WorldWideScience

Sample records for residential light fixtures

  1. 46 CFR 120.410 - Lighting fixtures.

    Science.gov (United States)

    2010-10-01

    ...) Each table lamp, desk lamp, floor lamp, or similar equipment must be secured in place so that it cannot... Fixtures,” UL 1571, “Incandescent Lighting Fixtures,” UL 1572, “High Intensity Discharge Lighting Fixtures...

  2. High Output LED-Based Profile Lighting Fixture

    DEFF Research Database (Denmark)

    Török, Lajos; Beczkowski, Szymon; Munk-Nielsen, Stig

    2011-01-01

    Recent developments in power light emitting diode (LED) industry have made LEDs suitable for being efficiently used in high intensity lighting fixtures instead of the commonly used high intensity discharge (HID) lamps. A high output LEDbased profile-light fixture is presented in this paper...

  3. Case study: Fixture water use and drinking water quality in a new residential green building.

    Science.gov (United States)

    Salehi, Maryam; Abouali, Mohammad; Wang, Mian; Zhou, Zhi; Nejadhashemi, Amir Pouyan; Mitchell, Jade; Caskey, Stephen; Whelton, Andrew J

    2018-03-01

    Residential plumbing is critical for the health and safety of populations worldwide. A case study was conducted to understand fixture water use, drinking water quality and their possible link, in a newly plumbed residential green building. Water use and water quality were monitored at four in-building locations from September 2015 through December 2015. Once the home was fully inhabited average water stagnation periods were shortest at the 2nd floor hot fixture (90 percentile of 0.6-1.2 h). The maximum water stagnation time was 72.0 h. Bacteria and organic carbon levels increased inside the plumbing system compared to the municipal tap water entering the building. A greater amount of bacteria was detected in hot water samples (6-74,002 gene copy number/mL) compared to cold water (2-597 gene copy number/mL). This suggested that hot water plumbing promoted greater microbial growth. The basement fixture brass needle valve may have caused maximum Zn (5.9 mg/L), Fe (4.1 mg/L), and Pb (23 μg/L) levels compared to other fixture water samples (Zn ≤ 2.1 mg/L, Fe ≤ 0.5 mg/L and Pb ≤ 8 μg/L). At the basement fixture, where the least amount of water use events occurred (cold: 60-105, hot: 21-69 event/month) compared to the other fixtures in the building (cold: 145-856, hot: 326-2230 event/month), greater organic carbon, bacteria, and heavy metal levels were detected. Different fixture use patterns resulted in disparate water quality within a single-family home. The greatest drinking water quality changes were detected at the least frequently used fixture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Universal fixture design for body mounted LED lights

    Science.gov (United States)

    Hajra, Debdyut

    2017-09-01

    Today LED headlamps, armbands and ankle-bands, shoe-lights etc. have become very popular. These find extensive use in search and rescue operations, mining, carving, etc. and are also used by individuals during hiking, trekking, running, etc. during dark hours. They serve two main purposes: they provide sufficient illumination in low light conditions and they are used to indicate the presence of a person after dark. These have the same basic requirements. They must produce sufficient light, have high durability, long battery life, must be light weight and energy efficient. This paper discusses possibilities of designing a universal LED fixture can be designed so that it meets the respective needs of everyone irrespective of their background and industry. It discusses the materials to be used for its different body parts, innovative clip design for attachment with support structures like head and armbands, helmets, shoes, etc.

  5. Evaluation of light-emitting diode beacon light fixtures.

    Science.gov (United States)

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  6. 24 CFR 3285.702 - Miscellaneous lights and fixtures.

    Science.gov (United States)

    2010-04-01

    ... installation instructions. (f) Testing. (1) After completion of all electrical wiring and connections... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and... canopy and the wiring outlet box. (d) Exterior lights. (1) The junction box covers must be removed and...

  7. Strategy Guideline: High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J.

    2012-02-01

    The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

  8. Chapter 6: Residential Lighting Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Dimetrosky, Scott [Apex Analytics LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics LLC, Boulder, CO (United States)

    2015-02-01

    In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

  9. Strategy Guideline. High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J. [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This report has been developed to provide a tool for the understanding and application of high performance lighting in the home. The strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner’s expectations for high quality lighting.

  10. Residential and Light Commercial HVAC. Teacher Edition.

    Science.gov (United States)

    Stephenson, David; Fulkerson, Dan, Ed.

    This curriculum guide contains 18 units of instruction for a competency-based course in residential and light commercial heating, ventilating, and air conditioning (HVAC). Introductory materials include a competency profile and an instructional/task analysis that correlates job training with related information for this course. Each instructional…

  11. Residential Lighting End-Use Consumption Study: Estimation Framework and Initial Estimates

    Energy Technology Data Exchange (ETDEWEB)

    Gifford, Will R.; Goldberg, Miriam L.; Tanimoto, Paulo M.; Celnicker, Dane R.; Poplawski, Michael E.

    2012-12-01

    The U.S. DOE Residential Lighting End-Use Consumption Study is an initiative of the U.S. Department of Energy’s (DOE’s) Solid-State Lighting Program that aims to improve the understanding of lighting energy usage in residential dwellings. The study has developed a regional estimation framework within a national sample design that allows for the estimation of lamp usage and energy consumption 1) nationally and by region of the United States, 2) by certain household characteristics, 3) by location within the home, 4) by certain lamp characteristics, and 5) by certain categorical cross-classifications (e.g., by dwelling type AND lamp type or fixture type AND control type).

  12. THE IMPLICATIONS OF THE ENVIRONMENTAL MARKETING FACTORS WITHIN THE LIGHTING SOURCES AND FIXTURES MARKET

    Directory of Open Access Journals (Sweden)

    Cornelia Denisa IVAN

    2014-10-01

    Full Text Available Every company functionality is influenced by the environment in which they operate. In the present economical environment, the enterprise cannot survive in a market based on competition without continuously struggling to keep informed about the surroundings. The aim of this paper is to identify at the right time the new opportunities of development and also the threats which may compromise the company’s results or, even worse, may put the company in a difficult position. This research is important for the development of the enterprise’s strategies. The analysis of the marketing environment varies according to the field of the enterprise’s activity. Therefore, this article is a case study that examines the influence of environmental factors on the lighting sources and fixtures market (LSF. The originality and quality of the case stem from the attempt to analyze a dynamic field characterized by the buyers’ change of preferences and their receptivity to what is new, which requires increased consideration for the influence of environmental factors. The challenges of analyzing this domain consist of the transformations that take place with the new lighting technologies proposed by manufacturers to meet the users’ preferences. This review is relevant to the LSF market, but it can also be extended to other related fields.

  13. Evaluation of light-emitting diode beacon light fixtures : final report.

    Science.gov (United States)

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  14. LED Context Lighting System in Residential Areas

    Directory of Open Access Journals (Sweden)

    Sook-Youn Kwon

    2014-01-01

    Full Text Available As issues of environment and energy draw keen interest around the globe due to such problems as global warming and the energy crisis, LED with high optical efficiency is brought to the fore as the next generation lighting. In addition, as the national income level gets higher and life expectancy is extended, interest in the enhancement of life quality is increasing. Accordingly, the trend of lightings is changing from mere adjustment of light intensity to system lighting in order to enhance the quality of one’s life as well as reduce energy consumption. Thus, this study aims to design LED context lighting system that automatically recognizes the location and acts of a user in residential areas and creates an appropriate lighting environment. The proposed system designed in this study includes three types of processing: first, the creation of a lighting environment index suitable for the user’s surroundings and lighting control scenarios and second, it measures and analyzes the optical characteristics that change depending on the dimming control of lighting and applies them to the index. Lastly, it adopts PIR, piezoelectric, and power sensor to grasp the location and acts of the user and create a lighting environment suitable for the current context.

  15. Light extraction enhancement from organic light-emitting diodes with randomly scattered surface fixture

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Dong-Ying; Shi, Xiao-Bo; Gao, Chun-Hong; Cai, Shi-Duan; Jin, Yue; Liao, Liang-Sheng, E-mail: lsliao@suda.edu.cn

    2014-09-30

    Graphical abstract: - Highlights: • A combination of scattering layer and roughened substrate is used for light extraction from OLEDs. • The scattering layer is readily achieved by spin-coating the TiO{sub 2} sol. • The enhancement relying scattering depends on the size of TiO{sub 2} nano particles. • With the light extraction techniques the uniform emission is achieved. - Abstract: A combination of a scattering medium layer and a roughened substrate was proposed to enhance the light extraction efficiency of organic light-emitting diodes (OLEDs). Comparing with a reference OLED without any scattering layer, 65% improvement in the forward emission has been achieved with a scattering layer formed on an intentionally roughened external substrate surface of the OLED by spin-coating a sol–gel fabricated matrix containing well dispersed titania (TiO{sub 2}) particles. Such a combination method not only demonstrated efficient extraction of the light trapped in the glass substrate but also achieved homogenous emission from the OLED panel. The proposed technique, convenient and inexpensive, is believed to be suitable for the large area OLED production in lighting applications.

  16. Emergency lighting for industrial, commercial and residential premises

    CERN Document Server

    Lyons, X

    2013-01-01

    Emergency Lighting: For Industrial, Commercial and Residential Premises concerns itself with the provision of emergency lighting to facilitate exit routes for people in industrial, commercial, and residential areas. The book covers important topics such as the objectives of emergency lighting systems; the identification of safe routes under low lighting in different areas; and related devices such as luminaires, emergency signs, and way-guidance. Also discussed are the applications of emergency lighting; factors to consider in the design of emergency lighting; electrical installations; and tes

  17. Transducer-Mounting Fixture

    Science.gov (United States)

    Spiegel, Kirk W.

    1990-01-01

    Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

  18. Graphite Composite Panel Polishing Fixture

    Science.gov (United States)

    Hagopian, John; Strojny, Carl; Budinoff, Jason

    2011-01-01

    The use of high-strength, lightweight composites for the fixture is the novel feature of this innovation. The main advantage is the light weight and high stiffness-to-mass ratio relative to aluminum. Meter-class optics require support during the grinding/polishing process with large tools. The use of aluminum as a polishing fixture is standard, with pitch providing a compliant layer to allow support without deformation. Unfortunately, with meter-scale optics, a meter-scale fixture weighs over 120 lb (.55 kg) and may distort the optics being fabricated by loading the mirror and/or tool used in fabrication. The use of composite structures that are lightweight yet stiff allows standard techniques to be used while providing for a decrease in fixture weight by almost 70 percent. Mounts classically used to support large mirrors during fabrication are especially heavy and difficult to handle. The mount must be especially stiff to avoid deformation during the optical fabrication process, where a very large and heavy lap often can distort the mount and optic being fabricated. If the optic is placed on top of the lapping tool, the weight of the optic and the fixture can distort the lap. Fixtures to support the mirror during fabrication are often very large plates of aluminum, often 2 in. (.5 cm) or more in thickness and weight upwards of 150 lb (68 kg). With the addition of a backing material such as pitch and the mirror itself, the assembly can often weigh over 250 lb (.113 kg) for a meter-class optic. This innovation is the use of a lightweight graphite panel with an aluminum honeycomb core for use as the polishing fixture. These materials have been used in the aerospace industry as structural members due to their light weight and high stiffness. The grinding polishing fixture consists of the graphite composite panel, fittings, and fixtures to allow interface to the polishing machine, and introduction of pitch buttons to support the optic under fabrication. In its

  19. Evaluation of advanced technologies for residential appliances and residential and commercial lighting

    Energy Technology Data Exchange (ETDEWEB)

    Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

    1995-01-01

    Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

  20. Fixture for winding transformers

    Science.gov (United States)

    Mclyman, M. T.

    1980-01-01

    Bench-mounted fixture assists operator in winding toroid-shaped transformer cores. Toroid is rigidly held in place as wires are looped around. Arrangement frees both hands for rapid winding and untangling of wires that occurs when core is hand held.

  1. Samus Toroid Installation Fixture

    Energy Technology Data Exchange (ETDEWEB)

    Stredde, H.; /Fermilab

    1990-06-27

    The SAMUS (Small Angle Muon System) toroids have been designed and fabricated in the USSR and delivered to D0 ready for installation into the D0 detector. These toroids will be installed into the aperture of the EF's (End Toroids). The aperture in the EF's is 72-inch vertically and 66-inch horizontally. The Samus toroid is 70-inch vertically by 64-inch horizontally by 66-inch long and weighs approximately 38 tons. The Samus toroid has a 20-inch by 20-inch aperture in the center and it is through this aperture that the lift fixture must fit. The toroid must be 'threaded' through the EF aperture. Further, the Samus toroid coils are wound about the vertical portion of the aperture and thus limit the area where a lift fixture can make contact and not damage the coils. The fixture is designed to lift along a surface adjacent to the coils, but with clearance to the coil and with contact to the upper steel block of the toroid. The lift and installation will be done with the 50 ton crane at DO. The fixture was tested by lifting the Samus Toroid 2-inch off the floor and holding the weight for 10 minutes. Deflection was as predicted by the design calculations. Enclosed are sketches of the fixture and it relation to both Toroids (Samus and EF), along with hand calculations and an Finite Element Analysis. The PEA work was done by Kay Weber of the Accelerator Engineering Department.

  2. Residential and Light Commercial HVAC. Teacher Edition and Student Edition. Second Edition.

    Science.gov (United States)

    Stephenson, David

    This package contains teacher and student editions of a residential and light commercial heating, ventilation, and air conditioning (HVAC) course of study. The teacher edition contains information on the following: using the publication; national competencies; competency profile; related academic and workplace skills list; tools, equipment, and…

  3. Tool and Fixture Design

    Energy Technology Data Exchange (ETDEWEB)

    Graham, Mark W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-28

    In a manufacturing process, a need is identified and a product is created to fill this need. While design and engineering of the final product is important, the tools and fixtures that aid in the creation of the final product are just as important, if not more so. Power supplies assembled at the TA-55 PF-5 have been designed by an excellent engineering team. The task in PF-5 now is to ensure that all steps of the assembly and manufacturing process can be completed safely, reliably, and in a quality repeatable manner. One of these process steps involves soldering fine wires to an electrical connector. During the process development phase, the method of soldering included placing the power supply in a vice in order to manipulate it into a position conducive to soldering. This method is unacceptable from a reliability, repeatability, and ergonomic standpoint. To combat these issues, a fixture was designed to replace the current method. To do so, a twelve step engineering design process was used to create the fixture that would provide a solution to a multitude of problems, and increase the safety and efficiency of production.

  4. Lighting.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-09-01

    Since lighting accounts for about one-third of the energy used in commercial buildings, there is opportunity to conserve. There are two ways to reduce lighting energy use: modify lighting systems so that they used less electricity and/or reduce the number of hours the lights are used. This booklet presents a number of ways to do both. Topics covered include: reassessing lighting levels, reducing lighting levels, increasing bulb & fixture efficiency, using controls to regulate lighting, and taking advantage of daylight.

  5. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy's Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE's Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  6. Analysis of federal policy options for improving US lighting energy efficiency: Commercial and residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson, B.A.; McMahon, J.E.; Mills, E.; Chan, P.; Chan, T.W.; Eto, J.H.; Jennings, J.D.; Koomey, J.G.; Lo, K.W.; Lecar, M.; Price, L.; Rubinstein, F.; Sezgen, O.; Wenzel, T.

    1992-12-01

    The US Department of Energy (DOE) has recognized the opportunity to achieve energy, economic, and environmental benefits by promoting energy-efficient lighting through federal policies, including lighting standards, financial incentives, and information programs. To assist in this process, the Office of Conservation and Renewable Energy`s Office of Codes and Standards invited Lawrence Berkeley Laboratory to assess prospective national impacts for a variety of policy options. Some progress has already been made in developing lighting policies at both the federal and state levels. The US DOE`s Office of Building Technologies has evaluated lighting efficiency incentives as part of its analysis for the National Energy Strategy. Fluorescent and incandescent lamp standards are included in the national Energy Policy Act of 1992 (P.L. 102-486, October 24, 1992). A few states have analyzed or implemented lamp and luminaire standards. Many policy-related issues merit further investigation. For example, there is considerable debate over issues such as mandatory or voluntary standards versus component labeling and other education-oriented strategies. Several different technologies are involved that interact with each other-lamps (incandescent, compact fluorescent, and HID), ballasts (for fluorescent and HID lamps), and fixtures with reflectors and lenses. Control systems and operation patterns must also be considered (timers, automated dimming, or occupancy sensors). Lighting applications are diverse, ranging from offices, restaurants, hallways, hospital operating rooms, to exterior lights. Lighting energy use influences heating and cooling requirements in buildings. Successful lighting system design must also address interactions between architectural design elements and daylighting availability. Proper system installation and ongoing operation and maintenance are crucial. The economic aspects of the preceding points must also be considered for policy making.

  7. Heat transfer assembly for a fluorescent lamp and fixture

    Science.gov (United States)

    Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

    1992-12-29

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

  8. Fixture for aligning motor assembly

    Science.gov (United States)

    Shervington, Roger M.; Vaghani, Vallabh V.; Vanek, Laurence D.; Christensen, Scott A.

    2009-12-08

    An alignment fixture includes a rotor fixture, a stator fixture and a sensor system which measures a rotational displacement therebetween. The fixture precisely measures rotation of a generator stator assembly away from a NULL position referenced by a unique reference spline on the rotor shaft. By providing an adjustable location of the stator assembly within the housing, the magnetic axes within each generator shall be aligned to a predetermined and controlled tolerance between the generator interface mounting pin and the reference spline on the rotor shaft. Once magnetically aligned, each generator is essentially a line replaceable unit which may be readily mounted to any input of a multi-generator gearbox assembly with the assurance that the magnetic alignment will be within a predetermined tolerance.

  9. Case-based Agile Fixture Design

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In order to realize the agility of the fixture design, such asreconfigurability, rescalability and reusability, fixture structure is function unit-based decomposed from a fire-new point of view. Which makes it easy for agile fixture to be reconfigured and modified. Thereby, the base of case-based agile fixture design system info is established.Whole case-based agile fixture design model is presented. In which, three modules are added relative to the other models, including case matching of fixture planning module, conflict arbitration module and agile fixture case modify module. The three modules could solve the previous problem that the experience and result are difficult to be reused in the process of design.Two key techniques in the process of the agile fixture design, the evaluation of case similarity, and restriction-based conflict arbitration, are listed. And some methods are presented to evaluate the similarity and clear up the conflict.

  10. Chapter 6: Residential Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dimetrosky, Scott [Apex Analytics, LLC, Boulder, CO (United States); Parkinson, Katie [Apex Analytics, LLC, Boulder, CO (United States); Lieb, Noah [Apex Analytics, LLC, Boulder, CO (United States)

    2017-10-19

    Given new regulations, increased complexity in the market, and the general shift from CFLs to LEDs, this evaluation protocol was updated in 2017 to shift the focus of the protocols toward LEDs and away from CFLs and to resolve evaluation uncertainties affecting residential lighting incentive programs.

  11. Fixture for assembling solar panels

    Science.gov (United States)

    Dillard, P. A.; Fritz, W. M.

    1979-01-01

    Vacuum fixture attaches array of silicon solar cells to mounting plate made of clear glass which holds and protects cells. Glass plate transmits, rather than absorbs, solar energy thus cooling cells for efficient operation. Device therefore reduces handling of cells and interconnecting conductors to one operation.

  12. Optical fiber cable chemical stripping fixture

    Science.gov (United States)

    Kolasinski, John R. (Inventor); Coleman, Alexander M. (Inventor)

    1995-01-01

    An elongated fixture handle member is connected to a fixture body member with both members having interconnecting longitudinal central axial bores for the passage of an optical cable therethrough. The axial bore of the fixture body member, however, terminates in a shoulder stop for the outer end of a jacket of the optical cable covering both an optical fiber and a coating therefor, with an axial bore of reduced diameter continuing from the shoulder stop forward for a predetermined desired length to the outer end of the fixture body member. A subsequent insertion of the fixture body member including the above optical fiber elements into a chemical stripping solution results in a softening of the exposed external coating thereat which permits easy removal thereof from the optical fiber while leaving a desired length coated fiber intact within the fixture body member.

  13. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

    2011-06-01

    Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The

  14. Fixture For Mounting A Pressure Sensor

    Science.gov (United States)

    Cagle, Christopher M.

    1995-01-01

    Fixture for mounting pressure sensor in aerodynamic model simplifies task of removal and replacement of sensor in event sensor becomes damaged. Makes it unnecessary to dismantle model. Also minimizes any change in aerodynamic characteristics of model in event of replacement. Removable pressure sensor installed in fixture in wall of model. Wires from sensor pass through channel under surface.

  15. Fixturing error measurement and analysis using CMMs

    International Nuclear Information System (INIS)

    Wang, Y; Chen, X; Gindy, N

    2005-01-01

    Influence of fixture on the errors of a machined surface can be very significant. The machined surface errors generated during machining can be measured by using a coordinate measurement machine (CMM) through the displacements of three coordinate systems on a fixture-workpiece pair in relation to the deviation of the machined surface. The surface errors consist of the component movement, component twist, deviation between actual machined surface and defined tool path. A turbine blade fixture for grinding operation is used for case study

  16. Seismic responses of unanchored electrode storage fixtures

    International Nuclear Information System (INIS)

    Ting-shu Wu; Blomquist, C.A.; Haupt, H.J.; Herceg, J.E.

    1993-01-01

    Two anchored electrode storage fixtures will be installed in the process cell of the Integral Fast Reactor's Fuel Cycle Facility at ANL-W in Idaho. In addition to the concerns for structural integrity, the potential for uplifting and tipping of the fixtures during the design basis earthquake must also be examined. In the analysis, a response-spectrum method was employed to investigate tipping, while a static approach was used for the structural-integrity evaluations. The results show that the combined stresses from seismic and other loads are within the allowables permitted by the design codes. The overall vertical seismic reaction forces at the leveling pads are compressive, implying that the fixtures will remain in contact with the floor. No uplifting or tipping of the fixture will occur during the design basis earthquake

  17. FIXTURING DEVICE FOR DRILLING A STRAIGHT SHAFT

    Directory of Open Access Journals (Sweden)

    SUSAC, Florin

    2017-05-01

    Full Text Available The paper presents a fixturing device used for machining by drilling a straight shaft. The shaft was manufactured on EMCO CONCEPT TURN 55 CNC. The blank used was a bar with circular cross-section. The orientation and fixing scheme of the part and the orientation elements for fixturing device are presented as they were drawn in Autodesk Inventor and AutoCAD software.

  18. Design of jigs, fixtures and press tools

    CERN Document Server

    Venkataraman, K

    2015-01-01

    Textbook presenting the fundamentals of tool design with special focus on jigs, fixtures and die design Covers sections on sheet metal forming processes; turning, grinding, broaching, welding and modular fixtures; principles of clamping; and an Introduction to Presses and Auxiliary Equipment Author has many years' experience in both academic and industrial environments, and presents this work in an easily-accessible style End of chapter questions and answers assist the learning process for both practicing tooling designers and engineers, and manufacturing en

  19. Energy efficiency of lighting systems in residential buildings; Energieeffizienzsteigerung der Beleuchtungstechnik in Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Troeger, Andreas [Technische Univ. Dresden (Germany). Elektrotechnisches Inst.; Wittig, Michael; Schlosser, Roman; Wuerfel, Matthias [Westsaechsische Hochschule Zwickau (Germany). Fakultaet Elektrotechnik

    2011-07-01

    Due to political demands such as the law of an eco-friendly-design of Energy Using Products (EBPG), the production and thus the long-term use of conventional light bulbs is no longer possible within the European Union. Energy saving light bulbs are preferred as replacement for those bulbs. However, these lighting systems have unfavourable properties for certain areas of applications, such as low luminance during the heating phase or a low lifetime if used under strongly fluctuating stress. Therefore, using conventional light bulbs in stairwells, their properties are of great disadvantage. The paper examines possible applications for LED lighting systems (Light Emitting Diode), meeting the standards. Investigations of possible on-demand switching or dimming of LED lighting have been executed with the help of presence or movement sensors and by using smart grids such as the KNX-compliant components. Furthermore, technical requirements, economic viability and energetic advantages and disadvantages of separate DC power networks for the operating of the LED lights have been tested. Since energy storage increased in rental buildings, the storage system DC supply can be used for DC power of such consumers. In this way, the AC and the rectifier losses can be avoided and thus the energy efficiency of lighting can be increased in rental buildings. To implement the project a model of a staircase has been created by using the simulation software DIALux. Furthermore the given lighting conditions have been measured in the stairwell. Thus, the staircase model yields comparative results. (orig.)

  20. Design and Analysis of an Optical Coupler for Concentrated Solar Light Using Optical Fibers in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Afshin Aslian

    2016-01-01

    Full Text Available Concentrated sunlight that is transmitted by fiber optics has been used for generating electricity, heat, and daylight. On the other hand, multijunction photovoltaic cells provide high efficiency for generating electricity from highly concentrated sunlight. This study deals with designing and simulating a high-efficiency coupler, employing a mathematical model to connect sunlight with fiber optics for multiple applications. The coupler concentrates and distributes irradiated light from a primary concentrator. In this study, a parabolic dish was used as the primary concentrator, a coupler that contains nine components called a compound truncated pyramid and a cone (CTPC, all of which were mounted on a plate. The material of both the CTPC and the plate was BK7 optical glass. Fiber optics cables and multijunction photovoltaic cells were connected to the cylindrical part of the CTPC. The fibers would transmit the light to the building to provide heat and daylight, whereas multijunction photovoltaic cells generate electricity. Theoretical and simulation results showed high performance of the designed coupler. The efficiency of the coupler was as high as 92%, whereas the rim angle of the dish increased to an optimum angle. Distributed sunlight in the coupler increased the flexibility and simplicity of the design, resulting in a system that provided concentrated electricity, heat, and lighting for residential buildings.

  1. Extended Life PZT Stack Test Fixture

    Science.gov (United States)

    Badescu, Mircea; Sherrit, S.; Bao, X.; Aldrich, J.; Bar-Cohen, Y.; Jones, C.

    2009-01-01

    Piezoelectric stacks are being sought to be used as actuators for precision positioning and deployment of mechanisms in future planetary missions. Beside the requirement for very high operation reliability, these actuators are required for operation at space environments that are considered harsh compared to normal terrestrial conditions.These environmental conditions include low and high temperatures and vacuum or high pressure. Additionally, the stacks are subjected to high stress and in some applications need to operate with a very long lifetime durability.Many of these requirements are beyond the current industry design margins for nominal terrestrial applications. In order to investigate some of the properties that will indicate the durability of such actuators and their limitations we have developed a new type of test fixture that can be easily integrated in various test chambers for simulating environmental conditions, can provide access for multiple measurements while being exposed to adjustable stress levels. We designed and built two test fixtures and these fixtures were made to be adjustable for testing stacks with different dimensions and can be easily used in small or large numbers. The properties that were measured using these fixtures include impedance, capacitance, dielectric loss factor, leakage current, displacement, breakdown voltage, and lifetime performance. The fixtures characteristics and the test capabilities are presented in this paper.

  2. The lighting of residential yards. Paper presented at the 19th Session of the Commission Internationale de l'Eclairage (CIE), Kyoto, Japan, 1979.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1979-01-01

    The "woonerf" is conceived in order to enhance the amenity in residential districts. It is put into effect by a series of legal measures, road construction and traffic management measures, planning measures and social measures. The quality requirements for the public lighting include apart of

  3. Ball mounting fixture for a roundness gage

    Science.gov (United States)

    Gauler, Allen L.; Pasieka, Donald F.

    1983-01-01

    A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.

  4. Replacement policy of residential lighting optimized for cost, energy, and greenhouse gas emissions

    Science.gov (United States)

    Liu, Lixi; Keoleian, Gregory A.; Saitou, Kazuhiro

    2017-11-01

    Accounting for 10% of the electricity consumption in the US, artificial lighting represents one of the easiest ways to cut household energy bills and greenhouse gas (GHG) emissions by upgrading to energy-efficient technologies such as compact fluorescent lamps (CFL) and light emitting diodes (LED). However, given the high initial cost and rapidly improving trajectory of solid-state lighting today, estimating the right time to switch over to LEDs from a cost, primary energy, and GHG emissions perspective is not a straightforward problem. This is an optimal replacement problem that depends on many determinants, including how often the lamp is used, the state of the initial lamp, and the trajectories of lighting technology and of electricity generation. In this paper, multiple replacement scenarios of a 60 watt-equivalent A19 lamp are analyzed and for each scenario, a few replacement policies are recommended. For example, at an average use of 3 hr day-1 (US average), it may be optimal both economically and energetically to delay the adoption of LEDs until 2020 with the use of CFLs, whereas purchasing LEDs today may be optimal in terms of GHG emissions. In contrast, incandescent and halogen lamps should be replaced immediately. Based on expected LED improvement, upgrading LED lamps before the end of their rated lifetime may provide cost and environmental savings over time by taking advantage of the higher energy efficiency of newer models.

  5. Research on the design of fixture for motor vibration test

    Science.gov (United States)

    Shen, W. X.; Ma, W. S.; Zhang, L. W.

    2018-03-01

    The vibration reliability of the new energy automobile motor plays a very important role in driving safety, so it is very important to test the vibration durability of the motor. In the vibration test process, the fixture is very important, simulated road spectrum signal vibration can be transmitted without distortion to the motor through the fixture, fixture design directly affect the result of vibration endurance test. On the basis of new energy electric vehicle motor concrete structure, Two fixture design and fixture installation schemes for lateral cantilever type and base bearing type are put forward in this article, the selection of material, weighting process, middle alignment process and manufacturing process are summarized.The modal analysis and frequency response calculation of the fixture are carried out in this design, combine with influence caused by fixture height and structure profile on response frequency, the response frequency of each order of the fixture is calculated, then ultimately achieve the purpose of guiding the design.

  6. 10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.

    Science.gov (United States)

    2010-01-01

    ... high intensity discharge fixture, the efficiency of a lamp and ballast combination, expressed as a... lamps. Metal halide lamp means a high intensity discharge lamp in which the major portion of the light... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning metal halide lamp ballasts and...

  7. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    Science.gov (United States)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  8. Interrogation cradle and insertable containment fixture for detecting birefringent microcrystals in bile

    Science.gov (United States)

    Darrow, Chris; Seger, Tino

    2003-09-30

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.

  9. STANDALONE PHOTOVOLTAIC SYSTEMS SIZING OPTIMIZATION USING DESIGN SPACE APPROACH: CASE STUDY FOR RESIDENTIAL LIGHTING LOAD

    Directory of Open Access Journals (Sweden)

    D. F. AL RIZA

    2015-07-01

    Full Text Available This paper presents a sizing optimization methodology of panel and battery capacity in a standalone photovoltaic system with lighting load. Performance of the system is identified by performing Loss of Power Supply Probability (LPSP calculation. Input data used for the calculation is the daily weather data and system components parameters. Capital Cost and Life Cycle Cost (LCC is calculated as optimization parameters. Design space for optimum system configuration is identified based on a given LPSP value, Capital Cost and Life Cycle Cost. Excess energy value is used as an over-design indicator in the design space. An economic analysis, including cost of the energy and payback period, for selected configurations are also studied.

  10. Analytic Hierarchy Process & Multi Attribute Utility Theory Based Approach for the Selection of Lighting Systems in Residential Buildings: A Case Study

    Directory of Open Access Journals (Sweden)

    Othman Alshamrani

    2018-05-01

    Full Text Available This paper presents an approach developed for selecting lighting systems in residential buildings using an Analytic Hierarchy Process (AHP and the Multi Criteria Decision Making Technique (MCDMT. The developed approach considers four selection criteria of lighting systems: life-cycle cost, illumination, environmental performance, and life-span. The criteria of selection, along with the most widely used lighting systems in residential buildings, were determined through questionnaire surveys with suppliers, maintenance managers, and lighting experts. The Analytic Hierarchy Process and Multi Attribute Utility Theory were utilized to assess the significant influence of the identified main and sub-criteria on the selection process, from the design point of view. The developed approach was tested on a real case project in selecting the lighting system for aresidential building in Saudi Arabia. The obtained results show that the life-cycle cost and illumination proprieties, followed by the service life were found to be the most influential measures in the selection process. The results also show that Light-Emitting Diode(LED lighting systems prove to bear the highest initial cost while sustaining the best overall performance.

  11. Virtual Environment as a Design Tool for Sustainable Residential Spaces in Light of Theory of Planned Behavior

    Directory of Open Access Journals (Sweden)

    Hebatalla Sherin Nazmy

    2016-01-01

    Full Text Available This study aims to reveal the impact of Virtual Environment as a design tool on the interior architect's design behavior towards adopting sustainable residential interior design practices. This approach is guided by the Theory of Planned Behaviour as a theoretical framework; the purpose as such would serve to bridge the gap between theoretical knowledge and its practical implementation to promote sustainable design practices. Findings revealed that Virtual Environment is anticipated to assist the interior architect in integrating the complex sustainable residential design objectives, and thus positively affect the interior architect's behavioral performance towards embracing sustainable residential design solutions.

  12. Sunscope natural light systems : tubular skylights

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This brochure described a tubular skylight designed by Sunscope Natural Light Systems. The Sunscope is a super-reflective light system in which daylight is reflected down a cylinder to a translucent ceiling fixture that diffuses natural light throughout the room in which it is placed. The Sunscope requires no structure changes, is installed in less than 3 hours, and requires no drywall repairs or repainting. The system eliminates the need for daytime electric lighting, and causes no winter heat losses or summer heat gains. Available in 3 sizes, the Sunscope has no moving parts and is fully maintenance-free. The system was designed for use in commercial and residential applications. 7 figs.

  13. Human annoyance, acceptability and concern as responses to vibration from the construction of Light Rapid Transit lines in residential environments

    Energy Technology Data Exchange (ETDEWEB)

    Wong-McSweeney, D., E-mail: D.B.C.WongMcSweeney@salford.ac.uk [Acoustics Research Centre, University of Salford, Salford M5 4TW (United Kingdom); Woodcock, J.S.; Peris, E.; Waddington, D.C.; Moorhouse, A.T. [Acoustics Research Centre, University of Salford, Salford M5 4TW (United Kingdom); Redel-Macías, M.D. [Dep. Rural Engineering Campus de Rabanales, University of Córdoba, Córdoba (Spain)

    2016-10-15

    The aim of this paper is to investigate the use of different self-reported measures for assessing the human response to environmental vibration from the construction of an urban LRT (Light Rapid Transit) system. The human response to environmental stressors such as vibration and noise is often expressed in terms of exposure–response relationships that describe annoyance as a function of the magnitude of the vibration. These relationships are often the basis of noise and vibration policy and the setting of limit values. This paper examines measures other than annoyance by expressing exposure–response relationships for vibration in terms of self-reported concern about property damage and acceptability. The exposure–response relationships for concern about property damage and for acceptability are then compared with those for annoyance. It is shown that concern about property damage occurs at vibration levels well below those where there is any risk of damage. Earlier research indicated that concern for damage is an important moderator of the annoyance induced. Acceptability, on the other hand, might be influenced by both annoyance and concern, as well as by other considerations. It is concluded that exposure–response relationships expressing acceptability as a function of vibration exposure could usefully complement existing relationships for annoyance in future policy decisions regarding environmental vibration. The results presented in this paper are derived from data collected through a socio-vibration survey (N = 321) conducted for the construction of an urban LRT in the United Kingdom. - Highlights: • The human response to construction vibration is assessed in residential environments. • Exposure–response relationships are generated based on survey and semi-empirical vibration estimation. • Annoyance, concern and acceptability are compared as response measures. • Concern and acceptability are viable measures complementing annoyance.

  14. Development of sacrificial support fixture using deflection analysis

    Science.gov (United States)

    Ramteke, Ashwini M.; Ashtankar, Kishor M.

    2018-04-01

    Sacrificial support fixtures are the structures used to hold the part during machining while rotating the part about the fourth axis of CNC machining. In Four axis CNC machining part is held in a indexer which is rotated about the fourth axis of rotation. So using traditional fixturing devices to hold the part during machining such as jigs, v blocks and clamping plates needs a several set ups, manufacturing time which increase the cost associated with it. Since the part is rotated about the axis of rotation in four axis CNC machining so using traditional fixturing devices to hold the part while machining we need to reorient the fixture each time for particular orientation of part about the axis of rotation. So our proposed methodology of fixture design eliminates the cost associate with the complicated fixture design for customized parts which in turn reduces the time of manufacturing of the fixtures. But while designing the layout of the fixtures it is found out that the machining the part using four axis CNC machining the accurate machining of the part is directly proportional to the deflection produced in a part. So to machine an accurate part the deflection produced in a part should be minimum. We assume that the deflection produced in a part is a result of the deflection produced in a sacrificial support fixture while machining. So this paper provides the study of the deflection checking in a part machined using sacrificial support fixture by using FEA analysis.

  15. Computer aided fixture design - A case based approach

    Science.gov (United States)

    Tanji, Shekhar; Raiker, Saiesh; Mathew, Arun Tom

    2017-11-01

    Automated fixture design plays important role in process planning and integration of CAD and CAM. An automated fixture setup design system is developed where when fixturing surfaces and points are described allowing modular fixture components to get automatically select for generating fixture units and placed into position with satisfying assembled conditions. In past, various knowledge based system have been developed to implement CAFD in practice. In this paper, to obtain an acceptable automated machining fixture design, a case-based reasoning method with developed retrieval system is proposed. Visual Basic (VB) programming language is used in integrating with SolidWorks API (Application programming interface) module for better retrieval procedure reducing computational time. These properties are incorporated in numerical simulation to determine the best fit for practical use.

  16. Testing Fixture For Microwave Integrated Circuits

    Science.gov (United States)

    Romanofsky, Robert; Shalkhauser, Kurt

    1989-01-01

    Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

  17. Stress Analysis of the D-Zero Solenoid Magnet Lifting Fixture PPD Fixture No.102

    International Nuclear Information System (INIS)

    Zaczek, M.

    1997-01-01

    This engineering note presents stress analysis calculations for the below the hook lifting fixture which will be used to move the D-Zero solenoid magnet during installation work at the D-Zero Assembly building. Load bearing structural members are shown to have a minimum design factor of 3 based on yield strength as required by ASME B30.20. All bolts were analyzed and shown to be kept below allowable loads/stresses listed in the American Institute of Steel Construction (AISC) manual. The lifting fixture will be manufactured at Fermilab using some material scavenged from an existing lifting fixture that was shipped with the magnet from the magnet manufacturer, Toshiba Corporation. The fixture is designed with built in versatility so that the solenoid magnet can be maneuvered through the stages of preparation and installation into it's final mounted position. The structure has been analyzed for all phases of its use, although the analysis of the structure as a below the hook lifting device is the main purpose of this note.

  18. Self-aligning fixture used in lathe chuck jaw refacing

    Science.gov (United States)

    Linn, C. C.

    1965-01-01

    Self-aligning tool positions and rigidly holds lathe chuck jaws for refacing and truing of the clamping surface. The jaws clamp the fixture in the manner of clamping a workpiece. The fixture can be modified to accommodate four-jawed checks.

  19. 24 CFR 3280.807 - Fixtures and appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fixtures and appliances. 3280.807... Fixtures and appliances. (a) Electrical materials, devices, appliances, fittings, and other equipment... fasten appliances when the manufactured home is in transit. (See § 3280.809.) (b) Specifically listed...

  20. Application of remote source lighting system in different layouts of enclosed lift lobbies in highrise residential building of central core design

    Energy Technology Data Exchange (ETDEWEB)

    Wong, I.; Yang, H.X. [Hong Kong Polytechnic Univ., Hung Hom, Hong Kong (China). Dept. of Building Services, Renewable Energy Research Group

    2010-07-01

    This paper reported on a simulation study that explored a new building philosophy that optimizes solar energy to minimize reliance on fossil fuels and to design energy conscious buildings that minimize the energy needed for lighting and cooling. The viability of applying a remote source lighting (RSL) system to transmit daylight into central core lobbies in high-rise residential buildings in Hong Kong was demonstrated. These lobbies are usually enclosed without any windows, thus requiring electric lighting to be switched on 24 hours continuously, consuming non-renewable energy in most cases. In this study, the RSL system was composed of small diameter light pipes and optic fibers. The system transports daylight from the exterior to illuminate the enclosed lobbies. The simulation was conducted to analyze and compare the light transmission efficiency when applying the RSL system to different layouts of the lift lobbies. It was concluded that the efficiency of the RSL system is governed by the length and number of turns in the lobby. 13 refs., 12 figs.

  1. Automatic design of 3-d fixtures and assembly pallets

    Energy Technology Data Exchange (ETDEWEB)

    Brost, R.C.; Peters, R.R. [Sandia National Labs., Albuquerque, NM (United States). Intelligent Systems and Robotics Center

    1997-01-01

    This paper presents an implemented algorithm that automatically designs fixtures and assembly pallets to hold three-dimensional parts. All fixtures generated by the algorithm employ round side locators, a side clamp, and cylindrical supports; depending on the value of an input control flag, the fixture may also include swing-arm top clamps. Using these modular elements, the algorithm designs fixtures that rigidly constrain and locate the part, obey task constraints, are robust to part shape variations, are easy to load, and are economical to produce. For the class of fixtures that are considered, the algorithm is guaranteed to find the global optimum design that satisfies these and other pragmatic conditions. The authors present the results of the algorithm applied to several practical manufacturing problems. For these complex problems the algorithm typically returns initial high-quality fixture designs in less than a minute, and identifies the global optimum design in just over an hour. The algorithm is also capable of solving difficult design problems where a single fixture is desired that can hold either of two parts.

  2. The effect on emotions and brain activity by the direct/indirect lighting in the residential environment.

    Science.gov (United States)

    Shin, Yu-Bin; Woo, Seung-Hyun; Kim, Dong-Hyeon; Kim, Jinseong; Kim, Jae-Jin; Park, Jin Young

    2015-01-01

    This study was performed to explore how direct/indirect lighting affects emotions and brain oscillations compared to the direct lighting when brightness and color temperature are controlled. Twenty-eight subjects (12 females; mean age 22.5) participated. The experimental conditions consisted of two lighting environments: direct/indirect lighting (400 lx downlight, 300 lx uplight) and direct lighting (700 lx downlight). On each trial, a luminance environment was presented for 4 min, followed by participants rated their emotional feelings of the lighting environment. EEG data were recorded during the experiment. Spectral analysis was performed for the range of delta, theta, alpha, beta, and gamma ranges. The participants felt cooler and more pleasant and theta oscillations on the F4, F8, T4, and TP7 electrodes were more enhanced in the direct/indirect lighting environment compared to the direct lighting environment. There was significant correlation between the "cool" rating and the theta power of the F8 electrode. The participants felt more pleasant in the direct/indirect lighting environment, indicating that space with direct/indirect lighting modulated subjective perception. Additionally, our results suggest that theta oscillatory activity can be used as a biological marker that reflects emotional status in different lighting environments. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Characterization and environmental risk assessment of heavy metals in construction and demolition wastes from five sources (chemical, metallurgical and light industries, and residential and recycled aggregates).

    Science.gov (United States)

    Gao, Xiaofeng; Gu, Yilu; Xie, Tian; Zhen, Guangyin; Huang, Sheng; Zhao, Youcai

    2015-06-01

    Total concentrations of heavy metals (Cu, Zn, Pb, Cr, Cd, and Ni) were measured among 63 samples of construction and demolition (C&D) wastes collected from chemical, metallurgical and light industries, and residential and recycled aggregates within China for risk assessment. The heavy metal contamination was primarily concentrated in the chemical and metallurgical industries, especially in the electroplating factory and zinc smelting plant. High concentrations of Cd were found in light industry samples, while the residential and recycled aggregate samples were severely polluted by Zn. Six most polluted samples were selected for deep research. Mineralogical analysis by X-ray fluorescence (XRF) spectrometry and X-ray diffraction (XRD), combined with element speciation through European Community Bureau of Reference (BCR) sequential extraction, revealed that a relatively slight corrosion happened in the four samples from electroplating plants but high transfer ability for large quantities of Zn and Cu. Lead arsenate existed in the acid extractable fraction in CI7-8 and potassium chromium oxide existed in the mobility fraction. High concentration of Cr could be in amorphous forms existing in CI9. The high content of sodium in the two samples from zinc smelter plants suggested severe deposition and erosion on the workshop floor. Large quantities of Cu existed as copper halide and most of the Zn appeared to be zinc, zinc oxide, barium zinc oxide, and zincite. From the results of the risk assessment code (RAC), the samples from the electroplating factory posed a very high risk of Zn, Cu, and Cr, a high risk of Ni, a middle risk of Pb, and a low risk of Cd. The samples from the zinc smelting plant presented a high risk of Zn, a middle risk of Cu, and a low risk of Pb, Cr, Cd, and Ni.

  4. Novel Adaptive Fixturing for Thin Walled Aerospace Parts

    International Nuclear Information System (INIS)

    Merlo, Angelo; Ricciardi, Donato; Salvi, Edoardo; Fantinati, Dario; Iorio, Ernesto

    2011-01-01

    In the aerospace industry the monolithic structures have been introduced to reduce the costs of assembling large numbers of components. The expected benefit of using thin walled monolithic parts is given by a large reduction in the overall manufacturing costs, nevertheless this kind of component encounters a critical phase in fixturing. Fixtures are used to locate and hold workpieces during manufacturing. Because workpiece surface errors and fixture set-up errors (called source errors) always exist, the fixtured workpiece will consequently have position and/or orientation errors (called resultant errors) that will definitely affect the final machining accuracy. Most often the current clamping procedure is not straightforward, it implies several steps and the success of the operation hardly depends by the skill of the human operator. It is estimated that fixturing could constitute 10-20% of the total manufacturing costs, assuming that the fixtures are amortized over relatively small batches. Fixturing devices must satisfy two requisites, which, in some terms, are opposite: - to provide relatively high forces in order to guarantee that the workpiece will be maintained in position under the maximum cutting forces; - to reduce as much as possible strains induced in the workpiece. Limiting the strains induced in the workpiece is crucial because of elastic strain recovery: releasing the clamped workpiece would result in an unwanted final deformation. In this paper a novel adaptive fixturing based on active clamping forces (supplied by piezoelectric actuators) is presented: a real aerospace part case study, - a Nozzle Guide Vane (NGV) -, is introduced, the related problems are identified, and the adopted solutions shown. The proposed adaptive fixturing device can lead to the following advantages: - to perform an automatic errors-free workpiece clamping and then drastically reduce the overall fixturing set up time; - to recover unwanted strains induced to the workpiece, in

  5. Implant Fixture Heat Transfer During Abutment Preparation.

    Science.gov (United States)

    Aleisa, Khalil; Alkeraidis, Abdullah; Al-Dwairi, Ziad Nawaf; Altahawi, Hamdi; Lynch, Edward

    2015-06-01

    The purpose of the study was to evaluate the effect of water flow rate on the heat transmission in implants during abutment preparation using a diamond bur in a high-speed dental turbine. Titanium-alloy abutments (n = 32) were connected to a titanium-alloy implant embedded in an acrylic resin within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each) according to the water flow rate used during the preparation phase. Group 1 had a water flow rate of 24 mL/min, and group 2 had a water flow rate of 40 mL/min. Each abutment was prepared in the axial plane for 1 minute and in the occlusal plane for 1 minute with a coarse tapered diamond bur using a high-speed dental handpiece. Thermocouples embedded at the cervix of the implant surface were used to record the temperature of heat transmission from the abutment preparation. Heat generation was measured at 3 distinct times (immediately and 30 seconds and 60 seconds after the end of preparation). Statistical analyses were carried out using 2-way analysis of variance and the Student t test. Water flow rates (24 mL vs 40 mL) and time interval had no statistically significant effect on the implant's temperature change during the abutment preparation stage (P = .431 and P = .064, respectively). Increasing the water flow rate from 24 to 40 mL/min had no influence on the temperature of the implant fixture recorded during preparation of the abutment.

  6. Residential Care

    Science.gov (United States)

    ... Kids For Teens For Parents & Teachers Resolving Family Conflicts The Holidays and Alzheimer's Glossary Virtual Library Online ... longer an option Costs Choosing a care setting Types of residential care A good long-term care ...

  7. SFR test fixture for hemispherical and hyperhemispherical camera systems

    Science.gov (United States)

    Tamkin, John M.

    2017-08-01

    Optical testing of camera systems in volume production environments can often require expensive tooling and test fixturing. Wide field (fish-eye, hemispheric and hyperhemispheric) optical systems create unique challenges because of the inherent distortion, and difficulty in controlling reflections from front-lit high resolution test targets over the hemisphere. We present a unique design for a test fixture that uses low-cost manufacturing methods and equipment such as 3D printing and an Arduino processor to control back-lit multi-color (VIS/NIR) targets and sources. Special care with LED drive electronics is required to accommodate both global and rolling shutter sensors.

  8. Residential Waste

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund; Fruergaard, Thilde; Matsufuji, Y.

    2011-01-01

    are discussed in this chapter. Characterizing residential waste is faced with the problem that many residences already divert some waste away from the official collection systems, for example performing home composting of vegetable waste and garden waste, having their bundled newspaper picked up by the scouts...... twice a year or bringing their used furniture to the flea markets organized by charity clubs. Thus, much of the data available on residential waste represents collected waste and not necessarily all generated waste. The latter can only be characterized by careful studies directly at the source......, but such studies are very expensive if fair representation of both spatial and temporal variations should be obtained. In addition, onsite studies may affect the waste generation in the residence because of the increased focus on the issue. Residential waste is defined in different ways in different countries...

  9. Optimization of machining fixture layout for tolerance requirements ...

    African Journals Online (AJOL)

    Dimensional accuracy of workpart under machining is strongly influenced by the layout of the fixturing elements like locators and clamps. Setup or geometrical errors in locators result in overall machining error of the feature under consideration. Therefore it is necessary to ensure that the layout is optimized for the desired ...

  10. Space vehicle electromechanical system and helical antenna winding fixture

    Science.gov (United States)

    Judd, Stephen; Dallmann, Nicholas; Guenther, David; Enemark, Donald; Seitz, Daniel; Martinez, John; Storms, Steven

    2017-12-26

    A space vehicle electromechanical system may employ an architecture that enables convenient and practical testing, reset, and retesting of solar panel and antenna deployment on the ground. A helical antenna winding fixture may facilitate winding and binding of the helical antenna.

  11. Estimated health impact of a shift from light fuel to residential wood-burning in Upper Austria.

    Science.gov (United States)

    Haluza, Daniela; Kaiser, August; Moshammer, Hanns; Flandorfer, Claudia; Kundi, Michael; Neuberger, Manfred

    2012-07-01

    The dependency on carbon-based fossil energy and growing awareness of climate change issues has induced ambitious policy initiatives to promote renewable energy sources for indoor heating. Combustion of regionally available material such as wood is considered a carbon-neutral alternative for oil and gas, but unregulated revival of wood stoves may cause detrimental health effects. For the prognosis of the health impact of air pollution due to the use of wood stoves, Upper Austria served for a case study. On the basis of recent measurements of particulate matter fuel oil by either fossil gas or biomass, and for scenario 3, replacement of light fuel oil by biomass only. Compared with the current exposure from scenario 1, the increased annual mean PM10 levels are estimated to lead to 101 (95% CI 56;146) and 174 (95% CI 92;257) additional deaths among 1.4 million inhabitants per year for scenarios 2 and 3, respectively. Without adequate strategies for reducing the emissions of domestic heating facilities, replacement of fossil energy sources could lead to an increased health risk.

  12. 78 FR 51463 - Energy Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures

    Science.gov (United States)

    2013-08-20

    ... merging the metal halide lamp fixture and the high-intensity discharge (HID) lamp rulemakings. This NOPR... Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures; Proposed Rule #0;#0;Federal...: Energy Conservation Standards for Metal Halide Lamp Fixtures AGENCY: Office of Energy Efficiency and...

  13. Determination of mechanical properties of PVC foam using a modified Arcan fixture

    DEFF Research Database (Denmark)

    Taher, Siavash Talebi; Thomsen, Ole Thybo; M Dulieu-Barton, Janice

    2012-01-01

    of the fixture and misalignment of the fixture and loading machine are discussed. Thermoelastic stress analysis (TSA) is used to directly examine and validate the uniformity and symmetry of the stress fields obtained for both tensile and shear specimens. To account for the inhomogeneity of the strain field...... conducted using conventional test tensile and shear test fixtures.......The design and development of a modified Arcan fixture (MAF) is described. The purpose of the fixture is to characterize polymer foam materials with respect to their tensile, compressive, shear and bidirectional mechanical properties. The MAF enables the application of pure compression or high...

  14. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting on Lija Loop in Portland, OR

    International Nuclear Information System (INIS)

    Kinzey, Bruce R.; Myer, Michael

    2009-01-01

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, were achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.

  15. Experimental program of substitution of incandescent light bulb by circular and compact fluorescence lights in the residential sector; Programa experimental de substituicao de lampadas incandensentes por fluorescentes circulares e compactas no segmento residencial

    Energy Technology Data Exchange (ETDEWEB)

    Fugiwara, Jose Kozi; Campos Filho, Marcello de Moura [Companhia Paulista de Forca e Luz (CPFL), Campinas, SP (Brazil); Santos, Vanice Ferreira dos [Universidade Estadual de Campinas, SP (Brazil)

    1995-12-31

    This work discusses the influence of the residential sector in the Brazilian consumption of electric power and the importance of electric power conservation in residential illumination. A case study is presented. Finally, the perspectives for the utilization of this tool in electric power conservation for market planning is presented 1 tab., 6 refs.

  16. Integration of motor traffic in residential areas.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1977-01-01

    In stead of banning the cars from residential areas, the plan is to integrate them in such a way that they can still be used, but that they will loose their predominant position. The areas where this integration is to take place are called residential yards. This paper concentrates on the lighting

  17. Lighting Options for Homes.

    Energy Technology Data Exchange (ETDEWEB)

    Baker, W.S.

    1991-04-01

    This report covers many aspects of various lighting options for homes. Types of light sources described include natural light, artificial light, incandescent lamps, fluorescent lamps, and high intensity discharge lamps. A light source selection guide gives the physical characteristics of these, design considerations, and common applications. Color, strategies for efficient lighting, and types of lighting are discussed. There is one section giving tips for various situations in specific rooms. Rooms and types of fixtures are shown on a matrix with watts saved by using the recommended type lighting for that room and room location. A major emphasis of this report is saving energy by utilizing the most suitable, recommended lighting option. (BN)

  18. Residential greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    The following report examines the technical and economic viability of residential greenhouse additions in Whitehorse, Yukon. The greenhouse was constructed using the south facing wall of an existing residence as a common wall. Total construction costs were $18,000, including labour. Annual fuel demand for the residence has been reduced by about 10 per cent for an annual saving of $425. In addition, produce to the value of $1,000 is grown annually in the greenhouse for domestic consumption and commercial resale. Typically the greenhouse operates for nine months each year. There is a net thermal loss during the months of November, December and January as a result of the large area of glazing. As well as supplementing the heating supply solar greenhouses can provide additional cash crops which can be used to offset the cost of construction. Humidity problems are minimal and can be dealt with by exhausting high humidity air. One system which has been considered for the greenhouse is to use a standard residential heat pump to remove excess moisture and to pump heat into the house. This would have a secondary benefit of excluding the need to circulate greenhouse air through the house. Thus any allergenic reactions to the greenhouse air would be prevented. 8 refs., 3 figs, 2 tabs.

  19. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  20. TOOLS AND TECHNIQUES FOR IMPROVING THE MODULAR FIXTURE DESIGN IN AUTODESK INVENTOR

    Directory of Open Access Journals (Sweden)

    PĂUNESCU Rodica

    2015-06-01

    Full Text Available The paper presents some strategies achieving significant productivity gains in modular fixture design like: intelligent tools iParts, iAssembly, iProperties, Constraint and Joint, Interference, Relationships tools, working with subassemblies, using Autodesk Inventor new releases. Another objective is to minimize modular fixture systems databases and to optimize searching and inserting components. All this techniques and tools are exemplified by a modular fixture based on grid patterns with multipurpose holes.

  1. Concept of a Programmable Fixture for 3-Axis CNC

    Directory of Open Access Journals (Sweden)

    Ahmad Dalloul

    2017-09-01

    Full Text Available CNC machine is the one of the major reasons for industrial advancement in recent decades for its ability of producing accurate parts. The most commen CNC machines are of 3-axis and adopted widely in the industrial sector. However, for producing more complicated parts 5-axis CNC machines are required. Although the introduction of the 5-axis machine came after the 3-axis CNC machine has established itself and many manufacturers did not make the move toward the newer model and its high pricing compared to the 3-axis model did not help either. In this time the development of a fixture or a platform to help transfer the 3-axis to a 5-axis to some degree. This paper discusses the concept of a programmable fixture that gives 3-axis CNC machine the freedom to act in similar manner as the 5-axis. The paper describes the mechanism with some initial results of the testing. Result showed that the platform moves in translation manner with an average error of 5.58 % and 7.303% average error for rotation movement.

  2. Lighting

    Data.gov (United States)

    Federal Laboratory Consortium — Lighting Systems Test Facilities aid research that improves the energy efficiency of lighting systems. • Gonio-Photometer: Measures illuminance from each portion of...

  3. Abutment-to-fixture load transfer and peri-implant bone stress

    NARCIS (Netherlands)

    van Oers, R.F.; Feilzer, A.J.

    2015-01-01

    Purpose: To uncover design principles for the abutment-fixture complex that reduce the stress concentration on the bone. Methods: A 3-dimensional finite element model was used to vary shape, elasticity, and connectivity of the abutment-fixture complex. We compared peri-implant bone stress of these

  4. Light

    DEFF Research Database (Denmark)

    Prescott, N.B.; Kristensen, Helle Halkjær; Wathes, C.M.

    2004-01-01

    This chapter presents the effect of artificial light environments (light levels, colour, photoperiod and flicker) on the welfare of broilers in terms of vision, behaviour, lameness and mortality......This chapter presents the effect of artificial light environments (light levels, colour, photoperiod and flicker) on the welfare of broilers in terms of vision, behaviour, lameness and mortality...

  5. A Digital Interface for the Part Designers and the Fixture Designers for a Reconfigurable Assembly System

    Directory of Open Access Journals (Sweden)

    Vishwa V. Kumar

    2013-01-01

    Full Text Available This paper presents a web-based framework for interfacing product designers and fixture designers to fetch the benefits of early supplier involvement (ESI to a reconfigurable assembly system (RAS. The interfacing of the two members requires four steps, namely, collaboration chain, fixture supplier selection, knowledge share, and accommodation of service facilities so as to produce multiple products on a single assembly line. The interfacing not only provokes concurrency in the activities of product and fixture designer but also enables the assembly systems to tackle the spatial and generational variety. Among the four stages of interfacing, two steps are characterized by optimization issues, one from the product customer side and the other from the fixture designer side. To impart promptness in the optimization and hence the interaction, computationally economic tools are also presented in the paper for both of the supplier selection and fixture design optimization.

  6. Welding fixture for joining bar-wound stator conductors

    Science.gov (United States)

    De Souza, Urban J.; Rhoads, Frederick W.; Hanson, Justin

    2017-09-12

    A fixture assembly for welding a plurality of stator wire end pairs may include an anvil, a movable clamp configured to translate between an unclamped state and a clamped state, a first grounding electrode, and a second grounding electrode. The movable clamp may be configured to urge the plurality of stator wire ends against the anvil when in the clamped state. The moveable clamp includes a separator feature that generally extends toward the anvil. Each of the first grounding electrode and second grounding electrodes may be configured to translate between a clamped state and an unclamped state. When in the clamped state, each of the first and second grounding electrodes is configured to urge a pair of the plurality of stator wire end pairs against the separator feature.

  7. Interior LED Lighting Technology. Navy Energy Technology Validation (Techval) Program

    Science.gov (United States)

    2015-09-01

    usually on most of the time. • Consider replacing existing CFL, high-intensity discharge (HID), or halogen lamp light fixtures/ lamps with LED fixtures... lamps . What is the Technology? An LED is a semiconductor-diode that emits light when power is applied. A driver is used, much as a ballast, to...available in integrated luminaires that can be used to replace existing luminaires. LEDs are also available as direct replacement lamps for many

  8. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  9. Resultant geometric variation of a fixtured workpiece Part I: a simulation

    Directory of Open Access Journals (Sweden)

    Supapan Sangnui Chaiprapat

    2006-01-01

    Full Text Available When a workpiece is fixtured for a machining or inspection operation, the accuracy of an operation is mainly determined by the efficiency of the fixturing method. Variability in manufactured workpiece is hardly inevitable. When such variability is found at contact areas between the workpiece and the fixture, errors in location are expected. The errors will affect quality of features to be produced. This paper developed an algorithm to determine variant final locations of a displaced workpiece given normally distributed errorsat contact points. Resultant geometric variation of workpiece location reveals interesting information which is beneficial in tolerance planning.

  10. STAR Measurements and Modeling for Quantifying Air Quality and Climatic Impacts of Residential Biomass or Coal Combustion for Cooking, Heating and Lighting Kick-off Meeting

    Science.gov (United States)

    STAR grantees and EPA scientists will discuss progress on their projects which aim to quantify the extent to which interventions for cleaner cooking, heating, or lighting can impact air quality and climate, which in turn affect human health and welfare

  11. Text Fixture for Double Cantilever Beam (DCB) Specimens Subjected to Uneven Bending Moments

    DEFF Research Database (Denmark)

    Svenninggaard, Jon; Andreasen, Jens; Bak, Brian

    Bending Moments as a function of the phase angle ranging from mode I to mode II loading including mixed modes in-between. The test fixture utilizes an existing tensile testing machine and can subject specimens to loads up to 350 Nm. The test fixture is compact in size and designed using standard aluminium...... profiles for the main structure. The load is transferred from the test machine to the specimen through a 2 mm Dyneema rope. The rope is routed over a set of rollers that are positioned according to the specified mode mixity and phase angle. The kinematics of the test fixture has been analysed extensively...... strength in layered materials the cohesive law and fracture strength must be known. Ideally the entire cohesive law is known in order to aid in the design of components and structures. In this work we present a novel test fixture which can be used to test DCB specimens that are subjected to pure Uneven...

  12. Sensitivity analysis of dynamic characteristic of the fixture based on design variables

    International Nuclear Information System (INIS)

    Wang Dongsheng; Nong Shaoning; Zhang Sijian; Ren Wanfa

    2002-01-01

    The research on the sensitivity analysis is dealt with of structural natural frequencies to structural design parameters. A typical fixture for vibration test is designed. Using I-DEAS Finite Element programs, the sensitivity of its natural frequency to design parameters is analyzed by Matrix Perturbation Method. The research result shows that the sensitivity analysis is a fast and effective dynamic re-analysis method to dynamic design and parameters modification of complex structures such as fixtures

  13. Investigation into the effect of fixturing systems on the design of condition monitoring for machining operations

    OpenAIRE

    Abbas, JK

    2013-01-01

    The global market competition has drawn the manufacturer’s attention on automated manufacturing processes using condition monitoring systems. These systems have been used for improving product quality, eliminating inspection, and enhancing manufacturing productivity. Fixtures are essential devices in machining processes to hold the tool or workpiece, hence they are influenced directly by the stability of the cutting tool. Therefore, tool and fixturing faults play an important part in the inac...

  14. Using Bonding Enamel-Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures

    Science.gov (United States)

    2010-02-01

    Initial tests with enameled metal straps cracked all the test cylinders and straps would not pull out BUILDING STRONG® New Strong Durable Ties...BUILDING STRONG® Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures Principal Investigator: Steven C...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry

  15. Light

    CERN Document Server

    Robertson, William C

    2003-01-01

    Why is left right and right left in the mirror? Baffled by the basics of reflection and refraction? Wondering just how the eye works? If you have trouble teaching concepts about light that you don t fully grasp yourself, get help from a book that s both scientifically accurate and entertaining with Light. By combining clear explanations, clever drawings, and activities that use easy-to-find materials, this book covers what science teachers and parents need to know to teach about light with confidence. It uses ray, wave, and particle models of light to explain the basics of reflection and refraction, optical instruments, polarization of light, and interference and diffraction. There s also an entire chapter on how the eye works. Each chapter ends with a Summary and Applications section that reinforces concepts with everyday examples. Whether you need a deeper understanding of how light bends or a good explanation of why the sky is blue, you ll find Light more illuminating and accessible than a college textbook...

  16. Lighting. Eclairage

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Increasing energy costs have led to a review of the high costs of lighting. The use of new energy-efficient lighting equipment, coupled with the use of the proper quantity and quality of lighting only where it is needed, creates a potential for cost reduction. A manual is provided to aid the process of adapting Canadian industrial, commercial, and institutional enterprises to these higher costs. An introductory review of lighting fundamentals is presented, providing a basic understanding of concepts such as illumination, light output measurements, power requirements, lighting quality, and energy audit methods. The currently available lighting equipment used to achieve cost savings is then reviewed, including energy saving lamps and ballasts, controls, and automatic energy control systems. A number of energy management opportunities are identified, such as modification of lighting usage patterns, calculation of the optimum number of lighting fixtures, replacement of existing lamps, and the application of task lighting. Examples are included to show the cost savings possible when applying some of the techniques suggested. 27 figs., 11 tabs.

  17. Shear punch tests performed using a new low compliance test fixture

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Kurtz, R.J.; Hasegawa, A.; Abe, K.

    2002-01-01

    Based on a recent finite element analysis (FEA) study performed on the shear punch test technique, it was suggested that compliance in a test frame and fixturing which is quite acceptable for uniaxial tensile tests, is much too large for shear punch tests. The FEA study suggested that this relatively large compliance was masking both the true yield point and the shape of the load versus displacement trace obtained in shear punch tests. The knowledge gained from the FEA study was used to design a new shear punch test fixture which more directly measures punch tip displacement. The design of this fixture, the traces obtained from this fixture, and the correlation between uniaxial yield stress and shear yield stress obtained using this fixture are presented here. In general, traces obtained from the new fixture contain much less compliance resulting in a trace shape which is more similar in appearance to a corresponding uniaxial tensile trace. Due to the more direct measurement of displacement, it was possible to measure yield stress at an offset shear strain in a manner analogous to yield stress measurement in a uniaxial tensile test. The correlation between shear yield and uniaxial yield was altered by this new yield measurement technique, but the new correlation was not as greatly improved as was suggested would occur from the FEA study

  18. Determination of the Number of Fixture Locating Points for Sheet Metal By Grey Model

    Directory of Open Access Journals (Sweden)

    Yang Bo

    2017-01-01

    Full Text Available In the process of the traditional fixture design for sheet metal part based on the "N-2-1" locating principle, the number of fixture locating points is determined by trial and error or the experience of the designer. To that end, a new design method based on grey theory is proposed to determine the number of sheet metal fixture locating points in this paper. Firstly, the training sample set is generated by Latin hypercube sampling (LHS and finite element analysis (FEA. Secondly, the GM(1, 1 grey model is constructed based on the established training sample set to approximate the mapping relationship between the number of fixture locating points and the concerned sheet metal maximum deformation. Thirdly, the final number of fixture locating points for sheet metal can be inversely calculated under the allowable maximum deformation. Finally, a sheet metal case is conducted and the results indicate that the proposed approach is effective and efficient in determining the number of fixture locating points for sheet metal.

  19. Multiobjective Optimization for Fixture Locating Layout of Sheet Metal Part Using SVR and NSGA-II

    Directory of Open Access Journals (Sweden)

    Yuan Yang

    2017-01-01

    Full Text Available Fixture plays a significant role in determining the sheet metal part (SMP spatial position and restraining its excessive deformation in many manufacturing operations. However, it is still a difficult task to design and optimize SMP fixture locating layout at present because there exist multiple conflicting objectives and excessive computational cost of finite element analysis (FEA during the optimization process. To this end, a new multiobjective optimization method for SMP fixture locating layout is proposed in this paper based on the support vector regression (SVR surrogate model and the elitist nondominated sorting genetic algorithm (NSGA-II. By using ABAQUS™ Python script interface, a parametric FEA model is established. And the fixture locating layout is treated as design variables, while the overall deformation and maximum deformation of SMP under external forces are as the multiple objective functions. First, a limited number of training and testing samples are generated by combining Latin hypercube design (LHD with FEA. Second, two SVR prediction models corresponding to the multiple objectives are established by learning from the limited training samples and are integrated as the multiobjective optimization surrogate model. Third, NSGA-II is applied to determine the Pareto optimal solutions of SMP fixture locating layout. Finally, a multiobjective optimization for fixture locating layout of an aircraft fuselage skin case is conducted to illustrate and verify the proposed method.

  20. Questions asked concerning energy savings in lighting systems

    International Nuclear Information System (INIS)

    Bernet, J.

    2005-01-01

    This article discusses the question why information on the power consumption of lighting fixtures is not often to be found in articles in lifestyle magazines or in the displays of designer-boutiques. The efficiency of various types of lighting is discussed. In particular, the differences between traditional incandescent bulbs and energy-saving lighting systems are examined from the aesthetical, colour-reproduction and energy-consumption points of view. Further information presented includes details on colour-reproduction indexes and colour temperature. The lighting needs of various types of room are looked at and the influence of the physical form of the lighting fixtures on purchasing decisions is examined

  1. Light

    CERN Document Server

    Ditchburn, R W

    1963-01-01

    This classic study, available for the first time in paperback, clearly demonstrates how quantum theory is a natural development of wave theory, and how these two theories, once thought to be irreconcilable, together comprise a single valid theory of light. Aimed at students with an intermediate-level knowledge of physics, the book first offers a historical introduction to the subject, then covers topics such as wave theory, interference, diffraction, Huygens' Principle, Fermat's Principle, and the accuracy of optical measurements. Additional topics include the velocity of light, relativistic o

  2. Fifth Interim Status Report: Model 9975 PCV O-Ring Fixture Long-Term Leak Performance

    International Nuclear Information System (INIS)

    Daugherty, W.; Hoffman, E.

    2010-01-01

    A series of experiments to monitor the aging performance of Viton reg. GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service

  3. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  4. Comprehensive analysis of the mechanical system system “fixture – workpiece”

    Directory of Open Access Journals (Sweden)

    V. Ivanov

    2017-05-01

    Full Text Available Present work is devoted to locating and clamping of prismatic parts in fixtures during the machining on drilling-milling-boring machines. The special feature of locating schemes of parts of the present type is that one of the flat surfaces is used as a datum (3 contact points ensuring stability, convenience of locating and vibration elimination during the machining process. Within the scope of the presented work, the comprehensive mathematical model of the system “fixture – workpiece” has been developed taking into account technological features of locating and clamping processes of workpiece in fixture. The methodology of determination of the rigidity of the cutting tool and functional elements has been proposed. As a result, the static and dynamic analysis of the workpiece in the fixture under the effect of spatial system of cutting and clamping forces is being determined. In addition, the free frequencies of the system “fixture-workpiece” and forms of the free and forced vibrations, frequency-response characteristics are being determined. Keywords: locating chart, functional element, rigidity, free vibrations, free frequency, forced vibrations, cutting force, frequency-response characteristic

  5. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    Science.gov (United States)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  6. Non-imaging optics for LED-lighting

    NARCIS (Netherlands)

    Berg, van den J.B.; Castro, R.M.; Draisma, J.; Evers, J.H.M.; Hendriks, M.; Krehel, O.; Kryven, I.; Mora, K.; Szabó, B.T.; Zwiernik, P.W.; Boon, M.A.A.

    2013-01-01

    In this report, several methods are investigated to rapidly compute the light intensity function, either in the far field or on a finite-distance screen, of light emanating from a light fixture with a given shape. Different shapes are considered, namely polygonal and (piecewise) smooth. In the first

  7. Energy conservation in two wheeler head tube welding fixture by modeling

    Science.gov (United States)

    Kamalanathan, S.; Guruprasad, B.; Elango, A.

    2018-05-01

    Energy conservation in automotive industry plays a significant role to increase the productivity which reduces the Men, Material, and Machinery. The Automotive industry sector is one of the major sector which works in two or more times of loading of work pieces in welding fixture. It consumes more energy. This project focuses on reduce the energy consumption by applying single time loading of work pieces with minimum number of labours, machine and reduces scrap. Welding fixtures are designed for the components which are difficult to weld in normal way or without any holding unit. The fixture is to be designed for the two wheeler head tube assembly which is to be welded with its companion for its application. It is demonstrated by modelling in Uni-graphics Software and FEA analysis will be done by ANSYS and experimentally products are tested and execute in industry. A code of practice suggested establishing acceptable standard for energy used in Automotive industry.

  8. Effect of target-fixture geometry on shock-wave compacted copper powders

    Science.gov (United States)

    Kim, Wooyeol; Ahn, Dong-Hyun; Yoon, Jae Ik; Park, Lee Ju; Kim, Hyoung Seop

    2018-01-01

    In shock compaction with a single gas gun system, a target fixture is used to safely recover a powder compact processed by shock-wave dynamic impact. However, no standard fixture geometry exists, and its effect on the processed compact is not well studied. In this study, two types of fixture are used for the dynamic compaction of hydrogen-reduced copper powders, and the mechanical properties and microstructures are investigated using the Vickers microhardness test and electron backscatter diffraction, respectively. With the assistance of finite element method simulations, we analyze several shock parameters that are experimentally hard to control. The results of the simulations indicate that the target geometry clearly affects the characteristics of incident and reflected shock waves. The hardness distribution and the microstructure of the compacts also show their dependence on the geometry. With the results of the simulations and the experiment, it is concluded that the target geometry affects the shock wave propagation and wave interaction in the specimen.

  9. Bandwidth increasing mechanism by introducing a curve fixture to the cantilever generator

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Weiqun, E-mail: weiqunliu@home.swjtu.edu.cn; Liu, Congzhi; Ren, Bingyu; Zhu, Qiao; Hu, Guangdi [School of Mechanical Engineering, Southwest Jiaotong University, 610031 Chengdu (China); Yang, Weiqing [School of Materials Science and Engineering, Southwest Jiaotong University, 610031 Chengdu (China)

    2016-07-25

    A nonlinear wideband generator architecture by clamping the cantilever beam generator with a curve fixture is proposed. Devices with different nonlinear stiffness can be obtained by properly choosing the fixture curve according to the design requirements. Three available generator types are presented and discussed for polynomial curves. Experimental investigations show that the proposed mechanism effectively extends the operation bandwidth with good power performance. Especially, the simplicity and easy feasibility allow the mechanism to be widely applied for vibration generators in different scales and environments.

  10. Gentrification and Residential Mobility in Philadelphia.

    Science.gov (United States)

    Ding, Lei; Hwang, Jackelyn; Divringi, Eileen

    2016-11-01

    Gentrification has provoked considerable controversy surrounding its effects on residential displacement. Using a unique individual-level, longitudinal data set, this study examines mobility rates and residential destinations of residents in gentrifying neighborhoods during the recent housing boom and bust in Philadelphia for various strata of residents and different types of gentrification. We find that vulnerable residents, those with low credit scores and without mortgages, are generally no more likely to move from gentrifying neighborhoods compared with their counterparts in nongentrifying neighborhoods. When they do move, however, they are more likely to move to lower-income neighborhoods. Residents in gentrifying neighborhoods at the aggregate level have slightly higher mobility rates, but these rates are largely driven by more advantaged residents. These findings shed new light on the heterogeneity in mobility patterns across residents in gentrifying neighborhoods and suggest that researchers should focus more attention on the quality of residential moves and nonmoves for less advantaged residents, rather than mobility rates alone.

  11. FY2017 status report: Model 9975 O-ring fixture long-term leak performance

    Energy Technology Data Exchange (ETDEWEB)

    Daugherty, W. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-27

    A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results

  12. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  13. SHIVA Nd: glass disk-amplifier-assembly facility and special purpose fixtures

    International Nuclear Information System (INIS)

    Jones, W.A.; Patton, H.G.; Stowers, I.F.; Wentworth, D.E.

    1977-09-01

    The facility built to assemble and maintain the laser amplifiers in the SHIVA Laser System is described. The facility is a Class-100 clean room which includes a high pressure solvent spray box, optical inspection equipment, and several unique amplifier-assembly fixtures

  14. Accuracy of Setting Work-pieces on Automatic Lines with Pallet-fixtures

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2015-01-01

    Full Text Available The accuracy of positioning surfaces to be processed on automatic lines with pallet-fixtures essentially depends on the setting error of the pallet-fixtures with work-pieces in ready-to-work position.The applied methods for calculating the setting error do not give a complete picture of the possible coordinates of the point when in the pallet is displaced in different directions.The aim of the work was to determine an accuracy of the setting work-pieces on automatic lines with pallets-fixtures, using a computational and analytical method, to improve a manufacturing precision of parts.The currently used methods to calculate the setting error do not give a complete picture of the possible coordinates of the point of the pallet displacement in different directions. The paper offers a method of equivalent mechanism to determine all the variety of options for displacements in the horizontal plane with a diverse combination of angular and plane-parallel displacements.Using a four-bar linkage, as an equivalent mechanism, allows us to define a zone of the possible positions of any point of the work-piece pallet platform, as the zone bounded by the coupler curve. In case the gaps in the nodes of the two fixtures are equal the zone of possible positions of the point in the parallel displacement of the platform is determined by the circumference and at an angular displacement by the ellipse.The obtained analytical dependences allow us to determine the error at the stage of design with the certain gaps in the fixture nodes.The above method of calculation makes it possible to define a zone of the appropriate placement of the work-piece on its platform for the specified parameters of the pallet to meet conditions for ensuring the coordinate accuracy of the processed axes of holes.

  15. User's manual for remote-handled transuranic waste container welding and inspection fixture

    International Nuclear Information System (INIS)

    Hauptmann, J.P.

    1985-09-01

    Rockwell Hanford Operations (Rockwell) has designed built, and tested a prototype remotely operated welding and inspection fixture to be used in making the closure weld on the remote-handled transuranic (RH-TRU) waste container. The RH-TRU waste container has an average TRU concentration in excess of 100 nCi/gm, and a surface radiation dose rate in excess of 200 mrem/h, but not exceeding 100 rem/h. The RH-TRU waste container is to be used by defense waste generator sites in the United States for final packaging of RH-TRU wastes and is compatible with the requirements of the Waste Isolation Pilot Plant (WIPP) and the WIPP handling system. Standard and stacked RH-TRU container designs are available. The standard container is 26 in. in dia. by 121 in. high; the stacked containers are 26 in. in dia. by 61.25 in. high. After loading, two stacked containers are fitted and welded together to form the identical measurements of the standard 121-in. container. The prototype RH-TRU waste container welding and inspection fixture was intended for test and evaluation only, and not for installation in an operating facility. The final RH-TRU waste container welding and inspection fixture drawings (see appendix) incorporate several changes made following operational testing of the original fixture. These modifications are identified in this manual. However, not all modifications have been functionally tested. The purpose of this manual is to aid waste generator sites in designing a remotely operated welding and inspection fixture that will conform to their own requirements. Modifications to the Rockwell design must be evaluated for structural and WIPP handling requirements. This manual also provides design philosophy, component vendor information, and cost estimates

  16. Family ties and residential locations

    NARCIS (Netherlands)

    Mulder, C.H.; Cooke, T.J.

    2009-01-01

    In this paper, and in the Special Issue it introduces, the focus is on the role of family ties in residential location choice and, conversely, the role of residential locations in maintaining family ties. Not only do events in the nuclear family trigger residential relocations, but nearby family

  17. GREEN RETROFITTING RESIDENTIAL BUILDINGS

    Science.gov (United States)

    When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...

  18. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, a. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2014-12-01

    This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

  19. Towards a bright future? Household use of electric light: A microlevel study

    International Nuclear Information System (INIS)

    Bladh, Mats; Krantz, Helena

    2008-01-01

    This paper addresses the problem of energy saving in the residential sector and its relation to behavior. However, we know little about the mechanisms explaining consumption and use. The aim is to explore the behavioral elements behind patterns of use, so that consumption can be explained and saving possibilities identified. The study is based on detailed, metered data from an ongoing monitoring study. A larger sample from that study made testing of two hypotheses possible. Yet, many factors remain hidden and must be traced among the habits of households. The major part of the article is devoted to an exploration into what other variables are at work. This was done by studying the electricity consumption of seven households closely. Here, different sources of information from each household were combined: detailed, metered data for each lamp or fixture; data from interviews regarding habits; and observations of natural light and lighting equipment at visits. This information from combined sources was used to detect meanings of use and relationships with consumption. What has been found here must be translated to measurable variables and tested on representative samples of populations. This study offers information on these variables identified and how to interpret them

  20. Development of a Prediction Model Based on RBF Neural Network for Sheet Metal Fixture Locating Layout Design and Optimization.

    Science.gov (United States)

    Wang, Zhongqi; Yang, Bo; Kang, Yonggang; Yang, Yuan

    2016-01-01

    Fixture plays an important part in constraining excessive sheet metal part deformation at machining, assembly, and measuring stages during the whole manufacturing process. However, it is still a difficult and nontrivial task to design and optimize sheet metal fixture locating layout at present because there is always no direct and explicit expression describing sheet metal fixture locating layout and responding deformation. To that end, an RBF neural network prediction model is proposed in this paper to assist design and optimization of sheet metal fixture locating layout. The RBF neural network model is constructed by training data set selected by uniform sampling and finite element simulation analysis. Finally, a case study is conducted to verify the proposed method.

  1. Development of a Prediction Model Based on RBF Neural Network for Sheet Metal Fixture Locating Layout Design and Optimization

    Directory of Open Access Journals (Sweden)

    Zhongqi Wang

    2016-01-01

    Full Text Available Fixture plays an important part in constraining excessive sheet metal part deformation at machining, assembly, and measuring stages during the whole manufacturing process. However, it is still a difficult and nontrivial task to design and optimize sheet metal fixture locating layout at present because there is always no direct and explicit expression describing sheet metal fixture locating layout and responding deformation. To that end, an RBF neural network prediction model is proposed in this paper to assist design and optimization of sheet metal fixture locating layout. The RBF neural network model is constructed by training data set selected by uniform sampling and finite element simulation analysis. Finally, a case study is conducted to verify the proposed method.

  2. Quantifying and Reducing Light Pollution

    Science.gov (United States)

    Gokhale, Vayujeet; Caples, David; Goins, Jordan; Herdman, Ashley; Pankey, Steven; Wren, Emily

    2018-06-01

    We describe the current level of light pollution in and around Kirksville, Missouri and around Anderson Mesa near Flagstaff, Arizona. We quantify the amount of light that is projected up towards the sky, instead of the ground, using Unihedron sky quality meters installed at various locations. We also present results from DSLR photometry of several standard stars, and compare the photometric quality of the data collected at locations with varying levels of light pollution. Presently, light fixture shields and ‘warm-colored’ lights are being installed on Truman State University’s campus in order to reduce light pollution. We discuss the experimental procedure we use to test the effectiveness of the different light fixtures shields in a controlled setting inside the Del and Norma Robison Planetarium.Apart from negatively affecting the quality of the night sky for astronomers, light pollution adversely affects migratory patterns of some animals and sleep-patterns in humans, increases our carbon footprint, and wastes resources and money. This problem threatens to get particularly acute with the increasing use of outdoor LED lamps. We conclude with a call to action to all professional and amateur astronomers to act against the growing nuisance of light pollution.

  3. Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

    OpenAIRE

    Chang, Glenn Hsuan-Chen; Tian, Chen; Hung, Yuen-Siang

    2011-01-01

    Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately lo...

  4. Racetrack coil instability resulting from friction-heat generation at fixtures

    International Nuclear Information System (INIS)

    Yazawa, T.; Urata, M.; Chandratilleke, G.R.; Maeda, H.

    1993-01-01

    This paper describes racetrack coil instability resulting from friction-heat generation at fixtures and a preventive measure against it using a thermal barrier. Epoxy impregnated racetrack coils sometimes experience premature quenches due to frictional heat produced by coil slides at fixtures that are essential for the coil straight part to withstand the electromagnetic force. Experimentally, we confirmed for a small-sized racetrack coil that coil slides were actually occurring. The coil movements coupled with acoustic emissions were observed several times when the coil was energized. Each of them was about 10 μm, an equivalent of 20 mJ in frictional heat. This frictional heat was almost comparable with the analytical and experimental coil stability margins when an insulation layer was thin. One of the effective measures against the frictional heat is the thermal barrier, which is a thick insulation layer at the interface between the coil and the fixtures. By thickening the insulation layer from 0.36 to 1.00 mm, the coil stability margin increased from 100 to 200 mJ. (orig.)

  5. Design, development and testing of a high speed door for a blast containment fixture

    International Nuclear Information System (INIS)

    Shapiro, C.

    1991-01-01

    This paper reports that the concept of a large door able to close over a three foot diameter hole in less than 50 milliseconds evolved during the design of a test containment fixture at the Idaho National Engineering laboratory (INEL). This facility was designed for use at the Aberdeen Proving Ground (APG) in Aberdeen, Maryland. EPA regulations required new technologies for blast containment at APG, which culminated in the design of the blast chamber with a high speed door at its entrance. The main requirement of the fixture is to contain large explosion pressure pulses and explosive by-products during a variety of test scenarios. The door was designed to allow entrance of test projectiles and then to close over the entrance hole to contain explosive by-products inside the fixture. The speed of the projectile and the resultant blast pressure pulse required door closure within 56 msec. Analytical modelling of the door closure indicated velocities of up to 150 ft/sec before impact, for closure within the required time. Lightweight materials were used for the moving parts to minimize this impact force, including aluminum honeycomb composite panels and energy absorbers. Actuation was accomplished with a standard explosive bolt. High pressure nitrogen accelerated the door during closure. Time measurement for the door closer were obtained using high speed video equipment

  6. Lighting performance and electrical energy consumption of a virtual window prototype

    NARCIS (Netherlands)

    Mangkuto, R.A.; Wang, S.; Meerbeek, B.W.; Aries, M.B.C.; Loenen, van E.J.

    2014-01-01

    This article discusses the design and evaluation of a virtual window prototype, built using arrays of LED tiles to simulate the light as well as the view of a window. Arrays of white light LED fixtures with adjustable colour temperatures were incorporated to provide direct light into the test room.

  7. Guidelines for residential commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

    2003-01-31

    Currently, houses do not perform optimally or even as many codes and forecasts predict, largely because they are field assembled and there is no consistent process to identify problems or to correct them. Residential commissioning is a solution to this problem. This guide is the culmination of a 30-month project that began in September 1999. The ultimate objective of the project is to increase the number of houses that undergo commissioning, which will improve the quality, comfort, and safety of homes for California citizens. The project goal is to lay the groundwork for a residential commissioning industry in California focused on end-use energy and non-energy issues. As such, we intend this guide to be a beginning and not an end. Our intent is that the guide will lead to the programmatic integration of commissioning with other building industry processes, which in turn will provide more value to a single site visit for people such as home energy auditors and raters, home inspectors, and building performance contractors. Project work to support the development of this guide includes: a literature review and annotated bibliography, which facilitates access to 469 documents related to residential commissioning published over the past 20 years (Wray et al. 2000), an analysis of the potential benefits one can realistically expect from commissioning new and existing California houses (Matson et al. 2002), and an assessment of 107 diagnostic tools for evaluating residential commissioning metrics (Wray et al. 2002). In this guide, we describe the issues that non-experts should consider in developing a commissioning program to achieve the benefits we have identified. We do this by providing specific recommendations about: how to structure the commissioning process, which diagnostics to use, and how to use them to commission new and existing houses. Using examples, we also demonstrate the potential benefits of applying the recommended whole-house commissioning approach to

  8. Rain Sensor with Stacked Light Waveguide Having Tilted Air Gap

    Directory of Open Access Journals (Sweden)

    Kyoo Nam Choi

    2014-01-01

    Full Text Available Vehicle sensor to detect rain drop on and above waveguide utilizing light deflection and scattering was realized, keeping wide sensing coverage and sensitivity to detect mist accumulation. Proposed sensor structure under stacked light wave guide consisted of light blocking fixture surrounding photodetector and adjacent light source. Tilted air gap between stacked light waveguide and light blocking fixture played major role to increase sensitivity and to enhance linearity. This sensor structure eliminated complex collimating optics, while keeping wide sensing coverage using simple geometry. Detection algorithm based on time-to-intensity transformation process was used to convert raining intensity into countable raining process. Experimental result inside simulated rain chamber showed distinct different response between light rain and normal rain. Application as automobile rain sensor is expected.

  9. Are physical performance and injury risk in a professional soccer team in match-play affected over a prolonged period of fixture congestion?

    Science.gov (United States)

    Carling, C; Le Gall, F; Dupont, G

    2012-01-01

    In this study, the effects of a prolonged period of fixture congestion (8 successive official matches in 26 days) on physical performance and injury risk and severity in a professional soccer team were investigated. Computerised motion-analysis was used to analyse the overall distance covered and that run at light- (0.0-11.0 km·h - 1); low- (11.1-14.0 km·h - 1); moderate- (14.1-19.7 km·h - 1) and high-intensities (≥19.8 km·h - 1) for the team as a whole. Distances were measured in metres per minute. Information on match injuries was recorded prospectively. The overall distance covered varied across successive matches (pvs. 116.0 ± 8.0 m·min - 1 and 115.5 ± 11.0 m·min - 1). Distance run in light-intensity exercise also varied (pvs. 1, 2, 3, 5 and 6 (75.5 ± 3.8 m·min - 1 vs. 70.6 ± 2.4 m·min - 1, 71.8 ± 3.4 m·min - 1, 69.3 ± 2.6 m·min - 1, 71.5 ± 3.1 m·min - 1, and 70.3 ± 2.8 m·min - 1) and in game 8 vs. game 3 (73.1 ± 3.8 vs. 69.3 ± 2.6 m·min - 1), respectively. When comparing match halves, there were no differences across games in overall or high-intensity distance covered and performance in these measures was similar for matches played before, during and after this period. Globally, no difference over the 8 games combined was observed between the reference team and opponents in any of the performance measures whereas the overall distance covered and that in low- (both pindividual games. The incidence of match injury during the congested fixture period was similar to rates reported outside this period but the mean lay-off duration of injuries was substantially shorter during the former (p<0.05). In summary, while the overall distance run and that covered at lower intensities varied across games, high-intensity running performance and injury risk were generally unaffected during a prolonged period of fixture congestion. These results might be linked to squad rotation and post-match recovery

  10. Downtown Detroit Energy Efficient Street Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Goodwin, Malik [Detroit Economic Growth Corp, Detroit, MI (United States)

    2013-11-29

    Reliable public lighting remains a critically important and valuable public service in Detroit, Michigan. The Downtown Detroit Energy Efficiency Lighting Program (the, “Program”) was designed and implemented to bring the latest advancements in lighting technology, energy efficiency, public safety and reliability to Detroit’s Central Business District, and the Program accomplished those goals successfully. Downtown’s nighttime atmosphere has been upgraded as a result of the installation of over 1000 new LED roadway lighting fixtures that were installed as part of the Program. The reliability of the lighting system has also improved.

  11. Study of performance of acoustic fixture for using in noise reduction rate tests of hearing protection devices

    Directory of Open Access Journals (Sweden)

    zam Biabani

    2016-06-01

    Full Text Available Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates of five common ear muffs used in the Iran industries were investigated based on the ISO 11904 standard, microphone in real ear method, using noise dosimeter (SVANTEK , Model SV102 equipped with microphone SV25 model which can install inside the ear on 30 subjects under laboratory conditions. Also, noise reduction rate of earmuffs was determined using the fixture model AVASINA9402 accordance with standard procedures. Data were analyzed using the software SPSS21. Results: The results showed the real noise reduction rates of the earmuffs on the studied subjects are from 59% to 94% nominal reduction rates. That rates for the ear muffs on the studied fixture are from 64% to 92.The results showed that the noise reduction rates of the ear muffs on subjects compared with and noise reduction rates of the ear muffs on fixture were not statistically significant (p> 0.05. Conclusion: The results showed the accuracy of noise reduction rate of earmuffs using the fixture compared with real subjects is acceptable. Hence, the fixture is good choice for environments where there’s no possibility of acoustic evaluation on real subjects, also for quality control of productions in the earmuff manufacturers.

  12. Re-thinking residential mobility

    Science.gov (United States)

    van Ham, Maarten; Findlay, Allan M.

    2015-01-01

    While researchers are increasingly re-conceptualizing international migration, far less attention has been devoted to re-thinking short-distance residential mobility and immobility. In this paper we harness the life course approach to propose a new conceptual framework for residential mobility research. We contend that residential mobility and immobility should be re-conceptualized as relational practices that link lives through time and space while connecting people to structural conditions. Re-thinking and re-assessing residential mobility by exploiting new developments in longitudinal analysis will allow geographers to understand, critique and address pressing societal challenges. PMID:27330243

  13. Large-Scale Residential Demolition

    Science.gov (United States)

    The EPA provides resources for handling residential demolitions or renovations. This includes planning, handling harmful materials, recycling, funding, compliance assistance, good practices and regulations.

  14. Design, fabrication, and initial test of a fixture for reducing the natural frequency of the Mod-O wind turbine tower

    Science.gov (United States)

    Winemiller, J. R.; Sullivan, T. L.; Sizemore, R. L.; Yee, S. T.

    1979-01-01

    It was desired to observe the behavior of a two bladed wind turbine where the tower first bending natural frequency is less than twice the rotor speed. The system then passes through resonance when accelerating to operating speed. The frequency of the original Mod-O tower was reduced by placing it on a spring fixture. The fixture is adjustable to provide a range of tower bending frequencies. Fixture design details are given and behavior during initial operation is described.

  15. Development, production and promotion of energy-saving and environmentally correct fixtures for private homes; Udvikling, produktion of markedsfoering af energi- og miljoerigtige armaturer til boligmarkedet

    Energy Technology Data Exchange (ETDEWEB)

    Velk, A.; Munck, K. [Lysteknisk Selskab (Denmark)

    2006-08-31

    A design competition for environmentally correct and energy-saving fixtures for private homes was arranged in 2004. There were 88 entries and three were awarded with a prize. The purpose of the project was to produce and promote two or three proposals in a campaign for the use of environmentally correct and energy-saving fixtures. Three manufacturers of fixtures had given prior notice that they would produce the fixtures, but with certain conditions. Despite the many entries, the manufacturers assessed that none of them possessed the necessary qualities to commence product development. A group of designers were offered the possibility to find other manufacturers, but they did not succeed. (au)

  16. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  17. Dimensional Metrology of Non-rigid Parts Without Specialized Inspection Fixtures =

    Science.gov (United States)

    Sabri, Vahid

    Quality control is an important factor for manufacturing companies looking to prosper in an era of globalization, market pressures and technological advances. Functionality and product quality cannot be guaranteed without this important aspect. Manufactured parts have deviations from their nominal (CAD) shape caused by the manufacturing process. Thus, geometric inspection is a very important element in the quality control of mechanical parts. We will focus here on the geometric inspection of non-rigid (flexible) parts which are widely used in the aeronautic and automotive industries. Non-rigid parts can have different forms in a free-state condition compared with their nominal models due to residual stress and gravity loads. To solve this problem, dedicated inspection fixtures are generally used in industry to compensate for the displacement of such parts for simulating the use state in order to perform geometric inspections. These fixtures and the installation and inspection processes are expensive and time-consuming. Our aim in this thesis is therefore to develop an inspection method which eliminates the need for specialized fixtures. This is done by acquiring a point cloud from the part in a free-state condition using a contactless measuring device such as optical scanning and comparing it with the CAD model for the deviation identification. Using a non-rigid registration method and finite element analysis, we numerically inspect the profile of a non-rigid part. To do so, a simulated displacement is performed using an improved definition of displacement boundary conditions for simulating unfixed parts. In addition, we propose a numerical method for dimensional metrology of non-rigid parts in a free-state condition based on the arc length measurement by calculating the geodesic distance using the Fast Marching Method (FMM). In this thesis, we apply our developed methods on industrial non-rigid parts with free-form surfaces simulated with different types of

  18. Interim design status and operational report for remote handling fixtures: primary and secondary burners

    International Nuclear Information System (INIS)

    Burgoyne, R.M.

    1976-12-01

    The HTGR reprocessing flowsheet consists of two basic process elements: (1) spent fuel crushing and burning and (2) solvent extraction. Fundamental to these elements is the design and development of specialized process equipment and support facilities. A major consideration of this design and development program is equipment maintenance: specifically, the design and demonstration of selected remote maintenance capabilities and the integration of these into process equipment design. This report documents the current status of the development of remote handling and maintenance fixtures for the primary and secondary burners

  19. Reusable locking tube insertion and removal fixture and method in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a locking tube insertion and removal fixture for use with a reconstitutable fuel assembly. The process includes a top nozzle with an adapter plate having at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having a hollow locking tube insertable and removable into and from a locking position in the upper end portion of the guide thimble for releasably locking the upper end portion of the guide thimble within the passageway of the top nozzle and adapter plate

  20. Characterization of Compressive Properties of Polymer Foam Materials Using DIC and a Modified Arcan Fixture

    DEFF Research Database (Denmark)

    Taher, Siavash Talebi; Thomsen, Ole Thybo; Dulieu-Barton, J. M.

    2013-01-01

    bidirectional loading conditions that are not possible with conventional Arcan fixtures. The MAF is attached to a standard universal test machine, equiped with an environmental chamber, using specially designed grips that do not constrain the specimen wrt. rotations, and hence reduces paristic effects due......, a “correction factor” for the measured surface strain is determined using nonlinear finite element analysis (FEA). The paper will focus on the characterization of the compressive material properties including the MAF setup, test specimen design, experimental procedure and validated experimental results....

  1. Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

    Directory of Open Access Journals (Sweden)

    Glenn Hsuan-Chen Chang

    2011-01-01

    Full Text Available Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment.

  2. Mammography fixture

    International Nuclear Information System (INIS)

    Henkes, J.L. Jr.

    1979-01-01

    A device is described for compressing a pendant breast during tomographic mammography using X-rays. The device utilises a thin, elastic membrane pressurised by a fluid whose X-ray absorption properties are similar to those of soft human tissue. The membrane changes the normal conical shape of a pendant breast into a substantially cylindrical shape. The breast is surrounded by a second fluid medium whose X-ray absorption properties are also similar to that of soft human tissue and tomography transmission is carried out through the second fluid medium and the breast. This patent claims the advantages of eliminating high gradients in X-ray absorption density and the effective detection of breast tumours with minimum radiation dosage and processing time. (UK)

  3. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  4. Residential energy demand in Brazil

    International Nuclear Information System (INIS)

    Arouca, M.; Gomes, F.M.; Rosa, L.P.

    1981-01-01

    The energy demand in Brazilian residential sector is studied, discussing the methodology for analyzing this demand from some ideas suggested, for developing an adequate method to brazilian characteristics. The residential energy consumption of several fuels in Brazil is also presented, including a comparative evaluation with the United States and France. (author)

  5. Costs of day hospital and community residential chemical dependency treatment.

    Science.gov (United States)

    Kaskutas, Lee Ann; Zavala, Silvana K; Parthasarathy, Sujaya; Witbrodt, Jane

    2008-03-01

    Patient placement criteria developed by the American Society of Addiction Medicine (ASAM) have identified a need for low-intensity residential treatment as an alternative to day hospital for patients with higher levels of severity. A recent clinical trial found similar outcomes at social model residential treatment and clinically-oriented day hospital programs, but did not report on costs. This paper addresses whether the similar outcomes in the recent trial were delivered with comparable costs, overall and within gender and ethnicity stratum. This paper reports on clients not at environmental risk who participated in a randomized trial conducted in three metropolitan areas served by a large pre-paid health plan. Cost data were collected using the Drug Abuse Treatment Cost Analysis Program (DATCAP). Costs per episode were calculated by multiplying DATCAP-derived program-specific costs by each client's length of stay. Differences in length of stay, and in per-episode costs, were compared between residential and day hospital subjects. Lengths of stay at residential treatment were significantly longer than at day hospital, in the sample overall and in disaggregated analyses. This difference was especially marked among non-Whites. The average cost per week was USD 575 per week at day hospital, versus USD 370 per week at the residential programs. However, because of the longer stays in residential, per-episode costs were significantly higher in the sample overall and among non-Whites (and marginally higher for men). These cost results must be considered in light of the null findings comparing outcomes between subjects randomized to residential versus day hospital programs. The longer stays in the sample overall and for non-White clients at residential programs came at higher costs but did not lead to better rates of abstinence. The short stays in day hospital among non-Whites call into question the attractiveness of day hospital for minority clients. Outcomes and costs

  6. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  7. Gap Width Study and Fixture Design in Laser Butt-Welding

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    .5-2.0 m/min, the laser power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely......This paper discusses some practical consideration for design of a mechanical fixture, which enables to accurately measure the width of a gap between two stainless steel workpieces and to steadfastly clamp the workpieces for butt-welding with a high power CO2 laser.With such a fixture, a series...... of butt-welding experiment is successfully carried out in order to find the maximum allowable gap width in laser butt-welding. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0...

  8. Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Tevis D. B., E-mail: tjacobs@pitt.edu [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 3700 O’Hara St., Pittsburgh, Pennsylvania 15208 (United States); Wabiszewski, Graham E.; Goodman, Alexander J.; Carpick, Robert W., E-mail: carpick@seas.upenn.edu [Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 220 S. 33rd St., Philadelphia, Pennsylvania 19104 (United States)

    2016-01-15

    The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

  9. Visual Sensor for Sterilization of Polymer Fixtures Using Embedded Mesoporous Silicon Photonic Crystals.

    Science.gov (United States)

    Kumeria, Tushar; Wang, Joanna; Chan, Nicole; Harris, Todd J; Sailor, Michael J

    2018-01-26

    A porous photonic crystal is integrated with a plastic medical fixture (IV connector hub) to provide a visual colorimetric sensor to indicate the presence or absence of alcohol used to sterilize the fixture. The photonic crystal is prepared in porous silicon (pSi) by electrochemical anodization of single crystal silicon, and the porosity and the stop band of the material is engineered such that the integrated device visibly changes color (green to red or blue to green) when infiltrated with alcohol. Two types of self-reporting devices are prepared and their performance compared: the first type involves heat-assisted fusion of a freestanding pSi photonic crystal to the connector end of a preformed polycarbonate hub, forming a composite where the unfilled portion of the pSi film acts as the sensor; the second involves generation of an all-polymer replica of the pSi photonic crystal by complete thermal infiltration of the pSi film and subsequent chemical dissolution of the pSi portion. Both types of sensors visibly change color when wetted with alcohol, and the color reverts to the original upon evaporation of the liquid. The sensor performance is verified using E. coli-infected samples.

  10. Treatment of oligodontia with endo-osseous fixtures: experience in eight consecutive patients at the end of dental growth.

    Science.gov (United States)

    Becelli, Roberto; Morello, Roberto; Renzi, Giancarlo; Dominici, Chiara

    2007-11-01

    Clinical manifestations of oligodontia consist in agenesia of multiple teeth eventually with deciduous retained teeth, atrophy of alveolar ridge, aberrations of teeth dimension, and shape, with consequent aesthetic and functional defects. The first choice treatment is based on a team collaboration of maxillo-facial surgeon, orthodontist, and prosthodontist, and is conditioned by various clinical parameters as number and site of lacking teeth, age and dental development of patients, eventual alveolar ridge atrophy. Treatment planning should be individualized for each patient. In our experience, based on 8 consecutive patients at the end of dental growth affected by oligodontia, endo-osseous fixtures positioning was carried out in consideration of long-lasting stability and optimal aesthetical characteristics. In 5 patients rehabilitative preprosthetic surgical procedures were performed, consisting in 2 sinus lift with immediate positioning of 3 fixtures in both cases, 4 heterologous bone graft in postextractive sites with retained ankylotic deciduous teeth and 1 positioning of reabsorbable biomembrane. A temporary removable denture was positioned immediately after surgery in order to obtain a prompt aesthetical and psychosocial restore. Osseointegration ratio as observed at 8.5 years follow-up was analyzed according to surgical variables and differences in prosthetic rehabilitation (fixtures supporting single crown versus multiple crowns). Successful osteointegration was observed at 8.5 years mean follow-up in 58 fixtures, corresponding to a 96.6% ratio. Failure of integration was encountered in fixtures immediately positioned in postextractive sites having a mild grade of bone atrophy, supporting single crown. A rate of success of 100% was observed in cases of immediate or delayed positioning in postextractive or traditional sites.Fixtures positioning in patients affected by isolated oligodontia, without malformative syndromes, and at the end of dental development

  11. Post-Retrofit Residential Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

    2012-04-30

    This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be

  12. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  13. The structure of residential energy demand in Greece

    International Nuclear Information System (INIS)

    Rapanos, Vassilis T.; Polemis, Michael L.

    2006-01-01

    This paper attempts to shed light on the determinants of residential energy demand in Greece, and to compare it with some other OECD countries. From the estimates of the short-run and long-run elasticities of energy demand for the period 1965-1999, we find that residential energy demand appears to be price inelastic. Also, we do not find evidence of a structural change probably because of the low efficiency of the energy sector. We find, however, that the magnitude of the income elasticity varies substantially between Greece and other OECD countries

  14. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    This study combines principles of energy systems engineering and statistics to develop integrated models of residential energy use in the United States, to include residential recharging of electric vehicles. These models can be used by government, policymakers, and the utility industry to provide answers and guidance regarding the future of the U.S. energy system. Currently, electric power generation must match the total demand at each instant, following seasonal patterns and instantaneous fluctuations. Thus, one of the biggest drivers of costs and capacity requirement is the electricity demand that occurs during peak periods. These peak periods require utility companies to maintain operational capacity that often is underutilized, outdated, expensive, and inefficient. In light of this, flattening the demand curve has long been recognized as an effective way of cutting the cost of producing electricity and increasing overall efficiency. The problem is exacerbated by expected widespread adoption of non-dispatchable renewable power generation. The intermittent nature of renewable resources and their non-dispatchability substantially limit the ability of electric power generation of adapting to the fluctuating demand. Smart grid technologies and demand response programs are proposed as a technical solution to make the electric power demand more flexible and able to adapt to power generation. Residential demand response programs offer different incentives and benefits to consumers in response to their flexibility in the timing of their electricity consumption. Understanding interactions between new and existing energy technologies, and policy impacts therein, is key to driving sustainable energy use and economic growth. Comprehensive and accurate models of the next-generation power system allow for understanding the effects of new energy technologies on the power system infrastructure, and can be used to guide policy, technology, and economic decisions. This

  15. ENERGY STAR Certified Residential Dishwashers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 6.0 ENERGY STAR Program Requirements for Residential Dishwashers that are effective as of...

  16. ENERGY STAR Certified Residential Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are...

  17. ENERGY STAR Certified Residential Refrigerators

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are...

  18. Measurement of Mechanical Properties of PVC Foam Using a Modified Arcan Fixture

    DEFF Research Database (Denmark)

    Taher, Siavash Talebi; Thomsen, Ole Thybo; M. Dulieu-Barton, Janice

    , compressive and shear properties. The MAF enables the realization of unidirectional tensile, compressive and shear loading states, as well as high compression or tension to shear ratio bidirectional loading conditions. The MAF is attached to a standard universal test machine using specially designed grips......Previously, the Arcan test rig has been used to measure bidirectional properties of polymer foams used for sandwich core materials, especially in the tensile-shear stress region [1]. In this work, a modified Arcan fixture (MAF) is used to load polymer foam specimens to obtain their tensile...... that do not constrain the specimen either in-plane or out-of-plane and hence eliminate any paristic effects due to test machine misalignment. The focus of this paper is to compare and validate the accuracy of the material properties measured using the proposed MAF, by comparing with results obtained using...

  19. Perancangan Fixture Pada Proses Sekrap Dan Freis Untuk Memproduksi Komponen Poros Idler

    Directory of Open Access Journals (Sweden)

    Muhammad Ikhsan

    2010-10-01

    Full Text Available Idler shaft is the engine components that are often produced in the automotive field, the shaft serves to continue the effort together with the rotation. Making idler shaft through several machining processes such as lathes, sekrap, and Freis. At this time laporn designed tools to process and Freis sekrap in the production of idler shaft. The design of this tool using the clamping screw. Placed on the front clamping tools for process sekrap. Based on the results obtained, the time spent with the tools and shorter setup times smaller than that obtained without the tools, so the production cost by using the tools is greater than the production costs without the tools in this case the production shaft idler. Keywords : Fixture, clamping, idler shaft

  20. Application of the active flexible fixture with passive RCC function to peg-in-hole task

    International Nuclear Information System (INIS)

    Yamaguchi, Tomomi; Higuchi, Masahiro

    2005-01-01

    This paper describes the application of the active flexible fixture (AFLEF) with passive RCC to the peg-in-hole task on the disk in the X-band accelerator. The AFLEF can fix any work and position the fixed work at short range. In this paper, the 2-dimensional AFLEF is proposed as the simplified type and is provided with passive RCC function to be equipped with dexterity for a peg-in-hole task. As results of the experiment on the peg-in-hole task on the X-band accelerator disks with the AFLEF, we make the ability of the AFLEF for the task clear and also the boundary conditions to the complete task clear. (author)

  1. Energy literacy, awareness, and conservation behavior of residential households

    International Nuclear Information System (INIS)

    Brounen, Dirk; Kok, Nils; Quigley, John M.

    2013-01-01

    The residential sector accounts for one-fifth of global energy consumption, resulting from the requirements to heat, cool, and light residential dwellings. It is therefore not surprising that energy efficiency in the residential market has gained importance in recent years. In this paper, we examine awareness, literacy and behavior of households with respect to their residential energy expenditures. Using a detailed survey of 1721 Dutch households, we measure the extent to which consumers are aware of their energy consumption and whether they have taken measures to reduce their energy costs. Our results show that “energy literacy” and awareness among respondents is low: just 56% of the respondents are aware of their monthly charges for energy consumption, and 40% do not appropriately evaluate investment decisions in energy efficient equipment. We document that demographics and consumer attitudes towards energy conservation, but not energy literacy and awareness, have direct effects on behavior regarding heating and cooling of the home. The impact of a moderating factor, measured by thermostat settings, ultimately results in strong variation in the energy consumption of private consumers. - Highlights: • We use a detailed survey of 1,721 Dutch households to measure awareness and conservation behavior in energy consumption. • Energy literacy and awareness among residential households is low. • 40 percent of the sample does not appropriately evaluate investment decisions in energy efficient equipment • Demographics and consumer attitudes affect behavior regarding heating and cooling of a home

  2. Lighting [A guide to ecological design

    CSIR Research Space (South Africa)

    Osburn, L

    2009-02-01

    Full Text Available Lighting consumes between about 29-35% of the energy used within commercial office space while lighting only consumes about 11% of the energy used in a residential environment. Through conscientious design of the lighting systems, the lighting load...

  3. Fertility expectations and residential mobility in Britain

    Directory of Open Access Journals (Sweden)

    John Ermisch

    2016-12-01

    Full Text Available Background: It is plausible that people take into account anticipated changes in family size in choosing where to live. But estimation of the impact of anticipated events on current transitions in an event history framework is challenging because expectations must be measured in some way and, like indicators of past childbearing, expected future childbearing may be endogenous with respect to housing decisions. Objective: The objective of the study is to estimate how expected changes in family size affect residential movement in Great Britain in a way which addresses these challenges. Methods: We use longitudinal data from a mature 18-wave panel survey, the British Household Panel Survey, which incorporates a direct measure of fertility expectations. The statistical methods allow for the potential endogeneity of expectations in our estimation and testing framework. Results: We produce evidence consistent with the idea that past childbearing mainly affects residential mobility through expectations of future childbearing, not directly through the number of children in the household. But there is heterogeneity in response. In particular, fertility expectations have a much greater effect on mobility among women who face lower costs of mobility, such as private tenants. Conclusions: Our estimates indicate that expecting to have a(nother child in the future increases the probability of moving by about 0.036 on average, relative to an average mobility rate of 0.14 per annum in our sample. Contribution: Our contribution is to incorporate anticipation of future events into an empirical model of residential mobility. We also shed light on how childbearing affects mobility.

  4. Effect of LED lighting on the cooling and heating loads in office buildings

    International Nuclear Information System (INIS)

    Ahn, Byung-Lip; Jang, Cheol-Yong; Leigh, Seung-Bok; Yoo, Seunghwan; Jeong, Hakgeun

    2014-01-01

    Highlights: • Application of heat control strategy reduces total energy consumption of LED lighting. • Convective heat from LED lighting should be emitted outdoors during cooling period. • Seasonal optimization of convective heat lowers total energy consumption. - Abstract: LED lighting has the potential to provide energy savings, and in many countries, there are policies to encourage its use owing to its higher efficiency and longer life in comparison to other lighting fixtures. However, since 75–85% of the light electric power in LED lights is still generated as heat, the sole use of LED lighting in a building could have a negative effect on the cooling load. In this paper, we study the heating properties of LED lighting and establish a management strategy to exploit these properties to reduce the energy used for heating and cooling of buildings. Using a simulation program, the energy consumption of the Green Building in Daejeon, Korea, and the virtual building provided by the U.S. Department of Energy (DOE) was computed according for different light fixtures. A control strategy is more applicable to LED lighting than to general fluorescent lighting, especially for the cooling of a building, because the use of a return-air duct and the heat sinks on the LED fixtures allow the heat to be better directed. Deployment of LED lights in combination with such a control strategy can help to increase the energy efficiency of a building

  5. Experimental assessment of the thermal performance of storage canister/holding fixture configurations for the Los Alamos Nuclear Materials Storage Facility

    International Nuclear Information System (INIS)

    Bernardin, J.D.; Naffziger, D.C.; Gregory, W.S.

    1997-11-01

    This report presents experimental results on the thermal performance of various nested canister configurations and canister holding fixtures to be used in the Los Alamos Nuclear Materials Storage Facility. The experiment consisted of placing a heated aluminum billet (to represent heat-generating nuclear material) inside curved- and flat-bottom canisters with and without holding plate fixtures and/or extended fin surfaces. Surface temperatures were measured at several locations on the aluminum billet, inner and outer canisters, and the holding plate fixture to assess the effectiveness of the various configurations in removing and distributing the heat from the aluminum billet. Results indicated that the curved-bottom canisters, with or without holding fixtures, were extremely ineffective in extracting heat from the aluminum billet. The larger thermal contact area provided by the flat-bottom canisters compared with the curved-bottom design, greatly enhanced the heat removal process and lowered the temperature of the aluminum billet considerably. The addition of the fixture plates to the flat-bottom canister geometry greatly enhances the heat removal rates and lowers the canister operating temperatures considerably. The addition of the fixture plates to the flat-bottom canister geometry greatly enhances the heat removal rates and lowers the canister operating temperatures considerably. Finally, the addition of extended fin surfaces to the outer flat-bottom canister positioned on a fixture plate, reduced the canister temperatures still further

  6. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models.

    Science.gov (United States)

    Yamaguchi, Satoshi; Yamanishi, Yasufumi; Machado, Lucas S; Matsumoto, Shuji; Tovar, Nick; Coelho, Paulo G; Thompson, Van P; Imazato, Satoshi

    2018-01-01

    The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (pimplant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. Data on European non-residential buildings.

    Science.gov (United States)

    D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo

    2017-10-01

    This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.

  8. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  9. Simulating the effects of plasma disruption with a 1 MA current pulse in a coaxial test fixture

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1985-01-01

    A test fixture for simulating plasma disruptions, comprising two coaxial cylinders, has been designed for use with Argonne's electromagnetic test facility FELIX. A pulsed power supply drives a half cycle sine wave current of 10 0 A through the test fixture generating fields of -1 . The coaxial structure is 140 cm long, has an outer cylinder with an OD of 78 cm and an inner cylinder with an OD of 8.3 cm. It is surrounded by the FELIX solenoid field of 1 T. This proposed upgrade of the FELIX facility should be useful for testing the effect of plasma disruption on First Wall-Blanket-Shield (FWBS) structures; a future upgrade of the solenoid field to 4 T will allow to simulate reactor conditions even better

  10. Simulating the effects of plasma disruption with A 1 MA current pulse in a coaxial test fixture

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1985-01-01

    A test fixture for simulating plasma disruptions, comprising two coaxial cylinders, has been designed for use with Argonne's electromagnetic test facility FELIX. A pulsed power supply drives a half cycle sine wave current of 10 0 A through the test fixture generating fields of -1 . The coaxial structure is 140 cm long, has an outer cylinder with an OD of 78 cm and an inner cylinder with an OD of 8.3 cm. It is surrounded by the FELIX solenoid field of 1 T. This proposed upgrade of the FELIX facility should be useful for testing the effect of plasma disruption on First Wall-Blanket-Shield (FWBS) structures; a future upgrade of the solenoid field to 4 T will allow to simulate reactor conditions even better

  11. Understanding Residential Polarization in a Globalizing City

    Directory of Open Access Journals (Sweden)

    Ibrahim Rotimi Aliu

    2013-12-01

    Full Text Available This study examines the spatial polarization that characterizes the dwellings in the African leading megacity of Lagos. Data were collected through an extensive housing survey carried out on 1,485 household residences in 56 wards within 12 administrative units in Lagos megacity. The spatial dimension of residential density in the city generates three unique residential patterns which are low residential density (LRD, medium residential density (MRD, and high residential density (HRD areas. Descriptive and multivariate inferential statistics were used to render explanations for the spatial variations in the residential quality variables in the study area. Findings indicated that a clear difference exists in the residential quality within the three residential density areas of Lagos. High correlations exist among the residential quality indicators and housing type. The principal component analysis shows that residential polarizations that occur in the LRD, MRD, and HRD are based on the location, dwelling facility, interior and exterior quality, neighborhood integrity, social bond, barrier to entry, and security. The practical implications of residential polarizations along the residential density areas are explicitly expressed.

  12. Feasibility of evaluating the integrity of FTR duct to end fixture welds using acoustic emission monitoring

    International Nuclear Information System (INIS)

    Trantow, R.L.

    1975-11-01

    A method of applying real-time acoustic emission (AE) source location to evaluate the integrity of duct-to-end fixture welds was developed and evaluated using the HEDL R8-4 AE monitor coupled with a PDP-8e minicomputer. Operational software was developed to control the system's data acquisition, storage, and display functions. Performance was evaluated on the basis of comparisons between AE source location data and subsequent destructive examination of six duct-to-transition ring qualification welds. Ten separate discontinuities seen in the metallography performed at 35 locations along these welds correlated with the averaged acoustic emission activity revealed by the AE source location maps. This relationship is not presently considered to be usable as a system calibration method however, because of the limited range of discontinuity lengths (from 0.0003 to 0.004 in. long) that were correlated. The presence of six other discontinuities, found in regions showing low levels of emission activity, indicated that significant stress risers can go undetected under the conditions investigated

  13. Seismic responses of an unanchored generic fixture with different simulated boundary conditions

    International Nuclear Information System (INIS)

    Wu, T.S.; Blomquist, C.A.; Herceg, J.E.

    1994-01-01

    In the design of equipment for seismic loadings, it is common to anchor the equipment to prevent tipping or sliding. However, there are situations where the equipment should not be anchored. An unanchored piece of equipment is held to the floor only by the gravitational effect and, in the absence of friction, it could move freely. In the analytical investigation of an unanchored item during a seismic event, there is uncertainty on the proper simulation of the boundary conditions so that the analysis model will have no rigid-body motion. Seismic responses of a simple analytical model that is representative of a group of unanchored equipment have been investigated with different sets of simulated boundary conditions. The results show that, when the main interest of investigation is to assess the potential for tipping during an earthquake, the case with one of the four supporting pads simply supported, its two neighboring pads constrained against twisting motion, and all pads without vertical displacements yields the most conservative prediction. The analysis is applied to the fuel processing cell of the Integral Fast Reactor project. In order not to breach the liner of the existing facility and to keep operational flexibility of the fixtures, all new equipment to be installed within the fuel processing cell are required to be unanchored

  14. Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication

    Science.gov (United States)

    Rubin, Binyamin; George, Jason; Singhal, Riju

    2018-04-01

    Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.

  15. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures.

    Science.gov (United States)

    Wadowsky, R M; Yee, R B; Mezmar, L; Wing, E J; Dowling, J N

    1982-05-01

    Samples obtained from plumbing systems of hospitals, nonhospital institutions and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pneumophila serogroups 1, 5, and 6 were recovered from plumbing fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54 degrees C, but not in those maintained at 71 and 77 degrees C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.

  16. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Wadowsky, R.M.; Yee, R.B.; Mezmar, L.; Wing, E.J.; Dowling, J.N.

    1982-05-01

    Samples obtained from plumbing systems of hospitals, nonhospital institutions, and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pnenumophila serogroups 1.5, and 6 were recovered from plubming fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54/sup 0/C, but not in those maintained at 71 and 77/sup 0/C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.

  17. Developing Parametric Models for the Assembly of Machine Fixtures for Virtual Multiaxial CNC Machining Centers

    Science.gov (United States)

    Balaykin, A. V.; Bezsonov, K. A.; Nekhoroshev, M. V.; Shulepov, A. P.

    2018-01-01

    This paper dwells upon a variance parameterization method. Variance or dimensional parameterization is based on sketching, with various parametric links superimposed on the sketch objects and user-imposed constraints in the form of an equation system that determines the parametric dependencies. This method is fully integrated in a top-down design methodology to enable the creation of multi-variant and flexible fixture assembly models, as all the modeling operations are hierarchically linked in the built tree. In this research the authors consider a parameterization method of machine tooling used for manufacturing parts using multiaxial CNC machining centers in the real manufacturing process. The developed method allows to significantly reduce tooling design time when making changes of a part’s geometric parameters. The method can also reduce time for designing and engineering preproduction, in particular, for development of control programs for CNC equipment and control and measuring machines, automate the release of design and engineering documentation. Variance parameterization helps to optimize construction of parts as well as machine tooling using integrated CAE systems. In the framework of this study, the authors demonstrate a comprehensive approach to parametric modeling of machine tooling in the CAD package used in the real manufacturing process of aircraft engines.

  18. A developed wedge fixtures assisted high precision TEM samples pre-thinning method: Towards the batch lamella preparation

    Directory of Open Access Journals (Sweden)

    Dandan Wang

    2017-04-01

    Full Text Available Ion milling, wedge cutting or polishing, and focused ion beam (FIB milling are widely-used techniques for the transmission electron microscope (TEM sample preparation. Especially, the FIB milling provides a site-specific analysis, deposition, and ablation of materials in the micrometer and nanometer scale. However, the cost of FIB tools has been always a significant concern. Since it is inevitable to use the FIB technique, the improvement of efficiency is a key point. Traditional TEM sample preparation with FIB was routinely implemented on a single sample each time. Aiming at cost efficiency, a new pre-thinning technique for batch sample preparation was developed in this paper. The present proposal combines the sample preparation techniques with multi-samples thinning, cross-section scanning electron microscopy (SEM, wedge cutting, FIB and other sample pre-thinning techniques. The new pre-thinning technique is to prepare an edge TEM sample on a grinding and polishing fixture with a slant surface. The thickness of the wedges sample can be measured to 1∼2 μm under optical microscope. Therefore, this fixture is superior to the traditional optical method of estimating the membrane thickness. Moreover, by utilizing a multi-sample holding fixture, more samples can be pre-thinned simultaneously, which significantly improved the productivity of TEM sample preparation.

  19. Technical Problems of Residential Construction

    Science.gov (United States)

    Nowogońska, Beata; Cibis, Jerzy

    2017-10-01

    Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.

  20. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  1. Residential solar-heating system

    Science.gov (United States)

    1978-01-01

    Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

  2. Convergence of Residential Gateway Technology

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Balm, M.; Jong, C.M. de; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  3. Convergence of residential gateway technology

    NARCIS (Netherlands)

    Hartog, den F.T.H.; Balm, M.; Jong, de C.M.; Kwaaitaal, J.J.B.

    2004-01-01

    A new OSI-based model is described that can be used for the classification of residential gateways. It is applied to analyze current gateway solutions and draw evolutionary paths for the medium to long term. From this it is concluded that particularly set-top boxes and broadband modems, as opposed

  4. Trends of Sustainable Residential Architecture

    OpenAIRE

    Narvydas, A

    2014-01-01

    The article is based on Master’s research conducted during Scottish Housing Expo 2010. The aim of the research was to determine the prevailing trends in sustainable residential architecture. Each trend can be described by features detected during visual and technical observation of project data. Based on that architects may predict possible problems related to a specific trend.

  5. Reduce tax on residential mobility

    NARCIS (Netherlands)

    van Ewijk, C.; van Leuvensteijn, M.

    2010-01-01

    How can Europe increase structural growth? This column argues that labour market flexibility is key. As a major barrier to labour movement is rigidity in the housing market, abolishing transfer taxes on residential property could result in gains of up to 0.4% of GDP.

  6. Zones 30 : urban residential areas.

    NARCIS (Netherlands)

    2006-01-01

    Sustainable Safety uses a road categorization in which through traffic is concentrated on motorways and other main roads. In residential areas, which have a living, shopping, or work function, through traffic is discouraged by setting a speed limit of 30 km/h, and by speed reducing measures such as

  7. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    Science.gov (United States)

    Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380

  8. 10 CFR 434.514 - Lighting.

    Science.gov (United States)

    2010-01-01

    ... ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power... lighting power used to calculate the Design Energy Consumption shall be the actual adjusted power for...

  9. External built residential environment characteristics that affect mental health of adults.

    Science.gov (United States)

    Ochodo, Charles; Ndetei, D M; Moturi, W N; Otieno, J O

    2014-10-01

    External built residential environment characteristics include aspects of building design such as types of walls, doors and windows, green spaces, density of houses per unit area, and waste disposal facilities. Neighborhoods that are characterized by poor quality external built environment can contribute to psychosocial stress and increase the likelihood of mental health disorders. This study investigated the relationship between characteristics of external built residential environment and mental health disorders in selected residences of Nakuru Municipality, Kenya. External built residential environment characteristics were investigated for 544 residents living in different residential areas that were categorized by their socioeconomic status. Medically validated interview schedules were used to determine mental health of residents in the respective neighborhoods. The relationship between characteristics of the external built residential environment and mental health of residents was determined by multivariable logistic regression analyses and chi-square tests. The results show that walling materials used on buildings, density of dwelling units, state of street lighting, types of doors, states of roofs, and states of windows are some built external residential environment characteristics that affect mental health of adult males and females. Urban residential areas that are characterized by poor quality external built environment substantially expose the population to daily stressors and inconveniences that increase the likelihood of developing mental health disorders.

  10. Fixture and method for rectifying damaged guide thimble insert sleeves in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    A guide thimble damage-rectifying method is described for use on a reconstitutable fuel assembly being held in a work station with its top nozzle removed to expose a plurality of guide thimbles having one of several different types of damage. The method consists of: (a) providing a base having a plurality of tool positioning openings defined therein in a pattern matched with that of the guide thimbles of the fuel assembly; (b) mounting the base on the work station with its tool positioning openings in alignment with the guide thimbles of the fuel assembly and such that the base is movable toward the guide thimbles; (c) providing a plurality of different tools each operable to rectify one of the different types of guide thimble damage; (d) mounting selected ones of the different tools in respective ones of the openings of the base in alignment with ones of the thimbles having the respective types of guide thimble damage capable of being rectified by the selected tools such that upon movement of the base toward the guide thimbles the respective types of guide thimble damage will be rectified by the selected tools; (e) providing a group of positioning elements; (f) mounting the positioning elements in selected ones of the base openings corresponding to undamaged ones of the guide thimbles such that upon movement of the base toward the guide thimbles the positioning elements become mounted on upper end portions of the corresponding undamaged ones of the guide thimbles for precisely locating the fixture relative to the guide thimble upper end portions for accurate performance of the repairable damage rectifying operation by the tools as the base is moved toward the guide thimbles; and (g) moving the base toward the guide thimbles so as to mount the positioning elements on the corresponding ones of the undamaged guide thimbles and effect rectification of the damaged guide thimbles by the selected tools

  11. Residential mobility and childhood leukemia.

    Science.gov (United States)

    Amoon, A T; Oksuzyan, S; Crespi, C M; Arah, O A; Cockburn, M; Vergara, X; Kheifets, L

    2018-07-01

    Studies of environmental exposures and childhood leukemia studies do not usually account for residential mobility. Yet, in addition to being a potential risk factor, mobility can induce selection bias, confounding, or measurement error in such studies. Using data collected for California Powerline Study (CAPS), we attempt to disentangle the effect of mobility. We analyzed data from a population-based case-control study of childhood leukemia using cases who were born in California and diagnosed between 1988 and 2008 and birth certificate controls. We used stratified logistic regression, case-only analysis, and propensity-score adjustments to assess predictors of residential mobility between birth and diagnosis, and account for potential confounding due to residential mobility. Children who moved tended to be older, lived in housing other than single-family homes, had younger mothers and fewer siblings, and were of lower socioeconomic status. Odds ratios for leukemia among non-movers living mobility, including dwelling type, increased odds ratios for leukemia to 2.61 (95% CI: 1.76-3.86) for living mobility of childhood leukemia cases varied by several sociodemographic characteristics, but not by the distance to the nearest power line or calculated magnetic fields. Mobility appears to be an unlikely explanation for the associations observed between power lines exposure and childhood leukemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. RESIDENTIAL MORTGAGE IN MODERN RUSSIA

    Directory of Open Access Journals (Sweden)

    Dementiev N. P.

    2015-03-01

    Full Text Available The article presents a comparative analysis of residential mortgages in Russia and the United States. The primary ways of mortgage refinancing are outlined. Predominance of the elements of two-level refinancing system of residential mortgage in Russia and the United States is shown. The activity of the Agency for Housing Mortgage Lending (AHML, the basic tool of the Russian government’s mortgage policy, is described in detail. In its objectives and functions the AHML is similar to the American mortgage agencies Ginnie Mae, Fannie Mae and Freddie Mac. Similarities were identified in the Russian and US residential mortgages in the pre-crisis period (high rates of mortgage growth, favourable economic conjuncture, low interest rates, large increase in house prices, speculative housing demand. During the mortgage crisis, the policies of the Russian and US governments and monetary authorities had also much in common (monetary policy easing, cheap central banks loans, extended facilities of mortgage refinancing on the part of state agencies, mortgage rescue scheme, social mortgage programs. But the scope of mortgage in Russia is enormously narrow as compared to the US mortgage. The most important reason for that - low incomes of the Russian population.

  13. Regionalised tertiary psychiatric residential facilities.

    Science.gov (United States)

    Lesage, Alain; Groden, David; Goldner, Elliot M; Gelinas, Daniel; Arnold, Leslie M

    2008-01-01

    Psychiatric hospitals remain the main venue for long-term mental health care and, despite widespread closures and downsizing, no country that built asylums in the last century has done away with them entirely--with the recent exception of Italy. Differentiated community-based residential alternatives have been developed over the past decades, with staffing levels that range from full-time professional, to daytime only, to part-time/on-call. This paper reviews the characteristics of community-based psychiatric residential care facilities as an alternative to long-term care in psychiatric hospitals. It describes five factors decision makers should consider: 1. number of residential places needed; 2. staffing levels; 3. physical setting; 4. programming; and 5. governance and financing. In Italy, facilities with full-time professional staff have been developed since the mid-1990s to accommodate the last cohorts of patients discharged from psychiatric hospitals. In the United Kingdom, experiments with hostel wards since the 1980s have shown that home-like, small-scale facilities with intensive treatment and rehabilitation programming can be effective for the most difficult-to-place patients. More recently in Australia, Community Care Units (CCUs) have been applying this concept. In the Canadian province of British Columbia (BC), Tertiary Psychiatric Residential Facilities (TPRFs) have been developed as part of an effort to regionalise health and social services and downsize and ultimately close its only psychiatric hospital. This type of service must be further developed in addition to the need for forensic, acute-care and intermediate-level beds, as well as for community-based care such as assertive community treatment and intensive case management. All these types of services, together with long-term community-based residential care, constitute the elements of a balanced mental health care system. As part of a region's balanced mental health care plan, these Tertiary

  14. LEDWIRE: A Versatile Networking Platform for Smart LED Lighting Applications Using LIN-Bus and WSNs

    Directory of Open Access Journals (Sweden)

    Dimitrios D. Piromalis

    2016-05-01

    Full Text Available In this paper, the architecture of a versatile networking and control platform for Light-Emitting Diode (LED lighting applications is presented, based on embedded wireless and wired networking technologies. All the possible power and control signals distribution topologies of the lighting fixtures are examined with particular focus on dynamic lighting applications with design metrics as the cost, the required wiring installation expenses and maintenance complexity. The proposed platform is optimized for applications where the grouping of LED-based lighting fictures clusters is essential, as well as their synchronization. With such an approach, the distributed control and synchronization of LED lighting fixtures' clusters is performed through a versatile network that uses the single wire Local Interconnect Network (LIN bus. The proposed networking platform is presented in terms of its physical layer architecture, its data protocol configuration, and its functionality for smart control. As a proof of concept, the design of a LED lighting fixture together with a LIN-to-IEEE802.15.4/ZigBee data gateway is presented.

  15. Post-Game High Protein Intake May Improve Recovery of Football-Specific Performance during a Congested Game Fixture

    DEFF Research Database (Denmark)

    Poulios, Athanasios; Fatouros, Ioannis G; Mohr, Magni

    2018-01-01

    The effects of protein supplementation on performance recovery and inflammatory responses during a simulated one-week in-season microcycle with two games (G1, G2) performed three days apart were examined. Twenty football players participated in two trials, receiving either milk protein concentrat...... short-lived reduction after G2 in PRO compared to PLA. In summary, these results provide evidence that protein feeding may more efficiently restore football-specific performance and strength and provide antioxidant protection during a congested game fixture....

  16. Residential care : Dutch and Italian residents of residential care facilities compared

    NARCIS (Netherlands)

    de Heer-Wunderink, Charlotte; Caro-Nienhuis, Annemarie D.; Sytema, Sjoerd; Wiersma, Durk

    2008-01-01

    Aims - Characteristics of patients living in residential care facilities and the availability of mental hospital- and residential beds in Italy and The Netherlands were compared to assess whether differences in the process of deinstitutionalisation have influenced the composition of their

  17. The relation between residential property and its surroundings and day- and night-time residential burglary

    NARCIS (Netherlands)

    Montoya, Lorena; Junger, Marianne; Ongena, Yfke

    This article examines how residential property and its surroundings influence day- and night-time residential burglary. Crime Prevention Through Environmental Design (CPTED) principles of territoriality, surveillance, access control, target hardening, image maintenance, and activity support underpin

  18. The Relation Between Residential Property and its Surroundings and Day- and Night-Time Residential Burglary

    NARCIS (Netherlands)

    Montoya, L.; Junger, Marianne; Ongena, Yfke

    This article examines how residential property and its surroundings influence day- and night-time residential burglary. Crime Prevention Through Environmental Design (CPTED) principles of territoriality, surveillance, access control, target hardening, image maintenance, and activity support underpin

  19. Conceptual design of modular fixture for frame welding and drilling process integration case study: Student chair in UNS industrial engineering integrated practicum

    Science.gov (United States)

    Darmawan, Tofiq Dwiki; Priadythama, Ilham; Herdiman, Lobes

    2018-02-01

    Welding and drilling are main processes of making chair frame from metal material. Commonly, chair frame construction includes many arcs which bring difficulties for its welding and drilling process. In UNS industrial engineering integrated practicum there are welding fixtures which use to fixing frame component position for welding purpose. In order to achieve exact holes position for assembling purpose, manual drilling processes were conducted after the frame was joined. Unfortunately, after it was welded the frame material become hard and increase drilling tools wear rate as well as reduce holes position accuracy. The previous welding fixture was not equipped with clamping system and cannot accommodate drilling process. To solve this problem, our idea is to reorder the drilling process so that it can be execute before welding. Thus, this research aims to propose conceptual design of modular fixture which can integrate welding and drilling process. We used Generic Product Development Process to address the design concept. We collected design requirements from 3 source, jig and fixture theoretical concepts, user requirements, and clamping part standards. From 2 alternatives fixture tables, we propose the first which equipped with mounting slots instead of holes. We test the concept by building a full sized prototype and test its works by conducting welding and drilling of a student chair frame. Result from the welding and drilling trials showed that the holes are on precise position after welding. Based on this result, we conclude that the concept can be a consideration for application in UNS Industrial Engineering Integrated Practicum.

  20. Dynamic virtual fixture on the Euclidean group for admittance-type manipulator in deforming environments.

    Science.gov (United States)

    Zhang, Dongwen; Zhu, Qingsong; Xiong, Jing; Wang, Lei

    2014-04-27

    In a deforming anatomic environment, the motion of an instrument suffers from complex geometrical and dynamic constraints, robot assisted minimally invasive surgery therefore requires more sophisticated skills for surgeons. This paper proposes a novel dynamic virtual fixture (DVF) to enhance the surgical operation accuracy of admittance-type medical robotics in the deforming environment. A framework for DVF on the Euclidean Group SE(3) is presented, which unites rotation and translation in a compact form. First, we constructed the holonomic/non-holonomic constraints, and then searched for the corresponded reference to make a distinction between preferred and non-preferred directions. Second, different control strategies are employed to deal with the tasks along the distinguished directions. The desired spatial compliance matrix is synthesized from an allowable motion screw set to filter out the task unrelated components from manual input, the operator has complete control over the preferred directions; while the relative motion between the surgical instrument and the anatomy structures is actively tracked and cancelled, the deviation relative to the reference is compensated jointly by the operator and DVF controllers. The operator, haptic device, admittance-type proxy and virtual deforming environment are involved in a hardware-in-the-loop experiment, human-robot cooperation with the assistance of DVF controller is carried out on a deforming sphere to simulate beating heart surgery, performance of the proposed DVF on admittance-type proxy is evaluated, and both human factors and control parameters are analyzed. The DVF can improve the dynamic properties of human-robot cooperation in a low-frequency (0 ~ 40 rad/sec) deforming environment, and maintain synergy of orientation and translation during the operation. Statistical analysis reveals that the operator has intuitive control over the preferred directions, human and the DVF controller jointly control the

  1. Performance comparison of direct and indirect lighting systems

    International Nuclear Information System (INIS)

    Rubinstein, F.; Morse, O.; Clark, T.

    1993-01-01

    The performance of a retrofitted indirect lighting system was compared to the performance of a typical de-lamped direct lighting system in a partitioned office space. Power, illuminance and luminance measurements were made for the de-lamped direct lighting system and after installation of the indirect lighting system with various lamp and ballast combinations. Using the same lamps and ballasts, average workplace illuminance was slightly higher with indirect lighting than with direct lighting. With indirect lighting, workplace lumen efficacy was 4.5% lower due to the higher power draw of the lamps in the more open and cooler indirect fixtures. Indirect lighting with 36 watt T-8 lamps and electronic ballasts achieved an initial average workplace illuminance of 45 foot-candles in the partitioned office space at only 1.1 w/ft 2

  2. The SmartH2O project: a platform supporting residential water management through smart meters and data intensive modeling

    Science.gov (United States)

    Cominola, A.; Nanda, R.; Giuliani, M.; Piga, D.; Castelletti, A.; Rizzoli, A. E.; Maziotis, A.; Garrone, P.; Harou, J. J.

    2014-12-01

    Designing effective urban water demand management strategies at the household level does require a deep understanding of the determinants of users' consumption. Low resolution data on residential water consumption, as traditionally metered, can only be used to model consumers' behavior at an aggregate level whereas end uses breakdown and the motivations and individual attitudes of consumers are hidden. The recent advent of smart meters allows gathering high frequency consumption data that can be used both to provide instantaneous information to water utilities on the state of the network and continuously inform the users on their consumption and savings. Smart metered data also allow for the characterization of water end uses: this information, coupled with users' psychographic variables, constitutes the knowledge basis for developing individual and multi users models, through which water utilities can test the impact of different management strategies. SmartH2O is an EU funded project which aims at creating an ICT platform able to (i) capture and store quasi real time, high resolution residential water usage data measured with smart meters, (ii) infer the main determinants of residential water end uses and build customers' behavioral models and (iii) predict how the customer behavior can be influenced by various water demand management strategies, spanning from dynamic water pricing schemes to social awareness campaigns. The project exploits a social computing approach for raising users' awareness about water consumption and pursuing water savings in the residential sector. In this work, we first present the SmartH2O platform and data collection, storage and analysis components. We then introduce some preliminary models and results on total water consumption disaggregation into end uses and single user behaviors using innovative fully automated algorithms and overcoming the need of invasive metering campaigns at the fixture level.

  3. GridLAB-D Technical Support Document: Residential End-Use Module Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Zachary T.; Gowri, Krishnan; Katipamula, Srinivas

    2008-07-31

    1.0 Introduction The residential module implements the following end uses and characteristics to simulate the power demand in a single family home: • Water heater • Lights • Dishwasher • Range • Microwave • Refrigerator • Internal gains (plug loads) • House (heating/cooling loads) The house model considers the following four major heat gains/losses that contribute to the building heating/cooling load: 1. Conduction through exterior walls, roof and fenestration (based on envelope UA) 2. Air infiltration (based on specified air change rate) 3. Solar radiation (based on CLTD model and using tmy data) 4. Internal gains from lighting, people, equipment and other end use objects. The Equivalent Thermal Parameter (ETP) approach is used to model the residential loads and energy consumption. The following sections describe the modeling assumptions for each of the above end uses and the details of power demand calculations in the residential module.

  4. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  5. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  6. Residential Solar Design Review: A Manual on Community Architectural Controls and Solar Energy Use.

    Science.gov (United States)

    Jaffe, Martin; Erley, Duncan

    Presented are architectural design issues associated with solar energy use, and procedures for design review committees to consider in examining residential solar installation in light of existing aesthetic goals for their communities. Recommended design review criteria include the type of solar system being used and the ways in which the system…

  7. Therapeutic Residential Care for Children and Youth:

    DEFF Research Database (Denmark)

    Whittaker, James K.; Holmes, Lisa; del Valle, Jorge F.

    2016-01-01

    so in closer collaboration with their families and in closer proximity to their home communities; and, (3) with the hope of reducing the high costs often associated with group residential provision. In some jurisdictions, efforts to reduce residential care resources in the absence of sufficient...... alternatives to serve high-resource needing youth has had unintended and negative consequences. It is within this context that a working group international experts representing research, policy, service delivery and families (International Work Group for Therapeutic Residential Care) convened at the Centre...... for Child and Family Research, Loughborough University in the U.K. for a Summit meeting on therapeutic residential care for children and youth funded by the Sir Halley Stewart Trust (UK). The focus centered on what is known about therapeutic residential care and what key questions should inform a priority...

  8. Durability of light steel framing in residential applications

    OpenAIRE

    Lawson, RM; Popo-Ola, S.O.; Way, A.; Heatley, T; Pedreschi, Remo

    2010-01-01

    This paper presents a summary and analysis of research findings on the durability of galvanised cold-formed steel sections used in housing in order to deduce their design life. These cold-formed sections are produced from pre-galvanised strip steel. It reviews reports and publications from research projects carried out by Corus and the Steel Construction Institute on zinc-coated, cold-formed steel products. New data have also been gathered from measurements on houses and similar buildings tha...

  9. Representation of chromatic distribution for lighting system

    Science.gov (United States)

    Rossi, Maurizio; Musante, Fulvio

    2015-01-01

    For the luminaire manufacturer, the measurement of the lighting intensity distribution (LID) emitted by lighting fixture is based on photometry. So light is measured as an achromatic value of intensity and there is no the possibility to discriminate the measurement of white vs. colored light. At the Laboratorio Luce of Politecnico di Milano a new instrument for the measurement of spectral radiant intensities distribution for lighting system has been built: the goniospectra- radiometer. This new measuring tool is based on a traditional mirror gonio-photometer with a CCD spectraradiometer controlled by a PC. Beside the traditional representation of photometric distribution we have introduced a new representation where, in addition to the information about the distribution of luminous intensity in space, new details about the chromaticity characteristic of the light sources have been implemented. Some of the results of this research have been applied in developing and testing a new line of lighting system "My White Light" (the research project "Light, Environment and Humans" funded in the Italian Lombardy region Metadistretti Design Research Program involving Politecnico di Milano, Artemide, Danese, and some other SME of the Lighting Design district), giving scientific notions and applicative in order to support the assumption that colored light sources can be used for the realization of interior luminaries that, other than just have low power consumption and long life, may positively affect the mood of people.

  10. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems

  11. Residential electricity demand in Singapore

    International Nuclear Information System (INIS)

    Ang, B.W.; Goh, T.N.; Liu, X.Q.

    1992-01-01

    Residential electricity consumption in Singapore increased at a rate of 8.8% per year between 1972 and 1990. Estimates of the long-run income and price elasticities are 1.0 and -0.35, respectively. The energy-conservation campaigns that have been launched are found to have marginal effects on consumption. A statistical analysis shows that the consumption is sensitive to small changes in climatic variables, particularly the temperature, which is closely linked to the growing diffusion of electric appliances for environmental controls. There has been a temporal increase in the ownership levels of appliances associated with increasing household incomes. However, other factors were involved since the ownership levels would also increase over time after the elimination of the income effect. A large part of the future growth in electricity demand will arise from the growing need for air-conditioning, which will lead to increasingly large seasonal variations in electricity use. (author)

  12. Residential radon survey in Finland

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Castren, O.

    1993-02-01

    The study measured the indoor radon concentration in the dwellings of 3074 persons, selected randomly from the central population register of Finland. Alpha track detectors and two consecutive half year measuring periods were used. The national mean of indoor radon concentration for persons living in low-rise residential buildings as well as blocks of flats was 145 and 82 Bq/m 3 , respectively. The mean for the total population was 123 Bq/m 3 . Based on the decision of the Ministry of Social Affairs and Health in 1992, the indoor radon concentration should not exceed 400 Bq/m 3 in already existing houses, the target for new construction being less than 200 Bq/m 3 . According to the study, the percentage of the Finnish population living in houses with an indoor radon concentration exceeding 200, 400 and 800 Bq/m 3 was 12.3 %, 3.6 % and 1.0 %

  13. Contextualising Water Use in Residential Settings: A Survey of Non-Intrusive Techniques and Approaches

    Directory of Open Access Journals (Sweden)

    Davide Carboni

    2016-05-01

    Full Text Available Water monitoring in households is important to ensure the sustainability of fresh water reserves on our planet. It provides stakeholders with the statistics required to formulate optimal strategies in residential water management. However, this should not be prohibitive and appliance-level water monitoring cannot practically be achieved by deploying sensors on every faucet or water-consuming device of interest due to the higher hardware costs and complexity, not to mention the risk of accidental leakages that can derive from the extra plumbing needed. Machine learning and data mining techniques are promising techniques to analyse monitored data to obtain non-intrusive water usage disaggregation. This is because they can discern water usage from the aggregated data acquired from a single point of observation. This paper provides an overview of water usage disaggregation systems and related techniques adopted for water event classification. The state-of-the art of algorithms and testbeds used for fixture recognition are reviewed and a discussion on the prominent challenges and future research are also included.

  14. Characterizing Synergistic Water and Energy Efficiency at the Residential Scale Using a Cost Abatement Curve Approach

    Science.gov (United States)

    Stillwell, A. S.; Chini, C. M.; Schreiber, K. L.; Barker, Z. A.

    2015-12-01

    Energy and water are two increasingly correlated resources. Electricity generation at thermoelectric power plants requires cooling such that large water withdrawal and consumption rates are associated with electricity consumption. Drinking water and wastewater treatment require significant electricity inputs to clean, disinfect, and pump water. Due to this energy-water nexus, energy efficiency measures might be a cost-effective approach to reducing water use and water efficiency measures might support energy savings as well. This research characterizes the cost-effectiveness of different efficiency approaches in households by quantifying the direct and indirect water and energy savings that could be realized through efficiency measures, such as low-flow fixtures, energy and water efficient appliances, distributed generation, and solar water heating. Potential energy and water savings from these efficiency measures was analyzed in a product-lifetime adjusted economic model comparing efficiency measures to conventional counterparts. Results were displayed as cost abatement curves indicating the most economical measures to implement for a target reduction in water and/or energy consumption. These cost abatement curves are useful in supporting market innovation and investment in residential-scale efficiency.

  15. Influence Of The Gripping Fixture On The Modified Compact Tension Test Results: Evaluation Of The Experiments On Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Holušová Táňa

    2015-12-01

    Full Text Available The modified compact tension test (MCT might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced.

  16. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D [OH State University, Columbus, OH (United States)

    2015-06-15

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

  17. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    International Nuclear Information System (INIS)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D

    2015-01-01

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis

  18. 12 CFR 541.23 - Residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Residential real estate. 541.23 Section 541.23... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.23 Residential real estate. The terms residential real estate... home used in part for business); (c) Other real estate used for primarily residential purposes other...

  19. 12 CFR 541.16 - Improved residential real estate.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Improved residential real estate. 541.16... REGULATIONS AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.16 Improved residential real estate. The term improved residential real estate means residential real estate containing offsite or other improvements...

  20. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  1. Development of Residential SOFC Cogeneration System

    International Nuclear Information System (INIS)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-01-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the 'Demonstrative Research on Solid Oxide Fuel Cells' Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  2. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  3. Influence of Macroeconomic Factors on Residential Property ...

    African Journals Online (AJOL)

    Sultan

    exerted by macroeconomic factors on residential property returns in Abuja. The backward .... explanatory power and positive influence of employment and ...... Project. Management In Property Development: the Nigeria experience. Ibadan:.

  4. Plasma Processing of Model Residential Solid Waste

    Science.gov (United States)

    Messerle, V. E.; Mossé, A. L.; Nikonchuk, A. N.; Ustimenko, A. B.; Baimuldin, R. V.

    2017-09-01

    The authors have tested the technology of processing of model residential solid waste. They have developed and created a pilot plasma unit based on a plasma chamber incinerator. The waste processing technology has been tested and prepared for commercialization.

  5. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  6. Managing the environmental impacts of utility lighting retrofits programs

    International Nuclear Information System (INIS)

    Cress, K.

    1993-01-01

    One of the most popular demand-side management (DSM) programs currently being sponsored by electric utilities is the removal of old fluorescent light ballasts and replacing them with more efficient models. This type of program, however, can produce a substantial waste stream of the old ballasts, many of which contain Polychlorinated Biphenyl(s) (PCBs), a regulated hazardous substance. The proper disposal of spent light ballasts should be an integral component of DSM programs. This paper will discuss the experience that New England Electric System (NEES) 1 has had with disposing of spent light ballasts resulting from the implementation of our Small Commercial ampersand Industrial Program (a direct install lighting program which provides for the installation of energy efficient lighting measures which include fluorescent fixtures, ballasts and lamps, specular reflectors, compact fluorescent systems, high intensity discharge fixtures, and occupancy sensors. This innovative program is one of the largest in the country and has achieved over 6,000 installations). In this paper, we will review why PCBs are classified as hazardous substances and what effect State and Federal regulations have on the transportation and disposal of ballasts that contain PCBs. Second, we will explain our ballast disposal process which includes collecting, processing, storing, shipping and ultimate disposal. Third, we will discuss our experiences with two different methods of disposal - incineration and recycling. And last we will report on program results

  7. The 1986 residential occupant survey

    Energy Technology Data Exchange (ETDEWEB)

    Ivey, D.L.; Alley, P.K.

    1987-04-01

    In 1986, Pacific Northwest Laboratory developed the Residential Occupant Survey-Spring '86, which was implemented. The overall purpose of the study was to collect demographic, attitudinal, and behavioral data related to the use and conservation of electricity in dwellings participating in the Bonneville Power Administration's End-Use Load and Conservation Assessment Program (ELCAP). Information was collected on the respondents' perceptions of the energy efficiency of their dwelling, temperature the dwelling was kept when people were at home and awake during the last heating season, which rooms, if any, were not heated during the last heating season, number of times the dwelling was unoccupied for at least one week, number of times pets were let out of the dwelling per day, attitudes toward energy use and conservation and several socio-demographic variables such as age, sex, and total household income. The results of the data analyses showed age to be an important factor for reported indoor temperature and perceived energy efficiency of the dwelling. The results also showed that almost 60% of the ELCAP occupants do not heat one or more rooms during the heating season, and almost 45% of the ELCAP dwellings were unoccupied for at least one week during the reporting period. In terms of the reported allocation of household income for household energy expenses, the results showed that the reported dollar amount spent for the expenses remained relatively constant over income levels.

  8. Protection of Hawaii's Observatories from Light Pollution

    Science.gov (United States)

    Wainscoat, Richard J.

    2018-01-01

    Maunakea Observatory, located on the island of Hawaii, is among the world darkest sites for astronomy. Strong efforts to preserve the dark night sky over the last forty years have proven successful. Artificial light presently adds only approximately 2% to the natural night sky brightness. The techniques being used to protect Maunakea from light pollution will be described, along with the challenges that are now being faced.Haleakala Observatory, located on the island of Maui, is also an excellent observing site, and is among the best sites in the United States. Lighting restrictions in Maui County are much weaker, and consequently, the night sky above Haleakala is less well protected. Haleakala is closer to Honolulu and the island of Oahu (population approximately 1 million), and the glow from Oahu makes the northwestern sky brighter.Much of the lighting across most of the United States, including Hawaii, is presently being converted to LED lighting. This provides an opportunity to replace existing poorly shielded lights with properly shielded LED fixtures, but careful spectral management is essential. It is critically important to only use LED lighting that is deficient in blue and green light. LED lighting also is easy to dim. Dimming of lights later at night, when there is no need for brighter lighting, is an important tool for reducing light pollution.Techniques used to protect astronomical observatories from light pollution are similar to the techniques that must be used to protect animals that are affected by light at night, such as endangered birds and turtles. These same techniques are compatible with recent human health related lighting recommendations from the American Medical Association.

  9. Differences between Residential and Non-Residential Fathers on Sexual Socialisation of African American Youth

    Science.gov (United States)

    Sneed, Carl D.; Willis, Leigh A.

    2016-01-01

    This study investigated differences between residential and non-residential fathers on topics discussed during father-child sex communication and factors associated with child sexual socialisation. Young people (N = 159, 53% female) provided self-reports using computer surveys on the role of their fathers on father-child sex communication, general…

  10. Light transmission and air used for inspection of glovebox gloves

    International Nuclear Information System (INIS)

    Castro, Julio M.; Steckle, Warren P. Jr.; Macdonald, John M.

    2002-01-01

    Various materials used for manufacturing the glovebox gloves are translucent material such as hypalon, rubbers, and neoprene. This means that visible light can be transmitted through the inside of the material. Performing this test can help to increase visualization of the integrity of the glove. Certain flaws such as pockmarks, foreign material, pinholes, and scratches could be detected with increased accuracy. An analysis was conducted of the glovebox gloves obscure polymer material using a inspection light table. The fixture is equipped with a central light supply and small air pump to inflate the glove and test for leak and stability. A glove is affixed to the fixture for 360-degree inspection. Certain inspection processes can be performed: (1) Inspection for pockmarks and thin areas within the gloves; (2) Observation of foreign material within the polymer matrix; and (3) Measurements could be taken for gloves thickness using light measurements. This process could help reduce eyestrain when examining gloves and making a judgment call on the size of material thickness in some critical areas. Critical areas are fingertips and crotch of fingers.

  11. Optimal tree design for daylighting in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hongbing, Wang [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China); Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Jun, Qin; Yonghong, Hu [Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Li, Dong [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China)

    2010-12-15

    Urban reforestation is advocated as an efficient countermeasure to the intensification of urban heat islands. The greening and beautification of residential quarters is one of the main concerns of residents, while lighting and ventilation are two main energy-consuming building services. Hence, the tree layout in green space between buildings is important, and it is necessary to determine the relationships between trees and buildings. This study takes Shanghai as a case study to optimize tree design between residential buildings and meet good daylighting requirements. Models were made using software such as AutoCAD and SketchUp. The relationships between maximum tree height and building separation were determined. For the same building layout, there were different tree height limits according to crown shape; the order of decreasing height limits was cylindrical, conical, spherical, and inverted conical crowns. Three cases having different green space between building layouts were studied. Their maximum tree heights differed. Overall, our model helps us realize good daylighting of a building environment. The formula allows us to determine which trees to plant between buildings in that we can predict the effects of future tree growth on building daylighting. (author)

  12. Integration of fuel cells into residential buildings

    International Nuclear Information System (INIS)

    Bell, J.M.; Entchev, E.; Gusdorf, J.; Szadkowski, F.; Swinton, M.; Kalbfleisch, W.; Marchand, R.

    2004-01-01

    Integration of small combined heat and power systems (CHP) into residential buildings is challenging as the loads are small, the load diversity is limited and there are a number of unresolved issues concerning sizing, control, peak loads, emergency operation, grid connection and export, etc. Natural Resources Canada has undertaken an initiative to investigate and develop techniques for the integration of small CHP systems into residential buildings using a highly instrumented house modified to allow quick installation and thorough monitoring of CHP integration techniques as well determining the performance of the CHP systems themselves when operating in a house. The first CHP system installed was a Stirling engine residential CHP system. It was used to examine the completeness of the CHP modifications to the house, to evaluate various building integration techniques and to measure the performance of the CHP system itself. The testing demonstrated the modified house to be an excellent facility for the development of CHP building integration techniques and the testing of residential CHP systems. The Stirling engine CHP system was found to operate well and produce meaningful input to the house. A second system (residential fuel cell) is presently being installed and building integration techniques and the performance of the fuel cell will be tested over the coming year. (author)

  13. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  14. Residentialization of Public Spaces: Bratislava Example

    Science.gov (United States)

    Bacová, Andrea; Puškár, Branislav; Vráblová, Edita

    2017-10-01

    The housing estates in Bratislava saturated the housing needs of a large number of inhabitants who come after World War II to the city. Design of public spaces often did not have priority in the process of designing. The solutions for mentioned exterior spaces had been planned after blocks of flat realization, but many of them are not realized to this day. The article analyzes the example of the unrealized public spaces in existing housing estates Devinska Nova Ves and Petržalka (city districts of Bratislava) and offer practical solutions in relation to residencialization method. Residencialization of missing public places is an effective method of adding identities to settlements. It improves the quality of residential environment and public spaces. The main aim is to create better conditions for social activities in public areas, which are missing on the present. The research will be focused on the examination of the urban, cultural and construction potential of the existing residential enviroment in Bratislava. The main aim of residentialization is not only to enhance the quality of spatial and building structures in the selected residential area and maintain long-term sustainability in the pertinent programme area, but mainly to improve the quality of living for the residents. The outputs of the project are proposals and practical procedures developed with regard to planning documents for local municipal authorities and regional organizations. The solutions will have a positive impact on the enhancement of the quality of public spaces, attractive social activities and of a conceptual link - residentialization.

  15. Qualifying lighting remodelling in a Hungarian city based on light pollution effects

    International Nuclear Information System (INIS)

    Kolláth, Z.; Dömény, A.; Kolláth, K.; Nagy, B.

    2016-01-01

    The public lighting system has been remodelled in several Hungarian cities. In some cases the majority of the old luminaries were fitted with high pressure sodium lamps and they were replaced with white LED lighting with a typical correlated colour temperature of about 4500 K. Therefore, these remodelling works provide a testbed for methods in measurements and modelling. We measured the luminance of the light domes of selected cities by DSLR photometry before and after the remodelling. Thanks to the full cut off design of the new lighting fixtures we obtained a slight decrease even in the blue part of the sky dome spectra of a tested city. However, we have to note that this positive change is the result of the bad geometry (large ULR) of the previous lighting system. Based on Monte Carlo radiative transfer calculations we provide a comparison of different indicators that can be used to qualify the remodelling, and to predict the possible changes in light pollution. - Highlights: • Changes of the skydome of a Hungarian city were measured after lighting remodelling. • The observations were compared with Monte Carlo radiation transfer calculations. • Photopic measurements demonstrate improvement in light pollution after remodelling. • However, blue rich lighting increases the risk of negative ecological effects.

  16. Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure.

    Science.gov (United States)

    Norton, M R

    1998-04-01

    The concept of a conical implant design to accommodate single tooth replacement, has previously been shown to result in excessive bone loss, around the machined titanium conical collar, usually down to the 1st thread. This unusually aggressive loss of bone was shown to occur within a short period of time, post loading, with greater than 3 mm of bone loss occurring within the 1st 6 months to 1 year. The influence of implant design, surface texture and microleakage have all been highlighted as a potential cause. A modification of the surface structure, both at the macroscopic and microscopic level, as well as an altered fixture-abutment interface design has resulted in the maintenance of marginal bone around a single tooth titanium implant with a similar conical design. The radiographic follow-up of 33 implants loaded for up to 4 years, has revealed, by comparison, a most favourable maintenance of marginal bone around the conical collar, with a mean marginal bone loss of 0.32 mm mesially and 0.34 mm distally for the whole group. The cumulative mean marginal bone loss mesially and distally is 0.42 mm and 0.40 mm from 1 to 2 years, 0.54 mm and 0.43 mm from 2 to 3 years, 0.51 mm and 0.24 mm from 3 to 4 years, and 0.62 mm and 0.60 mm for implants past their 4 year recall.

  17. Development of Client-Server Application by Using UDP Socket Programming for Remotely Monitoring CNC Machine Environment in Fixture Process

    Directory of Open Access Journals (Sweden)

    Darmawan Darmawan

    2016-08-01

    Full Text Available The use of computer technology in manufacturing industries can improve manufacturing flexibility significantly, especially in manufacturing processes; many software applications have been utilized to improve machining performance. However, none of them has discussed the abilities to perform direct machining. In this paper, an integrated system for remote operation and monitoring of Computer Numerical Control (CNC machines is put into consideration. The integrated system includes computerization, network technology, and improved holding mechanism. The work proposed by this research is mainly on the software development for such integrated system. It uses Java three-dimensional (3D programming and Virtual Reality Modeling Language (VRML at the client side for visualization of machining environment. This research is aimed at developing a control system to remotely operate and monitor a self-reconfiguration fixture mechanism of a CNC milling machine through internet connection and integration of Personal Computer (PC-based CNC controller, a server side, a client side and CNC milling. The performance of the developed system was evaluated by testing with one type of common protocols particularly User Datagram Protocol (UDP.  Using UDP, the developed system requires 3.9 seconds to complete the close clamping, less than 1 second to release the clamping and it can deliver 463 KiloByte.

  18. Estimation of energy efficiency of residential buildings

    Directory of Open Access Journals (Sweden)

    Glushkov Sergey

    2017-01-01

    Full Text Available Increasing energy performance of the residential buildings by means of reducing heat consumption on the heating and ventilation is the last segment in the system of energy resources saving. The first segments in the energy saving process are heat producing and transportation over the main lines and outside distribution networks. In the period from 2006 to 2013. by means of the heat-supply schemes optimization and modernization of the heating systems. using expensive (200–300 $US per 1 m though hugely effective preliminary coated pipes. the economy reached 2.7 mln tons of fuel equivalent. Considering the multi-stage and multifactorial nature (electricity. heat and water supply of the residential sector energy saving. the reasonable estimate of the efficiency of the saving of residential buildings energy should be performed in tons of fuel equivalent per unit of time.

  19. Residential neighbourhoods in Kathmandu: Key design guidelines

    Directory of Open Access Journals (Sweden)

    Bijaya K. Shrestha

    2013-01-01

    Full Text Available Residential neighbourhoods developed using various techniques in Kathmandu by both the public and private sectors have not only provided a poor urban setting and failed to address socio-cultural needs, but are also poor at building a community and creating links to the built environment, with the result that the planned areas lack a sense of place and the inhabitants lack a feeling of home. Although traditional neighbourhoods in the historic core area had many features of a good residential neighbourhood in the past, they are currently undergoing rapid destruction. The residents of these neighbourhoods have little awareness of these issues. The existing legal and institutional frameworks are inadequate and ineffective and cannot address these problems, and so the formulation of design guidelines, their strict implementation, and enhancement of socio-cultural events including social networking are recommended for future residential neighbourhood development.

  20. Expressions of Prayer in Residential Care Homes.

    Science.gov (United States)

    Reimer-Kirkham, Sheryl; Sharma, Sonya; Smith, Brenda; Schutt, Kelly; Janzen, Kyla

    2018-01-01

    Although the value of spiritual care in the care of older adults is supported by research, few studies have focused specifically on prayer in residential care settings. This ethnographic study with fifteen chaplains and administrators in eleven residential care homes involved analyses of walking interviews and research diaries. Findings revealed the spaces in which prayer happens and the forms it takes. The identities of chaplains-their own spiritual practices, religious beliefs, and positioning within the facility-shaped their dis/comfort with prayer and how they located prayer within public and private spaces. Where organizational leadership endorsed the legitimacy of chaplaincy services, prayer was more likely to be offered. Even in these circumstances, however, religious diversity and questions about secularism left chaplains ambivalent about the appropriateness of prayer. The results demonstrate the relevance of religion and spirituality to residential care, and illustrate how prayer functions as an opportunity for connection and understanding.

  1. Service Differentiation in Residential Broadband Networks

    DEFF Research Database (Denmark)

    Sigurdsson, Halldór Matthias

    2004-01-01

    As broadband gains widespread adoption with residential users, revenue generating voice- and video-services have not yet taken off. This slow uptake is often attributed to lack of Quality of Service management in residential broadband networks. To resolve this and induce service variety, network...... access providers are implementing service differentiation in their networks where voice and video gets prioritised before data. This paper discusses the role of network access providers in multipurpose packet based networks and the available migration strategies for supporting multimedia services...... in digital subscriber line (DSL) based residential broadband networks. Four possible implementation scenarios and their technical characteristics and effects are described. To conclude, the paper discusses how network access providers can be induced to open their networks for third party service providers....

  2. Solar Photovoltaic Financing: Residential Sector Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.; Cory, K.

    2009-03-01

    This report presents the information that homeowners and policy makers need to facilitate PV financing at the residential level. The full range of cash payments, bill savings, and tax incentives is covered, as well as potentially available solar attribute payments. Traditional financing is also compared to innovative solutions, many of which are borrowed from the commercial sector. Together, these mechanisms are critical for making the economic case for a residential PV installation, given its high upfront costs. Unfortunately, these programs are presently limited to select locations around the country. By calling attention to these innovative initiatives, this report aims to help policy makers consider greater adoption of these models to benefit homeowners interested installing a residential PV system.

  3. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  4. Modelling and forecasting Turkish residential electricity demand

    International Nuclear Information System (INIS)

    Dilaver, Zafer; Hunt, Lester C

    2011-01-01

    This research investigates the relationship between Turkish residential electricity consumption, household total final consumption expenditure and residential electricity prices by applying the structural time series model to annual data over the period from 1960 to 2008. Household total final consumption expenditure, real energy prices and an underlying energy demand trend are found to be important drivers of Turkish residential electricity demand with the estimated short run and the long run total final consumption expenditure elasticities being 0.38 and 1.57, respectively, and the estimated short run and long run price elasticities being -0.09 and -0.38, respectively. Moreover, the estimated underlying energy demand trend, (which, as far as is known, has not been investigated before for the Turkish residential sector) should be of some benefit to Turkish decision makers in terms of energy planning. It provides information about the impact of past policies, the influence of technical progress, the impacts of changes in consumer behaviour and the effects of changes in economic structure. Furthermore, based on the estimated equation, and different forecast assumptions, it is predicted that Turkish residential electricity demand will be somewhere between 48 and 80 TWh by 2020 compared to 40 TWh in 2008. - Research highlights: → Estimated short run and long run expenditure elasticities of 0.38 and 1.57, respectively. → Estimated short run and long run price elasticities of -0.09 and -0.38, respectively. → Estimated UEDT has increasing (i.e. energy using) and decreasing (i.e. energy saving) periods. → Predicted Turkish residential electricity demand between 48 and 80 TWh in 2020.

  5. The positioning of sustainability within residential property marketing.

    Science.gov (United States)

    Kriese, Ulrich; Scholz, Roland W

    2011-01-01

    This article investigates the evolution of sustainability positioning in residential property marketing to shed light on the specific role and responsibility of housebuilders and housing investors in urban development. To this end, an analysis is made of housing advertisements published in Basel, Switzerland, over a period of more than 100 years. The paper demonstrates how to draw successfully on advertisements to discern sustainability patterns in housing, using criteria situated along the dimensions building, location and people. Cluster analysis allows five clusters of sustainability positioning to be described—namely, good location, green building, comfort living, pre-sustainability and sustainability. Investor and builder types are differently located in these clusters. Location emerges as an issue which, to a large extent, is advertised independently from other sustainability issues.

  6. The residential segregation patterns of whites by socioeconomic status, 2000–2011

    OpenAIRE

    Sharp, Gregory; Iceland, John

    2013-01-01

    In light of increasing racial and ethnic diversity, a recent housing crisis, and deep economic recession, arguments pertaining to the role of socioeconomic status (SES) in shaping patterns of racial/ethnic segregation remain salient. Using data from the 2000 decennial census and the 2007–2011 American Community Survey, we provide new evidence on the residential segregation patterns of whites from minorities by SES (income, education, and poverty). Results from our comprehensive analyses indic...

  7. Sustainable residential districts : the residents' role in project success

    NARCIS (Netherlands)

    Abdalla, G.

    2012-01-01

    Sustainable residential districts have been realized worldwide. These districts are promoted to be efficient in the use of natural materials and sustainable energy resources. Realization of sustainable residential districts can strongly contribute to achieve environmental objectives as imposed by

  8. PRN 2011-1: Residential Exposure Joint Venture

    Science.gov (United States)

    This PR Notice is to advise registrants of an industry-wide joint venture, titled the Residential Exposure Joint Venture (REJV), which has developed a national survey regarding residential consumer use/usage data for pesticides.

  9. Steering Angle Function Algorithm of Morphing of Residential Area

    Directory of Open Access Journals (Sweden)

    XIE Tian

    2015-07-01

    Full Text Available A residential area feature morphing method based on steering angle function is presented. To residential area with the same representation under two different scales,transforming the representation of the residential area polygon from vector coordinates to steering angle function,then using the steering angle function to match,and finding out the similarity and the differences between the residential areas under different scale to get the steering angle function of the the residential areas under any middle scale,the final,transforming the middle scale steering angle function to vector coordinates form,and get the middle shape interpolation of the the residential area polygon.Experimental results show:the residential area morphing method by using steering angle function presented can realize the continuous multi-scale representation under the premise of keeping in shape for the residential area with the rectangular boundary features.

  10. Solar access of residential rooftops in four California cities

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Pomerantz, Melvin

    2010-05-14

    Shadows cast by trees and buildings can limit the solar access of rooftop solar-energy systems, including photovoltaic panels and thermal collectors. This study characterizes residential rooftop shading in Sacramento, San Jose, Los Angeles and San Diego, CA. Our analysis can be used to better estimate power production and/or thermal collection by rooftop solar-energy equipment. It can also be considered when designing programs to plant shade trees. High-resolution orthophotos and LiDAR (Light Detection And Ranging) measurements of surface height were used to create a digital elevation model of all trees and buildings in a well-treed 2.5-4 km{sup 2} residential neighborhood. On-hour shading of roofing planes (the flat elements of roofs) was computed geometrically from the digital elevation model. Values in future years were determined by repeating these calculations after simulating tree growth. Parcel boundaries were used to determine the extent to which roofing planes were shaded by trees and buildings in neighboring parcels. For the subset of S+SW+W-facing planes on which solar equipment is commonly installed for maximum solar access, absolute light loss in spring, summer and fall peaked about two to four hours after sunrise and about two to four hours before sunset. The fraction of annual insolation lost to shading increased from 0.07-0.08 in the year of surface-height measurement to 0.11-0.14 after 30 years of tree growth. Only about 10% of this loss results from shading by trees and buildings in neighboring parcels.

  11. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  12. Suggestions on Strengthening Greening Construction of Ecological Residential Areas

    OpenAIRE

    Li, Peng

    2013-01-01

    Greening construction is an important part of the construction of ecological residential areas, but there exist some misunderstandings in greening construction of ecological residential districts at present. Based on the description of functions of green space in ecological residential areas, the summarization of principles of greening design, and the discussion of questions in greening construction of ecological residential districts, some suggestions as well as specific measures for strengt...

  13. The evaluation of retrofit measures in a tall residential building

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, M.M.; McLain, H.A.

    1995-07-01

    As part of a joint demonstration effort involving the US Department of Energy (DOE), the US Department of Housing and Urban Development (HUD), Boston Edison Company (BECo), and the Chelsea Housing Authority, Oak Ridge National Laboratory (ORNL) participated in the evaluation of energy and demand saving retrofits for a tall residential building located in Boston. The thirteen story all-electric building underwent window, lighting, and control renovations in December, 1992. annual energy consumption was reduced by 15% and peak demand fell by 17%. Hourly should building consumption data were available for the comparison of pre- and post- conditions and for calibration of a DOE-2.1D simulation model. The analysis found the window retrofit accounted for 90% of total energy savings and 95% of average demand savings, due to reductions in both conduction and infiltration. Benefits from lighting retrofits were low in cooling months and negligible in winter months due to the increase in the demand for electric resistance heating which was proportional to the reduction in lighting capacity. Finally, the simulation model verified that heating system controls had not been used as intended, and that the utility rate structure would not allow cost savings from the original control strategy. These results and other interesting lessons learned are presented.

  14. 24 CFR 40.2 - Definition of “residential structure”.

    Science.gov (United States)

    2010-04-01

    ... OWNED RESIDENTIAL STRUCTURES § 40.2 Definition of “residential structure”. (a) As used in this part, the term residential structure means a residential structure (other than a privately owned residential structure and a residential structure on a military reservation): (1) Constructed or altered by or on behalf...

  15. Residential Preferences and Moving Behavior: A Family Life Cycle Analysis.

    Science.gov (United States)

    McAuley, William J.; Nutty, Cheri L.

    The relationship of family life cycle changes to housing preferences and residential mobility is examined. Two residential decision-making issues are explored in detail--how family life cycle stages influence what people view as important to their choice of residential setting and what individuals at different family life cycle stages view as the…

  16. 38 CFR 36.4357 - Combination residential and business property.

    Science.gov (United States)

    2010-07-01

    ... Reporting § 36.4357 Combination residential and business property. If otherwise eligible, a loan for the purchase or construction of a combination of residential property and business property which the veteran... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Combination residential...

  17. Family events and the residential mobility of couples

    NARCIS (Netherlands)

    Michielin, F.; Mulder, C.H.

    2008-01-01

    Using data from retrospective surveys carried out in the Netherlands during the early 1990s, we describe how the residential mobility of couples—that is, short-distance moves—is affected by family events and how fertility is affected by residential mobility. The results show that residential moves

  18. Opportunities and challenges for 3D printing of solid-state lighting systems

    Science.gov (United States)

    Narendran, Nadarajah; Perera, Indika U.; Mou, Xi; Thotagamuwa, Dinusha R.

    2017-09-01

    Low energy use and reduced maintenance have made the LED, a solid-state light (SSL) source, the preferred technology for many lighting applications. With the explosion of products in the marketplace and subsequent price erosion, manufacturers are looking for lower cost materials and manufacturing methods. 3-D printing, also known as additive manufacturing, could be a potential solution. Recently, manufacturers in the automotive, aerospace, and medical industries have embraced 3-D printing for manufacturing parts and systems. This could pave the way for the lighting industry to produce lower cost, custom lighting systems that are 3-D printed on-site to achieve on-time and on-demand manufacturing. One unique aspect of LED fixture manufacturing is that it requires thermo-mechanical, electrical, and optical components. The goal of our investigation was to understand if current 3-D printing technologies and materials can be used to manufacture functional thermo-mechanical, electrical, and optical components for SSL fixtures. We printed heat sink components and electrical traces using an FFF-type 3-D printer with different filaments. The results showed that the printed heat sinks achieved higher thermal conductivity values compared to components made with plastic materials. For electrical traces, graphene-infused PLA showed low resistivity but it is much higher than bulk copper resistivity. For optics, SLA-printed optical components showed that print resolution, print orientation, and postprocessing affect light transmission and light scatter properties. Overall, 3-D printing offers an opportunity for mass customization of SSL fixtures and changing architectural lighting practice, but several challenges in terms of process and materials still have to be overcome.

  19. Hydrological processes at the urban residential scale

    Science.gov (United States)

    Q. Xiao; E.G. McPherson; J.R. Simpson; S.L. Ustin

    2007-01-01

    In the face of increasing urbanization, there is growing interest in application of microscale hydrologic solutions to minimize storm runoff and conserve water at the source. In this study, a physically based numerical model was developed to understand hydrologic processes better at the urban residential scale and the interaction of these processes among different...

  20. Does Fall History Influence Residential Adjustments?

    Science.gov (United States)

    Leland, Natalie; Porell, Frank; Murphy, Susan L.

    2011-01-01

    Purpose of the study: To determine whether reported falls at baseline are associated with an older adult's decision to make a residential adjustment (RA) and the type of adjustment made in the subsequent 2 years. Design and Methods: Observations (n = 25,036) were from the Health and Retirement Study, a nationally representative sample of…

  1. Condition assessment and strengthening of residential units

    Directory of Open Access Journals (Sweden)

    Tatheer Zahra

    2014-01-01

    Full Text Available About 40, ground plus one (G+1 residential units were designed using a hybrid structural framing system (RC frame and load bearing walls. A few months after the completion of the ground floor of the residential units, cracks appeared at several locations in the structure. Field and Laboratory testing was conducted to ascertain the in situ strength of concrete and steel reinforcement. The results of the experimental work were used in the analytical ETABS model for the structural stability calculations. The results indicated that residential units were marginally safe in the existing condition (completed ground floor, but the anticipated construction of the floor above the ground floor (G+1 could not be carried out as the strength of the structural system was inadequate. To increase the safety of existing ground floor and to provide the option of the construction of one floor above, rehabilitation and strengthening design was performed. The proposed strengthening design made use of welded wire fabric (WWF and carbon fibre reinforced polymer (CFRP laminates/sheets for the strengthening of walls, columns and slabs. The residential units will be strengthened in the near future.

  2. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  3. Employee influenza vaccination in residential care facilities.

    Science.gov (United States)

    Apenteng, Bettye A; Opoku, Samuel T

    2014-03-01

    The organizational literature on infection control in residential care facilities is limited. Using a nationally representative dataset, we examined the organizational factors associated with implementing at least 1 influenza-related employee vaccination policy/program, as well as the effect of vaccination policies on health care worker (HCW) influenza vaccine uptake in residential care facilities. The study was a cross-sectional study using data from the 2010 National Survey of Residential Care Facilities. Multivariate logistic regression analysis was used to address the study's objectives. Facility size, director's educational attainment, and having a written influenza pandemic preparedness plan were significantly associated with the implementation of at least 1 influenza-related employee vaccination policy/program, after controlling for other facility-level factors. Recommending vaccination to employees, providing vaccination on site, providing vaccinations to employees at no cost, and requiring vaccination as a condition of employment were associated with higher employee influenza vaccination rates. Residential care facilities can improve vaccination rates among employees by adopting effective employee vaccination policies. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  4. DETERMINANTS OF RESIDENTIAL PER CAPITA WATER ...

    African Journals Online (AJOL)

    This report presents the findings of the study on the determinants of residential per capita water demand of Makurdi metropolis in Benue State, Nigeria. Data for the study was obtained by the use of questionnaires, oral interviews and observations. The data was analyzed using SPSS. Twenty variables were considered in ...

  5. Consumer Decision Rules and Residential Finance.

    Science.gov (United States)

    Brandt, Jeanette A.; Jaffe, Austin J.

    1979-01-01

    As guidelines for residential financing, the authors compare different approaches to understanding and figuring the costs of home ownership: the relation of income to house price and housing costs, interest rate, and mortgage term. Instead of the traditional method, they recommend the time value of money approach. (MF)

  6. Information Processing and Creative Thinking Abilities of Residential and Non-Residential School Children

    Directory of Open Access Journals (Sweden)

    Atasi Mohanty

    2015-10-01

    Full Text Available This study attempts to assess and compare the residential and non-residential schoolchildren in information-processing skills and creative thinking abilities. A sample of 80 children from Classes 5 and 7 were selected from two types of schools, residential/ashram (02 and non-residential/formal schools (02 in Bolpur subdivision of West Bengal in India where the medium of instruction is Bengali language/mother-tongue. All the children were individually administered the PASS (Planning, Attention, Simultaneous, Successive, Stroop, Matching Familiar Figure Test (MFFT-20, and creative thinking tasks. The residential school children were found to perform better both in information processing and creative thinking tasks. The developmental trend could not be clearly observed due to small sample size, but with increasing age, children were using better processing strategies. Due to ashram environment, creative pedagogy, and various co-curricular activities, the residential school children were found to be more creative than their formal school counterparts. Moreover, some significant positive correlations were found among information processing skills and creative thinking dimensions.

  7. Electric and gas utility marketing of residential energy conservation case studies

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    The objective of this research was to obtain information about utility conservation marketing techniques from companies actively engaged in performing residential conservation services. Many utilities currently are offering comprehensive services (audits, listing of contractors and lenders, post-installation inspection, advertising, and performing consumer research). Activities are reported for the following utilities: Niagara Mohawk Power Corporation; Tampa Electric Company; Memphis Light, Gas, and Water Division; Northern States Power-Wisconsin; Public Service Company of Colorado; Arizona Public Service Company; Pacific Gas and Electric Company; Sacramento Municipal Utility District; and Pacific Power and Light Company.

  8. A Review of the Reflector Compact Fluorescent Lights Technology Procurement Program: Conclusions and Results

    Energy Technology Data Exchange (ETDEWEB)

    Sandahl, Linda J.; Gilbride, Theresa L.; Ledbetter, Marc R.; McCullough, Jeffrey J.

    2008-05-19

    This report describes a project sponsored by the U.S. Department of Energy (DOE) and implemented by the Pacific Northwest National Laboratory (PNNL), from 2000 to 2007 to improve the performance of reflector type (R-lamp) compact fluorescent lamps (CFLs) and increase their availability throughout the United States by means of a technology development and procurement strategy. In 2000, at the request of the U.S. Department of Energy’s Emerging Technologies Program and its predecessors, the Pacific Northwest National Laboratory undertook a technology procurement seeking R-CFLs that were specifically designed for use in ICAT recessed can fixtures and that met other minimum performance criteria including minimum light output and size restrictions (to ensure they fit in standard residential recessed cans). The technology procurement included two phases. In Phase I, requests for proposals (RFPs) were issued in October 2002 and five manufacturers responded with 12 lamp models. Eight of these models met the minimum requirements and passed the 6-hour short-term test in a simulated ICAT environment. These eight models were subjected to long-term tests of 6,000 or more hours in a simulated ICAT environment. Three of these models passed the short- and long-term tests and were promoted through the program website (www.pnl.gov/rlamps), press releases, and fliers. To increase the number of qualifying models, a second RFP was issued in June 2005. In April 2007, DOE announced that 16 reflector CFL (R-CFL) models by four manufacturers had met all the minimum requirements of Phase 2 of the R-CFL Technology Innovation Competition. PNNL developed both the criteria and the test apparatus design for Elevated Temperature Life Testing (ETLT), which has been included by DOE in its draft ENERGY STAR specifications for the reflector category of CFLs. PNNL promoted the winning lamps through a program website, press releases, and fliers as well as through program partners. PNNL also helped

  9. Electrodeless light source provided with radioactive material

    International Nuclear Information System (INIS)

    1979-01-01

    Radioactive materials are used to assist in starting a discharge in an electrodeless light source. The radioactive emissions predispose on the inner surface of the lamp envelope loosely bound charges which thereafter assist in initiating discharge. The radioactive material can be enclosed within the lamp envelope in gaseous or non-gaseous form. Preferred materials are krypton 85 and americium 241. In addition, the radioactive material can be dispersed in the lamp envelope material or can be a pellet imbedded in the envelope material. Finally, the radioactive material can be located in the termination fixture. Sources of alpha particles, beta particles, or gamma rays are suitable. Because charges accumulate with time on the inner surface of the lamp envelope, activity levels as low as 10 -8 curie are effective as starting aids. (Auth.)

  10. Research, Development and Demonstration of Micro-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Karl Mayer

    2010-03-31

    ECR International and its joint venture company, Climate Energy, are at the forefront of the effort to deliver residential-scale combined heat and power (Micro-CHP) products to the USA market. Part of this substantial program is focused on the development of a new class of steam expanders that offers the potential for significantly lower costs for small-scale power generation technology. The heart of this technology is the scroll expander, a machine that has revolutionized the HVAC refrigerant compressor industry in the last 15 years. The liquid injected cogeneration (LIC) technology is at the core of the efforts described in this report, and remains an excellent option for low cost Micro-CHP systems. ECR has demonstrated in several prototype appliances that the concept for LIC can be made into a practical product. The continuing challenge is to identify economical scroll machine designs that will meet the performance and endurance requirements needed for a long life appliance application. This report describes the numerous advances made in this endeavor by ECR International. Several important advances are described in this report. Section 4 describes a marketing and economics study that integrates the technical performance of the LIC system with real-world climatic data and economic analysis to assess the practical impact that different factors have on the economic application of Micro-CHP in residential applications. Advances in the development of a working scroll steam expander are discussed in Section 5. A rigorous analytical assessment of the performance of scroll expanders, including the difficult to characterize impact of pocket to pocket flank leakage, is presented in Section 5.1. This is followed with an FEA study of the thermal and pressure induced deflections that would result from the normal operation of an advanced scroll expander. Section 6 describes the different scroll expanders and test fixtures developed during this effort. Another key technical

  11. The effectiveness of environment assessment tools to guide refurbishment of Australian residential aged care facilities: A systematic review.

    Science.gov (United States)

    Neylon, Samantha; Bulsara, Caroline; Hill, Anne-Marie

    2017-06-01

    To determine applicability of environment assessment tools in guiding minor refurbishments of Australian residential aged care facilities. Studies conducted in residential aged care settings using assessment tools which address the physical environment were eligible for inclusion in a systematic review. Given these studies are limited, tools which have not yet been utilised in research settings were also included. Tools were analysed using a critical appraisal screen. Forty-three publications met the inclusion criteria. Ten environment assessment tools were identified, of which four addressed all seven minor refurbishment domains of lighting, colour and contrast, sound, flooring, furniture, signage and way finding. Only one had undergone reliability and validity testing. There are four tools which may be suitable to use for minor refurbishment of Australian residential aged care facilities. Data on their reliability, validity and quality are limited. © 2017 AJA Inc.

  12. Time series GHG emission estimates for residential, commercial, agriculture and fisheries sectors in India

    Science.gov (United States)

    Mohan, Riya Rachel

    2018-04-01

    Green House Gas (GHG) emissions are the major cause of global warming and climate change. Carbon dioxide (CO2) is the main GHG emitted through human activities, at the household level, by burning fuels for cooking and lighting. As per the 2006 methodology of the Inter-governmental Panel on Climate Change (IPCC), the energy sector is divided into various sectors like electricity generation, transport, fugitive, 'other' sectors, etc. The 'other' sectors under energy include residential, commercial, agriculture and fisheries. Time series GHG emission estimates were prepared for the residential, commercial, agriculture and fisheries sectors in India, for the time period 2005 to 2014, to understand the historical emission changes in 'other' sector. Sectoral activity data, with respect to fuel consumption, were collected from various ministry reports like Indian Petroleum and Natural Gas Statistics, Energy Statistics, etc. The default emission factor(s) from IPCC 2006 were used to calculate the emissions for each activity and sector-wise CO2, CH4, N2O and CO2e emissions were compiled. It was observed that the residential sector generates the highest GHG emissions, followed by the agriculture/fisheries and commercial sector. In the residential sector, LPG, kerosene, and fuelwood are the major contributors of emissions, whereas diesel is the main contributor to the commercial, agriculture and fisheries sectors. CO2e emissions have been observed to rise at a cumulative annual growth rate of 0.6%, 9.11%, 7.94% and 5.26% for the residential, commercial, agriculture and fisheries sectors, respectively. In addition to the above, a comparative study of the sectoral inventories from the national inventories, published by Ministry of Environment, Forest and Climate Change, for 2007 and 2010 was also performed.

  13. Residential applliance data, assumptions and methodology for end-use forecasting with EPRI-REEPS 2.1

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, R.J,; Johnson, F.X.; Brown, R.E.; Hanford, J.W.; Kommey, J.G.

    1994-05-01

    This report details the data, assumptions and methodology for end-use forecasting of appliance energy use in the US residential sector. Our analysis uses the modeling framework provided by the Appliance Model in the Residential End-Use Energy Planning System (REEPS), which was developed by the Electric Power Research Institute. In this modeling framework, appliances include essentially all residential end-uses other than space conditioning end-uses. We have defined a distinct appliance model for each end-use based on a common modeling framework provided in the REEPS software. This report details our development of the following appliance models: refrigerator, freezer, dryer, water heater, clothes washer, dishwasher, lighting, cooking and miscellaneous. Taken together, appliances account for approximately 70% of electricity consumption and 30% of natural gas consumption in the US residential sector. Appliances are thus important to those residential sector policies or programs aimed at improving the efficiency of electricity and natural gas consumption. This report is primarily methodological in nature, taking the reader through the entire process of developing the baseline for residential appliance end-uses. Analysis steps documented in this report include: gathering technology and market data for each appliance end-use and specific technologies within those end-uses, developing cost data for the various technologies, and specifying decision models to forecast future purchase decisions by households. Our implementation of the REEPS 2.1 modeling framework draws on the extensive technology, cost and market data assembled by LBL for the purpose of analyzing federal energy conservation standards. The resulting residential appliance forecasting model offers a flexible and accurate tool for analyzing the effect of policies at the national level.

  14. Deep Residential Retrofits in East Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Boudreaux, Philip R [ORNL; Hendrick, Timothy P [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

    2012-04-01

    Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is

  15. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment.

    Science.gov (United States)

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-09-25

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug

  16. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment

    Directory of Open Access Journals (Sweden)

    Yu-Jung Li

    2015-09-01

    Full Text Available A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis

  17. Program evaluation: Weatherization Residential Assistance Partnership (WRAP) Program

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-01

    The Connecticut low income weatherization program was developed in response to a 1987 rate docket order from the Connecticut Department of Public Utility Control (DPUC) to Connecticut Light Power Co., an operating subsidiary of Northeast Utilities (NU). (Throughout this report, NU is referred to as the operator of the program.) This program, known as the Weatherization Residential Assistance Partnership, or WRAP, was configured utilizing input from a collaborative group of interested parties to the docket. It was agreed that this program would be put forth by the electric utility, but would not ignore oil and gas savings (thus, it was to be fuel- blind''). The allocated cost of conservation services for each fuel source, however, should be cost effective. It was to be offered to those utility customers at or below 200 percent of the federal poverty levels, and provide a wide array of energy saving measures directed toward heating, water heating and lighting. It was felt by the collaborative group that this program would raise the level of expenditures per participant for weatherization services provided by the state, and by linking to and revising the auditing process for weatherization, would lower the audit unit cost. The program plans ranged from the offering of low-cost heating, water heating and infiltration measures, increased insulation levels, carpentry and plumbing services, to furnace or burner replacement. The program was configured to allow for very comprehensive weatherization and heating system servicing.

  18. Panethnicity, Ethnic Diversity and Residential Segregation

    Science.gov (United States)

    Kim, Ann H.; White, Michael J.

    2013-01-01

    We consider the theoretical and empirical implications of the structural basis of panethnicity and of the layering of ethnic boundaries in residential patterns while simultaneously evaluating the ‘panethnic hypothesis’, that is, the extent to which homogeneity within panethnic categories can be assumed. Our results do show a panethnic effect – greater residential proximity is evident within panethnic boundaries than between, net of ethnic group size and metropolitan area, but this association clearly depends on immigration. While findings generally show a lower degree of social distance between panethnic subgroups, particularly for blacks, whites and Latinos and less for Asians, ethno-national groups continue to maintain some degree of distinctiveness within a racialized context. PMID:20503650

  19. MICRO-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Gerstmann

    2009-01-31

    This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

  20. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  1. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  2. FACTOR ANALYSIS OF MULTISTOREY RESIDENTIAL BUILDINGS ZONE

    Directory of Open Access Journals (Sweden)

    Петр Матвеевич Мазуркин

    2016-02-01

    Full Text Available According to the UN classification of 11 classes of soil cover, the first three are grass, trees and shrubs and forests. In the city they correspond to the three elements of vegetation: lawns, tree plantings (trees and shrubs. We have adopted zoning for city-building to identify statistical regularities. Map dimensions in GIS "Map 2011" Yoshkar-Ola was allocated to "residential zone" and "Area of construction of multi-storey residential buildings (cadastral 58 quart crystals". The parameters of the elements of the vegetation cover have been considered: the number of elements of different levels, area and perimeter, the absolute and relative form, and activity of vegetation. As the result, we have obtained equations of binomial rank distributions, conducted the ratings and selected the best of cadastral quarter on environmental conditions.

  3. Electricity demand for South Korean residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Sa' ad, Suleiman [Surrey Energy Economics Centre (SEEC), Department of Economics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-12-15

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

  4. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  5. Adjustment problems and residential care environment

    Directory of Open Access Journals (Sweden)

    Jan Sebastian Novotný

    2015-01-01

    Full Text Available Problem: Residential care environment represents a specific social space that is associated with a number of negative consequences, covering most aspects of children and youth functioning. The paper analyzes of the presence of adjustment problems among adolescents from institutional care environment and compares this results with a population of adolescents who grew up in a family. Methods: The sample consisted of two groups of adolescents. The first group included 285 adolescents currently growing up in an residential care environment, aged 13 to 21 (M = 16.23, SD = 1.643. The second group consisted of 214 adolescents growing up in a family, aged 15 to 20 (M = 17.07, SD = 1.070. We used a questionnaire Youth Self Report. Data were analyzed using descriptive statistics and MANOVA. Results: Results showed that adolescents in residential care exhibit higher average values in all adjustment problems. Also, in the context of diagnostic categories are the residential care adolescents more frequently in non-normal range (borderline and clinical, primarily in the border range. The greatest differences were reflected in the Thought problems and Rule-breaking behavior. MANOVA showed a significant multivariate effect between groups of adolescents, Hotelling's T = .803, F(8, 490 = 49.202, p <.001, d = .445 (large effect. Univariate analysis further showed a significant effect for Withdrawn/depressed (p = .044, d = .089, small effect, Somatic complaints (p = .002, d = .139, medium effect, Social problems (p = 004, d = .127, a small effect, Thought problems (p <.001, d = .633, strong effect, Attention problems (p <.001, d = .320,strong effect, Rule-breaking behavior (p <.001 , d = .383, strong effect, and Aggressive behavior (p = 015, d = .110, small effect. Results for the dimension of Anxious/depressed were not significant (p = .159. Discussion: The results didn’t confirmed the assumption that more than 30% of residential care adolescents have adjustment

  6. Residential environmental evaluation of local cities considering regional characteristic and personal residential preference-a case study of Saga City,Japan

    Institute of Scientific and Technical Information of China (English)

    GE Jian; HOKAO Kazunori

    2004-01-01

    Questionnaire surveys and subjective evaluations on residential environment were performed in order to grasp the main factors of residential environment of small local cities. The suitable evaluation index system was established, and the regional residential environment characteristics and personal residential preference types were analyzed, so that their influence on residential environment evaluation could be grasped. The results can be applied to the residential environment planning, construction and monitoring of local cities.

  7. Transition issues in an unbundled residential market

    International Nuclear Information System (INIS)

    Brett, J.D.

    1996-01-01

    Aspects of an unbundled residential gas market were discussed, among them (1) the role of a local distribution company (LDC), (2) the context and the issues, (3) the customers'needs and desires, (4) long term planning responsibility, (5) consumer protection and dealing with abuses, (6) the obligation to serve, (7) the bad credit risk customer, (8) billing, credit and collection, and (9) metering and CIS

  8. Adjustment problems and residential care environment

    OpenAIRE

    Jan Sebastian Novotný

    2015-01-01

    Problem: Residential care environment represents a specific social space that is associated with a number of negative consequences, covering most aspects of children and youth functioning. The paper analyzes of the presence of adjustment problems among adolescents from institutional care environment and compares this results with a population of adolescents who grew up in a family. Methods: The sample consisted of two groups of adolescents. The first group included 285 adolescents currently g...

  9. INVESTIGATION OF ELECTROMAGNETIC FIELDS IN RESIDENTIAL AREAS

    Directory of Open Access Journals (Sweden)

    Dušan MEDVEĎ

    2017-09-01

    Full Text Available This article is devoted to investigation of impact of electromagnetic fields around the electrical equipment used in a residential area and their impact on the human body. This paper was based on sets of measurements of magnetic induction B with magnetometer and on computational simulations in ANSYS for particular appliances often used in household. The results from measurements and simulations led to setting out the recommendations for practical action in the form of elimination of harmful electromagnetic radiation.

  10. Development Of Economic Techniques For Residential Thermography

    Science.gov (United States)

    Allen, Lee R.; Allen, Sharon

    1983-03-01

    Infrared thermography has proven to be a valuable tool in the detection of heat loss in both commercial and residential buildings. The field of residential thermography has needed a simple method with which to report the deficiencies found during an infrared scan. Two major obstacles hindering the cost effectiveness of residential thermography have been 1) the ability to quickly transport some high resolution imaging system equipment from job site to job site without having to totally dismount the instruments at each area, and 2) the lack of a standard form with which to report the findings of the survey to the customer. Since the industry has yet to provide us with either, we believed it necessary to develop our own. Through trial and error, we have come up with a system that makes interior residential thermography a profitable venture at a price the homeowner can afford. Insulation voids, or defects can be instantly spotted with the use of a thermal imaging system under the proper conditions. A special hand-held device was developed that enables the thermographer to carry the equipment from house to house without the need to dismantle and set up at each stop. All the necessary components are attached for a total weight of about 40 pounds. The findings are then conveyed to a form we have developed. The form is simple enough that the client without special training in thermography can understand. The client is then able to locate the problems and take corrective measures or give it to a con-tractor to do the work.

  11. An Investigation into the Factors Affecting the Design of Nature-Compatible Recreational-Residential Complexes- Instance Analysis

    Directory of Open Access Journals (Sweden)

    Seyyedeh Fatemeh Safavi Mirmahalleh

    2017-02-01

    Full Text Available Explaining tourism concepts, standards of recreational-residential complexes and the methods for accurate treating with nature, this paper tries to study the suitable instances of recreational-residential complexes and to adopt their positive aspects as a design strategy. SWOT matrix was built based on the weaknesses and strengths of the project site and design principles were derived by observing the extracted influential factors. Considering land topography, for example, different areas of buildings were shifted and combined with the nature. - Residential and public zones gained a nice view towards the nature by keeping their orientation and extending them in east-west direction - Service section connected more appropriately with residential and public areas - Sections which do not need extra light such as W.Cs, storages and installation rooms, were considered in a side of the building which was adjacent to soil - In residential section, rhythm was implemented in ceilings and windows - Golden values and proportions were used to design the plane and façade of the complex

  12. Residential Treatment Centers for Child Abuse

    Directory of Open Access Journals (Sweden)

    Serhat Nasiroglu

    2014-02-01

    Full Text Available Every year millions of reports are being held and cases regarding those reports in courts are carrying on about abusement and omission against children . Abusement against children has been seen throughout of the history. Significant and permanent impacts can occur upon child abusement and neglect on victim children. It is important to know the psychological dynamics which have been lived by the children by the mental health professionalsto protect the children after the abusement report has been written. Cognitive Behaviour Therapy and medications are being used commonly in the treatment of abusement cases. However in some cases it is necessary to send away the victims from environment, enable them to continue their education life, make sure that they are treated by the professional individuals in safe area. For this end there are many Residential Treatment Centers around the world. and ldquo;Oguz Kagan Koksal Social Care and Rehabilitation Center and rdquo; was established in Adana as the first Residential Treatment Center in Turkey. In this report the historical dimensions of the child abusement, the definition of it, its psychological dynamics, the psychological disorders caused by it, treatment approaches and residential treatment centers have been reviewed. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2014; 6(1.000: 67-78

  13. Residential outage cost estimation: Hong Kong

    International Nuclear Information System (INIS)

    Woo, C.K.; Ho, T.; Shiu, A.; Cheng, Y.S.; Horowitz, I.; Wang, J.

    2014-01-01

    Hong Kong has almost perfect electricity reliability, the result of substantial investments ultimately financed by electricity consumers who may be willing to accept lower reliability in exchange for lower bills. But consumers with high outage costs are likely to reject the reliability reduction. Our ordered-logit regression analysis of the responses by 1876 households to a telephone survey conducted in June 2013 indicates that Hong Kong residents exhibit a statistically-significant preference for their existing service reliability and rate. Moreover, the average residential cost estimate for a 1-h outage is US$45 (HK$350), topping the estimates reported in 10 of the 11 studies published in the last 10 years. The policy implication is that absent additional compelling evidence, Hong Kong should not reduce its service reliability. - Highlights: • Use a contingent valuation survey to obtain residential preferences for reliability. • Use an ordered logit analysis to estimate Hong Kong's residential outage costs. • Find high outage cost estimates that imply high reliability requirements. • Conclude that sans new evidence, Hong Kong should not reduce its reliability

  14. Metal contamination in environmental media in residential ...

    Science.gov (United States)

    Hard-rock mining for metals, such as gold, silver, copper, zinc, iron and others, is recognized to have a significant impact on the environmental media, soil and water, in particular. Toxic contaminants released from mine waste to surface water and groundwater is the primary concern, but human exposure to soil contaminants either directly, via inhalation of airborne dust particles, or indirectly, via food chain (ingestion of animal products and/or vegetables grown in contaminated areas), is also, significant. In this research, we analyzed data collected in 2007, as part of a larger environmental study performed in the Rosia Montana area in Transylvania, to provide the Romanian governmental authorities with data on the levels of metal contamination in environmental media from this historical mining area. The data were also considered in policy decision to address mining-related environmental concerns in the area. We examined soil and water data collected from residential areas near the mining sites to determine relationships among metals analyzed in these different environmental media, using the correlation procedure in SAS statistical software. Results for residential soil and water analysis indicate that the average values for arsenic (As) (85 mg/kg), cadmium (Cd) (3.2 mg/kg), mercury (Hg) (2.3 mg/kg) and lead (Pb) (92 mg/kg) exceeded the Romanian regulatory exposure levels [the intervention thresholds for residential soil in case of As (25 mg/kg) and Hg

  15. Energy efficient residential house wall system

    International Nuclear Information System (INIS)

    Aldawi, Fayez; Date, Abhijit; Alam, Firoz; Khan, Iftekhar; Alghamdi, Mohammed

    2013-01-01

    The energy consumption and greenhouse gas emission by the residential housing sector are considered to be one of the largest in economically developed countries. The larger energy consumption and greenhouse gas emission not only put additional pressure on finite fossil fuel resources but also cause global warming and climate change. Additionally, the residential housing sector will be consuming more energy as the house demand and average house floor area are progressively increasing. With currently used residential house wall systems, it is hard to reduce energy consumption for ongoing house space heating and cooling. A smart house wall envelope with optimal thermal masses and insulation materials is vital for reducing our increasing energy consumption. The major aim of this study is to investigate thermal performance and energy saving potential of a new house wall system for variable climate conditions. The thermal performance modelling was carried out using commercially developed software AccuRate ® . The findings indicate that a notable energy savings can be accomplished if a smart house wall system is used. -- Highlights: • Smart house wall system. • Thermal performance modelling and star energy rating. • Energy savings and greenhouse gas reduction

  16. Coaxial test fixture

    Science.gov (United States)

    Praeg, Walter F.

    1986-01-01

    An assembly is provided for testing one or more contact material samples in a vacuum environment. The samples are positioned as an inner conductive cylinder assembly which is mounted for reciprocal vertical motion as well as deflection from a vertical axis. An outer conductive cylinder is coaxially positioned around the inner cylinder and test specimen to provide a vacuum enclosure therefor. A power source needed to drive test currents through the test specimens is connected to the bottom of each conductive cylinder, through two specially formed conductive plates. The plates are similar in form, having a plurality of equal resistance current paths connecting the power source to a central connecting ring. The connecting rings are secured to the bottom of the inner conductive assembly and the outer cylinder, respectively. A hydraulic actuator is also connected to the bottom of the inner conductor assembly to adjust the pressure applied to the test specimens during testing. The test assembly controls magnetic forces such that the current distribution through the test samples is symmetrical and that contact pressure is not reduced or otherwise disturbed.

  17. Load regulating expansion fixture

    International Nuclear Information System (INIS)

    Wagner, L.M.; Strum, M.J.

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located there between. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig

  18. Public lighting.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1986-01-01

    The function of public lighting and the relationship between public lighting and accidents are considered briefly as aspects of effective countermeasures. Research needs and recent developments in installation and operational described. Public lighting is an efficient accident countermeasure, but

  19. Light Pollution

    Science.gov (United States)

    Riegel, Kurt W.

    1973-01-01

    Outdoor lighting is light pollution which handicaps certain astronomical programs. Protective measures must be adopted by the government to aid observational astronomy without sacrificing legitimate outdoor lighting needs. (PS)

  20. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  1. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  2. Retailing residential electricity : A concept that makes sense?

    International Nuclear Information System (INIS)

    MacDonald, C.

    2003-07-01

    A heated debate centres around the deregulation of the electricity industry and the retailing of residential electricity. An assessment of the current situation in the industry was provided in this paper to provide a basis for discussion. The experience gained both in Alberta and Texas in residential retail was examined. The main issue of concern is whether residential customers will benefit from deregulation of the electricity sector. The Retail Energy Deregulation (RED) Index provides a benchmark for those jurisdictions considering the residential options. Deregulation has not led to significant benefits to residential customers in most jurisdictions. The electricity industry will always require a central dispatch/market process that will have to designed, governed, regulated, modified regularly. The benefits to residential consumers are not expected for a very long time. Standard market design is an issue that will require attention. refs., 7 figs

  3. Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge

    International Nuclear Information System (INIS)

    Kim, Do Hoon; Heo, Min Suk; Lee, Sam Sun; Oh, Sung Ook; Choi, Soon Chul; Choi, Hang Moon; Jeon, In Seong

    2003-01-01

    To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. The study materials considered of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the including rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  4. Flexible solar strips light up campus bus shelter at McMaster

    Energy Technology Data Exchange (ETDEWEB)

    Anon,

    2009-10-15

    This article described the installation of solar cells to illuminate a bus shelter on the campus of McMaster University. The innovative flexible solar cell technology was developed by a group of engineering researchers at the university who are hoping that the prototype will help commercialize the new technology. The solar technology is suitable for lighting up bus shelter signage and providing light for general safety. One of the main features of the technology is the ability to bend the solar cells to fit the curved roof of the bus shelter. The flexibility is achieved by tilting a large number of small silicon elements into an array, mounting them onto a flexible sheet, and connecting them through a proprietary method. The 2 solar strips installed on the roof of the bus shelter are about 90 centimeters long and 12 centimeters wide. Each strip has 720 one-centimetre square solar cells and generates up to 4.5 Watts of power. The solar strip is connected to 2 energy-efficient, multi-LED, light fixtures. Each light fixture uses only 600 milliwatts of power and produces about the same light output as a three watt regular tungsten bulb. The installation is being monitored to determine how much solar power is needed to fully recharge the batteries based on weather conditions, particularly during the winter months. 5 figs.

  5. WOW: light print, light propel, light point

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Bañas, Andrew Rafael; Aabo, Thomas

    2012-01-01

    anywhere in a sample at any orientation using real-time 3D optical micromanipulation with six degrees of freedom. One of the key aspects of our demonstrated WOWs is the change in direction of in-coupled light and the marked increase in numerical aperture of the out-coupled light. Hence, each light...... propelled WOW can tap from a relatively broad incident beam and generate a much more tightly confined light at its tip. The presentation contains both numerical simulations related to the propagation of light through a WOW and preliminary experimental demonstrations on our BioPhotonics Workstation...

  6. The drivers to adopt renewable energy among residential users.

    Science.gov (United States)

    Rahman, Zahari Abdul; Elinda, Esa

    2016-03-01

    This study aims to examine the drivers to adopt renewable energy (RE) among residential users in Malaysia. Based on the theoretical framework of a consumer’s decision making process, an empirical study of the adoption of RE was conducted. A total of 501 residential users were used in this study. This study proved that perceived utility of new technology, perceived utility of new service, and perceived benefit of new technology are the drivers to adopt RE among residential users. These factors are knowing crucial to RE suppliers and producers because it will generates more demand from the residential users and the percentage of energy mix from RE sources can be increase.

  7. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  8. Indoor Lighting Facilities

    Science.gov (United States)

    Matsushima, Koji; Saito, Yoshinori; Ichikawa, Shigenori; Kawauchi, Takao; Tanaka, Tsuneo; Hirano, Rika; Tazuke, Fuyuki

    According to the statistics on building construction floor area from the Ministry of Land, Infrastructure, Transport and Tourism, the total floor area of building construction started in Japan in 2007 was 160,991 thousand square meters, or 14.8% less than the area of the previous year, and the reduction was the first reduction in the past five years. The office markets in Tokyo and Nagoya were active, as represented by the supplies of skyscrapers, and energy saving measures, such as the adoption of high efficiency lighting equipment, the control for initial stage illuminance, daylight harvesting, and the use of occupancy sensors, were well established. In the field of public construction, including museums, multi-purpose halls, and religious buildings, the total area of the new construction was 10.8% less than the total for the previous year, and this reduction was a continuation of an eleven-year trend. In spaces with high ceiling, the innovation for easy replacement of light sources used with reflection mirror systems and optical fibers was noted. Hospitals adapted to the expectation for improved services in their selection of lighting facilities to improve the residential environment for patients while taking into consideration the needs of the aging population, by their use of devices in corridors to help maintain a continuity of light. In libraries, a pendant system was developed to illuminate both ceilings and book shelves. In the field of theaters and halls, the time limit for repairing existing systems had come for the large facilities that were opened during the theater and hall construction boom of the 1960s through 1980s, and around 26 renovations were done. Almost all the renovations were conversions to intelligent dimming systems and lighting control desks. In the field of stores and commercial facilities, the atmosphere and glitter of the selling floor was produced by new light sources, such as ceramic metal halide lamps and LEDs, which have high

  9. Light contamination

    International Nuclear Information System (INIS)

    Cepeda Pena, William Enrique

    1998-01-01

    The article tries on the wrong use of the artificial light, of the main problems of the light contamination, dispersion of the light, noxious effects of the light contamination, ecological effects, effects on the man's biological rhythm, economic effects and effects about the civic and vial security, among other topics

  10. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting at the I-35W Bridge, Minneapolis, MN

    Energy Technology Data Exchange (ETDEWEB)

    Kinzey, Bruce R.; Myer, Michael

    2009-08-31

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology conducted in 2009 at the recently reconstructed I-35W bridge in Minneapolis, MN. The project was supported under the U.S. Department of Energy (DOE) Solid-State Lighting GATEWAY Technology Demonstration Program. Other participants in the demonstration project included the Minnesota Department of Transportation (Mn/DOT), Federal Highways Administration (FHWA), and BetaLED™ (a division of Ruud Lighting). Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. DOE has implemented a three-year evaluation of the LED luminaires in this installation in order to develop new longitudinal field data on LED performance in a challenging, real-world environment. This document provides information through the initial phase of the I-35W bridge project, up to and including the opening of the bridge to the public and the initial feedback received on the LED lighting installation from bridge users. Initial findings of the evaluation are favorable, with minimum energy savings level of 13% for the LED installation relative to the simulated base case using 250W high-pressure sodium (HPS) fixtures. The LEDs had an average illuminance level of 0.91 foot candles compared to 1.29 fc for the HPS lamps. The LED luminaires cost $38,000 more than HPS lamps, yielding a lengthy payback period, however the bridge contractor had offered to include the LED luminaires as part of the construction package at no additional cost. One potentially significant benefit of the LEDs in this installation is avoiding rolling lane closures on the heavily-traveled interstate bridge for the purpose of relamping the HPS fixtures. Rolling lane closures involve multiple crew members and various maintenance and safety vehicles, diversion of traffic, as well as related administrative tasks (e.g., approvals, scheduling, etc.). Mn/DOT records show an average cost of

  11. Bullying in Adolescent Residential Care: The Influence of the Physical and Social Residential Care Environment

    Science.gov (United States)

    Sekol, Ivana

    2016-01-01

    Background: To date, no study examined possible contributions of environmental factors to bullying and victimization in adolescent residential care facilities. Objective: By testing one part of the Multifactor Model of Bullying in Secure Setting (MMBSS; Ireland in "Int J Adolesc Med Health" 24(1):63-68, 2012), this research examined the…

  12. Applying power electronics to residential HVAC

    International Nuclear Information System (INIS)

    Sulfstede, L.

    1991-01-01

    This paper outlines several of the market and application issues bearing on the economics residential variable speed air conditioners and heat pumps. Technical details of capacity modulized systems have been avoided, along with design issues and tradeoffs involving power semiconductors, motor torque and speed control strategies- and silicon integration for these applications. The intention is to provoke new creative technical solutions but perhaps more importantly, to involve new marketing strategies that will develop the mature potential of air conditioning products containing power electronics to enable them to generate the tough HVAC market, competing successfully against conventional systems

  13. Residential Energy Consumption Survey: Quality Profile

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The Residential Energy Consumption Survey (RECS) is a periodic national survey that provides timely information about energy consumption and expenditures of U.S. households and about energy-related characteristics of housing units. The survey was first conducted in 1978 as the National Interim Energy Consumption Survey (NIECS), and the 1979 survey was called the Household Screener Survey. From 1980 through 1982 RECS was conducted annually. The next RECS was fielded in 1984, and since then, the survey has been undertaken at 3-year intervals. The most recent RECS was conducted in 1993.

  14. Residential/commercial market for energy technologies

    Energy Technology Data Exchange (ETDEWEB)

    Glesk, M M

    1979-08-01

    The residential/commercial market sector, particularly as it relates to energy technologies, is described. Buildings account for about 25% of the total energy consumed in the US. Market response to energy technologies is influenced by several considerations. Some considerations discussed are: industry characteristics; market sectors; energy-consumption characeristics; industry forecasts; and market influences. Market acceptance may be slow or nonexistent, the technology may have little impact on energy consumption, and redesign or modification may be necessary to overcome belatedly perceived market barriers. 7 figures, 20 tables.

  15. Residential firewood use in the United States.

    Science.gov (United States)

    Lipfert, F W; Dungan, J L

    1983-03-25

    An empirical relation between residential firewood use and population density was developed from survey data for 64 counties in New England and was corroborated by data from other states. The results indicate that usage is concentrated in urbanized areas of the Northeast and north central states and that about 9.0 to 11.0 percent of U.S. space heating input is from firewood. No constraints due to the supply of wood were apparent in 1978-1979. These findings have implications for effects on air quality.

  16. Life-cycle energy of residential buildings in China

    International Nuclear Information System (INIS)

    Chang, Yuan; Ries, Robert J.; Wang, Yaowu

    2013-01-01

    In the context of rapid urbanization and new construction in rural China, residential building energy consumption has the potential to increase with the expected increase in demand. A process-based hybrid life-cycle assessment model is used to quantify the life-cycle energy use for both urban and rural residential buildings in China and determine the energy use characteristics of each life cycle phase. An input–output model for the pre-use phases is based on 2007 Chinese economic benchmark data. A process-based life-cycle assessment model for estimating the operation and demolition phases uses historical energy-intensity data. Results show that operation energy in both urban and rural residential buildings is dominant and varies from 75% to 86% of life cycle energy respectively. Gaps in living standards as well as differences in building structure and materials result in a life-cycle energy intensity of urban residential buildings that is 20% higher than that of rural residential buildings. The life-cycle energy of urban residential buildings is most sensitive to the reduction of operational energy intensity excluding heating energy which depends on both the occupants' energy-saving behavior as well as the performance of the building itself. -- Highlights: •We developed a hybrid LCA model to quantify the life-cycle energy for urban and rural residential buildings in China. •Operation energy in urban and rural residential buildings is dominant, varying from 75% to 86% of life cycle energy respectively. •Compared with rural residential buildings, the life-cycle energy intensity of urban residential buildings is 20% higher. •The life-cycle energy of urban residential buildings is most sensitive to the reduction of daily activity energy

  17. Residential normalcy and environmental experiences of very old people: changes in residential reasoning over time.

    Science.gov (United States)

    Granbom, Marianne; Himmelsbach, Ines; Haak, Maria; Löfqvist, Charlotte; Oswald, Frank; Iwarsson, Susanne

    2014-04-01

    The decision to relocate in old age is intricately linked to thoughts and desires to stay put. However, most research focuses either on strategies that allow people to age in place or on their reasons for relocation. There is a need for more knowledge on very old peoples' residential reasoning, including thoughts about aging in place and thoughts about relocation as one intertwined process evolving in everyday life. The aim of this study was to explore what we refer to as the process of residential reasoning and how it changes over time among very old people, and to contribute to the theoretical development regarding aging in place and relocation. Taking a longitudinal perspective, data stem from the ENABLE-AGE In-depth Study, with interviews conducted in 2003 followed up in interviews in 2011. The 16 participants of the present study were 80-89years at the time of the first interview. During analysis the Theoretical Model of Residential Normalcy by Golant and the Life Course Model of Environmental Experience by Rowles & Watkins were used as sensitizing concepts. The findings revealed changes in the process of residential reasoning that related to a wide variety of issues. Such issues included the way very old people use their environmental experience, their striving to build upon or dismiss attachment to place, and their attempts to maintain or regain residential normalcy during years of declining health and loss of independence. In addition, the changes in reasoning were related to end-of-life issues. The findings contribute to the theoretical discussion on aging in place, relocation as a coping strategy, and reattachment after moving in very old age. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Towards socially and economically sustainable urban developments : impacts of toll pricing on residential developments.

    Science.gov (United States)

    2013-12-01

    The goal of this research is to investigate the effects of road pricing on residential land use choices and to : help select pricing policies that foster socially and economically sustainable residential development in : urbanized residential areas. ...

  19. Spatial Pattern of Residential Carbon Dioxide Emissions in a Rapidly Urbanizing Chinese City and Its Mismatch Effect

    Directory of Open Access Journals (Sweden)

    Heli Lu

    2018-03-01

    Full Text Available Cities undergoing rapid urbanization are characterized by quick successions of spatiotemporal patterns, meaning that traditional methods cannot adequately assess carbon emissions from urban residential areas, which prevents the study of spatial mismatch. Therefore, this study utilizes night-time lights to construct a spatial emissions model that enables the analysis of the evolution of emissions patterns in China. The results indicate that, compared to the traditional method, the spatial modeling based on night-time lights reflects the spatial emissions trajectories in a more timely and accurate manner in rapidly urbanizing cities. Additionally, we found a relatively low degree of spatial match between emissions and economic activities, with the former, which are greatly affected by urbanization, having a larger dynamism and instability than the latter. Such spatial mismatch effect illustrates that policy makers should focus on factors beyond economics in order to reduce residential carbon emissions during China’s rapid urbanization process.

  20. Application and feasibility of coal fly ash and scrap tire fiber as wood wall insulation supplements in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Van de Lindt, J.W.; Carraro, J.A.H.; Heyliger, P.R.; Choi, C. [Colorado State University, Department of Civil and Environmental Engineering, Fort Collins, CO (United States)

    2008-08-15

    Each year, nearly 55% of the fly ash (FA) produced by coal burning power plants in the United States is disposed of in landfills and ash ponds, while the amount of recycled fiber from scrap tires that is beneficially used in end-user markets is virtually negligible. This paper presents the results of a study carried out to investigate whether it might be possible to increase the thermal efficiency of a light-frame residential structure through addition of a fly ash-scrap tire fiber composite to traditional fiberglass insulation in light-frame wood residential construction. This type of construction represents more than 80% of the building stock in North America. The results of this study suggest that the fly ash-scrap tire fiber composite provides a sustainable supplement to traditional insulation that not only increases the efficiency of traditional insulation but can also help significantly reduce the environmental issues associated with disposal of these waste products. (author)

  1. Application and feasibility of coal fly ash and scrap tire fiber as wood wall insulation supplements in residential buildings

    International Nuclear Information System (INIS)

    Van de Lindt, J.W.; Carraro, J.A.H.; Heyliger, P.R.; Choi, C.

    2008-01-01

    Each year, nearly 55% of the fly ash (FA) produced by coal burning power plants in the United States is disposed of in landfills and ash ponds, while the amount of recycled fiber from scrap tires that is beneficially used in end-user markets is virtually negligible. This paper presents the results of a study carried out to investigate whether it might be possible to increase the thermal efficiency of a light-frame residential structure through addition of a fly ash-scrap tire fiber composite to traditional fiberglass insulation in light-frame wood residential construction. This type of construction represents more than 80% of the building stock in North America. The results of this study suggest that the fly ash-scrap tire fiber composite provides a sustainable supplement to traditional insulation that not only increases the efficiency of traditional insulation but can also help significantly reduce the environmental issues associated with disposal of these waste products. (author)

  2. A methodology for energy performance classification of residential building stock of Hamirpur

    Directory of Open Access Journals (Sweden)

    Aniket Sharma

    2017-12-01

    Full Text Available In India, there are various codes, standards, guidelines and rating systems launched to make energy intensive and large sized buildings energy efficient whereas independent residential buildings are not covered even though they exist most in numbers of total housing stock. This paper presents a case study methodology for energy performance assessment of existing residential stock of Hamirpur that can be used to develop suitable energy efficiency regulations. The paper discusses the trend of residential development in Hamirpur followed by classification based on usage, condition, predominant material use, ownership size and number of rooms, source of lighting, assets available, number of storey and plot sizes using primary and secondary data. It results in identification of predominant materials used and other characteristics in each of urban and rural area. Further cradle to site embodied energy index of various dominant building materials and their market available alternative materials is calculated from secondary literature and by calculating transportation energy. One representative existing building is selected in each of urban and rural area and their energy performance is evaluated for material embodied energy and operational energy using simulation. Further alternatives are developed based on other dominant materials in each area and evaluated for change in embodied and operational energy. This paper identifies the energy performance of representative houses for both areas and in no way advocates the preference of one type over another. The paper demonstrates a methodology by which energy performance assessment of houses shall be done and also highlights further research.

  3. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  4. Load Disaggregation via Pattern Recognition: A Feasibility Study of a Novel Method in Residential Building

    Directory of Open Access Journals (Sweden)

    Younghoon Kwak

    2018-04-01

    Full Text Available In response to the need to improve energy-saving processes in older buildings, especially residential ones, this paper describes the potential of a novel method of disaggregating loads in light of the load patterns of household appliances determined in residential buildings. Experiments were designed to be applicable to general residential buildings and four types of commonly used appliances were selected to verify the method. The method assumes that loads are disaggregated and measured by a single primary meter. Following the metering of household appliances and an analysis of the usage patterns of each type, values of electric current were entered into a Hidden Markov Model (HMM to formulate predictions. Thereafter, the HMM repeatedly performed to output the predicted data close to the measured data, while errors between predicted and the measured data were evaluated to determine whether they met tolerance. When the method was examined for 4 days, matching rates in accordance with the load disaggregation outcomes of the household appliances (i.e., laptop, refrigerator, TV, and microwave were 0.994, 0.992, 0.982, and 0.988, respectively. The proposed method can provide insights into how and where within such buildings energy is consumed. As a result, effective and systematic energy saving measures can be derived even in buildings in which monitoring sensors and measurement equipment are not installed.

  5. Expert opinion on risks to the long-term viability of residential recycled water schemes: An Australian study.

    Science.gov (United States)

    West, Camilla; Kenway, Steven; Hassall, Maureen; Yuan, Zhiguo

    2017-09-01

    The water sector needs to make efficient and prudent investment decisions by carefully considering the long-term viability of water infrastructure projects. To support the assessment and planning of residential recycled water schemes in Australia, we have sought to clarify scheme objectives and to further define the array of critical risks that can impact the long-term viability of schemes. Building on historical information, we conducted a national survey which elicited responses from 88 Australian expert practitioners, of which 64% have over 10 years of industry experience and 42% have experience with more than five residential recycled water schemes. On the basis of expert opinion, residential recycled water schemes are considered to be highly relevant for diversifying and improving water supply security, reducing wastewater effluent discharge and pollutant load to waterways and contributing to sustainable urban development. At present however, the inability to demonstrate an incontestable business case is posing a significant risk to the long-term viability of residential recycled water schemes. Political, regulatory, organisational and financial factors were also rated as critical risks, in addition to community risk perception and fall in demand. The survey results shed further light on the regulatory environment of residential recycled water schemes, with regulatory participants rating the level and impact of risk factors higher than other survey participants in most cases. The research outcomes provide a comprehensive understanding of the critical risks to the long-term viability of residential recycled water schemes, thereby enabling the specification of targeted risk management measures at the assessment and planning stage of a scheme. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Thermal issues associated with the HVAC and lighting systems influences on the performance of the national ignition facility beam transport tubes

    International Nuclear Information System (INIS)

    Bernardin, J.D.; Parietti, L.; Martin, R.A.

    1998-01-01

    This report summarizes an investigation of the thermal issues related to the National Ignition Facility. In particular, the influences of the HVAC system and lighting fixtures on the operational performance of the laser guide beam tubes are reviewed and discussed. An analytical model of the oscillating HVAC air temperatures in the NIF switchyard and target bay will cause significant amounts of beam distortion. However, these negative effects can be drastically reduced by adding thermal insulation to the outside of the beam tubes. A computational fluid dynamics model and an analytical investigation found that the light-fixture to beam-tube separation distance must be on the order of 5.7 m (18.7 ft) to maintain acceptable beam operating performance in the current NIF design. By reducing the fluorescent light fixture power by 33% this separation distance can be reduced to 3.5 m (11.5 ft). If in addition, thermal insulation with a reflective aluminum foil covering is added to the outside of the beam tubes, the separation distance can be reduced further to 1.6m (5.2 ft). A 1.27 cm (0.5 in.) rigid foam insulation sheet with aluminum foil covering will provide adequate insulation for the beam tubes in the NIF switchyards and target bay. The material cost for this amount of insulation would be roughly $30,000

  7. Effects of socioeconomic factors on household appliance, lighting, and space cooling electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Aydinalp, M. [Itron Inc., Boston, MA (United States); Ismet Ugursal, V.; Fung, A.S. [Dalhousie University, Halifax (Canada). Dept. of Mechanical Engineering

    2003-07-01

    Two methods are currently used to model residential energy consumption at the national or regional level: the engineering method and the conditional demand analysis (CDA) method. One of the major difficulties associated with the use of engineering models is the inclusion of consumer behaviour and socioeconomic factors that have significant effects on the residential energy consumption. The CDA method can handle socioeconomic factors if they are included in the model formulation. However, the multicollinearity problem and the need for a very large amount of data make the use of CDA models very difficult. It is shown in this paper that the neural network (NN) method can be used to model the residential energy consumption with the inclusion of socioeconomic factors. The appliances, lighting, and cooling component of the NN based energy consumption model developed for the Canadian residential sector is presented here and the effects of some socioeconomic factors on the residential energy consumption are examined using the model. (author)

  8. Sustainability challenges of residential reinforced - concrete panel buildings

    Directory of Open Access Journals (Sweden)

    Markku J. Riihimäki

    2014-06-01

    Full Text Available Quite similar large-panel prefabrication technologies were used for residential buildings in East-Europe and some countries in Northern-Europe, e.g. Finland. Even if technologically similar, the fate of the building stocks is different in the two regions, with buildings functioning sustainably in Finland. Hence, one could adapt the maintenance and renovation experiences to the building stock in other countries, creating opportunities for communities and business. The paper presents technological, economical, and institutional/policy aspects in the two environments, and discusses them in the larger framework of European sustainability targets. For major renovation, as targeted in the paper, methods of change management should be applied, entailing thoughtful planning and sensitive implementation and above all, consultation/involvement of the people affected. If the presented interventions would be used in a systematic and planned way, improvements can be achieved for social sustainability targets like e.g. adaptability and visual comfort, while maintaining the safety and security. Finally, the limitations of the approach in light of the institutional setting and ownership structure are discussed, highlighting how different ownership models are favoring or hindering major retrofit interventions. The paper offers ways on strengthening the role of key stakeholders to support major renovation interventions on the panel building stock.

  9. RETHINKING RESIDENTIAL MOBILITY: AN INTERDISCIPLINARY INTERPRETATION

    Directory of Open Access Journals (Sweden)

    Roderick J. Lawrence

    2008-03-01

    Full Text Available Since the 1950s academics and professionals have proposed a number of disciplinary and sector based interpretations of why, when and where households move or choose to stay in the same housing unit at different periods of the life cycle and especially the family cycle. This article challenges studies that only analyse one set of factors. The article stems from a synthesis of 20 years of research by the author who  has an interdisciplinary training in the broad field of people-environment relations. First, it reviews some key concepts related to human ecology, including housing, culture, identity and cultivation. Then it will consider how these concepts can be applied to interpret residential mobility using an interdisciplinary approach. An empirical case study of residential mobility in Geneva, Switzerland is presented in order to show how this approach can help improve our understanding of the motives people have regarding the wish to stay in their residence or to move elsewhere.

  10. Micro-CHP systems for residential applications

    International Nuclear Information System (INIS)

    Paepe, Michel de; D'Herdt, Peter; Mertens, David

    2006-01-01

    Micro-CHP systems are now emerging on the market. In this paper, a thorough analysis is made of the operational parameters of 3 types of micro-CHP systems for residential use. Two types of houses (detached and terraced) are compared with a two storey apartment. For each building type, the energy demands for electricity and heat are dynamically determined. Using these load profiles, several CHP systems are designed for each building type. Data were obtained for two commercially available gas engines, two Stirling engines and a fuel cell. Using a dynamic simulation, including start up times, these five system types are compared to the separate energy system of a natural gas boiler and buying electricity from the grid. All CHP systems, if well sized, result in a reduction of primary energy use, though different technologies have very different impacts. Gas engines seem to have the best performance. The economic analysis shows that fuel cells are still too expensive and that even the gas engines only have a small internal rate of return (<5%), and this only occurs in favourable economic circumstances. It can, therefore, be concluded that although the different technologies are technically mature, installation costs should at least be reduced by 50% before CHP systems become interesting for residential use. Condensing gas boilers, now very popular in new homes, prove to be economically more interesting and also have a modest effect on primary energy consumption

  11. Economic aspects of possible residential heating conservation

    Energy Technology Data Exchange (ETDEWEB)

    Hopkowicz, M.; Szul, A. [Technical Univ., Cracow (Poland)

    1995-12-31

    The paper presents methods of evaluation of energy and economy related effects of different actions aimed at conservation in residential buildings. It identifies also the method of selecting the most effective way of distribution funds assigned to weatherization as well as necessary improvements to be implemented within the heating node and the internal heating system of the building. The analysis of data gathered for four 11-stories high residential buildings of {open_quotes}Zeran{close_quotes} type being subject of the Conservation Demonstrative Project, included a differentiated scope of weatherization efforts and various actions aimed at system upgrading. Basing upon the discussion of the split of heat losses in a building as well as the established energy savings for numerous options of upgrading works, the main problem has been defined. It consists in optimal distribution of financial means for the discussed measures if the total amount of funds assigned for modifications is defined. The method based upon the principle of relative increments has been suggested. The economical and energy specifications of the building and its components, required for this method have also been elaborated. The application of this method allowed to define the suggested optimal scope of actions within the entire fund assigned for the comprehensive weatherization.

  12. Canadian energy standards : residential energy code requirements

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, K. [SAR Engineering Ltd., Burnaby, BC (Canada)

    2006-09-15

    A survey of residential energy code requirements was discussed. New housing is approximately 13 per cent more efficient than housing built 15 years ago, and more stringent energy efficiency requirements in building codes have contributed to decreased energy use and greenhouse gas (GHG) emissions. However, a survey of residential energy codes across Canada has determined that explicit demands for energy efficiency are currently only present in British Columbia (BC), Manitoba, Ontario and Quebec. The survey evaluated more than 4300 single-detached homes built between 2000 and 2005 using data from the EnerGuide for Houses (EGH) database. House area, volume, airtightness and construction characteristics were reviewed to create archetypes for 8 geographic areas. The survey indicated that in Quebec and the Maritimes, 90 per cent of houses comply with ventilation system requirements of the National Building Code, while compliance in the rest of Canada is much lower. Heat recovery ventilation use is predominant in the Atlantic provinces. Direct-vent or condensing furnaces constitute the majority of installed systems in provinces where natural gas is the primary space heating fuel. Details of Insulation levels for walls, double-glazed windows, and building code insulation standards were also reviewed. It was concluded that if R-2000 levels of energy efficiency were applied, total average energy consumption would be reduced by 36 per cent in Canada. 2 tabs.

  13. Family Structure, Residential Mobility, and Environmental Inequality

    Science.gov (United States)

    Downey, Liam; Crowder, Kyle; Kemp, Robert J.

    2016-01-01

    This study combines micro-level data on families with children from the Panel Study of Income Dynamics with neighborhood-level industrial hazard data from the Environmental Protection Agency and neighborhood-level U.S. census data to examine both the association between family structure and residential proximity to neighborhood pollution and the micro-level, residential mobility processes that contribute to differential pollution proximity across family types. Results indicate the existence of significant family structure differences in household proximity to industrial pollution in U.S. metropolitan areas between 1990 and 1999, with single-mother and single-father families experiencing neighborhood pollution levels that are on average 46% and 26% greater, respectively, than those experienced by two-parent families. Moreover, the pollution gap between single-mother and two-parent families persists with controls for household and neighborhood socioeconomic, sociodemographic, and race/ethnic characteristics. Examination of underlying migration patterns reveals that single-mother, single-father, and two-parent families are equally likely to move in response to pollution. However, mobile single-parent families move into neighborhoods with significantly higher pollution levels than do mobile two-parent families. Thus, family structure differences in pollution proximity are maintained more by these destination neighborhood differences than by family structure variations in the likelihood of moving out of polluted neighborhoods. PMID:28348440

  14. Residential proximinity, perceived and acceptable risk

    International Nuclear Information System (INIS)

    Rogers, G.O.

    1984-01-01

    This paper focuses on the relationship between the life experiences associated with residential proximity, and the perception and acceptability of the risks associated with generating electricity in nuclear power plants. Perceived risk is operationally defined in terms of estimated likelihood of occurrence, while acceptability of nuclear power is defined in terms of people's favorable or unfavorable opinions regarding nuclear power plants. In the context of a simple social-structural model of perceived and acceptable risk, four potential explanations for enhanced acceptability among those residentially proximate with nuclear facilities are examined: residents, through the experience of living with hazard, are reinforced toward assigning lower probabilities to the potential risks associated with nuclear facilities; the cognitive dissonance created by the acceptance of the risks associated with nuclear power is decreased by reducing perceived risk; nuclear neighbors are predisposed toward, educated about, and/or economically dependent upon nuclear power hence the more favorable attitudes toward it; nearby residents are systematically more altruistic--other oriented--than the general population and thus more willing to bear the risks associated with nuclear power

  15. Solar Energy Systems for Ohioan Residential Homeowners

    Science.gov (United States)

    Luckett, Rickey D.

    Dwindling nonrenewable energy resources and rising energy costs have forced the United States to develop alternative renewable energy sources. The United States' solar energy industry has seen an upsurge in recent years, and photovoltaic holds considerable promise as a renewable energy technology. The purpose of this case study was to explore homeowner's awareness of the benefits of solar energy. Disruptive-innovation theory was used to explore marketing strategies for conveying information to homeowners about access to new solar energy products and services. Twenty residential homeowners were interviewed face-to-face to explore (a) perceived benefits of solar energy in their county in Ohio, and (b) perceptions on the rationale behind the marketing strategy of solar energy systems sold for residential use. The study findings used inductive analyses and coding interpretation to explore the participants' responses that revealed 3 themes: the existence of environmental benefits for using solar energy systems, the expensive cost of equipment associated with government incentives, and the lack of marketing information that is available for consumer use. The implications for positive social change include the potential to enable corporate leaders, small business owners, and entrepreneurs to develop marketing strategies for renewable energy systems. These strategies may promote use of solar energy systems as a clean, renewable, and affordable alternative electricity energy source for the 21st century.

  16. Residential carbon monoxide poisoning from motor vehicles.

    Science.gov (United States)

    Hampson, Neil B

    2011-01-01

    Although morbidity and mortality from accidental carbon monoxide (CO) poisoning are high in the United States, identification of common but poorly recognized sources should help prevention efforts. The study aimed to describe CO poisoning of home occupants due to a vehicle left running in an attached garage. News stories reporting incidents of US CO poisoning were collected daily from March 2007 to September 2009 via a news.Google.com search and data extracted. Patients were individuals reported in the media to have been poisoned with CO in their home by a vehicle running in the attached garage. Main outcome measures were frequency of occurrence, geographic distribution, patient demographics, and mortality. Of 837 CO poisoning incidents reported in US news media over 2 and a half years, 59 (8%) were the result of a vehicle left running in the garage. The elderly were disproportionately affected, with incidents most common in states with larger elderly populations and 29% of cases with age specified occurring in individuals older than 80 years. Among those older than 80 years, 15 of 17 were found dead at the scene. Residential CO poisoning from a vehicle running in the garage is common, disproportionately affects the elderly, has a high mortality rate, and should be preventable with a residential CO alarm. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Survey of residential magnetic field sources

    International Nuclear Information System (INIS)

    Zaffanella, L.E.

    1992-09-01

    A nationwide survey of 1000 residences is underway to determine the sources and characteristics of magnetic fields in the home. This report describes the goals, statistical sampling methods, measurement protocols, and experiences in measuring the first 707 residences of the survey. Some preliminary analysis of the data is also included. Investigators designed a sampling method to randomly select the participating utilities as well as the residential customers for the study. As a first step in the project, 18 utility employee residences were chosen to validate a relatively simple measurement protocol against the results of a more complete and intrusive method. Using the less intrusive measurement protocol, researchers worked closely with representatives from EPRI member utilities to enter customer residences and measure the magnetic fields found there. Magnetic field data were collected in different locations inside and around the residences. Twenty-four-hour recorders were left in the homes overnight. Tests showed that the simplified measurement protocol is adequate for achieving the goals of the study. Methods were developed for analyzing the field caused by a residence's ground current, the lateral field profiles of field lines, and the field measured around the periphery of the residences. Methods of residential source detection were developed that allow identification of sources such as ground connections at an electrical subpanel, two-wire multiple-way switches, and underground or overhead net currents exiting the periphery of a residence

  18. The effects of implant-macro design on stress quantity and distribution around three types of fixtures by photo-elastic analysis

    Directory of Open Access Journals (Sweden)

    Shams Ak

    2011-04-01

    Full Text Available "nBackground and Aims: Considering the great incidence of implant failures due to high stresses around implant and at bone-implant interfaces, the aim of this study was to compare the effects of three different implant-macro designs on the quantity and distribution pattern of stresses around implants."nMaterials and Methods: In this experimental in vitro study, three types of implants including Biohorizon (4×10.5 mm, Iler (4×10 mm, and Swiss Plus (4.1×10 mm were studied by applying photo-elastic method. The implants were placed within photo-elastic models with dimensions of 50×50×10 mm. Then through open tray impressed method, crowns for each implant were constructed and cemented. Vertical and oblique loads of 100 N and 150 N were applied on the cemented crowns within polariscope machine. Then the photographs were evaluated using Isochromatic Fringe Characteristics table."nResults: Under vertical loads of 100 N and 150 N, the values for Biohorizon, Iler, Swiss Plus fixtures at the cervical region were (2.35, 3.60 N, (2.50, 3.10 N, and (1.39, 2.35 N, respectively; and in apical region the values were (1.63, 2.35 N, (1.82, 2.35 N, and (2.50, 3.10 N. Under oblique loads, the measures at the cervical region were (4.00, 5.00 N, (1.82, 5.00 N, and (5.20, 6.00 N; and in apical region were "n(1.39, 2.00 N, (4.00, 2.35 N, and (2.35, 3.00 N, respectively for mentioned implants."nConclusion: Under vertical loads, the lowest cervical stresses were observed in Swiss Plus fixture and the lowest apical stress values were recorded for Biohorizon fixture. Under oblique loads, the lowest cervical stresses were found in Iler implant and lowest apical stresses were recorded for Bohorizon.

  19. "Tangible Lights"

    DEFF Research Database (Denmark)

    Sørensen, Tor; Merritt, Timothy; Andersen, Oskar

    2015-01-01

    While there has been much focus on tangible lighting interfaces embedded in physical objects and smartphones as remote control, there has not been sufficient attention on how the expressivity of bodily movement can be used when designing interactions with light. Therefore, we investigate...... interaction with lighting technology beyond the smartphone and physical controllers. We examine the usefulness of the in-air gestural interaction style for lighting control. We bring forward "Tangible Lights", which serves as a novel interface for in-air interaction with lighting, drawing on existing...

  20. Examination of Negative Peer Contagion in a Residential Care Setting

    Science.gov (United States)

    Huefner, Jonathan C.; Ringle, Jay L.

    2012-01-01

    There has been ongoing concern about the negative impact of residential treatment on youth in care. Research examining the impact of negative peer influence in juvenile justice, education, and residential care settings is reviewed. A study was conducted to examine the impact of negative peer contagion on the level of problem behavior in a…

  1. Family-centred residential care : the new reality?

    NARCIS (Netherlands)

    Geurts, Esther M. W.; Boddy, Janet; Noom, Marc J.; Knorth, Erik J.

    This paper considers therapeutic approaches to residential care with specific attention to the question of family involvement. It builds on a body of literature indicating the potential of residential care as a positive intervention for young people, and examines the contention that even when family

  2. Episodic and Semantic Memories of a Residential Environmental Education Program

    Science.gov (United States)

    Knapp, Doug; Benton, Gregory M.

    2006-01-01

    This study used a phenomenological approach to investigate the recollections of participants of an environmental education (EE) residential program. Ten students who participated in a residential EE program in the fall of 2001 were interviewed in the fall of 2002. Three major themes relating to the participants' long-term memory of the residential…

  3. Residential Preferences: What's Terrorism Got to Do with It?

    Science.gov (United States)

    Kay, David; Geisler, Charles; Bills, Nelson

    2010-01-01

    Security has long been recognized as an element in residential preference and its relative importance has risen with fear of extremist attacks on U.S. cities. Using polling data from 2004, this research investigates whether the security breaches of 9/11 in New York City influenced residential preferences in New York State. Our results confirm that…

  4. Residential land values and their determinants in high density ...

    African Journals Online (AJOL)

    The study identified that residential segregation exists in Nigerian cities and the study area. Among urbanization and residential land use problems identified by the study are poor level of social and technical infrastructure, poor land and city management system capacity, paucity of planning laws, funding, poor institutional ...

  5. Potential energy savings by using direct current for residential applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2017-01-01

    improvement in the power converter units. However, for residential applications, the efficiency is not always improved. A grid connected residential microgrid, with renewable energy sources (RES), energy storage systems (ESS) and local loads, is presented in this work. The microgrid has been modelled...

  6. 2011 Residential Energy Efficiency Technical Update Meeting Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-11-01

    This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.

  7. Contestation in the Use of Residential space: House Typologies and ...

    African Journals Online (AJOL)

    The need to accommodate the populace creates competition for space; the outcome of this competition has produced differently zoned areas such as residential areas, shopping centres, parks and office towers. Bulawayo's residential areas are dominated by one-household units or detached one-storey houses in the ...

  8. Exploring the Relationship between Conduct Disorder and Residential Treatment Outcomes

    Science.gov (United States)

    Shabat, Julia Cathcart; Lyons, John S.; Martinovich, Zoran

    2008-01-01

    We examined the differential outcomes in residential treatment for youths with conduct disorder (CD)--with special attention paid to interactions with age and gender--in a sample of children and adolescents in 50 residential treatment centers and group homes across Illinois. Multi-disciplinary teams rated youths ages 6-20 (N = 457) on measures of…

  9. Effect of Organizational Climate on Youth Outcomes in Residential Treatment

    Science.gov (United States)

    Jordan, Neil; Leon, Scott C.; Epstein, Richard A.; Durkin, Elizabeth; Helgerson, Jena; Lakin-Starr, Brittany L.

    2009-01-01

    This study examined the association between organizational climate and changes in internalizing and externalizing behavior for youth in residential treatment centers (RTCs). The sample included 407 youth and 349 front-line residential treatment staff from 17 RTCs in Illinois. Youth behavior was measured using the Child Functional Assessment Rating…

  10. Residential Mobility, Inhibitory Control, and Academic Achievement in Preschool

    Science.gov (United States)

    Schmitt, Sara A.; Finders, Jennifer K.; McClelland, Megan M.

    2015-01-01

    Research Findings: The present study investigated the direct effects of residential mobility on children's inhibitory control and academic achievement during the preschool year. It also explored fall inhibitory control and academic skills as mediators linking residential mobility and spring achievement. Participants included 359 preschool children…

  11. Radical programmes for developing the EU residential building sector

    NARCIS (Netherlands)

    Oostra, Mieke; Huovinen, Pekka

    2016-01-01

    The economic recession has hit especially hard the residential building sector in the EU region, e.g., the number of the housing completions has decreased -49% and the total residential output has been squeezed down by -24% between 2007 and 2014 (Euroconstruct, 2015). In turn, the aim of our paper

  12. Engineering economic assessment of residential wood heating in NY

    Science.gov (United States)

    We provide insight into the recent resurgence in residential wood heating in New York by: (i) examining the lifetime costs of outdoor wood hydronic heaters (OWHHs) and other whole-house residential wood heat devices,(ii) comparing these lifetime costs with those of competing tech...

  13. Demand of elderly people for residential care: an exploratory study

    NARCIS (Netherlands)

    van Bilsen, P.; Hamers, J.; Groot, W.; Spreeuwenberg, C.

    2006-01-01

    Background: Because of the rapid aging population, the demand for residential care exceeds availability. This paper presents the results of a study that focuses on the demand of elderly people for residential care and determinants (elderly people's personal characteristics, needs and resources) that

  14. 77 FR 9700 - Large Residential Washers From Korea and Mexico

    Science.gov (United States)

    2012-02-17

    ...)] Large Residential Washers From Korea and Mexico Determinations On the basis of the record \\1\\ developed... reasonable indication that an industry is materially injured by reason of imports from Mexico of large... imports of large residential washers from Mexico. Accordingly, effective December 30, 2011, the Commission...

  15. 77 FR 51569 - Large Residential Washers From Korea and Mexico

    Science.gov (United States)

    2012-08-24

    ...)] Large Residential Washers From Korea and Mexico Scheduling of the final phase of countervailing duty and... and Mexico of large residential washers, provided for in subheading 8450.20.00 of the Harmonized... and Mexico are being sold in the United States at less than fair value within the meaning of section...

  16. 78 FR 10636 - Large Residential Washers From Korea and Mexico

    Science.gov (United States)

    2013-02-14

    ... Residential Washers From Korea and Mexico Determinations On the basis of the record \\1\\ developed in the... determines that an industry in the United States is materially injured by reason of imports from Mexico of... of large residential washers from Korea and Mexico were sold at LTFV within the meaning of 733(b) of...

  17. Energy efficiency in U.S. residential rental housing: Adoption rates and impact on rent

    International Nuclear Information System (INIS)

    Im, Jongho; Seo, Youngme; Cetin, Kristen S.; Singh, Jasmeet

    2017-01-01

    Highlights: •Rental units listings collected and analyzed for 10 U.S. cities. •Energy efficient features included in 5.3–21.6% of rental units in each city. •The most common efficient features are lighting and appliance upgrades. •Propensity score matching and conditional mean comparison methods used. •Generally, energy efficient features increases the units’ rent, overall from 6% to 14%. -- Abstract: For 118 million residential housing units in the U.S., there is currently a gap between the potential energy savings that can be achieved through the use of existing energy efficiency technologies, and the actual level of energy savings realized, particularly for the 37% of housing units that are considered residential rental properties. Additional quantifiable benefits are needed beyond energy savings to help further motivate residential property owners to invest in energy efficiency upgrades. This research focuses on assessing the adoption of energy efficient upgrades in U.S. residential housing and the impact on rental prices. Ten U.S. cities are chosen for analysis; these cities vary in size across multiple climate zones, and represent a diverse set of housing market conditions. Data was collected for over 159,000 rental property listings, their characteristics, and their energy efficiency measures listed in rental housing postings across each city. Following an extensive data quality control process, over thirty different types energy efficient features were identified. The level of adoption was determined for each city, ranging from 5.3% to 21.6%. Efficient lighting and appliances were among the most common, with many features doubling as energy efficient and other desirable aesthetic or comfort improvements. Then using propensity score matching and conditional mean comparison methods, the relative impact on rent charged in each city was calculated, which ranged from a 6% to 14.1% increase in rent for properties with energy efficient features

  18. Index decomposition analysis of residential energy consumption in China: 2002–2010

    International Nuclear Information System (INIS)

    Nie, Hongguang; Kemp, René

    2014-01-01

    Highlights: • We examine residential energy use in China and predict household electricity use. • We decompose the dramatic increase of residential energy use in China. • Driving factors consist of population, floor space, energy mix and appliances. • Floor space per capita effect becomes increasingly important over time. • Electricity use from appliances will continue to rise despite a saturation. - Abstract: Residential energy consumption in China increased dramatically over the period of 2002–2010. In this paper, we undertake a decomposition analysis of changes in energy use by Chinese households for five energy-using activities: space heating/cooling, cooking, lighting and electric appliances. We investigate to what extent changes in energy use are due to changes from appliances and to change in floor space, population and energy mix. Our decomposition analysis is based on the logarithmic mean Divisia index technique using data from the China statistical yearbook and China energy statistical yearbook in the period of 2002–2010. According to our results, the increase in energy-using appliances is the biggest contributor to the increase of residential energy consumption during 2002–2010 but the effect declines over time, due to energy efficiency improvements in those appliances. The second most important contributor is floor space per capita, which increased with 28%. Of the four factors, population is the most stable factor and energy mix is the least important factor. We predicted electricity use, with the help of regression-based predictions for ownership of appliances and the energy efficiency of appliances. We found that electricity use will continue to rise despite a gradual saturation of demand

  19. Residential heat pumps in the future Danish energy system

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    for politically agreed targets which include: at least 50% of electricity consumption from wind power starting from 2020, fossil fuel free heat and power sector from 2035 and 100% renewable energy system starting from 2050. Residential heat pumps supply around 25% of total residential heating demand after 2035......Denmark is striving towards 100% renewable energy system in 2050. Residential heat pumps are expected to be a part of that system.We propose two novel approaches to improve the representation of residential heat pumps: Coefficients of performance (COPs) are modelled as dependent on air and ground...... temperature while installation of ground-source heat pumps is constrained by available ground area. In this study, TIMES-DK model is utilised to test the effects of improved modelling of residential heat pumps on the Danish energy system until 2050.The analysis of the Danish energy system was done...

  20. Residential damage in an area of underground coal mining

    International Nuclear Information System (INIS)

    Padgett, M.F.

    1988-01-01

    In order to estimate the potential for future subsidence-related residential damage, a statistical analysis of past residential damage in the Boulder-Weld, Colorado, coal field was performed. The objectives of this study were to assess the difference in damage severity and frequency between undermined and non-undermined areas, and to determine, where applicable, which mining factors significantly influence the severity and frequency of residential damage. The results of this study suggest that undermined homes have almost three times the risk of having some type of structural damage than do non-undermined homes. The study also indicated that both geologic factors, such as the ratio of sandstone/claystone in the overburden, and mining factors, such as the mining feature (room, pillar, entry, etc.), can significantly affect the severity of overlying residential damage. However, the results of this study are dependent on local conditions and should not be applied elsewhere unless the geologic, mining, and residential conditions are similar

  1. Analysis of a Residential Building Energy Consumption Demand Model

    Directory of Open Access Journals (Sweden)

    Meng Liu

    2011-03-01

    Full Text Available In order to estimate the energy consumption demand of residential buildings, this paper first discusses the status and shortcomings of current domestic energy consumption models. Then it proposes and develops a residential building energy consumption demand model based on a back propagation (BP neural network model. After that, taking residential buildings in Chongqing (P.R. China as an example, 16 energy consumption indicators are introduced as characteristics of the residential buildings in Chongqing. The index system of the BP neutral network prediction model is established and the multi-factorial BP neural network prediction model of Chongqing residential building energy consumption is developed using the Cshap language, based on the SQL server 2005 platform. The results obtained by applying the model in Chongqing are in good agreement with actual ones. In addition, the model provides corresponding approximate data by taking into account the potential energy structure adjustments and relevant energy policy regulations.

  2. Light Robotics

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin

    Light Robotics - Structure-Mediated Nanobiophotonics covers the latest means of sculpting of both light and matter for achieving bioprobing and manipulation at the smallest scales. The synergy between photonics, nanotechnology and biotechnology spans the rapidly growing field of nanobiophotonics...

  3. Surgical lighting

    NARCIS (Netherlands)

    Knulst, A.J.

    2017-01-01

    The surgical light is an important tool for surgeons to create and maintain good visibility on the surgical task. Chapter 1 gives background to the field of (surgical) lighting and related terminology. Although the surgical light has been developed strongly since its introduction a long time ago,

  4. Twisted light

    CSIR Research Space (South Africa)

    Forbes, A

    2010-12-01

    Full Text Available Research at the Mathematical Optics Group uses "twisted" light to study new quatum-based information security systems. In order to understand the structure of "twisted" light, it is useful to start with an ordinary light beam with zero twist, namely...

  5. [Childhood Experiences of Adolescents in Boarding Schools. A Comparison with Adolescents in Residential Care and with the General Population].

    Science.gov (United States)

    Rau, Thea; Ohlert, Jeannine; Fegert, Jörg M; Andresen, Sabine; Pohling, Andrea; Allroggen, Marc

    2018-01-01

    Childhood Experiences of Adolescents in Boarding Schools. A Comparison with Adolescents in Residential Care and with the General Population Various studies indicate that students in boarding schools experience a lot of violence during their accommodation. However, it is not proved whether adolescents in boarding schools are also a burdensome group regarding early childhood experiences such as neglect and abuse. The aim of the study was to find out more about the experiences of adolescents in boarding schools and to determine whether there are differences between adolescents in residential care and between the general population. Furthermore, it should be examined whether boys and girls differ in their experiences. In the study, adolescents of boarding schools and of residential care all over Germany, starting at the age of 15 (n = 322), were asked regarding physical and emotional neglect/abuse, light/severe parent violence, negative/positive educational behavior of the parents. The results show that students in boarding schools were less likely to be affected by childhood maltreatment and more likely to have experienced positive parental behavior compared to children in residential care. Compared to the general population, students in boarding schools were more often and more severely affected by parental violence. Moreover, girls had experienced parental violence more often than boys. The results indicate that in boarding schools there is a need for support offers for adolescents with a history of violent experiences and that the risk group should be identified directly at the admission to the school.

  6. Residential mobility and migration of the separated

    Directory of Open Access Journals (Sweden)

    Maarten van Ham

    2007-12-01

    Full Text Available Separation is known to have a disruptive effect on the housing careers of those involved, mainly because a decrease in resources causes (temporary downward moves on the housing ladder. Little is known about the geographies of the residential mobility behaviour of the separated. Applying a hazard analysis to retrospective life-course data for the Netherlands, we investigate three hypotheses: individuals who experienced separation move more often than do steady singles and people in intact couple relationships, they are less likely to move over long distances, and they move more often to cities than people in intact couple relationships. The results show that separation leads to an increase in mobility, to moves over short distance for men with children, and to a prevalence of the city as a destination of moves.

  7. Particulate emissions from residential wood combustion

    DEFF Research Database (Denmark)

    Luis Teles de Carvalho, Ricardo; Jensen, Ole Michael; Tarelho, Luis A. C.

    Residential wood combustion (RWC) in fireplaces and conventional appliances is the main contributor to fine particulate matter (PM2.5) emissions in Denmark and Portugal representing more than 30% of the total emissions [1;2]. Such estimations are uncertain concerning the wood consumption...... and official emission factors, not taking into account actual burning conditions in dwellings [3]. There is limited knowledge on the real-life performance and spatial distribution of existing appliance types. Few studies have been targeting to understand the influence of fuel operation habits on PM2...... the available estimations for Denmark and Portugal, suggesting a methodology to increase the accuracy of activity data and emission factors. This work is based on new studies carried out to quantify the PM2.5 emissions in daily life through field experiments in Danish dwellings and by considering typical...

  8. Competitive solar heating systems for residential buildings

    DEFF Research Database (Denmark)

    Furbo, Simon; Thür, Alexander; Fiedler, Frank

    2005-01-01

    The paper describes the ongoing research project “Competitive solar heating systems for residential buildings”. The aim of the project is to develop competitive solar combisystems which are attractive to buyers. The solar combisystems must be attractive compared to traditional energy systems, both....... In Denmark and Norway the focus is on solar heating/natural gas systems, and in Sweden and Latvia the focus is on solar heating/pellet systems. Additionally, Lund Institute of Technology and University of Oslo are studying solar collectors of various types being integrated into the roof and facade......, are the universities: Technical University of Denmark, Dalarna University, University of Oslo, Riga Technical University and Lund Institute of Technology, as well as the companies: Metro Therm A/S (Denmark), Velux A/S (Denmark), Solentek AB (Sweden) and SolarNor (Norway). The project consists of a number of Ph...

  9. Quebec residential electricity demand: a microeconometric approach

    International Nuclear Information System (INIS)

    Bernard, J.T.; Bolduc, D.; Belanger, D.

    1996-01-01

    An economic analysis of Quebec residential electricity demand was studied by micro-simulation models. These structural models describe all components which lead to decisions upon durable holdings and electric appliance usage. The demand for space and water heating systems was evaluated. Recent price change in favour of energy sources other than electricity were taken into account. Price and income elasticity ratios were found to be low, as expected when estimating short term use. The role played by socio-economic variables on the choice of space-water heating systems and electricity use was also examined. Recent conversions have indicated a trend toward preference by households in favour of natural gas or oil over electricity. 18 refs., 5 tabs., 1 fig

  10. Adaptive Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin; Kongshaug, Jesper

    2015-01-01

    the investigations of lighting scenarios carried out in two test installations: White Cube and White Box. The test installations are discussed as large-scale experiential instruments. In these test installations we examine what could potentially occur when light using LED technology is integrated and distributed......Adaptive Lighting Adaptive lighting is based on a partial automation of the possibilities to adjust the colour tone and brightness levels of light in order to adapt to people’s needs and desires. IT support is key to the technical developments that afford adaptive control systems. The possibilities...... differently into an architectural body. We also examine what might occur when light is dynamic and able to change colour, intensity and direction, and when it is adaptive and can be brought into interaction with its surroundings. In short, what happens to an architectural space when artificial lighting ceases...

  11. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  12. Hypospadias and residential proximity to pesticide applications.

    Science.gov (United States)

    Carmichael, Suzan L; Yang, Wei; Roberts, Eric M; Kegley, Susan E; Wolff, Craig; Guo, Liang; Lammer, Edward J; English, Paul; Shaw, Gary M

    2013-11-01

    Experimental evidence suggests pesticides may be associated with hypospadias. Examine the association of hypospadias with residential proximity to commercial agricultural pesticide applications. The study population included male infants born from 1991 to 2004 to mothers residing in 8 California counties. Cases (n = 690) were ascertained by the California Birth Defects Monitoring Program; controls were selected randomly from the birth population (n = 2195). We determined early pregnancy exposure to pesticide applications within a 500-m radius of mother's residential address, using detailed data on applications and land use. Associations with exposures to physicochemical groups of pesticides and specific chemicals were assessed using logistic regression adjusted for maternal race or ethnicity and age and infant birth year. Forty-one percent of cases and controls were classified as exposed to 57 chemical groups and 292 chemicals. Despite >500 statistical comparisons, there were few elevated odds ratios with confidence intervals that excluded 1 for chemical groups or specific chemicals. Those that did were for monochlorophenoxy acid or ester herbicides; the insecticides aldicarb, dimethoate, phorate, and petroleum oils; and adjuvant polyoxyethylene sorbitol among all cases; 2,6-dinitroaniline herbicides, the herbicide oxyfluorfen, and the fungicide copper sulfate among mild cases; and chloroacetanilide herbicides, polyalkyloxy compounds used as adjuvants, the insecticides aldicarb and acephate, and the adjuvant nonyl-phenoxy-poly(ethylene oxy)ethanol among moderate and severe cases. Odds ratios ranged from 1.9 to 2.9. Most pesticides were not associated with elevated hypospadias risk. For the few that were associated, results should be interpreted with caution until replicated in other study populations.

  13. Evaluation of Daylight Intensity for Sustainbility in Residential Buildings in Cantonment Cottages Multan

    Directory of Open Access Journals (Sweden)

    SUMRA YOUSUF

    2017-07-01

    Full Text Available Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. Inorderto evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers. After investigation, it has been found that daylight factor is much higher than the standard values

  14. Factors contributing to the fluctuations in residential construction in Iran

    Directory of Open Access Journals (Sweden)

    Hassan Gholipour Fereidouni

    2011-12-01

    Full Text Available Residential construction is one of the most important pillars of Iran’s economy. Although this sector had an increasing trend over the past two decades, however, the growth rate of residential construction was very volatile. The purpose of this paper is to empirically investigate those factors contributing to this fluctuation over the 1991:Q2-2008:Q4. By applying cointegration approach, the empirical results show that housing prices, construction costs, GDP and gold prices are important factors to explain swings in residential construction in Iran.

  15. Fire Situations and Prevention Measures of residential building

    Directory of Open Access Journals (Sweden)

    Zhou Baixia

    2017-01-01

    Full Text Available The proportion of residential building is the largest in all buildings. With the development of urbanization, residential building fires are at high momentum. The paper lists the residential building fires and the number of casualties’ proportion to total fires from 2011 to 2014, analyzing the high incidence causes of the fires and casualties and putting forward suggestions and countermeasures including carrying out fire safety education to improve the fire safety awareness of residents, fulfilling responsibility to enhancing fire safety management capabilities, perfecting fire apparatus to develop fire safety environment and enhancing public awareness of fire safety, equipping evacuation equipments to promote response ability to deal with disasters etc.

  16. Nordic Lighting?

    DEFF Research Database (Denmark)

    Munch, Anders V.

    2018-01-01

    The Danish designer Poul Henningsen wrote very elaborated theories of interior lighting from the mid-1920s on. He fought against the cold and reduced light quality of electric bulbs and tried to tame and cultivate this technology by design. He wanted a more rich light for domestic purpose...... worthwhile discussing than other design categories to interpret, whether experience of nature and climatic conditions play a role in Scandinavian Design, as repeatedly stated. This discussion contributes both to understanding of interior lighting and the historiographical critique of Scandinavian Design...... and shaped it through lamp design, colour reflections and differentiated use of several lamps in the room to make a more dim lighting, but with greater variation and softer contrasts. It was a ‘culture’ of lighting, he promoted, but he didn’t saw it as linked to the Nordic countries. His sensibility...

  17. Adaptive Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin; Kongshaug, Jesper

    2015-01-01

    Adaptive Lighting Adaptive lighting is based on a partial automation of the possibilities to adjust the colour tone and brightness levels of light in order to adapt to people’s needs and desires. IT support is key to the technical developments that afford adaptive control systems. The possibilities...... offered by adaptive lighting control are created by the ways that the system components, the network and data flow can be coordinated through software so that the dynamic variations are controlled in ways that meaningfully adapt according to people’s situations and design intentions. This book discusses...... differently into an architectural body. We also examine what might occur when light is dynamic and able to change colour, intensity and direction, and when it is adaptive and can be brought into interaction with its surroundings. In short, what happens to an architectural space when artificial lighting ceases...

  18. WOW: light print, light propel, light point

    Science.gov (United States)

    Glückstad, Jesper; Bañas, Andrew; Aabo, Thomas; Palima, Darwin

    2012-10-01

    We are presenting so-called Wave-guided Optical Waveguides (WOWs) fabricated by two-photon polymerization and capable of being optically manipulated into any arbitrary orientation. By integrating optical waveguides into the structures we have created freestanding waveguides which can be positioned anywhere in a sample at any orientation using real-time 3D optical micromanipulation with six degrees of freedom. One of the key aspects of our demonstrated WOWs is the change in direction of in-coupled light and the marked increase in numerical aperture of the out-coupled light. Hence, each light propelled WOW can tap from a relatively broad incident beam and generate a much more tightly confined light at its tip. The presentation contains both numerical simulations related to the propagation of light through a WOW and preliminary experimental demonstrations on our BioPhotonics Workstation. In a broader context, this research shows that optically trapped micro-fabricated structures can potentially help bridge the diffraction barrier. This structure-mediated paradigm may be carried forward to open new possibilities for exploiting beams from far-field optics down to the sub-wavelength domain.

  19. Adaptive Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Kongshaug, Jesper; Søndergaard, Karin

    2015-01-01

    offered by adaptive lighting control are created by the ways that the system components, the network and data flow can be coordinated through software so that the dynamic variations are controlled in ways that meaningfully adapt according to people’s situations and design intentions. This book discusses...... to be static, and no longer acts as a kind of spatial constancy maintaining stability and order? Moreover, what new potentials open in lighting design? This book is one of four books that is published in connection with the research project entitled LED Lighting; Interdisciplinary LED Lighting Research...

  20. Constructive heuristics for the residential waste collection problem

    CSIR Research Space (South Africa)

    Willemse, EJ

    2011-09-01

    Full Text Available The Residential Waste Collection Problem (RWCP) is a realistic extension of the classical Capacitated Arc Routing Problem (CARP), with application in municipal waste collection. Surprisingly, the problem with its extensions have not been solved...

  1. Residential Energy Efficiency Research Planning Meeting Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2012-02-01

    This report summarizes key findings and outcomes from the U.S. Department of Energy's Building America Residential Energy Efficiency Research Planning meeting, held on October 28-29, 2011, in Washington, D.C.

  2. Use of Electronic Health Records in Residential Care Communities

    Science.gov (United States)

    ... The 2010 NSRCF used a stratified two-stage probability sampling design. The first stage was the selection ... 3,605 residential care communities were sampled with probability proportional to size. Interviews were completed with 2, ...

  3. Spatial Variations of Values of Residential Land Use in Lagos ...

    African Journals Online (AJOL)

    Nekky Umera

    There exist literature on urban land use values and environmental planning. They are .... intra-urban location bid-rent model and the concept of residential land value ... emerges an ordinary pattern of land use, spatially organized to perform.

  4. Measuring Group Care Worker Interventions in Residential Youth Care

    NARCIS (Netherlands)

    Bastiaanssen, I.L.W.; Kroes, G.; Nijhof, K.S.; Delsing, M.J.M.H.; Engels, R.C.M.E.; Veerman, J.W.

    2012-01-01

    Background By interacting with children, group care workers shape daily living environments to influence treatment. Current literature provides little knowledge about the content of youth residential care. Objective In this study, a questionnaire called the Group care worker Intervention

  5. THE PULL FACTORS OF INTRA-URBAN RESIDENTIAL MOBILITY ...

    African Journals Online (AJOL)

    that the housing environment in most of the residential neighbourhoods is poor ... The colonial administration came to superimpose Western type of architecture in the ... middle and upper classes, mostly immigrants and these groups of ...

  6. Determinants of Residential Property Value in Nigeria – A Neural ...

    African Journals Online (AJOL)

    User

    This study investigated, by means of artificial intelligent system, the influence of residential ... impact on market values (prices) and to that extent influence the sales ... medical diagnosis, bank risk analysis, stock analysis & control, traffic control.

  7. 190 THE PUSH FACTORS OF INTRA-URBAN RESIDENTIAL ...

    African Journals Online (AJOL)

    Households move in search of residential satisfaction (Michelson, 1977). .... a move becomes a matter of action and not a reaction followed by an action. ... For example, man may first and foremost, look for safety and security in his housing.

  8. Cooperative Management for a Cluster of Residential Prosumers

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2016-01-01

    This paper proposes an energy management system for coordinating distributed prosumers. The prosumers are residential microgrids which internally produce and consume energy for autonomous operation. However, better performance is achieved by cooperative operation with other prosumers neighbors. E...

  9. Residents Living in Residential Care Facilities: United States, 2010

    Science.gov (United States)

    ... analyses, the 12% of residents chair-ridden or bedridden were defined as receiving assistance in the transferring ... MD: National Center for Health Statistics. 2011. Mollica R, Sims-Kastelein K, O'Keeffe J. Residential care ...

  10. The 2001 Residential Finance Survey - Owners Property File

    Data.gov (United States)

    Department of Housing and Urban Development — The 2001 Residential Finance Survey (RFS) was sponsored by the Department of Housing and Urban Development and conducted by the Census Bureau. The RFS is a follow-on...

  11. The 2001 Residential Finance Survey - Rental Property File

    Data.gov (United States)

    Department of Housing and Urban Development — The 2001 Residential Finance Survey (RFS) was sponsored by the Department of Housing and Urban Development and conducted by the Census Bureau. The RFS is a follow-on...

  12. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    generation characteristics, heat transfer and thermal dynamics of sustainable residential buildings and load scheduling potentials of household appliances with associated constraints. Through various simulation studies under different working scenarios with real data, different system constraints and user...

  13. Physical and chemical characterization of residential oil boiler emissions.

    Science.gov (United States)

    Hays, Michael D; Beck, Lee; Barfield, Pamela; Lavrich, Richard J; Dong, Yuanji; Vander Wal, Randy L

    2008-04-01

    The toxicity of emissions from the combustion of home heating oil coupled with the regional proximity and seasonal use of residential oil boilers (ROB) is an important public health concern. Yet scant physical and chemical information about the emissions from this source is available for climate and air quality modeling and for improving our understanding of aerosol-related human health effects. The gas- and particle-phase emissions from an active ROB firing distillate fuel oil (commonly known as diesel fuel) were evaluated to address this deficiency. Ion chromatography of impactor samples showed that the ultrafine ROB aerosol emissions were approximately 45% (w/w) sulfate. Gas chromatography-mass spectrometry detected various n-alkanes at trace levels, sometimes in accumulation mode particles, and out of phase with the size distributions of aerosol mass and sulfate. The carbonaceous matter in the ROB aerosol was primarily light-adsorbing elemental carbon. Gas chromatography-atomic emission spectroscopy measured a previously unrecognized organosulfur compound group in the ROB aerosol emissions. High-resolution transmission electron microscopy of ROB soot indicated the presence of a highly ordered primary particle nanostructure embedded in larger aggregates. Organic gas emissions were measured using EPA Methods TO-15 and TO-11A. The ROB emitted volatile oxygenates (8 mg/(kg of oil burned)) and olefins (5 mg/(kg of oil burned)) mostly unrelated to the base fuel composition. In the final analysis, the ROB tested was a source of numerous hazardous air pollutants as defined in the Clean Air Act Amendments. Approximations conducted using emissions data from the ROB tests show relatively low contributions to a regional-level anthropogenic emissions inventory for volitile organic compounds, PM2.5, and SO2 mass.

  14. Scalable Light Module for Low-Cost, High-Efficiency Light- Emitting Diode Luminaires

    Energy Technology Data Exchange (ETDEWEB)

    Tarsa, Eric [Cree, Inc., Goleta, CA (United States)

    2015-08-31

    During this two-year program Cree developed a scalable, modular optical architecture for low-cost, high-efficacy light emitting diode (LED) luminaires. Stated simply, the goal of this architecture was to efficiently and cost-effectively convey light from LEDs (point sources) to broad luminaire surfaces (area sources). By simultaneously developing warm-white LED components and low-cost, scalable optical elements, a high system optical efficiency resulted. To meet program goals, Cree evaluated novel approaches to improve LED component efficacy at high color quality while not sacrificing LED optical efficiency relative to conventional packages. Meanwhile, efficiently coupling light from LEDs into modular optical elements, followed by optimally distributing and extracting this light, were challenges that were addressed via novel optical design coupled with frequent experimental evaluations. Minimizing luminaire bill of materials and assembly costs were two guiding principles for all design work, in the effort to achieve luminaires with significantly lower normalized cost ($/klm) than existing LED fixtures. Chief project accomplishments included the achievement of >150 lm/W warm-white LEDs having primary optics compatible with low-cost modular optical elements. In addition, a prototype Light Module optical efficiency of over 90% was measured, demonstrating the potential of this scalable architecture for ultra-high-efficacy LED luminaires. Since the project ended, Cree has continued to evaluate optical element fabrication and assembly methods in an effort to rapidly transfer this scalable, cost-effective technology to Cree production development groups. The Light Module concept is likely to make a strong contribution to the development of new cost-effective, high-efficacy luminaries, thereby accelerating widespread adoption of energy-saving SSL in the U.S.

  15. PERMEABILITY MAP OF RESIDENTIAL SETTLEMENTS IN THE TROPICS

    OpenAIRE

    I Gusti Ngurah Antaryama

    2002-01-01

    Source of information for ventilation design of residential settlement is generally derived from wind tunnel or, recently, CFD studies, which involves both modeling and simulation of wind flow pattern and speed. Yet this is not readily accessible to most architects. In order to gain similar objectives but without involving detailed studies, the present study introduces a graphical method of gathering information about permeability of residential. It describes how the way wind reaches and flow...

  16. Investigating the factors affecting the investment decision in residential development.

    OpenAIRE

    Narang, Somil

    2007-01-01

    The purpose of this project is to provide a rare insight into the motivation behind residential property investors when looking to purchase an apartment. The factors driving demand preferences for housing are constantly changing, difficult to measure, and often deemed to be a complex bundle of attributes. The project attempts to answer the following questions: What are the factors affecting the investment decision in a Residential Development? To identify the significance and weight of su...

  17. AGA predicts winter jump in residential gas price

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The American Gas Association predicts the average heating bill for residential gas consumers could increase by as much as 18% this winter. AGA Pres. Mike Baly said, Last year's winter was warmer than normal. If the 1992-93 winter is similar, AGA projects that residential natural gas heating bills will go up about 6%. If we see a return to normal winter weather, our projection show the average bill could rise by almost 18%

  18. Older Men's Experiences of Moving Into Residential Care

    OpenAIRE

    Weighell, Simon

    2015-01-01

    Research examining the transition into residential aged care suggests that it can have a significant psychological and physiological impact upon older adults. There is a dearth of research examining the specific experiences of older men moving into and living in residential aged care. Older men may be at a significant disadvantage in managing the transition into care, particularly in context to; institutional living often characterised by increased dependency and a loss of control; physical d...

  19. Invisible Elderly in Danish and Swedish Residential Care Home Architecture

    DEFF Research Database (Denmark)

    E Andersson, Jonas; Grangaard, Sidse

    2015-01-01

    This study of two architectural competitions suggests that the fit between architectural design and older users, who depend on regular caregiving due to cognitive or functional disabilities, requires a particular consideration when designing new residential care homes.......This study of two architectural competitions suggests that the fit between architectural design and older users, who depend on regular caregiving due to cognitive or functional disabilities, requires a particular consideration when designing new residential care homes....

  20. Residential Solar Photovoltaics: Comparison of Financing Benefits, Innovations, and Options

    Energy Technology Data Exchange (ETDEWEB)

    Speer, B.

    2012-10-01

    This report examines relatively new, innovative financing methods for residential photovoltaics (PV) and compares them to traditional self-financing. It provides policymakers with an overview of the residential PV financing mechanisms, describes relative advantages and challenges, and analyzes differences between them where data is available. Because these innovative financing mechanisms have only been implemented in a few locations, this report can inform their wider adoption.

  1. Residential consumer behavior during and after an energy crisis

    Energy Technology Data Exchange (ETDEWEB)

    Aragao Neto, Raymundo [International Institute for Energy Conservation, Rio de Janeiro, RJ (Brazil)]. E-mail: raragao@iiec.org; Javaroni, Mario Cesar [ECOLUZ Consultores Associados, Rio de Janeiro, RJ (Brazil)]. E-mail: javaroni@ecoluz.com.br

    2004-07-01

    Brazil faced a severe energy crisis during 2001 and 2002 that reflected in all sectors including residential, and obliged to reduce in 20 per cent consumption, considering 2000 basis. New products were largely used, and domestic customs changed. This paper evaluates how residential behaviour has changed during the crisis period, and one year later what initiatives (habits, appliances) remained, considering a survey with 240 consumers. (author)

  2. Estimating the Determinants of Residential Water Demand in Italy

    OpenAIRE

    Giulia Romano; Nicola Salvati; Andrea Guerrini

    2014-01-01

    The aim of this study was to estimate the determinants of residential water demand for chief towns of every Italian province, in the period 2007–2009, using the linear mixed-effects model estimated with the restricted-maximum-likelihood method. Results confirmed that the applied tariff had a negative effect on residential water consumption and that it was a relevant driver of domestic water consumption. Moreover, income per capita had a positive effect on water consumption. Among measured cli...

  3. Lightness functions

    DEFF Research Database (Denmark)

    Campi, Stefano; Gardner, Richard; Gronchi, Paolo

    2012-01-01

    Variants of the brightness function of a convex body K in n-dimensional Euclidean are investigated. The Lambertian lightness function L(K; v , w ) gives the total reflected light resulting from illumination by a light source at infinity in the direction w that is visible when looking...... in the direction v . The partial brightness function R( K ; v , w ) gives the area of the projection orthogonal to v of the portion of the surface of K that is both illuminated by a light source from the direction w and visible when looking in the direction v . A class of functions called lightness functions...... is introduced that includes L(K;.) and R(K;.) as special cases. Much of the theory of the brightness function like uniqueness, stability, and the existence and properties of convex bodies of maximal and minimal volume with finitely many function values equal to those of a given convex body, is extended...

  4. Residential Mobility Across Early Childhood and Children's Kindergarten Readiness.

    Science.gov (United States)

    Mollborn, Stefanie; Lawrence, Elizabeth; Root, Elisabeth Dowling

    2018-04-01

    Understanding residential mobility in early childhood is important for contextualizing family, school, and neighborhood influences on child well-being. We examined the consequences of residential mobility for socioemotional and cognitive kindergarten readiness using the Early Childhood Longitudinal Study-Birth Cohort, a nationally representative longitudinal survey that followed U.S. children born in 2001 from infancy to kindergarten. We described individual, household, and neighborhood characteristics associated with residential mobility for children aged 0-5. Our residential mobility indicators examined frequency of moves, nonlinearities in move frequency, quality of moves, comparisons between moving houses and moving neighborhoods, and heterogeneity in the consequences of residential mobility. Nearly three-quarters of children moved by kindergarten start. Mobility did not predict cognitive scores. More moves, particularly at relatively high frequencies, predicted lower kindergarten behavior scores. Moves from socioeconomically advantaged to disadvantaged neighborhoods were especially problematic, whereas moves within a ZIP code were not. The implications of moves were similar across socioeconomic status. The behavior findings largely support an instability perspective that highlights potential disruptions from frequent or problematic moves. Our study contributes to literature emphasizing the importance of contextualizing residential mobility. The high prevalence and distinct implications of early childhood moves support the need for further research.

  5. Use of prismatic films to control light distribution

    Energy Technology Data Exchange (ETDEWEB)

    Kneipp, K.G. [3M Company Traffic Control, St. Paul, MN (United States)

    1994-12-31

    3M prismatic films are finding increasing utility in the construction of new hollow light guide fixtures which capitalize on the unique ways in which these novel materials interact with light. Often, the resulting systems provide features and end-user benefits which are difficult or impossible to achieve by alternative design or construction methods. It is apparent that the benefits may be applied to a wide variety of end-uses, and that the resulting products being developed will find utility in many diverse market areas. With the recognition that creating hollow light guide products and systems requires a substantial resource investment, and because of an existing prominent position in the traffic management market, 3M has decided to focus its current efforts in the development, manufacture, and distribution of value-added products for this market. However, through the sale of these prismatic films, a variety of companies have developed and are manufacturing and distributing other unrelated hollow light guide products which capitalize on the unique capabilities of these films in controlling and distributing light. There appears to be little doubt that the potential applications of this technology will grow both in numbers as well as in diversity.

  6. Orbiting compressor for residential air-conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Woo Young; Ahn, Jong Min [Department of Mechanical Engineering, University of Incheon, 12-1 Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea)

    2010-01-15

    A new type of compressor, called an orbiting compressor, is introduced in this paper. The orbiting compressor is characterized by an orbiting piston, and the piston or orbiter consists of a circular base plate and a ring type vane protruding vertically from the base plate. The orbiter is made to orbit in an annular space formed between two concentric circular walls via an Oldham-ring mechanism, producing two sealed gas pockets on both sides of the vane wrap with a 180 phase difference. This operating mechanism leads to alternating compression and discharge processes, which results in low torque variation. The orbiting compressor has been designed for an R410A residential air conditioner with a cooling capacity of 10.0 kW. The performance of the orbiting compressor model has been analytically investigated, where the volumetric, adiabatic and mechanical efficiencies were calculated to be 94.8%, 90.4% and 93.4%, respectively for the ARI condition. The EER was estimated to be about 10.86 with a motor efficiency of 89%. (author)

  7. Residential hot water distribution systems: Roundtablesession

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, James D.; Klein, Gary; Springer, David; Howard, Bion D.

    2002-08-01

    Residential building practice currently ignores the lossesof energy and water caused by the poor design of hot water systems. Theselosses include: combustion and standby losses from water heaters, thewaste of water (and energy) while waiting for hot water to get to thepoint of use; the wasted heat as water cools down in the distributionsystem after a draw; heat losses from recirculation systems and thediscarded warmth of waste water as it runs down the drain. Severaltechnologies are available that save energy (and water) by reducing theselosses or by passively recovering heat from wastewater streams and othersources. Energy savings from some individual technologies are reported tobe as much as 30 percent. Savings calculations of prototype systemsincluding bundles of technologies have been reported above 50 percent.This roundtable session will describe the current practices, summarizethe results of past and ongoing studies, discuss ways to think about hotwater system efficiency, and point to areas of future study. We will alsorecommend further steps to reduce unnecessary losses from hot waterdistribution systems.

  8. Residential construction cost: An Italian survey.

    Science.gov (United States)

    Canesi, Rubina; Marella, Giuliano

    2017-04-01

    This paper reports data describing development projects for new buildings according to construction costs in North-East Italy. A survey was carried out on local companies undertaking new residential development projects in two Italian regions (Veneto and Lombardy). The aim of this survey was to record new real estate construction projects, collecting both technical and socio-economic cost features. It is extremely difficult to collect such data for the Italian real estate construction sector, due to its lack of transparency, so that the novelty for the Italian scenario is the dataset itself. Another interest perspective of this survey is that socio-economic characteristics were also recorded; they are often studied in urban economics, but are usually related to property purchase prices and values, not to construction costs. The data come from an analysis of Canesi and Marella regarding the relationship between the trend of construction costs and the socio-economic conditions of the reference setting, such as the mean years of schooling of the workforce, housing market trends, and average per capita income.

  9. Residential construction cost: An Italian survey

    Directory of Open Access Journals (Sweden)

    Rubina Canesi

    2017-04-01

    Full Text Available This paper reports data describing development projects for new buildings according to construction costs in North-East Italy. A survey was carried out on local companies undertaking new residential development projects in two Italian regions (Veneto and Lombardy. The aim of this survey was to record new real estate construction projects, collecting both technical and socio-economic cost features. It is extremely difficult to collect such data for the Italian real estate construction sector, due to its lack of transparency, so that the novelty for the Italian scenario is the dataset itself. Another interest perspective of this survey is that socio-economic characteristics were also recorded; they are often studied in urban economics, but are usually related to property purchase prices and values, not to construction costs. The data come from an analysis of Canesi and Marella regarding the relationship between the trend of construction costs and the socio-economic conditions of the reference setting, such as the mean years of schooling of the workforce, housing market trends, and average per capita income.

  10. Mitigating residential exposure to secondhand tobacco smoke

    Science.gov (United States)

    Klepeis, Neil E.; Nazaroff, William W.

    In a companion paper, we used a simulation model to explore secondhand tobacco smoke (SHS) exposures for typical conditions in residences. In the current paper, we extend this analysis to evaluate the effectiveness of physical mitigation approaches in reducing nonsmokers' exposure to airborne SHS particulate matter in a hypothetical 6-zone house. Measures investigated included closing doors or opening windows in response to smoking activity, modifying location patterns to segregate the nonsmoker and the active smoker, and operating particle filtration devices. We first performed 24 scripted simulation trials using hypothetical patterns of occupant location. We then performed cohort simulation trials across 25 mitigation scenarios using over 1000 pairs of nonsmoker and smoker time-location patterns that were selected from a survey of human activity patterns in US homes. We limited cohort pairs to cases where more than 10 cigarettes were smoked indoors at home each day and the nonsmoker was at home for more than two thirds of the day. We evaluated the effectiveness of each mitigation approach by examining its impact on the simulated frequency distribution of residential SHS particle exposure. The two most effective strategies were the isolation of the smoker in a closed room with an open window, and a ban on smoking whenever the nonsmoker was at home. The use of open windows to supply local or cross ventilation, or the operation of portable filtration devices in smoking rooms, provided moderate exposure reductions. Closed doors, by themselves, were not effective.

  11. Remedial action of radium contaminated residential properties

    International Nuclear Information System (INIS)

    White, D.; Eng, J.

    1986-01-01

    Since November 1983, the New Jersey Department of Environmental Protection (NJDEP) and the US Environmental Protection Agency (USEPA) have been in the process of identifying properties in Montclair, Glen Ridge and West Orange, New Jersey, which were built over radium contaminated soil landfilled areas. Elevated indoor radon concentrations prompted the Centers for Disease Control (CDC) to issue a health advisory which included permanent remediation of radon progeny levels in excess of 0.02 Working Levels within two years of discovery. In order to expedite remedial action, NJDEP undertook a ten million dollar cleanup program. Remedial Action at the 12 residential properties encountered some unanticipated problems despite the efforts of numerous government agencies and their contractors to characterize the contamination as much as possible prior to remediation. Some of the unanticipated issues include contamination from other radionuclides, underestimation of removal volumes, and controversy over the transportation and disposal of the radium contaminated soil at a commercial facility in Nevada. This paper will review the approach taken by NJDEP to the remedial action for radium contaminated soil, discuss some of the issues encountered during the remedial action, and provide post remedial action data

  12. Energy options for residential buildings assessment

    International Nuclear Information System (INIS)

    Rezaie, Behnaz; Dincer, Ibrahim; Esmailzadeh, Ebrahim

    2013-01-01

    Highlights: ► Studying various building energy options. ► Assessing these options from various points. ► Comparing these options for better environment and sustainability. ► Proposing renewable energy options as potential solutions. - Abstract: The building sector, as one of the major energy consumers, demands most of the energy research to assess different energy options from various aspects. In this paper, two similar residential buildings, with either low or high energy consumption patterns, are chosen as case studies. For these case studies, three different renewable energy technology and three different hybrid systems are designed for a specified size. Then, the environmental impact indices, renewable energy indices, and the renewable exergy indices have been estimated for every energy options. Results obtained show that the hybrid systems (without considering the economics factors) are superior and having top indices. The importance of the energy consumption patterns in buildings are proven by the indices. By cutting the energy consumption to about 40% the environment index would increase by more than twice (2.1). Utilization of the non-fossil fuels is one part of the solution to environmental problems while energy conservation being the other. It has been shown that the re-design of the energy consumption model is less complex but more achievable for buildings.

  13. Residential exposures to pesticides and childhood leukaemia

    International Nuclear Information System (INIS)

    Metayer, C.; Buffler, P. A.

    2008-01-01

    Like many chemicals, carcinogenicity of pesticides is poorly characterised in humans, especially in children, so that the present knowledge about childhood leukaemia risk derives primarily from epidemiological studies. Overall, case-control studies published in the last decade have reported positive associations with home use of insecticides, mostly before the child's birth, while findings for herbicides are mixed. Previous studies relied solely on self-reports, therefore lacking information on active ingredients and effects of potential recall bias. Few series to date have examined the influence of children's genetic susceptibility related to transport and metabolism of pesticides. To overcome these limitations, investigators of the Northern California Childhood Leukaemia Study (NCCLS) have undertaken, in collaboration with a multidisciplinary team, a comprehensive assessment of residential pesticide exposure, including: (1) quality control of self-reports; (2) home pesticide inventory and linkage to the Environmental Protection Agency to obtain data on active ingredients; (3) collection and laboratory analyses of ∼600 home dust samples for over 60 pesticides and (4) geographic information studies using California environmental databases to assess exposure to agricultural pesticides. The NCCLS is also conducting large-scale geno-typing to evaluate the role of genes in xenobiotic pathways relevant to the transport and metabolism of pesticides. A better quantification of children's exposures to pesticides at home is critical to the evaluation of childhood leukaemia risk, especially for future gene-environment interaction studies. (authors)

  14. Optimizing Hydronic System Performance in Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L.; Faakye, O.

    2013-10-01

    Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

  15. National survey of residential magnetic field exposure

    International Nuclear Information System (INIS)

    Karipidis, K.K.

    2002-01-01

    The release of the Doll report in the UK, and its reported association between prolonged exposures to higher levels of power frequency magnetic fields and a small risk of leukaemia in children, has heightened community concerns. This disquiet among the general public has prompted the possibility of a national survey of residential magnetic field exposures to be implemented. Measurement methodologies were reviewed by the author and long-term measurements made by a logger placed in the living room for a 24-hour period were chosen as a surrogate measurement for the evaluation of exposure. An international comparison of similar surveys is presented, showing great deficiency, with the exception of Schuz et al and the UKCCS, in the number of homes surveyed. Factors influencing the selection of residences in the survey sample are elucidated and a range of sample sizes is presented with varying precision and confidence levels. Finally a feasible sample of 1,000 homes is chosen and a cost estimate is calculated with extra options for the measurement of the child's bedroom, a schools' survey and child personal exposure measurements included in the outlay. The purpose of the proposed national survey is to determine the proportion of Australian homes that are exposed to fields greater than 0.4 μT and the influence of proximity to powerlines as a cause. The study would also enable an interstate and international comparison of exposures to be made. Copyright (2002) Australasian Radiation Protection Society Inc

  16. Light sources and light pollution

    International Nuclear Information System (INIS)

    Pichler, G.

    2005-01-01

    From the dawn of mankind fire and light sources in general played an essential role in everyday life and protection over night. The development of new light sources went through many stages and is now an immense technological achievement, but also a threat for the wildlife at night, mainly because of the so-called light pollution. This paper discusses several very successful light sources connected with low pressure mercury and sodium vapour electric discharges. The luminous efficacy, colour rendering index and other lighting features cannot be always satisfactory, but at least some of the features can be much better than those met by the standard tungsten filament bulbs. High-pressure metal-vapour discharge lamps definitely have a good colour rendering index and a relatively high luminosity. Different light sources with burners at high pressure are discussed, paying special attention to their spectrum. The paper investigates new trends in development through a number of examples with non-toxic elements and pulsed electric discharge, which may be good news in terms of clean environment and energy savings. Light emitting diodes have recently appeared as worthy competitors to conventional light sources. White LEDs have approached 100 lumen/Watt efficacy in laboratories. This suggests that in some not very distant future they could completely replace high-pressure lamps, at least in indoor lighting. The article speculates on new developments which combine trends in nano technology and material science. The paper concludes with light pollution in view of several recent observations of plant and animal life at night in the vicinity of strong light sources. Photo-induced changes at the cell level may completely alter the normal life of plants and animals.(author)

  17. Emissions from residential combustion considering end-uses and spatial constraints: Part I, methods and spatial distribution

    Science.gov (United States)

    Winijkul, Ekbordin; Fierce, Laura; Bond, Tami C.

    2016-01-01

    This study describes a framework to attribute national-level atmospheric emissions in the year 2010 from the residential sector, one of the largest energy-related sources of aerosol emissions. We place special emphasis on end-uses, dividing usage into cooking, heating, lighting, and others. This study covers regions where solid biomass fuel provides more than 50% of total residential energy: Latin America, Africa, and Asia (5.2 billion people in 2010). Using nightlight data and population density, we classify five land types: urban, electrified rural with forest access, electrified rural without forest access, non-electrified rural with forest access, and non-electrified rural without forest access. We then apportion national-level residential fuel consumption among all land-types and end-uses, and assign end-use technologies to each combination. The resulting calculation gives spatially-distributed emissions of particulate matter, black carbon, organic carbon, nitrogen oxides, methane, non-methane hydrocarbons, carbon monoxide, and carbon dioxide. Within this study region, about 13% of the energy is consumed in urban areas, and 45% in non-urban land near forests. About half the energy is consumed in land without access to electricity. Cooking accounts for 54% of the consumption, heating for 9%, and lighting only 2%, with unidentified uses making up the remainder. Because biofuel use is assumed to occur preferentially where wood is accessible and electricity is not, our method shifts emissions to land types without electrification, compared with previous methods. The framework developed here is an important first step in acknowledging the role of household needs and local constraints in choosing energy provision. Although data and relationships described here need further development, this structure offers a more physically-based understanding of residential energy choices and, ultimately, opportunities for emission reduction.

  18. Risks from Radon: Reconciling Miner and Residential Epidemiology

    International Nuclear Information System (INIS)

    Chambers, Douglas B.; Harley, Naomi H.

    2008-01-01

    Everyone is exposed to radon, an inert radioactive gas that occurs naturally and is present everywhere in the atmosphere. The annual dose from radon and its (short-lived) decay products is typically about one-half of the dose received by members of the public from all natural sources of ionizing radiation. Data on exposures and consequent effects have recently been reviewed by the National Council on Radiation Protection and Measurements (NCRP) and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Studies of underground miners provides a well-established basis for estimating risks from occupational exposures to radon and for studying factors that may affect the dose response relationship such as the reduction of risk (coefficients) with increasing time since exposure. Miners' studies previously formed the basis for estimating risks to people exposed to radon at home, with downward extrapolation from exposures in mines to residential levels of radon. Presently, the risk estimates from residential studies are adequate to estimate radon risks in homes. Although there are major uncertainties in extrapolating the risks of exposure to radon from the miner studies to assessing risks in the home, there is remarkably good agreement between the average of risk factors derived from miner studies and those from pooled residential case-control studies. There are now over 20 analytical studies of residential radon and lung cancer. These studies typically assess the relative risk from exposure to radon based on estimates of residential exposure over a period of 25 to 30 years prior to diagnosis of lung cancer. Recent pooled analyses of residential case-control studies support a small but detectable lung cancer risk from residential exposure, and this risk increases with increasing concentrations. The excess relative risk of lung cancer from long-term residential exposure is about the same for both smokers and non-smokers; however, because the

  19. Financing Non-Residential Photovoltaic Projects: Options and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Bolinger, Mark

    2009-01-09

    Installations of grid-connected photovoltaic (PV) systems in the United States have increased dramatically in recent years, growing from less than 20 MW in 2000 to nearly 500 MW at the end of 2007, a compound average annual growth rate of 59%. Of particular note is the increasing contribution of 'non-residential' grid-connected PV systems--defined here as those systems installed on the customer (rather than utility) side of the meter at commercial, institutional, non-profit, or governmental properties--to the overall growth trend. Although there is some uncertainty in the numbers, non-residential PV capacity grew from less than half of aggregate annual capacity installations in 2000-2002 to nearly two-thirds in 2007. This relative growth trend is expected to have continued through 2008. The non-residential sector's commanding lead in terms of installed capacity in recent years primarily reflects two important differences between the non-residential and residential markets: (1) the greater federal 'Tax Benefits'--including the 30% investment tax credit (ITC) and accelerated tax depreciation--provided to commercial (relative to residential) PV systems, at least historically (this relative tax advantage has largely disappeared starting in 2009) and (2) larger non-residential project size. These two attributes have attracted to the market a number of institutional investors (referred to in this report as 'Tax Investors') seeking to invest in PV projects primarily to capture their Tax Benefits. The presence of these Tax Investors, in turn, has fostered a variety of innovative approaches to financing non-residential PV systems. This financial innovation--which is the topic of this report--has helped to overcome some of the largest barriers to the adoption of non-residential PV, and is therefore partly responsible (along with the policy changes that have driven this innovation) for the rapid growth in the market seen in recent years

  20. Innovative Solid State Lighting Replacements for Industrial and Test Facility Locations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is the replacement of existing test stand and parking lot fixtures with current SSL LED technology. The replacement fixtures will reduce...

  1. Fiscal 1994 research report. Demonstration test for establishing technology for peakload shaving with dispersed small residential PV systems (Evaluation of weatherability of house-use solar light electric power generating system equipment); 1994 nendo jutakuyo taiyoko hatsuden fuka heijunka gijutsu nado kakuritsu jissho shiken ni kansuru kaiseki hyoka no uchi jutakuyo taiyoko hatsuden system kiki no taikosei hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    Weatherability tests such as exposure to the atmosphere are conducted to collect and accumulate information on the degradation of house-use photovoltaic equipment expected to come into use in areas where weather conditions are hostile. Based on the thus collected data, analysis and evaluation are conducted about the mechanisms of corrosion and degradation for the establishment of designing and evaluating methods for maintaining weatherability. Since fiscal 1994 is the first year of the project, preparations are made for tests to be conducted. In carrying out research activities, a Weatherability Evaluation Committee for House-Use Solar Light Electric Power Generating System Equipment is organized, who discuss implementation of the project. Discussion is made on the shape and structural materials of the exposure rack. An aluminum alloy coated with a clear coating of alumite sulfate is selected, and a rack is built. Specifications of a sea salt particle collector are discussed, and preparations are made for arresting and quantifying sea salt particles under the Japanese Industrial Standard (JIS) dry gauze method and the International Organization for Standardization (ISO) wet candle method. Solar cell module initial characteristics are measured. (NEDO)

  2. Children's Urinary Environmental Carbon Load. A Novel Marker Reflecting Residential Ambient Air Pollution Exposure?

    Science.gov (United States)

    Saenen, Nelly D; Bové, Hannelore; Steuwe, Christian; Roeffaers, Maarten B J; Provost, Eline B; Lefebvre, Wouter; Vanpoucke, Charlotte; Ameloot, Marcel; Nawrot, Tim S

    2017-10-01

    Ambient air pollution, including black carbon, entails a serious public health risk because of its carcinogenic potential and as climate pollutant. To date, an internal exposure marker for black carbon particles that have cleared from the systemic circulation into the urine does not exist. To develop and validate a novel method to measure black carbon particles in a label-free way in urine. We detected urinary carbon load in 289 children (aged 9-12 yr) using white-light generation under femtosecond pulsed laser illumination. Children's residential black carbon concentrations were estimated based on a high-resolution spatial temporal interpolation method. We were able to detect urinary black carbon in all children, with an overall average (SD) of 98.2 × 10 5 (29.8 × 10 5 ) particles/ml. The urinary black carbon load was positively associated with medium-term to chronic (1 mo or more) residential black carbon exposure: +5.33 × 10 5 particles/ml higher carbon load (95% confidence interval, 1.56 × 10 5 to 9.10 × 10 5 particles/ml) for an interquartile range increment in annual residential black carbon exposure. Consistently, children who lived closer to a major road (≤160 m) had higher urinary black carbon load (6.93 × 10 5 particles/ml; 95% confidence interval, 0.77 × 10 5 to 13.1 × 10 5 ). Urinary black carbon mirrors the accumulation of medium-term to chronic exposure to combustion-related air pollution. This specific biomarker reflects internal systemic black carbon particles cleared from the circulation into the urine, allowing investigators to unravel the complexity of particulate-related health effects.

  3. Circadian light

    Directory of Open Access Journals (Sweden)

    Bierman Andrew

    2010-02-01

    Full Text Available Abstract The present paper reflects a work in progress toward a definition of circadian light, one that should be informed by the thoughtful, century-old evolution of our present definition of light as a stimulus for the human visual system. This work in progress is based upon the functional relationship between optical radiation and its effects on nocturnal melatonin suppression, in large part because the basic data are available in the literature. Discussed here are the fundamental differences between responses by the visual and circadian systems to optical radiation. Brief reviews of photometry, colorimetry, and brightness perception are presented as a foundation for the discussion of circadian light. Finally, circadian light (CLA and circadian stimulus (CS calculation procedures based on a published mathematical model of human circadian phototransduction are presented with an example.

  4. Bili lights

    Science.gov (United States)

    ... 3 things: Gestational age Bilirubin level in the blood Newborn's age (in hours) In severe cases of increased bilirubin, an exchange transfusion may be done instead. Alternative Names Phototherapy for jaundice; Bilirubin - bili lights; Neonatal ...

  5. Measuring urban tree loss dynamics across residential landscapes.

    Science.gov (United States)

    Ossola, Alessandro; Hopton, Matthew E

    2018-01-15

    The spatial arrangement of urban vegetation depends on urban morphology and socio-economic settings. Urban vegetation changes over time because of human management. Urban trees are removed due to hazard prevention or aesthetic preferences. Previous research attributed tree loss to decreases in canopy cover. However, this provides little information about location and structural characteristics of trees lost, as well as environmental and social factors affecting tree loss dynamics. This is particularly relevant in residential landscapes where access to residential parcels for field surveys is limited. We tested whether multi-temporal airborne LiDAR and multi-spectral imagery collected at a 5-year interval can be used to investigate urban tree loss dynamics across residential landscapes in Denver, CO and Milwaukee, WI, covering 400,705 residential parcels in 444 census tracts. Position and stem height of trees lost were extracted from canopy height models calculated as the difference between final (year 5) and initial (year 0) vegetation height derived from LiDAR. Multivariate regression models were used to predict number and height of tree stems lost in residential parcels in each census tract based on urban morphological and socio-economic variables. A total of 28,427 stems were lost from residential parcels in Denver and Milwaukee over 5years. Overall, 7% of residential parcels lost one stem, averaging 90.87 stems per km 2 . Average stem height was 10.16m, though trees lost in Denver were taller compared to Milwaukee. The number of stems lost was higher in neighborhoods with higher canopy cover and developed before the 1970s. However, socio-economic characteristics had little effect on tree loss dynamics. The study provides a simple method for measuring urban tree loss dynamics within and across entire cities, and represents a further step toward high resolution assessments of the three-dimensional change of urban vegetation at large spatial scales. Published by

  6. PEM - fuel cell system for residential applications

    Energy Technology Data Exchange (ETDEWEB)

    Britz, P. [Viessmann Werke GmbH and Co KG, 35107 Allendorf (Germany); Zartenar, N.

    2004-12-01

    Viessmann is developing a PEM fuel cell system for residential applications. The uncharged PEM fuel cell system has a 2 kW electrical and 3 kW thermal power output. The Viessmann Fuel Processor is characterized by a steam-reformer/burner combination in which the burner supplies the required heat to the steam reformer unit and the burner exhaust gas is used to heat water. Natural gas is used as fuel, which is fed into the reforming reactor after passing an integrated desulphurisation unit. The low temperature (600 C) fuel processor is designed on the basis of steam reforming technology. For carbon monoxide removal, a single shift reactor and selective methanisation is used with noble metal catalysts on monoliths. In the shift reactor, carbon monoxide is converted into hydrogen by the water gas shift reaction. The low level of carbon monoxide at the outlet of the shift reactor is further reduced, to approximately 20 ppm, downstream in the methanisation reactor, to meet PEM fuel cell requirements. Since both catalysts work at the same temperature (240 C), there is no requirement for an additional heat exchanger in the fuel processor. Start up time is less than 30 min. In addition, Viessmann has developed a 2 kW class PEFC stack, without humidification. Reformate and dry air are fed straight to the stack. Due to the dry operation, water produced by the cell reaction rapidly diffuses through the electrolyte membrane. This was achieved by optimising the MEA, the gas flow pattern and the operating conditions. The cathode is operated by an air blower. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  7. Radon: Residential attitudes toward the risk

    International Nuclear Information System (INIS)

    Fort, R.; Hinman, G.; Rosenman, R.; Wandschneider, P.

    1990-01-01

    Veradale, Washington (east of Spokane) is a region of high residential radon concentrations. Three hundred eighty residents of Veradale recently responded to a mail survey designed to elicit (1) their knowledge of and attitudes toward the risks of radon in their homes, (2) the actions they have taken or intend to take to identify and reduce those risks, and (3) policy preferences toward radon. Results reveal that these residents know that they live in an area with high radon levels, that radon causes lung cancer, and that radon will affect their health. However only 11% of respondents have had their homes tested for radon. This especially is puzzling because a large number of respondents claimed that (1) radon was important in home buying decisions, (2) they would test their own homes, (3) they would take action if such tests revealed problems, and (4) their willingness to pay for tests and improvements was well within the current costs of these actions. It remains a mystery why testing is at such a low level. Three other results are of note. First, subsidies for radon tests and home improvements may be having the unintended consequences of unneeded improvements and (potentially) moves without improvements. Second, individuals want radon testing required and results made known during home purchase decisions. Third, at present, weatherization programs that concentrate radon are acceptable to individuals. Of course, the future may hold different results. Administrators of weatherization programs, who are trusted by respondents according to this survey, would do well to institute weatherization programs with reduced radon concentrations in mind

  8. Vibration Analysis of a Residential Building

    Directory of Open Access Journals (Sweden)

    Sampaio Regina Augusta

    2015-01-01

    Full Text Available The aim of this paper is to present the results of a study regarding vibration problems in a 17 storey residential building during pile driving in its vicinity. The structural design of the building was checked according to the Brazilian standards NBR6118 and NBR6123, and using commercial finite element software. An experimental analysis was also carried out using low frequency piezo-accelerometers attached to the building structure. Structure vibrations were recorded under ambient conditions. Four monitoring tests were performed on different days. The objective of the first monitoring test was an experimental modal analysis. To obtain de modal parameters, data was processed in the commercial software ARTEMIS employing two methods: the Stochastic Subspace Identification and the Frequency Domain Decomposition. Human comfort was investigated considering the International Standard ISO 2631. The Portuguese standard, NP2074, was also used as a reference, since it aims to limit the adverse effects of vibrations in structures caused by pile driving in the vicinity of the structure. The carried out experimental tests have shown that, according to ISO2301, the measure vibration levels are above the acceptance limits. However, velocity peaks are below the limits established by NP2074. It was concluded that, although the structure has adequate capacity to resist internal forces according to normative criteria, it has low horizontal stiffness, which could be verified by observing the vibration frequencies and mode shapes obtained with the finite element models, and its similarity with the experimental results. Thus, the analyses indicate the occurrence of discomfort by the residents.

  9. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  10. Historic trends in the residential sector

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the OECD countries, income-driven growth in equipment ownership (heating, appliances) and home size drove household energy use up, but higher energy prices and conservation programs had a restraining effect. The results were mixed, with consumption per capita significantly lower in a few countries (United States, France), but higher in others. There was a significant decline in the intensity of space heating (30-40%) and a small decline in the intensity of electric applicances. Changes in the size and features of many appliances offset much of the improvement in technical energy efficiency. Not all of the decline in heating intensity was a result of technical change; the author estimates that about 25% was caused by change in heating behavior. In all, there were significant improvements in efficiency, but these were offset somewhat by structural change. In the Former East Bloc, there is far less residential space and amenity than in OECD countries, and efficiency of space heating and water heating is low, in part due to lake of energy pricing. Electric appliances are simple and relatively inefficient. Unlike in the OECD countries, there is little sign of improved efficiency in the 1970s and 1980s. In the LDCs, patterns of energy use, and changes in them, are very different in rural and urban areas, and vary among regions as well. Biomass is still the dominant fuel in rural areas. In urban areas, Western-like patterns of electricity (and even gas) use have emerged for appliances, cooking, and water heating among the affluent, and TV and refrigerators have become more common among the less-affluent. In many countries, especially in Southeast Asia, there has been very rapid growth in ownership of appliances. Most appliances are cheaply made and inefficient compared to similar appliances sold in the OECD countries, though there are signs of some improvement in the past decade. 16 refs., 11 figs., 9 figs

  11. Micro-CHP Systems for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Timothy DeValve; Benoit Olsommer

    2007-09-30

    Integrated micro-CHP (Cooling, Heating and Power) system solutions represent an opportunity to address all of the following requirements at once: conservation of scarce energy resources, moderation of pollutant release into our environment, and assured comfort for home-owners. The objective of this effort was to establish strategies for development, demonstration, and sustainable commercialization of cost-effective integrated CHP systems for residential applications. A unified approach to market and opportunity identification, technology assessment, specific system designs, adaptation to modular product platform component conceptual designs was employed. UTRC's recommendation to U.S. Department of Energy is to go ahead with the execution of the proposed product development and commercialization strategy plan under Phase II of this effort. Recent indicators show the emergence of micro-CHP. More than 12,000 micro-CHP systems have been sold worldwide so far, around 7,500 in 2004. Market projections predict a world-wide market growth over 35% per year. In 2004 the installations were mainly in Europe (73.5%) and in Japan (26.4%). The market in North-America is almost non-existent (0.1%). High energy consumption, high energy expenditure, large spark-spread (i.e., difference between electricity and fuel costs), big square footage, and high income are the key conditions for market acceptance. Today, these conditions are best found in the states of New York, Pennsylvania, New Jersey, Wisconsin, Illinois, Indiana, Michigan, Ohio, New England states. A multiple stage development plan is proposed to address risk mitigation. These stages include concept development and supplier engagement, component development, system integration, system demonstration, and field trials. A two stage commercialization strategy is suggested based on two product versions. The first version--a heat and power system named Micro-Cogen, provides the heat and essential electrical power to the

  12. Controlling Light Harvesting with Light

    NARCIS (Netherlands)

    Gwizdala, M.S.; Berera, R.; Kirilovsky, D.; van Grondelle, R.; Kruger, T.P.J.

    2016-01-01

    When exposed to intense sunlight, all organisms performing oxygenic photosynthesis implement various photoprotective strategies to prevent potentially lethal photodamage. The rapidly responding photoprotective mechanisms, occurring in the light-harvesting pigment-protein antennae, take effect within

  13. Factors Influencing the Usage of Compact Fluorescent Lamps in Existing Residential Buildings in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Olusola Olugbemileke Johnson

    2012-01-01

    Full Text Available Nigeria as a developing nation is facing increasing demand for electricity especially in the residential areas. The use of compact fluorescent lamps (CFLs is one of the several measures towards reducing the demand. However, in Nigeria, the use of CFLs is low. The present study was designed to investigate some factors responsible for the low usage of CFLs in Lagos, Nigeria. Questionnaires were administered by hand on 984 households, selected through systematic random sampling techniques from 5 local government areas in Lagos State. The first building along the major street in each of the local government was selected randomly and every tenth building constituted the sample. A household head was surveyed in each of the building selected, and was asked to rate some factors that might have influenced the usage of CFLs. The data generated from the questionnaire were analysed using ranking method. The findings show that inability to measure the saving benefits of CFLs on electricity bills, lack of affordability and high initial cost of acquisition and installation were the most important factors which influence the use of the CFLs. The study concludes by providing some recommendations on how to achieve sustainable energy management in the Lagos and beyond through more efficient residential house lighting.

  14. The residential segregation patterns of whites by socioeconomic status, 2000-2011.

    Science.gov (United States)

    Sharp, Gregory; Iceland, John

    2013-07-01

    In light of increasing racial and ethnic diversity, a recent housing crisis, and deep economic recession, arguments pertaining to the role of socioeconomic status (SES) in shaping patterns of racial/ethnic segregation remain salient. Using data from the 2000 decennial census and the 2007-2011 American Community Survey, we provide new evidence on the residential segregation patterns of whites from minorities by SES (income, education, and poverty). Results from our comprehensive analyses indicate that SES matters for the segregation patterns of whites from minorities. In particular, we find that whites as a whole are less segregated from higher-SES minority group members than lower-SES ones. Among whites, those of higher SES are more segregated from blacks and Hispanics as a whole and less segregated from Asians, indicating the importance of SES differentials across racial/ethnic groups in shaping residential patterns. We also find that during the 2000s, white-black segregation remained stable or declined, while whites became more segregated from Hispanics and Asians by all SES indicators. Fixed-effects models indicate that increasing white-minority SES segregation was fueled in part by increases in a metropolitan area's immigrant and elderly populations, minority poverty rate, and home values, while declining segregation was associated with rising education levels and new housing construction. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. The residential segregation patterns of whites by socioeconomic status, 2000–2011

    Science.gov (United States)

    Sharp, Gregory; Iceland, John

    2013-01-01

    In light of increasing racial and ethnic diversity, a recent housing crisis, and deep economic recession, arguments pertaining to the role of socioeconomic status (SES) in shaping patterns of racial/ethnic segregation remain salient. Using data from the 2000 decennial census and the 2007–2011 American Community Survey, we provide new evidence on the residential segregation patterns of whites from minorities by SES (income, education, and poverty). Results from our comprehensive analyses indicate that SES matters for the segregation patterns of whites from minorities. In particular, we find that whites as a whole are less segregated from higher-SES minority group members than lower-SES ones. Among whites, those of higher SES are more segregated from blacks and Hispanics as a whole and less segregated from Asians, indicating the importance of SES differentials across racial/ethnic groups in shaping residential patterns. We also find that during the 2000s, white-black segregation remained stable or declined, while whites became more segregated from Hispanics and Asians by all SES indicators. Fixed-effects models indicate that increasing white-minority SES segregation was fueled in part by increases in a metropolitan area’s immigrant and elderly populations, minority poverty rate, and home values, while declining segregation was associated with rising education levels and new housing construction. PMID:23721673

  16. In their own words: assessment of satisfaction with residential location among migrants in Nairobi slums.

    Science.gov (United States)

    Mudege, Netsayi Noris; Zulu, Eliya M

    2011-06-01

    Using qualitative data collected from a sample of rural-urban migrants over the age of 15 in two Nairobi slums interviewed in 2008, this paper discusses the migrants' extent of satisfaction with their residential location and decision to migrate. The study sheds light on why people continue to migrate to, and stay in, the rapidly growing slum settlements despite the high levels of poverty and poor health conditions in these areas. Tenure status is related to satisfaction for all ages. Environmental factors were frequently mentioned as a source of dissatisfaction. Life cycle and 'age-cohort effects' may also affect satisfaction for different age groups in terms of who is satisfied as well as the issues that are considered for satisfaction. High levels of dissatisfaction with slum life may be responsible for high out-migration in slum areas, although it does not mean that those who remain do so because they are satisfied. At the same time, challenges associated with slum life do not automatically signify dissatisfaction. Perceived success, as well as conditions in the area of origin can be used to explain and understand satisfaction/dissatisfaction with slum life. Satisfaction with migration and residential location may be related not only to the destination place, but also to events in the area of origin.

  17. LED Street Lighting Solutions: Flagstaff, Arizona as a Case Study

    Science.gov (United States)

    Hall, Jeffrey C.

    2018-01-01

    Dark-sky protection in Flagstaff, Arizona extends back to 1958, with the first ordinance in the City banning advertising floodlights. The current ordinance, adopted in 1989, is comprehensive and has played a critical role in maintaining the quality of the night sky for astronomy, tourism, public enjoyment, and other purposes. Flagstaff, like many communities around the world, is now working on a transition from legacy bulb-based technology to LED for its outdoor lighting. The City, Lowell Observatory, the U. S. Naval Observatory, and the Flagstaff Dark Skies Coalition have been working intensively for two years to identify an LED-based street lighting solution that will preserve the City's dark skies while meeting municipal needs. We will soon be installing test fixtures for an innovative solution incorporating narrow-band amber LED and modest amounts of low-CCT white LED. In this talk, I will review the types of LEDs available for outdoor lighting and discuss the plans for Flagstaff's street lighting in the LED era, which we hope will be a model for communities worldwide.

  18. Data mining application in industrial energy audit for lighting

    Energy Technology Data Exchange (ETDEWEB)

    Maricar, N.M.; Kim, G.C.; Jamal, N. [Kolej Univ., Melaka (Malaysia). Faculty of Electrical Engineering

    2005-07-01

    A data mining application for lighting energy audits at industrial sites was presented. Data collection was based on the parameters needed for the analysis part of the audit. Data collection included the activity for which the room was used; its dimension; light level readings in lux; the number of luminaries; the number of lamps per luminaries; lamp fixtures; and lamp wattage. The lumen method was used to calculate the recommended numbers of luminaries in the room. The number was then compared with the existing system's luminaries. The installed load efficacy ratio (ILER) was then used to determine proper retrofit action to maximize energy usage. The difference between the calculated lux and the standard lux was used to create data subsets. A data mining algorithm was used to determine that the ILER plays an important role in calculating the efficiency of lighting systems. It was also concluded that the method can be used to minimize the time needed to analyze large amounts of lighting data. The results of case studies were also used to show that the combined data mining algorithm provided accurate assessments using existing calculated data. 7 refs., 8 tabs., 5 figs.

  19. Influence of India’s transformation on residential energy demand

    International Nuclear Information System (INIS)

    Bhattacharyya, Subhes C.

    2015-01-01

    Highlights: • The middle income group emerges as the dominant segment by 2030. • Commercial residential energy demand increases 3–4 folds compared to 2010. • Electricity and LPG demand grows above 6% per year in the reference scenario. • India faces the potential of displacing the domination of biomass by 2030. - Abstract: India’s recent macro-economic and structural changes are transforming the economy and bringing significant changes to energy demand behaviour. Life-style and consumption behaviour are evolving rapidly due to accelerated economic growth in recent times. The population structure is changing, thereby offering the country with the potential to reap the population dividend. The country is also urbanising rapidly, and the fast-growing middle class segment of the population is fuelling consumerism by mimicking international life-styles. These changes are likely to have significant implications for energy demand in the future, particularly in the residential sector. Using the end-use approach of demand analysis, this paper analyses how residential energy demand is likely to evolve as a consequence of India’s transformation and finds that by 2030, India’s commercial energy demand in the residential sector can quadruple in the high scenario compared to the demand in 2010. Demand for modern fuels like electricity and liquefied petroleum gas is likely to grow at a faster rate. However, there is a window of opportunity to better manage the evolution of residential demand in India through energy efficiency improvement

  20. The value of residential photovoltaic systems: A comprehensive assessment

    Science.gov (United States)

    Borden, C. S.

    1983-01-01

    Utility-interactive photovoltaic (PV) arrays on residential rooftops appear to be a potentially attractive, large-scale application of PV technology. Results of a comprehensive assessment of the value (i.e., break-even cost) of utility-grid connected residential photovoltaic power systems under a variety of technological and economic assumptions are presented. A wide range of allowable PV system costs are calculated for small (4.34 kW (p) sub ac) residential PV systems in various locales across the United States. Primary factor in this variation are differences in local weather conditions, utility-specific electric generation capacity, fuel types, and customer-load profiles that effect purchase and sell-back rates, and non-uniform state tax considerations. Additional results from this analysis are: locations having the highest insolation values are not necessary the most economically attractive sites; residential PV systems connected in parallel to the utility demonstrate high percentages of energy sold back to the grid, and owner financial and tax assumptions cause large variations in break-even costs. Significant cost reduction and aggressive resolution of potential institutional impediments (e.g., liability, standards, metering, and technical integration) are required for a residential PV marker to become a major electric-grid-connected energy-generation source.

  1. A Neo-Rawlsian Approach to Residential Integration

    Directory of Open Access Journals (Sweden)

    Kevin J. Brown

    2013-08-01

    Full Text Available Over the past 40 years, the United States has engaged in various policies to integrate otherwise segregated black and white households within a shared space. However, little work has been done to fully articulate a moral argument for residential integration among black and white households. This paper offers what I refer to as the normative argument, which possesses two morally-impelled arguments for residential integration. Since the ethical appeal to integrate is often couched in the language of justice, I begin with a framework—based upon the work of the late philosopher John Rawls—for considering the moral aspects of residential integration. However, I go on to point out intractable problems related to the Rawlsian framework that would fail to flesh out all ethical considerations of the normative argument. From here, I provide a revised, or neo-Rawlsian, framework for understanding residential integration which addresses the aforementioned problems. This exercise is both important and necessary for the future of residential mixing, as better understanding the moral and ethical attributes of this discussion is, perhaps, the best means to lubricate the fundamental shift from 'spatial' to 'social' integration.

  2. Residential energy consumption: A convergence analysis across Chinese regions

    International Nuclear Information System (INIS)

    Herrerias, M.J.; Aller, Carlos; Ordóñez, Javier

    2017-01-01

    The process of urbanization and the raise of living standards in China have led an increasing trend in the patterns of residential consumption. Projections for the population growth rate in urban areas do not paint a very optimistic picture for energy conservation policies. In addition, the concentration of economic activities around coastal areas calls for new prospects to be formulated for energy policy. In this context, the objective of this paper is twofold. First, we analyse the effect of the urbanization process of the Chinese economy in terms of the long-run patterns of residential energy consumption at national level. By using the concept of club convergence, we examine whether electricity and coal consumption in rural and urban areas converge to the same long-run equilibrium or whether in fact they diverge. Second, the impact of the regional concentration of the economic activity on energy consumption patterns is also assessed by source of energy across Chinese regions from 1995 to 2011. Our results suggest that the process of urbanization has led to coal being replaced by electricity in urban residential energy consumption. In rural areas, the evidence is mixed. The club convergence analysis confirms that rural and urban residential energy consumption converge to different steady-states. At the regional level, we also confirm the effect of the regional concentration of economic activity on residential energy consumption. The existence of these regional clusters converging to different equilibrium levels is indicative of the need of regional-tailored set of energy policies in China.

  3. Synchrotron light

    International Nuclear Information System (INIS)

    2001-01-01

    'Synchrotron Light' is an interactive and detailed introduction to the physics and technology of the generation of coherent radiation from accelerators as well as to its widespread high-tech applications in science, medicine and engineering. The topics covered are the interaction of light and matter, the technology of synchrotron light sources, spectroscopy, imaging, scattering and diffraction of X-rays, and applications to materials science, biology, biochemistry, medicine, chemistry, food and pharmaceutical technology. All synchrotron light facilities are introduced with their home-page addresses. 'Synchrotron Light' provides an instructive and comprehensive multimedia learning tool for students, experienced practitioners and novices wishing to apply synchrotron radiation in their future work. Its multiple-entry points permit an easy exploration of the CD-Rom according to the users knowledge and interest. 2-D and 3-D animations and virtual reconstruction with computer-generated images guide visitors into the scientific and technical world of a synchrotron and into the applications of synchrotron radiation. This bilingual (English and French) CD-Rom can be used for self-teaching and in courses at various levels in physics, chemistry, engineering, and biology. (author)

  4. The Impact of Legislative Factor in the Identity of Modern Residential Urban in Iraq

    Directory of Open Access Journals (Sweden)

    Kadhim Faris Dhumad

    2017-02-01

    Full Text Available The Urban Residential has developed and changed in different periods of time with successive and gradual shifts, as it cast a shadow over the characterization of modern urbanism in Iraq. The semi-total absence of the governing legislation of urbanization as well as the weakness of the State's role of supervisory in addition to neglecting urban heritage contributed in offering a strange environment in relation to its traditional identity. That was increased by the pressure of the using urban environment as a result of the increasing of population as well as the growth of people’s needs. The research aims to provide an objective view for a mechanism of the application of urban legislation to monitor the implementation of the business relating to the urban structure in general and specifically the urban residential areas in order to preserve the traditional identity of the modern Iraqi city. For the purpose of treating the problem of research and to achieve its goals, the research supposes that the legislative system is based on a pyramid arrangement in its vocabulary, which is flexible in its application, and are drawn from objective reality, it can produce urban residential with local identity. The elements of the practical influential process of the legislative factor identified by the planning legislation, laws, regulations, controls and limitations, supervision and oversight. And then draw theoretical indicators which affect the urban environment, namely: proportionately, essence and appearance, construction and the sky line, the scale and size, bearings, cover-up, opening-up and containment through the study of a number of legislative irregularities in neighborhoods and residential areas that produced these indicators. For applying and testing these indicators practically, two selective neighborhoods in Al Rabeea'a District in Baghdad has been chosen and with a précised field survey the search findings are: the poverty of Urban elements

  5. Best practices guide for residential HVAC Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.

    2003-08-11

    This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various

  6. Mapping of residential radon in the world

    International Nuclear Information System (INIS)

    Zielinskia, Jan M.; Chambers, Douglas B.

    2008-01-01

    European countries (out of 46) with data. Using data from the database, we have created a map of national levels of residential radon around the world. In addition to static map, we have also implemented a preliminary web version and Google Earth version of the map. (author)

  7. Lighting and public health.

    NARCIS (Netherlands)

    Ierland, J. van & Schreuder, D.A.

    1969-01-01

    The following topics; are discussed with respect to public health: - the effect of visible and ultraviolet radiation upon man. - vision with respect to lighting. interior lighting. - artificial lighting of work environments. - day light and windows. - recommendations for lighting. public lighting. -

  8. Calculus light

    CERN Document Server

    Friedman, Menahem

    2011-01-01

    Another Calculus book? As long as students find calculus scary, the failure rate in mathematics is higher than in all other subjects, and as long as most people mistakenly believe that only geniuses can learn and understand mathematics, there will always be room for a new book of Calculus. We call it Calculus Light. This book is designed for a one semester course in ""light"" calculus -- mostly single variable, meant to be used by undergraduate students without a wide mathematical background and who do not major in mathematics but study subjects such as engineering, biology or management infor

  9. Lighting Design

    DEFF Research Database (Denmark)

    Hansen, Ellen Kathrine; Mullins, Michael

    2014-01-01

    of design developed from three experiments show how distinct qualitative and quantitative criteria in different disciplinary traditions can be integrated successfully, despite disparate technical/scientific, social scientific and art/humanities backgrounds. The model is applied to a pedagogical curriculum......Light as a multi-dimensional design element has fundamental importance for a sustainable environment. The paper discusses the need for an integration of scientific, technical and creative approaches to light and presents theory, methods and applications toward fulfilling this need. A theory...

  10. Integrated Urban System and Energy Consumption Model: Residential Buildings

    Directory of Open Access Journals (Sweden)

    Rocco Papa

    2014-05-01

    Full Text Available This paper describes a segment of research conducted within the project PON 04a2_E Smart Energy Master for the energetic government of the territory conducted by the Department of Civil, Architectural and Environment Engineering, University of Naples "Federico II".  In particular, this article is part of the study carried out for the definition of the comprehension/interpretation model that correlates buildings, city’s activities and users’ behaviour in order to promote energy savings. In detail, this segment of the research wants to define the residential variables to be used in the model. For this purpose a knowledge framework at international level has been defined, to estimate the energy requirements of residential buildings and the identification of a set of parameters, whose variation has a significant influence on the energy consumption of residential buildings.

  11. Residential Transitions among Adults with Intellectual Disability across 20 Years

    Science.gov (United States)

    Woodman, Ashley C.; Mailick, Marsha R.; Anderson, Kristy A.; Esbensen, Anna J.

    2014-01-01

    The present study addresses critical gaps in the literature by examining residential transitions among 303 adults with intellectual disability over 10 years (Part 1) and 75 adults with Down syndrome over 20 years (Part 2). All adults lived at home at the start of the study, but many moved to a variety of settings. Several characteristics of the adults with intellectual disability differed across settings, most notably adaptive behavior and the number of residential transitions, while characteristics such as age, type of disability, and behavior problems were less predictive of residential placements. The number of moves over the course of the study varied widely, with critical links to earlier family dynamics, social relationships, and health and adaptive behavior. PMID:25354121

  12. GENDER ROLE DISTRIBUTION IN RESIDENTIAL REAL ESTATE FAMILY DECISION MAKING

    Directory of Open Access Journals (Sweden)

    Irina R. KANCHEVA

    2017-12-01

    Full Text Available Purchase and consumption behavioral patterns of various family formations in different social and cultural contexts have been subject to intensive investigation over the recent years. Residential real estate as a product category represents one of the most complex household purchases incorporating a wide diversity of attributes to be considered in order to match family members’ needs within available resources. The purpose of this paper is to add some insights into spousal perceptions of gender role specialization throughout a residential real estate purchase family decision-making process. The distribution of influence between husbands and wives across three decision-making stages, three sub-decisions and twelve housing attribute choices and the relative importance of twelve residential real estate characteristics are examined using a convenience sample of both spouses in 127 Bulgarian heterosexual married and cohabiting couples.

  13. Residential radon and lung cancer incidence in a Danish cohort

    DEFF Research Database (Denmark)

    Bräuner, Elvira Vaclavik; Andersen, Claus Erik; Sørensen, Mette

    2012-01-01

    High-level occupational radon exposure is an established risk factor for lung cancer. We assessed the long-term association between residential radon and lung cancer risk using a prospective Danish cohort using 57,053 persons recruited during 1993–1997. We followed each cohort member for cancer...... occurrence until 27 June 2006, identifying 589 lung cancer cases. We traced residential addresses from 1 January 1971 until 27 June 2006 and calculated radon at each of these addresses using information from central databases regarding geology and house construction. Cox proportional hazards models were used...... to estimate incidence rate ratios (IRR) and 95% confidence intervals (CI) for lung cancer risk associated with residential radon exposure with and without adjustment for sex, smoking variables, education, socio-economic status, occupation, body mass index, air pollution and consumption of fruit and alcohol...

  14. The value of price transparency in residential solar photovoltaic markets

    Energy Technology Data Exchange (ETDEWEB)

    O’Shaughnessy, Eric; Margolis, Robert

    2018-06-01

    Installed prices for residential solar photovoltaic (PV) systems have declined significantly in recent years. However price dispersion and limited customer access to PV quotes prevents some prospective customers from obtaining low price offers. This study shows that improved customer access to prices - also known as price transparency - is a potential policy lever for further PV price reductions. We use customer search and strategic pricing theory to show that PV installation companies face incentives to offer lower prices in markets with more price transparency. We test this theoretical framework using a unique residential PV quote dataset. Our results show that installers offer lower prices to customers that are expected to receive more quotes. Our study provides a rationale for policies to improve price transparency in residential PV markets.

  15. The Sensitivity of Residential Electricity Demand in Indonesia

    Directory of Open Access Journals (Sweden)

    Stranti Nastiti Kusumaningrum

    2018-03-01

    Full Text Available Since 2013, the residential electricity price for High VA (Volt-Ampere households has changed due to changes in pricing policies. This paper analyzes the responsiveness of residential electricity demand to the change in electricity prices and income among two different household groups (Low VA and High VA in 2011 and 2014. Using an electricity consumption model and the Quantile Regression method, the results show that residential electricity demand is price and income inelastic. Income elasticity is lower than price elasticity. Furthermore, the effects on price elasticity also found in the Low VA group, whose rate remained stable. At the same time, evidence proves the impact of the change in pricing policy on income elasticity remains unclear. This result implies that the government has to be more careful in regulating electricity prices for the low VA group, while maintaining economic stability.DOI: 10.15408/sjie.v7i2.6048

  16. The association between anxiety sensitivity and motivation to quit smoking among women and men in residential substance use treatment.

    Science.gov (United States)

    Dahne, Jennifer; Hoffman, Elana M; MacPherson, Laura

    2015-01-01

    Smoking-attributed mortality is the leading cause of death among individuals in residential substance use treatment. As such, identifying factors that influence smoking cessation is highly relevant and important for this group. Motivation to quit (MTQ) smoking is one such factor that is related to smoking cessation. In the present study we examine the relationship between Anxiety Sensitivity (AS) and MTQ among individuals enrolled in a residential substance use treatment center in Washington, DC. In light of gender differences in smoking cessation as well as factors that contribute to cessation, we examined this relationship by gender in men and women using multiple group path analysis. Participants (n = 472) completed a measure of MTQ, the structured clinical interview for DSM-IV (SCID-IV-TR), a measure of AS, and self-reported their number of cigarettes smoked per day prior to entering a restricted environment. RESULTS indicated that AS was significantly related to MTQ in women (standardized path estimate = 0.21, p = .01), but was not significantly related to MTQ in men. Conclusions/Importance: Findings suggest the importance of considering AS as a factor in MTQ for women and subsequent smoking cessation among individuals in residential substance use treatment. RESULTS of this study contribute to the extant literature on predictors of MTQ and highlight the need for tailored cessation interventions with AS as one potential cessation treatment target.

  17. Potential market-size for renewables in the residential sector of Pakistan

    International Nuclear Information System (INIS)

    Athar, G.R; Imtiaz, M.

    2005-01-01

    Renewable energy-sources can be used for meeting the energy-demand of various endues, like water-pumping for irrigation, process-heat for industries and desalination for potable water-supplies. However, the residential sector has the largest potential for renewable energy usage among all sectors of the economy. At present, the residential sector of Pakistan consumes some 26 million Tone of Oil Equivalent (MTOE) energy: with more than 6 MTOE in the form of commercial energy (electricity, natural gas, kerosene, LPG and coal) and about 20 MTOE in the form of non-commercial energy (wood, dung and crop-residues). Applied Systems Analysis Group (ASAG) has carried out a study to project the energy demand of Pakistan up to the year 2024-25, using an energy-demand model MAED. This model uses simulation technique to evaluate the energy-demand implications of a scenario, describing the assumed evolution of demographic parameters, economic activities, lifestyle of the population and technological improvements. The demographic targets of the Population-Policy of Pakistan and economic targets of Government of Pakistan have been adopted as the basis of our reference scenario. The study shows that the energy-demand of the residential sector will increase by a factor of 1.7, compared to the base-year 2001-2002. The residential sector will need 41. 9 MTOE energy, of which: (I) 5.9 MTOE (72.5 TWh) in the form of electricity to fulfill the energy-needs for lighting, cooling and other electric appliances, (II) 24.4 MTOE for cooking, (III) 5.7 MTOE for water heating, and (IV) 5.8 MTOE for space heating. In all these end-uses, renewable energy can make a contribution depending on the cost of energy, convenience of use and reliability of supply. Although, the government is vigorously pursuing a rural electrification program, a portion of residential sector, particularly in remote areas, will not be electrified even by 2024-25. The non-electrified houses will require 3 to 5 TWh of

  18. Internal heat gain from different light sources in the building lighting systems

    Directory of Open Access Journals (Sweden)

    Suszanowicz Dariusz

    2017-01-01

    Full Text Available EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.

  19. Internal heat gain from different light sources in the building lighting systems

    Science.gov (United States)

    Suszanowicz, Dariusz

    2017-10-01

    EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output) were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.

  20. Qualitative exploration of relationships between peers in residential addiction treatment.

    Science.gov (United States)

    Neale, Joanne; Tompkins, Charlotte N E; Strang, John

    2018-01-01

    Relationships between peers are often considered central to the therapeutic process, yet there is relatively little empirical research either on the nature of peer-to-peer relationships within residential treatment or on how those relationships generate positive behaviour change or facilitate recovery. In this paper, we explore relationships between peers in residential addiction treatment, drawing upon the concept of social capital to frame our analyses. Our study was undertaken during 2015 and 2016 in two English residential treatment services using the same therapeutic community-informed model of treatment. We conducted 22 in-depth interviews with 13 current and 9 former service residents. All interviews were audio-recorded, transcribed verbatim, coded in MAXQDA, and analysed using Iterative Categorisation. Residents reported difficult relationship histories and limited social networks on entry into treatment. Once in treatment, few residents described bonding with their peers on the basis of shared experiences and lifestyles. Instead, interpersonal differences polarised residents in ways that undermined their social capital further. Some senior peers who had been in residential treatment longer acted as positive role models, but many modelled negative behaviours that undermined others' commitment to treatment. Relationships between peers could generate feelings of comfort and connectedness, and friendships developed when residents found things in common with each other. However, residents more often reported isolation, loneliness, wariness, bullying, manipulation, intimidation, social distancing, tensions and conflict. Overall, relationships between peers within residential treatment seemed to generate some positive but more negative social capital; undermining the notion of the community as a method of positive behaviour change. With the caveat that our data have limitations and further research is needed, we suggest that residential treatment providers should

  1. Evaluation of daylight intensity for sustainbility in residential buildings in cantonment cottages multan

    International Nuclear Information System (INIS)

    Yousuf, S.; Maqsood, S.

    2017-01-01

    Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. In order to evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers). After investigation, it has been found that daylight factor is much higher than the standard values as per recommended by CIBSE. The design parameters including building orientation, glazing area, room size to window opening ratio etc. is not appropriate with respect to sustainable design. (author)

  2. Ethnic Residential Segregation in the United Kingdom by Age Group: the Case of Bradford

    Directory of Open Access Journals (Sweden)

    David McEvoy

    2009-08-01

    Full Text Available There is a long running debate on the significance of ethnic residential segregation levels in Britain. These phenomena have been related to the extent of community cohesion in British cities, and particularly to the riots of 2001 in the north of England. Further light is cast on these issues by examining ethnic segregation by age in the case of Bradford, the location of the largest riot. Both the dissimilarity index and the exposure index are used to consider relations between the White British and the largest minorities at ward level and at census output area level. The level of segregation is shown to vary with age, usually in a consistent direction. The direction varies between ethnic groups however.

  3. Residential segregation and overweight/obesity among African-American adults: A critical review

    Directory of Open Access Journals (Sweden)

    Irma eCorral

    2015-07-01

    Full Text Available The relationship between residential segregation and overweight/obesity among African-American adults remains unclear. Elucidating that relationship is relevant to efforts to prevent and to reduce racial disparities in obesity. This article provides a critical review of the 11 empirical studies of segregation and overweight/obesity among African-American adults. Results revealed that most studies did not use a valid measure of segregation, many did not use a valid measure of overweight/obesity, and many did not control for neighborhood poverty. Only four (36% of the studies used valid measures of both segregation and overweight/obesity and also controlled for area-poverty. Those four studies suggest that segregation contributes to overweight and obesity among African-American adults, but that conclusion cannot be drawn with any certainty in light of the considerable methodological problems in this area of research. Suggestions for improving research on this topic are provided.

  4. Data report for the Southwest Residential Experiment Station, January 1982

    Energy Technology Data Exchange (ETDEWEB)

    Lieberman, M.; Hai, O. Y.; Hocking, G.; Whitaker, C.

    1982-02-23

    Physical performance data obtained from the photovoltaic energy systems under test at the Southwest Residential Experiment Station in Las Cruces, New Mexico are tabulated and graphed for the month of January, 1982. Data drawn from the Residential Data System (RDS) appears in several formats. A one-page summary is provided as well as a more detailed hour-by-hour tabulation for an average day of the month. Energy histograms are provided, based on RDS data and recording kilowatt hour meters. The histograms also present horizontal and plane-of-array insolation data as well as comments that explain data and/or energy production anomalies. (LEW)

  5. The aging US population and residential energy demand

    International Nuclear Information System (INIS)

    Tonn, Bruce; Eisenberg, Joel

    2007-01-01

    This piece explores the relationships between a rapidly aging U.S. population and the demand for residential energy. Data indicate that elderly persons use more residential energy than younger persons. In this time of steeply rising energy costs, energy is an especially important financial issue for the elderly with low and/or fixed incomes. As the absolute number of elderly as well as their proportion of the total US population both continue to increase, energy and the elderly population looms as another energy policy challenge

  6. Energy and IAQ Implications of Residential Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    This study evaluates the energy, humidity and indoor air quality (IAQ) implications of residential ventilation cooling in all U.S. IECC climate zones. A computer modeling approach was adopted, using an advanced residential building simulation tool with airflow, energy and humidity models. An economizer (large supply fan) was simulated to provide ventilation cooling while outdoor air temperatures were lower than indoor air temperatures (typically at night). The simulations were performed for a full year using one-minute time steps to allow for scheduling of ventilation systems and to account for interactions between ventilation and heating/cooling systems.

  7. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...... the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  8. Development of a Smart Residential Fire Protection System

    Directory of Open Access Journals (Sweden)

    Juhwan Oh

    2013-01-01

    Full Text Available Embedded system is applied for the development of smart residential fire detection and extinguishing system. Wireless communication capability is integrated into various fire sensors and alarm devices. The system activates the fire alarm to warn occupants, executes emergency and rescue calls to remote residents and fire-fighting facility in an intelligent way. The effective location of extra-sprinklers within the space of interest for the fire extinguishing system is also investigated. Actual fire test suggests that the developed wireless system for the smart residential fire protection system is reliable in terms of sensors and their communication linkage.

  9. LIGHT TITRATIONS

    Science.gov (United States)

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  10. Environmental assessment in support of proposed voluntary energy conservation standard for new residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, D.L.; Parker, G.B.; Callaway, J.W.; Marsh, S.J.; Roop, J.M.; Taylor, Z.T.

    1989-06-01

    The objective of this environmental assessment (EA) is to identify the potential environmental impacts that could result from the proposed voluntary residential standard (VOLRES) on private sector construction of new residential buildings. 49 refs., 15 tabs.

  11. Relations between residential and workplace segregation among newly arrived immigrant men and women

    NARCIS (Netherlands)

    Tammaru, T.; Strömgren, M.; Van Ham, M.; Danzer, A.M.

    2016-01-01

    Contemporary cities are becoming more and more diverse in population as a result of immigration. Research shows that while residential neighborhoods are becoming ethnically more diverse within cities, residential segregation from natives has overall remained persistently high. High levels of

  12. EnviroAtlas - Population and Residential Activity in the Conterminous U.S. Web Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas web service includes maps that illustrate population and residential activity in each census block group as well as residential-location-based...

  13. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in South Carolina. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in South Carolina.

  14. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Nebraska. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Nebraska.

  15. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Wisconsin

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Wisconsin. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Wisconsin.

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Pennsylvania. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Pennsylvania.

  17. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Nevada. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Nevada.

  18. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Texas

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Texas. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Texas.

  19. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Oklahoma

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Oklahoma. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Oklahoma.

  20. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Missouri

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Missouri. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Missouri.

  1. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Rhode Island

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Rhode Island. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Rhode Island.

  2. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in New Mexico. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New Mexico.

  3. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for North Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in North Dakota. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in North Dakota.

  4. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Ohio. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Ohio.

  5. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Massachusetts. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Massachusetts.

  6. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Vermont

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Vermont. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Vermont.

  7. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Mississippi

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Mississippi. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Mississippi.

  8. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Virginia

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Virginia. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Virginia.

  9. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Wyoming. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Wyoming.

  10. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for West Virginia

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in West Virginia. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in West Virginia.

  11. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Utah

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Utah. Moving to the 2015 IECC from the 2012 Utah State Code base code is cost-effective for residential buildings in all climate zones in Utah.

  12. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Tennessee. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Tennessee.

  13. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for South Dakota

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in South Dakota. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in South Dakota.

  14. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Michigan. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Michigan.

  15. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Minnesota

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Minnesota. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Minnesota.

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Montana

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Montana. Moving to the 2015 IECC from the 2014 Montana State Code base code is cost-effective for residential buildings in all climate zones in Montana.

  17. Influence of the residential and work environment on car use in dual-earner households

    NARCIS (Netherlands)

    Maat, K.; Timmermans, H.J.P.

    2009-01-01

    This paper analyses whether the decision to commute by car is influenced by built environment characteristics of residential neighbourhoods and, more especially, of work locations, taking into account interdependencies between household partners. It shows that the residential environment only

  18. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for New York

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in New York. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New York.

  19. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Alabama. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Alabama.

  20. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    Mendon, Vrushali V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Taylor, Zachary T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poehlman, Eric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Louisiana. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Louisiana.