result generated for the same point of the domain remains unchanged unless the rounding errors of computational finite arithmetic. We chose to develop a computational application in MatLab platform for numerical computation and program interface is simple and easy with knobs. We consider important to model this neutron transport problem with a fixed source in the context of shielding calculations of radiation that protects the biosphere, and could be sensitive to ionizing radiation

  10. Simulation of Lamb wave reflections at plate edges using the semi-analytical finite element method.

    Science.gov (United States)

    Ahmad, Z A B; Gabbert, U

    2012-09-01

    In typical Lamb wave simulation practices, effects of plate edge reflections are often not considered in order to simplify the wave signal interpretations. Methods that are based on infinite plates such as the semi-analytical finite element method is effective in simulating Lamb waves as it excludes the effect of plate edges. However, the inclusion of plate edges in a finite plate could render this method inapplicable, especially for transient response simulations. Here, by applying the ratio of Lamb mode reflections at plate edges, and representing the reflection at plate edges using infinite plate solutions, the semi-analytical finite element method can be applied for transient response simulation, even when the plate is no longer infinite. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  11. Determination of carbendazim, thiabendazole and fuberidazole using a net analyte signal-based method.

    Science.gov (United States)

    Martínez Galera, M; Picón Zamora, D; Martínez Vidal, J L; Garrido Frenich, A; Espinosa-Mansilla, A; Muñoz de la Peña, A; Salinas López, F

    2003-05-01

    The net analyte signal (NAS)-based method HLA/GO, modification of the original hybrid linear analysis (HLA) method, has been used to determine carbendazim, fuberidazole and thiabendazole in water samples. This approach was used after a solid-phase extraction (SPE) step, using the native fluorescence emission spectra of real samples, previously standardized by piecewise direct standardization (PDS). The results obtained show that the modification of HLA performs in a similar way that partial least-squares method (PLS-1). The NAS concept was also used to calculate multivariate analytical figures of merit such as limit of detection, selectivity, sensitivity and analytical sensitivity (gamma(-1)). With this purpose, blanks of methanol and ternary mixtures, with the target analyte at low concentration and the other two ranging according to the calibration matrix, were used, with different results. Detection limits calculated in the last way are more realistic and show the influence of the other components in the sample. Selectivity for carbendazim is higher than the corresponding values for fuberidazole and thiabendazole, whereas sensitivity, as well as the values obtained for their detection limits, are lower for carbendazim, followed by thiabendazole and fuberidazole. Results obtained by modification of HLA vary in the same way that the ones obtained by PLS-1.

  12. Comprehension of complex biological processes by analytical methods: how far can we go using mass spectrometry?

    International Nuclear Information System (INIS)

    Gerner, C.

    2013-01-01

    Comprehensive understanding of complex biological processes is the basis for many biomedical issues of great relevance for modern society including risk assessment, drug development, quality control of industrial products and many more. Screening methods provide means for investigating biological samples without research hypothesis. However, the first boom of analytical screening efforts has passed and we again need to ask whether and how to apply screening methods. Mass spectrometry is a modern tool with unrivalled analytical capacities. This applies to all relevant characteristics of analytical methods such as specificity, sensitivity, accuracy, multiplicity and diversity of applications. Indeed, mass spectrometry qualifies to deal with complexity. Chronic inflammation is a common feature of almost all relevant diseases challenging our modern society; these diseases are apparently highly diverse and include arteriosclerosis, cancer, back pain, neurodegenerative diseases, depression and other. The complexity of mechanisms regulating chronic inflammation is the reason for the practical challenge to deal with it. The presentation shall give an overview of capabilities and limitations of the application of this analytical tool to solve critical questions with great relevance for our society. (author)

  13. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  14. A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens

    OpenAIRE

    Cristina Portalés; Sergio Casas; Inmaculada Coma; Marcos Fernández

    2017-01-01

    The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, w...

  15. A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens

    OpenAIRE

    Portalés Ricart, Cristina; Casas Yrurzum, Sergio; Coma Tatay, Inmaculada; Fernández Marín, Marcos

    2017-01-01

    The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, w...

  16. Precision of a plutonium analytical method using solvent extraction and spectrophotometry

    International Nuclear Information System (INIS)

    Mendoza, P.G.; Jackson, D.D.; Niemczyk, T.M.

    1991-01-01

    The plutonium assay method was investigated that uses the plutonyl trinitrate tetrapropyl-ammonium ion-pair solvent extraction with spectrophotometry of the extract as a candidate method capable of providing robustness and precision. To identify and asses the effect of factors on the precision, we looked at sampling techniques, silver oxide oxidation conditions extraction time, extract stability, and temperature dependence of the extract analytical peak height and position. A precision of 0.12% was obtained. (author) 18 refs.; 2 figs

  17. Analytical methods for drinking water; Metodi di analisi per le acque destinate al consumo umano

    Energy Technology Data Exchange (ETDEWEB)

    Ottaviani, Massimo; Bonadonna, Lucia [Istituto Superiore di Sanita`, Rome (Italy). Lab. di Igiene Ambientale

    1997-03-01

    These analytical methods for drinking water were elaborated by the second Sub-commission of the Permanent study committee ex-article 9 of Italian Ministerial Decree (DM) of March 26, 1991, established at the Ministry of Health. The methods concern the chemical and microbiological parameters included in the C1, C2 and C3 controls of the Annex II of the Decree of the President of the Republic (DPR) 236/88.

  18. A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison

    Science.gov (United States)

    2017-03-01

    This complex connectivity between the drive components was found to be very difficult to model using traditional finite- element methods...components of the ARES could be accurately modeled using finite- elements , modeling the connectivity between the components was found to be significantly...ARL-RP-0592 ● Mar 2017 US Army Research Laboratory A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison by Robert P

  19. International symposium on quality assurance for analytical methods in isotope hydrology. Book of extended synopses

    International Nuclear Information System (INIS)

    2004-01-01

    A large variety of isotopic techniques is available and commonly used in water resources investigations as well as in a wide range of other scientific fields. These techniques include the stable isotope analysis of light elements (H, C, N, O, S), activity measurements of radioactive isotopes at environmental level (3H, 14C, 3H/3He, 85Kr) as well as measurements of CFCs, SF6 and other chemical and isotopic tracers. They provide valuable tools for the assessment of scientific questions and the solution of practical problems. During the last decade, new analytical tools have significantly fostered the application of isotopic techniques in many new fields and caused a steep increase in the number of laboratories applying these methods. International trends in improved analytical quality and requirements for laboratory certification and accreditation have pushed issues of quality control and quality assurance to a high level of importance for the operation of isotope laboratories worldwide. The objectives of the symposium are to promote a wide exchange of information on key issues for high quality isotopic measurements. The main focus is on the analytical techniques and on all means to ensure high quality standards for isotopic measurements. Recent advances in analytical quality assurance and laboratory quality systems will be presented and discussed together with state-of-the-art techniques. The scope of the conference is to demonstrate the use of best laboratory practices in the following fields: calibration of measurements and traceability; interlaboratory comparisons; best laboratory practices for daily analyses of samples; quality control and statistical evaluation of results; calculation of uncertainty budgets; new analytical techniques; improvements in precision and accuracy of analytical methods; laboratory information management, databases and sample handling; laboratory quality systems and international guides. The 42 papers are indexed individually

  20. Fault feature analysis of cracked gear based on LOD and analytical-FE method

    Science.gov (United States)

    Wu, Jiateng; Yang, Yu; Yang, Xingkai; Cheng, Junsheng

    2018-01-01

    At present, there are two main ideas for gear fault diagnosis. One is the model-based gear dynamic analysis; the other is signal-based gear vibration diagnosis. In this paper, a method for fault feature analysis of gear crack is presented, which combines the advantages of dynamic modeling and signal processing. Firstly, a new time-frequency analysis method called local oscillatory-characteristic decomposition (LOD) is proposed, which has the attractive feature of extracting fault characteristic efficiently and accurately. Secondly, an analytical-finite element (analytical-FE) method which is called assist-stress intensity factor (assist-SIF) gear contact model, is put forward to calculate the time-varying mesh stiffness (TVMS) under different crack states. Based on the dynamic model of the gear system with 6 degrees of freedom, the dynamic simulation response was obtained for different tooth crack depths. For the dynamic model, the corresponding relation between the characteristic parameters and the degree of the tooth crack is established under a specific condition. On the basis of the methods mentioned above, a novel gear tooth root crack diagnosis method which combines the LOD with the analytical-FE is proposed. Furthermore, empirical mode decomposition (EMD) and ensemble empirical mode decomposition (EEMD) are contrasted with the LOD by gear crack fault vibration signals. The analysis results indicate that the proposed method performs effectively and feasibility for the tooth crack stiffness calculation and the gear tooth crack fault diagnosis.

  1. Approximate Analytical Solutions of Fractional Perturbed Diffusion Equation by Reduced Differential Transform Method and the Homotopy Perturbation Method

    OpenAIRE

    Zhoujin Cui; Zisen Mao; Sujuan Yang; Pinneng Yu

    2013-01-01

    The approximate analytical solutions of differential equations with fractional time derivative are obtained with the help of a general framework of the reduced differential transform method (RDTM) and the homotopy perturbation method (HPM). RDTM technique does not require any discretization, linearization, or small perturbations and therefore it reduces significantly the numerical computation. Comparing the methodology (RDTM) with some known technique (HPM) shows that the present approach is ...

  2. Application of Scharer's quantitative method for the determination of residual alkaline phosphatase activity in standard Minas

    Directory of Open Access Journals (Sweden)

    C.F. Soares

    2013-08-01

    Full Text Available Milk pasteurization is a critical issue in the dairy industry, and failures in this process can affect final product safety. Scharer's enzymatic method is still traditionally used to verify pasteurization efficiency compliance, and it is based on screening for residual alkaline phosphatase in milk. Although several methods are used to quantify enzymatic activity to assess milk pasteurization efficiency, there is a small amount of published data regarding the use of these methods to quantify alkaline phosphatase in cheese. In this study, the Scharer's modified method was used to determine the levels of residual alkaline phosphatase in standard minas cheese, before and after 20 days of ripening. The cheeses were made using raw or pasteurized milk with the addition of different concentrations of raw milk (0; 0.05%; 0.10%; 0.20%; and 0.50%. In the fresh cheese samples, the method showed a sensitivity of only 0.50% with the addition of raw milk to the pasteurized milk used to make cheese. In addition, levels of up 0.20% of raw milk in pasteurized milk, the concentrations of phenol was inferior to 1μg phenol/g of dairy product which is the preconized indicator value for adequate pasteurization.

  3. Quantitative determination of pefloxacin mesylate by residual-base neutralisation method

    Directory of Open Access Journals (Sweden)

    HULIKALCHANDRA SHEKAR PRAMEELA

    2004-05-01

    Full Text Available This work describes two procedures based on residual base determination for the quantification of pefloxacin mesylate (PFM in bulk drug and in pharmaceutical products. In the first method involving titrimetry, the drug solution is treated with a measured excess of sodium hydroxide followed by back titration of the residual base with hydrochloric acid using a phenol red-bromothymol blue mixed indicator. The second spectrophotometrie method involves treatment of a fixed amount of sodium hydroxide – phenol red mixture with varying amounts of the drug, and measuring the decrease in the absorbance of the dye at 560 nm. In the titrimetric method, a reaction stoichiometry of 1:1 was found in the quantification range of 4–20 mg of drug. The spectrophotometric method allows the determination of PFM in the 5–40 mg ml-1 range. The molar absorptivity is 5.91¤103 l mol-1 cm-1 and the Sandell sensitivity is 56.37 ng cm-2. The methods were applied successfully to the determination of PFM in pharmaceutical preparations.

  4. Wide-Scope Screening Method for Multiclass Veterinary Drug Residues in Fish, Shrimp, and Eel Using Liquid Chromatography-Quadrupole High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R

    2017-08-30

    A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.

  5. Microbial screening for quinolones residues in cow milk by bio-optical method.

    Science.gov (United States)

    Appicciafuoco, Brunella; Dragone, Roberto; Frazzoli, Chiara; Bolzoni, Giuseppe; Mantovani, Alberto; Ferrini, Anna Maria

    2015-03-15

    The use of antibiotics on lactating cows should be monitored for the possible risk of milk contamination with residues. Accordingly, Maximum Residue Levels (MRLs) are established by the European Commission to guarantee consumers safety. As pointed out by Dec 2002/657/EC, screening is the first step in the strategy for antibiotic residue control, thus playing a key role in the whole control procedure. However, current routine screening methods applied in milk chain still fail to detect residues of quinolones at concentrations of interest. This paper reports the findings of a new bio-optical method for the screening of quinolones residues in bovine milk, based on E. coli ATCC 11303 growth inhibition. The effect of blank and spiked cow milk samples (aliquots equivalents to 0.8%, v/v) is evaluated in Mueller Hinton Broth (MHb) and MHb enriched with MgSO4 2% (MHb-Mg) inoculated with the test strain at the concentration of 10(4)CFU/mL. The presence of quinolones inhibits the cellular growth in MHb, while this effect is neutralized in MHb-Mg allowing both detection and presumptive identification of quinolones. Growth of the test strain is monitored at 37 °C in a Bioscreen C automated system, and Optical Density (OD) at 600 nm is recorded every 10 min after shaking for 10s. Growth curves (OD vs. time) of E. coli ATCC 11303 are assessed in milk samples, with and without quinolones, and their differences in terms of ΔOD (ΔOD600nm=ODMHb-Mg-ODMHb) are calculated. The presence of quinolones is detected by the cellular growth inhibition (OD vs time, none increase in the value OD) and presumptively identified through the increase of the slope of ΔOD600nm curve (ΔOD vs. time), after about 3h of incubation. The detection limit for ciprofloxacin and enrofloxacin is at the level of MRL, for marbofloxacin is at 2-fold the MRL whereas for danofloxacin is at 4-fold the MRL. Although the sensitivity of the method could be further improved and the procedure automated, it is a

  6. Analysis of low molecular weight metabolites in tea using mass spectrometry-based analytical methods.

    Science.gov (United States)

    Fraser, Karl; Harrison, Scott J; Lane, Geoff A; Otter, Don E; Hemar, Yacine; Quek, Siew-Young; Rasmussen, Susanne

    2014-01-01

    Tea is the second most consumed beverage in the world after water and there are numerous reported health benefits as a result of consuming tea, such as reducing the risk of cardiovascular disease and many types of cancer. Thus, there is much interest in the chemical composition of teas, for example; defining components responsible for contributing to reported health benefits; defining quality characteristics such as product flavor; and monitoring for pesticide residues to comply with food safety import/export requirements. Covered in this review are some of the latest developments in mass spectrometry-based analytical techniques for measuring and characterizing low molecular weight components of tea, in particular primary and secondary metabolites. The methodology; more specifically the chromatography and detection mechanisms used in both targeted and non-targeted studies, and their main advantages and disadvantages are discussed. Finally, we comment on the latest techniques that are likely to have significant benefit to analysts in the future, not merely in the area of tea research, but in the analytical chemistry of low molecular weight compounds in general.

  7. Mathematical model of complex technical asymmetric system based on numerical-analytical boundary elements method

    Directory of Open Access Journals (Sweden)

    Dina V. Lazareva

    2015-06-01

    Full Text Available A new mathematical model of asymmetric support structure frame type is built on the basis of numerical-analytical boundary elements method (BEM. To describe the design scheme used is the graph theory. Building the model taken into account is the effect of frame members restrained torsion, which presence is due to the fact that these elements are thin-walled. The built model represents a real object as a two-axle semi-trailer platform. To implement the BEM algorithm obtained are analytical expressions of the fundamental functions and vector load components. The effected calculations are based on the semi-trailer two different models, using finite elements and boundary elements methods. The analysis showed that the error between the results obtained on the basis of two numerical methods and experimental data is about 4%, that indicates the adequacy of the proposed mathematical model.

  8. Validation of an analytical method for quality control and stability study of 10 % Phenylephrine eyedrops

    International Nuclear Information System (INIS)

    Monteagudo Licea, Raiza; Garcia Penna, Caridad Margarita; Botet Garcia, Martha

    2010-01-01

    Phenylephrine is used like mydiatric in eye examinations and other ophthalmic procedures. It is used as vasoconstrictor with local anesthetic agents. In present paper a high resolution liquid chromatography analytical method was validated to quality control and stability studies of 10 % Phenylephrine (eyedrops). Method was based in separation of active principle through a Lichrosorb RO-18 (5 μm) (250 x 4 mm) chromatography column with UV detection at 280 nm using a mobile phase composed by a non-gasified mixture of methanol distilled water (1:1) with 1.1 g of 1-sodium octane-sulphonate by liter adjusted to pH 3,0 with phosphoric acid at a flow speed of 1.0 mL/min. Analytical method was linear, accuracy, specific and exact in the interval of study concentrations

  9. Validation of analytical method for quality control of B12 Vitamin-10 000 injection

    International Nuclear Information System (INIS)

    Botet Garcia, Martha; Garcia Penna, Caridad Margarita; Troche Concepcion, Yenilen; Cannizares Arencibia, Yanara; Moreno Correoso, Barbara

    2009-01-01

    Analytical method reported by USA Pharmacopeia was validated for quality control of injectable B 1 2 Vitamin (10 000 U) by UV spectrophotometry because this is a simpler and low-cost method allowing quality control of finished product. Calibration curve was graphed at 60 to 140% interval, where it was linear with a correlation coefficient similar to 0, 9999; statistical test for interception and slope was considered non-significant. There was a recovery of 99.7 % in study concentrations interval where the Cochran (G) and Student(t) test were not significant too. Variation coefficient in repetition study was similar to 0.59 % for the 6 assayed replies, whereas in intermediate precision analysis, the Fisher and Student tests were not significant. Analytical method was linear, precise, specific and exact in study concentrations interval

  10. Analytical method validation for quality control and the study of the 50 mg Propylthiouracil stability

    International Nuclear Information System (INIS)

    Valdes Bendoyro, Maria Olga; Garcia Penna, Caridad Margarita; Fernandez, Juan Lugones; Garcia Borges, Lisandra; Martinez Espinosa, Vivian

    2010-01-01

    A high-performance liquid chromatography analytical method was developed and validated for the quality control and stability studies of 50 mg Propylthiouracil tablets. Method is based in active principle separation through a 100 RP-18 RP-18 (5 μm) (250 x 4 mm) Lichrospher chromatography with UV detection to 272 nm, using a mobile phase composed by a ungaseous mixture of a 0.025 M buffer solution-monobasic potassium phosphate to pH= 4,6 ad acetonitrile in a 80:20 ratio with a flux speed of 0,5 mL/min. Analytical method was linear, precise, specific and exact in the study concentrations interval

  11. Besifloxacin: A Critical Review of Its Characteristics, Properties, and Analytical Methods.

    Science.gov (United States)

    Tótoli, Eliane Gandolpho; Salgado, Hérida Regina Nunes

    2018-03-04

    Bacterial conjunctivitis has high impact on the health of the population, since it represents more than a third of ocular pathologies reported by health services worldwide. There is a high incidence of bacterial resistance to the antimicrobials most commonly used for the treatment of conjunctivitis. In this context, besifloxacin stands out, since it is a fluoroquinolone developed exclusively for topical ophthalmic use, presenting a low risk of developing resistance due to its reduced systemic exposure. Bausch & Lomb markets it as ophthalmic suspension, under the trade name Besivance™. Literature review on besifloxacin is presented, covering its pharmaceutical and clinical characteristics, and the analytical methods used to measure the drug in pharmaceutical products and biological samples. High performance liquid chromatography is the most used method for this purpose. A discussion on Green Chemistry is also presented, focusing the importance of the development of green analytical methods for the analysis of drugs.

  12. Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce

    NARCIS (Netherlands)

    Mol, J.G.J.; Rooseboom, A.; Dam, van R.; Roding, M.; Arondeus, K.; Sunarto, S.

    2007-01-01

    The ethyl acetate-based multi-residue method for determination of pesticide residues in produce has been modified for gas chromatographic (GC) analysis by implementation of dispersive solid-phase extraction (using primary¿secondary amine and graphitized carbon black) and large-volume (20 ¿L)

  13. Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce

    NARCIS (Netherlands)

    Mol, H.G.J.; Rooseboom, A.; Dam, R. van; Roding, M.; Arondeus, K.; Sunarto, S.

    2007-01-01

    The ethyl acetate-based multi-residue method for determination of pesticide residues in produce has been modified for gas chromatographic (GC) analysis by implementation of dispersive solid-phase extraction (using primary-secondary amine and graphitized carbon black) and large-volume (20 μL)

  14. A method for assessing residual NAPL based on organic chemical concentrations in soil samples

    International Nuclear Information System (INIS)

    Feenstra, S.; Mackay, D.M.; Cherry, J.A.

    1991-01-01

    Ground water contamination by non-aqueous phase liquid (NAPL) chemicals is a serious concern at many industrial facilities and waste disposal sites. NAPL in the form of immobile residual contamination, or pools of mobile or potentially mobile NAPL, can represent continuing sources of ground water contamination. In order to develop rational and cost-effective plans for remediation of soil and ground water contamination at such sites, it is essential to determine if non-aqueous phase liquid (NAPL) chemicals are present in the subsurface and delineate the zones of NAPL contamination. Qualitatively, soil analyses that exhibit chemical concentrations in the percent range or >10,000 mg/kg would generally be considered to indicate the presence of NAPL. However, the results of soil analyses are seldom used in a quantitative manner to assess the possible presence of residual NAPL contamination when chemical concentrations are lower and the presence of NAPL is not obvious. The assessment of the presence of NAPL in soil samples is possible using the results of chemical and physical analyses of the soil, and the fundamental principles of chemical partitioning in unsaturated or saturated soil. The method requires information on the soil of the type typically considered in ground water contamination studies and provides a simple tool for the investigators of chemical spill and waste disposal sites to assess whether soil chemical analyses indicate the presence of residual NAPL in the subsurface

  15. Validation of HPLC method of analysis of tetracycline residues in eggs and broiler meat and its application to a feeding trial.

    Science.gov (United States)

    De Ruyck, H; De Ridder, H; Van Renterghem, R; Van Wambeke, F

    1999-02-01

    HPLC with ion-pairing chromatography and diodearray detection at 355 nm was used to determine tetracycline antibiotics in eggs and broiler meat. The analytical methods were optimized and validated. The mean recovery values for oxytetracycline for eggs and for tetracycline for breast meat were 76%. The within-day precision ranged from 8.0 to 11.8% for oxytetracycline in eggs and from 6.1 to 15.5% for tetracycline in breast meat. The between-day precision was 4.8% and 5.0% respectively for oxytetracycline in eggs and tetracycline in breast meat. The limit of detection and the limit of quantitation for oxytetracycline in eggs were 2.2 and 13.0 ng/g respectively. These limits for tetracycline in breast meat were 10.5 and 20.9 ng/g respectively. Residue values of tetracycline antibiotics in eggs and broiler meat were determined after oral administration of medicated feed. Medicated feed with 840 mg/kg oxytetracycline was provided to laying hens for seven successive days. Two days after the administration was stopped, the mean oxytetracycline residue value in the eggs was already lower than the Maximum Residue Limit (MRL)-level and reached 118 ng/g. Broilers were supplied with medicated feed containing 480 mg/kg tetracycline for seven successive days. Four days after the administration was stopped, the mean tetracycline residue value in breast meat decreased below the MRL and was 86 ng/g.

  16. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  17. Analytical methods for the determination of personal care products in human samples: an overview.

    Science.gov (United States)

    Jiménez-Díaz, I; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2014-11-01

    Personal care products (PCPs) are organic chemicals widely used in everyday human life. Nowadays, preservatives, UV-filters, antimicrobials and musk fragrances are widely used PCPs. Different studies have shown that some of these compounds can cause adverse health effects, such as genotoxicity, which could even lead to mutagenic or carcinogenic effects, or estrogenicity because of their endocrine disruption activity. Due to the absence of official monitoring protocols, there is an increasing demand of analytical methods that allow the determination of those compounds in human samples in order to obtain more information regarding their behavior and fate in the human body. The complexity of the biological matrices and the low concentration levels of these compounds make necessary the use of advanced sample treatment procedures that afford both, sample clean-up, to remove potentially interfering matrix components, as well as the concentration of analytes. In the present work, a review of the more recent analytical methods published in the scientific literature for the determination of PCPs in human fluids and tissue samples, is presented. The work focused on sample preparation and the analytical techniques employed. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Analytical maximum-likelihood method to detect patterns in real networks

    International Nuclear Information System (INIS)

    Squartini, Tiziano; Garlaschelli, Diego

    2011-01-01

    In order to detect patterns in real networks, randomized graph ensembles that preserve only part of the topology of an observed network are systematically used as fundamental null models. However, the generation of them is still problematic. Existing approaches are either computationally demanding and beyond analytic control or analytically accessible but highly approximate. Here, we propose a solution to this long-standing problem by introducing a fast method that allows one to obtain expectation values and standard deviations of any topological property analytically, for any binary, weighted, directed or undirected network. Remarkably, the time required to obtain the expectation value of any property analytically across the entire graph ensemble is as short as that required to compute the same property using the adjacency matrix of the single original network. Our method reveals that the null behavior of various correlation properties is different from what was believed previously, and is highly sensitive to the particular network considered. Moreover, our approach shows that important structural properties (such as the modularity used in community detection problems) are currently based on incorrect expressions, and provides the exact quantities that should replace them.

  19. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    Science.gov (United States)

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  20. An analytically based numerical method for computing view factors in real urban environments

    Science.gov (United States)

    Lee, Doo-Il; Woo, Ju-Wan; Lee, Sang-Hyun

    2018-01-01

    A view factor is an important morphological parameter used in parameterizing in-canyon radiative energy exchange process as well as in characterizing local climate over urban environments. For realistic representation of the in-canyon radiative processes, a complete set of view factors at the horizontal and vertical surfaces of urban facets is required. Various analytical and numerical methods have been suggested to determine the view factors for urban environments, but most of the methods provide only sky-view factor at the ground level of a specific location or assume simplified morphology of complex urban environments. In this study, a numerical method that can determine the sky-view factors ( ψ ga and ψ wa ) and wall-view factors ( ψ gw and ψ ww ) at the horizontal and vertical surfaces is presented for application to real urban morphology, which are derived from an analytical formulation of the view factor between two blackbody surfaces of arbitrary geometry. The established numerical method is validated against the analytical sky-view factor estimation for ideal street canyon geometries, showing a consolidate confidence in accuracy with errors of less than 0.2 %. Using a three-dimensional building database, the numerical method is also demonstrated to be applicable in determining the sky-view factors at the horizontal (roofs and roads) and vertical (walls) surfaces in real urban environments. The results suggest that the analytically based numerical method can be used for the radiative process parameterization of urban numerical models as well as for the characterization of local urban climate.

  1. Milk urea analytical result reliability and its methodical possibilities in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Jan Říha

    2013-01-01

    Full Text Available Control of milk urea concentration (MUC can be used in diagnosis of the energy–nitrogen metabolism of cows. There are more analytical methods for MUC estimation and there are also discussions about their result reliability. Aim of this work was to obtain information for MUC result reliability improvement. MUC and MUN (milk urea nitrogen were investigated in 5 milk sample sets and in 7 calibration/comparison experiments. The positions of reference and indirect methods were changed in experiments. There were following analytical methods for MUC or MUN (in mg.100 ml−1: – photometric method (PH, as reference based on paradimethylaminobenzaldehyde reaction; – method Ureakvant (UK, as reference based on difference measurement of the electrical conductivity change during ureolysis; – method Chemspec (CH based on photometrical measurement of ammonia concentration after ureolysis (as reference; – spectroscopic method in mid infrared range of spectrum (FT–MIR; indirect routine method. In all methodical combinations the correlation coefficients (r varied from 0.8803 to 0.9943 (P −1 and comparable values of repeatability (from 0.65 to 1.83 mg.100 ml−1 as compared to FT–MIR MUC or MUN methods (from 1.39 to 5.6 and from 0.76 to 1.92 mg.100 ml−1 in performed experiments.

  2. Use of a dynamic grid adaptation in the asymmetric weighted residual method

    International Nuclear Information System (INIS)

    Graf, V.; Romstedt, P.; Werner, W.

    1986-01-01

    A dynamic grid adaptive method has been developed for use with the asymmetric weighted residual method. The method automatically adapts the number and position of the spatial mesh points as the solution of hyperbolic or parabolic vector partial differential equations progresses in time. The mesh selection algorithm is based on the minimization of the L 2 norm of the spatial discretization error. The method permits the accurate calculation of the evolution of inhomogeneities, like wave fronts, shock layers, and other sharp transitions, while generally using a coarse computational grid. The number of required mesh points is significantly reduced, relative to a fixed Eulerian grid. Since the mesh selection algorithm is computationally inexpensive, a corresponding reduction of computing time results

  3. Comparison between some determination methods of residual styrene in plastic scintillators

    International Nuclear Information System (INIS)

    Bezuglyi, V.D.; Ponomarev, Yu.P.; Gunder, O.A.; Biteman, V.B.; Senchishin, V.G.

    1988-01-01

    Scintillators made of plastic materials based on polystyrene with addition of p-terphenyl and 1,4-di-[(2,5-phenyl)oxazolyl] benzene have found wide application principally in the detection of radioactivity. The stability of the scintillating characteristics of these materials depends to great degree on the concentration of the residual monomer and for this reason it is important to have a sufficiently convenient method for the determination of this latter. We investigated the bromometric and acid-base titration methods with visual and potentiometric titration end point detection. We also examined the polarographic methods, direct and indirect, using the electroreduction of the mercury acetate complex of the monomer. We checked the methods on a scintillator sample and on synthetic mixtures, i.e., mixtures of monomer, polymer, and p-terphenyl. We compared the determination results for styrene and showed that the most accurate procedure is the bromometric determination with potentiometric indication of the end-point

  4. Development of an on-site measurement method for residual stress in primary system piping of nuclear power plants

    International Nuclear Information System (INIS)

    Maekawa, Akira; Takahashi, Shigeru; Fujiwara, Masaharu

    2014-01-01

    In residual stress measurement for large-scale pipes and vessels in high radiation areas and highly contaminated areas of nuclear plants, it is difficult to bring the radioactivated pipes and vessels out of the areas as they are. If they can brought out, it is very burdensome to handle them for the measurement. Development of an on-site measurement method of residual stress which can be quickly applied and has sufficient measurement accuracy is desirable. In this study, a new method combining an electric discharge skim-cut method with a microscopic strain measurement method using markers was proposed to realize the on-site residual stress measurement on pipes in high radiation areas and highly contaminated areas. In the electric discharge skim-cut method, a boat-type sample is skimmed out of a pipe outer/inner surface using electric discharge machining and released residual stress is measured. The on-site measurement of residual stress by the method can be done using a small, portable electric discharge machine. In the microscopic strain measurement method using markers, the residual stress is estimated by microscopic measurement of the distance between markers after the stress release. The combination of both methods can evaluate the residual stress with the same accuracy as conventional methods offer and it can achieve reduction of radiation exposure in the measurement because the work is done simply and rapidly. In this study, the applicability of the electric discharge skim-cut method was investigated because the applicability of the microscopic strain measurement method using markers was confirmed previously. The experimental examination clarified the applicable conditions for the residual stress measurement with the same accuracy as the conventional methods. Furthermore, the electric discharge machining conditions using pure water as the machining liquid was found to eliminate the amount of liquid radioactive waste completely. (author)

  5. Analytical Methods for Malachite Green : Completion Report : Malachite Green Analysis in Water.

    Energy Technology Data Exchange (ETDEWEB)

    Allen, John L.; Gofus, Jane E.; Meinertz, Jeffery R.

    1991-06-01

    Malachite green is a known teratogen and therefore its use is limited to nonfood fish under an Investigational New Animal Drug permit (INAD), number 2573. Although a charcoal adsorption column was developed to remove malachite green from hatchery water, INAD compliance requires that the malachite green residue concentrations in any effluent from hatcheries using the chemical be quantified. Therefore, we developed a method for the analysis of malachite green residues in water. Enrichment of the residues of malachite green in water on a diol column followed by High Performance Liquid Chromatographic (HPLC) analysis gives a minimum sensitivity of less than 10 ppb for the chemical. When combined with post-column oxidation using a lead oxide post-column reactor, the procedure can be used for the simultaneous analysis of malachite green in its leuco form, a decomposition product of the dye, as well as its chromatic form. Recovery of the leuco form is pH dependent and water samples should be adjusted to pH 6 to optimize recovery of this form. Water samples spiked with malachite green were concentrated on a diol column followed by elution with 0.05 M p-toluene sulfonic acid in methanol. The methanol elutes were analyzed by HPLC. Pond water samples spiked with malachite green and leuco malachite green yielded average recoveries of 95.4% for malachite green and 57.3% for leuco malachite green. Tap water samples spiked with the carbinol form of malachite green gave average recoveries of 98.6%. The method is very sensitive and is capable of detecting malachite green residues in water at less than 10 ppb. Fish culturists, who cannot find an effective replacement for malachite green, can utilize the method to ensure that their effluents comply with INAD regulations. 13 refs., 2 figs., 7 tabs.

  6. A finite volume method for cylindrical heat conduction problems based on local analytical solution

    KAUST Repository

    Li, Wang

    2012-10-01

    A new finite volume method for cylindrical heat conduction problems based on local analytical solution is proposed in this paper with detailed derivation. The calculation results of this new method are compared with the traditional second-order finite volume method. The newly proposed method is more accurate than conventional ones, even though the discretized expression of this proposed method is slightly more complex than the second-order central finite volume method, making it cost more calculation time on the same grids. Numerical result shows that the total CPU time of the new method is significantly less than conventional methods for achieving the same level of accuracy. © 2012 Elsevier Ltd. All rights reserved.

  7. A new one-platform flow cytometric method for residual cell counting in platelet concentrates.

    Science.gov (United States)

    Schmidt, Michael; Spengler, Hans-Peter; Lambrecht, Bernd; Hourfar, Michael K; Seifried, Erhard; Tonn, Torsten

    2009-12-01

    According to German regulations and guidelines, residual red blood cells (rRBCs) and residual white blood cells (rWBCs) must number fewer than 3 x 10(9) cells/unit and 1 x 10(6) cells/unit in platelet concentrates (PCs), respectively. Due to low levels of residual cells in final products, there is still a need for fast, reliable, and sensitive methods of automated detection of these cell types. In Part A, 21 PCs were spiked with predetermined numbers of red blood cells (RBCs) and white blood cells (WBCs). The linearity, precision, and accuracy of the BD Thrombo Count assay (BD Biosciences Europe) were tested and validated according to international guidelines. Finally in Part B, 100 PCs prepared from pooled buffy coats were tested by the BD Thrombo Count assay and compared with other methods, including Nageotte (rWBCs) and Neubauer (rRBCs) counting chambers and the flow cytometric BD LeucoCOUNT (Becton Dickinson) assay (rWBCs). The unspecific background of blank PC samples was fewer than 0.02 cells/microL for WBCs and fewer than 34 cells/microL for RBCs (mean, 21). Linear regression and precision analyses of spiked PC samples were determined for both WBCs (r(2) = 0.992; range, 0.6-6.0 WBCs/microL) and RBCs (r(2) = 0.999; 800-8000 RBCs/microL). No carryover of cells or drift in results was detected in the automated sample acquisition mode. Analysis according to statistical methods of Bland and Altman demonstrated a high correlation between BD Thrombo Count and the Neubauer manual counting chamber. This novel flow cytometric test is a quick and reliable single-tube assay that has been demonstrated as a potential alternative for the existing manual microscopic counting procedures that are both time-consuming and laborious.

  8. Evaluation of residual antibacterial potency in antibiotic production wastewater using a real-time quantitative method.

    Science.gov (United States)

    Zhang, Hong; Zhang, Yu; Yang, Min; Liu, Miaomiao

    2015-11-01

    While antibiotic pollution has attracted considerable attention due to its potential in promoting the dissemination of antibiotic resistance genes in the environment, the antibiotic activity of their related substances has been neglected, which may underestimate the environmental impacts of antibiotic wastewater discharge. In this study, a real-time quantitative approach was established to evaluate the residual antibacterial potency of antibiotics and related substances in antibiotic production wastewater (APW) by comparing the growth of a standard bacterial strain (Staphylococcus aureus) in tested water samples with a standard reference substance (e.g. oxytetracycline). Antibiotic equivalent quantity (EQ) was used to express antibacterial potency, which made it possible to assess the contribution of each compound to the antibiotic activity in APW. The real-time quantitative method showed better repeatability (Relative Standard Deviation, RSD 1.08%) compared with the conventional fixed growth time method (RSD 5.62-11.29%). And its quantification limits ranged from 0.20 to 24.00 μg L(-1), depending on the antibiotic. We applied the developed method to analyze the residual potency of water samples from four APW treatment systems, and confirmed a significant contribution from antibiotic transformation products to potent antibacterial activity. Specifically, neospiramycin, a major transformation product of spiramycin, was found to contribute 13.15-22.89% of residual potency in spiramycin production wastewater. In addition, some unknown related substances with antimicrobial activity were indicated in the effluent. This developed approach will be effective for the management of antibacterial potency discharge from antibiotic wastewater and other waste streams.

  9. Determination of cyflumetofen residue in water, soil, and fruits by modified quick, easy, cheap, effective, rugged, and safe method coupled to gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Li, Minmin; Liu, Xingang; Dong, Fengshou; Xu, Jun; Qin, Dongmei; Zheng, Yongquan

    2012-10-01

    A new, highly sensitive, and selective method was developed for the determination of the cyflumetofen residue in water, soil, and fruits by using gas chromatography quadruple mass spectrometry. The target compound was extracted using acetonitrile and then cleaned up using dispersive solid-phase extraction with primary and secondary amine and graphitized carbon black, and optionally by a freezing-out cleanup step. The matrix-matched standards gave satisfactory recoveries and relative standard deviation values in different matrices at three fortified levels (0.05, 0.5, and 1.0 mg kg(-1) ). The overall average recoveries for this method in water, soil, and all fruits matrix at three fortified levels ranged from 76.3 to 101.5% with relative standard deviations in the range of 1.2-11.8% (n = 5). The calculated limits of detection and quantification were typically below 0.005 and 0.015 μg kg(-1), which were much lower than the maximum residue levels established by Japanese Positive List. This study provides a theoretical basis for China to draw up maximum residue level and analytical method for cyflumetofen acaricide in different fruits. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Formulation and Development of a Validated UV-Spectrophotometric Analytical Method of Rutin Tablet

    Directory of Open Access Journals (Sweden)

    Murad N. Abualhasan

    2017-01-01

    Full Text Available Rutin is available in some foods, fruits, and vegetables. It has various beneficial medical effects making it useful in the treatment of various diseases. Rutin is available in different oral dosage forms such as tablets or capsules, widely available in the market. Rutin and many herbal medicines lack quality control due to unavailability of analytical methods. In this study, we formulated rutin tablet and studied its stability using a simple developed analytical method. The dissolution profile of our formulated tablet was also inspected. The results showed that our developed method was linear (R2=0.999, precise (% RSD = 0.026, and accurate (% recovery = 98.55–103.34. The formulated rutin tablet was stable under accelerated conditions as well as room temperature for 150 days (% assay > 91.69. The dissolution profile over 45 minutes of our formulated tablet showed a better dissolution (26.5% compared with the internationally marketed Rutin® tablet (18.5%. This study can serve as a guideline to companies that manufacture herbal products to improve their formulated herbs and apply validated analytical methods to check the quality of their product.

  11. Analytical design method of a device for ultrasonic elliptical vibration cutting.

    Science.gov (United States)

    Huang, Weihai; Yu, Deping; Zhang, Min; Ye, Fengfei; Yao, Jin

    2017-02-01

    Ultrasonic elliptical vibration cutting (UEVC) is effective in ultraprecision diamond cutting of hard-brittle materials and ferrous metals. However, its design is quite empirical and tedious. This paper proposes an analytical design method for developing the UEVC device which works at the Flexural-Flexural complex-mode to generate the elliptical vibration. For such UEVC device, the resonant frequencies of the two flexural vibrations are required to be the same. In addition, the nodal points of the two flexural vibrations should be coincident so that the device can be clamped without affecting the vibrations. Based on the proposed analytical design method, an UEVC device was first designed. Modal analysis of the designed UEVC device was performed by using the finite element method, which shows that the resonant frequencies coincide well with the targeted ones. Then a prototype UEVC device was fabricated, and its vibration characteristics were measured by an impedance analyzer and a laser displacement sensor. Experimental results indicate that the designed UEVC device can generate elliptical vibration with the resonant frequencies closed to the target ones. In addition, the vibration trajectory can be precisely tuned by adjusting the phase difference and the amplitude of the applied voltage. Simulation and experimental results validated the effectiveness of the analytical design method.

  12. Comparison of the calculated neutron noise using finite differences and the Analytical Nodal Method

    International Nuclear Information System (INIS)

    Larsson, Viktor; Demazière, Christophe

    2012-01-01

    Highlights: ► Numerical neutron noise calculations for a commercial PWR. ► Comparison using finite differences and the Analytical Nodal Method. ► Little gain for the higher cost of more advanced methods. ► Finite difference adequate for neutron noise calculations. - Abstract: In this paper, a comparison of the calculated neutron noise, i.e. the fluctuation of the neutron flux around its average value assuming that all processes are stationary, is conducted, where the neutron noise is calculated using finite differences alone and with finite differences where the Analytical Nodal Method is used to correct the neutron currents, respectively. It is seen that the lower the frequency of the noise source, the larger difference between the two solutions. The main conclusion from this work is that the gain of calculating the neutron noise using the more sophisticated Analytical Nodal Method compared to the increase of the corresponding computational burden is too little to motivate the use of the ANM.

  13. Characteristics, Properties and Analytical Methods of Amoxicillin: A Review with Green Approach.

    Science.gov (United States)

    de Marco, Bianca Aparecida; Natori, Jéssica Sayuri Hisano; Fanelli, Stefany; Tótoli, Eliane Gandolpho; Salgado, Hérida Regina Nunes

    2017-05-04

    Bacterial infections are the second leading cause of global mortality. Considering this fact, it is extremely important studying the antimicrobial agents. Amoxicillin is an antimicrobial agent that belongs to the class of penicillins; it has bactericidal activity and is widely used in the Brazilian health system. In literature, some analytical methods are found for the identification and quantification of this penicillin, which are essential for its quality control, which ensures maintaining the product characteristics, therapeutic efficacy and patient's safety. Thus, this study presents a brief literature review on amoxicillin and the analytical methods developed for the analysis of this drug in official and scientific papers. The major analytical methods found were high-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (U-HPLC), capillary electrophoresis and iodometry and diffuse reflectance infrared Fourier transform. It is essential to note that most of the developed methods used toxic and hazardous solvents, which makes necessary industries and researchers choose to develop environmental-friendly techniques to provide enhanced benefits to environment and staff.

  14. A Semi-Analytical Method for the PDFs of A Ship Rolling in Random Oblique Waves

    Science.gov (United States)

    Liu, Li-qin; Liu, Ya-liu; Xu, Wan-hai; Li, Yan; Tang, You-gang

    2018-03-01

    The PDFs (probability density functions) and probability of a ship rolling under the random parametric and forced excitations were studied by a semi-analytical method. The rolling motion equation of the ship in random oblique waves was established. The righting arm obtained by the numerical simulation was approximately fitted by an analytical function. The irregular waves were decomposed into two Gauss stationary random processes, and the CARMA (2, 1) model was used to fit the spectral density function of parametric and forced excitations. The stochastic energy envelope averaging method was used to solve the PDFs and the probability. The validity of the semi-analytical method was verified by the Monte Carlo method. The C11 ship was taken as an example, and the influences of the system parameters on the PDFs and probability were analyzed. The results show that the probability of ship rolling is affected by the characteristic wave height, wave length, and the heading angle. In order to provide proper advice for the ship's manoeuvring, the parametric excitations should be considered appropriately when the ship navigates in the oblique seas.

  15. Residual-based a posteriori error estimation for multipoint flux mixed finite element methods

    KAUST Repository

    Du, Shaohong

    2015-10-26

    A novel residual-type a posteriori error analysis technique is developed for multipoint flux mixed finite element methods for flow in porous media in two or three space dimensions. The derived a posteriori error estimator for the velocity and pressure error in L-norm consists of discretization and quadrature indicators, and is shown to be reliable and efficient. The main tools of analysis are a locally postprocessed approximation to the pressure solution of an auxiliary problem and a quadrature error estimate. Numerical experiments are presented to illustrate the competitive behavior of the estimator.

  16. [Research on rapid and quantitative detection method for organophosphorus pesticide residue].

    Science.gov (United States)

    Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming

    2014-05-01

    The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm

  17. Generation and importance of linked and irreducible moment diagrams in the recursive residue generation method

    International Nuclear Information System (INIS)

    Schek, I.; Wyatt, R.E.

    1986-01-01

    Molecular multiphoton processes are treated in the Recursive Residue Generation Method (A. Nauts and R.E. Wyatt, Phys. Rev. Lett 51, 2238 (1983)) by converting the molecular-field Hamiltonian matrix into tridiagonal form, using the Lanczos equations. In this study, the self-energies (diagonal) and linking (off-diagaonal) terms in the tridiagonal matrix are obtained by comparing linked moment diagrams in both representations. The dynamics of the source state is introduced and computed in terms of the linked and the irreducible moments

  18. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    Science.gov (United States)

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Comparative analysis of different methods of extraction of present hydrocarbons in industrial residual waters

    International Nuclear Information System (INIS)

    Santa, Judith Rocio; Serrano, Martin; Stashenko, Elena

    2002-01-01

    A comparison among four extraction techniques such as: liquid - liquid (LLE) continuous and for lots, solid phase extraction (SPE), solid phase micro extraction (SPME) and static headspace (S-HS) was carried out. The main purpose of this research was to determine the highest recovery efficiencies and how reproducible the tests are while varying parameters such as time, extraction technique, type of solvents and others. Chromatographic parameters were optimized in order to carry out the analyses. Hydrocarbon's quantification of residual waters was achieved by using a high-resolution gas chromatography with a gas flame ionization detector (HRGC-FID). Validation of the method was carried out by analyzing real samples taken in different sampling places of the residual waters treatment plant of Ecopetrol - Barrancabermeja. The use of extraction methods that require big solvent quantities and long time for analysis are losing validity day by day. Techniques such as the HS-SPME and static HS are offered as alternatives for quantifying hydrocarbons. They show total lack of solvents, high sensibility, selectivity and the techniques are reproducible. Solid phase micro extraction (SPME) and static headspace (static HS) techniques were chosen as the extraction techniques to validate the method in real samples. Both techniques showed similar results for the determination of total hydrocarbons (in the gasoline range)

  20. Effect of the sequence data deluge on the performance of methods for detecting protein functional residues.

    Science.gov (United States)

    Garrido-Martín, Diego; Pazos, Florencio

    2018-02-27

    The exponential accumulation of new sequences in public databases is expected to improve the performance of all the approaches for predicting protein structural and functional features. Nevertheless, this was never assessed or quantified for some widely used methodologies, such as those aimed at detecting functional sites and functional subfamilies in protein multiple sequence alignments. Using raw protein sequences as only input, these approaches can detect fully conserved positions, as well as those with a family-dependent conservation pattern. Both types of residues are routinely used as predictors of functional sites and, consequently, understanding how the sequence content of the databases affects them is relevant and timely. In this work we evaluate how the growth and change with time in the content of sequence databases affect five sequence-based approaches for detecting functional sites and subfamilies. We do that by recreating historical versions of the multiple sequence alignments that would have been obtained in the past based on the database contents at different time points, covering a period of 20 years. Applying the methods to these historical alignments allows quantifying the temporal variation in their performance. Our results show that the number of families to which these methods can be applied sharply increases with time, while their ability to detect potentially functional residues remains almost constant. These results are informative for the methods' developers and final users, and may have implications in the design of new sequencing initiatives.

  1. Assessment of Protein Side-Chain Conformation Prediction Methods in Different Residue Environments

    Science.gov (United States)

    Peterson, Lenna X.; Kang, Xuejiao; Kihara, Daisuke

    2016-01-01

    Computational prediction of side-chain conformation is an important component of protein structure prediction. Accurate side-chain prediction is crucial for practical applications of protein structure models that need atomic detailed resolution such as protein and ligand design. We evaluated the accuracy of eight side-chain prediction methods in reproducing the side-chain conformations of experimentally solved structures deposited to the Protein Data Bank. Prediction accuracy was evaluated for a total of four different structural environments (buried, surface, interface, and membrane-spanning) in three different protein types (monomeric, multimeric, and membrane). Overall, the highest accuracy was observed for buried residues in monomeric and multimeric proteins. Notably, side-chains at protein interfaces and membrane-spanning regions were better predicted than surface residues even though the methods did not all use multimeric and membrane proteins for training. Thus, we conclude that the current methods are as practically useful for modeling protein docking interfaces and membrane-spanning regions as for modeling monomers. PMID:24619909

  2. Characterization of Compton-scatter imaging with an analytical simulation method

    Science.gov (United States)

    Jones, Kevin C.; Redler, Gage; Templeton, Alistair; Bernard, Damian; Turian, Julius V.; Chu, James C. H.

    2018-01-01

    By collimating the photons scattered when a megavoltage therapy beam interacts with the patient, a Compton-scatter image may be formed without the delivery of an extra dose. To characterize and assess the potential of the technique, an analytical model for simulating scatter images was developed and validated against Monte Carlo (MC). For three phantoms, the scatter images collected during irradiation with a 6 MV flattening-filter-free therapy beam were simulated. Images, profiles, and spectra were compared for different phantoms and different irradiation angles. The proposed analytical method simulates accurate scatter images up to 1000 times faster than MC. Minor differences between MC and analytical simulated images are attributed to limitations in the isotropic superposition/convolution algorithm used to analytically model multiple-order scattering. For a detector placed at 90° relative to the treatment beam, the simulated scattered photon energy spectrum peaks at 140-220 keV, and 40-50% of the photons are the result of multiple scattering. The high energy photons originate at the beam entrance. Increasing the angle between source and detector increases the average energy of the collected photons and decreases the relative contribution of multiple scattered photons. Multiple scattered photons cause blurring in the image. For an ideal 5 mm diameter pinhole collimator placed 18.5 cm from the isocenter, 10 cGy of deposited dose (2 Hz imaging rate for 1200 MU min-1 treatment delivery) is expected to generate an average 1000 photons per mm2 at the detector. For the considered lung tumor CT phantom, the contrast is high enough to clearly identify the lung tumor in the scatter image. Increasing the treatment beam size perpendicular to the detector plane decreases the contrast, although the scatter subject contrast is expected to be greater than the megavoltage transmission image contrast. With the analytical method, real-time tumor tracking may be possible

  3. Residual stress measurement of EB-welded plates with contour method. Part 2: FEM analysis of contour profiles

    International Nuclear Information System (INIS)

    Romppanen, A.-J.; Immonen, E.

    2013-12-01

    The residual stresses formed as a result of Electronic Beam welding (EB-welding) in copper are investigated by Posiva. In the present study, residual stresses of EB-welded copper plates were studied with contour method. In the method eleven copper plates (X436 - X440 and X453 - X458) were cut in half with wire electric discharge machining (EDM) after which the deformation due to stress relaxation was measured with coordinate measurement system. The measured data was then used as boundary displacement data for the FEM analyses, in which the corresponding residual stresses were calculated. Before giving the corresponding displacement boundary conditions to the FE models, the deformation data was processed and smoothed appropriately. The residual stress levels of the copper plates were found to be around 40 - 55 MPa at maximum. This corresponds to other reported residual stress measurements and current state of knowledge with this material in Posiva. (orig.)

  4. Analytical methods for determination of terbinafine hydrochloride in pharmaceuticals and biological materials

    Directory of Open Access Journals (Sweden)

    Basavaiah Kanakapura

    2016-06-01

    Full Text Available Terbinafine is a new powerful antifungal agent indicated for both oral and topical treatment of mycosessince. It is highly effective in the treatment of determatomycoses. The chemical and pharmaceutical analysis of the drug requires effective analytical methods for quality control and pharmacodynamic and pharmacokinetic studies. Ever since it was introduced as an effective antifungal agent, many methods have been developed and validated for its assay in pharmaceuticals and biological materials. This article reviews the various methods reported during the last 25 years.

  5. Selection of analytical methods for mixed waste analysis at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Morant, P.M.

    1994-09-01

    This document describes the process that the US Department of Energy (DOE), Richland Operations Office (RL) and contractor laboratories use to select appropriate or develop new or modified analytical methods. These methods are needed to provide reliable mixed waste characterization data that meet project-specific quality assurance (QA) requirements while also meeting health and safety standards for handling radioactive materials. This process will provide the technical basis for DOE`s analysis of mixed waste and support requests for regulatory approval of these new methods when they are used to satisfy the regulatory requirements of the Hanford Federal Facility Agreement and Consent Order (Tri-party Agreement) (Ecology et al. 1992).

  6. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  7. Free and Forced Vibration Analysis of an Infilled Steel Frame: Experimental, Numerical, and Analytical Methods

    Directory of Open Access Journals (Sweden)

    Mohammad Amin Hariri-Ardebili

    2014-01-01

    Full Text Available Structural frames with masonry infill panels make up a significant portion of the buildings constructed in earthquake-prone areas prior to the developing of the seismic design standards. In this paper, the effects of masonry panels on the vibration response of an infilled steel-frame building are investigated. Various ambient and steady state forced vibration tests are carried out to realize the dynamic characteristics of the system. 3D finite element models of the building with and without infill panels are provided based on marcomodeling theorem. A set of analytical approximate formulas are also derived to estimate the vibrational period. The natural frequencies of the building are computed using numerical, analytical, and experimental methods. The results show that neglecting the effect of infill panels leads to considerable error. Moreover, it is shown that there is good agreement among the results obtained by the three methods considering the effect of infill panels.

  8. Analytical Methods for the Determination of Rosuvastatin in Pharmaceutical Formulations and Biological Fluids: A Critical Review.

    Science.gov (United States)

    Ângelo, Marilene Lopes; Moreira, Fernanda de Lima; Morais Ruela, André Luís; Santos, Ana Laura Araújo; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2018-07-04

    Rosuvastatin calcium (ROS), ( Figure 1 ) belongs to the "statins" group, which is the 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor. This drug is indicated for dyslipidemias treatment and can help to decrease the level of "bad cholesterol" and can consequently reduce the development of atherosclerosis and the risk of heart diseases. ROS was developed by Astra-Zeneca and it was approved in 2003 by the FDA in the United States. In 2015, under the trade name Crestor®, it was the fourth largest selling drug in the United States with sales above $5 billion. This study presents a literature review of analytical methods for the quantification of ROS in pharmaceutical preparations and biological fluids. The major analytical methods described in this study for ROS were spectrophotometry, high-performance liquid chromatography (HPLC) coupled to ultraviolet (UV) detection, and tandem mass spectrometry (LC-MS/MS).

  9. Environmental equity research: review with focus on outdoor air pollution research methods and analytic tools.

    Science.gov (United States)

    Miao, Qun; Chen, Dongmei; Buzzelli, Michael; Aronson, Kristan J

    2015-01-01

    The objective of this study was to review environmental equity research on outdoor air pollution and, specifically, methods and tools used in research, published in English, with the aim of recommending the best methods and analytic tools. English language publications from 2000 to 2012 were identified in Google Scholar, Ovid MEDLINE, and PubMed. Research methodologies and results were reviewed and potential deficiencies and knowledge gaps identified. The publications show that exposure to outdoor air pollution differs by social factors, but findings are inconsistent in Canada. In terms of study designs, most were small and ecological and therefore prone to the ecological fallacy. Newer tools such as geographic information systems, modeling, and biomarkers offer improved precision in exposure measurement. Higher-quality research using large, individual-based samples and more precise analytic tools are needed to provide better evidence for policy-making to reduce environmental inequities.

  10. Application of nuclear analytical methods to heavy metal pollution studies of estuaries

    International Nuclear Information System (INIS)

    Anders, B.; Junge, W.; Knoth, J.; Michaelis, W.; Pepelnik, R.; Schwenke, H.

    1984-01-01

    Important objectives of heavy metal pollution studies of estuaries are the understanding of the transport phenomena in these complex ecosystems and the discovery of the pollution history and the geochemical background. Such studies require high precision and accuracy of the analytical methods. Moreover, pronounced spatial heterogeneities and temporal variabilities that are typical for estuaries necessitate the analysis of a great number of samples if relevant results are to be obtained. Both requirements can economically be fulfilled by a proper combination of analytical methods. Applications of energy-dispersive X-ray fluorescence analysis with total reflection of the exciting beam at the sample support and of neutron activation analysis with both thermal and fast neutrons are reported in the light of pollution studies performed in the Lower Elbe River. (orig.)

  11. Abstracts book of 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements

    International Nuclear Information System (INIS)

    1995-01-01

    The 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements has been held in Poznan 27-28 April 1995. The new versions of analytical methods have been presented for quantitative determination of trace elements in biological, environmental and geological materials. Also the number of special techniques for sample preparation enables achievement the best precision of analytical results have been shown and discussed

  12. Results of an interlaboratory comparison of analytical methods for contaminants of emerging concern in water.

    Science.gov (United States)

    Vanderford, Brett J; Drewes, Jörg E; Eaton, Andrew; Guo, Yingbo C; Haghani, Ali; Hoppe-Jones, Christiane; Schluesener, Michael P; Snyder, Shane A; Ternes, Thomas; Wood, Curtis J

    2014-01-07

    An evaluation of existing analytical methods used to measure contaminants of emerging concern (CECs) was performed through an interlaboratory comparison involving 25 research and commercial laboratories. In total, 52 methods were used in the single-blind study to determine method accuracy and comparability for 22 target compounds, including pharmaceuticals, personal care products, and steroid hormones, all at ng/L levels in surface and drinking water. Method biases ranged from caffeine, NP, OP, and triclosan had false positive rates >15%. In addition, some methods reported false positives for 17β-estradiol and 17α-ethynylestradiol in unspiked drinking water and deionized water, respectively, at levels higher than published predicted no-effect concentrations for these compounds in the environment. False negative rates were also generally contamination, misinterpretation of background interferences, and/or inappropriate setting of detection/quantification levels for analysis at low ng/L levels. The results of both comparisons were collectively assessed to identify parameters that resulted in the best overall method performance. Liquid chromatography-tandem mass spectrometry coupled with the calibration technique of isotope dilution were able to accurately quantify most compounds with an average bias of <10% for both matrixes. These findings suggest that this method of analysis is suitable at environmentally relevant levels for most of the compounds studied. This work underscores the need for robust, standardized analytical methods for CECs to improve data quality, increase comparability between studies, and help reduce false positive and false negative rates.

  13. Selection bias in dynamically measured supermassive black hole samples: scaling relations and correlations between residuals in semi-analytic galaxy formation models

    Science.gov (United States)

    Barausse, Enrico; Shankar, Francesco; Bernardi, Mariangela; Dubois, Yohan; Sheth, Ravi K.

    2017-07-01

    Recent work has confirmed that the scaling relations between the masses of supermassive black holes and host-galaxy properties such as stellar masses and velocity dispersions may be biased high. Much of this may be caused by the requirement that the black hole sphere of influence must be resolved for the black hole mass to be reliably estimated. We revisit this issue with a comprehensive galaxy evolution semi-analytic model. Once tuned to reproduce the (mean) correlation of black hole mass with velocity dispersion, the model cannot account for the correlation with stellar mass. This is independent of the model's parameters, thus suggesting an internal inconsistency in the data. The predicted distributions, especially at the low-mass end, are also much broader than observed. However, if selection effects are included, the model's predictions tend to align with the observations. We also demonstrate that the correlations between the residuals of the scaling relations are more effective than the relations themselves at constraining models for the feedback of active galactic nuclei (AGNs). In fact, we find that our model, while in apparent broad agreement with the scaling relations when accounting for selection biases, yields very weak correlations between their residuals at fixed stellar mass, in stark contrast with observations. This problem persists when changing the AGN feedback strength, and is also present in the hydrodynamic cosmological simulation Horizon-AGN, which includes state-of-the-art treatments of AGN feedback. This suggests that current AGN feedback models are too weak or simply not capturing the effect of the black hole on the stellar velocity dispersion.

  14. Developing automated analytical methods for scientific environments using LabVIEW.

    Science.gov (United States)

    Wagner, Christoph; Armenta, Sergio; Lendl, Bernhard

    2010-01-15

    The development of new analytical techniques often requires the building of specially designed devices, each requiring its own dedicated control software. Especially in the research and development phase, LabVIEW has proven to be one highly useful tool for developing this software. Yet, it is still common practice to develop individual solutions for different instruments. In contrast to this, we present here a single LabVIEW-based program that can be directly applied to various analytical tasks without having to change the program code. Driven by a set of simple script commands, it can control a whole range of instruments, from valves and pumps to full-scale spectrometers. Fluid sample (pre-)treatment and separation procedures can thus be flexibly coupled to a wide range of analytical detection methods. Here, the capabilities of the program have been demonstrated by using it for the control of both a sequential injection analysis - capillary electrophoresis (SIA-CE) system with UV detection, and an analytical setup for studying the inhibition of enzymatic reactions using a SIA system with FTIR detection.

  15. Analytical Method of Malculation of the Current and Torque a Reluctance Stepper Motor via Fourier Series

    Directory of Open Access Journals (Sweden)

    Pavel Zaskalicky

    2008-01-01

    Full Text Available Reluctance stepper motors are becoming to be very attractive transducer to conversion of electric signal to the mechanical position. Due to its simple construction is reluctance machine considered a very reliable machine which not requiring any maintenance. Present paper proposes a mathematical method of an analytical calculus of a phase current and electromagnetic torque of the motor via Fourier series. Saturation effect and winding reluctance are neglected.

  16. Analytical Treatment of Higher-Order Graphs: A Path Ordinal Method for Solving Graphs

    Directory of Open Access Journals (Sweden)

    Hala Kamal

    2017-11-01

    Full Text Available Analytical treatment of the composition of higher-order graphs representing linear relations between variables is developed. A path formalism to deal with problems in graph theory is introduced. It is shown how paths in the composed graph representing individual contributions to variables relation can be enumerated and represented by ordinals. The method allows for one to extract partial information and gives an alternative to classical graph approach.

  17. Validation of the analytical method for sodium dichloroisocyanurate aimed at drinking water disinfection

    International Nuclear Information System (INIS)

    Martinez Alvarez, Luis Octavio; Alejo Cisneros, Pedro; Garcia Pereira, Reynaldo; Campos Valdez, Doraily

    2014-01-01

    Cuba has developed the first effervescent 3.5 mg sodium dichloroisocyanurate tablets as a non-therapeutic active principle. This ingredient releases certain amount of chlorine when dissolved into a litre of water and it can cause adequate disinfection of drinking water ready to be taken after 30 min. Developing and validating an analytical iodometric method applicable to the quality control of effervescent 3.5 mg sodium dichloroisocyanurate tablets

  18. CO2 Leakage, Storage and Injection Monitoring by Using Experimental, Numerical and Analytical Methods

    Directory of Open Access Journals (Sweden)

    A. Namdar

    2014-09-01

    Full Text Available The maintaining environment is priority to any plan in human life. It is planned for monitoring CO2 injection, storage and leakage by using geophysical, numerical and analytical methods in seismic zone. In this regard the mineralogy, chemical composite, lithology, seismic wave propagation, small earthquake, accelerating natural earthquake, thermal stress-strain modeling, ground movement level and fault activation will be consider. It is expected to better understand CO2 leakage, storage and injection process and problems.

  19. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  20. Analytical Method Used to Calculate Pile Foundations with the Widening Up on a Horizontal Static Impact

    Science.gov (United States)

    Kupchikova, N. V.; Kurbatskiy, E. N.

    2017-11-01

    This paper presents a methodology for the analytical research solutions for the work pile foundations with surface broadening and inclined side faces in the ground array, based on the properties of Fourier transform of finite functions. The comparative analysis of the calculation results using the suggested method for prismatic piles, piles with surface broadening prismatic with precast piles and end walls with precast wedges on the surface is described.