WorldWideScience

Sample records for residual doppler broadening

  1. Fatigue damage in superalloys determined using Doppler broadening positron annihilation

    Science.gov (United States)

    Hoeckelman, Donald; Leighly, H. P., Jr.

    1990-01-01

    Axial fatigue specimens of three superalloys, Inconel 718, Incoloy 903 and Haynes 188, were machined from solution-heat-treated material and artificially aged. They were subjected to cyclic loading for a selected number of cycles after which the S parameter was determined using Doppler broadening positron annihilation. Initially, the S parameter decreased, followed by a large increase and a subsequent decline leading to fracture. This has been interpreted as the removal of residual vacancies, the introduction of new defects by cyclic loading, and, finally, a clustering of the defects as microcracks which grow to cause failure.

  2. Calculation of the Doppler broadening function using Fourier analysis

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da Cruz

    2010-01-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function ψ(x,ζ) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for ψ(x,ζ), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  3. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  4. Homogenization of Doppler broadening in spin-noise spectroscopy

    Science.gov (United States)

    Petrov, M. Yu.; Ryzhov, I. I.; Smirnov, D. S.; Belyaev, L. Yu.; Potekhin, R. A.; Glazov, M. M.; Kulyasov, V. N.; Kozlov, G. G.; Aleksandrov, E. B.; Zapasskii, V. S.

    2018-03-01

    The spin-noise spectroscopy, being a nonperturbative linear optics tool, is still reputed to reveal a number of capabilities specific to nonlinear optics techniques. The effect of the Doppler broadening homogenization discovered in this work essentially widens these unique properties of spin-noise spectroscopy. We investigate spin noise of a classical system—cesium atoms vapor with admixture of buffer gas—by measuring the spin-induced Faraday rotation fluctuations in the region of D 2 line. The line, under our experimental conditions, is strongly inhomogeneously broadened due to the Doppler effect. Despite that, optical spectrum of the spin-noise power has the shape typical for the homogeneously broadened line with a dip at the line center. This fact is in stark contrast with the results of previous studies of inhomogeneous quantum dot ensembles and Doppler broadened atomic systems. In addition, the two-color spin-noise measurements have shown, in a highly spectacular way, that fluctuations of the Faraday rotation within the line are either correlated or anticorrelated depending on whether the two wavelengths lie on the same side or on different sides of the resonance. The experimental data are interpreted in the frame of the developed theoretical model which takes into account both kinetics and spin dynamics of Cs atoms. It is shown that the unexpected behavior of the Faraday rotation noise spectra and effective homogenization of the optical transition in the spin-noise measurements are related to smallness of the momentum relaxation time of the atoms as compared with their spin-relaxation time. Our findings demonstrate abilities of spin-noise spectroscopy for studying dynamic properties of inhomogeneously broadened ensembles of randomly moving spins.

  5. Approximation of the Doppler broadening function by Frobenius method

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C.

    2005-01-01

    An analytical approximation of the Doppler broadening function ψ(x,ξ) is proposed. This approximation is based on the solution of the differential equation for ψ(x,ξ) using the methods of Frobenius and the parameters variation. The analytical form derived for ψ(x,ξ) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances mainly for the calculations of multigroup parameters and self-protection factors of the resonances, being the last used to correct microscopic cross-sections measurements by the activation technique. (author)

  6. The derivation of the Doppler broadening function using Frobenius method

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C.

    2006-01-01

    An analytical approximation of the Doppler broadening function ψ(ξ,x) is proposed. This approximation is based on the solution of the differential equation for ψ(ξ,x) using the methods of Frobenius and parameters variation. The analytical form derived for ψ(ξ,x) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances, mainly for calculations of multigroup parameters and resonances self-protection factors, the latter being used to correct microscopic cross section measurements by the activation technique. (author)

  7. Depth resolved Doppler broadening spectroscopy in thin metallic films

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Markus; Pikart, Philip; Hugenschmidt, Christoph [ZWE FRM 2, Garching (Germany); Technische Universitaet Muenchen, Physikdepartment E 21, Garching (Germany)

    2011-07-01

    Within this contribution the examination of thin metallic films by (C)DB ((coincident) Doppler broadening) measurements at different temperatures is presented. Systems with a gold or copper layer with a thickness between 20 and 500 nm were produced by evaporation deposition on silicon substrates. Doppler broadening and positronium fraction were examined in order to investigate annealing processes. In addition, theses samples as well as gold-copper-silicon systems were studied by depth resolved CDB measurements with the goal to obtain information about temperature dependent diffusion processes at the interface. These measurements were performed by use of the highly intensive positron beam NEPOMUC. Depth resolved DB measurements are used for the determination of the positron diffusion length which is highly sensitive to defect concentration. At high temperatures the thermic desorption of positronium can be detected and additionally considered to determine the diffusion length. Depth resolved CDB measurements allow the detection of the chemical surrounding of defects in layered structures. Recently a new heatable sample holder has been set up in order to achieve a sample temperature up to 1000 K.

  8. Electromagnetically induced transparency in thermal Rydberg atoms: superatom model with finite Doppler broadening

    Science.gov (United States)

    Bai, Si-Yin; Bao, Qian-Qian; Tian, Xue-Dong; Liu, Yi-Mou; Wu, Jin-Hui

    2018-04-01

    We study the steady optical responses of a cold atomic ensemble driven into the three-level ladder configuration involving a Rydberg state at finite temperatures. By improving the superatom model with thermal movement included, we calculate relevant atomic coherence effects and find that the residual Doppler broadening at the mK-K temperatures will weaken the nonclassical properties of transmitted probe photons. Furthermore, propagation directions of the probe and coupling fields have a great influence on various properties related to electromagnetically induced transparency. That is, the residual Doppler effect is more destructive to relevant atomic coherence effects in the co-propagation case but can be partially eliminated in the counter-propagation case.

  9. Cavity-ring-down Doppler-broadening primary thermometry

    Science.gov (United States)

    Gotti, Riccardo; Moretti, Luigi; Gatti, Davide; Castrillo, Antonio; Galzerano, Gianluca; Laporta, Paolo; Gianfrani, Livio; Marangoni, Marco

    2018-01-01

    A step forward in Doppler-broadening thermometry is demonstrated using a comb-assisted cavity-ring-down spectroscopic approach applied to an isolated near-infrared line of carbon dioxide at thermodynamic equilibrium. Specifically, the line-shape of the Pe(12 ) line of the (30012 )←(00001 ) band of C O2 at 1.578 µm is accurately measured and its Doppler width extracted from a refined multispectrum fitting procedure accounting for the speed dependence of the relaxation rates, which were found to play a role even at the very low pressures explored, from 1 to 7 Pa. The thermodynamic gas temperature is retrieved with relative uncertainties of 8 ×10-6 (type A) and 11 ×10-6 (type B), which ranks the system at the first place among optical methods. Thanks to a measurement time of only ≈5 h , the technique represents a promising pathway toward the optical determination of the thermodynamic temperature with a global uncertainty at the 10-6 level.

  10. Doppler Broadening Thermometry Based on Cavity Ring-Down Spectroscopy

    Science.gov (United States)

    Hu, Shui-Ming; Cheng, Cunfeng; Wang, Jin; Tan, Yan; Sun, Yu Robert; Liu, An-Wen; Zhang, Jin-Tao

    2014-06-01

    A Doppler broadening thermometry is implemented using a laser-locked cavity ring-down spectrometer [1,2] combined with a temperature-stabilized sample cell. The temperature fluctuation of the gas sample cell is kept below 1 mK for hours. The probing laser is frequency locked at a longitudinal mode of a Fabry-Pérot interferometer made of ultra-low-expansion glass, and the spectral scan is implemented by scanning the sideband produced by an electro-optic modulator. As a result, a kHz precision has been maintained during the measurement of the spectrum of 10 GHz wide. A ro-vibrational line of C_2H_2 is measured at sample pressures of a few Pa. Using a pair of mirrors with a reflectivity of 0.99997 at 787 nm, we are able to detect absorption line profiles with a signal-to-noise ratio of 10^5. Fitting of the recorded spectra allows us to determine the Doppler width with a statistical uncertainty of 10 ppm. Further improvements on the experimental reproducibility and investigations on the collision effects will probably lead to an optical determination of the Boltzmann constant with an uncertainty of a few ppm. H. Pan, C.-F. Cheng, Y. R. Sun, B. Gao, A.-W. Liu, S.-M. Hu, ``Laser-locked, continuously tunable high resolution cavity ring-down spectrometer," Rev. Sci. Instrum. 82, 103110 (2011) Y. R. Sun, H. Pan, C.-F. Cheng, A.-W. Liu, J.-T. Zhang, S.-M. Hu, ``Application of cavity ring-down spectroscopy to the Boltzmann constant determination," Opt. Express, 19, 19993 (2011)

  11. Calculation of the Doppler broadening function using Fourier analysis;Calculo da funcao de alargamento Doppler utilizando analise de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da Cruz

    2010-07-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function {psi}(x,{zeta}) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for {psi}(x,{zeta}), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  12. Application of Energy Window Concept in Doppler Broadening of 238U Cross Section

    International Nuclear Information System (INIS)

    Khassnov, Azamat; Choi, Soo Young; Lee, Deok Jung

    2014-01-01

    Currently, the NJOY code is used for construction and Doppler broadening of microscopic cross sections. There exist several methods or formalisms to produce microscopic cross sections and there are also different methods of Doppler broadening. In this paper, Multi-Level Breit-Wigner (MLBW) formalism and the Psi method are used for generation and Doppler broadening of the resonance cross section. Accuracy of the energy window concept applied MLBW (EW MLBW) Doppler broadened cross section was compared with that of the cross section generated by conventional MLBW (Con MLBW) formalism for 2 38U isotope using MATLAB. The conventional method requires Doppler broadening of all resonances, including resonances far from the target energy point, which do not change much with respect to the temperature change. The energy window concept makes Doppler broadening possible with a smaller number of resonances neighboring to the energy point we are interested in, and just adds up 0 K temperature cross sections of other resonances. Multi-level Breit-Wigner formalism and the Doppler broadening method were used to construct microscopic cross sections of 238 U at different temperatures. The energy window concept was applied only for the 1st resonance energy region (4.5∼11.2 eV). The energy window concept demonstrates high competitiveness because the relative differences were less than 0.0016% for all types of cross sections. The advantage of the energy window concept is that the number of resonances broadened for every energy point is significantly reduced, which allows a reduction of computation time by almost 45 % of Doppler broadening time of the cross section generation at temperatures higher than 0 K

  13. Electromagnetically-induced transparency in Doppler-broadened ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... triple EIT windows depending on the amplitude and detuning of the coupling fields. Keywords. Electromagnetically-induced transparency; atomic ... photon transparency [6] and the effect of spontaneously generated coherence on EIT [7] using homogenously broadened models. Pramana – J. Phys., Vol.

  14. Application of coincidence Doppler broadening spectroscopy to polypropylene and polyethylene: taking into account the positronium formation

    Energy Technology Data Exchange (ETDEWEB)

    Djourelov, N.; Suzuki, T.; Yu, R.S.; Shantarovich, V.; Kondo, K

    2004-07-12

    The coincidence Doppler broadening (CDB) and positron annihilation lifetime (PAL) techniques were applied to study low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene (PP), and antioxidant containing polypropylene (PPA). It was demonstrated that the Doppler-broadened lines for LDPE and PPA could be decomposed into two components a narrow component due to positronium (Ps) annihilation and another broader one due to free positron annihilation. The determined Ps-component in the Doppler-broadened line was used to calculate the Ps-corrected CDB ratios for HDPE and PP to LDPE. Different ways to compare CDB ratios in polymers were discussed. During a long-term ({approx}500 h) positron-irradiation experiment at a low temperature (50 K), a significant enhancement of the carbonyl group concentration in PP was found by means of CDB technique, while the enhancement in HDPE was very slight.

  15. Application of coincidence Doppler broadening spectroscopy to polypropylene and polyethylene: taking into account the positronium formation

    Science.gov (United States)

    Djourelov, N.; Suzuki, T.; Yu, R. S.; Shantarovich, V.; Kondo, K.

    2004-07-01

    The coincidence Doppler broadening (CDB) and positron annihilation lifetime (PAL) techniques were applied to study low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene (PP), and antioxidant containing polypropylene (PPA). It was demonstrated that the Doppler-broadened lines for LDPE and PPA could be decomposed into two components a narrow component due to positronium (Ps) annihilation and another broader one due to free positron annihilation. The determined Ps-component in the Doppler-broadened line was used to calculate the Ps-corrected CDB ratios for HDPE and PP to LDPE. Different ways to compare CDB ratios in polymers were discussed. During a long-term (˜500 h) positron-irradiation experiment at a low temperature (50 K), a significant enhancement of the carbonyl group concentration in PP was found by means of CDB technique, while the enhancement in HDPE was very slight.

  16. A Plasma Edge Electron Density Diagnostic Based on a Doppler-free Measurement of Stark Broadening

    Science.gov (United States)

    Zafar, Abdullah; Martin, Elijah; Shannon, Steve

    2017-10-01

    Passive spectroscopic measurements of Stark broadening have been reliably used to determine electron density for decades. A low-density limit of 1e19 m-3 exists using these passive techniques due to Doppler and instrument broadening. At Oak Ridge National Laboratory, a novel diagnostic approach for measuring electron density using Stark broadening is currently under development and is capable of extending the low-density limit to 1e16 m-3 . The diagnostic is based on measuring the spectral line profile of a Balmer series transition using Doppler-free saturation spectroscopy, a laser-based absorption technique. The spectrum is then fit to a quantum mechanical model using the Explicit Zeeman Stark Spectral Simulator (EZSSS) code to extract the electron density. The increased sensitivity to the electron density is realized because Doppler-free saturation spectroscopy (DFSS) can greatly reduce the Doppler broadening and essentially eliminate the instrument broadening. DFSS has been successfully employed to measure spectral data in a magnetized (500-800 G), low temperature (5 eV), low density (1e17-1e18 m-3), He/H2 and He/CH4 plasma in the mTorr pressure range. Experimentally measured pi and sigma H-alpha spectra, fit using the EZSSS code, will be presented. A quantitative model to accurately predict crossover peaks and dips will also be given. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.

  17. Development and validation of the fast doppler broadening module coupled within RMC code

    International Nuclear Information System (INIS)

    Yu Jiankai; Liang Jin'gang; Yu Ganglin; Wang Kan

    2015-01-01

    It is one of the efficient approach to reduce the memory consumption in Monte Carlo based reactor physical simulations by using the On-the-fly Doppler broadening for temperature dependent nuclear cross sections. RXSP is a nuclear cross sections processing code being developed by REAL team in Department of Engineering Physics in Tsinghua University, which has an excellent performance in Doppler broadening the temperature dependent continuous energy neutron cross sections. To meet the dual requirements of both accuracy and efficiency during the Monte Carlo simulations with many materials and many temperatures in it, this work enables the capability of on-the-fly pre-Doppler broadening cross sections during the neutron transport by coupling the Fast Doppler Broaden module in RXSP code embedded in the RMC code also being developed by REAL team in Tsinghua University. Additionally, the original OpenMP-based parallelism has been successfully converted into the MPI-based framework, being fully compatible with neutron transport in RMC code, which has achieved a vast parallel efficiency improvement. This work also provides a flexible approach to solve Monte Carlo based full core depletion calculation with many temperatures feedback in many isotopes. (author)

  18. An exact formalism for Doppler-broadened neutron cross-sections

    International Nuclear Information System (INIS)

    Catsaros, Nicolas.

    1985-07-01

    An exact formalism (Ψ, Φ) is proposed for the calculation of Breit-Wigner or Adler-Adler Doppler-broadened neutron cross-sections. The well-known (Ψ, Φ) formalism is shown to be a zero-order approximation of the generalized (Ψ, Φ) formalism. (author)

  19. A new formulation for the Doppler broadening function relaxing the approximations of Beth–Plackzec

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Gonçalves, Alessandro C.; Martinez, Aquilino S.; Mesquita, Amir Z.

    2016-01-01

    Highlights: • One of the Beth–Placzek approximation were relaxed. • An additional term in the form of an integral is obtained. • A new mathematical formulation for the Doppler broadening function is proposed. - Abstract: In all nuclear reactors some neutrons can be absorbed in the resonance region and, in the design of these reactors, an accurate treatment of the resonant absorptions is essential. Apart from that, the resonant absorption varies with fuel temperature due to the Doppler broadening of the resonances. The thermal agitation movement in the reactor core is adequately represented in the microscopic cross-section of the neutron-core interaction through the Doppler broadening function. This function is calculated numerically in modern systems for the calculation of macro-group constants, necessary to determine the power distribution of a nuclear reactor. It can also be applied to the calculation of self-shielding factors to correct the measurements of the microscopic cross-sections through the activation technique and used for the approximate calculations of the resonance integrals in heterogeneous fuel cells. In these types of application we can point at the need to develop precise analytical approximations for the Doppler broadening function to be used in the calculation codes that calculate the values of this function. However, the Doppler broadening function is based on a series of approximations proposed by Beth–Plackzec. In this work a relaxation of these approximations is proposed, generating an additional term in the form of an integral. Analytical solutions of this additional term are discussed. The results obtained show that the new term is important for high temperatures.

  20. Solitary waves of surface plasmon polariton via phase shifts under Doppler broadening and Kerr nonlinearity

    Science.gov (United States)

    Ahmad, S.; Ahmad, A.; Bacha, B. A.; Khan, A. A.; Abdul Jabar, M. S.

    2017-12-01

    Surface Plasmon Polaritons (SPPs) are theoretically investigated at the interface of a dielectric metal and gold. The output pulse from the dielectric is used as the input pulse for the generation of SPPs. The SPPs show soliton-like behavior at the interface. The solitary form of a SPP is maintained under the effects of Kerr nonlinearity, Doppler broadening and Fresnel dragging whereas its phase shift is significantly modified. A 0.3radian phase shift is calculated in the presence of both Kerr nonlinearity and Fresnel dragging in the absence of plasma motion. The phase shift is enhanced to 60radian due to the combined effect of Doppler broadening, Kerr nonlinearity and Fresnel dragging. The results may have significant applications in nano-photonics, optical tweezers, photovoltaic devices, plasmonster and sensing technology.

  1. Doppler and time-travel broadening in ICR plasma isotope separation

    International Nuclear Information System (INIS)

    Karchevskii, A.I.; Potanin, E.P.

    1994-01-01

    Isotopically-selective ion-cyclotron resonance (ICR) heating is one of the most promising plasma isotope separation methods. The separation degree of ICR separation in a plasma depends on the resonance heating selectivity. The selectivity is due to the isotopically-adjacent accelerated ions resonance curve overlapping and therefore, is determined by the width of the resonance curves. In the case of a collisionless plasma in an ideal homogeneous longitudinal magnetic field, the line broadening is mainly determined by Doppler and time-travel effects. These effects differ in nature, and one has some difficulties in distinguishing them when interpreting the resonance curves because both broadenings depend on ion axial velocities. We consider the simplest case: the extrenal heating alternating electric field does not depend on the axial coordinate (the wave number γ = 0). Hence, in this case the Doppler effect does not occur

  2. A new expression for doppler broadening function based on Fourier Cosine Transform

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da C.; Martinez, Aquilino S.; Silva, Fernando C. da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mails: agoncalves@con.ufrj.br; aquilino@lmp.ufrj.br; fernando@con.ufrj.br

    2007-07-01

    The main objective of this paper consists of the derivation of an analytical solution for the Doppler broadening function {psi} ({xi}, x). The analytical solution is derived from a new integral expression for the {psi} ({xi}, x) function, which can be interpreted as a Fourier cosine transform. The expression obtained for {psi} ({xi}, x) in terms of elementary functions, proved quite simple and accurate, leading to a similar solution obtained through the differential equation for the {psi} ({xi}, x) function, using the methods of Frobenius and of parameter variation. The Doppler broadening function is widely used in applications related to the treatment of nuclear resonances, calculations of multigroup parameters and resonance self-shielding factors, and to correct microscopic cross section measurements through the activation technique. (author)

  3. A new expression for doppler broadening function based on Fourier Cosine Transform

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da C.; Martinez, Aquilino S.; Silva, Fernando C. da

    2007-01-01

    The main objective of this paper consists of the derivation of an analytical solution for the Doppler broadening function Ψ (ξ, x). The analytical solution is derived from a new integral expression for the Ψ (ξ, x) function, which can be interpreted as a Fourier cosine transform. The expression obtained for Ψ (ξ, x) in terms of elementary functions, proved quite simple and accurate, leading to a similar solution obtained through the differential equation for the Ψ (ξ, x) function, using the methods of Frobenius and of parameter variation. The Doppler broadening function is widely used in applications related to the treatment of nuclear resonances, calculations of multigroup parameters and resonance self-shielding factors, and to correct microscopic cross section measurements through the activation technique. (author)

  4. Solution of the Doppler broadening function based on the fourier cosine transform

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da C [COPPE/UFRJ - Programa de Engenharia Nuclear, Universidade Federal do Rio de Janeiro, P.O. Box 68509, 21941-914 Rio de Janeiro, RJ (Brazil)], E-mail: agoncalves@con.ufrj.br; Martinez, Aquilino S.; Silva, Fernando C. da [COPPE/UFRJ - Programa de Engenharia Nuclear, Universidade Federal do Rio de Janeiro, P.O. Box 68509, 21941-914 Rio de Janeiro, RJ (Brazil)

    2008-10-15

    This paper provides a new integral representation for the Doppler broadening function {psi}({xi}, x), which is interpreted as being a Fourier cosine transform. This integral form allows the obtaining of an analytical solution in a simple and accurate functional manner as regards the elementary functions. The solution obtained through the new integral representation can be widely used in several applications such as the calculation of self-shielding factors and measurement corrections for the microscopic cross section through the activation technique.

  5. Solution of the Doppler broadening function based on the fourier cosine transform

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da C; Martinez, Aquilino S.; Silva, Fernando C. da

    2008-01-01

    This paper provides a new integral representation for the Doppler broadening function ψ(ξ, x), which is interpreted as being a Fourier cosine transform. This integral form allows the obtaining of an analytical solution in a simple and accurate functional manner as regards the elementary functions. The solution obtained through the new integral representation can be widely used in several applications such as the calculation of self-shielding factors and measurement corrections for the microscopic cross section through the activation technique

  6. Positron Annihilation in Carbon Nanotubes Studied by Coincidence Doppler Broadening Spectroscopy

    Science.gov (United States)

    Murakami, H.; Sato, K.; Kanazawa, I.; Sano, M.

    2008-05-01

    In order to assign the sites of positron annihilation, coincidence Doppler broadening spectra were measured for a highly oriented pyrolytic graphite crystal, graphite powder, multi-walled carbon nanotubes (MNTs) and cup-stacked carbon nanotubes (CNTs). The spectrum for graphite powder normalized to that for highly oriented pyrolytic graphite (HOPG) is almost flat in the momentum region from 7×10-3 to 13×10-3 mec, having a ratio close to unity. The flat spectrum demonstrates that positrons injected into graphite powder annihilate in the interlayer spaces of piled graphite sheets, in the same manner as positrons in highly oriented pyrolytic graphite annihilate in the bulk. The coincidence Doppler broadening spectra for MNTs and CNTs are quite different from that for highly oriented pyrolytic graphite, which indicates that positrons injected into MNTs and CYTs annihilate not in the bulk, but on surface. The positron lifetime spectrum for multi-walled carbon nanotubes is analyzed in terms of a single component due to surface-trapped positrons, while that for CNTs is decomposed into three components attributable to para-positronium surface-trapped positrons and ortho-positronium. The difference between the coincidence Doppler broadening spectrum for CNTs and that for MNTs is explained in terms of positron annihilation on zigzag surfaces of CNTs which are composed of both graphite-sheet and graphite-edge planes.

  7. Linear and nonlinear light propagations in a Doppler-broadened medium via electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Li Liang; Huang Guoxiang

    2010-01-01

    We present a systematic theoretical study to deal with linear and nonlinear light propagations in a Doppler-broadened three-level Λ system via electromagnetically induced transparency (EIT), with incoherent population exchange between two lower energy levels taken into account. Through a careful analysis of base state and linear excitation, we show that the EIT condition of the system is given by |Ω c | 2 γ 31 >>2γ 21 Δω D 2 , where Ω c is half the Rabi frequency of the control field, Δω D is the Doppler width, and γ jl is the decay rate of the coherence between states |j> and |l>. Under this condition, the effect of incoherent population exchange is insignificant, while dephasing dominates the decoherence of the system. This condition also ensures the validity of the weak nonlinear perturbation theory used in this work for solving the Maxwell-Bloch equations with inhomogeneous broadening. We then investigate the nonlinear propagation of the probe field and show that it is possible to form temporal optical solitons in the Doppler-broadened medium. Such solitons have ultraslow propagating velocity and can be generated in very low light power. The possibility of realizing (1+1)-dimensional and (2+1)-dimensional spatial optical solitons in the adiabatic regime of the system is also discussed.

  8. Approximation of the Doppler broadening function by Frobenius method; Aproximacao da funcao de alargamento doppler atraves do metodo de Frobenius

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A.P. [Centro Federal de Educacao Tecnologica de Quimica de Nilopolis/RJ (CEFET), RJ (Brazil)]. E-mail: dpalma@cefeteq.br; Martinez, Aquilino S.; Silva, Fernando C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br; fernando@lmn.con.ufrj.br

    2005-07-01

    An analytical approximation of the Doppler broadening function {psi}(x,{xi}) is proposed. This approximation is based on the solution of the differential equation for {psi}(x,{xi}) using the methods of Frobenius and the parameters variation. The analytical form derived for {psi}(x,{xi}) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances mainly for the calculations of multigroup parameters and self-protection factors of the resonances, being the last used to correct microscopic cross-sections measurements by the activation technique. (author)

  9. PROBLEM DEPENDENT DOPPLER BROADENING OF CONTINUOUS ENERGY CROSS SECTIONS IN THE KENO MONTE CARLO COMPUTER CODE

    Energy Technology Data Exchange (ETDEWEB)

    Hart, S. W. D. [University of Tennessee, Knoxville (UTK); Maldonado, G. Ivan [University of Tennessee, Knoxville (UTK); Celik, Cihangir [ORNL; Leal, Luiz C [ORNL

    2014-01-01

    For many Monte Carlo codes cross sections are generally only created at a set of predetermined temperatures. This causes an increase in error as one moves further and further away from these temperatures in the Monte Carlo model. This paper discusses recent progress in the Scale Monte Carlo module KENO to create problem dependent, Doppler broadened, cross sections. Currently only broadening the 1D cross sections and probability tables is addressed. The approach uses a finite difference method to calculate the temperature dependent cross-sections for the 1D data, and a simple linear-logarithmic interpolation in the square root of temperature for the probability tables. Work is also ongoing to address broadening theS (alpha , beta) tables. With the current approach the temperature dependent cross sections are Doppler broadened before transport starts, and, for all but a few isotopes, the impact on cross section loading is negligible. Results can be compared with those obtained by using multigroup libraries, as KENO currently does interpolation on the multigroup cross sections to determine temperature dependent cross-sections. Current results compare favorably with these expected results.

  10. Electron irradiation effect of polyurethane using coincidence doppler-broadening spectroscopy

    International Nuclear Information System (INIS)

    Yang, D.J.; Zhang, J.D.; Leung, J.K.C.; Beling, C.D.; Liu, L.B.

    2006-01-01

    Full text: To understand the electron irradiation effects on polymer, polyether-urethane (ETPU) samples of 2m m in thickness and 1 0 m m in diameter were irradiated by a 1.8M eV electron beam with beam current of 3 ma at room temperature. The irradiated doses are 5 kGy, 10 kGy, 15 kGy, 30 kGy, 100 kGy and 150 kGy. ETPU was manufactured by mixing PTMG-100, TDI-100 and MOCA. The momentum density distributions (MMDs) of electrons taking part in the annihilation processes of positron-electron pairs in ETPU have been measured by coincidence Doppler-broadening spectroscopy (CDBS). By presenting the ratio of the counts in every channel of the measured CDB spectrum to the corresponding counts from a reference spectrum (pristine ETPU), we observed that the change in MMDs is not significant for doses lower than 10 kGy. However, high momentum part of MMDs exhibit an obvious decrease for dose exceeding 15 kGy and then slowly down to steady with doses until 150 kGy. This valley occurs at around 15 x1 0 3m οc and is well known as oxygen-specific, indicative of a less positron trapping by oxygen atoms in some samples of higher dose radiation. It is postulated that the radiation will break the crosslinkings, allowing the trace water and oxygen molecules to be released from the sample surface. Excess NCO groups in ETPU would crosslink with urethane and urea groups to produce allophanate and biuret groups. After receiving a certain amount of electron irradiation, crosslinked allophanate and biuret groups would produce degradation. Thus, residual water and oxygen trapped in ETPU by the crosslinking would diffuse out. However, the irradiation doses up to 150 kGy in this experiment are still not large enough to induce strong degradation of urethane and urea groups

  11. Compact extended model for doppler broadening of neutron absorption resonances in solids

    International Nuclear Information System (INIS)

    Villanueva, A. J; Granada, J.R

    2009-01-01

    We present a simplified compact model for calculating Doppler broadening of neutron absorption resonances in an incoherent Debye solid. Our model extends the effective temperature gas model to cover the whole range of energies and temperatures, and reduces the information of the dynamical system to a minimum content compatible with a much better accuracy of the calculation. This model is thus capable of replacing the existing algorithm in standard codes for resonance cross sections preparation aimed at neutron and reactor physics calculations. The model is applied to the 238 U 6.671 eV effective broadened cross section. We also show how this model can be used for thermometry in an improved fashion compared to the effective temperature gas model. Experimental data of the same resonance at low and high temperatures are also shown and the performances of each model are put to the test on this basis. [es

  12. Positron annihilation in polypropylene studied by lifetime and coincidence Doppler-broadening spectroscopy

    Science.gov (United States)

    Djourelov, N.; He, C.; Suzuki, T.; Shantarovich, V. P.; Ito, Y.; Kondo, K.; Ito, Y.

    2003-12-01

    The momentum density distributions (MDDs) of electrons taking part in the annihilation processes in polypropylene (PP) have been measured by coincidence Doppler-broadening spectroscopy. MDDs at the beginning of measurements to those at the saturation level of Ps formation have been compared in order to follow the possible changes in concentration of carbonyl groups (CG). A high initial CG concentration in PP has been observed, while for antioxidant-containing PP no significant presence of CG has been detected, and no changes have been observed during positron irradiation.

  13. Investigation of cation vacancies in Zinc substituted maghemite by positron annihilation lifetime and Doppler broadening spectroscopy.

    Science.gov (United States)

    Asgarian, S M; Kargar, Z; Mozaffari, M

    2017-07-01

    In this work we investigated vacancies in maghemite and Zn substituted maghemite (γ-Fe 2-y Zn 3y/2 O 3 , y=0.0, 0.11, 0.24, 0.36, 0.50 and 0.66) nanoparticles using coincidence Doppler broadening and positron annihilation lifetime spectroscopy. Coincidence Doppler broadening spectroscopy (CDBS) measurements showed that the positrons annihilated in cation vacancies that surrounded by oxygen anions. Also, the CDBS showed that in pure maghemite and in the y=0.11 samples the vacancies are in octahedral and tetrahedral sites, respectively. For other samples they are distributed in both octahedral and tetrahedral sites. The positron annihilation lifetime spectroscopy (PALS) measurements confirmed the results of the CDBS measurements and also exhibited that the number of vacancies in y=0.36 sample is less than the other samples. This is attributed to Zn substituted magnetite phase in this sample as well as Zn substituted maghemite phase. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Positron annihilation in polypropylene studied by lifetime and coincidence Doppler-broadening spectroscopy[Positron annihilation; Doppler broadening; Coincidence Doppler system; PP; Antioxidant; Carbonyl group; Irradiation effect; Core electrons

    Energy Technology Data Exchange (ETDEWEB)

    Djourelov, N. E-mail: nikdjour@post.kek.jp; He, C.; Suzuki, T.; Shantarovich, V.P.; Ito, Y.; Kondo, K.; Ito, Y

    2003-12-01

    The momentum density distributions (MDDs) of electrons taking part in the annihilation processes in polypropylene (PP) have been measured by coincidence Doppler-broadening spectroscopy. MDDs at the beginning of measurements to those at the saturation level of Ps formation have been compared in order to follow the possible changes in concentration of carbonyl groups (CG). A high initial CG concentration in PP has been observed, while for antioxidant-containing PP no significant presence of CG has been detected, and no changes have been observed during positron irradiation.

  15. Point defects in MnSi and YBCO studied by Doppler Broadening Spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Markus

    2015-10-28

    The positron beam NEPOMUC was used in order to investigate MnSi and YBa{sub 2}Cu{sub 3}O{sub 7-δ} (YBCO) single crystals. The Doppler broadening of the annihilation radiation of electron-positron pairs was analyzed. Thus, the concentration of Mn vacancies in MnSi crystals was determined. In thin YBCO films, the Doppler broadening is correlated with the oxygen deficiency δ. Its spatial distribution and its high-temperature behavior were studied using positrons.

  16. New approximations for the Doppler broadening function applied to the calculation of resonance self-shielding factors

    International Nuclear Information System (INIS)

    Palma, Daniel A.; Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C.

    2008-01-01

    The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function ψ(x,ξ) to determine the resonance self-shielding factors in the epithermal range G epi (τ,ξ). Two new analytical approximations for the Doppler broadening function ψ(x,ξ) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the ψ(x,ξ) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G epi (τ,ξ). The results obtained provided satisfactory accuracy. (authors)

  17. Software for analysis of waveforms acquired by digital Doppler broadening spectrometer

    International Nuclear Information System (INIS)

    Vlcek, M; Čížek, J; Procházka, I

    2013-01-01

    High-resolution digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation was recently developed and tested. In this spectrometer pulses from high purity Ge (HPGe) detectors are sampled in the real time by fast digitizers and subsequently analyzed off-line by software. We present description of the software routines used for pulse shape analysis in two spectrometer configurations: (i) semi-digital setup in which detector pulses shaped in spectroscopic amplifiers (SA's) are digitized; (ii) pure digital setup in which pulses from detector pre-amplifiers are digitized directly. Software developed in this work will be freely available in the form of source code and pre-compiled binaries.

  18. Diagnostic Technique of Neutron Doppler Broadening for Indirectly-Driven Implosions

    Science.gov (United States)

    Xiong, Yong; Ding, Yongkun; Zheng, Zhijian; Chen, Ming

    2004-06-01

    The neutron Doppler broadening in inertial confinement fusion has been acquired from the time of flight for the neutron, from which the fuel ion temperature can be derived. An ultrafast-quenched plastic scintillation detector was used to measure the time of flight for the neutron at a low-imploded DT neutron yield (5×107-1×108) in the experiment performed on the Shenguang II laser facility. The typical temperatures of ablating targets for indirect drive were around 2.8 keV and the uncertainties were ±30%-±40%. The detection efficiency of the detector for DT neutrons was calibrated at a K-400 accelerator. The time response function of the detection system was calibrated by imploded neutrons from a DT-filled capsule, which can be regarded as a δ function pulsed neutron source due to its much narrower pulse width than that of the measured neutron time-of-flight spectrum.

  19. Diagnostic technique of neutron doppler broadening for indirectly-driven implosions

    International Nuclear Information System (INIS)

    Xiong Yong; Ding Yongkun; Zheng Zhijian; Chen Ming

    2004-01-01

    The neutron Doppler broadening in inertial confinement fusion has been acquired from the time of flight for the neutron, from which the fuel ion temperature can be derived. An ultrafast-quenched plastic scintillation detector was used to measure the time of flight for the neutron at a low-imploded DT neutron yield (5 x 10 7 - 1 x 10 8 ) in the experiment performed on the Shenguang II laser facility. The typical temperatures of ablating targets for indirect drive were around 2.8 keV and the uncertainties were ±30%-±40%. The detection efficiency of the detector for DT neutrons was calibrated at a K-400 accelerator. The time response function of the detection system was calibrated by imploded neutrons from a DT-filled capsule, which can be regarded as a δ function pulsed neutron source due to its much narrower pulse width than that of the measured neutron time-of-flight spectrum. (authors)

  20. Pre-precipitation studies in an Al-Zn alloy by positron Doppler broadening measurements

    International Nuclear Information System (INIS)

    Panchanadeeswaran, S.; Plichta, M.R.; Byrne, J.G.

    1984-01-01

    Positron annihilation studies using measurements of Doppler broadening of annihilation γ-rays have been carried out in an Al-8.5 wt% Zn alloy. More than 90% of positron trapping is believed to occur at GP zones formed on quenching the supersaturated solid solution. The dissolution of GP zones above 373 K was revealed by drastic narrowing of the Doppler energy spectrum for samples aged above 373 K. The kinetics of formation of GP zones at ambient temperatures is drastically reduced when the alloy containing GP zones formed during quenching from supersaturated solid solution was reverted at 403 K and reaged at ambient temperature. It was also observed that, even after long reageing, the total number of GP zones formed is much lower than in a directly quenched alloy. The kinetics of formation of GP zones are also reduced by quenching from a single phase to an intermediate temperature where GP zones are not stable, followed by ageing at ambient temperature. Transmission electron micrographs revealed the presence of dislocation loops in alloys quenched from temperature above 773 K. The sensitivity of positrons to the presence of dislocation loops was analysed using the R parameter analysis. (author)

  1. Phonon characteristics of high Tc superconductors from neutron Doppler broadening measurements

    International Nuclear Information System (INIS)

    Trela, W.J.; Kwei, G.H.; Lynn, J.E.; Meggers, K.

    1994-01-01

    Statistical information on the phonon frequency spectrum of materials can be measured by neutron transmission techniques if they contain nuclei with low energy resonances, narrow enough to be Doppler-broadened, in their neutron cross sections. The authors have carried out some measurements using this technique for materials of the lanthanum barium cuprate class, La 2-x Ba x CuO 4 . Two samples with slightly different concentrations of oxygen, one being superconductive, the other not, were examined. Pure lanthanum cuprate was also measured. Lanthanum, barium and copper all have relatively low energy narrow resonances. Thus it should be possible to detect differences in the phonons carried by different kinds of atom in the lattice. Neutron cross section measurements have been made with high energy resolution and statistical precision on the 59m flight path of LANSCE, the pulsed spallation neutron source at Los Alamos National Laboratory. Measurements on all three materials were made over a range of temperatures from 15K to 300K, with small steps through the critical temperature region near 27K. No significant changes in the mean phonon energy of the lanthanum atoms were observed near the critical temperature of the super-conducting material. It appears however that the mean phonon energy of lanthanum in the superconductor is considerably higher than that in the non-superconductors. The samples used in this series of experiments were too thin in barium and copper to determine anything significant about their phonon spectra

  2. Fe2+ ion irradiated JRQ steel investigated by nanoindentation and slow-positron Doppler broadening spectroscopy

    Science.gov (United States)

    Pecko, Stanislav; Heintze, Cornelia; Bergner, Frank; Anwand, Wolfgang; Slugeň, Vladimír

    2018-01-01

    A model reactor pressure vessel (RPV) steel, known as JRQ, was manufactured in Japan for IAEA neutron embrittlement research studies in late 80 s. This model alloy belongs to the commercially used steel of A533B-1 type and shows relatively large changes in mechanical properties after a neutron irradiation due to considerable copper content (0.15 wt%). In order to simulate neutron irradiation and investigate the hardening effect, studied specimens of JRQ steel were exposed to Fe2+ ion irradiation in five different exposures calculated using the SRIM code. The ion energy of 5 MeV, temperature at 300 °C and the flux of 1.0 × 1011 cm-2 s-1 were the same during the irradiations. The hardening was investigated and observed by means of nanoindentation technique and a defect profile of irradiated steels was measured by Slow-positron Doppler broadening spectroscopy (DBS). The observed increasing trend of nanohardness as a function of fluence is in good agreement with the trend observed on the basis of Vickers hardness measured for neutron-irradiated JRQ. This confirms that Cu precipitation is most likely responsible for the observed irradiation hardening and that neutron-irradiation-induced damage can be simulated using ion irradiation in the present case. We have also excluded open volume (vacancy type) defects in the crystal lattice of JRQ steel from a responsibility for the damage arising by the Fe2+ ion irradiation.

  3. Intensity dependence narrowing of electromagnetically induced absorption in a Doppler-broadened medium

    International Nuclear Information System (INIS)

    Dimitrijevic, J.; Arsenovic, D.; Jelenkovic, B. M.

    2007-01-01

    In this paper, we present a theoretical model for studying the interaction between linearly polarized laser light and near-degenerated Zeeman sublevels for a multiple V-type atomic system of 2 S 1/2 F g =2→ 2 P 3/2 F e =3 transition in 87 Rb. We have calculated the laser absorption in a Hanle configuration, as well as the amplitudes and the widths of electromagnetically induced absorption (EIA) in the range of laser intensities from 0.01 to 40 mW/cm 2 . Our results, showing nonvanishing EIA amplitude, a nonmonotonic increase of the EIA width for the increase of laser intensity, and pronounced shape differences of the Hanle EIA curves at different laser intensities, are in good agreement with recent experimental results. We have found that the EIA behaves differently than the electromagnetically induced transparency (EIT) as a function of the laser intensity. Both the amplitude and width of the EIA have narrow maximums at 1 to 2 mW/cm 2 . We have shown the strong influence of Doppler broadening of atomic transition on Hanle resonances and have suggested the explanation of it

  4. Phonon characteristics of high {Tc} superconductors from neutron Doppler broadening measurements

    Energy Technology Data Exchange (ETDEWEB)

    Trela, W.J.; Kwei, G.H.; Lynn, J.E. [Los Alamos National Lab., NM (United States); Meggers, K. [Univ. of Kiel (Germany)

    1994-12-01

    Statistical information on the phonon frequency spectrum of materials can be measured by neutron transmission techniques if they contain nuclei with low energy resonances, narrow enough to be Doppler-broadened, in their neutron cross sections. The authors have carried out some measurements using this technique for materials of the lanthanum barium cuprate class, La{sub 2{minus}x}Ba{sub x}CuO{sub 4}. Two samples with slightly different concentrations of oxygen, one being superconductive, the other not, were examined. Pure lanthanum cuprate was also measured. Lanthanum, barium and copper all have relatively low energy narrow resonances. Thus it should be possible to detect differences in the phonons carried by different kinds of atom in the lattice. Neutron cross section measurements have been made with high energy resolution and statistical precision on the 59m flight path of LANSCE, the pulsed spallation neutron source at Los Alamos National Laboratory. Measurements on all three materials were made over a range of temperatures from 15K to 300K, with small steps through the critical temperature region near 27K. No significant changes in the mean phonon energy of the lanthanum atoms were observed near the critical temperature of the super-conducting material. It appears however that the mean phonon energy of lanthanum in the superconductor is considerably higher than that in the non-superconductors. The samples used in this series of experiments were too thin in barium and copper to determine anything significant about their phonon spectra.

  5. Detection of helium in irradiated Fe9Cr alloys by coincidence Doppler broadening of slow positron annihilation

    Science.gov (United States)

    Cao, Xingzhong; Zhu, Te; Jin, Shuoxue; Kuang, Peng; Zhang, Peng; Lu, Eryang; Gong, Yihao; Guo, Liping; Wang, Baoyi

    2017-03-01

    An element analysis method, coincidence Doppler broadening spectroscopy of slow positron annihilation, was employed to detect helium in ion-irradiated Fe9Cr alloys. Spectra with higher peak to background ratio were recorded using a two-HPGe detector coincidence measuring system. It means that information in the high-momentum area of the spectra can be used to identify helium in metals. This identification is not entirely dependent on the helium concentration in the specimens, but is related to the structure and microscopic arrangement of atoms surrounding the positron annihilation site. The results of Doppler broadening spectroscopy and transmission electron microscopy show that vacancies and dislocations were formed in ion-irradiated specimens. Thermal helium desorption spectrometry was performed to obtain the types of He traps.

  6. New approximations for the Doppler broadening function applied to the calculation of resonance self-shielding factors

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A. [CEFET QUIMICA de Nilopolis/RJ, Rio de Janeiro (Brazil); Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C. [COPPE/UFRJ - Programa de Engenharia Nuclear, Rio de Janeiro (Brazil)

    2008-07-01

    The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function psi(x,xi) to determine the resonance self-shielding factors in the epithermal range G{sub epi} (tau,xi). Two new analytical approximations for the Doppler broadening function psi(x,xi) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the psi(x,xi) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G{sub epi} (tau,xi). The results obtained provided satisfactory accuracy. (authors)

  7. Characterization of ion-irradiated ODS Fe–Cr alloys by doppler broadening spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Parente, P.; Leguey, T. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Castro, V. de, E-mail: vanessa.decastro@uc3m.es [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Gigl, T.; Reiner, M.; Hugenschmidt, C. [FRM II and Physics Department, Technische Universität München, 85747 Garching (Germany); Pareja, R. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain)

    2015-09-15

    The damage profile of oxide dispersion strengthened steels after single-, or simultaneous triple-ion irradiation at different conditions has been characterized using a low energy positron beam in order to provide information on microstructural changes induced by irradiation. Doppler broadening and coincident Doppler broadening measurements of the positron annihilation line have been performed on different Fe–Cr–(W,Ti) alloys reinforced with Y{sub 2}O{sub 3}, to identify the nature and stability of irradiation-induced open-volume defects and their possible association with the oxide nanoparticles. It was found that irradiation induced vacancy clusters are associated with Cr atoms. The results are of highest interest for modeling the damage induced by 14 MeV neutrons in reduced activation Fe–Cr alloys relevant for fusion devices.

  8. The deconvolution of Doppler-broadened positron annihilation measurements using fast Fourier transforms and power spectral analysis

    International Nuclear Information System (INIS)

    Schaffer, J.P.; Shaughnessy, E.J.; Jones, P.L.

    1984-01-01

    A deconvolution procedure which corrects Doppler-broadened positron annihilation spectra for instrument resolution is described. The method employs fast Fourier transforms, is model independent, and does not require iteration. The mathematical difficulties associated with the incorrectly posed first order Fredholm integral equation are overcome by using power spectral analysis to select a limited number of low frequency Fourier coefficients. The FFT/power spectrum method is then demonstrated for an irradiated high purity single crystal sapphire sample. (orig.)

  9. Compton energy-absorption scattering cross-sections for H, C, N, O, P, Ca and assessment of doppler broadening

    CERN Document Server

    Rao, D V; Brunetti, A; Gigante, G E

    2003-01-01

    Total Compton, individual shell and Compton energy-absorption scattering cross-sections are evaluated in the energy region 0.005 to 10 MeV for H, C. N, O. P and Ca. Compton energy absorption cross-sections deviate numerically with available values. The cause of the numerical discrepancies are not fully understood but can be attributed to Doppler broadening of the Compton scattered photons through a given angle. (authors)

  10. Kernel reconstruction methods for Doppler broadening - Temperature interpolation by linear combination of reference cross sections at optimally chosen temperatures

    Science.gov (United States)

    Ducru, Pablo; Josey, Colin; Dibert, Karia; Sobes, Vladimir; Forget, Benoit; Smith, Kord

    2017-04-01

    This article establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (Tj). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T0 to a higher temperature T - namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernel of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (Tj). The choice of the L2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (Tj) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [Tmin ,Tmax ]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope 238U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of 238U total cross section over the temperature range [ 300 K , 3000 K ] with only 9 reference temperatures.

  11. The influence of radiation and light on Ps formation in PMMA and PE studied by coincidence Doppler-broadening spectroscopy

    CERN Document Server

    Suzuki, T; Shantarovich, V; Kondo, K; Hamada, E; Matso, M; Ma Li; Ito, Y

    2003-01-01

    Using two Ge detectors, the high-resolution Doppler-broadening energy spectra of positron annihilation gamma rays has been obtained by measuring the coincidences of the two photons. Light bleaching and oxygen effects on positron annihilation were investigated in this way. A large enhancement of the high-momentum part of the coincidence Doppler spectra was observed in poly(methylmethacrylate) (PMMA), which contains oxygen atoms in the polymer structure. Bleaching experiments in PMMA and in copolymer ethylene-methylmethacrylate EMMA (LDPE+MMA 3 mol%) have demonstrated that the enhancement effect may be due to the trapping of positrons by the polar -C sup + 6-O sup - groups, followed by positron annihilation with the electrons belonging to oxygen.

  12. Continuous amorphization of Cu-Zr studied by positron lifetime and two-dimensional Doppler broadening measurements

    International Nuclear Information System (INIS)

    Puff, W.; Rabitsch, H.; Wuerschum, R.; Wilde, G.

    2007-01-01

    Positron lifetime and 2-dimensional Doppler broadening measurements were used to study the amorphization of Cu 60 Zr 40 induced by consecutive folding and rolling. In an intermediate state of folding and rolling cycles a complex microstructure evolves with structural free volumes exhibiting a local environment with enhanced Zr content. In the fully amorphous state after 80 cycles, free volumes of the size of a few missing atoms occur which is contrast to amorphous alloys prepared by melt-spinning. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Low-temperature positron lifetime and Doppler-broadening measurements for single-crystal nickel oxide containing cation vacancies

    International Nuclear Information System (INIS)

    Waber, J.T.; Snead, C.L. Jr.; Lynn, K.G.

    1985-01-01

    Lifetime and Doppler-broadening measurements for positron annihilation in substoichiometric nickelous oxide have been made concomitantly from liquid-helium to room temperature. The concentration of cation vacancies is readily controlled by altering the ambient oxygen pressure while annealing the crystals at 1673 0 K. It was found that neither of the three lifetimes observed or their relative intensities varied significantly with the oxygen pressure, and the bulk rate only increased slightly when the specimen was cooled from room to liquid-helium temperatures. These results are interpreted as indicating that some of the positrons are trapped by the existing cation vacancies and a smaller fraction by vacancy clusters

  14. Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, Donald Kent [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-28

    When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutron up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.

  15. Implementation of On-the-Fly Doppler Broadening in MCNP5 for Multiphysics Simulation of Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    William Martin

    2012-11-16

    A new method to obtain Doppler broadened cross sections has been implemented into MCNP, removing the need to generate cross sections for isotopes at problem temperatures. Previous work had established the scientific feasibility of obtaining Doppler-broadened cross sections "on-the-fly" (OTF) during the random walk of the neutron. Thus, when a neutron of energy E enters a material region that is at some temperature T, the cross sections for that material at the exact temperature T are immediately obtained by interpolation using a high order functional expansion for the temperature dependence of the Doppler-broadened cross section for that isotope at the neutron energy E. A standalone Fortran code has been developed that generates the OTF library for any isotope that can be processed by NJOY. The OTF cross sections agree with the NJOY-based cross sections for all neutron energies and all temperatures in the range specified by the user, e.g., 250K - 3200K. The OTF methodology has been successfully implemented into the MCNP Monte Carlo code and has been tested on several test problems by comparing MCNP with conventional ACE cross sections versus MCNP with OTF cross sections. The test problems include the Doppler defect reactivity benchmark suite and two full-core VHTR configurations, including one with multiphysics coupling using RELAP5-3D/ATHENA for the thermal-hydraulic analysis. The comparison has been excellent, verifying that the OTF libraries can be used in place of the conventional ACE libraries generated at problem temperatures. In addition, it has been found that using OTF cross sections greatly reduces the complexity of the input for MCNP, especially for full-core temperature feedback calculations with many temperature regions. This results in an order of magnitude decrease in the number of input lines for full-core configurations, thus simplifying input preparation and reducing the potential for input errors. Finally, for full-core problems with multiphysics

  16. Revisiting the four-level inverted-Y system under both Doppler-free and Doppler-broadened conditions: an analytical approach

    International Nuclear Information System (INIS)

    Ghosh, Arindam; Islam, Khairul; Bandyopadhyay, Amitava; Bhattacharyya, Dipankar

    2016-01-01

    We report the occurrence of electromagnetically induced transparency (EIT) in the simulated probe response signal for a four-level inverted-Y type system that is being acted upon by a weak coherent probe field, a strong coherent pump field and a coherent repump field. There are two ground energy levels, one intermediate energy level and one uppermost energy level. The weak probe field couples the lowest ground level to the intermediate level whereas the repump field connects the other ground level with the intermediate level. The strong control field couples the intermediate level with the uppermost energy level, thereby forming an inverted-Y type system. The density matrix based theoretical model has been developed and solved analytically for this four-level system and the probe response signal has been simulated at different values of the control and repump Rabi frequencies, control and repump frequency detunings and under both Doppler-free and Doppler-broadened conditions using the parameters of 87 Rb D 2 transition. Extremely low line width (few tens of kHz) for the EIT signal has been noticed under thermal averaging for copropagating probe, control and repump field configuration. The EIT signal is found to be immune to the variation in the control Rabi frequency. (paper)

  17. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    International Nuclear Information System (INIS)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro; Nakai, Katsuhiko

    1998-01-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  18. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Nakai, Katsuhiko

    1998-08-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  19. The importance of signals in the Doppler broadening range for middle-atmospheric microwave wind and ozone radiometry

    Science.gov (United States)

    Rüfenacht, Rolf; Kämpfer, Niklaus

    2017-09-01

    Doppler microwave radiometry is a novel technique for the measurement of horizontal wind profiles at altitudes between 10 and 0.03 hPa, where there is a substantial lack of observations. All wind radiometers currently in use rely on ground-based observations of microwave radiation emitted by atmospheric ozone. Besides the well-known primary ozone layer in the stratosphere a secondary ozone layer forms near 10-3 hPa during nighttime. We show that the emission signal of this secondary ozone layer cannot be neglected for the retrieval of mesospheric winds and that it can even alter nighttime ozone retrievals. However, the present study also demonstrates that with a reasonably adequate representation of the atmospheric reality in the mesopause region bias-free wind retrievals throughout the entire sensitive altitude range of the instruments can be achieved during day and nighttime. By applying the improved ozone a priori setup to real observation data the average zonal wind difference to models was substantially reduced and a realistic diurnal cycle was reproduced. Moreover the presence of the high nighttime mesopause ozone signal could enable future retrievals of mean winds beyond the altitude range dominated by pressure broadening.

  20. Positron annihilation lifetime and Doppler broadening study in 50 MeV Li{sup 3+} ion irradiated polystyrene films

    Energy Technology Data Exchange (ETDEWEB)

    Asad Ali, S., E-mail: asadapd@yahoo.co [Department of Applied Physics, Faculty of Engineering and Technology, Aligarh Muslim University, Aligarh 202002 (India); Kumar, Rajesh [Department of Physics, University School of Basic and Applied Sciences, G.G.S.I.P University, New Delhi 110403 (India); Nambissan, P.M.G. [Saha Institute of Nuclear Physics, 1/AF, Bidhan Nagar, Kolkata 700064 (India); Singh, F. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Prasad, Rajendra [Department of Applied Physics, Faculty of Engineering and Technology, Aligarh Muslim University, Aligarh 202002 (India); Vivekananda College of Technology and Management, Aligarh 202002 (India)

    2010-06-15

    Swift heavy ion (SHI) irradiation of polymeric materials results in the change of their free volume properties which have strong correlation with their macroscopic properties. The modification depends on the polymer and ion beam parameters, namely ion energy, fluence and ion species. Polystyrene films were irradiated with Li{sup 3+} ions of energy 50 MeV from 15 UD Pelletron accelerators at Inter University Accelerator Centre (IUAC), New Delhi, India to the fluences of 10{sup 11}, 10{sup 12} and 10{sup 13} ions/cm{sup 2}. Nanosized free volume parameters in the polymer have been studied by positron annihilation lifetime spectroscopy (PALS) and Doppler broadening spectroscopy (DBS). From o-Ps lifetime {tau}{sub 3,} free volume hole radius, mean free volume of microvoids and fractional free volume are computed and modification in free volume with the fluence is studied. Free volume parameters change slowly with ion fluence with a decrease at the highest fluence of 10{sup 13} ions/cm{sup 2}. The decrease in {tau}{sub 3} and I{sub 3} (reflecting the number of free volume holes) may be interpreted on the process of cross-linking. S parameter obtained from DBS measurements showed a minor decrease with increasing fluence.

  1. Positron annihilation Doppler broadening measurement for bulk amorphous alloy by using high energy positron generated from LCS gamma-ray at NEW SUBARU

    Science.gov (United States)

    Hori, F.; Ueno, Y.; Ishii, K.; Ishiyama, T.; Iwase, A.; Miyamoto, S.; Terasawa, T.

    2016-01-01

    A simple positron annihilation measurement apparatus via pair creation has been developed using high energetic gamma beam generated by laser Compton scattering (LCS) of 1 GeV electrons circulated in a storage ring and laser light with the power more than 1 W at the New SUBARU synchrotron radiation facility, University of Hyogo. This MeV ordered energy changeable positron apparatus is useful to study defects in bulk materials. In this study, the average energy of 8MeV positron was selected by the wavelength of laser light and circulated electron energy in photon factory. As a demonstrate of non-destruction positron measurement by this apparatus, positron annihilation Doppler broadening measurement has performed for bulk size of amorphous and crystal structured Zr based alloys. The larger Doppler broadening S parameter for amorphous alloy than that for crystallized one has been successfully measured.

  2. Doppler-broadened NICE-OHMS beyond the cavity-limited weak absorption condition - I. Theoretical description

    Science.gov (United States)

    Ma, Weiguang; Silander, Isak; Hausmaninger, Thomas; Axner, Ove

    2016-01-01

    Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) is conventionally described by an expression (here referred to as the CONV expression) that is restricted to the case when the single-pass absorbance, α0L, is much smaller than the empty cavity losses, π/F [here termed the conventional cavity-limited weak absorption (CCLWA) condition]. This limits the applicability of the technique, primarily its dynamic range and calibration capability. To remedy this, this work derives extended descriptions of Db NICE-OHMS that are not restricted to the CCLWA condition. First, the general principles of Db NICE-OHMS are scrutinized in some detail. Based solely upon a set of general assumptions, predominantly that it is appropriate to linearize the Beer-Lambert law, that the light is modulated to a triplet, and that the Pound-Drever-Hall sidebands are fully reflected, a general description of Db NICE-OHMS that is not limited to any specific restriction on α0L vs. π/F, here referred to as the FULL description, is derived. However, this description constitutes a set of equations to which no closed form solution has been found. Hence, it needs to be solved numerically (by iterations), which is inconvenient. To circumvent this, for the cases when α0L<π/F but without the requirement that the stronger CCLWA condition needs to be fulfilled, a couple of simplified extended expressions that are expressible in closed analytical form, referred to as the extended locking and extended transmission description, ELET, and the extended locking and full transmission description, ELFT, have been derived. An analysis based on simulations validates the various descriptions and assesses to which extent they agree. It is shown that in the CCLWA limit, all extended descriptions revert to the CONV expression. The latter one deviates though from the extended ones for α0L around and above 0.1π/F. The two simplified extended descriptions agree

  3. NDT oriented equipment for observing the Doppler broadening of radiation produced by the annihilation of positrons in cylindrical samples

    International Nuclear Information System (INIS)

    Coleman, C.F.; Smith, F.A.; Hughes, A.E.

    1976-11-01

    This report describes the development of equipment for measuring annihilation line broadening in cylindrical samples a few millimetres in diameter, suitable for use in fatigue testing programs. A detached positron source is employed, allowing the samples to be scanned both longitudinally (resolution approximately 1 cm) and in azimuth. Some of the advantages of and problems associated with this configuration are discussed. The statistical precision of a number of parameters

  4. Coincidence Doppler broadening and 3DAP study of the pre-precipitation stage of an Al-Li-Cu-Mg-Ag alloy

    International Nuclear Information System (INIS)

    Honma, T.; Yanagita, S.; Hono, K.; Nagai, Y.; Hasegawa, M.

    2004-01-01

    Pre-precipitation solute clustering in Al-Li-Cu-Mg-Ag and Al-Cu-Mg-Ag alloys has been investigated by coincidence Doppler broadening (CDB) spectroscopy of positron annihilation and three-dimensional atom probe (3DAP) analysis. Although Ag-Mg co-clusters form in the Al-Cu-Mg-Ag alloy in the early stage of aging, no evidence for the co-cluster formation was obtained from the Li containing alloy using 3DAP. While CDB spectra indicated that vacancies are associated with Ag after aging for 15 s in the Al-Cu-Mg-Ag alloy, vacancy-Ag association is suppressed in the Li containing alloy. Based on the 3DAP and CDB results, the reasons for the completely different clustering behaviors observed in these two similar alloys are discussed

  5. Conjugating precision and acquisition time in a Doppler broadening regime by interleaved frequency-agile rapid-scanning cavity ring-down spectroscopy

    Science.gov (United States)

    Gotti, Riccardo; Gatti, Davide; Masłowski, Piotr; Lamperti, Marco; Belmonte, Michele; Laporta, Paolo; Marangoni, Marco

    2017-10-01

    We propose a novel approach to cavity-ring-down-spectroscopy (CRDS) in which spectra acquired with a frequency-agile rapid-scanning (FARS) scheme, i.e., with a laser sideband stepped across the modes of a high-finesse cavity, are interleaved with one another by a sub-millisecond readjustment of the cavity length. This brings to time acquisitions below 20 s for few-GHz-wide spectra composed of a very high number of spectral points, typically 3200. Thanks to the signal-to-noise ratio easily in excess of 10 000, each FARS-CRDS spectrum is shown to be sufficient to determine the line-centre frequency of a Doppler broadened line with a precision of 2 parts over 1011, thus very close to that of sub-Doppler regimes and in a few-seconds time scale. The referencing of the probe laser to a frequency comb provides absolute accuracy and long-term reproducibility to the spectrometer and makes it a powerful tool for precision spectroscopy and line-shape analysis. The experimental approach is discussed in detail together with experimental precision and accuracy tests on the (30 012) ← (00 001) P12e line of CO2 at ˜1.57 μm.

  6. ESR, thermoelectrical and positron annihilation Doppler broadening studies of CuZnFe2O4-BaTiO3 composite

    International Nuclear Information System (INIS)

    Hemeda, O.M.; Mahmoud, K.R.; Sharshar, T.; Elsheshtawy, M.; Hamad, Mahmoud A.

    2017-01-01

    Composite materials of Cu 0.6 Zn 0.4 Fe 2 O 4 (CZF) and barium titanate (BT) with different concentrations were prepared by high energy ball milling method. The composite samples of CZF and BT were studied using Infrared, ESR and positron annihilation Doppler broadening (PADB) spectroscopy techniques as well as thermo-electric power measurements. The results confirm formation of the composite, and presence of two ferrimagnetic and ferroelectric phases, simultaneously. In addition, Fe–O bond for both tetrahedral and octahedral sites, population and distribution of cations at A and B sites are varied with BT content. The values of resonance field, line width of ESR spectrum and charge carrier concentration increase by increasing BT content. The value of the g factor for our samples with low BT content is greater than g-factor value of the isolated free electron. On the contrary, the g-factor values for samples with high BT content are smaller than the free isolated electron. PADB line-shape S-parameter suggests that there are increases of the density of the delocalized electrons, defect size and concentration caused by highly adding BT phase. In addition, PADB results confirm the homogeneity of composite phases and same structure of defects in BT-CZF composite samples. - Highlights: • Composite materials of Cu 0.6 Zn 0.4 Fe 2 O 4 (CZF) and barium titanate (BT) were prepared. • The resonance field and charge carrier concentration increase by increasing BT. • there is increase of the density of delocalized electrons by highly adding BT. • In addition, PADB results confirm the homogeneity of composite phases.

  7. Design of measurement system for Doppler broadening profiles of annihilation radiations as a function of controlled specimen temperature and its applications for a study of metals in the thermal equilibrium state

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Kawano, Takao.

    1992-01-01

    The measurement system for Doppler broadening profiles of annihilation radiation was developed. This system reads out data for energies of γ-rays from an analog to digital converter and those for specimen temperature from a digital-voltmeter coupled to a thermocouple. These two types of digital-quantities were stored in a memory matrix of 512 channels (energy) x 128 channels (temperature) x 4 byte (count). For this purpose, a memory board of 256 kbyte with 32-dynamic RAMs (64 kbits) was used. The data acquisition was controlled by a microcomputer. Temperature of the specimen was controlled by a programmable temperature controller, thus it can be varied in a desired way. This was useful for measurements in repeated temperature cycles. A sample heater with a compact size was developed in order to obtain a homogeneous temperature distribution in the specimen. Application of this system for a study of thermal vacancies in Al-dilute alloys was also shown. (author)

  8. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  9. Broaden Students' Music Preferences.

    Science.gov (United States)

    Le Blanc, Albert

    1983-01-01

    A model of music preference theory suggests ways that teachers can broaden their students' musical preferences. Teachers can change preferences by changing something in the listener, the social environment, the music, or the ways that the listener processes information. (AM)

  10. Doppler lidar results from the San Gorgonio Pass experiments

    Science.gov (United States)

    Cliff, W. C.; Skarda, J. R.; Renne, D. S.

    1984-01-01

    During FY-84, the Doppler Lidar data from the San Gorgonio Pass experiments were analyzed, evaluated, and interpreted with regard to signal strength, signal width, magnitude and direction of velocity component and a goodness parameter associated with the expected noise level of the signal. From these parameters, a screening criteria was developed to eliminate questionable data. For the most part analysis supports the validity of Doppler Lidar data obtained at San Gorgonio Pass with respect to the mean velocity magnitude and direction. The question as to whether the Doppler width could be interpreted as a measure of the variance of the turbulence within the Doppler Lidar System (DLS) focal volume was not resolved. The stochastic nature of the Doppler broadening from finite residence time of the particles in the beam as well as other Doppler broadening phenomenon tend to mask the Doppler spread associated with small scale turbulence. Future tests with longer pulses may assist in better understanding.

  11. Line broadening by focusing

    International Nuclear Information System (INIS)

    Brito, A.L. de; Jabs, A.

    1983-01-01

    It is pointed out that the spectral width of a quasi-monochromatic light beam broadens when the beam is focused. A quantitative formula for this broadening is derived from classical wave theory. The effect is shown to explain some experiments on laser beams done by E. Panarella which that author has explained under the ad-hoc hypothesis that the frequency of the photons changes along with the intensity of the light beam. The line broadening by focusing might also contribute to gas ionization by incident light when the ionization potential is well above the mean photon energy. Some remarks are made on some direct applications of the Heisenberg relations in comparison with our treatment. (Author) [pt

  12. Deconvolution of shift-variant broadening for Compton scatter imaging

    International Nuclear Information System (INIS)

    Evans, Brian L.; Martin, Jeffrey B.; Roggemann, Michael C.

    1999-01-01

    A technique is presented for deconvolving shift-variant Doppler broadening of singly Compton scattered gamma rays from their recorded energy distribution. Doppler broadening is important in Compton scatter imaging techniques employing gamma rays with energies below roughly 100 keV. The deconvolution unfolds an approximation to the angular distribution of scattered photons from their recorded energy distribution in the presence of statistical noise and background counts. Two unfolding methods are presented, one based on a least-squares algorithm and one based on a maximum likelihood algorithm. Angular distributions unfolded from measurements made on small scattering targets show less evidence of Compton broadening. This deconvolution is shown to improve the quality of filtered backprojection images in multiplexed Compton scatter tomography. Improved sharpness and contrast are evident in the images constructed from unfolded signals

  13. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  14. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  15. Repetitive display system of line profiles for Doppler broadening measurement

    International Nuclear Information System (INIS)

    Mohri, A.; Narihara, K.; Haba, K.

    1982-10-01

    Line profiles of impurities in visible and ultraviolet regions are repetitively displayed on a CRT with an interval of 250 mu s or 500 mu s, using a system composed of a Czerny-Turner monochromator with 1 m F.L., a self-resonant optical scanner, a photomultiplier shielded against hard X-rays and electronic circuits. The profile resolution is 0.035 nm FWHM. This system can be used in the environment of strong hard X-rays. (author)

  16. Electromagnetically-induced transparency in Doppler-broadened ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... Azeem B Mirza Suneel Singh. Contributed Papers Volume 82 Issue 2 February 2014 pp 295-300 ... Abstract. We study electromagnetically-induced transparency (EIT) of a probe field in a Dopplerbroadened five-level K-type atomic system driven by three strong laser (coupling) fields. Effect of wave-vector ...

  17. Electromagnetically-induced transparency in Doppler-broadened ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... Nowadays there is considerable interest in the study of EIT in multilevel atomic systems formed by including extra, optical fields driven resonant transitions, .... Yet we find that the EIT response of the composite system can be dramatically distinct and more complicated than those of the constituent systems.

  18. Quantitative absorption spectroscopy of residual water vapor in high-purity gases: pressure broadening of the 1.39253-microm H2O transition by N2, HCl, HBr, Cl2, and O2.

    Science.gov (United States)

    Vorsa, Vasil; Dheandhanoo, Seksan; Ketkar, Suhas N; Hodges, Joseph T

    2005-02-01

    We determined the respective pressure-broadening coefficients of HCl, HBr, Cl2, and O2 (expressed relative to that of the reference gas N2) for the (v1,v2,v3)J(Ka,Kc) = (0,0,0)3(0,3) --> (1,0,1)2(0,2) rovibrational transition of H2 16O that occurs at 1.39253 microm. The experiment used a continuous-wave cavity ring-down spectroscopy analyzer to measure the peak absorption losses as a function of added moisture concentration. The measured pressure-broadening coefficients for HCl, HBr, Cl2, and O2 are, respectively, 2.76, 2.48, 1.39, and 0.49 times that of the N2 pressure-broadening coefficient, and detection limits for water vapor range from 0.22 nmol mol(-1) for O2 matrix gas to 2.3 nmol mol(-1) for HBr matrix gas. The degradation of the detection limit (relative to the N2 matrix gas) is ascribed to a pressure-broadening-induced reduction in peak absorption cross section and to elevated background loss from the matrix gas.

  19. The doppler ultrasound. La ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Contreras Cecilia, E.; Lozano Setien, E.; Hernandez Montero, J.; Ganado Diaz, T.; Jorquera Moya, M.; Blasco Pascual, E. (Hospital Universitario San Carlos. Madrid (Spain))

    1994-01-01

    The discovery and development of Doppler ultrasound has had a great influence on Medical practice since it allows the noninvasive study of vascular pathology, both arterial and venous, as well as the flow patterns of the different parenchyma. This article deals with the principles, limitations and interpretation of the Doppler signal, as well as the different Doppler ultrasound systems routinely employed in Medicine.

  20. Broadening nanotechnology's impact on development

    NARCIS (Netherlands)

    Beumer, K.

    2016-01-01

    Discussions about nanotechnology and development focus on applications that directly address the needs of the world’s poor. Nanotechnology can certainly make an impact in the fight against global poverty, but we need to broaden our imagination.

  1. Broadening nanotechnology's impact on development

    Science.gov (United States)

    Beumer, Koen

    2016-05-01

    Discussions about nanotechnology and development focus on applications that directly address the needs of the world's poor. Nanotechnology can certainly make an impact in the fight against global poverty, but we need to broaden our imagination.

  2. Rubidium Atomic Line Filtered (RALF) Doppler Velocimetry

    Science.gov (United States)

    Fajardo, Mario; Molek, Christopher; Vesely, Annamaria; Lasem Team

    2013-06-01

    We report our progress towards adapting the well-known Global Dopper Velocimetry (GDV) technique, popular in the aerodynamics community, to the order-of-magnitude higher velocities pertinent to shock experiments. In GDV, the narrow-line illumination laser is tuned to an edge of a molecular iodine absorption line; an iodine gas cell converts the Doppler shift of the reflected light to transmitted intensity. We follow the suggestion in the original 1990 patent by Komine and broaden the absorption lines of alkali metal atoms by adding a buffer gas, thereby tuning the transmission edge spectrum to match the Doppler shift (surface velocity) range of interest. We use atomic rubidium vapor cells, with 0 to 1 atmosphere pressures of molecular nitrogen buffer gas, and coin the name ``Rubidium Atomic Line Filtered'' (RALF) Doppler velocimetry. [96ABW-2013-0036

  3. Broadening of the Measured Frequency Spectrum in a Differential Laser Anemometer due to Interference Plane Gradients

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner

    1973-01-01

    It is shown how an inaccurate alignment of a differential laser anemometer may cause a significant broadening of the Doppler spectrum. The reason is the appearance of gradients in the interference pattern in the measuring volume. The phenomenon was investigated theoretically, and a method...

  4. Spectral broadening of acoustic tones generated by unmanned aerial vehicles in a turbulent atmosphere

    DEFF Research Database (Denmark)

    Ostashev, Vladimir E.; Wilson, D. K.; Finn, Anthony

    2016-01-01

    to atmospheric turbulence is studied. The broadening results from the combined Doppler effect of multiply scattered acoustic signals propagating in a non-stationary turbulent atmosphere. It can be assessed as a Fourier transform of the temporal coherence function of a monochromatic signal propagating...

  5. Broadening the spectrum through curriculum

    International Nuclear Information System (INIS)

    Engel-Hills P

    2006-01-01

    Radiography has experienced changes and challenges from a number of sources. The rapid technological changes in imaging an radiation treatment, changes in the professional context and social transformation have had an impact on the shape and structure of the radiography curriculum. It too must change to prepare graduates for the broadening radiography spectrum

  6. The Doppler paradigm and the APEX-EPOS-ORANGE quandary

    International Nuclear Information System (INIS)

    Griffin, J.J.

    1995-01-01

    The experimental detection of the sharp lines of the (e + e - ) Puzzle is viewed as a struggle against Doppler broadening. Gedanken experiments which are realistic in zeroth order of detail are analyzed to show that the ORANGE and EPOS/I geometries select narrower slices of a Doppler broadened line than spherically inclusive (APEX and EPOS/II -like) apparati. Roughly speaking, the latter require event-by-event Doppler reconstruction simply to regain an even footing with the former. This suggests that APEX' or EPOS/II's coincident pair distributions must be statistically superior to those of EPOS/I or ORANGE in order to support a comparable inference about sharp structure. Under such circumstances, independent alternative data is invaluable. Therefore, a corroboration of Sakai's 330.1 keV ( + or e - bombardments of U and Th targets could prove crucial

  7. Hydrogen Stark Broadened Brackett lines

    Directory of Open Access Journals (Sweden)

    C. Stehlé

    2010-01-01

    Full Text Available Stark-broadened lines of the hydrogen Brackett series are computed for the conditions of stellar atmospheres and circumstellar envelopes. The computation is performed within the Model Microfield Method, which includes the ion dynamic effects and makes the bridge between the impact limit at low density and the static limit at high density and in the line wings. The computation gives the area normalized line shape, from the line core up to the static line wings.

  8. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  9. Advances in Doppler OCT

    Science.gov (United States)

    Liu, Gangjun; Chen, Zhongping

    2014-01-01

    We review the principle and some recent applications of Doppler optical coherence tomography (OCT). The advances of the phase-resolved Doppler OCT method are described. Functional OCT algorithms which are based on an extension of the phase-resolved scheme are also introduced. Recent applications of Doppler OCT for quantification of flow, imaging of microvasculature and vocal fold vibration, and optical coherence elastography are briefly discussed. PMID:24443649

  10. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  11. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  12. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  13. Pulsed multigated Doppler ultrasonography in the diagnosis of carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Bitsch, K R; Schroeder, T

    1988-01-01

    To evaluate the accuracy of a pulsed multigated Doppler system, 128 carotid arteries were examined. The spectral broadening index was calculated from the power spectrum of a small sample volume located in the center of the stream according to the flow profile and was related to the degree of sten...... by a multigated Doppler system may add valuable information concerning blood flow characteristics not obtainable by single-gated systems....

  14. 3D atom microscopy in the presence of Doppler shift

    Science.gov (United States)

    Rahmatullah; Chuang, You-Lin; Lee, Ray-Kuang; Qamar, Sajid

    2018-03-01

    The interaction of hot atoms with laser fields produces a Doppler shift, which can severely affect the precise spatial measurement of an atom. We suggest an experimentally realizable scheme to address this issue in the three-dimensional position measurement of a single atom in vapors of rubidium atoms. A three-level Λ-type atom–field configuration is considered where a moving atom interacts with three orthogonal standing-wave laser fields and spatial information of the atom in 3D space is obtained via an upper-level population using a weak probe laser field. The atom moves with velocity v along the probe laser field, and due to the Doppler broadening the precision of the spatial information deteriorates significantly. It is found that via a microwave field, precision in the position measurement of a single hot rubidium atom can be attained, overcoming the limitation posed by the Doppler shift.

  15. Charge Correlations in Plasma Line Broadening

    International Nuclear Information System (INIS)

    Wrighton, Jeffrey M.; Dufty, James W.

    2008-01-01

    The traditional theory of plasma line broadening is re-examined to correct for phenom-enological assumptions regarding charge correlations. Conditions for static ions are assumed, and the ion microfield distribution is introduced without neglecting ion-electron correlations, and with a precise definition for the ion field at the radiator. Radiator and plasma subsystems are defined so as to make a second order calculation of electron broadening valid for the case of high Z radiators. The electron broadening operator is identified in terms of the fluctuation of the electron density at the radiator, averaged over the entire plasma constrained by a given value for the ion microfield.

  16. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  17. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  18. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  19. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  20. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  1. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  2. Sound pulse broadening in stressed granular media.

    Science.gov (United States)

    Langlois, Vincent; Jia, Xiaoping

    2015-02-01

    The pulse broadening and decay of coherent sound waves propagating in disordered granular media are investigated. We find that the pulse width of these compressional waves is broadened when the disorder is increased by mixing the beads made of different materials. To identify the responsible mechanism for the pulse broadening, we also perform the acoustic attenuation measurement by spectral analysis and the numerical simulation of pulsed sound wave propagation along one-dimensional disordered elastic chains. The qualitative agreement between experiment and simulation reveals a dominant mechanism by scattering attenuation at the high-frequency range, which is consistent with theoretical models of sound wave scattering in strongly random media via a correlation length.

  3. Spectral broadening of VLF transmitter signals and sideband structure observed on Aureol 3 satellite at middle latitudes

    International Nuclear Information System (INIS)

    Tanaka, Y.; Hayakawa, M.; Lagoutte, D.; Lefeuvre, F.; Tajima, S.

    1987-01-01

    Electric and magnetic field wave data acquired on Aureol 3 satellite demonstrate the existence of a spectral broadening effect in which VLF transmitter signals from Alpha station (geographic coordinates, 50.5 degree N, 137 degree E) in USSR undergo a significant spectral broadening on electric fields as they propagate through the ionosphere up to the spacecraft in the altitude range of 500-2,000 km at middle latitudes (L ∼ 2). The spectral broadening phenomena may be divided into two types: (1) spectrally broadened components occurring without any association with ELF/VLF emissions under disturbed ionospheric conditions and (2) spectrally broadened components with predominant sideband structure in association with ELF emissions. Bicoherence computation results suggest a nonlinear mode coupling between the transmitter signal and ELF emission which produces sidebands that are quasi-electrostatic in nature. However, faint spectral broadened components in both types 1 and 2 may be connected with Doppler shift of quasi-electrostatic whistler mode waves with a broad spectrum of k near the resonance cone, due to scattering of the transmitter signals from ionospheric irregularities in the F region

  4. Broadening Our View of Linguistic Diversity

    Science.gov (United States)

    O'Neal, Debra; Ringler, Marjorie

    2010-01-01

    The definition of English language learners needs to be broadened to include the marginalized dialects of English. Not all native speakers speak Standard English, and even those who do need to learn Academic English to succeed in school. By using strategies developed for ELLs, teachers can help all students become fluent in the language of school.

  5. Line-Broadening in Low-Temperature Solid-State NMR Spectra of Fibrils

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Thomas; Dotta, Claudio; Balacescu, Livia; Gath, Julia; Hunkeler, Andreas [ETH Zurich, Physical Chemistry (Switzerland); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [Université de Lyon 1, Institut de Biologie et Chimie des Protéines, UMR 5086 CNRS (France); Meier, Beat H., E-mail: beme@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland)

    2017-01-15

    The temperature-dependent resonance-line broadening of HET-s(218–289) in its amyloid form is investigated in the range between 110 K and 280 K. Significant differences are observed between residues in the structured hydrophobic triangular core, which are broadened the least and can be detected down to 100 K, and in the solvent-exposed parts, which are broadened the most and often disappear from the observed spectrum around 200 K. Below the freezing of the bulk water, around 273 K, the protein fibrils are still surrounded by a layer of mobile water whose thickness decreases with temperature, leading to drying out of the fibrils.

  6. Analysis of neutron diffraction peak broadening caused by internal stresses in composite materials

    International Nuclear Information System (INIS)

    Todd, R.I.; Borsa, C.; Derby, B.

    1994-01-01

    Neutron diffraction is an essential tool in the study of internal stresses in composite materials. In most work only the peak shifts caused by the related elastic strains are considered, but other valuable information exists in the form of peak shape changes. The conditions under which the pure diffraction profile of the composite (i.e. the profile when all sources of broadening not caused by the residual stresses are removed) represents the probability distribution of the peak shifts corresponding to the strains are examined. It is shown that in these conditions, the pure diffraction profile has no attributes of particle size broadening (and vice versa), thereby providing a test for the validity of results interpreted in this way. The experimental derivation of measured strain distributions in Al 2 O 3 /SiCp composites using neutron diffraction is described. No apparent particle size broadening was detected, demonstrating the validity of the results, which also satisfied other tests for consistency

  7. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  8. Effect of method and parameters of spectral analysis on selected indices of simulated Doppler spectra.

    Science.gov (United States)

    Kaluzynski, K; Palko, T

    1993-05-01

    The sensitivity of Doppler spectral indices (mean frequency, maximum frequency, spectral broadening index and turbulence intensity) to the conditions of spectral analysis (estimation method, data window, smoothing window or model order) increases with decreasing signal bandwidth and growing index complexity. The bias of spectral estimate has a more important effect on these indices than its variance. A too low order, in the case of autoregressive modeling and minimum variance methods, and excessive smoothing, in the case of the FFT method, result in increased errors of Doppler spectral indices. There is a trade-off between the errors resulting from a short data window and those due to insufficient temporal resolution.

  9. Nonlinear narrow Doppler-free resonances for optical transitions and annihilation radiation of a positronium atom

    International Nuclear Information System (INIS)

    Letokhov, V.S.; Minogin, V.G.

    1976-01-01

    The possibilities of obtaining narrow resonances without the Doppler broadening for transition between the fine structure levels of the ground and first excited states of a positronium atom are considered. An analysis is carried out of the conditions required for observation of the narrow resonances of saturation of single quantum absorption in the 1S-2P transitions and observation of narrow two-photon absorption resonances in the 1S-2S transitions. It is shown that narrow 2γ annihilation radiation lines of a positronium atom may be obtained with a width much smaller than the Doppler one

  10. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  11. Residual deposits (residual soil)

    International Nuclear Information System (INIS)

    Khasanov, A.Kh.

    1988-01-01

    Residual soil deposits is accumulation of new formate ore minerals on the earth surface, arise as a result of chemical decomposition of rocks. As is well known, at the hyper genes zone under the influence of different factors (water, carbonic acid, organic acids, oxygen, microorganism activity) passes chemical weathering of rocks. Residual soil deposits forming depends from complex of geologic and climatic factors and also from composition and physical and chemical properties of initial rocks

  12. Method and system to measure temperature of gases using coherent anti-stokes doppler spectroscopy

    Science.gov (United States)

    Rhodes, Mark

    2013-12-17

    A method of measuring a temperature of a noble gas in a chamber includes providing the noble gas in the chamber. The noble gas is characterized by a pressure and a temperature. The method also includes directing a first laser beam into the chamber and directing a second laser beam into the chamber. The first laser beam is characterized by a first frequency and the second laser beam is characterized by a second frequency. The method further includes converting at least a portion of the first laser beam and the second laser beam into a coherent anti-Stokes beam, measuring a Doppler broadening of the coherent anti-Stokes beam, and computing the temperature using the Doppler broadening.

  13. The ExoMol pressure broadening diet: H2 and He line-broadening parameters

    Science.gov (United States)

    Barton, Emma J.; Hill, C.; Czurylo, M.; Li, H. Y.; Hyslop, A.; Yurchenko, Sergei N.; Tennyson, Jonathan

    2017-12-01

    In a variety of astronomical objects including gas giant (exo-)planets, brown dwarfs and cool stars, molecular hydrogen and helium are the major line broadeners. However, there is currently no systematic source for these parameters, particularly at the elevated temperatures encountered in many of these objects. The ExoMol project provides comprehensive molecular line lists for exoplanet and other hot atmospheres. The ExoMol database has recently been extended to provide additional data including temperature-dependent, pressure-broadening parameters. Here we assemble H2 and He pressure-broadening datasets for the molecules H2O, NH3, SO2, CH4, PH3, HCN and H2CO using available experimental and theoretical studies.

  14. Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin

    OpenAIRE

    Darquié Benoît; Mejri Sinda; Sow Papa Lat Tabara; Lemarchand Cyril; Triki Meriam; Tokunaga Sean K.; Bordé Christian J.; Chardonnet Christian; Daussy Christophe

    2013-01-01

    proceedings of the ICAP 2012 conference (23rd International Conference on Atomic Physics); International audience; Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 µm enables a determination of the Boltzmann constant k B. We report on our latest measurements. By fitting this lineshape to several models which include Dicke...

  15. Action potential broadening in a presynaptic channelopathy

    Science.gov (United States)

    Begum, Rahima; Bakiri, Yamina; Volynski, Kirill E.; Kullmann, Dimitri M.

    2016-07-01

    Brain development and interictal function are unaffected in many paroxysmal neurological channelopathies, possibly explained by homoeostatic plasticity of synaptic transmission. Episodic ataxia type 1 is caused by missense mutations of the potassium channel Kv1.1, which is abundantly expressed in the terminals of cerebellar basket cells. Presynaptic action potentials of small inhibitory terminals have not been characterized, and it is not known whether developmental plasticity compensates for the effects of Kv1.1 dysfunction. Here we use visually targeted patch-clamp recordings from basket cell terminals of mice harbouring an ataxia-associated mutation and their wild-type littermates. Presynaptic spikes are followed by a pronounced afterdepolarization, and are broadened by pharmacological blockade of Kv1.1 or by a dominant ataxia-associated mutation. Somatic recordings fail to detect such changes. Spike broadening leads to increased Ca2+ influx and GABA release, and decreased spontaneous Purkinje cell firing. We find no evidence for developmental compensation for inherited Kv1.1 dysfunction.

  16. Doppler characteristics of sea clutter.

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristics of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.

  17. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  18. Color doppler in clinical cardiology

    International Nuclear Information System (INIS)

    Duncan, W.J.

    1987-01-01

    A presentation of color doppler, which enables physicians to pinpoint problems and develop effective treatment. State-of-the-art illustrations and layout, with color images and explanatory text are included

  19. Inhomogeneous Broadening in Perturbed Angular Correlation Spectroscopy

    Science.gov (United States)

    Bunker, Austin; Adams, Mike; Hodges, Jeffery; Park, Tyler; Stufflebeam, Michael; Evenson, William; Matheson, Phil; Zacate, Matthew

    2009-10-01

    Our research concerns the effect of a static distribution of defects on the net electric field gradient (EFG) within crystal structures. Defects and vacancies perturb the distribution of gamma rays emitted from radioactive probe nuclei within the crystal. These defects and vacancies produce a net EFG at the site of the probe which causes the magnetic quadrupole moment of the nucleus of the probe to precess about the EFG. The net EFG, which is strongly dependent upon the defect concentration, perturbs the angular correlation (PAC) of the gamma rays, and is seen in the damping of the perturbation function, G2(t), in time and broadening of the spectral peaks in the Fourier transform. We have used computer simulations to study the probability distribution of EFG tensor components in order to uncover the concentration dependence of G2(t). This in turn can be used to analyze experimental PAC data and quantitatively describe properties of the crystal.

  20. Photoinduced broadening of cholesteric liquid crystal reflectors

    Science.gov (United States)

    White, Timothy J.; Freer, Alexander S.; Tabiryan, Nelson V.; Bunning, Timothy J.

    2010-04-01

    The selective reflection of cholesteric liquid crystals (CLCs) is well-known and has been utilized in a number of dynamic optical applications. This work presents a novel approach to passively (e.g., all-optically) cue reflection notch broadening in photoresponsive CLC formulations based on high helical twisting power (HTP) bis(azo) chiral dopants. The original reflection bandwidth of approximately 100 nm is increased to as much as 1700 nm, by exposing 36 μm thick cells to UV light. The maximum attainable bandwidth is shown to be a function of cell thickness, light intensity, and strongly related to the HTP of the photoresponsive chiral dopants. An all-optical technique of simultaneous UV and green light exposure is demonstrated to trap the reflection notch at a predetermined position and bandwidth.

  1. Coherent Forward Broadening in Cold Atom Clouds

    Science.gov (United States)

    Sutherland, R. T.; Robicheaux, Francis

    2016-05-01

    It is shown that homogeneous line-broadening in a diffuse cold atom cloud is proportional to the resonant optical depth of the cloud. Further, it is demonstrated how the strong directionality of the coherent interactions causes the cloud's spectra to depend strongly on its shape, even when the cloud is held at constant densities. These two numerical observations can be predicted analytically by extending the single photon wavefunction model. Lastly, elongating a cloud along the line of laser propagation causes the excitation probability distribution to deviate from the exponential decay predicted by the Beer-Lambert law to the extent where the atoms in the back of the cloud are more excited than the atoms in the front. These calculations are conducted at low densities relevant to recent experiments. This work was supported by the National Science Foundation under Grant No. 1404419-PHY.

  2. Phonon broadening in high entropy alloys

    Science.gov (United States)

    Körmann, Fritz; Ikeda, Yuji; Grabowski, Blazej; Sluiter, Marcel H. F.

    2017-09-01

    Refractory high entropy alloys feature outstanding properties making them a promising materials class for next-generation high-temperature applications. At high temperatures, materials properties are strongly affected by lattice vibrations (phonons). Phonons critically influence thermal stability, thermodynamic and elastic properties, as well as thermal conductivity. In contrast to perfect crystals and ordered alloys, the inherently present mass and force constant fluctuations in multi-component random alloys (high entropy alloys) can induce significant phonon scattering and broadening. Despite their importance, phonon scattering and broadening have so far only scarcely been investigated for high entropy alloys. We tackle this challenge from a theoretical perspective and employ ab initio calculations to systematically study the impact of force constant and mass fluctuations on the phonon spectral functions of 12 body-centered cubic random alloys, from binaries up to 5-component high entropy alloys, addressing the key question of how chemical complexity impacts phonons. We find that it is crucial to include both mass and force constant fluctuations. If one or the other is neglected, qualitatively wrong results can be obtained such as artificial phonon band gaps. We analyze how the results obtained for the phonons translate into thermodynamically integrated quantities, specifically the vibrational entropy. Changes in the vibrational entropy with increasing the number of elements can be as large as changes in the configurational entropy and are thus important for phase stability considerations. The set of studied alloys includes MoTa, MoTaNb, MoTaNbW, MoTaNbWV, VW, VWNb, VWTa, VWNbTa, VTaNbTi, VWNbTaTi, HfZrNb, HfMoTaTiZr.

  3. Determination of ion temperatures from Zeeman broadened spectral lines in the edge of Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Klepper, C.C.; Isler, R.C.; Tobin, S.J.; Hogan, J.T. [Oak Ridge National Lab., TN (United States). Fusion Energy Div.; Hess, W.R. [Association EURATOM-CEA sur la Fusion Controlee, St-Paul-lez-Durance (France). Centre d`Etudes de Cadarache

    1994-09-01

    The authors have examined a {sup 3}P {yields} {sup 3}S multiplet of C III in Tore Supra in order to assess the possibility of determining the ion temperatures from transitions where the Zeeman effect cannot be neglected compared to the Doppler broadening. The preliminary studies lead them to believe that with good quality data the temperatures can be determined within about 20% in the 20--30 eV range and within about 50% in the neighborhood of 5 eV by fitting the entire multiplet rather than a semi-isolated feature, even though certain parameters important for the analysis, such as polarization effects of the optics, are not well characterized. In order to quantify these conclusions more precisely, future work will concentrate on developing numerical fitting routines and on examining the validity of the assumption that the distribution function for low ionization stages is Maxwellian.

  4. Determination of ion temperatures from Zeeman broadened spectral lines in the edge of Tore Supra

    International Nuclear Information System (INIS)

    Klepper, C.C.; Isler, R.C.; Tobin, S.J.; Hogan, J.T.; Hess, W.R.

    1994-01-01

    The authors have examined a 3 P → 3 S multiplet of C III in Tore Supra in order to assess the possibility of determining the ion temperatures from transitions where the Zeeman effect cannot be neglected compared to the Doppler broadening. The preliminary studies lead them to believe that with good quality data the temperatures can be determined within about 20% in the 20--30 eV range and within about 50% in the neighborhood of 5 eV by fitting the entire multiplet rather than a semi-isolated feature, even though certain parameters important for the analysis, such as polarization effects of the optics, are not well characterized. In order to quantify these conclusions more precisely, future work will concentrate on developing numerical fitting routines and on examining the validity of the assumption that the distribution function for low ionization stages is Maxwellian

  5. Coherent compounding in doppler imaging.

    Science.gov (United States)

    Ekroll, Ingvild K; Voormolen, Marco M; Standal, Oyvind K-V; Rau, Jochen M; Lovstakken, Lasse

    2015-09-01

    Coherent compounding can provide high frame rates and wide regions of interest for imaging of blood flow. However, motion will cause out-of-phase summation, potentially causing image degradation. In this work the impact of blood motion on SNR and the accuracy of Doppler velocity estimates are investigated. A simplified model for the compounded Doppler signal is proposed. The model is used to show that coherent compounding acts as a low-pass filter on the coherent compounding Doppler signal, resulting in negatively biased velocity estimates. Simulations and flow phantom experiments are used to quantify the bias and Doppler SNR for different velocities and beam-to-flow (BTF) angles. It is shown that the bias in the mean velocity increases with increasing beam-to-flow angle and/or blood velocity, whereas the SNR decreases; losses up to 4 dB were observed in the investigated scenarios. Further, a 2-D motion correction scheme is proposed based on multi-angle vector Doppler velocity estimates. For a velocity of 1.1 v(Nyq) and a BTF angle of 75°, the bias was reduced from 30% to less than 4% in simulations. The motion correction scheme was also applied to flow phantom and in vivo recordings, in both cases resulting in a substantially reduced mean velocity bias and an SNR less dependent on blood velocity and direction.

  6. Detection of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.

    1979-01-01

    It has been suggested that the residual Doppler shift in the precision electromagnetic tracking of spacecraft be used to search for gravitational radiation that may be incident on the Earth-spacecraft system. The influence of a gravitational wave on the Doppler shift is calculated, and it is found that the residual shift is dominated by two terms: one is due to the passage of electromagnetic waves through the gravitational radiation field, and the other depends on the change in the relative velocity of the Earth and the spacecraft caused by the external wave. A detailed analysis is given of the influence of gravitational radiation on a binary system with an orbital size small compared to the wavelength of the incident radiation. It is shown that, as a consequence of the interaction with the external wave, the system makes a transition from one Keplerian orbit into another which, in general, has a different energy and angular momentum. It is therefore proposed to search for such effects in the solar system. Observations of the orbit of an artificial Earth satellite, the lunar orbit, and especially the planetary orbits offer exciting possibilities for the detection of gravitational waves of various wavelengths. From the results of the lunar laser ranging experiment and the range measurement to Mars, certain interesting limits may be established on the frequency of incidence of gravitational waves of a given flux on the Earth-Moon and the Earth-Mars systems. This is followed by a brief and preliminary analysis of the possibility of detecting gravitational radiation by measuring a residual secular Doppler shift in the satellite-to-satellite Doppler tracking of two counterorbiting drag-free spacecraft around the Earth as in the Van Patten-Everitt experiment

  7. General principles of carotid Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Whal [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    Carotid Doppler ultrasonography is a popular tool for evaluating atherosclerosis of the carotid artery. Its two-dimensional gray scale can be used for measuring the intima-media thickness, which is very good biomarker for atherosclerosis and can aid in plaque characterization. The plaque morphology is related to the risk of stroke. The ulceration of plaque is also known as one of the strong predictors of future embolic event risk. Color Doppler ultrasonography and pulse Doppler ultrasonography have been used for detecting carotid artery stenosis. Doppler ultrasonography has unique physical properties. The operator should be familiar with the physics and other parameters of Doppler ultrasonography to perform optimal Doppler ultrasonography studies.

  8. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  9. Resonance broadening in an intense light field

    International Nuclear Information System (INIS)

    Andreev, S.P.; Lisitsa, V.S.

    1977-01-01

    Collisions of identical atoms in a strong resonance radiation field E 0 cosωt, for which the atomic oscillation period is comparable to the collision time of the atoms, are considered. The problem is treated in terms of the simplest two-level atomic model. The problem of light absorption in such collisions is reduced to the problem of inelastic transitions in a three-level compound system of two atoms and an electromagnetic field. Corresponding probabilities and inelastic scattering integral cross sections for transitions between energy levels in such a system are calculated for two extreme cases- the impact (rapid collisions) and the static one (slow collisions). In the general case the cross sections depend nonlinearly on Esub(0). For small Esub(0) as compared to a certain critical Esub(0)* the results are similar to those of the well-known linear theory of resonance broadening. For Esub(0)>>Esub(0)* the absorption in the line wing is found to decrease (with increase of Esub(0)-the medium becomes more ''transparent''). The kinetics of light absorption in the medium of identical atoms with constant absorption capacity is analysed

  10. Effects on doppler profiles in beam-heated plasmas

    International Nuclear Information System (INIS)

    Fussmann, G.

    1988-01-01

    We analyze various effects that can influence ion temperature measurements based on Doppler broadening of impurity lines. Macroscopic effects such as inhomogeneities, plasma rotation and temporal modulations are distinguished from microscopic ones leading to species-dependent temperatures and anisotropy in the impurity distribution functions. There are turbulent effects related to the latter that can also cause deviations from thermodynamic equilibrium among light and heavy impurities. It is found that under neutral-beam-heated JET conditions, all effects should be small and influence the measured ion temperature by less than ∼ 10%. Larger influences could be expected from strongly peaked rotation profiles - for which, however, no indications are found - and high-level turbulence, which appears rather unrealistic, too. (author)

  11. X-ray diffraction broadening effects in metallic alloys

    International Nuclear Information System (INIS)

    Kimmel, G.; Dayan, D.

    1996-01-01

    Although an extensive work had been done in the last decade in the field of line broadening analysis of XRPD there is still little agreement whether this method can be accepted as a characterization tool. The purpose of the present work is to demonstrate that a valuable information can be retrieved from line broadening effects in XRPD. In this work it was focused on the line broadening effects accompanied with typical processes in metallic systems. The following systems were studied:, pure iron, steels, and alloying effects in uranium alloys. The broadening analysis was linked to different variables like hardness, Izod notch toughness, amount of cold work, surface treatment, concentration of additional elements in solid solutions. The Williamson-Hall method was adopted providing fast and global view of resolved 'strain'-'size' effects, considering the entire diffraction spectrum. The size effect was occasionally approved by direct observations of STM or SEM for example. The results of the broadening analysis were well correlated with other measured parameters like toughness and hardness. It was found that alloying in metallic system is sometimes expressed by pure strain effect but cold work results in a mix of strain and size broadening. The complete view of our results lead us to believe that broadening effect can be quantified. Hence, it is recommended to establish a quantitative XRD line broadening analysis method as a novel tool for characterization of metallic materials. (author)

  12. Impact of optical gain broadening on characteristics of response ...

    Indian Academy of Sciences (India)

    In this paper, the dynamics of QD semiconductor lasers is investigated numerically. Large and small signal modulations for various inhomogeneous broadenings have been studied. Computationally, we have solved the rate equation for two-state InAs QD semiconductor lasers and the effect of inhomogeneous broadening ...

  13. Sub-Doppler Spectroscopy of H_3^+

    Science.gov (United States)

    Hodges, James N.; Perry, Adam J.; Siller, Brian M.; McCall, Benjamin J.

    2013-06-01

    Spectroscopy of H_3^+ is of fundamental interest for advancing ab initio efforts to calculate spectra with high precision and accuracy. H_3^+ is the simplest polyatomic ion, which is why it is an excellent benchmark for theory. In order to perform calculations with spectroscopic accuracy, relativistic and non-adiabatic corrections to the Born-Oppenhiemer approximation must be included; calculations with these considerations agree to within hundredths of a wavenumber. Increasing the precision of the calculations further will require a treatment of quantum electrodynamic effects, as has already been implemented for the diatomic case, and testing these calculations will require higher-precision experimental data to guide ab initio calculations. Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy, or NICE-OHVMS, is a highly sensitive, highly precise technique that we have employed to observe transitions in the ν_2 fundamental band of H_3^+. It combines the advantages of cavity enhancement and heterodyne detection with the ion-neutral discrimination afforded by velocity modulation. Combining a cavity with a high power mid-infrared light source, we can saturate rovibrational transitions. The resulting Lamb dips may be fit in order to determine line centers to a much higher precision than is possible for ordinary Doppler broadened profiles. Additionally, a frequency comb is used to surpass the limited accuracy and precision of a wavemeter. Here we present the results from comb calibrated H_3^+ transitions observed via NICE-OHVMS. Precision and accuracy of ˜ 1 MHz were achieved representing the most accurate and precise H_3^+ line list that has been obtained to date. O. L. Polyansky, J. Tennyson, J. Chem. Phys. (1999), 110, 5056--5064. J. Komasa, et al. J. Chem. Theor. Comp. (2011), 7, 3105--3115. B. M. Siller, et al. Opt. Express (2011), 19, 24822--7. K. N. Crabtree, et al. Chem. Phys. Lett. (2012), 551, 1--6.

  14. Concentration dependence of inhomogeneous broadening in perturbed angular correlation spectroscopy

    Science.gov (United States)

    Moreno, Carlos; Hodges, Jeffery A.; Park, Tyler; Stufflebeam, Michael; Evenson, W.; Matheson, P.; Zacate, M. O.

    2008-10-01

    Since real crystals always include defects, the effect of the defects on crystal properties depends on how many defects are present, i.e. on defect concentration. In perturbed angular correlation (PAC), these defects produce damping of the correlation signal in time and broadening of the frequency spectrum. This ``inhomogeneous broadening'' depends quantitatively on defect concentration, so the size of the broadening in a PAC spectrum can be a measure of the concentration of defects. Using simulated PAC spectra and independent component analysis to obtain the probability distribution function for electric field gradient (EFG) components, we have found defect concentration-dependent parameters for the probability functions. This allows us to calculate broadened PAC spectra for any selected defect concentration. It also allows us to fit defect concentration from an experimental PAC spectrum. This work will be applied initially to broadened PAC data from β-Mn, Al-doped β-Mn, and Sr2RuO4.

  15. Micro-Doppler Analysis of Small UAVs

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Prémel Cabic, G.

    2012-01-01

    Coherent radar measures micro-Doppler properties of moving objects. The micro-Doppler signature depends on parts of an object moving and rotating in addition to the main body motion (e.g. rotor blades) and is therefore characteristic for the type of object. In this study, the micro-Doppler signature

  16. Line-RALF Doppler Velocimetry

    Science.gov (United States)

    Fajardo, Mario

    2017-06-01

    We report the successful proof-of-concept demonstration of a 1D spatially-dependent variant of our Rubidium Atomic Line Filtered (RALF) Doppler velocimetry technique, using streak camera detection of laser light reflected from 1-mm-diameter laser-driven flyers traveling at 1 km/s. RALF employs the frequency-dependent near-resonant optical absorption of a heated Rb/N2 gas cell to convert the Doppler shift of reflected 780.24 nm light directly into transmitted light intensity. This approach results in each individual pixel in a RALF image constituting an independent velocity measurement. RALF advantages over conventional interferometric Doppler velocimetry methods include: a time response limited only by the optoelectronic detection system, and facile adaptation for 1D, and even 2D, imaging velocimetry applications. RALF disadvantages include: the direct conversion of image intensity noise into calculated velocity noise, extreme sensitivity to loss of signal upon shock breakout, and poor tolerance of parasitic reflections of unshifted illumination laser light.

  17. Self-phase-modulation induced spectral broadening in silicon waveguides

    Science.gov (United States)

    Boyraz, Ozdal; Indukuri, Tejaswi; Jalali, Bahram

    2004-03-01

    The prospect for generating supercontinuum pulses on a silicon chip is studied. Using ~4ps optical pulses with 2.2GW/cm2 peak power, a 2 fold spectral broadening is obtained. Theoretical calculations, that include the effect of two-photon-absorption, indicate up to 5 times spectral broadening is achievable at 10x higher peak powers. Representing a nonlinear loss mechanism at high intensities, TPA limits the maximum optical bandwidth that can be generated.

  18. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  19. Effect of Pressure Broadening on Emission and Transmission Spectra of H2O Modeled for sub-Neptune/super-Earth exoplanets: An Application to JWST

    Science.gov (United States)

    Gharib Nezhad, Ehsan; Line, Michael R.; Lyons, James R.

    2017-10-01

    Water is the most readily detected molecule over a diverse range of exoplanet properties (solar composition hot-Jupiters to high metallicity super-earths/neptunes). It is also one of the most important sources of opacity that govern radiative energy balance. It is well known that pressure/collisional broadening significantly influences the opacity of a given molecule. Laboratory spectroscopic studies have shown that the line-broadening (i.e. Doppler, Lorentzian) is influence by several factors including temperature, pressure, dipole moment of the broadeners (or bath gases), and the rotational quantum numbers. Since absorption cross-sections (or opacities) are central to both atmospheric modeling and observational research, there is a critical need to investigate the effect of pressure line-broadening on the absorption cross-sections and subsequent influence on observed transmission and emission spectra of transiting exoplanets. Typical data-model comparisons (either forward modeling or retrieval's) generally rely upon pre-computed grids of absorption cross-sections that assume trace molecules are broadened by a solar composition mixture (e.g., mainly H2 and He as a bath gas). However, as the metallicity of a planetary atmosphere increases, as anticipated for smaller planets in the sub-Neptune-Super Earth range, broadening due to other gases (e.g., N2, CO2, H2O, CH4, CO) can become significant and the H2-He broadening is no longer appropriate. In this work, we assess the influence of different background broadeners on the absorption cross-section of water, and subsequent influence on observed transmission/emission spectra. Initial results suggest that the choice of foreign broadener can result in up to a factor of ~5 increase in pressure broadened wings of the absorption cross sections, resulting in a factor of 1.6x reduction in the atmospheric spectral modulation. Such a difference will be detectible in the hi-resolution/SNR spectra anticipated with JWST, and will

  20. Residuation theory

    CERN Document Server

    Blyth, T S; Sneddon, I N; Stark, M

    1972-01-01

    Residuation Theory aims to contribute to literature in the field of ordered algebraic structures, especially on the subject of residual mappings. The book is divided into three chapters. Chapter 1 focuses on ordered sets; directed sets; semilattices; lattices; and complete lattices. Chapter 2 tackles Baer rings; Baer semigroups; Foulis semigroups; residual mappings; the notion of involution; and Boolean algebras. Chapter 3 covers residuated groupoids and semigroups; group homomorphic and isotone homomorphic Boolean images of ordered semigroups; Dubreil-Jacotin and Brouwer semigroups; and loli

  1. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  2. Doppler effects on periodicities in Saturn's magnetosphere

    Science.gov (United States)

    Carbary, J. F.

    2015-11-01

    The magnetosphere of Saturn exhibits a wide variety of periodic phenomena in magnetic fields, charged particles, and radio emissions. The periodicities are observed from a moving spacecraft, so an issue arises about the periodicities being influenced by the Doppler effects. Doppler effects can be investigated using models of the periodicities and then flying the spacecraft through the model, effectively measuring any Doppler phenomena with the simulation. Using 200 days of typical elliptical orbits from the Cassini mission at Saturn, three models were tested: an azimuthal wave (or "searchlight") model, a radial wave (or "pond ripple") model, and a model of an outwardly traveling spiral wave. The azimuthal wave model produced virtually no Doppler effects in the periodicities because its wave vector is nearly perpendicular to the spacecraft trajectory. The radial wave model generated strong Doppler effects of an upshifted and a downshifted signal (a dual period) on either side of the true period, because the wave vector is either parallel or antiparallel to the spacecraft trajectory. Being intermediate to the searchlight and radial waves, the spiral wave produced Doppler effects but only for low wave speeds (<10 RS/h). For higher wave speeds the Doppler effects were not as clear. The Doppler effects can be mitigated by employing only observations beyond ~15 RS where the spacecraft speed is low compared to the wave speed. The observed periodicities over the same 200 day interval do not show evidence of Doppler effects but generally display a single feature at the expected ~10.7 h period.

  3. Doppler Monte Carlo simulations of light scattering in tissue to support laser-Doppler perfusion measurements

    NARCIS (Netherlands)

    de Mul, F.F.M.; Steenbergen, Wiendelt; Greve, Jan

    1999-01-01

    Doppler Monte Carlo (DMC) simulations of the transport of light through turbid media, e.g., tissue, can be used to predict or to interpret measurements of the blood perfusion of tissue by laser‐Doppler perfusion flowmetry. We describe the physical and mathematical background of Doppler Monte Carlo

  4. Simulated models of inhomogeneous broadening in perturbed angular correlation spectroscopy

    Science.gov (United States)

    Hodges, Jeffery A.; Park, Tyler; Stufflebeam, Michael; Evenson, W.; Matheson, P.; Zacate, M. O.

    2008-10-01

    All real crystals have defects such as impurities and vacancies which affect their properties. In perturbed angular correlation (PAC), these defects produce damping of the correlation signal in time and broadening of the frequency spectrum. This broadening is termed ``inhomogeneous broadening'' since it is due to the inhomogeneities (i.e. defects) in the crystal. We have simulated PAC spectra for various concentrations (0.1% to 15%) of randomly distributed defects with a near-neighbor vacancy in simple cubic and face-centered cubic crystal structures. For every particular set of defects, the randomly distributed defects and the near-neighbor vacancy together produce a net electric field gradient (EFG), from which we obtain the PAC spectrum. We then average PAC spectra to study the effects of defect concentration and crystal structure on inhomogeneous broadening as an aid to analyzing experimental data. This work will be applied initially to broadened PAC data from β-Mn, Al-doped β-Mn, and Sr2RuO4.

  5. Beam broadening of polar molecules and clusters in deflection experiments.

    Science.gov (United States)

    Bulthuis, J; Kresin, V V

    2012-01-07

    A beam of rotating dipolar particles (molecules or clusters) will broaden when passed through an electric or magnetic field gradient region. This broadening, which is a common experimental observable, can be expressed in terms of the variance of the distribution of the resulting polarization orientation (the direction cosine). Here, the broadening for symmetric-top and linear rotors is discussed. These two types of rotors have qualitatively different low-field orientation distribution functions, but behave similarly in a strong field. While analytical expressions for the polarization variance can be derived from first-order perturbation theory, for experimental guidance it is important to identify the applicability and limitations of these expressions, and the general dependence of the broadening on the experimental parameters. For this purpose, the analytical results are compared with the full diagonalization of the rotational Stark-effect matrices. Conveniently for experimental estimations, it is found that for symmetric tops, the dependence of the broadening parameter on the rotational constant, the axial ratio, and the field strength remains similar to the analytical expression even outside of the perturbative regime. Also, it is observed that the shape envelope, the centroid, and the width of the orientation distribution function for a symmetric top are quite insensitive to the value of its rotational constant (except at low rotational temperatures).

  6. Airborne Differential Doppler Weather Radar

    Science.gov (United States)

    Meneghini, R.; Bidwell, S.; Liao, L.; Rincon, R.; Heymsfield, G.; Hildebrand, Peter H. (Technical Monitor)

    2001-01-01

    The Precipitation Radar aboard the Tropical Rain Measuring Mission (TRMM) Satellite has shown the potential for spaceborne sensing of snow and rain by means of an incoherent pulsed radar operating at 13.8 GHz. The primary advantage of radar relative to passive instruments arises from the fact that the radar can image the 3-dimensional structure of storms. As a consequence, the radar data can be used to determine the vertical rain structure, rain type (convective/stratiform) effective storm height, and location of the melting layer. The radar, moreover, can be used to detect snow and improve the estimation of rain rate over land. To move toward spaceborne weather radars that can be deployed routinely as part of an instrument set consisting of passive and active sensors will require the development of less expensive, lighter-weight radars that consume less power. At the same time, the addition of a second frequency and an upgrade to Doppler capability are features that are needed to retrieve information on the characteristics of the drop size distribution, vertical air motion and storm dynamics. One approach to the problem is to use a single broad-band transmitter-receiver and antenna where two narrow-band frequencies are spaced apart by 5% to 10% of the center frequency. Use of Ka-band frequencies (26.5 GHz - 40 GHz) affords two advantages: adequate spatial resolution can be attained with a relatively small antenna and the differential reflectivity and mean Doppler signals are directly related to the median mass diameter of the snow and raindrop size distributions. The differential mean Doppler signal has the additional property that this quantity depends only on that part of the radial speed of the hydrometeors that is drop-size dependent. In principle, the mean and differential mean Doppler from a near-nadir viewing radar can be used to retrieve vertical air motion as well as the total mean radial velocity. In the paper, we present theoretical calculations for the

  7. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to hav...

  8. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  9. Evaluation of Moessbauer line diffusion broadening by exponential fit

    International Nuclear Information System (INIS)

    Kucera, Jaroslav; Kucera, Jan

    1978-01-01

    The Moessbauer line broadening measured by R. LINDSEY in α-iron stabilized with vanadium is evaluated by an exponential fit described in the APPENDIX of this paper. By this procedure the low temperature Moessbauer line width GAMMAsub(m) 0 the diffusion frequency factor D 0 and the activation enthalpy ΔH are computed. KNAUER'S and SOERENSEN-TRUMPY'S definitions of the time correlation factor fsub(t), necessary for the D 0 calculation from Moessbauer line broadening, are applied to the Fe-V diluted BCC solid solutions. (author)

  10. Residue processing

    Energy Technology Data Exchange (ETDEWEB)

    Gieg, W.; Rank, V.

    1942-10-15

    In the first stage of coal hydrogenation, the liquid phase, light and heavy oils were produced; the latter containing the nonliquefied parts of the coal, the coal ash, and the catalyst substances. It was the problem of residue processing to extract from these so-called let-down oils that which could be used as pasting oils for the coal. The object was to obtain a maximum oil extraction and a complete removal of the solids, because of the latter were returned to the process they would needlessly burden the reaction space. Separation of solids in residue processing could be accomplished by filtration, centrifugation, extraction, distillation, or low-temperature carbonization (L.T.C.). Filtration or centrifugation was most suitable since a maximum oil yield could be expected from it, since only a small portion of the let-down oil contained in the filtration or centrifugation residue had to be thermally treated. The most satisfactory centrifuge at this time was the Laval, which delivered liquid centrifuge residue and centrifuge oil continuously. By comparison, the semi-continuous centrifuges delivered plastic residues which were difficult to handle. Various apparatus such as the spiral screw kiln and the ball kiln were used for low-temperature carbonization of centrifuge residues. Both were based on the idea of carbonization in thin layers. Efforts were also being made to produce electrode carbon and briquette binder as by-products of the liquid coal phase.

  11. Inverse Doppler Effects in Broadband Acoustic Metamaterials.

    Science.gov (United States)

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-08-31

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with 'flute-like' acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  12. TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

    International Nuclear Information System (INIS)

    Zhang, Y; Stekel, S; Tradup, D; Hangiandreou, N

    2014-01-01

    Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax

  13. Color doppler sonography in thickened gallbladder wall

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1996-11-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes.

  14. Evaluation of beam divergence of a negative hydrogen ion beam using Doppler shift spectroscopy diagnostics

    Science.gov (United States)

    Deka, A. J.; Bharathi, P.; Pandya, K.; Bandyopadhyay, M.; Bhuyan, M.; Yadav, R. K.; Tyagi, H.; Gahlaut, A.; Chakraborty, A.

    2018-01-01

    The Doppler Shift Spectroscopy (DSS) diagnostic is in the conceptual stage to estimate beam divergence, stripping losses, and beam uniformity of the 100 keV hydrogen Diagnostics Neutral Beam of International Thermonuclear Experimental Reactor. This DSS diagnostic is used to measure the above-mentioned parameters with an error of less than 10%. To aid the design calculations and to establish a methodology for estimation of the beam divergence, DSS measurements were carried out on the existing prototype ion source RF Operated Beam Source in India for Negative ion Research. Emissions of the fast-excited neutrals that are generated from the extracted negative ions were collected in the target tank, and the line broadening of these emissions were used for estimating beam divergence. The observed broadening is a convolution of broadenings due to beam divergence, collection optics, voltage ripple, beam focusing, and instrumental broadening. Hence, for estimating the beam divergence from the observed line broadening, a systematic line profile analysis was performed. To minimize the error in the divergence measurements, a study on error propagation in the beam divergence measurements was carried out and the error was estimated. The measurements of beam divergence were done at a constant RF power of 50 kW and a source pressure of 0.6 Pa by varying the extraction voltage from 4 kV to10 kV and the acceleration voltage from 10 kV to 15 kV. These measurements were then compared with the calorimetric divergence, and the results seemed to agree within 10%. A minimum beam divergence of ˜3° was obtained when the source was operated at an extraction voltage of ˜5 kV and at a ˜10 kV acceleration voltage, i.e., at a total applied voltage of 15 kV. This is in agreement with the values reported in experiments carried out on similar sources elsewhere.

  15. Transboundary natural area protection: Broadening the definition of national security

    Science.gov (United States)

    Haven B. Cook

    2007-01-01

    This paper looks at the definition and concept of national security, and examines how the environment is linked with national security. The traditional, state view of national security that guides most foreign policy includes the concepts of military power, sovereignty and geopolitical stability. This paper advocates broadening the definition of security to include...

  16. On the Stark Broadening of Lu III Spectral Lines

    Indian Academy of Sciences (India)

    1Faculty of Humanities and Social Sciences, University of Rijeka, 51000 Rijeka, Croatia. 2Astronomical Observatory, Volgina 7, 11060 Belgrade, Serbia. 3LERMA ..... and complete atomic data needed for the inclusion of Stark broadening mechanism in modeling of CP star and white dwarf atmospheres and synthesis of ...

  17. Line broadening in the PXRD patterns of layered hydroxides: The ...

    Indian Academy of Sciences (India)

    Unknown

    valent hydroxides are replete with structural disorder, and that the excessive and non-uniform broadening of lines in the PXRD patterns is on account of struc- tural disorder rather than due to crystallite size effects. We now extend these studies to another class of layered compounds, the layered double hydroxides. (LDHs).6 ...

  18. Line broadening in the PXRD patterns of layered hydroxides: The ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Layered hydroxides crystallize in a hexagonal structure and incorporate a number of different types of structural disorders as an exigency of anisotropic bonding. Structural disorder contributes to the non-uniform broadening of lines in the powder X-ray diffraction pattern. Common among the disorders are stacking ...

  19. Optical coherent control in semiconductors: Fringe contrast and inhomogeneous broadening

    DEFF Research Database (Denmark)

    Østergaard, John Erland; Vadim, Lyssenko; Hvam, Jørn Märcher

    2001-01-01

    in the interplay between the homogeneous and inhomogeneous broadenings are measured. Based on these experiments, a coherent control model describing the optical fringe contrast using different detection schemes, such as photoluminescence or four-wave mixing, is established. Significant spectral modulation...

  20. Line broadening in the PXRD patterns of layered hydroxides: The ...

    Indian Academy of Sciences (India)

    Layered hydroxides crystallize in a hexagonal structure and incorporate a number of different types of structural disorders as an exigency of anisotropic bonding. Structural disorder contributes to the non-uniform broadening of lines in the powder X-ray diffraction pattern. Common among the disorders are stacking faults, ...

  1. Extending, Broadening and Rethinking Existing Research on Transfer of Training

    Science.gov (United States)

    Volet, Simone

    2013-01-01

    The aim of this Special Issue was to generate a new integrated agenda for research on transfer of training. It brought together scholars from diverse perspectives and invited them to strive toward synergy. This article examines how this collection of articles, as well as other bodies of literature, can help extend, broaden and rethink current…

  2. Broadening the concept of international entrepreneurship: 'Consumers as international entrepreneurs'

    NARCIS (Netherlands)

    Chandra, Y.; Coviello, N.

    2010-01-01

    We integrate theories from international business, entrepreneurship, innovation, marketing and network economics to develop a four-part typology of ‘consumers as international entrepreneurs’. This broadens the concept of international entrepreneurship and complements the firm-level focus customary

  3. The STARS Alliance: Viable Strategies for Broadening Participation in Computing

    Science.gov (United States)

    Dahlberg, Teresa; Barnes, Tiffany; Buch, Kim; Rorrer, Audrey

    2011-01-01

    The Students and Technology in Academia, Research, and Service (STARS) Alliance is a nationally-connected system of regional partnerships among higher education, K-12 schools, industry and the community with a mission to broaden the participation of women, under-represented minorities and persons with disabilities in computing (BPC). Each regional…

  4. Impact of optical gain broadening on characteristics of response ...

    Indian Academy of Sciences (India)

    2017-09-11

    Sep 11, 2017 ... Home; Journals; Pramana – Journal of Physics; Volume 89; Issue 3. Impact of optical gain broadening on characteristics of response function in the presence and absence of tunnelling injection for quantum dot semiconductor lasers. YASIN YEKTA KIA ESFANDIAR RAJAEI. Research Article Volume 89 ...

  5. Quasi-elastic neutron line broadening in nematic liquid crystals

    International Nuclear Information System (INIS)

    Cvikl, B.; Dimic, V.; Dusic, M.; Kristof, E.; Srebotnjak, E.

    1979-01-01

    On the basis of a new random walk torsional oscillations model of the amplitude φ 0 of rigid flat molecules a quasi-elastic neutron line broadening has been calculated and the results compared to the measurements obtained on the sample of cholesteryl propionate. A good agreement was obtained. (author)

  6. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  7. GOLD: Building capacity for broadening participation in the Geosciences

    Science.gov (United States)

    Adams, Amanda; Patino, Lina; Jones, Michael B.; Rom, Elizabeth

    2017-04-01

    The geosciences continue to lag other science, technology, engineering, and mathematics (STEM) disciplines in the engagement, recruitment and retention of traditionally underrepresented and underserved minorities, requiring more focused and strategic efforts to address this problem. Prior investments made by the National Science Foundation (NSF) related to broadening participation in STEM have identified many effective strategies and model programs for engaging, recruiting, and retaining underrepresented students in the geosciences. These investments also have documented clearly the importance of committed, knowledgeable, and persistent leadership for making local progress in broadening participation in STEM and the geosciences. Achieving diversity at larger and systemic scales requires a network of diversity "champions" who can catalyze widespread adoption of these evidence-based best practices and resources. Although many members of the geoscience community are committed to the ideals of broadening participation, the skills and competencies that empower people who wish to have an impact, and make them effective as leaders in that capacity for sustained periods of time, must be cultivated through professional development. The NSF GEO Opportunities for Leadership in Diversity (GOLD) program was implemented in 2016, as a funding opportunity utilizing the Ideas Lab mechanism. Ideas Labs are intensive workshops focused on finding innovative solutions to grand challenge problems. The ultimate aim of this Ideas Lab, organized by the NSF Directorate for Geosciences (GEO), was to facilitate the design, pilot implementation, and evaluation of innovative professional development curricula that can unleash the potential of geoscientists with interests in broadening participation to become impactful leaders within the community. The expectation is that mixing geoscientists with experts in broadening participation research, behavioral change, social psychology, institutional

  8. Hydrogen Balmer Line Broadening in Solar and Stellar Flares

    Energy Technology Data Exchange (ETDEWEB)

    Kowalski, Adam F. [Department of Astrophysical and Planetary Sciences, University of Colorado Boulder, 2000 Colorado Avenue, Boulder, CO 80305 (United States); Allred, Joel C. [NASA/Goddard Space Flight Center, Code 671, Greenbelt, MD 20771 (United States); Uitenbroek, Han [National Solar Observatory, University of Colorado Boulder, 3665 Discovery Drive, Boulder, CO 80303 (United States); Tremblay, Pier-Emmanuel [Department of Physics, University of Warwick, Coventry CV47AL (United Kingdom); Brown, Stephen [School of Physics and Astronomy, Kelvin Building, University of Glasgow, G12 8QQ (United Kingdom); Carlsson, Mats [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Osten, Rachel A. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wisniewski, John P. [Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, 440 W. Brooks Street, Norman, OK 73019 (United States); Hawley, Suzanne L., E-mail: Adam.Kowalski@lasp.colorado.edu [University of Washington Department of Astronomy, 3910 15th Avenue NE, Seattle, WA 98195 (United States)

    2017-03-10

    The broadening of the hydrogen lines during flares is thought to result from increased charge (electron, proton) density in the flare chromosphere. However, disagreements between theory and modeling prescriptions have precluded an accurate diagnostic of the degree of ionization and compression resulting from flare heating in the chromosphere. To resolve this issue, we have incorporated the unified theory of electric pressure broadening of the hydrogen lines into the non-LTE radiative-transfer code RH. This broadening prescription produces a much more realistic spectrum of the quiescent, A0 star Vega compared to the analytic approximations used as a damping parameter in the Voigt profiles. We test recent radiative-hydrodynamic (RHD) simulations of the atmospheric response to high nonthermal electron beam fluxes with the new broadening prescription and find that the Balmer lines are overbroadened at the densest times in the simulations. Adding many simultaneously heated and cooling model loops as a “multithread” model improves the agreement with the observations. We revisit the three-component phenomenological flare model of the YZ CMi Megaflare using recent and new RHD models. The evolution of the broadening, line flux ratios, and continuum flux ratios are well-reproduced by a multithread model with high-flux nonthermal electron beam heating, an extended decay phase model, and a “hot spot” atmosphere heated by an ultrarelativistic electron beam with reasonable filling factors: ∼0.1%, 1%, and 0.1% of the visible stellar hemisphere, respectively. The new modeling motivates future work to understand the origin of the extended gradual phase emission.

  9. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  10. Transrectal ultrasound color Doppler in the evaluation of recurrence of anal canal cancer

    International Nuclear Information System (INIS)

    Drudi, Francesco M.; Giovagnorio, Francesco; Raffetto, Nicola; Ricci, Paolo; Cascone, Fiammetta; Santarelli, Mario; Trippa, Francesca; Passariello, Roberto

    2003-01-01

    Objective: aim was to obtain elements for a differential diagnosis between post-radiation fibrosis and residual tumor or local relapse in anal canal cancer through detection of presence/absence of intralesional blood flow. Transrectal ultrasound and color Doppler were compared. Methods: 43 patients underwent transrectal ultrasound sonography and color Doppler before and after therapy to assess intralesional blood flow and flow pattern (spotty and linear signals). All diagnostic imaging results were compared to histological analysis. Specificity was submitted to statistical analysis using McNemar test. Results: before therapy 34 lesions (79%) showed color signal; no signal in 9 (21%), which were excluded from our analysis. Eighteen of the 34 patients considered, presented complete response to therapy, 14 partial response and two no response. After therapy, signal disappeared in 17 patients (94%); one false-positive (6%) presented spotty signals; 16 of 34 patients presented changed color signal. Color Doppler showed higher specificity than grey scale transrectal ultrasound in the differentiation of fibrosis from tumor. Response was confirmed by histological examination, considered gold standard. McNemar test demonstrated the significance of color Doppler (P<0.0001). Conclusion: color Doppler considerably increases transrectal ultrasound specificity in differentiating tumor relapse from fibrosis in anal canal cancer

  11. Peak broadening in paper chromatography and related techniques : III. Peak broadening in thin-layer chromatography on cellulose powder

    NARCIS (Netherlands)

    Ligny, C.L. de; Remijnse, A.G.

    1968-01-01

    The mechanism of peak broadening in thin-layer chromatography on cellulose powder was investigated by comparing the peak widths obtained in chromatography with those caused only by diffusion in the cellulose powder, for a set of amino acids of widely differing RF values and six kinds of cellulose

  12. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  13. Doppler-free Fourier transform spectroscopy.

    Science.gov (United States)

    Meek, Samuel A; Hipke, Arthur; Guelachvili, Guy; Hänsch, Theodor W; Picqué, Nathalie

    2018-01-01

    Sub-Doppler broadband multi-heterodyne spectroscopy is proposed and experimentally demonstrated. Using two laser frequency combs of slightly different repetition frequencies, we have recorded Doppler-free two-photon dual-comb spectra of atomic rubidium resonances of a width of 6 MHz, while simultaneously interrogating a spectral span of 10 THz. The atomic transitions are uniquely identified via the intensity modulation of the observed fluorescence radiation. To the best of our knowledge, these results represent the first demonstration of Doppler-free Fourier transform spectroscopy and extend the range of applications of broadband spectroscopy towards precision nonlinear spectroscopy.

  14. Residual risk

    African Journals Online (AJOL)

    ing the residual risk of transmission of HIV by blood transfusion. An epidemiological approach assumed that all HIV infections detected serologically in first-time donors were pre-existing or prevalent infections, and that all infections detected in repeat blood donors were new or incident infections. During 1986 - 1987,0,012%.

  15. Laser Doppler detection systems for gas velocity measurement.

    Science.gov (United States)

    Huffaker, R M

    1970-05-01

    The velocity of gas flow has been remotely measured using a technique which involves the coherent detection of scattered laser radiation from small particles suspended in the fluid utilizing the doppler effect. Suitable instrumentation for the study of wind tunnel type and atmospheric flows are described. Mainly for reasons of spatial resolution, a function of the laser wavelength, the wind tunnel system utilizes an argon laser operating at 0.5 micro. The relaxed spatial resolution requirement of atmospheric applications allows the use of a carbon dioxide laser, which has superior performance at a wavelength of 10.6 micro, a deduction made from signal-to-noise ratio considerations. Theoretical design considerations are given which consider Mie scattering predictions, two-phase flow effects, photomixing fundamentals, laser selection, spatial resolution, and spectral broadening effects. Preliminary experimental investigations using the instrumentation are detailed. The velocity profile of the flow field generated by a 1.27-cm diam subsonic jet was investigated, and the result compared favorably with a hot wire investigation conducted in the same jet. Measurements of wind velocity at a range of 50 m have also shown the considerable promise of the atmospheric system.

  16. Plasma magnetic field diagnostic using two-photon Doppler-free LIF

    Science.gov (United States)

    Yoon, Young Dae; Bellan, Paul

    2015-11-01

    A detailed description of a new plasma B field diagnostic using Doppler-free two-photon laser-induced fluorescence is presented. The diagnostic is based on a method previously developed in the context of rubidium vapor experiments. Two counter-propagating 393nm diode laser beams are directed into an argon plasma to excite Ar-II ions from 3s2 3p4 4 s4P1 / 2 ⟶ 3s2 3p4 4 p4S3 / 2 ⟶ 3s2 3p4 4 d4P3 / 2 . These levels involve two similar (392.86 and 393.25nm) transition wavelengths, so the two counter-propagating beams effectively cancel out the Doppler effect. The excited ions then decay to the 3s2 3p4 4 p4P1 / 2 level, emitting a 324.98nm line which is to be detected by a photomultiplier tube. The Zeeman splitting -- normally unobservable because of the large Doppler broadening -- of the resultant fluorescence is then to be analyzed, yielding the magnetic field of the particular location. This method is expected to provide a 3-D localized, non-perturbing measurement of magnetic fields. An experimental implementation is currently in progress.

  17. SCANDI – an all-sky Doppler imager for studies of thermospheric spatial structure

    Directory of Open Access Journals (Sweden)

    A. L. Aruliah

    2010-02-01

    Full Text Available A new all-sky Fabry-Perot Interferometer called the Scanning Doppler Imager (SCANDI was built and installed at Longyearbyen in December 2006. Observations have been made of the Doppler shifts and Doppler broadening of the 630 nm airglow and aurora, from which upper thermospheric winds and temperatures are calculated. SCANDI allows measurements over a field-of-view (FOV with a horizontal radius of nearly 600 km for observations at an altitude of 250 km using a time resolution of 8 min. The instrument provides the ability to observe thermospheric spatial structure within a FOV which overlaps that of the EISCAT Svalbard radar and CUTLASS SuperDARN radars. Coordinating with these instruments provides an important opportunity for studying ion-neutral coupling. The all-sky image is divided into several sectors to provide a horizontal spatial resolution of between 100–300 km. This is a powerful extension in observational capability but requires careful calibration and data analysis, as described here. Two observation modes were used: a fixed and a scanning etalon gap. SCANDI results are corroborated using the Longyearbyen single look direction FPI, and ESR measurements of the ion temperatures. The data show thermospheric temperature gradients of a few Kelvins per kilometre, and a great deal of meso-scale variability on spatial scales of several tens of kilometres.

  18. Uncovering the CH-53E Doppler Myth

    National Research Council Canada - National Science Library

    Lamigo, Dwaine

    2008-01-01

    The CH-53E's Helicopter Night Vision System's (HNVS) doppler generated cuing ability is a valuable asset that can enhance the pilot's situational awareness and mitigate spatial disorientation in low-level maneuvers...

  19. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  20. Moving Sources: Doppler Beats and Mach Cones

    Science.gov (United States)

    Gluck, Paul

    2005-09-01

    This paper describes two experiments involving moving sources. The first one is a class activity for observing beats in a Doppler setup; the second one describes how to observe the transition from "subsonic" to "supersonic" waves in a ripple tank.

  1. Color doppler and power doppler ultrasonography in renal transplant recipients with cytomegalovirus infection

    International Nuclear Information System (INIS)

    Wan Guangsheng; Chen Xionghui; Li Meidi; Shao Zheying; Peng Shubai

    2003-01-01

    Objective: To investigate the features of color Doppler and Doppler ultrasonography of transplanted kidneys in patients with cytomegalovirus infections. Methods: Color Doppler and Power Doppler ultrasonography was used to examine transplanted kidneys in 36 recipients with cytomegalovirus infection. The blood flow area ratios (BFAR), the volumes, the resistive indexes (RI), the peak flow velocities in parenchymal arteries (Vmax) were measured and compared with no complication (normal) cases. Results: BFAR was lower in patients with cytomegalovirus infection than that in no complication (normal) cases (P 0.05). Conclusions: The blood flows of transplanted kidneys were reduced in patients with cytomegalovirus infection. To monitor BFAR of transplanted kidneys was contributed to evaluate management effect

  2. with Ultrasound Color Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2012-01-01

    Full Text Available Color Doppler imaging (CDI can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture.

  3. Dependence of inhomogeneous vibrational linewidth broadening on attractive forces from local liquid number densities

    International Nuclear Information System (INIS)

    George, S.M.; Harris, C.B.

    1982-01-01

    The dependence of inhomogeneous vibrational linewidth broadening on attractive forces form slowly varying local liquid number densities is examined. The recently developed Schweizer--Chandler theory of vibrational dephasing is used to compute absolute inhomogeneous broadening linewidths. The computed linewidths are compared to measured inhomogeneous broadening linewidths determined using picosecond vibrational dephasing experiments. There is a similarity between correlations of the Schweizer--Chandler and George--Auweter--Harris predicted inhomogeneous broadening linewidths and the measured inhomogeneous broadening linewidths. For the methyl stretches under investigation, this correspondence suggests that the width of the number density distribution in the liquid determines the relative inhomogeneous broadening magnitudes

  4. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  5. Defect Concentration Dependence of Inhomogeneous Broadening in PAC Spectroscopy

    Science.gov (United States)

    Adams, Mike; Bunker, Austin; Hodges, Jeffery; Park, Tyler; Stufflebeam, Michael; Evenson, William; Matheson, Phil; Zacate, Matthew

    2009-10-01

    Defects in crystals affect the electric field gradient (EFG) tensor components at radioactive probe nuclei. We consider the net EFG from a random distribution of vacancies combined with a single trapped vacancy in a near neighbor position. The net EFG perturbs angular correlation (PAC) and provides information about the concentration of vacancies. For various concentrations (.1 to 15 percent) we have simulated PAC spectra in simple cubic, body centered and face centered cubic crystal structures. Using the probability distributions we found for the EFG tensor components we reconstruct G2(t) for various defect concentrations. We take these reconstructions and compare them with the simulated G2(t) functions to check for self-consistency. We can then use the simulated probability distributions to examine the concentration dependence of experimental broadened PAC spectra. This work will be applied initially to broadened PAC data from β-Mn, Al-doped β-Mn, and Sr2RuO4.

  6. Positive emotions and the social broadening effects of Barack Obama.

    Science.gov (United States)

    Ong, Anthony D; Burrow, Anthony L; Fuller-Rowell, Thomas E

    2012-10-01

    Past experiments have demonstrated that the cognitive broadening produced by positive emotions may extend to social contexts. Building on this evidence, we hypothesized that positive emotions triggered by thinking about Barack Obama may broaden and expand people's sense of self to include others. Results from an expressive-writing study demonstrated that African American college students prompted to write about Obama immediately prior to and after the 2008 presidential election used more plural self-references, fewer other-references, and more social references. Mediation analyses revealed that writing about Obama increased positive emotions, which in turn increased the likelihood that people thought in terms of more-inclusive superordinate categories (we and us rather than they and them). Implications of these findings for the role of positive emotions in perspective-taking and intergroup relations are considered.

  7. From forensic epigenetics to forensic epigenomics: Broadening DNA investigative intelligence

    OpenAIRE

    Vidaki, Athina; Kayser, Manfred

    2017-01-01

    textabstractHuman genetic variation is a major resource in forensics, but does not allow all forensically relevant questions to be answered. Some questions may instead be addressable via epigenomics, as the epigenome acts as an interphase between the fixed genome and the dynamic environment. We envision future forensic applications of DNA methylation analysis that will broaden DNA-based forensic intelligence. Together with genetic prediction of appearance and biogeographic ancestry, epigenomi...

  8. A method to enhance the resolution of broadened spectra

    Energy Technology Data Exchange (ETDEWEB)

    Cabral P, A.; Jimenez D, H.; Torres V, M.; Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.R.; Lopez E, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Fuentes Z, G.A.; Cordoba, A. [UAM-I, 09340 Mexico D.F. (Mexico)

    1992-02-15

    A deconvolution method to analyze line overlapping broadened spectra is presented. Two approximation expressions from which the user can remove, either a Lorentzian or a Gaussian line from observed spectra are utilized. Moessbauer spectra, EPR and Thermoluminescence spectroscopies are analyzed. It is shown that in each case, the de convolved spectrum may provide valuable data to get a much closer characterization of a substance. (Author)

  9. Line broadening in the neutral and ionized mercury spectra

    Science.gov (United States)

    Gavrilov, M.; Skočić, M.; Burger, M.; Bukvić, S.; Djeniže, S.

    2012-10-01

    The neutral, singly, doubly and triply ionized mercury (Hg I-IV, respectively) spectral line shapes and line center positions have been investigated in the laboratory helium plasma at electron densities ranging between 9.3 × 1022 m-3 and 1.93 × 1023 m-3 and electron temperatures around 19,500 K, both interesting for astrophysics. The mercury (natural isotope composition) atoms were sputtered from the cylindrical amalgamated gold plates located in the homogenous part of the pulsed helium discharge operating at a pressure of 665 Pa in a flowing regime. The mercury spectral line profiles were recorded using the McPherson model 209 spectrograph and the Andor ICCD camera as the detection system. This research presents Stark broadening parameters, the width (W) and the shift (d), of one Hg I, 19 Hg II, 6 Hg III and 4 Hg IV lines, not investigated so far. Our experimental W values were compared with the data calculated applying various approaches. The shape and intensity of astrophysically important 398.4 nm Hg II spectral line was discussed taking into account the isotope shift, hyperfine structure and Penning effects. At the mentioned plasma parameters the Stark broadening is found to be a main line broadening mechanism of the lines (λ > 200 nm) in the Hg I-IV spectra.

  10. Residual basins

    International Nuclear Information System (INIS)

    D'Elboux, C.V.; Paiva, I.B.

    1980-01-01

    Exploration for uranium carried out over a major portion of the Rio Grande do Sul Shield has revealed a number of small residual basins developed along glacially eroded channels of pre-Permian age. Mineralization of uranium occurs in two distinct sedimentary units. The lower unit consists of rhythmites overlain by a sequence of black shales, siltstones and coal seams, while the upper one is dominated by sandstones of probable fluvial origin. (Author) [pt

  11. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    International Nuclear Information System (INIS)

    Wada, M.; Doi, K.; Kisaki, M.; Nakano, H.; Tsumori, K.; Nishiura, M.

    2015-01-01

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum

  12. On the Application of Stark Broadening Data Determined with a Semiclassical Perturbation Approach

    Directory of Open Access Journals (Sweden)

    Milan S. Dimitrijević

    2014-08-01

    Full Text Available The significance of Stark broadening data for problems in astrophysics, physics, as well as for technological plasmas is discussed and applications of Stark broadening parameters calculated using a semiclassical perturbation method are analyzed.

  13. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  14. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  15. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  16. Transient basilar artery occlusion monitored by transcranial color Doppler presenting with a spectacular shrinking deficit: a case report

    Directory of Open Access Journals (Sweden)

    Del Sette Massimo

    2010-01-01

    Full Text Available Abstract Introduction We describe the case of a 79-year-old Caucasian Italian woman with a transient basilar occlusion monitored by transcranial Doppler, with subsequent recanalization and clinical shrinking deficit. This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. This case is important and needs to be reported because transient basilar occlusion may be easily diagnosed if transcranial Doppler is performed. Case presentation A 79-year-old woman affected by chronic atrial fibrillation and not treated with oral anticoagulants, cardioverted to sinus rhythm during a gastric endoscopy. She then showed a sudden-onset loss of consciousness, horizontal and vertical gaze palsy, tetraparesis and bilateral miosis and coma. Two hours later, the symptoms resolved quickly, leaving no residual neurologic deficits. Transcranial Doppler examination showed a dampened flow in the basilar artery in the emergency examination and a restored flow when the symptoms resolved. Conclusion This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. We believe that transcranial Doppler should be performed in all cases of unexplained acute loss of consciousness, in particular, if associated with signs of brainstem dysfunctions.

  17. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  18. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  19. From forensic epigenetics to forensic epigenomics: broadening DNA investigative intelligence.

    Science.gov (United States)

    Vidaki, Athina; Kayser, Manfred

    2017-12-21

    Human genetic variation is a major resource in forensics, but does not allow all forensically relevant questions to be answered. Some questions may instead be addressable via epigenomics, as the epigenome acts as an interphase between the fixed genome and the dynamic environment. We envision future forensic applications of DNA methylation analysis that will broaden DNA-based forensic intelligence. Together with genetic prediction of appearance and biogeographic ancestry, epigenomic lifestyle prediction is expected to increase the ability of police to find unknown perpetrators of crime who are not identifiable using current forensic DNA profiling.

  20. Stark Broadening of Cr III Spectral Lines: DO White Dwarfs

    Directory of Open Access Journals (Sweden)

    Milan S. Dimitrijević

    2018-04-01

    Full Text Available Using the modified semiempirical method of Dimitrijević and Konjević, Stark widths have been calculated for six Cr III transitions, for an electron density of 10 17 cm ‒ 3 and for temperatures from 5000–80,000 K. Results have been used for the investigation of the influence of Stark broadening on spectral lines in cool DO white dwarf atmospheres. Calculated Stark widths will be implemented in the STARK-B database, which is also a part of the Virtual Atomic and Molecular Data Center (VAMDC.

  1. Strategies for broadening public involvement in space developments

    Science.gov (United States)

    Harris, Philip R.

    1992-01-01

    There is widespread public interest in and goodwill toward the space program. For NASA's plans for the next 25 years to be achieved, this public reservoir of support needs to be tapped and channeled. NASA endeavors have to reach out beyond the scientific, technological, and aerospace communities to foster wider participation in space exploration and exploitation. To broaden NASA support and spread out the financing of space activities, recommendations for consideration are offered in the area of economics, political, institutional, international, and managerial areas.

  2. RESIDUAL RISK ASSESSMENTS - RESIDUAL RISK ...

    Science.gov (United States)

    This source category previously subjected to a technology-based standard will be examined to determine if health or ecological risks are significant enough to warrant further regulation for Coke Ovens. These assesments utilize existing models and data bases to examine the multi-media and multi-pollutant impacts of air toxics emissions on human health and the environment. Details on the assessment process and methodologies can be found in EPA's Residual Risk Report to Congress issued in March of 1999 (see web site). To assess the health risks imposed by air toxics emissions from Coke Ovens to determine if control technology standards previously established are adequately protecting public health.

  3. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1996-06-15

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  4. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  5. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  6. Doppler flow patterns in pediatric pulmonary pathology

    International Nuclear Information System (INIS)

    Garcia, J.A.; Valdes, P.; Valls, E.; Alonso, I.; Ceres, L.

    1996-01-01

    To differentiate, in a number of pediatric lung diseases, a series of Doppler flow patterns according to their pulmonary or systemic origin, assessing the morphology of the spectral curve. We have reviewed the Doppler studies carried out in 22 patients with a variety of pulmonary pathologies, including several pulmonary abnormalities: three cases of sequestration, four cases of pulmonary vein drainage problems (one with no evidence of associated pulmonary abnormality, two with scimitar syndrome and one variant with accessory diaphragm), one case of cystic adenomatoid malformation, three cases of metastatic neoplastic lesion, one case of hydatid cyst and 10 cases of infections pathology and atelectasis, the underlying causes of which were unknown. We have found four basis patterns of pulmonary or systemic arterial and venous vascularization in ultrasonographic studies. We conclude that the use of Doppler ultrasound associated with standard ultrasonography is a very helpful tool in the initial diagnosis of pulmonary vascularization abnormalities. (Author)

  7. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  8. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  9. Doppler diagnosis of deep venous thrombosis

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The venous Doppler examination has been shown to be a sensitive test for the diagnosis of deep venous thrombosis. An experienced technologist can perform the examination in about ten minutes at the bedside or in the laboratory. Because the venous Doppler examination is subjective, it requires considerable experience of the examiner to achieve maximal accuracy. Nevertheless, with sufficient practice the technologist may employ this instrument with skill and versatility to detect both obstruction and valvular incompetence in the superficial, communicating, and deep veins of the lower and upper extremities

  10. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  11. Residual nilpotence and residual solubility of groups

    International Nuclear Information System (INIS)

    Mikhailov, R V

    2005-01-01

    The properties of the residual nilpotence and the residual solubility of groups are studied. The main objects under investigation are the class of residually nilpotent groups such that each central extension of these groups is also residually nilpotent and the class of residually soluble groups such that each Abelian extension of these groups is residually soluble. Various examples of groups not belonging to these classes are constructed by homological methods and methods of the theory of modules over group rings. Several applications of the theory under consideration are presented and problems concerning the residual nilpotence of one-relator groups are considered.

  12. Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin

    International Nuclear Information System (INIS)

    Darquie, B.; Mejri, S.; Sow, P. L. T.; Lemarchand, C.; Triki, M.; Tokunaga, S. K.; Borde, C. J.; Chardonnet, C.; Daussy, C.

    2013-01-01

    Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 μm enables a determination of the Boltzmann constant k B . We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B , an exciting prospect considering the upcoming redefinition of the International System of Units. (authors)

  13. Quality characterization of reflectivity and radial velocity observed by Indian Doppler weather radars

    Science.gov (United States)

    Amarjyothi, Kasimahanthi; Dutta, Devajyoti; Devarajan, Preveen Kumar; George, John P.; Rajagopal, Ekkattil N.

    2017-07-01

    Static and dynamic quality index (QI) maps are generated as the base products of Doppler weather radar (DWR). The quality characterization of radar reflectivity and radial velocity in terms of their QI is presented for the operational DWRs in India. A static composite QI has been generated using the maximum method. These static maps enable the detection of a low QI region in advance for the Indian radars. The QI of reflectivity is above 0.5 in all regions except in the regions of blockage, high attenuation due to rain, and beam broadening, whereas the QI of radial velocity is good for values >0.8 except for the ambiguous region and the region affected by nonmeteorological echoes. This shall help in the quick preprocessing of radar observations, since the regions of low QI can be masked. A sample case of gridded radar rainfall is presented by employing the QI scheme.

  14. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  15. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  16. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  17. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  18. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    –0.97). Conclusion Color Doppler ultrasound is an effective noninvasive method for the initial diagnosis of impalpable testes and for planning its subsequent management. Keywords: color Doppler ultrasound, laparoscopy, nonpalpable testes ...

  19. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  20. Doppler Processing with Ultra-Wideband (UWB) Radar Revisited

    Science.gov (United States)

    2018-01-01

    Doppler processing in radar systems using ultra-wideband (UWB) waveforms. In light of more recent research in this area, we demonstrate that exact...Doppler frequency B – pulse bandwidth v – radial velocity of the target c – speed of light ρ – variable representing the Fourier pair of range (R...Typically, Doppler processing in radar consists of creating range-Doppler (R/D) maps—these are 2-D reflectivity maps of the scene under investigation by the

  1. Spectral Doppler of the hepatic veins in tricuspid valve disease.

    Science.gov (United States)

    Fadel, Bahaa M; Almulla, Khaled; Husain, Aysha; Dahdouh, Ziad; Di Salvo, Giovanni; Mohty, Dania

    2015-05-01

    Spectral Doppler recording of the hepatic veins (HV) provides a semiquantitative assessment of tricuspid regurgitation (TR) severity. It complements findings on two-dimensional echocardiography and color Doppler imaging and helps to discriminate between hemodynamically significant and nonsignificant degree of regurgitation. In this manuscript, we discuss the usefulness of the HV Doppler for the diagnosis of tricuspid valve (TV) disease and provide examples of the various spectral Doppler patterns that assist in the quantification of TR. © 2014, Wiley Periodicals, Inc.

  2. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  3. Quantum Theory of the Doppler Effect

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 10. Quantum Theory of the Doppler Effect. G S Ranganath. Classroom Volume 1 Issue 10 October 1996 pp 76-78. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/001/10/0076-0078 ...

  4. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  5. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  6. Doppler sonographic evaluation of venogenic extremity swellings ...

    African Journals Online (AJOL)

    Doppler ultrasound is very useful in the evaluation of extremity DVT. All clinically suspected cases should be evaluated with this modality due to limited sensitivity of clinical evaluation in the diagnosis of DVT. Further correlative studies in comparison to venography and hematologic indices are also recommended.

  7. An endoscopic Doppler probe: preliminary clinical evaluation

    NARCIS (Netherlands)

    Silverstein, F. E.; Deltenre, M.; Tytgat, G.; Martin, R. W.; Lesterhuis, W.; Burette, A.; Gilbert, D. A.

    1985-01-01

    A new pulsed Doppler catheter has been developed for use during gastrointestinal fiberendoscopy. Modern gastrointestinal endoscopy allows inspection of the wall of the entire esophagus, stomach, duodenum, and colon. Diagnosis is performed by inspecting the surface of the mucosa, biopsy, and

  8. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  9. Coherent Detection in Laser Doppler Velocimeters

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner

    1974-01-01

    , but intelligible particle picture of electromagnetic waves. The analysis is carried out with special emphasis on the heterodyning process in the laser Doppler velocimeter (LDV) because the main purpose of this article is to provide a better understanding of this instrument. An aid for this purpose...

  10. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  11. Use of the implantable Doppler in free tissue breast reconstruction.

    Science.gov (United States)

    Bedri, Mazen I; Chang, Bernard W

    2011-04-01

    In this article, the authors discuss the advances in monitoring free tissue transfers, with a focus on the implantable Doppler system. Authors address indications and techniques for implanting the Doppler system, in addition to presenting a framework to assess the reliability and potential benefits of the implantable Doppler device. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  13. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  14. On acceleration dependence of Doppler effect in light

    Indian Academy of Sciences (India)

    Using only the geometric relationships of suitable locations, we analyse Doppler effect in light to show how the acceleration of the source also contributes to the Doppler shift. We further propose that an experiment be performed using cyclotron-type devices to determine the acceleration dependence of the Doppler shift.

  15. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  16. Acute hemodialysis effects on doppler echocardiographic indices

    Directory of Open Access Journals (Sweden)

    Leila Abid

    2014-01-01

    Full Text Available Conventional echocardiographic (ECHO parameters of systolic and diastolic func-tion of the left ventricular (LV have been shown to be load dependent. However, the impact of pre-load reduction on tissue Doppler (TD parameters of LV function is incompletely understood. To evaluate the effect of a single hemodialysis (HD session on LV systolic and diastolic function using pulsed Doppler echocardiography and pulsed tissue Doppler imaging (TDI, we studied 81chronic HD patients (40 males; mean age 52.4 ± 16.4 years with these tools. ECHO parameters were obtained 30 min before and 30 min after HD. Fluid volume removed by HD was 1640 ± 730 cm [3] . HD led to reduction in LV end-diastolic volume (P <0.001, end-systolic volume (P <0.001, left atrium area (P <0.001, peak early (E-wave trans-mitral flow velocity (P <0.001, the ratio of early to late Doppler velocities of diastolic mitral inflow (P <0.001 and aortic time velocity integral (P <0.001. No significant change in peak S velocity of pulmonary vein flow after HD was noted. Early and late diastolic (E′ TDI velocities and the ratio of early to late TDI diastolic velocities (E′/A′ on the lateral side of the mitral annulus decreased signi-ficantly after HD (P = 0.013; P = 0.007 and P = 0.008, respectively. Velocity of flow progres-sion (Vp during diastole was not affected by pre-load reduction. Pulmonary artery systolic pressure and the diameter of the inferior vena cava decreased significantly (P <0.001 and P <0.001, respectively after HD. We conclude that most of the Doppler-derived indices of diastolic function are pre-load-dependent and velocity of flow progression was minimally affected by pre-load reduction in HD patients.

  17. Correlation function and electronic spectral line broadening in relativistic plasmas

    Directory of Open Access Journals (Sweden)

    Douis S.

    2013-01-01

    Full Text Available The electrons dynamics and the time autocorrelation function Cee(t for the total electric microfield of the electrons on positive charge impurity embedded in a plasma are considered when the relativistic dynamic of the electrons is taken into account. We have, at first, built the effective potential governing the electrons dynamics. This potential obeys a nonlinear integral equation that we have solved numerically. Regarding the electron broadening of the line in plasma, we have found that when the plasma parameters change, the amplitude of the collision operator changes in the same way as the time integral of Cee(t. The electron-impurity interaction is taken at first time as screened Deutsh interaction and at the second time as Kelbg interaction. Comparisons of all interesting quantities are made with respect to the previous interactions as well as between classical and relativistic dynamics of electrons.

  18. Leveraging biology interest to broaden participation in the geosciences

    Science.gov (United States)

    Perin, S.; Conner, L.; Oxtoby, L.

    2017-12-01

    It has been well documented that female participation in the geoscience workforce is low. By contrast, the biology workforce has largely reached gender parity. These trends are rooted in patterns of interest among youth. Specifically, girls tend to like biology and value social and societal connections to science (Brotman & Moore 2008). Our NSF-funded project, "BRIGHT Girls," offers two-week summer academies to high school-aged girls, in which the connections between the geosciences and biology are made explicit. We are conducting qualitative research to trace the girls' identity work during this intervention. Using team-based video interaction analysis, we are finding that the fabric of the academy allows girls to "try on" new possible selves in science. Our results imply that real-world, interdisciplinary programs that include opportunities for agency and authentic science practice may be a fruitful approach for broadening participation in the geosciences.

  19. Transverse momentum broadening in semi-inclusive DIS on nuclei

    International Nuclear Information System (INIS)

    Domdey, S.; Gruenewald, D.; Kopeliovich, B.Z.; Pirner, H.J.

    2009-01-01

    Using a three stage model of hadron formation we calculate the change of the transverse momentum distribution of hadrons produced in semi-inclusive deep inelastic scattering (SIDIS) on nuclei. In the first stage after its interaction with the virtual photon, the struck quark propagates quasi free in the nuclear environment undergoing multiple collisions with nucleons. During this stage it can acquire transverse momentum. In the second stage a prehadron is formed which has a very small elastic cross section with the nucleons. In the third stage the prehadron turns into a hadron. For HERMES energies, prehadron elastic scatterings contribute little to p perpendicular -broadening. The acquired extra Δp perpendicular 2 of hadrons can therefore be deduced entirely from the first stage of quasi free quark propagation with quark-nucleon collisions. We use this model to describe π-production on Ne, Kr, Xe and compare with the most recent HERMES data.

  20. Spectral broadening of planetary radar signals by the solar wind

    International Nuclear Information System (INIS)

    Harmon, J.K.; Coles, W.A.

    1983-01-01

    The microturbulence spectrum of the solar wind is estimated using the spectral broadening of planetary radar signals. Observations were made with the two radars (12.6 cm and 70 cm) at Arecibo Observatory during the 1979 and 1981 superior conjunctions of Venus. These observations, which span the solar distance range of 5.4 to 25.5 R/sub sun/, are the first of their type to be reported. The data are consistent with earlier observations where comparisons can be made. The flattening of the high-frequency portion of the spectrum near the Sun reported by Woo and Armstrong is confirmed. In one case clear evidence for an inner scale in the vicinity of 2 km is found. Two transients, 1979 August 15 and 1981 April 24-25, with rather different characteristics were observed

  1. Expansion and broadening of coronal loop transients: A theoretical explanation

    International Nuclear Information System (INIS)

    Mouschovias, T.C.; Poland, A.I.

    1978-01-01

    We explore the consequences of the assumption that a coronal loop transient (observed by the white-light coronagraph aboard Skylab) is a twisted rope of magnetic field lines expanding and broadening in the background coronal plasma and magnetic field. We show that the expansion (i.e., the outward motion of the loop top) can be accounted for by the azimuthal component of the field, B/sub az/; the observed broadening of the loop as it moves outward can be accounted for by the longitudinal component of the field, B/sub l/. In order to have a net outward force and at the same time avoid a classicial pinch (sausage) instability, the two components of the field must satisfy the inequality 1.41 B/sub l/>B/sub az/>B/sub l/.We predict that, as the loop rises, the width (h) of its top portion should vary proportionally with the distance (R) from the Sun's center. This is in good agreement with measurements that show hproportionalR/sup 0.8/. Our prediction, that the radius of curvature (R/sub c/) of the top portion of the loop should be proportional to R, differs from the measured variation R/sub c/proportionalR/sup 1.6/. The difference could be accounted for by a drag due to the background coronal field that flattens the loop's top. A statistical study that can test this possibility is suggested. We also calculate the magnetic field within the top section of the loop. It is approximately equal to 1 gauss at R=2 R/sub sun/ and varies somewhat more slowly than R -2 during expansion

  2. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  3. A doppler-based evaluation of peripheral lower limb arterial insufficiency in diabetes mellitus

    International Nuclear Information System (INIS)

    Shaheen, R.; Sohail, S.

    2010-01-01

    To determine the frequency, level and flow patterns of lower limb arterial insufficiency in diabetic patients on Doppler ultrasound study. Study Design: Cross-sectional study. Place and Duration of Study: Radiology Department, Civil Hospital, Karachi, from February 2007 to September 2008. Methodology: One hundred adult diabetic patients with suspected peripheral vascular insufficiency irrespective of gender were included. Demographic data, presenting complaints, treatment history, and level of HbA1c were recorded. Doppler evaluated arterial status and ankle brachial index (ABI) were recorded on proforma. Statistical analysis were done on SPSS version 12. Results: The mean HbA1c was 8.4 +- 1.4 gm/dl, a majority of 77% having a controlled level of < 10 mg/dl. Arterial insufficiency on Doppler ultrasound was documented in 62% (p=0.016) and the dorsalis paedis artery was the predominant site of stenosis (24%). Spectral broadening and biphasic flow were salient features. The mean value of resistive index in stenotic cases was 0.563 +- 0.16 with a mean velocity difference of 0.37 +- 0.29 m/s (p < 0.001) at the site of stenosis. Conclusion: Peripheral vascular insufficiency was a significant finding in patients having diabetes for an average of 9.8 years, even in the presence of controlled HbA1c. The dorsalis paedis was the commonest site of involvement. The insufficiency was moderate with a biphasic flow pattern in a majority of cases. Difference in resistive index and flow velocities at and above the site of stenosis provided an important clue to the diagnosis of level of stenosis that helps in planning limb salvage management. (author)

  4. The ν4 fundamental band of tetrafluoromethane: structure and broadening coefficients

    Science.gov (United States)

    Domanskaya, A. V.; Tonkov, Mikhail V.; Boissoles, J.

    2004-01-01

    Broadening coefficients for the ν4 fundamental band of carbon tetrafluoromethane, CF4, have been measured for the systems with argon, helium and nitrogen. Broadening coefficient behavior is similar to that previously reported for linear molecules: they coincide for P and R branches; the m-dependence in case of argon is sharper than that for helium. The broadening for nitrogen and helium are practically the same but the values for nitrogen are scattered around the general tendency. Q-branch broadening is also discussed. Our experimental data permitted us to evaluate the line intensity distribution and integrated intensity of the band.

  5. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  6. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  7. MEMS based Doppler velocity measurement system

    Science.gov (United States)

    Shin, Minchul

    The design, fabrication, modeling and characterization of a capacitive micromachined ultrasonic transducer (cMUT) based in-air Doppler velocity measurement system using a 1 cm2 planar array are described. Continuous wave operation in a narrowband was chosen in order to maximize range, as it allows for better rejection of broadband noise. The sensor array has a 160-185 kHz resonant frequency to achieve a 10 degree beamwidth. A model for the cMUT and the acoustic system which includes electrical, mechanical, and acoustic components is provided. Furthermore, characterization of the cMUT sensor with a variety of testing procedures is provided. Laser Doppler vibrometry (LDV), beampattern, reflection, and velocity testing characterize the performance of the sensors. The sensor is capable of measuring the velocity of a moving specular reflector with a resolution of 5 cm/s, an update rate of 0.016 second, and a range of 1.5 m.

  8. Color Doppler US of the penis

    International Nuclear Information System (INIS)

    Bertolotto, Michele

    2008-01-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  9. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  10. Predictive value of tissue Doppler imaging for left ventricular ejection fraction, remodelling, and infarct size after percutaneous coronary intervention for acute myocardial infarction

    NARCIS (Netherlands)

    van Melle, Joost P.; van der Vleuten, Pieter A.; Hummel, Yoran M.; Nijveldt, Robin; Tio, Rene A.; Voors, Adriaan A.; Zijlstra, Felix

    To investigate in ST-elevation myocardial infarction (STEMI) patients the value of tissue Doppler imaging (TDI) for an early estimation of the extent of myocardial salvage, left ventricular (LV) remodelling, and residual LV ejection fraction (LVEF). In 50 STEMI patients hospitalized for primary

  11. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  12. Colour Doppler ultrasound of the penis

    International Nuclear Information System (INIS)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S.

    2003-01-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis

  13. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    spectrum at a chosen resolution through application of digital filter bank . This spectrum is defined at a measurement time, or time of arrival for...calculated with a one-third-octave band filter bank employing Butterworth digital filters. To examine the results of the FOBS correction, Fig. 4...band energy obtained from fractional octave band digital filters generates a de-Dopplerized spectrum without complex resampling algorithms. An

  14. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  15. Broadening the Participation of Native Americans in Earth Science

    Science.gov (United States)

    Bueno Watts, Nievita

    Climate change is not a thing of the future. Indigenous people are being affected by climate changes now. Native American Earth scientists could help Native communities deal with both climate change and environmental pollution issues, but are noticeably lacking in Earth Science degree programs. The Earth Sciences produce the lowest percentage of minority scientists when compared with other science and engineering fields. Twenty semi-structured interviews were gathered from American Indian/ Alaska Native Earth Scientists and program directors who work directly with Native students to broaden participation in the field. Data was analyzed using qualitative methods and constant comparison analysis. Barriers Native students faced in this field are discussed, as well as supports which go the furthest in assisting achievement of higher education goals. Program directors give insight into building pathways and programs to encourage Native student participation and success in Earth Science degree programs. Factors which impede obtaining a college degree include financial barriers, pressures from familial obligations, and health issues. Factors which impede the decision to study Earth Science include unfamiliarity with geoscience as a field of study and career choice, the uninviting nature of Earth Science as a profession, and curriculum that is irrelevant to the practical needs of Native communities or courses which are inaccessible geographically. Factors which impede progress that are embedded in Earth Science programs include educational preparation, academic information and counseling and the prevalence of a Western scientific perspective to the exclusion of all other perspectives. Intradepartmental relationships also pose barriers to the success of some students, particularly those who are non-traditional students (53%) or women (80%). Factors which support degree completion include financial assistance, mentors and mentoring, and research experiences. Earth scientists

  16. Doppler sonographic findings in testicular microlithiasis

    Directory of Open Access Journals (Sweden)

    Selim Serter

    2008-08-01

    Full Text Available OBJECTIVE: The aim of this prospective study was to compare the resistive index (RI values, which is a parameter of testicular parenchymal perfusion, in testicular microlithiasis (TM cases and normal cases. MATERIALS AND METHODS: 2179 volunteers, all healthy men (17-42 years of age from the Annual Army Reserve Officer Training Corps training camp were included in the study. A screening scrotal ultrasound was performed and all men diagnosed with TM underwent a scrotal Doppler ultrasonography scan (US. US examinations were performed for subjects with TM and without TM as a control group and RI was determined. RESULTS: 53 men with TM were identified in the 2179 US. Spectral Doppler examination was applied to 50 randomly selected cases (100 testicles without TM and 92 testicles with TM, 39 cases (78 testicles with bilateral and 14 cases with unilateral involvement. However, 48 normal testicles (17 bilateral and 14 unilateral and 47 testicles with TM (15 bilateral and 17 unilateral, 10 of which were cases with bilateral TM where flow from the centripetal artery could be obtained and analyzed were included in the statistical analysis for resistive indices. There was no significant difference regarding the RI and spectral examinations between subjects with and without TM. An interesting finding was the twinkling artifact observed in three cases. CONCLUSION: Microliths did not alter the RI values and thus had no influence on testicular perfusion on Doppler US examination.

  17. Doppler Lidar for Wind Measurements on Venus

    Science.gov (United States)

    Singh, Upendra N.; Emmitt, George D.; Yu, Jirong; Kavaya, Michael J.

    2010-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

  18. Magnetic Field Measurements In Magnetized Plasmas Using Zeeman Broadening Diagnostics

    Science.gov (United States)

    Haque, Showera; Wallace, Matthew; Presura, Radu; Neill, Paul

    2017-10-01

    The Zeeman effect has been used to measure the magnetic field in high energy density plasmas. This method is limited when plasma conditions are such that the line broadening due to the high plasma density and temperature surpasses the Zeeman splitting. We have measured magnetic fields in magnetized laser plasmas under conditions where the Zeeman splitting was not spectrally resolved. The magnetic field strength was determined from the difference in widths of two doublet components, using an idea proposed by Tessarin et al. (2011). Time-gated spectra with one-dimensional space-resolution were obtained at the Nevada Terawatt Facility for laser plasmas created by 20 J, 1 ns Leopard laser pulses, and expanding in the azimuthal magnetic field produced by the 0.6 MA Zebra pulsed power generator. We explore the response of the Al III 4s 2S1/2 - 4p 2P1 / 2 , 3 / 2 doublet components to the external magnetic field spatially along the plasma. Radial magnetic field and electron density profiles were measured within the plasma plume. This work was supported by the DOE/OFES Grant DE-SC0008829 and DOE/NNSA contract DE-FC52-06NA27616.

  19. On broadened definitions of instability for stars in thermal imbalance

    International Nuclear Information System (INIS)

    Simon, N.R.

    1977-01-01

    The classical theory of stability of dynamical systems is employed to demonstrate that traditional definitions of pulsational instability cannot be directly applied to stars in thermal imbalance. In particular, it is shown that, for the case of thermal imbalance, pulsational displacements and pulsational velocities have separate and distinct e-folding times. This being true, a broadened set of definitions becomes necessary, and such a set is formulated again with reference to the classical theory. In accordance with the new definitions, it is argued that the development of observable pulsations requires as a necessary condition infinitesimal instability of both absolute displacement and velocity. If either one is unstable without the other, this constitutes a class of (probably) non-pulsational instability, not previously treated in the astrophysical literature. Finally, it is shown that the stability of stars in thermal imbalance may be evaluated according to the present definitions by employing either of two existing theories - the energy approach due to Demaret (1974; 1975; 1976) or the small perturbation technique of Cox et al. (1973). (Auth.)

  20. Broadening Participation: Mentoring Community College Students in a Geoscience REU

    Science.gov (United States)

    Smith, M.; Osborn, J.

    2015-12-01

    Increasingly, REUs are recruiting from community colleges as a means of broadening participation of underrepresented minorities, women, and low-income students in STEM. As inclusion of community college students becomes normalized, defining the role of science faculty and preparing them to serve as mentors to community college students is a key component of well-designed programs. This session will present empirical research regarding faculty mentoring in the first two years of an NSF-REU grant to support community college students in a university's earth and environmental science labs. Given the documented benefits of undergraduate research on students' integration into the scientific community and their career trajectory in STEM, the focus of the investigation has been on the processes and impact of mentoring community college STEM researchers at a university serving a more traditionally privileged population; the degree to which the mentoring relationships have addressed community college students needs including their emotional, cultural and resource needs; and gaps in mentor training and the mentoring relationship identified by mentors and students.

  1. Finding probability distributions for electric field gradient components with inhomogeneous broadening in perturbed angular correlation spectroscopy

    Science.gov (United States)

    Park, Tyler; Adams, Mike; Bunker, Austin; Hodges, Jeffery; Stufflebeam, Michael; Evenson, William; Matheson, Phil; Zacate, Matthew

    2009-10-01

    Materials contain defects, which affect crystal properties such as damping of the correlation signal,G2(t), in time and broadening of the frequency spectrum in perturbed angular correlation (PAC) experiments. We attribute this inhomogeneous broadening (IHB) to the random static defects that produce a distribution of electric field gradients (EFGs). Our goal is to find a relationship between the amount of broadening and the concentration of defects. After simulating the EFGs from random configurations of defects, we map our results from the Vzz-Vxx plane to a coordinate system optimized for the EFG distribution through a Czjzek transformation, followed by a conformal mapping. From histograms in this space, we can define probability distribution functions with parameters that vary according to defect concentration. This allows us to calculate the broadened G2(t) spectrum for any concentration, and, in reverse, identify concentrations given a broadened G2(t) spectrum.

  2. Line broadening mechanisms of the orth-H2 pair spectrum

    International Nuclear Information System (INIS)

    Statt, B.W.; Hardy, W.N.

    1980-01-01

    Three broadening mechanisms for the ortho pair spectrum in solid hydrogen are investigated. First, theoretical predictions of the phonon induced lifetime broadening are presented. Next a theory is developed which gives the inhomogeneous broadening due to the presence of ortho molecules surrounding the pairs. An unexpected result is that certain lines remain unbroadened, at least to within the approximation made. Strain effects due to isotopic mass defect impurities are also considered. These predictions are then compared with experimental results. No temperature dependence of the lineshapes is observed, setting an upper limit on the phonon broadening contribution to the linewidth. This limit is an order of magnitude lower than the theory predicts. The predictions of the ortho broadening theory, on the other hand, are in good agreement with experiment. Samples doped with isotopic impurities are also investigated. (auth)

  3. Spectral broadening in narrow linewidth, continuous-wave high power fiber amplifiers

    Science.gov (United States)

    Feng, Yujun; Wang, Xiaojun; Ke, Weiwei; Sun, Yinhong; Zhang, Kai; Ma, Yi; Li, Tenglong; Wang, Yanshan; Wu, Juan

    2017-11-01

    We present an investigation on the spectrum broadening in continuous-wave, sub-nanometer linewidth high power fiber amplifiers caused by the multiple four-wave mixing (FWM) process. The spectrum broadening employing two different types of narrow linewidth seeds, including the multi-longitudinal-mode seed and the broadened single frequency seed generated by high speed phase modulation, is studied. It is shown both theoretically and experimentally that the multi-longitudinal-mode seed experiences serious spectrum broadening induced by the FWM among various longitudinal modes, while the modulated seed can maintain the spectrum profile during the amplifying process even with some noise fluctuation. The different broadening results are mainly caused by the random phase distribution of the multiple waves. It is further explained by an exact solution of the degenerate FWM with three waves. The theoretical predictions on the spectrum and power dependence of the output laser linewidth are in quantitative agreement with the experimental results up to kilowatt.

  4. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  5. Baroreflex regulation measurement using a noninvasive laser Doppler method

    Science.gov (United States)

    Hast, Jukka T.; Myllylae, Risto A.; Sorvoja, Hannu; Nissilae, Seppo M.

    2001-05-01

    In this study, a noninvasive laser Doppler measurement method based on the self-mixing effect of a diode laser was used to measure baroreflex regulation, which is manifest in the blood pressure signal as a 0.1 Hz sinusoidal variation. The laser Doppler measurement system was used to measure the movement of the right radial artery of ten volunteers. Variation in blood pressure caused by the baroreflex affects the elastic properties of the arterial wall. When diastolic blood pressure increases, the elasticity of the arterial wall decreases, causing the wall to lose some of its movability. This decreased elasticity reveals itself in the Doppler signal such that when the blood pressure increases, the Doppler frequency decreases and vice versa. The results show, that the laser Doppler method can be used to measure baroreflex regulation. Finally, baroreflex regulation in the Doppler signal is approximately in the inverse phase with respect to variation in diastolic blood pressure.

  6. Broadening of electron beams through a single glass macrocapillary

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Dassanayake, B.S.; Tanis, J.A.

    2011-01-01

    Complete text of publication follows. The interaction of charged particles with insulating capillaries has motivated the development of nanotechnology. The interaction of slow (few keV) highly charged ions (HCI) with several kinds of insulating capillaries has been studied recently, experimentally and theoretically. These studies have shown that a considerable fraction of the ions are transmitted through the nanocapillary without close collisions with the inner wall. Moreover, the transmission of slow negative ions through insulating nanocapillary foils shows that these ions can also be guided through nanocapillaries. Studies also include faster electrons transmitting through Al 2 O 3 nanocapillaries, polyethylene terephthalate (PET) nanocapillaries, and a single glass macrocapillary. Results for electrons (200 to 350 eV) through highly ordered insulating Al 2 O 3 nanocapillaries with a large aspect ratio of 100 show evidence of guiding. Even faster electrons (500 and 1000 eV) show guiding through PET capillaries with considerable energy loss increasing with tilt angle due to inelastic scattering with the inner surface of the capillary. For the single glass macrocapillary, the transmitted electrons are found to lose energy for the same reason. Guiding is also achieved with the single glass macrocapillary for slow highly-charged ions, but no energy loss is seen. Single glass capillaries have been applied with the intention of producing submicrometer sized beams that can be used for surface modification or to selectively damage the structure of biological cells. We investigated the broadening of electron beams when traveling through an insulating single cylindrically-shaped glass capillary of macroscopic dimensions. Glass capillary samples (diameters d = 0.18 and 0.23 mm and lengths l = 14.4 and 16.8 mm) made of Borosilicate glass were subjected to bombardment by ∼500 eV electrons. Defocusing effects have also been observed in most of the electron transmission

  7. Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar.

    Science.gov (United States)

    Xia, Haiyun; Dou, Xiankang; Shangguan, Mingjia; Zhao, Ruocan; Sun, Dongsong; Wang, Chong; Qiu, Jiawei; Shu, Zhifeng; Xue, Xianghui; Han, Yuli; Han, Yan

    2014-09-08

    Temperature detection remains challenging in the low stratosphere, where the Rayleigh integration lidar is perturbed by aerosol contamination and ozone absorption while the rotational Raman lidar is suffered from its low scattering cross section. To correct the impacts of temperature on the Rayleigh Doppler lidar, a high spectral resolution lidar (HSRL) based on cavity scanning Fabry-Perot Interferometer (FPI) is developed. By considering the effect of the laser spectral width, Doppler broadening of the molecular backscatter, divergence of the light beam and mirror defects of the FPI, a well-behaved transmission function is proved to show the principle of HSRL in detail. Analysis of the statistical error of the HSRL is carried out in the data processing. A temperature lidar using both HSRL and Rayleigh integration techniques is incorporated into the Rayleigh Doppler wind lidar. Simultaneous wind and temperature detection is carried out based on the combined system at Delhi (37.371°N, 97.374°E; 2850 m above the sea level) in Qinghai province, China. Lower Stratosphere temperature has been measured using HSRL between 18 and 50 km with temporal resolution of 2000 seconds. The statistical error of the derived temperatures is between 0.2 and 9.2 K. The temperature profile retrieved from the HSRL and wind profile from the Rayleigh Doppler lidar show good agreement with the radiosonde data. Specifically, the max temperature deviation between the HSRL and radiosonde is 4.7 K from 18 km to 36 km, and it is 2.7 K between the HSRL and Rayleigh integration lidar from 27 km to 34 km.

  8. Some Strategies From SOARS for Broadening Participation in the Geosciences

    Science.gov (United States)

    Haacker-Santos, R.; Pandya, R.; Calhoun, A.

    2006-12-01

    The mission of SOARS® is to broaden participation in the geosciences by increasing the number of Black or African-American, American Indian or Alaska Native, Hispanic or Latino, female, and first-generation college students who enroll and succeed in graduate school in the atmospheric and related sciences. This mission contributes to national goals of developing a diverse, internationally competitive, and globally engaged workforce of scientists and engineers. SOARS is a multiyear undergraduate-to-graduate bridge program that uses three strategies: a strong learning community, a multidimensional mentoring program, and experience in research. Our presentation will describe SOARS' strategies in more detail, with an eye toward how such strategies might be adapted for other programs. To do this, we will draw upon recent research that documents how these strategies can be successfully implemented, including: - A survey of over 124 higher-education based STEM programs - A workshop report from the American Chemical Society emphasizing cooperation between industry and academia - An independent ethnographic study of the Significant Opportunities in Atmospheric and Related Science (SOARS®) program, administered by the University Corporation for Atmospheric Research (UCAR) In the 11 years since SOARS' founding, 104 students have participated in the program. Of those participants, 16 are still enrolled as undergraduates, and 60 have gone on to purse graduate school in STEM. Overall, this represents a success rate 91%. Of the 35 SOARS participants who have entered the workforce, 26 are in STEM related disciplines. Four SOARS participants have already earned their PhD, and additional 17 are in PhD programs. Seventeen protégés have earned Master's and entered the workforce, and 17 more protégés are enrolled in Master's programs.

  9. How Might Industry Governance Be Broadened To Include Nonproliferation

    International Nuclear Information System (INIS)

    Hund, Gretchen; Seward, Amy M.

    2009-01-01

    Broadening industry governance to support nonproliferation could provide significant new leverage in preventing the spread/diversion of nuclear, radiological, or dual-use material or technology that could be used in making a nuclear or radiological weapon. Industry is defined broadly to include (1) the nuclear industry, (2) dual-use industries, and (3) radioactive source manufacturers and selected radioactive source-user industries worldwide. This paper describes how industry can be an important first line of defense in detecting and thwarting proliferation, such as an illicit trade network or an insider theft case, by complementing and strengthening existing governmental efforts. For example, the dual-use industry can play a critical role by providing export, import, or security control information that would allow a government or the International Atomic Energy Agency (IAEA) to integrate this information with safeguards, export, import, and physical protection information it has to create a more complete picture of the potential for proliferation. Because industry is closest to users of the goods and technology that could be illicitly diverted throughout the supply chain, industry information can potentially be more timely and accurate than other sources of information. Industry is in an ideal position to help ensure that such illicit activities are detected. This role could be performed more effectively if companies worked together within a particular industry to promote nonproliferation by implementing an industry-wide self-regulation program. Performance measures could be used to ensure their materials and technologies are secure throughout the supply chain and that customers are legitimately using and/or maintaining oversight of these items. Nonproliferation is the overarching driver that industry needs to consider in adopting and implementing a self-regulation approach. A few foreign companies have begun such an approach to date; it is believed that

  10. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  11. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  12. EUV Doppler Imaging for CubeSat Platforms Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Mature the design and fabricate the Flare Initiation Doppler Imager (FIDI) instrument to demonstrate low-spacecraft-resource EUV technology (most notably,...

  13. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  14. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Zanier Francesca

    2007-01-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  15. [Color Doppler sonography of focal abdominal lesions].

    Science.gov (United States)

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  16. Mobile fiber-optic laser Doppler anemometer.

    Science.gov (United States)

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  17. Time Sequence Spectroscopy of AW UMa. The 518 nm Mg i Triplet Region Analyzed With Broadening Functions

    Science.gov (United States)

    Rucinski, Slavek M.

    2015-02-01

    High-resolution spectroscopic observations of AW UMa, obtained on three consecutive nights with a median time resolution of 2.1 minutes, have been analyzed using the broadening function method in the spectral window of 22.75 nm around the 518 nm Mg i triplet region. Doppler images of the system reveal the presence of vigorous mass motions within the binary system; their presence puts into question the solid-body rotation assumption of the contact binary model. AW UMa appears to be a very tight, semi-detached binary; the mass transfer takes place from the more massive to the less massive component. The primary, a fast-rotating star with Vsin i=181.4+/- 2.5 km s-1, is covered with inhomogeneities: very slowly drifting spots and a dense network of ripples more closely participating in its rotation. The spectral lines of the primary show an additional broadening component (called the “pedestal”) that originates either in the equatorial regions, which rotate faster than the rest of the star by about 50 km s-1, or in an external disk-like structure. The secondary component appears to be smaller than predicted by the contact model. The radial velocity field around the secondary is dominated by accretion of matter transferred from (and possibly partly returned to) the primary component. The parameters of the binary are Asin i=2.73+/- 0.11 {{R}⊙ } and {{M}1}{{sin }3}i=1.29+/- 0.15 {{M}⊙ }, {{M}2}{{sin }3}i=0.128+/- 0.016 {{M}⊙ }. The mass ratio, {{q}sp}={{M}2}/{{M}1}=0.099+/- 0.003, while still the most uncertain among the spectroscopic elements, is substantially different from the previous numerous and mutually consistent photometric investigations which were based on the contact model. It should be studied why photometry and spectroscopy give such discrepant results and whether AW UMa is an unusual object or if only very high-quality spectroscopy can reveal the true nature of W UMa-type binaries. Based on observations obtained at the Canada

  18. Time sequence spectroscopy of AW UMa. The 518 nm Mg I triplet region analyzed with broadening functions

    International Nuclear Information System (INIS)

    Rucinski, Slavek M.

    2015-01-01

    High-resolution spectroscopic observations of AW UMa, obtained on three consecutive nights with a median time resolution of 2.1 minutes, have been analyzed using the broadening function method in the spectral window of 22.75 nm around the 518 nm Mg i triplet region. Doppler images of the system reveal the presence of vigorous mass motions within the binary system; their presence puts into question the solid-body rotation assumption of the contact binary model. AW UMa appears to be a very tight, semi-detached binary; the mass transfer takes place from the more massive to the less massive component. The primary, a fast-rotating star with Vsini=181.4±2.5 km s −1 , is covered with inhomogeneities: very slowly drifting spots and a dense network of ripples more closely participating in its rotation. The spectral lines of the primary show an additional broadening component (called the “pedestal”) that originates either in the equatorial regions, which rotate faster than the rest of the star by about 50 km s −1 , or in an external disk-like structure. The secondary component appears to be smaller than predicted by the contact model. The radial velocity field around the secondary is dominated by accretion of matter transferred from (and possibly partly returned to) the primary component. The parameters of the binary are Asini=2.73±0.11 R ⊙ and M 1 sin 3 i=1.29±0.15 M ⊙ , M 2 sin 3 i=0.128±0.016 M ⊙ . The mass ratio, q sp =M 2 /M 1 =0.099±0.003, while still the most uncertain among the spectroscopic elements, is substantially different from the previous numerous and mutually consistent photometric investigations which were based on the contact model. It should be studied why photometry and spectroscopy give such discrepant results and whether AW UMa is an unusual object or if only very high-quality spectroscopy can reveal the true nature of W UMa-type binaries.

  19. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  20. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    OpenAIRE

    Márcio Martins Machado; Ana Cláudia Ferreira Rosa; Paulo Herman; Nestor de Barros; Orlando Milhomem da Mota; Letícia Martins Azeredo; Osterno Queiroz da Silva; Jales Benevides Santana Filho; Paulo Moacir O. Campoli; Paulo Adriano Q. Barreto; Patrícia Medeiros Milhomem; Leonardo Medeiros Milhomem; Murilo Tavares Daher; Renato Tavares Daher; Luciana Mendes de Oliveira Cerri

    2004-01-01

    Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler"). Fazem, também, referência a novas modalidades...

  1. S-Band Doppler Wave Radar System

    Directory of Open Access Journals (Sweden)

    Zezong Chen

    2017-12-01

    Full Text Available In this paper, a novel shore-based S-band microwave Doppler coherent wave radar (Microwave Ocean Remote SEnsor (MORSE is designed to improve wave measurements. Marine radars, which operate in the X band, have been widely used for ocean monitoring because of their low cost, small size and flexibility. However, because of the non-coherent measurements and strong absorption of X-band radio waves by rain, these radar systems suffer considerable performance loss in moist weather. Furthermore, frequent calibrations to modify the modulation transfer function are required. To overcome these shortcomings, MORSE, which operates in the S band, was developed by Wuhan University. Because of the coherent measurements of this sensor, it is able to measure the radial velocity of water particles via the Doppler effect. Then the relation between the velocity spectrum and wave height spectrum can be used to obtain the wave height spectra. Finally, wave parameters are estimated from the wave height spectra by the spectrum moment method. Comparisons between MORSE and Waverider MKIII are conducted in this study, and the results, including the non-directional wave height spectra, significant wave height and average wave period, are calculated and displayed. The correlation coefficient of the significant wave height is larger than 0.9, whereas that of the average wave period is approximately 0.4, demonstrating the effectiveness of MORSE for the continuous monitoring of ocean areas with high accuracy.

  2. Fusion of Telescopic and Doppler Radar Data

    Science.gov (United States)

    Navara, M.; Matousek, M.; Drbohlav, O.

    2014-09-01

    We study the possibilities of observations of satellites at circular LEO orbits simultaneously by a telescope and a bistatic continuous-wave Doppler radar. Telescopic images allow for trajectory determination except for its distance (and hence height). Assuming a circular orbit, the height can be computed from the angular speed, but this is often impossible for LEO objects which do not remain in the field of view during the whole exposure time. To restore the missing information, we use Doppler radar data from a radio astronomy network, originally designed for detection of meteors. Using simulated perturbations of real radar data we studied their influence on the estimates of (i) permanent parameters of trajectory (orbital elements), (ii) instantaneous parameters of trajectory, (iii) distance and height estimates if the other parameters are given by the telescopic data. We derived recommendations for the optimal positions of the transmitter and receivers leading to the best resolution. We also discuss possible ways of improvement of this technique. Fusion results are shown on a suite of several matched radar and telescopic satellite fly-over data.

  3. The effect of broadened linewidth induced by dispersion on the performance of resonant optical gyroscope

    Science.gov (United States)

    Zhang, Hao; Li, Wenxiu; Han, Peng; Chang, Xiaoyang; Liu, Jiaming; Lin, Jian; Xue, Xia; Zhu, Fang; Yang, Yang; Liu, Xiaojing; Zhang, Xiaofu; Huang, Anping; Xiao, Zhisong; Fang, Jiancheng

    2018-01-01

    Anomalous dispersion enhancement physical mechanism for Sagnac effect is described by special relativity derivation, and three kinds of definitions of minimum detectable angular rate of resonance optical gyroscope (ROG) are compared and the relations among them are investigated. The effect of linewidth broadening induced by anomalous dispersion on the sensitivity of ROG is discussed in this paper. Material dispersion-broadened resonance linewidth deteriorates the performance of a passive ROG and dispersion enhancement effect, while the sensitivity of a structural dispersion ROG is enhanced by two orders of magnitude even considering the dispersion-broadened resonance linewidth.

  4. A Rayleigh Doppler Frequency Estimator Derived from Maximum Likelihood Theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiene; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers.The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminalmovement can optimize cell capac...

  5. On acceleration dependence of Doppler effect in light

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 81; Issue 3. On acceleration dependence of ... Using only the geometric relationships of suitable locations, we analyse Doppler effect in light to show how the acceleration of the source also contributes to the Doppler shift. We further propose that an experiment be ...

  6. Normal Foetal Middle Cerebral Arteries Doppler Velocimetry; Study ...

    African Journals Online (AJOL)

    Doppler assessment of the middle cerebral artery (MCA) is one method of evaluating foetus before delivery and can determine foetuses at risk in high risk pregnancies. This study was done to determine the normal reference values of foetal middle cerebral artery Doppler indices in our population. One hundred and forty ...

  7. Umbilical artery doppler velocimetry study on prediction of adverse ...

    African Journals Online (AJOL)

    Background: Doppler velocimetry studies of pregnant women with diabetes mellitus can predict adverse pregnancy outcomes. Objective: To identify pregnant women with diabetes mellitus for second trimester umbilical artery Doppler velocimetry to predict adverse pregnancy outcomes. Methods: It was a prospective study ...

  8. Detection and visualization to Doppler sensitive sonar pulses

    NARCIS (Netherlands)

    Bertrand, D.B.; IJsselmuide, S.P. van; Beerens, S.P.

    2006-01-01

    In anti-submarine warfare, the use of Doppler sensitive sonar pulses is common practice. In particular, the wideband Doppler sensitive PTFM pulse (Pulse Train Frequency Modulation) is a powerful tool for detection in reverberation limited conditions. Nevertheless, this pulse is not operationally

  9. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    Abstract. Relativistic beaming effect is important for blazars. In a very recent work, γ-ray Doppler factors were calculated for a sample of Fermi blazars (Fan et al. 2013). In this work, we investigated the correlation between the Doppler factor and the effective spectral index, αOX, and found an anticorrelation between them.

  10. Optical Doppler tomography based on a field programmable gate array

    DEFF Research Database (Denmark)

    Larsen, Henning Engelbrecht; Nilsson, Ronnie Thorup; Thrane, Lars

    2008-01-01

    We report the design of and results obtained by using a field programmable gate array (FPGA) to digitally process optical Doppler tomography signals. The processor fits into the analog signal path in an existing optical coherence tomography setup. We demonstrate both Doppler frequency and envelope...

  11. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guid...

  12. Doppler weather radar with predictive wind shear detection capabilities

    Science.gov (United States)

    Kuntman, Daryal

    1991-01-01

    The status of Bendix research on Doppler weather radar with predictive wind shear detection capability is given in viewgraph form. Information is given on the RDR-4A, a fully coherent, solid state transmitter having Doppler turbulence capability. Frequency generation data, plans, modifications, system characteristics and certification requirements are covered.

  13. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ER-2 Doppler radar (EDOP) is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The instrument has two fixed antennas, one pointing at nadir and the...

  14. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were us...

  15. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  16. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  17. Experience in scrotal doppler ultrasound in a Nigerian tertiary hospital

    African Journals Online (AJOL)

    Background: Scrotal diseases can be diagnosed with clinical examination or radiological imaging. The use of ultrasound with Doppler application has several advantages in the evaluation of this sensitive and private organ. Objectives: To document the pattern of Doppler ultrasound findings in patients presenting with ...

  18. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Doppler redshifts of a sample of Mg II associated absorbers of SDSS DR7 quasars are analysed. We find that there might be three Gaussian components in the distribution of the Doppler redshift. The first Gaussian component, with the peak being located at Dopp = -0.0074, probably arises from absorbers ...

  19. Methodology for obtaining wind gusts using Doppler lidar

    DEFF Research Database (Denmark)

    Suomi, Irene; Gryning, Sven-Erik; O'Connor, Ewan J.

    2017-01-01

    A new methodology is proposed for scaling Doppler lidar observations of wind gusts to make them comparable with those observed at a meteorological mast. Doppler lidars can then be used to measure wind gusts in regions and heights where traditional meteorological mast measurements are not availabl...

  20. A Rayleigh Doppler frequency estimator derived from maximum likelihood theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiéne; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers. The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminal movement can optimize cell cap...

  1. Trace isotope analysis using resonance ionization mass spectrometry based on isotope selection with doppler shift of laser ablated atoms

    International Nuclear Information System (INIS)

    Higuchi, Yuki; Watanabe, Kenichi; Kawarabayashi, Jun; Iguchi, Tetsuo

    2005-01-01

    We have proposed a novel isotope selective Resonance Ionization Mass Spectroscopy (RIMS) concept, which can avoid the Doppler broadening on solid sample direct measurement based on laser ablation technique. We have succeeded in experimentally demonstrating the principle of our RIMS concept. Through comparison between the simulated and experimental results, we have validated the simulation model. It would be concluded from these results that we could achieve the isotope selectivity defined as the ratio of 41 Ca to 40 Ca sensitivity to be 4.5x10 10 by adopting the multi-step excitation scheme in the present method. As future works, we will try to experimentally perform the multi-step excitation scheme and improve the detection efficiency by modifying the ion extraction configuration. (author)

  2. Analysis of Doppler effect with JAERI-Fast set

    International Nuclear Information System (INIS)

    Takano, Hideki; Matsui, Yasushi.

    1977-07-01

    Temperature dependence of group cross sections in the JAERI-Fast set versions I, IR, II and IIR has been tested from the analysis of Doppler experiments performed with two different methods. One is Doppler reactivity measurement for the whole core of SEFOR assembly, and the other sample Doppler reactivity measurement for natural UO 2 in FCA assemblies V-1, V-2, VI-1 and VI-2, ZPR-6-7, ZPR-3-47, and ZPPR-2 and 3. Doppler effects were calculated with one- and two-dimensional diffusion 1-st order perturbation code DOPP2D. The results calculated with the JAERI-Fast set versions II and IIR are in good agreement with the experimental ones. In these calculation, resonance heterogeneity effect, stainless-stell buffer effect and plate heterogeneity effect are considered, and these effects contribute significantly to Doppler effect. (auth.)

  3. Simulated models of inhomogeneous broadening in perturbed angular correlation spectroscopy (PAC)

    Science.gov (United States)

    Stufflebeam, Michael A.; Hodges, Jeffery A.; Evenson, William E.; Matheson, P.; Zacate, M. O.

    2007-10-01

    All real crystals have defects: missing atoms (vacancies), impurities, atoms out of place, etc. In perturbed angular correlation (PAC), these defects produce damping of the correlation signal in time and broadening of the frequency spectrum. This broadening is termed ``inhomogeneous broadening'' since it is due to the inhomogeneities (i.e. defects) in the crystal. We have simulated PAC spectra for various concentrations (0.1% to 5%) of distant randomly distributed defects plus a near-neighbor vacancy in simple cubic and face-centered cubic crystal structures. For every particular set of defects, the randomly distributed defects and the near-neighbor vacancy together produce a net electric field gradient (EFG), from which we obtain the PAC spectrum. We fit average PAC spectra to study the effects of defect concentration and crystal structure on inhomogeneous broadening as an aid to analyzing experimental data.

  4. Oxygen, nitrogen and air broadening of HCN spectral lines at terahertz frequencies

    International Nuclear Information System (INIS)

    Yang Chun; Buldyreva, Jeanna; Gordon, Iouli E.; Rohart, Francois; Cuisset, Arnaud; Mouret, Gael; Bocquet, Robin; Hindle, Francis

    2008-01-01

    The room-temperature nitrogen- and oxygen-broadening coefficients of hydrogen cyanide spectral lines have been measured in the 0.5-3 THz (17-100 cm -1 ) frequency range (purely rotational transitions with 5≤J≤36) by a continuous-wave terahertz spectrometer based on a photomixing source. An improved version of the Robert and Bonamy semiclassical formalism has been used to calculate the oxygen-broadening coefficients and resulted in a good agreement with these measurements. The nitrogen and oxygen data are combined to provide the air-broadening coefficients as used by the HITRAN database. A significant difference is observed between the measured and tabulated values for transitions with high values of the rotational quantum number. A new polynomial representation is suggested for inclusion in HITRAN. A similar polynomial expression has been derived for the nitrogen broadening to aid the studies of Titan's atmosphere

  5. Oxygen, nitrogen and air broadening of HCN spectral lines at terahertz frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Yang Chun [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France); Buldyreva, Jeanna [Institut UTINAM, UMR CNRS 6213, Universite de Franche-Comte, 16, Route de Gray, 25030 Besancon Cedex (France); Gordon, Iouli E. [Harvard-Smithsonian Center for Astrophysics, Atomic and Molecular Physics Division, 60 Garden Street, Cambridge, MA 02138-1516 (United States); Rohart, Francois [Laboratoire de Physique des Lasers, Atomes et Molecules, UMR CNRS 8523, Batiment P5-135, Universite de Lille 1, 59655 Villeneuve d' Ascq Cedex (France); Cuisset, Arnaud; Mouret, Gael; Bocquet, Robin [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France); Hindle, Francis [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France)], E-mail: francis.hindle@univ-littoral.fr

    2008-11-15

    The room-temperature nitrogen- and oxygen-broadening coefficients of hydrogen cyanide spectral lines have been measured in the 0.5-3 THz (17-100 cm{sup -1}) frequency range (purely rotational transitions with 5{<=}J{<=}36) by a continuous-wave terahertz spectrometer based on a photomixing source. An improved version of the Robert and Bonamy semiclassical formalism has been used to calculate the oxygen-broadening coefficients and resulted in a good agreement with these measurements. The nitrogen and oxygen data are combined to provide the air-broadening coefficients as used by the HITRAN database. A significant difference is observed between the measured and tabulated values for transitions with high values of the rotational quantum number. A new polynomial representation is suggested for inclusion in HITRAN. A similar polynomial expression has been derived for the nitrogen broadening to aid the studies of Titan's atmosphere.

  6. Extrapolation method of the elimination of instrumental broadening of diffraction lines

    Czech Academy of Sciences Publication Activity Database

    Čerňanský, Marian

    2000-01-01

    Roč. 7, č. 1 (2000), s. 3-5 ISSN 1211-5894 Institutional research plan: CEZ:AV0Z1010914 Keywords : XRD line brodening * instrumental broadening * powder diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism

  7. Disorder-induced resonance shifts and mode edge broadening in photonic crystal waveguides

    DEFF Research Database (Denmark)

    Mann, N.; Javadi, Alisa; Garcia-Fernandez, Pedro David

    2014-01-01

    We present theory and measurements for systematically disordered slow-light photonic crystal waveguides and find a pronounced disorder-induced blueshift and broadening of the photon density of states....

  8. Smile to see the forest: Facially expressed positive emotions broaden cognition

    Science.gov (United States)

    Johnson, Kareem J.; Waugh, Christian E.; Fredrickson, Barbara L.

    2011-01-01

    The broaden hypothesis, part of Fredrickson’s (1998, 2001) broaden-and-build theory, proposes that positive emotions lead to broadened cognitive states. Here, we present evidence that cognitive broadening can be produced by frequent facial expressions of positive emotion. Additionally, we present a novel method of using facial electromyography (EMG) to discriminate between Duchenne (genuine) and non-Duchenne (non-genuine) smiles. Across experiments, Duchenne smiles occurred more frequently during positive emotion inductions than neutral or negative inductions. Across experiments, Duchenne smiles correlated with self-reports of specific positive emotions. In Experiment 1, high frequencies of Duchenne smiles predicted increased attentional breadth on a global–local visual processing task. In Experiment 2, high frequencies of Duchenne smiles predicted increased attentional flexibility on a covert attentional orienting task. These data underscore the value of using multiple methods to measure emotional experience in studies of emotion and cognition. PMID:23275681

  9. Angular Broadening of Intraday Variable AGNs II. Interstellar and Intergalactic Scattering

    National Research Council Canada - National Science Library

    Lazio, T. J; Ojha, Roopesh; Fey, Alan L; Kedziora-Chudczer, Lucyna; Cordes, James M; Jauncey, David L; Lovell, James E

    2008-01-01

    ... (interstellar scintillation), while the other 25% do not show intraday variability. We find that interstellar scattering is measurable for most of these AGNs, and the typical broadening diameter is 2 mas at 1 GHz...

  10. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  11. Stark broadening of the Hα line of hydrogen at low densities: quantal and semiclassical results

    International Nuclear Information System (INIS)

    Stehle, C.; Feautrier, N.

    1984-01-01

    Stark profiles of the Hα lines of hydrogen are computed at low densities in the 'impact' theory. By a comparison with quantal results, it is shown that a simple semiclassical perturbational approach with appropriate cutoffs is sufficient to give accurate profiles in the line centre. Neglecting the natural broadening and the fine-structure effects, the authors prove that the electronic broadening is negligible and that the profile has a Lorentzian shape. An analytical expression of the half width is given. (author)

  12. Analysis of compressive failure of layered materials by kink band broadening

    DEFF Research Database (Denmark)

    Jensen, Henrik Myhre

    1999-01-01

    Failure by steady state kink band broadening in uni-directional fibre composites or layered materials is analysed. An incremental scheme for calculation of kink band broadening stresses and lock-up conditions in the band for arbitrary material behaviour is presented. The method is illustrated...... by material data which are representative for polymer matrix composites for which experimental work exists. (C) 1999 Elsevier Science Ltd. All rights reserved....

  13. Collisional broadening of depolarized spectral lines of hydrogen gases at low temperatures

    International Nuclear Information System (INIS)

    Hout, K.D. van den.

    1978-01-01

    Experimental results are presented for the collisional broadening and shift of H 2 , D 2 and HD rotational Raman and depolarized Rayleigh lines at various temperatures between 25 K and 300 K. These are then discussed within the context of current theoretical concepts. For a few temperatures the line broadening cross sections are also reported as a function of the ortho-para composition for H 2 and D 2 . (C.F.)

  14. Color Doppler US of superficial adenopathies; Il color Doppler nelle adenopatie superficiali

    Energy Technology Data Exchange (ETDEWEB)

    Giovagnorio, F. [Rome Univ. (Italy). 1. Cattedra di Radiologia

    1999-03-01

    Superficial lymph node are frequently involved in different diseases. Their location makes them suitable for effective assessment with high-resolution US and color Doppler has been recently suggested as a tool for increasing sensitivity in lymph node studies. Thus the author investigated the main vascular patterns detectable in abnormal superficial lymph nodes. [Italian] Numerosa malattie con natura differente coinvolgono i linfonodi superficiali: la localizzazione ne consente l'esplorazione con ecografia con alta risoluzione e lo studio mediante eco color Doppler e' stato proposto negli ultimi anni incontrando notevole sviluppo in tempi recenti. Scopo del lavoro e' illustrare il contributo personale nella definizione dei principali quadri riscontrabili nelle diverse adenopatie superficiali.

  15. Signal Processing Schemes for Doppler Global Velocimetry

    Science.gov (United States)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.

    1991-01-01

    Two schemes for processing signals obtained from the Doppler global velocimeter are described. The analog approach is a simple, real time method for obtaining an RS-170 video signal containing the normalized intensity image. Pseudo colors are added using a monochromatic frame grabber producing a standard NTSC video signal that can be monitored and/or recorded. The digital approach is more complicated, but maintains the full resolution of the acquisition cameras with the capabilities to correct the signal image for pixel sensitivity variations and to remove of background light. Prototype circuits for each scheme are described and example results from the investigation of the vortical flow field above a 75-degree delta wing presented.

  16. Widefield laser doppler velocimeter: development and theory.

    Energy Technology Data Exchange (ETDEWEB)

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  17. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  18. Water absorption lines, 931-961 nm - Selected intensities, N2-collision-broadening coefficients, self-broadening coefficients, and pressure shifts in air

    Science.gov (United States)

    Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.

    1982-01-01

    Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.

  19. Seeing the big picture: Broadening attention relieves sadness and depressed mood.

    Science.gov (United States)

    Gu, Li; Yang, Xueling; Li, Liman Man Wai; Zhou, Xinyue; Gao, Ding-Guo

    2017-08-01

    We examined whether the broadened attentional scope would affect people's sad or depressed mood with two experiments, enlightened by the meaning of "seeing the big picture" and the broaden-and-build model. Experiment 1 (n = 164) is a laboratory-based experiment, in which we manipulated the attentional scope by showing participants zoomed-out or zoomed-in scenes. In Experiment 2 (n = 44), we studied how depressed mood and positive and negative emotions were affected when participants watched distant versus proximal scenes for eight weeks in real life. Healthy participants in Experiment 1, who were induced to feel sad, could return to the baseline mood after having the broadened attention task but not after having the narrowed attention task, which indicated that immediate attention broadening manipulation could function as antidotes for the lingering effects of induced negative emotions. Participants with depressed mood in Experiment 2 showed reduced depressed mood, increased positive affect, and decreased negative affect after receiving attention broadening training compared to those receiving attention narrowing training. Our findings suggest a robust role of broadened attentional scope in relieving negative emotions and even mildly depressed mood in the long run. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  20. An In-situ method for the study of strain broadening usingsynchrotronx-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu C.; Lynch, Peter A.; Cheary, Robert W.; Clark, Simon M.

    2006-12-15

    A tensonometer for stretching metal foils has beenconstructed for the study of strain broadening in x-ray diffraction lineprofiles. This device, which is designed for use on the powderdiffractometer in Station 2.3 at Daresbury Laboratory, allows in-situmeasurements to be performed on samples under stress. It can be used fordata collection in either transmission or reflection modes using eithersymmetric or asymmetric diffraction geometries. As a test case,measurements were carried out on a 18mum thick copper foil experiencingstrain levels of up to 5 percent using both symmetric reflection andsymmetric transmission diffraction. All the diffraction profilesdisplayed peak broadening and asymmetry which increased with strain. Themeasured profiles were analysed by the fundamental parameters approachusing the TOPAS peak fitting software. All the observed broadenedprofiles were modelled by convoluting a refineable diffraction profile,representing the dislocation and crystallite size broadening, with afixed instrumental profile pre-determined usinghigh quality LaB6reference powder. The de-convolution process yielded "pure" sampleintegral breadths and asymmetry results which displayed a strongdependence on applied strain and increased almost linearly with appliedstrain. Assuming crystallite size broadening in combination withdislocation broadening arising from fcc a/2<110>111 dislocations,we have extracted the variation of mechanic al property with strain. Theobservation of both peak asymmetry and broadening has been interpreted asa manifestation of a cellular structure with cell walls and cellinteriors possessing high and low dislocation densities.

  1. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H.; Iwasaki, N.; Goto, M. [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T.; Nakamura, T. [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  2. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  3. Role of colour doppler sonography in adnexal masses

    Directory of Open Access Journals (Sweden)

    Shazia Ashraf Khan, Aamina Banoo

    2014-04-01

    Full Text Available Objective: To evaluate the role of colour Doppler sonography in differentiating between benign and malignant adnexal masses. Materials & Methods: One hundred women diagnosed with adnexal masses underwent colour Doppler sonography. Resistance index (RI and Pulsatility index (PI were calculated in each case and lowest RI and PI obtained at any point in the mass were considered for analysis. Masses which were completely a vascular were considered as benign. Histopathological diagnosis was obtained in each case. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of colour Doppler were calculated. Results: Mean RI and Mean PI were significantly lower in malignant masses (0.34 & 0.95 respectively as compared to benign masses (0.72 & 1.97 respectively. Out of 81 benign cases, Doppler could correctly diagnose 78 cases as benign, but labelled 3 cases as malignant which were actually benign. Out of 19 malignant cases, 16 cases were correctly diagnosed, whereas 3 cases were missed by Doppler. Our study showed a sensitivity of 84.2%, specificity of 96.3%, positive predictive value of 84.2%, negative predictive value of 96.3% and accuracy of 94% for colour Doppler. Conclusion: Colour Doppler sonography is helpful in differentiating benign from malignant adnexal masses.

  4. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  5. The recent development of neutronic techniques for determination of residual stresses

    International Nuclear Information System (INIS)

    Lodini, A.

    2001-01-01

    Neutron diffraction is a well-established non-destructive method for the measurement of residual stress deep inside materials. This paper gives a short overview of the use of neutrons for materials research and measurement techniques. Neutron diffraction has been applied in determining residual stresses in metal matrix composites. Measurement and prediction of residual stress for plastic deformation are presented. More recently, the neutron diffraction technique has also been applied for the determination of plastic strain which results from microstructural defects and leads to peak broadening. Influence of the shot penning treatment on austenitic steel is presented. (author)

  6. Doppler spectroscopy of hydrogen Balmer lines in a hollow cathode glow discharge in ammonia and argon-ammonia mixture

    International Nuclear Information System (INIS)

    Sisovic, N. M.; Konjevic, N.

    2008-01-01

    The results of Doppler spectroscopy of hydrogen Balmer lines from a stainless steel (SS) and copper (Cu) hollow cathode (HC) glow discharge in ammonia and argon-ammonia mixture are reported. The experimental profiles in ammonia discharge are fitted well by superposing three Gaussian profiles. The half widths, in energy units, of narrow and medium Gaussians are in the ranges 0.3-0.4 eV and 3-4 eV, respectively, for both hollow cathodes what is expected on the basis of earlier electron beam→NH 3 experiments. The half widths of the largest Gaussian in ammonia are 46 and 55 eV for SS and Cu HC, respectively. In argon-ammonia discharge, three Gaussians are also required to fit experimental profiles. While half widths of narrow and medium Gaussians are similar to those in ammonia, the half widths of the largest Gaussians are 35 and 42 eV for SS and Cu HC, respectively. The half widths of the largest Gaussians in ammonia and in argon-ammonia mixture indicate the presence of excessive Doppler broadening.

  7. Pulsed Doppler echocardiographic analysis of mitral regurgitation after myocardial infarction.

    Science.gov (United States)

    Loperfido, F; Biasucci, L M; Pennestri, F; Laurenzi, F; Gimigliano, F; Vigna, C; Rossi, E; Favuzzi, A; Santarelli, P; Manzoli, U

    1986-10-01

    In 72 patients with previous myocardial infarction (MI), mitral regurgitation (MR) was assessed by pulsed-wave Doppler echocardiography and compared with physical and 2-dimensional echocardiographic findings. MR was found by Doppler in 29 of 42 patients (62%) with anterior MI, 11 of 30 (37%) with inferior MI (p less than 0.01) and in none of 20 normal control subjects. MR was more frequent in patients who underwent Doppler study 3 months after MI than in those who underwent Doppler at discharge (anterior MI = 83% vs 50%, p less than 0.01; inferior MI = 47% vs 27%, p = not significant). Of 15 patients who underwent Doppler studies both times, 3 (all with anterior MI) had MR only on the second study. Of the patients with Doppler MR, 12 of 27 (44%) with a left ventricular (LV) ejection fraction (EF) greater than 30% and 1 of 13 (8%) with an EF of 30% or less (p less than 0.01) had an MR systolic murmur. Mitral prolapse or eversion and papillary muscle fibrosis were infrequent in MI patients, whether or not Doppler MR was present. The degree of Doppler MR correlated with EF (r = -0.61), LV systolic volume (r = 0.47), and systolic and diastolic mitral anulus circumference (r = 0.52 and 0.51, respectively). Doppler MR was present in 24 of 28 patients (86%) with an EF of 40% or less and in 16 of 44 (36%) with EF more than 40% (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Predicting Factors for Successful Maturation of Autogenous Haemodialysis Fistulas After Salvage Percutaneous Transluminal Angioplasty in Diabetic Nephropathy: A Study on Follow-Up Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Jeon, Eui-Yong; Cho, Young Kwon; Cho, Sung Bum; Yoon, Dae Young; Suh, Seong O

    2016-01-01

    Maturation failure of autogenous arteriovenous fistula (aAVF) has been increasing after surgical procedures and the salvage percutaneous transluminal angioplasty (sPTA) for immature aAVF has been identified as an effective treatment modality. The aim of this study was to identify factors predicting successful aAVF maturation and to determine positive technical aspects of sPTA. We retrospectively reviewed medical records and radiological images of 59 patients who had undergone sPTA for non-maturing aAVFs. We analysed images from pre-surgical mapping Doppler ultrasonography, angiography, and angioplasty and follow-up Doppler ultrasonography performed within two weeks after sPTA. We assessed the following factors, for their ability to predict successful aAVF maturation: 1) patient factors (age; sex; co-morbidities; and aAVF age, side and type); 2) vessel factors (cephalic vein diameter and depth, presence of accessory veins, and pre- and postoperative radial artery disease); 3) lesion factors (stenosis number, location and severity); and 4) technical factors (presence of residual stenosis and anatomic success ratio (ASR) on follow-up Doppler ultrasonography). The technical and clinical success rates were both 94.9% (56/59); the mean ASR was 0.84. An ASR of ≥ 0.7 and no significant residual stenosis (< 30%) (both P < 0.001) on two-week follow-up Doppler ultrasonography predicted successful aAVF maturation. For more precise prediction of successful aAVF maturation after sPTA, short-term follow-up Doppler ultrasonography (< 2 weeks) was useful. If the ASR was < 0.7 or if residual stenosis was ≥ 30%, immediate repeat sPTA is recommended

  9. Interferometric millimeter wave and THz wave doppler radar

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  10. Residual gas analysis

    International Nuclear Information System (INIS)

    Berecz, I.

    1982-01-01

    Determination of the residual gas composition in vacuum systems by a special mass spectrometric method was presented. The quadrupole mass spectrometer (QMS) and its application in thin film technology was discussed. Results, partial pressure versus time curves as well as the line spectra of the residual gases in case of the vaporization of a Ti-Pd-Au alloy were demonstrated together with the possible construction schemes of QMS residual gas analysers. (Sz.J.)

  11. 3D-localized, high-resolution, non-perturbing, vectorizable magnetic field diagnostic using two-photon Doppler-free laser-induced fluorescence

    Science.gov (United States)

    Yoon, Young Dae; Bellan, Paul M.

    2017-10-01

    A detailed description of a new plasma magnetic field diagnostic using Doppler-free two-photon laser-induced fluorescence is presented. The diagnostic is based on a method previously developed in the context of rubidium vapor experiments. Two counter-propagating diode laser beams at 394nm are directed into an argon plasma to excite Ar-II ions from the metastable level 3s2 3p4 4 p4D7 / 2 ⟶ 3s2 3p4 4 p4D5/ 2 o ⟶ 3s2 3p4 5 s2P3 / 2 . The levels involve two similar (394.43nm and 393.31nm) transition wavelengths, so the two counter-propagating beams effectively cancel out the Doppler effect. The excited ions then decay to the 3s2 3p4 4 p2D5/ 2 o level, emitting a 410.38nm line which is to be detected by a photomultiplier tube. The Zeeman splitting - normally unobservable because of the large Doppler broadening - of the resultant fluorescence is then to be analyzed, yielding the magnetic field of the particular location. This method is expected to provide 3D localized, non-perturbing vector measurements of the magnetic field. The resolution of the diagnostic is only limited by the cross-section of the laser beam, which can easily be as small as hundreds of microns wide. An experimental implementation is currently in progress.

  12. Turbulent energy dissipation rates observed by Doppler MST Radar and by rocket-borne instruments during the MIDAS/MaCWAVE campaign 2002

    Directory of Open Access Journals (Sweden)

    N. Engler

    2005-06-01

    Full Text Available During the MIDAS/MaCWAVE campaign in summer 2002 we have observed turbulence using Doppler beam steering measurements obtained from the ALWIN VHF radar at Andøya/Northern Norway. This radar was operated in the Doppler beam steering mode for turbulence investigations during the campaign, as well as in spaced antenna mode, for continuously measuring the background wind field. The real-time data analysis of the Doppler radar backscattering provided the launch conditions for the sounding rockets. The spectral width data observed during the occurrence of PMSE were corrected for beam and shear broadening caused by the background wind field to obtain the turbulent part of the spectral width. The turbulent energy dissipation rates determined from the turbulent spectral width vary between 5 and 100mW kg-1 in the altitude range of 80-92km and increase with altitude. These estimations agree well with the in-situ measurements using the CONE sensor which was launched on 3 sounding rockets during the campaign.

  13. Turbulent energy dissipation rates observed by Doppler MST Radar and by rocket-borne instruments during the MIDAS/MaCWAVE campaign 2002

    Directory of Open Access Journals (Sweden)

    N. Engler

    2005-06-01

    Full Text Available During the MIDAS/MaCWAVE campaign in summer 2002 we have observed turbulence using Doppler beam steering measurements obtained from the ALWIN VHF radar at Andøya/Northern Norway. This radar was operated in the Doppler beam steering mode for turbulence investigations during the campaign, as well as in spaced antenna mode, for continuously measuring the background wind field. The real-time data analysis of the Doppler radar backscattering provided the launch conditions for the sounding rockets. The spectral width data observed during the occurrence of PMSE were corrected for beam and shear broadening caused by the background wind field to obtain the turbulent part of the spectral width. The turbulent energy dissipation rates determined from the turbulent spectral width vary between 5 and 100mW kg-1 in the altitude range of 80-92km and increase with altitude. These estimations agree well with the in-situ measurements using the CONE sensor which was launched on 3 sounding rockets during the campaign.

  14. Measurements of ion temperature and flow of pulsed plasmas produced by a magnetized coaxial plasma gun device using an ion Doppler spectrometer

    Science.gov (United States)

    Kitagawa, Y.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    It is important to know surface damage characteristics of plasma-facing component materials during transient heat and particle loads such as type I ELMs. A magnetized coaxial plasma gun (MCPG) device has been used as transient heat and particle source in ELM simulation experiments. Characteristics of pulsed plasmas produced by the MCPG device play an important role for the plasma material interaction. In this study, ion temperature and flow velocity of pulsed He plasmas were measured by an ion Doppler spectrometer (IDS). The IDS system consists of a light collection system including optical fibers, 1m-spectrometer and a 16 channel photomultiplier tube (PMT) detector. The IDS system measures the width and Doppler shift of HeII (468.58 nm) emission line with the time resolution of 1 μs. The Doppler broadened and shifted spectra were measured with 45 and 135 degree angles with respect to the plasmoid traveling direction. The observed emission line profile was represented by sum of two Gaussian components to determine the temperature and flow velocity. The minor component at around the wavelength of zero-velocity was produced by the stationary plasma. As the results, the ion velocity and temperature were 68 km/s and 19 eV, respectively. Thus, the He ion flow energy is 97 eV. The observed flow velocity agrees with that measured by a time of flight technique.

  15. Digital nonlinearity compensation in high-capacity optical communication systems considering signal spectral broadening effect.

    Science.gov (United States)

    Xu, Tianhua; Karanov, Boris; Shevchenko, Nikita A; Lavery, Domaniç; Liga, Gabriele; Killey, Robert I; Bayvel, Polina

    2017-10-11

    Nyquist-spaced transmission and digital signal processing have proved effective in maximising the spectral efficiency and reach of optical communication systems. In these systems, Kerr nonlinearity determines the performance limits, and leads to spectral broadening of the signals propagating in the fibre. Although digital nonlinearity compensation was validated to be promising for mitigating Kerr nonlinearities, the impact of spectral broadening on nonlinearity compensation has never been quantified. In this paper, the performance of multi-channel digital back-propagation (MC-DBP) for compensating fibre nonlinearities in Nyquist-spaced optical communication systems is investigated, when the effect of signal spectral broadening is considered. It is found that accounting for the spectral broadening effect is crucial for achieving the best performance of DBP in both single-channel and multi-channel communication systems, independent of modulation formats used. For multi-channel systems, the degradation of DBP performance due to neglecting the spectral broadening effect in the compensation is more significant for outer channels. Our work also quantified the minimum bandwidths of optical receivers and signal processing devices to ensure the optimal compensation of deterministic nonlinear distortions.

  16. Resonance broadening of Hg lines as a density diagnostic in high intensity discharge lamps

    International Nuclear Information System (INIS)

    Lawler, J E

    2004-01-01

    The use of width measurements on resonance broadened lines of Hg as a density diagnostic in high intensity discharge (HID) lamps is reviewed and further developed in this paper. Optical depths of Hg I lines at 491.6 nm, 577.0 nm, and 1014 nm are computed as a function of temperature to confirm that these lines are optically thin in most HID lamps. The effect of quadratic and quartic radial temperature variation on the width of resonance broadened lines is computed for arc core temperatures from 4000 K to 7000 K. Such variations in temperature, and inverse variations in Hg density, are found to increase the line widths by less than 10% for 'side-on' emission measurements averaged over the arc radius. Theoretical profiles of resonance broadened spectral lines, both radially averaged and as a function of chord offset, are presented. Observations of resonance broadened lines in a metal-halide HID lamp are presented and analysed. It is concluded that the widths of resonance broadened lines provide a convenient and reliable diagnostic for the arc core Hg density but are generally not very sensitive to the radial temperature and Hg density gradient

  17. CAMEX-4 MIPS 915 MHZ DOPPLER WIND PROFILER V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The University of Alabama in Huntsville (UAH) Mobile Integrated Profiling System (MIPS) is a mobile atmospheric profiling system. It includes a 915 MHz Doppler...

  18. Micro-Doppler Analysis of Rotating Target in SAR

    National Research Council Canada - National Science Library

    Thayaparan, T; Abrol, S; Qian, S

    2005-01-01

    .... The phase modulation may be seen as a time-dependent micro-Doppler (m-D) frequency. Due to their superior resolution potential, it is useful to analyze such signals with time-frequency analysis methods...

  19. Differentiation of midbrain cystic lesions by duplex Doppler US

    International Nuclear Information System (INIS)

    Horgan, J.G.; Taylor, K.J.W.; Sarwar, M.; Weltin, G.; Klier, L.

    1986-01-01

    The addition of Doppler technology to an ultrasound imaging system allows easy differentiation of vascular from nonvascular masses. In addition, the characteristic flow in different arteries, veins, and arteriovenous communications allows accurate diagnosis of vascular structures. Cystic lesions in the region of the midbrain are uncommon but not rare in neonates, and it is important to differentiate between quadrigeminal plate cysts and vein of Galen aneurysms. Six neonates with cystic midbrain structures lying above the tectum were studied over a 2-year period. All were examined with duplex Doppler imaging and followed up by CT and angiography, when indicated. In two of the six infants a highly vascular signal was demonstrated with high flow rates and low impedance. Subsequent CT and angiography revealed typical vein of Galen aneurysms. The remaining four infants had cystic lesions that were avascular on Doppler imaging and demonstrated no enhancement on CT. Duplex Doppler imaging is helpful in the initial investigation of patients with midbrain cystic lesions

  20. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Doppler Aerosol WiNd (DAWN), a pulsed lidar, operated aboard a NASA DC-8 aircraft during the Genesis and Rapid Intensification Processes (GRIP) field campaign....

  1. Apparatus and method for noninvasive particle detection using doppler spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Dipen N.

    2016-05-31

    An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.

  2. Frequency Diversity Technique for Space-borne Radar Doppler Measurements

    Data.gov (United States)

    National Aeronautics and Space Administration — Doppler velocity measurement has been challenging for radars onboard fast moving platforms (such as spacecrafts) or radars with rapid scanning antennas due to the...

  3. GPM Ground Validation Doppler on Wheels (DOW) OLYMPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Doppler on Wheels (DOW) OLYMPEX dataset was obtained by a dual-polarization and dual-frequency X-band mobile radar operated by the Center...

  4. Assimilation of Doppler weather radar observations in a mesoscale ...

    Indian Academy of Sciences (India)

    ) Doppler radar data in a numerical model for the prediction of mesoscale convective complexes around Chennai and Kolkata. Three strong convective events both over Chennai and Kolkata have been considered for the present study.

  5. Doppler Wind Lidar Measurements and Scalability to Space

    Data.gov (United States)

    National Aeronautics and Space Administration — Global measurements of wind speed and direction from Doppler wind lidars, if available, would significantly improve forecasting of severe weather events such as...

  6. Applicability of Doppler weather radar based rainfall data for runoff ...

    Indian Academy of Sciences (India)

    or flood-related studies in Indian river basins. A comparison study between. Doppler weather radar (DWR) derived rainfall data and the conventional rain gauge data was carried out with hourly inputs at one of the watersheds of Chennai basin,.

  7. Laser Doppler technology applied to atmospheric environmental operating problems

    Science.gov (United States)

    Weaver, E. A.; Bilbro, J. W.; Dunkin, J. A.; Jeffreys, H. B.

    1976-01-01

    Carbon dioxide laser Doppler ground wind data were very favorably compared with data from standard anemometers. As a result of these measurements, two breadboard systems were developed for taking research data: a continuous wave velocimeter and a pulsed Doppler system. The scanning continuous wave laser Doppler velocimeter developed for detecting, tracking and measuring aircraft wake vortices was successfully tested at an airport where it located vortices to an accuracy of 3 meters at a range of 150 meters. The airborne pulsed laser Doppler system was developed to detect and measure clear air turbulence (CAT). This system was tested aboard an aircraft, but jet stream CAT was not encountered. However, low altitude turbulence in cumulus clouds near a mountain range was detected by the system and encountered by the aircraft at the predicted time.

  8. NAMMA NASA POLARIMETRIC DOPPLER WEATHER RADAR (NPOL) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NAMMA NASA Polarimetric Doppler Weather Radar (NPOL) dataset used the NPOL, developed by a research team from Wallops Flight Facility, is a fully transportable...

  9. CAMEX-4 MIPS 915 MHZ DOPPLER WIND PROFILER V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 MIPS 915 MHZ Doppler Wind Profiler dataset was collected by the University of Alabama in Huntsville (UAH) Mobile Integrated Profiling System (MIPS),...

  10. Doppler electron velocimetry : notes on creating a practical tool.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.; Milster, Tom (University of Arizona)

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  11. Thermal Design for a Diffraction-Limited Doppler Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The Univ. of Notre Dame is building a new high-resolution spectrometer named “iLocater” to achieve unprecedented radial velocity (RV) precision for stellar Doppler...

  12. Muscle activity characterization by laser Doppler Myography

    International Nuclear Information System (INIS)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Tomasini, Enrico Primo

    2013-01-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin

  13. Hydronephrosis and pregnancy: study with Doppler echography

    International Nuclear Information System (INIS)

    Ripolles Gonzalez, T.R.; Ambit Capdevilla, S.; Sanguesa Nebot, C.; Lazaro, S. de; Garcia Vila, J.H.; Belloch Ugarte, V.

    1993-01-01

    An 18-month study was performed to establish the normal intrarenal resistance index during pregnancy, in order to determine whether it differed significantly depending on the week of gestation or the degree of hydronephrosis. For this purpose , the flow velocity waves obtained in right kidney were analyzed in a group of 112 patients on the basis of 209 explorations. The kidneys were classified as grade 0,I,II, or III according to the degree of hydronephrosis. Doppler signal sampling was carried out at the level of the corticomedullary junction. From the results of the study it can be deduced that the index of intrarenal resistance during pregnancy is similar to that of the general population, that there are no significant differences among the groups with different degree of hydronephrosis and that the index does not vary according to the different weeks of gestation. These findings suggest that, during pregnancy, a pathological resistance index in a kidney should not be attributed to the physiological changes associated with normal gestation. (Author) 21 refs

  14. Muscle activity characterization by laser Doppler Myography

    Science.gov (United States)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  15. Doppler time-of-flight imaging

    KAUST Repository

    Heide, Felix

    2015-07-30

    Over the last few years, depth cameras have become increasingly popular for a range of applications, including human-computer interaction and gaming, augmented reality, machine vision, and medical imaging. Many of the commercially-available devices use the time-of-flight principle, where active illumination is temporally coded and analyzed on the camera to estimate a per-pixel depth map of the scene. In this paper, we propose a fundamentally new imaging modality for all time-of-flight (ToF) cameras: per-pixel velocity measurement. The proposed technique exploits the Doppler effect of objects in motion, which shifts the temporal frequency of the illumination before it reaches the camera. Using carefully coded illumination and modulation frequencies of the ToF camera, object velocities directly map to measured pixel intensities. We show that a slight modification of our imaging system allows for color, depth, and velocity information to be captured simultaneously. Combining the optical flow computed on the RGB frames with the measured metric axial velocity allows us to further estimate the full 3D metric velocity field of the scene. We believe that the proposed technique has applications in many computer graphics and vision problems, for example motion tracking, segmentation, recognition, and motion deblurring.

  16. Intrahepatic portosystemic venous shunts: diagnosis by Doppler ultrasound; Cortocircuitos venosos portosistemicos intrahepaticos: diagnostico mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Garofano, M. P.; Medina, A.; Lopez, G.; Garrido, C. [Hospital Universitario Virgen de las Nieves. Granada (Spain)

    2001-07-01

    Intrahepatic portosystemic venous shunts are venous vascular lesions that allow intrahepatic portal vessels to communicate with hepatic veins. They may present in patients with portal hypertension or b discovered incidentally; it is considered that the latter may be congenital or acquired. A noninvasive methods. Doppler ultrasound aids in the diagnosis of these anomalous communications by providing images of the vessels and the direction, velocity and volume of the blood flow through the shunt. We present four cases of intrahepatic portosystemic venous shunt. (Author) 8 refs.

  17. Laser Doppler measurements in two-phase flows

    International Nuclear Information System (INIS)

    Durst, F.; Zare, M.

    1976-01-01

    Basic theory for laser-Doppler velocity measurements of large reflecting or refracting surfaces is provided. It is shown that the Doppler-signals contain information of the velocity and size of the large bodies, and relationships for transforming velocity and radius of curvature of moving spheres are presented. Preliminary experiments verified the analytical findings and demonstrated the applicability of the method to some two-phase flows

  18. Optimized variational analysis scheme of single Doppler radar wind data

    Science.gov (United States)

    Sasaki, Yoshi K.; Allen, Steve; Mizuno, Koki; Whitehead, Victor; Wilk, Kenneth E.

    1989-01-01

    A computer scheme for extracting singularities has been developed and applied to single Doppler radar wind data. The scheme is planned for use in real-time wind and singularity analysis and forecasting. The method, known as Doppler Operational Variational Extraction of Singularities is outlined, focusing on the principle of local symmetry. Results are presented from the application of the scheme to a storm-generated gust front in Oklahoma on May 28, 1987.

  19. Application of Total Variation Minimization to Doppler Tomography

    Directory of Open Access Journals (Sweden)

    M. Uemura

    2015-02-01

    Full Text Available We have developed a new model of the Doppler tomography using total variation minimization (DTTVM. We demonstrated that this method can reconstruct localized and non-axisymmetric profiles possibly having sharp edges in the Doppler map. We apply this model to the real data of the dwarf nova, WZ Sge in superoutburst. DTTVM can reproduce the observed spectra with a high precision, while the previous models fail to reproduce localized sources.

  20. Transcranial Doppler ultrasound and cerebral angiography - alternative or complementary

    International Nuclear Information System (INIS)

    Bockenheimer, S.; Lorey, N.

    1985-01-01

    Transcranial Doppler ultrasound is a noninvasive method of recording the flow velocity of larger intracranial vessels. The impact on diagnosis of cerebravascular occlusive disease is not yet evaluated. We present 15 patients, age range 39-73 years, who suffered from completed stroke. The findings of transcranial Doppler ultrasound and of cerebral angiography are presented. The value of both methods in treatment strategy is discussed. (orig.) [de

  1. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  2. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  3. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  4. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  5. Analysis of Radar Doppler Signature from Human Data

    Directory of Open Access Journals (Sweden)

    M. ANDRIĆ

    2014-04-01

    Full Text Available This paper presents the results of time (autocorrelation and time-frequency (spectrogram analyses of radar signals returned from the moving human targets. When a radar signal falls on the human target which is moving toward or away from the radar, the signals reflected from different parts of his body produce a Doppler shift that is proportional to the velocity of those parts. Moving parts of the body causes the characteristic Doppler signature. The main contribution comes from the torso which causes the central Doppler frequency of target. The motion of arms and legs induces modulation on the returned radar signal and generates sidebands around the central Doppler frequency, referred to as micro-Doppler signatures. Through analyses on experimental data it was demonstrated that the human motion signature extraction is better using spectrogram. While the central Doppler frequency can be determined using the autocorrelation and the spectrogram, the extraction of the fundamental cadence frequency using the autocorrelation is unreliable when the target is in the clutter presence. It was shown that the fundamental cadence frequency increases with increasing dynamic movement of people and simultaneously the possibility of its extraction is proportional to the degree of synchronization movements of persons in the group.

  6. Curriculum of broaden education and theory of teaching activity in school Physical Education

    Directory of Open Access Journals (Sweden)

    Sirléia Silvano

    2016-05-01

    Full Text Available This paper focuses on the conception of curriculum with broaden character in Physical Education and Davidov and Leontiev’s learning theory as possibility of focusing on human education in the omnilateral perspective. We endorse the necessity that the curriculum dynamics – dealing with knowledge, school systematization and standardization of school practices – becomes effective in a curriculum of broaden character. We consider that dealing with knowledge involves the necessity to create conditions that promote the transmission and assimilation of school knowledge. We refer therefore to a scientific direction of the teaching process, in other words, that the teacher leads the student to enter into study activity; from abstract knowledge rising to concrete theoretical knowledge, which is brought about by curriculum organization from a broaden conception.

  7. Soliton broadening under random dispersion fluctuations: Importance sampling based on low-dimensional reductions

    Science.gov (United States)

    Moore, Richard O.; Schäfer, Tobias; Jones, Christopher K. R. T.

    2005-12-01

    We demonstrate that dispersion-managed solitons are less likely to experience critical broadening under the influence of random dispersion fluctuations than are solitons of the integrable nonlinear Schrödinger equation, and that this robustness increases with map strength from the constant-dispersion (integrable) limit to the large-map-strength limit. To achieve this, we exploit a separation of scales in dispersion-managed soliton dynamics to implement an importance-sampled Monte Carlo approach that determines the probability of rare broadening events. This approach reconstructs the tails (i.e., the regions of practical importance) of probability distribution functions with an efficiency that is several orders of magnitude greater than conventional Monte Carlo simulations. We further show that the variational approach with an appropriately scaled ansatz is surprisingly good at capturing the effect of random dispersion on pulse broadening; where it fails, it can still be used to guide very efficient simulation of the original equation.

  8. Gamma-ray emission spectrum from thermonuclear fusion reactions without intrinsic broadening

    DEFF Research Database (Denmark)

    Nocente, M.; Källne, J.; Salewski, Mirko

    2015-01-01

    First principle calculations of the gamma-ray energy spectrum arising from thermonuclear reactions without intrinsic broadening in fusion plasmas are presented, extending the theoretical framework needed to interpret measurements up to the accuracy level enabled by modern high resolution instrume...... information that can be extracted from the gamma-ray emission spectrum of fusion reactions without intrinsic broadening and are of relevance for applications to high performance plasmas of present and next generation devices.......First principle calculations of the gamma-ray energy spectrum arising from thermonuclear reactions without intrinsic broadening in fusion plasmas are presented, extending the theoretical framework needed to interpret measurements up to the accuracy level enabled by modern high resolution...... instruments. An analytical formula for the spectrum from Maxwellian plasmas, which extends to higher temperatures than the results previously available in the literature, has been derived and used to discuss the assumptions and limitations of earlier models. In case of radio-frequency injection, numerical...

  9. Agricultural pesticide residues

    International Nuclear Information System (INIS)

    Fuehr, F.

    1984-01-01

    The utilization of tracer techniques in the study of agricultural pesticide residues is reviewed under the following headings: lysimeter experiments, micro-ecosystems, translocation in soil, degradation of pesticides in soil, biological availability of soil-applied substances, bound residues in the soil, use of macro- and microautography, double and triple labelling, use of tracer labelling in animal experiments. (U.K.)

  10. The effect of residual ventricular septal defects on early clinical outcome: initial experience

    International Nuclear Information System (INIS)

    Zaman, H.; Cheema, M.A.; Jalal, A.

    2000-01-01

    Residual ventricular septal defect (VSD)after repair of isolated VSD or Fallot's tetralogy is one of the main causes of morbidity and re-operations. In this paper we have presented the results of out initial experience regarding the management of this problem. The data consists of 71 patients (22 isolated VSD and 29 fallout's tetralogy) operate during January 1991 to July, 1993. The incidence of residual VSD as shown by color doppler study at the time of discharge from hospital and at three month's follow-up was 3 out of 60 patients(73%) and 12 out of to (20%) respectively. Six out of these 12 patients were NYHA class III-IV who underwent cardiac catheterization which revealed patch dehiscence in two patients and residual right ventricular outflow tract obstruction in four patients. The two patients, with patch dehiscence were reported successfully with very good outcome. Simple color doppler mapping tends to over-diagnose residual VSDs since it can pick up small haemodynamically insignificant leaks around stitches and needle holes which seal off in due course. The findings of color doppler should, therefore, be correlated with actual clinical outcome in order to proceed with further investigation and re-operation. (author)

  11. The density broadening in a sodium F=2 condensate detected by a pulse train

    Directory of Open Access Journals (Sweden)

    Jianing Han

    2011-09-01

    Full Text Available The dipole-blockaded sodium clock transition has been detected by high resolution microwave spectroscopy, the multiple-pulse spectroscopy. This spectroscopic technique has been first used to detect the density broadening and shifting in a Sodium Bose Einstein Condensate (BEC by probing the sodium clock-transition. Moreover, by narrowing the pulse-width of the pulses, some of the broadening mechanisms can be partially reduced. The results reported here are essential steps toward the ground-state quantum computing, few-body spectroscopy, spin squeezing and quantum metrology.

  12. Broadening of ICRH produced fast ion profiles due to orbit effects

    International Nuclear Information System (INIS)

    Eriksson, L.-G.; Porcelli, F.

    1991-01-01

    In the JET tokamak, minority ions accelerated by ICRH reach energies in the MeV range. Near the plasma magnetic axis, the standard trapped particle ''banana'' orbit is distorted into a ''potato'' or ''fat banana'' orbit. The zero banana width approximation which is used in most Fokker-Planck calculations of velocity distributions of resonating ions is often not valid in JET. The inclusion of finite banana width effects will, in general, lead to a lowering of the averaged tail energy and a broadening of pressure profiles, power transfer profiles etc. A model for calculating orbit broadened profiles is presented. (Author)

  13. Acousto-optics bandwidth broadening in a Bragg cell based on arbitrary synthesized signal methods.

    Science.gov (United States)

    Peled, Itay; Kaminsky, Ron; Kotler, Zvi

    2015-06-01

    In this work, we present the advantages of driving a multichannel acousto-optical deflector (AOD) with a digitally synthesized multifrequency RF signal. We demonstrate a significant bandwidth broadening of ∼40% by providing well-tuned phase control of the array transducers. Moreover, using a multifrequency, complex signal, we manage to suppress the harmonic deflections and return most of the spurious energy to the main beam. This method allows us to operate the AOD with more than an octave of bandwidth with negligible spurious energy going to the harmonic beams and a total bandwidth broadening of over 70%.

  14. A prospective analysis of free flap monitoring techniques: physical examination, external Doppler, implantable Doppler, and tissue oximetry.

    Science.gov (United States)

    Lohman, Robert F; Langevin, Claude-Jean; Bozkurt, Mehmet; Kundu, Neilendu; Djohan, Risal

    2013-01-01

    No universally accepted method of flap monitoring exists, and several techniques are in use. Repeated physical examination is most popular and is often supplemented with a handheld, external Doppler, and/or implantable Doppler probes; near-infrared spectroscopy is less commonly used. We investigated the nursing and resident house staff's experience and confidence with physical exam for flap monitoring. Also, a consecutive series of 38 patients with free flaps were monitored using physical examination, external Doppler, implantable arterial and venous Doppler probes, and near-infrared spectroscopy. Five patients developed signs of microvascular complications within 3 days of surgery; all were explored and salvaged. Neither the residents nor the nursing staff were universally trained or experienced in flap monitoring by physical exam. In all patients, changes in the appearance of the flap suggestive of a microvascular complication lagged 30 to 60 minutes after the adjunctive monitoring methods indicated that a problem had occurred. Near-infrared spectroscopy was the first warning sign in four of the five patients. Two patients were explored before thrombosis of the anastomoses occurred. Near-infrared spectroscopy may identify early microvascular complications more reliably than physical examination, external Doppler, or implantable Doppler. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Analysis of airborne Doppler lidar, Doppler radar and tall tower measurements of atmospheric flows in quiescent and stormy weather

    Science.gov (United States)

    Bluestein, H. B.; Doviak, R. J.; Eilts, M. D.; Mccaul, E. W.; Rabin, R.; Sundara-Rajan, A.; Zrnic, D. S.

    1986-01-01

    The first experiment to combine airborne Doppler Lidar and ground-based dual Doppler Radar measurements of wind to detail the lower tropospheric flows in quiescent and stormy weather was conducted in central Oklahoma during four days in June-July 1981. Data from these unique remote sensing instruments, coupled with data from conventional in-situ facilities, i.e., 500-m meteorological tower, rawinsonde, and surface based sensors, were analyzed to enhance understanding of wind, waves and turbulence. The purposes of the study were to: (1) compare winds mapped by ground-based dual Doppler radars, airborne Doppler lidar, and anemometers on a tower; (2) compare measured atmospheric boundary layer flow with flows predicted by theoretical models; (3) investigate the kinematic structure of air mass boundaries that precede the development of severe storms; and (4) study the kinematic structure of thunderstorm phenomena (downdrafts, gust fronts, etc.) that produce wind shear and turbulence hazardous to aircraft operations. The report consists of three parts: Part 1, Intercomparison of Wind Data from Airborne Lidar, Ground-Based Radars and Instrumented 444 m Tower; Part 2, The Structure of the Convective Atmospheric Boundary Layer as Revealed by Lidar and Doppler Radars; and Part 3, Doppler Lidar Observations in Thunderstorm Environments.

  16. Longitudinal study of aortic isthmus Doppler in appropriately grown and small-for-gestational-age fetuses with normal and abnormal umbilical artery Doppler.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-04-01

    To establish reference ranges using longitudinal data for aortic isthmus (AoI) Doppler indices in appropriate-for-gestational-age (AGA) fetuses and to document the longitudinal trends in a cohort of small-for-gestational-age (SGA) fetuses with normal umbilical artery Doppler and in fetuses with intrauterine growth restriction (IUGR) and abnormal umbilical artery Doppler.

  17. Handling of Solid Residues

    International Nuclear Information System (INIS)

    Medina Bermudez, Clara Ines

    1999-01-01

    The topic of solid residues is specifically of great interest and concern for the authorities, institutions and community that identify in them a true threat against the human health and the atmosphere in the related with the aesthetic deterioration of the urban centers and of the natural landscape; in the proliferation of vectorial transmitters of illnesses and the effect on the biodiversity. Inside the wide spectrum of topics that they keep relationship with the environmental protection, the inadequate handling of solid residues and residues dangerous squatter an important line in the definition of political and practical environmentally sustainable. The industrial development and the population's growth have originated a continuous increase in the production of solid residues; of equal it forms, their composition day after day is more heterogeneous. The base for the good handling includes the appropriate intervention of the different stages of an integral administration of residues, which include the separation in the source, the gathering, the handling, the use, treatment, final disposition and the institutional organization of the administration. The topic of the dangerous residues generates more expectation. These residues understand from those of pathogen type that are generated in the establishments of health that of hospital attention, until those of combustible, inflammable type, explosive, radio-active, volatile, corrosive, reagent or toxic, associated to numerous industrial processes, common in our countries in development

  18. Comparison between oscillometric- and Doppler-ABI in elderly individuals

    Directory of Open Access Journals (Sweden)

    Takahashi I

    2013-03-01

    Full Text Available Ikuno Takahashi,1,3 Kyoji Furukawa,2 Waka Ohishi,1 Tetsuya Takahashi,3 Masayasu Matsumoto,3 Saeko Fujiwara11Department of Clinical Studies, 2Department of Statistics, Radiation Effects Research Foundation (RERF, Hiroshima, Japan; 3Department of Clinical Neuroscience and Therapeutics, Hiroshima University, Hiroshima, JapanAbstract: Peripheral arterial disease (PAD generally remains under-recognized, mainly due to the specialized technical skills required to detect the low values of the ankle-brachial index (ABI. As a simpler and faster alternative to the standard method using continuous-wave Doppler ultrasound, we evaluated automated oscillometric ABI measurement by VP-2000 with an elderly cohort of 113 subjects (age range, 61 to 88 years. The standard deviation in ABIs measured by the Doppler method was statistically greater than that measured by the oscillometric method for each of the two legs (P < 0.001. Correlations in ABIs between the two methods were 0.46 for the left leg and 0.61 for the right leg; this result appears to have been caused by interobserver variation in the Doppler ABI measurements. While the trend showing greater differences between average oscillometric- and Doppler-ABIs was significant at the lower ABI ranges, there was little indication of differences in measurements having an average ABI > 1.1. The difference between the methods was suggestively larger in subjects who were smokers than in non-smokers (P = 0.09, but the difference was not affected by other potential atherosclerotic risk factors, including age at examination (P > 0.50. A larger difference at lower ABIs led to better PAD detection by the Doppler method compared to the oscillometric method (sensitivity = 50%, specificity = 100%, although the overall agreement was not small (Cohen's Kappa = 0.65. Our findings indicate that oscillometric devices can provide more accurate estimation of the prevalence of PAD in elderly individuals than the conventional Doppler

  19. Cross-correlation Doppler global velocimetry (CC-DGV)

    Science.gov (United States)

    Cadel, Daniel R.; Lowe, K. Todd

    2015-08-01

    A flow velocimetry method, cross-correlation Doppler global velocimetry (CC-DGV), is presented as a robust, simplified, and high dynamic range implementation of the Doppler global/planar Doppler velocimetry technique. A sweep of several gigahertz of the vapor absorption spectrum is used for each velocity sample, with signals acquired from both Doppler-shifted scattered light within the flow and a non-Doppler shifted reference beam. Cross-correlation of these signals yields the Doppler shift between them, averaged over the duration of the scan. With presently available equipment, velocities from 0 ms-1 to over 3000 ms-1 can notionally be measured simultaneously, making the technique ideal for high speed flows. The processing routine is shown to be robust against large changes in the vapor pressure of the iodine cell, benefiting performance of the system in facilities where ambient conditions cannot be easily regulated. Validation of the system was performed with measurements of a model wind turbine blade boundary layer made in a 1.83 m by 1.83 m subsonic wind tunnel for which laser Doppler velocimetry (LDV) measurements were acquired alongside the CC-DGV results. CC-DGV uncertainties of ±1.30 ms-1, ±0.64 ms-1, and ±1.11 ms-1 were determined for the orthogonal stream-wise, transverse-horizontal, and transverse-vertical velocity components, and root-mean-square deviations of 2.77 ms-1 and 1.34 ms-1 from the LDV validation results were observed for Reynolds numbers of 1.5 million and 2 million, respectively. Volumetric mean velocity measurements are also presented for a supersonic jet, with velocity uncertainties of ±4.48 ms-1, ±16.93 ms-1, and ±0.50 ms-1 for the orthogonal components, and self-validation done by collapsing the data with a physical scaling.

  20. Independent component analysis of inhomogeneous broadening in perturbed angular correlation spectroscopy

    Science.gov (United States)

    Stufflebeam, Michael; Hodges, Jeffery A.; Park, Tyler; Evenson, W.; Matheson, P.; Zacate, M. O.

    2008-10-01

    Independent component analysis (ICA) of electric field gradient (EFG) tensor components has proven useful in analysis of inhomogeneous broadening in perturbed angular correlation (PAC). We have simulated PAC spectra for various concentrations (0.1% to 15%) of randomly distributed defects with a near- neighbor vacancy in simple cubic and face-centered cubic crystal structures. In analyzing this simulation, we used ICA to transform the Vxx and Vzz EFG components to find a joint probability distribution function for the EFGs. ICA allowed us to separate the components and develop the joint probability function as a product of the probability distributions for two independent coordinates. Then we found the broadened G2(t) by integration over the joint probability distribution function. We have compared these results to simulated G2(t) functions, allowing us to analyze the concentration dependence of the broadened PAC spectrum. This work will be applied initially to broadened PAC data from β-Mn, Al-doped β-Mn, and Sr2RuO4.

  1. Pulse sequences for dynamical decoupling in an optical lattice broadened by temporal frequency drift

    Science.gov (United States)

    Paul, Christopher R.; Zhuang, Chao; Cruz, Luciano S.; Maneshi, Samansa; Steinberg, Aephraim M.

    2009-05-01

    Despite the very long internal coherence time, transverse drift through an inhomogeneously broadened lattice leads to a rapid decay of a pulse-echo signal. We use higher-order echoes, or dynamical decoupling, to probe and subsequently eliminate the effects of this drift. We study the optimal structure of these pulse sequences for simultaneously canceling out different orders of the effect.

  2. Calculation of the Raman line broadening on carbonation in synthetic hydroxyapatite

    NARCIS (Netherlands)

    de Mul, F.F.M.; Otto, Cornelis; Greve, Jan; Arends, J.; ten Bosch, J.J.

    1988-01-01

    The position and broadening of the Raman band associated with the phosphate symmetric stretching vibration in hydroxyapatite are simulated using a simple inter- and intra-ionic potential. The results are compared with experimental values. This comparison was made as a function of the incorporation

  3. Research component in MIS curriculum: A move towards broadening the radiography spectrum in scaling professional heights

    International Nuclear Information System (INIS)

    Kilaha, S.N.

    2006-01-01

    This paper attempts to provide an insight into what research is, why it is important for radiographers (Medical Imaging Technologists), the process of carrying out research in imaging technology, the potential areas for evidence - based research activities in the profession and how research can broaden the radiography spectrum in a bid to scale the professional heights

  4. X-ray and neutron diffraction line broadening measurements in a martensitic steel for fusion technology

    International Nuclear Information System (INIS)

    Coppola, R.; Lukas, P.; Vrana, M.; Montanari, R.; Rustichelli, F.

    1995-01-01

    X-ray and neutron diffraction line broadening measurements have been carried out on a modified martensitic steel DIN 1.4914 for fusion technology (MANET) after quenching followed by tempering treatments at 700C. The results of the two experiments are discussed with reference to Cr redistribution phenomena in the matrix

  5. Reducing the impact of inhomogeneous broadening on quantum dot based electromagnetically induced transparency

    DEFF Research Database (Denmark)

    Hansen, Per Lunnemann; Mørk, Jesper

    2009-01-01

    Slow light based on electromagnetically induced transparency in an inhomogeneously broadened quantum dot medium is investigated theoretically. Three schemes, , V, and Λ, are compared and it is shown that the V-scheme gives a group velocity that is more than three orders of magnitude smaller...

  6. Shift and broadening of emission lines in Nd :YAG laser crystal ...

    Indian Academy of Sciences (India)

    threshold power and frequency stability of the lasers and obstruct the lasing performance. [1–4]. Modelling of ... and pumping energy dependency of spectral linewidth and line broadening to ensure a good control on ... is due to spontaneous one-phonon emission, and as the energy separation between the. Stark levels is in ...

  7. Improving Enzyme Activity and Broadening Selectivity for Biological Desulfurization and Upgrading of Petroleum Feedstocks

    Energy Technology Data Exchange (ETDEWEB)

    Abhijeet P. Borole; Choo Y. Hamilton; Karen Miller; Brian Davison; Matthew Grossman; Robert Shong

    2003-05-12

    The objective of this project was to develop improved biocatalysts for desulfurization and upgrading of petroleum feedstocks. The goal was to improve the activity and broaden the selectivity of desulfurization enzymes using directed evolution as a tool as well as to explore the impact of ring-opening on biological desulfurization

  8. X-ray peak broadening analysis of Fe50Ni50 nanocrystalline alloys ...

    Indian Academy of Sciences (India)

    Administrator

    Abstract. Fe50Ni50 nanocrystalline alloys were prepared by mechanical alloying method at different milling times of 2, 5, 10, 30, 50 and 70 h and ball powder ratios (BPR) of 10 : 1, 20 : 1 and 30 : 1. The structures of prepared powders were studied by X-ray diffraction (XRD). The broadening of the diffraction peaks were.

  9. Broadening the definition of resilience and "reappraising" the use of appetitive motivation.

    Science.gov (United States)

    Soenke, Melissa; O'Connor, Mary-Frances; Greenberg, Jeff

    2015-01-01

    Kalisch et al.'s PASTOR model synthesizes current knowledge of resilience, focusing on mechanisms as a common pathway to outcomes and highlighting neuroscience as a method for exploring this. We propose the model broaden its definition of resiliency to include positive indices of recovery, include positive affect as a mechanism, and approach motivation as distinct from overcoming aversive motivation.

  10. Broaden Engineering Technology students' knowledge through hands-on with motion robotics

    Science.gov (United States)

    The skills and knowledge that employers value most are not always well-aligned with undergraduate engineering technology programs. With the support of a federal grant, we identify and propose to broaden the undergraduate student experience to include training in transferable skills with agricultura...

  11. Broadening Access to Algebra I: The Impact on Eighth Graders Taking an Online Course. [Research Brief

    Science.gov (United States)

    Heppen, Jessica

    2012-01-01

    Online courses are increasingly seen as a viable way to expand the number and types of courses offered and broadening access to key courses, particularly in small and rural schools. Algebra I in middle school exemplifies an important course that educators and policymakers want to be more available to students. To study the effectiveness of using…

  12. A scheme comparison of Autler-Townes based slow light in inhomogeneously broadened quantum dot media

    DEFF Research Database (Denmark)

    Hansen, Per Lunnemann; Mørk, Jesper

    2010-01-01

    We propose a method to achieve significant optical signal delays exploiting the effect of Autler–Townes splitting (ATS) in an inhomogeneously broadened quantum dot medium. The absorption and slowdown effects are compared for three schemes i.e., Ξ, V, and Λ, corresponding to different excitation...

  13. Shift and broadening of emission lines in Nd 3: YAG laser crystal ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 86; Issue 6. Shift and broadening of emission lines in Nd3+:YAG laser crystal influenced by input energy. POURMAND SEYED EBRAHIM REZAEI ... Keywords. Nd3+:YAG crystal; heat generation; three-level emission lines; four-level emission lines; input energy.

  14. An Experiment to Demonstrate the Energy Broadening of Annihilation Gamma Rays

    Science.gov (United States)

    Ouseph, P. J.; DuBard, James L.

    1978-01-01

    Shows that when positions annihilate in solid materials the energy distribution of the annihilation gamma rays is much broader than that of a 0.511-Mev gamma peak. This broadening is caused by the momentum distribution of the electrons in the material. (Author/GA)

  15. The Broadening of Activities in the Financial System : Implications for Financial Stability and Regulation

    NARCIS (Netherlands)

    Wagner, W.B.

    2006-01-01

    Conglomeration and consolidation in the financial system broaden the activities financial institutions are undertaking and cause them to become more homogenous.Although resulting diversification gains make each institution appear less risky, we argue that financial stability may not improve as total

  16. Influence of multiple small-angle neutron scattering on diffraction peak broadening in ferritic steel

    Czech Academy of Sciences Publication Activity Database

    Woo, W.; Em, V.; Shin, E.; Mikula, Pavol; Ryukhtin, Vasyl

    2015-01-01

    Roč. 48, APR (2015), s. 350-356 ISSN 0021-8898 R&D Projects: GA ČR GB14-36566G; GA MŠk(CZ) LM2011019 Institutional support: RVO:61389005 Keywords : peak broadening * small-angle neutron scattering * neutron diffraction * magnetic domain Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.720, year: 2014

  17. [Residual neuromuscular blockade].

    Science.gov (United States)

    Fuchs-Buder, T; Schmartz, D

    2017-06-01

    Even small degrees of residual neuromuscular blockade, i. e. a train-of-four (TOF) ratio >0.6, may lead to clinically relevant consequences for the patient. Especially upper airway integrity and the ability to swallow may still be markedly impaired. Moreover, increasing evidence suggests that residual neuromuscular blockade may affect postoperative outcome of patients. The incidence of these small degrees of residual blockade is relatively high and may persist for more than 90 min after a single intubating dose of an intermediately acting neuromuscular blocking agent, such as rocuronium and atracurium. Both neuromuscular monitoring and pharmacological reversal are key elements for the prevention of postoperative residual blockade.

  18. TENORM: Wastewater Treatment Residuals

    Science.gov (United States)

    Water and wastes which have been discharged into municipal sewers are treated at wastewater treatment plants. These may contain trace amounts of both man-made and naturally occurring radionuclides which can accumulate in the treatment plant and residuals.

  19. Propagation effects on the Doppler frequency shift of satellite transmissions

    Science.gov (United States)

    Millman, G. H.; Arabadjis, M. C.

    1984-10-01

    The refraction phenomenon in the troposphere and the ionosphere causes an error in the Doppler frequency shift of radio transmissions emitted from a nonstationary satellite and received on the ground. Estimates are made of the Doppler error for various atmospheric and solar-geophysical conditions and are applicable for frequencies in the VHF to UHF range and above. The Doppler error imposed by the troposphere is directly proportional to frequency while, in the case of the ionosphere, the error is approximately inversely proportional to the frequency and approximately directly proportional to the vertical electron content. Under average tropospheric conditions, the tropospheric contribution to the Doppler error is predominant for frequencies on the order of 400 MHz and above. Below about 400 MHz, the ionospheric refraction effects are prevalent. The Doppler effects can be compensated for, to some extent, when the angular bending and the space vehicle velocity are known. Estimates of the angular bending due to the troposphere can be made to a fair degree of accuracy, from measurements of the surface refractivity. For the ionosphere, the vertical electron content data can be used for the estimation of the refraction angle error.

  20. Precise Doppler shift compensation in the hipposiderid bat, Hipposideros armiger.

    Science.gov (United States)

    Schoeppler, Diana; Schnitzler, Hans-Ulrich; Denzinger, Annette

    2018-03-15

    Bats of the Rhinolophidae and Hipposideridae families, and Pteronotus parnellii, compensate for Doppler shifts generated by their own flight movement. They adjust their call frequency such that the frequency of echoes coming from ahead fall in a specialized frequency range of the hearing system, the auditory fovea, to evaluate amplitude and frequency modulations in echoes from fluttering prey. Some studies in hipposiderids have suggested a less sophisticated or incomplete Doppler shift compensation. To investigate the precision of Doppler shift compensation in Hipposideros armiger, we recorded the echolocation and flight behaviour of bats flying to a grid, reconstructed the flight path, measured the flight speed, calculated the echo frequency, and compared it with the resting frequency prior to each flight. Within each flight, the average echo frequency was kept constant with a standard deviation of 110 Hz, independent of the flight speed. The resting and reference frequency were coupled with an offset of 80 Hz; however, they varied slightly from flight to flight. The precision of Doppler shift compensation and the offset were similar to that seen in Rhinolophidae and P. parnellii. The described frequency variations may explain why it has been assumed that Doppler shift compensation in hipposiderids is incomplete.

  1. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  2. Color Doppler US in the acute scrotal disease

    International Nuclear Information System (INIS)

    Cha, Yoo Mi; Yang, Dal Mo; Kang, Sook Wook; Kim, Hyung Sik; Lee, Young Seok; Kim, Hyeon Hoe

    1993-01-01

    To evaluate the utility of Color doppler US in the patients with acute scrotal pain, we retrospectively analyzed 37 patients referred for Color Doppler US of the scrotum. The diagnosis was confirmed by means of appropriate response to antibiotic treatment (31 cases) or surgery (6 cases). Thirty one of 37 patients were diagnosed as inflammatory disease (24 cases of epididymitis, 7 cases of epididymo-orchitis). Twenty three of 24cases of epididymitis had increased epididymal flow, while 6 of 7 cases of epididymo-orchitis had increased epididymal and testicular flow. Five patients were confirmed as testicular torsion, and in all cases nointratesticular blood flow was identified on the symptomatic side. In one case of torsion of appendix testis, epididymis was enlarged and there were increased signals suggesting epididymitis on Color Doppler US, but was confirmed by surgery as torsion of appendix testis. Therefore, the differentiation between torsion and inflammatory disease was possible by using Color Doppler US of the scrotum in 34 of 37 cases in our study. On the basis of our results, we may conclude that Color Doppler US can simultaneously display blood flow and detailed anatomic images, and function as an effective means of evaluating patients with acute scrotal disease

  3. High-resolution Doppler model of the human gait

    Science.gov (United States)

    Geisheimer, Jonathan L.; Greneker, Eugene F., III; Marshall, William S.

    2002-07-01

    A high resolution Doppler model of the walking human was developed for analyzing the continuous wave (CW) radar gait signature. Data for twenty subjects were collected simultaneously using an infrared motion capture system along with a two channel 10.525 GHz CW radar. The motion capture system recorded three-dimensional coordinates of infrared markers placed on the body. These body marker coordinates were used as inputs to create the theoretical Doppler output using a model constructed in MATLAB. The outputs of the model are the simulated Doppler signals due to each of the major limbs and the thorax. An estimated radar cross section for each part of the body was assigned using the Lund & Browder chart of estimated body surface area. The resultant Doppler model was then compared with the actual recorded Doppler gait signature in the frequency domain using the spectrogram. Comparison of the two sets of data has revealed several identifiable biomechanical features in the radar gait signature due to leg and body motion. The result of the research shows that a wealth of information can be unlocked from the radar gait signature, which may be useful in security and biometric applications.

  4. Doppler sonographic assessment of posttraumatic reflex sympathetic dystrophy.

    Science.gov (United States)

    Pekindil, Gökhan; Pekindil, Yesim; Sarikaya, Ali

    2003-04-01

    To reveal the arterial Doppler sonographic findings in cases of posttraumatic reflex sympathetic dystrophy Eleven patients had hand reflex sympathetic dystrophy, and 9 had foot reflex sympathetic dystrophy. The duration of symptoms ranged from 1 to 28 weeks, and the history of fracture ranged from 6 to 48 weeks. Bilateral brachial or popliteal arteries proximal to injuries were evaluated by Doppler sonography with a 7.5-MHz linear transducer. All patients also had triphasic bone scintigraphy and extremity thermography Two patients had monophasic waveforms and 4 had low-pulsatility triphasic waveforms on the affected limbs when compared with the asymptomatic limbs. All opposite asymptomatic limbs had normal triphasic waveforms in these 6 cases. Spectral analysis revealed a loss or decrease of a normal reversed flow component with a reduced pulsatility index on the affected limb. Fourteen other patients had symmetric triphasic waveforms. We observed that the patients who had stage 1 reflex sympathetic dystrophy and warm limbs with durations of symptoms of more than 2 weeks had positive Doppler sonographic findings, whereas all patients with stage 2 reflex sympathetic dystrophy and all with normal skin temperature, regardless of stage, had normal waveforms. Doppler sonography revealed loss of normal triphasic arterial waveforms in some of the cases of stage 1 disease, whereas many cases of stage 1 disease and all cases of stage 2 disease had normal findings. Therefore, we think that Doppler sonography cannot be used for the diagnosis of reflex sympathetic dystrophy but may help in assessing hemodynamic stages of the disease.

  5. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  6. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  7. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  8. Residuation in orthomodular lattices

    Directory of Open Access Journals (Sweden)

    Chajda Ivan

    2017-04-01

    Full Text Available We show that every idempotent weakly divisible residuated lattice satisfying the double negation law can be transformed into an orthomodular lattice. The converse holds if adjointness is replaced by conditional adjointness. Moreover, we show that every positive right residuated lattice satisfying the double negation law and two further simple identities can be converted into an orthomodular lattice. In this case, also the converse statement is true and the corresponence is nearly one-to-one.

  9. The phase shifts leading to the broadening and shift of spectral lines

    Energy Technology Data Exchange (ETDEWEB)

    Roston, G.D. [Department of Physics, Faculty of Science, Alexandria University (Egypt)], E-mail: gamal_daniel@yahoo.com; Ghatass, Z.F. [Department of Environmental Studies, Institute of Graduate Studies and Research, Alexandria University (Egypt); Obaid, F.S. [Department of Mathematics, Faculty of Science, Qubba University (Libyan Arab Jamahiriya)

    2009-02-15

    The classical theory of collisional broadening and shift parameters ({beta}, {delta}) of an isolated spectral line was used to obtain simple analytical formulas for calculating both {beta} and {delta}. These formulas were obtained on the assumption that the short range interaction is effective only in the broadening while the long range is effective in the shift of the spectral line. These parameters {beta} and {delta} depend on the limiting phase shifts responsible for broadening {eta}{sub b} and shift {eta}{delta}. It was found that the values of {eta}{sub b} and {eta}{sub {delta}} are not equal to each other as was proposed by Weisskopf {eta}{sub b}={eta}{sub {delta}}=1. The maximum and average values of {eta}{sub b} ({eta}{sub bmax}, {eta}{sub bav}) and {eta}{sub {delta}} ({eta}{sub {delta}}{sub max}, {eta}{sub {delta}}{sub av}) were obtained by numerical evaluation, using different inverse power potentials. By introducing these parameters into the approximated formulas for {beta} and {delta} using Van der Waals and Lennard-Jones potential, it was found that the results of calculations for ({beta} and {delta}) with different atomic transitions perturbed by different inert gases are in close agreement with earlier results. Those results, obtained earlier, were based on the Lindholm-Foley theory especially with the average values of {eta}{sub b} [{eta}{sub bav}=0.6057] and the maximum values of {eta}{sub {delta}} [{eta}{sub {delta}}{sub max}=1.57625]. The impact parameters {rho}{sub b} and {rho}{sub {delta}} leading to the broadening and shift of the spectral line were also obtained for different interactions. It was found that the end parameter for the broadening {rho}{sub b} is not equal to the starting parameter for the shift {rho}{sub {delta}}.

  10. Ecocardiografia modo Doppler pulsado em gatos clinicamente sadios Pulsed wave Doppler echocardiography in clinically healthy cats

    OpenAIRE

    R.O. Carvalho; R.B. Araújo; E.F. Silva

    2006-01-01

    Estudou-se o fluxo sangüíneo através das quatro valvas cardíacas em 30 gatos clinicamente sadios, com idade entre um e cinco anos e peso médio de 4,08kg, por meio da ecocardiografia modo Doppler pulsado. Foram medidas a velocidade máxima e a velocidade média dos fluxos, e realizou-se uma análise qualitativa dos seus perfis. Os animais foram sedados pela combinação de quetamina (12mg/kg) e acepromazina (0,04mg/kg), aplicados por via intramuscular. Observou-se correlação positiva entre os parâm...

  11. Characterization of Hospital Residuals

    International Nuclear Information System (INIS)

    Blanco Meza, A.; Bonilla Jimenez, S.

    1997-01-01

    The main objective of this investigation is the characterization of the solid residuals. A description of the handling of the liquid and gassy waste generated in hospitals is also given, identifying the source where they originate. To achieve the proposed objective the work was divided in three stages: The first one was the planning and the coordination with each hospital center, in this way, to determine the schedule of gathering of the waste can be possible. In the second stage a fieldwork was made; it consisted in gathering the quantitative and qualitative information of the general state of the handling of residuals. In the third and last stage, the information previously obtained was organized to express the results as the production rate per day by bed, generation of solid residuals for sampled services, type of solid residuals and density of the same ones. With the obtained results, approaches are settled down to either determine design parameters for final disposition whether for incineration, trituration, sanitary filler or recycling of some materials, and storage politics of the solid residuals that allow to determine the gathering frequency. The study concludes that it is necessary to improve the conditions of the residuals handling in some aspects, to provide the cleaning personnel of the equipment for gathering disposition and of security, minimum to carry out this work efficiently, and to maintain a control of all the dangerous waste, like sharp or polluted materials. In this way, an appreciable reduction is guaranteed in the impact on the atmosphere. (Author) [es

  12. Ecocardiografia modo Doppler pulsado em gatos clinicamente sadios Pulsed wave Doppler echocardiography in clinically healthy cats

    Directory of Open Access Journals (Sweden)

    R.O. Carvalho

    2006-06-01

    Full Text Available Estudou-se o fluxo sangüíneo através das quatro valvas cardíacas em 30 gatos clinicamente sadios, com idade entre um e cinco anos e peso médio de 4,08kg, por meio da ecocardiografia modo Doppler pulsado. Foram medidas a velocidade máxima e a velocidade média dos fluxos, e realizou-se uma análise qualitativa dos seus perfis. Os animais foram sedados pela combinação de quetamina (12mg/kg e acepromazina (0,04mg/kg, aplicados por via intramuscular. Observou-se correlação positiva entre os parâmetros avaliados e a freqüência cardíaca, com exceção daqueles medidos no fluxo da valva aórtica. Não se observou correlação entre velocidades máxima e média e freqüência cardíaca e entre aquelas e peso corporal, e não houve diferença entre sexos.Pulsed wave Doppler echocardiography was used to study blood flow across the cardiac valves in 30 five-year-old cats (average body weight = 4.08kg. Animals were sedated using a combination of ketamin (12mg/kg, IM and acepromazin (0.04mg/kg, IM. Peak and mean velocities were determined, and blood flow patterns were recorded at the four cardiac valves. All variables, except those characterizing aortic valve flow, were positively correlated with heart rate. Blood flow variables were not correlated, however, with body weight; and there were no differences between males and females.

  13. Lorentz invariance and the rotor Doppler shift experiments

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1984-01-01

    It is shown that 'Rotor Doppler shift Experiments' provide a way to distinguish Einstein's Special Relativity (SR) from Lorentz's Aether Theory (LAT). Misconceptions in previous papers involving the Doppler shift experiments are examined. The theoretical and experimental data available on rotor Doppler shift experiments are analysed. Two models of SR violating theories are used to predict the output of a recently proposed experiment by Torr and Kolen. The first one corresponds to (strict) LAT and the other to an extended form of LAT Contrary to the first, the second theory leads to results in agreement with the preliminary experimental data of Torr et al indicating a breakdown both of SR and strict LAT. (Author) [pt

  14. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  15. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... and pharmacological pulmonary vasodilatation is established in normal subjects. The diagnostic and prognostic importance of adding tissue Doppler echocardiography to conventional echocardiographic and clinical parameters was evaluated in studies on patients with diseases associated with different modes of impact...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  16. Venstre ventrikels diastoliske funktion vurderet med transtorakal Doppler-ekkokardiografi

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Gøtzsche, O

    1996-01-01

    Left ventricular diastolic dysfunction is currently recognized in patients with different heart diseases. Three abnormal filling patterns of the left ventricle detected by pulsed-Doppler echocardiography are observed in patients with heart disease. Each filling pattern is characterised by different...... symptoms, and by differences in function and dimension of the left atrium and filling pressures. Mitral and pulmonary venous flow velocities and durations obtained by pulsed Doppler technique can be used to evaluate left ventricular diastolic function in patients with different heart diseases. However......, several factors affect the transmitral and pulmonary venous flow such as age, heart rate, positioning of the sample volume and aortic- and mitral valve insufficiency. These factors must be taken into consideration when the diastolic function is evaluated by pulsed Doppler technique....

  17. Classification of transcranial Doppler signals using artificial neural network.

    Science.gov (United States)

    Serhatlioğlu, Selami; Hardalaç, Firat; Güler, Inan

    2003-04-01

    Transcranial Doppler signals, recorded from the temporal region of brain on 110 patients were transferred to a personal computer by using a 16-bit sound card. The fast Fourier transform (FFT) method was applied to the recorded signal from each patient. Since FFT method inherently can not offer a good spectral resolution at jet blood flows, it sometimes causes wrong interpretation of transcranial Doppler signals. To do a correct and rapid diagnosis, transcranial Doppler blood flow signals were statistically arranged so that they were classified in artificial neural network. Back propagation neural network and self-organization map algorithms of artificial neural network were used for training, whereas momentum and delta-bar-delta algorithms were used for learning. The results of these algorithms were compared in the case of classification and learning.

  18. Pulsed and Color Doppler Sonographic Findings of Penile Mondor' Disease

    International Nuclear Information System (INIS)

    Han, Hye Yeon; Chung, Dong Jin; Kim, Kum Won; Hwang, Cheol Mog

    2008-01-01

    Penile Mondor's disease is a rare disease that's characterized by thrombosis in the dorsal vein of the penis. Doppler ultrasonography (US) clearly visualizes dorsal vein thrombosis and the associated hemodynamic alterations. Previous studies have demonstrated the typical color Doppler US findings of superficial dorsal vein thrombosis without the flow signals in this area, yet this is insufficient to understand the hemodynamics in penile Mondor's disease. We report here for the first time a cavernosal artery flow signal pattern in a penile Mondor's disease patient, in addition to its previously reported classic US findings. In conclusion, the Doppler US findings of thrombus without blood flow in the superficial dorsal vein and the low-flow, high resistance in the cavernosal artery may be suggestive of penile Mondor's disease

  19. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  20. Doppler term in the galaxy two-point correlation function: Wide-angle, velocity, Doppler lensing and cosmic acceleration effects

    Science.gov (United States)

    Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.

    2018-03-01

    We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys, however, we show that the Doppler term must be included. The effect of these terms is dominated by the magnification due to relativistic aberration effects and the slope of the galaxy redshift distribution and it generally mimics the effect of the local type primordial non-Gaussianity with the effective nonlinearity parameter fNLeff of a few; we show that this would affect forecasts on measurements of fNL at low-redshift. Our results show that a survey at low redshift with large number density over a wide area of the sky could detect the Doppler term with a signal-to-noise ratio of ∼ 1 - 20, depending on survey specifications.

  1. Improvements to the ion Doppler spectrometer diagnostic on the HIT-SI experiments

    Science.gov (United States)

    Hossack, Aaron; Chandra, Rian; Everson, Chris; Jarboe, Tom

    2018-03-01

    An ion Doppler spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record of 6.9 μs temporal and ≤2.8 cm spatial resolution in the midplane of each device. These allow Ciii and Oii flow, displacement, and temperature profiles to be observed simultaneously. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to a video camera, frame rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper half of the midplane. In HIT-SI3, frame rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from ≲13 to ≲5 eV (with an instrument temperature of 8-16 eV) and uncertainty in velocity from ≲2 to ≲1 km/s. Doppler shift and broadening are calculated via the Levenberg-Marquardt algorithm, after which the errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for Ciii peaked near the inboard current separatrix at ≈40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at ≈6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

  2. Diagnostic value of appendicular Doppler ultrasonography in acute appendicitis.

    Science.gov (United States)

    Uzunosmanoğlu, Hüseyin; Çevik, Yunsur; Çorbacıoğlu, Şeref Kerem; Akıncı, Emine; Buluş, Hakan; Ağladıoğlu, Kadir

    2017-05-01

    Acute appendicitis is one of the most common causes of acute abdominal pain prompting emergency department (ED) visits. It is critical for the physicians to promptly and accurately diagnose acute appendicitis. The present study aimed to evaluate the diagnostic efficacy of Doppler ultrasonography (USG) in patients with acute appendicitis and compare this new method with other commonly used radio-diagnostic tools. All patients who were diagnosed with acute appendicitis at the Kecioren Training and Research Hospital ED and later underwent appendectomy between October 2012 and April 2013 were included in the study. Approval from the ethics committee was obtained for this prospective study. The patients' demographic information, physical examination findings, vital signs, Alvarado scores, and laboratory and radiological exam results were recorded. A total of 60 patients were enrolled in the study. In 46 of the 60 patients, diagnosis of acute appendicitis was confirmed by histopathology results, whereas 14 patients, diagnoses was not confirmed by lab tests. Doppler USG could detect 43 of the 46 patients as true positives, and it detected 2 of the 14 patients with negative lab results as false positives. For diagnosis of acute appendicitis, sensitivity of appendicular Doppler USG was 93%, specificity was 85%, accuracy was 91%, positive likelihood ratio was 6.5, and negative likelihood ratio was 0.08. Doppler imaging can offer a high level of diagnostic success in patients with acute appendicitis. Appendicular Doppler USG offers a rapid and easy application without the need to expose patients to contrast medium and is superior to both USG and computed tomography. Therefore, we recommend the use of appendicular Doppler imaging as the primary radiological exam in diagnosing acute appendicitis.

  3. Spectral Doppler ultrasound of peripheral arteries: a pictorial review.

    Science.gov (United States)

    Nuffer, Zachary; Rupasov, Andrey; Bekal, Neel; Murtha, Jacqueline; Bhatt, Shweta

    This article reviews the pathophysiology and sonographic findings of peripheral arterial lesions, with emphasis on the spectral Doppler waveforms encountered in each. It discusses the characteristic features of the Doppler spectra in obstructive conditions, including thromboembolism, atherosclerotic disease, bypass graft occlusion, dissection, trauma, and compartment syndrome, as well as non-obstructive conditions, including hyperemia, pseudoaneurysm, and arteriovenous fistula. Familiarity with the commonly-encountered spectral waveforms in the setting of these lesions is necessary for timely and accurate diagnosis and treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Imaging doppler lidar for wind turbine wake profiling

    Science.gov (United States)

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  5. Spectral fine structure effects on material and doppler reactivity worth

    International Nuclear Information System (INIS)

    Greenspan, E.; Karni, Y.

    1975-01-01

    New formulations concerning the fine structure effects on the reactivity worth of resonances are developed and conclusions are derived following the extension to more general types of perturbations which include: the removal of resonance material at finite temperatures and the temperature variation of part of the resonance material. It is concluded that the flux method can overpredict the reactivity worth of resonance materials more than anticipated. Calculations on the Doppler worth were carried out; the results can be useful for asessing the contribution of the fine structure effects to the large discrepancy that exists between the calculated and measured small sample Doppler worths. (B.G.)

  6. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  7. Aerial ultrasonic micro Doppler sonar detection range in outdoor environments.

    Science.gov (United States)

    Bradley, Marshall; Sabatier, James M

    2012-03-01

    Current research demonstrates that micro Doppler sonar has the capability to uniquely identify the presence of a moving human, making it an attractive component in surveillance systems for border security applications. Primary environmental factors that limit sonar performance are two-way spreading losses, ultrasonic absorption, and backscattered energy from the ground that appears at zero Doppler shift in the sonar signal processor. Spectral leakage from the backscatter component has a significant effect on sonar performance for slow moving targets. Sonar performance is shown to rapidly decay as the sensor is moved closer to the ground due to increasing surface backscatter levels. © 2012 Acoustical Society of America

  8. Cerebral ischemia: magnetic resonance angiography and transcranial Doppler evaluation.

    Science.gov (United States)

    D'Aprile, P; Federico, F; Medicamento, N; Conte, C; Carella, A

    1994-02-01

    We examined 21 patients with ischemic cerebrovascular disease using magnetic resonance angiography and transcranial Doppler. In 17 patients (81%), the results obtained by the two methods were concordant. In our opinion, the associated use of transcranial Doppler and magnetic resonance angiography provides an accurate diagnostic evaluation of ischemic stroke patients, not only allowing the site of possible steno-occlusive disease of large and medium cerebral vessels to be identified, but also offering the possibility of obtaining dynamic information concerning the direction of blood flow in the presence of compensatory circulations at the level of Willis' circle.

  9. Photodetachment and Doppler laser cooling of anionic molecules

    Science.gov (United States)

    Gerber, Sebastian; Fesel, Julian; Doser, Michael; Comparat, Daniel

    2018-02-01

    We propose to extend laser-cooling techniques, so far only achieved for neutral molecules, to molecular anions. A detailed computational study is performed for {{{C}}}2- molecules stored in Penning traps using GPU based Monte Carlo simulations. Two cooling schemes—Doppler laser cooling and photodetachment cooling—are investigated. The sympathetic cooling of antiprotons is studied for the Doppler cooling scheme, where it is shown that cooling of antiprotons to subKelvin temperatures could becomes feasible, with impacts on the field of antimatter physics. The presented cooling schemes also have applications for the generation of cold, negatively charged particle sources and for the sympathetic cooling of other molecular anions.

  10. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Bo Yun; Lee, Jae Young; Chu, A Jung; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-01-15

    The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.

  11. Management of NORM Residues

    International Nuclear Information System (INIS)

    2013-06-01

    The IAEA attaches great importance to the dissemination of information that can assist Member States in the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support the nuclear fuel cycle and nuclear applications, and that address the legacy of past practices and accidents. However, radioactive residues are found not only in nuclear fuel cycle activities, but also in a range of other industrial activities, including: - Mining and milling of metalliferous and non-metallic ores; - Production of non-nuclear fuels, including coal, oil and gas; - Extraction and purification of water (e.g. in the generation of geothermal energy, as drinking and industrial process water; in paper and pulp manufacturing processes); - Production of industrial minerals, including phosphate, clay and building materials; - Use of radionuclides, such as thorium, for properties other than their radioactivity. Naturally occurring radioactive material (NORM) may lead to exposures at some stage of these processes and in the use or reuse of products, residues or wastes. Several IAEA publications address NORM issues with a special focus on some of the more relevant industrial operations. This publication attempts to provide guidance on managing residues arising from different NORM type industries, and on pertinent residue management strategies and technologies, to help Member States gain perspectives on the management of NORM residues

  12. [Quantitative Analysis of Power Doppler Images in Lateral Humeral Enthesopathy].

    Science.gov (United States)

    Walder, P; Paša, L; Pavliska, L

    2016-01-01

    PURPOSE OF THE STUDY The evaluation of efficiency of power Doppler sonography in the diagnosis of lateral humeral enthesopathy, role of correct assessment of Doppler sonographic images with the method of quantitative analysis, assessment of statistical differences between a group of patients with lateral humeral enthesopathy and a control group of healthy subjects and assessment of the diagnostic power of this test. In addition, consideration of the relevance of each area of the lateral compartment for assessment and diagnosis making in lateral humeral enthesopathy. MATERIAL AND METHODS A total of 41 subjects, aged 18 to 60 years, entered the study. Thirteen patients were diagnosed with lateral humeral enthesopathy on the basis of clinical tests and a positive reaction of the lateral humeral epicondylus to administration of local anaesthetic. The control group consisted of 28 subjects without clinical signs of lateral humeral enthesopathy and subjective complaints. Power Doppler activity was evaluated in the whole region studied and in sub-regions involving the enthesis of the common extensor tendon and the periosteum of the lateral epicondyle with the area distal to it. The evaluation was based on calculating the overall surface with power Doppler activity using the method of quantitative image analysis. Each patient was measured on three occasions and the median of values obtained was used in calculation. To assess the diagnostic power of this test, all values obtained from the whole power Doppler region measured were used. The optimal dividing criterion at which the method had a maximum of sensitivity and specificity was determined. RESULTS The most evident, statistically significant difference between the patient and the control group was recorded in the whole "Range of Interest" (ROI) region (p=1.34x10-6). A significant difference was also found in sub-regions corresponding chiefly to the tendon of the extensor carpi radialis brevis muscle and to the

  13. Double-resonance optical-pumping effect and ladder-type electromagnetically induced transparency signal without Doppler background in cesium atomic vapour cell

    International Nuclear Information System (INIS)

    Yang Bao-Dong; Gao Jing; Liang Qiang-Bing; Wang Jie; Zhang Tian-Cai; Wang Jun-Min

    2011-01-01

    In a Doppler-broadened ladder-type cesium atomic system (6S 1/2 -6P 3/2 -8S 1/2 ), this paper characterizes electromagnetically induced transparency (EIT) in two different experimental arrangements, and investigates the influence of the double-resonance optical-pumping (DROP) effect on EIT in both arrangements. When the probe laser is weak, DROP is explicitly suppressed. When the probe laser is moderate, population of the intermediate level (6P 3/2 F' = 5) is remarkable, therefore DROP is mixed with EIT. An interesting bimodal spectrum with the broad component due to DROP and the narrow part due to EIT has been clearly observed in cesium 6S 1/2 F = 4−6P 3/2 F' = 5−8S 1/2 F″ = 4 transitions. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Blood and Wall Signal Simulator for Doppler Ultrasound Signal Analysis Algorithm Development

    National Research Council Canada - National Science Library

    Fish, P

    2001-01-01

    Doppler ultrasound instruments, used for the detection and monitoring of vascular disease, require a means of separating the large, low frequency Doppler signal from the vessel wall from the signal...

  15. GPM Ground Validation NASA S-Band Dual Polarimetric (NPOL) Doppler Radar OLYMPEX V2

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation NASA S-Band Dual Polarimetric (NPOL) Doppler Radar OLYMPEX V2 dataset consists of rain rate, reflectivity, Doppler velocity, and other...

  16. Correlation between Doppler flow patterns in growth-restricted fetuses and neonatal circulation

    NARCIS (Netherlands)

    Tanis, J. C.; Boelen, M. R.; Schmitz, D. M.; Casarella, L.; van der Laan, M. E.; Bos, A. F.; Bilardo, C. M.

    Objectives To investigate whether prenatal Doppler parameters in growth-restricted fetuses are correlated with neonatal circulatory changes. Methods In 43 cases of suspected fetal growth restriction (FGR), serial Doppler measurements of umbilical artery (UA) and middle cerebral artery (MCA)

  17. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  18. Investigation of the chemical vicinity of defects in Mg and AZ31 with positron coincident Doppler boarding spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Martin

    2008-03-10

    Within the scope of the present work, two main goals have been achieved: Firstly, the coincident Doppler broadening spectrometer (CDBS) at the high intense positron source NEPOMUC has been elaborately improved in order to increase the spatial resolution for defect mapping measurements and to investigate samples with shallow positron trapping sites which are present e. g. in magnesium. Secondly, as an application, the chemical vicinity of defects in the industrially used magnesium based alloy AZ31 has been examined by means of the detailed investigation of ion-irradiated specimen with positron annihilation spectroscopy. Detailed simulations with the finite-element simulation tool COMSOL were used to optimize the focal diameter of the positron beam at the sample position in order to increase the spatial resolution. With a value of 0.3 mm, sub-mm resolution has now been reached. The CDBS has been furthermore equipped with a sample cooling unit in order to reach liquid nitrogen temperature, maintaining the feature of scanning the sample for defect mapping. Defects and their chemical surrounding in ion irradiated magnesium and the magnesium based alloy AZ31 were then investigated on an atomic scale with the CDBS. In the respective spectra the chemical information and the defect contribution have been thoroughly separated. For this purpose, samples of annealed Mg were irradiated with Mg-ions in order to create exclusively defects. In addition Al- and Zn-ion irradiations on Mg-samples were performed in order to create samples with both defects and impurity atoms. The ion irradiated area on the samples was investigated with laterally and depth resolved positron Doppler broadening spectroscopy (DBS) and compared with SRIM-simulations of the vacancy distribution. The investigation of the chemical vicinity of crystal defects in AZ31 was performed with CDBS on Mg-ion irradiated AZ31 with Mg-ion irradiated Mg. The outer tail of the energy distribution in the annihilation

  19. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation

    Science.gov (United States)

    Rink, Cameron L.; Wernke, Matthew M.; Powell, Heather M.; Tornero, Mark; Gnyawali, Surya C.; Schroeder, Ryan M.; Kim, Jayne Y.; Denune, Jeffrey A.; Albury, Alexander W.; Gordillo, Gayle M.; Colvin, James M.; Sen, Chandan K.

    2017-01-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial (n = 5) and transfemoral (n = 5) amputation were compared to able-limb controls (n = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function. PMID:28736682

  20. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation.

    Science.gov (United States)

    Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K

    2017-07-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n  = 5) and transfemoral ( n  = 5) amputation were compared to able-limb controls ( n  = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.

  1. Red Shift and Broadening of Backward Harmonic Radiation from Electron Oscillations Driven by Femtosecond Laser Pulse

    International Nuclear Information System (INIS)

    Tian Youwei; Yu Wei; Lu Peixiang; Senecha, Vinod K; Han, Xu; Deng Degang; Li Ruxin; Xu Zhizhan

    2006-01-01

    The characteristics of backward harmonic radiation due to electron oscillations driven by a linearly polarized fs laser pulse are analysed considering a single electron model. The spectral distributions of the electron's backward harmonic radiation are investigated in detail for different parameters of the driver laser pulse. Higher order harmonic radiations are possible for a sufficiently intense driving laser pulse. We have shown that for a realistic pulsed photon beam, the spectrum of the radiation is red shifted as well as broadened because of changes in the longitudinal velocity of the electrons during the laser pulse. These effects are more pronounced at higher laser intensities giving rise to higher order harmonics that eventually leads to a continuous spectrum. Numerical simulations have further shown that by increasing the laser pulse width the broadening of the high harmonic radiations can be controlled

  2. Optical bistability in the oscillation of an inhomogeneously broadened quasi-three-level laser

    International Nuclear Information System (INIS)

    Liu, Junhai; Tian, Xueping

    2013-01-01

    A theoretical modeling analysis is presented to study the optical bistability exhibited in the oscillation of an inhomogeneously broadened quasi-three-level laser. All the major characteristics of optical bistability depend on two normalized parameters, f and x a , which are defined by f = I sat,a /I sat,m and x a = 2α a0 p a /δ and are related to measurable properties of the laser medium. In comparison with the case of a homogeneously broadened laser, the essential condition for the occurrence of such bistability, f a /(x a + 1), turns out to be the same, whereas the intensities at the up- and down-thresholds are substantially increased and the bistability range is reduced. (paper)

  3. Broadening participation in Natural Sciences and Mathematics at the University of Maryland Baltimore County

    Science.gov (United States)

    Rous, Philip

    2013-03-01

    Over the past two decades, UMBC has undertaken a series of efforts to broaden participation in the natural sciences and mathematics, beginning with the establishment of the Meyerhoff program. Using as examples the multiple initiatives that followed, and with a focus on the challenge of increasing access and success of all students who enter as both freshmen and transfer students, I will describe a model of culture change that we have employed repeatedly to understand and guide our efforts in broadening participation. Particular attention will be paid to the concept of cultural capital, the role of innovators and the challenge of scaling small-scale innovations towards institutional change. Supported by the National Science Foundation and the Bill and Melinda Gates Foundation.

  4. Pressure broadening measurement of submillimeter-wave lines of O3

    International Nuclear Information System (INIS)

    Yamada, M.M.; Amano, T.

    2005-01-01

    The pressure broadening coefficients and their temperature dependences for two submillimeter-wave transitions of ozone, one being monitored with Odin and the other to be monitored with JEM/SMILES and EOS-MLS, have been determined by using a BWO based submillimeter-wave spectrometer. The measurements have also been extended to one of the symmetric isotopic species, 16 O 18 O 16 O. The isotopic species is observed in natural abundance and as a consequence the temperature dependence is not determined due to weak signal intensity. The pressure broadening parameters are determined with better than 1% accuracy, while the temperature dependence exponents are obtained within 1.5-3% accuracy for the normal species transitions

  5. From discrete to continuous the broadening of number concepts in early modern England

    CERN Document Server

    Neal, Katherine

    2002-01-01

    In the early modern period, a crucial transformation occurred in the classical conception of number and magnitude. Traditionally, numbers were merely collections of discrete units that measured some multiple. Magnitude, on the other hand, was usually described as being continuous, or being divisible into parts that are infinitely divisible. This traditional idea of discrete number versus continuous magnitude was challenged in the early modern period in several ways. This detailed study explores how the development of algebraic symbolism, logarithms, and the growing practical demands for an expanded number concept all contributed to a broadening of the number concept in early modern England. An interest in solving practical problems was not, in itself, enough to cause a generalisation of the number concept. It was the combined impact of novel practical applications together with the concomitant development of such mathematical advances as algebraic notation and logarithms that produced a broadened number conce...

  6. In-medium jet evolution: interplay between broadening and decoherence effects

    CERN Document Server

    Apolinário, Liliana; Milhano, Guilherme; Salgado, Carlos A.

    2016-01-01

    The description of the modifications of the coherence pattern in a parton shower, in the presence of a QGP, has been actively addressed in recent studies. Among the several achievements, finite energy corrections, transverse momentum broadening due to medium interactions and interference effects between successive emissions have been extensively improved as they seem to be essential features for a correct description of the results obtained in heavy-ion collisions. In this work, based on the insights of our previous work [1], we explore the physical interplay between broadening and decoherence, by generalising previous studies of medium-modifications of the antenna spectrum [2, 3, 4] - so far restricted to the case where transverse motion is neglected. The result allow us to identify two quantities controlling the decoherence of a medium modified shower that can be used as building blocks for a successful future generation of jet quenching Monte Carlo simulators: a generalisation of the $\\Delta_{med}$ paramet...

  7. Broadening of Plasmonic Resonance Due to Electron Collisions with Nanoparticle Boundary: а Quantum Mechanical Consideration

    DEFF Research Database (Denmark)

    Uskov, Alexander; Protsenko, Igor E.; Mortensen, N. Asger

    2014-01-01

    wavelength in the metal. The approach can be used in studies of plasmonic properties of both single nanoparticles and arrays of nanoparticles. Energy conservation is insured by a self-consistent solution of Maxwell's equations and our model for the photon absorption at the metal boundaries. Consequences......We present a quantum mechanical approach to calculate broadening of plasmonic resonances in metallic nanostructures due to collisions of electrons with the surface of the structure. The approach is applicable if the characteristic size of the structure is much larger than the de Broglie electron...... of the model are illustrated for the case of spheroid nanoparticles, and results are in good agreement with earlier theories. In particular, we show that the boundary-collision broadening of the plasmonic resonance in spheroid nanoparticles can depend strongly on the polarization of the impinging light....

  8. Line broadening analysis of implosion core conditions at Z using argon K-shell spectroscopy

    International Nuclear Information System (INIS)

    Burris-Mog, T.J.; Mancini, R.C.; Bailey, J.E.; Chandler, G.A.; Rochau, G.; Dunham, G.; Lake, P.W.; Peterson, K.; Slutz, S.A.; Mehlhorn, T.A.; Golovkin, I.E.; MacFarlane, J.J.

    2006-01-01

    We report on spectral line broadening analysis of Ar K-shell lines from argon-doped implosion cores driven by a dynamic hohlraum z-pinch. The observed Ar spectra include emissions from the resonance series in H- and He-like Ar ions, i.e., Lyα, Lyβ and Lyγ, and Heα, Heβ, Heγ and Heδ lines, respectively. The analysis accounts for opacity and Stark broadening to determine electron density, N e , and areal-density, NΔR, values for the ground state populations of H- and He-like Ar ions. Furthermore, these results are combined with the ratio of H- and He-like ground state populations to extract the electron temperature, T e

  9. Resonant Magnetization Tunneling in Molecular Magnets: Where is the Inhomogeneous Broadening?

    Science.gov (United States)

    Friedman, Jonathan R.; Sarachik, M. P.

    1998-03-01

    Since the discovery(J. R. Friedman, et al., Phys. Rev. Lett. 76), 3830 (1996) of resonant magnetization tunneling in the molecular magnet Mn_12 there has been intense research into the underlying mechanism of tunneling. Most current theories( V. Dobrovitski and A. Zvezdin, Europhys. Lett. 38), 377 (1997); L. Gunther, Europhys. Lett. 39, 1 (1997); D Garanin and E. Chudnovsky, Phys. Rev. B 56, 11102 (1997). suggest that a local internal (hyperfine or dipole) field transverse to the easy magnetization axis induces tunneling. These theories predict a resonance width orders of magnitude smaller than that actually observed. This discrepancy is attributed to inhomogeneous broadening of the resonance by the random internal fields. We present a detailed study of the tunnel resonance lineshape and show that it is Lorentzian, suggesting it has a deeper physical origin. Since the hyperfine fields are believed to be comparable to the observed width, it is surprising that there is no Gaussian broadening.

  10. Spectral broadening in anatase titanium dioxide waveguides at telecommunication and near-visible wavelengths.

    Science.gov (United States)

    Evans, Christopher C; Shtyrkova, Katia; Bradley, Jonathan D B; Reshef, Orad; Ippen, Erich; Mazur, Eric

    2013-07-29

    We observe spectral broadening of femtosecond pulses in single-mode anatase-titanium dioxide (TiO(2)) waveguides at telecommunication and near-visible wavelengths (1565 and 794 nm). By fitting our data to nonlinear pulse propagation simulations, we quantify nonlinear optical parameters around 1565 nm. Our fitting yields a nonlinear refractive index of 0.16 × 10(-18) m(2)/W, no two-photon absorption, and stimulated Raman scattering from the 144 cm(-1) Raman line of anatase with a gain coefficient of 6.6 × 10(-12) m/W. Additionally, we report on asymmetric spectral broadening around 794 nm. The wide wavelength applicability and negligible two-photon absorption of TiO(2) make it a promising material for integrated photonics.

  11. Residual-stress measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ezeilo, A.N.; Webster, G.A. [Imperial College, London (United Kingdom); Webster, P.J. [Salford Univ. (United Kingdom)

    1997-04-01

    Because neutrons can penetrate distances of up to 50 mm in most engineering materials, this makes them unique for establishing residual-stress distributions non-destructively. D1A is particularly suited for through-surface measurements as it does not suffer from instrumental surface aberrations commonly found on multidetector instruments, while D20 is best for fast internal-strain scanning. Two examples for residual-stress measurements in a shot-peened material, and in a weld are presented to demonstrate the attractive features of both instruments. (author).

  12. Inhomogeneous broadening of PAC spectra with Vzz and η joint probability distribution functions

    International Nuclear Information System (INIS)

    Evenson, W. E.; Adams, M.; Bunker, A.; Hodges, J.; Matheson, P.; Park, T.; Stufflebeam, M.; Zacate, M. O.

    2013-01-01

    The perturbed angular correlation (PAC) spectrum, G 2 (t), is broadened by the presence of randomly distributed defects in crystals due to a distribution of electric field gradients (EFGs) experienced by probe nuclei. Heuristic approaches to fitting spectra that exhibit such inhomogeneous broadening (ihb) consider only the distribution of EFG magnitudes V zz , but the physical effect actually depends on the joint probability distribution function (pdf) of V zz and EFG asymmetry parameter η. The difficulty in determining the joint pdf leads us to more appropriate representations of the EFG coordinates, and to express the joint pdf as the product of two approximately independent pdfs describing each coordinate separately. We have pursued this case in detail using as an initial illustration of the method a simple point defect model with nuclear spin I = 5/2 in several cubic lattices, where G 2 (t) is primarily induced by a defect trapped in the first neighbor shell of a probe and broadening is due to defects distributed at random outside the first neighbor shell. Effects such as lattice relaxation are ignored in this simple test of the method. The simplicity of our model is suitable for gaining insight into ihb with more than V zz alone. We simulate ihb in this simple case by averaging the net EFGs of 20,000 random defect arrangements, resulting in a broadened average G 2 (t). The 20,000 random cases provide a distribution of EFG components which are first transformed to Czjzek coordinates and then further into the full Czjzek half plane by conformal mapping. The topology of this transformed space yields an approximately separable joint pdf for the EFG components. We then fit the nearly independent pdfs and reconstruct G 2 (t) as a function of defect concentration. We report results for distributions of defects on simple cubic, face-centered cubic, and body-centered cubic lattices. The method explored here for analyzing ihb is applicable to more realistic cases.

  13. Inhomogeneous broadening of PAC spectra with V zz and η joint probability distribution functions

    Science.gov (United States)

    Evenson, W. E.; Adams, M.; Bunker, A.; Hodges, J.; Matheson, P.; Park, T.; Stufflebeam, M.; Zacate, M. O.

    2013-05-01

    The perturbed angular correlation (PAC) spectrum, G 2( t), is broadened by the presence of randomly distributed defects in crystals due to a distribution of electric field gradients (EFGs) experienced by probe nuclei. Heuristic approaches to fitting spectra that exhibit such inhomogeneous broadening (ihb) consider only the distribution of EFG magnitudes V zz , but the physical effect actually depends on the joint probability distribution function (pdf) of V zz and EFG asymmetry parameter η. The difficulty in determining the joint pdf leads us to more appropriate representations of the EFG coordinates, and to express the joint pdf as the product of two approximately independent pdfs describing each coordinate separately. We have pursued this case in detail using as an initial illustration of the method a simple point defect model with nuclear spin I = 5/2 in several cubic lattices, where G 2( t) is primarily induced by a defect trapped in the first neighbor shell of a probe and broadening is due to defects distributed at random outside the first neighbor shell. Effects such as lattice relaxation are ignored in this simple test of the method. The simplicity of our model is suitable for gaining insight into ihb with more than V zz alone. We simulate ihb in this simple case by averaging the net EFGs of 20,000 random defect arrangements, resulting in a broadened average G 2( t). The 20,000 random cases provide a distribution of EFG components which are first transformed to Czjzek coordinates and then further into the full Czjzek half plane by conformal mapping. The topology of this transformed space yields an approximately separable joint pdf for the EFG components. We then fit the nearly independent pdfs and reconstruct G 2( t) as a function of defect concentration. We report results for distributions of defects on simple cubic, face-centered cubic, and body-centered cubic lattices. The method explored here for analyzing ihb is applicable to more realistic cases.

  14. Line positions, intensities and self-broadening coefficients for the ν5 band of methyl chloride

    International Nuclear Information System (INIS)

    Barbouchi Ramchani, A.; Jacquemart, D.; Dhib, M.; Aroui, H.

    2013-01-01

    High resolution Fourier transform spectra have been recorded around 6.9 μm at room temperature using a rapid scan Bruker IFS 120 HR interferometer (unapodized Bruker resolution=0.005 cm −1 ). Transitions of both 12 CH 3 35 Cl and 12 CH 3 37 Cl isotopologues belonging to the ν 5 perpendicular band have been studied. Line positions, intensities, and self-broadening coefficients have been retrieved using a multispectrum fitting procedure that allowed to fit simultaneously the whole set of experimental spectra recorded at various pressures of CH 3 Cl. The wavenumber calibration has been performed using the frequencies of CO 2 transitions. The transition dipole moments squared have been determined for each measured line and the whole set of measurements has been compared with previous measurements and with values from HITRAN and GEISA databases. The rotational J and K dependencies of the self-broadening coefficients have been clearly observed and modeled using empirical polynomial expansions. The average accuracy of the line parameters obtained in this work has been estimated to be between 0.1×10 −3 and 1×10 −3 cm −1 for line positions, between 2% and 5% for line intensities and between 5% and 10% for self-broadening coefficients depending on the transitions. -- Highlights: ► Fourier-transform spectra of the ν 5 band of CH 3 Cl at room temperature. ► Measurements of line positions, intensities and self-broadening coefficients. ► Analysis of the J- and K-rotational dependences of self-widths. ► Comparisons with literature

  15. GOLD (GEO Opportunities for Leadership in Diversity): Building capacity for broadening participation in the Geosciences

    Science.gov (United States)

    Jones, B.; Patino, L. C.; Rom, E. L.; Adams, A.

    2017-12-01

    The geosciences continue to lag other science, technology, engineering, and mathematics (STEM) disciplines in the engagement, recruitment and retention of traditionally underrepresented and underserved groups, requiring more focused and strategic efforts to address this problem. Prior investments made by the National Science Foundation (NSF) related to broadening participation in STEM have identified many effective strategies and model programs for engaging, recruiting, and retaining underrepresented students in the geosciences. These investments also have documented clearly the importance of committed, knowledgeable, and persistent leadership for making local progress in this area. Achieving diversity at larger and systemic scales requires a network of diversity "champions" who can catalyze widespread adoption of these evidence-based best practices and resources. Although many members of the geoscience community are committed to the ideals of broadening participation, the skills and competencies to achieve success must be developed. The NSF GEO Opportunities for Leadership in Diversity (GOLD) program was implemented in 2016, as a funding opportunity utilizing the Ideas Lab mechanism. Ideas Labs are intensive workshops focused on finding innovative solutions to grand challenge problems. The ultimate aim of this Ideas Lab, organized by the NSF Directorate for Geosciences (GEO), was to facilitate the design, pilot implementation, and evaluation of innovative professional development curricula that can unleash the potential of geoscientists with interests in broadening participation to become impactful leaders within the community. The expectation is that mixing geoscientists with experts in broadening participation research, behavioral change, social psychology, institutional change management, leadership development research, and pedagogies for professional development will not only engender fresh thinking and innovative approaches for preparing and empowering

  16. Music-induced positive mood broadens the scope of auditory attention

    OpenAIRE

    Putkinen, Vesa; Makkonen, Tommi; Eerola, Tuomas

    2017-01-01

    Abstract Previous studies indicate that positive mood broadens the scope of visual attention, which can manifest as heightened distractibility. We used event-related potentials (ERP) to investigate whether music-induced positive mood has comparable effects on selective attention in the auditory domain. Subjects listened to experimenter-selected happy, neutral or sad instrumental music and afterwards participated in a dichotic listening task. Distractor sounds in the unattended channel elicite...

  17. Polyester Culture: The U.S. Army’s Aversion to Broadening Assignments

    Science.gov (United States)

    2012-04-18

    the altar of personal success‖ and impatient with the perceived ―preoccupation with insignificant statistics.‖ Army Culture drifted from its reliable...Infantry/Armor General Officers served their first Joint assignment after brigade command (Figure 2). 15 Current statistics for Joint- qualified maneuver...their respective branch, but fails to define broadening assignments, let alone a logical assignment sequence. Consequently , officers become fixated

  18. On acceleration dependence of Doppler effect in light

    Indian Academy of Sciences (India)

    Doppler effect involves [1–3] a shift in the wavelength or the frequency of a wave when its source and the observer are in relative motion. As is well known [1–3], this effect is analysed, classically, for sound by using the. (Newtonian) law of addition of velocities. However, this law of addition of velocities was.

  19. A Prospective Study of Doppler Velocimetry in Pregnancy-induced ...

    African Journals Online (AJOL)

    Mubeen

    KEY WORDS: Doppler study, fetomaternal outcome, pregnancy-induced hypertension. INTRODUCTION. Pregnancy-induced hypertension (PIH) remains a great challenge to obstetricians. Impaired utero-placental blood flow in PIH may result in intrauterine growth restriction. (IUGR), placental abruption and intrauterine fetal ...

  20. Usefulness of Doppler Parameter in Patients with Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of)

    2012-08-15

    The purpose of this study is to assess the usefulness of Doppler parameters in transplanted kidney function. Doppler parameters, including resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured in the interlobar artery of 55 transplant recipients. Patients were grouped according to glomerular filtration rate (GFR): Group A (GFR < 30 ml / min / 1.73 m2, n = 27) and group B (GFR {>=}30 ml / min / 1.73 m2, n = 28). Doppler parameters were compared between groups and correlated with the GFR. GFR (40.1 {+-} 26.9) showed a significant negative correlation with RI (0.69{+-}.08) (p = .002, r = -.414). RI (0.72 vs. 0.67), PI (1.42 vs. 1.23), and EDV (10.5 vs. 15.3) differed significantly between groups (p < .05), however, PSV was not (36.9 vs. 47.1). Patients in group A (n = 11) with a lower RI than the mean had significantly lower PSV (31.7 vs. 45.1; p = .027) and EDV (11.1 vs. 16.7; p .017), compared with such patients in group B (n = 21). Doppler parameters are useful for evaluation of function of transplanted kidney. Even if the RI is normal, PSV and EDV may be used as hemodynamic indicators.

  1. Doppler Spectrum from Moving Scatterers in a Random Environment

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2009-01-01

    A random non-line-of-sight environment with stationary transmitter and receiver is considered. In such an environment movement of a scatterer will lead to perturbations of the otherwise static channel with a resulting Doppler spectrum. This is quite a general situation in outdoor environments...

  2. Coronary Flow Velocity Reserve Assessed by Transthoracic Doppler

    DEFF Research Database (Denmark)

    Michelsen, Marie M; Peña, Adam; Mygind, Naja D

    2016-01-01

    BACKGROUND: Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography is a noninvasive measure of microvascular function, but it has not achieved widespread use, mainly because of concerns of validity and feasibility. The aim of this study was to describe the feasib...

  3. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Carlos A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  4. Laser Doppler perfusion monitoring and imaging: novel approaches

    NARCIS (Netherlands)

    Humeau, Anne; Steenbergen, Wiendelt; Nilsson, Henrik; Strömberg, Tomas

    2007-01-01

    Laser Doppler flowmetry (LDF) is a non invasive method enabling the monitoring of microvascular blood flow, a very important marker of tissue health. This article gives an overview on the concept of LDF for microvascular perfusion monitoring and imaging. It first describes the theoretical background

  5. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    2013). The correlation between Doppler factor and the spectral index can be discussed using a bigger sample. The relativistic beaming effects are also discussed in this proceedings (Li et al. 2014; Wu et al. 2014; Nie et al. 2014). The effective spectral index αOX is anticorre- lated with the viewing angle, and claimed to be ...

  6. Augmented Reality Based Doppler Lidar Data Visualization: Promises and Challenges

    Directory of Open Access Journals (Sweden)

    Cherukuru N. W.

    2016-01-01

    As a proof of concept, we used the lidar data from a recent field campaign and developed a smartphone application to view the lidar scan in augmented reality. In this paper, we give a brief methodology of this feasibility study, present the challenges and promises of using AR technology in conjunction with Doppler wind lidars.

  7. Processor operated correlator with applications to laser Doppler signals

    DEFF Research Database (Denmark)

    Bisgaard, C.; Johnsen, B.; Hassager, Ole

    1984-01-01

    A 64-channel correlator is designed with application to the processing of laser Doppler anemometry signals in the range 200 Hz to 250 kHz. The correlator is processor operated to enable the consecutive sampling of 448 correlation functions at a rate up to 500 Hz. Software is described to identify...

  8. Measuring Velocity and Acceleration Using Doppler Shift of a ...

    Indian Academy of Sciences (India)

    . 1. Introduction ... Doppler effect demands that time is universal, and not relative. We emphasize then that, we do not ..... the material ejected by the prime mover at a later time and is being obstructed by material the jet is ramming into. Then, let ...

  9. Assessment of Uterine and Umbilical Arteries Doppler Indices in ...

    African Journals Online (AJOL)

    Pregnancy induced hypertension (PIH) is a major cause of maternal and perinatal morbidity and mortality in developing countries including Nigeria. Doppler velocimetric indices of the uterine and umbilical arteries may predict the impact of PIH on perfusion of the uteroplacental and fetoplacental circulations respectively.

  10. Passive emitter location with Doppler frequency and interferometric measurements

    NARCIS (Netherlands)

    Groot, J.S.; Dam, F.A.M.; Theil, A.

    2008-01-01

    Ground based emitters can be located with a receiver installed on an airborne platform. This paper discusses techniques based on Doppler frequency and differential phase measurements (interferometry). Measurements of the first technique are provided, while we discuss and compare the theoretical

  11. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    excluded from the study. Color Doppler was performed in all cases, followed by laparoscopy. Further, findings on laparoscopy were compared with those of CDUS. A 95% confidence interval for the sensitivity of CDUS was estimated considering a positive result on CDUS as the binomial variable. Results. Out of 25 patients, ...

  12. Radar Micro-Doppler classification of Mini-UAVs

    NARCIS (Netherlands)

    Harmanny, R.L.A.; Prémel-Cabic, G.; Wit, J.J.M.

    2015-01-01

    The radar micro-Doppler signature of a target depends on its micro-motion, i.e., the motion of parts of a target relative to the motion of the target as a whole. These micro-motions are very characteristic considering different target classes, e.g., the slow pendulum-like motion of a bird’s wings

  13. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; de Knegt, Martina Chantal

    2016-01-01

    PURPOSE: To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI) M-mode through the mitral valve (MV). Furthermore, to evaluate the association of the myocardial performance index (MPI) obtained by TDI M-mode (MPITDI) and the conventional method of obtaining...

  14. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    Background The ankle region is frequently involved in juvenile idiopathic arthritis (JIA) but difficult to examine clinically due to its anatomical complexity. The aim of the study was to evaluate the role of ultrasonography (US) of the ankle and midfoot (ankle region) in JIA. Doppler-US detected...

  15. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  16. Renal Doppler Indices in Children with Nephrotic Syndrome ...

    African Journals Online (AJOL)

    Summary: The resistive and pulsatility indices are known tools for assessing renal function in kidney diseases, especially in proteinuric conditions like Paediatric Nephrotic syndrome (NS) which is a glomerular disease. However, there is a limited knowledge in the use of Doppler Resistive and pulsatility indices in the ...

  17. Doppler Bubble Grades After Diving and Relevance of Body Fat

    NARCIS (Netherlands)

    Schellart, Nico A. M.; Vellinga, Tjeerd P. van Rees; Van Dijk, Frank J.; Sterk, Wouter

    2012-01-01

    SCHELLART NAM, VAN REES VELLINGA TP, VAN DIJK FJ, STERK W. Doppler bubble grades after diving and relevance of body fat. Aviat Space Environ Med 2012; 83:951-7. Background: From the literature on venous gas embolism (VGE) and decompression sickness (DCS), it remains unclear whether body fat is a

  18. Diagnostic sensitivity and specificity of Doppler ultrasound in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Terslev, L.; Recke, P. von der; Torp-Pedersen, S.

    2008-01-01

    Objective. To evaluate the sensitivity and specificity of Doppler ultrasound (DUS) in diagnosing arthritis in the wrist and hands, and, if possible, to define a cutoff level for our ultrasound measures for inflammation, resistive index (RI), and color fraction. Methods. Using DUS, 88 patients...

  19. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 months...

  20. Applications of doppler effect in navigation and oceanography

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The Doppler effect is the change in frequency of the received sound waves/electromagnetic waves when there is a relative motion between the transmitter and the receiver of these waves. This effect is used for diverse applications in different areas...

  1. Laser frequency stabilization and large detuning by Doppler-free ...

    Indian Academy of Sciences (India)

    We present results of a study of frequency stabilization of a diode laser ( = 780 nm) using the Doppler-free dichroic lock (DFDL) technique and its use for laser cooling of atoms. Quantitative measurements of frequency stability were performed and the Allan variance was found to be 6.9 × 10−11 for an averaging time of 10 ...

  2. Measuring Velocity and Acceleration Using Doppler Shift of a ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Abstract. We describe here as to how the Doppler shift of a source needs to be used to measure its velocity and acceleration. We also apply this method, as an example here, to spectral lines of the blue-shifted jet in micro-quasar SS433 and discuss the intricacies of these measurements.

  3. Comparison between a newly developed PC-based Doppler ...

    African Journals Online (AJOL)

    Objectives. To determine the accuracy of the resistance index (RI) of flow velocity waveforms of the umbilical artery measured using a newly developed PC-based continuous wave Doppler device (Umbiflow) with regard to systematic and random variations when compared with a commercial standard (Vasoflow). Design.

  4. Doppler Lidar in the Wind Forecast Improvement Projects

    Directory of Open Access Journals (Sweden)

    Pichugina Yelena

    2016-01-01

    Full Text Available This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.

  5. Fiber-based coherent pulsed Doppler lidar for atmospheric monitoring

    Science.gov (United States)

    Pearson, Guy N.; Eacock, Justin R.

    2002-01-01

    A pulsed Doppler lidar for short range atmospheric backscatter measurements has been developed using fiber- optic components. The system employs a MOPA architecture and operates at a wavelength of 1.548 micrometers in a short pulse, low pulse energy, high repetition rate mode with a 30 mm diameter monostatic aperture. Details of the design and performance are given.

  6. Comparision of doppler studies in obstetrics with foetal outcome ...

    African Journals Online (AJOL)

    Subjects: One hundread and twenty one consecutive female subjects, between 24 and 443 years of age, at or over 28 weeks gestation, referred to the Radiology Department of Aga Khan University Hospital for obstetric doppler ultrasonography. Main outcome measures: Foetal outcome was defined as poor by using either ...

  7. Laser frequency stabilization and large detuning by Doppler-free ...

    Indian Academy of Sciences (India)

    method for frequency stabilization of these lasers is based on saturated absorption spectroscopy (SAS) [3]. The laser frequency is locked either at the center or at the side of a narrow peak in the Doppler-free high-resolution saturated absorp- tion spectrum of the atom. Locking at the side of the peak is straightforward and.

  8. Value of dobutamine stress tissue Doppler in evaluation of LV ...

    African Journals Online (AJOL)

    Aim: To clarify the value of dobutamine stress tissue Doppler in the evaluation of LV functional improvement after elective PCI. Methods: The study included 60 patients with hibernating viable myocardium proved by DSE referred for an evaluation of myocardial viability prior to revascularization. Hemodynamic and ...

  9. A simplified study of trans-mitral Doppler patterns

    Directory of Open Access Journals (Sweden)

    Thomas George

    2008-11-01

    Full Text Available Abstract Background Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. Presentation of the hypothesis In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Testing the hypothesis Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Implications of the hypothesis Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  10. A simplified study of trans-mitral Doppler patterns.

    Science.gov (United States)

    Thomas, George

    2008-11-28

    Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  11. Transcranial Doppler for detection of cerebral ischaemia during carotid endarterectomy

    DEFF Research Database (Denmark)

    Jørgensen, L G; Schroeder, T V

    1992-01-01

    We evaluated transcranial Doppler sonography (TCD) for the detection of cerebral ischaemia during carotid endarterectomy in 30 male and 14 female patients with ipsilateral focal cerebro-vascular symptoms. Surgery was performed during halothane-nitrous oxide anaesthesia with moderate hypocapnia...

  12. A Prospective Study of Doppler Velocimetry in Pregnancy-induced ...

    African Journals Online (AJOL)

    Doppler studies were carried, and parameters recorded in uterine, umbilical and middle cerebral artery (MCA) were Systolic/Diastolic ratio, Resistance Index, Cerebro Placental Index (CPI). Fetal outcomes were monitored. Statistical analysis was performed using Epi InfoTM software (Version 3.5.1, CDC, Atlanta). Test for ...

  13. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    are more common than the broad absorption lines. (Richards 2001; Wild et al. 2008; Shen .... culated with the emission redshifts based on the broad Mg II centroid) were selected. 3. Distribution of Doppler redshifts .... absorption lines in quasar spectra seem to be very common (e.g., Nestor et al. 2008;. Hamann et al. 2011).

  14. Analysis of self-broadened pure rotational and rovibrational lines of methyl chloride at room temperature

    Science.gov (United States)

    Bray, C.; Jacquemart, D.; Lacome, N.; Guinet, M.; Cuisset, A.; Eliet, S.; Hindle, F.; Mouret, G.; Rohart, F.; Buldyreva, J.

    2013-02-01

    Rovibrational absorption spectra of methyl chloride in the spectral region between 2800 and 3200 cm-1 were recorded with a high-resolution Fourier transform spectrometer. A multispectrum fitting procedure was used to analyze 527 transitions of the ν1 band and to retrieve the self-broadening coefficients for various J- and K-values with an estimated accuracy around 8%. Pure rotational transitions of CH3Cl in the submillimeter/terahertz region (0.2-1.4 THz) were also investigated using two complementary techniques of frequency-multiplication and continuous-wave photomixing. Forty-three pure rotational self-broadening coefficients were extracted with the accuracy between 3 and 5%. The whole set of measured values was used to model the J- and K-rotational dependences of the self-broadening coefficients by second-order polynomials. In addition, semi-classical calculations were performed, based on the real symmetric-top geometry of the active molecule, an intermolecular potential model including not only the dominant electrostatic but also the short-range forces, as well as on an exact classical treatment of the relative translational motion of the colliding partners. Comparison of all experimental and theoretical results shows similar rotational dependences and no significant vibrational dependence, so that extrapolations to other spectral regions should be straightforward.

  15. Power-law temperature dependence of collision broadening and shift of atomic and molecular rovibronic lines

    International Nuclear Information System (INIS)

    Cybulski, Hubert; Bielski, Andrzej; Ciuryło, Roman; Szudy, Józef; Trawiński, Ryszard S.

    2013-01-01

    The classical phase-shift theory of spectral line shapes is used to examine various aspects of the applicability of the power-law relations to the description of temperature variations of pressure broadening and shifting coefficients of the isolated atomic and rovibronic molecular lines in a wide temperature range. Model calculations performed for potentials of the Lennard-Jones type indicate that the temperature dependence exponents of the broadening and shifting can be related to the details of the intermolecular interactions. It is shown that they are sensitive to the range of temperatures assumed in the fit and therefore extreme care must be taken when the power-law temperature dependence is used as a scaling law. The problems of the failure of the power-law and of variations in the sign of pressure shift coefficients with increasing temperature are discussed. Very good fits of Frost's empirical formula for temperature dependence of pressure shift to the theoretical ones are obtained. -- Highlights: ► Classical theory of line shapes is used to examine the power-law relations. ► The broadening and shifting exponents depend on the range of temperatures in the fit. ► Extreme care must be taken when using the power-law dependence as a scaling law

  16. Accounting for inhomogeneous broadening in nano-optics by electromagnetic modeling based on Monte Carlo methods

    Science.gov (United States)

    Gudjonson, Herman; Kats, Mikhail A.; Liu, Kun; Nie, Zhihong; Kumacheva, Eugenia; Capasso, Federico

    2014-01-01

    Many experimental systems consist of large ensembles of uncoupled or weakly interacting elements operating as a single whole; this is particularly the case for applications in nano-optics and plasmonics, including colloidal solutions, plasmonic or dielectric nanoparticles on a substrate, antenna arrays, and others. In such experiments, measurements of the optical spectra of ensembles will differ from measurements of the independent elements as a result of small variations from element to element (also known as polydispersity) even if these elements are designed to be identical. In particular, sharp spectral features arising from narrow-band resonances will tend to appear broader and can even be washed out completely. Here, we explore this effect of inhomogeneous broadening as it occurs in colloidal nanopolymers comprising self-assembled nanorod chains in solution. Using a technique combining finite-difference time-domain simulations and Monte Carlo sampling, we predict the inhomogeneously broadened optical spectra of these colloidal nanopolymers and observe significant qualitative differences compared with the unbroadened spectra. The approach combining an electromagnetic simulation technique with Monte Carlo sampling is widely applicable for quantifying the effects of inhomogeneous broadening in a variety of physical systems, including those with many degrees of freedom that are otherwise computationally intractable. PMID:24469797

  17. Predictable progressive Doppler deterioration in IUGR: does it really exist?

    LENUS (Irish Health Repository)

    Unterscheider, Julia

    2013-12-01

    An objective of the Prospective Observational Trial to Optimize Pediatric Health in IUGR (PORTO) study was to evaluate multivessel Doppler changes in a large cohort of intrauterine growth restriction (IUGR) fetuses to establish whether a predictable progressive sequence of Doppler deterioration exists and to correlate these Doppler findings with respective perinatal outcomes.

  18. Radar micro-Doppler of wind turbines : Simulation and analysis using rotating linear wire structures

    NARCIS (Netherlands)

    Krasnov, O.A.; Yarovoy, A.

    2015-01-01

    A simple electromagnetic model of wind-turbine's main structural elements as the linear wired structures is developed to simulate the temporal patterns of observed radar return Doppler spectra (micro-Doppler). Using the model, the micro-Doppler for different combinations of the turbines rotation

  19. Classification of Small UAVs and Birds by Micro-Doppler Signatures

    NARCIS (Netherlands)

    Molchanov, P.; Egiazarian, K.; Astola, J.; Harmanny, R.I.A.; Wit, J.J.M. de

    2013-01-01

    The problem of unmanned aerial vehicles classification using continuous wave radar is considered in this paper. Classification features are extracted from micro-Doppler signature. Before the classification, the micro-Doppler signature is filtered and aligned to compensate the Doppler shift caused by

  20. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously