WorldWideScience

Sample records for residual risk measure

  1. RESIDUAL RISK ASSESSMENT: ETHYLENE OXIDE ...

    Science.gov (United States)

    This document describes the residual risk assessment for the Ethylene Oxide Commercial Sterilization source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Ethylene Oxide Commercial Sterilization source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  2. Research items regarding seismic residual risk evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    After learning the Fukushima Dai-ichi NPP severe accidents in 2011, the government investigation committee proposed the effective use of probabilistic safety assessment (PSA), and now it is required to establish new safety rules reflecting the results of probabilistic risk assessment (PRA) and proposed severe accident measures. Since the Seismic Design Guide has been revised on September 19, 2006, JNES has been discussing seismic PRA (Levels 1-3) methods to review licensees' residual risk assessment while preparing seismic PRA models. Meanwhile, new safety standards for light water reactors are to be issued and enforced on July 2013, which require the residual risk of tsunami, in addition to earthquakes, should be lowered as much as possible. The Fukushima accidents raised the problems related to risk assessment, e.g. approaches based on multi-hazard (earthquake and tsunami), multi-unit, multi-site, and equipment's common cause failure. This fiscal year, while performing seismic and/or tsunami PRA to work on these problems, JNES picked up the equipment whose failure greatly contribute to core damage, surveyed accident management measures on those equipment as well as effectiveness to reduce core damage probability. (author)

  3. Pesticide residues and bees--a risk assessment.

    Directory of Open Access Journals (Sweden)

    Francisco Sanchez-Bayo

    Full Text Available Bees are essential pollinators of many plants in natural ecosystems and agricultural crops alike. In recent years the decline and disappearance of bee species in the wild and the collapse of honey bee colonies have concerned ecologists and apiculturalists, who search for causes and solutions to this problem. Whilst biological factors such as viral diseases, mite and parasite infections are undoubtedly involved, it is also evident that pesticides applied to agricultural crops have a negative impact on bees. Most risk assessments have focused on direct acute exposure of bees to agrochemicals from spray drift. However, the large number of pesticide residues found in pollen and honey demand a thorough evaluation of all residual compounds so as to identify those of highest risk to bees. Using data from recent residue surveys and toxicity of pesticides to honey and bumble bees, a comprehensive evaluation of risks under current exposure conditions is presented here. Standard risk assessments are complemented with new approaches that take into account time-cumulative effects over time, especially with dietary exposures. Whilst overall risks appear to be low, our analysis indicates that residues of pyrethroid and neonicotinoid insecticides pose the highest risk by contact exposure of bees with contaminated pollen. However, the synergism of ergosterol inhibiting fungicides with those two classes of insecticides results in much higher risks in spite of the low prevalence of their combined residues. Risks by ingestion of contaminated pollen and honey are of some concern for systemic insecticides, particularly imidacloprid and thiamethoxam, chlorpyrifos and the mixtures of cyhalothrin and ergosterol inhibiting fungicides. More attention should be paid to specific residue mixtures that may result in synergistic toxicity to bees.

  4. Residual-stress measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ezeilo, A N; Webster, G A [Imperial College, London (United Kingdom); Webster, P J [Salford Univ. (United Kingdom)

    1997-04-01

    Because neutrons can penetrate distances of up to 50 mm in most engineering materials, this makes them unique for establishing residual-stress distributions non-destructively. D1A is particularly suited for through-surface measurements as it does not suffer from instrumental surface aberrations commonly found on multidetector instruments, while D20 is best for fast internal-strain scanning. Two examples for residual-stress measurements in a shot-peened material, and in a weld are presented to demonstrate the attractive features of both instruments. (author).

  5. Pesticide Residues and Bees – A Risk Assessment

    Science.gov (United States)

    Sanchez-Bayo, Francisco; Goka, Koichi

    2014-01-01

    Bees are essential pollinators of many plants in natural ecosystems and agricultural crops alike. In recent years the decline and disappearance of bee species in the wild and the collapse of honey bee colonies have concerned ecologists and apiculturalists, who search for causes and solutions to this problem. Whilst biological factors such as viral diseases, mite and parasite infections are undoubtedly involved, it is also evident that pesticides applied to agricultural crops have a negative impact on bees. Most risk assessments have focused on direct acute exposure of bees to agrochemicals from spray drift. However, the large number of pesticide residues found in pollen and honey demand a thorough evaluation of all residual compounds so as to identify those of highest risk to bees. Using data from recent residue surveys and toxicity of pesticides to honey and bumble bees, a comprehensive evaluation of risks under current exposure conditions is presented here. Standard risk assessments are complemented with new approaches that take into account time-cumulative effects over time, especially with dietary exposures. Whilst overall risks appear to be low, our analysis indicates that residues of pyrethroid and neonicotinoid insecticides pose the highest risk by contact exposure of bees with contaminated pollen. However, the synergism of ergosterol inhibiting fungicides with those two classes of insecticides results in much higher risks in spite of the low prevalence of their combined residues. Risks by ingestion of contaminated pollen and honey are of some concern for systemic insecticides, particularly imidacloprid and thiamethoxam, chlorpyrifos and the mixtures of cyhalothrin and ergosterol inhibiting fungicides. More attention should be paid to specific residue mixtures that may result in synergistic toxicity to bees. PMID:24718419

  6. Recent advances in residual stress measurement

    International Nuclear Information System (INIS)

    Withers, P.J.; Turski, M.; Edwards, L.; Bouchard, P.J.; Buttle, D.J.

    2008-01-01

    Until recently residual stresses have been included in structural integrity assessments of nuclear pressure vessels and piping in a very primitive manner due to the lack of reliable residual stress measurement or prediction tools. This situation is changing the capabilities of newly emerging destructive (i.e. the contour method) and non-destructive (i.e. magnetic and high-energy synchrotron X-ray strain mapping) residual stress measurement techniques for evaluating ferritic and austenitic pressure vessel components are contrasted against more well-established methods. These new approaches offer the potential for obtaining area maps of residual stress or strain in welded plants, mock-up components or generic test-pieces. The mapped field may be used directly in structural integrity calculations, or indirectly to validate finite element process/structural models on which safety cases for pressurised nuclear systems are founded. These measurement methods are complementary in terms of application to actual plant, cost effectiveness and measurements in thick sections. In each case an exemplar case study is used to illustrate the method and to highlight its particular capabilities

  7. Drug residues in urban water: A database for ecotoxicological risk management.

    Science.gov (United States)

    Destrieux, Doriane; Laurent, François; Budzinski, Hélène; Pedelucq, Julie; Vervier, Philippe; Gerino, Magali

    2017-12-31

    Human-use drug residues (DR) are only partially eliminated by waste water treatment plants (WWTPs), so that residual amounts can reach natural waters and cause environmental hazards. In order to properly manage these hazards in the aquatic environment, a database is made available that integrates the concentration ranges for DR, which cause adverse effects for aquatic organisms, and the temporal variations of the ecotoxicological risks. To implement this database for the ecotoxicological risk assessment (ERA database), the required information for each DR is the predicted no effect concentrations (PNECs), along with the predicted environmental concentrations (PECs). The risk assessment is based on the ratio between the PNECs and the PECs. Adverse effect data or PNECs have been found in the publicly available literature for 45 substances. These ecotoxicity test data have been extracted from 125 different sources. This ERA database contains 1157 adverse effect data and 287 PNECs. The efficiency of this ERA database was tested with a data set coming from a simultaneous survey of WWTPs and the natural environment. In this data set, 26 DR were searched for in two WWTPs and in the river. On five sampling dates, concentrations measured in the river for 10 DR could pose environmental problems of which 7 were measured only downstream of WWTP outlets. From scientific literature and measurements, data implementation with unit homogenisation in a single database facilitates the actual ecotoxicological risk assessment, and may be useful for further risk coming from data arising from the future field survey. Moreover, the accumulation of a large ecotoxicity data set in a single database should not only improve knowledge of higher risk molecules but also supply an objective tool to help the rapid and efficient evaluation of the risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  9. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2000-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed

  10. Measurement of residual stresses using fracture mechanics weight functions

    International Nuclear Information System (INIS)

    Fan, Y.

    2001-01-01

    A residual stress measurement method has been developed to quantify through-the-thickness residual stresses. Accurate measurement of residual stresses is crucial for many engineering structures. Fabrication processes such as welding and machining generate residual stresses that are difficult to predict. Residual stresses affect the integrity of structures through promoting failures due to brittle fracture, fatigue, stress corrosion cracking, and wear. In this work, the weight function theory of fracture mechanics is used to measure residual stresses. The weight function theory is an important development in computational fracture mechanics. Stress intensity factors for arbitrary stress distribution on the crack faces can be accurately and efficiently computed for predicting crack growth. This paper demonstrates that the weight functions are equally useful in measuring residual stresses. In this method, an artificial crack is created by a thin cut in a structure containing residual stresses. The cut relieves the residual stresses normal to the crack-face and allows the relieved residual stresses to deform the structure. Strain gages placed adjacent to the cut measure the relieved strains corresponding to incrementally increasing depths of the cut. The weight functions of the cracked body relate the measured strains to the residual stresses normal to the cut within the structure. The procedure details, such as numerical integration of the singular functions in applying the weight function method, will be discussed. (author)

  11. Neutron residual stress measurements in linepipe

    International Nuclear Information System (INIS)

    Law, Michael; Gnaepel-Herold, Thomas; Luzin, Vladimir; Bowie, Graham

    2006-01-01

    Residual stresses in gas pipelines are generated by manufacturing and construction processes and may affect the subsequent pipe integrity. In the present work, the residual stresses in eight samples of linepipe were measured by neutron diffraction. Residual stresses changed with some coating processes. This has special implications in understanding and mitigating stress corrosion cracking, a major safety and economic problem in some gas pipelines

  12. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  13. X-ray measurement of residual stress on bolt threads

    International Nuclear Information System (INIS)

    Hagiwara, Masaya; Nakahara, Kanefumi; Yoshimoto, Isamu.

    1989-01-01

    This study deals with X-ray measurement of residual stress at the local area around the thread root of a bolt. Residual stress in the 0.5 mm x 5 mm area was measured using a method of stepped scanning and parabolic approximation. The conditions of measurement had been determined and evaluated through the preliminary measurement of compressive stress acting on the cylindrical surface. Furthermore, the fatigue strength estimated by applying the residual stress data to the previously presented hypothesis was compared with the experimental results. The main conclusions obtained were as follows: (1) The residual stress in a relatively small area on the cylindrical surface with large curvature can be measured by X-ray using a method of stepped scanning and parabolic approximation; (2) The compressive residual stress measured at the thread root was larger for the bolt manufactured by thread rolling after heat treatment than for one manufactured by thread rolling before heat treatment; (3) The distribution of residual stress along the axial direction from the thread root to the portion under crest did not represent remarkable change in its value; (4) The residual stress of a bolt was somewhat decreased by fatigue loading on the condition of low mean stress; (5) The fatigue strength estimated using residual stress data showed the tendency of experimental results well. (author)

  14. Properties of Risk Measures of Generalized Entropy in Portfolio Selection

    Directory of Open Access Journals (Sweden)

    Rongxi Zhou

    2017-12-01

    Full Text Available This paper systematically investigates the properties of six kinds of entropy-based risk measures: Information Entropy and Cumulative Residual Entropy in the probability space, Fuzzy Entropy, Credibility Entropy and Sine Entropy in the fuzzy space, and Hybrid Entropy in the hybridized uncertainty of both fuzziness and randomness. We discover that none of the risk measures satisfy all six of the following properties, which various scholars have associated with effective risk measures: Monotonicity, Translation Invariance, Sub-additivity, Positive Homogeneity, Consistency and Convexity. Measures based on Fuzzy Entropy, Credibility Entropy, and Sine Entropy all exhibit the same properties: Sub-additivity, Positive Homogeneity, Consistency, and Convexity. These measures based on Information Entropy and Hybrid Entropy, meanwhile, only exhibit Sub-additivity and Consistency. Cumulative Residual Entropy satisfies just Sub-additivity, Positive Homogeneity, and Convexity. After identifying these properties, we develop seven portfolio models based on different risk measures and made empirical comparisons using samples from both the Shenzhen Stock Exchange of China and the New York Stock Exchange of America. The comparisons show that the Mean Fuzzy Entropy Model performs the best among the seven models with respect to both daily returns and relative cumulative returns. Overall, these results could provide an important reference for both constructing effective risk measures and rationally selecting the appropriate risk measure under different portfolio selection conditions.

  15. Ultrasonic measurements on residual stress in autofrettged thick walled petroleum pipes

    International Nuclear Information System (INIS)

    Woias, G.; Mizera, J.

    2008-01-01

    optimal specimen length as 60 mm required beam time is for three slices measurements in depth of wall. This work is to compare the neutron stresses on ultrasound technique and FEM. Results of FEM modeling shows the axial compression zone in the inner side of the pipe. The residual stresses are growing while the pipe is in exploitation. Non-destructive method of measurements - ultrasonic - will be the best way of life time assessment and degradation monitoring. That's why the results obtained with other residual stresses measuring methods are significant. The measurements using neutron gauge are planned to be done on the inner surface of the pipe. According to the FEM model the dimensions of the sample to rule out any risk of residual stresses relaxation are described in inferences by FEM analysis. To assess residual stresses with 5% accuracy it is required to measure slice cut samples not less that two pipe's thickness length - 60 cm. Three samples were prepared to be measured: 1) New pipe after autofrettaging [Np]; 2) Pipe after exploitation from the upper part of the reactor - heating zone [11/1]; 3) Pipe from lower part - cooling zone [75]. In the first part of the experiment, the pipe no [11/1] has been measured for axial and hoop stresses. The pipe [Np] was measured for axial stresses. The aim of these measurements will be measuring hoop residual stress on a non-used pipe after autofrettaging [Np] as well as hoop and axial stresses in a pipe taken from the lower part of the reactor - the cooling zone. (author)

  16. Residual and Destroyed Accessible Information after Measurements

    Science.gov (United States)

    Han, Rui; Leuchs, Gerd; Grassl, Markus

    2018-04-01

    When quantum states are used to send classical information, the receiver performs a measurement on the signal states. The amount of information extracted is often not optimal due to the receiver's measurement scheme and experimental apparatus. For quantum nondemolition measurements, there is potentially some residual information in the postmeasurement state, while part of the information has been extracted and the rest is destroyed. Here, we propose a framework to characterize a quantum measurement by how much information it extracts and destroys, and how much information it leaves in the residual postmeasurement state. The concept is illustrated for several receivers discriminating coherent states.

  17. Organic amendments for risk mitigation of organochlorine pesticide residues in old orchard soils

    International Nuclear Information System (INIS)

    Centofanti, Tiziana; McConnell, Laura L.; Chaney, Rufus L.; Beyer, W. Nelson; Andrade, Natasha A.; Hapeman, Cathleen J.; Torrents, Alba; Nguyen, Anh; Anderson, Marya O.; Novak, Jeffrey M.

    2016-01-01

    Performance of compost and biochar amendments for in situ risk mitigation of aged DDT, DDE and dieldrin residues in an old orchard soil was examined. The change in bioavailability of pesticide residues to Lumbricus terrestris L. relative to the unamended control soil was assessed using 4-L soil microcosms with and without plant cover in a 48-day experiment. The use of aged dairy manure compost and biosolids compost was found to be effective, especially in the planted treatments, at lowering the bioavailability factor (BAF) by 18–39%; however, BAF results for DDT in the unplanted soil treatments were unaffected or increased. The pine chip biochar utilized in this experiment was ineffective at lower the BAF of pesticides in the soil. The US EPA Soil Screening Level approach was used with our measured values. Addition of 10% of the aged dairy manure compost reduced the average hazard quotient values to below 1.0 for DDT + DDE and dieldrin. Results indicate this sustainable approach is appropriate to minimize risks to wildlife in areas of marginal organochlorine pesticide contamination. Application of this remediation approach has potential for use internationally in areas where historical pesticide contamination of soils remains a threat to wildlife populations. - Highlights: • Historical applications of organochlorine pesticides are a risk to local ecosystems. • Low cost and sustainable mitigation measures are needed to reduce risks. • Organic matter rich amendments were added to contaminated soil. • Earthworms microcosms were used to measure bioaccumulation factors. • Aged composts were most effective at mitigating risks to ecosystems. - Incorporation of aged dairy manure and biosolids compost amendments is an effective, low cost approach to mitigate risks to terrestrial wildlife from organochlorine pesticides in soils.

  18. Residual stress measurement in a metal microdevice by micro Raman spectroscopy

    International Nuclear Information System (INIS)

    Song, Chang; Du, Liqun; Qi, Leijie; Li, Yu; Li, Xiaojun; Li, Yuanqi

    2017-01-01

    Large residual stress induced during the electroforming process cannot be ignored to fabricate reliable metal microdevices. Accurate measurement is the basis for studying the residual stress. Influenced by the topological feature size of micron scale in the metal microdevice, residual stress in it can hardly be measured by common methods. In this manuscript, a methodology is proposed to measure the residual stress in the metal microdevice using micro Raman spectroscopy (MRS). To estimate the residual stress in metal materials, micron sized β -SiC particles were mixed in the electroforming solution for codeposition. First, the calculated expression relating the Raman shifts to the induced biaxial stress for β -SiC was derived based on the theory of phonon deformation potentials and Hooke’s law. Corresponding micro electroforming experiments were performed and the residual stress in Ni–SiC composite layer was both measured by x-ray diffraction (XRD) and MRS methods. Then, the validity of the MRS measurements was verified by comparing with the residual stress measured by XRD method. The reliability of the MRS method was further validated by the statistical student’s t -test. The MRS measurements were found to have no systematic error in comparison with the XRD measurements, which confirm that the residual stresses measured by the MRS method are reliable. Besides that, the MRS method, by which the residual stress in a micro inertial switch was measured, has been confirmed to be a convincing experiment tool for estimating the residual stress in metal microdevice with micron order topological feature size. (paper)

  19. Residual stress measurement in a metal microdevice by micro Raman spectroscopy

    Science.gov (United States)

    Song, Chang; Du, Liqun; Qi, Leijie; Li, Yu; Li, Xiaojun; Li, Yuanqi

    2017-10-01

    Large residual stress induced during the electroforming process cannot be ignored to fabricate reliable metal microdevices. Accurate measurement is the basis for studying the residual stress. Influenced by the topological feature size of micron scale in the metal microdevice, residual stress in it can hardly be measured by common methods. In this manuscript, a methodology is proposed to measure the residual stress in the metal microdevice using micro Raman spectroscopy (MRS). To estimate the residual stress in metal materials, micron sized β-SiC particles were mixed in the electroforming solution for codeposition. First, the calculated expression relating the Raman shifts to the induced biaxial stress for β-SiC was derived based on the theory of phonon deformation potentials and Hooke’s law. Corresponding micro electroforming experiments were performed and the residual stress in Ni-SiC composite layer was both measured by x-ray diffraction (XRD) and MRS methods. Then, the validity of the MRS measurements was verified by comparing with the residual stress measured by XRD method. The reliability of the MRS method was further validated by the statistical student’s t-test. The MRS measurements were found to have no systematic error in comparison with the XRD measurements, which confirm that the residual stresses measured by the MRS method are reliable. Besides that, the MRS method, by which the residual stress in a micro inertial switch was measured, has been confirmed to be a convincing experiment tool for estimating the residual stress in metal microdevice with micron order topological feature size.

  20. Food toxicology. Residues and contaminants: Risks and consumer protection; Lebensmitteltoxikologie. Rueckstaende und Kontaminanten: Risiken und Verbraucherschutz

    Energy Technology Data Exchange (ETDEWEB)

    Nau, H. [Tieraerztliche Hochschule Hannover, ZA Lebensmitteltoxikologie (Germany); Steinberg, P. [Potsdam Univ., Inst. fuer Ernaehrungswissenschaft (Germany); Kietzmann, M. (eds.) [Tieraerztliche Hochschule Hannover, Inst. fuer Pharmakologie, Toxikologie/Pharmazie (Germany)

    2003-07-01

    In a detailed introduction, the basic methods of risk assessment for potentially toxic food constituents are presented as well as the analytical methods applied for measuring even very small concentrations of contaminants. The main classes of substances relevant in foods ar represented, i.e. animal drugs, fungicides and herbicides, natural toxins, contaminants, prions from BSE-infested animals and residues of 'new' proteins and 'new' DNA from genetically modified foods. New legislation in Germany and Europe is presented including the National Residue Monitoring Plant which is to enable annual monitoring of residue concentrations in foods derived from animals. (orig.)

  1. Residual stress measurement with focused acoustic waves and direct comparison with X-ray diffraction stress measurements

    International Nuclear Information System (INIS)

    Sathish, Shamachary; Moran, Thomas J.; Martin, Richard W.; Reibel, Richard

    2005-01-01

    The technique of measuring small changes in acoustic wave velocity due to external or internal stress has been used for quantitative determination of residual stress in materials during the last decade. Application of similar methodology with focused acoustic waves leads to residual stress measurement with spatial resolution of a few millimeters to a few microns. The high spatial resolution residual stress measurement required development of new methodologies in both the design of acoustic lenses and the instrumentation for acoustic wave velocity determination. This paper presents two new methodologies developed for the measurement of residual stress with spatial resolution of a few millimeters. The design of new type of acoustic lens for achieving higher spatial resolution in residual stress measurement is introduced. Development of instrumentation for high precision local surface wave velocity measurement will be presented. Residual stresses measured around a crack tip in a sample of Ti-6A1-4V using a focused beam will be compared with X-ray diffraction measurements performed on the same region of the sample. Results of residual stress measurements along a direction perpendicular to the electron beam weld in a sample of Ti-6A1-4V, determined using focused acoustic waves and X-ray diffraction technique, are also presented. The spatial resolution and penetration depth of X-rays and focused acoustic beams with reference to residual stress measurements are discussed

  2. Construction of a risk assessment system for chemical residues in agricultural products.

    Science.gov (United States)

    Choi, Shinai; Hong, Jiyeon; Lee, Dayeon; Paik, Minkyoung

    2014-01-01

    Continuous monitoring of chemical residues in agricultural and food products has been performed by various government bodies in South Korea. These bodies have made attempts to systematically manage this information by creating a monitoring database system as well as a system based on these data with which to assess the health risk of chemical residues in agricultural products. Meanwhile, a database system is being constructed consisting of information about monitoring and, following this, a demand for convenience has led to the need for an evaluation tool to be constructed with the data processing system. Also, in order to create a systematic and effective tool for the risk assessment of chemical residues in foods and agricultural products, various evaluation models are being developed, both domestically and abroad. Overseas, systems such as Dietary Exposure Evaluation Model: Food Commodity Intake Database and Cumulative and Aggregate Risk Evaluation System are being used; these use the US Environmental Protection Agency as a focus, while the EU has developed Pesticide Residue Intake Model for assessments of pesticide exposure through food intake. Following this, the National Academy of Agricultural Science (NAAS) created the Agricultural Products Risk Assessment System (APRAS) which supports the use and storage of monitoring information and risk assessments. APRAS efficiently manages the monitoring data produced by NAAS and creates an extraction feature included in the database system. Also, the database system in APRAS consists of a monitoring database system held by the NAAS and food consumption database system. Food consumption data is based on Korea National Health and Nutrition Examination Survey. This system is aimed at exposure and risk assessments for chemical residues in agricultural products with regards to different exposure scenarios.

  3. Human health risks associated with residual pesticide levels in edible tissues of slaughtered cattle in Benin City, Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Isioma Tongo

    2015-01-01

    Full Text Available Pesticide residues in meat is of growing concern due to possible adverse effects on humans. Pesticide levels were assessed in five edible cattle parts: muscle, liver, kidney and tongue tissues to determine human health risk associated with consumption of these tissues. Health risk estimates were analysed using estimated daily intake (EDI, hazard quotient (HQ and hazard index (HI for two (2 age/weight categories: 1–11years/30 kg for children while 70 kg was used for adult. Risks were categorized for non-carcinogenic and carcinogenic health effects and measured at the average, maximum, 50th and 95th percentiles of the measured exposure concentrations (MEC. Total pesticide residues ranged from 2.38 to 3.86 μg/kg (muscle, 3.58 to 6.3 μg/kg (liver, 1.87 to 4.59 μg/kg (kidney and 2.54 to 4.35 μg/kg (tongue. Residual pesticide concentrations in the tissues were in the order: Liver > Tongue > Muscle > Kidney. The concentrations of all the assessed pesticides observed in the tissues were however lower than the recommended maximum residual limits (MRLs. Human health risk estimations for the children showed EDI values for heptachlor epoxide, aldrin and dieldrin exceeding threshold values. Non-cancer risk posed to children on consumption of contaminated cattle parts showed HQ values for heptachlor epoxide, aldrin, dieldrin and HI values for organochlorines exceeding 1, indicating the possibility of non-carcinogenic health risks to consumers especially children from consumption of cattle meat from the selected abattoirs.

  4. Measuring depth profiles of residual stress with Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Enloe, W.S.; Sparks, R.G.; Paesler, M.A.

    1988-12-01

    Knowledge of the variation of residual stress is a very important factor in understanding the properties of machined surfaces. The nature of the residual stress can determine a part`s susceptibility to wear deformation, and cracking. Raman spectroscopy is known to be a very useful technique for measuring residual stress in many materials. These measurements are routinely made with a lateral resolution of 1{mu}m and an accuracy of 0.1 kbar. The variation of stress with depth; however, has not received much attention in the past. A novel technique has been developed that allows quantitative measurement of the variation of the residual stress with depth with an accuracy of 10nm in the z direction. Qualitative techniques for determining whether the stress is varying with depth are presented. It is also demonstrated that when the stress is changing over the volume sampled, errors can be introduced if the variation of the stress with depth is ignored. Computer aided data analysis is used to determine the depth dependence of the residual stress.

  5. Optical residual stress measurement in TFT-LCD panels

    Science.gov (United States)

    Wang, Wei-Chung; Sung, Po-Chi

    2017-06-01

    The residual stress of the glass substrate might be one of causes to produce the non-uniform light distribution defect, i.e. Mura, in thin film transistor-liquid crystal display (TFT-LCD) panels. Glass is a birefringent material with very low birefringence. Furthermore, the thinner and thinner thickness request from the market makes the traditional photoelasticity almost impossible to measure the residual stresses produced in thin glass plates. Recently, a low-level stress measurement method called transmissivity extremities theory of photoelasticity (TEToP) was successfully developed to measure the residual stress in glass plate. Besides, to measure the stress of the glass plate in the TFT-LCD panel whose rear surface may has different kinds of coatings, an advanced reflection photoelasticity was also developed. In this paper, three commercially available glass plates with 0.33mm nominal thickness and three glass circular disks with different coatings were inspected to verify the feasibility of the TEToP and the advanced reflection photoelasticity, respectively.

  6. The method for measuring residual stress in stainless steel pipes

    International Nuclear Information System (INIS)

    Shimov, Georgy; Rozenbaum, Mikhail; Serebryakov, Alexandr; Serebryakov, Andrey

    2016-01-01

    The main reason of appearance and growth of corrosion damages of the nuclear steam generator heat exchanger tubes is the process of stress-corrosion cracking of metal under the influence of residual tensile stress. Methods used in the production for estimating residual stresses (such as a method of ring samples) allow measuring only the average tangential stress of the pipe wall. The method of ring samples does not allow to assess the level of residual stress in the surface layer of the pipe. This paper describes an experimental method for measuring the residual stresses on the pipe surface by etching a thin surface layer of the metal. The construction and working principle of a trial installation are described. The residual stresses in the wall of the tubes 16 × 1.5 mm (steel AISI 321) for nuclear steam generators is calculated. Keywords: heat exchange pipes, stress corrosion cracking, residual stresses, stress distribution, stress measurement.

  7. Residue levels and risk assessment of pesticides in nuts of China.

    Science.gov (United States)

    Liu, Yihua; Shen, Danyu; Li, Shiliang; Ni, Zhanglin; Ding, Ming; Ye, Caifen; Tang, Fubin

    2016-02-01

    The pesticide residue levels of three nuts (chestnut, walnut, pinenut) collected from seven main producing areas of China were investigated. Twenty-nine pesticides, including organophosphates (OPs), organochlorines (OCs), pyrethroids (PYs) and two fungicides (triadimefon and buprofezin) were analyzed by gas chromatography (GC). Four OPs (acephate, dimethoate, chlorpyrifos and parathion-methyl) were found in 11.4% samples, with the concentrations of 19.0 µg kg(-1) to 74.0 µg kg(-1). Six OCs (DDT, HCH, endosulfan, quintozene, aldrin and dieldrin) were found in 18.2% samples, with the concentrations of 2.0 µg kg(-1) to 65.7 µg kg(-1). Among OCs, p,p-DDE and α-HCH were the dominant isomer for DDT and HCH. Five PYs (fenpropathrin, fenvalerate, cypermethrin, bifenthrin and cyhalothrin) were found in 15.9% samples, with the concentrations of 2.5 µg kg(-1) to 433.0 µg kg(-1). Fenpropathrin was the most frequently detected pesticide. In addition, triadimefon and buprofezin were detected only in two samples. For the tested nuts, 25.0% samples with multiple residues (containing more than two pesticides) were noted, even up to 9.1% samples with five pesticide residues. The residue of 15.9% samples was higher than the maximum residue limits (MRLs) of China. The short-term risks for the tested nuts were below 1.2%, and the highest long-term risk was 12.58%. The cumulative risk (cHI) for the tested pesticides were 8.43% (OPs), 0.42% (OCs), 12.82% (PYs) and 0.15% (fungicides), respectively. The total cHI was 21.82%. There was no significant health risk for consumers via nuts consumption. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Treatment methods and comparative risks of thorium removal from waste residues

    International Nuclear Information System (INIS)

    Porter, R.D.; Hamby, D.M.; Martin, J.E.

    1997-07-01

    This study was done to examine the risks of remediation and the effectiveness of removal methods for thorium and its associated radioactive decay products from various soils and wastes associated with DOE's Formerly Utilized Sites Remedial Action Program (FUSRAP). Removal of 230 Th from uranium process residues would significantly reduce the buildup of 226 Ra (half-life of 1600 years), and since 230 Th concentrations at most of the important sites greatly exceed the 226 Ra concentrations, such removal would reduce the accumulation of additional radiation risks associated with 226 Ra and its products; and, if treatment also removed 226 Ra, these risks could be mitigated even further. Removal of 232 Th from thorium process residues would remove the source material for 228 Ra, and since 228 Ra has a half-life of 5.76 years, its control at FUSRAP sites could be done with land use controls for the 30--50 years required for 228 Ra and the risks associated with its decay products to decay away. It must be recognized, however, that treatment methods invariably require workers to process residues and waste materials usually with bulk handling techniques. These processes expose workers to the radioactivity in the materials, therefore, workers would incur radiological risks in addition to industrial accident risks. An important question is whether the potential reduction of future radiological risks to members of the public justifies the risks that are incurred by remediation workers due to handling materials. This study examines, first, the effectiveness of treatment and then the risks that would be associated with remediation

  9. Incidence and Residual Risk of HIV, HBV and HCV Infections Among Blood Donors in Tehran.

    Science.gov (United States)

    Saber, Hamid Reza; Tabatabaee, Seyed Morteza; Abasian, Ali; Jamali, Mostafa; SalekMoghadam, Ebadollah; Hajibeigi, Bashir; Alavian, Seyed Moayed; Mirrezaie, Seyed Mohammad

    2017-09-01

    Estimation of residual risk is essential to monitor and improve blood safety. Our epidemiologic knowledge in the Iranian donor population regarding transfusion transmitted viral infections (TTIs), is confined to a few studies based on prevalence rate. There are no reports on residual risk of TTIs in Iran. In present survey, a software database of donor records of Tehran Blood Transfusion Center (TBTC) was used to estimate the incidence and residual risk of hepatitis B virus (HBV), hepatitis C virus (HCV) and human immunodeficiency virus (HIV) infections, by applying the incidence rate/window period (IR-WP) model. A total of 1,207,155 repeat donations was included in the analysis and represented a mean of 8.4 donations per donor over 6 years. The incidence amongst repeat donors was estimated by dividing the number of confirmed seroconverting donors by the total number of person-years at risk. The residual risk was calculated using the incidence/window period model. Incidence rate and residual risk for HBV, HCV and HIV infections were calculated for total (2005-2010) and two consecutive periods (2005-2007 and 2008-2010) of the study. According to the IR-WP model, overall residual risk for HIV and HCV in the total study period was 0.4 and 12.5 per million units, respectively and for HBV 4.57/100,000 donations. The incidence and residual risk of TTIs, calculated on TBTC's blood supply was low and comparable with developed countries for HIV infection but high for HCV and HBV infections. Blood safety may therefore be better managed by applying other techniques like nucleic acid amplification tests.

  10. Treatment methods and comparative risks of thorium removal from waste residues

    Energy Technology Data Exchange (ETDEWEB)

    Porter, R.D.; Hamby, D.M.; Martin, J.E.

    1997-07-01

    This study was done to examine the risks of remediation and the effectiveness of removal methods for thorium and its associated radioactive decay products from various soils and wastes associated with DOE`s Formerly Utilized Sites Remedial Action Program (FUSRAP). Removal of {sup 230}Th from uranium process residues would significantly reduce the buildup of {sup 226}Ra (half-life of 1600 years), and since {sup 230}Th concentrations at most of the important sites greatly exceed the {sup 226}Ra concentrations, such removal would reduce the accumulation of additional radiation risks associated with {sup 226}Ra and its products; and, if treatment also removed {sup 226}Ra, these risks could be mitigated even further. Removal of {sup 232}Th from thorium process residues would remove the source material for {sup 228}Ra, and since {sup 228}Ra has a half-life of 5.76 years, its control at FUSRAP sites could be done with land use controls for the 30--50 years required for {sup 228}Ra and the risks associated with its decay products to decay away. It must be recognized, however, that treatment methods invariably require workers to process residues and waste materials usually with bulk handling techniques. These processes expose workers to the radioactivity in the materials, therefore, workers would incur radiological risks in addition to industrial accident risks. An important question is whether the potential reduction of future radiological risks to members of the public justifies the risks that are incurred by remediation workers due to handling materials. This study examines, first, the effectiveness of treatment and then the risks that would be associated with remediation.

  11. Measurement of residual stress in textured Al alloy by neutron diffraction method

    International Nuclear Information System (INIS)

    Okido, S.; Hayashi, M.; Tanaka, K.; Akiniwa, Y.; Minakawa, N.; Morii, Y.

    1999-01-01

    Residual stress generated in a shrunken aluminum alloy specimen, which was prepared for the round robin test conducted by VAMAS (Versailles Project on Advanced Materials and Standards) TWA-20 organized for the purpose of standardizing residual stress measurement methods, was evaluated by a neutron diffraction method. The main purpose of the round robin test was to assess the reproducibility of data obtained with the measurement facilities of the participants. The general standard of the Residual Stress Analyzer (RESA) constructed in the Japan Atomic Energy Research Institute was verified from the measured residual strains, which were equivalent to the values calculated by FEM and values measured by the research facilities in North America. Residual stress was calculated from residual strain in three perpendicular directions. The diffraction intensities were dependent on measurement directions since the prepared specimen possessed texture. Diffraction profiles in directions having a weak diffraction intensity caused an inaccurate evaluation of the residual stress. To solve this problem, a new method for evaluating residual stress with respect to diffraction plane dependency of the elastic constant was applied. The diffraction plane giving the highest intensity among 110, 200, and 220 diffraction was used to evaluate the residual strain in each of three directions. The residual strain obtained on the used diffraction plane was converted to the equivalent strain for the defined diffraction plane using the ratio of elastic constants of these two planes. The developed evaluation method achieved highly accurate measurement and remarkable efficiency in the measurement process. (author)

  12. A Study on Residual Stress Measurements by Using Laser Speckle Interferometry

    International Nuclear Information System (INIS)

    Rho, Kyung Wan; Kang, Young June; Hong, Seong Jin; Kang, Hyung Soo

    1999-01-01

    Residual stress is one of the causes which make defects in engineering components and materials. And interest in the measurement of residual stress exists in many industries. There are commonly used methods by which residual stresses are currently measured. But these methods have a little demerits: time consumption and other problems. Therefore we devised a new experimental technique to measure residual stress in materials with a combination of laser speckle pattern interferometry, finite element method and spot heating. The speckle pattern interferometer measures in-plane deformations while the heating provides for very localized stress relief. FEM is used for determining heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heating and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method

  13. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  14. The measurement of residual stresses in claddings

    International Nuclear Information System (INIS)

    Hofer, G.; Bender, N.

    1978-01-01

    The ring core method, a variation of the hole drilling method for the measurement of biaxial residual stresses, has been extended to measure stresses from depths of about 5 to 25mm. It is now possible to measure the stress profiles of clad material. Examples of measured stress profiles are shown and compared with those obtained with a sectioning technique. (author)

  15. Convenient measurement of the residual stress using X-ray penetration depth

    International Nuclear Information System (INIS)

    Ukai, Takayoshi; Shibano, Junichi

    1994-01-01

    The residual stress measured with a characteristic X-ray is usually evaluated as a surface stress. However, it is a weighted mean value over all penetration depth of X-ray. Thus, the classical sin 2 Ψ method with the characteristic X-ray is difficult to use for measuring the steep gradient of residual stress that occurs along the depth direction in a subsurface layer of the material after cold rolling and grinding. This paper presents a convenient method of the residual stress measurement along the depth direction in a subsurface layer using the penetration depth depending on a characteristic X-ray. The residual stress distribution of JIS SKS51 steel plate was measured as an example of applying this method. As a result, it could be confirmed that a residual stress distribution along the depth direction in a subsurface layer could be evaluated nondestructively by this convenient method. (author)

  16. Using bomb calorimetry for determination of risk indices of wildfires originating from pine residues

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Regueira, L.; Rodriguez Anon, J.A.; Proupin Castineiras, J.; Vilanova Diz, A.; Romero Garcia, A. [Departamento de Fisica Aplicada, Facultade de Fisica, Universidade de Santiago de Compostela, Campus Sur, 15782 , A Coruna Santiago de Compostela (Spain)

    2002-10-19

    Pine trees, mainly Pinus pinaster Aiton, now cover 640,000ha of the forest occupied surface in Galicia. The possibility of using the residues originating from pine tree exploitation as an alternative energy source could yield to gross benefit around 2.8x10{sup 8} euros per year, together with ecological advantages.The object of the present study is the evaluation of the energy contained in these residues through the measurement of their caloric values using a static bomb calorimeter. At the same time, flammabilities were measured by a standard epiradiator thus allowing the calculation of risk indices. This latter is very important to fight and prevent the start and spreading of forest fires.Elementary chemical composition was also determined using an elementary chemical analyser. Biological and bioclimatic parameters, which are very useful for the evaluation of caloric values and flammabilities over the year, were used for discussion of results.

  17. Residual lifetime and 10 year absolute risks of osteoporotic fractures in Chinese men and women.

    Science.gov (United States)

    Si, Lei; Winzenberg, Tania M; Chen, Mingsheng; Jiang, Qicheng; Palmer, Andrew J

    2015-06-01

    To determine the residual lifetime and 10 year absolute risks of osteoporotic fractures in Chinese men and women. A validated state-transition microsimulation model was used. Microsimulation and probabilistic sensitivity analyses were performed to address the uncertainties in the model. All parameters including fracture incidence rates and mortality rates were retrieved from published literature. Simulated subjects were run through the model until they died to estimate the residual lifetime fracture risks. A 10 year time horizon was used to determine the 10 year fracture risks. We estimated the risk of only the first osteoporotic fracture during the simulation time horizon. The residual lifetime and 10 year risks of having the first osteoporotic (hip, clinical vertebral or wrist) fracture for Chinese women aged 50 years were 40.9% (95% CI: 38.3-44.0%) and 8.2% (95% CI: 6.8-9.3%) respectively. For men, the residual lifetime and 10 year fracture risks were 8.7% (95% CI: 7.5-9.8%) and 1.2% (95% CI: 0.8-1.7%) respectively. The residual lifetime fracture risks declined with age, whilst the 10 year fracture risks increased with age until the short-term mortality risks outstripped the fracture risks. Residual lifetime and 10 year clinical vertebral fracture risks were higher than those of hip and wrist fractures in both sexes. More than one third of the Chinese women and approximately one tenth of the Chinese men aged 50 years are expected to sustain a major osteoporotic fracture in their remaining lifetimes. Due to increased fracture risks and a rapidly ageing population, osteoporosis will present a great challenge to the Chinese healthcare system. While national data was used wherever possible, regional Chinese hip and clinical vertebral fracture incidence rates were used, wrist fracture rates were taken from a Norwegian study and calibrated to the Chinese population. Other fracture sites like tibia, humerus, ribs and pelvis were not included in the analysis, thus these

  18. Health Risk Assessment of Pesticide Residues via Dietary Intake of Market Vegetables from Dhaka, Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Shakhaoat Hossain

    2013-02-01

    Full Text Available The present study was designed to assess the health risk of pesticide residues via dietary intake of vegetables collected from four top agro-based markets of Dhaka, Bangladesh. High performance liquid chromatography with a photo diode array detector (HPLC-PDA was used to determine six organophosphorus (chlorpyrifos, fenitrothion, parathion, ethion, acephate, fenthion, two carbamate (carbaryl and carbofuran and one pyrethroid (cypermethrin pesticide residues in twelve samples of three common vegetables (tomato, lady’s finger and brinjal. Pesticide residues ranged from below detectable limit (<0.01 to 0.36 mg/kg. Acephate, chlorpyrifos, ethion, carbaryl and cypermethrin were detected in only one sample, while co-occurrence occurred twice for fenitrothion and parathion. Apart from chlorpyrifos in tomato and cypermethrin in brinjal, all pesticide residues exceeded the maximum residue limit (MRL. Hazard risk index (HRI for ethion (10.12 and carbaryl (1.09 was found in lady’s finger and tomato, respectively. Rest of the pesticide residues were classified as not a health risk. A continuous monitoring and strict regulation should be enforced regarding control of pesticide residues in vegetables and other food commodities.

  19. The residues and environmental risks of multiple veterinary antibiotics in animal faeces.

    Science.gov (United States)

    Li, Yan-Xia; Zhang, Xue-Lian; Li, Wei; Lu, Xiao-Fei; Liu, Bei; Wang, Jing

    2013-03-01

    To understand the residues and ecological risks of veterinary antibiotics (VAs) in animal faeces from concentrated animal feeding operations in northeastern China, 14 VAs were identified by high performance liquid chromatography, and the preliminary risks of six antibiotics were assessed using the hazard quotient (HQ). The investigated VAs occurred in 7.41 to 57.41 % of the 54 samples, and the levels ranged from 0.08 to 56.81 mg kg(-1). Tetracyclines were predominant with a maximum level of 56.81 mg kg(-1) mostly detected in pig faeces. Sulfonamides were common and detected with the highest concentration of 7.11 mg kg(-1). Fluoroquinolones were more widely detected in chicken faeces rather than in pig or cow faeces, which contained the dominant antibiotic enrofloxacin. In comparison, the residue of tylosin was less frequently found. The risk evaluations of the six antibiotics revealed that tetracyclines, especially oxytetracycline, displayed the greatest ecological risk because of its high HQ value of 15.75. The results of this study imply that multiple kinds of VAs were jointly used in animal feeding processes in the study area. These medicine residues in animal faeces may potentially bring ecological risks if the animal manure is not treated effectively.

  20. Application of x-ray residual stress measurement to products

    International Nuclear Information System (INIS)

    Goto, T.; Iwamura, T.

    1975-01-01

    The X-ray residual stress measuring method is the only nondestructive method for measuring residual stress in polycrystalline materials. It is capable of obtaining information not only on macroscopic stress but also microscopic stress. The authors are employing this method for the development of pre-service and in-service inspection methods and for the improvement of various manufacturing techniques. In this paper, the results of measurement of some products as examples of its application are described. The examples introduced concern the following: (1) Selection of optimum conditions in heat treatment and stress-relief treatment. (2) Residual stress produced by mechanical processes such as autofrettage and flow form. (3) Check of manufacturing processes of rotary shaft and welded parts. (4) Estimation of fatigue strength of shot-peened part. (5) Detection of fatigue damage of shot-peened part. (auth.)

  1. Diffraction measurements of residual stress in titanium matrix composites

    International Nuclear Information System (INIS)

    James, M.R.; Bourke, M.A.; Goldstone, J.A.; Lawson, A.C.

    1993-01-01

    Metal matrix composites develop residual strains after consolidation due to the thermal expansion mismatch between the reinforcement fiber and the matrix. X-ray and neutron diffraction measured values for the longitudinal residual stress in the matrix of four titanium MMCs are reported. For thick composites (> 6 plies) the surface stress measured by x-ray diffraction matches that determined by neutron diffraction and therefore represents the stress in the bulk region consisting of the fibers and matrix. For thin sheet composites, the surface values are lower than in the interior and increase as the outer rows of fibers are approached. While a rationale for the behavior in the thin sheet has yet to be developed, accounting for composite thickness is important when using x-ray measured values to validate analytic and finite element calculations of the residual stress state

  2. Measurements of three dimensional residual stress distribution on laser irradiated spot

    International Nuclear Information System (INIS)

    Tanaka, Hirotomo; Akita, Koichi; Ohya, Shin-ichi; Sano, Yuji; Naito, Hideki

    2004-01-01

    Three dimensional residual stress distributions on laser irradiated spots were measured using synchrotron radiation to study the basic mechanism of laser peening. A water-immersed sample of high tensile strength steel was irradiated with Q-switched and frequency-doubled Nd:YAG laser. The residual stress depth profile of the sample was obtained by alternately repeating the measurement and surface layer removal by electrolytic polishing. Tensile residual stresses were observed on the surface of all irradiated spots, whereas residual stress changed to compressive just beneath the surface. The depth of compressive residual stress imparted by laser irradiation and plastic deformation zone increased with increasing the number of laser pulses irradiated on the same spot. (author)

  3. Distribution of Estimated 10-Year Risk of Recurrent Vascular Events and Residual Risk in a Secondary Prevention Population

    NARCIS (Netherlands)

    Kaasenbrood, Lotte; Boekholdt, S. Matthijs; van der Graaf, Yolanda; Ray, Kausik K.; Peters, Ron J. G.; Kastelein, John J. P.; Amarenco, Pierre; LaRosa, John C.; Cramer, Maarten J. M.; Westerink, Jan; Kappelle, L. Jaap; de Borst, Gert J.; Visseren, Frank L. J.

    2016-01-01

    Among patients with clinically manifest vascular disease, the risk of recurrent vascular events is likely to vary. We assessed the distribution of estimated 10-year risk of recurrent vascular events in a secondary prevention population. We also estimated the potential risk reduction and residual

  4. Measurement of residual stress in quenched 1045 steel by the nanoindentation method

    International Nuclear Information System (INIS)

    Zhu Lina; Xu Binshi; Wang Haidou; Wang Chengbiao

    2010-01-01

    In this paper, the residual stress in quenched AISI 1045 steel was measured by a recently developed nanoindentation technique. Depth control mode was adopted to measure the residual stress. It was found that residual compressive stress was generated in the quenched steel. The material around nanoindents exhibits significant pile-up deformation. A new method was proposed to determine the real contact area for pile-up material on the basis of invariant pile-up morphology of the loaded or unloaded states. The results obtained by the new method were in good agreement with the residual stresses measured by the classical X-ray diffraction (XRD) method. - Research Highlights: → A new method was proposed to measure the real contact area for pile-up materials. → The real contact depth is defined as the sum of h max and the pile-up height h p . → The value of residual stress measured by the nanoindentation method was in good agreement with that by the XRD method.

  5. Measured residual stresses in overlay pipe weldments removed from service

    International Nuclear Information System (INIS)

    Shack, W.J.

    1985-02-01

    Surface and throughwall residual stresses were measured on an elbow-to-pipe weldment that had been removed from the Hatch-2 reactor about a year after the application of a weld overlay. The results were compared with experimental measurements on three mock-up weldments and with finite-element calculations. The comparison shows that there are significant differences in the form and magnitude of the residual stress distributions. However, even after more than a year of service, the residual stresses over most of the inner surface of the actual plant weldment with an overlay were strongly compressive. 3 refs., 7 figs

  6. Assessing food allergy risks from residual peanut protein in highly refined vegetable oil

    NARCIS (Netherlands)

    Blom, W.M.; Kruizinga, A.G.; Rubingh, C.M.; Remington, B.C.; Crevel, R.W.R.; Houben, G.F.

    2017-01-01

    Refined vegetable oils including refined peanut oil are widely used in foods. Due to shared production processes, refined non-peanut vegetable oils can contain residual peanut proteins. We estimated the predicted number of allergic reactions to residual peanut proteins using probabilistic risk

  7. Involved Node, Site, Field and Residual Volume Radiotherapy for Lymphoma: A Comparison of Organ at Risk Dosimetry and Second Malignancy Risks.

    Science.gov (United States)

    Murray, L; Sethugavalar, B; Robertshaw, H; Bayman, E; Thomas, E; Gilson, D; Prestwich, R J D

    2015-07-01

    Recent radiotherapy guidelines for lymphoma have included involved site radiotherapy (ISRT), involved node radiotherapy (INRT) and irradiation of residual volume after full-course chemotherapy. In the absence of late toxicity data, we aim to compare organ at risk (OAR) dose-metrics and calculated second malignancy risks. Fifteen consecutive patients who had received mediastinal radiotherapy were included. Four radiotherapy plans were generated for each patient using a parallel pair photon technique: (i) involved field radiotherapy (IFRT), (ii) ISRT, (iii) INRT, (iv) residual post-chemotherapy volume. The radiotherapy dose was 30 Gy in 15 fractions. The OARs evaluated were: breasts, lungs, thyroid, heart, oesophagus. Relative and absolute second malignancy rates were estimated using the concept of organ equivalent dose. Significance was defined as P risks of second cancers were significantly higher with IFRT compared with ISRT for lung, breast and thyroid; INRT and residual volume resulted in significantly lower relative risks compared with ISRT for lung, breast and thyroid. The median excess absolute risks of second cancers were consistently lowest for the residual technique and highest for IFRT in terms of thyroid, lung and breast cancers. The risk of oesophageal cancer was similar for all four techniques. Overall, the absolute risk of second cancers was very similar for ISRT and INRT. Decreasing treatment volumes from IFRT to ISRT, INRT or residual volume reduces radiation exposure to OARs. Second malignancy modelling suggests that this reduction in treatment volumes will lead to a reduction in absolute excess second malignancy. Little difference was observed in second malignancy risks between ISRT and INRT, supporting the use of ISRT in the absence of a pre-chemotherapy positron emission tomography scan in the radiotherapy treatment position. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Dynamics, Residue and Risk Assessment of Nitenpyram in Rice and Paddy Field

    Directory of Open Access Journals (Sweden)

    YUAN Xue-xia

    2016-09-01

    Full Text Available Residues dynamics, final residual levels and dietary intake risk of nitenpyram in rice and paddy field were investigated in three dif-ferent regions of China(Shandong, Henan and Anhui. A method was illustrated to detect nitenpyram residues in paddy, plant, brown rice, paddy water and soil. The residues in paddy and rice were extracted with methanol+phosphate buffer(0.2 mol·L-1, pH=7.0(60+40, adjust pH to 2.5, then cleaned up with solid phase extraction column and 0.22 μm filter membrane, and then analyzed by HPLC with an ul-traviolet detector at 260 nm. When spiked 0.05, 0.5, 1.0 mg·kg-1, the recoveries of nitenpyram in paddy plant and brown rice were 78.4%~94.7% and 84.0%~94.2%, respectively. The residues in paddy water and soil were extracted with phosphate buffer (0.2 mol·L-1, pH=7.0, when spiked 0.01, 0.5, 1.0 mg·kg-1, the recoveries of nitenpyram in paddy water and soil were 84.6%~98.0% and 93.7%~97.1%, respective-ly, which indicated this method match the requirement of the detection. Two years results showed that nitenpyram belongs to easily degraded pesticides, because all half-lives were below 1.4 d in rice plant, as well as below 4.2 d in paddy water. Final residual levels of nitenpyram in rice were all below 0.05 mg·kg-1,which was far below the Japanese maximum residue limit(0.5 mg·kg-1. The risk quotients (RQs were low for different populations in China, which indicated its low risk in rice. Therefore, the rice with nitenpyram applied, according to the recom-mend method, 45 g·hm-2 application once, with 21 days collection interval, was safe.

  9. A multigene array for measurable residual disease detection in AML patients undergoing SCT

    Science.gov (United States)

    Goswami, M; McGowan, K S; Lu, K; Jain, N; Candia, J; Hensel, N F; Tang, J; Calvo, K R; Battiwalla, M; Barrett, A J; Hourigan, C S

    2015-01-01

    AML is a diagnosis encompassing a diverse group of myeloid malignancies. Heterogeneous genetic etiology, together with the potential for oligoclonality within the individual patient, have made the identification of a single high-sensitivity marker of disease burden challenging. We developed a multiple gene measurable residual disease (MG-MRD) RQ–PCR array for the high-sensitivity detection of AML, retrospectively tested on 74 patients who underwent allo-SCT at the NHLBI in the period 1994–2012. MG-MRD testing on peripheral blood samples prior to transplantation demonstrated excellent concordance with traditional BM-based evaluation and improved risk stratification for post-transplant relapse and OS outcomes. Pre-SCT assessment by MG-MRD predicted all clinical relapses occurring in the first 100 days after allo-SCT compared with 57% sensitivity using WT1 RQ–PCR alone. Nine patients who were negative for WT1 prior to transplantation were correctly reclassified into a high-risk MG-MRD-positive group, associated with 100% post-transplant mortality. This study provides proof of principle that a multiple gene approach may be superior to the use of WT1 expression alone for AML residual disease detection. PMID:25665046

  10. [Joint application of mathematic models in assessing the residual risk of hepatitis C virus transmitted through blood transfusion].

    Science.gov (United States)

    Wang, Xun; Jia, Yao; Xie, Yun-zheng; Li, Xiu-mei; Liu, Xiao-ying; Wu, Xiao-fei

    2011-09-01

    The practicable and effective methods for residual risk assessment on transfusion-transmitted disease was to establish the mathematic models. Based on the characteristics of the repeat donors which donated their blood on a regular base, a model of sero-conversion during the interval of donations was established to assess the incidence of the repeat donors. Based on the characteristics of the prevalence in the population, a model of 'prevalence increased with the age of the donor' was established to assess the incidence of those first-time donors. And based on the impact of the windows period through blood screening program, a model of residual risk associated with the incidence and the length of the windows period was established to assess the residual risk of blood transfusion. In this paper, above said 3 kinds of mathematic models were jointly applied to assess the residual risk of hepatitis C virus (HCV) which was transmitted through blood transfusion in Shanghai, based on data from the routine blood collection and screening program. All the anti-HCV unqualified blood donations were confirmed before assessment. Results showed that the residual risk of HCV transmitted through blood transfusion during Jan. 1(st), 2007 to Dec. 31(st), 2008 in Shanghai was 1:101 000. Data showed that the results of residual risk assessment with mathematic models was valuable. The residual risk of transfusion-transmitted HCV in Shanghai was at a safe level, according to the results in this paper.

  11. [Atherogenic dyslipidemia and residual risk. State of the art in 2014].

    Science.gov (United States)

    Millán Núñez-Cortés, Jesús; Pedro-Botet Montoya, Juan; Pintó Sala, Xavier

    2014-01-01

    Pandemics of metabolic síndrome, obesity, and type 2 diabetes is a major challenge for the next years and supported the grat burden of cardiovascular diseases. The R3i (Residual Risk Reduction initiative) has previously highlighted atherogenic dyslipidaemia as an important and modifiable contributor to the lipid related residual cardiovascular risk. Atherogenic dyslipidaemia is defined as an imbalance between proatherogenic triglycerides-rich apoB-containing lipoproteins and antiatherogenic AI containing lipoproteins. To improve clinical management of atherogenic dyslipidaemia a despite of lifestyle intervention includes pharmacological approach, and fibrates is the main option for combination with a statin to further reduce non-HDL cholesterol. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  12. Functional residual capacity measurement by heptafluoropropane in ventilated newborn lungs

    OpenAIRE

    Kusztrich, Ariane

    2012-01-01

    Objective: Heptafluoropropane is an inert gas commercially used as propellant for inhalers. Since heptafluoropropane can be detected in low concentrations, it could also be used as a tracer gas to measure functional residual capacity. The aim of the present study was to validate functional residual capacity measurements by heptafluoropropane wash-in/wash-out (0.8%) during mechanical ventilation in small, surfactant-depleted lungs using a newborn piglet model. Design: Prospective laborato...

  13. X-ray measurement of residual stress in metals at Chalk River Nuclear Laboratories

    International Nuclear Information System (INIS)

    Winegar, J.E.

    1980-06-01

    X-ray diffraction is used at CRNL to measure residual stress in metals. This report summarizes the basic principles of stress measurement, and reviews factors affecting accuracy of measurement. The technique and equipment described were developed at CRNL to give reliable measurements. Accuracy of measurement is achieved by using fixed-count step-scanning and by computer analysis of intensity data using a cubic spline curve smoothing routine. Specific reference is made to the measurement of residual stress in Inconel-600 and Incoloy-800 boiler tubing. Because it measures stress in thin surface layers, the X-ray method can also be used to measure the depth profile of stresses. As there are no standardized procedures for measuring residual stress, this report will be useful both to those unfamiliar with the measurement of residual stress and to those already making such measurements in other laboratories. (auth)

  14. Neutron diffraction measurements of residual stress in a powder metallurgy component

    International Nuclear Information System (INIS)

    Schneider, L.C.R.; Hainsworth, S.V.; Cocks, A.C.F.; Fitzpatrick, M.E.

    2005-01-01

    Residual stresses in a typical industrial green component were determined using neutron diffraction. The measured residual stresses were found to correlate with cross-sectional variations. Residual stress at the edge of the compact in contact with the die wall during compaction reached up to +80 MPa (tension) and -100 MPa (compression)

  15. Residual Cardiovascular Risk in Diabetic Patients: The Role of Fibrate Statin Combination

    Directory of Open Access Journals (Sweden)

    Angelos Liontos

    2014-10-01

    Full Text Available Patients with Type 2 diabetes mellitus (T2DM have increased cardiovascular disease (CVD risk. The use of statins significantly reduces the rate of CVD events but many T2DM patients, especially those with mixed dyslipidaemia (MD, have residual CVD risk. The use of fibrates, which improve triglyceride and high-density lipoprotein cholesterol levels, is beneficial for the treatment of patients with MD. Evidence from the Action to Control Cardiovascular Risk in Diabetes (ACCORD Lipid study showed a possible beneficial effect on CVD events of the addition of fenofibrate (FF to statin treatment in patients with T2DM and atherogenic MD. Furthermore, FF has been associated with slowing of the progression of early diabetic retinopathy. The combination of statin with a fibrate may improve the residual CVD risk and microvascular complications of patients with T2DM. However, trials specifically designed to assess the effects of fibrate-statin combination on cardiovascular outcomes in patients with T2DM are missing.

  16. Organic amendments for risk mitigation of organochlorine pesticide residues in old orchard soils

    Science.gov (United States)

    Centofantia, Tiziana; McConnell, Laura L.; Chaney, Rufus L.; Beyer, W. Nelson; Andradea, Natasha A.; Hapeman, Cathleen J.; Torrents, Alba; Nguyen, Anh; Anderson, Marya O.; Novak, J. M.; Jackson, Dana

    2015-01-01

    Performance of compost and biochar amendments for in situ risk mitigation of aged DDT, DDE and dieldrin residues in an old orchard soil was examined. The change in bioavailability of pesticide residues to Lumbricus terrestris L. relative to the unamended control soil was assessed using 4-L soil microcosms with and without plant cover in a 48-day experiment. The use of aged dairy manure compost and biosolids compost was found to be effective, especially in the planted treatments, at lowering the bioavailability factor (BAF) by 18–39%; however, BAF results for DDT in the unplanted soil treatments were unaffected or increased. The pine chip biochar utilized in this experiment was ineffective at lower the BAF of pesticides in the soil. The US EPA Soil Screening Level approach was used with our measured values. Addition of 10% of the aged dairy manure compost reduced the average hazard quotient values to below 1.0 for DDT + DDE and dieldrin. Results indicate this sustainable approach is appropriate to minimize risks to wildlife in areas of marginal organochlorine pesticide contamination. Application of this remediation approach has potential for use internationally in areas where historical pesticide contamination of soils remains a threat to wildlife populations.

  17. Non-Destructive Measurement of Residual Strain in Connecting Rods Using Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Tomohiro [Honda R& D; Bunn, Jeffrey R. [ORNL; Fancher, Christopher M. [ORNL; Seid, Alan [Honda R& D; Motani, Ryuta [Honda R& D; Matsuda, Hideki [Honda R& D; Okayama, Tatsuya [Honda R& D

    2018-04-01

    Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases in where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this paper consists of non-destructive residual strain measurements in the interior of connecting rods using the 2nd Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory, measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of connecting rod, which prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however the peak width can additionally be caused by microstresses and material dislocations.

  18. Residual stress distribution in carbon steel pipe welded joint measured by neutron diffraction

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Ishiwata, Masayuki; Morii, Yukio; Minakawa, Nobuaki

    2000-01-01

    In order to estimate crack growth behavior of fatigue and stress corrosion cracking in pipes, the residual stress distribution near the pipe weld region has to be measured through the wall thickness. Since the penetration depth of neutron is deep enough to pass through the thick pipe wall, the neutron diffraction technique for the residual stress measurement is effective for this purpose. At the first step the residual stress distribution near the weld region in a butt-welded carbon steel pipe was measured by the neutron diffraction. Significant stresses extended only to a distance of 30 mm from the center of the weld. The major tensile stresses occurred in the hoop direction in the fusion and heat affected zones of the weldment, and they attained a level greater than 200 MPa through the thickness. While the axial residual stress at the inside surface was 50 MPa, the stress at the outside surface was -100 MPa. The comparison of residual stress distributions measured by the neutron diffraction, the X-ray diffraction and the strain gauge method reveals that the neutron diffraction is the most effective for measuring the residual stress inside the structural components. (author)

  19. Uncertainty Quantification and Comparison of Weld Residual Stress Measurements and Predictions.

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, John R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    In pressurized water reactors, the prevention, detection, and repair of cracks within dissimilar metal welds is essential to ensure proper plant functionality and safety. Weld residual stresses, which are difficult to model and cannot be directly measured, contribute to the formation and growth of cracks due to primary water stress corrosion cracking. Additionally, the uncertainty in weld residual stress measurements and modeling predictions is not well understood, further complicating the prediction of crack evolution. The purpose of this document is to develop methodology to quantify the uncertainty associated with weld residual stress that can be applied to modeling predictions and experimental measurements. Ultimately, the results can be used to assess the current state of uncertainty and to build confidence in both modeling and experimental procedures. The methodology consists of statistically modeling the variation in the weld residual stress profiles using functional data analysis techniques. Uncertainty is quantified using statistical bounds (e.g. confidence and tolerance bounds) constructed with a semi-parametric bootstrap procedure. Such bounds describe the range in which quantities of interest, such as means, are expected to lie as evidenced by the data. The methodology is extended to provide direct comparisons between experimental measurements and modeling predictions by constructing statistical confidence bounds for the average difference between the two quantities. The statistical bounds on the average difference can be used to assess the level of agreement between measurements and predictions. The methodology is applied to experimental measurements of residual stress obtained using two strain relief measurement methods and predictions from seven finite element models developed by different organizations during a round robin study.

  20. Residual stress measurement of large scaled welded pipe using neutron diffraction method. Effect of SCC crack propagation and repair weld on residual stress distribution

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Katsuyama, Jinya; Tobita, Tohru; Morii, Yukio

    2011-01-01

    The RESA-1 neutron engineering diffractometer in the JRR-3 (Japan Research Reactor No.3) at the Japan Atomic Energy Agency, which is used for stress measurements, was upgraded to realize residual stress measurements of large scaled mechanical components. A series of residual stress measurements was made to obtain through-thickness residual stress distributions in a Type 304 stainless steel butt-welded pipe of 500A-sch.80 using the upgraded RESA-1 diffractometer. We evaluated effects of crack propagation such as stress corrosion cracking (SCC) and a part-circumference repair weld on the residual stress distributions induced by girth welding. Measured residual stress distributions near original girth weld revealed good agreement with typical results shown in some previous works using finite element method, deep hole drilling as well as neutron diffraction. After introducing a mock crack with 10 mm depth in the heat affected zone on the inside wall of the pipe by electro discharge machining, the axial residual stresses were found to be released in the part of the mock crack. However, changes in the through-wall bending stress component and the self-equilibrated stress component were negligible and hence the axial residual stress distribution in the ligament was remained in the original residual stresses near girth weld without the mock crack. Furthermore, changes in hoop and radial residual stress were also small. The residual stress distributions after a part repair welding on the outer circumference of the girth weld were significantly different from residual stress distributions near the original girth weld. The through-thickness average axial residual stress was increased due to increase of the tensile membrane stress and mitigation of the bending stress after repair welding. Throughout above studies, we evidenced that the neutron diffraction technique is useful and powerful tool for measuring residual stress distributions in large as well as thick mechanical

  1. Fact Sheet for Friction Materials Manufacturing Facilities Residual Risk and Technology Review

    Science.gov (United States)

    proposed amendments to the National Emission Standards for Hazardous Air Pollutants (NESHAP) for Friction Materials Manufacturing Facilities to address the results of the residual risk and technology review

  2. Neutron diffraction measurement of residual stress in NPP construction materials

    International Nuclear Information System (INIS)

    Hinca, R.; Bokuchava, G.

    2000-01-01

    The aim of the investigation is to study the level of residual stresses induced by the surfacing in the weld deposit zone and in the base metal, where considerable thermal gradients are present. Surfacing high-nickel filler on an austenitic base metal is one of techniques in repair of primary collector the primary circuit of nuclear power plant type VVER. The repair technology was developed at Welding Research Institute Bratislava. Measurements of residual stresses in the weld overlay and the base metal are necessary for approving the mechanical analysis and verifying of residual stresses determination on welded material by numerical weld g computer simulation. Investigations of residual stresses are important for developing optimal welding techniques. (authors)

  3. Donor testing and risk: current prevalence, incidence, and residual risk of transfusion-transmissible agents in US allogeneic donations.

    Science.gov (United States)

    Zou, Shimian; Stramer, Susan L; Dodd, Roger Y

    2012-04-01

    Over the past 20 years, there has been a major increase in the safety of the blood supply, as demonstrated by declining rates of posttransfusion infection and reductions in estimated residual risk for such infections. Reliable estimates of residual risk have been possible within the American Red Cross system because of the availability of a large amount of reliable and consistent data on donations and infectious disease testing results. Among allogeneic blood donations, the prevalence rates of infection markers for hepatitis C virus (HCV) and hepatitis B virus have decreased over time, although rates for markers of human immunodeficiency virus (HIV) and human T-cell lymphotropic virus did not. The incidence (/100 000 person-years) of HIV and HCV among repeat donors showed apparent increases from 1.55 and 1.89 in 2000 through 2001 to 2.16 and 2.98 in 2007 through 2008. These observed fluctuations confirm the need for continuous monitoring and evaluation. The residual risk of HIV, HCV, and human T-cell lymphotropic virus among all allogeneic donations is currently below 1 per 1 million donations, and that of hepatitis B surface antigen is close to 1 per 300 000 donations. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Atherogenic Dyslipidemia and Residual Vascular Risk in Practice of Family Doctor

    OpenAIRE

    Alibasic, Esad; Ramic, Enisa; Bajraktarevic, Amila; Ljuca, Farid; Batic-Mujanovic, Olivera; Zildzic, Muharem

    2015-01-01

    Objective: Timely recognition and optimal management of atherogenic dyslipidemia (AD) and residual vascular risk (RVR) in family medicine. Background: The global increase of the incidence of obesity is accompanied by an increase in the incidence of many metabolic and lipoprotein disorders, in particular AD, as an typical feature of obesity, metabolic syndrome, insulin resistance and diabetes type 2. AD is an important factor in cardio metabolic risk, and is characterized by a lipoprotein prof...

  5. Comparison of residual stress measurement in thin films using surface micromachining method

    International Nuclear Information System (INIS)

    He, Q.; Luo, Z.X.; Chen, X.Y.

    2008-01-01

    Conductive, dielectric, semiconducting, piezoelectric and ferroelectric thin films are extensively used for MEMS/NEMS applications. One of the important parameters of thin films is residual stress. The residual stress can seriously affect the properties, performance and long-term stability of the films. Excessive compressive or tensile stress results in buckling, cracking, splintering and sticking problems. Stress measurement techniques are therefore essential for both process development and process monitoring. Many suggestions for stress measurement in thin films have been made over the past several decades. This paper is concentrated on the in situ stress measurement using surface micromachining techniques to determine the residual stress. The authors review and compare several types of stress measurement methods including buckling technique, rotating technique, micro strain gauge and long-short beam strain sensor

  6. Risk-based approach to developing a national residue sampling plan for testing under European Union regulation for veterinary medicinal products and coccidiostat feed additives in domestic animal production.

    Science.gov (United States)

    Danaher, Martin; Shanahan, Conor; Butler, Francis; Evans, Rhodri; O'Sullivan, Dan; Glynn, Denise; Camon, Tim; Lawlor, Peadar; O'Keeffe, Michael

    2016-07-01

    A ranking system for veterinary medicinal products and coccidiostat feed additives has been developed as a tool to be applied in a risk-based approach to the residue testing programme for foods of animal origin in the Irish National Residue Control Plan (NRCP). Three characteristics of substances that may occur as residues in food are included in the developed risk ranking system: Potency, as measured by the acceptable daily intake assigned by the European Medicines Agency Committee for Medicinal Products for Veterinary Use, to each substance; Usage, as measured by the three factors of Number of Doses, use on Individual animals or for Group treatment, and Withdrawal Period; and Residue Occurrence, as measured by the number of Non-Compliant Samples in the NRCP. For both Number of Doses and Non-Compliant Samples, data for the 5-year period 2008-12 have been used. The risk ranking system for substances was developed for beef cattle, sheep and goats, pigs, chickens and dairy cattle using a scoring system applied to the various parameters described above to give an overall score based on the following equation: Potency × Usage (Number of Doses + Individual/Group Use + Withdrawal Period) × Residue Occurrence. Applying this risk ranking system, the following substances are ranked very highly: antimicrobials such as amoxicillin (for all species except pigs), marbofloxacillin (for beef cattle), oxytetracycline (for all species except chickens), sulfadiazine with trimethoprim (for pigs and chickens) and tilmicosin (for chickens); antiparasitic drugs, such as the benzimidazoles triclabendazole (for beef and dairy cattle), fenbendazole/oxfendazole (for sheep/goats and dairy cattle) and albendazole (for dairy cattle), the avermectin ivermectin (for beef cattle), and anti-fluke drugs closantel and rafoxanide (for sheep/goats); the anticoccidials monensin, narasin, nicarbazin and toltrazuril (for chickens). The risk ranking system described is a relatively simple system

  7. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation.

    Science.gov (United States)

    Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K

    2017-07-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n  = 5) and transfemoral ( n  = 5) amputation were compared to able-limb controls ( n  = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.

  8. Residual stress measurement in 304 stainless steel weld overlay pipes

    International Nuclear Information System (INIS)

    Yen, H.J.; Lin, M.C.C.; Chen, L.J.

    1996-01-01

    Welding overlay repair (WOR) is commonly employed to rebuild piping systems suffering from intergranular stress corrosion cracking (IGSCC). To understand the effects of this repair, it is necessary to investigate the distribution of residual stresses in the welding pipe. The overlay welding technique must induce compressive residual stress at the inner surface of the welded pipe to prevent IGSCC. To understand the bulk residual stress distribution, the stress profile as a function of location within wall is examined. In this study the full destructive residual stress measurement technique -- a cutting and sectioning method -- is used to determine the residual stress distribution. The sample is type 304 stainless steel weld overlay pipe with an outside diameter of 267 mm. A pipe segment is cut from the circular pipe; then a thin layer is removed axially from the inner to the outer surfaces until further sectioning is impractical. The total residual stress is calculated by adding the stress relieved by cutting the section away to the stress relieved by axially sectioning. The axial and hoop residual stresses are compressive at the inner surface of the weld overlay pipe. Compressive stress exists not only at the surface but is also distributed over most of the pipe's cross section. On the one hand, the maximum compressive hoop residual stress appears at the pipe's inner surface. The thermal-mechanical induced crack closure from significant compressive residual stress is discussed. This crack closure can thus prevent IGSCC very effectively

  9. X-ray diffraction and measurement of residual stresses

    International Nuclear Information System (INIS)

    Maeder, G.; Lebrun, J.L.; Corcaud, L.

    1977-01-01

    X-ray diffraction technique is a non destructive method for measuring the residual stresses in mechanical parts. This method, called sin 2 PSI method is investigated. It is applied to the measurement of elastic constants in different directions of crystals of Zr alloy (Zircaloy 4) and Ti alloy (TA6V). Stresses in TA6V sheets welded by TIG and electron beam processes are also studied [fr

  10. Pesticide residues in leafy vegetables and human health risk assessment in North Central agricultural areas of Chile.

    Science.gov (United States)

    Elgueta, Sebastian; Moyano, Stella; Sepúlveda, Paulina; Quiroz, Carlos; Correa, Arturo

    2017-06-01

    To investigate pesticide residue concentrations and potential human health risk, a study was conducted in 118 leafy vegetable samples collected in 2014-2015 from the North Central agricultural areas of Chile. The pesticide residues were determined using the multiresidue QuEChERS method by gas chromatography as well as high-performance liquid chromatography. The results indicated that 27% of the total samples contained pesticide residues above the maximum residue limits of each active ingredient. The maximum estimated daily intake obtained for carbon disulphide (CS 2 ), methamidophos, azoxystrobin and cypermethrin were 0.57, 0.07, 0.06 and 0.05 mg kg -1 , respectively, which was higher than their acceptable daily intake. It is concluded that inhabitants of the North Central agricultural area of Chile are not exposed to health risks through the consumption of leafy vegetables with the exception of methamidophos. Nevertheless, the high levels of methamidophos detected in leafy vegetables could be considered a potential chronic health risk.

  11. Pesticide residues in grain from Kazakhstan and potential health risks associated with exposure to detected pesticides.

    Science.gov (United States)

    Lozowicka, B; Kaczynski, P; Paritova, Capital A Cyrillic Е; Kuzembekova, G B; Abzhalieva, A B; Sarsembayeva, N B; Alihan, K

    2014-02-01

    This paper presents the first study of pesticide residue results in grain from Kazakhstan. A total of 80 samples: barley, oat, rye, and wheat were collected and tested in the accredited laboratory. Among 180 pesticides, 10 active substances were detected. Banned pesticides, such as DDTs, γ-HCH, aldrin and diazinon were found in cereal grain. Chlorpyrifos methyl and pirimiphos methyl were the most frequently detected residues. No residues were found in 77.5% of the samples, 13.75% contained pesticide residues at or below MRLs, and 8.75% above MRLs. The greatest percentage of samples with residues (29%) was noted for wheat, and the lowest for rye (20%). Obtained data were used to estimate potential health risks associated with exposure to these pesticides. The highest estimated daily intakes (EDIs) were as follows: 789% of the ADI for aldrin (wheat) and 49.8% of the ADI for pirimiphos methyl (wheat and rye). The acute risk from aldrin and tebuconazole in wheat was 315.9% and 98.7% ARfD, respectively. The results show that despite the highest EDIs of pesticide residues in cereals, the current situation could not be considered a serious public health problem. Nevertheless, an investigation into continuous monitoring of pesticide residues in grain is recommended. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Predictions and measurements of residual stress in repair welds in plates

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.B. [Mitsui Babcock Energy Limited, Technology and Engineering, Porterfield Road, Renfrew, PA4 8DJ, Scotland (United Kingdom)]. E-mail: bbrown@mitsuibabcock.com; Dauda, T.A. [Mitsui Babcock Energy Limited, Technology and Engineering, Porterfield Road, Renfrew, PA4 8DJ, Scotland (United Kingdom); Truman, C.E. [Department of Mechanical Engineering, University of Bristol, Bristol BS8 1TR, England (United Kingdom); Smith, D.J. [Department of Mechanical Engineering, University of Bristol, Bristol BS8 1TR (United Kingdom); Memhard, D. [Fraunhofer-Institut fuer Werkstoffmechanik, Freiburg (Germany); Pfeiffer, W. [Fraunhofer-Institut fuer Werkstoffmechanik, Freiburg (Germany)

    2006-11-15

    This paper presents the work, from the European Union FP-5 project ELIXIR, on a series of rectangular repair welds in P275 and S690 steels to validate the numerical modelling techniques used in the determination of the residual stresses generated during the repair process. The plates were 1,000 mm by 800 mm with thicknesses of 50 and 100 mm. The repair welds were 50%, 75% and 100% through the plate thickness. The repair welds were modelled using the finite element method to make predictions of the as-welded residual stress distributions. These predictions were compared with surface-strain measurements made on the parent plates during welding and found to be in good agreement. Through-thickness residual stress measurements were obtained from the test plates through, and local to, the weld repairs using the deep hole drilling technique. Comparisons between the measurements and the finite element predictions generally showed good agreement, thus providing confidence in the method.

  13. Predictions and measurements of residual stress in repair welds in plates

    International Nuclear Information System (INIS)

    Brown, T.B.; Dauda, T.A.; Truman, C.E.; Smith, D.J.; Memhard, D.; Pfeiffer, W.

    2006-01-01

    This paper presents the work, from the European Union FP-5 project ELIXIR, on a series of rectangular repair welds in P275 and S690 steels to validate the numerical modelling techniques used in the determination of the residual stresses generated during the repair process. The plates were 1,000 mm by 800 mm with thicknesses of 50 and 100 mm. The repair welds were 50%, 75% and 100% through the plate thickness. The repair welds were modelled using the finite element method to make predictions of the as-welded residual stress distributions. These predictions were compared with surface-strain measurements made on the parent plates during welding and found to be in good agreement. Through-thickness residual stress measurements were obtained from the test plates through, and local to, the weld repairs using the deep hole drilling technique. Comparisons between the measurements and the finite element predictions generally showed good agreement, thus providing confidence in the method

  14. Residual stress measurement of the jacket material for ITER coil by neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Nickel-Iron based super alloy INCOLOY 908 is used for the jacket of a central solenoid coil (CS coil) of the International Thermonuclear Experimental Reactor (ITER). INCOLOY 908, however, has a possibility of fracture due to Stress Accelerated Grain Boundary Oxidation (SAGBO) under a tensile residual stress beyond 200MPa. Therefore it is necessary to measure the residual stress of the jacket to avoid SAGBO. We performed residual stress measurement of the jacket by neutron diffraction using the neutron diffractometer for residual stress analysis (RESA) installed at JRR-3M in JAERI. A sample depth dependence of internal strain was obtained from the (111) plane spacing. A residual stress distribution was calculated from the strain using Young`s modulus and Poisson`s ratio that were evaluated by a tensile test with neutron diffraction. The result shows that the tensile residual stress exceeds 200MPa of the SAGBO condition in some regions inside the jacket. (author)

  15. Prevention of damage and 'residual risk' in nuclear power laws

    International Nuclear Information System (INIS)

    Greipl, C.

    1992-01-01

    The concept of prevention of damage within the framework of nuclear power laws includes averting danger for the protection of third parties and preventing risks for the partial protection of third parties with the proviso that still a desire to use the concept 'residual risk' in addition, it should be limited, on the grounds of what can be reasonably expected, to those risks which cannot be reduced any further by the government, i.e. to risks which the public in general and third parties ('actually') must accept. In the future, questions regarding safety systems should be taken into account exclusively withing the context of 'what is necessary for protection against damage in keeping with the latest developments in science and technology' and not at the discretion of the law in denying permission according to Article 7 Paragraph 2 Atomic Energy Law. (orig.) [de

  16. Risk assessment and risk management at the Canadian Food Inspection Agency (CFIA): a perspective on the monitoring of foods for chemical residues.

    Science.gov (United States)

    Bietlot, Henri P; Kolakowski, Beata

    2012-08-01

    The Canadian Food Inspection Agency (CFIA) uses 'Ranked Risk Assessment' (RRA) to prioritize chemical hazards for inclusion in monitoring programmes or method development projects based on their relative risk. The relative risk is calculated for a chemical by scoring toxicity and exposure in the 'risk model scoring system' of the Risk Priority Compound List (RPCL). The relative ranking and the risk management options are maintained and updated in the RPCL. The ranking may be refined by the data generated by the sampling and testing programs. The two principal sampling and testing programmes are the National Chemical Residue Monitoring Program (NCRMP) and the Food Safety Action Plan (FSAP). The NCRMP sampling plans focus on the analysis of federally registered products (dairy, eggs, honey, meat and poultry, fresh and processed fruit and vegetable commodities, and maple syrup) for residues of veterinary drugs, pesticides, environmental contaminants, mycotoxins, and metals. The NCRMP is complemented by the Food Safety Action Plan (FSAP) targeted surveys. These surveys focus on emerging chemical hazards associated with specific foods or geographical regions for which applicable maximum residue limits (MRLs) are not set. The data from the NCRMP and FSAP also influence the risk management (follow-up) options. Follow-up actions vary according to the magnitude of the health risk, all with the objective of preventing any repeat occurrence to minimize consumer exposure to a product representing a potential risk to human health. © Her Majesty the Queen in Right of Canada 2012. Drug Testing and Analysis © 2012 John Wiley & Sons, Ltd.

  17. Reduction of negative environmental impact generated by residues of plant tissue culture laboratory

    Directory of Open Access Journals (Sweden)

    Yusleidys Cortés Martínez

    2016-01-01

    Full Text Available The research is based on the activity developed by teaching and research laboratories for biotechnology purposes with an environmental approach to determine potential contamination risk and analyze the residuals generated. The physical - chemical characterization of the residuals was carried out from contamination indicators that can affect the dumping of residual water. In order to identify the environmental risks and sources of microbial contamination of plant material propagated by in vitro culture that generate residuals, all the risk activities were identified, the type of risk involved in each activity was analyzed, as well as whether or not the standards were met of aseptic normative. The dilution and neutralization was proposed for residuals with extreme values of pH. Since the results of the work a set of measures was proposed to reduce the negative environmental impact of the laboratory residuals. Key words: biosafety, environmental management, microbial contamination

  18. Atherogenic Dyslipidemia and Residual Cardiovascular Risk in Statin-Treated Patients

    DEFF Research Database (Denmark)

    Sirimarco, Gaia; Labreuche, Julien; Bruckert, Eric

    2014-01-01

    BACKGROUND AND PURPOSE: Treatment with statins reduces the rate of cardiovascular events in high-risk patients, but residual risk persists. At least part of that risk may be attributable to atherogenic dyslipidemia characterized by low high-density lipoprotein cholesterol (≤40 mg/dL) and high......% of subjects in PERFORM and 9% in SPARCL had atherogenic dyslipidemia after ≥3 months on start statin therapy. After a follow-up of 2.3 years (PERFORM) and 4.9 years (SPARCL), a major cardiovascular event occurred in 1123 and 485 patients in the 2 trials, respectively. The risk of major cardiovascular events...... was higher in subjects with versus those without atherogenic dyslipidemia in both PERFORM (hazard ratio, 1.36; 95% confidence interval, 1.14-1.63) and SPARCL (hazard ratio, 1.40; 95% confidence interval, 1.06-1.85). The association was attenuated after multivariable adjustment (hazard ratio, 1.23; 95...

  19. Measurements of residual deformations of steel-aluminum conductors in operating overhead lines

    Energy Technology Data Exchange (ETDEWEB)

    Durov, E.V.; Kesel' man, L.M.; Treiger, A.S.

    1982-12-01

    Experience in the operation of overhead power lines using steel-aluminum conductors is presented. Measurements were taken on the residual deformation of the steel-aluminum lines to determine the amount of sag increase and to forecast this increase for the entire period of operation. It is recommended that the work on measuring the residual deformation in the power lines be extended to a broader range of operating conditions such as conductors, spans, and climate conditions.

  20. Identifying measures to balance the risk profile of the Tihange 2 NPP

    International Nuclear Information System (INIS)

    D'Eer, A.M.; Monniez, J.J.

    2001-01-01

    In Belgium, each Nuclear Power Plant is subject to a periodic safety reassessment. In this context, it was found to be desirable to perform a Probabilistic Safety Assessment (PSA) in support of the ten yearly back-fitting process. The Tihange 2 NPP is a 3-loop PWR having a thermal capacity of 2905 MW. Analysis of the plant's risk profile shows that implementing feasible measures for improvement of the shutdown risk, would be beneficial. This is because a configuration leading to significant risk, namely cold pressurization when the residual heat removal system is lost during reduced primary inventory, thus can be avoided. As a result the risk between reactor shutdown and power operation will be balanced. The presentation describes the lessons learnt regarding the Tihange 2 shutdown PSA model and the expected benefits following implementation of one of the proposed measures. (author)

  1. Comparison of neutron and synchrotron diffraction measurements of residual stress in bead-on-plate weldments

    International Nuclear Information System (INIS)

    Paradowska, A.M.; Price, J.W.; Finlayson, T.R.; Lienert, U.; Ibrahim, R.

    2010-01-01

    This paper explores the use of neutron and synchrotron diffractions for the evaluation of residual stresses in welded components. It has been shown that it is possible to achieve very good agreement between the two independent diffraction techniques. This study shows the significance of the weld start and end sites on the residual strain/stress distribution. Quantitative evaluation of the residual stress development process for multibead weldments has been presented. Some measurements were also taken before and after postweld stress relieving to establish the reduction and redistribution of the residual stress. The detailed measurements of residual stress around the weld achieved in this work significantly improve the knowledge and understanding of residual stress in welded components.

  2. Solid residues

    International Nuclear Information System (INIS)

    Mulder, E.; Duin, P.J. van; Grootenboer, G.J.

    1995-01-01

    A summary is presented of the many investigations that have been done on solid residues of atmospheric fluid bed combustion (AFBC). These residues are bed ash, cyclone ash and bag filter ash. Physical and chemical properties are discussed and then the various uses of residues (in fillers, bricks, gravel, and for recovery of aluminium) are summarised. Toxicological properties of fly ash and stack ash are discussed as are risks of pneumoconiosis for workers handling fly ash, and contamination of water by ashes. On the basis of present information it is concluded that risks to public health from exposure to emissions of coal fly ash from AFBC appear small or negligible as are health risk to workers in the coal fly ash processing industry. 35 refs., 5 figs., 12 tabs

  3. Impacts of channel morphology on residues and ecological risks of polychlorinated biphenyls in water and sediment in Chahe River

    Directory of Open Access Journals (Sweden)

    Zhen-hua Zhao

    2016-10-01

    Full Text Available The impacts of channel morphology on the residues and ecological risks of 14 polychlorinated biphenyl (PCB congeners in water and sediment were investigated in summer (July and autumn (September in the Chahe River, in Nanjing, China. The residual concentrations of tri-chlorobiphenyls (tri-CBs, PCB 18 and tetra-CBs (PCB 52 in water were significantly higher than those of penta-CBs to deca-CBs, and the average residual concentration of ∑PCBs (sum of 14 PCB congeners in summer was about six times higher than in autumn. However, the residues in sediment did not change significantly. Redundancy analysis (RDA indicated that channel morphology and the corresponding environmental indices had significant impacts on PCB residues and their composition profiles in water and sediment. The overflow weir and lake-type watercourse may remarkably reduce the residual concentration and ecological risks of PCBs in water. The highest reduction percentages of the residual concentration and ecological risks of ∑PCBs induced by an overflow weir were 78% and 67%, respectively, and those induced by a lake-type watercourse were 36% and 70%, respectively. The watercourses with different channel morphologies were ranked by residual ∑PCBs concentrations in the following descending order: the natural ecological watercourse, vertical concrete watercourse, and vegetation-type riprap watercourse. However, they were ranked by residual ∑PCBs concentrations in sediment in the following descending order: the vertical concrete watercourse, vegetation-type riprap watercourse, and natural ecological watercourse.

  4. Dermal insecticide residues from birds inhabiting an orchard

    Science.gov (United States)

    Vyas, N.B.; Spann, J.W.; Hulse, C.S.; Gentry, S.; Borges, S.L.

    2007-01-01

    The US Environmental Protection Agency conducts risk assessments of insecticide applications to wild birds using a model that is limited to the dietary route of exposure. However, free-flying birds are also exposed to insecticides via the inhalation and dermal routes. We measured azinphos-methyl residues on the skin plus feathers and the feet of brown-headed cowbirds (Molothrus ater) in order to quantify dermal exposure to songbirds that entered and inhabited an apple (Malus x domestica) orchard following an insecticide application. Exposure to azinphos-methyl was measured by sampling birds from an aviary that was built around an apple tree. Birds sampled at 36 h and 7-day post-application were placed in the aviary within 1 h after the application whereas birds exposed for 3 days were released into the aviary 4-day post-application. Residues on vegetation and soil were also measured. Azinphos-methyl residues were detected from the skin plus feathers and the feet from all exposure periods. Our results underscore the importance of incorporating dermal exposure into avian pesticide risk assessments.

  5. Residual stress measurement by X-ray diffraction with the Gaussian curve method and its automation

    International Nuclear Information System (INIS)

    Kurita, M.

    1987-01-01

    X-ray technique with the Gaussian curve method and its automation are described for rapid and nondestructive measurement of residual stress. A simplified equation for measuring the stress by the Gaussian curve method is derived because in its previous form this method required laborious calculation. The residual stress can be measured in a few minutes, depending on materials, using an automated X-ray stress analyzer with a microcomputer which was developed in the laboratory. The residual stress distribution of a partially induction hardened and tempered (at 280 0 C) steel bar was measured with the Gaussian curve method. A sharp residual tensile stress peak of 182 MPa appeared right outside the hardened region at which fatigue failure is liable to occur

  6. Neutron measurement of residual stresses in a used railway rail

    International Nuclear Information System (INIS)

    Webster, P.J.; Low, K.S.; Mills, G.; Webster, G.A.

    1990-01-01

    The high resolution neutron diffraction technique has been applied to determine, non-destructively, the residual stress distribution developed in the head of a railway rail after normal service. Measurements were made, using the neutron strain scanner at the Institute Laue Langevin, Grenoble, on a transverse slice of rail 12mm thick taken from a section of straight track. The rail head was scanned in the three principal orientations in a series of parallel traverses sufficiently close to enable a two-dimensional matrix of data to be accumulated and vertical, transverse and longitudinal residual stress contours to be drawn. The results demonstrate the effectiveness and unique characteristics of the neutron technique to determine nondestructively and continuously the residual stresses inside engineering components

  7. [Residual risk: The roles of triglycerides and high density lipoproteins].

    Science.gov (United States)

    Grammer, Tanja; Kleber, Marcus; Silbernagel, Günther; Scharnagl, Hubert; März, Winfried

    2016-06-01

    In clinical trials, the reduction of LDL-cholesterol (LDL-C) with statins reduces the incidence rate of cardiovascular events by approximately one third. This means, that a sizeable "residual risk" remains. Besides high lipoprotein (a), disorders in the metabolism of triglyceride-rich lipoproteins and high density liproteins have been implicated as effectors of the residual risk. Both lipoprotein parameters correlate inversely with each other. Therefore, the etiological contributions of triglycerides and / or of HDL for developing cardiovascular disease can hardly be estimated from either observational studies or from intervention studies. The largely disappointing results of intervention studies with inhibitors of the cholesteryl ester transfer protein and in particular the available set of genetically-epidemiological studies suggest that in the last decade, the importance of HDL cholesterol has been overvalued, while the importance of triglycerides has been underestimated. High triglycerides not always atherogenic, but only if they are associated with the accumulation relatively cholesterol-enriched, incompletely catabolized remnants of chylomicrons and very low density lipoproteins (familial type III hyperlipidemia, metabolic syndrome, diabetes mellitus). The normalization of the concentration of triglycerides and remnants by inhibiting the expression of apolipoprotein C3 is hence a new, promising therapeutic target. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Measurement of residual stress fields in FHPP welding: a comparison between DSPI combined with hole-drilling and neutron diffraction

    Science.gov (United States)

    Viotti, Matias R.; Albertazzi, Armando; Staron, Peter; Pisa, Marcelo

    2013-04-01

    This paper shows a portable device to measure mainly residual stress fields outside the optical bench. This system combines the traditional hole drilling technique with Digital Speckle Pattern Interferometry. The novel feature of this device is the high degree of compaction since only one base supports simultaneously the measurement module and the hole-drilling device. The portable device allows the measurement of non-uniform residual stresses in accordance with the ASTM standard. In oil and gas offshore industries, alternative welding procedures among them, the friction hydro pillar processing (FHPP) is highlighted and nowadays is an important maintenance tool since it has the capability to produce structure repairs without risk of explosions. In this process a hole is drilled and filled with a consumable rod of the same material. The rod, which could be cylindrical or conical, is rotated and pressed against the hole, leading to frictional heating. In order to assess features about the residual stress distribution generated by the weld into the rod as well as into the base material around the rod, welded samples were evaluated by neutron diffraction and by the hole drilling technique having a comparison between them. For the hole drilling technique some layers were removed by using electrical discharge machining (EDM) after diffraction measurements in order to assess the bulk stress distribution. Results have shown a good agreement between techniques.

  9. Statistical inference on residual life

    CERN Document Server

    Jeong, Jong-Hyeon

    2014-01-01

    This is a monograph on the concept of residual life, which is an alternative summary measure of time-to-event data, or survival data. The mean residual life has been used for many years under the name of life expectancy, so it is a natural concept for summarizing survival or reliability data. It is also more interpretable than the popular hazard function, especially for communications between patients and physicians regarding the efficacy of a new drug in the medical field. This book reviews existing statistical methods to infer the residual life distribution. The review and comparison includes existing inference methods for mean and median, or quantile, residual life analysis through medical data examples. The concept of the residual life is also extended to competing risks analysis. The targeted audience includes biostatisticians, graduate students, and PhD (bio)statisticians. Knowledge in survival analysis at an introductory graduate level is advisable prior to reading this book.

  10. Measurement of edge residual stresses in glass by the phase-shifting method

    Science.gov (United States)

    Ajovalasit, A.; Petrucci, G.; Scafidi, M.

    2011-05-01

    Control and measurement of residual stress in glass is of great importance in the industrial field. Since glass is a birefringent material, the residual stress analysis is based mainly on the photoelastic method. This paper considers two methods of automated analysis of membrane residual stress in glass sheets, based on the phase-shifting concept in monochromatic light. In particular these methods are the automated versions of goniometric compensation methods of Tardy and Sénarmont. The proposed methods can effectively replace manual methods of compensation (goniometric compensation of Tardy and Sénarmont, Babinet and Babinet-Soleil compensators) provided by current standards on the analysis of residual stresses in glasses.

  11. Residual stress measurement by x-ray under the consideration of its penetration depth

    International Nuclear Information System (INIS)

    Doi, Osamu; Ukai, Takayoshi

    1983-01-01

    The authors derived the fundamental relations between the measured stress by X-ray and the residual stress distribution from the consideration of the contribution of internal stress in definite subsurface layer of metal to X-ray diffraction and proposed the exact formulas and their applications of residual stress measurements by successive thin layer removal in a plate, a hollow cylinder and a hollow sphere. (author)

  12. On using residual risk to assess the cost effectiveness and health protectiveness of remedy selection at superfund sites

    International Nuclear Information System (INIS)

    Katsumata, Peter T.; Kastenberg, William E.

    1998-01-01

    This article examines the importance of determining residual risk and its impact on remedy selection at Superfund Sites. Within this examination, risks are assessed using probabilistic models that incorporate the uncertainty and variability of the input parameters, and utilize parameter distributions based on current and applicable site-specific data. Monte Carlo methods are used to propagate these uncertainties and variabilities through the risk calculations resulting in a distribution for the estimate of both risk and residual risk. Such an approach permits an informed decision based on a broad information base which involves considering the entire uncertainty distribution of risk rather than a point estimate for each exposure scenario. Using the probabilistic risk estimates, with current and applicable site-specific data, alternative decisions regarding cleanup are obtained for two Superfund Sites

  13. Residual stress measurement in veneering ceramic by hole-drilling.

    Science.gov (United States)

    Mainjot, Amélie K; Schajer, Gary S; Vanheusden, Alain J; Sadoun, Michaël J

    2011-05-01

    Mismatch in thermal expansion properties between veneering ceramic and metallic or high-strength ceramic cores can induce residual stresses and initiate cracks when combined with functional stresses. Knowledge of the stress distribution within the veneering ceramic is a key factor for understanding and predicting chipping failures, which are well-known problems with Yttria-tetragonal-zirconia-polycrystal based fixed partial dentures. The objectives of this study are to develop a method for measuring the stress profile in veneering ceramics and to compare ceramic-fused-to-metal compounds to veneered Yttria-tetragonal-zirconia-polycrystal ceramic. The hole-drilling method, often used for engineering measurements, was adapted for use with veneering ceramic. Because of the high sensitivity needed in comparison with industrial applications, a high sensitivity electrical measurement chain was developed. All samples exhibited the same type of stress vs. depth profile, starting with compressive at the ceramic surface, decreasing with depth and becoming tensile at 0.5-1.0mm from the surface, and then becoming slightly compressive again. The zirconia samples exhibited a stress depth profile of larger magnitude. The hole drilling method was shown be a practical tool for measuring residual stresses in veneering ceramics. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Residual stress measurements in thick structural weldments by means of neutron diffraction

    International Nuclear Information System (INIS)

    Ohms, C.; Youtsos, A.G.; Idsert, P. v.d.; Timke, T.

    2000-01-01

    Welding residual stresses in large structural components are a major concern with respect to their performance and lifetime. In large structures reasonable thermal stress relief treatment is usually impossible due to the component size. On the other hand, prediction of welding stresses by numerical modelling has not yet proven to be generally reliable, while the experimental determination of such stresses remains a demanding task. At the high flux reactor (HFR), Petten, a new residual stress diffractometer has been installed recently capable of handling of components up to 1000 kg - the large component neutron diffraction facility (LCNDF). It has facilitated residual stress measurements in two large welded components, of which results are presented here. The first component represents a bi-metallic weld in form of a pipe of 25 mm wall thickness. Three dimensional measurements of residual stress are discussed in detail. The second specimen is a 66 mm wall thickness austenitic steel nuclear piping weld. Results on relief of strain within the weld through post weld heat treatment (PWHT) are presented. Additionally results obtained earlier at former CRNL (CAN) on a section of a thick nuclear piping weld are presented in order to illustrate the variation in the reference lattice parameter trough the weld and the heat affected zone (HAZ). These results clearly show the necessity to determine the reference parameters for each location in all measurement directions by means of measurements in small coupons free of macro-stresses. (orig.)

  15. Residual stress measurements by means of neutron diffraction

    International Nuclear Information System (INIS)

    Pintschovius, L.; Jung, V.; Macherauch, E.; Voehringer, O.

    1983-01-01

    A new method for the analysis of multiaxial residual stress states is presented, which is based on high resolution neutron diffraction. It is analogous to X-ray stress analysis, but the use of neutrons instead of X-rays allows the analysis of the stress distributions also in the interior of technical components in a non-destructive way. To prove the feasibility of the method, investigations of the loading stress distributions of an aluminium bar subjected to purely elastic bending were performed. Limiting factors due to the volume of the internal probe region and the sample thickness are discussed. Complete neutron residual stress analyses were carried out for a plastically deformed bending bar and a transformation-free water-quenched steel cylinder. The results are in fairly good agreement with theoretical expectations and with X-ray control measurements at the surface of the objects. (Auth.)

  16. Residual stress measurement method in MEMS microbeams using frequency shift data

    International Nuclear Information System (INIS)

    Somà, Aurelio; Ballestra, Alberto

    2009-01-01

    The dynamical behaviour of a set of gold microbeams affected by residual stress has been studied. Experimental frequency shift curves were obtained by increasing the dc voltage applied to the specimens. Comparison with different analytical and numerical models has been carried out in order to identify both analytical and finite element models in the presence of residual stress. Residual strain and stress, due to the fabrication process, have been widely reported in the literature in both out-of-plane microcantilevers and clamped–clamped microbeams by using mainly the value of pull-in voltage and static deflection data. In the case of a microcantilever, an accurate modelling includes the effect of the initial curvature due to microfabrication. In double-clamped microbeams, a pre-load applied by tensile stress is considered. A good correspondence is pointed out between measurements and numerical models so that the residual stress effect can be evaluated for different geometrical configurations

  17. Measurement of the residual stress distribution in a thick pre-stretched aluminum plate

    Science.gov (United States)

    Yuan, S. X.; Li, X. Q.; M, S.; Zhang, Y. C.; Gong, Y. D.

    2008-12-01

    Thick pre-stretched aluminum alloy plates are widely used in aircraft, while machining distortion caused by initial residual stress release in thick plates is a common and serious problem. To reduce the distortion, the residual stress distribution in thick plate must be measured. According to the characteristics of the thick pre-stretched aluminum alloy plate, based the elastic mechanical theory, this article deduces the modified layer-removal strain method adapting two different strain situations, which are caused by tensile and compressive stress. To validate this method, the residual stresses distribution along the thick direction of plate 2D70T351 is measured by this method, it is shown that the new method deduced in this paper is simple and accurate, and is very useful in engineering.

  18. Assessing the residual risk for transfusion-transmitted infections in the Philippine blood supply.

    Science.gov (United States)

    Lam, Hilton Y; Belizario, Vicente Y; Juban, Noel R; Alejandria, Marissa M; Castillo-Carandang, Nina; Arcellana-Nuqui, Elizabeth; Mirasol, Ma Angelina; Cordero, Cynthia P; Sison, Olivia T; Rivera, Adovich S

    2014-09-01

    Due to a USAID-funded study on blood banks, a national policy was instituted in 1994 that set standards for Philippine blood services, promoted voluntary donation, and led to a ban on commercial blood banks. In this follow-up study, we assess the safety of the supply by determining the residual risk for transfusion-transmitted infections (syphilis, hepatitis B and C, HIV). We also identified unsafe facility practices and generated policy recommendations. A 1992 study found that transfusion-ready blood was not safe using the LQAS method (P > 0.05). We found that the 2012 residual risk became 0 to 0.9 percent attributable to the national policy. We noted poor to fair adherence to this policy. We identified unsafe practices such as use of rapid tests and lack of random blood retesting. Training and use of regional networks may improve safety. Despite improvement in safety, facilities complain of funding and logistical issues regarding compliance with the policy.

  19. Residual stresses measurement by using ring-core method and 3D digital image correlation technique

    International Nuclear Information System (INIS)

    Hu, Zhenxing; Xie, Huimin; Zhu, Jianguo; Wang, Huaixi; Lu, Jian

    2013-01-01

    Ring-core method/three-dimensional digital image correlation (3D DIC) residual stresses measurement is proposed. Ring-core cutting is a mechanical stress relief method, and combining with 3D DIC system the deformation of the specimen surface can be measured. An optimization iteration method is proposed to obtain the residual stress and rigid-body motion. The method has the ability to cut an annular trench at a different location out of the field of view. A compression test is carried out to demonstrate how residual stress is determined by using 3D DIC system and outfield measurement. The results determined by the approach are in good agreement with the theoretical value. Ring-core/3D DIC has shown its robustness to determine residual stress and can be extended to application in the engineering field. (paper)

  20. Development of an on-site measurement method for residual stress in primary system piping of nuclear power plants

    International Nuclear Information System (INIS)

    Maekawa, Akira; Takahashi, Shigeru; Fujiwara, Masaharu

    2014-01-01

    In residual stress measurement for large-scale pipes and vessels in high radiation areas and highly contaminated areas of nuclear plants, it is difficult to bring the radioactivated pipes and vessels out of the areas as they are. If they can brought out, it is very burdensome to handle them for the measurement. Development of an on-site measurement method of residual stress which can be quickly applied and has sufficient measurement accuracy is desirable. In this study, a new method combining an electric discharge skim-cut method with a microscopic strain measurement method using markers was proposed to realize the on-site residual stress measurement on pipes in high radiation areas and highly contaminated areas. In the electric discharge skim-cut method, a boat-type sample is skimmed out of a pipe outer/inner surface using electric discharge machining and released residual stress is measured. The on-site measurement of residual stress by the method can be done using a small, portable electric discharge machine. In the microscopic strain measurement method using markers, the residual stress is estimated by microscopic measurement of the distance between markers after the stress release. The combination of both methods can evaluate the residual stress with the same accuracy as conventional methods offer and it can achieve reduction of radiation exposure in the measurement because the work is done simply and rapidly. In this study, the applicability of the electric discharge skim-cut method was investigated because the applicability of the microscopic strain measurement method using markers was confirmed previously. The experimental examination clarified the applicable conditions for the residual stress measurement with the same accuracy as the conventional methods. Furthermore, the electric discharge machining conditions using pure water as the machining liquid was found to eliminate the amount of liquid radioactive waste completely. (author)

  1. Veterinary antibiotic resistance, residues, and ecological risks in environmental samples obtained from poultry farms, Egypt.

    Science.gov (United States)

    Dahshan, Hesham; Abd-Elall, Amr Mohamed Mohamed; Megahed, Ayman Mohamed; Abd-El-Kader, Mahdy A; Nabawy, Ehab Elsayed

    2015-02-01

    In Egypt, poultry production constitutes one of the main sources of pollution with veterinary antibiotics (VAs) into the environment. About 80 % of meat production in Egypt is of poultry origin, and the potential environmental risks associated with the use of VAs in these farms have not yet been properly evaluated. Thus, the main purpose of this research was to evaluate the prevalence of antibiotic-resistant enteric key bacteria and the incidence of residual antibiotics in poultry farm environmental samples and to determine whether fertilizing soils with poultry litter from farms potentially brings ecological risks. From December 2011 to September 2012, a total of 225 litter, bird dropping, and water samples were collected from 75 randomly selected boiler poultry farms. A high prevalence of Escherichia coli (n = 179; 79.5 %) in contrast to the low prevalence of Salmonella spp. (n = 7; 3.1 %) was detected. Amongst E. coli isolates, serotypes O142:K86, O125:K70, O91:K, and O119:K69 were the most common. Meanwhile, Salmonella enterica serotypes emek and enteritidis were recovered. The antibiograms using the disc diffusion method revealed significantly more common resistant and multi-resistant isolates in broiler poultry farms. Residues of tetracycline and ciprofloxacin were detected at 2.125 and 1.401 mg kg(-1) mean levels, respectively, in environmental samples contaminated with E. coli-resistant strains by HPLC. The risk evaluations highlighted that tetracycline residues in poultry litter significantly display environmental risks with a hazard quotient value above 1 (1.64). Our study implies that ineffective implementation of veterinary laws which guide and guard against incorrect VA usage may potentially bring health and environmental risks.

  2. Principles of the measurement of residual stress by neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Webster, G A; Ezeilo, A N [Imperial Coll. of Science and Technology, London (United Kingdom). Dept. of Mechanical Engineering

    1996-11-01

    The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a suitable sampling volume, type of detector and alignment procedure. Methods of achieving a stress free reference are also considered. A selection of practical examples is included to demonstrate the success of the technique. (author) 14 figs., 1 tab., 18 refs.

  3. Principles of the measurement of residual stress by neutron diffraction

    International Nuclear Information System (INIS)

    Webster, G.A.; Ezeilo, A.N.

    1996-01-01

    The presence of residual stresses in engineering components can significantly affect their load carrying capacity and resistance to fracture. In order to quantify their effect it is necessary to know their magnitude and distribution. Neutron diffraction is the most suitable method of obtaining these stresses non-destructively in the interior of components. In this paper the principles of the technique are described. A monochromatic beam of neutrons, or time of flight measurements, can be employed. In each case, components of strain are determined directly from changes in the lattice spacings between crystals. Residual stresses can then be calculated from these strains. The experimental procedures for making the measurements are described and precautions for achieving reliable results discussed. These include choice of crystal planes on which to make measurements, extent of masking needed to identify a suitable sampling volume, type of detector and alignment procedure. Methods of achieving a stress free reference are also considered. A selection of practical examples is included to demonstrate the success of the technique. (author) 14 figs., 1 tab., 18 refs

  4. Risk Analysis on Organochlorine Pesticides Residue in Potato and Carrot from Conventional and Organic Farms in Citarum Watershed Area, West Java Province, Indonesia

    Directory of Open Access Journals (Sweden)

    Suphia Rahmawati

    2017-03-01

    Full Text Available Six samples of carrot and potatoes were collected from conventional and organic farms. Organochlorine pesticides (OCPs residue was analyzed using liquid-liquid extraction. The concentration of OCPs residue together with the consumption pattern were used to calculate the potential risk. Estimated Daily Intake (EDI of OCPs residue in carrots and potatoes both from conventional and organic farms were below the standard given in SNI 7313:2008 and the Maximum Residue Limit (MRLs from USEPA . Hazard quotient (HQ and Hazard Index (HI as effect analysis were below the unity, thus there may not be a concern for non-carcinogenic effect. Risk analysis on cancer effects indicated that potatoes samples were above the recommended risk by EPA (10-6. In addition, risk of potatoes samples from organic samples was higher compare to that of the conventional farm. Cancer risk analysis of carrot samples were found below the recommended risk by EPA. Cancer risk effect of carrot samples from conventional farm was slightly higher compare to that of the organic farm.

  5. Measurement of residual stress in plasma-sprayed metallic, ceramic and composite coatings

    Energy Technology Data Exchange (ETDEWEB)

    Kesler, O.; Suresh, S. [Massachusetts Inst. of Tech., Cambridge, MA (United States); Matejicek, J.; Sampath, S. [State Univ. of New York, Stony Brook, NY (United States). Inst. for Mathematical Sciences; Gnaeupel-Herold, T.; Brand, P.C.; Prask, H.J. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1998-12-15

    Residual stresses in plasma-sprayed coatings were studied by three experimental techniques: curvature measurements, neutron diffraction and X-ray diffraction. Two distinct material classes were investigated: (1) single-material coatings (molybdenum) and (2) bi-material composites (nickel+alumina and NiCrAlY+yttria-stabilized zirconia), with and without graded layers. This paper deals with the effects of coating thickness and material properties on the evolution of residual stresses as a function of composition and thickness in both homogeneous and graded coatings. Mathematical analysis of the results allowed in some cases the separation of the quenching stress and thermal stress contributions to the final residual stress, as well as the determination of the through-thickness stress profile from measurements of different thickness specimens. In the ceramic-metal composites, it was found that the quenching stress plays a dominant role in the metallic phase, whereas the stress in the ceramic phase is mostly dominated by thermal mismatch. The respective thermal expansion coefficients and mechanical properties are the most important factors determining the stress sign and magnitude. The three residual stress measurement methods employed here were found to be complementary, in that each can provide unique information about the stress state. The most noteworthy outcomes are the determination of the through-thickness stress profile in graded coatings with high spatial resolution (curvature method) and determination of stress in each phase of a composite separately (neutron diffraction). (orig.) 25 refs.

  6. Prediction of residual stress distribution in multi-stacked thin film by curvature measurement and iterative FEA

    International Nuclear Information System (INIS)

    Choi, Hyeon Chang; Park, Jun Hyub

    2005-01-01

    In this study, residual stress distribution in multi-stacked film by MEMS (Micro-Electro Mechanical System) process is predicted using Finite Element Method (FEM). We develop a finite element program for REsidual Stress Analysis (RESA) in multi-stacked film. The RESA predicts the distribution of residual stress field in multi-stacked film. Curvatures of multi-stacked film and single layers which consist of the multi-stacked film are used as the input to the RESA. To measure those curvatures is easier than to measure a distribution of residual stress. To verify the RESA, mean stresses and stress gradients of single and multilayers are measured. The mean stresses are calculated from curvatures of deposited wafer by using Stoney's equation. The stress gradients are calculated from the vertical deflection at the end of cantilever beam. To measure the mean stress of each layer in multi-stacked film, we measure the curvature of wafer with the film after etching layer by layer in multi-stacked film

  7. Residual stress measurement in socket welded joints by neutron diffraction

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Ishiwata, Masayuki; Minakawa, Noriaki; Funahashi, Satoru.

    1995-01-01

    Neutron diffraction measurements of lattice spacings provide the spatial map of residual stress near welds in ferritic steel socket joints. The high tensile stress greater than 200 MPa was found in the fusion and heat-affected zones in the hoop direction. However, the highest tensile stress in the axial direction at the weld root was about 110 MPa relatively lower than the expected value from the fatigue test results. The balancing compressive stress was found near the surface of the socket weld fusion zone. Heat treatment at 625degC for 2 hours was sufficient for the relief of residual stress in socket welds. (author)

  8. Residual diesel measurement in sand columns after surfactant/alcohol washing

    International Nuclear Information System (INIS)

    Martel, R.; Gelinas, P.J.

    1996-01-01

    A new simple gravimetric technique has been designed to determine residual oil saturation of complex hydrocarbon mixtures (e.g., diesel) in sand column experiments because reliable methods are lacking. The He/N 2 technique is based on drying of sand columns by circulating helium gas to drag oil droplets in a cold trap (liquid nitrogen). With this technique, residual diesel measurement can be performed easily immediately after alcohol/surfactant washing and in the same lab. For high residual diesel content in Ottawa sand (25 to 30 g/kg), the technique is much more accurate (± 2% or 600 mg/kg) than the standard analytical methods for the determination of mineral oil and grease. The average relative error on partial diesel dissolution in sand column estimated after alcohol/surfactant flooding (residual saturation of 10 to 15 g/kg) is as low as 5%. The precision of the He/N 2 technique is adequate to compare relative efficiency of washing solutions when partial extraction of residual oil in Ottawa sand columns is performed. However, this technique is not adapted for determination of traces of oil in sediment or for environmental control of contaminated soils. Each diesel determination by the He/N 2 technique costs less than $8 in chemical products (helium and liquid nitrogen). A simple laboratory drying setup can be built for less than $400 which makes this technique valuable for diesel analyses when a large number of tests are required

  9. Assessment of Dithiocarbamate Residues on Tomatoes Conventionally Grown in Uganda and the Effect of Simple Washing to Reduce Exposure Risk to Consumers

    DEFF Research Database (Denmark)

    Atuhaire, Aggrey; Kaye, Emmanuel; Mutambuze, Innocent Louis

    2017-01-01

    Pesticide misuse by farmers poses health risks to consumers. This study assessed the level of dithiocarbamate residues in tomatoes acquired from 20 farmers and 25 market vendors in Wakiso District, how simple washing affects these residues, and the potential chronic health risk for Ugandans eatin...

  10. FIB-based measurement of local residual stresses on microsystems

    Science.gov (United States)

    Vogel, Dietmar; Sabate, Neus; Gollhardt, Astrid; Keller, Juergen; Auersperg, Juergen; Michel, Bernd

    2006-03-01

    The paper comprises research results obtained for stress determination on micro and nanotechnology components. It meets the concern of controlling stresses introduced to sensors, MEMS and electronics devices during different micromachining processes. The method bases on deformation measurement options made available inside focused ion beam equipment. Removing locally material by ion beam milling existing stresses / residual stresses lead to deformation fields around the milled feature. Digital image correlation techniques are used to extract deformation values from micrographs captured before and after milling. In the paper, two main milling features have been analyzed - through hole and through slit milling. Analytical solutions for stress release fields of in-plane stresses have been derived and compared to respective experimental findings. Their good agreement allows to settle a method for determination of residual stress values, which is demonstrated for thin membranes manufactured by silicon micro technology. Some emphasis is made on the elimination of main error sources for stress determination, like rigid body object displacements and rotations due to drifts of experimental conditions under FIB imaging. In order to illustrate potential application areas of the method residual stress suppression by ion implantation is evaluated by the method and reported here.

  11. Leaching characteristics of calcium-based compounds in MSWI Residues: From the viewpoint of clogging risk.

    Science.gov (United States)

    Xia, Yi; Zhang, Hua; Phoungthong, Khamphe; Shi, Dong-Xiao; Shen, Wen-Hui; Shao, Li-Ming; He, Pin-Jing

    2015-08-01

    Leachate collection system (LCS) clogging caused by calcium precipitation would be disadvantageous to landfill stability and operation. Meanwhile, calcium-based compounds are the main constituents in both municipal solid waste incineration bottom ash (MSWIBA) and stabilized air pollution control residues (SAPCR), which would increase the risk of LCS clogging once these calcium-rich residues were disposed in landfills. The leaching behaviors of calcium from the four compounds and municipal solid waste incineration (MSWI) residues were studied, and the influencing factors on leaching were discussed. The results showed that pH was the crucial factor in the calcium leaching process. CaCO3 and CaSiO3 began leaching when the leachate pH decreased to less than 7 and 10, respectively, while Ca3(PO4)2 leached at pHleaching rate for the different calcium-based compounds is as follows: CaSiO3>Ca3(PO4)2>CaCO3. The calcium leaching from the MSWIBA and SAPCR separately started from pHleaching respectively, which was proven by the X-ray diffraction results. Based on the leaching characteristics of the different calcium compounds and the mineral phase of calcium in the incineration residues, simulated computation of their clogging potential was conducted, providing the theoretical basis for the risk assessment pertaining to LCS clogging in landfills. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Residual risks of the 13th amendment to the German Atomic Energy Act

    International Nuclear Information System (INIS)

    Schneider, Horst

    2011-01-01

    The 13th amendment to the German Atomic Energy Act, which was adopted by the German federal parliament on June 30 and entered into force on August 6, 2011, must be judged in the light of its genesis. Federal Chancellor Merkel, in her government declaration of June 9, 2011, had mentioned topics such as residual risk, safety standards, and risk assumptions, on which the federal government, in the week after the event of March 11, 2011, had commissioned the Advisory Committee on Reactor Safeguards (RSK) to conduct a comprehensive safety review of all German nuclear power plants, and appointed an Ethics Committee to write an opinion on safe energy supply. On the basis of quickly drafted reports, the federal cabinet, without any international harmonization (EU, IEA), adopted a draft opt out law on June 6, 2011. How should the declarations by the Federal Chancellor on June 9, 2011 be classified in terms of atomic energy law? In her words, it all revolved around the residual risk. The debate, which has been shifted to the realm of constitutional law, is open to considerations and steps to attack the new opt out law on grounds of material unconstitutionality (violation of the property guarantee under Sec. 14 or the principle of equality under Art.3 of the Basic Law). As far as final storage is concerned, the amendment to the German Atomic Energy Act announced still for this year, also for transposition of the EURATOM Directive of July 19, 2011 about nuclear waste management, the ''re-assessment of the residual risk'' is not likely to play a role. All these events are reminiscent of a sentence by former Federal Chancellor Schmidt: ''The history of the NATO dual-track decision remains a textbook case showing that even in a democracy emotions using ethical arguments, mixed with demagogy, can become strong enough to cast aside balanced reason.'' There is also a distinction by Max Weber between ''ethics of ideology'' and ''ethics of responsibility''. (orig.)

  13. Pesticides in persimmons, jujubes and soil from China: Residue levels, risk assessment and relationship between fruits and soils.

    Science.gov (United States)

    Liu, Yihua; Li, Shiliang; Ni, Zhanglin; Qu, Minghua; Zhong, Donglian; Ye, Caifen; Tang, Fubin

    2016-01-15

    Extreme and uncontrolled usage of pesticides produces a number of problems for vegetation and human health. In this study, the existence of organophosphates (OPs), organochlorines (OCs), pyrethroids (PYs) and fungicides (FUs) were investigated in persimmons/jujubes and their planted soils, which were collected from China. One OP (dimethoate), three OCs (DDT, quintozene and aldrin), six PYs (bifenthrin, fenpropathrin, cyhalothrin, cypermethrin, fenvalerate and deltamethrin) and two FUs (triadimefon and buprofezin) were found in 36.4% of persimmons and 70.8% of jujubes, with concentrations from 1.0 μg/kg to 2945.0 μg/kg. The most frequently detected pesticides in the two fruits were fenpropathrin in persimmons and cypermethrin in jujubes, with the detection frequencies of 30.0% and 22.7%, respectively. The residues of 4.5% (persimmon) and 25.0% (jujube) of samples were higher than the maximum residue limits (MRLs) of China. Compared with the fruits, more types of pesticides and higher residues were observed in their planted soils. The most frequently detected pesticides were HCH in persimmon soil and DDT in jujube soil, with the detection frequencies of 10.9% and 12.7%, respectively. For the tested samples, 39.1% of fruit samples and 63.0% of soil samples with multiple residues (containing more than two pesticides) were noted, even up to 8 residues in fruits and 14 residues in soils. Except for cyhalothrin, the other short-term risks for the tested pesticides in the fruits were below 10%, and the highest long-term risk was 14.13% for aldrin and dieldrin. There was no significant health risk for consumers via consumption of the two fruits. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Residual stress measurement of EB-welded plates with contour method. Part 2: FEM analysis of contour profiles

    International Nuclear Information System (INIS)

    Romppanen, A.-J.; Immonen, E.

    2013-12-01

    The residual stresses formed as a result of Electronic Beam welding (EB-welding) in copper are investigated by Posiva. In the present study, residual stresses of EB-welded copper plates were studied with contour method. In the method eleven copper plates (X436 - X440 and X453 - X458) were cut in half with wire electric discharge machining (EDM) after which the deformation due to stress relaxation was measured with coordinate measurement system. The measured data was then used as boundary displacement data for the FEM analyses, in which the corresponding residual stresses were calculated. Before giving the corresponding displacement boundary conditions to the FE models, the deformation data was processed and smoothed appropriately. The residual stress levels of the copper plates were found to be around 40 - 55 MPa at maximum. This corresponds to other reported residual stress measurements and current state of knowledge with this material in Posiva. (orig.)

  15. Process for measuring residual stresses

    International Nuclear Information System (INIS)

    Elfinger, F.X.; Peiter, A.; Theiner, W.A.; Stuecker, E.

    1982-01-01

    No single process can at present solve all problems. The complete destructive processes only have a limited field of application, as the component cannot be reused. However, they are essential for the basic determination of stress distributions in the field of research and development. Destructive and non-destructive processes are mainly used if investigations have to be carried out on original components. With increasing component size, the part of destructive tests becomes smaller. The main applications are: quality assurance, testing of manufactured parts and characteristics of components. Among the non-destructive test procedures, X-raying has been developed most. It gives residual stresses on the surface and on surface layers near the edges. Further development is desirable - in assessment - in measuring techniques. Ultrasonic and magnetic crack detection processes are at present mainly used in research and development, and also in quality assurance. Because of the variable depth of penetration and the possibility of automation they are gaining in importance. (orig./RW) [de

  16. VALUE AT RISK - CORPORATE RISK MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Anis Cecilia-Nicoleta

    2011-12-01

    Full Text Available The notion of 'risk' is used in a number of sciences. The Faculty of Law studies the risk depending on its legality. The Accident Theory applies this term to describe the damage and the disasters. One can find studies on the risks in the works of psychology, philosophy, medicine and within each of these areas the study of the risk is based on the given science subject and, of course, on their methods and approaches. Such a variety of risk study is explained by the diversity of this phenomenon. Under the market economy conditions, the risk is an essential component of any economic agent management policy, of the approach developed by this one, a strategy that depends almost entirely on individual ability and capacity to anticipate his evolution and to exploit his opportunities, assuming a so-called 'risk of business failure.' There are several ways to measure the risks in projects, one of the most used methods to measure this being the Value at Risk(VaR. Value at Risk (VaR was made famous by JP Morgan in the mid 1990s, by introducing the RiskMetrics approach, and hence, by far, has been sanctioned by several Governing Bodies throughout the world bank. In short, it measures the value of risk capital stocks in a given period at a certain probability of loss. This measurement can be modified for risk applications through, for example, the potential loss values affirmation in a certain amount of time during the economic life of the project- clearly, a project with a lower VaR is better. It should be noted that it is not always possible or advisable for a company to limit itself to the remote analysis of each risk because the risks and their effects are interdependent and constitute a system .In addition, there are risks which, in combination with other risks, tend to produce effects which they would not have caused by themselves and risks that tend to offset and even cancel each other out.

  17. Measurement of residual stress in a sphere by x-ray under the consideration of its penetration depth

    International Nuclear Information System (INIS)

    Doi, Osamu; Ukai, Takayoshi

    1981-01-01

    It was pointed out in the case of a plate that when stress gradient is large, the use of the X-ray with large penetration depth caused large measurement error. In this paper, the theoretical equations for measuring the residual stress in a sphere with X-ray, taking penetration depth into account, are proposed, and the example of application is shown. As the method of measuring the residual stress in a hollow sphere with X-ray, only the method of combining external surface removal and external surface irradiation is practically in use. It was assumed that a sphere is isotropic, and that the residual stress is a function of the radius only. First, the theory of measuring the residual stress in a sphere with X-ray taking penetration depth into account is explained, and the equations for calculating the residual stresses in tangential and radial directions are derived. As the example of applying this theory, the distribution of the residual stress in a steel ball for a ball bearing was measured with Cr characteristic X-ray. The ball of 30 mm diameter was made of high-carbon chromium bearing steel, grade 2, (JIS SUJ2) and quenched and tempered. The removal of the thin layer was made by chemical etching and electrolysis. The measured values and the calculated values are shown. (Kako, I.)

  18. Bioaccessibility and health risk of heavy metals in ash from the incineration of different e-waste residues.

    Science.gov (United States)

    Tao, Xiao-Qing; Shen, Dong-Sheng; Shentu, Jia-Li; Long, Yu-Yang; Feng, Yi-Jian; Shen, Chen-Chao

    2015-03-01

    Ash from incinerated e-waste dismantling residues (EDR) may cause significant health risks to people through ingestion, inhalation, and dermal contact exposure pathways. Ashes of four classified e-waste types generated by an incineration plant in Zhejiang, China were collected. Total contents and the bioaccessibilities of Cd, Cu, Ni, Pb, and Zn in ashes were measured to provide crucial information to evaluate the health risks for incinerator workers and children living in vicinity. Compared to raw e-waste in mixture, ash was metal-enriched by category incinerated. However, the physiologically based extraction test (PBET) indicates the bioaccessibilities of Ni, Pb, and Zn were less than 50 %. Obviously, bioaccessibilities need to be considered in noncancer risk estimate. Total and PBET-extractable contents of metal, except for Pb, were significantly correlated with the pH of the ash. Noncancer risks of ash from different incinerator parts decreased in the order bag filter ash (BFA) > cyclone separator ash (CFA) > bottom ash (BA). The hazard quotient for exposure to ash were decreased as ingestion > dermal contact > inhalation. Pb in ingested ash dominated (>80 %) noncancer risks, and children had high chronic risks from Pb (hazard index >10). Carcinogenic risks from exposure to ash were under the acceptable level (incinerated ash are made.

  19. The risks of measuring risk

    International Nuclear Information System (INIS)

    Berg, G.G.

    1982-01-01

    The author gives an overview of the Thirteenth Rochester International Conference on Environmental Toxicity, which examined both the logical soundness of the inference of risk and the validity of the environmental evidence of damage. Examples are itemized, concise introductions are given for each published paper in the proceedings, and an appropriate keynote is given by way of stating the established and alternate approach to risk measurement. The volume is described as ''more than a review of advance in measurement of risks to health . . . (but also) a landmark of a change in scientific opinion.''

  20. 78 FR 66107 - National Emissions Standards for Hazardous Air Pollutants Residual Risk and Technology Review for...

    Science.gov (United States)

    2013-11-04

    ... estimate VCS voluntary consensus standards WWW world wide web Organization of this Document. The... oxidizer RTR residual risk and technology review SAB Science Advisory Board SBA Small Business... acceptable in the world in which we live'' (Risk Report at 178, quoting NRDC v. EPA, 824 F.2d 1146, 1165 (D.C...

  1. Measurement of residual stress in plasma-sprayed composite coatings with graded and uniform compositions

    Energy Technology Data Exchange (ETDEWEB)

    Kesler, O.; Suresh, S. [Massachusetts Inst. of Tech., Cambridge, MA (United States); Matejicek, J.; Sampath, S.

    1999-10-01

    Residual stresses in plasma sprayed composite coatings were studied experimentally by both curvature and neutron diffraction measurements. Graded and uniform composite coatings, consisting of nickel + alumina and NiCrAlY + yttria-stabilized zirconia, were investigated. This paper briefly summarizes our recent work dealing with the effects of coating thickness, composition, and material properties on the evolution of residual stresses in coatings. Analysis of the results allowed in some cases the separation of the quenching stress and thermal stress contributions to the final residual stress, as well as the determination of the through-thickness stress profile from measurements of different thickness specimens. In the ceramic-metal composites, it was found that the thermal mismatch stress plays a dominant role in the ceramic phase, whereas the stress in the metallic phase is mostly dominated by quenching stress. The residual stress measurement methods employed here were found to be complementary, in that each can provide unique information about the stress state. Through-thickness stress profiles in graded coatings were determined with high spatial resolution by the curvature method, and determination of the stress in each separate phase of a composite was made by neutron diffraction. (orig.) 14 refs.

  2. Neutron diffraction measurements of residual stresses in NPP construction materials

    International Nuclear Information System (INIS)

    Hinca, R.; Bokuchava, G.

    2001-01-01

    Neutron diffraction is one of the most powerful methods for condensed matter studies. This method is used for non-destructive determination of residual stresses in material. The fundamental aspects of neutron diffraction are discussed, together with a brief description of the experimental facility. The principal advantage of using neutrons rather than the more conventional X-rays is the fact that neutron can penetrate deeply (2-4 cm for steel and more than 10 cm for aluminium) into metals to determine internal parameters within the bulk of materials. We present results of measurements residual stresses in NPP construction material - austenitic stainless steel (Cr-18%, Ni-10%, Ti-1%) coated with high-nickel alloy. (authors)

  3. Residual stress measurement using the pulsed neutron source at LANSCE

    International Nuclear Information System (INIS)

    Bourke, M.A.M.; Goldstone, J.A.; Holden, T.M.

    1991-01-01

    The presence of residual stress in engineering components can effect their mechanical properties and structural integrity. Neutron diffraction is the only measuring technique which can make spatially resolved non-destructive strain measurements in the interior of components. By recording the change in the crystalline interplanar spacing, elastic strains can be measured for individual lattice reflections. Using a pulsed neutron source, all the lattice reflections are recorded in each measurement which allows anisotropic effects to be studied. Measurements made at the Manuel Lujan Jr Neutron Scattering Centre (LANSCE) demonstrate the potential for stress measurements on a pulsed source and indicate the advantages and disadvantages over measurements made on a reactor. 15 refs., 7 figs

  4. Total gamma activity measurements for determining the radioactivity of residual materials from nuclear power stations

    International Nuclear Information System (INIS)

    Auler, I.; Meyer, M.; Stickelmann, J.

    1995-01-01

    Large amounts of residual materials from retrofitting measures and from decommissioning of nuclear power stations shows such a weak level of radioactivity that they could be released after decision measurements. Expenses incurred with complex geometry cannot be taken with common methods. NIS developed a Release Measurement Facility (RMF) based on total gamma activity measurements especially for these kind of residual materials. The RMF has been applied for decision measurements in different nuclear power plants. Altogether about 2,000 Mg of various types of materials have been measured up to now. More than 90 % of these materials could be released 0 without any restriction after decision measurements

  5. Residual sleep disturbance and risk of relapse during the continuation/maintenance phase treatment of major depressive disorder with the selective serotonin reuptake inhibitor fluoxetine

    Directory of Open Access Journals (Sweden)

    McGrath Patrick J

    2010-02-01

    Full Text Available Abstract Background Relapse of major depressive disorder (MDD is a common clinical problem. This study was designed to determine whether residual sleep disturbance (insomnia and hypersomnia predict risk of relapse during the continuation and maintenance treatment of MDD. Methods A total of 570 patients with MDD were treated with open-label, flexible dose fluoxetine (range 20 to 60 mg; mean dose = 45.8 mg/day; SD = 15.1 for 12 weeks. Under double blind conditions, 262 patients who achieved clinical response were randomly assigned to continue fluoxetine or to switch to placebo for 52 weeks or until relapse. Residual sleep disturbance during the baseline visit of the double-blind phase was assessed using items 4, 5, 6 (insomnia and 22, 23, 24 (hypersomnia of the Hamilton Depression Rating Scale (HDRS. Survival analysis was utilized to determine the effect of residual sleep disturbance on risk of relapse. Results The severities of early (P > 0.05, middle (P > 0.05, late (P > 0.05, or total (P > 0.05 residual insomnia were not found to significantly predict risk of relapse during continuation and maintenance-phase treatment. Similarly, the severities of early bedtime (P > 0.05, oversleeping (P > 0.05, napping (P > 0.05, or total (P > 0.05 residual hypersomnia were not found to significantly predict risk of relapse during continuation and maintenance-phase treatment. Conclusion The present study did not identify the severity of residual sleep disturbance among fluoxetine responders to predict risk of MDD relapse. The size of our sample may have precluded us from identifying more modest effects of residual sleep disturbance on the risk of relapse in MDD patients. Future studies are needed to further explore the relationship between residual sleep disturbance and relapse in MDD. Trial Registration ClinicalTrials.gov Identifier: NCT00427128

  6. Feasibility of ultrasonic and eddy current methods for measurement of residual stress in shot peened metals

    International Nuclear Information System (INIS)

    Lavrentyev, Anton I.; Stucky, Paul A.; Veronesi, William A.

    2000-01-01

    Shot peening is a well-known method for extending the fatigue life of metal components by introducing compressive residual stresses near their surfaces. The capability to nondestructively evaluate the near surface residual stress would greatly aid the assurance of proper fatigue life in shot-peened components. This paper presents preliminary results from a feasibility study examining the use of ultrasonic and eddy current NDE methods for residual stress measurement in components where the stress has been introduced by shot peening. With an ultrasonic method, a variation of ultrasonic surface wave speed with shot peening intensity was measured. Near surface conductivity was measured by eddy current methods. Since the effective penetration depth of both methods employed is inversely related to the excitation frequency, by making measurements at different frequencies, each method has the potential to provide the stress-depth profile. Experiments were conducted on aluminum specimens (alloy 7075-T7351) peened within the Almen peening intensity range of 4C to 16C. The experimental results obtained demonstrate a correlation between peening intensity and Rayleigh wave velocity and between peening intensity and conductivity. The data suggests either of the methods may be suitable, with limitations, for detecting unsatisfactory levels of shot peening. Several factors were found to contribute to the measured responses: surface roughness, near surface plastic deformation (cold work) and residual stress. The contribution of each factor was studied experimentally. The feasibility of residual stress determination from the measured data is discussed

  7. DERMAL AND MOUTHING TRANSFERS OF SURFACE RESIDUES MEASURED USING FLUORESCENCE IMAGING

    Science.gov (United States)

    To reduce the uncertainty associated with current estimates of children's exposure to pesticides by dermal contact and non-dietary ingestion, residue transfer data are required. Prior to conducting exhaustive studies, a screening study to develop and test methods for measuring...

  8. Measurement and prediction of residual stress in a bead-on-plate weld benchmark specimen

    International Nuclear Information System (INIS)

    Ficquet, X.; Smith, D.J.; Truman, C.E.; Kingston, E.J.; Dennis, R.J.

    2009-01-01

    This paper presents measurements and predictions of the residual stresses generated by laying a single weld bead on a flat, austenitic stainless steel plate. The residual stress field that is created is strongly three-dimensional and is considered representative of that found in a repair weld. Through-thickness measurements are made using the deep hole drilling technique, and near-surface measurements are made using incremental centre hole drilling. Measurements are compared to predictions at the same locations made using finite element analysis incorporating an advanced, non-linear kinematic hardening model. The work was conducted as part of an European round robin exercise, coordinated as part of the NeT network. Overall, there was broad agreement between measurements and predictions, but there were notable differences

  9. Measuring multiple residual-stress components using the contour method and multiple cuts

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Michael B [Los Alamos National Laboratory; Swenson, Hunter [Los Alamos National Laboratory; Pagliaro, Pierluigi [U. PALERMO; Zuccarello, Bernardo [U. PALERMO

    2009-01-01

    The conventional contour method determines one component of stress over the cross section of a part. The part is cut into two, the contour of the exposed surface is measured, and Bueckner's superposition principle is analytically applied to calculate stresses. In this paper, the contour method is extended to the measurement of multiple stress components by making multiple cuts with subsequent applications of superposition. The theory and limitations are described. The theory is experimentally tested on a 316L stainless steel disk with residual stresses induced by plastically indenting the central portion of the disk. The stress results are validated against independent measurements using neutron diffraction. The theory has implications beyond just multiple cuts. The contour method measurements and calculations for the first cut reveal how the residual stresses have changed throughout the part. Subsequent measurements of partially relaxed stresses by other techniques, such as laboratory x-rays, hole drilling, or neutron or synchrotron diffraction, can be superimposed back to the original state of the body.

  10. Leaching characteristics of calcium-based compounds in MSWI Residues: From the viewpoint of clogging risk

    International Nuclear Information System (INIS)

    Xia, Yi; Zhang, Hua; Phoungthong, Khamphe; Shi, Dong-Xiao; Shen, Wen-Hui; Shao, Li-Ming; He, Pin-Jing

    2015-01-01

    Highlights: • The leaching behavior of Ca-based compounds commonly in MSWI residues was studied. • pH is the crucial factor for calcium leaching process. • CaCO 3 was the most sensitive to leaching temperature and Ca 3 (PO 4 ) 2 was the least. • Ca leaching of MSWIBA and SAPCR attributed to CaCO 3 and Ca 3 (PO 4 ) 2 respectively. • Potential clogging ability of MSWI residues leachate in open air was calculated. - Abstract: Leachate collection system (LCS) clogging caused by calcium precipitation would be disadvantageous to landfill stability and operation. Meanwhile, calcium-based compounds are the main constituents in both municipal solid waste incineration bottom ash (MSWIBA) and stabilized air pollution control residues (SAPCR), which would increase the risk of LCS clogging once these calcium-rich residues were disposed in landfills. The leaching behaviors of calcium from the four compounds and municipal solid waste incineration (MSWI) residues were studied, and the influencing factors on leaching were discussed. The results showed that pH was the crucial factor in the calcium leaching process. CaCO 3 and CaSiO 3 began leaching when the leachate pH decreased to less than 7 and 10, respectively, while Ca 3 (PO 4 ) 2 leached at pH < 12. CaSO 4 could hardly dissolve in the experimental conditions. Moreover, the sequence of the leaching rate for the different calcium-based compounds is as follows: CaSiO 3 > Ca 3 (PO 4 ) 2 > CaCO 3 . The calcium leaching from the MSWIBA and SAPCR separately started from pH < 7 and pH < 12, resulting from CaCO 3 and Ca 3 (PO 4 ) 2 leaching respectively, which was proven by the X-ray diffraction results. Based on the leaching characteristics of the different calcium compounds and the mineral phase of calcium in the incineration residues, simulated computation of their clogging potential was conducted, providing the theoretical basis for the risk assessment pertaining to LCS clogging in landfills

  11. Measurement of residual stresses in welded sample of dissimilar materials

    International Nuclear Information System (INIS)

    Mansur, Tanius Rodrigues; Gomes, Paulo de Tarso Vida; Scaldaferri, Denis Henrique Bianchi; Martins, Geraldo Antonio Scoralick; Atanazio Filho, Nelson do Nascimento

    2008-01-01

    reactors, what can generate significant residual stresses due so much to the welding procedure as for the difference of the coefficients of thermal expansion of the involved materials. In this work, are shown the results of the measurement of residual tensions in welded sample of steel carbon SA 508 Cl 3 and stainless steel 316L. The Inconel 182 was used as weld metal. (author)

  12. Measuring Idiosyncratic Risk

    DEFF Research Database (Denmark)

    Sunesen, Eva Rytter

    This paper offers two refinements of the traditional risk measure based on the volatility of growth. First, we condition GDP growth on structural characteristics of the host country that move only slowly and therefore can be partly predicted by an investor. Second, we adjust conditional risk...... for the systematic components due to the global and regional interdependence between alternative investment locations. The decomposition of conditional risk into its systematic and idiosyncratic components reveals that not only are African countries on average characterised by a larger conditional risk than Asian...... and Latin American countries, but the idiosyncratic risk factor also represents a larger share than in other developing countries. As a final contribution, we search the empirical literature on foreign direct investment and risk in order to determine which of the suggested risk measures provide the best...

  13. Prevalence, Incidence, and Residual Risks for Transfusion Transmitted HIV-1/2 Infection among Chinese Blood Donors

    Science.gov (United States)

    Wang, Jingxing; Liu, Jing; Yao, Fuzhu; Wen, Guoxin; Li, Julin; Huang, Yi; Lv, Yunlai; Wen, Xiuqiong; Wright, David; Yu, Qilu; Guo, Nan; Ness, Paul; Shan, Hua

    2012-01-01

    Background There is little data on HIV prevalence, incidence or residual risks for transfusion transmitted HIV infection among Chinese blood donors. Methods Donations from five Chinese blood centers in 2008–2010 were screened using two rounds of ELISA testing for anti-HIV-1/2. A reactive result in either or both rounds led to Western Blot confirmatory testing. HIV prevalence and demographic correlates among first time donors, incidence rate and demographic correlates among repeat donors were examined. Weighted multivariable logistic regression analysis examined correlates of HIV confirmatory status among first time donors. Residual risks for transfusion transmitted HIV infection were evaluated based on incidence among repeat donors. Results Among 821,320 donations, 40% came from repeat donors.1,837 (0.34%) first time and 577 (0.17%) repeat donations screened reactive for anti-HIV-1/2, among which 1,310 and 419 were tested by Western Blot. 233 (17.7%) first time and 44 (10.5%) repeat donations were confirmed positive. Estimated prevalence was 66 infections per 100,000 (95% CI: 59–74) first time donors. Estimated incidence was 9/100,000 (95% CI: 7–12) person-years among repeat donors. Weighted multivariable logistic regression analysis indicate that first time donors 26–45 years old were 1.6–1.8 times likely to be HIV positive than those 25 years and younger. Donors with some college or above education were less likely to be HIV positive than those with middle school education, ORs ranging from 0.35 to 0.60. Minority were 1.6 times likely to be HIV positive than Han majority donors (OR: 1.6; CI: 1.2–2.1). No difference in prevalence was found between gender. Current HIV TTI residual risk was 5.4 (1.2–12.5) infections per million whole blood donations. Conclusion Despite the declining HIV epidemic China, estimated residual risks for transfusion transmitted HIV infection are still high, highlighting the potential blood safety yield of NAT implementation

  14. Non-destructive residual pressure self-measurement method for the sensing chip of optical Fabry-Perot pressure sensor.

    Science.gov (United States)

    Wang, Xue; Wang, Shuang; Jiang, Junfeng; Liu, Kun; Zhang, Xuezhi; Xiao, Mengnan; Xiao, Hai; Liu, Tiegen

    2017-12-11

    We introduce a simple residual pressure self-measurement method for the Fabry-Perot (F-P) cavity of optical MEMS pressure sensor. No extra installation is required and the structure of the sensor is unchanged. In the method, the relationship between residual pressure and external pressure under the same diaphragm deflection condition at different temperatures is analyzed by using the deflection formula of the circular plate with clamped edges and the ideal gas law. Based on this, the residual pressure under the flat condition can be obtained by pressure scanning process and calculation process. We carried out the experiment to compare the residual pressures of two batches MEMS sensors fabricated by two kinds of bonding process. The measurement result indicates that our approach is reliable enough for the measurement.

  15. Finite element analysis and measurement for residual stress of dissimilar metal weld in pressurizer safety nozzle mockup

    International Nuclear Information System (INIS)

    Lee, Kyoung Soo; Kim, W.; Lee, Jeong Geun; Park, Chi Yong; Yang, Jun Seok; Kim, Tae Ryong; Park, Jai Hak

    2009-01-01

    Finite element (FE) analysis and experiment for weld residual stress (WRS) in the pressurizer safety nozzle mockup is described in various processes and results. Foremost of which is the dissimilar simulation metal welding (DMW) between carbon steel and austenitic stainless steel. Thermal and structural analyses were compared with actual residual stress, and actual measurements of. Magnitude and distribution of WRS in the nozzle mockup were assessed. Two measurement methods were used: hole-drilling method (HDM) with strain gauge for residual stress on the surface of the mockup, and block removal and splitting layer (BRSL) method for through-thickness. FE analysis and measurement data showed good agreement. In conclusion, the characteristics of weld residual stress of DMW could be well understood and the simplified FE analysis was verified as acceptable for estimating WRS

  16. Finite element analysis and measurement for residual stress of dissimilar metal weld in pressurizer safety nozzle mockup

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Soo; Kim, W.; Lee, Jeong Geun; Park, Chi Yong; Yang, Jun Seok; Kim, Tae Ryong [Korea Electric Power Research Institute, Daejeon (Korea, Republic of); Park, Jai Hak [Chungbuk University, Cheongju (Korea, Republic of)

    2009-11-15

    Finite element (FE) analysis and experiment for weld residual stress (WRS) in the pressurizer safety nozzle mockup is described in various processes and results. Foremost of which is the dissimilar simulation metal welding (DMW) between carbon steel and austenitic stainless steel. Thermal and structural analyses were compared with actual residual stress, and actual measurements of. Magnitude and distribution of WRS in the nozzle mockup were assessed. Two measurement methods were used: hole-drilling method (HDM) with strain gauge for residual stress on the surface of the mockup, and block removal and splitting layer (BRSL) method for through-thickness. FE analysis and measurement data showed good agreement. In conclusion, the characteristics of weld residual stress of DMW could be well understood and the simplified FE analysis was verified as acceptable for estimating WRS

  17. Measurement and modeling of residual stress in a welded Haynes[reg] 25 cylinder

    International Nuclear Information System (INIS)

    Larsson, C.; Holden, T.M.; Bourke, M.A.M.; Stout, M.; Teague, J.; Lindgren, L.-E.

    2005-01-01

    An experimental and simulation study of residual stresses was made in the vicinity of a gas tungsten arc weld, used to join a hemispherical end cap to a cylinder. The capped cylinder is used in a satellite application and was fabricated from a Co-based Haynes[reg] 25 alloy. The cylinder was 34.7 mm in outer diameter and 3.3 mm in thickness. The experimental measurements were made by neutron diffraction and the simulation used the implicit Marc finite element code. The experimental resolution was limited to approximately 3 mm parallel to the axis of the cylinder (the weld was 6 mm in the same direction) and comparison over the same volume of the finite element prediction showed general agreement. Subject to the limited spatial resolution, the largest experimentally measured tensile residual stress was 180 MPa, located at the middle of the weld. However, the predictions suggest that there are regions in the weld where average tensile residual stresses as much as 400 MPa exist. One qualitative disparity between the model and the experiments was that the measurement included a larger degree of asymmetry on either side of the weld than predicted by the model

  18. Measurement and modeling of residual stress in a welded Haynes[reg] 25 cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, C. [Div. of Eng. Mat., Department of Mech. Eng., Linkoeping University, 58183 Linkoeping (Sweden)]. E-mail: clarsson@cfl.rr.com; Holden, T.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Bourke, M.A.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Stout, M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Teague, J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Lindgren, L.-E. [Div. Comp. Aided Design, Lulea University of Technology and Dalarna University, 97187 Lulea (Sweden)

    2005-06-15

    An experimental and simulation study of residual stresses was made in the vicinity of a gas tungsten arc weld, used to join a hemispherical end cap to a cylinder. The capped cylinder is used in a satellite application and was fabricated from a Co-based Haynes[reg] 25 alloy. The cylinder was 34.7 mm in outer diameter and 3.3 mm in thickness. The experimental measurements were made by neutron diffraction and the simulation used the implicit Marc finite element code. The experimental resolution was limited to approximately 3 mm parallel to the axis of the cylinder (the weld was 6 mm in the same direction) and comparison over the same volume of the finite element prediction showed general agreement. Subject to the limited spatial resolution, the largest experimentally measured tensile residual stress was 180 MPa, located at the middle of the weld. However, the predictions suggest that there are regions in the weld where average tensile residual stresses as much as 400 MPa exist. One qualitative disparity between the model and the experiments was that the measurement included a larger degree of asymmetry on either side of the weld than predicted by the model.

  19. Residual stress measurement on propellant tank of 2219 aluminum alloy and study on its weak spot

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chaoqun; Li, Huan; Li, Jianxiong; Luo, Chuanguang; Ni, Yanbing [Tianjin University, Tianjin (China)

    2017-05-15

    This paper presented residual stress measurement on two circumferential Variable polarity plasma arc welding (VPPAW) joints and one circular closed Friction stir welding (FSW) joint on the propellant tank of 2219 aluminum alloy using the indentation strain-gauge method. Quite large tensile residual stresses were attached to the center and inner areas of the circular closed FSW joint. There were very large tensile stresses in some points of the two circumferential VPPAW joints, among these points, the maximum value was +253 MPa, which was about 63 % of the yield strength of 410 MPa measured in the base material. In addition, the peak of compressive residual stress was about -160 MPa. Above all, there were two typical peaks of residual stress in the circumferential VPPAW joints, one was located in the middle part while the other one was near the start/end position of the joints. Combining the result of residual stress measurement with the characteristics of the tank structure, it can be concluded that circular closed FSW joint around the flange was a weak spot on the propellant tank. And the most vulnerable point on the circular closed FSW joint has also been found.

  20. Some problems of residual activity measurements

    International Nuclear Information System (INIS)

    Katrik, P.; Mustafin, E.; Strasik, I.; Pavlovic, M.

    2013-01-01

    As a preparatory work for constructing the Facility for Antiproton and Ion Research (FAIR) at GSI Darmstadt, samples of copper were irradiated by 500 MeV/u 238 U ion beam and investigated by gamma-ray spectroscopy. The nuclides that contribute dominantly to the residual activity have been identified and their contributions have been quantified by two different methods: from the whole-target gamma spectra and by integration of depth-profiles of residual activity of individual nuclides. Results obtained by these two methods are compared and discussed in this paper. (authors)

  1. Systematic Review of Uit Parameters on Residual Stresses of Sensitized AA5456 and Field Based Residual Stress Measurements for Predicting and Mitigating Stress Corrosion Cracking

    Science.gov (United States)

    2014-03-01

    University Press, 2009, pp. 820–824. [30] S. Kou, Welding Metallurgy , 2nd ed. Hoboken, NJ: John Wiley and Sons, Inc., 2003. [31] M. N.James et al...around welds in aluminum ship structures both in the laboratory and in the field. Tensile residual stresses are often generated during welding and, in...mitigate and even reverse these tensile residual stresses. This research uses x-ray diffraction to measure residual stresses around welds in AA5456 before

  2. Residual stress measurements by X-ray and neutron diffractions in heat-treated SiCw/A2014 composites

    International Nuclear Information System (INIS)

    Ohnuki, Takahisa; Fujita, Motoo; Tomota, Yo; Ono, Masayoshi

    1998-01-01

    Residual stresses due to various heat treatments in a 22 volume percent SiC whisker/A2014 metal matrix composite (MMC) were measured by using X-ray and neutron diffractions. Micro residual stresses generated from the differences in thermal expansion coefficients of the constituents and macro residual stresses associated with different cooling rates in the outer and inner regions of an MMC specimen must be distinguished in X-ray stress measurements. The conventional sin 2 ψ method under an assumption of plane stress condition has been found not to be applicable to the present MMC, because interactions among whiskers in the X-ray penetrating area yields σ 33 where the x 3 -axis is normal with respect to specimen's surface. An average value of σ 33 can be measured by X-ray diffraction technique, but does not seem enough to evaluate micro residual stresses. It is found that neutron diffraction is the most powerful method to measure micro residual stresses in the constituents. Elastic residual strains obtained by neutron diffraction in solution treated or T6 heat treated samples show good agreements with predictions calculated by using Eshelby inclusion theory coupled with the Mori-Tanaka mean field concept, indicating that the influence of stress relaxation is negligible. In addition, internal stresses relaxations during holding at room temperature, slow cooling from solution treatment temperature, or subzero cooling are discussed. (author)

  3. Measurement of residual stress in materials using neutrons. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2005-06-01

    One of the objectives of the IAEA's project on effective utilization of research reactors is to promote the use of the existing research reactors based on their capabilities and is implemented through workshops and technical meetings. Measurement of residual stress is one of the techniques that find wide applications in materials development and testing. The Technical Meeting on Measurement of Residual Stress Using Neutrons was organized to meet this objective. This publication is the outcome of the deliberations during the meeting and the presentations by the participants and is addressed to the research reactor managers, users and designers of facilities for reactor utilization. It will especially benefit those seeking to develop new facilities or upgrade the existing ones to enhance the utilization of their research reactors. Experts with a long experience in developing and using neutron beam instruments in high flux and medium flux research reactors participated in this technical meeting. They presented the design, development and utilization of the facilities at their respective centres and reviewed the current status of the residual stress measurements using neutron beams from research reactors. The sessions included brainstorming on the methodology and data analysis, characterization and standardization of the equipment and identifying the scope for further development. This publication refers to the determination of residual and/or applied stresses in polycrystalline materials using neutron diffraction technique. Stress is developed during the synthesis and use of materials such as alloys and compounds. Measurement of residual stress is essential to improve the quality of synthesized materials and diagnosis of failure and/or reliability of fabricated components. Neutron scattering has played an important role in studying structure and dynamics of condensed matter. Neutron scattering is a non-destructive technique and is useful for testing large samples. The

  4. Remarks on residual stress measurement by hole-drilling and electronic speckle pattern interferometry.

    Science.gov (United States)

    Barile, Claudia; Casavola, Caterina; Pappalettera, Giovanni; Pappalettere, Carmine

    2014-01-01

    Hole drilling is the most widespread method for measuring residual stress. It is based on the principle that drilling a hole in the material causes a local stress relaxation; the initial residual stress can be calculated by measuring strain in correspondence with each drill depth. Recently optical techniques were introduced to measure strain; in this case, the accuracy of the final results depends, among other factors, on the proper choice of the area of analysis. Deformations are in fact analyzed within an annulus determined by two parameters: the internal and the external radius. In this paper, the influence of the choice of the area of analysis was analysed. A known stress field was introduced on a Ti grade 5 sample and then the stress was measured in correspondence with different values of the internal and the external radius of analysis; results were finally compared with the expected theoretical value.

  5. Residual volume measurements in CAPD patients with exogenous and endogenous solutes

    NARCIS (Netherlands)

    Imholz, A. L.; Koomen, G. C.; Struijk, D. G.; Arisz, L.; Krediet, R. T.

    1992-01-01

    Accurate residual volume (RV) measurements are needed in studies on fluid kinetics during CAPD. In this study 10 stable CAPD patients were examined twice within 1 week. On both occasions RV after drainage was calculated by the indicator dilution method. Exogenous (dextran 70, inulin) and endogenous

  6. Serum organochlorine pesticide residues and risk of testicular germ cell carcinoma: a population-based case-control study.

    Science.gov (United States)

    Biggs, Mary L; Davis, Mark D; Eaton, David L; Weiss, Noel S; Barr, Dana B; Doody, David R; Fish, Sherianne; Needham, Larry L; Chen, Chu; Schwartz, Stephen M

    2008-08-01

    Testicular germ cell carcinoma (TGCC) is the most common malignancy among men ages 20 to 34 years. Although the pathogenesis of TGCC is poorly understood, suboptimal androgen levels or impaired androgen signaling may play a role. Some persistent organochlorine pesticides commonly found in human tissue possess antiandrogenic properties. We examined whether the risk of TGCC is associated with serum levels of 11 organochlorine pesticides, including p,p'-DDE, and whether the p,p'-DDE-TGCC association is modified by CAG or GGN repeat polymorphisms in the androgen receptor gene. We conducted a population-based case-control study among 18- to 44-year-old male residents of three Washington State counties. Cases (n = 246) were diagnosed during 1999 to 2003 with a first, primary TGCC. Controls (n = 630) were men of similar age with no history of TGCC from the same population identified through random-digit telephone dialing. Questionnaires elicited information on demographic, medical, and lifestyle factors. A blood specimen provided serum for gas chromatography-high-resolution mass spectrometry analysis of organochlorine pesticide residues and DNA for genotyping. We observed no clear patterns between TGCC risk and concentrations of any of the organochlorines measured, nor did we observe that the risk associated with p,p'-DDE was modified by androgen receptor CAG ( or =23 repeats) or GGN ( or =17 repeats) genotype. This study does not provide support for the hypothesis that adult exposure to organochlorine pesticides is associated with risk of TGCC. Due to uncertainty regarding how well organochlorine levels measured in adulthood reflect exposures during early life, further research is needed using exposure measurements collected in utero or during infancy.

  7. Strategy utilized for assessing baseline risks to human health from K-65 and metal oxide residues stored at the Fernald Site

    International Nuclear Information System (INIS)

    Harmon, J.E.; Janke, R.C.

    1995-01-01

    The U.S. Department of Energy (DOE) is responsible for cleanup activities at the Fernald Environmental Management Project (FEMP) site in southwestern Ohio. The 425-hectare site consists of a former 55-hectare Production Area, an adjacent Waste Storage Area and various support facilities. From 1952 until 1989, the FEMP processed uranium into metallic open-quotes feedclose quotes materials for other DOE facilities in the nation's defense program. In accordance with the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA), the FEMP site is currently listed on the National Priorities List (NPL). To facilitate an expeditious cleanup effort, environmental issues associated with site cleanup are being managed under five operable units. This paper summarizes the risk assessment strategy employed to determine baseline human health risks associated with K-65 and metal oxide residues currently stored in Operable Unit 4. The K-65 and metal oxide residues were generated during the 1950s as a result of the extraction of uranium from uranium-bearing ores and concentrates. These residues are currently stored within Operable Unit 4 in concrete silos. Silos I and 2 contain approximately 6,120 cubic meters [m 3 ] (8,005 cubic yards [yd 3 ]) of K-65 residues, while silos 3 contains approximately 3890 m 3 (5,080 yd 3 ) of cold metal oxides. These concrete silos are beyond their design life and require remedial action. The risk assessment conducted for Operable Unit 4 constitutes the first detailed human health risk assessment to be approved by the Environmental Protection Agency (EPA) for the CERCLA clean-up effort at the FEMP Site. This paper discusses the FEMP's use of a Risk Information Quality Objective process in concert with the traditional risk assessment approach to determine baseline risk to human health and the environment posed by Operable Unit 4. A summary of the baseline risks to human health is also presented

  8. Measurement of residual radioactivity in cooper exposed to high energy heavy ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eunjoo; Nakamura, Takashi [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Uwamino, Yoshitomo; Ito, Sachiko; Fukumura, Akifumi

    1999-03-01

    The residual radioactivities produced by high energy heavy ions have been measured using the heavy ion beams of the Heavy Ion Medical Accelerator (HIMAC) at National Institute of Radiological Sciences. The spatial distribution of residual radioactivities in 3.5 cm, 5.5 cm and 10 cm thick copper targets of 10 cm x 10 cm size bombarded by 290 MeV/u, 400 MeV/u-{sup 12}C ion beams and 400 MeV/u-{sup 20}Ne ion beam, respectively, were obtained by measuring the gamma-ray activities of 0.5 mm thick copper foil inserted in the target with a high purity Ge detector after about 1 hour to 6 hours irradiation. (author)

  9. Measurement of the residual stresses in a PWR Control Rod Drive Mechanism nozzle

    OpenAIRE

    Coules, Harry; Smith, David

    2018-01-01

    Residual stress in the welds that attach Control Rod Drive Mechanism nozzles into the upper head of a PWR reactor vessel can influence the vessel's structural integrity and initiate Primary Water Stress Corrosion Cracking. PWSCC at Alloy 600 CRDM nozzles has caused primary coolant leakage in operating PWRs. We have used Deep Hole Drilling to characterise residual stresses in a PWR vessel head. Measurements of the internal cladding and nozzle attachment weld showed that although modest tensile...

  10. Drug residues and endocrine disruptors in drinking water: risk for humans?

    Science.gov (United States)

    Touraud, Evelyne; Roig, Benoit; Sumpter, John P; Coetsier, Clémence

    2011-11-01

    The presence of pharmaceuticals and endocrine disruptors in the environment raises many questions about risk to the environment and human health. Environmental exposure has been largely studied, providing to date a realistic picture of the degree of contamination of the environment by pharmaceuticals and hormones. Conversely, little information is available regarding human exposure. NSAIDS, carbamazepine, iodinated contrast media, β-blockers, antibiotics have been detected in drinking water, mostly in the range of ng/L. it is questioned if such concentrations may affect human health. Currently, no consensus among the scientific community exists on what risk, if any, pharmaceuticals and endocrine disruptors pose to human health. Future European research will focus, on one hand, on genotoxic and cytotoxic anti-cancer drugs and, on the other hand, on the induction of genetic resistance by antibiotics. This review does not aim to give a comprehensive overview of human health risk of drug residues and endocrine disruptors in drinking water but rather highlight important topics of discussion. Copyright © 2011. Published by Elsevier GmbH.

  11. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  12. Uses of risk importance measures

    International Nuclear Information System (INIS)

    Mankamo, T.; Poern, K.; Holmberg, J.

    1991-05-01

    Risk importance measures provide an understandable and practical way of presenting probabilistic safety analysis results which too often tend to remain abstract numbers without real insight into the content. The report clarifies the definitions, relationships and interpretations of the three most basic measures: Risk increase factor, risk decrease factor, and fractional contribution. The above three measures already cover the main types of risk importance measures. Many other importance measures presented in literature are close variants to some of these three measures. They are related in many cases so that, for a technical system considered, the two other measures can be derived from the one calculated first. However, the practical interpretations are different, and hence each three measures have their own uses and rights to existence. The fundamental aspect of importance measures is, that they express some specific influence of a basic event on the total risk. The basic failure or error events are the elements from which the reliability and risk models are constituted. The importance measures are relative, which is an advantage compared to absolute risk numbers, due to insensitivity with respect to quantification uncertainties. Therefore they are particularly adapted to give first hand guidance where to focus main interest from the system's risk and reliability point of view and wherefrom to continue the analysis with more sophisticated methods requiring more effort

  13. Residual Stresses in DC cast Aluminum Billet: Neutron Diffraction Measurements and Thermomechanical Modeling

    International Nuclear Information System (INIS)

    Drezet, J.-M.; Evans, A.; Pirling, T.

    2011-01-01

    Thermally-induced residual stresses, generated during the industrial Direct Chill casting process of aluminum alloys, can cause both significant safety concerns as well as the formation of defects during down-stream processing. Although these thermally induced strains can be partially relieved by permanent deformation, cracks will be generated either during solidification (hot tears) or post-solidification cooling (cold cracks) when stresses exceed the deformation limit of the alloy. Furthermore, the thermally induced strains result in the presence of large internal stresses within the billet before further processing steps. Although numerical models have been previously developed to compute these residual stresses, most of the computations have been validated only against measured surface distortions. In the present work, the variation in residual elastic strains and stresses in the steady state regime of casting has been measured as a function of radial position using neutron diffraction in an AA6063 grain-refined cylindrical billet. These measurements have been carried out on the same billet section at Poldi at PSI-Villigen and at Salsa at ILL-Grenoble and compare favorably. The results are used to validate a thermo-mechanical finite element casting model and to assess the level of stored elastic energy within the billet.

  14. Remarks on Residual Stress Measurement by Hole-Drilling and Electronic Speckle Pattern Interferometry

    Directory of Open Access Journals (Sweden)

    Claudia Barile

    2014-01-01

    Full Text Available Hole drilling is the most widespread method for measuring residual stress. It is based on the principle that drilling a hole in the material causes a local stress relaxation; the initial residual stress can be calculated by measuring strain in correspondence with each drill depth. Recently optical techniques were introduced to measure strain; in this case, the accuracy of the final results depends, among other factors, on the proper choice of the area of analysis. Deformations are in fact analyzed within an annulus determined by two parameters: the internal and the external radius. In this paper, the influence of the choice of the area of analysis was analysed. A known stress field was introduced on a Ti grade 5 sample and then the stress was measured in correspondence with different values of the internal and the external radius of analysis; results were finally compared with the expected theoretical value.

  15. Leaching characteristics of calcium-based compounds in MSWI Residues: From the viewpoint of clogging risk

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yi [State Key Laboratory of Pollution Control & Resource Reuse, Tongji University, Shanghai 200092 (China); Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092 (China); Zhang, Hua, E-mail: zhanghua_tj@tongji.edu.cn [State Key Laboratory of Pollution Control & Resource Reuse, Tongji University, Shanghai 200092 (China); Phoungthong, Khamphe [State Key Laboratory of Pollution Control & Resource Reuse, Tongji University, Shanghai 200092 (China); Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092 (China); Shi, Dong-Xiao; Shen, Wen-Hui [Changzhou Domestic Waste Treatment Center, Changzhou 213000 (China); Shao, Li-Ming [Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092 (China); Center for the Technology Research and Training on Household Waste in Small Towns & Rural Area, Ministry of Housing and Urban–Rural Development of PR China (MOHURD), Shanghai 200092 (China); He, Pin-Jing, E-mail: solidwaste@tongji.edu.cn [Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092 (China); Center for the Technology Research and Training on Household Waste in Small Towns & Rural Area, Ministry of Housing and Urban–Rural Development of PR China (MOHURD), Shanghai 200092 (China)

    2015-08-15

    Highlights: • The leaching behavior of Ca-based compounds commonly in MSWI residues was studied. • pH is the crucial factor for calcium leaching process. • CaCO{sub 3} was the most sensitive to leaching temperature and Ca{sub 3}(PO{sub 4}){sub 2} was the least. • Ca leaching of MSWIBA and SAPCR attributed to CaCO{sub 3} and Ca{sub 3}(PO{sub 4}){sub 2} respectively. • Potential clogging ability of MSWI residues leachate in open air was calculated. - Abstract: Leachate collection system (LCS) clogging caused by calcium precipitation would be disadvantageous to landfill stability and operation. Meanwhile, calcium-based compounds are the main constituents in both municipal solid waste incineration bottom ash (MSWIBA) and stabilized air pollution control residues (SAPCR), which would increase the risk of LCS clogging once these calcium-rich residues were disposed in landfills. The leaching behaviors of calcium from the four compounds and municipal solid waste incineration (MSWI) residues were studied, and the influencing factors on leaching were discussed. The results showed that pH was the crucial factor in the calcium leaching process. CaCO{sub 3} and CaSiO{sub 3} began leaching when the leachate pH decreased to less than 7 and 10, respectively, while Ca{sub 3}(PO{sub 4}){sub 2} leached at pH < 12. CaSO{sub 4} could hardly dissolve in the experimental conditions. Moreover, the sequence of the leaching rate for the different calcium-based compounds is as follows: CaSiO{sub 3} > Ca{sub 3}(PO{sub 4}){sub 2} > CaCO{sub 3}. The calcium leaching from the MSWIBA and SAPCR separately started from pH < 7 and pH < 12, resulting from CaCO{sub 3} and Ca{sub 3}(PO{sub 4}){sub 2} leaching respectively, which was proven by the X-ray diffraction results. Based on the leaching characteristics of the different calcium compounds and the mineral phase of calcium in the incineration residues, simulated computation of their clogging potential was conducted, providing the

  16. Human immunodeficiency virus prevalence, incidence, and residual transmission risk in first-time and repeat blood donations in Zimbabwe: implications on blood safety.

    Science.gov (United States)

    Mapako, Tonderai; Mvere, David A; Chitiyo, McLeod E; Rusakaniko, Simbarashe; Postma, Maarten J; van Hulst, Marinus

    2013-10-01

    National Blood Service Zimbabwe human immunodeficiency virus (HIV) risk management strategy includes screening and discarding of first-time donations, which are collected in blood packs without an anticoagulant (dry pack). To evaluate the impact of discarding first-time donations on blood safety the HIV prevalence, incidence, and residual risk in first-time and repeat donations (wet packs) were compared. Donor data from 2002 to 2010 were retrieved from a centralized national electronic donor database and retrospectively analyzed. Chi-square test was used to compare HIV prevalence with relative risk (RR), and the RR point estimates and 95% confidence interval (CI) are reported. Trend analysis was done using Cochran-Armitage trend test. HIV residual risk estimates were determined using published residual risk estimation models. Over the 9 years the overall HIV prevalence estimates are 1.29% (n = 116,058) and 0.42% (n = 434,695) for first-time and repeat donations, respectively. The overall RR was 3.1 (95% CI, 2.9-3.3; p donations in first-time was 1:7384 (range, 1:11,308-1:5356) and in repeat donors it was 1:5496 (range, 1:9943-1:3347). The significantly high HIV prevalence estimates recorded in first-time over repeat donations is indicative of the effectiveness of the HIV risk management strategy. However, comparable residual transmission risk estimates in first-time and repeat donors point to the need to further review the risk management strategies. Given the potential wastage of valuable resources, future studies should focus on the cost-effectiveness and utility of screening and discarding first-time donations. © 2013 American Association of Blood Banks.

  17. Characterization of roadway stormwater system residuals for reuse and disposal options

    International Nuclear Information System (INIS)

    Jang, Yong-Chul; Jain, Pradeep; Tolaymat, Thabet; Dubey, Brajesh; Singh, Shrawan; Townsend, Timothy

    2010-01-01

    The chemical characterization of sediments accumulated in catch basins and stormwater ponds provides important information for assessing risks associated with management of these residuals upon removal of accumulated deposits in stormwater systems. In this study, over a period of 15 months, more than 150 residual samples were collected from 77 catch basin units and 22 stormwater ponds from 16 municipalities throughout the state of Florida. Concentrations (mg/kg) of metals and metalloids (arsenic, barium, cadmium, chromium, copper, lead, mercury, nickel, selenium, silver, and zinc) and trace organics (volatile organics, semi-volatile organics, herbicides, and pesticides) in the sediments were measured. In addition, the synthetic precipitation leaching procedure (SPLP) was utilized to evaluate pollutant leachability risk for a subset of the samples collected. Measured pollutant concentrations were compared to corresponding risk-based guidelines in Florida (i.e., Florida soil cleanup target levels) to assess potential human health risks of beneficial use of these residuals through land application. Leached concentrations were compared to risk-based water quality guidelines (i.e., Florida groundwater cleanup target levels) to examine the potential for groundwater contamination. Although several metals (arsenic, barium, chromium, copper, nickel, lead, and zinc) were routinely detected in the catch basin and stormwater pond sediments, their concentrations were generally lower than the Florida's risk-based cleanup target levels for soils. A small number of organochlorine compounds (e.g., 4,4'-DDE, 4,4'-DDT) were detected, but only in a limited number of the samples (less than 10%); leaching of trace organic pollutants above the Florida risk-based groundwater thresholds was rare. The results suggest that when land-applied or beneficially used, these residuals are not expected to pose a significant threat to human health or the environment and the results of this research

  18. Residual tumor size and IGCCCG risk classification predict additional vascular procedures in patients with germ cell tumors and residual tumor resection: a multicenter analysis of the German Testicular Cancer Study Group.

    Science.gov (United States)

    Winter, Christian; Pfister, David; Busch, Jonas; Bingöl, Cigdem; Ranft, Ulrich; Schrader, Mark; Dieckmann, Klaus-Peter; Heidenreich, Axel; Albers, Peter

    2012-02-01

    Residual tumor resection (RTR) after chemotherapy in patients with advanced germ cell tumors (GCT) is an important part of the multimodal treatment. To provide a complete resection of residual tumor, additional surgical procedures are sometimes necessary. In particular, additional vascular interventions are high-risk procedures that require multidisciplinary planning and adequate resources to optimize outcome. The aim was to identify parameters that predict additional vascular procedures during RTR in GCT patients. A retrospective analysis was performed in 402 GCT patients who underwent 414 RTRs in 9 German Testicular Cancer Study Group (GTCSG) centers. Overall, 339 of 414 RTRs were evaluable with complete perioperative data sets. The RTR database was queried for additional vascular procedures (inferior vena cava [IVC] interventions, aortic prosthesis) and correlated to International Germ Cell Cancer Collaborative Group (IGCCCG) classification and residual tumor volume. In 40 RTRs, major vascular procedures (23 IVC resections with or without prosthesis, 11 partial IVC resections, and 6 aortic prostheses) were performed. In univariate analysis, the necessity of IVC intervention was significantly correlated with IGCCCG (14.1% intermediate/poor vs 4.8% good; p=0.0047) and residual tumor size (3.7% size risk features must initially be identified as high-risk patients for vascular procedures and therefore should be referred to specialized surgical centers with the ad hoc possibility of vascular interventions. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. Testing for Distortions in Performance Measures: An Application to Residual Income Based Measures like Economic Value Added

    NARCIS (Netherlands)

    Sloof, R.; van Praag, M.

    2015-01-01

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based performance

  20. Effect of processing on the disappearance of pesticide residues in fresh-cut lettuce: Bioavailability and dietary risk.

    Science.gov (United States)

    Camara, Miguel A; Barba, Alberto; Cermeño, Sandra; Martinez, Gracia; Oliva, Jose

    2017-12-02

    The aim of this research is to establish the processing factors of six pesticides durong the preparation of fresh-cut lettuce and to assess the risk of ingestion of pesticide residues associated with the consumption of the same. A field study was carried out on the dissipation of three insecticides (imidacloprid, tebufenozide, cypermethrin) and three fungicides (metalaxyl, tebuconazole, azoxystrobin) during treatment conditions simulating those used for commercial fresh-cut lettuce. A simultaneous residue analysis method is validated using QuEChERS extraction with acetonitrile and CG-MS and LC-MS/MS analysis. The residues detected after field application never exceed the established Maximum Residue Limits. The processing factors were generally less than 1 (between 0.34 for tebufenozide and 0.53 for imidacloprid), indicating that the process, as a whole, considerably reduces residue levels in processed lettuce compared to fresh lettuce. It is confirmed that cutting, followed by washing and drying, considerably reduces the residues. A matrix effect in the dialyzation of the pesticides is observed and the in vitro study of bioavailability establishes a low percentage of stomach absorption capacity (lettuce showed no concerns for consumer health.

  1. Comparison of Measured Residual Stress in an Extra Thick Multi-pass Weld Using Neutron Diffraction Method and Inherent Strain Method

    International Nuclear Information System (INIS)

    Park, JeongUng; An, GyuBaek; Woo, Wan Chuck

    2015-01-01

    With the increase of large-scale containership, a large amount of high-strength steels with extra thick plates is being extensively used. The welding stress existing in the extra thick welded plates has a significant effect on the integrity of the component in terms of brittle fracture and fatigue behavior. It has been reported that welding residual stress distribution in an extra thick plate can affect the propagation path of the crack. Therefore, it is important to measure the distribution of welding residual stresses for the reliable design of the welded structures. So far various researches have been carried out for the determination of residual stresses on the surface of steels. In this paper, the total residual stresses in the 70 mm thick multipass FACW butt joint were measured by integrating initial stress into ISM. Concretely, two methods named as initial stress integrated ISM and initial inherent strain integrated ISM were employed to determine the total residual stresses. Furthermore, the distributions of residual stresses were compared with the results of the Neutron Diffraction Method(NDM). In order to measure the three dimensional residual stresses in the welded joint with initial stresses existing before welding, initial stress integrated ISM and initial inherent strain integrated ISM were developed. The residual stresses in 70 mm-thick butt joint by flux cored arc welding were carried out with a good accuracy using the two developed methods. The residual stresses in welded joint using both initial stress integrated ISM and initial inherent strain integrated ISM agreed well with the results measured by Neutron Diffraction Method. This suggests that the integrated ISM is a reliable method for residual stress measurement if initial stress existed

  2. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  3. Minimal Residual Disease in Acute Myeloid Leukemia

    Science.gov (United States)

    Hourigan, Christopher S.; Karp, Judith E.

    2014-01-01

    Technological advances in the laboratory have lead to substantial improvements in clinical decision-making by the use of pre-treatment prognostic risk stratification factors in acute myeloid leukemia (AML). Unfortunately similar progress has not been made in treatment response criteria, with the definition of “complete remission” in AML largely unchanged for over half a century. Several recent clinical trials have demonstrated that higher sensitivity measurements of residual disease burden during or after treatment can be performed, that results are predictive for clinical outcome and can be used to improve outcomes by guiding additional therapeutic intervention to patients in clinical complete remission but at increased relapse risk. We review here these recent trials, the characteristics and challenges of the modalities currently used to detect minimal residual disease (MRD), and outline opportunities to both refine detection and better clinically utilize MRD measurements. MRD measurement is already the standard of care in other myeloid malignancies such as chronic myelogenous leukemia (CML) and acute promyelocytic leukemia (APL). It is our belief that response criteria for non-APL AML should be updated to include assessment for molecular complete remission (mCR) and that recommendations for post-consolidation surveillance should include regular monitoring for molecular relapse as a standard of care. PMID:23799371

  4. Measurement of residual stresses by the moire method

    Science.gov (United States)

    Sciammarella, C. A.; Albertazzi, A., Jr.

    Three different applications of the moire method to the determination of residual stresses and strains are presented. The three applications take advantage of the property of ratings to record the changes of the surface they are printed on. One of the applications deals with thermal residual stresses, another with contact residual stress and the third one is a generalization of the blind hole technique. This last application is based on a computer assisted moire technique and on the generalization of the quasi-heterodyne techniques of fringe pattern analysis.

  5. Tailoring diffraction technique Rietveld method on residual stress measurements of cold-can oiled 304 stainless steel plates

    International Nuclear Information System (INIS)

    Parikin; Killen, P.; Anis, M.

    2003-01-01

    Tailoring of diffraction technique-Rietveld method on residual stress measurements of cold-canailed stainless steel 304 plates assuming the material is isotopic, the residual stress measurements using X-ray powder diffraction is just performed for a plane lying in a large angle. For anisotropic materials, the real measurements will not be represented by the methods. By Utilizing of all diffraction peaks in the observation region, tailoring diffraction technique-Rietveld analysis is able to cover the limitations. The residual stress measurement using X-ray powder diffraction tailored by Rietveld method, in a series of cold-canailed stainless steel 304 plates deforming; 0, 34, 84, 152, 158, 175, and 196 % reduction in thickness, have been reported. The diffraction data were analyzed by using Rietveld structure refinement method. Also, for all cold-canailed stainless steel 304 plates cuplikans, the diffraction peaks are broader than the uncanailed one, indicating that the strains in these cuplikans are inhomogeneous. From an analysis of the refined peak shape parameters, the average root-mean square strain, which describes the distribution of the inhomogeneous strain field, was calculated. Finally, the average residual stresses in cold-canailed stainless steel 304 plates were shown to be a combination effect of hydrostatic stresses of martensite particles and austenite matrix. The average residual stresses were evaluated from the experimentally determined average lattice strains in each phase. It was found the tensile residual stress in a cuplikan was maximum, reaching 442 MPa, for a cuplikan reducing 34% in thickness and minimum for a 196% cuplikan

  6. A quantitative assessment of risks of heavy metal residues in laundered shop towels and their use by workers.

    Science.gov (United States)

    Connor, Kevin; Magee, Brian

    2014-10-01

    This paper presents a risk assessment of exposure to metal residues in laundered shop towels by workers. The concentrations of 27 metals measured in a synthetic sweat leachate were used to estimate the releasable quantity of metals which could be transferred to workers' skin. Worker exposure was evaluated quantitatively with an exposure model that focused on towel-to-hand transfer and subsequent hand-to-food or -mouth transfers. The exposure model was based on conservative, but reasonable assumptions regarding towel use and default exposure factor values from the published literature or regulatory guidance. Transfer coefficients were derived from studies representative of the exposures to towel users. Contact frequencies were based on assumed high-end use of shop towels, but constrained by a theoretical maximum dermal loading. The risk estimates for workers developed for all metals were below applicable regulatory risk benchmarks. The risk assessment for lead utilized the Adult Lead Model and concluded that predicted lead intakes do not constitute a significant health hazard based on potential worker exposures. Uncertainties are discussed in relation to the overall confidence in the exposure estimates developed for each exposure pathway and the likelihood that the exposure model is under- or overestimating worker exposures and risk. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Models of Credit Risk Measurement

    OpenAIRE

    Hagiu Alina

    2011-01-01

    Credit risk is defined as that risk of financial loss caused by failure by the counterparty. According to statistics, for financial institutions, credit risk is much important than market risk, reduced diversification of the credit risk is the main cause of bank failures. Just recently, the banking industry began to measure credit risk in the context of a portfolio along with the development of risk management started with models value at risk (VAR). Once measured, credit risk can be diversif...

  8. A liquid crystalline medium for measuring residual dipolar couplings over a wide range of temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hong; Eberstadt, Matthias; Olejniczak, Edward T.; Meadows, Robert P.; Fesik, Stephen W. [Abbott Laboratories (United States)

    1998-10-15

    A mixture of dilauroyl phosphatidylcholine (DLPC) and 3-(cholamidopropyl)dimethylammonio-2-hydroxyl-1-propane sulfonate (CHAPSO) in water forms disc shaped bicelles that become ordered at high magnetic fields over a wide range of temperatures. As illustrated for the FK506 binding protein (FKBP), large residual dipolar couplings can be measured for proteins dissolved in low concentrations (5% w/v) of a DLPC/CHAPSO medium at a molar ratio of 4.2:1. This system is especially useful for measuring residual dipolar couplings for molecules that are only stable at low temperatures.

  9. Residual Stress Measurement of Coarse Crystal Grain in Aluminium Casting Alloy by Neutron Diffraction

    International Nuclear Information System (INIS)

    Nishida, Masayuki; Watanabe, Yoshitaka; Hanabusa, Takao

    2009-01-01

    Full text: Neutron stress measurement can detect strain and stress information in deep region because of large penetration ability of neutron beams. The present paper describes procedure and results in the residual stress measurement of aluminium casting alloy by neutron diffraction. Usually, the aluminium casting alloy includes the large crystal grains. The existence of large crystal grains makes it difficult to estimate the residual stresses in highly accuracy. In this study, the modified three axial method using Hook's equation was employed for neutron stress measurement. These stress measurements were performed under the two kinds of new techniques. One is a rocking curve method to calculate the principal strains in three directions. The peak profiles which appear discretely on rocking curves were translated to principle stresses by the Bragg law and the basic elastic theory. Another is the consideration of measurement positions and the edge effect in the neutron irradiated area (volume gage). The edge effect generates the errors of 2θ-peak position in the neutron stress measurement. In this study, the edge effect was investigated in detail by a small bit of copper single crystal. The copper bit was moved and scanned on three dimensionally within the gage volume. Furthermore, the average strains of symmetrical positions are measure by the sample turning at 180 degrees, because the error distributions of the 2θ-peak position followed to positions inside the gage volume. Form these results of this study, the residual stresses in aluminium casting alloy which includes the large crystal grains were possible to estimate by neutron stress measurement with the rocking curve method and the correction of the edge effect. (author)

  10. Determination of potassium concentration in salt water for residual beta radioactivity measurements

    International Nuclear Information System (INIS)

    Suarez-Navarro, J.A.; Pujol, Ll.

    2004-01-01

    High interferences may arise in the determination of potassium concentration in salt water. Several analytical methods were studied to determine which method provided the most accurate measurements of potassium concentration. This study is relevant for radiation protection because the exact amount of potassium in water samples must be known for determinations of residual beta activity concentration. The fitting algorithm of the calibration curve and estimation of uncertainty in potassium determinations were also studied. The reproducibility of the proposed analytical method was tested by internal and external validation. Furthermore, the residual beta activity concentration of several Spanish seawater and brackish river water samples was determined using the proposed method

  11. Residual phase noise measurements of the input section in a receiver

    International Nuclear Information System (INIS)

    Mavric, Uros; Chase, Brian; Fermilab

    2007-01-01

    If not designed properly, the input section of an analog down-converter can introduce phase noise that can prevail over other noise sources in the system. In the paper we present residual phase noise measurements of a simplified input section of a classical receiver that is composed of various commercially available mixers and driven by an LO amplifier

  12. Synchrotron measurements of local microstructure and residual strains in ductile cast iron

    DEFF Research Database (Denmark)

    Zhang, Yubin; Andriollo, Tito; Fæster, Søren

    2017-01-01

    The local microstructure and distribution of thermally induced residual strains in ferrite matrix grains around an individual spherical graphite nodule in ductile cast iron (DCI) were measured using a synchrotron X-ray micro-diffraction technique. It is found that the matrix grains are deformed...

  13. Residual strain dependence on the matrix structure in RHQ-Nb3Al wires by neutron diffraction measurement

    International Nuclear Information System (INIS)

    Jin Xinzhe; Nakamoto, Tatsushi; Tsuchiya, Kiyosumi; Ogitsu, Toru; Yamamoto, Akira; Ito, Takayoshi; Harjo, Stefanus; Kikuchi, Akihiro; Takeuchi, Takao; Hemmi, Tsutomu

    2012-01-01

    We prepared three types of non-Cu RHQ-Nb 3 Al wire sample with different matrix structures: an all-Ta matrix, a composite matrix of Nb and Ta with a Ta inter-filament, and an all-Nb matrix. Neutron diffraction patterns of the wire samples were measured at room temperature in the J-PARC ‘TAKUMI’. To obtain the residual strains of the materials, we estimated the lattice constant a by multi-peak analysis in the wires. A powder sample of each wire was measured, where the powder was considered to be strain free. The grain size of all the powder samples was below 0.02 mm. For the wire sample with the all-Nb matrix, we also obtained the lattice spacing d by a single-peak analysis. The residual strains of the Nb 3 Al filament were estimated from the two analysis results and were compared. The resulting residual strains obtained from the multi-peak analysis showed a good accuracy with small standard deviation. The multi-peak analysis results for the residual strains of the Nb 3 Al filaments in the three samples (without Cu plating) were all tensile residual strain in the axial direction, of 0.12%, 0.12%, and 0.05% for the all-Ta matrix, the composite matrix, and the all-Nb matrix, respectively. The difference in the residual strain of the Nb 3 Al filament between the composite and all-Nb matrix samples indicates that the type of inter-filament material shows a great effect on the residual strain. In this paper, we report the method of measurement, method of analysis, and results for the residual strain in the three types of non-Cu RHQ-Nb 3 Al wires. (paper)

  14. Residual Stress Measurement of SiC tile/Al7075 Hybrid Composites by Neutron Diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Bok; Lee, Jun Ho; Hong, Soon Hyung; Ryu, Ho Jin [KAIST, Daejeon (Korea, Republic of); Lee, Sang Bok; Lee, Sang Kwan [Korea Institute of Materials Science, Changwon (Korea, Republic of); Muslihd, M. Rifai [Center for Advanced Materials Science and Technology, Tangerang (India)

    2016-05-15

    In this research, SiC which has low density, high compressive strength, and high elastic modulus was used to fabricate the armor plate. In addition, Al which has low density and high toughness was used for a metal matrix of the composites. If two materials are combined, the composite can be effective materials for light weight armor applications. However, the existence of a large difference in coefficients of thermal expansion (CTE) between SiC and Al matrix, SiC/Al composites can have residual stresses while cooled in the fabrication process. Previous research reported that residual stresses in the composites or microstructures have an effect on the fatigue life and their mechanical properties. Some researchers reported about the residual stresses in the SiCp/Al metal matrix composites by numerical simulation systems, X-ray diffraction, and destructive methods. In order to analyze the residual stress of SiC/Al composites, the neutron diffraction as the non-destructive method was performed in this research. The 50 vol.% SiC{sub p}/Al7075 composites and SiC tile inserted 50 vol.% SiC{sub p}/Al7075 hybrid composites were measured to analyze the residual stress of Al (111) and SiC (111). Both samples had the tensile residual stresses in the Al (111) and the compressive residual stresses in the SiC (111) due to the difference in CTE.

  15. Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Osifo, Otasowie

    2007-03-01

    In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained for the determination of residual heat are presented, showing an agreement of (2-3) % with both calorimetric and calculated data. In addition, the ability to verify declared data such as discharge burnup and cooling time is demonstrated

  16. Residual stress measurements in a ferritic steel/In625 superalloy dissimilar metal weldment using neutron diffraction and deep-hole drilling

    International Nuclear Information System (INIS)

    Skouras, A.; Paradowska, A.; Peel, M.J.; Flewitt, P.E.J.; Pavier, M.J.

    2013-01-01

    This paper reports the use of non-invasive and semi-invasive techniques to measure the residual stresses in a large dissimilar weldment. This took the form of a butt weld between two sections of a P92 steel pipe, joined using an In625 welding consumable. Residual stress measurements have been carried out on the 30 mm thick welded pipe using the deep-hole drilling technique to characterise the through wall section residual stress distribution for the weld metal, HAZ and parent material. In addition, neutron diffraction measurements have been carried out within the weld zone. Diffraction patterns presented a high intensity and sharp peaks for the base P92 steel material. However measurements in the weld superalloy material were proven problematic as very weak diffraction patterns were observed. A thorough examination of the weld material suggested that the likely cause of this phenomenon was texture in the weld material created during the solidification phase of the welding procedure. This paper discusses the challenges in the execution and interpretation of the neutron diffraction results and demonstrates that realistic measurements of residual stresses can be achieved, in complex dissimilar metal weldments. Highlights: ► One of the few papers to measure residual stresses on dissimilar metal welds. ► Paper managed to provide realistic measurements of residual stresses using the DHD and ND technique. ► Results of this study have demonstrated the effect of texture during the ND measurements.

  17. Type I and type II residual stress in iron meteorites determined by neutron diffraction measurements

    Science.gov (United States)

    Caporali, Stefano; Pratesi, Giovanni; Kabra, Saurabh; Grazzi, Francesco

    2018-04-01

    In this work we present a preliminary investigation by means of neutron diffraction experiment to determine the residual stress state in three different iron meteorites (Chinga, Sikhote Alin and Nantan). Because of the very peculiar microstructural characteristic of this class of samples, all the systematic effects related to the measuring procedure - such as crystallite size and composition - were taken into account and a clear differentiation in the statistical distribution of residual stress in coarse and fine grained meteorites were highlighted. Moreover, the residual stress state was statistically analysed in three orthogonal directions finding evidence of the existence of both type I and type II residual stress components. Finally, the application of von Mises approach allowed to determine the distribution of type II stress.

  18. Residue Levels and Risk Assessment of Pesticides in Pistachio Nuts in Iran

    Directory of Open Access Journals (Sweden)

    Azadeh Emami

    2017-02-01

    Full Text Available Background: Pistachio is one of the main nutrients, not only as a strategic crop but also as a main type of nut, in Iranians’ food cycle. The aim of this study was to measure the relative safety of Iranian pistachio based on the standard pesticide’s residue limits, which should be monitored and assessed in the cultivation of pistachio in order to confirm its public health. Methods: Fifty samples of pistachios of different brands were collected from Tehran markets in 2015. QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe sampling method was used in order to determine the pesticide’s residue in the pistachio nuts by Gas chromatography/Mass spectrometry (GC/MS.The method was validated with related parameters. Recovery took place at five concentration rates (n=3 ranging from 81.40% to 93.08% with the majority of RelativeStandard Deviation being lower than 20%. Limits of detection and quantification for all the pesticides were 2µg/kg and10µg/kg, respectively. The validated method seemed to be appropriate for the analysis of pesticide’s residue in pistachio nuts. Results: Identified pesticides included Fenitrothion, Carbaryl and Diazinon. Detectable pesticide’s residue existed in 10% (5 samples of the samples. Conclusion: All the results were compared with the Iran’s National Standards and the European Maximum Residue Limits. As compared to the acceptable daily intake, the calculated daily intake of each pesticide was much lower than the standard level, which could not cause any public health problem.

  19. Measurement of plutonium and americium in molten salt residues

    International Nuclear Information System (INIS)

    Haas, F.X.; Lawless, J.L.; Herren, W.E.; Hughes, M.E.

    1979-01-01

    The measurement of plutonium and americium in molten salt residues using a segmented gamma-ray scanning device is described. This system was calibrated using artificially fabricated as well as process generated samples. All samples were calorimetered and the americium to plutonium content of the samples determined by gamma-ray spectroscopy. For the nine samples calorimetered thus far, no significant biases are present in the comparison of the segmented gamma-ray assay and the calorimetric assay. Estimated errors are of the order of 10 percent and is dependent on the americium to plutonium ratio determination

  20. Strategy utilized for assessing baseline risks to human health from K-65 and metal oxide residues stored at the Fernald Site

    Energy Technology Data Exchange (ETDEWEB)

    Harmon, J.E. [FERMCO, Cincinnati, OH (United States). Fernald Environmental Management Project; Janke, R.C.

    1995-04-01

    The U.S. Department of Energy (DOE) is responsible for cleanup activities at the Fernald Environmental Management Project (FEMP) site in southwestern Ohio. The 425-hectare site consists of a former 55-hectare Production Area, an adjacent Waste Storage Area and various support facilities. From 1952 until 1989, the FEMP processed uranium into metallic {open_quotes}feed{close_quotes} materials for other DOE facilities in the nation`s defense program. In accordance with the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA), the FEMP site is currently listed on the National Priorities List (NPL). To facilitate an expeditious cleanup effort, environmental issues associated with site cleanup are being managed under five operable units. This paper summarizes the risk assessment strategy employed to determine baseline human health risks associated with K-65 and metal oxide residues currently stored in Operable Unit 4. The K-65 and metal oxide residues were generated during the 1950s as a result of the extraction of uranium from uranium-bearing ores and concentrates. These residues are currently stored within Operable Unit 4 in concrete silos. Silos I and 2 contain approximately 6,120 cubic meters [m{sup 3}] (8,005 cubic yards [yd{sup 3}]) of K-65 residues, while silos 3 contains approximately 3890 m{sup 3} (5,080 yd{sup 3}) of cold metal oxides. These concrete silos are beyond their design life and require remedial action. The risk assessment conducted for Operable Unit 4 constitutes the first detailed human health risk assessment to be approved by the Environmental Protection Agency (EPA) for the CERCLA clean-up effort at the FEMP Site. This paper discusses the FEMP`s use of a Risk Information Quality Objective process in concert with the traditional risk assessment approach to determine baseline risk to human health and the environment posed by Operable Unit 4. A summary of the baseline risks to human health is also presented.

  1. Residue behavior and risk assessment of imidacloprid applied on greenhouse-cultivated strawberries under different application conditions.

    Science.gov (United States)

    Cang, Tao; Sun, Caixia; Zhao, Hua; Tang, Tao; Zhang, Changpeng; Yu, Ruixian; Wang, Xinquan; Wang, Qiang; Dai, Fen; Zhao, Xueping

    2018-02-01

    A risk assessment for imidacloprid applied on strawberries under different conditions was performed after residue determination using the quick, cheap, effective, rugged, and safe (QuEChERS) method. The application conditions were varied according to the applied dosage, addition of a plant oil or organosilicon surfactant, water volume, and sprayer type. The degradation dynamics of imidacloprid on strawberries followed first-order kinetics. At applied doses of 30-60 g a.i. ha -1 , the half-lives of imidacloprid were 2.89-3.46, 1.98-3.65, and 2.57-2.77 days after application without a surfactant or with a plant oil or organosilicon surfactant, respectively. For water volumes of 112.5, 225, 450, 675, and 900 L ha -1 , the half-lives of imidacloprid applied in the presence of the plant oil surfactant were 3.30, 7.70, 5.33, 7.70, and 6.30 days, respectively. The half-lives after application with a knapsack mist duster, electric sprayer, and manual sprayer were 2.16, 5.77, and 7.70 days, respectively. The health risk assessment revealed risk quotients less than 1 in all cases, indicating that the application of imidacloprid poses a low health risk to humans after a pre-harvest interval of 10 days under our application conditions. The risk assessment results can provide reference data for setting a reasonable maximum residue limit for imidacloprid on strawberries in China.

  2. Wide-band residual phase-noise measurements on 40-GHz monolithic mode-locked lasers

    DEFF Research Database (Denmark)

    Larsson, David; Hvam, Jørn Märcher

    2005-01-01

    We have performed wide-band residual phase-noise measurements on semiconductor 40-GHz mode-locked lasers by employing electrical waveguide components for the radio-frequency circuit. The intrinsic timing jitters of lasers with one, two, and three quantum wells (QW) are compared and our design......-QW laser. There is good agreement between the measured results and existing theory....

  3. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan; Fidelis, Krzysztof; Tramontano, Anna; Kryshtafovych, Andriy

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures

  4. Shutdown risk analysis for a BWR plant (residual heat removal systems)

    International Nuclear Information System (INIS)

    Rebollo Garcia, C.; Merino Teillet, A.; Cerezo, L.

    1994-01-01

    This report analyses the different risk situations which may arise during refuelling outage at Cofrentes NPP. The most critical situations are determined in terms of the small amount of coolant available and the lowest number of heat removal and water make-up systems available. The available times before the boiling point of the coolant is reached and the subsequent moment when the fuel elements are left uncovered in the event of the failure of the normal heat removal functions are determined. The analysis identifies the alternative systems which can be used besides those required by the technical specification and their capacity for residual heat removal and coolant make-up functions. (Author)

  5. Polychlorinated Biphenyls (PCB) Residue Effects Database

    Data.gov (United States)

    U.S. Environmental Protection Agency — The PCB Residue Effects (PCBRes) Database was developed to assist scientists and risk assessors in correlating PCB and dioxin-like compound residues with toxic...

  6. Characterizing chronic and acute health risks of residues of veterinary drugs in food: latest methodological developments by the joint FAO/WHO expert committee on food additives.

    Science.gov (United States)

    Boobis, Alan; Cerniglia, Carl; Chicoine, Alan; Fattori, Vittorio; Lipp, Markus; Reuss, Rainer; Verger, Philippe; Tritscher, Angelika

    2017-11-01

    The risk assessment of residues of veterinary drugs in food is a field that continues to evolve. The toxicological end-points to be considered are becoming more nuanced and in light of growing concern about the development of antimicrobial resistance, detailed analysis of the antimicrobial activity of the residues of veterinary drugs in food is increasingly incorporated in the assessment. In recent years, the Joint FAO/WHO Expert Committee on Food Additives (JECFA) has refined its approaches to provide a more comprehensive and fit-for-purpose risk assessment. This publication describes in detail the consideration of acute and chronic effects, the estimation of acute and chronic dietary exposure, current approaches for including microbiological endpoints in the risk assessment, and JECFA's considerations for the potential effects of food processing on residues from veterinary drugs. JECFA now applies these approaches in the development of health-based guidance values (i.e. safe exposure levels) for residues of veterinary drugs. JECFA, thus, comprehensively addresses acute and chronic risks by using corresponding estimates for acute and chronic exposure and suitable correction for the limited bioavailability of bound residues by the Gallo-Torres model. On a case-by-case basis, JECFA also considers degradation products that occur from normal food processing of food containing veterinary drug residues. These approaches will continue to be refined to ensure the most scientifically sound basis for the establishment of health-based guidance values for veterinary drug residues.

  7. Monitoring, exposure and risk assessment of sulfur dioxide residues in fresh or dried fruits and vegetables in China.

    Science.gov (United States)

    Lou, Tiantian; Huang, Weisu; Wu, Xiaodan; Wang, Mengmeng; Zhou, Liying; Lu, Baiyi; Zheng, Lufei; Hu, Yinzhou

    2017-06-01

    Sulfur dioxide residues in 20 kinds of products collected from 23 provinces of China (Jilin, Beijing, Shanxi, Shandong, Henan, Hebei, Jiangsu, Anhui, Shanghai, Zhejiang, Fujian, Guangdong, Guangxi, Yunnan, Guizhou, Hunan, Hubei, Chongqing, Sichuan, Gansu, Neimenggu, Xinjiang and Hainan) were analysed, and a health risk assessment was performed. The detection rates of sulfur dioxide residues in fresh vegetables, fresh fruits, dried vegetables and dried fruits were 11.1-95.9%, 12.6-92.3%, 70.3-80.0% and 26.0-100.0%, respectively; the mean concentrations of residues were 2.7-120.8, 3.8-35.7, 26.9-99.1 and 12.0-1120.4 mg kg -1 , respectively. The results indicated that fresh vegetables and dried products are critical products; the daily intakes (EDIs) for children were higher than others; the hazard indexes (HI) for four groups were 0.019-0.033, 0.001-0.005, 0.007-0.016 and 0.002-0.005 at P50, respectively. But the HI was more than 1 at P99 by intake dried fruits and vegetables. Although the risk for consumers was acceptable on the whole, children were the most vulnerable group. Uncertainty and sensitivity analyses indicated that the level of sulfur dioxide residues was the most influential variable in this model. Thus, continuous monitoring and stricter regulation of sulfites using are recommended in China.

  8. Measurement of residual stress in a cylinder by x-ray under the consideration of its penetration depth

    International Nuclear Information System (INIS)

    Doi, Osamu; Ukai, Takayoshi

    1983-01-01

    The authors propose an exact theory of residual stress measurement by successive thin layer removal in a hollow cylinder under the consideration of the contribution of residual stress within a definite subsurface, and show an example of its application. (author)

  9. Non-destructive measurement of residual stresses in U-0.8 wt.% Ti by neutron diffraction

    International Nuclear Information System (INIS)

    Salinas-Rodriguez, A.; Root, J.H.; Holden, T.M.; Macewen, S.R.; Ludtka, G.M.

    1990-01-01

    The macroscopic residual stress distribution in γ-quenched and stress levelled U-0.8wt% Ti alloy tubes was studied using neutron diffraction techniques. Residual strains were evaluated from the difference in d-spacings measured in the tubes and in small reference samples machined from each tube. Residual stresses were calculated with the isotropic bulk value of the elastic constraints for polycrystalline α-U. Quenching from the γ field resulted in a nearly equi-biaxial stress state at every point across the wall thickness of the tube. The magnitude of the radial stress was very small compared with that of the axial and hoop stresses which were compressive at the surfaces and tensile in the interior. Stress levelling relieved almost completely the hoop residual stress without affecting the radial stress. The axial residual stress becomes tensile through the wall thickness and remains constant at about 20% of its magnitude in the as-quenched condition

  10. Global assessment of river flood protection benefits and corresponding residual risks under climate change

    Science.gov (United States)

    Lim, Wee Ho; Yamazaki, Dai; Koirala, Sujan; Hirabayashi, Yukiko; Kanae, Shinjiro; Dadson, Simon J.; Hall, Jim W.

    2016-04-01

    Global warming increases the water-holding capacity of the atmosphere and this could lead to more intense rainfalls and possibly increasing natural hazards in the form of flooding in some regions. This implies that traditional practice of using historical hydrological records alone is somewhat limited for supporting long-term water infrastructure planning. This has motivated recent global scale studies to evaluate river flood risks (e.g., Hirabayashi et al., 2013, Arnell and Gosling, 2014, Sadoff et al., 2015) and adaptations benefits (e.g., Jongman et al., 2015). To support decision-making in river flood risk reduction, this study takes a further step to examine the benefits and corresponding residual risks for a range of flood protection levels. To do that, we channelled runoff information of a baseline period (forced by observed hydroclimate conditions) and each CMIP5 model (historic and future periods) into a global river routing model called CaMa-Flood (Yamazaki et al., 2011). We incorporated the latest global river width data (Yamazaki et al., 2014) into CaMa-Flood and simulate the river water depth at a spatial resolution of 15 min x 15 min. From the simulated results of baseline period, we use the annual maxima river water depth to fit the Gumbel distribution and prepare the return period-flood risk relationship (involving population and GDP). From the simulated results of CMIP5 model, we also used the annual maxima river water depth to obtain the Gumbel distribution and then estimate the exceedance probability (historic and future periods). We apply the return period-flood risk relationship (above) to the exceedance probability and evaluate the flood protection benefits. We quantify the corresponding residual risks using a mathematical approach that is consistent with the modelling structure of CaMa-Flood. Globally and regionally, we find that the benefits of flood protection level peak somewhere between 20 and 500 years; residual risks diminish

  11. Environmental dredging residual generation and management.

    Science.gov (United States)

    Patmont, Clay; LaRosa, Paul; Narayanan, Raghav; Forrest, Casey

    2018-05-01

    The presence and magnitude of sediment contamination remaining in a completed dredge area can often dictate the success of an environmental dredging project. The need to better understand and manage this remaining contamination, referred to as "postdredging residuals," has increasingly been recognized by practitioners and investigators. Based on recent dredging projects with robust characterization programs, it is now understood that the residual contamination layer in the postdredging sediment comprises a mixture of contaminated sediments that originate from throughout the dredge cut. This mixture of contaminated sediments initially exhibits fluid mud properties that can contribute to sediment transport and contamination risk outside of the dredge area. This article reviews robust dredging residual evaluations recently performed in the United States and Canada, including the Hudson River, Lower Fox River, Ashtabula River, and Esquimalt Harbour, along with other projects. These data better inform the understanding of residuals generation, leading to improved models of dredging residual formation to inform remedy evaluation, selection, design, and implementation. Data from these projects confirm that the magnitude of dredging residuals is largely determined by site conditions, primarily in situ sediment fluidity or liquidity as measured by dry bulk density. While the generation of dredging residuals cannot be avoided, residuals can be successfully and efficiently managed through careful development and implementation of site-specific management plans. Integr Environ Assess Manag 2018;14:335-343. © 2018 The Authors. Integrated Environmental Assessment and Management Published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2018 The Authors. Integrated Environmental Assessment and Management Published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).

  12. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures being the precision in recognizing contacts and the difference between the distribution of distances in the subset of predicted contact pairs versus all pairs of residues in the structure. The emphasis is placed on the prediction of long-range contacts (i.e., contacts between residues separated by at least 24 residues along sequence) in target proteins that cannot be easily modeled by homology. Although there is considerable activity in the field, the current analysis reports no discernable progress since CASP8.

  13. Measurement of conformational constraints in an elastin-mimetic protein by residue-pair selected solid-state NMR

    International Nuclear Information System (INIS)

    Hong, Mei; McMillan, R. Andrew; Conticello, Vincent P.

    2002-01-01

    We introduce a solid-state NMR technique for selective detection of a residue pair in multiply labeled proteins to obtain site-specific structural constraints. The method exploits the frequency-offset dependence of cross polarization to achieve 13 CO i → 15 N i → 13 Cα i transfer between two residues. A 13 C, 15 N-labeled elastin mimetic protein (VPGVG) n is used to demonstrate the method. The technique selected the Gly3 Cα signal while suppressing the Gly5 Cα signal, and allowed the measurement of the Gly3 Cα chemical shift anisotropy to derive information on the protein conformation. This residue-pair selection technique should simplify the study of protein structure at specific residues

  14. Environmental insecticide residues from tsetse fly control measures in Uganda

    International Nuclear Information System (INIS)

    Sserunjoji-Sebalija, J.

    1976-01-01

    Up to June 1974 areas in Uganda totalling 8600km 2 have been successfully reclaimed from tsetse fly infestation by ground spray of 3% dieldrin water emulsions. A search for equally effective but less persistent and toxic compounds against tsetse flies has been unsuccessful. Fourteen insecticide formulations have been tested for their persistence on tree bark surfaces and, therefore, their availability and toxicity to the target tsetse flies. Only those compounds with a high immediate insecticidal activity (some higher than dieldrin) like endosulfan, Chlorfenvinphos and propoxur could merit further consideration in tsetse control. While some were toxic to tsetse as fresh deposits, they lacked sufficient persistence. A study of the environmental implication from the continued use of the highly persistent and toxic dieldrin has provided useful data on residues likely to be found both in terrestrial and aquatic fauna and flora. These are generally low. Moreover, there is evidence of degradation in some fish species (Protopterus aethiopicus and Clarias). Also, dilution factors and adsorption involving the muddy nature of water run-off, etc., and controlled burning of grasses after tsetse eradication would tend to inactivate the residual insecticide and protect aquatic systems. The general findings have indicated less risk than anticipated of the environmental contamination from tsetse control by application of persistent and toxic insecticides. (author)

  15. Applications of bauxite residue: A mini-review.

    Science.gov (United States)

    Verma, Ajay S; Suri, Narendra M; Kant, Suman

    2017-10-01

    Bauxite residue is the waste generated during alumina production by Bayer's process. The amount of bauxite residue (40-50 wt%) generated depends on the quality of bauxite ore used for the processing. High alkalinity and high caustic content in bauxite residue causes environmental risk for fertile soil and ground water contamination. The caustic (NaOH) content in bauxite residue leads to human health risks, like dermal problems and irritation to eyes. Moreover, disposal of bauxite residue requires a large area; such problems can only be minimised by utilising bauxite residue effectively. For two decades, bauxite residue has been used as a binder in cement industries and filler/reinforcement for composite materials in the automobile industry. Valuable metals and oxides, like alumina (Al 2 O 3 ), titanium oxide (TiO 2 ) and iron oxide Fe 2 O 3 , were extracted from bauxite residue to reduce waste. Bauxite residue was utilised in construction and structure industries to make geopolymers. It was also used in the making of glass-ceramics and a coating material. Recently bauxite residue has been utilised to extract rare earth elements like scandium (Sc), yttrium (Y), lanthanum (La), cerium (Ce), neodymium (Nd) and dysprosium (Dy). In this review article, the mineralogical characteristics of bauxite residue are summarised and current progresses on utilisation of bauxite residue in different fields of science and engineering are presented in detail.

  16. Residual stress measurement inside a dissimilar metal weld mock-up of the pressurizer safety and relief nozzle

    International Nuclear Information System (INIS)

    Campos, Wagner R.C.; Rabello, Emerson G.; Silva, Luiz L.; Mansur, Tanius R.; Martins, Ketsia S.

    2015-01-01

    Residual stresses are present in materials or structural component in the absence of external loads or changes in temperatures. The most common causes of residual stresses being present are the manufacturing or assembling processes. All manufacturing processes, such as casting, welding, machining, molding, heat treatment, among others, introduces residual stresses into the manufactured object. The residual stresses effects could be beneficial or detrimental, depending on its distribution related to the component or structure, its load service and if it is compressive or tensile. In this work, the residual strains and stresses inside a mock-up that simulates the safety and relief nozzle of Angra 1 Nuclear Power Plant pressurizer were studied. The current paper presents a blind hole-drilling method residual stress measurements both at the inner surface of dissimilar metal welds of dissimilar metal weld nozzle mock-up. (author)

  17. Residual stress measurement inside a dissimilar metal weld mock-up of the pressurizer safety and relief nozzle

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Wagner R.C.; Rabello, Emerson G.; Silva, Luiz L.; Mansur, Tanius R., E-mail: wrcc@cdtn.br, E-mail: egr@cdtn.br, E-mail: silvall@cdtn.br, E-mail: tanius@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte (Brazil). Servico de Integridade Estrutural; Martins, Ketsia S., E-mail: ketshinoda@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Nelo Horizonte (Brazil). Departamento de Engenharia Metalurgica

    2015-07-01

    Residual stresses are present in materials or structural component in the absence of external loads or changes in temperatures. The most common causes of residual stresses being present are the manufacturing or assembling processes. All manufacturing processes, such as casting, welding, machining, molding, heat treatment, among others, introduces residual stresses into the manufactured object. The residual stresses effects could be beneficial or detrimental, depending on its distribution related to the component or structure, its load service and if it is compressive or tensile. In this work, the residual strains and stresses inside a mock-up that simulates the safety and relief nozzle of Angra 1 Nuclear Power Plant pressurizer were studied. The current paper presents a blind hole-drilling method residual stress measurements both at the inner surface of dissimilar metal welds of dissimilar metal weld nozzle mock-up. (author)

  18. Linking Energy- and Land-Use Systems: Energy Potentials and Environmental Risks of Using Agricultural Residues in Tanzania

    Directory of Open Access Journals (Sweden)

    Julia C. Terrapon-Pfaff

    2012-02-01

    Full Text Available This paper attempts to assess whether renewable energy self-sufficiency can be achieved in the crop production and processing sector in Tanzania and if this could be accomplished in an environmentally sustainable manner. In order to answer these questions the theoretical energy potential of process residues from commercially produced agricultural crops in Tanzania is evaluated. Furthermore, a set of sustainability indicators with focus on environmental criteria is applied to identify risks and opportunities of using these residues for energy generation. In particular, the positive and negative effects on the land-use-system (soil fertility, water use and quality, biodiversity, etc. are evaluated. The results show that energy generation with certain agricultural process residues could not only improve and secure the energy supply but could also improve the sustainability of current land-use practices.

  19. Implementation of secondary bacterial culture testing of platelets to mitigate residual risk of septic transfusion reactions.

    Science.gov (United States)

    Bloch, Evan M; Marshall, Christi E; Boyd, Joan S; Shifflett, Lisa; Tobian, Aaron A R; Gehrie, Eric A; Ness, Paul M

    2018-04-01

    Bacterial contamination of platelets remains a major transfusion-associated risk despite long-standing safety measures in the United States. We evaluated an approach using secondary bacterial culture (SBC) to contend with residual risk of bacterial contamination. Phased implementation of SBC was initiated in October 2016 for platelets (all apheresis collected) received at our institution from the blood donor center (Day 3 post collection). Platelet products were sampled aseptically (5 mL inoculated into an aerobic bottle [BacT/ALERT BPA, BioMerieux, Inc.]) by the blood bank staff upon receipt, using a sterile connection device and sampling kit. The platelet sample was inoculated into an aerobic blood culture bottle and incubated at 35°C for 3 days. The cost of SBC was calculated on the basis of consumables and labor costs at time of implementation. In the 13 months following implementation (October 6, 2016, to November 30, 2017), 23,044/24,653 (93.47%) platelet products underwent SBC. A total of eight positive cultures were detected (incidence 1 in 2881 platelet products), seven of which were positive within 24 hours of SBC. Coagulase negative Staphyloccus spp. were identified in four cases. Five of the eight cases were probable true positive (repeat reactive) and interdicted (cost per averted case was US$77,935). The remaining three cases were indeterminate. No septic transfusion reactions were reported during the observation period. We demonstrate the feasibility of SBC of apheresis platelets to mitigate bacterial risk. SBC is lower cost than alternative measures (e.g., pathogen reduction and point-of-release testing) and can be integrated into workflow at hospital transfusion services. © 2018 AABB.

  20. Corrosion failure due to flux residues in an electronic add-on device

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Minzari, Daniel; Rathinavelu, Umadevi

    2010-01-01

    of the electrochemical behavior metallic materials (alloys) used in the switch and risk of electrochemical migration (ECM) between the switch components in presence of flux residues was also carried out. Investigations included potentiodynamic polarization measurements on the switch electrodes using a micro......-electrochemical technique, in situ ECM studies, and scanning electron microscopy (SEM). Failure of the switches was found to be either due to the flux residue acting as an nsulating layer or as a corrosion accelerator causing ECM....

  1. Improving risk assessments for manufactured gas plant soils by measuring PAH availability.

    Science.gov (United States)

    Stroo, Hans F; Nakles, David V; Kreitinger, Joseph P; Loehr, Raymond C; Hawthorne, Steven B; Luthy, Richard G; Holman, Hoi-Ying; LaPierre, Adrienne

    2005-07-01

    Remediation of soils at oil-gas manufactured gas plant (MGP) sites is driven primarily by the human health risks posed by the carcinogenic polycyclic aromatic hydrocarbons (PAHs), particularly benzo[a]pyrene (BaP), that are associated with lampblack residues. Although PAHs on lampblack are tightly sorbed, risk assessments do not account for this reduced availability. A multi-investigator study of 7 oil-gas MGP site soil samples demonstrated that the dermal and ingestion absorption factors are far lower than current default assumptions used in risk assessments. Using these sample-specific absorption factors in standard risk assessment equations increased risk-based cleanup levels by a factor of 72 on average (with a range from 23 to 142 times the default level). The rapidly released fraction of the BaP in each sample, as measured by supercritical fluid extraction, was closely correlated (r2 = 0.96) to these calculated cleanup levels. The weight of evidence developed during this research indicates that the risks posed by PAHs on lampblack are far less than assumed when using default absorption factors and that a tiered evaluation protocol employing chemical analyses, chemical release data, and in vitro bioassays can be used to establish more realistic site-specific criteria.

  2. Evaluation of the effectiveness of the three-dimensional residual stresses method based on the eigenstrain methodology via x-ray measurements

    International Nuclear Information System (INIS)

    Ogawa, Masaru; Ishii, Takehiro; Furusako, Seiji

    2015-01-01

    In order to prevent fractures caused by fatigue or stress corrosion cracking in welded structures, it is important to predict crack propagation for cracks observed during in-service inspections. However, it is difficult to evaluate three-dimensional welding residual stresses non-destructively. Today, it is possible to measure residual stresses just on surface by X-ray diffraction. Neutron diffraction makes it possible to measure welding residual stresses non-destructively even in the thickness direction but it is only available in special irradiation facilities. Therefore, it is impossible to use neutron diffraction as an on-site measurement technique. As non-destructive method of three-dimensional welding residual stresses based on the eigenstrain methodology, the bead flush method has been proposed. In this method, three-dimensional welding residual stresses are calculated by an elastic FEM (Finite Element Method) analysis from eigenstrain distributions which are estimated by an inverse analysis from released strains by strain gauges in the removal of the weld reinforcement. Here, the removal of the excess metal contributes inhibition of crack initiation. Therefore, the bead flush method is a non-destructive technique essentially. However, estimation accuracy of this method becomes relatively poor when processing strains are added on the machined surface. The first author has been developed the bead flush method to be free from the influence of the processing strains. In this method, eigenstrains are estimated not from released strains but from residual strains on surface by X-ray diffraction. In this study, welding residual stresses on the bottom surface in an actual welded plate are estimated from elastic strains measured on the top surface using this method. To evaluate estimation accuracy, estimated residual stresses on the bottom surface are compared with residual stresses measured by X-ray diffraction. Here, eigenstrain distributions not only in the welding

  3. Risk measurement with equivalent utility principles

    NARCIS (Netherlands)

    Denuit, M.; Dhaene, J.; Goovaerts, M.; Kaas, R.; Laeven, R.

    2006-01-01

    Risk measures have been studied for several decades in the actuarial literature, where they appeared under the guise of premium calculation principles. Risk measures and properties that risk measures should satisfy have recently received considerable attention in the financial mathematics

  4. A strategy for accommodating residual stresses in the assessment of repair weldments based upon measurement of near surface stresses

    International Nuclear Information System (INIS)

    Mcdonald, E.J.; Hallam, K.R.; Flewitt, P.E.J.

    2005-01-01

    On many occasions repairs are undertaken to ferritic steel weldments on plant either during construction or to remove service induced defects. These repaired weldments are subsequently put into service with or without a post-weld heat treatment. In either case, but particularly for the latter, there is a need to accommodate the associated residual stresses in structural integrity assessments such as those based upon the R6 failure avoidance procedure. Although in some circumstances the residual macro-stresses developed within weldments of components and structures can be calculated this is not so readily achieved in the case of residual stresses introduced by repair welds. There is a range of physical and mechanical techniques available to undertake the measurement of macro-residual stresses. Of these X-ray diffraction has the advantage that it is essentially non-destructive and offers the potential for evaluating stresses, which exist in the near surface layer. Although for many structural integrity assessments both the magnitude and distribution of residual stresses have to be accommodated it is not practical to make destructive measurements on weld repaired components and structures to establish the through section distribution of stresses. An approach is to derive a description of the appropriate macro-stresses by a combination of measurement and calculation on trial ferritic steel repair weldments. Surface measurements on the plant can then be made to establish the relationship between the repaired component or structure and the trial weld and thereby improve confidence in predicted stresses and their distribution from the near-surface measured values. Hence X-ray diffraction measurements at the near-surface of the plant weldment can be used to underwrite the quality of the repair by confirming the magnitude and distribution of residual stresses used for the integrity assessment to demonstrate continued safe operation

  5. A study for high accuracy measurement of residual stress by deep hole drilling technique

    Science.gov (United States)

    Kitano, Houichi; Okano, Shigetaka; Mochizuki, Masahito

    2012-08-01

    The deep hole drilling technique (DHD) received much attention in recent years as a method for measuring through-thickness residual stresses. However, some accuracy problems occur when residual stress evaluation is performed by the DHD technique. One of the reasons is that the traditional DHD evaluation formula applies to the plane stress condition. The second is that the effects of the plastic deformation produced in the drilling process and the deformation produced in the trepanning process are ignored. In this study, a modified evaluation formula, which is applied to the plane strain condition, is proposed. In addition, a new procedure is proposed which can consider the effects of the deformation produced in the DHD process by investigating the effects in detail by finite element (FE) analysis. Then, the evaluation results obtained by the new procedure are compared with that obtained by traditional DHD procedure by FE analysis. As a result, the new procedure evaluates the residual stress fields better than the traditional DHD procedure when the measuring object is thick enough that the stress condition can be assumed as the plane strain condition as in the model used in this study.

  6. Residual stress measurement in worked and heat treated steel by X-ray diffractometry

    International Nuclear Information System (INIS)

    Sinha, V.K.; Godaba, V.S.

    2008-01-01

    Investigations were made for residual stress measurement by X-ray diffractometry in the 1.14% C, 0.46% Mn, 0.16% Si, 0.11% S and 0.04% P steel samples subjected to inhomogeneous plastic deformation (cold upsetting in the range 7.7-21%), thermal gradient (quenching from 630 deg. C) and phase transformation (quenching from 850 deg. C), respectively. The results indicated that compressive residual stress at the surface increased in the samples with increasing deformation acquiring values in the range, -269.5 MPa to -374.7 MPa. In the samples quenched from 630 deg. C, the thermal stresses acquired increasing values in the range -83.9 MPa (compressive) to -188.1 MPa (compressive) with increased cooling rate. In the samples quenched from 850 deg. C, volume increase on account of austenite to martensite phase transformation ultimately dominated the thermal contraction resulting in residual stress at the surface from -329.3 MPa (compressive) to +61.7 MPa (tensile)

  7. Standard test method for determining the effective elastic parameter for X-ray diffraction measurements of residual stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a procedure for experimentally determining the effective elastic parameter, Eeff, for the evaluation of residual and applied stresses by X-ray diffraction techniques. The effective elastic parameter relates macroscopic stress to the strain measured in a particular crystallographic direction in polycrystalline samples. Eeff should not be confused with E, the modulus of elasticity. Rather, it is nominally equivalent to E/(1 + ν) for the particular crystallographic direction, where ν is Poisson's ratio. The effective elastic parameter is influenced by elastic anisotropy and preferred orientation of the sample material. 1.2 This test method is applicable to all X-ray diffraction instruments intended for measurements of macroscopic residual stress that use measurements of the positions of the diffraction peaks in the high back-reflection region to determine changes in lattice spacing. 1.3 This test method is applicable to all X-ray diffraction techniques for residual stress measurem...

  8. Plastic deformation, residual stress, and crystalline texture measurements for in-process characterization of FCC metal alloys

    International Nuclear Information System (INIS)

    Ruud, C.O.; Jacobs, M.E.; Weedman, S.D.; Snoha, D.J.

    1989-01-01

    This paper describes the results of several on-going investigations on the measurement of plastic deformation, residual stress, and crystalline texture in nickel, copper, and aluminum base alloys by x-ray diffraction techniques. X-ray diffraction techniques have been shown to be effective in the measurement of plastic deformation, residual stress, and crystalline texture in FCC metals, from the breadth, position, and intensity of the x-ray diffraction peaks. The Ruud-Barrett position-sensitive scintillation detector has been demonstrated to be fast, non-contacting, and tolerant of detector to component distance variation -- necessary requirements for cost-effective in-process inspection of materials

  9. Measurement of heat treatment induced residual stresses by using ESPI combined with hole-drilling method

    Directory of Open Access Journals (Sweden)

    Jie Cheng

    2010-08-01

    Full Text Available In this study, residual stresses in heat treated specimen were measured by using ESPI (Electronic Speckle-Pattern Interferometry combined with the hole-drilling method. The specimen, made of SUS 304 austenitic stainless steel, was quenched and water cooled to room temperature. Numerical simulation using a hybrid FDM/FEM package was also carried out to simulate the heat treatment process. As a result, the thermal stress fields were obtained from both the experiment and the numerical simulation. By comparision of stress fields, results from the experimental method and numerical simulation well agreed to each other, therefore, it is proved that the presented experimental method is applicable and reliable for heat treatment induced residual stress measurement.

  10. A comparison of conventional and prototype nondestructive measurements on molten salt extraction residues

    International Nuclear Information System (INIS)

    Longmire, V.L.; Hurd, J.R.; Sedlacek, W.E.; Scarborough, A.M.

    1987-01-01

    Fourteen molten salt extraction residues were assayed by conventional and prototype nondestructive assay (NDA) techniques to be compared with destructive chemical analysis in an effort to identify acceptable NDA measurement methods for this matrix. NDA results on seven samples and destructive results on four samples are presented

  11. Residual stresses in as-sprayed and heat treated TBCs : measurements and FEM calculations

    NARCIS (Netherlands)

    Koolloos, M.F.J.; Houben, J.M.

    2000-01-01

    The first part of this paper concerns measurement of through-thickness residual stresses in TBCs by the hole-drilling method. The influences of top coat thickness and different thermal histories (furnace and burner rig) were determined. Low tensile stresses prevailed in the as-sprayed state, and low

  12. Measurement of conformational constraints in an elastin-mimetic protein by residue-pair selected solid-state NMR

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Mei [Iowa State University, Department of Chemistry (United States)], E-mail: mhong@iastate.edu; McMillan, R. Andrew; Conticello, Vincent P. [Emory University, Department of Chemistry (United States)

    2002-02-15

    We introduce a solid-state NMR technique for selective detection of a residue pair in multiply labeled proteins to obtain site-specific structural constraints. The method exploits the frequency-offset dependence of cross polarization to achieve {sup 13}CO{sub i} {sup {yields}} {sup 15}N{sub i} {sup {yields}} {sup 13}C{alpha}{sub i} transfer between two residues. A {sup 13}C, {sup 15}N-labeled elastin mimetic protein (VPGVG){sub n} is used to demonstrate the method. The technique selected the Gly3 C{alpha} signal while suppressing the Gly5 C{alpha} signal, and allowed the measurement of the Gly3 C{alpha} chemical shift anisotropy to derive information on the protein conformation. This residue-pair selection technique should simplify the study of protein structure at specific residues.

  13. In-situ X-ray residual stress measurement on a peened alloy 600 weld metal at elevated temperature under tensile load

    International Nuclear Information System (INIS)

    Yunomura, Tomoaki; Maeguchi, Takaharu; Kurimura, Takayuki

    2014-01-01

    In order to verify stability of residual stress improvement effect of peeing for mitigation of stress corrosion cracking in components of PWR plant, relaxation behavior of residual stress induced by water jet peening (WJP) on surface of alloy 600 weld metal (alloy 132) was investigated by in-situ X-ray residual stress measurement under thermal aging and stress condition considered for actual plant operation. Surface residual stress change was observed at the early stage of thermal aging at 360°C, but no significant further stress relaxation was observed after that. Applied stress below yield stress does not significantly affect stress relaxation behavior of surface residual stress. For the X-ray residual stress measurement, X-ray stress constant at room temperature for alloy 600 was determined experimentally with several surface treatment and existence of applied strain. The X-ray stress constant at elevated temperatures were extrapolated theoretically based on the X-ray stress constant at room temperature for alloy 600. (author)

  14. Effect of Young's modulus evolution on residual stress measurement of thermal barrier coatings by X-ray diffraction

    International Nuclear Information System (INIS)

    Chen, Q.; Mao, W.G.; Zhou, Y.C.; Lu, C.

    2010-01-01

    Subjected to thermal cycling, the apparent Young's modulus of air plasma-sprayed (APS) 8 wt.% Y 2 O 3 -stabilized ZrO 2 (8YSZ) thermal barrier coatings (TBCs) was measured by nanoindentation. Owing to the effects of sintering and porous microstructure, the apparent Young's modulus follows a Weibull distribution and changes from 50 to 93 GPa with an increase of thermal cycling. The evolution of residual stresses in the top coating of an 8YSZ TBC system was determined by X-ray diffraction (XRD). The residual stresses derived from the XRD data are well consistent with that obtained by the Vickers indention. It is shown that the evolution of Young's modulus plays an important role in improving the measurement precision of residual stresses in TBCs by XRD.

  15. Residual stress relaxation measurements across interfaces at macro-and micro-scales using slitting and DIC

    Energy Technology Data Exchange (ETDEWEB)

    Blair, A; Daynes, N; Hamilton, D; Horne, G; Hodgson, D Z L; Shterenlikht, A [Department of Mechanical Engineering, University of Bristol, Bristol BS8 1TR (United Kingdom); Heard, P J; Scott, T B, E-mail: mexas@bristol.ac.u [Interface Analysis Centre, University of Bristol, Bristol BS2 8BS (United Kingdom)

    2009-08-01

    In this paper digital image correlation is used to measure relaxation of residual stresses across an interface. On the macro scale the method is applied to a tri-layer bonded aluminium sample, where the middle layer is in tension and the top and the bottom layers are in compression. High contrast speckle pattern was sprayed onto the surface. The relaxation was done with the slitting saw. Three dimensional image correlation was used. On the micro scale the technique was applied to a heat treated large grain brass loaded in tension. Mechanical and electro polishing was used for surface preparation. A focused ion beam was used for slitting across a grain boundary and for imaging. Grain orientation was measured using electron back-scattering diffraction. Two dimensional image correlation was employed. In all macro- and micro-scale experiments the range of measured relaxation was sub-pixel, almost at the limit of the resolution of the image correlation algorithms. In the macro-scale experiments, the limiting factor was low residual stress, due to low shear strength of the Araldite glue used for bonding. Finite element simulation of the relaxation agreed only qualitatively with the experimental results at both size scales. The methodology is intended for use with inverse methods, i.e. the measured relaxation is applied as the boundary conditions to an appropriate FE model which produces stresses equal to the relaxed residual stresses, but with opposite sign. The main conclusion is that the digital image correlation method could be used to measure relaxation caused by slitting in heterogeneous materials and structures at both macro- and micro-scales. However, the repeatability of the techniques needs to be improved before residual stresses can be determined confidently. Acknowledgments The authors gratefully acknowledge Airbus UK for provision of materials. They thank Dr Richard Burguete, Airbus UK, and Prof Peter Flewitt, Department of Physics, University of Bristol, for

  16. Residual stress relaxation measurements across interfaces at macro-and micro-scales using slitting and DIC

    International Nuclear Information System (INIS)

    Blair, A; Daynes, N; Hamilton, D; Horne, G; Hodgson, D Z L; Shterenlikht, A; Heard, P J; Scott, T B

    2009-01-01

    In this paper digital image correlation is used to measure relaxation of residual stresses across an interface. On the macro scale the method is applied to a tri-layer bonded aluminium sample, where the middle layer is in tension and the top and the bottom layers are in compression. High contrast speckle pattern was sprayed onto the surface. The relaxation was done with the slitting saw. Three dimensional image correlation was used. On the micro scale the technique was applied to a heat treated large grain brass loaded in tension. Mechanical and electro polishing was used for surface preparation. A focused ion beam was used for slitting across a grain boundary and for imaging. Grain orientation was measured using electron back-scattering diffraction. Two dimensional image correlation was employed. In all macro- and micro-scale experiments the range of measured relaxation was sub-pixel, almost at the limit of the resolution of the image correlation algorithms. In the macro-scale experiments, the limiting factor was low residual stress, due to low shear strength of the Araldite glue used for bonding. Finite element simulation of the relaxation agreed only qualitatively with the experimental results at both size scales. The methodology is intended for use with inverse methods, i.e. the measured relaxation is applied as the boundary conditions to an appropriate FE model which produces stresses equal to the relaxed residual stresses, but with opposite sign. The main conclusion is that the digital image correlation method could be used to measure relaxation caused by slitting in heterogeneous materials and structures at both macro- and micro-scales. However, the repeatability of the techniques needs to be improved before residual stresses can be determined confidently. Acknowledgments The authors gratefully acknowledge Airbus UK for provision of materials. They thank Dr Richard Burguete, Airbus UK, and Prof Peter Flewitt, Department of Physics, University of Bristol, for

  17. Probabilistic risk assessment of exposure to leucomalachite green residues from fish products.

    Science.gov (United States)

    Chu, Yung-Lin; Chimeddulam, Dalaijamts; Sheen, Lee-Yan; Wu, Kuen-Yuh

    2013-12-01

    To assess the potential risk of human exposure to carcinogenic leucomalachite green (LMG) due to fish consumption, the probabilistic risk assessment was conducted for adolescent, adult and senior adult consumers in Taiwan. The residues of LMG with the mean concentration of 13.378±20.56 μg kg(-1) (BFDA, 2009) in fish was converted into dose, considering fish intake reported for three consumer groups by NAHSIT (1993-1996) and body weight of an average individual of the group. The lifetime average and high 95th percentile dietary intakes of LMG from fish consumption for Taiwanese consumers were estimated at up to 0.0135 and 0.0451 μg kg-bw(-1) day(-1), respectively. Human equivalent dose (HED) of 2.875 mg kg-bw(-1) day(-1) obtained from a lower-bound benchmark dose (BMDL10) in mice by interspecies extrapolation was linearly extrapolated to oral cancer slope factor (CSF) of 0.035 (mgkg-bw(-1)day(-1))(-1) for humans. Although, the assumptions and methods are different, the results of lifetime cancer risk varying from 3×10(-7) to 1.6×10(-6) were comparable to those of margin of exposures (MOEs) varying from 410,000 to 4,800,000. In conclusions, Taiwanese fish consumers with the 95th percentile LADD of LMG have greater risk of liver cancer and need to an action of risk management in Taiwan. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Evaluation of cladding residual stresses in clad blocks by measurements and numerical simulations

    International Nuclear Information System (INIS)

    Dupas, P.; Moinereau, D.

    1996-01-01

    Reactor pressure vessels are internally clad with austenitic stainless steel. This welding operation generates residual stresses which can have an important role in integrity assessments. In order to evaluate these stresses, an experimental and numerical programme has been conducted. The experiments includes cladding operations, macrographic analyses, temperature and residual stresses measurements with different methods. According to these measurements, transversal stresses (perpendicular to the welding direction) and longitudinal stresses (parallel to the welding direction) are highly tensile in stainless steel and they are compressive in the HAZ. Finite element calculations were used to simulate both welding operations and post weld heat treatment. These calculations coupled the thermal, metallurgical and mechanical aspects in a 2D representation. Different models were studied including effect of generalised plane strain, transformation plasticity, creep and tempering. The transversal stresses calculated are similar to the measured ones, but the longitudinal stresses showed to be very sensitive to the model used. As expected because of the two-dimension model, the longitudinal stresses can't be well estimated. More work is needed to improve measurements of stresses in depth (important differences appeared between the different methods). A predictive model would be also very useful to determine the thermal loading which is at present dependant on measurements. A 3D calculation appears to be necessary to evaluate longitudinal stresses. (orig.)

  19. Consideration of microstructure evolution and residual stress measurement near severe worked surface using high energy x-ray

    International Nuclear Information System (INIS)

    Hashimoto, Tadafumi; Mochizuki, Masahito; Shobu, Takahisa

    2012-01-01

    It is necessary to establish a measurement method that can evaluate accurate stress on the surface. However, the microstructure evolution takes place near the surface due to severe plastic deformation, since structural members have been superpositioned a lot of working processes to complete. As well known, a plane stress can't be assumed on the severe worked surface. Therefore we have been proposed the measurement method that can be measured the in-depth distribution of residual stress components by using high energy X-ray from a synchrotron radiation source. There is the combination of the constant penetration depth method and tri-axial stress analysis. Measurements were performed by diffraction planes for the orientation parameter Γ=0.25 of which elastic constants are nearly equal to the mechanical one. The stress components obtained must be converted to the stress components in real space by using optimization technique, since it corresponds to the weighted average stress components associated with the attenuation of X-ray in materials. The predicted stress components distribution agrees very well with the corrected one which was measured by the conventional removal method. To verify the availability of the proposed method, thermal aging variation of residual stress components on the severe worked surface under elevated temperature was investigated using specimen superpositioned working processes (i.e., welding, machining, peening). It is clarified that the residual stress components increase with thermal aging, using the diffraction planes in hard elastic constants to the bulk. This result suggests that the thermal stability of residual stress has the dependence of the diffraction plane. (author)

  20. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  1. Residual strain in the Nb-H system measured by selected area diffraction (SAD)

    International Nuclear Information System (INIS)

    Bulhoes, I.A.M.; Akune, K.; Pinatti, Dyonisio G.

    1981-07-01

    Various specimens of Nb were annealed in vacuum of 10 -3 torr for four hours at 1770 0 K. These speciments were doped with hydrogen up to 1000 ppm by weight and then were analyzed selected area diffraction. The line resolution of the electron channelling pattern was meassured for the specimens with different hydrogen content. These measurements, combined with the measurement of density, permitted one to estimate the residual strain caused by hydrogen. (Author) [pt

  2. Measuring the residual stress of transparent conductive oxide films on PET by the double-beam shadow Moiré interferometer

    Science.gov (United States)

    Chen, Hsi-Chao; Huang, Kuo-Ting; Lo, Yen-Ming; Chiu, Hsuan-Yi; Chen, Guan-Jhen

    2011-09-01

    The purpose of this research was to construct a measurement system which can fast and accurately analyze the residual stress of the flexible electronics. The transparent conductive oxide (TCO) films, tin-doped indium oxide (ITO), were deposited by radio frequency (RF) magnetron sputtering using corresponding oxide targets on PET substrate. As we know that the shadow Moiré interferometry is a useable way to measure the large deformation. So we set up a double beam shadow Moiré interferometer to measure and analyze the residual stress of TCO films on PET. The feature was to develop a mathematical model and combine the image processing software. By the LabVIEW graphical software, we could measure the distance which is between the left and right fringe on the pattern to solve the curvature of deformed surface. Hence, the residual stress could calculate by the Stoney correction formula for the flexible electronics. By combining phase shifting method with shadow Moiré, the measurement resolution and accuracy have been greatly improved. We also had done the error analysis for the system whose relative error could be about 2%. Therefore, shadow Moiré interferometer is a non-destructive, fast, and simple system for the residual stress on TCO/PET films.

  3. [Evolution of residual risk for HIV, HCV and HBV, from 1999 to 2010, in blood donations of the Centro Hospitalar S. João, EPE, Porto, Portugal].

    Science.gov (United States)

    Koch, Carmo; Araújo, Fernando

    2013-01-01

    Monitoring the residual risk of transfusion-transmitted viral infections is important to evaluate the improvement achieved in the blood donation safety and to adopt policies to reduce risks. The present study calculates the incidence of the key infectious diseases, human immunodeficiency virus (HIV), hepatitis B virus (HBV) and hepatitis C virus (HCV) as well as the residual risk of transfusion-transmitted viral infections, during twelve years, 1999 through 2010. Data were analyzed over 3 periods of 4 years (1999-2002, 2003-2006 and 2007-2010). The risk estimates were compared to those previously obtained for blood donations occurred between 1991 and 1998. The study included 209 640 blood donations, from 42 634 regular, volunteers and unpaid donors. The residual risk of transfusion-transmitted infection per million donations was calculated, for each virus, through mathematical model "Incidence rate/window period", described by Schreiber et al. All donations were screened according to Portuguese legislation. In January 2001, the nucleic acid testing in minipool was implemented on all blood donations, for screening simultaneously HIV-1 and HCV ribonucleic acid (RNA) (Cobas Amplicor Ampliscreen-Roche©). This test was replaced, in January 2007, by the simultaneous screening of HBV deoxyribonucleic acid, HCV RNA and HIV-1/HIV-2 RNA, in minipool (Cobas Taqscreen MPX Test-Roche©). The residual risk of transmitting viral infections during the transfusion of blood components is very small and has declined over the years. After the implementation of the nucleic acid testing in minipool for the three viruses, the risk of giving blood during an infectious window period was estimated as follows: for human immunodeficiency virus, 1 in 1.67 million, for hepatitis C virus 1 in 3.33 million and for hepatitis B virus 1 in 526 000. During the 12 years under study, we found a decrease in residual risk for the three viruses, by a factor around five for human immunodeficiency virus

  4. Numerical simulation of residual stress in piping components at Framatome-ANP

    International Nuclear Information System (INIS)

    Gilies, P.; Franco, C.; Cipiere, M.-F.; Ould, P.

    2005-01-01

    Numerous manufacturing processes induce residual stresses and distortions in piping components and associated welds: quenching of cast pipings, machining and welding. In Pressurized Water Reactors, most of the components have a large thickness for sustaining pressure and distortions are a minor source of concern. This is not the case for residual stresses which may have a strong influence on several type of damage such as fatigue, corrosion, brittle fracture. In low toughness components, residual stress fields may contribute to ductile tearing initiation. These potential damages are mitigated after welding by stress relief heat treatment, which is applied in a systematic manner to ferritic components of the primary system in nuclear reactors. This treatment is not applied on austenitic piping for which the heat treatment temperature is limited due to the risk of sensitization and residual stresses are difficult to eliminate completely. Since on site measurements are costly and difficult to perform, numerical simulation appears to be an attractive tool for estimating residual stress distributions. Framatome-ANP is working on modelling manufacturing processes with that purpose in mind. This paper presents three kinds of applications illustrating efforts on welding, quenching and machining simulation. First a comparison is shown between computations and measurements of residual stress induced by welding of a dissimilar weld metal junction. Then numerical simulations of quenching of a cast stainless steel nozzle are presented. Finally quenching followed by machining and grinding of this cast component are considered in a full simulation of the manufacturing process. Computed distortions and residual stresses are compared with experimental measurements at different stages of the manufacturing process. (authors)

  5. The influence of texture on residual stress measurements

    International Nuclear Information System (INIS)

    Lima, N.B. de.

    1991-01-01

    A computer program to calculate the orientation distribution function (ODF) from incomplete pole figures has been developed for rolled materials with a cubic structure. This program is based on Bunge's series expansion. The use of incomplete pole figures results in the loss of orthogonality among symmetric spherical harmonic functions and makes it necessary to explicitly evaluate the integrals. The ODF has been used to quantitatively evaluate the influence of texture in determining residual stresses. This has been done by calculating theoretically the strain undergone by each cell as a function of its orientation to residual stress relationship. To test the ODF program, cold rolled Cu and Al specimens were used and to evaluate residual stresses as a function of texture, cold rolled AISI 430 and 324 specimens were used. Simulations have also be presented based on the texture for each of the materials, to verify the nature of the curve d x sin 2 ψ as a function of each stress tensor components. (author)

  6. Process for measuring the helium residual gas pressure and circuit for carrying out the process

    International Nuclear Information System (INIS)

    Schmidt, C.; Cesnak, L.

    1983-01-01

    In cryotechnic devices, the quality of the thermal insulation can be monitored by checking the pressure of the residual gas. A process is proposed in which a thin super-conducting wire or a superconducting layer acting as vacuum sensor has a heating pulse reaching the critical current applied to it, which produces a local normal conduction zone. The vacuum sensor has a measuring current of constant amount applied to it, which causes a voltage drop on its resistance during the time in which the normal conduction zone exists, the cooling time. The pressure of the residual gas is a function of the integral of the voltage drop and is measured by integrating the voltage during the cooling time. (orig./HP) [de

  7. Measuring Producers' Risk Preferences: A Global Risk Attitude Construct

    NARCIS (Netherlands)

    Pennings, J.M.E.; Garcia, P.

    2001-01-01

    In applied agricultural economic research various risk-attitude elicitation techniques are used. Here, we investigate whether risk-attitude measures rooted in the expected utility framework are related to measures rooted in the multi-item scale framework. Using a second-order factor analytical

  8. Organochlorine pesticide residues in sardinella aurita from the coastal waters of Accra-Tema, Ghana and their potential health risks

    International Nuclear Information System (INIS)

    Nyarko, E.; Botwe, B.O.; Bampoe, A.A.; Addo, S.; Armah, A.K.; Ntow, W.J.; Kelderman, P.

    2011-01-01

    Sardinella aurita and seawater samples from the Accra-Tema coast of Ghana were analysed for organochlorine (OC) pesticides using gas chromatography (GC) with electron capture detection (ECD). Residues of DDTs (p,p'-DDT, p'p'-DDE,p,p'-DDD), hexachlorocyclohexane (HCHs - α-HCH, β-HCH and γ-HCH), endosulfan (α-endosulfan, β-endosulfan, endosulfan sulphate) and heptachlor were detected in fish at average concentrations ranging from 3.0 to 1235.0 μg/kg wet wt. These residues were, however, below the detection limit in seawater samples. Significant differences (p < 0.05) in residue levels were also observed across sites, decreasing from Chorkor to Kpone for seven (7) of the residues that were detected in S. aurita. Evaluation of hazard ratios (HRs) and the health risk associated with OC exposure from consumption of sardinellas revealed a probability of adverse health effect due to p,p'-DDT, γ-HCH and heptachlor. Hence, p,p'-DDT, γ-HCH and heptachlor may be of particular health concern. (au)

  9. Residual stress measurements in coil, linepipe and girth welded pipe

    International Nuclear Information System (INIS)

    Law, M.; Prask, H.; Luzin, V.; Gnaeupel-Herold, T.

    2006-01-01

    Residual stresses in gas pipelines come from forming operations in producing the coil and pipe, seam welding the pipe, and girth welding pipes together to form a gas pipeline. Welding is used extensively in gas pipelines, the welds are made without post weld heat treatment. The three normal stresses were measured by neutron diffraction for three types of sample: coil, unwelded rings cut from the pipe made from this coil, and girth welded rings cut from linepipe. All three specimens came from three thicknesses of manufacture (5.4, 6.4, and 7.1 mm). The welds are manual metal arc cellulosic electrode welds made in X70 linepipe, these were measured at 5 through-thickness positions at 19 locations (from the center of the weld up to 35 mm away from the weld) with a spatial resolution of 1 mm 3 . The coil and unwelded rings were measured at the same five through-thickness positions

  10. Development of a micrometre-scale radiographic measuring method for residual stress analysis

    International Nuclear Information System (INIS)

    Moeller, D.

    1999-01-01

    The radiographic method described uses micrometre X-ray diffraction for high-resolution residual stress analysis in single crystals. The focus is on application of two x-ray optics (glass capillaries) for shaping a sufficiently fine and intensive primary beam. Due to application of a proper one-grain measuring and analysis method, the resolution results are applicable to the characteristic grain sizes of many materials. (orig.) [de

  11. MODERN RISK MEASURES FOR INDIVIDUAL HIGHER EDUCATION INVESTMENT RISK EVALUATION

    Directory of Open Access Journals (Sweden)

    Vona Mate

    2014-07-01

    Full Text Available One of the reasons why people get degree and participate in organized education is that they want to raise their human capital or signal their inner abilities to future employers by sorting themselves out. In both cases they can expect return to their investment, because they can expect higher life-time earnings than those who do not have degree. In this paper we will refer this activity as higher education investment or education investment. In this paper the investment of the state into educating their citizens will not be considered. The question of this paper will develop the findings of Vona (2014. I suggested to introduce modern risk measures because individual risk-taking became a serious question. It was considered that modern risk measures can help to solve some issues with the relation of investment and risk. However before applying some measures from a different field of science, namely investment finance and financial mathematics, to another, economics of education, there must be a very careful consideration, because there are debate over these measures applicability even on their field of science. Value at Risk is not coherent and Expected Shortfall is only one of a great deal of possible tail loss measures. For this reason it will be discussed in detail how should we should adopt the measures, what kind of data is necessary for calculating this risk measures and what kind of new insight they can bring. With the aid of a numerical example it will be shown that with expected shortfall measure we can reflect some large losses, and potential high value of diversification. We show the value at risk based measure is not coherent and this means it points out something different in this environment. It is can be an indicator of loss in opportunities for high end returns.

  12. Improvement in accuracy of the measurements of residual stresses due to circumferential welds in thin-walled pipe using Rayleigh wave method

    International Nuclear Information System (INIS)

    Akhshik, Siamak; Moharrami, Rasool

    2009-01-01

    To achieve an acceptable safety in many industrial applications such as nuclear power plants and power generation, it is extremely important to gain an understanding of the magnitudes and distributions of the residual stresses in a pipe formed by joining two sections with a girth butt weld. Most of the methods for high-accuracy measurement of residual stress are destructive. These destructive measurement methods cannot be applied to engineering systems and structures during actual operation. In this paper, we present a method based on the measurement of ultrasonic Rayleigh wave velocity variations versus the stress state for nondestructive evaluation of residual stress in dissimilar pipe welded joint. We show some residual stress profile obtained by this method. These are then compared with other profiles determined using a semi-destructive technique (hole-drilling) that makes it possible to check our results. According to the results, we also present a new method for adjusting the ultrasonic measurements to improve the agreement with the results obtained from other techniques.

  13. Risk of DDT residue in maize consumed by infants as complementary diet in southwest Ethiopia.

    Science.gov (United States)

    Mekonen, Seblework; Lachat, Carl; Ambelu, Argaw; Steurbaut, Walter; Kolsteren, Patrick; Jacxsens, Liesbeth; Wondafrash, Mekitie; Houbraken, Michael; Spanoghe, Pieter

    2015-04-01

    Infants in Ethiopia are consuming food items such as maize as a complementary diet. However, this may expose infants to toxic contaminants like DDT. Maize samples were collected from the households visited during a consumption survey and from markets in Jimma zone, southwestern Ethiopia. The residues of total DDT and its metabolites were analyzed using the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method combined with dispersive solid phase extraction cleanup (d-SPE). Deterministic and probabilistic methods of analysis were applied to determine the consumer exposure of infants to total DDT. The results from the exposure assessment were compared with the health based guidance value in this case the provisional tolerable daily intake (PTDI). All maize samples (n=127) were contaminated by DDT, with a mean concentration of 1.770 mg/kg, which was far above the maximum residue limit (MRL). The mean and 97.5 percentile (P 97.5) estimated daily intake of total DDT for consumers were respectively 0.011 and 0.309 mg/kg bw/day for deterministic and 0.011 and 0.083 mg/kg bw/day for probabilistic exposure assessment. For total infant population (consumers and non-consumers), the 97.5 percentile estimated daily intake were 0.265 and 0.032 mg/kg bw/day from the deterministic and probabilistic exposure assessments, respectively. Health risk estimation revealed that, the mean and 97.5 percentile for consumers, and 97.5 percentile estimated daily intake of total DDT for total population were above the PTDI. Therefore, in Ethiopia, the use of maize as complementary food for infants may pose a health risk due to DDT residue. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Risk assessment for children exposed to DDT residues in various milk types from the Greek market.

    Science.gov (United States)

    Tsakiris, Ioannis N; Goumenou, Marina; Tzatzarakis, Manolis N; Alegakis, Athanasios K; Tsitsimpikou, Christina; Ozcagli, Eren; Vynias, Dionysios; Tsatsakis, Aristidis M

    2015-01-01

    The occurrence of residues of DDT and its metabolites was monitored in 196 cow milk samples of various pasteurized commercial types collected from the Greek market. Residue levels were determined by GC-MS analysis. In 97.4% of the samples at least one DDT isomer or one of the DDT metabolites was detected, in levels not exceeding the maximum permitted residue level by the EU. Hazard Index for both carcinogenic and non-carcinogenic effects was estimated under two assumptions: a) using DDT concentrations from positive samples and b) imputing LOD/2 as an arbitrary concentration for negative samples. No statistically significant differences in detected or summed residue (p > 0.05) concentrations between different milk types were observed, with the exception of specific metabolites of DDT in some milk types. Exposure assessment scenarios were developed for children aged 1, 3, 5, 7 and 12 years old based on estimated body weights and daily milk consumption. Hazard Indices for non-carcinogenic effects were below 0.109 covering also carcinogenic effects according to WHO approach. The cancer risk values for carcinogenic effects according to the US EPA Cancer Benchmark Concentration approach, ranged from 0.4 to 18. For both effects the highest values were calculated for the 1- to 3-year-old age groups. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. On the Ground or in the Air? A Methodological Experiment on Crop Residue Cover Measurement in Ethiopia.

    Science.gov (United States)

    Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash

    2017-10-01

    Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.

  16. On the Ground or in the Air? A Methodological Experiment on Crop Residue Cover Measurement in Ethiopia

    Science.gov (United States)

    Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash

    2017-10-01

    Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.

  17. RESIDUAL VALUE RISK IN AUTOMOTIVE OPERATING LEASE CONTRACTS

    Directory of Open Access Journals (Sweden)

    Ivan Tot

    2017-01-01

    Full Text Available The subject of the research in this paper are automotive operating lease contracts in the Croatian business practice. The provisions of the general terms and conditions for operating lease contracts of the Croatian leasing companies are being analysed, particulary those relating to the rights and obligations of the parties to the contract after the operating lease contract was terminated and the motor vehicle returned to the lessor. The existence of three contractual models of the automotive operating lease contract in the Croatian business practice is established, which vary with regard to the assignment and the distribution of the residual value risk. Those contractual models are being compared with the two most common contractual models of automotive lease contracts in the Austrian and German business practice: the lease contract with the excess mileage adjustment and the lease contract with the terminal rent adjustment. On the basis of the results of this comparison, applicability of the legal solutions, developed in the Austrian and German jurisprudence and legal literature regarding the lease contract with the excess mileage adjustment and the lease contract with the terminal rent adjustment, to the automotive operating lease contract within the framework of Croatian law, is being examinded.

  18. Development of risk-based computer models for deriving criteria on residual radioactivity and recycling

    International Nuclear Information System (INIS)

    Chen, S.Y.

    1994-01-01

    Argonne National Laboratory (ANL) is developing multimedia environmental pathway and health risk computer models to assess radiological risks to human health and to derive cleanup guidelines for environmental restoration, decommissioning, and recycling activities. These models are based on the existing RESRAD code, although each has a separate design and serves different objectives. Two such codes are RESRAD-BUILD and RESRAD-PROBABILISTIC. The RESRAD code was originally developed to implement the US Department of Energy's (DOE's) residual radioactive materials guidelines for contaminated soils. RESRAD has been successfully used by DOE and its contractors to assess health risks and develop cleanup criteria for several sites selected for cleanup or restoration programs. RESRAD-BUILD analyzes human health risks from radioactive releases during decommissioning or rehabilitation of contaminated buildings. Risks to workers are assessed for dismantling activities; risks to the public are assessed for occupancy. RESRAD-BUILD is based on a room compartmental model analyzing the effects on room air quality of contaminant emission and resuspension (as well as radon emanation), the external radiation pathway, and other exposure pathways. RESRAD-PROBABILISTIC, currently under development, is intended to perform uncertainty analysis for RESRAD by using the Monte Carlo approach based on the Latin-Hypercube sampling scheme. The codes being developed at ANL are tailored to meet a specific objective of human health risk assessment and require specific parameter definition and data gathering. The combined capabilities of these codes satisfy various risk assessment requirements in environmental restoration and remediation activities

  19. Development of risk-based computer models for deriving criteria on residual radioactivity and recycling

    International Nuclear Information System (INIS)

    Chen, Shih-Yew

    1995-01-01

    Argonne National Laboratory (ANL) is developing multimedia environmental pathway and health risk computer models to assess radiological risks to human health and to derive cleanup guidelines for environmental restoration, decommissioning, and recycling activities. These models are based on the existing RESRAD code, although each has a separate design and serves different objectives. Two such codes are RESRAD-BUILD and RESRAD-PROBABILISTIC. The RESRAD code was originally developed to implement the U.S. Department of Energy's (DOE's) residual radioactive materials guidelines for contaminated soils. RESRAD has been successfully used by DOE and its contractors to assess health risks and develop cleanup criteria for several sites selected for cleanup or restoration programs. RESRAD-BUILD analyzes human health risks from radioactive releases during decommissioning or rehabilitation of contaminated buildings. Risks to workers are assessed for dismantling activities; risks to the public are assessed for occupancy. RESRAD-BUILD is based on a room compartmental model analyzing the effects on room air quality of contaminant emission and resuspension (as well as radon emanation), the external radiation pathway, and other exposure pathways. RESRAD-PROBABILISTIC, currently under development, is intended to perform uncertainty analysis for RESRAD by using the Monte Carlo approach based on the Latin-Hypercube sampling scheme. The codes being developed at ANL are tailored to meet a specific objective of human health risk assessment and require specific parameter definition and data gathering. The combined capabilities of these codes satisfy various risk assessment requirements in environmental restoration and remediation activities. (author)

  20. Measuring Normative Risk Preferences

    NARCIS (Netherlands)

    G.A.G. Alserda (Gosse)

    2017-01-01

    textabstractThe results of eliciting risk preferences depend on the elicitation method. Different methods of measuring the same variable tend to produce different results. This raises the question whether normative risk preferences can be elicited at all. Using two types of manipulation, I assess

  1. Residue behavior and risk assessment of mixed formulation of imidacloprid and chlorfenapyr in chieh-qua under field conditions.

    Science.gov (United States)

    Huang, Jian Xiang; Liu, Cong Yun; Lu, Da Hai; Chen, Jia Jia; Deng, Yi Cai; Wang, Fu Hua

    2015-10-01

    A simple and rapid method based on high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed for the simultaneous determination of imidacloprid and chlorfenapyr residues in chieh-qua. Field trials were designed to investigate the dissipation and terminal residue behavior of the mixed formulation of imidacloprid and chlorfenapyr in chieh-qua in Guangzhou and Nanning areas. Risk assessment was performed by calculating the risk quotient (RQ) values. The developed analytical method exhibited recoveries of 89.9-110.3% with relative standard deviations (RSDs) of 2.8-12.5% at the spiked levels of 0.01, 0.10, and 1.00 mg/kg. The limit of detection (LOD) was 0.003 mg/kg, and the limit of quantification (LOQ) was 0.01 mg/kg for both imidacloprid and chlorfenapyr. It was found that the half-lives of imidacloprid in chieh-qua under field conditions were 3.3 and 3.5 days in Guangzhou and Nanning at a dose of 180 g ai/ha, while the half-lives of chlorfenapyr were 3.3 and 2.6 days, respectively. The terminal residues of imidacloprid and chlorfenapyr were from 0.01 to 0.21 mg/kg and from 0.01 to 0.46 mg/kg, respectively. Results of dietary exposure assessment showed that the RQ values were much lower than 1, indicating that the risk of imidacloprid and chlorfenapyr applied in chieh-qua was negligible to human health under recommended dosage and good agricultural practices. The proposed study would provide guidance for safe and reasonable use of imidacloprid and chlorfenapyr in chieh-qua cultivation in China.

  2. Legacy Risk Measure for Environmental Waste

    International Nuclear Information System (INIS)

    Eide, S. A.; Nitschke, R. L.

    2002-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) is investigating the development of a comprehensive and quantitative risk model framework for environmental management activities at the site. Included are waste management programs (high-level waste, transuranic waste, low-level waste, mixed low-level waste, spent nuclear fuel, and special nuclear materials), major environmental restoration efforts, major decontamination and decommissioning projects, and planned long-term stewardship activities. Two basic types of risk estimates are included: risks from environmental management activities, and long-term legacy risks from wastes/materials. Both types of risks are estimated using the Environment, Safety, and Health Risk Assessment Program (ESHRAP) developed at the INEEL. Given these two types of risk calculations, the following evaluations can be performed: risk evaluation of an entire program (covering waste/material as it now exists through disposal or other e nd states); risk comparisons of alternative programs or activities; comparisons of risk benefit versus risk cost for activities or entire programs; ranking of programs or activities by risk; ranking of wastes/materials by risk; evaluation of site risk changes with time as activities progress; and integrated performance measurement using indicators such as injury/death and exposure rates. This paper discusses the definition and calculation of legacy risk measures and associated issues. The legacy risk measure is needed to support three of the seven types of evaluations listed above: comparisons of risk benefit versus risk cost, ranking of wastes/materials by risk, and evaluation of site risk changes with time

  3. Diffraction grating strain gauge method: error analysis and its application for the residual stress measurement in thermal barrier coatings

    Science.gov (United States)

    Yin, Yuanjie; Fan, Bozhao; He, Wei; Dai, Xianglu; Guo, Baoqiao; Xie, Huimin

    2018-03-01

    Diffraction grating strain gauge (DGSG) is an optical strain measurement method. Based on this method, a six-spot diffraction grating strain gauge (S-DGSG) system has been developed with the advantages of high and adjustable sensitivity, compact structure, and non-contact measurement. In this study, this system is applied for the residual stress measurement in thermal barrier coatings (TBCs) combining the hole-drilling method. During the experiment, the specimen’s location is supposed to be reset accurately before and after the hole-drilling, however, it is found that the rigid body displacements from the resetting process could seriously influence the measurement accuracy. In order to understand and eliminate the effects from the rigid body displacements, such as the three-dimensional (3D) rotations and the out-of-plane displacement of the grating, the measurement error of this system is systematically analyzed, and an optimized method is proposed. Moreover, a numerical experiment and a verified tensile test are conducted, and the results verify the applicability of this optimized method successfully. Finally, combining this optimized method, a residual stress measurement experiment is conducted, and the results show that this method can be applied to measure the residual stress in TBCs.

  4. Effect of pyrolysis temperature on chemical form, behavior and environmental risk of Zn, Pb and Cd in biochar produced from phytoremediation residue.

    Science.gov (United States)

    Huang, Hui; Yao, Wenlin; Li, Ronghua; Ali, Amjad; Du, Juan; Guo, Di; Xiao, Ran; Guo, Zhanyu; Zhang, Zengqiang; Awasthi, Mukesh Kumar

    2018-02-01

    This study aimed to evaluate the chemical forms, behavior and environmental risk of heavy metal (HMs) Zn, Pb and Cd in phytoremediation residue (PMR) pyrolyzed at 350 °C, 550 °C and 750 °C, respectively. The behavior of HMs variation during the PMR pyrolysis process was analyzed and the potential HMs environmental risk of phytoremediation residue biochars (PMB) was assessed which was seldom investigated before. The results showed that the pyrolysis temperature increase decreased the soluble/exchangeable HMs fraction and alleviated the HMs bioavailability. When the temperature was over 550 °C, the adsorbed Zn(II), Pb(II) and Cd(II) were turned into oxides forms and concentrated in PMB with more stable forms exhibiting lower risk assessment code and potential ecological risk index. The ecotoxicity test showed higher pyrolysis temperature favored the reduction of PMB ecotoxicity. It is suggested that pyrolysis temperature above 550°C may be suitable for thermal treatment of PMR with acceptable environmental risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Discussion on accuracy of weld residual stress measurement by neutron diffraction. Influence of strain free reference

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Akita, Koichi

    2012-01-01

    It is required to evaluate a strain-free reference, α 0 , to perform accurate stress measurement using neutron diffraction. In this study, accuracy of neutron stress measurement was quantitatively discussed from α 0 evaluations on a dissimilar metal butt-weld between a type 304 austenitic stainless steel and an A533B low alloy ferritic steel. A strain-free standard specimen and a sliced specimen with 10 mm thickness taken from the dissimilar metal butt-weld were utilized. In the lattice constant evaluation using the standard specimen, average lattice constant derived from multiple hkl reflections was evaluated as the stress-free reference with cancelling out an intergranular strain. Comparing lattice constant distributions in each reflection with average lattice constant distribution in the standard specimen, αFe211 and γFe311 reflections were judged as a suitable reflection for neutron strain measurement to reduce intergranular strain effects. Residual stress distribution in the sliced specimen evaluated using α 0 measured here exhibited higher accuracy than that measured using strain gauges. On the other hand, α 0 distributions were evaluated using the sliced specimen under the plane-stress condition. Existence of slight longitudinal residual stresses near the weld center decreased accuracy of the α 0 evaluations, which means that it is required to optimize the thickness of the sliced specimen for accurate α 0 evaluation under plane strain condition. As a conclusion of this study, it was confirmed that procedures of accurate α 0 evaluation, optimization of the measurement condition, and multiple evaluations on the results play an important role to improve accuracy of the residual stress measurement using neutron diffraction. (author)

  6. Decision principles derived from risk measures

    NARCIS (Netherlands)

    Goovaerts, M.J.; Kaas, R.; Laeven, R.J.A.

    2010-01-01

    In this paper, we argue that a distinction exists between risk measures and decision principles. Though both are functionals assigning a real number to a random variable, we think there is a hierarchy between the two concepts. Risk measures operate on the first "level", quantifying the risk in the

  7. A flexible method for residual stress measurement of spray coated layers by laser made hole drilling and SLM based beam steering

    Science.gov (United States)

    Osten, W.; Pedrini, G.; Weidmann, P.; Gadow, R.

    2015-08-01

    A minimum invasive but high resolution method for residual stress analysis of ceramic coatings made by thermal spraycoating using a pulsed laser for flexible hole drilling is described. The residual stresses are retrieved by applying the measured surface data for a model-based reconstruction procedure. While the 3D deformations and the profile of the machined area are measured with digital holography, the residual stresses are calculated by FE analysis. To improve the sensitivity of the method, a SLM is applied to control the distribution and the shape of the holes. The paper presents the complete measurement and reconstruction procedure and discusses the advantages and challenges of the new technology.

  8. Determination of the Ability to Measure Traces of Water in Dehydrated Residues of Waste Water by IR Diffuse Reflectance Spectra

    Science.gov (United States)

    Pratsenka, S. V.; Voropai, E. S.; Belkin, V. G.

    2018-01-01

    Rapid measurement of the moisture content of dehydrated residues is a critical problem, the solution of which will increase the efficiency of treatment facilities and optimize the process of applying flocculants. The ability to determine the moisture content of dehydrated residues using a meter operating on the IR reflectance principle was confirmed experimentally. The most suitable interference filters were selected based on an analysis of the obtained diffuse reflectance spectrum of the dehydrated residue in the range 1.0-2.7 μm. Calibration curves were constructed and compared for each filter set. A measuring filter with a transmittance maximum at 1.19 μm and a reference filter with a maximum at 1.3 μm gave the best agreement with the laboratory measurements.

  9. Unnoticed Post-Void Residual Urine Volume in People with Moderate to Severe Intellectual Disabilities: Prevalence and Risk Factors

    Science.gov (United States)

    de Waal, K. H.; Tinselboer, B. M.; Evenhuis, H. M.; Penning, C.

    2009-01-01

    Background: Increased post-void residual urine volume (PVR) is often seen in geriatric populations. People with intellectual disabilities (ID) have risk factors in common with these populations. Aims: To investigate in adults with ID: (1) Feasibility of portable ultrasound bladder scanning; (2) Prevalence of PVR; and (3) Relations with proposed…

  10. Numerical analysis of drilling hole work-hardening effects in hole-drilling residual stress measurement

    Science.gov (United States)

    Li, H.; Liu, Y. H.

    2008-11-01

    The hole-drilling strain gage method is an effective semi-destructive technique for determining residual stresses in the component. As a mechanical technique, a work-hardening layer will be formed on the surface of the hole after drilling, and affect the strain relaxation. By increasing Young's modulus of the material near the hole, the work-hardening layer is simplified as a heterogeneous annulus. As an example, two finite rectangular plates submitted to different initial stresses are treated, and the relieved strains are measured by finite element simulation. The accuracy of the measurement is estimated by comparing the simulated residual stresses with the given initial ones. The results are shown for various hardness of work-hardening layer. The influence of the relative position of the gages compared with the thickness of the work-hardening layer, and the effect of the ratio of hole diameter to work-hardening layer thickness are analyzed as well.

  11. Measures of risk importance and their applications

    International Nuclear Information System (INIS)

    Vesely, W.E.; Davis, T.C.; Denning, R.S.; Saltos, N.

    1983-07-01

    This work is part of a project being conducted for the Division of Risk Analysis (DRA) of the Nuclear Regulatory Commission (NRC). The objectives of the project are to evaluate the importances of containment, the different safety functions, and other various contributers as assessed in probabilistic risk analyses and to identify generic conclusions regarding the importances. Effective display of the importances is an important part of these objectives. To address these objectives, measures of risk importance need to be first identified and then they need to be evaluated for the different risk analyses which have been performed. This report describes the risk importance measures that were defined and were applied to the risk analyses which were performed as part of the Reactor Safety Study Methodology Applications Program (RSSMAP). The risk importance measures defined in this report measure the importance of features not only with regard to risk reduction but also with regard to reliability assurance, or risk maintenance. The goal of this report is not to identify new mathematical formulas for risk importance but to show how importance measures can be interpreted and can be applied

  12. Relation between psi-splitting and microscopic residual shear stresses in x-ray stress measurement on uni-directionally deformed layers

    International Nuclear Information System (INIS)

    Hanabusa, Takao; Fujiwara, Haruo

    1982-01-01

    The psi-splitting behaviors were investigated for the ground and the milled surface layers of both iron and high speed steel in order to find out the relation among microscopic residual shear stresses. For the high speed steel, the X-ray elastic constants and the residual strains were measured on the carbide phase as well as on the matrix phase. It was clarified that the psi-splitting was caused by a combination of the selective nature of X-ray diffractions and the microscopic residual shear stresses within the interior of cells and the carbide particles. The volume fraction occupied by the cell walls and the residual shear stresses sustained by them were estimated from the equilibrium condition of the microscopic residual shear stresses. The distributions of residual stresses over the deformed layers indicate that the thermal effect is dominant in grinding and the mechanical effect is dominant in milling for forming residual stresses. (author)

  13. DEPENDENCIES TO DETERMINE THE MEASURE OF DAMAGE AND CALCULATION OF RESIDUAL LIFE OF REINFORCED CONCRETE SUPERSTRUCTURE, EXPOSED TO SALT CORROSION

    OpenAIRE

    SAATOVA NODIRA ZIYAYEVNA

    2016-01-01

    In this paper we consider the current method of determining the measure of damage of concrete and reinforcement. The proposed dependence measures of damage, convenient for use in predicting the life of structures superstructures.The practical method of calculation determination of residual resource of the exploited superstructures developed. The main source of data for calculating the residual life are the parameters defined by the technical diagnosis.

  14. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan

    2013-08-31

    We present the results of the assessment of the intramolecular residue-residue contact predictions from 26 prediction groups participating in the 10th round of the CASP experiment. The most recently developed direct coupling analysis methods did not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i.e., prediction accuracy and the difference between the distribution of the predicted contacts and that of all pairs of residues in the target protein), as well as new measures, such as the Matthews correlation coefficient, the area under the precision-recall curve and the ranks of the first correctly and incorrectly predicted contact. We also evaluated the ability to detect interdomain contacts and tested whether the difficulty of predicting contacts depends upon the protein length and the depth of the family sequence alignment. The analyses were carried out on the target domains for which structural homologs did not exist or were difficult to identify. The evaluation was performed for all types of contacts (short, medium, and long-range), with emphasis placed on long-range contacts, i.e. those involving residues separated by at least 24 residues along the sequence. The assessment suggests that the best CASP10 contact prediction methods perform at approximately the same level, and comparably to those participating in CASP9.

  15. Residual stresses in cold-coiled helical compression springs for automotive suspensions measured by neutron diffraction

    Czech Academy of Sciences Publication Activity Database

    Matějíček, Jiří; Brand, P. C.; Drews, A. R.; Krause, A.; Lowe-Ma, C.

    2004-01-01

    Roč. 367, 1-2 (2004), s. 306-311 ISSN 0921-5093 Institutional research plan: CEZ:AV0Z2043910 Keywords : residual stress, automotive springs, neutron diffraction Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.445, year: 2004

  16. Molecular sources of residual cardiovascular risk, clinical signals, and innovative solutions: relationship with subclinical disease, undertreatment, and poor adherence: implications of new evidence upon optimizing cardiovascular patient outcomes

    Directory of Open Access Journals (Sweden)

    Kones R

    2013-10-01

    the conditional pleiotropic actions of HDL. Non-HDL cholesterol reflects the cholesterol in all atherogenic particles containing apolipoprotein B, and has outperformed LDL cholesterol as a lipid marker of cardiovascular risk and future mortality. In addition to including a measure of residual risk, the advantages of using non-HDL cholesterol as a primary lipid target are now compelling. Reinterpretation of data from the Treating to New Targets study suggests that better control of smoking, body weight, hypertension, and diabetes will help lower residual risk. Although much improved, control of risk factors other than LDL cholesterol currently remains inadequate due to shortfalls in compliance with guidelines and poor patient adherence. More efficient and greater use of proven simple therapies, such as aspirin, beta-blockers, angiotensin-converting enzyme inhibitors and angiotensin II receptor blockers, combined with statin therapy, may be more fruitful in improving outcomes than using other complex therapies. Comprehensive, intensive, multimechanistic, global, and national programs using primordial, primary, and secondary prevention to lower the total level of cardiovascular risk are necessary.Keywords: cardiovascular prevention, low-density lipoprotein, high-density lipoprotein, statin drugs, metabolic syndrome, obesity, diabetes, niacin, AIM-HIGH study, cholesteryl ester transfer protein, endothelial progenitor cells, fibrate drugs

  17. Development of nondestructive hybrid measuring method for three-dimensional residual stress distribution of thick welded joint. Hybrid measuring method of inherent strain method and neutron diffraction method

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Kasahara, Norifumi; Tamura, Ryota

    2012-01-01

    The measuring methods of the residual stress are classified into destructive one and nondestructive one. The inherent strain method (ISM) is destructive one. The neutron diffraction method (NDM) is nondestructive one. But the measurable depth is limited within about 20 mm and the method cannot measure the weld zone, without destruction of the object. So, in this study, the hybrid measuring method has been developed, by combining the ISM and the NDM. The theory of the hybrid method is the same as the ISM. In the analysis, the strains measured by the NDM without destruction are used. This hybrid measuring method is a true nondestructive measuring method for a thick welded joint. The applicability of the hybrid method has been verified by simulation, using a butt welded joint of thick pipes. In the simulation, the reliable order of the strains measured by the present NDM is very important, and was considered as 10 micro. The measurable regions by the present NDM were assumed. Under the above conditions, the data (the residual elastic strains assumed to be measured by the NDM) were made, and used in the ISM. As a result of such simulation, it has been cleared that the estimated residual stress has very high accuracy, if enough data are used. The required number of data is less than the ISM. (author)

  18. Dissipation behaviour, residue distribution and dietary risk assessment of tetraconazole and kresoxim-methyl in greenhouse strawberry via RRLC-QqQ-MS/MS technique.

    Science.gov (United States)

    Chen, Xiaoxin; Fan, Xueqi; Ma, Yecheng; Hu, Jiye

    2018-02-01

    20% commercial suspension emulsion (SE) of (8% tetraconazole + 12% kresoxim-methyl), as a pre-registered product in China, was firstly investigated under Chinese greenhouse-field conditions. A MWCNTs-based QuEChERS method for simultaneous determination of tetraconazole and kresoxim-methyl in strawberry was developed and validated via RRLC-QqQ-MS/MS. On basis of this method, the dissipation behaviours, residue distributions and dietary risk probability of these fungicides in strawberry were further investigated for food safety. The dissipations of tetraconazole and kresoxim-methyl followed first-order kinetics with the half-lives of 8.0-18.2 days. The highest residues (HRs) of these fungicides in the supervised trials at the pre-harvest interval (PHI, 3 days) were below 0.8970mgkg -1 . The total national estimated daily intake (NEDI) of tetraconazole and kresoxim-methy in strawberry at the PHI 3day was 0.2784mg and 0.4031mg, respectively, based on Chinese dietary pattern and terminal residue distributions under good agricultural practices (GAP) conditions. The risk quotients (RQs) of tetraconazole and kresoxim-methy at PHI 3 days were below 82.7% and 1.6%, respectively, showing that the evaluated strawberry exhibited an acceptably low dietary risk to consumers. The current study could not only guide reasonable usage of the formulation, but also facilitate the setting of maximum residue limits (MRLs) of tetraconazole in strawberry. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Entropy coherent and entropy convex measures of risk

    NARCIS (Netherlands)

    Laeven, R.J.A.; Stadje, M.

    2013-01-01

    We introduce two subclasses of convex measures of risk, referred to as entropy coherent and entropy convex measures of risk. Entropy coherent and entropy convex measures of risk are special cases of φ-coherent and φ-convex measures of risk. Contrary to the classical use of coherent and convex

  20. Measurements of the residual stresses in the welded steel columns based on the x-ray diffraction method, 2

    International Nuclear Information System (INIS)

    Kaneta, Kiyoshi; Nishizawa, Hidekazu; Arashiyama, Masaki.

    1982-01-01

    In order to evaluate the applicability of two kinds of techniques of the X-ray stress analysis, namely, the standard sin 2 psi method and the newly developed phi-sin 2 psi method, bending tests have been performed. The test results have proved that the values of the stresses measured by means of the mechanical devices and of those measured by the two kinds of the X-ray techniques coincide each other. Then, these two methods have been applied to measure the surface residual stresses of the box-typed, welded steel columns and the following conclusions have been drawn. 1. The principal stress of the surface residural stresses is, in most cases, oriented to the rolled directions at the center of the steel plates, and it tends to rotate in the neighborhood of the heat affected zones. 2. Tensile residual stresses of a large magnitude have been observed in the direction parallel to the beads of the weld, and the moderate compressive residual stresses can be detected in the direction normal to the beads. (author)

  1. Residual Resistivity Ratio (RRR) Measurements of LHC Superconducting NbTi Cable Strands

    CERN Document Server

    Charifoulline, Z

    2006-01-01

    The Rutherford-type superconducting NbTi cables of the LHC accelerator are currently manufactured by six industrial companies. As a part of the acceptance tests, the Residual Resistivity Ratio (RRR) of superconducting strands is systematically measured on virgin strands to qualify the strands before cabling and on extracted strands to qualify the cables and to check the final heat treatment (controlled oxidation to control interstrand resistance). More than 12000 samples of virgin and extracted strands have been measured during last five years. Results show good correlation with the measurements done by the companies and reflect well the technological process of cable production (strand annealing, cabling, cable heat treatment). This paper presents a description of the RRR-test station and the measurement procedure, the summary of the results over all suppliers and finally the correlation between RRR-values of the cables and the magnets.

  2. A comparison of conventional and prototype nondestructive measurements on molten salt extraction residues

    International Nuclear Information System (INIS)

    Longmire, V.L.; Scarborough, A.M.

    1987-01-01

    Impure plutonium metal is routinely processed by molten salt extraction (MSE) to reduce the amount of americium in the metal product. Individuals form four technical groups at the Los Alamos National Laboratory (LANL) participated in a study designed to evaluate the accuracy of various nondestructive assay (NDA) techniques for measuring the plutonium content in MSE residues. This study was performed to improve in-house accountability of these items and to identify assay methods that would be acceptable for determining receiver's values for MSE salts from off-site sources. Recent upgrades have been made in a segmented gamma scan system, in a thermal neutron coincidence counter, and in the software of a gamma isotopic system that supports the calorimeters at LAPF. The authors evaluated the newer systems against the older systems versus destructive qualitative analyses. Fourteen containers of MSE residues were selected to be studied. Seven of these salts originated at LAPF and seven originated at Rockwell International Rocky Flats plant. Measurements have been performed on these items in their original containers, and the items have been repackaged into a different geometry and assayed again

  3. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution's leverage and with its expected loss in the tail of the system's loss distribution. Institutions internalize their externality if they are ‘taxed’ based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  4. R6 validation exercise: through thickness residual stress measurements on an experiment test vessel ring

    International Nuclear Information System (INIS)

    Mitchell, D.H.

    1988-06-01

    A series of bursting tests on thick-walled pressure vessels has been carried out as part of a validation exercise for the CEGB R6 failure assessment procedure. The objective of these tests was the examination of the behaviour of typical PWR primary vessel material subject to residual stresses in addition to primary loading with particular reference to the R6 assessment procedure. To this end, a semi-elliptic part-through defect was sited in the vessel longitudinal seam, which was a submerged arc weld in the non stress-relieved condition; it was then pressure tested to failure. Prior to the final assembly of this vessel, a ring of material was cut from it to act as a test-piece on which a residual stress survey could be made. Surface measurements using the centre-hole technique were made by CERL personnel, and this has been followed by two through- thickness measurements at BNL using the deep-hole technique. This paper describes these deep-hole measurements and presents the results from them. (author)

  5. Residual neuromuscular block as a risk factor for critical respiratory events in the post anesthesia care unit.

    Science.gov (United States)

    Norton, M; Xará, D; Parente, D; Barbosa, M; Abelha, F J

    2013-04-01

    Residual neuromuscular block is an important postoperative complication associated to the use of neuromuscular blocking drugs. The purpose of this study was to access the incidence of residual neuromuscular block in a post-anesthesia care unit and to evaluate its association with critical respiratory events. Prospective cohort study was conducted in a Post Anesthetic Care Unit (PACU) for a period of 3 weeks. Two hundred two adult patients who submitted to scheduled non-cardiac and non-intracranial surgery were eligible to the study. The primary outcome variable was residual neuromuscular block after arrival to PACU that was defined as train-of-four ratio <0.9 and objectively quantified using acceleromyography. Demographic data, perioperative variables, lengths of hospital and recovery room stay and critical respiratory events were recorded. Inadequate emergence was classified in its different forms according to the Richmond agitation and sedation scale 10 min after admission to the recovery room. Residual neuromuscular block incidence in the post-anesthesia care unit was 29.7% (95% confidence interval: 23.4, 36.1). Patients with residual neuromuscular block had more frequently overall critical respiratory events (51% versus 16%, P<0.001), airway obstruction (10% versus 2%, P=0.029), mild-moderate hypoxemia (23% versus 4%, P<0.001), severe hypoxemia (7% versus 1%, P=0.033), respiratory failure (8% versus 1%, P=0.031), inability to breathe deeply (38% versus 12%, P<0.001) and muscular weakness (16% versus 1%, P<0.001). Residual neuromuscular block was more common after high-risk surgery (53% versus 33%, P=0.011) and was more often associated with post-operative hypoactive emergence as defined by the Richmond Agitation and Sedation Scale (21% versus 6%, P=0.001). This study suggests that residual neuromuscular block is common in the PACU and is associated with more frequent critical respiratory events. Copyright © 2012 Sociedad Española de Anestesiología, Reanimaci

  6. 40 CFR 158.1410 - Residue chemistry data requirements table.

    Science.gov (United States)

    2010-07-01

    ... table. 158.1410 Section 158.1410 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... example, most products used in or near kitchens require residue data for risk assessment purposes even... NR PAIRA 7 Analytical methods 860.1340 Residue analytical methods R R R CR CR Residue of concern 1, 3...

  7. Single particle measurements of the chemical composition of cirrus ice residue during CRYSTAL-FACE

    Science.gov (United States)

    Cziczo, D. J.; Murphy, D. M.; Hudson, P. K.; Thomson, D. S.

    2004-02-01

    The first real-time, in situ, investigation of the chemical composition of the residue of cirrus ice crystals was performed during July 2002. This study was undertaken on a NASA WB-57F high-altitude research aircraft as part of CRYSTAL-FACE, a field campaign which sought to further our understanding of the relation of clouds, water vapor, and climate by characterizing, among other parameters, anvil cirrus formed about the Florida peninsula. A counter flow virtual impactor (CVI) was used to separate cirrus ice from the unactivated interstitial aerosol particles and evaporate condensed-phase water. Residual material, on a crystal-by-crystal basis, was subsequently analyzed using the NOAA Aeronomy Laboratory's Particle Analysis by Laser Mass Spectrometry (PALMS) instrument. Sampling was performed from 5 to 15 km altitude and from 12° to 28° north latitude within cirrus originating over land and ocean. Chemical composition measurements provided several important results. Sea salt was often incorporated into cirrus, consistent with homogeneous ice formation by aerosol particles from the marine boundary layer. Size measurements showed that large particles preferentially froze over smaller ones. Meteoritic material was found within ice crystals, indicative of a relation between stratospheric aerosol particles and tropospheric clouds. Mineral dust was the dominant residue observed in clouds formed during a dust transport event from the Sahara, consistent with a heterogeneous freezing mechanism. These results show that chemical composition and size are important determinants of which aerosol particles form cirrus ice crystals.

  8. Residual stress measurements in the dissimilar metal weld in pressurizer safety nozzle of nuclear power plant

    International Nuclear Information System (INIS)

    Campos, Wagner R.C.; Rabello, Emerson G.; Mansur, Tanius R.; Scaldaferri, Denis H.B.; Paula, Raphael G.; Souto, Joao P.R.S.; Carvalho Junior, Ideir T.

    2013-01-01

    Weld residual stresses have a large influence on the behavior of cracking that could possibly occur under normal operation of components. In case of an unfavorable environment, both stainless steel and nickel-based weld materials can be susceptible to stress-corrosion cracking (SCC). Stress corrosion cracks were found in dissimilar metal welds of some pressurized water reactor (PWR) nuclear plants. In the nuclear reactor primary circuit the presence of tensile residual stress and corrosive environment leads to so-called Primary Water Stress Corrosion Cracking (PWSCC). The PWSCC is a major safety concern in the nuclear power industry worldwide. PWSCC usually occurs on the inner surface of weld regions which come into contact with pressurized high temperature water coolant. However, it is very difficult to measure the residual stress on the inner surfaces of pipes or nozzles because of inaccessibility. A mock-up of weld parts of a pressurizer safety nozzle was fabricated. The mock-up was composed of three parts: an ASTM A508 C13 nozzle, an ASTM A276 F316L stainless steel safe-end, an AISI 316L stainless steel pipe and different filler metals of nickel alloy 82/182 and AISI 316L. This work presents the results of measurements of residual strain from the outer surface of the mock-up welded in base metals and filler metals by hole-drilling strain-gage method of stress relaxation. (author)

  9. CONTINGENCIES FOR MEASUREMENT OF THE CREDIT RISK

    Directory of Open Access Journals (Sweden)

    Marinela BARBULESCU

    2015-12-01

    Full Text Available The Global Financial Crisis, which affected various banks, some of them very important banks, highlighted the importance of an accurate credit risk measurement in order to be able to overcome it. There are a variety of such credit risk measurement models, so we can say that banks face a real dilemma when having to choose the most appropriate one. The aim of this paper is to examine the most popular methods used to measure the credit risk and to identify the strengths and the weaknesses of each one of it. The research was accomplished from a double perspective, in which the conceptual methodological approach is correlated to a variety of references to practical actions aiming the measurement and the prevention of credit risk. The study includes the presentation of the objectives of credit risk analysis, the most appropriate moments for doing such an analysis, the steps that have to be done in order to measure the credit risk, the errors that can overcome in the credit risk measurement system, generated by the misclassifications of the studied company, and the presentation of the specific information of financial creditors. The findings expressed in this paper were mainly the result of a qualitative analysis which showed that there is no best model for credit risk measurement, each one having both strengths and weaknesses, some providing a comprehensive analysis of the individual customer’s financial strength others allowing banks permanently monitor fluctuating default risk and identify the possibly problems at an early stage.

  10. Erika: evaluation of residual sanitary risks linked to the beaches-going after cleaning-up; Erika: evaluation des risques sanitaires residuels lies a la frequentation des plages apres depollution

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The aim of this study is to evaluate the sanitary risks for the populations frequenting the coast beaches affected by the fuel oils of the tanker Erika, after their cleaning up. This quantitative evaluation of sanitary risks is led according to a protocol developed jointly between the two institutes ( the national institute of industrial environment and risks, I.N.E.R.I.S., and the national institute of sanitary watch I.n.V.S.). It does not give the risks in function the residual pollution level of concerned beaches but supplies to the authorities elements of scientific information in order to allow them to choose criteria appropriate for the management of eventual residual risks. (N.C.)

  11. Developing risk management dashboards using risk and quality measures: A visual best practices approach.

    Science.gov (United States)

    Bunting, Robert F; Siegal, Dana

    2017-10-01

    Because quality measures are ubiquitous, health care risk management leaders often use them as a proxy for risk management measures. While certain quality measures adequately reflect some aspects of risk management, they are neither a perfect nor complete substitute for well-developed and comprehensive risk management measures. Using a comprehensive approach consisting of quality measures, risk measures, and measures that are less amenable to classification would be the best approach. Identifying the most powerful and informative measures, designing the most appropriate dashboards, and incorporating visual best practices are crucial steps required for evaluating the effectiveness and value of an enterprise risk management program. The authors explain the terms and concepts, review the measures available in the literature, propose new measures, discuss visual best practices, and provide sample dashboard components. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.

  12. Application of different measures of bioavailability to support the derivation of risk-based remedial benchmarks for PHC-contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, G. [Stantec Consulting Ltd., Surrey, BC (Canada)

    2009-07-01

    Risk estimates and exposure scenarios hardly ever take into consideration site-specific bioavailability of contaminants. Risk assessors frequently adopt the assumption that a contaminant in soils is 100 percent bioavailable, resulting in an overestimation of the risks associated with contamination. Remedial targets or benchmarks derived in light of this assumption are needlessly low and might be technically unattainable or prohibitive in terms of cost. This presentation discussed a research project whose goal was to develop a tool kit to measure or determine site-specific bioavailability of contaminants (PHCs) in soils to ecological receptors. Tools that were discussed included: biological measures such as toxicity tests, contaminant residues in tissues, and bioaccumulation tests. Chemical measures such as bioaccessibility tests and other biomimetic devices (SPMDs), biotic ligand modeling, and chemical extractions were also presented. Preliminary investigation results were provided. Other topics that were discussed included: single-species toxicity tests; preliminary comparisons; the site; bioaccumulation; and toxicity to earthworms. It was concluded that total soil and water-extractable concentrations did not correlate well with toxicity. tabs., figs.

  13. FEM Analysis and Measurement of Residual Stress by Neutron Diffraction on the Dissimilar Overlay Weld Pipe

    International Nuclear Information System (INIS)

    Kim, Kang Soo; Lee, Ho Jin; Woo, Wan Chuck; Seong, Baek Seok; Byeon, Jin Gwi; Park, Kwang Soo; Jung, In Chul

    2010-01-01

    Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-ray method and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic Energy Research Institute). Secondly, FEM Model on the dissimilar overlay weld pipe was made and analyzed by the ABAQUS Code (ABAQUS, 2004). Thermal analysis and stress analysis were performed, and the residual stress was calculated. Thirdly, the results of the FEM analysis were compared with those of the experimental methods

  14. Improved structural integrity through advances in reliable residual stress measurement: the impact of ENGIN-X

    Science.gov (United States)

    Edwards, L.; Santisteban, J. R.

    The determination of accurate reliable residual stresses is critical to many fields of structural integrity. Neutron stress measurement is a non-destructive technique that uniquely provides insights into stress fields deep within engineering components and structures. As such, it has become an increasingly important tool within engineering, leading to improved manufacturing processes to reduce stress and distortion as well as to the definition of more precise lifing procedures. This paper describes the likely impact of the next generation of dedicated engineering stress diffractometers currently being constructed and the utility of the technique using examples of residual stresses both beneficial and detrimental to structural integrity.

  15. Risk Metrics and Measures for an Extended PSA

    International Nuclear Information System (INIS)

    Wielenberg, A.; Loeffler, H.; Hasnaoui, C.; Burgazzi, L.; Cazzoli, E.; Jan, P.; La Rovere, S.; Siklossy, T.; Vitazkova, J.; Raimond, E.

    2016-01-01

    This report provides a review of the main used risk measures for Level 1 and Level 2 PSA. It depicts their advantages, limitations and disadvantages and develops some more precise risk measures relevant for extended PSAs and helpful for decision-making. This report does not recommend or suggest any quantitative value for the risk measures. It does not discuss in details decision-making based on PSA results neither. The choice of one appropriate risk measure or a set of risk measures depends on the decision making approach as well as on the issue to be decided. The general approach for decision making aims at a multi-attribute approach. This can include the use of several risk measures as appropriate. Section 5 provides some recommendations on the main risk metrics to be used for an extended PSA. For Level 1 PSA, Fuel Damage Frequency and Radionuclide Mobilization Frequency are recommended. For Level 2 PSA, the characterization of loss of containment function and a total risk measure based on the aggregated activity releases of all sequences rated by their frequencies is proposed. (authors)

  16. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  17. Synchrotron X-ray measurement of residual strain within the nose of a worn manganese steel railway crossing

    Science.gov (United States)

    Dhar, S.; Zhang, Y.; Xu, R.; Danielsen, HK; Jensen, D. Juul

    2017-07-01

    Switches and crossings are an integral part of any railway network. Plastic deformation associated with wear and rolling contact fatigue due to repeated passage of trains cause severe damage leading to the formation of surface and sub-surface cracks which ultimately may result in rail failure. Knowledge of the internal stress distribution adds to the understanding of crack propagation and may thus help to prevent catastrophic rail failures. In this work, the residual strains inside the bulk of a damaged nose of a manganese railway crossing that was in service for five years has been investigated by using differential aperture synchrotron X-ray diffraction. The main purpose of this paper is to describe how this method allows non-destructive measurement of residual strains in selected local volumes in the bulk of the rail. Measurements were conducted on the transverse surface at a position about 6.5 mm from the rail running surface of a crossing nose. The results revealed the presence of significant compressive residual strains along the running direction of the rail.

  18. Tychastic measure of viability risk

    CERN Document Server

    Aubin, Jean-Pierre; Dordan, Olivier

    2014-01-01

    This book presents a forecasting mechanism of the price intervals for deriving the SCR (solvency capital requirement) eradicating the risk during the exercise period on one hand, and measuring the risk by computing the hedging exit time function associating with smaller investments the date until which the value of the portfolio hedges the liabilities on the other. This information, summarized under the term “tychastic viability measure of risk” is an evolutionary alternative to statistical measures, when dealing with evolutions under uncertainty. The book is written by experts in the field and the target audience primarily comprises research experts and practitioners.

  19. Depleted uranium residual radiological risk assessment for Kosovo sites

    International Nuclear Information System (INIS)

    Durante, Marco; Pugliese, Mariagabriella

    2003-01-01

    During the recent conflict in Yugoslavia, depleted uranium rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of areas in Kosovo with depleted uranium penetrators and dust. Although chemical toxicity is the most significant health risk related to uranium, radiation exposure has been allegedly related to cancers among veterans of the Balkan conflict. Uranium munitions are considered to be a source of radiological contamination of the environment. Based on measurements and estimates from the recent Balkan Task Force UNEP mission in Kosovo, we have estimated effective doses to resident populations using a well-established food-web mathematical model (RESRAD code). The UNEP mission did not find any evidence of widespread contamination in Kosovo. Rather than the actual measurements, we elected to use a desk assessment scenario (Reference Case) proposed by the UNEP group as the source term for computer simulations. Specific applications to two Kosovo sites (Planeja village and Vranovac hill) are described. Results of the simulations suggest that radiation doses from water-independent pathways are negligible (annual doses below 30 μSv). A small radiological risk is expected from contamination of the groundwater in conditions of effective leaching and low distribution coefficient of uranium metal. Under the assumptions of the Reference Case, significant radiological doses (>1 mSv/year) might be achieved after many years from the conflict through water-dependent pathways. Even in this worst-case scenario, DU radiological risk would be far overshadowed by its chemical toxicity

  20. A neural measure of behavioral engagement: task-residual low-frequency blood oxygenation level-dependent activity in the precuneus.

    Science.gov (United States)

    Zhang, Sheng; Li, Chiang-Shan Ray

    2010-01-15

    Brain imaging has provided a useful tool to examine the neural processes underlying human cognition. A critical question is whether and how task engagement influences the observed regional brain activations. Here we highlighted this issue and derived a neural measure of task engagement from the task-residual low-frequency blood oxygenation level-dependent (BOLD) activity in the precuneus. Using independent component analysis, we identified brain regions in the default circuit - including the precuneus and medial prefrontal cortex (mPFC) - showing greater activation during resting as compared to task residuals in 33 individuals. Time series correlations with the posterior cingulate cortex as the seed region showed that connectivity with the precuneus was significantly stronger during resting as compared to task residuals. We hypothesized that if the task-residual BOLD activity in the precuneus reflects engagement, it should account for a certain amount of variance in task-related regional brain activation. In an additional experiment of 59 individuals performing a stop signal task, we observed that the fractional amplitude of low-frequency fluctuation (fALFF) of the precuneus but not the mPFC accounted for approximately 10% of the variance in prefrontal activation related to attentional monitoring and response inhibition. Taken together, these results suggest that task-residual fALFF in the precuneus may be a potential indicator of task engagement. This measurement may serve as a useful covariate in identifying motivation-independent neural processes that underlie the pathogenesis of a psychiatric or neurological condition.

  1. Quantitative Measures of Mineral Supply Risk

    Science.gov (United States)

    Long, K. R.

    2009-12-01

    Almost all metals and many non-metallic minerals are traded internationally. An advantage of global mineral markets is that minerals can be obtained from the globally lowest-cost source. For example, one rare-earth element (REE) mine in China, Bayan Obo, is able to supply most of world demand for rare earth elements at a cost significantly less than its main competitors. Concentration of global supplies at a single mine raises significant political risks, illustrated by China’s recent decision to prohibit the export of some REEs and severely limit the export of others. The expected loss of REE supplies will have a significant impact on the cost and production of important national defense technologies and on alternative energy programs. Hybrid vehicles and wind-turbine generators, for example, require REEs for magnets and batteries. Compact fluorescent light bulbs use REE-based phosphors. These recent events raise the general issue of how to measure the degree of supply risk for internationally sourced minerals. Two factors, concentration of supply and political risk, must first be addressed. Concentration of supply can be measured with standard economic tools for measuring industry concentration, using countries rather than firms as the unit of analysis. There are many measures of political risk available. That of the OECD is a measure of a country’s commitment to rule-of-law and enforcement of contracts, as well as political stability. Combining these measures provides a comparative view of mineral supply risk across commodities and identifies several minerals other than REEs that could suddenly become less available. Combined with an assessment of the impact of a reduction in supply, decision makers can use these measures to prioritize risk reduction efforts.

  2. Residual risks of the 13{sup th} amendment to the German Atomic Energy Act; Restrisiken der 13. Atomgesetzaenderung

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Horst

    2011-08-15

    The 13th amendment to the German Atomic Energy Act, which was adopted by the German federal parliament on June 30 and entered into force on August 6, 2011, must be judged in the light of its genesis. Federal Chancellor Merkel, in her government declaration of June 9, 2011, had mentioned topics such as residual risk, safety standards, and risk assumptions, on which the federal government, in the week after the event of March 11, 2011, had commissioned the Advisory Committee on Reactor Safeguards (RSK) to conduct a comprehensive safety review of all German nuclear power plants, and appointed an Ethics Committee to write an opinion on safe energy supply. On the basis of quickly drafted reports, the federal cabinet, without any international harmonization (EU, IEA), adopted a draft opt out law on June 6, 2011. How should the declarations by the Federal Chancellor on June 9, 2011 be classified in terms of atomic energy law? In her words, it all revolved around the residual risk. The debate, which has been shifted to the realm of constitutional law, is open to considerations and steps to attack the new opt out law on grounds of material unconstitutionality (violation of the property guarantee under Sec. 14 or the principle of equality under Art.3 of the Basic Law). As far as final storage is concerned, the amendment to the German Atomic Energy Act announced still for this year, also for transposition of the EURATOM Directive of July 19, 2011 about nuclear waste management, the ''re-assessment of the residual risk'' is not likely to play a role. All these events are reminiscent of a sentence by former Federal Chancellor Schmidt: ''The history of the NATO dual-track decision remains a textbook case showing that even in a democracy emotions using ethical arguments, mixed with demagogy, can become strong enough to cast aside balanced reason.'' There is also a distinction by Max Weber between ''ethics of ideology

  3. Monitoring of Pesticide Residues in Commonly Used Fruits and Vegetables in Kuwait.

    Science.gov (United States)

    Jallow, Mustapha F A; Awadh, Dawood G; Albaho, Mohammed S; Devi, Vimala Y; Ahmad, Nisar

    2017-07-25

    The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers. The aim of this study was to assess the level of pesticide residues in commonly consumed fruits and vegetables in Kuwait. A total of 150 samples of different fresh vegetables and fruits were analyzed for the presence of 34 pesticides using the quick easy cheap effective rugged and safe (QuEChERS) multi-residue extraction, followed by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC - MS / MS). Pesticide residues above the maximum residue limits (MRL) were detected in 21% of the samples and 79% of the samples had no residues of the pesticides surveyed or contained residues below the MRL. Multiple residues were present in 40% of the samples with two to four pesticides, and four samples were contaminated with more than four pesticide residues. Of the pesticides investigated, 16 were detected, of which imidacloprid, deltamethrin, cypermethrin, malathion, acetamiprid, monocrotophos, chlorpyrifos-methyl, and diazinon exceeded their MRLs. Aldrin, an organochlorine pesticide, was detected in one apple sample, with residues below the MRL. The results indicate the occurrence of pesticide residues in commonly consumed fruits and vegetables in Kuwait, and pointed to an urgent need to develop comprehensive intervention measures to reduce the potential health risk to consumers. The need for the regular monitoring of pesticide residues and the sensitization of farmers to better pesticide safety practices, especially the need to adhere to recommended pre-harvest intervals is recommended.

  4. Monitoring of Pesticide Residues in Commonly Used Fruits and Vegetables in Kuwait

    Directory of Open Access Journals (Sweden)

    Mustapha F. A. Jallow

    2017-07-01

    Full Text Available The presence of pesticide residues in primary and derived agricultural products raises serious health concerns for consumers. The aim of this study was to assess the level of pesticide residues in commonly consumed fruits and vegetables in Kuwait. A total of 150 samples of different fresh vegetables and fruits were analyzed for the presence of 34 pesticides using the quick easy cheap effective rugged and safe (QuEChERS multi-residue extraction, followed by gas chromatography-mass spectrometry (GC-MS or liquid chromatography-tandem mass spectrometry (LC-MS/MS. Pesticide residues above the maximum residue limits (MRL were detected in 21% of the samples and 79% of the samples had no residues of the pesticides surveyed or contained residues below the MRL. Multiple residues were present in 40% of the samples with two to four pesticides, and four samples were contaminated with more than four pesticide residues. Of the pesticides investigated, 16 were detected, of which imidacloprid, deltamethrin, cypermethrin, malathion, acetamiprid, monocrotophos, chlorpyrifos-methyl, and diazinon exceeded their MRLs. Aldrin, an organochlorine pesticide, was detected in one apple sample, with residues below the MRL. The results indicate the occurrence of pesticide residues in commonly consumed fruits and vegetables in Kuwait, and pointed to an urgent need to develop comprehensive intervention measures to reduce the potential health risk to consumers. The need for the regular monitoring of pesticide residues and the sensitization of farmers to better pesticide safety practices, especially the need to adhere to recommended pre-harvest intervals is recommended.

  5. Residues and risks of veterinary antibiotics in protected vegetable soils following application of different manures.

    Science.gov (United States)

    Zhang, Haibo; Zhou, Yang; Huang, Yujuan; Wu, Longhua; Liu, Xinghua; Luo, Yongming

    2016-06-01

    The protected vegetable farming is a style of high frequent rotation farming which requires a huge amount of fertilizers to maintain soil fertility. A total of 125 surface soils covering from east to west of China were sampled for the analysis of 17 antibiotics in order to identify antibiotics contamination caused by long-term manures application. The results indicate that the agricultural land has accumulated a statistically significantly higher antibiotics concentration than conventional open croplands. The maximum oxytetracycline concentration was 8400 μg kg(-1), the highest level that has ever been reported for oxytetracycline in soils. The residual concentration is decided by both plant duration and manure type. Short-term (antibiotics residue in the soils on the whole. Principal component analysis suggests that the various combinations of antibiotic compounds in the soil may be used to trace the manure source. The antibiotics in soil may threaten water quality through contamination by diffusion. Ciprofloxacin and sulfachinoxalin are calculated to be a higher migration risk to surface waters, hence their environmental fate requires further study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Residual Structures in Latent Growth Curve Modeling

    Science.gov (United States)

    Grimm, Kevin J.; Widaman, Keith F.

    2010-01-01

    Several alternatives are available for specifying the residual structure in latent growth curve modeling. Two specifications involve uncorrelated residuals and represent the most commonly used residual structures. The first, building on repeated measures analysis of variance and common specifications in multilevel models, forces residual variances…

  7. Entropy Coherent and Entropy Convex Measures of Risk

    NARCIS (Netherlands)

    Laeven, R.J.A.; Stadje, M.A.

    2011-01-01

    We introduce two subclasses of convex measures of risk, referred to as entropy coherent and entropy convex measures of risk. We prove that convex, entropy convex and entropy coherent measures of risk emerge as certainty equivalents under variational, homothetic and multiple priors preferences,

  8. Design of specimen for weld residual stress simulation

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Park, Jong Sun; Lee, Kyung Soo

    2008-01-01

    The objective of this study is to design a laboratory specimen for simulating residual stress of circumferential butt welding of pipe. Specimen type and method for residual stress generation were proposed based on the review of prior studies and parametric finite element simulation. To prove the proposed specimen type and loading method, the residual stress was generated using the designed specimen by applying proposed method and was measured. The measured residual stress using X-ray diffraction reasonably agreed with the results of finite element simulation considered in the specimen design. Comparison of residual strains measured at several locations of specimen and given by finite element simulation also showed good agreement. Therefore, it is indicated that the designed specimen can reasonably simulate the residual stress of circumferential butt welding of pipe

  9. Favorable Local Control From Consolidative Radiation Therapy in High-Risk Neuroblastoma Despite Gross Residual Disease, Positive Margins, or Nodal Involvement

    Energy Technology Data Exchange (ETDEWEB)

    Ferris, Matthew J., E-mail: mjferri@emory.edu [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Danish, Hasan [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Switchenko, Jeffrey M. [Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Department of Biostatistics and Bioinformatics, Emory University, Atlanta, Georgia (United States); Deng, Claudia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); George, Bradley A.; Goldsmith, Kelly C.; Wasilewski, Karen J.; Cash, W. Thomas [Aflac Cancer and Blood Disorders Center, Children' s Healthcare of Atlanta, Atlanta, Georgia (United States); Khan, Mohammad K.; Eaton, Bree R.; Esiashvili, Natia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2017-03-15

    Purpose: To report the influence of radiation therapy (RT) dose and surgical pathology variables on disease control and overall survival (OS) in patients treated for high-risk neuroblastoma at a single institution. Methods and Materials: We conducted a retrospective study of 67 high-risk neuroblastoma patients who received RT as part of definitive management from January 2003 until May 2014. Results: At a median follow-up of 4.5 years, 26 patients (38.8%) failed distantly; 4 of these patients also failed locally. One patient progressed locally without distant failure. Local control was 92.5%, and total disease control was 59.5%. No benefit was demonstrated for RT doses over 21.6 Gy with respect to local relapse–free survival (P=.55), disease-free survival (P=.22), or OS (P=.72). With respect to local relapse–free survival, disease-free survival, and OS, no disadvantage was seen for positive lymph nodes on surgical pathology, positive surgical margins, or gross residual disease. Of the patients with gross residual disease, 75% (6 of 8) went on to have no evidence of disease at time of last follow-up, and the 2 patients who failed did so distantly. Conclusions: Patients with high-risk neuroblastoma in this series maintained excellent local control, with no benefit demonstrated for radiation doses over 21.6 Gy, and no disadvantage demonstrated for gross residual disease after surgery, positive surgical margins, or pathologic lymph node positivity. Though the limitations of a retrospective review for an uncommon disease must be kept in mind, with small numbers in some of the subgroups, it seems that dose escalation should be considered only in exceptional circumstances.

  10. Measurement of the fluorescence of crop residues: A tool for controlling soil erosion

    Science.gov (United States)

    Daughtry, C. S. T.; Mcmurtrey, J. E., III; Chappelle, E. W.; Hunter, W. J.

    1994-01-01

    Management of crop residues, the portion of a crop left in the field after harvest, is an important conservation practice for minimizing soil erosion and for improving water quality. Quantification of crop residue cover is required to evaluate the effectiveness of conservation tillage practices. Methods are needed to quantify residue cover that are rapid, accurate, and objective. The fluorescence of crop residue was found to be a broadband phenomenon with emission maxima at 420 to 495 nm for excitations of 350 to 420 nm. Soils had low intensity broadband emissions over the 400 to 690 nm region for excitations of 300 to 600 nm. The range of relative fluorescence intensities for the crop residues was much greater than the fluorescence observed of the soils. As the crop residues decompose their blue fluorescence values approach the fluorescence of the soil. Fluorescence techniques are concluded to be less ambiguous and better suited for discriminating crop residues and soils than reflectance methods. If properly implemented, fluorescence techniques can be used to quantify, not only crop residue cover, but also photosynthetic efficiency in the field.

  11. Measurement of the Residual Sodium and Reaction Compounds on a Cleaned Cold Trap

    International Nuclear Information System (INIS)

    Kim, Byung Ho; Jeong, Ji Young; Kim, Jong Man; Choi, Byung Hae; Nam, Ho Yun Nam

    2006-01-01

    The purpose of a cleaning process is to remove the residual sodium adhering to the component walls once it has been properly drained. It is necessary to clean and decontaminate a component, especially the large components of the primary coolant system; such as the intermediate heat exchangers and the primary pump. Improper and inadequate cleaning has in a number of cases resulted in problems in the storage, handling, and reuse of components. Inadequate and incomplete removal of sodium results in residues which may contain metallic sodium and alkaline compounds such as sodium hydroxide, sodium oxide, sodium carbonate, and various types of alcoholates. Reinsertion of components containing these compounds into a high-temperature sodium system can result in either a intergranular penetration characteristic of a high-oxygen sodium or an accelerated corrosion due to oxygen. Cleaning methods are needed that will avoid a deleterious local overheating, material surface degradation or deposits, a chemical, physical, or mechanical damage, and external effects. It is important to determine the levels of residual sodium that can be accepted so that those deleterious effects will not negate the reuse of the component. The purpose of this paper is to measure the amount of the sodium and the reaction compounds remaining on a component after a cleaning and prepare acceptable criteria for the reuse of components which have been subjected to a sodium cleaning

  12. Risk importance measures in the dynamic flowgraph methodology

    International Nuclear Information System (INIS)

    Tyrväinen, T.

    2013-01-01

    This paper presents new risk importance measures applicable to a dynamic reliability analysis approach with multi-state components. Dynamic reliability analysis methods are needed because traditional methods, such as fault tree analysis, can describe system's dynamical behaviour only in limited manner. Dynamic flowgraph methodology (DFM) is an approach used for analysing systems with time dependencies and feedback loops. The aim of DFM is to identify root causes of a top event, usually representing the system's failure. Components of DFM models are analysed at discrete time points and they can have multiple states. Traditional risk importance measures developed for static and binary logic are not applicable to DFM as such. Some importance measures have previously been developed for DFM but their ability to describe how components contribute to the top event is fairly limited. The paper formulates dynamic risk importance measures that measure the importances of states of components and take the time-aspect of DFM into account in a logical way that supports the interpretation of results. Dynamic risk importance measures are developed as generalisations of the Fussell-Vesely importance and the risk increase factor. -- Highlights: • New risk importance measures are developed for the dynamic flowgraph methodology. • Dynamic risk importance measures are formulated for states of components. • An approach to handle failure modes of a component in DFM is presented. • Dynamic risk importance measures take failure times into account. • Component's influence on the system's reliability can be analysed in detail

  13. Residual risk over-estimated

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The way nuclear power plants are built practically excludes accidents with serious consequences. This is attended to by careful selection of material, control of fabrication and regular retesting as well as by several safety systems working independently. But the remaining risk, a 'hypothetic' uncontrollable incident with catastrophic effects is the main subject of the discussion on the peaceful utilization of nuclear power. The this year's 'Annual Meeting on Nuclear Engineering' in Mannheim and the meeting 'Reactor Safety Research' in Cologne showed, that risk studies so far were too pessimistic. 'Best estimate' calculations suggest that core melt-down accidents only occur if almost all safety systems fail, that accidents take place much more slowly, and that the release of radioactive fission products is by several magnitudes lower than it was assumed until now. (orig.) [de

  14. The Application of Asymmetric Liquidity Risk Measure in Modelling the Risk of Investment

    Directory of Open Access Journals (Sweden)

    Garsztka Przemysław

    2015-06-01

    Full Text Available The article analyses the relationship between investment risk (as measured by the variance of returns or standard deviation of returns and liquidity risk. The paper presents a method for calculating a new measure of liquidity risk, based on the characteristic line. In addition, it is checked what is the impact of liquidity risk to the volatility of daily returns. To describe this relationship dynamic econometric models were used. It was found that there was an econometric relationship between the proposed measure liquidity risk and the variance of returns.

  15. Statistical properties of proportional residual energy intake as a new measure of energetic efficiency.

    Science.gov (United States)

    Zamani, Pouya

    2017-08-01

    Traditional ratio measures of efficiency, including feed conversion ratio (FCR), gross milk efficiency (GME), gross energy efficiency (GEE) and net energy efficiency (NEE) may have some statistical problems including high correlations with milk yield. Residual energy intake (REI) or residual feed intake (RFI) is another criterion, proposed to overcome the problems attributed to the traditional ratio criteria, but it does not account for production or intake levels. For example, the same REI value could be considerable for low producing and negligible for high producing cows. The aim of this study was to propose a new measure of efficiency to overcome the problems attributed to the previous criteria. A total of 1478 monthly records of 268 lactating Holstein cows were used for this study. In addition to FCR, GME, GEE, NEE and REI, a new criterion called proportional residual energy intake (PREI) was calculated as REI to net energy intake ratio and defined as proportion of net energy intake lost as REI. The PREI had an average of -0·02 and range of -0·36 to 0·27, meaning that the least efficient cow lost 0·27 of her net energy intake as REI, while the most efficient animal saved 0·36 of her net energy intake as less REI. Traditional ratio criteria (FCR, GME, GEE and NEE) had high correlations with milk and fat corrected milk yields (absolute values from 0·469 to 0·816), while the REI and PREI had low correlations (0·000 to 0·069) with milk production. The results showed that the traditional ratio criteria (FCR, GME, GEE and NEE) are highly influenced by production traits, while the REI and PREI are independent of production level. Moreover, the PREI adjusts the REI magnitude for intake level. It seems that the PREI could be considered as a worthwhile measure of efficiency for future studies.

  16. Risk measures in practical use: risk reduction has its price, but is it known?

    International Nuclear Information System (INIS)

    Reinertsen, Rune

    1995-01-01

    Different risk measures are discussed in order to decide which to use to best express the risk workers are exposed to. A new risk measure is introduced and advantages and disadvantages are presented. The need for a new risk measure (Expected Number of Fatalities Rate ENFR), is discussed and explained with the help of an example. The example also contains a comparison with the well-known FAR-value. Also some problems and benefits of introducing a measure of the kind: ΔRISK/Δ$ are discussed and conclusions made. The question of what amount of money should be used on risk reducing activities is also addressed

  17. Modeling returns volatility: Realized GARCH incorporating realized risk measure

    Science.gov (United States)

    Jiang, Wei; Ruan, Qingsong; Li, Jianfeng; Li, Ye

    2018-06-01

    This study applies realized GARCH models by introducing several risk measures of intraday returns into the measurement equation, to model the daily volatility of E-mini S&P 500 index futures returns. Besides using the conventional realized measures, realized volatility and realized kernel as our benchmarks, we also use generalized realized risk measures, realized absolute deviation, and two realized tail risk measures, realized value-at-risk and realized expected shortfall. The empirical results show that realized GARCH models using the generalized realized risk measures provide better volatility estimation for the in-sample and substantial improvement in volatility forecasting for the out-of-sample. In particular, the realized expected shortfall performs best for all of the alternative realized measures. Our empirical results reveal that future volatility may be more attributable to present losses (risk measures). The results are robust to different sample estimation windows.

  18. Estimation of residual stress in cold rolled iron-disks from strain measurements on the high resolution Fourier diffractometer

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Balagurov, A.M.; Taran, Yu.V.

    1995-01-01

    The results of estimating residual stresses in cold rolled iron disks by measurements with the high resolution Fourier diffractometer (HRFD) at the IBR-2 pulsed reactor are presented. These measurements were made for calibration of magnetic and ultrasonic measurements carried out at the Fraunhofer-Institute for Nondestructive Testing in Saarbrucken (Germany). The tested objects were cold rolled steel disks of 2.5 mm thickness and diameter of about 500 mm used for forming small, gas pressure tanks. Neutron diffraction experiments were carried out at the scattering angle 2θ=+152 d eg with resolution Δd/d=1.5·10 -3 . The gauge volume was chosen according to the magnetic measurements lateral resolution 20x20 mm 2 . In the nearest future the neutron diffraction measurements with cold rolled iron disks at the scattering angle 2θ=±90 0 are planned. Also the texture analysis will be included in the Rietveld refinement procedure for more correct calculation of residual stress fields in the cold rolled materials. 8 refs., 10 figs., 1 tab

  19. Basel III Liquidity Risk Measures and Bank Failure

    Directory of Open Access Journals (Sweden)

    L. N. P. Hlatshwayo

    2013-01-01

    Full Text Available Basel III banking regulation emphasizes the use of liquidity coverage and nett stable funding ratios as measures of liquidity risk. In this paper, we approximate these measures by using global liquidity data for 391 hand-selected, LIBOR-based, Basel II compliant banks in 36 countries for the period 2002 to 2012. In particular, we compare the risk sensitivity of the aforementioned Basel III liquidity risk measures to those of traditional measures such as the nonperforming assets ratio, return-on-assets, LIBOR-OISS, Basel II Tier 1 capital ratio, government securities ratio, and brokered deposits ratio. Furthermore, we use a discrete-time hazard model to study bank failure. In this regard, we find that Basel III risk measures have limited ability to predict bank failure when compared with their traditional counterparts. An important result is that a higher liquidity coverage ratio is associated with a higher bank failure rate. We also find that market-wide liquidity risk (proxied by LIBOR-OISS was the major predictor of bank failures in 2009 and 2010 while idiosyncratic liquidity risk (proxied by other liquidity risk measures was less. In particular, our contribution is the first to achieve these results on a global scale over a relatively long period for a variety of banks.

  20. Effect of residual stress on the integrity of a branch connection

    International Nuclear Information System (INIS)

    Law, M.; Kirstein, O.; Luzin, V.

    2012-01-01

    A new connection to an existing gas pipeline was made by hot-tapping, welding directly onto a pressurised pipeline. The welds were not post-weld heat treated, causing significant residual stresses. The critical weld had residual stresses determined by neutron diffraction using ANSTO's residual stress diffractometer, Kowari. The maximum measured residual stress (290 MPa) was 60% of the yield strength. The magnitudes of errors from a number of sources were estimated. An integrity assessment of the welded branch connection was performed with the measured residual stress values and with residual stress distributions from the BS 7910 and API 579 analysis codes. Analysis using estimates of residual stress from API 579 overestimated the critical crack size. Highlights: ► Residual stresses were measured by neutron diffraction in a thick section, non post-weld heat treated ferritic weld. ► There is little published data on these welds. ► The work compares the measured residual stresses with code-based residual stress distributions.

  1. Residual stresses in a composite steel tube measured by neutron diffraction

    International Nuclear Information System (INIS)

    Taran, Yu.V.; Balagurov, A.M.; Zlokazov, V.B.; Schreiber, J.; Stuhr, U.; Kockelmann, H.

    2006-01-01

    The triaxial residual stresses in a composite tube from an austenitic stainless steel with a welded ferritic steel cladding were measured by the time-of-flight neutron diffraction method on the POLDI instrument at the PSI SINQ facility. The POLDI results are compared to the results obtained by the destructive turning out method and theoretical predictions of calculations by the finite element method. Only for the tangential component of the stress tensor the semiquantitative agreement of all used methods was observed. There is a clear discrepancy between the results of the different methods in the axial component. For the radial component all methods reveal quite small stresses, however, with some distinct differences in their distributions

  2. Stresses and residual stresses optical measurements systems evaluation; Avaliacao de sistemas opticos de medicao de tensoes e tensoes residuais em dutos

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto Filho, Flavio Tito; Goncalves Junior, Armando Albertazzi [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Lab. de Metrologia e Automatizacao (LABMETRO)

    2004-07-01

    There is always a constant concern about the pipelines' integrity. An important control parameter is the level of total mechanical stresses acting over the pipeline. However, the loading and residual stresses acting on a pipeline are not measured in the field as much as necessary. Technical difficulties and the high cost of the nowadays techniques and the hostile measurement conditions are the main reason for that. An alternative method has been developed at the Universidade Federal de Santa Catarina (UFSC) since 1992. A new optical measurement device is used to measure strains, mechanical stresses and residual stresses acting over the structure. A metrological and functional evaluation of this system is the main focus of this paper. (author)

  3. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    Science.gov (United States)

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  4. Influence of cooling rate on residual stress profile in veneering ceramic: measurement by hole-drilling.

    Science.gov (United States)

    Mainjot, Amélie K; Schajer, Gary S; Vanheusden, Alain J; Sadoun, Michaël J

    2011-09-01

    The manufacture of dental crowns and bridges generates residual stresses within the veneering ceramic and framework during the cooling process. Residual stress is an important factor that control the mechanical behavior of restorations. Knowing the stress distribution within the veneering ceramic as a function of depth can help the understanding of failures, particularly chipping, a well-known problem with Yttria-tetragonal-zirconia-polycrystal based fixed partial dentures. The objective of this study is to investigate the cooling rate dependence of the stress profile in veneering ceramic layered on metal and zirconia frameworks. The hole-drilling method, often used for engineering measurements, was adapted for use with veneering ceramic. The stress profile was measured in bilayered disc samples 20 mm in diameter, with a 0.7 mm thick metal or Yttria-tetragonal-zirconia-polycrystal framework and a 1.5mm thick veneering ceramic. Three different cooling procedures were investigated. The magnitude of the stresses in the surface of the veneering ceramic was found to increase with cooling rate, while the interior stresses decreased. At the surface, compressive stresses were observed in all samples. In the interior, compressive stresses were observed in metal samples and tensile in zirconia samples. Cooling rate influences the magnitude of residual stresses. These can significantly influence the mechanical behavior of metal-and zirconia-based bilayered systems. The framework material influenced the nature of the interior stresses, with zirconia samples showing a less favorable stress profile than metal. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Transfer shuttle for vitrified residue canisters control of risks associated with external exposure and heat release

    Energy Technology Data Exchange (ETDEWEB)

    BIndel, L.; Gamess, A.; Lejeune, E.; Cellier, P.; Maillard, A. [SGN Reseau Eurisys, 78 - Saint Quentin (France)

    1998-07-01

    In the La Hague COGEMA's plant area, nuclear residue isolated by reprocessing are transported by means of specific transfer shuttles between the different processing and/or conditioning facilities and the storage ones. These shuttles are designed by reference to the applicable dose equivalent rate (DER) limits for transport on the site and the thermal behavior limitations of certain mechanical components which guarantee the containment of the transported waste. This paper describes and example of a study conducted on a transfer shuttle for vitrified residue canisters. Concerning the control of risks associated with external exposure and with heat releases, these were handled by the 'Shielding-Criticality-Dispersion' and 'process Modelling and Simulation' Sections of the Technical Division of SGN. The dose profiles around the shuttle, as a function of the shielding heterogeneities and possible radiation leakage, as well as the thermal fields within the shuttle, were calculated using 3D models. These design studies ultimately helped to select and validate the optimal solutions. (authors)

  6. Analysis and measurement of residual stress distribution of vanadium/ceramics joints for fusion reactor applications

    International Nuclear Information System (INIS)

    Nemoto, Y.; Ueda, K.

    1998-01-01

    Vanadium alloys are considered as candidate structural materials for fusion reactor system. When vanadium alloys are used in fusion reactor system, joining with ceramics for insulating is one of material issues to be solved to make component of fusion reactor. In the application of ceramics/metal jointing and coating, residual stress caused by difference of thermal expansion rate between ceramics and metals is an important factor in obtaining good bonding strength and soundness of coating. In this work, residual stress distribution in direct diffusion bonded vanadium/alumina joint (jointing temperature: 1400 C) was measured by small area X-ray diffraction method. And the comparison of finite element method (FEM) analysis and actual stress distribution was carried out. Tensile stress concentration at the edge of the boundary of the joint in alumina was observed. The residual stress concentration may cause cracks in alumina, or failure of bonding. Actually, cracks in alumina caused by thermal stress after bonding at 1500 C was observed. The stress concentration of the joint must be reduced to obtain good bonded joint. Lower bonding temperature or to devise the shape of the outer surface of the joint will reduce the stress concentration. (orig.)

  7. Residual Stress Analysis Based on Acoustic and Optical Methods

    Directory of Open Access Journals (Sweden)

    Sanichiro Yoshida

    2016-02-01

    Full Text Available Co-application of acoustoelasticity and optical interferometry to residual stress analysis is discussed. The underlying idea is to combine the advantages of both methods. Acoustoelasticity is capable of evaluating a residual stress absolutely but it is a single point measurement. Optical interferometry is able to measure deformation yielding two-dimensional, full-field data, but it is not suitable for absolute evaluation of residual stresses. By theoretically relating the deformation data to residual stresses, and calibrating it with absolute residual stress evaluated at a reference point, it is possible to measure residual stresses quantitatively, nondestructively and two-dimensionally. The feasibility of the idea has been tested with a butt-jointed dissimilar plate specimen. A steel plate 18.5 mm wide, 50 mm long and 3.37 mm thick is braze-jointed to a cemented carbide plate of the same dimension along the 18.5 mm-side. Acoustoelasticity evaluates the elastic modulus at reference points via acoustic velocity measurement. A tensile load is applied to the specimen at a constant pulling rate in a stress range substantially lower than the yield stress. Optical interferometry measures the resulting acceleration field. Based on the theory of harmonic oscillation, the acceleration field is correlated to compressive and tensile residual stresses qualitatively. The acoustic and optical results show reasonable agreement in the compressive and tensile residual stresses, indicating the feasibility of the idea.

  8. Comparing downside risk measures for heavy tailed distributions

    NARCIS (Netherlands)

    Daníelsson, J.; Jorgensen, B.N.; Sarma, M.; Vries, de C.G.

    2006-01-01

    Using regular variation to define heavy tailed distributions, we show that prominent downside risk measures produce similar and consistent ranking of heavy tailed risk. Thus, regardless of the particular risk measure being used, assets will be ranked in a similar and consistent manner for heavy

  9. Application of in-plane x-ray diffraction technique for residual stress measurement of TiN film/WC-Co alloy

    International Nuclear Information System (INIS)

    Takago, Shigeki; Yasui, Haruyuki; Awazu, Kaoru; Sasaki, Toshihiko; Hirose, Yukio; Sakurai, Kenji

    2006-01-01

    An in-plane X-ray diffraction technique was used to measure the residual stress of a CVD (chemical vapor deposition) TiN-coated WC-Co alloy. We could obtain the diffraction pattern from a thin film layer, eliminating that of the substrate. In the case of a conventional X-ray diffractometer, the X-ray penetration depth is about few μm. However, for a grazing incidence beam it is only 0.2μm. Depth profiles of residual stress in TiN film layer were evaluated by the present method and the conventional sin 2 ψ technique. We concluded that the in-plane diffraction technique enables us to determine the residual stress in a DVD-TiN film having an oriented texture. It was found that the residual tensile stress generated a mismatch of the coefficient of thermal expansion between the film and the substrate. (author)

  10. Application of in-plane x-ray diffraction technique for residual stress measurement of TiN film/WC-Co alloy

    Energy Technology Data Exchange (ETDEWEB)

    Takago, Shigeki; Yasui, Haruyuki; Awazu, Kaoru [Industrial Research Inst. of Ishikawa, Kanazawa, Ishikawa (Japan); Sasaki, Toshihiko; Hirose, Yukio [Kanazawa Univ., Dept. of Materials Science and Engineering, Kanazawa, Ishikawa (Japan); Sakurai, Kenji [National Inst. for Materials Science, Tsukuba, Ibaraki (Japan)

    2006-06-15

    An in-plane X-ray diffraction technique was used to measure the residual stress of a CVD (chemical vapor deposition) TiN-coated WC-Co alloy. We could obtain the diffraction pattern from a thin film layer, eliminating that of the substrate. In the case of a conventional X-ray diffractometer, the X-ray penetration depth is about few {mu}m. However, for a grazing incidence beam it is only 0.2{mu}m. Depth profiles of residual stress in TiN film layer were evaluated by the present method and the conventional sin{sup 2}{psi} technique. We concluded that the in-plane diffraction technique enables us to determine the residual stress in a DVD-TiN film having an oriented texture. It was found that the residual tensile stress generated a mismatch of the coefficient of thermal expansion between the film and the substrate. (author)

  11. Measuring social risk and determining its acceptability

    International Nuclear Information System (INIS)

    Lathrop, J.W.

    1978-01-01

    The implementation of a nuclear waste management technology raises several issues concerning the regulation of social risk. This paper presents a decision analytic approach to resolving some of those issues. A methodology for developing a radiological risk measure is presented, and several approaches to defining acceptable levels of that risk measure are considered. The methodology presented is oriented toward the development of radiological performance objectives for use as guidance in the drafting of regulations

  12. Residual strains in girth-welded linepipe

    International Nuclear Information System (INIS)

    MacEwen, S.R.; Holden, T.M.; Powell, B.M.; Lazor, R.B.

    1987-07-01

    High resolution neutron diffraction has been used to measure the axial residual strains in and adjacent to a multipass girth weld in a complete section of 914 mm (36 inches) diameter, 16 mm (5/8 inch) wall, linepipe. The experiments were carried out at the NRU reactor, Chalk River using the L3 triple-axis spectrometer. The through-wall distribution of axial residual strain was measured at 0, 4, 8, 20 and 50 mm from the weld centerline; the axial variation was determined 1, 5, 8, and 13 mm from the inside surface of the pipe wall. The results have been compared with strain gauge measurements on the weld surface and with through-wall residual stress distributions determined using the block-layering and removal technique

  13. On-line measurement of residual monomer during polymerisation of acrylamide using ultrasonics

    International Nuclear Information System (INIS)

    Ponraju, D.; Sebastian, Letha; Viswanathan, S.; Natarajan, A.; Palanichamy, P.; Jayakumar, T.; Baldev Raj

    1996-01-01

    An ultrasonic technique for the estimation of residual acrylamide monomer during the polymerization of aqueous acrylamide solution has been investigated. Polyacrylamide gel medium serves as a sensitive medium for detection and dosimetry of fast and thermal neutrons. This technique is based on the fact that the velocity of ultrasonic wave increases with the increase in elasticity due to polymerization. The percentage of residual acrylamide monomer is estimated using ultraviolet spectrophotometric analysis. The ultrasonic velocity is correlated with the residual monomer concentration

  14. Linking Measured Risk Aversion to Individual Characteristics.

    NARCIS (Netherlands)

    Hartog, J.; Ferrer-i-Carbonell, A.; Jonker, N.

    2002-01-01

    From the stated price of a specified lottery in three unrelated surveys we deduce individuals' Arrow-Pratt measure of risk aversion. We find that risk aversion indeed falls with income and wealth. Entrepreneurs are less risk averse than employees, civil servants are more risk averse than private

  15. [Do pharmaceutical waste and drug residue pose a risk to public health?].

    Science.gov (United States)

    Haguenoer, Jean-Marie

    2010-01-01

    Recently, awareness has developed of the environmental consequences of drug waste and disposal. These residues are identified as coming from either diffuse sources, the most significant of which is via the discharge of these residues in urine and feces, and thus the sewage system and water contains these drug remnants and their metabolites, or from point sources, sometimes with very high levels of concentration in waste from chemical and pharmaceutical industries, health care settings, but also from intensive livestock farming and aquaculture. Depending on their physical chemistry properties, these substances are more or less naturally biodegradable and easily treated in sewage purification plants. The effectiveness of these treatment processes is highly random and unpredictable, but is overall around 60%, nevertheless with variations of 2-99% according to the molecules. The silt from these treatment plants, sometimes very rich in lipophilic substances is on occasion reused for agricultural application as fertilizer, paving the way for a possible contamination of crops. Furthermore, the use of veterinary drugs in animals can lead to soil contamination either directly or through manure and slurry. The contamination can equally reach and affect surface water, groundwater and sometimes the water intended for human consumption. The National academy of Pharmacy has established some general recommendations on the proper use of drugs, environmental monitoring and surveillance, risk assessment for humans and the environment, prevention and the need for prevention. Several categories of drugs are more worrying: cancer treatments, antibiotics as well as transfers of anti-bio-resistance, and hormonal derivatives which has been previously demonstrated to contribute, along with other molecules, to detrimental effects on endocrines.

  16. Measurement of residual stress by using focused ion beam and digital image correlation method in thin-sized wires used for steel cords

    International Nuclear Information System (INIS)

    Yang, Y S; Park, C G; Bae, J G

    2008-01-01

    Residual stress in the axial direction of the steel wires has been measured by using a method based on the combination of the focused ion beam (FIB) milling and digital image correlation software. That is, the residual stress was calculated from the measured displacement field before and after the introduction of a slot along the steel wires. The displacement was obtained by the digital correlation analysis of high-resolution scanning electron micrographs, while the slot was introduced by FIB milling with low energy beam. The fitting of the experimental results to an analytical model with the independent Young's modulus determined allows us to find the residual stress. The complete experimental procedures are described and its feasibilities are also evaluated for the thin-sized steel wires

  17. Surface preparation for XRD residual stress measurements; Preparacao de superficie para medicao de tensoes residuais em soldagem por DRX

    Energy Technology Data Exchange (ETDEWEB)

    Mishchenko, Andrii; Oliveira, Bruno Jose de; Scotti, Americo, E-mail: asmwelder@gmail.com, E-mail: brunojoliveira7@gmail.com, E-mail: ascotti@mecanica.ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil)

    2016-10-15

    A characteristic feature of the X Ray Diffraction (XRD) method for stress determination is that measurements occur at a thin surface layer. Steel sheets come with surfaces modified by lamination, cleaning (sandblasting, grinding) and even corrosion, which induce residual stresses or roughness inherent to the material. Therefore, surface preparation prior to the residual stress measurement is essential, although no standard procedure seems to be available. A general recommendation is to remove a thin layer so that only residual stresses related to the welding process will be measured. In this study, the use of portable electrolytic equipment was evaluated for mechanized surface material removal. Chemical compositions of electrolytic solutions and the influence of current on the removed material, removal time and temperature during the process were studied. As a result, a suitable chemical solution for electro etching of low carbon steel was developed and a set of “soft” parameters that allowed the removal of about 300 um in a reasonable time was found. Higher currents reduce the removal time, yet increasing the consumption of the solution and plate temperature (which could adversely alter the microstructure or generate thermal stresses). Furthermore, the influence of these parameters on the operability of the process was demonstrated. (author)

  18. Beyond statin therapy: a review of the management of residual risk in diabetes mellitus.

    LENUS (Irish Health Repository)

    Judge, Eoin P

    2010-09-01

    Total cholesterol and low-density lipoprotein (LDL) cholesterol exhibit an independent, strong, continuous correlation with cardiovascular events. The effectiveness of hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) in the treatment and prevention of atherosclerosis is well-established. However, despite the lowering of LDL targets and the increased use of statins, patients with type 2 diabetes mellitus (DM) continue to experience a higher proportion of adverse coronary artery disease events. This is as a result of an atherogenic dyslipidaemia, characterized by low levels of high-density lipoprotein and elevated plasma triglyceride concentrations, often with high levels of cholesterol-rich remnant particles. This article will review dyslipidaemia and its role in DM, and will discuss available treatment modalities that address residual cardiovascular risk in this disease.

  19. New Risk Measure and Idiosyncratic Risk in Taiwan Stock Market

    OpenAIRE

    Yin-Ching Jan; Su-Ling Chiu; Jerry M. C. Wang

    2013-01-01

    Under the model developed by Merton (1987), the idiosyncratic risk would be important to explain the expected stock return. We follow the approach of Daniel and Titman (1998), and use the risk measure developed by Jan and Wang (2012) to examine whether idiosyncratic risk can play an important role in explaining the expected return in Taiwan stock market. We find that beta can¡¯t explain the expected return, and that idiosyncratic risk has a positive relation to expected returns for stocks wit...

  20. Health condition and residual life of deteriorating technical systems

    Energy Technology Data Exchange (ETDEWEB)

    Reinertsen, Rune

    1998-12-31

    Many offshore installations in the Norwegian Sector of the North Sea approach the end of their useful life. The same is true of many power plants and technical systems in general. This thesis describes the theory and improves the methods for the determination of the health condition and residual life of technical systems. Rather than developing new methods it discusses new ways of using existing statistical methods. The main contributions are: (1) A survey of the literature of diagnosis, prediction and life extension for deteriorating technical systems, (2) A discussion of some consequences of selecting the wrong life model, (3) A description of problems related to the determination of mean residual life of non-repairable technical systems, (4) Presentation of the concept of `technical health` to describe the soundness of a system exposed to failure mechanisms, (5) A model for predicting the technical health and residual life of a corroding system, (6) Recommends requirements and methods for using expert knowledge in safety and reliability analysis, (7) A general inspection strategy for system fault diagnosis by using Shannon entropy, (8) Points out weaknesses and strengths of risk measures used in the offshore industry today. 237 refs., 23 figs., 6 tabs.

  1. Health condition and residual life of deteriorating technical systems

    Energy Technology Data Exchange (ETDEWEB)

    Reinertsen, Rune

    1997-12-31

    Many offshore installations in the Norwegian Sector of the North Sea approach the end of their useful life. The same is true of many power plants and technical systems in general. This thesis describes the theory and improves the methods for the determination of the health condition and residual life of technical systems. Rather than developing new methods it discusses new ways of using existing statistical methods. The main contributions are: (1) A survey of the literature of diagnosis, prediction and life extension for deteriorating technical systems, (2) A discussion of some consequences of selecting the wrong life model, (3) A description of problems related to the determination of mean residual life of non-repairable technical systems, (4) Presentation of the concept of `technical health` to describe the soundness of a system exposed to failure mechanisms, (5) A model for predicting the technical health and residual life of a corroding system, (6) Recommends requirements and methods for using expert knowledge in safety and reliability analysis, (7) A general inspection strategy for system fault diagnosis by using Shannon entropy, (8) Points out weaknesses and strengths of risk measures used in the offshore industry today. 237 refs., 23 figs., 6 tabs.

  2. Residual stress profiles in veneering ceramic on Y-TZP, alumina and ZTA frameworks: measurement by hole-drilling.

    Science.gov (United States)

    Fukushima, K A; Sadoun, M J; Cesar, P F; Mainjot, A K

    2014-02-01

    The residual stress profile developed within the veneering ceramic during the manufacturing process is an important predicting factor in chipping failures, which constitute a well-known problem with yttria-tetragonal-zirconia polycrystal (Y-TZP) based restorations. The objectives of this study are to measure and to compare the residual stress profile in the veneering ceramic layered on three different polycrystalline ceramic framework materials: Y-TZP, alumina polycrystal (AL) and zirconia toughened alumina (ZTA). The stress profile was measured with the hole-drilling method in bilayered disk samples of 19 mm diameter with a 0.7 mm thick Y-TZP, AL or ZTA framework and a 1.5mm thick layer of the corresponding veneering ceramic. The AL samples exhibited increasing compressive stresses with depth, while compressive stresses switching into interior tensile stresses were measured in Y-TZP samples. ZTA samples exhibited compressive stress at the ceramic surface, decreasing with depth up to 0.6mm from the surface, and then becoming compressive again near the framework. Y-TZP samples exhibited a less favorable stress profile than those of AL and ZTA samples. Results support the hypothesis of the occurrence of structural changes within the Y-TZP surface in contact with the veneering ceramic to explain the presence of tensile stresses. Even if the presence of Y-TZP in the alumina matrix seems to negatively affect the residual stress profiles in ZTA samples in comparison with AL samples, the registered profiles remain positive in terms of veneer fracture resistance. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Detection of Residual Levels and Associated Health Risk of Seven Pesticides in Fresh Eggplant and Tomato Samples from Narayanganj District, Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Nur Alam

    2015-01-01

    Full Text Available Residual levels of seven frequently used pesticides were investigated in 140 samples of two common vegetables, eggplants and tomatoes, from agricultural fields in the Narayanganj district of Bangladesh. The analysis of pesticide residues was performed by high-performance liquid chromatography with photodiode array detection. A large percentage of the eggplants (50% and tomatoes (60% from the Narayanganj district were contaminated with pesticides, and all of the levels were above the maximum residual limit (MRL proposed by the EC regulation. Diazinon was the most common (35% pesticide detected in the vegetable samples at a concentration of 45–450 times higher than the MRL. The health risk index for diazinon was highest for both eggplant and tomato samples, which may be due to its physiochemical properties. Fenitrothion and linuron are the two second most common types of pesticides detected in the vegetable samples. Regular monitoring of the use of common pesticides on vegetables should be conducted.

  4. Some new classes of consistent risk measures

    NARCIS (Netherlands)

    Goovaerts, M.J.; Kaas, R.; Dhaene, J.L.M.; Tang, Q.

    2004-01-01

    Many types of insurance premium principles and/or risk measures can be characterized by means of a set of axioms, which in many cases are rather arbitrarily chosen and not always in accordance with economic reality. In the present paper we generalize Yaari¿s risk measure by relaxing his axioms. In

  5. A non-Gaussian approach to risk measures

    Science.gov (United States)

    Bormetti, Giacomo; Cisana, Enrica; Montagna, Guido; Nicrosini, Oreste

    2007-03-01

    Reliable calculations of financial risk require that the fat-tailed nature of prices changes is included in risk measures. To this end, a non-Gaussian approach to financial risk management is presented, modelling the power-law tails of the returns distribution in terms of a Student- t distribution. Non-Gaussian closed-form solutions for value-at-risk and expected shortfall are obtained and standard formulae known in the literature under the normality assumption are recovered as a special case. The implications of the approach for risk management are demonstrated through an empirical analysis of financial time series from the Italian stock market and in comparison with the results of the most widely used procedures of quantitative finance. Particular attention is paid to quantify the size of the errors affecting the market risk measures obtained according to different methodologies, by employing a bootstrap technique.

  6. Measurement of adherence of residually stressed thin films by indentation. I. Mechanics of interface delamination

    International Nuclear Information System (INIS)

    Marshall, D.B.; Evans, A.G.

    1984-01-01

    A fracture analysis of indentation-induced delamination of thin films is presented. The analysis is based on a model system in which the section of film above the delaminating crack is treated as a rigidly clamped disc, and the crack extension force is derived from changes in strain energy of the system as the crack extends. Residual deposition stresses influence the cracking response by inducing buckling of the film above the crack and by providing an additional crack driving force once buckling occurs. A relation for the equilibrium crack length is derived in terms of the indenter load and geometry, the film thickness and mechanical properties, the residual stress level and the fracture toughness of the interface. The analysis provides a basis for using controlled indentation cracking as a quantitative measure of interface toughness and for evaluating contact-induced damage in thin films

  7. Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling.

    Science.gov (United States)

    Mainjot, Amélie K; Schajer, Gary S; Vanheusden, Alain J; Sadoun, Michaël J

    2012-02-01

    The veneering process of frameworks induces residual stresses and can initiate cracks when combined with functional stresses. The stress distribution within the veneering ceramic as a function of depth is a key factor influencing failure by chipping. This is a well-known problem with Yttria-tetragonal-zirconia-polycrystal based fixed partial dentures. The objective of this study is to investigate the influence of veneer thickness on the stress profile in zirconia- and metal-based structures. The hole-drilling method, often used for engineering measurements, was adapted for use with veneering ceramic. The stress profile was measured in bilayered disc samples of 20 mm diameter, with a 1 mm thick zirconia or metal framework. Different veneering ceramic thicknesses were performed: 1 mm, 1.5 mm, 2 mm, 2.5 mm and 3 mm. All samples exhibited the same type of stress vs. depth profile, starting with compressive at the ceramic surface, decreasing with depth up to 0.5-1.0 mm from the surface, and then becoming compressive again near the framework, except for the 1.5 mm-veneered zirconia samples which exhibited interior tensile stresses. Stresses in the surface of metal samples were not influenced by veneer thickness. Variation of interior stresses at 1.2 mm from the surface in function of veneer thickness was inverted for metal and zirconia samples. Veneer thickness influences in an opposite way the residual stress profile in metal- and in zirconia-based structures. A three-step approach and the hypothesis of the crystalline transformation are discussed to explain the less favorable residual stress development in zirconia samples. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Enzymatic activity measured by microcalorimetry in soil amended with organic residues

    Directory of Open Access Journals (Sweden)

    Karina Cenciani

    2011-08-01

    Full Text Available Enzymatic activity is an important property for soil quality evaluation. Two sequences of experiments were carried out in order to evaluate the enzymatic activity in a soil (Rhodic Eutrudox amended with cattle manure, earthworm casts, or sewage sludges from the municipalities of Barueri and Franca. The activity of commercial enzymes was measured by microcalorimetry in the same soil samples after sterilization. In the first experiment, the enzyme activities of cellulase, protease, and urease were determined in the soil samples during a three month period. In the second sequence of experiments, the thermal effect of the commercial enzymes cellulase, protease, and urease on sterilized soil samples under the same tretaments was monitored for a period of 46 days. The experimental design was randomized and arranged as factorial scheme in five treatments x seven samplings with five replications. The treatment effects were statistically evaluated by one-way analysis of variance. Tukey´s test was used to compare means at p < 0.05. The presence of different sources of organic residues increased the enzymatic activity in the sampling period. Cattle manure induced the highest enzymatic activity, followed by municipal sewage sludge, whereas earthworm casts induced the lowest activity, but differed from control treatment. The thermal effect on the enzyme activity of commercial cellulase, protease, and urease showed a variety of time peaks. These values probably oscillated due to soil physical-chemical factors affecting the enzyme activity on the residues.

  9. The Continuation Study of the Measurement of Residual Monomer from theDenture Base After Three Month Worn by Gas Chromatography on the Radiationand Non Radiation Worker

    International Nuclear Information System (INIS)

    Isyuniarto; Winoto

    2000-01-01

    Residual monomer measurement on the radiation and non radiation workerafter three month worn the denture has been done. The aim of the research isto investigated residual monomer concentration on after three month worn. Thedenture base material, made of resin acrylic, sometimes is cause mucosairritation in the mouth, and dental irritation or allergic reaction, becauseof residual monomer that left on the mouth cavity. In this research two groupwere needed there are the radiation and non radiation worker, the level ofthe residual monomer count by gas chromatography analysis. The result of thisresearch showed that the level of residual monomer of two group are same orthere have same level of the limit value. The measurement result is in therange of 0.1783 ± 0.011 mg/l to 0.1790 ± 0.004 mg/l. (author)

  10. Evaluation of Residual Stresses using Ring Core Method

    Directory of Open Access Journals (Sweden)

    Holý S.

    2010-06-01

    Full Text Available The method for measuring residual stresses using ring-core method is described. Basic relations are given for residual stress measurement along the specimen depth and simplified method is described for average residual stress estimation in the drilled layer for known principal stress directions. The estimation of calculated coefficients using FEM is described. Comparison of method sensitivity is made with hole-drilling method. The device for method application is described and an example of experiment is introduced. The accuracy of method is discussed. The influence of strain gauge rosette misalignment to the evaluated residual stresses is performed using FEM.

  11. Social and ethical perspectives of landslide risk mitigation measures

    Science.gov (United States)

    Kalsnes, Bjørn; Vangelsten, Bjørn V.

    2015-04-01

    Landslide risk may be mitigated by use of a wide range of measures. Mitigation and prevention options may include (1) structural measures to reduce the frequency, severity or exposure to the hazard, (2) non-structural measures, such as land-use planning and early warning systems, to reduce the hazard frequency and consequences, and (3) measures to pool and transfer the risks. In a given situation the appropriate system of mitigation measures may be a combination of various types of measures, both structural and non-structural. In the process of choosing mitigation measures for a given landslide risk situation, the role of the geoscientist is normally to propose possible mitigation measures on basis of the risk level and technical feasibility. Social and ethical perspectives are often neglected in this process. However, awareness of the need to consider social as well as ethical issues in the design and management of mitigating landslide risk is rising. There is a growing understanding that technical experts acting alone cannot determine what will be considered the appropriate set of mitigation and prevention measures. Issues such as environment versus development, questions of acceptable risk, who bears the risks and benefits, and who makes the decisions, also need to be addressed. Policymakers and stakeholders engaged in solving environmental risk problems are increasingly recognising that traditional expert-based decision-making processes are insufficient. This paper analyse the process of choosing appropriate mitigation measures to mitigate landslide risk from a social and ethical perspective, considering technical, cultural, economical, environmental and political elements. The paper focus on stakeholder involvement in the decision making process, and shows how making strategies for risk communication is a key for a successful process. The study is supported by case study examples from Norway and Italy. In the Italian case study, three different risk mitigation

  12. Stress-free reference for neutron diffraction measurement of residual stress in butt-welded joints of austenitic stainless steel pipes

    International Nuclear Information System (INIS)

    Maekawa, Akira; Takahashi, Tsuneo; Tsuji, Takashi; Suzuki, Hiroshi; Moriai, Atsushi

    2012-01-01

    Stress-free lattice spacing d_0 has the most influence on reliability of neutron stress measurements made using an angle dispersive method. However, it is hard to evaluate the lattice spacing of welded structures and ductile materials such as stainless steel accurately. In this study, suitable measurement conditions for d_0 of welded pipe joints of austenitic stainless steel were discussed. The d_0 values derived from {311} and {111} reflections, which are often used in austenitic stainless steel for residual stress measurement, were examined. Comparison of the residual strains and stresses evaluated using the obtained d_0 and the finite element analysis showed that the way the d_0 values were chosen affected the measurement accuracy significantly. The stress measurement accuracy was remarkably improved when the {311} reflection was used and the proper d_0 value was chosen in the respective neutron diffraction measurements. For instance, for the axial diffraction measurements using the {311} reflection, it was recommended that only the axial d_0 value of the {311} reflection be used; the measurements using the {111} reflection were less accurate due to the large Young's modulus. Additionally, a lower diffraction angle was judged to be one of the factors leading to a decrease of the strain measurement accuracy. (author)

  13. Residues and Eco-risk Evaluation of Organochlorine Pesticides in Agricultural Soils from Typical Vegetable Produce Areas of Hainan Province, China

    Directory of Open Access Journals (Sweden)

    WU Dong-ming

    2014-08-01

    Full Text Available To determine current levels of organochlorine pesticides(OCPsand assess their sources, ecological risk in agricultural soils from typical vegetable produce areas of Hainan Province, 33 soil samples were collected and detected by the GC method. The results showed that OCPs were found in 90.9%of the collected soil samples and ranged from Not Dedected(NDto 17.37 ng·g-1, with a mean of 2.30 ng·g-1. The DDTs、HCHs、endosulfan and endosulfan sulfate were found over 54%in the collected soil samples. Also, the DDTs were the main compo-nents, and their contribution to the residues of OCPs was over 54.6%. Analysis of the sources of contamination showed that HCHs in the area were mainly derived from lindane. DDTs, which were suspected to have recent application to 18.2%soil, were derived mainly from technical DDTs or dicofol containing DDT impurities. Comparing with various studies and the‘National Environmental Quality Standard for Soils of Chi-na’(GB 15618-1995, OCP pollutions were generally slight in present study, and the ecological risk of HCHs and DDTs residue in agricul-tural soils of Hainan Province was lower.

  14. Pesticide Residues in Food: Attitudes, Beliefs, and Misconceptions among Conventional and Organic Consumers.

    Science.gov (United States)

    Koch, Severine; Epp, Astrid; Lohmann, Mark; Böl, Gaby-Fleur

    2017-12-01

    Pesticide use and pesticide residues in foods have been the subject of controversial public discussions and media coverage in Germany. Against this background, a better understanding of public risk perceptions is needed to promote efficient public health communication. To this end, this study captures the German public's perception of pesticide residues in foods. A representative sample of the population aged 14 years and older (n = 1,004) was surveyed via computer-assisted telephone interviewing on their attitudes and knowledge with regard to pesticide residues. Based on questions regarding their typical consumer behavior, respondents were classified into conventional and organic consumers to identify differences as well as similarities between these two consumer types. As assessed with an open-ended question, both organic and conventional consumers viewed pesticides, chemicals, and toxins as the greatest threats to food quality and safety. Evaluating the risks and benefits of pesticide use, more than two-thirds of organic consumers (70%) rated the risks as greater than the benefits, compared with just over one-half of conventional consumers (53%). Concern about the detection of pesticide residues in the food chain and bodily fluids was significantly higher among organic compared with conventional consumers. Only a minority of respondents was aware that legal limits for pesticide residues (referred to as maximum residue levels) exist, with 69% of organic and 61% of conventional consumers believing that the presence of pesticide residues in foods is generally not permitted. A lack of awareness of maximum residue levels was associated with heightened levels of concern about pesticide residues. Finally, general exposure to media reporting on pesticide residues was associated with more frequent knowledge of legal limits for pesticide residues, whereas actively seeking information on pesticide residues was not. The possible mechanisms underlying these findings are

  15. Study of the location of testing area in residual stress measurement by Moiré interferometry combined with hole-drilling method

    Science.gov (United States)

    Qin, Le; Xie, HuiMin; Zhu, RongHua; Wu, Dan; Che, ZhiGang; Zou, ShiKun

    2014-04-01

    This paper investigates the effect of the location of testing area in residual stress measurement by Moiré interferometry combined with hole-drilling method. The selection of the location of the testing area is analyzed from theory and experiment. In the theoretical study, the factors which affect the surface released radial strain ɛ r were analyzed on the basis of the formulae of the hole-drilling method, and the relations between those factors and ɛ r were established. By combining Moiré interferometry with the hole-drilling method, the residual stress of interference-fit specimen was measured to verify the theoretical analysis. According to the analysis results, the testing area for minimizing the error of strain measurement is determined. Moreover, if the orientation of the maximum principal stress is known, the value of strain will be measured with higher precision by the Moiré interferometry method.

  16. Neutron diffraction measurements of residual stress in additively manufactured stainless steel

    International Nuclear Information System (INIS)

    Brown, D.W.; Bernardin, J.D.; Carpenter, J.S.; Clausen, B.; Spernjak, D.; Thompson, J.M.

    2016-01-01

    Charpy test specimens were additively manufactured (AM) on a single stainless steel plate from a 17–4 class stainless steel using a powder-bed, laser melting technique on an EOS M280 direct metal laser sintering (DMLS) machine. Cross-hatched mesh support structures for the Charpy test specimens were varied in strut width and density to parametrically study their influence on the build stability and accuracy as the DMLS process has been known to generate parts with large amounts of residual stress. Neutron diffraction was used to profile the residual stresses in several of the AM samples before and after the samples were removed from the support structure for the purpose of determining residual stresses. The residual stresses were found to depend very little on the properties of the support structure over the limited range studied here. The largest stress component was in the long direction of each of the samples studied and was roughly 2/3 of the yield stress of the material. The stress field was altered considerably when the specimen was removed from the support structure. It was noted in this study that a single Charpy specimen developed a significant tear between the growth plate and support structure. The presence of the tear in the support structure strongly affected the observed stress field: the asymmetric tear resulted in a significantly asymmetric stress field that propagated through removal of the sample from the base plate. The altered final residual stress state of the sample as well as its observed final shape indicates that the tear initiated during the build and developed without disrupting the fabrication process, suggesting a need for in-situ monitoring.

  17. Neutron diffraction measurements of residual stress in additively manufactured stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W.; Bernardin, J.D.; Carpenter, J.S.; Clausen, B.; Spernjak, D.; Thompson, J.M.

    2016-12-15

    Charpy test specimens were additively manufactured (AM) on a single stainless steel plate from a 17–4 class stainless steel using a powder-bed, laser melting technique on an EOS M280 direct metal laser sintering (DMLS) machine. Cross-hatched mesh support structures for the Charpy test specimens were varied in strut width and density to parametrically study their influence on the build stability and accuracy as the DMLS process has been known to generate parts with large amounts of residual stress. Neutron diffraction was used to profile the residual stresses in several of the AM samples before and after the samples were removed from the support structure for the purpose of determining residual stresses. The residual stresses were found to depend very little on the properties of the support structure over the limited range studied here. The largest stress component was in the long direction of each of the samples studied and was roughly 2/3 of the yield stress of the material. The stress field was altered considerably when the specimen was removed from the support structure. It was noted in this study that a single Charpy specimen developed a significant tear between the growth plate and support structure. The presence of the tear in the support structure strongly affected the observed stress field: the asymmetric tear resulted in a significantly asymmetric stress field that propagated through removal of the sample from the base plate. The altered final residual stress state of the sample as well as its observed final shape indicates that the tear initiated during the build and developed without disrupting the fabrication process, suggesting a need for in-situ monitoring.

  18. Method for evaluationo of the 3D residual stress field from X-ray diffraction measurements on heavy weldments

    International Nuclear Information System (INIS)

    Larsson, L.E.; Sandstroem, R.

    1982-03-01

    A method for evaluation of the three dimensional residual 30 stress distribution in heavy weldmwents has been developed. The evaluation is based on measured stress data at a number of depth levels below the plate surface. The method has been applied to two measurements on heavy weldments of A 553 B steel. Comparison to a previous evaluation shows good agreement. (Authors)

  19. Management of municipal solid waste incineration residues

    International Nuclear Information System (INIS)

    Sabbas, T.; Polettini, A.; Pomi, R.; Astrup, T.; Hjelmar, O.; Mostbauer, P.; Cappai, G.; Magel, G.; Salhofer, S.; Speiser, C.; Heuss-Assbichler, S.; Klein, R.; Lechner, P.

    2003-01-01

    The management of residues from thermal waste treatment is an integral part of waste management systems. The primary goal of managing incineration residues is to prevent any impact on our health or environment caused by unacceptable particulate, gaseous and/or solute emissions. This paper provides insight into the most important measures for putting this requirement into practice. It also offers an overview of the factors and processes affecting these mitigating measures as well as the short- and long-term behavior of residues from thermal waste treatment under different scenarios. General conditions affecting the emission rate of salts and metals are shown as well as factors relevant to mitigating measures or sources of gaseous emissions

  20. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  1. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    1975-10-01

    'Risk of damage' and 'exposure risk' are considered as components of the radiation risk. The influence of the 'exposure risk' on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Basing upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high 'exposure risk'. As a consequence the following recommendations are given for discussion: (a) occupationally exposed persons with small 'exposure risk' should be monitored using only a long-term dosimeter (for instance a thermoluminescence dosimeter), (b) in the case of internal exposure the surface and, if necessary, air contamination should be controlled so strictly that routine measurements of internal contamination need not be performed. (author)

  2. Multi-rate cubature Kalman filter based data fusion method with residual compensation to adapt to sampling rate discrepancy in attitude measurement system.

    Science.gov (United States)

    Guo, Xiaoting; Sun, Changku; Wang, Peng

    2017-08-01

    This paper investigates the multi-rate inertial and vision data fusion problem in nonlinear attitude measurement systems, where the sampling rate of the inertial sensor is much faster than that of the vision sensor. To fully exploit the high frequency inertial data and obtain favorable fusion results, a multi-rate CKF (Cubature Kalman Filter) algorithm with estimated residual compensation is proposed in order to adapt to the problem of sampling rate discrepancy. During inter-sampling of slow observation data, observation noise can be regarded as infinite. The Kalman gain is unknown and approaches zero. The residual is also unknown. Therefore, the filter estimated state cannot be compensated. To obtain compensation at these moments, state error and residual formulas are modified when compared with the observation data available moments. Self-propagation equation of the state error is established to propagate the quantity from the moments with observation to the moments without observation. Besides, a multiplicative adjustment factor is introduced as Kalman gain, which acts on the residual. Then the filter estimated state can be compensated even when there are no visual observation data. The proposed method is tested and verified in a practical setup. Compared with multi-rate CKF without residual compensation and single-rate CKF, a significant improvement is obtained on attitude measurement by using the proposed multi-rate CKF with inter-sampling residual compensation. The experiment results with superior precision and reliability show the effectiveness of the proposed method.

  3. Measuring your radon risk

    International Nuclear Information System (INIS)

    Mackmurdo, R.

    1994-01-01

    In its annual report for 1992/93, the NRPB has warned that tens of thousands of UK employees may be exposed to high levels of radon at work. In addition to those who work underground, employees at risk of radon-induced lung cancer are typically those who spend long periods indoors. This article reviews the implications for all employers especially those in low or unknown levels of radon who resist taking measurements in the belief that by not measuring, they are not liable. (UK)

  4. Will Incremental Hemodialysis Preserve Residual Function and Improve Patient Survival?

    Science.gov (United States)

    Davenport, Andrew

    2015-01-01

    The progressive loss of residual renal function in peritoneal dialysis patients is associated with increased mortality. It has been suggested that incremental dialysis may help preserve residual renal function and improve patient survival. Residual renal function depends upon both patient related and dialysis associated factors. Maintaining patients in an over-hydrated state may be associated with better preservation of residual renal function but any benefit comes with a significant risk of cardiovascular consequences. Notably, it is only observational studies that have reported an association between dialysis patient survival and residual renal function; causality has not been established for dialysis patient survival. The tenuous connections between residual renal function and outcomes and between incremental hemodialysis and residual renal function should temper our enthusiasm for interventions in this area. PMID:25385441

  5. Residual nilpotence and residual solubility of groups

    International Nuclear Information System (INIS)

    Mikhailov, R V

    2005-01-01

    The properties of the residual nilpotence and the residual solubility of groups are studied. The main objects under investigation are the class of residually nilpotent groups such that each central extension of these groups is also residually nilpotent and the class of residually soluble groups such that each Abelian extension of these groups is residually soluble. Various examples of groups not belonging to these classes are constructed by homological methods and methods of the theory of modules over group rings. Several applications of the theory under consideration are presented and problems concerning the residual nilpotence of one-relator groups are considered.

  6. Residual radioactivity of treated green diamonds.

    Science.gov (United States)

    Cassette, Philippe; Notari, Franck; Lépy, Marie-Christine; Caplan, Candice; Pierre, Sylvie; Hainschwang, Thomas; Fritsch, Emmanuel

    2017-08-01

    Treated green diamonds can show residual radioactivity, generally due to immersion in radium salts. We report various activity measurements on two radioactive diamonds. The activity was characterized by alpha and gamma ray spectrometry, and the radon emanation was measured by alpha counting of a frozen source. Even when no residual radium contamination can be identified, measurable alpha and high-energy beta emissions could be detected. The potential health impact of radioactive diamonds and their status with regard to the regulatory policy for radioactive products are discussed. Copyright © 2017. Published by Elsevier Ltd.

  7. Combined Risk Measures: Representation Results and Applications

    NARCIS (Netherlands)

    Göttsche, O.E.

    2014-01-01

    The analysis and interpretation of risk play a crucial role in different areas of modern finance. This includes pricing of financial products, capital allocation and derivation of economic capital. Key to this analysis is the quantification of the risk via risk measures. A promising approach is to

  8. Neutron diffraction measurements for the determination of residual stresses in MMC tensile and fatigue specimens

    DEFF Research Database (Denmark)

    Fiori, F.; Girardin, E.; Giuliani, A.

    2000-01-01

    have been performed at RISO (Roskilde, DK) and HMI-BENSC (Berlin, D), for the determination of residual stress in AA2124 + 17% SiCp and AA359 + 20% SiCp specimens, submitted to tensile and fatigue tests. For each of the investigated samples, the macrostress has been separated from the elastic......, residual stresses are present in both the matrix and the particles microstructure, prior to any macroscopic loading. They vary with the temperature and with the type and level of loading imposed to the material, having a strong influence on the mechanical behaviour of MMCs. Neutron diffraction measurements...... and thermal mismatch microstresses. The results show that, in general, the main contribution to the stress state of both matrix and reinforcement is given by the thermal microstresses, already existing due to heat treatment prior to mechanical tests. (C) 2000 Elsevier Science B.V. All rights reserved....

  9. Residual stresses in multilayer ceramic capacitors: measurement and computation

    NARCIS (Netherlands)

    Toonder, den J.M.J.; Rademaker, C.W.; Hu, C.L.

    2003-01-01

    In this paper, we present a combined experimental and computational study of the thermomechanical reliability of multilayer ceramic capacitors (MLCC's). We focus on residual stresses introduced into the components during the cooling down step of the sintering process. The technique of

  10. Measuring Risk When Expected Losses Are Unbounded

    Directory of Open Access Journals (Sweden)

    Alejandro Balbás

    2014-09-01

    Full Text Available This paper proposes a new method to introduce coherent risk measures for risks with infinite expectation, such as those characterized by some Pareto distributions. Extensions of the conditional value at risk, the weighted conditional value at risk and other examples are given. Actuarial applications are analyzed, such as extensions of the expected value premium principle when expected losses are unbounded.

  11. RISK LOAN PORTFOLIO OPTIMIZATION MODEL BASED ON CVAR RISK MEASURE

    Directory of Open Access Journals (Sweden)

    Ming-Chang LEE

    2015-07-01

    Full Text Available In order to achieve commercial banks liquidity, safety and profitability objective requirements, loan portfolio risk analysis based optimization decisions are rational allocation of assets.  The risk analysis and asset allocation are the key technology of banking and risk management.  The aim of this paper, build a loan portfolio optimization model based on risk analysis.  Loan portfolio rate of return by using Value-at-Risk (VaR and Conditional Value-at-Risk (CVaR constraint optimization decision model reflects the bank's risk tolerance, and the potential loss of direct control of the bank.  In this paper, it analyze a general risk management model applied to portfolio problems with VaR and CVaR risk measures by using Using the Lagrangian Algorithm.  This paper solves the highly difficult problem by matrix operation method.  Therefore, the combination of this paper is easy understanding the portfolio problems with VaR and CVaR risk model is a hyperbola in mean-standard deviation space.  It is easy calculation in proposed method.

  12. Measurement of total risk of spontaneous abortion: the virtue of conditional risk estimation

    DEFF Research Database (Denmark)

    Modvig, J; Schmidt, L; Damsgaard, M T

    1990-01-01

    The concepts, methods, and problems of measuring spontaneous abortion risk are reviewed. The problems touched on include the process of pregnancy verification, the changes in risk by gestational age and maternal age, and the presence of induced abortions. Methods used in studies of spontaneous...... abortion risk include biochemical assays as well as life table technique, although the latter appears in two different forms. The consequences of using either of these are discussed. It is concluded that no study design so far is appropriate for measuring the total risk of spontaneous abortion from early...... conception to the end of the 27th week. It is proposed that pregnancy may be considered to consist of two or three specific periods and that different study designs should concentrate on measuring the conditional risk within each period. A careful estimate using this principle leads to an estimate of total...

  13. Acid transformation of bauxite residue: Conversion of its alkaline characteristics

    OpenAIRE

    Kong, X.; Li, M.; Xue, S.; Hartley, W.; Chen, C.; Wu, C.; Li, X.; Li, Y.

    2016-01-01

    Bauxite residue (BR) is a highly alkaline solid hazardous waste produced from bauxite processing for alumina production. Alkaline transformation appears to reduce the environmental risk of bauxite residue disposal areas (BRDAs) whilst potentially providing opportunities for the sustainable reuse and on-going management of BR. Mineral acids, a novel citric acid and a hybrid combination of acid-gypsum treatments were investigated for their potential to reduce residue pH and total alkalinity and...

  14. Rapid measurement of residual dipolar couplings for fast fold elucidation of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Rasia, Rodolfo M. [Jean-Pierre Ebel CNRS/CEA/UJF, Institut de Biologie Structurale (France); Lescop, Ewen [CNRS, Institut de Chimie des Substances Naturelles (France); Palatnik, Javier F. [Universidad Nacional de Rosario, Instituto de Biologia Molecular y Celular de Rosario, Facultad de Ciencias Bioquimicas y Farmaceuticas (Argentina); Boisbouvier, Jerome, E-mail: jerome.boisbouvier@ibs.fr; Brutscher, Bernhard, E-mail: Bernhard.brutscher@ibs.fr [Jean-Pierre Ebel CNRS/CEA/UJF, Institut de Biologie Structurale (France)

    2011-11-15

    It has been demonstrated that protein folds can be determined using appropriate computational protocols with NMR chemical shifts as the sole source of experimental restraints. While such approaches are very promising they still suffer from low convergence resulting in long computation times to achieve accurate results. Here we present a suite of time- and sensitivity optimized NMR experiments for rapid measurement of up to six RDCs per residue. Including such an RDC data set, measured in less than 24 h on a single aligned protein sample, greatly improves convergence of the Rosetta-NMR protocol, allowing for overnight fold calculation of small proteins. We demonstrate the performance of our fast fold calculation approach for ubiquitin as a test case, and for two RNA-binding domains of the plant protein HYL1. Structure calculations based on simulated RDC data highlight the importance of an accurate and precise set of several complementary RDCs as additional input restraints for high-quality de novo structure determination.

  15. Geometry of X-ray based measurement of residual strain at desired penetration depth

    Energy Technology Data Exchange (ETDEWEB)

    Morawiec, A. [Polish Academy of Sciences, Institute of Metallurgy and Materials Science, Krakow (Poland)

    2017-10-15

    X-ray based measurement of residual lattice strains at chosen penetration depth is one of the methods for investigating strain inhomogeneities in near-surface layers of polycrystalline materials. The measurement relies on determining shifts of Bragg peaks for various directions of the scattering vector with respect to the specimen. At each of these directions, to reach a given the penetration depth, a proper specimen orientation is required. The task of determining such orientations, albeit elementary, is quite intricate. The existing literature describes only partial solutions with unspecified domains of application, which fail if applied to beyond the domains. Therefore, geometric aspects of the measurement are analyzed in details. Explicit bounds on measurement parameters are given. The equation fundamental for the procedure is solved with respect to specimen orientations. For a given direction of the scattering vector, there are generally four different specimen orientations leading to the same penetration depth. This simple fact (overlooked in previous analyses) can be used for improving reliability of measurement results. Analytical formulas for goniometer angles representing these orientations are provided. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Validation of a Residual Stress Measurement Method by Swept High-Frequency Eddy Currents

    International Nuclear Information System (INIS)

    Lee, C.; Shen, Y.; Lo, C. C. H.; Nakagawa, N.

    2007-01-01

    This paper reports on a swept high-frequency eddy current (SHFEC) measurement method developed for electromagnetic nondestructive characterization of residual stresses in shot peened aerospace materials. In this approach, we regard shot-peened surfaces as modified surface layers of varying conductivity, and determine the conductivity deviation profile by inversion of the SHFEC data. The SHFEC measurement system consists of a pair of closely matched printed-circuit-board coils driven by laboratory instrument under software control. This provides improved sensitivity and high frequency performance compared to conventional coils, so that swept frequency EC measurements up to 50 MHz can be made to achieve the smallest skin depth of 80 μm for nickel-based superalloys. We devised a conductivity profile inversion procedure based on the laterally uniform multi-layer theory of Cheng, Dodd and Deeds. The main contribution of this paper is the methodology validation. Namely, the forward and inverse models were validated against measurements on artificial layer specimens consisting of metal films with different conductivities placed on a metallic substrate. The inversion determined the film conductivities which were found to agree with those measured using the direct current potential drop (DCPD) method

  17. Validation of a Residual Stress Measurement Method by Swept High-Frequency Eddy Currents

    Science.gov (United States)

    Lee, C.; Shen, Y.; Lo, C. C. H.; Nakagawa, N.

    2007-03-01

    This paper reports on a swept high-frequency eddy current (SHFEC) measurement method developed for electromagnetic nondestructive characterization of residual stresses in shot peened aerospace materials. In this approach, we regard shot-peened surfaces as modified surface layers of varying conductivity, and determine the conductivity deviation profile by inversion of the SHFEC data. The SHFEC measurement system consists of a pair of closely matched printed-circuit-board coils driven by laboratory instrument under software control. This provides improved sensitivity and high frequency performance compared to conventional coils, so that swept frequency EC measurements up to 50 MHz can be made to achieve the smallest skin depth of 80 μm for nickel-based superalloys. We devised a conductivity profile inversion procedure based on the laterally uniform multi-layer theory of Cheng, Dodd and Deeds. The main contribution of this paper is the methodology validation. Namely, the forward and inverse models were validated against measurements on artificial layer specimens consisting of metal films with different conductivities placed on a metallic substrate. The inversion determined the film conductivities which were found to agree with those measured using the direct current potential drop (DCPD) method.

  18. Residual pyrethroids in fresh horticultural products in Sonora, Mexico.

    Science.gov (United States)

    Aldana-Madrid, Maria L; Valenzuela-Quintanar, Ana I; Silveira-Gramont, Maria I; Rodríguez-Olibarría, Guillermo; Grajeda-Cota, Patricia; Zuno-Floriano, Fabiola G; Miller, Marion G

    2011-10-01

    This study was conducted to evaluate the presence of cyhialothrin, cyfluthrin, cypermethrin, fenvalerate, and deltamethrin in vegetables produced and consumed in Sonora, Mexico. A total of 345 samples were collected from cluster sampling of markets and fields. Approximately 9% of the samples tested positive for pyrethroids (residue range 0.004-0.573 mg kg(-1)). Based on the results, the potential toxicological risk of human exposure to the pyrethroid insecticides measured in vegetables appears to be minimal, with the estimated exposure being 1,000 times lower than admissible levels. © Springer Science+Business Media, LLC 2011

  19. Farmers' Risk Preferences in Rural China: Measurements and Determinants.

    Science.gov (United States)

    Jin, Jianjun; He, Rui; Gong, Haozhou; Xu, Xia; He, Chunyang

    2017-06-30

    This study measures farmers' risk attitudes in rural China using a survey instrument and a complementary experiment conducted in the field with the same sample of subjects. Using a question asking people about their willingness to take risks "in general", we found that the average response of our sample is slightly risk averse. Farmers' exogenous factors (age, gender, and height) and self-reported happiness have a significant impact on farmers' willingness to take risks. The experiment results show that approximately 44% of farmers in the study area are risk averse. We compare farmers' self-reported measures of risk preferences derived from the survey instrument to preferences elicited through the experimental task. Results show that answers to the general risk attitude question in the survey can predict farmers' behaviors in the experiment to a statistically significant degree. This paper can contribute to the empirical literature on comparing local farmers' risk attitudes across different risk preference measurement methods in the developing world.

  20. Radiation risk estimation based on measurement error models

    CERN Document Server

    Masiuk, Sergii; Shklyar, Sergiy; Chepurny, Mykola; Likhtarov, Illya

    2017-01-01

    This monograph discusses statistics and risk estimates applied to radiation damage under the presence of measurement errors. The first part covers nonlinear measurement error models, with a particular emphasis on efficiency of regression parameter estimators. In the second part, risk estimation in models with measurement errors is considered. Efficiency of the methods presented is verified using data from radio-epidemiological studies.

  1. Entropy coherent and entropy convex measures of risk

    NARCIS (Netherlands)

    Laeven, Roger; Stadje, M.A.

    2010-01-01

    We introduce entropy coherent and entropy convex measures of risk and prove a collection of axiomatic characterization and duality results. We show in particular that entropy coherent and entropy convex measures of risk emerge as negative certainty equivalents in (the regular and a generalized

  2. Protein structure based prediction of catalytic residues.

    Science.gov (United States)

    Fajardo, J Eduardo; Fiser, Andras

    2013-02-22

    Worldwide structural genomics projects continue to release new protein structures at an unprecedented pace, so far nearly 6000, but only about 60% of these proteins have any sort of functional annotation. We explored a range of features that can be used for the prediction of functional residues given a known three-dimensional structure. These features include various centrality measures of nodes in graphs of interacting residues: closeness, betweenness and page-rank centrality. We also analyzed the distance of functional amino acids to the general center of mass (GCM) of the structure, relative solvent accessibility (RSA), and the use of relative entropy as a measure of sequence conservation. From the selected features, neural networks were trained to identify catalytic residues. We found that using distance to the GCM together with amino acid type provide a good discriminant function, when combined independently with sequence conservation. Using an independent test set of 29 annotated protein structures, the method returned 411 of the initial 9262 residues as the most likely to be involved in function. The output 411 residues contain 70 of the annotated 111 catalytic residues. This represents an approximately 14-fold enrichment of catalytic residues on the entire input set (corresponding to a sensitivity of 63% and a precision of 17%), a performance competitive with that of other state-of-the-art methods. We found that several of the graph based measures utilize the same underlying feature of protein structures, which can be simply and more effectively captured with the distance to GCM definition. This also has the added the advantage of simplicity and easy implementation. Meanwhile sequence conservation remains by far the most influential feature in identifying functional residues. We also found that due the rapid changes in size and composition of sequence databases, conservation calculations must be recalibrated for specific reference databases.

  3. Profit and Risk Measures in Oil Production Optimization

    DEFF Research Database (Denmark)

    Capolei, Andrea; Foss, Bjarne; Jørgensen, John Bagterp

    2015-01-01

    In oil production optimization, we usually aim to maximize a deterministic scalar performance index such as the profit over the expected reservoir lifespan. However, when uncertainty in the parameters is considered, the profit results in a random variable that can assume a range of values dependi...... pro and cons for each of them. Finally, among the presented risk measures, we identify two of them as appropriate risk measures when minimizing the risk....

  4. Joint measurement of risk aversion, prudence, and temperance

    NARCIS (Netherlands)

    Ebert, S.; Wiesen, D.

    Risk aversion—but also the higher-order risk preferences of prudence and temperance—are fundamental concepts in the study of economic decision making. We propose a method to jointly measure the intensity of risk aversion, prudence, and temperance. Our theoretical approach is to define risk

  5. On risk measures and decisions in insurance and finance

    NARCIS (Netherlands)

    Goovaerts, M.J.; Kaas, R.; Laeven, R.J.A.

    2009-01-01

    In this paper, we argue that a distinction exists between risk measures and decision principles. Though both are functionals assigning a real number to a random variable, we think there is a hierarchy between the two concepts. Risk measures operate on the first "level", quantifying the risk in the

  6. Measurement of residual CO2 saturation at a geological storage site using hydraulic tests

    Science.gov (United States)

    Rötting, T. S.; Martinez-Landa, L.; Carrera, J.; Russian, A.; Dentz, M.; Cubillo, B.

    2012-12-01

    Estimating long term capillary trapping of CO2 in aquifers remains a key challenge for CO2 storage. Zhang et al. (2011) proposed a combination of thermal, tracer, and hydraulic experiments to estimate the amount of CO2 trapped in the formation after a CO2 push and pull test. Of these three types of experiments, hydraulic tests are the simplest to perform and possibly the most informative. However, their potential has not yet been fully exploited. Here, a methodology is presented to interpret these tests and analyze which parameters can be estimated. Numerical and analytical solutions are used to simulate a continuous injection in a porous medium where residual CO2 has caused a reduction in hydraulic conductivity and an increase in storativity over a finite thickness (a few meters) skin around the injection well. The model results are interpreted using conventional pressure build-up and diagnostic plots (a plot of the drawdown s and the logarithmic derivative d s / d ln t of the drawdown as a function of time). The methodology is applied using the hydraulic parameters estimated for the Hontomin site (Northern Spain) where a Technology Demonstration Plant (TDP) for geological CO2 storage is planned to be set up. The reduction of hydraulic conductivity causes an increase in observed drawdowns, the increased storativity in the CO2 zone causes a delay in the drawdown curve with respect to the reference curve measured before CO2 injection. The duration (characteristic time) of these effects can be used to estimate the radius of the CO2 zone. The effects of reduced permeability and increased storativity are well separated from wellbore storage and natural formation responses, even if the CO2-brine interface is inclined (i.e. the CO2 forms a cone around the well). We find that both skin hydraulic conductivity and storativity (and thus residual CO2 saturation) can be obtained from the water injection test provided that water flow rate is carefully controlled and head build

  7. Radon in indoor air. Health risk, measurement methods and remedial measures

    International Nuclear Information System (INIS)

    Strand, T.

    1996-02-01

    Radon in indoor air is the main source of ionizing radiation in Norway. The booklet contains a presentation of radon sources, measurement methods, indoor radon concentrations, action levels, health risk and remedial measures

  8. Methods for measuring risk-aversion: problems and solutions

    International Nuclear Information System (INIS)

    Thomas, P J

    2013-01-01

    Risk-aversion is a fundamental parameter determining how humans act when required to operate in situations of risk. Its general applicability has been discussed in a companion presentation, and this paper examines methods that have been used in the past to measure it and their attendant problems. It needs to be borne in mind that risk-aversion varies with the size of the possible loss, growing strongly as the possible loss becomes comparable with the decision maker's assets. Hence measuring risk-aversion when the potential loss or gain is small will produce values close to the risk-neutral value of zero, irrespective of who the decision maker is. It will also be shown how the generally accepted practice of basing a measurement on the results of a three-term Taylor series will estimate a limiting value, minimum or maximum, rather than the value utilised in the decision. A solution is to match the correct utility function to the results instead

  9. Methods for measuring risk-aversion: problems and solutions

    Science.gov (United States)

    Thomas, P. J.

    2013-09-01

    Risk-aversion is a fundamental parameter determining how humans act when required to operate in situations of risk. Its general applicability has been discussed in a companion presentation, and this paper examines methods that have been used in the past to measure it and their attendant problems. It needs to be borne in mind that risk-aversion varies with the size of the possible loss, growing strongly as the possible loss becomes comparable with the decision maker's assets. Hence measuring risk-aversion when the potential loss or gain is small will produce values close to the risk-neutral value of zero, irrespective of who the decision maker is. It will also be shown how the generally accepted practice of basing a measurement on the results of a three-term Taylor series will estimate a limiting value, minimum or maximum, rather than the value utilised in the decision. A solution is to match the correct utility function to the results instead.

  10. Neutron Diffraction Residual Strain Tensor Measurements Within The Phase IA Weld Mock-up Plate P-5

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Camden R [ORNL

    2011-09-01

    Oak Ridge National Laboratory (ORNL) has worked with NRC and EPRI to apply neutron and X-ray diffraction methods to characterize the residual stresses in a number of dissimilar metal weld mockups and samples. The design of the Phase IA specimens aimed to enable stress measurements by several methods and computational modeling of the weld residual stresses. The partial groove in the 304L stainless steel plate was filled with weld beads of Alloy 82. A summary of the weld conditions for each plate is provided in Table 1. The plates were constrained along the long edges during and after welding by bolts with spring-loaded washers attached to the 1-inch thick Al backing plate. The purpose was to avoid stress relief due to bending of the welded stainless steel plate. The neutron diffraction method was one of the methods selected by EPRI for non-destructive through thickness strain and stress measurement. Four different plates (P-3 to P-6) were studied by neutron diffraction strain mapping, representing four different welding conditions. Through thickness neutron diffraction strain mappings at NRSF2 for the four plates and associated strain-free d-zero specimens involved measurement along seven lines across the weld and at six to seven depths. The mountings of each plate for neutron diffraction measurements were such that the diffraction vector was parallel to each of the three primary orthogonal directions of the plate: two in-plane directions, longitudinal and transverse, and the direction normal to the plate (shown in left figure within Table 1). From the three orthogonal strains for each location, the residual stresses along the three plate directions were calculated. The principal axes of the strain and stress tensors, however, need not necessarily align with the plate coordinate system. To explore this, plate P-5 was selected for examination of the possibility that the principal axes of strain are not along the sample coordinate system axes. If adequate data could

  11. Progress in stabilization of plutonium and residues since DNFSB recommendation 94-1

    International Nuclear Information System (INIS)

    Ball, J.M.; Dustin, D.F.

    1998-01-01

    There are approximately 100 metric tons of residues at the Rocky Flats Environmental Technology Site containing approximately 3 metric tons of plutonium. The residues are byproducts of past plutonium operations incinerator ash; pyrochemical salts; graphite; sand, slag, and crucible; and miscellaneous forms of combustibles, glass, metal, and sludges. In September 1993, a report was released (Reference 1) which identified concerns with the chemical stability of the residues and with the integrity of packaging. In May 1997, the Defense Nuclear Facility Safety Board published recommendation 94-1 citing a concern for the residue stability and requiring that the possibly unstable residues be processed within 3 years and all others within 5 years. A risk categorization scheme was developed which assigned a numerical risk to each residue type based on the probability and consequence of occurrence of failures associated with the hazards identified. The residues were ranked for priority of stabilization actions. Urgent concerns were resolved. All residue drums were vented to eliminate the potential for hydrogen and other explosive gas accumulation. Leaded rubber gloves and ion exchange resins were washed to eliminate the explosion potential. An aggressive characterization program was implemented to search for any additional safety or environmental concerns and to gain more definitive information concerning the choice of processes for stabilization and disposition of the residues. This paper provides background on the safety issues and summarizes recent characterization data. The residue processing and disposition plans, including schedule and cost, are also summarized in the paper. Finally, the paper addresses initiatives undertaken by Safe Sites of Colorado to accelerate the residue program

  12. An ecotoxic risk assessment of residue materials produced by the plasma pyrolysis/vitrification (PP/V) process.

    Science.gov (United States)

    Lapa, N; Santos, Oliveira J F; Camacho, S L; Circeo, L J

    2002-01-01

    Plasma is the fourth state of matter, following the three states of solid, liquid and gas. Experience has amply demonstrated that solids exposed to the oxygen-deficient plasma flame are converted to liquid, and liquid exposed to the same flame is converted to gas. A low amount of vitrified solid residue material usually remains at the end of this process. Plasma pyrolysis/vitrification (PP/V) has been demonstrated as a safe, efficient, cost-effective technology for the treatment of wastes, including hazardous wastes. Besides the low amounts of gaseous byproducts that PP/V produces, the solid vitrified residue presents a low leachability of pollutants. Studies have been performed in many countries in order to assess the leachability of chemical substances. But from the results of identified studies, none has reported results on the ecotoxicological properties of the leachates. The aim of this study was to contribute to the assessment of ecotoxic risk of four different vitrified materials. Vitrified samples of contaminated soils, municipal solid wastes, and incinerator bottom ashes were submitted to the European leaching pre-standard test number prEN 12457-2. The leachates were analyzed for 22 chemical parameters. The biological characterization comprised the assessment of bioluminescence inhibition of Photobacterium phosphoreum bacterium, growth inhibition of Pseudokirchneriella subcapitata algae and the germination inhibition of Lactuca sativa vegetable. The chemical and ecotoxicological results were analyzed according to the French proposal of Criteria on the Evaluation Methods of Waste Toxicity (CEMWT) and a Toxicity Classification System (TCS). The chemical and ecotoxicological results indicated a low leachability of pollutants and a low toxicity level of leachates. All samples studied were as below the TCS class 1 level (no significant toxicity observed) and as non-ecotoxic for CEMWT. Therefore, the environmental ecotoxic risk of the analyzed vitrified samples

  13. Risk assessments for exposure of deployed military personnel to insecticides and personal protective measures used for disease-vector management.

    Science.gov (United States)

    Macedo, Paula A; Peterson, Robert K D; Davis, Ryan S

    2007-10-01

    Infectious diseases are problematic for deployed military forces throughout the world, and, historically, more military service days have been lost to insect-vectored diseases than to combat. Because of the limitations in efficacy and availability of both vaccines and therapeutic drugs, vector management often is the best tool that military personnel have against most vector-borne pathogens. However, the use of insecticides may raise concerns about the safety of their effects on the health of the military personnel exposed to them. Therefore, our objective was to use risk assessment methodologies to evaluate health risks to deployed U.S. military personnel from vector management tactics. Our conservative tier-1, quantitative risk assessment focused on acute, subchronic, and chronic exposures and cancer risks to military personnel after insecticide application and use of personal protective measures in different scenarios. Exposures were estimated for every scenario, chemical, and pathway. Acute, subchronic, and chronic risks were assessed using a margin of exposure (MOE) approach. Our MOE was the ratio of a no-observed-adverse-effect level (NOAEL) to an estimated exposure. MOEs were greater than the levels of concern (LOCs) for all surface residual and indoor space spraying exposures, except acute dermal exposure to lambda-cyhalothrin. MOEs were greater than the LOCs for all chemicals in the truck-mounted ultra-low-volume (ULV) exposure scenario. The aggregate cancer risk for permethrin exceeded 1 x 10(-6), but more realistic exposure refinements would reduce the cancer risk below that value. Overall, results indicate that health risks from exposures to insecticides and personal protective measures used by military personnel are low.

  14. Risk measures on networks and expected utility

    International Nuclear Information System (INIS)

    Cerqueti, Roy; Lupi, Claudio

    2016-01-01

    In reliability theory projects are usually evaluated in terms of their riskiness, and often decision under risk is intended as the one-shot-type binary choice of accepting or not accepting the risk. In this paper we elaborate on the concept of risk acceptance, and propose a theoretical framework based on network theory. In doing this, we deal with system reliability, where the interconnections among the random quantities involved in the decision process are explicitly taken into account. Furthermore, we explore the conditions to be satisfied for risk-acceptance criteria to be consistent with the axiomatization of standard expected utility theory within the network framework. In accordance with existing literature, we show that a risk evaluation criterion can be meaningful even if it is not consistent with the standard axiomatization of expected utility, once this is suitably reinterpreted in the light of networks. Finally, we provide some illustrative examples. - Highlights: • We discuss risk acceptance and theoretically develop this theme on the basis of network theory. • We propose an original framework for describing the algebraic structure of the set of the networks, when they are viewed as risks. • We introduce the risk measures on networks, which induce total orders on the set of networks. • We state conditions on the risk measures on networks to let the induced risk-acceptance criterion be consistent with a new formulation of the expected utility theory.

  15. Flood risk management in Flanders: from flood risk objectives to appropriate measures through state assessment

    Directory of Open Access Journals (Sweden)

    Verbeke Sven

    2016-01-01

    Full Text Available In compliance with the EU Flood Directive to reduce flood risk, flood risk management objectives are indispensable for the delineation of necessary measures. In Flanders, flood risk management objectives are part of the environmental objectives which are judicially integrated by the Decree on Integrated Water Policy. Appropriate objectives were derived by supporting studies and extensive consultation on a local, regional and policy level. Under a general flood risk objective sub-objectives are formulated for different aspects: water management and safety, shipping, ecology, and water supply. By developing a risk matrix, it is possible to assess the current state of flood risk and to judge where action is needed to decrease the risk. Three different states of flood risk are distinguished: a acceptable risk, where no action is needed, b intermediate risk where the risk should be reduced by cost efficient actions, and c unacceptable risk, where action is necessary. For each particular aspect, the severity of the consequences of flooding is assessed by quantifiable indicators, such as economic risk, people at risk and ecological flood tolerance. The framework also allows evaluating the effects of the implemented measures and the autonomous development such as climate change and land use change. This approach gives a quantifiable assessment of state, and enables a prioritization of flood risk measures for the reduction of flood risk in a cost efficient and sustainable way.

  16. Residual determination and risk assessment of buprofezin in plum (Prunus domestica) grown in open-field conditions following the application of three different formulations.

    Science.gov (United States)

    Kabir, Md Humayun; Abd El-Aty, A M; Kim, Sung-Woo; Lee, Han Sol; Rahman, Md Musfiqur; Lee, Young-Jun; Chung, Hyung Suk; Lieu, Truong; Choi, Jeong-Heui; Shin, Ho-Chul; Im, Geon-Jae; Hong, Su Myeong; Shim, Jae-Han

    2016-11-01

    This study was conducted to characterize the residual level and perform a risk assessment on buprofezin formulated as an emulsifiable concentrate, wettable powder, and suspension concentrate over various treatment schedules in plum (Prunus domestica). The samples were extracted with an AOAC quick, easy, cheap, effective, rugged, and safe, 'QuEChERS', method after major modifications. As intrinsic interferences were observed in blank plum samples following dispersive-solid phase extraction (consisting of primary secondary amine and C 18 sorbents), amino cartridges were used for solid-phase extraction. Analysis was carried out using liquid chromatography with diode array detection and confirmed by liquid chromatography-tandem mass spectrometry. The method showed excellent linearity with determination coefficient (R 2  = 1) and satisfactory recoveries (at two spiking levels, 0.5 and 2.5 mg/kg) between 90.98 and 94.74% with relative standard deviation (RSD) ≤8%. The limit of quantification (0.05 mg/kg) was considerably lower than the maximum residue limit (2 mg/kg) set by the Codex Alimentarius. Absolute residue levels for emulsifiable concentrates were highest, perhaps owing to the dilution rate and adjuvant. Notably, all formulation residues were lower than the maximum residue limit, and safety data proved that the fruits are safe for consumers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Legionella species colonization in cooling towers: risk factors and assessment of control measures.

    Science.gov (United States)

    Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2010-02-01

    Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and

  18. Solow Residuals Without Capital Stocks

    DEFF Research Database (Denmark)

    Burda, Michael C.; Severgnini, Battista

    2014-01-01

    We use synthetic data generated by a prototypical stochastic growth model to assess the accuracy of the Solow residual (Solow, 1957) as a measure of total factor productivity (TFP) growth when the capital stock in use is measured with error. We propose two alternative measurements based on curren...

  19. Emissions of N2O and CH4 from agricultural soils amended with two types of biogas residues

    International Nuclear Information System (INIS)

    Odlare, M.; Abubaker, J.; Lindmark, J.; Pell, M.; Thorin, E.; Nehrenheim, E.

    2012-01-01

    Biogas residues contain valuable plant nutrients, important to the crops and also to soil microorganisms. However, application of these materials to the soils may contribute to the emission of greenhouse gases (GHG) causing global warming and climate change. In the present study, incubation experiment was carried out, where the emission rates of N 2 O and CH 4 were measured after amending two soils with two types of biogas residues: (1) a regular residue from a large scale biogas plant (BR) and (2) a residue from an ultra-filtration membrane unit connected to a pilot-scale biogas plant (BRMF). The emissions of N 2 O and CH 4 were measured at two occasions: at 24 h and at 7 days after residue amendment, respectively. Amendment with filtered biogas residues (BRMF) led to an increase in N 2 O emissions with about 6–23 times in organic and clay soil, respectively, in comparison to unfiltered biogas residues (BR). Methane emission was detected in small amounts when filtered biogas residue was added to the soil. Amendment of unfiltered biogas to the organic soil resulted in net consumption. In conclusion, fertilization with BRMF can be combined with risk of an increase N 2 O emission, especially when applied to organic soils. However, in order to transfer these results to real life agriculture, large scale field studies need to be carried out. -- Highlights: ► Membrane filtration of biogas process water is a promising method. ► Fertilization of biogas residue may increase the N 2 O emission from soil. ► Organic soils produced higher emissions than clay soils.

  20. Measuring Risk Perception in Later Life: The Perceived Risk Scale.

    Science.gov (United States)

    Lifshitz, Rinat; Nimrod, Galit; Bachner, Yaacov G

    2016-11-01

    Risk perception is a subjective assessment of the actual or potential threat to one's life or, more broadly, to one's psychological well-being. Given the various risks associated with later life, a valid and reliable integrative screening tool for assessing risk perception among the elderly is warranted. The study examined the psychometric properties and factor structure of a new integrative risk perception instrument, the Perceived Risk Scale. This eight-item measure refers to various risks simultaneously, including terror, health issues, traffic accidents, violence, and financial loss, and was developed specifically for older adults. An online survey was conducted with 306 participants aged 50 years and older. The scale was examined using exploratory factor analysis and concurrent validity testing. Factor analysis revealed a two-factor structure: later-life risks and terror risks A high percentage of explained variance, as well as internal consistency, was found for the entire scale and for both factors. Concurrent validity was supported by significant positive associations with participants' depression and negative correlations with their life satisfaction. These findings suggest that the Perceived Risk Scale is internally reliable, valid, and appropriate for evaluating risk perception in later life. The scale's potential applications are discussed. © The Author(s) 2016.

  1. Evaluation of pesticide residues in fruits and vegetables from Algeria.

    Science.gov (United States)

    Mebdoua, Samira; Lazali, Mohamed; Ounane, Sidi Mohamed; Tellah, Sihem; Nabi, Fahima; Ounane, Ghania

    2017-06-01

    A total of 160 samples of 13 types of fresh fruits and vegetables from domestic production and import were analysed to detect the presence of pesticide residues. Analysis was performed by multi-residual extraction followed by gas chromatography-mass spectrometry. In 42.5% of the tested samples, no residues were found and 12.5% of samples contained pesticide residues above maximum residue limits. Risk assessment for long-term exposure was done for all pesticides detected in this study. Except chlorpyrifos and lambda-cyhalothrin, exposure to pesticides from vegetables and fruits was below 1% of the acceptable daily intake. Short-term exposure assessment revealed that in seven pesticide/commodity combinations, including three pesticides (chlorpyrifos, deltamethrin and lambda-cyhalothrin), the acute reference dose had been exceeded.

  2. Predictability of cardiovascular risks by psychological measures

    Czech Academy of Sciences Publication Activity Database

    Šolcová, Iva; Kebza, V.

    2008-01-01

    Roč. 23, č. 1 (2008), s. 241-241 ISSN 0887-0446 R&D Projects: GA ČR GA406/06/0747 Institutional research plan: CEZ:AV0Z70250504 Keywords : CVD risks * psychological measures * physiological risks Subject RIV: AN - Psychology

  3. Soil water evaporation and crop residues

    Science.gov (United States)

    Crop residues have value when left in the field and also when removed from the field and sold as a commodity. Reducing soil water evaporation (E) is one of the benefits of leaving crop residues in place. E was measured beneath a corn canopy at the soil suface with nearly full coverage by corn stover...

  4. Alternative measures of risk of extreme events in decision trees

    International Nuclear Information System (INIS)

    Frohwein, H.I.; Lambert, J.H.; Haimes, Y.Y.

    1999-01-01

    A need for a methodology to control the extreme events, defined as low-probability, high-consequence incidents, in sequential decisions is identified. A variety of alternative and complementary measures of the risk of extreme events are examined for their usability as objective functions in sequential decisions, represented as single- or multiple-objective decision trees. Earlier work had addressed difficulties, related to non-separability, with the minimization of some measures of the risk of extreme events in sequential decisions. In an extension of these results, it is shown how some non-separable measures of the risk of extreme events can be interpreted in terms of separable constituents of risk, thereby enabling a wider class of measures of the risk of extreme events to be handled in a straightforward manner in a decision tree. Also for extreme events, results are given to enable minimax- and Hurwicz-criterion analyses in decision trees. An example demonstrates the incorporation of different measures of the risk of extreme events in a multi-objective decision tree. Conceptual formulations for optimizing non-separable measures of the risk of extreme events are identified as an important area for future investigation

  5. Quadratic residues and non-residues selected topics

    CERN Document Server

    Wright, Steve

    2016-01-01

    This book offers an account of the classical theory of quadratic residues and non-residues with the goal of using that theory as a lens through which to view the development of some of the fundamental methods employed in modern elementary, algebraic, and analytic number theory. The first three chapters present some basic facts and the history of quadratic residues and non-residues and discuss various proofs of the Law of Quadratic Reciprosity in depth, with an emphasis on the six proofs that Gauss published. The remaining seven chapters explore some interesting applications of the Law of Quadratic Reciprocity, prove some results concerning the distribution and arithmetic structure of quadratic residues and non-residues, provide a detailed proof of Dirichlet’s Class-Number Formula, and discuss the question of whether quadratic residues are randomly distributed. The text is a valuable resource for graduate and advanced undergraduate students as well as for mathematicians interested in number theory.

  6. A Simple Surface-Enhanced Raman Spectroscopic Method for on-Site Screening of Tetracycline Residue in Whole Milk

    Directory of Open Access Journals (Sweden)

    Sagar Dhakal

    2018-02-01

    Full Text Available Therapeutic and subtherapeutic use of veterinary drugs has increased the risk of residue contamination in animal food products. Antibiotics such as tetracycline are used for mastitis treatment of lactating cows. Milk expressed from treated cows before the withdrawal period has elapsed may contain tetracycline residue. This study developed a simple surface-enhanced Raman spectroscopic (SERS method for on-site screening of tetracycline residue in milk and water. Six batches of silver colloid nanoparticles were prepared for surface enhancement measurement. Milk-tetracycline and water-tetracycline solutions were prepared at seven concentration levels (1000, 500, 100, 10, 1, 0.1, and 0.01 ppm and spiked with silver colloid nanoparticles. A 785 nm Raman spectroscopic system was used for spectral measurement. Tetracycline vibrational modes were observed at 1285, 1317 and 1632 cm−1 in water-tetracycline solutions and 1322 and 1621 cm−1 (shifted from 1317 and 1632 cm−1, respectively in milk-tetracycline solutions. Tetracycline residue concentration as low as 0.01 ppm was detected in both the solutions. The peak intensities at 1285 and 1322 cm−1 were used to estimate the tetracycline concentrations in water and milk with correlation coefficients of 0.92 for water and 0.88 for milk. Results indicate that this SERS method is a potential tool that can be used on-site at field production for qualitative and quantitative detection of tetracycline residues.

  7. A Simple Surface-Enhanced Raman Spectroscopic Method for on-Site Screening of Tetracycline Residue in Whole Milk.

    Science.gov (United States)

    Dhakal, Sagar; Chao, Kuanglin; Huang, Qing; Kim, Moon; Schmidt, Walter; Qin, Jianwei; Broadhurst, C Leigh

    2018-02-01

    Therapeutic and subtherapeutic use of veterinary drugs has increased the risk of residue contamination in animal food products. Antibiotics such as tetracycline are used for mastitis treatment of lactating cows. Milk expressed from treated cows before the withdrawal period has elapsed may contain tetracycline residue. This study developed a simple surface-enhanced Raman spectroscopic (SERS) method for on-site screening of tetracycline residue in milk and water. Six batches of silver colloid nanoparticles were prepared for surface enhancement measurement. Milk-tetracycline and water-tetracycline solutions were prepared at seven concentration levels (1000, 500, 100, 10, 1, 0.1, and 0.01 ppm) and spiked with silver colloid nanoparticles. A 785 nm Raman spectroscopic system was used for spectral measurement. Tetracycline vibrational modes were observed at 1285, 1317 and 1632 cm -1 in water-tetracycline solutions and 1322 and 1621 cm -1 (shifted from 1317 and 1632 cm -1 , respectively) in milk-tetracycline solutions. Tetracycline residue concentration as low as 0.01 ppm was detected in both the solutions. The peak intensities at 1285 and 1322 cm -1 were used to estimate the tetracycline concentrations in water and milk with correlation coefficients of 0.92 for water and 0.88 for milk. Results indicate that this SERS method is a potential tool that can be used on-site at field production for qualitative and quantitative detection of tetracycline residues.

  8. Focus on agricultural residues: Microstructure of almond hull (abstract)

    Science.gov (United States)

    Agricultural residues have historically been used as animal feed or burned for disposal. These residues, therefore, have little economic value and may end up becoming disposal problems because tighter air quality control measures may limit burning of the residues. Therefore, value-added products mad...

  9. Measurement of residual strain in composites by means of time-of- flight neutron diffraction

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Majumdar, S.; Richardson, J.; Saigal, A.

    1993-01-01

    Neutron diffraction time-of-flight measurements using the Intense Pulsed Neutron Source at Argonne National Laboratory have been employed to study strain in various metal- and ceramic-matrix composites. For example, measurements carried out to 900 C on a composite composed of a titanium alloy matrix and silicon carbide fibers have been used to validate theoretical assumptions in the prediction of fabrication-induced residual stress. Sapphire reinforced nickel aluminide composites have also been studied. Studies of a high-temperature ceramic superconducting composite consisting of yttrium barium copper oxide and silver with various volume fractions of silver have also been carried out. The results of these studies have provided information on the effect of Ag content on interface bonding. In addition, ceramic-matrix composites with randomly dispersed ceramic whiskers with varying fiber content have been investigated

  10. Quantification of Drive-Response Relationships Between Residues During Protein Folding.

    Science.gov (United States)

    Qi, Yifei; Im, Wonpil

    2013-08-13

    Mutual correlation and cooperativity are commonly used to describe residue-residue interactions in protein folding/function. However, these metrics do not provide any information on the causality relationships between residues. Such drive-response relationships are poorly studied in protein folding/function and difficult to measure experimentally due to technical limitations. In this study, using the information theory transfer entropy (TE) that provides a direct measurement of causality between two times series, we have quantified the drive-response relationships between residues in the folding/unfolding processes of four small proteins generated by molecular dynamics simulations. Instead of using a time-averaged single TE value, the time-dependent TE is measured with the Q-scores based on residue-residue contacts and with the statistical significance analysis along the folding/unfolding processes. The TE analysis is able to identify the driving and responding residues that are different from the highly correlated residues revealed by the mutual information analysis. In general, the driving residues have more regular secondary structures, are more buried, and show greater effects on the protein stability as well as folding and unfolding rates. In addition, the dominant driving and responding residues from the TE analysis on the whole trajectory agree with those on a single folding event, demonstrating that the drive-response relationships are preserved in the non-equilibrium process. Our study provides detailed insights into the protein folding process and has potential applications in protein engineering and interpretation of time-dependent residue-based experimental observables for protein function.

  11. Polycyclic Aromatic Hydrocarbon Residues in Serum Samples of Autopsied Individuals from Tennessee

    Directory of Open Access Journals (Sweden)

    Aramandla Ramesh

    2014-12-01

    Full Text Available This study reports the concentrations of Polycyclic Aromatic Hydrocarbons (PAHs in human blood sera samples (n = 650 obtained at autopsy from individuals who died of drug abuse, alcohol toxicity, homicide, suicide and other unknown causes. The analyzed samples from decedents revealed the presence of PAHs of which B(aP was the most predominant one, followed by benzo(bfluoranthene and benzo(kfluoranthene. The other PAHs detected sporadically and measured were benzo(g,h,iperylene, acenaphthene, anthracene, phenanthrene, and fluoranthene The mean concentrations of PAHs were greater in the twenties to fifties age groups compared to others. The PAH residue levels detected were high in African Americans compared to Caucasians, Asians, and Hispanics. It appears that environmental exposure, dietary intake and in some cases occupational exposure may have contributed to the PAH body burden. While the PAH residue concentrations measured fall within the range of those reported for healthy adults elsewhere, in isolated cases, the concentrations detected were high, calling the need for a reduction in PAH emissions and human biomonitoring studies for purposes of risk assessment.

  12. Review of environmental exposure concentrations of chemical warfare agent residues and associated the fish community risk following the construction and completion of the Nord Stream gas pipeline between Russia and Germany.

    Science.gov (United States)

    Sanderson, Hans; Fauser, Patrik; Rahbek, Malene; Larsen, Jørn Bo

    2014-08-30

    This paper compiles all the measured chemical warfare agent (CWA) concentrations found in relation to the Nord Stream pipeline work in Danish waters for the past 5 years. Sediment and biota sampling were performed along the pipeline route in four campaigns, prior to (in 2008 and 2010), during (in 2011) and after (in 2012) the construction work. No parent CWAs were detected in the sediments. Patchy residues of CWA degradation products of Adamsite, Clark I, phenyldichloroarsine, trichloroarsine and Lewisite II, were detected in a total of 29 of the 391 sediment samples collected and analyzed the past 5 years. The cumulative fish community risk quotient for the different locations, calculated as a sum of background and added risk, ranged between 0 and 0.017 suggesting a negligible acute CWA risk toward the fish community. The added risk from sediment disturbance in relation to construction of the pipelines represents less than 2% of the total risk in the areas with the highest calculated risk. The analyses of benthic infauna corroborate the finding of CWA related low risk across the years. There was no significant difference in CWA risk before (2008) and after the pipeline construction (2012). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The residual and direct effects of reduced-risk and conventional miticides on twospotted spider mites, Tetranychus urticae (Acari: Tetranychidae) and predatory mites (Acari: Phytoseiidae)

    International Nuclear Information System (INIS)

    Liburd, O.E.; White, J.C.; Rhodes, E.M.; Browdy, A.A.

    2007-01-01

    The residual effects of several reduced-risk and conventional miticides were evaluated in strawberries (Fragaria × ananassa Duchesne) on the twospotted spider mite (TSSM), Tetranychus urticae Koch (Acari: Tetranychidae) and on 2 predatory mites, Neoseiulus californicus McGregor and Phytoseiulus persimilis Athias-Henriot (Acari: Phytoseiidae). Experiments were conducted in the laboratory and greenhouse. The greenhouse experiments also tested the direct effects of the miticides on TSSM. The efficacy of conventional and reduced-risk miticides was evaluated on strawberry leaf discs and on whole plants for control of TSSM. Furthermore, the residual effects of these miticides were evaluated on whole strawberry plants against selective predatory mites. For TSSM, 5 treatments were evaluated: a conventional miticide; fenbutatin-oxide (Vendex[reg]) and 3 reduced-risk miticides; binfenazate (Acramite 50WP[reg]), activated garlic extract (Repel[reg]), sesame seed and castor oil (Wipeout[reg]), and a water-treated control. For predatory mites, the residual effects of only Acramite[reg] and Vendex[reg] were evaluated. Acramite[reg] was the most effective acaricide in reducing TSSM populations in both the laboratory and greenhouse experiments. Vendex[reg] and Wipeout[reg] were also effective in the laboratory, but did not cause significant reduction of TSSM in the greenhouse. Repel[reg] was the least effective of the 4 pesticides evaluated. Neither Acramite[reg] nor Vendex[reg] had a significant effect on either predatory mite species. However, there appeared to be more predatory mites on the Vendex[reg]-treated plants than on the Acramite[reg]-treated plants. There were significantly more predatory mites of both species on the cue plants, which were inoculated with TSSM versus the non-cue plants, which were not inoculated. (author) [es

  14. Residual dust charges in discharge afterglow

    International Nuclear Information System (INIS)

    Coueedel, L.; Mikikian, M.; Boufendi, L.; Samarian, A. A.

    2006-01-01

    An on-ground measurement of dust-particle residual charges in the afterglow of a dusty plasma was performed in a rf discharge. An upward thermophoretic force was used to balance the gravitational force. It was found that positively charged, negatively charged, and neutral dust particles coexisted for more than 1 min after the discharge was switched off. The mean residual charge for 200-nm-radius particles was measured. The dust particle mean charge is about -5e at a pressure of 1.2 mbar and about -3e at a pressure of 0.4 mbar

  15. Analysis and radiological assessment of residues containing NORM materials resulting from earlier activities including modelling of typical industrial residues. Pt. 1. Historical investigation of the radiological relevance of NORM residues and concepts for site identification

    International Nuclear Information System (INIS)

    Reichelt, Andreas; Niedermayer, Matthias; Sitte, Beate; Hamel, Peter Michael

    2007-01-01

    Natural radionuclides are part of the human environment and of the raw materials used. Technical processes may cause their accumulation in residues, and the result will be so-called NORM materials (Naturally occurring radioactive material). The amended Radiation Protection Ordinance (StrlSchV 2001) specifies how the public should be protected, but there are also residues dating back before the issuing of the StrlSchV 2001, the so-called NORM residues. The project intended to assess the risks resulting from these residues. It comprises four parts. Part 1 was for clarification of the radiological relevance of NORM residues and for the development of concepts to detect them. The criterion for their radiological relevance was their activity per mass unit and the material volume accumulated through the centuries. The former was calculated from a wide bibliographic search in the relevant literature on radiation protection, while the mass volume was obtained by a detailed historical search of the consumption of materials that may leave NORM residues. These are, in particular, residues from coal and ore mining and processing. To identify concrete sites, relevant data sources were identified, and a concept for identification of concrete NORM residues was developed on this basis. (orig.) [de

  16. Residual stresses around Vickers indents

    International Nuclear Information System (INIS)

    Pajares, A.; Guiberteau, F.; Steinbrech, R.W.

    1995-01-01

    The residual stresses generated by Vickers indentation in brittle materials and their changes due to annealing and surface removal were studied in 4 mol% yttria partially stabilized zirconia (4Y-PSZ). Three experimental methods to gain information about the residual stress field were applied: (i) crack profile measurements based on serial sectioning, (ii) controlled crack propagation in post indentation bending tests and (iii) double indentation tests with smaller secondary indents located around a larger primary impression. Three zones of different residual stress behavior are deduced from the experiments. Beneath the impression a crack free spherical zone of high hydrostatic stresses exists. This core zone is followed by a transition regime where indentation cracks develop but still experience hydrostatic stresses. Finally, in an outward third zone, the crack contour is entirely governed by the tensile residual stress intensity (elastically deformed region). Annealing and surface removal reduce this crack driving stress intensity. The specific changes of the residual stresses due to the post indentation treatments are described and discussed in detail for the three zones

  17. Residual energy deposition in dental enamel during IR laser ablation at 2.79, 2.94, 9.6, and 10.6 μm

    Science.gov (United States)

    Ragadio, Jerome N.; Lee, Christian K.; Fried, Daniel

    2000-03-01

    The objective of this study was to measure the residual heat deposition during laser ablation at those IR laser wavelengths best suited for the removal of dental caries. The principal factor limiting the rate of laser ablation of dental hard tissue is the risk of excessive heat accumulation in the tooth, which has the potential for causing damage to the pulp. Optimal laser ablation systems minimize the residual energy deposition in the tooth by transferring deposited laser energy to kinetic and internal energy of ejected tissue components. The residual heat deposition in the tooth was measured at laser wavelengths of 2.79, 2.94, 9.6 and 10.6 micrometer and pulse widths of 150 ns - 150 microsecond(s) . The residual energy was at a minimum for fluences well above the ablation threshold where it saturates at values from 25 - 70% depending on pulse duration and wavelength for the systems investigated. The lowest values of the residual energy were measured for short (less than 20 microseconds) CO2 laser pulses at 9.6 micrometer and for Q-switched erbium laser pulses. This work was supported by NIH/NIDCR R29DE12091 and the Center for Laser Applications in Medicine, DOE DEFG0398ER62576.

  18. Residual heat deposition in dental enamel during IR laser ablation at 2.79, 2.94, 9.6, and 10.6 microm.

    Science.gov (United States)

    Fried, D; Ragadio, J; Champion, A

    2001-01-01

    The principal factor limiting the rate of laser ablation of dental hard tissue is the risk of excessive heat accumulation in the tooth. Excessive heat deposition or accumulation may result in unacceptable damage to the pulp. The objective of this study was to measure the residual heat deposition during the laser ablation of dental enamel at those IR laser wavelengths well suited for the removal of dental caries. Optimal laser ablation systems minimize the residual heat deposition in the tooth by efficiently transferring the deposited laser energy to kinetic and internal energy of ejected tissue components. The residual heat deposition in dental enamel was measured at laser wavelengths of 2.79, 2.94, 9.6, and 10.6 microm and pulse widths of 150 nsec -150 microsec using bovine block "calorimeters." Water droplets were applied to the surface before ablation with 150 microsec Er:YAG laser pulses to determine the influence of an optically thick water layer on reducing heat deposition. The residual heat was at a minimum for fluences well above the ablation threshold where measured values ranged from 25-70% depending on pulse duration and wavelength for the systems investigated. The lowest values of the residual heat were measured for short (heat deposition during ablation with 150 microsec Er:YAG laser pulses. Residual heat deposition can be markedly reduced by using CO(2) laser pulses of less than 20 microsec duration and shorter Q-switched Er:YAG and Er:YSGG laser pulses for enamel ablation. Copyright 2001 Wiley-Liss, Inc.

  19. Dissipation pattern and risk assessment studies of triazophos residues on capsicum (Capsicum annuum L.) using GLC-FPD and GC-MS.

    Science.gov (United States)

    Singh, Yadwinder; Mandal, Kousik; Singh, Balwinder

    2015-10-01

    The present study was carried out to observe the dissipation pattern of triazophos on capsicum and risk assessment of its residues on human beings and to suggest a waiting period for the safety of consumers. Following two applications of triazophos (Truzo 40 EC) at 500 and 1000 g a.i. ha(-1), the average initial deposits were found to be 3.61 and 6.26 mg kg(-1), respectively. These residues dissipated below the limit of quantification (LOQ) of 0.05 mg kg(-1) in 10 and 15 days at the recommended and double the recommended dosages, respectively. The calculated values of half-life were 2.31 and 2.14 days at recommended and double the recommended dosages, respectively. Theoretical maximum residue contribution (TMRC) values were found to be 28.8 and 41.6 μg person(-1) day(-1) at 500 and 1000 g a.i. ha(-1), respectively, and found to be below the maximum permissible intake on capsicum fruit on the 7th day. Therefore, a waiting period of 7 days is suggested for consumption of capsicum sprayed with triazophos at the recommended dosages.

  20. X-ray diffraction residual stress measurement in the rolled-joint zone of Zr - 2.5 % Nb pressure tube

    International Nuclear Information System (INIS)

    Dinu, A.; Nedelcu, L.

    1995-01-01

    The in-service experience of Zr - 2.5 % Nb pressure tubes in CANDU-type nuclear reactors has demonstrated very good performance over a long period of time. However, analyses done by AECL specialists on most failure cases, showed that a big percentage of defects are manufacturing defects, which appear mostly at the beginning of the rolled-joint zone. It has been observed that a correct rolling ensures an acceptable distribution of residual stress, but an incorrect one leads to an accumulation of big values of residual stress. This determines a preferential radial orientation of hydrides, which during operation in the reactor can produce DHC. To ensure a suitable performance of the Zr - 2.5 % Nb pressure tubes in the CANDU reactor, it is very important to have a correct rolling as mentioned in the procedure. This work presents a methodology for the measurement of the stressing state in the surfaces layers of the rolled-joint zone. The X-ray diffraction method can also be used for establishing the residual stress distribution across the tub wall, in order to ensure a good performance at Cernavoda nuclear plant. The results obtained for the investigated tube have led to the conclusion that the rolling process was correctly applied in this case, the values obtained for the residual stress being in good agreement with those accepted in literature. (Author) 2 Figs., 2 Tabs

  1. Liquidity Risk meets Economic Capital and RAROC. A framework for measuring liquidity risk in banks.

    OpenAIRE

    Loebnitz, K.

    2011-01-01

    Liquidity risk is a crucial and inherent feature of the business model of banks. While banks and regulators use sophisticated mathematical methods to measure a bank's solvency risk, they use relatively simple tools for a bank's liquidity risk such as coverage ratios, sensitivity analyses, and scenario analyses. In this thesis we present a more rigorous framework that allows us to measure a bank's liquidity risk within the standard economic capital and RAROC setting. In particular, we introduc...

  2. Residual Stress Studies Using the Cairo Fourier Diffractometer Facility

    International Nuclear Information System (INIS)

    Maayouf, R.M.A.; El-Shaer, Y.H.

    2002-01-01

    The present paper deals with residual stress studies using the Cairo Fourier diffractometer facility CFDF. The CFDF is a reverse - time of -flight (RTOF) diffractometer; applies a Fourier chopper. The measurements were performed for copper samples in order to study the residual stress after welding. The maximum modulation of the Fourier chopper during the measurements was 136 khz; leading to a time resolution half-width of about 7 μ s. It has been found from the present measurements that, the resulting diffraction spectra could be successfully used for studying the residual stress; in the wavelength range between 0.7-2.9 A degree at ∼ 0.45 % relative resolution

  3. Risk-based environmental assessment for uranium mines – Some Canadian and Australian experience

    International Nuclear Information System (INIS)

    Phaneuf, M.; McKee, M.; Woods, P.

    2014-01-01

    The Risk-Based Approach to Environmental Assessment in Australia: • This has emerged over the last 2 decades; • Currently usually based around the Australian and New Zealand standard (AS4360:1999) for risk assessment: • Potential impact events; • Inherent risk levels (e.g. low, moderate) using a matrix approach; • Design and operational control measures; • Residual risk levels; • Outcomes to be achieved; • Outcomes measurement criteria - • Leading to ‘compliance’ monitoring; • Leading indicator criteria - • Leading to ‘early warning’ monitoring

  4. On set-valued functionals: Multivariate risk measures and Aumann integrals

    Science.gov (United States)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In

  5. Comparison of destructive and nondestructive assay of heterogeneous salt residues

    International Nuclear Information System (INIS)

    Fleissner, J.G.; Hume, M.W.

    1986-01-01

    To study problems associated with nondestructive assay (NDA) measurements of molten salt residues, a joint study was conducted by the Rocky Flats Plant, Golden, CO and Mound Laboratories, Miamisburg, OH. Extensive NDA measurements were made on nine containers of molten salt residues by both Rocky Flats and Mound followed by dissolution and solution quantification at Rocky Flats. Results of this study verify that plutonium and americium can be measured in such salt residues by a new gamma-ray spectral analysis technique coupled with calorimetry. Biases with respect to the segmented gamma-scan technique were noted

  6. An overview of the NeT international round-robin programme: weld residual stress measurement and modelling in nuclear materials

    International Nuclear Information System (INIS)

    Reid, M.H.; Hamelin, C.J.

    2016-01-01

    This talk provides an overview of the European Network on Neutron Techniques Standardisation for Structural Integrity (NeT). The network involves some 35 organisations from industry and academia, whose goal is to identify best practice in the application of modern experimental and numerical techniques to problems related to the structural integrity of components, mainly relevant to nuclear applications. While the programme was originally built around neutron scattering techniques for residual stress measurement, it has grown considerably to include studies of X-ray diffraction, deep-hole drilling, the contour method and other measurement techniques. Significant efforts have also been made within NeT to understand and predict weld residual stresses, often employing commercially available finite element (FE) codes. Several Task Groups have been developed to address unique challenges found in nuclear applications, from stress development in multi-pass AISI 316LN austenitic steel welds to the effects of solid-state phase transformation on residual stress development in SA508 ferritic steel, which is often used for reactor pressure vessel (RPV) construction. Some current and future work performed under the auspices of NeT are provided, with a focus on work Conducted at ANSTO. The aim is to give the audience a comprehensive overview of the work undertaken in NeT, and to shed some light on the potential present in this kind of collaborative effort. (author)

  7. On-treatment non-high-density lipoprotein cholesterol, apolipoprotein B, triglycerides, and lipid ratios in relation to residual vascular risk after treatment with potent statin therapy

    DEFF Research Database (Denmark)

    Mora, Samia; Glynn, Robert J; Boekholdt, S Matthijs

    2012-01-01

    The goal of this study was to determine whether residual risk after high-dose statin therapy for primary prevention individuals with reduced levels of low-density lipoprotein cholesterol (LDL-C) is related to on-treatment apolipoprotein B, non-high-density lipoprotein cholesterol (non-HDL-C), tri...

  8. Monitoring and Auditing Residual Information on the User’s Computer

    Directory of Open Access Journals (Sweden)

    Vladlena Sergeevna Oladk

    2015-06-01

    Full Text Available This paper considers the problem of violation of information security components such as confidentiality and availability in the event of a computer user's residual information. Analyze the requirements of regulators and mechanisms to be applied in the organization to monitor the residual information or its destruction.Approach to monitoring and auditing residual information on the user's computer, which allows monitoring the residual information in certain areas proposed. Approach allows us to identify the detected information and rank it according to the degree of criticality, as well as calculate the risk of leakage and its potential to develop recommendations aimed at its reduction. The proposed approach is formally described and automated in a software system.

  9. The Basel II Accord on Measuring and Managing a Bank's Risks

    Directory of Open Access Journals (Sweden)

    Ion Stancu

    2007-11-01

    Full Text Available The abundance of risk metrics stems from the effort to measure the difference between the expected and actual returns, under a hypothesis of normality. Under the assumption of risk aversion, investors are likely to quantify risk using metrics which measure returns lower than the expected average. These include the semi-variance of returns smaller than the average, the risk of loss – a return under a chosen level, usually 0%, and value-at-risk, for the greatest losses, with a probability of less than 1-5% in a given period of time. The Basel II accord improves on the way risks are measured, by allowing banks greater flexibility. There is an increase in the complexity of measuring credit risks, the market risks measurement methods remain the same, and the measurement of operational risk is introduced for the first time. The most advanced (and widely-used risk metrics are based on VaR. However, it must be noted that VaR calculations are statistical, and therefore unlikely to forecast extraordinary events. So the quality of a VaR calculation must be checked using back-testing, and if the VaR value fails in a percentage of 1-5% of the cases, then the premises of the model must be changed.

  10. Use of importance measures in risk-informed regulatory applications

    International Nuclear Information System (INIS)

    Cheok, Michael C.; Parry, Gareth W.; Sherry, Richard R.

    1998-01-01

    The use of importance measures to analyze PRA results is discussed. Commonly used importance measures are defined. Some issues that have been identified as potentially limiting their usefulness are addressed, namely: there is no simple relationship between importance measures evaluated at the single component level and those evaluated at the level of a group of components, and, as a result, some of the commonly used importance measures are not realistic measures of the sensitivity of the overall risk to parameter value changes; and, importance measures do not typically take into account parameter uncertainties which raises the question of the robustness of conclusions drawn from importance analyses. The issues are explored in the context of both ranking and categorization of structures, systems, and components (SSCs) with respect to risk-significance and safety-significance for use in risk-informed regulatory analyses

  11. Estimation of average causal effect using the restricted mean residual lifetime as effect measure

    DEFF Research Database (Denmark)

    Mansourvar, Zahra; Martinussen, Torben

    2017-01-01

    with respect to their survival times. In observational studies where the factor of interest is not randomized, covariate adjustment is needed to take into account imbalances in confounding factors. In this article, we develop an estimator for the average causal treatment difference using the restricted mean...... residual lifetime as target parameter. We account for confounding factors using the Aalen additive hazards model. Large sample property of the proposed estimator is established and simulation studies are conducted in order to assess small sample performance of the resulting estimator. The method is also......Although mean residual lifetime is often of interest in biomedical studies, restricted mean residual lifetime must be considered in order to accommodate censoring. Differences in the restricted mean residual lifetime can be used as an appropriate quantity for comparing different treatment groups...

  12. Large breast size as a risk factor for late adverse effects of breast radiotherapy: Is residual dose inhomogeneity, despite 3D treatment planning and delivery, the main explanation?

    International Nuclear Information System (INIS)

    Goldsmith, Christy; Haviland, Joanne; Tsang, Yat; Sydenham, Mark; Yarnold, John

    2011-01-01

    Background and Purpose: Large breast size is associated with an increased risk of late adverse effects after breast conservation surgery and radiotherapy, even when 3D dosimetry is used. The purpose of this study is to test the hypothesis that residual dose inhomogeneity is sufficient to explain the association. Methods: Patients previously treated after breast conservation surgery with whole breast radiotherapy using 3D dosimetry and followed up in the UK FAST hypofractionation trial were selected for this analysis. The residual level of dose inhomogeneity across the whole breast treatment volume was used to test for association between residual dosimetry and post-treatment change in breast appearance at 2 years post-radiotherapy. Results: At 2 years, 201/279 (72%) of women had no change in photographic breast appearance, 61 (22%) had mild change and 17 (6%) had marked change. Breast size and dosimetry were both significantly associated with late effects in univariate analyses, but only breast size remained an independent significant risk factor for change in breast appearance when included in a multiple regression model together with other prognostic factors (p = 0.006 for trend). Conclusion: Large-breasted women are more likely to suffer change in breast size and shape after whole breast radiotherapy delivered using 3D dosimetry, but residual dose inhomogeneity is insufficient to explain the association.

  13. Measurement of Young’s modulus and residual stress of atomic layer deposited Al2O3 and Pt thin films

    Science.gov (United States)

    Purkl, Fabian; Daus, Alwin; English, Timothy S.; Provine, J.; Feyh, Ando; Urban, Gerald; Kenny, Thomas W.

    2017-08-01

    The accurate measurement of mechanical properties of thin films is required for the design of reliable nano/micro-electromechanical devices but is increasingly challenging for thicknesses approaching a few nanometers. We apply a combination of resonant and static mechanical test structures to measure elastic constants and residual stresses of 8-27 nm thick Al2O3 and Pt layers which have been fabricated through atomic layer deposition. Young’s modulus of poly-crystalline Pt films was found to be reduced by less than 15% compared to the bulk value, whereas for amorphous Al2O3 it was reduced to about half of its bulk value. We observed no discernible dependence of the elastic constant on thickness or deposition method for Pt, but the use of plasma-enhanced atomic layer deposition was found to increase Young’s modulus of Al2O3 by 10% compared to a thermal atomic layer deposition. As deposited, the Al2O3 layers had an average tensile residual stress of 131 MPa. The stress was found to be higher for thinner layers and layers deposited without the help of a remote plasma. No residual stress values could be extracted for Pt due to insufficient adhesion of the film without an underlying layer to promote nucleation.

  14. Residual volume in vials of antibiotics used in pediatrics.

    Science.gov (United States)

    Chaves, Caroline Magna Pessoa; Bezerra, Carolina Martins; Lima, Francisca Elisângela Teixeira; Cardoso, Maria Vera Lúcia Moreira Leitão; Fonseca, Said Gonçalves da Cruz; Silva, Viviane Martins da

    2017-06-12

    Quantifying residual volume contained in vials of antibiotics used in pediatrics. This is an experiment involving samples from vials of antibiotics used in a pediatric hospital. Residual volume was identified by calculating the difference in weight measurement before and after the vials were washed. Evaluation of the residual volume difference in the vials was determined by the Wilcoxon non-parametric test for a sample and established at a significance level of 5%. 105 samples of antibiotics were selected. The correct use of the antibiotics oxacillin (88.57%) and ceftriaxone (94.28%) predominated with low residual values. The same did not occur for procaine benzylpenicillin + potassium benzylpenicillin, since a greater residual volume was discarded in 74.28% of the vials. We highlight the need for improvements in managing antibiotics in the institution under study, so that the excess volume of the antibiotics in the vials is used within the acceptable stable time. It is also necessary that the disposal of the residual volume be adequately disposed, since it presents a risk to public health and the environment. Quantificar o volume residual contido em frascos-ampola de antibióticos utilizados na pediatria. Trata-se de um experimento com amostras de frascos-ampola de antibióticos utilizados em hospital pediátrico. O volume residual foi identificado calculando-se a diferença da aferição do peso antes e após a lavagem do frasco-ampola. A avaliação da diferença dos volumes residuais nos frascos-ampola foi determinada pelo teste não paramétrico de Wilcoxon para uma amostra e estabelecido o nível de significância de 5%. Foram selecionadas 105 amostras de antibióticos. Predominou o correto aproveitamento dos antibióticos oxacilina (88,57%) e ceftriaxona (94,28%), com baixos valores residuais. O mesmo não ocorreu com a benzilpenicilina procaína + potássica, pois em 74,28% dos frascos houve descarte de volume residual superior. Destaca-se a necessidade de

  15. A Security Risk Measurement for the RAdAC Model

    National Research Council Canada - National Science Library

    Britton, David W; Brown, Ian A

    2007-01-01

    .... The intent is to quantify the risk involved in a single information transaction. Additionally, this thesis will attempt to identify the risk factors involved when calculating the total security risk measurement...

  16. Measurement of residual stresses in deposited films of SOFC component materials

    Energy Technology Data Exchange (ETDEWEB)

    Kato, T.; Momma, A.; Nagata, S.; Kasuga, Y. [Electrotechnical Lab., Ibaraki (Japan)

    1996-12-31

    The stress induced in Solid oxide fuel cells (SOFC)s has important influence on the lifetime of SOFC. But the data on stress in SOFC and mechanical properties of SOW component materials have not been accumulated enough to manufacture SOFC. Especially, the data of La{sub 1-x}Sr{sub x}MnO{sub 3} cathode and La{sub 1-x}Sr{sub x}CrO{sub 3} interconnection have been extremely limited. We have estimated numerically the dependences of residual stress in SOFC on the material properties, the cell structure and the fabrication temperatures of the components, but these unknown factors have caused obstruction to simulate the accurate behavior of residual stress. Therefore, the residual stresses in deposited La{sub 1-x}Sr{sub x}MnO{sub 3} and La{sub 1-x}Sr{sub x}CrO{sub 3} films are researched by the observation of the bending behavior of the substrate strips. The films of SOFC component materials were prepared by the RF sputtering method, because: (1) It can fabricate dense films of poor sinterable material such as La{sub 1-x}Sr{sub x}CrO{sub 3} compared with sintering or plasma spray method. (2) For the complicated material such as perovskite materials, the difference between the composition of a film and that of a target material is generally small. (3) It can fabricate a thick ceramics film by improving of the deposition rate. For example, Al{sub 2}O{sub 3} thick films of 50{mu}m can be fabricated with the deposition rate of approximately 5{mu}m/h industrially. In this paper, the dependence of residual stress on the deposition conditions is defined and mechanical properties of these materials are estimated from the results of the experiments.

  17. Rapid multi-residue method for the determination of pesticide ...

    African Journals Online (AJOL)

    Exposure to pesticides can represent a potential risk to humans. Agricultural workers are at risk of chronic toxicity. Hence, the evaluation of pesticide residues in their blood gives an indication about the extent of exposure and help in assessing adverse health effects. The aim of our study was to develop analytical method for ...

  18. Influence of thermal expansion mismatch on residual stress profile in veneering ceramic layered on zirconia: Measurement by hole-drilling.

    Science.gov (United States)

    Mainjot, Amélie K; Najjar, Achref; Jakubowicz-Kohen, Boris D; Sadoun, Michaël J

    2015-09-01

    Mismatch in thermal expansion coefficient between core and veneering ceramic (Δα=αcore-αveneer, ppm/°C) is reported as a crucial parameter influencing veneer fractures with Yttria-tetragonal-zirconia-polycrystal (Y-TZP) prostheses, which still constitutes a misunderstood problem. However, the common positive Δα concept remains empirical. The objective of this study is to investigate the Δα dependence of residual stress profiles in veneering ceramic layered on Y-TZP frameworks. The stress profile was measured with the hole-drilling method in bilayered disc samples of 20mm diameter with a 0.7mm thick Y-TZP framework and a 1.5mm thick veneer layer. 3 commercial and 4 experimental veneering ceramics (n=3 per group) were used to obtain different Δα varying from -1.3ppm/°C to +3.2ppm/°C, which were determined by dilatometric analyses. Veneer fractures were observed in samples with Δα≥+2.3 or ≤-0.3ppm/°C. Residual stress profiles measured in other groups showed compressive stresses in the surface, these stresses decreasing with depth and then becoming more compressive again near the interface. Small Δα variations were shown to induce significant changes in residual stress profiles. Compressive stress near the framework was found to decrease inversely to Δα. Veneer CTE close to Y-TZP (+0.2ppm/°C Δα) gived the most favorable stress profile. Yet, near the framework, Δα-induced residual stress varied inversely to predictions. This could be explained by the hypothesis of structural changes occurrence within the Y-TZP surface. Consequently, the optimum Δα value cannot be determined before understanding Y-TZP's particular behavior when veneered. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Residual DNA analysis in biologics development: review of measurement and quantitation technologies and future directions.

    Science.gov (United States)

    Wang, Xing; Morgan, Donna M; Wang, Gan; Mozier, Ned M

    2012-02-01

    Residual DNA (rDNA) is comprised of deoxyribonucleic acid (DNA) fragments and longer length molecules originating from the host organism that may be present in samples from recombinant biological processes. Although similar in basic structural base pair units, rDNA may exist in different sizes and physical forms. Interest in measuring rDNA in recombinant products is based primarily on demonstration of effective purification during manufacturing, but also on some hypothetical concerns that, in rare cases, depending on the host expression system, some DNA sequences may be potentially infectious or oncogenic (e.g., HIV virus and the Ras oncogene, respectively). Recent studies suggest that a sequence known as long interspersed nucleotide element-1 (LINE-1), widely distributed in the mammalian genome, is active as a retrotransposon that can be transcribed to RNA, reverse-transcribed into DNA and inserts into a new site in genome. This integration process could potentially disrupt critical gene functions or induce tumorigenesis in mammals. Genomic DNA from microbial sources, on the other hand, could add to risk of immunogenicity to the target recombinant protein being expressed, due to the high CpG content and unmethylated DNA sequence. For these and other reasons, it is necessary for manufacturers to show clearance of DNA throughout production processes and to confirm low levels in the final drug substance using an appropriately specific and quantitative analytical method. The heterogeneity of potential rDNA sequences that might be makes the testing of all potential analytes challenging. The most common methodology for rDNA quantitation used currently is real-time polymerase chain reaction (RT-PCR), a robust and proven technology. Like most rDNA quantitation methods, the specificity of RT-PCR is limited by the sequences to which the primers are directed. To address this, primase-based whole genome amplification is introduced herein. This paper will review the recent

  20. Presence, concentrations and risk assessment of selected antibiotic residues in sediments and near-bottom waters collected from the Polish coastal zone in the southern Baltic Sea - Summary of 3years of studies.

    Science.gov (United States)

    Siedlewicz, Grzegorz; Białk-Bielińska, Anna; Borecka, Marta; Winogradow, Aleksandra; Stepnowski, Piotr; Pazdro, Ksenia

    2018-04-01

    Concentrations of selected antibiotic compounds from different groups were measured in sediment samples (14 analytes) and in near-bottom water samples (12 analytes) collected in 2011-2013 from the southern Baltic Sea (Polish coastal zone). Antibiotics were determined at concentration levels of a few to hundreds of ng g -1 d.w. in sediments and ng L -1 in near-bottom waters. The most frequently detected compounds were sulfamethoxazole, trimethoprim, oxytetracycline in sediments and sulfamethoxazole and trimethoprim in near-bottom waters. The occurrence of the identified antibiotics was characterized by spatial and temporal variability. A statistically important correlation was observed between sediment organic matter content and the concentrations of sulfachloropyridazine and oxytetracycline. Risk assessment analyses revealed a potential high risk of sulfamethoxazole contamination in near-bottom waters and of contamination by sulfamethoxazole, trimethoprim and tetracyclines in sediments. Both chemical and risk assessment analyses show that the coastal area of the southern Baltic Sea is highly exposed to antibiotic residues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A hierarchical procedure for calculation of risk importance measures

    International Nuclear Information System (INIS)

    Poern, K.; Dinsmore, S.C.

    1987-01-01

    Starting with a general importance definition based on conditional probabilities, a hierarchical process for calculating risk importance measures from a PSA's numerical results is developed. By the appropriate choice of events in the general definition, measures such as the risk achievement worth and the risk reduction worth can be calculated without requantifying the PSA's models. Required approximations are clearly defined and the subsequent constraints on the applicability of the process discussed. (orig.)

  2. Detection and measurement of gamma-ray self-attenuation in plutonium residues

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Foster, L.A.; Estep, R.J.

    1996-01-01

    A new method to correct for self-attenuation in gamma-ray assays of plutonium is presented. The underlying assumptions of the technique are based on a simple but accurate physical model of plutonium residues, particularly pyrochemical salts, in which it is assumed that the plutonium is divided into two portions, each of which can be treated separately from the standpoint of gamma-ray analysis: a portion that is in the form of plutonium metal shot; and a dilute portion that is mixed with the matrix. The performance of the technique is evaluated using assays of plutonium residues by tomographic gamma scanning at the Los Alamos Plutonium Facility. The ability of the method to detect saturation conditions is examined

  3. Residual stress measurement of PMMA by combining drilling-hole with digital speckle correlation method

    Science.gov (United States)

    Yao, X. F.; Xiong, T. C.; Xu, H. M.; Wan, J. P.; Long, G. R.

    2008-11-01

    The residual stresses of the PMMA (polymethyl methacrylate) specimens after being drilled, reamed and polished respectively are investigated using the digital speckle correlation experimental method,. According to the displacement fields around the correlated calculated region, the polynomial curve fitting method is used to obtain the continuous displacement fields, and the strain fields can be obtained from the derivative of the displacement fields. Considering the constitutive equation of the material, the expression of the residual stress can be presented. During the data processing, according to the fitting effect of the data, the calculation region of the correlated speckles and the degree of the polynomial fitting curve is decided. These results show that the maximum stress is at the hole-wall of the drilling hole specimen and with the increasing of the diameter of the drilled hole, the residual stress resulting from the hole drilling increases, whereas the process of reaming and polishing hole can reduce the residual stress. The relative large discrete degree of the residual stress is due to the chip removal ability of the drill bit, the cutting feed of the drill and other various reasons.

  4. Radiation effects on residual voltage of polyethylene films

    International Nuclear Information System (INIS)

    Kyokane, Jun; Park, Dae-Hee; Yoshino, Katsumi.

    1986-01-01

    It has recently been pointed out that diagnosis of deterioration in insulating materials for electric cables used in nuclear power plants and outer space (communications satellite in particular) can be effectively performed based on measurements of residual voltage. In the present study, polyethylene films are irradiated with γ-rays or electron beam to examine the changes in residual voltage characteristics. Irradiation of electron beam and γ-rays are carried out to a dose of 0 - 90 Mrad and 0 - 100 Mrad, respectively. Measurements are made of the dependence of residual voltage on applied voltage, electron beam and γ-ray irradiation, annealing temperature and annealing time. Results show that carriers, which are once trapped after being released from the electrode, move within the material after the opening of the circuit to produce resiual voltage. The residual voltage increases with increasing dose of electron beam or γ-ray and levels off at high dose. Residual voltage is increased about several times by either electron beam or γ-rays, but electron beam tends to cause greater residual voltage than γ-ray. Polyethylene films irradiated with electron beam can recover upon annealing. It is concluded from observations made that residual voltage has close relations with defects in molecular structures caused by radiations, particularly the breaking of backbone chains and alteration in superstructures. (Nogami, K.)

  5. Evaluation of pesticide residues in oranges from São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Viviane Emi NAKANO

    2016-01-01

    Full Text Available Pesticides in “PERA” orange samples (N = 57 from São Paulo City, Brazil were assessed and the pesticide intake contribution was estimated for chronic risk assessment. Seventy-six pesticides were evaluated by the gas chromatography multi-residue method, including isomers and metabolites (4.332 determinations. The mean recoveries at the limit of quantification level were in the range of 72-115% and the relative standard deviation for five replicate samples was 1-11%. The limits of detection and quantification ranged from 0.005 to 0.4 mg.kg−1 and from 0.01 to 0.8 mg.kg−1, respectively. Pesticides were found in 42.1% of the samples at levels ranging from 0.06 to 2.9 mg.kg−1. Of the contaminated samples, 3.5% contained residues (bifenthrin and clofentezine above the maximum residue level and 12.3% contained unauthorized pesticides (azinphos-ethyl, parathion, myclobutanil, profenofos, and fenitrothion. The estimated risk characterization for orange intake by adults and children, respectively, ranged from 0.04 to 6.6% and from 0.1 to 26.5% of the acceptable daily intake. The detection of irregular residues emphasizes the need for better implementation of Good Agriculture Practices and greater control of formulated products. Other pesticides surveyed did not pose a health risk due to consumption.

  6. Early detection of tumor relapse/regrowth by consecutive minimal residual disease monitoring in high-risk neuroblastoma patients

    Science.gov (United States)

    Hirase, Satoshi; Saitoh, Atsuro; Hartomo, Tri Budi; Kozaki, Aiko; Yanai, Tomoko; Hasegawa, Daiichiro; Kawasaki, Keiichiro; Kosaka, Yoshiyuki; Matsuo, Masafumi; Yamamoto, Nobuyuki; Mori, Takeshi; Hayakawa, Akira; Iijima, Kazumoto; Nishio, Hisahide; Nishimura, Noriyuki

    2016-01-01

    Neuroblastoma is an aggressive pediatric tumor accounting for ~15% of cancer-associated mortalities in children. Despite the current intensive therapy, >50% of high-risk patients experience tumor relapse or regrowth caused by the activation of minimal residual disease (MRD). Although several MRD detection protocols using various reverse transcription-quantitative polymerase chain reaction (RT-qPCR) markers have been reported to evaluate the therapeutic response and disease status of neuroblastoma patients, their clinical significance remains elusive. The present study reports two high-risk neuroblastoma patients, whose MRD was consecutively monitored using 11 RT-qPCR markers (CHRNA3, CRMP1, DBH, DCX, DDC, GABRB3, GAP43, ISL1, KIF1A, PHOX2B and TH) during their course of treatment. The two patients initially responded to the induction therapy and reached MRD-negative status. The patients' MRD subsequently became positive with no elevation of their urinary homovanillic acid, urinary vanillylmandelic acid and serum neuron-specific enolase levels at 13 or 19 weeks prior to the clinical diagnosis of tumor relapse or regrowth. The present cases highlight the possibility of consecutive MRD monitoring using 11 markers to enable an early detection of tumor relapse or regrowth in high-risk neuroblastoma patients. PMID:27446404

  7. Fluorescence imaging to quantify crop residue cover

    Science.gov (United States)

    Daughtry, C. S. T.; Mcmurtrey, J. E., III; Chappelle, E. W.

    1994-01-01

    Crop residues, the portion of the crop left in the field after harvest, can be an important management factor in controlling soil erosion. Methods to quantify residue cover are needed that are rapid, accurate, and objective. Scenes with known amounts of crop residue were illuminated with long wave ultraviolet (UV) radiation and fluorescence images were recorded with an intensified video camera fitted with a 453 to 488 nm band pass filter. A light colored soil and a dark colored soil were used as background for the weathered soybean stems. Residue cover was determined by counting the proportion of the pixels in the image with fluorescence values greater than a threshold. Soil pixels had the lowest gray levels in the images. The values of the soybean residue pixels spanned nearly the full range of the 8-bit video data. Classification accuracies typically were within 3(absolute units) of measured cover values. Video imaging can provide an intuitive understanding of the fraction of the soil covered by residue.

  8. The Method of Validity Evaluation of Hard Coal Excavation in Residual Seam Parts

    Science.gov (United States)

    Wodarski, Krzysztof; Bijańska, Jolanta; Gumiński, Adam

    2017-12-01

    The excavation of residual seam parts should be justified by positive assessment of the purposefulness, technical feasibility and economic effectiveness. The results of the profitability evaluation are crucial in a decision making process. The excavation of residual seam parts, even if it is possible from a technical point of view, should not be implemented if it is economically inefficient or when accompanied by a very high risk of non-recovery of invested capital resources. The article presents the evaluation method of possibilities of excavating hard coal from residual seam parts, and the example of its use in one of collieries in the Upper Silesian Coal Basin. Working in line with the developed method, allows to indicate the variant of residual seam part exploitation, which is feasible to implement from a technical point of view, and which is characterized by the highest economic effectiveness and lowest risk.

  9. Residual stress in spin-cast polyurethane thin films

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hong; Zhang, Li, E-mail: lizhang@mae.cuhk.edu.hk [Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin N.T., Hong Kong (China); Chow Yuk Ho Technology Centre for Innovative Medicine, The Chinese University of Hong Kong, Shatin N.T., Hong Kong (China)

    2015-01-19

    Residual stress is inevitable during spin-casting. Herein, we report a straightforward method to evaluate the residual stress in as-cast polyurethane thin films using area shrinkage measurement of films in floating state, which shows that the residual stress is independent of radial location on the substrate and decreased with decreasing film thickness below a critical value. We demonstrate that the residual stress is developed due to the solvent evaporation after vitrification during spin-casting and the polymer chains in thin films may undergo vitrification at an increased concentration. The buildup of residual stress in spin-cast polymer films provides an insight into the size effects on the nature of polymer thin films.

  10. Residual stress studies of austenitic and ferritic steels

    International Nuclear Information System (INIS)

    Chrenko, R.M.

    1978-01-01

    Residual studies have been made on austenitic and ferritic steels of the types used as structural materials. The residual stress results presented here will include residual stress measurements in the heat-affected zone on butt welded Type 304 stainless steel pipes, and the stresses induced in Type 304 austenitic stainless steel and Type A508 ferritic steel by several surface preparations. Such surface preparation procedures as machining and grinding can induce large directionality effects in the residual stresses determined by X-ray techniques and some typical data will be presented. A brief description is given of the mobile X-ray residual stress apparatus used to obtain most of the data in these studies. (author)

  11. Compressive residual stresses as a preventive measure against stress corrosion cracking on turbine components

    International Nuclear Information System (INIS)

    Berger, C.; Ewald, J.; Fischer, K.; Gruendler, O.; Potthast, E.; Stuecker, E.; Winzen, G.

    1987-01-01

    Disk type low pressure turbine rotors have been designed for a large variety of power plant applications. Developing disk type rotors required a concerted effort to design a shaft/disk shrink fit with a minimum of tensile stress concentrations in order to aim for the lowest possible susceptibility to corrosive attack, i.e. stress corrosion cracking. As a result of stresses, the regions of greatest concern are the shrink fit boundaries and the keyways of turbine disks. These stresses are caused by service loading, i.e. centrifugal and shrinkage stresses and by manufacturing procedure, i.e. residual stresses. The compressive residual stresses partly compensate the tensile service stresses so that an increase of compressive residual stresses decreases the whole stress state of the component. Special manufacturing procedures, e.g. accelerated cooling after tempering can induce compressive residual stresses up to about 400 MPa in the hub bore region of turbine disk

  12. Improvement and Validation of Weld Residual Stress Modelling Procedure

    International Nuclear Information System (INIS)

    Zang, Weilin; Gunnars, Jens; Dong, Pingsha; Hong, Jeong K.

    2009-06-01

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  13. Improvement and Validation of Weld Residual Stress Modelling Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Weilin; Gunnars, Jens (Inspecta Technology AB, Stockholm (Sweden)); Dong, Pingsha; Hong, Jeong K. (Center for Welded Structures Research, Battelle, Columbus, OH (United States))

    2009-06-15

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  14. Cyolane residues in milk of lactating goats

    International Nuclear Information System (INIS)

    Zayed, S.M.A.D.; Osman, A.; Fakhr, I.M.I.

    1981-01-01

    Consecutive feeding of lactating goats with 14 C-alkyl labelled cyolane for 5 days at dietary levels 8 and 16 ppm resulted in the appearance of measurable insecticide residues in milk (0.02-0.04 mg/kg). The residue levels were markedly reduced after a withdrawal period of 7 days. Analysis of urine and milk residues showed the presence of similar metabolites in addition to the parent compound. The major part of the residue consisted of mono-, diethyl phosphate and 2 hydrophilic unknown metabolites. The erythrocyte cholinesterase activity was reduced to about 50% after 24 hours whereas the plasma enzyme was only slightly affected. The animals remained symptom-free during the experimental period. (author)

  15. Risk Importance Measures in the Designand Operation of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Vrbanic I.; Samanta P.; Basic, I

    2017-10-31

    This monograph presents and discusses risk importance measures as quantified by the probabilistic risk assessment (PRA) models of nuclear power plants (NPPs) developed according to the current standards and practices. Usually, PRA tools calculate risk importance measures related to a single ?basic event? representing particular failure mode. This is, then, reflected in many current PRA applications. The monograph focuses on the concept of ?component-level? importance measures that take into account different failure modes of the component including common-cause failures (CCFs). In opening sections the roleof risk assessment in safety analysis of an NPP is introduced and discussion given of ?traditional?, mainly deterministic, design principles which have been established to assign a level of importance to a particular system, structure or component. This is followed by an overview of main risk importance measures for risk increase and risk decrease from current PRAs. Basic relations which exist among the measures are shown. Some of the current practical applications of risk importancemeasures from the field of NPP design, operation and regulation are discussed. The core of the monograph provides a discussion on theoreticalbackground and practical aspects of main risk importance measures at the level of ?component? as modeled in a PRA, starting from the simplest case, single basic event, and going toward more complexcases with multiple basic events and involvements in CCF groups. The intent is to express the component-level importance measures via theimportance measures and probabilities of the underlying single basic events, which are the inputs readily available from a PRA model andits results. Formulas are derived and discussed for some typical cases. The formulas and their results are demonstrated through some practicalexamples, done by means of a simplified PRA model developed in and run by RiskSpectrum? tool, which are presented in the appendices. The

  16. Relocation of radioactive residuals store: environment effects statement

    International Nuclear Information System (INIS)

    1984-11-01

    This Environment Effects Statement describes and assesses the likely environmental effects of the proposal to relocate the Health Commission's existing radioactive residuals store to a site within the established Dutson Downs waste disposal area, located 20 km south-east of Sale and 225 km east of Melbourne. The information presented demonstrates that the siting and construction of the proposed radioactive residuals store and the procedures to be adopted for the handling and storage of materials will not present an unacceptable risk to public health and safety, nor will it involve any significant adverse environmental effects

  17. Journal Afrika Statistika ISSN 0852-0305 Distortion risk measures ...

    African Journals Online (AJOL)

    la somme et sur la structure de dépendance des risques, représentée par une copule. ... Key words: Coherence; Dependence structure; Distortion function; Risk measure; Risk theory; insurance; Wang ..... Weighted risk capital allocations.

  18. Analysis of Residual Nuclide in a ACM and ACCT of 100-MeV proton beamline By measurement X-ray Spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong-Min; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    The proton beam is provides to users as various energy range from 20 MeV to 100 MeV. After protons generated from the ion source are accelerated to 100 MeV and irradiated to target through bending magnet and AC magnet. At this time, relatively high dose X-ray is emitted due to collision of proton and components of beamline. The generated X-ray is remaining after the accelerator is turned off and analyzing residual nuclides through the measurement of X-ray spectrum. Then identify the components that are the primary cause of residual nuclides are detected form the AC magnet(ACM) and associated components (ACCT). Analysis of the X-ray spectrum generated form the AC magnet(ACM) and AC current transformer(ACCT) of 100 MeV beamline according to the proton beam irradiation, most of the residual nuclides are identified it can be seen that emission in the stainless steel by beam loss.

  19. Importance measures for use in PRAs and risk management

    International Nuclear Information System (INIS)

    Schmidt, E.R.; Jamali, K.M.; Parry, G.W.; Gibbon, S.H.

    1985-01-01

    There are many quantities estimated in probabilistic risk assessments (PRAs) to index the level of plant safety. If the PRA is to be used as a risk management tool to assist in the safe operation of the plant, it is essential that those elements of the plant design and its mode of operation that have the greatest impact on plant safety be identified. These elements may be identified by performing importance calculations. There are certain decisions that must be made before the importance calculation is carried out. The first is the definition of the events for which importance is to be evaluated; that is, to what level of resolution the analysis is to be performed. The second decision that must be made--and the major subject of this paper--is the choice of importance measure. Many measures of importance have been proposed; this discussion is restricted to three: the risk achievement (or degradation) worth, the risk reduction worth, and criticality importance. In the paper these measures of importance are defined, their interrelationships are discussed, and a generalized importance measure is introduced. The use of these three measures is compared and their advantages and disadvantages are discussed

  20. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units.

    Science.gov (United States)

    Smith, Gordon Wg; Goldie, Frank; Long, Steven; Lappin, David F; Ramage, Gordon; Smith, Andrew J

    2011-01-10

    The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.

  1. Dermatologic radiotherapy and thyroid cancer. Dose measurements and risk quantification

    International Nuclear Information System (INIS)

    Goldschmidt, H.; Gorson, R.O.; Lassen, M.

    1983-01-01

    Thyroid doses for various dermatologic radiation techniques were measured with thermoluminescent dosimeters and ionization rate meters in an Alderson-Rando anthropomorphic phantom. The effects of changes in radiation quality and of the use or nonuse of treatment cones and thyroid shields were evaluated in detail. The results indicate that the potential risk of radiogenic thyroid cancer is very small when proper radiation protection measures are used. The probability of radiogenic thyroid cancer developing and the potential mortality risk were assessed quantitatively for each measurement. The quantification of radiation risks allows comparisons with risks of other therapeutic modalities and the common hazards of daily life

  2. Prognostic Implication of Functional Incomplete Revascularization and Residual Functional SYNTAX Score in Patients With Coronary Artery Disease.

    Science.gov (United States)

    Choi, Ki Hong; Lee, Joo Myung; Koo, Bon-Kwon; Nam, Chang-Wook; Shin, Eun-Seok; Doh, Joon-Hyung; Rhee, Tae-Min; Hwang, Doyeon; Park, Jonghanne; Zhang, Jinlong; Kim, Kyung-Jin; Hu, Xinyang; Wang, Jianan; Ye, Fei; Chen, Shaoliang; Yang, Junqing; Chen, Jiyan; Tanaka, Nobuhiro; Yokoi, Hiroyoshi; Matsuo, Hitoshi; Takashima, Hiroaki; Shiono, Yasutsugu; Akasaka, Takashi

    2018-02-12

    The aim of this study was to investigate the prognostic implication of functional incomplete revascularization (IR) and residual functional SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (rFSS) in comparison with 3-vessel fractional flow reserve (FFR) and residual SYNTAX score. IR is associated with poor clinical outcomes in patients who underwent percutaneous coronary intervention. A total of 385 patients who underwent 3-vessel FFR measurement after stent implantation were included in this study. The rFSS was defined as residual SYNTAX score measured only in vessels with FFR ≤0.8. The study population was divided into the functional IR group (rFSS ≥1) and the functional complete revascularization (CR) group (rFSS = 0). The primary outcome was major adverse cardiac events (MACEs; a composite of cardiac death, myocardial infarction, and ischemia-driven revascularization) at 2 years. Functional CR was achieved in 283 patients (73.5%). At 2-year follow-up, the functional IR group showed a significantly higher risk for MACEs (functional IR vs. CR, 14.6% vs. 4.2%; hazard ratio: 4.09; 95% confidence interval: 1.82 to 9.21; p system (rFSS) after stent implantation better discriminated the risk for adverse events than anatomic or physiological assessment alone. (Clinical Implication of 3-Vessel Fractional Flow Reserve [FFR]; NCT01621438). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Residual magnetic field in rotary machines; Campo magnetico residual en maquinas rotatorias

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez V, Esteban A; Apanco R, Marcelino [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2007-07-01

    The residual magnetism is a phenomenon in which the magnetic dipoles of a substance are oriented in a certain degree. On the other hand, when internal forces exist capable of aligning elementary magnetic dipoles of a material, a permanent magnet is obtained. Just as in a conductor or in a material, in the elements of a rotary electrical machine magnetic fields can be induced that produce a residual magnetism or magnetization. In the rotary electrical machines, the magnetization phenomenon causes serious problems, such as the generation of induced currents that propitiate the mechanical wear in bearings, collars, trunnions and inclusive in the shaft, by effects known as pitting, frosting and spark tracks, as well as erroneous readings in vibration and temperature sensors, that in some cases can cause the shut down of the machine. In this article are presented the general concepts on the residual magnetism in rotary electrical machines, the causes that originate it and the problems that arises, as well as the demagnetization of the components that have residual magnetic field. The results obtained by the area of Electrical Equipment of the Instituto de Investigaciones Electricas are revised, during the execution of activities related to the measurement and elimination of the residual magnetic field in rotary electrical machines. [Spanish] El magnetismo residual es un fenomeno en el que los dipolos magneticos de una sustancia se encuentran orientados en un grado determinado. Por otro lado, cuando existen fuerzas internas capaces de alinear los dipolos magneticos elementales de un material, se tiene un iman permanente. Al igual que en un conductor o un material, en los elementos de una maquina electrica rotatoria se pueden inducir campos magneticos que producen un magnetismo residual o magnetizacion. En las maquinas electricas rotatorias, el fenomeno de magnetizacion causa graves problemas, como la generacion de corrientes inducidas que propician el desgaste mecanico

  4. Quantity of residual thrombus after successful catheter-directed thrombolysis for iliofemoral deep venous thrombosis correlates with recurrence.

    Science.gov (United States)

    Aziz, F; Comerota, A J

    2012-08-01

    Iliofemoral deep venous thrombosis (IFDVT) is an independent risk factor for recurrent DVT. It has been observed that recurrent DVT correlates with residual thrombus. This study evaluates whether risk of recurrence is related to the amount of residual thrombus following catheter-directed thrombolysis (CDT) for IFDVT. Patients who underwent CDT for IFDVT had their degree of lysis quantified by a reader blind to the patients' long-term clinical outcome. Patients were classified into two groups, ≥50% and thrombus. Recurrence was defined as a symptomatic presentation with image verification of new or additional thrombus. A total of 75 patients underwent CDT for IFDVT. Median follow-up was 35.9 months. Sixty-eight patients (91%) had no evidence of recurrence and seven (9%) developed recurrence. Of the patients who had ≥50% (mean 80%) residual thrombus, 50% (4/8) experienced recurrence, but in those with thrombus, only 5% (3/67) had recurrent DVT (P = 0.0014). The burden of residual thrombus at completion of CDT correlates with the risk of DVT recurrence. Patients having CDT for IFDVT had a lower risk of recurrence than expected. Successful clearing of acute clot in IFDVT patients significantly reduces the recurrence risk compared to patients with a large residual thrombus burden. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Multi-Residue Analysis of Pesticide Residues in Crude Pollens by UPLC-MS/MS

    Directory of Open Access Journals (Sweden)

    Zhou Tong

    2016-12-01

    Full Text Available A multi-residue method for the determination of 54 pesticide residues in pollens has been developed and validated. The proposed method was applied to the analysis of 48 crude pollen samples collected from eight provinces of China. The recovery of analytes ranged from 60% to 136% with relative standard deviations (RSDs below 30%. Of the 54 targeted compounds, 19 pesticides were detected. The major detection rates of each compound were 77.1% for carbendazim, 58.3% for fenpropathrin, 56.3% for chlorpyrifos, 50.0% for fluvalinate, 31.3% for chlorbenzuron, and 29.2% for triadimefon in crude pollen samples. The maximum values of each pesticide were 4516 ng/g for carbendazim, 162.8 ng/g for fenpropathrin, 176.6 ng/g for chlorpyrifos, 316.2 ng/g for fluvalinate, 437.2 ng/g for chlorbenzuron, 79.00 ng/g for triadimefon, and so on. This study provides basis for the research on the risks to honeybee health.

  6. Dependence of magnetic permeability on residual stresses in alloyed steels

    Directory of Open Access Journals (Sweden)

    E. Hristoforou

    2018-04-01

    Full Text Available A method for the monitoring of residual stress distribution in steels has been developed based on non-destructive surface magnetic permeability measurements. In order to investigate the potential utilization of the magnetic method in evaluating residual stresses, the magnetic calibration curves of various ferromagnetic alloyed steels’ grade (AISI 4140, TRIP and Duplex were examined. X-Ray diffraction technique was used for determining surface residual stress values. The overall measurement results have shown that the residual stress determined by the magnetic method was in good agreement with the diffraction results. Further experimental investigations are required to validate the preliminary results and to verify the presence of a unique normalized magnetic stress calibration curve.

  7. Dependence of magnetic permeability on residual stresses in alloyed steels

    Science.gov (United States)

    Hristoforou, E.; Ktena, A.; Vourna, P.; Argiris, K.

    2018-04-01

    A method for the monitoring of residual stress distribution in steels has been developed based on non-destructive surface magnetic permeability measurements. In order to investigate the potential utilization of the magnetic method in evaluating residual stresses, the magnetic calibration curves of various ferromagnetic alloyed steels' grade (AISI 4140, TRIP and Duplex) were examined. X-Ray diffraction technique was used for determining surface residual stress values. The overall measurement results have shown that the residual stress determined by the magnetic method was in good agreement with the diffraction results. Further experimental investigations are required to validate the preliminary results and to verify the presence of a unique normalized magnetic stress calibration curve.

  8. Use of risk importance measures in maintenance prioritization

    International Nuclear Information System (INIS)

    Dubreil Chambardel, A.; Ardorino, F.; Mauger, P.

    1997-01-01

    A RCM method has been developed at EDF since 1990 to optimize maintenance through a prioritization of resources for equipment that are important in terms of safety, availability and maintenance costs. In 1994, the Nuclear Power Plant Operations Division decided to apply this method to the most important systems of the French PWRs. About 50 systems are in the scope of the RCM. Those that have a role in safety were ranked depending on their contribution to the risk of core melt provided by PSAs. The RCM studies on the 20 most important to safety systems are performed by the Nuclear Power Plant Operations division, the other 30 systems are studied on sites. The RCM study consists first in the research of equipment and failures modes significant to safety, availability or maintenance costs and the evaluation of the performance of those equipment. Those studies lead to the distinction of equipment and failure modes that are critical or non critical to safety, availability and costs. The last part of the study consists in optimizing maintenance on those equipment. In this process, risk measures are used to help defining equipment and failure modes critical to safety. This is done by calculation of risk importance measures provided by PSAs. We explain in this paper which measures of risk have been defined, how PSAs allow calculation of those measures, and how we used those results in the RCM studies we processed. We give also extensions of the use of those measures in the process of defining optimized maintenance tasks. After having defined a RCM method for the French PWRs, the Nuclear Power plant Operations Division decided to start a generalized program of maintenance optimization for the most important systems. The three criteria on which the method relies are: safety, unit availability and maintenance costs. We present here the safety aspect of the method and more precisely these of risk importance measures in the RCM process. (author)

  9. Assessment of radon-induced health risk for occupants of a house built on uranium ore residue

    International Nuclear Information System (INIS)

    Clero, E.; Marie, L.; Challeton-De Vathaire, C.; Laurier, D.; Rannou, A.

    2016-01-01

    At the request of French public authorities, the Institute of Radiological Protection and Nuclear Safety has assessed the radiological situation of a house built on uranium ore residues in Haute-Vienne and the health risks induced from exposure to radon for all occupants. Classified as a lung carcinogen by the World Health Organization, radon is a proven cause of lung cancer in case of regular inhalation over a long period, and the risk increases with cumulative exposure. Radon exposure was reconstructed for various standard profiles of house occupancy. A risk model derived from a European epidemiological study was used to calculate the lifetime probability of death from lung cancer according to these standard profiles. Risk assessment of the occupants of the house highlighted the following main findings. For a resident school child having been exposed to radon from birth to the age of 7, the lifetime relative risk (LRR) was estimated at 5. For last adult and young adult residents having lived more than 10 years in the house, the probability of death from lung cancer was in the same order of magnitude as that of a regular cigarette smoker, with a LRR from 10 to 13 and a lifetime probability of death from lung cancer between 3 and 4%. If these individuals smoked regularly, in addition to being exposed to radon, this probability would be between 6 and 32% (supposing an additive or multiplicative interaction). For former occupants (non-smokers) having been exposed 10 years during childhood, the LRR was two-fold lower. For children having been in day care in the house, the increased probability of death from lung cancer was low, with a LRR lower than 2. Supposing, as in adults, that the risk decreases beyond 30 years after the end of radon exposure, the increase was almost zero for former occupants exposed during childhood and during day care, with a LRR close to 1. (authors)

  10. Performance, body measurements, carcass and cut yields, and meat quality in lambs fed residues from processing agroindustry of fruits

    Directory of Open Access Journals (Sweden)

    Darcilene Maria de Figueiredo

    2015-02-01

    Full Text Available This research was conducted with the objective to evaluate the use of residue dry matter (DM from pineapple (Ananas comosus L., banana (Musa sp., mango (Mangifera indica and passion fruit (Passiflora spp. in feeding of the feedlot on productive performance, carcass yield and qualitative and quantitative characteristics of meat. Twenty-five crossbred lamps with Santa Inês breed and mixed breed were used. The treatments consisted of the replacement of 75% of sorghum silage by respective residue DM, whereas in the control treatment forage had only sorghum silage the diets had a houghageto- concentrate ratio of 40:60 interns of DM being isonitrogenous and isoenergetics. The animals were slaughtered at 32 kg liveweight. Before slaughter were obtained biometric measurements, after the same, was performed the hot carcasses weight and morphometric measurements. After 24 hours in a cold chamber at 4 ° C, was determined the cold carcass weight and yield calculation. The left half carcass was divided into five sections: neck, shoulder, shank, rib and loin, by performing the calculation of income cuts. Analyses meat quality such as pH, color (L, a, b, chroma and Ho, by cooking weight loss, water retention capacity and shear strength were carried out in the Longissimus dorsi sample. The completely randomized design was adapted. The data were interpreted using analysis of variance with the test a Tukey 5% probability. There was no effect of diet (P> 0.05 according to the parameters: growth performance, body measurements, and meat quality of lambs. There was also no effect of the diets (P> 0.05 on the loin eye area assuming that carcasses remained similar muscularity important fact to market acceptance standard. It is concluded that replacing up to 75% of sorghum silage by residues fruit (pineapple, banana, mango and passion fruit in lambs feeding becomes feasible not to change the productive performance, body measurements, yields carcass and cuts and meat

  11. Front-line intraperitoneal versus intravenous chemotherapy in stage III-IV epithelial ovarian, tubal, and peritoneal cancer with minimal residual disease: a competing risk analysis.

    Science.gov (United States)

    Chang, Yen-Hou; Li, Wai-Hou; Chang, Yi; Peng, Chia-Wen; Cheng, Ching-Hsuan; Chang, Wei-Pin; Chuang, Chi-Mu

    2016-03-17

    In the analysis of survival data for cancer patients, the problem of competing risks is often ignored. Competing risks have been recognized as a special case of time-to-event analysis. The conventional techniques for time-to-event analysis applied in the presence of competing risks often give biased or uninterpretable results. Using a prospectively collected administrative health care database in a single institution, we identified patients diagnosed with stage III or IV primary epithelial ovarian, tubal, and peritoneal cancers with minimal residual disease after primary cytoreductive surgery between 1995 and 2012. Here, we sought to evaluate whether intraperitoneal chemotherapy outperforms intravenous chemotherapy in the presence of competing risks. Unadjusted and multivariable subdistribution hazards models were applied to this database with two types of competing risks (cancer-specific mortality and other-cause mortality) coded to measure the relative effects of intraperitoneal chemotherapy. A total of 1263 patients were recruited as the initial cohort. After propensity score matching, 381 patients in each arm entered into final competing risk analysis. Cumulative incidence estimates for cancer-specific mortality were statistically significantly lower (p = 0.017, Gray test) in patients receiving intraperitoneal chemotherapy (5-year estimates, 34.5%; 95% confidence interval [CI], 29.5-39.6%, and 10-year estimates, 60.7%; 95% CI, 52.2-68.0%) versus intravenous chemotherapy (5-year estimates, 41.3%; 95% CI, 36.2-46.3%, and 10-year estimates, 67.5%, 95% CI, 61.6-72.7%). In subdistribution hazards analysis, for cancer-specific mortality, intraperitoneal chemotherapy outperforms intravenous chemotherapy (Subdistribution hazard ratio, 0.82; 95% CI, 0.70-0.96) after correcting other covariates. In conclusion, results from this comparative effectiveness study provide supportive evidence for previous published randomized trials that intraperitoneal chemotherapy

  12. Residual-stress distributions near stainless steel butt weldments

    International Nuclear Information System (INIS)

    Elligson, W.A.; Shack, W.J.

    1978-01-01

    Concern for the integrity of stainless steel butt-weldments in boiling-water-reactor (BWR) piping systems has stimulated study of the conditions that cause stress corrosion cracking (SCC) in the heat-affected zones (HAZ) of the weldments. It is generally agreed that a high stress exceeding the initial yield strength is one of the essential elements for crack initiation. Since design procedures usually ensure that load stresses are below initial yield, the source of the high stresses necessary to produce SCC is thought to be the residual stresses due to welding. To examine the level of residual stresses in the weldments of interest, bulk residual stresses were measured on 100 mm (4-in.) and 254 mm (10-in.) diameter Schedule 80 piping weldments using strain relief techniques. Both laboratory welded specimens and field welded specimens from reactors in service were studied. Axial bulk residual stress distributions were obtained at 45 0 intervals around the circumference. At each azimuthal position, the residual stresses were measured at seven axial positions: on the weld centerline and 13, 20, and 25 mm on either side of the weld centerline on both the inside and outside surfaces

  13. Pesticide residue quantification analysis by hyperspectral imaging sensors

    Science.gov (United States)

    Liao, Yuan-Hsun; Lo, Wei-Sheng; Guo, Horng-Yuh; Kao, Ching-Hua; Chou, Tau-Meu; Chen, Junne-Jih; Wen, Chia-Hsien; Lin, Chinsu; Chen, Hsian-Min; Ouyang, Yen-Chieh; Wu, Chao-Cheng; Chen, Shih-Yu; Chang, Chein-I.

    2015-05-01

    Pesticide residue detection in agriculture crops is a challenging issue and is even more difficult to quantify pesticide residue resident in agriculture produces and fruits. This paper conducts a series of base-line experiments which are particularly designed for three specific pesticides commonly used in Taiwan. The materials used for experiments are single leaves of vegetable produces which are being contaminated by various amount of concentration of pesticides. Two sensors are used to collected data. One is Fourier Transform Infrared (FTIR) spectroscopy. The other is a hyperspectral sensor, called Geophysical and Environmental Research (GER) 2600 spectroradiometer which is a batteryoperated field portable spectroradiometer with full real-time data acquisition from 350 nm to 2500 nm. In order to quantify data with different levels of pesticide residue concentration, several measures for spectral discrimination are developed. Mores specifically, new measures for calculating relative power between two sensors are particularly designed to be able to evaluate effectiveness of each of sensors in quantifying the used pesticide residues. The experimental results show that the GER is a better sensor than FTIR in the sense of pesticide residue quantification.

  14. Implementation and Development of the Incremental Hole Drilling Method for the Measurement of Residual Stress in Thermal Spray Coatings

    Science.gov (United States)

    Valente, T.; Bartuli, C.; Sebastiani, M.; Loreto, A.

    2005-12-01

    The experimental measurement of residual stresses originating within thick coatings deposited by thermal spray on solid substrates plays a role of fundamental relevance in the preliminary stages of coating design and process parameters optimization. The hole-drilling method is a versatile and widely used technique for the experimental determination of residual stress in the most superficial layers of a solid body. The consolidated procedure, however, can only be implemented for metallic bulk materials or for homogeneous, linear elastic, and isotropic materials. The main objective of the present investigation was to adapt the experimental method to the measurement of stress fields built up in ceramic coatings/metallic bonding layers structures manufactured by plasma spray deposition. A finite element calculation procedure was implemented to identify the calibration coefficients necessary to take into account the elastic modulus discontinuities that characterize the layered structure through its thickness. Experimental adjustments were then proposed to overcome problems related to the low thermal conductivity of the coatings. The number of calculation steps and experimental drilling steps were finally optimized.

  15. Determination of Pesticides Residues in Cucumbers Grown in Greenhouse and the Effect of Some Procedures on Their Residues.

    Science.gov (United States)

    Leili, Mostafa; Pirmoghani, Amin; Samadi, Mohammad Taghi; Shokoohi, Reza; Roshanaei, Ghodratollah; Poormohammadi, Ali

    2016-11-01

    The objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. The effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. Ten active greenhouses that produce cucumber were randomly selected. Ethion and imidacloprid as the most widely used pesticides were measured in cucumber samples of studied greenhouses. Moreover, the effect of storing, washing, and peeling as simple processing procedures on both ethion and imidacloprid residues were investigated. One hour after pesticide application; the maximum residue levels (MRLs) of ethion and imidacloprid were higher than that of Codex standard level. One day after pesticide application, the levels of pesticides were decreased about 35 and 31% for ethion and imidacloprid, respectively, which still were higher than the MRL. Washing procedure led to about 51 and 42.5% loss in ethion and imidacloprid residues, respectively. Peeling procedure also led to highest loss of 93.4 and 63.7% in ethion and imidacloprid residues, respectively. The recovery for both target analytes was in the range between 88 and 102%. The residue values in collected samples one hour after pesticides application were higher than standard value. The storing, washing, and peeling procedures lead to the decrease of pesticide residues in greenhouse cucumbers. Among them, the peeling procedure has the greatest impact on residual reduction. Therefore, these procedures can be used as simple and effective processing techniques for reducing and removing pesticides from greenhouse products before their consumption.

  16. ESTIMATION OF THE BURDEN OF PESTICIDE RESIDUES IN SLOVAK POPULATION

    Directory of Open Access Journals (Sweden)

    Jozef Sokol

    2010-07-01

    Full Text Available Pesticides used in the agriculture have to be applied according to the requirements of good agricultural practice and appropriate law. Pesticides leave detectable residues in agricultural crops, raw materials and ecosystem components. Pesticides reach the human population through the food chain. Information on the type and concentration of pesticide residues in food is in Slovakia collected trough the monitoring programs. Health risks associated with pesticides contaminants in human nutrition are very important and are recently studied by several expert groups. Prerequisite programs are necessary to protect public health. Risk analysis and monitoring of the population burden by pesticide contaminants have to be performed in expert level. The general strategy for assessment of toxicity of pesticides is listed by the World health Organisation. Scientific risk assessment is the basis for taking action and making the legislation at national and European community level.doi:10.5219/69

  17. An analytical method on the surface residual stress for the cutting tool orientation

    Science.gov (United States)

    Li, Yueen; Zhao, Jun; Wang, Wei

    2010-03-01

    The residual stress is measured by choosing 8 kinds orientations on cutting the H13 dies steel on the HSM in the experiment of this paper. The measured data shows on that the residual stress exists periodicity for the different rake angle (β) and side rake angle (θ) parameters, further study find that the cutting tool orientations have closed relationship with the residual stresses, and for the original of the machined residual stress on the surface from the cutting force and the axial force, it can be gained the simply model of tool-workpiece force, using the model it can be deduced the residual stress model, which is feasible to calculate the size of residual stress. And for almost all the measured residual stresses are compressed stress, the compressed stress size and the direction could be confirmed by the input data for the H13 on HSM. As the result, the residual stress model is the key for optimization of rake angle (β) and side rake angle (θ) in theory, using the theory the more cutting mechanism can be expressed.

  18. Comparison of Some Mechanical and Physical Methods for Measurement of Residual Stresses in Brush-Plated Nickel Hardened Gold and Silver Coatings

    Directory of Open Access Journals (Sweden)

    Harri LILLE

    2016-05-01

    Full Text Available Hard gold and silver are applied in coating owing to their high hardness, good wear and corrosion resistance for engineering application (e.g. on generators slip rings, sliding contacts and small machine parts and are typically plated on copper (mostly, brass and bronze. The studied nickel-hardened gold and silver coatings were brush plated on open thin-walled copper ring substrates. Residual stresses in the coatings were calculated from the curvature changes of the substrates. Biaxial intrinsic residual stresses were also determined by nanoindentation testing and by the X-ray technique. The values of the residual stresses represented tensile stresses and when determined by the techniques used they were comparable within a maximum limit of measurement uncertainty. These stresses relax; the dependence of relaxation time was approximated by a linear-fractional function.DOI: http://dx.doi.org/10.5755/j01.ms.22.1.7439

  19. Formation of non-extractable pesticide residues: observations on compound differences, measurement and regulatory issues

    Energy Technology Data Exchange (ETDEWEB)

    Mordaunt, Catriona J.; Gevao, Bondi; Jones, Kevin C.; Semple, Kirk T

    2005-01-01

    Six major use pesticides (Atrazine, Dicamba, Isoproturon, Lindane, Paraquat and Trifluralin) with differing physico-chemical properties were evaluated for the significance of 'bound' or non extractable residue formation. Investigations were carried out in purpose-built microcosms where mineralization, volatilisation, 'soil water' extractable and organic solvent extractable residues could be quantified. Extractable residues were defined as those accessible by sequential extraction where the solvent used became increasingly non-polar. Dichloromethane was the 'harshest' solvent used at the end of the sequential extraction procedure. {sup 14}C-labelled volatilised and {sup 14}CO{sub 2} fractions were trapped on exit from the microcosm. The pesticides were categorised into 3 classes based on their behaviour. (i) Type A (Atrazine, Lindane and Trifluralin) in which ring degradation was limited as was the formation of non-extractable residues; the remainder of the {sup 14}C-activity was found in the extractable fraction. (ii) Type B (Dicamba and Isoproturon) in which approximately 25% of the {sup 14}C-activity was mineralised and a large portion was found in the non-extractable fraction after 91 days. Finally, Type C (Paraquat) in which almost all of the {sup 14}C-activity was quickly incorporated into the non-extractable fraction. The implications of the data are discussed, with respect to the variability and significance of regulatory aspects of non-extractable residues.

  20. Formation of non-extractable pesticide residues: observations on compound differences, measurement and regulatory issues

    International Nuclear Information System (INIS)

    Mordaunt, Catriona J.; Gevao, Bondi; Jones, Kevin C.; Semple, Kirk T.

    2005-01-01

    Six major use pesticides (Atrazine, Dicamba, Isoproturon, Lindane, Paraquat and Trifluralin) with differing physico-chemical properties were evaluated for the significance of 'bound' or non extractable residue formation. Investigations were carried out in purpose-built microcosms where mineralization, volatilisation, 'soil water' extractable and organic solvent extractable residues could be quantified. Extractable residues were defined as those accessible by sequential extraction where the solvent used became increasingly non-polar. Dichloromethane was the 'harshest' solvent used at the end of the sequential extraction procedure. 14 C-labelled volatilised and 14 CO 2 fractions were trapped on exit from the microcosm. The pesticides were categorised into 3 classes based on their behaviour. (i) Type A (Atrazine, Lindane and Trifluralin) in which ring degradation was limited as was the formation of non-extractable residues; the remainder of the 14 C-activity was found in the extractable fraction. (ii) Type B (Dicamba and Isoproturon) in which approximately 25% of the 14 C-activity was mineralised and a large portion was found in the non-extractable fraction after 91 days. Finally, Type C (Paraquat) in which almost all of the 14 C-activity was quickly incorporated into the non-extractable fraction. The implications of the data are discussed, with respect to the variability and significance of regulatory aspects of non-extractable residues

  1. Improving measurement of injection drug risk behavior using item response theory.

    Science.gov (United States)

    Janulis, Patrick

    2014-03-01

    Recent research highlights the multiple steps to preparing and injecting drugs and the resultant viral threats faced by drug users. This research suggests that more sensitive measurement of injection drug HIV risk behavior is required. In addition, growing evidence suggests there are gender differences in injection risk behavior. However, the potential for differential item functioning between genders has not been explored. To explore item response theory as an improved measurement modeling technique that provides empirically justified scaling of injection risk behavior and to examine for potential gender-based differential item functioning. Data is used from three studies in the National Institute on Drug Abuse's Criminal Justice Drug Abuse Treatment Studies. A two-parameter item response theory model was used to scale injection risk behavior and logistic regression was used to examine for differential item functioning. Item fit statistics suggest that item response theory can be used to scale injection risk behavior and these models can provide more sensitive estimates of risk behavior. Additionally, gender-based differential item functioning is present in the current data. Improved measurement of injection risk behavior using item response theory should be encouraged as these models provide increased congruence between construct measurement and the complexity of injection-related HIV risk. Suggestions are made to further improve injection risk behavior measurement. Furthermore, results suggest direct comparisons of composite scores between males and females may be misleading and future work should account for differential item functioning before comparing levels of injection risk behavior.

  2. Washing effects of limonene on pesticide residues in green peppers.

    Science.gov (United States)

    Lu, Hai-Yan; Shen, Yan; Sun, Xing; Zhu, Hong; Liu, Xian-Jin

    2013-09-01

    The presence of pesticide residues in food has caused much concern. The low health risks and environmental impacts of limonene make it a very interesting solvent for use in green chemistry. Washing effects of limonene on pesticide residues of methyl chlorpyrifos, chlorothalonil, chlorpyrifos, fenpropathrin and deltamethrin were investigated in green pepper. Results showed that washing with a low concentration of limonene for 5 min (where LOQ is limit of quantitation) caused 53.67%, limonene for 10 min produced 55.90%, limonene for 5 min was the optimal treatment for elimination of pesticide residues in green pepper, considering effect and treatment time as well as cost. © 2013 Society of Chemical Industry.

  3. Cavity pressure/residual stress measurements from the Non-Proliferation Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Heinle, R.A.; Hudson, B.C. [Lawrence Livermore National Lab., CA (United States); Hatch, M.A. Jr.

    1994-12-31

    The Lawrence Livermore National Laboratory planned and conducted experiments on the Non-Proliferation Experiment to determine post-detonation gas pressure inside the explosive cavity and the residual rock stress in the region immediately outside the cavity. Before detonation there was significant concern that steam and detonation products would create very high temperatures and pressure in the blast cavity that would exist for weeks and months after firing. This could constitute a safety hazard to personnel re-entering the tunnel. Consequently the Lawrence Livermore National Laboratory was asked to field its Cavity Pressure/Residual stress monitor system on the Non-Proliferation Experiment. We obtained experimental data for the first 600 ms after the explosion and again several weeks after detonation upon tunnel re-entry. We recorded early-time cavity pressure of about 8.3 MPa. In addition we believe that the ends of our sensor hoses were subjected to an ambient driving pressure of about 0.5 MPa (absolute) that persisted until at least three weeks after zero time.

  4. Residual stresses in a cast iron automotive brake disc rotor

    International Nuclear Information System (INIS)

    Ripley, Maurice I.; Kirstein, Oliver

    2006-01-01

    Runout, and consequent juddering and pulsation through the brake pedal, is a multi-million dollar per year warranty problem for car manufacturers. There is some suspicion that the runout can be caused by relaxation of residual casting stresses when the disc is overheated during severe-braking episodes. We report here neutron-diffraction measurements of the levels and distribution of residual strains in a used cast iron brake disc rotor. The difficulties of measuring stresses in grey cast iron are outlined and three-dimensional residual-strain distributions are presented and their possible effects discussed

  5. Summary report of phase I residual holdup measurements for a mixed oxide fuel fabrication facility

    International Nuclear Information System (INIS)

    Woodsum, H.C.

    1978-03-01

    Metal surface-powder adherence tests showed that the average mean values for direct impingement was 60 to 80 g/ft 2 , whereas the average mean values of the colloidal samples were 0.2 to 2.5 g/ft 2 . Thus, it is advantageous to design powder processing equipment to reduce direct impingement wherever possible. Holdup of powder appears to be relatively independent of the surface material or finish, and it is reduced significantly by low-frequency vibration of the surface. Under colloidal conditions, ThO 2 produces more residual material than UO 2 and is preferentially deposited from a UO 2 --ThO 2 blend. Pure ThO 2 and high enrichment blends of ThO 2 in UO 2 are expected to produce a significant, persistent electrostatic charge, thus increasing residual holdup. Residual holdup in the clean scrap recovery system (CSRS) could be reduced by 25%. Comparison of CSRS holdup and powder adherence-metal surface data indicated that the areal density of residual material (40 g/ft 2 ) was considerably higher than for colloidal suspension ( 2 ). Steady-state residual holdup factor for sintered-metal filters was 13 g/ft 2 of filter surface area under optimum conditions. During the pellet grinding tests, residual material built up in the system at rate of about 100 g/h to an estimated limit of 1.4 kg, primarily within the particle collector shroud. During dry grinding, 97% of this residue was contained within the shroud, and during wet grinding only 50% was contained in the shroud owing to inertial effects of the rotating wheel and water coolant

  6. Elevated post-void residual volume in a geriatric post-hip fracture assessment in women-associated factors and risk of mortality.

    Science.gov (United States)

    Nuotio, Maria S; Luukkaala, Tiina; Tammela, Teuvo

    2018-04-09

    Multiple factors contribute to elevated post-void residual urine volumes (PVR), but they may indicate detrusor underactivity (DU), especially in older women. The aim here was to examine factors associated with and prognostic significance of elevated PVR in a geriatric post-hip fracture assessment in a female population. Consecutive female hip fracture patients (n = 409) aged 65 years and older were included. PVR was measured by bladder scanner. PVR of 160 ml or more was deemed elevated. Age-adjusted univariate logistic regression analyses were conducted to examine the association of the domains of the comprehensive geriatric assessment (CGA) with elevated PVR. Cox proportional hazards model was used to determine the age-adjusted association of an elevated PVR with 1-year mortality. Of the patients, 64 (15.6%) had elevated PVR. Having urinary or fecal incontinence, difficulties in physical activities of daily living, malnutrition, poor performance on Timed Up and Go and Elderly Mobility Scale were significantly associated with elevated PVR. Difficulties in instrumental activities of daily living, renal dysfunction, constipation, polypharmacy, nocturia, cognitive impairment and depressive mood were not associated with elevated PVR. Elevated PVR significantly increased the risk of mortality 1 year post hip fracture. Elevated PVR is relatively common in older female hip fracture patients and associated with physical functioning, malnutrition and risk of mortality. Even though a causal relationship cannot be confirmed, the findings may suggest a relationship between DU and physical frailty. PVR deserves to be included in the CGA of frail older patients including women.

  7. Evaporation residue excitation function measurement for 19F + 194,198Pt reactions

    International Nuclear Information System (INIS)

    Singh, Varinderjit; Behera, B.R.; Kaur, Maninder

    2012-01-01

    Nuclear dissipation is one of the active fields in the present day nuclear physics research. Experimental signatures for dissipation are observed through large excess in pre-fission neutrons, γ-ray multiplicities from the compound nucleus, giant dipole resonance (GDR) γ-rays, light charged particles and evaporation residues in comparison to standard statistical model, for the heavy-ion induced fusion-fission or fusion-evaporation reactions (ERs). From the analysis of a large set of experimental data, it is well established that there exists a large dissipation at nuclear temperature above 1 MeV. But most of these probes are not sensitive to the dissipation within saddle. The ER cross-section is a probe which is sensitive to dissipation within the saddle point. Hence, the study of ER cross-section can be helpful in estimating the dissipation effects inside the saddle point. Also the other motivation for these measurements is to see the effect of shell closure on dissipation. With this motivation the evaporation cross-sections for 19 F + 194,198 Pt are measured at beam energy of 101 to 137.3 MeV. Of the above systems 19 F + 194 Pt populates 213 Fr (N = 126) shell closed compound nucleus (CN) whereas, other system populate 217 Fr (N = 130) non-shell closed CN

  8. In situ chemical composition measurement of individual cloud residue particles at a mountain site, southern China

    Directory of Open Access Journals (Sweden)

    Q. Lin

    2017-07-01

    Full Text Available To investigate how atmospheric aerosol particles interact with chemical composition of cloud droplets, a ground-based counterflow virtual impactor (GCVI coupled with a real-time single-particle aerosol mass spectrometer (SPAMS was used to assess the chemical composition and mixing state of individual cloud residue particles in the Nanling Mountains (1690 m a. s. l. , southern China, in January 2016. The cloud residues were classified into nine particle types: aged elemental carbon (EC, potassium-rich (K-rich, amine, dust, Pb, Fe, organic carbon (OC, sodium-rich (Na-rich and Other. The largest fraction of the total cloud residues was the aged EC type (49.3 %, followed by the K-rich type (33.9 %. Abundant aged EC cloud residues that mixed internally with inorganic salts were found in air masses from northerly polluted areas. The number fraction (NF of the K-rich cloud residues increased within southwesterly air masses from fire activities in Southeast Asia. When air masses changed from northerly polluted areas to southwesterly ocean and livestock areas, the amine particles increased from 0.2 to 15.1 % of the total cloud residues. The dust, Fe, Pb, Na-rich and OC particle types had a low contribution (0.5–4.1 % to the total cloud residues. Higher fraction of nitrate (88–89 % was found in the dust and Na-rich cloud residues relative to sulfate (41–42 % and ammonium (15–23 %. Higher intensity of nitrate was found in the cloud residues relative to the ambient particles. Compared with nonactivated particles, nitrate intensity decreased in all cloud residues except for dust type. To our knowledge, this study is the first report on in situ observation of the chemical composition and mixing state of individual cloud residue particles in China.

  9. Advancing environmental toxicology through chemical dosimetry: External exposures versus tissue residues

    Science.gov (United States)

    McCarty, L.S.; Landrum, P.F.; Luoma, S.N.; Meador, J.P.; Merten, A.A.; Shephard, B.K.; van Wezelzz, A.P.

    2011-01-01

    The tissue residue dose concept has been used, although in a limited manner, in environmental toxicology for more than 100 y. This review outlines the history of this approach and the technical background for organic chemicals and metals. Although the toxicity of both can be explained in tissue residue terms, the relationship between external exposure concentration, body and/or tissues dose surrogates, and the effective internal dose at the sites of toxic action tends to be more complex for metals. Various issues and current limitations related to research and regulatory applications are also examined. It is clear that the tissue residue approach (TRA) should be an integral component in future efforts to enhance the generation, understanding, and utility of toxicity testing data, both in the laboratory and in the field. To accomplish these goals, several key areas need to be addressed: 1) development of a risk-based interpretive framework linking toxicology and ecology at multiple levels of biological organization and incorporating organism-based dose metrics; 2) a broadly applicable, generally accepted classification scheme for modes/mechanisms of toxic action with explicit consideration of residue information to improve both single chemical and mixture toxicity data interpretation and regulatory risk assessment; 3) toxicity testing protocols updated to ensure collection of adequate residue information, along with toxicokinetics and toxicodynamics information, based on explicitly defined toxicological models accompanied by toxicological model validation; 4) continued development of residueeffect databases is needed ensure their ongoing utility; and 5) regulatory guidance incorporating residue-based testing and interpretation approaches, essential in various jurisdictions. ??:2010 SETAC.

  10. Risk management considerations for seismic upgrading of an older facility for short-term residue stabilization

    International Nuclear Information System (INIS)

    Additon, S.L.; Peregoy, W.L.; Foppe, T.L.

    1999-01-01

    Building 707 and its addition, Building 707A, were selected, after the production mission of Rocky Flats was terminated a few years ago, to stabilize many of the plutonium residues remaining at the site by 2002. The facility had undergone substantial safety improvements to its safety systems and conduct of operations for resumption of plutonium operations in the early 1990s and appeared ideally suited for this new mission to support accelerated Site closure. During development of a new authorization basis, a seismic evaluation was performed. This evaluation addressed an unanalyzed expansion joint and suspect connection details for the precast concrete tilt-up construction and concluded that the seismic capacity of the facility is less than half of that determined by previous analysis. Further, potential seismic interaction was identified between a collapsing Building 707 and the seismically upgraded Building 707A, possibly causing the partial collapse of the latter. Both the operating contractor and the Department of Energy sought a sound technical basis for deciding how to proceed. This paper addresses the risks of the as-is facility and possible benefits of upgrades to support a decision on whether to upgrade the seismic capacity of Building 707, accept the risk of the as-is facility for its short remaining mission, or relocate critical stabilization missions. The paper also addresses the Department of Energy's policy on natural phenomena

  11. Residual stress analysis in carbon fiber-reinforced SiC ceramics

    International Nuclear Information System (INIS)

    Broda, M.

    1998-01-01

    Systematic residual stress analyses are reported, carried out in long-fiber reinforced SiC ceramics. The laminated C fiber /SiC matrix specimens used were prepared by polymer pyrolysis, and the structural component specimens used are industrial products. Various diffraction methods have been applied for non-destructive evaluation of residual stress fields, so as to completely detect the residual stresses and their distribution in the specimens. The residual stress fields at the surface (μm) have been measured using characteristic X-radiation and applying the sin 2 ψ method as well as the scatter vector method. For residual stress field analysis in the mass volume (cm), neutron diffraction has been applied. The stress fields in the fiber layers (approx. 250μm) have been measured as a function of their location within the laminated composite by using an energy-dispersive method and synchrotron radiation. By means of the systematic, process-accompanying residual stress and phase analyses, conclusions can be drawn as to possible approaches for optimization of fabrication parameters. (orig./CB) [de

  12. Isotopic tracer aided studies of fenvalerate residues in stored rice

    International Nuclear Information System (INIS)

    Varca, L.M.; Sanchez, T.E.; Magallona, E.D.

    1990-01-01

    Following application of 14 C-fenvalerate to milled rice and paddy rice at a concentration of 0.33 mg/kg, only insignificant losses were measured after 9 months. Distribution patterns in surface, methanol extractable and bound residues were studied. Paddy rice contained less extractable residues than milled rice, with the major part being found in the husk. Bound residues in both milled and paddy rice decreased also with length of storage; as much as 30% was found as bound residues after nine months. Cooking reduced the insecticide residues in milled rice by 33-40% and residues in paddy rice by 58%. (author). 8 refs, 1 fig., 4 tabs

  13. Residual Risk Report to Congress 1999

    Science.gov (United States)

    This report is a description of the methods and general framework that EPA uses to assess the public health and environmental risk which may remain after implementation of air toxics emissions standards required under section 112(d) of the Clean Air Act.

  14. Residual stress analysis of drive shafts after induction hardening

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, Guilherme Vieira Braga; Rocha, Alexandre da Silva; Nunes, Rafael Menezes, E-mail: lemos_gl@yahoo.com.br [Universidade Federal do Rio Grande do Sul (UFRS), Porto Algre, RS (Brazil); Hirsch, Thomas Karl [Stiftung Institut für Werkstofftechnik (IWT), Bremen (Germany)

    2014-08-15

    Typically, for automotive shafts, shape distortion manifests itself in most cases after the induction hardening by an effect known as bending. The distortion results in a boost of costs, especially due to machining parts in the hardened state to fabricate its final tolerances. In the present study, residual stress measurements were carried out on automotive drive shafts made of DIN 38B3 steel. The samples were selected in consequence of their different distortion properties by an industrial manufacturing line. One tested shaft was straightened, because of the considerable dimensional variation and the other one not. Firstly, the residual stress measurements were carried out by using a portable diffractometer, in order to avoid cutting the shafts and evaluate the original state of the stresses, and afterwards a more detailed analysis was realized by a conventional stationary diffractometer. The obtained results presented an overview of the surface residual stress profiles after induction hardening and displayed the influence of the straightening process on the redistribution of residual stresses. They also indicated that the effects of the straightening in the residual stresses cannot be neglected. (author)

  15. Liquidity Risk meets Economic Capital and RAROC. A framework for measuring liquidity risk in banks.

    NARCIS (Netherlands)

    Loebnitz, K.

    2011-01-01

    Liquidity risk is a crucial and inherent feature of the business model of banks. While banks and regulators use sophisticated mathematical methods to measure a bank's solvency risk, they use relatively simple tools for a bank's liquidity risk such as coverage ratios, sensitivity analyses, and

  16. On the interplay between distortion, mean value and Haezendonck-Goovaerts risk measures

    NARCIS (Netherlands)

    Goovaerts, M.J.; Linders, D.; van Weert, K.; Tank, F.

    2012-01-01

    In the actuarial research, distortion, mean value and Haezendonck-Goovaerts risk measures are concepts that are usually treated separately. In this paper we indicate and characterize the relation between these different risk measures, as well as their relation to convex risk measures. While it is

  17. Do insurers respond to risk adjustment? A long-term, nationwide analysis from Switzerland.

    Science.gov (United States)

    von Wyl, Viktor; Beck, Konstantin

    2016-03-01

    Community rating in social health insurance calls for risk adjustment in order to eliminate incentives for risk selection. Swiss risk adjustment is known to be insufficient, and substantial risk selection incentives remain. This study develops five indicators to monitor residual risk selection. Three indicators target activities of conglomerates of insurers (with the same ownership), which steer enrollees into specific carriers based on applicants' risk profiles. As a proxy for their market power, those indicators estimate the amount of premium-, health care cost-, and risk-adjustment transfer variability that is attributable to conglomerates. Two additional indicators, derived from linear regression, describe the amount of residual cost differences between insurers that are not covered by risk adjustment. All indicators measuring conglomerate-based risk selection activities showed increases between 1996 and 2009, paralleling the establishment of new conglomerates. At their maxima in 2009, the indicator values imply that 56% of the net risk adjustment volume, 34% of premium variability, and 51% cost variability in the market were attributable to conglomerates. From 2010 onwards, all indicators decreased, coinciding with a pre-announced risk adjustment reform implemented in 2012. Likewise, the regression-based indicators suggest that the volume and variance of residual cost differences between insurers that are not equaled out by risk adjustment have decreased markedly since 2009 as a result of the latest reform. Our analysis demonstrates that risk-selection, especially by conglomerates, is a real phenomenon in Switzerland. However, insurers seem to have reduced risk selection activities to optimize their losses and gains from the latest risk adjustment reform.

  18. Residual stresses

    International Nuclear Information System (INIS)

    Sahotra, I.M.

    2006-01-01

    The principal effect of unloading a material strained into the plastic range is to create a permanent set (plastic deformation), which if restricted somehow, gives rise to a system of self-balancing within the same member or reaction balanced by other members of the structure., known as residual stresses. These stresses stay there as locked-in stresses, in the body or a part of it in the absence of any external loading. Residual stresses are induced during hot-rolling and welding differential cooling, cold-forming and extruding: cold straightening and spot heating, fabrication and forced fitting of components constraining the structure to a particular geometry. The areas which cool more quickly develop residual compressive stresses, while the slower cooling areas develop residual tensile stresses, and a self-balancing or reaction balanced system of residual stresses is formed. The phenomenon of residual stresses is the most challenging in its application in surface modification techniques determining endurance mechanism against fracture and fatigue failures. This paper discusses the mechanism of residual stresses, that how the residual stresses are fanned and what their behavior is under the action of external forces. Such as in the case of a circular bar under limit torque, rectangular beam under limt moment, reclaiming of shafts welds and peening etc. (author)

  19. Part 1: Logging residues in piles - Needle loss and fuel quality. Part 2: Nitrogen leaching under piles of logging residues

    International Nuclear Information System (INIS)

    Lehtikangas, P.; Lundkvist, H.

    1991-01-01

    Part 1: Experimental piles were built in three geographical locations during May-Sept. 1989. Logging residues consisted of 95% spruce and 5% pine. Height of the piles varied between 80 and 230 cm. Needles were collected by placing drawers under 40 randomely chosen piles. The drawers were emptied every two weeks during the storage period. Natural needle loss was between 18 and 32% of the total amount of needles after the first two months of storage. At the end of the storage period, 24-42% of the needles had fallen down to the drawers. At the end of the experiment the total needle fall was 95-100% in the shaken piles. According to the results of this study piles smaller than 150 cm had the most effective needle fall. Piles should be placed on open places where the air and sun heat penetrate and dry them. Needles were the most sensitive fraction to variations in precipitation compared to the other components, such as branches. Piles usually dried quickly, but they also rewet easily. This was especially true in the smaller piles. The lowest moisture content was measured at the end of June. The ash content in needles varied between 4 and 8%. 16 refs., 15 figs. Part 2: Three field experiments were equipped with no-tension humus lysimeters. Pairs of lysimeters with the same humus/field layer vegetation material were placed in pairs, one under a pile of felling residues and another in the open clear felling. Leaching of nitrogen as well as pH and electric conductivity in the leachate was followed through sampling of the leachate at regular intervals. The results from the investigation show that: * the amount of leachate was higher in lysimeters in the open clear felling, * pH in the leachate was initially lower under piles of felling residues, * the amount of nitrogen leached was higher in the open clear felling. Thus, storing of felling residues in piles during the summer season did not cause any increase in nitrogen leaching, which had been considered to be a risk

  20. Sustainable System for Residual Hazards Management

    International Nuclear Information System (INIS)

    Kevin M. Kostelnik; James H. Clarke; Jerry L. Harbour

    2004-01-01

    Hazardous, radioactive and other toxic substances have routinely been generated and subsequently disposed of in the shallow subsurface throughout the world. Many of today's waste management techniques do not eliminate the problem, but rather only concentrate or contain the hazardous contaminants. Residual hazards result from the presence of hazardous and/or contaminated material that remains on-site following active operations or the completion of remedial actions. Residual hazards pose continued risk to humans and the environment and represent a significant and chronic problem that require continuous long-term management (i.e. >1000 years). To protect human health and safeguard the natural environment, a sustainable system is required for the proper management of residual hazards. A sustainable system for the management of residual hazards will require the integration of engineered, institutional and land-use controls to isolate residual contaminants and thus minimize the associated hazards. Engineered controls are physical modifications to the natural setting and ecosystem, including the site, facility, and/or the residual materials themselves, in order to reduce or eliminate the potential for exposure to contaminants of concern (COCs). Institutional controls are processes, instruments, and mechanisms designed to influence human behavior and activity. System failure can involve hazardous material escaping from the confinement because of system degradation (i.e., chronic or acute degradation) or by external intrusion of the biosphere into the contaminated material because of the loss of institutional control. An ongoing analysis of contemporary and historic sites suggests that the significance of the loss of institutional controls is a critical pathway because decisions made during the operations/remedial action phase, as well as decisions made throughout the residual hazards management period, are key to the long-term success of the prescribed system. In fact

  1. Highly sensitive rapid fluorescence detection of protein residues on surgical instruments

    International Nuclear Information System (INIS)

    Kovalev, Valeri I; Bartona, James S; Richardson, Patricia R; Jones, Anita C

    2006-01-01

    There is a risk of contamination of surgical instruments by infectious protein residues, in particular, prions which are the agents for Creutzfeldt-Jakob Disease in humans. They are exceptionally resistant to conventional sterilization, therefore it is important to detect their presence as contaminants so that alternative cleaning procedures can be applied. We describe the development of an optimized detection system for fluorescently labelled protein, suitable for in-hospital use. We show that under optimum conditions the technique can detect ∼10 attomole/cm 2 with a scan speed of ∼3-10 cm 2 /s of the test instrument's surface. A theoretical analysis and experimental measurements will be discussed

  2. [Development of residual voltage testing equipment].

    Science.gov (United States)

    Zeng, Xiaohui; Wu, Mingjun; Cao, Li; He, Jinyi; Deng, Zhensheng

    2014-07-01

    For the existing measurement methods of residual voltage which can't turn the power off at peak voltage exactly and simultaneously display waveforms, a new residual voltage detection method is put forward in this paper. First, the zero point of the power supply is detected with zero cross detection circuit and is inputted to a single-chip microcomputer in the form of pulse signal. Secend, when the zero point delays to the peak voltage, the single-chip microcomputer sends control signal to power off the relay. At last, the waveform of the residual voltage is displayed on a principal computer or oscilloscope. The experimental results show that the device designed in this paper can turn the power off at peak voltage and is able to accurately display the voltage waveform immediately after power off and the standard deviation of the residual voltage is less than 0.2 V at exactly one second and later.

  3. Developing a national programme of flood risk management measures: Moldova

    Directory of Open Access Journals (Sweden)

    Ramsbottom David

    2016-01-01

    Full Text Available A Technical Assistance project funded by the European Investment Bank has been undertaken to develop a programme of flood risk management measures for Moldova that will address the main shortcomings in the present flood management system, and provide the basis for long-term improvement. Areas of significant flood risk were identified using national hydraulic and flood risk modelling, and flood hazard and flood risk maps were then prepared for these high risk areas. The flood risk was calculated using 12 indicators representing social, economic and environmental impacts of flooding. Indicator values were combined to provide overall estimates of flood risk. Strategic approaches to flood risk management were identified for each river basin using a multi-criteria analysis. Measures were then identified to achieve the strategic approaches. A programme of measures covering a 20-year period was developed together with a more detailed Short-Term Investment Plan covering the first seven years of the programme. Arrangements are now being made to implement the programme. The technical achievements of the project included national hydrological and hydraulic modelling covering 12,000 km of river, the development of 2-dimensional channel and floodplain hydraulic models from a range of topographic and bathymetric data, and an integrated flood risk assessment that takes account of both economic and non-monetary impacts.

  4. Residual volume on land and when immersed in water: effect on percent body fat.

    Science.gov (United States)

    Demura, Shinichi; Yamaji, Shunsuke; Kitabayashi, Tamotsu

    2006-08-01

    There is a large residual volume (RV) error when assessing percent body fat by means of hydrostatic weighing. It has generally been measured before hydrostatic weighing. However, an individual's maximal exhalations on land and in the water may not be identical. The aims of this study were to compare residual volumes and vital capacities on land and when immersed to the neck in water, and to examine the influence of the measurement error on percent body fat. The participants were 20 healthy Japanese males and 20 healthy Japanese females. To assess the influence of the RV error on percent body fat in both conditions and to evaluate the cross-validity of the prediction equation, another 20 males and 20 females were measured using hydrostatic weighing. Residual volume was measured on land and in the water using a nitrogen wash-out technique based on an open-circuit approach. In water, residual volume was measured with the participant sitting on a chair while the whole body, except the head, was submerged . The trial-to-trial reliabilities of residual volume in both conditions were very good (intraclass correlation coefficient > 0.98). Although residual volume measured under the two conditions did not agree completely, they showed a high correlation (males: 0.880; females: 0.853; P body fat computed using residual volume measured in both conditions was very good for both sexes (males: r = 0.902; females: r = 0.869, P body fat: -3.4 to 2.2% for males; -6.3 to 4.4% for females). We conclude that if these errors are of no importance, residual volume measured on land can be used when assessing body composition.

  5. Influence of organic waste and residue mud additions on chemical, physical and microbial properties of bauxite residue sand.

    Science.gov (United States)

    Jones, Benjamin E H; Haynes, Richard J; Phillips, Ian R

    2011-02-01

    In an alumina refinery, bauxite ore is treated with sodium hydroxide at high temperatures and pressures and for every tone of alumina produced, about 2 tones of alkaline, saline bauxite processing waste is also produced. At Alcoa, a dry stacking system of disposal is used, and it is the sand fraction of the processing waste that is rehabilitated. There is little information available regarding the most appropriate amendments to add to the processing sand to aid in revegetation. The purpose of this study was to investigate how the addition of organic wastes (biosolids and poultry manure), in the presence or absence of added residue mud, would affect the properties of the residue sand and its suitability for revegetation. Samples of freshly deposited residue sand were collected from Alcoa's Kwinana refinery. Samples were treated with phosphogypsum (2% v/v), incubated, and leached. A laboratory experiment was then set up in which the two organic wastes were applied at 0 or the equivalent to 60 tones ha(-1) in combination with residue mud added at rates of 0%, 10% and 20% v/v. Samples were incubated for 8 weeks, after which, key chemical, physical and microbial properties of the residue sand were measured along with seed germination. Additions of residue mud increased exchangeable Na(+), ESP and the pH, and HCO (3) (-) and Na(+) concentrations in saturation paste extracts. Additions of biosolids and poultry manure increased concentrations of extractable P, NH (4) (+) , K, Mg, Cu, Zn, Mn and Fe. Addition of residue mud, in combination with organic wastes, caused a marked decrease in macroporosity and a concomitant increase in mesoporosity, available water holding capacity and the quantity of water held at field capacity. With increasing residue mud additions, the percentage of sample present as sand particles (2 mm diameter) increased; greatest aggregation occurred where a combination of residue mud and poultry manure were added. Stability of aggregates, as measured by

  6. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units

    Directory of Open Access Journals (Sweden)

    Ramage Gordon

    2011-01-01

    Full Text Available Abstract Background The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. Methods The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Results Residual protein was detected on 72% (n = 136 of instruments reprocessed centrally and 90% (n = 170 of instruments reprocessed locally. Significantly less protein (p Conclusions Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.

  7. Residual stresses evaluation in a gas-pipeline crossing

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Maria Cindra [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Almeida, Manoel Messias [COMPAGAS, Curitiba, PR (Brazil); Rebello, Joao Marcos Alcoforado [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Souza Filho, Byron Goncalves de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The X-rays diffraction technique is a well established and effectiveness method in the determination of the residual and applied stresses in fine grained crystalline materials. It allows to characterize and to quantify the magnitude and direction of the existing surface stresses in the studied point of the material. The objective of this work is the evaluation of the surface stresses in a 10 in diameter Natural Gas Distribution Pipeline manufactured from API 5 L Gr B steel of COMPAGAS company, in a crossing with a Natural Gas Transportation Pipeline, in Araucaria-PR. This kind of evaluation is important to establish weather you have to perform a repositioning of one of the pipeline or not. The measurements had been made in two transversal sections of the pipe, the one upstream (170 mm of the external wall of the pipeline) and another one downstream (840 mm of the external wall of the pipeline). Each transversal section measurements where carried out in 3 points: 9 hours, 12 hours and 3 hours. In each measured point of the pipe surface, the longitudinal and transversal stresses had been measured. The magnitude of the surface residual stresses in the pipe varied of +180 MPa at the -210 MPa. The residual stress state on the surface of the points 12 hours region is characterized by tensile stresses and by compressive stresses in the points of 3 and 9 hours region. The surface residual stresses in gas-pipeline have been measured using X-ray diffraction method, by double exposure technique, using a portable apparatus, with Cr-K-alpha radiation. (author)

  8. Functional residual capacity increase during laparoscopic surgery with abdominal wall lift

    Directory of Open Access Journals (Sweden)

    Hiroshi Ueda

    Full Text Available Abstract Background and objectives: The number of laparoscopic surgeries performed is increasing every year and in most cases the pneumoperitoneum method is used. One alternative is the abdominal wall lifting method and this study was undertaken to evaluate changes of functional residual capacity during the abdominal wall lift procedure. Methods: From January to April 2013, 20 patients underwent laparoscopic cholecystectomy at a single institution. All patients were anesthetized using propofol, remifentanil and rocuronium. FRC was measured automatically by Engstrom Carestation before the abdominal wall lift and again 15 minutes after the start of the procedure. Results: After abdominal wall lift, there was a significant increase in functional residual capacity values (before abdominal wall lift 1.48 × 103 mL, after abdominal wall lift 1.64 × 103 mL (p < 0.0001. No complications such as desaturation were observed in any patient during this study. Conclusions: Laparoscopic surgery with abdominal wall lift may be appropriate for patients who have risk factors such as obesity and respiratory disease.

  9. Expanding the disaster risk management framework: Measuring the constructed level of national identity as a factor of political risk

    Directory of Open Access Journals (Sweden)

    Barend Prinsloo

    2016-08-01

    Full Text Available Political risk is identified as a dominant risk category of disaster risk management (DRM which could negatively affect the success of those measures implemented to reduce disaster risk. Key to political risk is the construct of national identity which, if poorly constructed, could greatly contribute to political risk. This article proposed a tool to measure the construct of national identity and to provide recommendations to strengthen the construct in order to mitigate the exacerbating influence it may have on political risk and ultimately on DRM. The design of the measurement tool consisted of a mixed methodological approach employing both quantitative and qualitative data. The data collection instruments included a literature review (which is shortly provided in the previous sections and an empirical study that utilised data obtained through structured questionnaires. Although the results of the proposed measuring instrument did not include a representative sample of all the cultures in SouthAfrica, the results alluded to different levels for the construction of national identity among black and white respondents, possibly because of different ideological expectations among these groups. The results of the study should be considered as a validation of the measuring tool and not necessarily of the construct of national identity in South Africa. The measuring tool is thus promising for future studies to reduce political risk and ultimately disaster risk.

  10. The Role of Cold Work in Eddy Current Residual Stress Measurements in Shot-Peened Nickel-Base Superalloys

    International Nuclear Information System (INIS)

    Yu, F.; Nagy, P. B.

    2006-01-01

    Recently, it was shown that eddy current methods can be adapted to residual stress measurement in shot-peened nickel-base superalloys. However, experimental evidence indicates that the piezoresistivity effect is simply not high enough to account for the observed apparent eddy current conductivity (AECC) increase. At the same time, X-ray diffraction data indicates that 'cold work' lingers even when the residual stress is fully relaxed and the excess AECC is completely gone. It is impossible to account for both observations with a single coherent explanation unless we assume that instead of a single 'cold work' effect, there are two varieties of cold work; type-A and type-B. Type-A cold work (e.g., changes in the microscopic homogeneity of the material) is not detected by X-ray diffraction as it does not significantly affect the beam width, but causes substantial conductivity change and exhibits strong thermal relaxation. Type-B cold work (e.g., dislocations) is detected by X-ray, but causes little or no conductivity change and exhibits weak thermal relaxation. Based on the assumption of two separate cold-work variables and that X-ray diffraction results indicate the presence of type-B, but not type-A, all observed phenomena can be explained. If this working hypothesis is proven right, the separation of residual stress and type-A cold work is less critical because they both relax much earlier and much faster than type-B cold work

  11. Equivalent risky allocation: The new ERA of risk measurement for heterogeneous investors

    NARCIS (Netherlands)

    Plunus, S.; Gillet, R.; Hübner, G.M.B.J.

    2015-01-01

    This paper introduces an investor-specific risk measure derived from the linear-exponential (linex) utility function. It combines the notions of risk perception and risk aversion. To make this measure interpretable and comparable with others like variance or value-at-risk, it is translated into an

  12. Residual stresses

    International Nuclear Information System (INIS)

    Macherauch, E.

    1978-01-01

    Residual stresses are stresses which exist in a material without the influence of external powers and moments. They come into existence when the volume of a material constantly changes its form as a consequence of mechanical, thermal, and/or chemical processes and is hindered by neighbouring volumes. Bodies with residual stress are in mechanical balance. These residual stresses can be manifested by means of all mechanical interventions disturbing this balance. Acoustical, optical, radiological, and magnetical methods involving material changes caused by residual stress can also serve for determining residual stress. Residual stresses have an ambivalent character. In technical practice, they are feared and liked at the same time. They cause trouble because they can be the cause for unexpected behaviour of construction elements. They are feared since they can cause failure, in the worst case with catastrophical consequences. They are appreciated, on the other hand, because, in many cases, they can contribute to improvements of the material behaviour under certain circumstances. But they are especially liked for their giving convenient and (this is most important) mostly uncontrollable explanations. For only in very few cases we have enough knowledge and possibilities for the objective evaluation of residual stresses. (orig.) [de

  13. Restricted Coherent Risk Measures and Actuarial Solvency

    Directory of Open Access Journals (Sweden)

    Christos E. Kountzakis

    2012-01-01

    Full Text Available We prove a general dual representation form for restricted coherent risk measures, and we apply it to a minimization problem of the required solvency capital for an insurance company.

  14. Residual stress analysis in thick uranium films

    International Nuclear Information System (INIS)

    Hodge, A.M.; Foreman, R.J.; Gallegos, G.F.

    2005-01-01

    Residual stress analysis was performed on thick, 1-25 μm, depleted uranium (DU) films deposited on an Al substrate by magnetron sputtering. Two distinct characterization techniques were used to measure substrate curvature before and after deposition. Stress evaluation was performed using the Benabdi/Roche equation, which is based on beam theory of a bi-layer material. The residual stress evolution was studied as a function of coating thickness and applied negative bias voltage (0, -200, -300 V). The stresses developed were always compressive; however, increasing the coating thickness and applying a bias voltage presented a trend towards more tensile stresses and thus an overall reduction of residual stresses

  15. Radionuclides in Bayer process residues: previous analysis for radiological protection

    International Nuclear Information System (INIS)

    Cuccia, Valeria; Rocha, Zildete; Oliveira, Arno H. de

    2011-01-01

    Natural occurring radionuclides are present in many natural resources. Human activities may enhance concentrations of radionuclides and/or enhance potential of exposure to naturally occurring radioactive material (NORM). The industrial residues containing radionuclides have been receiving a considerable global attention, because of the large amounts of NORM containing wastes and the potential long term risks of long-lived radionuclides. Included in this global concern, this work focuses on the characterization of radioactivity in the main residues of Bayer process for alumina production: red mud and sand samples. Usually, the residues of Bayer process are named red mud, in their totality. However, in the industry where the samples were collected, there is an additional residues separation: sand and red mud. The analytical techniques used were gamma spectrometry (HPGe detector) and neutron activation analysis. The concentrations of radionuclides are higher in the red mud than in the sand. These solid residues present activities concentrations enhanced, when compared to bauxite. Further uses for the residues as building material must be more evaluated from the radiological point of view, due to its potential of radiological exposure enhancement, specially caused by radon emission. (author)

  16. Distortion and residual stresses in structures reinforced with titanium straps for improved damage tolerance

    International Nuclear Information System (INIS)

    Liljedahl, C.D.M.; Fitzpatrick, M.E.; Edwards, L.

    2008-01-01

    Distortion and residual stresses induced during the manufacturing process of bonded crack retarders have been investigated. Titanium alloy straps were adhesively bonded to an aluminium alloy SENT specimen to promote fatigue crack growth retardation. The effect of three different strap dimensions was investigated. The spring-back of a component when released from the autoclave and the residual stresses are important factors to take into account when designing a selective reinforcement, as this may alter the local aerodynamic characteristics and reduce the crack bridging effect of the strap. The principal problem with residual stresses is that the tensile nature of the residual stresses in the primary aluminium structure has a negative impact on the crack initiation and crack propagation behaviour in the aluminium. The residual stresses were measured with neutron diffraction and the distortion of the specimens was measured with a contour measurement machine. The bonding process was simulated with a three-dimensional FE model. The residual stresses were found to be tensile close to the strap and slightly compressive on the un-bonded side. Both the distortion and the residual stresses increased with the thickness and the width of the strap. Very good agreement between the measured stresses and the measured distortion and the FE simulation was found

  17. Validation of QuEChERS based method for determination of fenitrothion residues in tomatoes by gas chromatography-flame photometric detector: Decline pattern and risk assessment.

    Science.gov (United States)

    Malhat, Farag; Boulangé, Julien; Abdelraheem, Ehab; Abd Allah, Osama; Abd El-Hamid, Rania; Abd El-Salam, Shokr

    2017-08-15

    A simple and rapid gas chromatography with flame photometric detector (GC-FPD) determination method was developed to detect residue levels and investigate the dissipation pattern and safe use of fenitrothion in tomatoes. A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) using an ethyl acetate-based extraction, followed by a dispersive solid-phase extraction (d-SPE) with primary-secondary amine (PSA) and graphite carbon black (GCB) for clean up, was applied prior to GC-FPD analysis. The method showed satisfactory linearity, recovery and precision. The limits of detection (LOD) and quantification (LOQ) were 0.005 and 0.01mg/kg, respectively. The residue levels of fenitrothion were best described by first order kinetics with a half-life of 2.2days in tomatoes. The potential health risks posed by fenitrothion were not significant, based on supervised residue trial data. The current findings could provide guidance for safe and reasonable use of fenitrothion in tomatoes and prevent health problems to consumers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Volatility and correlation-based systemic risk measures in the US market

    Science.gov (United States)

    Civitarese, Jamil

    2016-10-01

    This paper deals with the problem of how to use simple systemic risk measures to assess portfolio risk characteristics. Using three simple examples taken from previous literature, one based on raw and partial correlations, another based on the eigenvalue decomposition of the covariance matrix and the last one based on an eigenvalue entropy, a Granger-causation analysis revealed some of them are not always a good measure of risk in the S&P 500 and in the VIX. The measures selected do not Granger-cause the VIX index in all windows selected; therefore, in the sense of risk as volatility, the indicators are not always suitable. Nevertheless, their results towards returns are similar to previous works that accept them. A deeper analysis has shown that any symmetric measure based on eigenvalue decomposition of correlation matrices, however, is not useful as a measure of "correlation" risk. The empirical counterpart analysis of this proposition stated that negative correlations are usually small and, therefore, do not heavily distort the behavior of the indicator.

  19. Investigation of residual stress in laser welding dissimilar materials

    International Nuclear Information System (INIS)

    Mirim, Denilson de Camargo; Oliveira, Rene Ramos de; Berretta, Jose Roberto; Rossi, Wagner de; Lima, Nelson Batista de; Delijaicov, Sergio; Gomes, Diego Oliva

    2010-01-01

    One of the most critical problems found in the different materials welding is the residual stress formation, that happens mainly for the fact of those materials they possess coefficients of thermal expansion and different thermal conductivities. Like this in this work the residual tension was evaluated in the technique of welding laser among the steel low carbon, AISI 1010 and AISI 304. The materials were united for it welds autogenous of top with a laser of continuous Nd:YAG in that they were varied the potency, speed and the focus of the laser stayed constant in relation to surface of the sample. The main objective of the study went identification and to analysis of the residual stress in HAZ on both sides of seem. Um planning factorial of two factors at two levels each it was executed for optimization the combination of the factors potency and speed. The obtained answers were the residual stress in different depths in HAZ. In the surface of the sample measures of residual stress were accomplished by the technique of X-ray diffraction. The hole drilling strain gage method it was applied to measure the residual stress on both sides of the union. The results were analyzed using the variance analysis and the statistical regression based on the different influences of the entrance and combination of the factors in the residual stress generated in that union. The results indicate that the development of models can foresee the answers satisfactorily. (author)

  20. The importance of risk-aversion as a measurable psychological parameter governing risk-taking behaviour

    International Nuclear Information System (INIS)

    Thomas, P J

    2013-01-01

    A utility function with risk-aversion as its sole parameter is developed and used to examine the well-known psychological phenomenon, whereby risk averse people adopt behavioural strategies that are extreme and apparently highly risky. The pioneering work of the psychologist, John W. Atkinson, is revisited, and utility theory is used to extend his mathematical model. His explanation of the psychology involved is improved by regarding risk-aversion not as a discrete variable with three possible states: risk averse, risk neutral and risk confident, but as continuous and covering a large range. A probability distribution is derived, the m otivational density , to describe the process of selecting tasks of different degrees of difficulty. An assessment is then made of practicable methods for measuring risk-aversion