WorldWideScience

Sample records for residential electric heat

  1. Experimental device for the residential heating with heat pipe and electric heat storage blocks

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Boldak, I M; Domorod, L S; Rabetsky, M I; Schirokov, E I [AN Belorusskoj SSR, Minsk (Belarus). Inst. Teplo- i Massoobmena

    1992-01-01

    Residential heating using electric heat storage blocks nowadays is an actual problem from the point of view of heat recovery and nature protection. In the Luikov Heat and Mass Transfer Institute a new residential electrical heater capable of heating chambers by controlling air temperature and heat output using heat pipes and an electric heat storage block was developed. This heater (BETA) is fed from the source of energy and during 7 h of night time accumulates energy sufficiently to heat 10 m{sup 3} during 24 h. Heating device BETA has a ceramic thermal storage block, electric heaters and a heat pipe with evaporator inside the ceramic block and constant temperature (65{sup o}C) finned condenser outside it. The condenser temperature could be controlled easily. BETA is compact, has high thermal response, accurate air temperature control and safe operation. Such types of residential heaters are necessary for heating residential and office building in the Mogilev and Gomel regions in Byelorussia which suffered after the Chernobyl catastrophe. (Author).

  2. Meeting residential space heating demand with wind-generated electricity

    International Nuclear Information System (INIS)

    Hughes, Larry

    2010-01-01

    Worldwide, many electricity suppliers are faced with the challenge of trying to integrate intermittent renewables, notably wind, into their energy mix to meet the needs of those services that require a continuous supply of electricity. Solutions to intermittency include the use of rapid-response backup generation and chemical or mechanical storage of electricity. Meanwhile, in many jurisdictions with lengthy heating seasons, finding secure and preferably environmentally benign supplies of energy for space heating is also becoming a significant challenge because of volatile energy markets. Most, if not all, electricity suppliers treat these twin challenges as separate issues: supply (integrating intermittent renewables) and demand (electric space heating). However, if space heating demand can be met from an intermittent supply of electricity, then both of these issues can be addressed simultaneously. One such approach is to use off-the-shelf electric thermal storage systems. This paper examines the potential of this approach by applying the output from a 5.15 MW wind farm to the residential heating demands of detached households in the Canadian province of Prince Edward Island. The paper shows that for the heating season considered, up to 500 households could have over 95 percent of their space heating demand met from the wind farm in question. The benefits as well as the limitations of the approach are discussed in detail. (author)

  3. Modeling hourly consumption of electricity and district heat in non-residential buildings

    International Nuclear Information System (INIS)

    Kipping, A.; Trømborg, E.

    2017-01-01

    Models for hourly consumption of heat and electricity in different consumer groups on a regional level can yield important data for energy system planning and management. In this study hourly meter data, combined with cross-sectional data derived from the Norwegian energy label database, is used to model hourly consumption of both district heat and electrical energy in office buildings and schools which either use direct electric heating (DEH) or non-electric hydronic heating (OHH). The results of the study show that modeled hourly total energy consumption in buildings with DEH and in buildings with OHH (supplied by district heat) exhibits differences, e.g. due to differences in heat distribution and control systems. In a normal year, in office buildings with OHH the main part of total modeled energy consumption is used for electric appliances, while in schools with OHH the main part is used for heating. In buildings with OHH the share of modeled annual heating energy is higher than in buildings with DEH. Although based on small samples our regression results indicate that the presented method can be used for modeling hourly energy consumption in non-residential buildings, but also that larger samples and additional cross-sectional information could yield improved models and more reliable results. - Highlights: • Schools with district heating (DH) tend to use less night-setback. • DH in office buildings tends to start earlier than direct electric heating (DEH). • In schools with DH the main part of annual energy consumption is used for heating. • In office buildings with DH the main part is used for electric appliances. • Buildings with DH use a larger share of energy for heating than buildings with DEH.

  4. Users of electric heating rewarded

    Energy Technology Data Exchange (ETDEWEB)

    Haapakoski, M. [ed.

    1998-07-01

    When the building industry plunged into the deep recession of the early 1990s this did not paralyse research and development work on electric heating. In fact, IVO and power companies launched the `Electrically Heated Homes in the New Millennium` project in 1992. Its purpose was to verify the efficiency, energy economy and residential comfort of model systems using state-of-the-art electric heating technology. The research project launched six years ago is now nearing completion. Its findings indicate that electricity brings ever more unparalleled benefits when it is used for heating. These benefits involve residential comfort, ease of use and economy

  5. Energy in the residential building. Electricity, heat, e-mobility. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Schwarzburger, Heiko

    2017-01-01

    Photovoltaics, heat pumps and fuel cells offer enormous potential for sustainable energy supply in residential buildings. Solar thermal energy and wood-fired boilers also play an important role in refurbishment. Due to the wide range of possible combinations, the wishes of building owners and homeowners for an ecologically and economically individually adapted energy concept can be fulfilled accurately. This book provides you with a holistic approach to the residential building and its supply of electricity, heat and water. All processes that play a role in the house's energy consumption are examined in their entirety for their potentials and potential savings. The author analyses and describes in detail the resources of buildings and their surroundings - and how they can be used for a truly independent supply. The focus is on reducing energy consumption and costs, the generation and supply of energy from renewable sources and energy storage - considered in new construction and modernisation. The supply of water is also dealt with if it touches on energy issues. The author draws attention to standards and regulations and gives practical advice for planning and installation. The focus is on the so-called sector coupling: electricity from the sun, wind and hydrogen is used to supply electrical consumers in the home, charging technology for electric vehicles, hot water and heating. The time of the boilers and combustion engines has elapsed. Clean electricity and digital controls - power and intelligence - determine the regenerative building technology. [de

  6. Retailing residential electricity : A concept that makes sense?

    International Nuclear Information System (INIS)

    MacDonald, C.

    2003-07-01

    A heated debate centres around the deregulation of the electricity industry and the retailing of residential electricity. An assessment of the current situation in the industry was provided in this paper to provide a basis for discussion. The experience gained both in Alberta and Texas in residential retail was examined. The main issue of concern is whether residential customers will benefit from deregulation of the electricity sector. The Retail Energy Deregulation (RED) Index provides a benchmark for those jurisdictions considering the residential options. Deregulation has not led to significant benefits to residential customers in most jurisdictions. The electricity industry will always require a central dispatch/market process that will have to designed, governed, regulated, modified regularly. The benefits to residential consumers are not expected for a very long time. Standard market design is an issue that will require attention. refs., 7 figs

  7. Economic analysis of electric heating based on critical electricity price

    Science.gov (United States)

    Xie, Feng; Sun, Zhijie; Zhou, Xinnan; Fu, Chengran; Yang, Jie

    2018-06-01

    The State Grid Corporation of China proposes an alternative energy strategy, which will make electric heating an important task in the field of residential electricity consumption. This article takes this as the background, has made the detailed introduction to the inhabitant electric heating technology, and take the Zhangjiakou electric panels heating technology as an example, from the expense angle, has carried on the analysis to the electric panels heating economy. In the field of residential heating, electric panels operating costs less than gas boilers. After customers implying energy-saving behavior, electric panels operating cost is even lower than coal-fired boilers. The critical price is higher than the execution price, which indicates that the economic performance of the electric panels is significantly higher than that of the coal boiler.

  8. Residential heat pumps in the future Danish energy system

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    for politically agreed targets which include: at least 50% of electricity consumption from wind power starting from 2020, fossil fuel free heat and power sector from 2035 and 100% renewable energy system starting from 2050. Residential heat pumps supply around 25% of total residential heating demand after 2035......Denmark is striving towards 100% renewable energy system in 2050. Residential heat pumps are expected to be a part of that system.We propose two novel approaches to improve the representation of residential heat pumps: Coefficients of performance (COPs) are modelled as dependent on air and ground...... temperature while installation of ground-source heat pumps is constrained by available ground area. In this study, TIMES-DK model is utilised to test the effects of improved modelling of residential heat pumps on the Danish energy system until 2050.The analysis of the Danish energy system was done...

  9. Residential Electricity Consumption in Poland

    Directory of Open Access Journals (Sweden)

    Edyta Ropuszyńska-Surma

    2016-01-01

    Full Text Available Key factors influencing electricity consumption in the residential sector in Poland have been identified. A fixed-effects model was used, which includes time effects, and a set of covariates, based on the model developed by Houthakker et al. This model estimates electricity demand by using lagged values of the dependent variable along with current and lagged values of electricity prices, and other variables that affect electricity demand such as: population, economic growth, income per capita, price of related goods, etc. The model has been identified according to the research results of the authors and those obtained by Bentzen and Engsted. The set of covariates was extended to the lagged electricity price given by a tariff (taken from two years previous to the time of interest and heating degree days index, a very important factor in European Union countries, where the climate is temperate. The authors propose four models of residential electricity demand, for which a confidence interval of 95% has been assumed. Estimation was based on Polish quarterly data for the years 2003-2013. (original abstract

  10. Gas-heating alternatives to the residential electric heat pump. Gas Appliance Technology Center 1987 program. Topical report for Work Area 1.1, October 1989-March 1990

    International Nuclear Information System (INIS)

    Haas, C.

    1990-05-01

    The characteristics of electric heat pumps are described. Options are defined and assessed for utilizing gas heating in conjunction with existing residential electric heat pumps. These options include gas heat introduced into the refrigeration circuit, a flue gas-heated tube bank in the air supply duct, and a hot-water-to-air coil in the supply duct. Economics are presented for conversion of a residence's total space and water heating from electric to gas in New York City and Atlanta. Potential marketing strategies are discussed, and potential gas sales volumes from conversions are estimated. The study concludes that the use of gas water heating coupled with a hydronic coil in the supply ductwork from the air handler is the most advantageous option for the gas industry

  11. Quebec residential electricity demand: a microeconometric approach

    International Nuclear Information System (INIS)

    Bernard, J.T.; Bolduc, D.; Belanger, D.

    1996-01-01

    An economic analysis of Quebec residential electricity demand was studied by micro-simulation models. These structural models describe all components which lead to decisions upon durable holdings and electric appliance usage. The demand for space and water heating systems was evaluated. Recent price change in favour of energy sources other than electricity were taken into account. Price and income elasticity ratios were found to be low, as expected when estimating short term use. The role played by socio-economic variables on the choice of space-water heating systems and electricity use was also examined. Recent conversions have indicated a trend toward preference by households in favour of natural gas or oil over electricity. 18 refs., 5 tabs., 1 fig

  12. Exploring variance in residential electricity consumption: Household features and building properties

    International Nuclear Information System (INIS)

    Bartusch, Cajsa; Odlare, Monica; Wallin, Fredrik; Wester, Lars

    2012-01-01

    Highlights: ► Statistical analysis of variance are of considerable value in identifying key indicators for policy update. ► Variance in residential electricity use is partly explained by household features. ► Variance in residential electricity use is partly explained by building properties. ► Household behavior has a profound impact on individual electricity use. -- Abstract: Improved means of controlling electricity consumption plays an important part in boosting energy efficiency in the Swedish power market. Developing policy instruments to that end requires more in-depth statistics on electricity use in the residential sector, among other things. The aim of the study has accordingly been to assess the extent of variance in annual electricity consumption in single-family homes as well as to estimate the impact of household features and building properties in this respect using independent samples t-tests and one-way as well as univariate independent samples analyses of variance. Statistically significant variances associated with geographic area, heating system, number of family members, family composition, year of construction, electric water heater and electric underfloor heating have been established. The overall result of the analyses is nevertheless that variance in residential electricity consumption cannot be fully explained by independent variables related to household and building characteristics alone. As for the methodological approach, the results further suggest that methods for statistical analysis of variance are of considerable value in indentifying key indicators for policy update and development.

  13. Energy efficiency to reduce residential electricity and natural gas use under climate change.

    Science.gov (United States)

    Reyna, Janet L; Chester, Mikhail V

    2017-05-15

    Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.

  14. Electric heat-pumps in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    1983-03-01

    Since the end of 1979 every other day an electrically operated heat-pump has started operation in Berlin (West). Pros and cons of heat-pumps are a much discussed subject. But what is the opinion of the user. As it is not known the BEWAG carried out a written customer inquiry in the summer 1982. The aim of the inquiry was to improve the advisory service by means of the answers obtained, to obtain information about the reliability or liability to defects of the heat pump, the mechanism they operate on and to know how big the oil substitution potential is. Customer satisfaction with the heat pumps was a further point of interest.

  15. The performance of residential micro-cogeneration coupled with thermal and electrical storage

    Science.gov (United States)

    Kopf, John

    Over 80% of residential secondary energy consumption in Canada and Ontario is used for space and water heating. The peak electricity demands resulting from residential energy consumption increase the reliance on fossil-fuel generation stations. Distributed energy resources can help to decrease the reliance on central generation stations. Presently, distributed energy resources such as solar photovoltaic, wind and bio-mass generation are subsidized in Ontario. Micro-cogeneration is an emerging technology that can be implemented as a distributed energy resource within residential or commercial buildings. Micro-cogeneration has the potential to reduce a building's energy consumption by simultaneously generating thermal and electrical power on-site. The coupling of a micro-cogeneration device with electrical storage can improve the system's ability to reduce peak electricity demands. The performance potential of micro-cogeneration devices has yet to be fully realized. This research addresses the performance of a residential micro-cogeneration device and it's ability to meet peak occupant electrical loads when coupled with electrical storage. An integrated building energy model was developed of a residential micro-cogeneration system: the house, the micro-cogeneration device, all balance of plant and space heating components, a thermal storage device, an electrical storage device, as well as the occupant electrical and hot water demands. This model simulated the performance of a micro-cogeneration device coupled to an electrical storage system within a Canadian household. A customized controller was created in ESP-r to examine the impact of various system control strategies. The economic performance of the system was assessed from the perspective of a local energy distribution company and an end-user under hypothetical electricity export purchase price scenarios. It was found that with certain control strategies the micro-cogeneration system was able to improve the

  16. Residential gas-fired sorption heat pumps. Test and technology evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Naeslund, M.

    2008-12-15

    Heat pumps may be the next step in gas-fired residential space heating. Together with solar energy it is an option to combine natural gas and renewable energy. Heat pumps for residential space heating are likely to be based on the absorption or adsorption process, i.e. sorption heat pumps. Manufacturers claim that the efficiency could reach 140-160%. The annual efficiency will be lower but it is clear that gas-fired heat pumps can involve an efficiency and technology step equal to the transition from non-condensing gas boilers with atmospheric burners to condensing boilers. This report contains a review of the current sorption gas-fired heat pumps for residential space heating and also the visible development trends. A prototype heat pump has been laboratory tested. Field test results from Germany and the Netherlands are also used for a technology evaluation. The tested heat pump unit combines a small heat pump and a supplementary condensing gas boiler. Field tests show an average annual efficiency of 120% for this prototype design. The manufacturer abandoned the tested design during the project period and the current development concentrates on a heat pump design only comprising the heat pump, although larger. The heat pump development at three manufacturers in Germany indicates a commercial stage around 2010-2011. A fairly high electricity consumption compared to traditional condensing boilers was observed in the tested heat pump. Based on current prices for natural gas and electricity the cost savings were estimated to 12% and 27% for heat pumps with 120% and 150% annual efficiency respectively. There is currently no widespread performance testing procedure useful for annual efficiency calculations of gas-fired heat pumps. The situation seems to be clearer for electric compression heat pumps regarding proposed testing and calculation procedures. A German environmental label exists and gasfired sorption heat pumps are also slightly treated in the Eco-design work

  17. Electric heating guidelines: power smart home; 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    Guidelines, for use by B. C. Hydro, were established for proper planning and design of an electric heating system for residential buildings. The guidebook is divided into five sections: (1) comfort and electric heating systems, (2) contractors` guide to heat loss calculation, (3) imperial heat loss factors, (4) metric heat loss factors, and (5) installation guidelines for electric heating systems. Individual topics discussed include heat loss and the human body, heating systems and comfort, heat loss design, air leakage, and soil conductivity factors. Design considerations and equipment standards were described for the following electric heating systems: electric resistance baseboard systems, forced flow unitary heaters, electric radiant cable in-floor systems, radiant ceiling systems, forced warm air heating systems, furnaces, and heat pumps. 68 tabs., 29 figs.

  18. Configuring a fuel cell based residential combined heat and power system

    Science.gov (United States)

    Ahmed, Shabbir; Papadias, Dionissios D.; Ahluwalia, Rajesh K.

    2013-11-01

    The design and performance of a fuel cell based residential combined heat and power (CHP) system operating on natural gas has been analyzed. The natural gas is first converted to a hydrogen-rich reformate in a steam reformer based fuel processor, and the hydrogen is then electrochemically oxidized in a low temperature polymer electrolyte fuel cell to generate electric power. The heat generated in the fuel cell and the available heat in the exhaust gas is recovered to meet residential needs for hot water and space heating. Two fuel processor configurations have been studied. One of the configurations was explored to quantify the effects of design and operating parameters, which include pressure, temperature, and steam-to-carbon ratio in the fuel processor, and fuel utilization in the fuel cell. The second configuration applied the lessons from the study of the first configuration to increase the CHP efficiency. Results from the two configurations allow a quantitative comparison of the design alternatives. The analyses showed that these systems can operate at electrical efficiencies of ∼46% and combined heat and power efficiencies of ∼90%.

  19. Predicting summer residential electricity demand across the U.S.A using climate information

    Science.gov (United States)

    Sun, X.; Wang, S.; Lall, U.

    2017-12-01

    We developed a Bayesian Hierarchical model to predict monthly residential per capita electricity consumption at the state level across the USA using climate information. The summer period was selected since cooling requirements may be directly associated with electricity use, while for winter a mix of energy sources may be used to meet heating needs. Historical monthly electricity consumption data from 1990 to 2013 were used to build a predictive model with a set of corresponding climate and non-climate covariates. A clustering analysis was performed first to identify groups of states that had similar temporal patterns for the cooling degree days of each state. Then, a partial pooling model was applied to each cluster to assess the sensitivity of monthly per capita residential electricity demand to each predictor (including cooling-degree-days, gross domestic product (GDP) per capita, per capita electricity demand of previous month and previous year, and the residential electricity price). The sensitivity of residential electricity to cooling-degree-days has an identifiable geographic distribution with higher values in northeastern United States.

  20. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  1. Impacts of Water Quality on Residential Water Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Baechler, Michael C.

    2013-11-01

    Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

  2. Residential solar-heating system

    Science.gov (United States)

    1978-01-01

    Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

  3. Regional analysis of residential water heating options: energy use and economics

    Energy Technology Data Exchange (ETDEWEB)

    O' Neal, D.; Carney, J.; Hirst, E.

    1978-10-01

    This report evaluates the energy and direct economic effects of introducing improved electric-water-heating systems to the residential market. These systems are: electric heat pumps offered in 1981, solar systems offered in 1977, and solar systems offered in 1977 with a Federal tax credit in effect from 1977 through 1984. The ORNL residential energy model is used to calculate energy savings by type of fuel for each system in each of the ten Federal regions and for the nation as a whole for each year between 1977 and 2000. Changes in annual fuel bills and capital costs for water heaters are also computed at the same level of detail. Model results suggest that heat-pump water heaters are likely to offer much larger energy and economic benefits than will solar systems, even with tax credits. This is because heat pumps provide about the same savings in electricity for water heating (about half) at a much lower capital cost ($700 to $2000) than do solar systems. However, these results are based on highly uncertain estimates of future performance and cost characteristics for both heat pump and solar systems. The cumulative national energy saving by the year 2000 due to commercialization of heat-pump water heaters in 1981 is estimated to be 1.5 QBtu. Solar-energy benefits are about half this much without tax credits and two-thirds as much with tax credits. The net economic benefit to households of heat-pump water heaters (present worth of fuel bill reductions less the present worth of extra costs for more-efficient systems) is estimated to be $640 million. Again, the solar benefits are much less.

  4. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  5. Unleashing Flexibility from Electric Boilers and Heat Pumps in Danish Residential Distribution Network

    DEFF Research Database (Denmark)

    Sinha, Rakesh; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2018-01-01

    and thereby improving its techno-economic efficiency. The data used for the evaluation are also from the real household sites in Denmark provided by the district heating utility. Focus is on the low-voltage grid, and that’s very relevant since many doesn’t expect any flexibility from that voltage level. Study...... this model is compared to responses from an average model of the hot water storage tank to evaluate the benefit of the more detailed model. Finally, analysis on consumption patterns of electrical and thermal loads in residential buildings in Northern Jutland, Denmark, are used for analysis of the system...... and use of thermal units as flexible consumer loads in the low voltage (LV) distribution network grid. The models of EB and HP with storage tank are briefly discussed in relation to the actual control and flexibility based on grid condition and status of storage tank temperature or position...

  6. Quantifying the Flexibility of Residential Electricity Demand in 2050: a Bottom-Up Approach

    OpenAIRE

    van Stiphout, Arne; Engels, Jonas; Guldentops, Dries; Deconinck, Geert

    2015-01-01

    This work presents a new method to quantify the flexibility of automatic demand response applied to residential electricity demand using price elasticities. A stochastic bottom-up model of flexible electricity demand in 2050 is presented. Three types of flexible devices are implemented: electrical heating, electric vehicles and wet appliances. Each house schedules its flexible demand w.r.t. a varying price signal, in order to minimize electricity cost. Own- and cross-price elasticities are ob...

  7. A hybrid society model for simulating residential electricity consumption

    International Nuclear Information System (INIS)

    Xu, Minjie; Hu, Zhaoguang; Wu, Junyong; Zhou, Yuhui

    2008-01-01

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  8. A hybrid society model for simulating residential electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Minjie [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China); State Power Economic Research Institute, Beijing (China); Hu, Zhaoguang [State Power Economic Research Institute, Beijing (China); Wu, Junyong; Zhou, Yuhui [School of Electrical Engineering, Beijing Jiaotong University, Beijing (China)

    2008-12-15

    In this paper, a hybrid social model of econometric model and social influence model is proposed for evaluating the influence of pricing policy and public education policy on residential habit of electricity using in power resources management. And, a hybrid society simulation platform based on the proposed model, called residential electricity consumption multi-agent systems (RECMAS), is designed for simulating residential electricity consumption by multi-agent system. RECMAS is composed of consumer agent, power supplier agent, and policy maker agent. It provides the policy makers with a useful tool to evaluate power price policies and public education campaigns in different scenarios. According to an influenced diffusion mechanism, RECMAS can simulate the residential electricity demand-supply chain and analyze impacts of the factors on residential electricity consumption. Finally, the proposed method is used to simulate urban residential electricity consumption in China. (author)

  9. Exploring utility organization electricity generation, residential electricity consumption, and energy efficiency: A climatic approach

    International Nuclear Information System (INIS)

    Craig, Christopher A.; Feng, Song

    2017-01-01

    Highlights: • Study examined impact of electricity fuel sources and consumption on emissions. • 97.2% of variability in emissions explained by coal and residential electricity use. • Increasing cooling degree days significantly related to increased electricity use. • Effectiveness of state-level energy efficiency programs showed mixed results. - Abstract: This study examined the impact of electricity generation by fuel source type and electricity consumption on carbon emissions to assess the role of climatic variability and energy efficiency (EE) in the United States. Despite high levels of greenhouse gas emissions, residential electricity consumption continues to increase in the United States and fossil fuels are the primary fuel source of electricity generation. 97.2% of the variability in carbon emissions in the electricity industry was explained by electricity generation from coal and residential electricity consumption. The relationships between residential electricity consumption, short-term climatic variability, long-term climatic trends, short-term reduction in electricity from EE programs, and long-term trends in EE programs was examined. This is the first study of its nature to examine these relationships across the 48 contiguous United States. Inter-year and long-term trends in cooling degree days, or days above a baseline temperature, were the primary climatic drivers of residential electricity consumption. Cooling degree days increased across the majority of the United States during the study period, and shared a positive relationship with residential electricity consumption when findings were significant. The majority of electricity reduction from EE programs was negatively related to residential electricity consumption where findings were significant. However, the trend across the majority of states was a decrease in electricity reduction from EE while residential electricity consumption increased. States that successfully reduced consumption

  10. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  11. Smart electric storage heating and potential for residential demand response

    OpenAIRE

    Darby, S

    2017-01-01

    Low-carbon transition plans for temperate and sub-polar regions typically involve some electrification of space heating. This poses challenges to electricity system operation and market design, as it increases overall demand and alters the temporal patterns of that demand. One response to the challenge is to ‘smarten’ electrical heating, enabling it to respond to network conditions by storing energy at times of plentiful supply, releasing it in response to customer demands and offering rapid-...

  12. Modelling and forecasting Turkish residential electricity demand

    International Nuclear Information System (INIS)

    Dilaver, Zafer; Hunt, Lester C

    2011-01-01

    This research investigates the relationship between Turkish residential electricity consumption, household total final consumption expenditure and residential electricity prices by applying the structural time series model to annual data over the period from 1960 to 2008. Household total final consumption expenditure, real energy prices and an underlying energy demand trend are found to be important drivers of Turkish residential electricity demand with the estimated short run and the long run total final consumption expenditure elasticities being 0.38 and 1.57, respectively, and the estimated short run and long run price elasticities being -0.09 and -0.38, respectively. Moreover, the estimated underlying energy demand trend, (which, as far as is known, has not been investigated before for the Turkish residential sector) should be of some benefit to Turkish decision makers in terms of energy planning. It provides information about the impact of past policies, the influence of technical progress, the impacts of changes in consumer behaviour and the effects of changes in economic structure. Furthermore, based on the estimated equation, and different forecast assumptions, it is predicted that Turkish residential electricity demand will be somewhere between 48 and 80 TWh by 2020 compared to 40 TWh in 2008. - Research highlights: → Estimated short run and long run expenditure elasticities of 0.38 and 1.57, respectively. → Estimated short run and long run price elasticities of -0.09 and -0.38, respectively. → Estimated UEDT has increasing (i.e. energy using) and decreasing (i.e. energy saving) periods. → Predicted Turkish residential electricity demand between 48 and 80 TWh in 2020.

  13. Control characteristics and heating performance analysis of automatic thermostatic valves for radiant slab heating system in residential apartments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byung-Cheon [Department of Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea); Song, Jae-Yeob [Graduate School, Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea)

    2010-04-15

    Computer simulations and experiments are carried out to research the control characteristics and heating performances for a radiant slab heating system with automatic thermostatic valves in residential apartments. An electrical equivalent R-C circuit is applied to analyze the unsteady heat transfer in the house. In addition, the radiant heat transfer between slabs, ceilings and walls in the room is evaluated by enclosure analysis method. Results of heating performance and control characteristics were determined from control methods such as automatic thermostatic valves, room air temperature-sensing method, water-temperature-sensing method, proportional control method, and On-Off control method. (author)

  14. Modelling residential electricity demand in the GCC countries

    International Nuclear Information System (INIS)

    Atalla, Tarek N.; Hunt, Lester C.

    2016-01-01

    This paper aims at understanding the drivers of residential electricity demand in the Gulf Cooperation Council countries by applying the structural time series model. In addition to the economic variables of GDP and real electricity prices, the model accounts for population, weather, and a stochastic underlying energy demand trend as a proxy for efficiency and human behaviour. The resulting income and price elasticities are informative for policy makers given the paucity of previous estimates for a region with particular political structures and economies subject to large shocks. In particular, the estimates allow for a sound assessment of the impact of energy-related policies suggesting that if policy makers in the region wish to curtail future residential electricity consumption they would need to improve the efficiency of appliances and increase energy using awareness of consumers, possibly by education and marketing campaigns. Moreover, even if prices were raised the impact on curbing residential electricity growth in the region is likely to be very small given the low estimated price elasticities—unless, that is, prices were raised so high that expenditure on electricity becomes such a large proportion of income that the price elasticities increase (in absolute terms). - Highlights: • Residential electricity demand for Bahrain, Kuwait, Oman, and Saudi Arabia • Estimated residential electricity demand relationships using STSM/UEDT approach • LR income and price elasticities from 0.43 to 0.71 and − 0.16 to zero respectively • Impact CDD elasticities from 0.2 to 0.7 • Estimated UEDTs suggest exogenous electricity using behaviour.

  15. Evaluating the energy and CO2 emissions impacts of shifts in residential water heating in the United States

    International Nuclear Information System (INIS)

    Sanders, Kelly T.; Webber, Michael E.

    2015-01-01

    Water heating represented nearly 13% of 2010 residential energy consumption making it an important target for energy conservation efforts. The objective of this work is to identify spatially-resolved strategies for energy conservation, since little analysis has been done to identify how regional characteristics affect the energy consumed for water heating. We present a first-order thermodynamic analysis, utilizing ab initio calculations and regression methods, to quantify primary energy consumption and CO 2 emissions with regional specificity by considering by considering local electricity mixes, heat rates, solar radiation profiles, heating degrees days, and water heating unit sales for 27 regions of the US. Results suggest that shifting from electric towards natural gas or solar water heating offered primary energy and CO 2 emission reductions in most US regions, but these reductions varied considerably according to regional electricity mix and solar resources. We find that regions that would benefit most from technology transitions, are often least likely to switch due to limited economic incentives. Our results suggest that federal energy factor metrics, which ignore upstream losses in power generation, are insufficient in informing consumers about the energy performance of residential end use appliances. - Highlights: • US energy factor ratings for water heaters ignore upstream losses. • Switching from electric storage water heating reduces CO 2 emissions in most US regions. • Regions with greatest potential for CO 2 avoidance are least likely to shift technologies. • Benefits vary significantly according to climate and regional electricity fuel mix

  16. Heating great residential units with combustion-motor heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Vossen, W

    1982-10-01

    Economic usage of combustion-motor heat pumps requires: reliable technology and delivery of the heat pump; design and operation. The heat pump must be integrated perfectly into the heating system. This contributions is based on a three-year operational experience with over 150 heat pumps used mainly in residential and administrative buildings (plus commercial buildings, swimming pools, sport centres etc.). These are heat pumps operating on the compression principle with natural gas, liquid gas, or fuel oil.

  17. The Sensitivity of Residential Electricity Demand in Indonesia

    Directory of Open Access Journals (Sweden)

    Stranti Nastiti Kusumaningrum

    2018-03-01

    Full Text Available Since 2013, the residential electricity price for High VA (Volt-Ampere households has changed due to changes in pricing policies. This paper analyzes the responsiveness of residential electricity demand to the change in electricity prices and income among two different household groups (Low VA and High VA in 2011 and 2014. Using an electricity consumption model and the Quantile Regression method, the results show that residential electricity demand is price and income inelastic. Income elasticity is lower than price elasticity. Furthermore, the effects on price elasticity also found in the Low VA group, whose rate remained stable. At the same time, evidence proves the impact of the change in pricing policy on income elasticity remains unclear. This result implies that the government has to be more careful in regulating electricity prices for the low VA group, while maintaining economic stability.DOI: 10.15408/sjie.v7i2.6048

  18. ENERGY-EFFICIENT REGIMES FOR HEATING-SUPPLY OF THE RESIDENTIAL BUILDINGS

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2015-01-01

    Full Text Available Rise in comfort and inhabitation safety is one of the main requirements of the general maintenance, reconstruction of the old and construction of the new residential houses. One of the essential factors of it is substitution in the household hot-water preparing sources: from the individual domestic gas  water-heaters to  the common  entire-building hot-water supply at the expense of the centralized heat supply. Extremely erratic hot-water daily consumption by tenants leads to the necessity of sharp increase in central heat-supply level during a few hours of the day, which requires a significant increase of the source heat-power. On that score, the authors propose to direct a significant part (up to 50 % of the centralized heating and ventilation heat power-consumption to the hot water preparation during the period of short-term hot water consumption peak.Substitution  of  the  individual  domestic  gas  water-heaters  with  the  common  entirebuilding hot-water supply releases a huge amount of natural gas which can be utilized not only for production of the necessary heat power but as well for electric power producing. This substitution is especially advantageous if heat-power is delivered to the residential area from a НРС where significant part of heat especially in a relatively warm season of the year is thrown out into the air. The content of the article is based on several patents received earlier.

  19. Market Potential for Residential Biomass Heating Equipment: Stochastic and Econometric Assessments

    OpenAIRE

    Adee Athiyaman

    2015-01-01

    This paper provides estimates of market potential for biomass-residential-heating equipment in the US: that is, the greatest amount of biomass-residential-heating equipment that can be sold by the industry. The author's analysis is limited to biomass equipment used most to heat the housing unit. Assuming that households equipped with 10+ year old primary heating devices will replace rather than repair the devices he predicts that approximately 1.4 million units of residential home heating equ...

  20. Engineering economic assessment of residential wood heating in NY

    Science.gov (United States)

    We provide insight into the recent resurgence in residential wood heating in New York by: (i) examining the lifetime costs of outdoor wood hydronic heaters (OWHHs) and other whole-house residential wood heat devices,(ii) comparing these lifetime costs with those of competing tech...

  1. Modeling and optimization of a heat-pump-assisted high temperature proton exchange membrane fuel cell micro-combined-heat-and-power system for residential applications

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Kær, Søren Knudsen; Nielsen, Mads Pagh

    2015-01-01

    In this study a micro-combined-heat-and-power (micro-CHP) system is coupled to a vapor-compression heat pump to fulfill the residential needs for heating (space heating and water heating) and electricity in detached single-family households in Denmark. Such a combination is assumed to be attractive...... for application, since both fuel cell technology and electric heat pumps are found to be two of the most efficient technologies for generation/conversion of useful energy. The micro-CHP system is fueled with natural gas and includes a fuel cell stack, a fuel processor and other auxiliary components. The micro......-CHP system assumes heat-led operation, to avoid dumping of heat and the use of complicated thermal energy storage. The overall system is grid-interconnected to allow importing and exporting of electricity as necessary. In this study emphasis is given on the operational characterization of the system...

  2. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed [GE Global Research Center, Niskayuna, NY (United States)

    2015-10-27

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

  3. Break-Even Cost for Residential Solar Water Heating in the United States: Key Drivers and Sensitivities

    Energy Technology Data Exchange (ETDEWEB)

    Cassard, H.; Denholm, P.; Ong, S.

    2011-02-01

    This paper examines the break-even cost for residential rooftop solar water heating (SWH) technology, defined as the point where the cost of the energy saved with a SWH system equals the cost of a conventional heating fuel purchased from the grid (either electricity or natural gas). We examine the break-even cost for the largest 1,000 electric and natural gas utilities serving residential customers in the United States as of 2008. Currently, the break-even cost of SWH in the United States varies by more than a factor of five for both electricity and natural gas, despite a much smaller variation in the amount of energy saved by the systems (a factor of approximately one and a half). The break-even price for natural gas is lower than that for electricity due to a lower fuel cost. We also consider the relationship between SWH price and solar fraction and examine the key drivers behind break-even costs. Overall, the key drivers of the break-even cost of SWH are a combination of fuel price, local incentives, and technical factors including the solar resource location, system size, and hot water draw.

  4. SOME FEATURES OF THE POWER SUPPLY OF RESIDENTIAL BUILDINGS DURING THE HEATING SEASON

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available A large proportion of consumption of different types of energy by the residential sector, especially in the heating period, makes the energy efficiency of buildings without considering the loss of fuel with a significant reduction in hourly load on the generators, especially at night, already insufficient for real energy savings. Therefore in Belarus, in order to attract the consumer, electricity tariff for heating at night hours (from 11 p.m. to 6.00 a.m. is three times cheaper than at any other time. Significant increase of the electricity consumption of at night could be achieved by using heat accumulators for heating and hot water supply to the residential sector. Particularly effective are water accumulators of heat and accumulators of underfloor heating that enable to use a coolant with a temperature of 40 оC and to increase the useful supply of heat. The use of heat accumulators for daily heating, ventilation and hot water supply of buildings significantly reduces the cost of creating the infrastructure of the territory under construction by eliminating the necessity of running the distribution network of heat or gas supply. The use of the heat accumulators is necessary due to the increase of the time-weighted average outdoor temperature. The mentioned increase in the City of Minsk in the heating season is of about 0.1 °C per year in average, and as for the last 20 years, the increase has led to a reduction of the required heat load on the premises by about 10 %. Research and project work on choosing the most effective options for the arrangement and use the heat accumulators in buildings of the various functions ought to be fulfilled in order to make the application of heat accumulators successful. In this respect civil and power engineers as well as operators should work together so to determine the chronological, technical and economic conditions of charging and use of heat accumulators.

  5. Evolution of residential electricity demand by end-use in Quebec 1979-1989: A conditional demand analysis

    International Nuclear Information System (INIS)

    Lafrance, G.; Perron, D.

    1994-01-01

    Some of the main conclusions are presented from a temporal analysis of three large-scale electricity demand surveys (1979, 1984, and 1989) for the Quebec residential sector. A regression method called conditional demand analysis was used. The study allows a number of conclusions about certain electricity consumption trends by end-uses from 1979 to 1989 by household type and by vintage category. For example, the results indicate that decreasing electricity consumption between 1979 and 1984 for a typical dwelling equipped with electric space heating was mainly related to a large decline in net heating consumption. Overall, the results suggest that some permanent energy savings have been realized by a typical household equipped with an electric heating system due to improvements in standards and changes in customer behavior. These energy savings were partly offset by increased electricity consumption from the purchase of new appliances and an increase in the demand for hot water. 7 refs., 1 fig., 8 tabs

  6. Estimating elasticity for residential electricity demand in China.

    Science.gov (United States)

    Shi, G; Zheng, X; Song, F

    2012-01-01

    Residential demand for electricity is estimated for China using a unique household level dataset. Household electricity demand is specified as a function of local electricity price, household income, and a number of social-economic variables at household level. We find that the residential demand for electricity responds rather sensitively to its own price in China, which implies that there is significant potential to use the price instrument to conserve electricity consumption. Electricity elasticities across different heterogeneous household groups (e.g., rich versus poor and rural versus urban) are also estimated. The results show that the high income group is more price elastic than the low income group, while rural families are more price elastic than urban families. These results have important policy implications for designing an increasing block tariff.

  7. The analysis of Taiwan's residential electricity demand under the electricity tariff policy

    Science.gov (United States)

    Chen, Po-Jui

    In October 2013, the Taiwan Power Company (Taipower), the monopolized state utility service in Taiwan, implemented an electricity tariff adjustment policy to reduce residential electricity demand. Using bi-monthly billing data from 6,932 electricity consumers, this study examine how consumers respond to an increase in electricity prices. This study employs an empirical approach that takes advantage of quasi-random variation over a period of time when household bills were affected by a change in electricity price. The study found that this price increase caused a 1.78% decline in residential electricity consumption, implying a price elasticity of -0.19 for summer-season months and -0.15 for non-summer-season months. The demand for electricity is therefore relatively inelastic, likely because it is hard for people to change their electricity consumption behavior in the short-term. The results of this study highlight that demand-side management cannot be the only lever used to address Taiwan's forecasted decrease in electricity supply.

  8. Energy saving analysis on mine-water source heat pump in a residential district of Henan province, central China

    Science.gov (United States)

    Wang, Hong; Duan, Huanlin; Chen, Aidong

    2018-02-01

    In this paper, the mine-water source heat pump system is proposed in residential buildings of a mining community. The coefficient of performance (COP) and the efficiency of exergy are analyzed. The results show that the COP and exergy efficiency of the mine-water source heat pump are improved, the exergy efficiency of mine-water source heat pump is more than 10% higher than that of the air source heat pump.The electric power conservation measure of “peak load shifting” is also emphasized in this article. It shows that itis a very considerable cost in the electric saving by adopting the trough period electricity to produce hot water. Due to the proper temperature of mine water, the mine-watersource heat pump unit is more efficient and stable in performance, which further shows the advantage of mine-water source heat pump in energy saving and environmental protection. It provides reference to the design of similar heat pump system as well.

  9. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  10. Energy in the residential building. Electricity, heat, e-mobility. 2. rev. and enl. ed.; Energie im Wohngebaeude. Strom, Waerme, E-Mobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzburger, Heiko

    2017-11-01

    Photovoltaics, heat pumps and fuel cells offer enormous potential for sustainable energy supply in residential buildings. Solar thermal energy and wood-fired boilers also play an important role in refurbishment. Due to the wide range of possible combinations, the wishes of building owners and homeowners for an ecologically and economically individually adapted energy concept can be fulfilled accurately. This book provides you with a holistic approach to the residential building and its supply of electricity, heat and water. All processes that play a role in the house's energy consumption are examined in their entirety for their potentials and potential savings. The author analyses and describes in detail the resources of buildings and their surroundings - and how they can be used for a truly independent supply. The focus is on reducing energy consumption and costs, the generation and supply of energy from renewable sources and energy storage - considered in new construction and modernisation. The supply of water is also dealt with if it touches on energy issues. The author draws attention to standards and regulations and gives practical advice for planning and installation. The focus is on the so-called sector coupling: electricity from the sun, wind and hydrogen is used to supply electrical consumers in the home, charging technology for electric vehicles, hot water and heating. The time of the boilers and combustion engines has elapsed. Clean electricity and digital controls - power and intelligence - determine the regenerative building technology. [German] Photovoltaik, Waermepumpen und Brennstoffzellen bieten enormes Potenzial, die Energieversorgung im Wohngebaeude nachhaltig zu gestalten. In der Sanierung spielen auch Solarthermie und Holzfeuerungen eine wichtige Rolle. Aufgrund der vielfaeltigen Kombinationsmoeglichkeiten lassen sich die Wuensche der Bauherren und Hausbesitzer nach einem oekologisch und oekonomisch individuell angepassten Energiekonzept

  11. Michigan residential heating oil and propane price survey: 1995-1996 heating season. Final report

    International Nuclear Information System (INIS)

    Moriarty, C.

    1996-05-01

    This report summarizes the results of a survey of residential No. 2 distillate fuel (home heating oil) and liquefied petroleum gas (propane) prices over the 1995--1996 heating season in Michigan. The Michigan's Public Service Commission (MPSC) conducted the survey under a cooperative agreement with the US Department of Energy's (DOE) Energy Information Administration (EIA). This survey was funded in part by a grant from the DOE. From October 1995 through March 1996, the MPSC surveyed participating distributors by telephone for current residential retail home heating oil and propane prices. The MPSC transmitted the data via a computer modem to the EIA using the Petroleum Electronic Data Reporting Option (PEDRO). Survey results were published in aggregate on the MPSC World Wide Web site at http://ermisweb.state.mi.us/shopp. The page was updated with both residential and wholesale prices immediately following the transmission of the data to the EIA. The EIA constructed the survey using a sample of Michigan home heating oil and propane retailers. The sample accounts for different sales volumes, geographic location, and sources of primary supply

  12. 75 FR 14368 - Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public...

    Science.gov (United States)

    2010-03-25

    ... Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public Meeting and Availability... conservation standards for residential central air conditioners and heat pumps; the analytical framework..., Mailstop EE-2J, Public Meeting for Residential Central Air Conditioners and Heat Pumps, EERE-2008-BT- STD...

  13. ON REASONABLE ESTIMATE OF ENERGY PERFORMANCE OF THE RESIDENTIAL BUILDINGS SUSTENANCE WITH CENTRALIZED HEAT-SUPPLY SYSTEM

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2016-01-01

    the period from 2006 to 2013, by virtue of the heat-supply schemes optimization and modernizing the heating systems using valuable (200–300 $US per 1 m though hugely effective preliminary coated pipes, the economy reached 2,7 MIO tons of fuel equivalent. Heat-energy general losses in municipal services of Belarus in March 2014 amounted up 17 %, whilst in 2001 they were at the level of 26 % and in 1990 – more than 30 %. With a glance to multi-staging and multifactorial nature (electricity, heat and water supply of the residential sector energy saving, the reasonable estimate of the residential buildings sustenance energy efficiency should be performed in tons of fuel equivalent in a unit of time.

  14. Lifestyle factors in U.S. residential electricity consumption

    International Nuclear Information System (INIS)

    Sanquist, Thomas F.; Orr, Heather; Shui Bin; Bittner, Alvah C.

    2012-01-01

    A multivariate statistical approach to lifestyle analysis of residential electricity consumption is described and illustrated. Factor analysis of selected variables from the 2005 U.S. Residential Energy Consumption Survey (RECS) identified five lifestyle factors reflecting social and behavioral patterns associated with air conditioning, laundry usage, personal computer usage, climate zone of residence, and TV use. These factors were also estimated for 2001 RECS data. Multiple regression analysis using the lifestyle factors yields solutions accounting for approximately 40% of the variance in electricity consumption for both years. By adding the household and market characteristics of income, local electricity price and access to natural gas, variance accounted for is increased to approximately 54%. Income contributed ∼1% unique variance to the models, indicating that lifestyle factors reflecting social and behavioral patterns better account for consumption differences than income. Geographic segmentation of factor scores shows distinct clusters of consumption and lifestyle factors, particularly in suburban locations. The implications for tailored policy and planning interventions are discussed in relation to lifestyle issues. - Highlights: ► Illustrates lifestyle analysis of residential electricity consumption. ► Lifestyle factors based on social and behavioral decisions and equipment use. ► Regression models using lifestyle factors account for 40% of consumption variance. ► Lifestyle factors are stable over time when applied to other data sets. ► Energy reduction opportunities are identified by segmentation analysis.

  15. Estimation of energy efficiency of residential buildings

    Directory of Open Access Journals (Sweden)

    Glushkov Sergey

    2017-01-01

    Full Text Available Increasing energy performance of the residential buildings by means of reducing heat consumption on the heating and ventilation is the last segment in the system of energy resources saving. The first segments in the energy saving process are heat producing and transportation over the main lines and outside distribution networks. In the period from 2006 to 2013. by means of the heat-supply schemes optimization and modernization of the heating systems. using expensive (200–300 $US per 1 m though hugely effective preliminary coated pipes. the economy reached 2.7 mln tons of fuel equivalent. Considering the multi-stage and multifactorial nature (electricity. heat and water supply of the residential sector energy saving. the reasonable estimate of the efficiency of the saving of residential buildings energy should be performed in tons of fuel equivalent per unit of time.

  16. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  17. The Relationship between Residential Electricity Consumption and Income: A Piecewise Linear Model with Panel Data

    Directory of Open Access Journals (Sweden)

    Yanan Liu

    2016-10-01

    Full Text Available There are many uncertainties and risks in residential electricity consumption associated with economic development. Knowledge of the relationship between residential electricity consumption and its key determinant—income—is important to the sustainable development of the electric power industry. Using panel data from 30 provinces for the 1995–2012 period, this study investigates how residential electricity consumption changes as incomes increase in China. Previous studies typically used linear or quadratic double-logarithmic models imposing ex ante restrictions on the indistinct relationship between residential electricity consumption and income. Contrary to those models, we employed a reduced piecewise linear model that is self-adaptive and highly flexible and circumvents the problem of “prior restrictions”. Robust tests of different segment specifications and regression methods are performed to ensure the validity of the research. The results provide strong evidence that the income elasticity was approximately one, and it remained stable throughout the estimation period. The income threshold at which residential electricity consumption automatically remains stable or slows has not been reached. To ensure the sustainable development of the electric power industry, introducing higher energy efficiency standards for electrical appliances and improving income levels are vital. Government should also emphasize electricity conservation in the industrial sector rather than in residential sector.

  18. Environmental and energy efficiency evaluation of residential gas and heat pump heating

    International Nuclear Information System (INIS)

    Ganji, A.R.

    1993-01-01

    Energy efficiency and source air pollutant emission factors of gas heaters, gas engine heat pumps, and electric heat pumps for domestic heating have been evaluated and compared. The analysis shows that with the present state of technology, gas engine heat pumps have the highest energy efficiency followed by electric heat pumps and then gas heaters. Electric heat pumps produce more than twice as much NO x , and comparable CO 2 and CO per unit of useful heating energy compared to natural gas heaters. CO production per unit of useful heating energy from gas engine heat pumps without any emission control is substantially higher than electric heat pumps and natural gas heaters. NO x production per unit of useful heating energy from natural gas engine heat pumps (using lean burn technology) without any emission control is about the same as effective NO x production from electric heat pumps. Gas engine heat pumps produce about one-half CO 2 compared to electric heat pumps

  19. Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

    Science.gov (United States)

    1978-01-01

    A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  20. Residential electricity demand in Singapore

    International Nuclear Information System (INIS)

    Ang, B.W.; Goh, T.N.; Liu, X.Q.

    1992-01-01

    Residential electricity consumption in Singapore increased at a rate of 8.8% per year between 1972 and 1990. Estimates of the long-run income and price elasticities are 1.0 and -0.35, respectively. The energy-conservation campaigns that have been launched are found to have marginal effects on consumption. A statistical analysis shows that the consumption is sensitive to small changes in climatic variables, particularly the temperature, which is closely linked to the growing diffusion of electric appliances for environmental controls. There has been a temporal increase in the ownership levels of appliances associated with increasing household incomes. However, other factors were involved since the ownership levels would also increase over time after the elimination of the income effect. A large part of the future growth in electricity demand will arise from the growing need for air-conditioning, which will lead to increasingly large seasonal variations in electricity use. (author)

  1. 77 FR 2743 - Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair-“Power Up”

    Science.gov (United States)

    2012-01-19

    ...] Recovery Directorate Fact Sheet 9580.213, Residential Electrical Meter Repair--``Power Up'' AGENCY: Federal..., Residential Electrical Meter Repair--``Power Up.'' DATES: Comments must be received by February 21, 2012... authority, FEMA may fund the repair of residential electrical meters damaged in a major disaster or...

  2. Expanding photovoltaic penetration with residential distributed generation from hybrid solar photovoltaic and combined heat and power systems

    International Nuclear Information System (INIS)

    Pearce, J.M.

    2009-01-01

    The recent development of small scale combined heat and power (CHP) systems has provided the opportunity for in-house power backup of residential-scale photovoltaic (PV) arrays. This paper investigates the potential of deploying a distributed network of PV + CHP hybrid systems in order to increase the PV penetration level in the U.S. The temporal distribution of solar flux, electrical and heating requirements for representative U.S. single family residences were analyzed and the results clearly show that hybridizing CHP with PV can enable additional PV deployment above what is possible with a conventional centralized electric generation system. The technical evolution of such PV + CHP hybrid systems was developed from the present (near market) technology through four generations, which enable high utilization rates of both PV-generated electricity and CHP-generated heat. A method to determine the maximum percent of PV-generated electricity on the grid without energy storage was derived and applied to an example area. The results show that a PV + CHP hybrid system not only has the potential to radically reduce energy waste in the status quo electrical and heating systems, but it also enables the share of solar PV to be expanded by about a factor of five. (author)

  3. Estimation of urban residential electricity demand in China using household survey data

    International Nuclear Information System (INIS)

    Zhou, Shaojie; Teng, Fei

    2013-01-01

    This paper uses annual urban household survey data of Sichuan Province from 2007 to 2009 to estimate the income and price elasticities of residential electricity demand, along with the effects of lifestyle-related variables. The empirical results show that in the urban area of Sichuan province, the residential electricity demand is price- and income-inelastic, with price and income elasticities ranging from −0.35 to −0.50 and from 0.14 to 0.33, respectively. Such lifestyle-related variables as demographic variables, dwelling size and holdings of home appliances, are also important determinants of residential electricity demand, especially the latter. These results are robust to a variety of sensitivity tests. The research findings imply that urban residential electricity demand continues to increase with the growth of income. The empirical results have important policy implications for the Multistep Electricity Price, which been adopted in some cities and is expected to be promoted nationwide through the installation of energy-efficient home appliances. - Highlights: • We estimate price and income elasticities in China using household survey data. • The current study is the first such study in China at this level. • Both price and income are inelastic. • Behavior factors have important impact on electricity consumption

  4. Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  5. Electricity demand for South Korean residential sector

    International Nuclear Information System (INIS)

    Sa'ad, Suleiman

    2009-01-01

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

  6. Post-evaluation of a ground source heat pump system for residential space heating in Shanghai China

    Science.gov (United States)

    Lei, Y.; Tan, H. W.; Wang, L. Z.

    2017-11-01

    Residents of Southern China are increasingly concerned about the space heating in winter. The chief aim of the present work is to find a cost-effective way for residential space heating in Shanghai, one of the biggest city in south China. Economic and energy efficiency of three residential space heating ways, including ground source heat pump (GSHP), air source heat pump (ASHP) and wall-hung gas boiler (WHGB), are assessed based on Long-term measured data. The results show that the heat consumption of the building is 120 kWh/m2/y during the heating season, and the seasonal energy efficiency ratio (SEER) of the GSHP, ASHP and WHGB systems are 3.27, 2.30, 0.88 respectively. Compared to ASHP and WHGB, energy savings of GSHP during the heating season are 6.2 kgce/(m2.y) and 2.2 kgce/(m2.y), and the payback period of GSHP are 13.3 and 7.6 years respectively. The sensitivity analysis of various factors that affect the payback period is carried out, and the results suggest that SEER is the most critical factor affecting the feasibility of ground source heat pump application, followed by building load factor and energy price factor. These findings of the research have led the author to the conclusion that ground source heat pump for residential space heating in Shanghai is a good alternative, which can achieve significant energy saving benefits, and a good system design and operation management are key factors that can shorten the payback period.

  7. Reducing residential solid fuel combustion through electrified space heating leads to substantial air quality, health and climate benefits in China's Beijing-Tianjin-Hebei region

    Science.gov (United States)

    Yang, J.; Mauzerall, D. L.

    2017-12-01

    During periods of high pollution in winter, household space heating can contribute more than half of PM2.5 concentrations in China's Beijing-Tianjin-Hebei (BTH) region. The majority of rural households and some urban households in the region still heat with small stoves and solid fuels such as raw coal, coal briquettes and biomass. Thus, reducing emissions from residential space heating has become a top priority of the Chinese government's air pollution mitigation plan. Electrified space heating is a promising alternative to solid fuel. However, there is little analysis of the air quality and climate implications of choosing various electrified heating devices and utilizing different electricity sources. Here we conduct an integrated assessment of the air quality, human health and climate implications of various electrified heating scenarios in the BTH region using the Weather Research and Forecasting model with Chemistry. We use the Multi-resolution Emission Inventory for China for the year 2012 as our base case and design two electrification scenarios in which either direct resistance heaters or air source heat pumps are installed to replace all household heating stoves. We initially assume all electrified heating devices use electricity from supercritical coal-fired power plants. We find that installing air source heat pumps reduces CO2 emissions and premature deaths due to PM2.5 pollution more than resistance heaters, relative to the base case. The increased health and climate benefits of heat pumps occur because they have a higher heat conversion efficiency and thus require less electricity for space heating than resistance heaters. We also find that with the same heat pump installation, a hybrid electricity source (40% of the electricity generated from renewable sources and the rest from coal) further reduces both CO2 emissions and premature deaths than using electricity only from coal. Our study demonstrates the air pollution and CO2 mitigation potential and

  8. Electricity consumption in G7 countries: A panel cointegration analysis of residential demand elasticities

    International Nuclear Information System (INIS)

    Narayan, Paresh Kumar; Smyth, Russell; Prasad, Arti

    2007-01-01

    This article applies recently developed panel unit root and panel cointegration techniques to estimate the long-run and short-run income and price elasticities for residential demand for electricity in G7 countries. The panel results indicate that in the long-run residential demand for electricity is price elastic and income inelastic. The study concludes that from an environmental perspective there is potential to use pricing policies in the G7 countries to curtail residential electricity demand, and thus curb carbon emissions, in the long run. (author)

  9. Numerical Model and Experimental Analysis of the Thermal Behavior of Electric Radiant Heating Panels

    Directory of Open Access Journals (Sweden)

    Giovanni Ferrarini

    2018-01-01

    Full Text Available Electric radiant heating panels are frequently selected during the design phase of residential and industrial heating systems, especially for retrofit of existing buildings, as an alternative to other common heating systems, such as radiators or air conditioners. The possibility of saving living and working space and the ease of installation are the main advantages of electric radiant solutions. This paper investigates the thermal performance of a typical electric radiant panel. A climatic room was equipped with temperature sensors and heat flow meters to perform a steady state experimental analysis. For the dynamic behavior, a mathematical model was created and compared to a thermographic measurement procedure. The results showed for the steady state an efficiency of energy transformation close to one, while in a transient thermal regime the time constant to reach the steady state condition was slightly faster than the typical ones of hydronic systems.

  10. Thermal-hydraulic process for cooling, heating and power production with low-grade heat sources in residential sector

    International Nuclear Information System (INIS)

    Borgogno, R.; Mauran, S.; Stitou, D.; Marck, G.

    2017-01-01

    Highlights: • Assessment of solar thermal-hydraulic process for tri-generation application. • Choice of the most suitable working fluid pair (R1234yf/R1233zd). • Evaluation of the global annual performance in Mediterranean climate. • Global annual COP and heat amplification achieving 0.24 and 1.2 respectively. • Global annual performance achieving an electric efficiency of 3.7%. - Abstract: A new process based on thermal-hydraulic conversion actuated by low-grade thermal energy is investigated. Input thermal energy can be provided by the means of solar collectors, as well as other low temperature energy sources. In the following article, “thermo-hydraulic” term refers to a process involving an incompressible fluid used as an intermediate medium to transfer work hydraulically between different thermal operated components or sub-systems. The system aims at providing trigeneration energy features for the residential sector, that is providing heating, cooling and electrical power for meeting the energy needs of domestic houses. This innovative system is made of two dithermal processes (working at two different levels of temperatures) and featuring two different working fluids. The first process is able to directly supply either electrical energy generated by an hydraulic turbine or drives the second process thanks to the incompressible fluid, which is similar to a heat pump effect for heating or cooling purposes. The innovative aspect of this process relies on the use of an hydraulic transfer fluid to transfer the work between each sub-system and therefore simplifying the conversion chain. A model, assuming steady-state operation, is developed to assess the energy performances of different variants of this thermo-hydraulic process with various heat source temperatures (80–110 °C) or heat sinks (0–30 °C), as well as various pairs of working fluids. For instance, in the frame of a single-family home, located in the Mediterranean region, the working

  11. Electricity demand for South Korean residential sector

    Energy Technology Data Exchange (ETDEWEB)

    Sa' ad, Suleiman [Surrey Energy Economics Centre (SEEC), Department of Economics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-12-15

    This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

  12. Residential cogeneration systems: review of the current technology

    International Nuclear Information System (INIS)

    Onovwiona, H.I.; Ugursal, V.I.

    2006-01-01

    There is a growing potential for the use of micro-cogeneration systems in the residential sector because they have the ability to produce both useful thermal energy and electricity from a single source of fuel such as oil or natural gas. In cogeneration systems, the efficiency of energy conversion increases to over 80% as compared to an average of 30-35% for conventional fossil fuel fired electricity generation systems. This increase in energy efficiency can result in lower costs and reduction in greenhouse gas emissions when compared to the conventional methods of generating heat and electricity separately. Cogeneration systems and equipment suitable for residential and small-scale commercial applications like hospitals, hotels or institutional buildings are available, and many new systems are under development. These products are used or aimed for meeting the electrical and thermal demands of a building for space and domestic hot water heating, and potentially, absorption cooling. The aim of this paper is to provide an up-to-date review of the various cogeneration technologies suitable for residential applications. The paper considers the various technologies available and under development for residential, i.e. single-family ( e ) and multi-family (10-30kW t ) applications, with focus on single-family applications. Technologies suitable for residential cogeneration systems include reciprocating internal combustion engine, micro-turbine, fuel cell, and reciprocating external combustion Stirling engine based cogeneration systems. The paper discusses the state of development and the performance, environmental benefits, and costs of these technologies. (author)

  13. Competitivity of biofuels in heating

    International Nuclear Information System (INIS)

    Flyktman, M.

    1996-01-01

    The competitivity of indigenous fuels in heating of residential houses in comparison with imported fuels, and both electricity and district heating, has been studied in this research, ordered by the Finnish Ministry of Trade and Industry. Heating plants of residential house scale (20-1000 kW) have been investigated in the research. Only the new heating plants are included in the investigation. The heat generation calculations concerning the residential heating plants have been made for following indigenous fuels: sod peat, fuel-chips, peat and wood pellets, firewood and straw. In addition to these, the calculations have been made for light fuel-oil, electric heating, district heating and natural gas. The local energy tariffs have to be taken into account in electric heating, district heating and natural gas heating. A calculation model, based on flowsheet calculation, forms the main result of the project. By using the model it is possible to update the competitivity data rapidly. Of all the indigenous fuels, sod peat and fuel-chips appeared to be competitive with electric and district heating costs in nearly all scales investigated. The construction of the heat generation costs of solid indigenous fuels differs remarkably from those of electric and district heating. The main part of the heating costs of wood chips and sod peat is formed of fixed costs; i.e. of investment costs and of the costs of heating and control work. The energy costs are the highest costs items in electric an district heating, as well as in the oil heating. It is possible to improve the competitivity of biofuels by developing cheaper boilers and fuel processing and storage devices

  14. Modeling of Monthly Residential and Commercial Electricity Consumption Using Nonlinear Seasonal Models—The Case of Hong Kong

    Directory of Open Access Journals (Sweden)

    Wai-Ming To

    2017-06-01

    Full Text Available Accurate modeling and forecasting monthly electricity consumption are the keys to optimizing energy management and planning. This paper examines the seasonal characteristics of electricity consumption in Hong Kong—a subtropical city with 7 million people. Using the data from January 1970 to December 2014, two novel nonlinear seasonal models for electricity consumption in the residential and commercial sectors were obtained. The models show that the city’s monthly residential and commercial electricity consumption patterns have different seasonal variations. Specifically, monthly residential electricity consumption (mainly for appliances and cooling in summer has a quadratic relationship with monthly mean air temperature, while monthly commercial electricity consumption has a linear relationship with monthly mean air temperature. The nonlinear seasonal models were used to predict residential and commercial electricity consumption for the period January 2015–December 2016. The correlations between the predicted and actual values were 0.976 for residential electricity consumption and 0.962 for commercial electricity consumption, respectively. The root mean square percentage errors for the predicted monthly residential and commercial electricity consumption were 7.0% and 6.5%, respectively. The new nonlinear seasonal models can be applied to other subtropical urban areas, and recommendations on the reduction of commercial electricity consumption are given.

  15. Heat Pump Water Heater Technology: Experiences of Residential Consumers and Utilities

    Energy Technology Data Exchange (ETDEWEB)

    Ashdown, BG

    2004-08-04

    This paper presents a case study of the residential heat pump water heater (HPWH) market. Its principal purpose is to evaluate the extent to which the HPWH will penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to compare readiness and to factor attributes of market demand back into product design. This study is a rapid prototype analysis rather than a detailed case analysis. For this reason, primary data collection was limited and reliance on secondary sources was extensive. Despite having met its technical goals and having been on the market for twenty years, the HPWH has had virtually no impact on contributing to the nation's water heating. In some cases, HPWH reliability and quality control are well below market expectations, and early units developed a reputation for unreliability, especially when measured against conventional water heaters. In addition to reliability problems, first costs of HPWH units can be three to five times higher than conventional units. Without a solid, well-managed business plan, most consumers will not be drawn to this product. This is unfortunate. Despite its higher first costs, efficiency of an HPWH is double that of a conventional water heater. The HPWH also offers an attractive payback period of two to five years, depending on hot water usage. On a strict life-cycle basis it supplies hot water very cost effectively. Water heating accounts for 17% of the nation's residential consumption of electricity (see chart at left)--water heating is second only to space heating in total residential energy use. Simple arithmetic suggests that this figure could be reduced to the extent HPWH technology displaces conventional water heating. In addition, the HPWH offers other

  16. Energy Efficiency and Sustainability Evaluation of Space and Water Heating in Urban Residential Buildings of the Hot Summer and Cold Winter Zone in China

    Directory of Open Access Journals (Sweden)

    Xiao Chen

    2016-09-01

    Full Text Available With the urbanization process of the hot summer and cold winter (HSCW zone in China, the energy consumption of space and water heating in urban residential buildings of the HSCW zone has increased rapidly. This study presents the energy efficiency and sustainability evaluation of various ways of space and water heating taking 10 typical cities in the HSCW zone as research cases. Two indicators, primary energy efficiency (PEE and sustainability index based on exergy efficiency, are adopted to perform the evaluation. Models for the energy and total exergy efficiencies of various space and water heating equipment/systems are developed. The evaluation results indicate that common uses of electricity for space and water heating are the most unsustainable ways of space and water heating. In terms of PEE and sustainability index, air-source heat pumps for space and water heating are suitable for the HSCW zone. The PEE and sustainability index of solar water heaters with auxiliary electric heaters are greatly influenced by local solar resources. Air-source heat pump assisted solar hot water systems are the most sustainable among all water heating equipment/systems investigated in this study. Our works suggest the key potential for improving the energy efficiency and the sustainability of space and water heating in urban residential buildings of the HSCW zone.

  17. Economic aspects of possible residential heating conservation

    Energy Technology Data Exchange (ETDEWEB)

    Hopkowicz, M.; Szul, A. [Technical Univ., Cracow (Poland)

    1995-12-31

    The paper presents methods of evaluation of energy and economy related effects of different actions aimed at conservation in residential buildings. It identifies also the method of selecting the most effective way of distribution funds assigned to weatherization as well as necessary improvements to be implemented within the heating node and the internal heating system of the building. The analysis of data gathered for four 11-stories high residential buildings of {open_quotes}Zeran{close_quotes} type being subject of the Conservation Demonstrative Project, included a differentiated scope of weatherization efforts and various actions aimed at system upgrading. Basing upon the discussion of the split of heat losses in a building as well as the established energy savings for numerous options of upgrading works, the main problem has been defined. It consists in optimal distribution of financial means for the discussed measures if the total amount of funds assigned for modifications is defined. The method based upon the principle of relative increments has been suggested. The economical and energy specifications of the building and its components, required for this method have also been elaborated. The application of this method allowed to define the suggested optimal scope of actions within the entire fund assigned for the comprehensive weatherization.

  18. Residential electricity consumption in Portugal: Findings from top-down and bottom-up models

    International Nuclear Information System (INIS)

    Wiesmann, Daniel; Lima Azevedo, Ines; Ferrao, Paulo; Fernandez, John E.

    2011-01-01

    An econometric study of the Portuguese residential electricity consumption is presented, with a focus on the influence of dwelling characteristics on consumption. The relationship between the dwelling and household characteristics on per capita residential electricity consumption is estimated at two different scales, involving two distinct databases: the first includes data at the municipality level for 2001, the second is the most recent Portuguese consumer expenditure survey that was collected in 2005 and 2006. The results of the analysis at both scales are consistent and indicate that household and dwelling characteristics have a significant influence on residential electricity consumption. Our results show that in Portugal the direct effect of income on electricity consumption is low and becomes smaller when more relevant control variables are included in the analysis. Future demand of electricity in Portugal will be significantly influenced by trends in socioeconomic factors as well as changes in the building stock. These trends should be taken in consideration in the formulation of policy measures to reduce electricity consumption. - Research highlights: → Econometric study of per capita residential electricity consumption in Portugal. → Comparing models at two levels of aggregation: by municipality and by household. → Using proxies for the dwelling characteristics on the municipality level. → Results from both scales are consistent. → Income elasticity is low and the influence of dwelling characteristics is significant.

  19. Residential electricity consumption in Portugal: Findings from top-down and bottom-up models

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, Daniel, E-mail: daniel.wiesmann@ist.utl.p [Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais 1, 1049-001 Lisbon (Portugal); Lima Azevedo, Ines [Department of Engineering and Public Policy, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States); Ferrao, Paulo [Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais 1, 1049-001 Lisbon (Portugal); Fernandez, John E. [Department of Architecture, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2011-05-15

    An econometric study of the Portuguese residential electricity consumption is presented, with a focus on the influence of dwelling characteristics on consumption. The relationship between the dwelling and household characteristics on per capita residential electricity consumption is estimated at two different scales, involving two distinct databases: the first includes data at the municipality level for 2001, the second is the most recent Portuguese consumer expenditure survey that was collected in 2005 and 2006. The results of the analysis at both scales are consistent and indicate that household and dwelling characteristics have a significant influence on residential electricity consumption. Our results show that in Portugal the direct effect of income on electricity consumption is low and becomes smaller when more relevant control variables are included in the analysis. Future demand of electricity in Portugal will be significantly influenced by trends in socioeconomic factors as well as changes in the building stock. These trends should be taken in consideration in the formulation of policy measures to reduce electricity consumption. - Research highlights: {yields} Econometric study of per capita residential electricity consumption in Portugal. {yields} Comparing models at two levels of aggregation: by municipality and by household. {yields} Using proxies for the dwelling characteristics on the municipality level. {yields} Results from both scales are consistent. {yields} Income elasticity is low and the influence of dwelling characteristics is significant.

  20. Impact of Uncoordinated Plug-in Electric Vehicle Charging on Residential Power Demand

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-22

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  1. Impact of uncoordinated plug-in electric vehicle charging on residential power demand

    Science.gov (United States)

    Muratori, Matteo

    2018-03-01

    Electrification of transport offers opportunities to increase energy security, reduce carbon emissions, and improve local air quality. Plug-in electric vehicles (PEVs) are creating new connections between the transportation and electric sectors, and PEV charging will create opportunities and challenges in a system of growing complexity. Here, I use highly resolved models of residential power demand and PEV use to assess the impact of uncoordinated in-home PEV charging on residential power demand. While the increase in aggregate demand might be minimal even for high levels of PEV adoption, uncoordinated PEV charging could significantly change the shape of the aggregate residential demand, with impacts for electricity infrastructure, even at low adoption levels. Clustering effects in vehicle adoption at the local level might lead to high PEV concentrations even if overall adoption remains low, significantly increasing peak demand and requiring upgrades to the electricity distribution infrastructure. This effect is exacerbated when adopting higher in-home power charging.

  2. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  3. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  4. Market-based Demand Response via Residential Plug-in Electric Vehicles in Smart Grids

    OpenAIRE

    Rassaei, Farshad; Soh, Wee-Seng; Chua, Kee-Chaing

    2015-01-01

    Flexibility in power demand, diverse usage patterns and storage capability of plug-in electric vehicles (PEVs) grow the elasticity of residential electricity demand remarkably. This elasticity can be utilized to form the daily aggregated demand profile and/or alter instantaneous demand of a system wherein a large number of residential PEVs share one electricity retailer or an aggregator. In this paper, we propose a demand response (DR) technique to manage vehicle-to-grid (V2G) enabled PEVs' e...

  5. Historical changes and recent energy saving potential of residential heating in Korea

    International Nuclear Information System (INIS)

    Yeo, M.-S.; Yang, I.-H.; Kim, K.-W.

    2003-01-01

    The residential heating method in Korea underwent various phases of development to reach the current system. The first phase was the traditional Ondol (the traditional under-floor heating system in Korea), where the floor was heated by the circulation of hot gas produced by a fire furnace (before the 1950s). The second phase involved the use of the modified anthracite coal Ondol, for which the fire furnace was modified for briquette use (from the early 1950s to the late 1970s). The third phase involved the use of hot water radiant floor heating with embedded tubes (from the late 1970s). This paper presents insights into the problem of current residential heating in Korea and the general aspects of heating energy savings by tracing the history of residential heating in Korea and analyzing related data. The results show that modern apartment buildings with hot water radiant floor heating (the third phase) yield less heat loss due to the tighter envelope, but also yield higher energy consumption than the traditional Ondol heating housing (the first phase). Because of an inefficient system and lack of thermal insulation of the traditional Ondol heating housing, Ondol heating was used to heat occupants sitting directly on the floor, keeping lower room temperature and higher floor surface temperature. So the range of comfortable floor temperature for Korean people is higher and this unique comfort sense is related to energy consumption in modern apartment housing. As a result, several energy saving methods were found such as reducing the total floor heating area or zoning the floor area, receiving continuous heat supply, and installing a delicate control system and metering devices. (author)

  6. Stochastic analysis of residential micro combined heat and power system

    International Nuclear Information System (INIS)

    Karami, H.; Sanjari, M.J.; Gooi, H.B.; Gharehpetian, G.B.; Guerrero, J.M.

    2017-01-01

    Highlights: • Applying colonial competitive algorithm to the problem of optimal dispatching. • Economic modeling of the residential integrated energy system. • Investigating differences of stand-alone and system-connected modes of fuel cell operation. • Considering uncertainty on the electrical load. • The effects of battery capacity and its efficiency on the system is investigated. - Abstract: In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm is adopted to the hybrid energy system scheduling problem and different energy resources are optimally scheduled to have optimal operating cost of hybrid energy system. In order to show the effectiveness of the colonial competitive algorithm, the results are compared with the results of the harmony search algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected to be used effectively in a real hybrid energy system.

  7. The residential dual-energy program of Hydro-Quebec: An economic analysis

    International Nuclear Information System (INIS)

    Bergeron, C.; Bernard, J.-T.

    1991-01-01

    Higher than expected electricity consumption in recent years and increasing objections to capacity expansion on environmental grounds have led Quebec's government-owned electric utility, Hydro-Quebec, to launch an innovative program to reduce peak period residential electric heating demand. When the outside temperature drops below -12 degree C, customers who have opted for the program are charged 10 cents/kWh for their electricity (substantially above the 4.46 cents/kWh paid by normal residential customers) and they are automatically switched to a non-electric heating source, whereas above -12 degree C they pay 2.75 cents/kWh for all uses. A cost benefit analysis of this dual energy program finds that if, as Hydro-Quebec forecasts, 150,000 residential customers were to opt for this program, they would benefit by $19.0 million per year, while the utility and the government would lose $21.6 million and $1.6 million respectively, with a total net loss to Quebec society of $4.25 million a year. 12 refs., 4 figs., 6 tabs

  8. Solid oxide fuel cell systems for residential micro-combined heat and power in the UK: Key economic drivers

    Science.gov (United States)

    Hawkes, Adam; Leach, Matthew

    The ability of combined heat and power (CHP) to meet residential heat and power demands efficiently offers potentially significant financial and environmental advantages over centralised power generation and heat-provision through natural-gas fired boilers. A solid oxide fuel cell (SOFC) can operate at high overall efficiencies (heat and power) of 80-90%, offering an improvement over centralised generation, which is often unable to utilise waste heat. This paper applies an equivalent annual cost (EAC) minimisation model to a residential solid oxide fuel cell CHP system to determine what the driving factors are behind investment in this technology. We explore the performance of a hypothetical SOFC system—representing expectations of near to medium term technology development—under present UK market conditions. We find that households with small to average energy demands do not benefit from installation of a SOFC micro-CHP system, but larger energy demands do benefit under these conditions. However, this result is sensitive to a number of factors including stack capital cost, energy import and export prices, and plant lifetime. The results for small and average dwellings are shown to reverse under an observed change in energy import prices, an increase in electricity export price, a decrease in stack capital costs, or an improvement in stack lifetime.

  9. The residential electricity sector in Denmark: A description of current conditions

    DEFF Research Database (Denmark)

    Kitzing, Lena; Katz, Jonas; Schröder, Sascha Thorsten

    We provide an overview of the current conditions and framework for residential electricity consumption in Denmark. This includes a general overview of the sector, the retail market and the regulatory framework. We describe the regulations currently in place and changes which have been decided...... in the area, which are listed in the Glossary towards the end of the report. We also attach a list and description of the major sources of information and data that can be obtained and downloaded for analysis of the Danish residential electricity sector....

  10. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

  11. TESTING OF REFRIGERANT MIXTURES IN RESIDENTIAL HEAT PUMPS

    Science.gov (United States)

    The report gives results of an investigation of four possibilities for replacing Hydrochlorofluorocarbon-22 (HCFC-22) with the non-ozone-depleting new refrigerants R-407D and R-407C in residential heat pumps. The first and simplest scenario was a retrofit with no hardware modific...

  12. An analysis of representative heating load lines for residential HSPF ratings

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-07-01

    This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28

  13. Residential home heating: The potential for air source heat pump technologies as an alternative to solid and liquid fuels

    International Nuclear Information System (INIS)

    Kelly, J. Andrew; Fu, Miao; Clinch, J. Peter

    2016-01-01

    International commitments on greenhouse gases, renewables and air quality warrant consideration of alternative residential heating technologies. The residential sector in Ireland accounts for approximately 25% of primary energy demand with roughly half of primary home heating fuelled by oil and 11% by solid fuels. Displacing oil and solid fuel usage with air source heat pump (ASHP) technology could offer household cost savings, reductions in emissions, and reduced health impacts. An economic analysis estimates that 60% of homes using oil, have the potential to deliver savings in the region of €600 per annum when considering both running and annualised capital costs. Scenario analysis estimates that a grant of €2400 could increase the potential market uptake of oil users by up to 17% points, whilst a higher oil price, similar to 2013, could further increase uptake from heating oil users by 24% points. Under a combined oil-price and grant scenario, CO_2 emissions reduce by over 4 million tonnes per annum and residential PM_2_._5 and NO_X emissions from oil and peat reduce close to zero. Corresponding health and environmental benefits are estimated in the region of €100m per annum. Sensitivity analyses are presented assessing the impact of alternate discount rates and technology performance. This research confirms the potential for ASHP technology and identifies and informs policy design considerations with regard to oil price trends, access to capital, targeting of grants, and addressing transactions costs. - Highlights: • Air Source Heat Pumps can offer substantial savings over oil fired central heating. • Significant residential air and climate emission reductions are possible. • Associated health and environmental benefits are estimated up to €100m per annum. • Results can inform policy interventions in the residential market to support change.

  14. The effect of economic factors and energy efficiency programs on residential electricity consumption

    Science.gov (United States)

    Sakai, Mihoko

    Many countries have implemented policies to correct market and behavioral failures that lead to inefficient energy use. It is important to know what factors and policies can effectively overcome such failures and improve energy efficiency; however, a comprehensive analysis has been difficult because of data limitations. Using state scores compiled by American organizations recently, and adopting fixed-effects regression models, I analyze the joint impacts of relevant factors and policy programs on residential electricity consumption in each U.S. state. The empirical results reveal that increases in electricity price have small and negative effects, and increases in personal income have positive effects on residential electricity sales per capita (a measure of energy efficiency). The results suggest that it may take time for economic factors to affect electricity sales. The effects of personal income suggest the difficulty of controlling residential electricity consumption; however, they also imply that there is some room in households to reduce electricity use. The study also finds that programs and budgets of several policies seem to be associated with electricity sales. The estimates from a model including interaction terms suggest the importance of including multiple policies when analyzing and designing policies to address electricity efficiency. The results also imply the possibility of rebound effects of some policies, whereby improvements in energy efficiency lead to increases in energy consumption due to the associated lower per unit cost. Future studies should analyze both short-term and long-term effects of economic factors and policies, based on improved and accumulated time series and panel data, in order to design more effective policies for improving residential electricity efficiency.

  15. Analysing socioeconomic diversity and scaling effects on residential electricity load profiles in the context of low carbon technology uptake

    International Nuclear Information System (INIS)

    McKenna, R.; Hofmann, L.; Merkel, E.; Fichtner, W.; Strachan, N.

    2016-01-01

    Adequately accounting for interactions between Low Carbon Technologies (LCTs) at the building level and the overarching energy system means capturing the granularity associated with decentralised heat and power supply in residential buildings. The approach presented here adds novelty in terms of a realistic socioeconomic differentiation by employing dwelling/household archetypes (DHAs) and neighbourhood clusters at the Output Area (OA) level. These archetypes are combined with a mixed integer linear program (MILP) to generate optimum (minimum cost) technology configurations and operation schedules. Even in the baseline case, without any LCT penetration, a substantial deviation from the standard load profile (SLP) is encountered, suggesting that for some neighbourhoods this profile is not appropriate. With the application of LCTs, including heat pumps, micro-CHP and photovoltaic (PV), this effect is much stronger, including more negative residual load, more variability, and higher ramps with increased LCT penetration, and crucially different between neighbourhood clusters. The main policy implication of the study is the importance of understanding electrical load profiles at the neighbourhood level, because of the consequences they have for investment in the overarching energy system, including transmission and distribution infrastructure, and centralised generation plant. Further work should focus on attaining a superior socioeconomic differentiation between households. - Highlights: • Low carbon technologies (LCTs) for heat/electricity in residential buildings. • Socioeconomic effects and interactions with overarching energy system. • Building thermal/electrical model combined with optimisation. • Significant differences between neighbourhood load profiles. • Policy implications: support for LCTs and investment in infrastructure.

  16. Short- and long-run time-of-use price elasticities in Swiss residential electricity demand

    International Nuclear Information System (INIS)

    Filippini, Massimo

    2011-01-01

    This paper presents an empirical analysis on the residential demand for electricity by time-of-day. This analysis has been performed using aggregate data at the city level for 22 Swiss cities for the period 2000-2006. For this purpose, we estimated two log-log demand equations for peak and off-peak electricity consumption using static and dynamic partial adjustment approaches. These demand functions were estimated using several econometric approaches for panel data, for example LSDV and RE for static models, and LSDV and corrected LSDV estimators for dynamic models. The attempt of this empirical analysis has been to highlight some of the characteristics of the Swiss residential electricity demand. The estimated short-run own price elasticities are lower than 1, whereas in the long-run these values are higher than 1. The estimated short-run and long-run cross-price elasticities are positive. This result shows that peak and off-peak electricity are substitutes. In this context, time differentiated prices should provide an economic incentive to customers so that they can modify consumption patterns by reducing peak demand and shifting electricity consumption from peak to off-peak periods. - Highlights: → Empirical analysis on the residential demand for electricity by time-of-day. → Estimators for dynamic panel data. → Peak and off-peak residential electricity are substitutes.

  17. Planning for a Low Carbon Future? Comparing Heat Pumps and Cogeneration as the Energy System Options for a New Residential Area

    Directory of Open Access Journals (Sweden)

    Jukka Heinonen

    2015-08-01

    Full Text Available The purpose of this paper is to compare, from an urban planning perspective, the choice between combined heat and power (CHP and a ground-source heat pump (HP as the energy systems of a new residential area in the light of the uncertainty related to the assessments. There has been a strong push globally for CHP due to its climate mitigation potential compared to separate production, and consequently it is often prioritized in planning without questioning. However, the uncertainties in assessing the emissions from CHP and alternative options in a certain planning situation make it very difficult to give robust decision guidelines. In addition, even the order of magnitude of the climate impact of a certain plan is actually difficult to assess robustly. With a case study of the new residential development of Härmälänranta in Tampere, Finland, we show how strongly the uncertainties related to (1 utilizing average or marginal electricity as the reference; (2 assigning emissions intensities for the production; and (3 allocating the emissions from CHP to heat and electricity affect the results and lead to varying decision guidelines. We also depict how a rather rarely utilized method in assigning the emissions from CHP is the most robust for planning support.

  18. Decomposing final energy use for heating in the residential sector in Austria

    International Nuclear Information System (INIS)

    Holzmann, Angela; Adensam, Heidelinde; Kratena, Kurt; Schmid, Erwin

    2013-01-01

    In Austria a considerable number of measures have been implemented to reduce final energy use for residential heating since the 1990s. The aim of this analysis is to investigate, why – despite these implemented measures – final energy use for heating has not decreased in the expected way. The impact of eight factors on final energy use for heating is quantified by applying the Logarithmic Mean Divisia Index (LMDI I) method. The dataset covers the sector of private households in Austria for the period from 1993 to 2009. The main findings of the analysis are: (1) while technical improvements reduce final energy use for heating significantly, rising comfort needs nearly outweigh these savings. (2) Consumer behaviour reduces calculated final energy use considerably. (3) The extent of this reduction is declining significantly in the period observed. (4) The growing share of single-family houses has increased energy demand for heating in the observed period, though a reversal of this trend is detected from 2007 onwards. (5) The impact of growing floor space per person is the major effect revealed by the analysis. (6) Weather conditions have a major impact on annual fluctuations of energy consumption. -- Highlights: •We did an Index decomposition analysis of the Austrian residential heating demand. •Eight impact factors on heating demand have been identified. •Rising comfort needs outweigh savings caused by technical improvements. •Consumer behaviour has a major impact on residential final energy use for heating. •Weather changes play a major role when analysing annual changes in energy use

  19. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  20. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low-temperature h....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  1. Residential building envelope heat gain and cooling energy requirements

    International Nuclear Information System (INIS)

    Lam, Joseph C.; Tsang, C.L.; Li, Danny H.W.; Cheung, S.O.

    2005-01-01

    We present the energy use situation in Hong Kong from 1979 to 2001. The primary energy requirement (PER) nearly tripled during the 23-year period, rising from 195,405 TJ to 572,684 TJ. Most of the PER was used for electricity generation, and the electricity use in residential buildings rose from 7556 TJ (2099 GWh) to 32,799 TJ (9111 GWh), an increase of 334%. Air-conditioning accounted for about 40% of the total residential sector electricity consumption. A total of 144 buildings completed in the month of June during 1992-2001 were surveyed. Energy performance of the building envelopes was investigated in terms of the overall thermal transfer value (OTTV). To develop the appropriated parameters used in OTTV calculation, long-term measured weather data such as ambient temperature (1960-2001), horizontal global solar radiation (1992-2001) and global solar radiation on vertical surfaces (1996-2001) were examined. The OTTV found varied from 27 to 44 W/m 2 with a mean value of 37.7 W/m 2 . Building energy simulation technique using DOE-2.1E was employed to determine the cooling requirements and hence electricity use for building envelope designs with different OTTVs. It was found that cooling loads and electricity use could be expressed in terms of a simple two-parameter linear regression equation involving OTTV

  2. Residential fuelwood assessment, state of Minnesota, 2007-2008 heating season

    Science.gov (United States)

    Mimi Barzen; Ronald Piva; Chun Yi Wy; Rich. Dahlman

    2009-01-01

    During the spring and summer of 2008, the cooperating partners conducted a survey to determine the volume of residential fuelwood burned during the 2007-2008 heating season. Similar surveys were conducted for the 1960, 1969-1970, 1979-1980, 1984-1985, 1988-1989, 1995-1996, and 2002-2003 heating seasons. These surveys are part of a long-term effort to monitor trends in...

  3. Optimal scheduling for electric heat booster under day-ahead electricity and heat pricing

    DEFF Research Database (Denmark)

    Cai, Hanmin; You, Shi; Bindner, Henrik W.

    2017-01-01

    Multi-energy system (MES) operation calls for active management of flexible resources across energy sectors to improve efficiency and meet challenging environmental targets. Electric heat booster, a solution for Domestic Hot Water (DHW) preparation under Low-Temperature-District-Heating (LTDH......) context, is identified as one of aforementioned flexible resources for electricity and heat sectors. This paper extends the concept of optimal load scheduling under day-ahead pricing from electricity sector only to both electricity and heat sectors. A case study constructing day-ahead energy prices...

  4. Reforming residential electricity tariff in China: Block tariffs pricing approach

    International Nuclear Information System (INIS)

    Sun, Chuanwang; Lin, Boqiang

    2013-01-01

    The Chinese households that make up approximately a quarter of world households are facing a residential power tariff reform in which a rising block tariff structure will be implemented, and this tariff mechanism is widely used around the world. The basic principle of the structure is to assign a higher price for higher income consumers with low price elasticity of power demand. To capture the non-linear effects of price and income on elasticities, we set up a translog demand model. The empirical findings indicate that the higher income consumers are less sensitive than those with lower income to price changes. We further put forward three proposals of Chinese residential electricity tariffs. Compared to a flat tariff, the reasonable block tariff structure generates more efficient allocation of cross-subsidies, better incentives for raising the efficiency of electricity usage and reducing emissions from power generation, which also supports the living standards of low income households. - Highlights: • We design a rising block tariff structure of residential electricity in China. • We set up a translog demand model to find the non-linear effects on elasticities. • The higher income groups are less sensitive to price changes. • Block tariff structure generates more efficient allocation of cross-subsidies. • Block tariff structure supports the living standards of low income households

  5. Restructuring and the retail residential market for power in Pennsylvania

    International Nuclear Information System (INIS)

    Kleit, Andrew N.; Shcherbakova, Anastasia V.; Chen Xu

    2012-01-01

    In January 2010 electricity retail residential rate caps expired in a large part of Pennsylvania, allowing consumers to shop for electricity in the retail market. In this paper we employ customer-level data from the relevant territory to analyze what residential customer and community characteristics impacted the decision of whether or not to switch to an alternative electricity provider, and when to make the switch. Results show that customers with higher usage levels (especially around the time of the program's introduction), electric heating, and those living in more urban and more educated communities with lower unemployment rates and higher median household incomes were both more likely to switch, and more likely to do so faster. Lower switching rates and a slower switching response was observed from customers with more variable month to month usage (perhaps this made them unsure of future benefits from switching), those on alternative residential electricity rates (time-of-day and thermal storage programs), and those new to the relevant area (perhaps due to lack of information about the residential choice program). Critics of retail electricity competition have suggested that it disadvantages poor and elderly ratepayers. Our results do not support this contention. Customers living in communities with higher poverty rates were actually more likely to switch (and do so faster) than middle-income consumers. Communities with higher shares of senior population were not found to have lower switching rates from younger communities. - Highlights: ► We analyze introduction of retail competition in Pennsylvania's electricity sector. ► We evaluate what characteristics influence consumers to switch electric providers. ► Higher usage and electric heat influence customers to switch and to do so faster. ► More variable usage and being new to service area deter switching. ► High poverty rates induce switching; older communities no less likely to switch.

  6. Competitive solar heating systems for residential buildings

    DEFF Research Database (Denmark)

    Furbo, Simon; Thür, Alexander; Fiedler, Frank

    2005-01-01

    The paper describes the ongoing research project “Competitive solar heating systems for residential buildings”. The aim of the project is to develop competitive solar combisystems which are attractive to buyers. The solar combisystems must be attractive compared to traditional energy systems, both....... In Denmark and Norway the focus is on solar heating/natural gas systems, and in Sweden and Latvia the focus is on solar heating/pellet systems. Additionally, Lund Institute of Technology and University of Oslo are studying solar collectors of various types being integrated into the roof and facade......, are the universities: Technical University of Denmark, Dalarna University, University of Oslo, Riga Technical University and Lund Institute of Technology, as well as the companies: Metro Therm A/S (Denmark), Velux A/S (Denmark), Solentek AB (Sweden) and SolarNor (Norway). The project consists of a number of Ph...

  7. An optimization methodology for the design of renewable energy systems for residential net zero energy buildings with on-site heat production

    DEFF Research Database (Denmark)

    Milan, Christian; Bojesen, Carsten; Nielsen, Mads Pagh

    2011-01-01

    The concept of net zero energy buildings (NZEB) has received increased attention throughout the last years. A well adapted and optimized design of the energy supply system is crucial for the performance of such buildings. This paper aims at developing a method for the optimal sizing of renewable...... energy supply systems for residential NZEB involving on-site production of heat and electricity in combination with electricity exchanged with the public grid. The model is based on linear programming and determines the optimal capacities for each relevant supply technology in terms of the overall system...

  8. Price and income elasticities of residential energy demand in Germany

    International Nuclear Information System (INIS)

    Schulte, Isabella; Heindl, Peter

    2017-01-01

    We apply a quadratic expenditure system to estimate price and expenditure elasticities of residential energy demand (electricity and heating) in Germany. Using official expenditure data from 1993 to 2008, we estimate an expenditure elasticity for electricity of 0.3988 and of 0.4055 for space heating. The own price elasticity for electricity is −0.4310 and −0.5008 in the case of space heating. Disaggregation of households by expenditure and socio-economic composition reveals that the behavioural response to energy price changes is weaker (stronger) for low-income (top-income) households. There are considerable economies of scale in residential energy use but scale effects are not well approximated by the new OECD equivalence scale. Real increases in energy prices show a regressive pattern of incidence, implying that the welfare consequences of direct energy taxation are larger for low income households. The application of zero-elasticities in assessments of welfare consequences of energy taxation strongly underestimates potential welfare effects. The increase in inequality is 22% smaller when compared to the application of disaggregated price and income elasticities as estimated in this paper. - Highlights: • We estimate price, income, and expenditure elasticities for residential energy demand in Germany. • We differentiate elasticities by income groups and household type. • Electricity and space heating are necessary goods since the expenditure elasticities are smaller than unity. • Low-income households show a weaker reaction to changing prices when compared to high-income households. • Direct energy taxation has regressive effects, meaning that larger burdens fall upon low-income households.

  9. Potential market-size for renewables in the residential sector of Pakistan

    International Nuclear Information System (INIS)

    Athar, G.R; Imtiaz, M.

    2005-01-01

    Renewable energy-sources can be used for meeting the energy-demand of various endues, like water-pumping for irrigation, process-heat for industries and desalination for potable water-supplies. However, the residential sector has the largest potential for renewable energy usage among all sectors of the economy. At present, the residential sector of Pakistan consumes some 26 million Tone of Oil Equivalent (MTOE) energy: with more than 6 MTOE in the form of commercial energy (electricity, natural gas, kerosene, LPG and coal) and about 20 MTOE in the form of non-commercial energy (wood, dung and crop-residues). Applied Systems Analysis Group (ASAG) has carried out a study to project the energy demand of Pakistan up to the year 2024-25, using an energy-demand model MAED. This model uses simulation technique to evaluate the energy-demand implications of a scenario, describing the assumed evolution of demographic parameters, economic activities, lifestyle of the population and technological improvements. The demographic targets of the Population-Policy of Pakistan and economic targets of Government of Pakistan have been adopted as the basis of our reference scenario. The study shows that the energy-demand of the residential sector will increase by a factor of 1.7, compared to the base-year 2001-2002. The residential sector will need 41. 9 MTOE energy, of which: (I) 5.9 MTOE (72.5 TWh) in the form of electricity to fulfill the energy-needs for lighting, cooling and other electric appliances, (II) 24.4 MTOE for cooking, (III) 5.7 MTOE for water heating, and (IV) 5.8 MTOE for space heating. In all these end-uses, renewable energy can make a contribution depending on the cost of energy, convenience of use and reliability of supply. Although, the government is vigorously pursuing a rural electrification program, a portion of residential sector, particularly in remote areas, will not be electrified even by 2024-25. The non-electrified houses will require 3 to 5 TWh of

  10. The Boom of Electricity Demand in the Residential Sector in the Developing World and the Potential for Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie; McNeil, Michael A.

    2008-05-13

    With the emergence of China as the world's largest energy consumer, the awareness of developing country energy consumption has risen. According to common economic scenarios, the rest of the developing world will probably see an economic expansion as well. With this growth will surely come continued rapid growth in energy demand. This paper explores the dynamics of that demand growth for electricity in the residential sector and the realistic potential for coping with it through efficiency. In 2000, only 66% of developing world households had access to electricity. Appliance ownership rates remain low, but with better access to electricity and a higher income one can expect that households will see their electricity consumption rise significantly. This paper forecasts developing country appliance growth using econometric modeling. Products considered explicitly - refrigerators, air conditioners, lighting, washing machines, fans, televisions, stand-by power, water heating and space heating - represent the bulk of household electricity consumption in developing countries. The resulting diffusion model determines the trend and dynamics of demand growth at a level of detail not accessible by models of a more aggregate nature. In addition, the paper presents scenarios for reducing residential consumption through cost-effective and/or best practice efficiency measures defined at the product level. The research takes advantage of an analytical framework developed by LBNL (BUENAS) which integrates end use technology parameters into demand forecasting and stock accounting to produce detailed efficiency scenarios, which allows for a realistic assessment of efficiency opportunities at the national or regional level. The past decades have seen some of the developing world moving towards a standard of living previously reserved for industrialized countries. Rapid economic development, combined with large populations has led to first China and now India to emerging as &apos

  11. Simulation of hybrid ground-coupled heat pump with domestic hot water heating systems using HVACSIM+

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Ping; Yang, Hongxing [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China); Spitler, Jeffrey D. [School of Mechanical Engineering, Oklahoma State University (United States); Fang, Zhaohong [Ground Source Heat Pump Research Center, Shandong University of Architecture and Engineering, Jinan (China)

    2008-07-01

    A hybrid ground-coupled heat pump (HGCHP) with domestic hot water (DHW) supply system has been proposed in this paper for space cooling/heating and DHW supply for residential buildings in hot-climate areas. A simulation model for this hybrid system is established within the HVACSIM+ environment. A sample system, applied for a small residential apartment located in Hong Kong, is hourly simulated in a typical meteorological year. The conventional GCHP system and an electric heater for DHW supply are also modeled and simulated on an hourly basis within the HVACSIM+ for comparison purpose. The results obtained from this case study show that the HGCHP system can effectively alleviate the imbalanced loads of the ground heat exchanger (GHE) and can offer almost 95% DHW demand. The energy saving for DHW heating is about 70% compared with an electric heater. This proposed scheme, i.e. the HGCHP with DHW supply, is suitable to residential buildings in hot-climate areas, such as in Hong Kong. (author)

  12. Characteristics of residential energy consumption in China: Findings from a household survey

    International Nuclear Information System (INIS)

    Zheng, Xinye; Wei, Chu; Qin, Ping; Guo, Jin; Yu, Yihua; Song, Feng; Chen, Zhanming

    2014-01-01

    A comprehensive survey of 1450 households in 26 Chinese provinces was undertaken in 2012 to identify the characteristics and potential driving forces of residential energy consumption in China. The survey covers six areas: household characteristics, dwelling characteristics, kitchen and home appliances, space heating and cooling, residential transportation, and electricity billing, metering, and pricing options. The results show that a typical Chinese household in 2012 consumed 1426 kilograms standard coal equivalent, which is approximately 44 percent of the 2009 level in the United States and 38 percent of the 2008 level in the EU-27. District heating, natural gas, and electricity are three major residential energy sources, while space heating, cooking, and water heating are three major end-use activities. Moreover, the results suggest a large urban–rural gap in terms of energy sources and purpose of usage. Commercial energy is used mainly for space heating in urban areas, while biomass dominates mainly for cooking purpose in rural areas. The survey results can help decision makers and scholars identify energy conservation opportunities, and evaluate the effectiveness of energy policies. - Highlights: • We develop the first comprehensive survey of residential energy consumption in China. • A typical Chinese household in 2012 consumed 1426 kilograms coal equivalent. • Space heating accounts for half of energy demand. • A large rural–urban gap exists in terms of energy sources and end-use activities. • Results reveal challenges and opportunities for China's energy policy

  13. Energy consumption modeling of air source electric heat pump water heaters

    International Nuclear Information System (INIS)

    Bourke, Grant; Bansal, Pradeep

    2010-01-01

    Electric heat pump air source water heaters may provide an opportunity for significant improvements in residential water heater energy efficiency in countries with temperate climates. As the performance of these appliances can vary widely, it is important for consumers to be able to accurately assess product performance in their application to maximise energy savings and ensure uptake of this technology. For a given ambient temperature and humidity, the performance of an air source heat pump water heater is strongly correlated to the water temperature in or surrounding the condenser. It is therefore important that energy consumption models for these products duplicate the real-world water temperatures applied to the heat pump condenser. This paper examines a recently published joint Australian and New Zealand Standard, AS/NZS 4234: 2008; Heated water systems - Calculation of energy consumption. Using this standard a series TRNSYS models were run for several split type air source electric heat pump water heaters. An equivalent set of models was then run utilizing an alternative water use pattern. Unfavorable errors of up to 12% were shown to occur in modeling of heat pump water heater performance using the current standard compared to the alternative regime. The difference in performance of a model using varying water use regimes can be greater than the performance difference between models of product.

  14. Residential CCHP microgrid with load aggregator: Operation mode, pricing strategy, and optimal dispatch

    International Nuclear Information System (INIS)

    Gu, Wei; Lu, Shuai; Wu, Zhi; Zhang, Xuesong; Zhou, Jinhui; Zhao, Bo; Wang, Jun

    2017-01-01

    Highlights: •A bilateral transaction mode for the residential CCHP microgrid is proposed. •An energy pricing strategy for the residential CCHP system is proposed. •A novel integrated demand response for the residential loads is proposed. •Two-stage operation optimization model for the CCHP microgrid is proposed. •Operations of typical days and annual scale of the CCHP microgrid are studied. -- Abstract: As the global energy crisis, environmental pollution, and global warming grow in intensity, increasing attention is being paid to combined cooling, heating, and power (CCHP) systems that realize high-efficiency cascade utilization of energy. This paper proposes a bilateral transaction mechanism between a residential CCHP system and a load aggregator (LA). The variable energy cost of the CCHP system is analyzed, based on which an energy pricing strategy for the CCHP system is proposed. Under this pricing strategy, the electricity price is constant, while the heat/cool price is ladder-shaped and dependent on the relationship between the electrical, heat, and cool loads. For the LA, an integrated demand response program is proposed that combines electricity-load shifting and a flexible heating/cooling supply, in which a thermodynamic model of buildings is used to determine the appropriate range of heating/cooling supply. Subsequently, a two-stage optimal dispatch model is proposed for the energy system that comprises the CCHP system and the LA. Case studies consisting of three scenarios (winter, summer, and excessive seasons) are delivered to demonstrate the effectiveness of the proposed approach, and the performance of the proposed pricing strategy is also evaluated by annual operation simulations.

  15. Norwegian residential electricity demand - a microeconomic assessment of the growth from 1976 to 1993

    International Nuclear Information System (INIS)

    Halvorsen, B.; Larsen, B.M.

    2001-01-01

    The Norwegian residential electricity consumption increased by an average of 3% annually during the period 1976-1993. Political signals indicate that the growth in Norwegian residential energy consumption should be reduced, and that it may be necessary to increase energy taxes. Based on data for the sample of households from the annual consumer expenditure survey, we study factors that are of importance explaining the growth in Norwegian residential electricity demand during this period. Nearly half of the growth is due to an increase in the number of households, while the rest reflects an increase in average consumption per household. The increase in average consumption per household is due to an increasing number of households possessing electric household appliances such as dryers and dishwashers, an increase in real disposable household income and in the floor space of dwellings. (author)

  16. Residential Central Air Conditioning and Heat Pump Installation – Workshop Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Burlington, MA (United States); Young, Jim [Navigant Consulting, Burlington, MA (United States); Bargach, Youssef [Navigant Consulting, Burlington, MA (United States)

    2016-11-01

    DOE's Building Technologies Office works with researchers and industry partners to develop and deploy technologies that can substantially reduce energy consumption in residential and commercial buildings. This report aims to advance BTO’s energy savings, emissions reduction, and other program goals by identifying research and development (R&D), demonstration and deployment, and other non-regulatory initiatives for improving the design and installation of residential central air conditioners (CAC) and central heat pumps (CHP). Improving the adoption of CAC/CHP design and installation best practices has significant potential to reduce equipment costs, improve indoor air quality and comfort, improve system performance, and most importantly, reduce household energy consumption and costs for heating and cooling by addressing a variety of common installation issues.

  17. Residential bioenergy heating: A study of consumer perceptions of improved woodstoves

    International Nuclear Information System (INIS)

    Nyrud, Anders Q.; Roos, Anders; Sande, Jon Bingen

    2008-01-01

    Consumers' choices play a key role for the development of biomass heating in the residential sector. The city of Oslo has granted subsidies to households who change to new, improved low-emission woodstoves. The purpose of this study is to expand the knowledge about users' experiences and attitudes to residential biomass heating. An adapted model of the Theory of Planned Behavior was used to model households' inclination to continue using their woodstoves for heating. More than 800 questionnaires were collected from households that recently had invested in an improved woodstove. The respondents were satisfied with the new woodstoves. The respondents also considered themselves competent to use and maintain the stove and few had problems acquiring fuelwood. Further analyses showed that the intention to continue to use the new woodstove depends on economic benefits, heating performance, perceived time and effort to operate the stove, environmental effects of heating as well as perceived subjective norm. The results imply that when marketing a modern technology for bioenergy heating, both public authorities and producers should consider issues related to the users' perception of subjective norm, such as perceived status of using bioenergy or environmental concerns, when designing campaigns to promote the use of woodstoves

  18. Combined installation of electric and heat supply for climatic conditions of Iraq

    Science.gov (United States)

    Kaisi, Osama Al; Sidenkov, D. V.

    2017-11-01

    Electricity, heating and cooling are the three main components that make up the energy consumption base in residential, commercial and public buildings around the world. Demand for energy and fuel costs are constantly growing. Combined cooling, heating and power generation or trigeneration can be a promising solution to such a problem, providing an efficient, reliable, flexible, competitive and less harmful alternative to existing heat and cold supply systems. In this paper, scheme of the tri-generation plant on non-aqueous working substances is considered as an installation of a locally centralized electro-heat and cold supply of a typical residential house in a hot climate. The scheme of the combined installation of electro-heat (cold) supply consisted of the vapor power plant and heat pump system on low-boiling working substance for local consumers under the climatic conditions of Iraq is presented. The possibility of using different working substances in the thermodynamic cycles of these units, which will provide better efficiency of such tri-generation systems is shown. The calculations of steam turbine cycles and heat pump part on the selected working substances are conducted. It is proposed to use heat exchangers of plate type as the main exchangers in the combined processing. The developed method of thermal-hydraulic calculation of heat exchangers implemented in MathCad, which allows to evaluate the efficiency of plants of this type using the ε - NTU method. For the selected working substances of the steam part the optimal temperature of heat supply to the steam generator is determined. The results of thermodynamic and technical-economic analysis of the application of various working substances in the “organic” Rankine cycle of the steam turbine unit and the heat pump system of the heat and cold supply system are presented.

  19. The energy-related services are the major sales promotion. Customized electricity and district heat supply technology and services for the newly developed residential area Boerkhauser Feld at Solingen-Aufderhoehe; Die Dienstleistung bringt den (Verkaufs-)Erfolg. Strom- und Waermeversorgung fuer Wohngebiet Boerkhauser Feld in Solingen-Aufderhoehe

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-06-01

    The firm COMUNA-metall, Herford, is the contractor and service provider for installation and operation of the electricity and district heat supply systems based on a modular cogeneration plant (CHP system). The residential area will eventually encompass about 450 residential units, all buildings are low-energy houses. The article explains the systems and gives an initial performance report covering 100 existing residential units. (orig./CB) [German] Die Firma COMUNA-metall, Herford, hat als Dienstleister die Erstellung und den Betrieb einer Strom- und Nahwaermeversorgung mit Kraft-Waerme-Kopplung fuer das Wohngebiet uebernommen, das nach Fertigstellung ca. 450 Wohneinheiten in Niedrigenergiebauweise umfassen wird. Der Beitrag schildert die technischen Einrichtungen und eine erste Leistungsbilanz im Bauabschnitt mit 100 Wohneinheiten. (orig./CB)

  20. Accelerating residential PV expansion: supply analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Payne, Adam; Williams, Robert H.; Duke, Richard

    2001-01-01

    Photovoltaic (PV) technology is now sufficiently advanced that market support mechanisms such as net metering plus a renewable portfolio standard (RPS) could induce rapid PV market growth in grid-connected applications. With such support mechanisms, markets would be sufficiently large that manufacturers could profitably build and operate 100 MW p /yr PV module factories, and electricity costs for residential rooftop PV systems would compare favorably with residential electricity prices in certain areas (e.g., California and the greater New York region in the US). This prospect is illustrated by economic and market analyses for one promising technology (amorphous silicon thin-film PV) from the perspectives of both module manufacturers and buyers of new homes with rooftop PV systems. With public policies that reflect the distributed and environmental benefits offered by PV-and that can sustain domestic PV market demand growth at three times the historical growth rate for a period of the order of two decades - PV could provide 3% of total US electricity supply by 2025. (Author)

  1. Response of residential electricity demand to price: The effect of measurement error

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, Anna [Department of Agricultural Economics, University of Maryland (United States); Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Gibson Institute and Institute for a Sustainable World, School of Biological Sciences, Queen' s University Belfast, Northern Ireland (United Kingdom); Filippini, Massimo, E-mail: mfilippini@ethz.ch [Centre for Energy Policy and Economics (CEPE), ETH Zurich (Switzerland); Department of Economics, University of Lugano (Switzerland)

    2011-09-15

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: > Updated information on price elasticities for the US energy policy. > Taking into account measurement error in the price variable increase price elasticity. > Room for discouraging residential electricity consumption using price increases.

  2. Response of residential electricity demand to price: The effect of measurement error

    International Nuclear Information System (INIS)

    Alberini, Anna; Filippini, Massimo

    2011-01-01

    In this paper we present an empirical analysis of the residential demand for electricity using annual aggregate data at the state level for 48 US states from 1995 to 2007. Earlier literature has examined residential energy consumption at the state level using annual or monthly data, focusing on the variation in price elasticities of demand across states or regions, but has failed to recognize or address two major issues. The first is that, when fitting dynamic panel models, the lagged consumption term in the right-hand side of the demand equation is endogenous. This has resulted in potentially inconsistent estimates of the long-run price elasticity of demand. The second is that energy price is likely mismeasured. To address these issues, we estimate a dynamic partial adjustment model using the Kiviet corrected Least Square Dummy Variables (LSDV) (1995) and the Blundell-Bond (1998) estimators. We find that the long-term elasticities produced by the Blundell-Bond system GMM methods are largest, and that from the bias-corrected LSDV are greater than that from the conventional LSDV. From an energy policy point of view, the results obtained using the Blundell-Bond estimator where we instrument for price imply that a carbon tax or other price-based policy may be effective in discouraging residential electricity consumption and hence curbing greenhouse gas emissions in an electricity system mainly based on coal and gas power plants. - Research Highlights: → Updated information on price elasticities for the US energy policy. → Taking into account measurement error in the price variable increase price elasticity. → Room for discouraging residential electricity consumption using price increases.

  3. External heating of electrical cables and auto-ignition investigation.

    Science.gov (United States)

    Courty, L; Garo, J P

    2017-01-05

    Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Warm homes: Drivers of the demand for heating in the residential sector in New Zealand

    International Nuclear Information System (INIS)

    Howden-Chapman, Philippa; Viggers, Helen; Chapman, Ralph; O'Dea, Des; Free, Sarah; O'Sullivan, Kimberley

    2009-01-01

    New Zealand houses are large, often poorly constructed and heated, by OECD standards, and consequently are colder and damper indoors than recommended by the World Health Organisation. This affects both the energy consumption and the health of households. The traditional New Zealand household pattern of only heating one room of the house has been unchanged for decades, although there has been substantial market penetration of unflued gas heaters and more recently heat pumps. This paper describes the residential sector and the results of two community-based trials of housing and heating interventions that have been designed to measure the impact of (1) retrofitting insulation and (2) replacing unflued gas heaters and electric resistance heaters with heat pumps, wood pellet burners and flued gas heaters. The paper describes findings on the rebound effect or 'take-back'-the extent to which households take the gains from insulation and heating improvements as comfort (higher temperatures) rather than energy savings, and compares energy-saving patterns with those suggested by an earlier study. Findings on these aspects of household space heating are discussed in the context of the New Zealand government's policy drive for a more sustainable energy system, and the implications for climate change policy.

  5. Electricity contract choices of Finnish residential customers. A choice based conjoint analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rouvinen, S.; Matero, J. (Univ. of Eastern Finland, Joensuu (Finland), School of Forest Sciences), e-mail: seppo.rouvinen@uef.fi, e-mail: jukka.matero@uef.fi

    2010-07-01

    Our aim is to examine how different environmental attributes of electricity contracts affect the residential customer choices when heterogeneity in customer preferences and motivations is taken into account. The data was acquired by a mail questionnaire to random sample of Finnish people in October-November 2009 with a response rate of 38 %. In addition to conventional questions, like questions on socio-demographic and agreements of energy related statements, the discrete choice experiment (DCE) of electricity contracts was included. The choice sets in the DCE had three electricity contract alternatives with varying levels of predetermined attributes (including unit price, supplier type, frequency of power outages, energy source and CO{sub 2} emissions). In this paper, we present the findings of our DCE design. Modeling respondent choices resulted in implicit prices for various electricity contract attributes that provide guidance for green marketing strategies of electricity suppliers and energy related informational activities of public institutions. We conclude that currently the potential for increasing demand-based environmental competitiveness from the wood electricity differentiation remains limited as we did not find any significant market segment of residential customers with strong preferences for wood over other sources of electricity (including 'mixture'). (orig.)

  6. Selected cost considerations for geothermal district heating in existing single-family residential areas

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin

    1996-06-01

    In the past, district heating (geothermal or conventionally fueled) has not been widely applied to the single-family residential sector. Low-heat load density is the commonly cited reason for this. Although it's true that load density in these areas is much lower than for downtown business districts, other frequently overlooked factors may compensate for load density. In particular, costs for distribution system installation can be substantially lower in some residential areas due to a variety of factors. This reduced development cost may partially compensate for the reduced revenue resulting from low-load density. This report examines cost associated with the overall design of the system (direct or indirect system design), distribution piping installation, and customer branch lines. It concludes with a comparison of the costs for system development and the revenue from an example residential area.

  7. Flexible use of electricity in heat-only district heating plants

    Directory of Open Access Journals (Sweden)

    Erik Trømborg

    2017-01-01

    Full Text Available European energy systems are in a period of significant transition, with the increasing shares of variable renewable energy (VRE and less flexible fossil-based generation units as predominant factors. The supply-side changes are expected to cause large short-term electricity price volatility. More frequent periods of low electricity prices may mean that electric use in flexible heating systems will become more profitable, and such flexible heating systems may, in turn, improve the integration of increasing shares of VRE. The objective of this study is to analyze the likely future of Nordic electricity price levels and variations and how the expected prices might affect the use of electricity and thermal storage in heat-only district heating plants. We apply the North European energy market model Balmorel to provide scenarios for future hourly electricity prices in years with normal, high, and low inflow levels to the hydro power system. The simulation tool energyPRO is subsequently applied to quantify how these electricity price scenarios affect the hourly use of thermal storage and individual boilers in heat-only district heating plants located in Norway. The two studied example plants use wood chips or heat pump as base load representing common technologies for district heating in Norway. The Balmorel results show that annual differences in inflow is still a decisive factor for Norwegian and Nordic electricity prices in year 2030 and that short-term (daily price variability is expected to increase. In the plant-level simulations, we find that tank storage, which is currently installed in only a few district heating plants in Norway, is a profitable flexibility option that will significantly reduce the use of fossil peak load in both biomass and heat-pump-based systems. Installation of an electric boiler in addition to tank storage is profitable in the heat pump system due to the limited capacity of the heat pump. Electricity will hence, to a

  8. Modeling and off-design performance of a 1 kWe HT-PEMFC (high temperature-proton exchange membrane fuel cell)-based residential micro-CHP (combined-heat-and-power) system for Danish single-family households

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2011-01-01

    A novel proposal for the modeling and operation of a micro-CHP (combined-heat-and-power) residential system based on HT-PEMFC (High Temperature-Proton Exchange Membrane Fuel Cell) technology is described and analyzed to investigate its commercialization prospects. An HT-PEMFC operates at elevated...... temperatures, as compared to Nafion-based PEMFCs and therefore can be a significant candidate for cogeneration residential systems. The proposed system can provide electric power, hot water, and space heating for a typical Danish single-family household. A complete fuel processing subsystem, with all necessary...

  9. Evaluation of fuel-switching opportunities in the residential sector

    OpenAIRE

    Almeida, Aníbal T. de; Lopes, Ana; Carvalho, Anabela; Mariano, Jorge; Nunes, Catarina

    2004-01-01

    The aim of this paper is to analyse the impact of different natural gas and electricity end-use technologies in the residential sector, which compete among themselves in terms of energy consumption and carbon emissions. The analysis of 17 different technology options, which were chosen in order to match the consumption behaviour of a typical Portuguese family, has shown that the use of electric heat pumps, both for space and water-heating, combined with the use of a natural gas cooker, leads ...

  10. State energy price projections for the residential sector, 1992--1993

    International Nuclear Information System (INIS)

    1992-01-01

    The purpose of this report, State Energy Price Projections for the Residential Sector, 1992--1993, is to provide projections of State-level residential prices for 1992 and 1993 for the following fuels: electricity, natural gas, heating oil, liquefied petroleum gas (LPG), kerosene, and coal. Prices for 1991 are also included for comparison purposes. This report also explains the methodology used to produce these estimates and the limitations

  11. External heating of electrical cables and auto-ignition investigation

    Energy Technology Data Exchange (ETDEWEB)

    Courty, L., E-mail: leo.courty@univ-orleans.fr [Univ. Orleans, PRISME EA 4229, 63 Avenue de Lattre de Tassigny, 18020 Bourges (France); Garo, J.P. [Institut P’, UPR 3346 CNRS, ENSMA, Univ. Poitiers, 1 Av. Clément Ader, Téléport 2, BP 40109, 86961 Futuroscope Chasseneuil (France)

    2017-01-05

    Highlights: • Electrical cables pyrolysis and flammability have been studied. • Two different experimental setups were used to study cables mass loss and flammability. • A 1-D thermal model for cables mass loss and temperature is proposed. • Spontaneous and piloted ignitions have been investigated. - Abstract: Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables.

  12. External heating of electrical cables and auto-ignition investigation

    International Nuclear Information System (INIS)

    Courty, L.; Garo, J.P.

    2017-01-01

    Highlights: • Electrical cables pyrolysis and flammability have been studied. • Two different experimental setups were used to study cables mass loss and flammability. • A 1-D thermal model for cables mass loss and temperature is proposed. • Spontaneous and piloted ignitions have been investigated. - Abstract: Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables.

  13. Challenge: Getting Residential Users to Shift Their Electricity Usage Patterns

    DEFF Research Database (Denmark)

    Brewer, Robert S.; Verdezoto, Nervo; Rasmussen, Mia Kruse

    2015-01-01

    electricity use from the less desirable times to more desirable times, including: feedback technology, pricing incentives, smart appliances, and energy storage. Based on our experience in this area, we present three challenges for residential shifting: getting users to understand the concept of shifting...

  14. Wind power integration with heat pumps, heat storages, and electric vehicles - Energy systems analysis and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Hedegaard, K.

    2013-09-15

    This PhD investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing research, the main focus is put on individual heat pumps in the residential sector (one-family houses) and the possibilities for flexible operation, using the heat storage options available. Several energy systems analyses are performed using the energy system models, Balmorel, developed at the former TSO, ElkraftSystem, and, EnergyPLAN, developed at Aalborg University. The Danish energy system towards 2030, with wind power penetrations of up to 60 %, is used as a case study in most of the analyses. Both models have been developed further, resulting in an improved representation of individual heat pumps and heat storages. An extensive model add-on for Balmorel renders it possible to optimise investment and operation of individual heat pumps and different types of heat storages, in integration with the energy system. Total costs of the energy system are minimised in the optimisation. The add-on incorporates thermal building dynamics and covers various different heat storage options: intelligent heat storage in the building structure for houses with radiator heating and floor heating, respectively, heat accumulation tanks on the space heating circuit, as well as hot water tanks. In EnergyPLAN, some of the heat storage options have been modelled in a technical optimisation that minimises fuel consumption of the energy system and utilises as much wind power as possible. The energy systems analyses reveal that in terms of supporting wind power integration, the installation of individual heat pumps is an important step, while adding heat storages to the heat pumps is less influential. When equipping the heat pumps with heat storages, only moderate system benefits can be gained. Hereof, the main system benefit is that the need for peak/reserve capacity investments can be reduced through peak load shaving; in

  15. Game-Theoretic Energy Management for Residential Users with Dischargeable Plug-in Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available The plug-in electric vehicle (PEV has attracted more and more attention because of the energy crisis and environmental pollution, which is also the main shiftable load of the residential users’ demand side management (DSM system in the future smart grid (SG. In this paper, we employ game theory to provide an autonomous energy management system among residential users considering selling energy back to the utility company by discharging the PEV’s battery. By assuming all users are equipped with smart meters to execute automatic energy consumption scheduling (ECS and the energy company can adopt adequate pricing tariffs relating to time and level of energy usage, we formulate an energy management game, where the players are the residential users and the strategies are their daily schedules of household appliance use. We will show that the Nash equilibrium of the formulated energy management game can guarantee the global optimization in terms of minimizing the energy costs, where the depreciation cost of PEV’s battery because of discharging and selling energy back is also considered. Simulation results verify that the proposed game-theoretic approach can reduce the total energy cost and individual daily electricity payment. Moreover, since plug-in electric bicycles (PEBs are currently widely used in China, simulation results of residential users owing household appliances and bidirectional energy trading of PEBs are also provided and discussed.

  16. Electric vehicle - near or far

    Energy Technology Data Exchange (ETDEWEB)

    Laiho, Y.

    1997-11-01

    Traffic is rapidly becoming the number one environmental problem, especially in metropolitan areas. Electric vehicles have many important advantages to offer. Air quality would be improved, since electric vehicles do not pollute the environment. The improvement obtained might be equated with that resulting from the introduction of district heat for the heating of residential buildings. Electric vehicles also present considerable potential for energy conservation

  17. Wood energy for residential heating in Alaska: current conditions, attitudes, and expected use

    Science.gov (United States)

    David L. Nicholls; Allen M. Brackley; Valerie. Barber

    2010-01-01

    This study considered three aspects of residential wood energy use in Alaska: current conditions and fuel consumption, knowledge and attitudes, and future use and conditions. We found that heating oil was the primary fuel for home heating in southeast and interior Alaska, whereas natural gas was used most often in south-central Alaska (Anchorage). Firewood heating...

  18. Hybrid renewable energy system application for electricity and heat supply of a residential building

    Directory of Open Access Journals (Sweden)

    Nakomčić-Smaragdakis Branka B.

    2016-01-01

    Full Text Available Renewable and distributed energy systems could provide a solution to the burning issue of reliable and clean supply of energy, having in mind current state and future predictions for population growth and fossil fuel scarcity. Hybrid renewable energy systems are novelty in Serbia and warrant further detailed research. The aim of this paper is to analyze the application of renewable energy sources(RES for electricity and heat supply of a typical household in Serbia, as well as the cost-effectiveness of the proposed system. The influence of feed-in tariff change on the value of the investment is analyzed. Small, grid-connected hybrid system (for energy supply of a standard household, consisting of geothermal heat pump for heating/cooling, solar photovoltaic panels and small wind turbine for power supply is analyzed as a case study. System analysis was conducted with the help of RETScreen software. Results of techno-economics analysis have shown that investing in geothermal heat pump and photovoltaic panels is cost-effective, while that is not the case with small wind turbine.

  19. Monitored performance of residential geothermal heat pumps in central Texas and Southern Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, W.N.

    1997-11-01

    This report summarizes measured performance of residential geothermal heat pumps (GHP`s) that were installed in family housing units at Ft. Hood, Texas and at Selfridge Air National Guard base in Michigan. These units were built as part of a joint Department of Defense/Department of Energy program to evaluate the energy savings potential of GHP`s installed at military facilities. At the Ft. Hood site, the GHP performance was compared to conventional forced air electric air conditioning and natural gas heating. At Selfridge, the homes under test were originally equipped with electric baseboard heat and no air conditioning. Installation of the GHP systems at both sites was straightforward but more problems and costs were incurred at Selfridge because of the need to install ductwork in the homes. The GHP`s at both sites produced impressive energy savings. These savings approached 40% for most of the homes tested. The low cost of energy on these bases relative to the incremental cost of the GHP conversions precludes rapid payback of the GHP`s from energy savings alone. Estimates based on simple payback (no inflation and no interest on capital) indicated payback times from 15 to 20 years at both sites. These payback times may be reduced by considering the additional savings possible due to reduced maintenance costs. Results are summarized in terms of 15 minute, hourly, monthly, and annual performance parameters. The results indicate that all the systems were working properly but several design shortcomings were identified. Recommendations are made for improvements in future installations at both sites.

  20. Electricity and heat supply of a settlement at different standards of energy efficiency; Strom- und Waermeversorgung einer Siedlung bei unterschiedlichen Energieeffizienz-Standards

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, Jens; Tschetschorke, Katja

    2013-07-15

    The underlying study analyses the ecologic impact and the economic efficiency of several conventional and innovative heat supply systems to provide a quarter heat for space and water heating and electricity for residential and commercial application and for street lighting. Retrofits of buildings change the ratio of demands for electricity and heat. The demand for heat decreases more than the demand for electricity, and the share of distribution losses in heat grids rises. The question is if it is still economically efficient to build or extend local and long-distance district heating networks. Demands for final and primary energy, greenhouse gas emissions and costs (for operation, energy consumption and investments) of the different systems are compared and rated both in charts and tables. A sensitivity analysis includes increasing energy purchasing costs and assesses the possible economic efficiency of the supply systems in future. Another sensitivity analysis estimates how the climate impact of the supply systems for heat and electricity changes if electricity generation becomes less harmful for climate. Additionally, costs for environmental damage - so-called external costs - are internalised in the analysis of economic efficiency. In an overall rating ecologic and economically efficient systems are recommended.

  1. Integrated evaluation of radiative heating systems for residential buildings

    International Nuclear Information System (INIS)

    Anastaselos, Dimitrios; Theodoridou, Ifigeneia; Papadopoulos, Agis M.; Hegger, Manfred

    2011-01-01

    Based on the need to reduce CO 2 emissions and minimize energy dependency, the EU Member States have set ambitious energy policies goals and have developed respective, specific regulations, in order to improve the energy performance of the building sector. Thus, specific measures regarding the buildings' envelope, the use of efficient HVAC technologies and the integration of renewable energy systems are being constantly studied and promoted. The effective combination of these three main aspects will consequently result in maximum energy efficiency. Germany has played a key role in this development, with intensive work focusing in the improvement of the energy behaviour of the residential building stock. In this paper, the use of radiative heating systems placing special emphasis on infrared is being studied as part of the energy renovation of residential buildings from the 1970's. This is done by applying an integrated assessment model to evaluate specific interventions regarding the improvement of the energy behaviour of the buildings' envelope and the use of radiative heating systems, based on a thorough Life Cycle Analysis according to criteria of energy, economic and environmental performance, as well as thermal comfort. -- Highlights: → Assessment of energy, economic and environmental performance of heating systems. → Life Cycle Analysis in combination with the quality of thermal comfort. → Effectiveness of interventions in already partially insulated buildings.

  2. The potential demand for bioenergy in residential heating applications (bio-heat) in the UK based on a market segment analysis

    International Nuclear Information System (INIS)

    Jablonski, S.; Pantaleo, A.; Bauen, A.; Pearson, P.; Panoutsou, C.; Slade, R.

    2008-01-01

    How large is the potential demand for bio-heat in the UK? Whilst most research has focused on the supply of biomass for energy production, an understanding of the potential demand is crucial to the uptake of heat from bioenergy. We have designed a systematic framework utilising market segmentation techniques to assess the potential demand for biomass heat in the UK. First, the heat market is divided into relevant segments, characterised in terms of their final energy consumption, technological and fuel supply options. Second, the key technical, economic and organisational factors that affect the uptake of bioenergy in each heat segment are identified, classified and then analysed to reveal which could be strong barriers, which could be surmounted easily, and for which bioenergy heat represents an improvement compared to alternatives. The defined framework is applied to the UK residential sector. We identify provisionally the most promising market segments for bioenergy heat, and their current levels of energy demand. We find that, depending on the assumptions, the present potential demand for bio-heat in the UK residential sector ranges between 3% (conservative estimate) and 31% (optimistic estimate) of the total energy consumed in the heat market. (author)

  3. Price freezes, durables and residential electricity demand - Evidence from the Greater Buenos Aires

    Energy Technology Data Exchange (ETDEWEB)

    Casarin, Ariel; Delfino, Maria Eugenia

    2010-09-15

    This paper examines the determinants of residential electricity demand in the Greater Buenos Aires between 1997 and 2006. During the second half of this period, residential tariffs remained nominally fixed, while an income boom boosted up the sales of durables. This study differs from previous works in that it explicitly considers the impact of the stock of air-conditioners on residential demand. The paper reports short- and long-run elasticities and examines the contribution of prices and durables to recent demand growth. Simulations illustrate the impact of prices and durables on future demand.

  4. Prediction of greenhouse gas reduction potential in Japanese residential sector by residential energy end-use model

    International Nuclear Information System (INIS)

    Shimoda, Yoshiyuki; Yamaguchi, Yukio; Okamura, Tomo; Taniguchi, Ayako; Yamaguchi, Yohei

    2010-01-01

    A model is developed that simulates nationwide energy consumption of the residential sector by considering the diversity of household and building types. Since this model can simulate the energy consumption for each household and building category by dynamic energy use based on the schedule of the occupants' activities and a heating and cooling load calculation model, various kinds of energy-saving policies can be evaluated with considerable accuracy. In addition, the average energy efficiency of major electric appliances used in the residential sector and the percentages of housing insulation levels of existing houses is predicted by the 'stock transition model.' In this paper, energy consumption and CO 2 emissions in the Japanese residential sector until 2025 are predicted. For example, as a business - as-usual (BAU) case, CO 2 emissions will be reduced by 7% from the 1990 level. Also evaluated are mitigation measures such as the energy efficiency standard for home electric appliances, thermal insulation code, reduction of standby power, high-efficiency water heaters, energy-efficient behavior of occupants, and dissemination of photovoltaic panels.

  5. Photovoltaic electricity generation: Value for residential and commercial sectors

    Science.gov (United States)

    Bhattacharjee, Ujjwal

    The photovoltaic (PV) industry in the US has seen an upsurge in recent years, and PV holds great promise as a renewable technology with no greenhouse gas emissions with its use. We aim to assess the value of PV based electricity for users in the residential and commercial sectors focusing on the financial impacts it has, which may not be greatly recognized. Specifically, we pursue two goals. First, the emerging 'renewable portfolio standard (RPS)' adopted in several states in the country has been a driving force for large scale PV deployment, but financial incentives offered to PV in different RPS states differ considerably. We use life cycle cost model to estimate the cost of PV based electricity for thirty-two RPS states in the country. Results indicate that the levelized cost of PV electricity is high (40 to 60 Cents/kWh). When the contribution of the financial incentives (along with the cost of energy saved) is taken into account, the cost of PV based electricity is negative in some RPS states such as California, New Jersey, New York, while for most of the RPS states the cost of PV electricity continues to remain high. In addition, the states with negative or low cost of PV electricity have been driving the PV diffusion in the residential sector. Therefore, a need to adjust the financial incentive structure in different RPS states is recommended for homogenous development of the residential PV market in the country. Second, we assess the value of the PV in reducing the highest peak load demand in commercial buildings and hence the high value demand charge. The Time-of-Use (TOU) based electricity tariff is widely used by electric utilities in the commercial sector. Energy and peak load are two important facets of the TOU tariff regime. Tools are well established to estimate the energy contribution from a PV system (installed in a commercial building), but not power output on a short time interval. A joint conditional probability model has been developed that

  6. Moving from Outsider to Insider: Peer Status and Partnerships between Electricity Utilities and Residential Consumers

    Science.gov (United States)

    Morris, Peter; Buys, Laurie; Vine, Desley

    2014-01-01

    An electricity demand reduction project based on comprehensive residential consumer engagement was established within an Australian community in 2008. By 2011, both the peak demand and grid supplied electricity consumption had decreased to below pre-intervention levels. This case study research explored the relationship developed between the utility, community and individual consumer from the residential customer perspective through qualitative research of 22 residential households. It is proposed that an energy utility can be highly successful at peak demand reduction by becoming a community member and a peer to residential consumers and developing the necessary trust, access, influence and partnership required to create the responsive environment to change. A peer-community approach could provide policymakers with a pathway for implementing pro-environmental behaviour for low carbon communities, as well as peak demand reduction, thereby addressing government emission targets while limiting the cost of living increases from infrastructure expenditure. PMID:24979234

  7. Assessing Residential Customer Satisfaction for Large Electric Utilities

    OpenAIRE

    Lea Kosnik; L. Douglas Smith; Satish Nayak; Maureen Karig; Mark Konya; Kristy Lovett; Zhennan Liu; Harrison Luvai

    2015-01-01

    Electric utilities, like other service organizations, rely on customer surveys to assess the quality of their services and customer relations. With responses to an in-depth survey of 2,216 residential customers, complementary data from geo-coded public sources, aggregate assessments of performance by J.D. Power & Associates from their independent surveys, historical records of individual customer usage and bill payments, streams of published media content and records of actual service deliver...

  8. Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.

  9. Numerical analysis of a magnetocaloric heat pump implementation into a residential building

    DEFF Research Database (Denmark)

    Johra, Hicham

    of the magneto-caloric heat pump in a single hydronic loop coupling directly the heat source and the heat sink without additional heat exchangers. Moreover, several parameters can be controlled in order to perform efficient part load power generation. The objective of this work is to understand how to integrate...... a magneto-caloric heat pump into a residential building and establish a control strategy for such device. A numerical model of a single family house with water based under-floor heating and horizontal ground source heat exchanger is created. It is used to demonstrate the feasibility and the advantages...... of the integrated magneto-caloric heat pump system is compared with conventional heat pumps one....

  10. HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

    OpenAIRE

    近藤, 修平; 鉾井, 修一

    2011-01-01

    In order to the evaluate heat loss from hot water supply lines in a residential building, hot water demand in a house in Chiba prefecture was measured and analyzed. The following results were obtained. 1. The heat loss of the hot water supply line was about 132kJ for the shower and 110kJ for the bathtub in winter. Since the temperature difference between the inlet and outlet of the hot water supply line is small, the measured heat loss from the hot water supply line sometimes becomes negative...

  11. Technology line and case analysis of heat metering and energy efficiency retrofit of existing residential buildings in Northern heating areas of China

    International Nuclear Information System (INIS)

    Zhao Jing; Zhu Neng; Wu Yong

    2009-01-01

    The building area in northern heating areas accounting for 70% of the total land area in China is 6,500,000,000 m 2 . The average heating energy consumption in northern China is 100-200% times more than developed countries in the same latitude. This paper introduced firstly the heat metering and energy efficiency retrofit background of existing residential buildings in northern heating areas of China organized by mohurd and MOF, and then put forward the total principle and contents of retrofit. Through analyzing some retrofit cases in Germany, Poland and China, some technological experiences were summarized and finally a technology line suitable for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China which involved retrofit for heat metering and temperature regulation of heating systems, heat balance of heat source and network, and building envelope was described to provide a systematic, scientific, technological guide for the retrofit projects of 0.15 billion m 2 in 'the Eleventh Five-Year Plan' period.

  12. Residential response to voluntary time-of-use electricity rates

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa Baladi, S. [Laurits R. Christensen Associates, Inc. Ames, IA 50011-1070 (United States); Herriges, Joseph A. [Iowa State University, 280D Heady Hall, Department of Economics, Iowa State University, Ames, IA 50011-1070 (United States); Sweeney, Thomas J. [MidAmerican Energy, Des Moines, Iowa (United States)

    1998-09-01

    The response of residential households to voluntary Time-of-Use (TOU) electricity rates is estimated using data from a recent experiment at Midwest Power Systems of Iowa. The study`s design allows us to examine both the participation decision and the customer`s load pattern changes once the TOU rate structure was in effect. Substitution elasticities between on-peak and off-peak electricity usage are estimated and compared to those obtained in earlier mandatory programs, indicating whether program volunteers are more responsive to TOU pricing than the typical household. Attitudinal questionnaires allow us to examine the role of usage perceptions in program participation

  13. Residential implementation of critical-peak pricing of electricity

    International Nuclear Information System (INIS)

    Herter, Karen

    2007-01-01

    This paper investigates how critical-peak pricing (CPP) affects households with different usage and income levels, with the goal of informing policy makers who are considering the implementation of CPP tariffs in the residential sector. Using a subset of data from the California Statewide Pricing Pilot of 2003-04, average load change during summer events, annual percent bill change, and post-experiment satisfaction ratings are calculated across six customer segments, categorized by historical usage and income levels. Findings show that high-use customers respond significantly more in kW reduction than do low-use customers, while low-use customers save significantly more in percentage reduction of annual electricity bills than do high-use customers-results that challenge the strategy of targeting only high-use customers for CPP tariffs. Across income levels, average load and bill changes were statistically indistinguishable, as were satisfaction rates-results that are compatible with a strategy of full-scale implementation of CPP rates in the residential sector. Finally, the high-use customers earning less than $50,000 annually were the most likely of the groups to see bill increases-about 5% saw bill increases of 10% or more-suggesting that any residential CPP implementation might consider targeting this customer group for increased energy efficiency efforts

  14. MICRO-CHP System for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Gerstmann

    2009-01-31

    This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

  15. Charging Schedule for Electric Vehicles in Danish Residential Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2015-01-01

    energy sources like wind in power systems. The EV batteries could be used to charge during periods of excess electricity production from wind power and reduce the charging rate or discharge on deficit of power in the grid, supporting system stability and reliability. By providing such grid services......The prospects of Electric Vehicles (EVs) in providing clean transportation and supporting renewable electricity is widely discussed in sustainable energy forums worldwide. The battery storage of EVs could be used to address the variability and unpredictability of electricity produced from renewable......, the vehicle owner, vehicle fleet operator and other parties involved in the process could economically benefit from the process. This paper investigates an optimal EV charging plan in Danish residential distribution grids in view of supporting high volumes of wind power in electricity grids. The results...

  16. Heat and electricity generating methods

    International Nuclear Information System (INIS)

    Buter, J.

    1977-01-01

    A short synopsis on the actual methods of heating of lodgings and of industrial heat generation is given. Electricity can be generated in steam cycles heated by burning of fossil fuels or by nuclear energy. A valuable contribution to the electricity economy is produced in the hydroelectric power plants. Besides these classical methods, also the different procedures of direct electricity generation are treated: thermoelectric, thermionic, magnetohydrodynamic power sources, solar and fuel cells. (orig.) [de

  17. Thermodynamic analysis of vapor compression heat pump cycle for tap water heating and development of CO_2 heat pump water heater for residential use

    International Nuclear Information System (INIS)

    Saikawa, Michiyuki; Koyama, Shigeru

    2016-01-01

    Highlights: • The ideal vapor compression cycle for tap water heating and its COP were defined. • It was verified theoretically that CO_2 achieves the highest COP for tap water heating. • The prototype of CO_2 heat pump water heater for residential use was developed. • Further COP improvement of CO_2 heat pump water heater was estimated. - Abstract: The ideal vapor compression cycle for tap water heating and its coefficient of performance (COP) have been studied theoretically at first. The ideal cycle is defined as the cycle whose high temperature heat source varies temperature with constant specific heat and other processes are same as the reverse Carnot cycle. The COP upper limit of single stage compression heat pump cycle for tap water heating with various refrigerants such as fluorocarbons and natural refrigerants was calculated. The refrigerant which achieves the highest COP for supplying hot water is CO_2. Next, the prototype of CO_2 heat pump water heater for residential use has been developed. Its outline and experimental results are described. Finally its further possibility of COP improvement has been studied. The COP considered a limit from a technical point of view was estimated about 6.0 at the Japanese shoulder season (spring and autumn) test condition of heating water from 17 °C to 65 °C at 16 °C heat source air temperature (dry bulb)/12 °C (wet bulb).

  18. Modeling and simulation of a residential micro-CHP system based on HT-PEMFC technology

    DEFF Research Database (Denmark)

    Arsalis, Alexandros; Nielsen, Mads Pagh; Kær, Søren Knudsen

    2009-01-01

    Combined-heat-and-power (CHP) technology is a well known and proved method to produce simultaneously power and heat at high efficiencies. This can be further improved by the introduction of a novel micro-CHP residential system based on High Temperature-Proton Exchange Membrane Fuel Cell (HT-PEMFC......). The HT-PEMFC (based on PBI-membrane technology) operates at temperatures near 200oC, and this can be an ideal match for cogeneration residential systems. The proposed system provides electric power, hot water, and space heating for a typical household (1-5 kWe, 5-10 kWth). The micro-CHP system...

  19. Electricity/natural gas competition in Quebec

    International Nuclear Information System (INIS)

    Bernard, J.-T.

    1992-01-01

    The evolution of energy market shares (electricity, natural gas and oil products) in Quebec's residential and commercial sectors in the 1980s shows that energy source relative prices have influenced consumer behavior as expected. A set of comparisons from space and water heating markets in these sectors with regard to prices paid by consumers and costs incurred by society in general is presented. For the residential sector, it is seen that consumers pay only a fraction of the cost for electric space and water heating; the same service could be provided at smaller cost by natural gas. For the commercial sector, the electricity and natural gas tariffs convey the appropriate message with respect to the cost incurred in providing the service. 6 refs., 7 tabs

  20. Improved reliability of residential heat pumps; Foerbaettrad driftsaekerhet hos villavaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Larsson, Kristin; Jensen, Sara; Larsson, Johan; Berg, Johan; Lidbom, Peter; Rolfsman, Lennart

    2012-07-01

    Today, heat pump heating systems are common in Swedish single-family houses. Many owners are pleased with their installation, but statistics show that a certain number of heat pumps break every year, resulting in high costs for both insurance companies and owners. On behalf of Laensfoersaekringars Forskningsfond, SP Energy Technology has studied the cause of the most common failures for residential heat pumps. The objective of the study was to suggest what measures to be taken to reduce the number of failures, i.e. improving the reliability of heat pumps. The methods used were analysis of public failure statistics and sales statistics and interviews with heat pump manufacturers, installers, service representatives and assessors at Laensfoersaekringar. In addition, heat pump manuals have been examined and literature searches for various methods for durability tests have been performed. Based on the outcome from the interviews the most common failures were categorized by if they; 1. Could have been prevented by better operation and maintenance of the heat pump. 2. Caused by a poorly performed installation. 3. Could have been prevented if certain parameters had been measured, recorded and followed up. 4. Are due to poor quality of components or systems. However, the results show that many of the common failures fall into several different categories and therefore, different types of measures must be taken to improve the operational reliability of residential heat pumps. The interviews tell that failures often are caused by poor installation, neglected maintenance and surveillance, and poor quality of standard components or that components are used outside their declared operating range. The quality of the installations could be improved by increasing installers' knowledge about heat pumps and by requiring that an installation protocol shall be filled-in. It is also important that the owner of the heat pump performs the preventive maintenance recommended by the

  1. Improved reliability of residential heat pumps; Foerbaettrad driftsaekerhet hos villavaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Larsson, Kristin; Jensen, Sara; Larsson, Johan; Berg, Johan; Lidbom, Peter; Rolfsman, Lennart

    2012-07-01

    Today, heat pump heating systems are common in Swedish single-family houses. Many owners are pleased with their installation, but statistics show that a certain number of heat pumps break every year, resulting in high costs for both insurance companies and owners. On behalf of Laensfoersaekringars Forskningsfond, SP Energy Technology has studied the cause of the most common failures for residential heat pumps. The objective of the study was to suggest what measures to be taken to reduce the number of failures, i.e. improving the reliability of heat pumps. The methods used were analysis of public failure statistics and sales statistics and interviews with heat pump manufacturers, installers, service representatives and assessors at Laensfoersaekringar. In addition, heat pump manuals have been examined and literature searches for various methods for durability tests have been performed. Based on the outcome from the interviews the most common failures were categorized by if they; 1. Could have been prevented by better operation and maintenance of the heat pump. 2. Caused by a poorly performed installation. 3. Could have been prevented if certain parameters had been measured, recorded and followed up. 4. Are due to poor quality of components or systems. However, the results show that many of the common failures fall into several different categories and therefore, different types of measures must be taken to improve the operational reliability of residential heat pumps. The interviews tell that failures often are caused by poor installation, neglected maintenance and surveillance, and poor quality of standard components or that components are used outside their declared operating range. The quality of the installations could be improved by increasing installers' knowledge about heat pumps and by requiring that an installation protocol shall be filled-in. It is also important that the owner of the heat pump performs the preventive maintenance recommended by the

  2. Integration of Thermoelectric Generators and Wood Stove to Produce Heat, Hot Water, and Electrical Power

    Science.gov (United States)

    Goudarzi, A. M.; Mazandarani, P.; Panahi, R.; Behsaz, H.; Rezania, A.; Rosendahl, L. A.

    2013-07-01

    Traditional fire stoves are characterized by low efficiency. In this experimental study, the combustion chamber of the stove is augmented by two devices. An electric fan can increase the air-to-fuel ratio in order to increase the system's efficiency and decrease air pollution by providing complete combustion of wood. In addition, thermoelectric generators (TEGs) produce power that can be used to satisfy all basic needs. In this study, a water-based cooling system is designed to increase the efficiency of the TEGs and also produce hot water for residential use. Through a range of tests, an average of 7.9 W was achieved by a commercial TEG with substrate area of 56 mm × 56 mm, which can produce 14.7 W output power at the maximum matched load. The total power generated by the stove is 166 W. Also, in this study a reasonable ratio of fuel to time is described for residential use. The presented prototype is designed to fulfill the basic needs of domestic electricity, hot water, and essential heat for warming the room and cooking.

  3. What do customers want from improved residential electricity services? Evidence from a choice experiment

    International Nuclear Information System (INIS)

    Huh, Sung-Yoon; Woo, JongRoul; Lim, Sesil; Lee, Yong-Gil; Kim, Chang Seob

    2015-01-01

    Improvements in customer satisfaction as well as product/service quality represent a common objective of all businesses, and electricity services are no exception. Using choice experiments and a mixed logit model, this study quantitatively analyzes customers' preferences and their marginal willingness to pay for improved residential electricity services. The study provides an ex ante evaluation of customers' acceptance of hypothetical electricity services. According to the results, customers consider the electricity bill and the electricity mix as the two most important attributes when choosing their electricity services. Customers are willing to pay 2.2% more in the average electricity bill (an additional monthly electricity bill of KRW 1,064; USD 0.96) for a significant increase in the share of renewable energy, which is far less than the actual cost of achieving this renewable target. Therefore, it is better to maintain the current electricity mix in principle, and the renewable share should be gradually expanded instead of making a sudden change in the electricity mix. In addition, customers are willing to pay KRW 6,793 (USD 6.15) more to reduce blackouts once in a year and KRW 64/year (USD 0.06/year) to reduce a minute of each blackout. -- Highlights: •Customers' preferences for improved residential electricity services are analyzed. •Empirical setting is a sample of residents in South Korea. •The electricity bills and electricity mix are important to customers. •Increase in electricity bill of different electricity mix is considered

  4. Life cycle primary energy analysis of residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, Leif; Joelsson, Anna [Ecotechnology, Department of Engineering and Sustainable Development, Mid Sweden University, SE-831 25 Oestersund (Sweden)

    2010-02-15

    The space heating demand of residential buildings can be decreased by improved insulation, reduced air leakage and by heat recovery from ventilation air. However, these measures result in an increased use of materials. As the energy for building operation decreases, the relative importance of the energy used in the production phase increases and influences optimization aimed at minimizing the life cycle energy use. The life cycle primary energy use of buildings also depends on the energy supply systems. In this work we analyse primary energy use and CO{sub 2} emission for the production and operation of conventional and low-energy residential buildings. Different types of energy supply systems are included in the analysis. We show that for a conventional and a low-energy building the primary energy use for production can be up to 45% and 60%, respectively, of the total, depending on the energy supply system, and with larger variations for conventional buildings. The primary energy used and the CO{sub 2} emission resulting from production are lower for wood-framed constructions than for concrete-framed constructions. The primary energy use and the CO{sub 2} emission depend strongly on the energy supply, for both conventional and low-energy buildings. For example, a single-family house from the 1970s heated with biomass-based district heating with cogeneration has 70% lower operational primary energy use than if heated with fuel-based electricity. The specific primary energy use with district heating was 40% lower than that of an electrically heated passive row house. (author)

  5. Proton exchange membrane fuel cell for cooperating households: A convenient combined heat and power solution for residential applications

    International Nuclear Information System (INIS)

    Cappa, Francesco; Facci, Andrea Luigi; Ubertini, Stefano

    2015-01-01

    In this paper we compare the technical and economical performances of a high temperature proton exchange membrane fuel cell with those of an internal combustion engine for a 10 kW combined heat and power residential application. In a view of social innovation, this solution will create new partnerships of cooperating families aiming to reduce the energy consumption and costs. The energy system is simulated through a lumped model. We compare, in the Italian context, the total daily operating cost and energy savings of each system with respect to the separate purchase of electricity from the grid and production of the thermal energy through a standard boiler. The analysis is carried out with the energy systems operating with both the standard thermal tracking and an optimized management. The latter is retrieved through an optimization methodology based on the graph theory. We show that the internal combustion engine is much more affected by the choice of the operating strategy with respect to the fuel cell, in terms long term profitability. Then we conduct a net present value analysis with the aim of evidencing the convenience of using a high temperature proton exchange membrane fuel cell for cogeneration in residential applications. - Highlights: • Fuel cells are a feasible and economically convenient solution for residential CHP. • Control strategy is fundamental for the economical performance of a residential CHP. • Flexibility is a major strength of the fuel cell CHP.

  6. 76 FR 18105 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Central Air...

    Science.gov (United States)

    2011-04-01

    ... the lab-added transformer. Id. Under this proposal, the instrument used to measure the electrical... the low-voltage transformer used when testing coil-only residential central air conditioners and heat... the Low-Voltage Transformer Used When Testing Coil- Only Central Air Conditioners and Heat Pumps and...

  7. Lifecycle cost and CO2 emissions of residential heat and electricity prosumers in Finland and the Netherlands

    NARCIS (Netherlands)

    Manrique Delgado, B.; Kotireddy, R.R.; Cao, S.; Hasan, A.; Hoes, P.-J.; Hensen, J.L.M.; Sirén, K.

    2018-01-01

    The complexity of finding solutions to reach energy sustainability in the built environment poses a significant challenge. Therefore, there is interest in adequate management of the generation, conversion, storage, use and exchange of heat and electricity. The novelty of this study exists in

  8. Energy and exergy performance of residential heating systems with separate mechanical ventilation

    International Nuclear Information System (INIS)

    Zmeureanu, Radu; Yu Wu, Xin

    2007-01-01

    The paper brings new evidence on the impact of separate mechanical ventilation system on the annual energy and exergy performance of several design alternatives of residential heating systems, when they are designed for a house in Montreal. Mathematical models of residential heating, ventilation and domestic hot water (HVAC-DHW) systems, which are needed for this purpose, are developed and furthermore implemented in the Engineering Equation Solver (EES) environment. The Coefficient of Performance and the exergy efficiency are estimated as well as the entropy generation and exergy destruction of the overall system. The equivalent greenhouse gas emissions due to the on-site and off-site use of primary energy sources are also estimated. The addition of a mechanical ventilation system with heat recovery to any HVAC-DHW system discussed in the paper increases the energy efficiency; however, it decreases the exergy efficiency, which indicates a potential long-term damaging impact on the natural environment. Therefore, the use of a separate mechanical ventilation system in a house should be considered with caution, and recommended only when other means for controlling the indoor air quality cannot be applied

  9. Use of residential wood heating in a context of climate change: a population survey in Québec (Canada

    Directory of Open Access Journals (Sweden)

    Valois Pierre

    2008-05-01

    Full Text Available Abstract Background Wood heating is recommended in several countries as a climate change (CC adaptation measure, mainly to increase the autonomy of households during power outages due to extreme climatic events. The aim of this study was to examine various perceptions and individual characteristics associated with wood heating through a survey about CC adaptations. Methods A telephone survey (n = 2,545 of adults living in the southern part of the province of Québec (Canada was conducted in the early fall season of 2005. The questionnaire used closed questions and measured the respondents' beliefs and current adaptations about CC. Calibration weighting was used to adjust the data analysis for the respondent's age and language under stratified sampling based on health regions. Results More than three out of four respondents had access to a single source of energy at home, which was mainly electricity; 22.2% combined two sources or more; 18.5% heated with wood occasionally or daily during the winter. The prevalence of wood heating was higher in the peripheral regions than in the more urban regions, where there was a higher proportion of respondents living in apartments. The prevalence was also higher with participants completely disagreeing (38.5% with the eventual prohibition of wood heating when there is smog in winter, compared to respondents somewhat disagreeing (24.2% or agreeing (somewhat: 17.5%; completely: 10.4% with the adoption of this strategy. It appears that the perception of living in a region susceptible to winter smog, smog warnings in the media, or the belief in the human contribution to CC, did not influence significantly wood heating practices. Conclusion Increased residential wood heating could very well become a maladaptation to climate change, given its known consequences on winter smog and respiratory health. It would thus be appropriate to implement a long-term national program on improved and controlled residential wood

  10. Industrial and residential electricity demand dynamics in Japan: How did price and income elasticities evolve from 1989 to 2014?

    International Nuclear Information System (INIS)

    Wang, Nan; Mogi, Gento

    2017-01-01

    This study estimates the price and income elasticities of industrial and residential electricity demand in Japan with the annual data from 1989 to 2014. A time varying parameter (TVP) model with the Kalman filter is applied to monitor the evolution of consumer behaviors in the “post-bubble” period given the exogenous shock (financial crisis in 2008) and the structural breaks (electricity deregulation and Fukushima Daiichi crisis). The TVP model can provide a robust estimation of elasticities and can detect the outliers and the structural breaks. The results suggest that both industrial and residential consumers become less sensitive to price after the electricity deregulation and the financial crisis, and more sensitive to price after the Fukushima Daiichi crisis. Especially the industrial sector is less sensitive to price after the retail deregulation. By contrast, the income elasticities of industrial and residential sector consumers are stable during the examined period. Results also indicate that a negative relationship exists between the price elasticity of electricity demand and the price level of electricity after the electric sector deregulation. Some insights on the further electric sector reform and the environmental taxation in Japan are also provided. - Highlights: • A time varying parameter model is calculated with the Kalman filter. • Income elasticities are stable while price elasticities are time-varying. • Industrial sector is less sensitive to price change than residential sector. • Negative relationship between price elasticity and price level is found.

  11. Analysis of an underground electric heating system with short-term energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Ramadan, B.H. [Michigan State Univ., East Lansing, MI (United States). Dept. of Mechanical Engineering

    1994-12-31

    The principal commercially active heat storage application in which concrete is used as the storage medium is in the use of subfloor electric heaters embedded in a layer of sand. The resistance heaters are energized when utility offpeak rates are in effect. The sand bed and the concrete floor are then heated to some predetermined temperature, and the floor releases heat slowly and remains warm during the subsequent period of high demand. Analysis of the slab-heating system for varying design parameters, such as the depth of the placement of the heaters, the sand properties, the energy input, and the insulation thickness, was considered. The system was also optimized based on life-cycle costs. The suitability of using this system for heating a warehouse in four representative cities in the United States was also considered The response of the system was found to be greatly influenced by the depth of the placement of the heaters, the sand`s moisture content, and the heating strategy. Optimum insulation levels were determined for the prototypical building in all four of the representative cities. Because of the difficulty of controlling the energy release from the heating mats, this system may not be suitable for heating residential and office buildings but may be more appropriate for heating maintenance and storage facilities.

  12. An engineering economic assessment of whole-house residential wood heating in New York

    Science.gov (United States)

    Wood devices are being selected increasingly for residential space heating by households in New York State. Motivations for their use include energy independence, mitigating climate change, stimulating local economic development, and reducing exposure to high and variable fuel c...

  13. Targeting energy justice: Exploring spatial, racial/ethnic and socioeconomic disparities in urban residential heating energy efficiency

    International Nuclear Information System (INIS)

    Reames, Tony Gerard

    2016-01-01

    Fuel poverty, the inability of households to afford adequate energy services, such as heating, is a major energy justice concern. Increasing residential energy efficiency is a strategic fuel poverty intervention. However, the absence of easily accessible household energy data impedes effective targeting of energy efficiency programs. This paper uses publicly available data, bottom-up modeling and small-area estimation techniques to predict the mean census block group residential heating energy use intensity (EUI), an energy efficiency proxy, in Kansas City, Missouri. Results mapped using geographic information systems (GIS) and statistical analysis, show disparities in the relationship between heating EUI and spatial, racial/ethnic, and socioeconomic block group characteristics. Block groups with lower median incomes, a greater percentage of households below poverty, a greater percentage of racial/ethnic minority headed-households, and a larger percentage of adults with less than a high school education were, on average, less energy efficient (higher EUIs). Results also imply that racial segregation, which continues to influence urban housing choices, exposes Black and Hispanic households to increased fuel poverty vulnerability. Lastly, the spatial concentration and demographics of vulnerable block groups suggest proactive, area- and community-based targeting of energy efficiency assistance programs may be more effective than existing self-referral approaches. - Highlights: • Develops statistical model to predict block group (BG) residential heating energy use intensity (EUI), an energy efficiency proxy. • Bivariate and multivariate analyses explore racial/ethnic and socioeconomic relationships with heating EUI. • BGs with more racial/ethnic minority households had higher heating EUI. • BGs with lower socioeconomics had higher heating EUI. • Mapping heating EUI can facilitate effective energy efficiency intervention targeting.

  14. Solar heating and cooling of residential buildings: sizing, installation and operation of systems. 1980 edition

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This manual was prepared as a text for a training course on solar heating and cooling of residential buildings. The course and text are directed toward sizing, installation, operation, and maintenance of solar systems for space heating and hot water supply, and solar cooling is treated only briefly. (MHR)

  15. Electric and gas utility marketing of residential energy conservation case studies

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    The objective of this research was to obtain information about utility conservation marketing techniques from companies actively engaged in performing residential conservation services. Many utilities currently are offering comprehensive services (audits, listing of contractors and lenders, post-installation inspection, advertising, and performing consumer research). Activities are reported for the following utilities: Niagara Mohawk Power Corporation; Tampa Electric Company; Memphis Light, Gas, and Water Division; Northern States Power-Wisconsin; Public Service Company of Colorado; Arizona Public Service Company; Pacific Gas and Electric Company; Sacramento Municipal Utility District; and Pacific Power and Light Company.

  16. Optimisation of a Swedish district heating system with reduced heat demand due to energy efficiency measures in residential buildings

    International Nuclear Information System (INIS)

    Åberg, M.; Henning, D.

    2011-01-01

    The development towards more energy efficient buildings, as well as the expansion of district heating (DH) networks, is generally considered to reduce environmental impact. But the combined effect of these two progressions is more controversial. A reduced heat demand (HD) due to higher energy efficiency in buildings might hamper co-production of electricity and DH. In Sweden, co-produced electricity is normally considered to displace electricity from less efficient European condensing power plants. In this study, a potential HD reduction due to energy efficiency measures in the existing building stock in the Swedish city Linköping is calculated. The impact of HD reduction on heat and electricity production in the Linköping DH system is investigated by using the energy system optimisation model MODEST. Energy efficiency measures in buildings reduce seasonal HD variations. Model results show that HD reductions primarily decrease heat-only production. The electricity-to-heat output ratio for the system is increased for HD reductions up to 30%. Local and global CO 2 emissions are reduced. If co-produced electricity replaces electricity from coal-fired condensing power plants, a 20% HD reduction is optimal for decreasing global CO 2 emissions in the analysed DH system. - Highlights: ► A MODEST optimisation model of the Linköping district heating system is used. ► The impact of heat demand reduction on heat and electricity production is examined. ► Model results show that heat demand reductions decrease heat-only production. ► Local and global CO 2 emissions are reduced. ► The system electricity-to-heat output increases for reduced heat demand up to 30%.

  17. Market Assessment for Residential Refrigerator-Freezer with Novel Rotating Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Sikes, Karen [CSRA International, Inc., Fairfax, VA (United States); Blackburn, Julia [CSRA International, Inc., Fairfax, VA (United States); Grubbs, Tyler [CSRA International, Inc., Fairfax, VA (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Momen, Ayyoub [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-02-01

    Despite a steady record of energy efficiency improvements in residential refrigerators and freezers over recent decades, these products still account for 4% of the site energy consumption for the average U.S. household. The Oak Ridge National Laboratory (ORNL) – along with partners Sandia National Laboratories (SNL) and the University of Maryland – are pursuing further efficiency improvements in this market sector by using a novel/prototype rotating heat exchanger (RHX) based on a Sandia Cooler technology as an evaporator in a residential refrigerator-freezer. The purpose of this study is to investigate the market potential of refrigerator-freezer products equipped with RHX evaporators in the United States, including projections of maximum annual market share and unit shipments and maximum direct and indirect job creation.

  18. Solar/electric heating systems for the future energy system

    DEFF Research Database (Denmark)

    Furbo, Simon; Dannemand, Mark; Perers, Bengt

    elements/heat pump, advanced heat storage tanks and advanced control systems. Heat is produced by solar collectors in sunny periods and by electrical heating elements/heat pump. The electrical heating elements/heat pump will be in operation in periods where the heat demand cannot be covered by solar energy....... The aim is to use the auxiliary heating units when the electricity price is low, e.g. due to large electricity production by wind turbines. The unit is equipped with an advanced control system where the control of the auxiliary heating is based on forecasts of the electricity price, the heat demand...

  19. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  20. Calculating residential carbon dioxide emissions - a new approach

    International Nuclear Information System (INIS)

    Hughes, Larry; Bohan, Kathleen; Good, Joel; Jafapur, Khosrow

    2005-01-01

    All Annex 1 Parties are required to submit an annual national greenhouse gas inventory to the United Nations Framework Convention on Climate Change using the common report format. The inventory is to include a sectoral report for energy, listing different sectors and their associated greenhouse gas emissions (principally carbon dioxide, methane, and nitrous oxide). The sectors and their associated emissions can be used as a benchmark to show changes in emissions over time. In certain cases, these changes can be misleading, since an apparent emission reduction in one sector can result in a significant increase in the emissions of another, typically electricity production. Applying the emissions to the sector responsible for the final energy demand (as opposed to the sector that generates the energy) allows researchers and policy makers to develop reduction strategies that are targeted to the demand. This paper demonstrates this by removing the equivalent residential emissions from category A.1.a (Public Electricity and Heat Production) and applying them to category A.4.b (Residential) in Nova Scotia, a Canadian province that relies heavily on fossil fuels for electrical generation. The shift in emissions changes an apparent 4.1 percent decrease in Nova Scotia's residential emissions between 1991 and 2001 to an 8.2 percent increase. (Author)

  1. Modernizing residential heating in Russia: End-use practices, legal developments, and future prospects

    International Nuclear Information System (INIS)

    Korppoo, Anna; Korobova, Nina

    2012-01-01

    This article explores the significance of modernization policies concerning Russia’s technically obsolete but socially important residential heating sector, focusing on the 2009 energy efficiency framework law and its prospects for implementation. Ownership and control structures are in flux throughout the heating sector chain. Inefficiencies, causing low service quality and rising prices, have already started eroding the market share of district heating, despite its potential benefits. End-use management practices – such as lack of metering, communal billing, and low prices that do not cover production costs – reduce consumer incentives to cut consumption. The diversity of end-users adds to the complexity of focused measures like energy-saving contracts. However, end-use sector reforms such as mandatory meter installation and increasing prices – even if socially acceptable and fully implemented – cannot alone provide the massive investments required. More appropriate is sector-wide reform with the government’s financial participation – especially if consumer efforts can yield better service quality. - Highlights: ► We analyze Russia’s energy efficiency policy on residential heating sector. ► Institutional structures and practices reduce incentives to cut consumption. ► Meter installation and increasing prices cannot deliver investments required. ► Government led sector-wide reform is required, linked to better service quality.

  2. The long-run price sensitivity dynamics of industrial and residential electricity demand: The impact of deregulating electricity prices

    International Nuclear Information System (INIS)

    Adom, Philip Kofi

    2017-01-01

    This study examines the demand-side of Ghana's electricity sector. We test two important related hypotheses: (1) deregulation of electricity price does not promote energy conservation, and (2) demand-price relationship is not an inverted U-shaped. The Stock and Watson dynamic OLS is used to address the so-called second-order bias. The result showed that, deregulation of electricity price in Ghana has induced behaviours that are more consistent with energy conservation improvements. The demand-price relationship is an inverted U, which suggests that there is a price range that end-users can tolerate further price rise and still increase their consumption of electricity. However, the degree of price tolerability is higher for residential consumers than industrial consumers. The simulation results showed that, further economic growth is likely to compromise energy conservation but more in the industrial sector than the residential sector. On the other hand, future crude oil price is likely to deteriorate energy conservation in the initial years after 2016, but this trend is likely to reverse after the year 2020. Pricing mechanisms are potent to induce energy conservation but inadequate. The results suggest that they should be complemented with other stringent policies such as a mandatory energy reduction policy, investment in renewables, and personalization of energy efficiency programs. - Highlights: • Studies the demand-side of the electricity sector • Deregulating electricity price promotes energy conservation • Demand-price relationship is an inverted U-shaped • Pricing policies should be combined with other energy mandatory reduction policies

  3. Integrating a hydrogen fuel cell electric vehicle with vehicle-to-grid technology, photovoltaic power and a residential building

    NARCIS (Netherlands)

    Robledo, C.B.; Oldenbroek, V.D.W.M.; Abbruzzese, F.; van Wijk, A.J.M.

    2018-01-01

    This paper presents the results of a demonstration project, including building-integrated photovoltaic (BIPV) solar panels, a residential building and a hydrogen fuel cell electric vehicle (FCEV) for combined mobility and power generation, aiming to achieve a net zero-energy residential building

  4. The Private Net Benefits of Residential Solar PV: The Role of Electricity Tariffs, Tax Incentives and Rebates

    OpenAIRE

    Severin Borenstein

    2015-01-01

    With dramatic declines in the cost of solar PV technology over the last 5 years, the electricity industry is in the midst of discussions about whether to use this low-polluting renewable energy source in grid-scale generation or in distributed generation (DG), mostly with rooftop solar PV. California has led the growth in DG solar in the U.S. I use 2007 to early 2014 residential data from Pacific Gas & Electric – the utility with largest number of residential solar customers in the U.S. – to ...

  5. Clustering-based analysis for residential district heating data

    DEFF Research Database (Denmark)

    Gianniou, Panagiota; Liu, Xiufeng; Heller, Alfred

    2018-01-01

    The wide use of smart meters enables collection of a large amount of fine-granular time series, which can be used to improve the understanding of consumption behavior and used for consumption optimization. This paper presents a clustering-based knowledge discovery in databases method to analyze r....... These findings will be valuable for district heating utilities and energy planners to optimize their operations, design demand-side management strategies, and develop targeting energy-efficiency programs or policies.......The wide use of smart meters enables collection of a large amount of fine-granular time series, which can be used to improve the understanding of consumption behavior and used for consumption optimization. This paper presents a clustering-based knowledge discovery in databases method to analyze...... residential heating consumption data and evaluate information included in national building databases. The proposed method uses the K-means algorithm to segment consumption groups based on consumption intensity and representative patterns and ranks the groups according to daily consumption. This paper also...

  6. Did residential electricity rates fall after retail competition? A dynamic panel analysis

    International Nuclear Information System (INIS)

    Swadley, Adam; Yücel, Mine

    2011-01-01

    A key selling point for the restructuring of electricity markets was the promise of lower prices. There is not much consensus in earlier studies on the effects of electricity deregulation in the U.S., particularly for residential customers. Part of the reason for not finding a consistent link with deregulation and lower prices was that the removal of transitional price caps led to higher prices. In addition, the timing of the removal of price caps coincided with rising fuel prices, which were passed on to consumers in a competitive market. Using a dynamic panel model, we analyze the effect of participation rates, fuel costs, market size, a rate cap and switch to competition for 16 states and the District of Columbia. We find that an increase in participation rates, price controls, a larger market, and high shares of hydro in electricity generation lower retail prices, while increases in natural gas and coal prices increase rates. We also find that retail competition makes the market more efficient by lowering the markup of retail prices over wholesale costs. The effects of a competitive retail electricity market are mixed across states, but generally appear to lower prices in states with high participation rates. - Highlights: ► We analyze the effects of retail competition in electricity markets on residential retail prices. ► Analysis carried out using a dynamic panel model; monthly data for 17 U.S. states. ► More customer participation and larger market lead to lower prices. ► Higher fuel costs increase retail prices, but with a lag. ► Retail competition leads to a more efficient electricity market.

  7. Mitigation of Short-Lived Climate Pollutants from Residential Coal Heating and Combined Heating/Cooking Stoves: Impacts on the Cryosphere, Policy Options, and Co-benefits

    Science.gov (United States)

    Chafe, Z.; Anenberg, S.; Klimont, Z.; Kupiainen, K.; Lewis, J.; Metcalfe, J.; Pearson, P.

    2017-12-01

    Residential solid fuel combustion for cooking, heating, and other energy services contributes to indoor and outdoor air pollution, and creates impacts on the cryosphere. Solid fuel use often occurs in colder climates and at higher elevations, where a wide range of combustion emissions can reduce reflectivity of the snow- and ice-covered surfaces, causing climatic warming. Reducing short-lived climate pollutants (SLCPs), such as black carbon (BC), could have substantial climate and health co-benefits, especially in areas where emissions influence the cryosphere. A review of existing literature and emissions estimates, conducted as part of the Warsaw Summit on BC and Other Emissions from Residential Coal Heating Stoves and Combined Cooking/Heating Stoves, found little nationally-representative data on the fuels and technologies used for heating and combined cooking/heating. The GAINS model estimates that 24 million tonnes of coal equivalent were combusted by households for space heating globally in 2010, releasing 190 kilotons (kt) BC. Emissions from combined cooking/heating are virtually unknown. Policy instruments could mitigate cryosphere-relevant emissions of SLCPs from residential heating or cooking. These include indoor air quality guidelines, stove emission limits, bans on the use of specific fuels, regulatory codes that stipulate when burning can occur, stove changeout programs, and voluntary public education campaigns. These measures are being implemented in countries such as Chile (fuelwood moisture reduction campaign, energy efficiency, heating system improvements), Mongolia (stove renovation, fuel switching), Peru (improved stove programs), Poland (district heating, local fuel bans), United States (stove emission regulation) and throughout the European Community (Ecodesign Directive). Few, if any, of these regulations are likely to reduce emissions from combined cooking/heating. This research team found no global platform to create and share model

  8. Electric vehicles in low voltage residential grid: a danish case study

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Thøgersen, Paul

    2012-01-01

    Electric Vehicles (EVs) have gained large interest in the energy sector as a carrier to support clean transportation and green electricity. The potential to use battery storages of electric vehicles as a sink for excess electricity that may result from large integration of wind power, especially...... in countries like Denmark, is widely discussed and promoted. However, the wide-spread adoption of EVs requires the provision of intelligent grid and EV charging infrastructure. To analyse and understand the amount of EVs that could be integrated in the local distribution grids, within its existing capabilities......, is absolutely essential for the system operators to plan and implement the levels of grid reinforcement and intelligence required. This paper investigates the local grid limitations to accommodate large amount of EVs of sizable power ratings in residential areas. The case study applied in this paper uses...

  9. Comparative analysis of greenhouse gas emissions of various residential heating systems in the Canadian provinces

    International Nuclear Information System (INIS)

    Pare, D.

    2010-04-01

    The Kyoto Protocol compels signatory countries to reduce their greenhouse gas emissions by at least 5 percent by 2010 as compared to 1990 levels. In Canada, however, questions remain regarding the effects of greenhouse gases as they relate to the adoption of geoexchange systems in certain provinces because of the sources of electricity. This report presented a comprehensive analysis of the specific and strategic role of geoexchange technology, and ground source heat pumps in particular. The purpose was to compare, on a common basis, the greenhouse gas emissions of different residential heating systems utilized in the Canadian provinces. Comparisons were conducted from an environmental standpoint, and excluded the exergy and economic aspect, or other related issues. The report discussed the methodology and hypotheses of the study and presented the results for Canada, and for each province. It was concluded that according to the hypotheses employed for the purposes of this study, geoexchange systems offer a solution for greenhouse gas reduction and climatic change in all of the analyzed scenarios, with few exceptions and for a specific scenario. 32 refs., 37 tabs., 12 figs., 4 appendices.

  10. An emerging market in fuel cells? Residential combined heat and power in four countries

    International Nuclear Information System (INIS)

    Brown, J.E.; Hendry, C.N.; Harborne, P.

    2007-01-01

    Global concerns about fossil fuel stocks and security of supply have stimulated governments and industry to explore the development of alternative sources of energy. This has led to the emergence of liberalised markets for energy and the growth of de-centralised generation and distribution systems. Within this context, the use of a sustainable technology, such as fuel cells, as a generator of heat and electricity for the residential market, is a significant market opportunity. Using a set of framework conditions to explain the diffusion of renewable energy technologies, this paper analyses recent developments in four leading industrial countries, and concludes that Japan and Germany are competing to be the lead country for the introduction of this technology. In the process, we highlight the impact of government and the extent to which the development of a fuel cell industry is being driven by incumbent large firms acting independently or in collaboration with a range of other companies across the value chain. [Author

  11. An emerging market in fuel cells? Residential combined heat and power in four countries

    International Nuclear Information System (INIS)

    Brown, James E.; Hendry, Chris N.; Harborne, Paul

    2007-01-01

    Global concerns about fossil fuel stocks and security of supply have stimulated governments and industry to explore the development of alternative sources of energy. This has led to the emergence of liberalised markets for energy and the growth of de-centralised generation and distribution systems. Within this context, the use of a sustainable technology, such as fuel cells, as a generator of heat and electricity for the residential market, is a significant market opportunity. Using a set of framework conditions to explain the diffusion of renewable energy technologies, this paper analyses recent developments in four leading industrial countries, and concludes that Japan and Germany are competing to be the lead country for the introduction of this technology. In the process, we highlight the impact of government and the extent to which the development of a fuel cell industry is being driven by incumbent large firms acting independently or in collaboration with a range of other companies across the value chain

  12. Residential wood heating: The forest, the atmosphere and the public consciousness

    International Nuclear Information System (INIS)

    Gulland, J.F.; Hendrickson, O.Q.

    1993-01-01

    It is generally agreed by both energy and forestry scientists that, provided harvesting is conducted in a sustainable manner, the combustion of wood for energy production is essentially carbon dioxide neutral when the normal forest regeneration period is considered. When wood combustion replaces the consumption of fossil fuels, however, the net reduction in carbon dioxide release is almost immediate. In addition to the requirement of sustainable forestry practices, the maintenance of site biodiversity must also be considered. A preliminary review of the literature reveals that periodic selective harvesting can actually have a positive impact on the biodiversity of the forest. Despite the fact that the harvesting, processing and transportation of wood fuel invariably consumes fossil fuels, it has been shown in case studies that the energy return on investment can easily exceed a ratio of 25:1. Approximately 20 percent of the single family dwellings in Canada are heated to some extent with wood and the potential exists for an increasing contribution of wood fuel to residential energy requirements. However, there is evidence of confusion among the public regarding the environmental impact of woodburning, particularly as it relates to CO 2 emissions and carbon storage in forests. The confusion could impede the increased use of wood for residential heating because it calls into question the appropriateness of using wood for energy purposes. The forms of residential wood energy use that have evolved in rural North America provide important but neglected models of sustainable development. This could serve as the central theme of public information program to clarify the role of wood energy in the reduction of greenhouse gas emissions

  13. Development of a coal fired pulse combustor for residential space heating. Phase I, Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-04-01

    This report presents the results of the first phase of a program for the development of a coal-fired residential combustion system. This phase consisted of the design, fabrication, testing, and evaluation of an advanced pulse combustor sized for residential space heating requirements. The objective was to develop an advanced pulse coal combustor at the {approximately} 100,000 Btu/hr scale that can be integrated into a packaged space heating system for small residential applications. The strategy for the development effort included the scale down of the feasibility unit from 1-2 MMBtu/hr to 100,000 Btu/hr to establish a baseline for isolating the effect of scale-down and new chamber configurations separately. Initial focus at the residential scale was concentrated on methods of fuel injection and atomization in a bare metal unit. This was followed by incorporating changes to the advanced chamber designs and testing of refractory-lined units. Multi-fuel capability for firing oil or gas as a secondary fuel was also established. Upon completion of the configuration and component testing, an optimum configuration would be selected for integrated testing of the pulse combustor unit. The strategy also defined the use of Dry Ultrafine Coal (DUC) for Phases 1 and 2 of the development program with CWM firing to be a product improvement activity for a later phase of the program.

  14. Residential consumers in the Cape Peninsula's willingness to pay for premium priced green electricity

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, Henry; Volschenk, Jako; Smit, Eon [University of Stellenbosch Business School, Carl Cronje Drive, Bellville, Western Cape 7535 (South Africa)

    2011-02-15

    A number of studies have explored the willingness (i.e. stated willingness as opposed to actual willingness) of consumers to pay a premium for green electricity in developed countries. However, little is known about how this translates into an emerging economy context. This study investigates the level of willingness of residential households in South Africa's Cape Peninsula to pay a premium for electricity from renewable energy. It methodologically drew on recent contributions in the literature on norm-motivated behaviour used to identify testable factors that could influence residential consumers' willingness to pay (WTP). Interestingly, the study found a significant positive link between household income and WTP for green electricity, contrary to the findings of some previous studies. Not only are higher income households more likely to pay a premium, but typically they are also willing to pay a bigger premium. It was also further established that the view that green electricity is reliable, involvement in the recycling of waste and the belief that everyone should contribute to green electricity generation drive the WTP. (author)

  15. Electrically heated DPF start-up strategy

    Science.gov (United States)

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2012-04-10

    An exhaust system that processes exhaust generated by an engine has a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates in the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates. Heat generated by combustion of particulates in the heater induces combustion of particulates within the DPF. A control module selectively enables current flow to the electrical heater for an initial period of a DPF regeneration cycle, and limits exhaust flow while the electrical heater is heating to a predetermined soot combustion temperature.

  16. Heat operated cryogenic electrical generator

    International Nuclear Information System (INIS)

    Fletcher, J.C.; Wang, T.C.; Saffren, M.M.; Elleman, D.D.

    1975-01-01

    An electrical generator useful for providing electrical power in deep space, is disclosed. The subject electrical generator utilizes the unusual hydrodynamic property exhibited by liquid helium as it is converted to and from a superfluid state to cause opposite directions of rotary motion for a rotor cell thereof. The physical motion of said rotor cell is employed to move a magnetic field provided by a charged superconductive coil mounted on the exterior of said cell. An electrical conductor is placed in surrounding proximity to said cell to interact with the moving magnetic field provided by the superconductive coil and thereby generate electrical energy. A heat control arrangement is provided for the purpose of causing the liquid helium to be partially converted to and from a superfluid state by being cooled and heated, respectively. (U.S.)

  17. Integration of plug-in hybrid electric vehicles (PHEV) with grid connected residential photovoltaic energy systems

    Science.gov (United States)

    Nagarajan, Adarsh; Shireen, Wajiha

    2013-06-01

    This paper proposes an approach for integrating Plug-In Hybrid Electric Vehicles (PHEV) to an existing residential photovoltaic system, to control and optimize the power consumption of residential load. Control involves determining the source from which residential load will be catered, where as optimization of power flow reduces the stress on the grid. The system built to achieve the goal is a combination of the existing residential photovoltaic system, PHEV, Power Conditioning Unit (PCU), and a controller. The PCU involves two DC-DC Boost Converters and an inverter. This paper emphasizes on developing the controller logic and its implementation in order to accommodate the flexibility and benefits of the proposed integrated system. The proposed controller logic has been simulated using MATLAB SIMULINK and further implemented using Digital Signal Processor (DSP) microcontroller, TMS320F28035, from Texas Instruments

  18. Assessment of infiltration heat recovery and its impact on energy consumption for residential buildings

    International Nuclear Information System (INIS)

    Solupe, Mikel; Krarti, Moncef

    2014-01-01

    Highlights: • Five steady-state air infiltration heat recovery or IHR models are described and compared. • IHR models are incorporated within whole-building simulation analysis tool. • IHR can reduce the thermal loads of residential buildings by 5–30%. - Abstract: Infiltration is a major contributor to the energy consumption of buildings, particularly in homes where it accounts for one-third of the heating and cooling loads. Traditionally, infiltration is calculated independent of the building envelope performance, however, it has been established that a thermal coupling exists between the infiltration and conduction heat transfer of the building envelope. This effect is known as infiltration heat recovery (IHR). Experiments have shown that infiltration heat recovery can typically reduce the infiltration thermal load by 10–20%. Currently, whole-building energy simulation tools do not account for the effect of infiltration heat recovery on heating and cooling loads. In this paper, five steady-state IHR models are described to account for the thermal interaction between infiltration air and building envelope components. In particular, inter-model and experimental comparisons are carried out to assess the prediction accuracy of five IHR models. In addition, the results from a series of sensitivity analyses are presented, including an evaluation of the predictions for heating energy use associated with four audited homes obtained from whole-building energy simulation analysis with implemented infiltration heat recovery models. Experimental comparison of the IHR models reveal that the predictions from all the five models are consistent and are within 2% when 1-D flow and heat transfer conditions are considered. When implementing IHR models to a whole-building simulation environment, a reduction of 5–30% in heating consumption is found for four audited residential homes

  19. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems

  20. Estimation of European Union residential sector space cooling potential

    International Nuclear Information System (INIS)

    Jakubcionis, Mindaugas; Carlsson, Johan

    2017-01-01

    Data on European residential space cooling demands are scarce and often of poor quality. This can be concluded from a review of the Comprehensive Assessments on the energy efficiency potential in the heating and cooling sector performed by European Union Member States under Art. 14 of the Energy Efficiency Directive. This article estimates the potential space cooling demands in the residential sector of the EU and the resulting impact on electricity generation and supply systems using the United States as a proxy. A georeferenced approach was used to establish the potential residential space cooling demand in NUTS-3 regions of EU. The total potential space cooling demand of the EU was estimated to be 292 TW h for the residential sector in an average year. The additional electrical capacity needed was estimated to 79 GW. With proper energy system development strategies, e.g. matching capacity of solar PV with cooling demand, or introduction of district cooling, the stresses on electricity system from increasing cooling demand can be mitigated. The estimated potential of space cooling demand, identified in this paper for all EU Members States, could be used while preparing the next iteration of EU MS Comprehensive Assessments or other energy related studies. - Highlights: • An estimation of EU space cooling demand potential in residential sector is presented. • An estimate of space cooling demand potential is based on using USA data as a proxy. • Significant cooling demand increase can be expected. • Cooling demand increase would lead to increased stress in energy supply systems. • Proper policies and strategies might measurably decrease the impact on energy systems.

  1. The demand function for residential heat through district heating system and its consumption benefits in Korea

    International Nuclear Information System (INIS)

    Lim, Seul-Ye; Kim, Hyo-Jin; Yoo, Seung-Hoon

    2016-01-01

    The demand for residential heat (RH) through a district heating system (DHS) has been and will be expanded in Korea due to its better performance in energy efficiency and the abatement of greenhouse gas emissions than decentralized boilers. The purposes of this paper are two-fold. The first is to obtain the demand function for DHS-based RH in Korea and investigate the price and income elasticities of the demand employing the quarterly data covering the period 1988–2013. The short-run price and income elasticities are estimated as −0.700 and 0.918, respectively. Moreover, the long-run elasticities are −1.253 and 1.642, respectively. The second purpose is to measure the consumption benefits of DHS-based-RH employing the economic theory that they are the sum of the actual payment and consumer surplus for the consumption. Considering that the average price and estimated consumer surplus of the DHS-based RH use in 2013 are computed to be KRW 87,870 (USD 84.1) and KRW 62,764 (USD 60.1) per Gcal, the consumption benefits of the DHS-based RH are calculated to be KRW 150,634 (USD 144.2) per Gcal. This information can be beneficially utilized to conduct an economic feasibility study for a new DHS project related to RH supply. - Highlights: • Demand for residential heat (RH) from district heating system (DHS) is expanding. • We estimate the demand function for and consumption benefits of DHS-based RH. • Short-run price and income elasticities are −0.700 and 0.918, respectively. • Long-run price and income elasticities are −1.253 and 1.642, respectively. • Consumption benefits of DHS-based RH are KRW 150,634 (USD 144.2) per Gcal.

  2. Analysis and modeling of active occupancy of the residential sector in Spain: An indicator of residential electricity consumption

    International Nuclear Information System (INIS)

    López-Rodríguez, M.A.; Santiago, I.; Trillo-Montero, D.; Torriti, J.; Moreno-Munoz, A.

    2013-01-01

    The growing energy consumption in the residential sector represents about 30% of global demand. This calls for Demand Side Management solutions propelling change in behaviors of end consumers, with the aim to reduce overall consumption as well as shift it to periods in which demand is lower and where the cost of generating energy is lower. Demand Side Management solutions require detailed knowledge about the patterns of energy consumption. The profile of electricity demand in the residential sector is highly correlated with the time of active occupancy of the dwellings; therefore in this study the occupancy patterns in Spanish properties was determined using the 2009–2010 Time Use Survey (TUS), conducted by the National Statistical Institute of Spain. The survey identifies three peaks in active occupancy, which coincide with morning, noon and evening. This information has been used to input into a stochastic model which generates active occupancy profiles of dwellings, with the aim to simulate domestic electricity consumption. TUS data were also used to identify which appliance-related activities could be considered for Demand Side Management solutions during the three peaks of occupancy. -- Highlights: •Active occupancy profiles of Spanish dwellings has been obtained and modeled from Time Use Survey data. •Occupancy profiles resulting from the model can be used to model domestic energy consumption. •The presence of three peaks of active occupation was verified, which coincide with morning, noon and evening. •Manual and incentive-based DSM programmes are considered the most suitable for Spanish dwellings. •TV electricity consumption becomes important at aggregate level

  3. Optimized Energy Management of a Single-House Residential Micro-Grid With Automated Demand Response

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Monsef, Hassan; Rahimi-Kian, Ashkan

    2015-01-01

    In this paper, an intelligent multi-objective energy management system (MOEMS) is proposed for applications in residential LVAC micro-grids where households are equipped with smart appliances, such as washing machine, dishwasher, tumble dryer and electric heating and they have the capability...

  4. Energy statistics for non-residential premises in 2001

    International Nuclear Information System (INIS)

    2002-01-01

    The dominating heating system in premises is district heating, 56 per cent of the surface area is heated that way. Oil is used for heating in 9 per cent of the surface area and about the same area is heated by electricity only. The total surface area for premises is about 138 million square metres in 2001. Since the beginning of the 1980s the surface area of offices has been increasing and is now about 33 million square metres. As an average the energy use is: 15.5 litres of oil/m 2 ; 139 kWh/m 2 district heating; 148 kWh/m 2 electricity. All together the use is: 309,000 m 3 oil, 12.4 TWh district heating; 3.5 TWh electricity; 0.5 TWh natural gas/gaswork gas; 0.4 TWh o ther furnace ; 0.4 TWh biofuel or peat. This survey covers non-residential premises in Sweden. It is based on a sample of 8228 properties built before 2001 and on a total survey of properties owned by some of the major owners in the country (about 1700 properties). The survey was carried out in February 2002 as a mail survey. The property owners were asked to give information about type of premises, type of heating system, deliveries of energy for heating, etc. The presentation gives data on deliveries of energy, heated surface area, average consumption, etc., for the total population and for various subdivisions

  5. Solar heating and cooling of residential buildings: design of systems, 1980 edition

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-09-01

    This manual was prepared primarily for use in conducting a practical training course on the design of solar heating and cooling systems for residential and small office buildings, but may also be useful as a general reference text. The content level is appropriate for persons with different and varied backgrounds, although it is assumed that readers possess a basic understanding of heating, ventilating, and air-conditioning systems of conventional (non-solar) types. This edition is a revision of the manual with the same title, first printed and distributed by the US Government Printing Office in October 1977. The manual has been reorganized, new material has been added, and outdated information has been deleted. Only active solar systems are described. Liquid and air-heating solar systems for combined space and service water heating or service water heating are included. Furthermore, only systems with proven experience are discussed to any extent.

  6. Solar/electric heating systems for the future energy system

    Energy Technology Data Exchange (ETDEWEB)

    Furbo, S.; Dannemand, M.; Perers, B. [and others

    2013-05-15

    The aim of the project is to elucidate how individual heating units for single family houses are best designed in order to fit into the future energy system. The units are based on solar energy, electrical heating elements/heat pump, advanced heat storage tanks and advanced control systems. Heat is produced by solar collectors in sunny periods and by electrical heating elements/heat pump. The electrical heating elements/heat pump will be in operation in periods where the heat demand cannot be covered by solar energy. The aim is to use the auxiliary heating units when the electricity price is low, e.g. due to large electricity production by wind turbines. The unit is equipped with an advanced control system where the control of the auxiliary heating is based on forecasts of the electricity price, the heat demand and the solar energy production. Consequently, the control is based on weather forecasts. Three differently designed heating units are tested in a laboratory test facility. The systems are compared on the basis of: 1) energy consumption for the auxiliary heating; 2) energy cost for the auxiliary heating; 3) net utilized solar energy. Starting from a normal house a solar combi system (for hot water and house heating) can save 20-30% energy cost, alone, depending on sizing of collector area and storage volume. By replacing the heat storage with a smart tank based on electric heating elements and a smart control based on weather/load forecast and electricity price information 24 hours ahead, another 30-40% can be saved. That is: A solar heating system with a solar collector area of about 10 m{sup 2}, a smart tank based on electric heating element and a smart control system, can reduce the energy costs of the house by at least 50%. No increase of heat storage volume is needed to utilize the smart control. The savings in % are similar for different levels of building insulation. As expected a heat pump in the system can further reduce the auxiliary electricity

  7. Residential demand response reduces air pollutant emissions on peak electricity demand days in New York City

    International Nuclear Information System (INIS)

    Gilbraith, Nathaniel; Powers, Susan E.

    2013-01-01

    Many urban areas in the United States have experienced difficulty meeting the National Ambient Air Quality Standards (NAAQS), partially due to pollution from electricity generating units. We evaluated the potential for residential demand response to reduce pollutant emissions on days with above average pollutant emissions and a high potential for poor air quality. The study focused on New York City (NYC) due to non-attainment with NAAQS standards, large exposed populations, and the existing goal of reducing pollutant emissions. The baseline demand response scenario simulated a 1.8% average reduction in NYC peak demand on 49 days throughout the summer. Nitrogen oxide and particulate matter less than 2.5 μm in diameter emission reductions were predicted to occur (−70, −1.1 metric tons (MT) annually), although, these were not likely to be sufficient for NYC to meet the NAAQS. Air pollution mediated damages were predicted to decrease by $100,000–$300,000 annually. A sensitivity analysis predicted that substantially larger pollutant emission reductions would occur if electricity demand was shifted from daytime hours to nighttime hours, or the total consumption decreased. Policies which incentivize shifting electricity consumption away from periods of high human and environmental impacts should be implemented, including policies directed toward residential consumers. - Highlights: • The impact of residential demand response on air emissions was modeled. • Residential demand response will decrease pollutant emissions in NYC. • Emissions reductions occur during periods with high potential for poor air quality. • Shifting demand to nighttime hours was more beneficial than to off-peak daytime hours

  8. Residential consumers in the Cape Peninsula's willingness to pay for premium priced green electricity

    International Nuclear Information System (INIS)

    Oliver, Henry; Volschenk, Jako; Smit, Eon

    2011-01-01

    A number of studies have explored the willingness (i.e. stated willingness as opposed to actual willingness) of consumers to pay a premium for green electricity in developed countries. However, little is known about how this translates into an emerging economy context. This study investigates the level of willingness of residential households in South Africa's Cape Peninsula to pay a premium for electricity from renewable energy. It methodologically drew on recent contributions in the literature on norm-motivated behaviour used to identify testable factors that could influence residential consumers' willingness to pay (WTP). Interestingly, the study found a significant positive link between household income and WTP for green electricity, contrary to the findings of some previous studies. Not only are higher income households more likely to pay a premium, but typically they are also willing to pay a bigger premium. It was also further established that the view that green electricity is reliable, involvement in the recycling of waste and the belief that everyone should contribute to green electricity generation drive the WTP. - Research Highlights: →The study explored the drivers of willingness to pay (WTP) a premium for green electricity. →All the hypothesised drivers of WTP a premium were found to be significant. →Contrary to some former studies, income was found to be a good predictor of WTP and the pledged premium. →The quantum of the premium positively correlates with income levels.

  9. Forecasting the adoption of residential ductless heat pumps

    International Nuclear Information System (INIS)

    Hlavinka, Alexander N.; Mjelde, James W.; Dharmasena, Senarath; Holland, Christine

    2016-01-01

    Energy-efficient technologies have the potential to provide savings to households and utilities, but consumers do not always adopt these innovations over traditional technologies. The ductless heat pump (DHP) is one such technology designed to increase energy efficiency and comfort in space conditioning. DHP adoption by single-family residences in the Pacific Northwest of the United States is investigated by quantifying the effects of utility-provided rebates and expenditures on activities such as advertising and installer training on the number of installations and forecasting installations through 2018. The number of installations is elastic with respect to net installation costs and inelastic with respect to expenditures. Given the proposed rebate budgets, doubling the current rebate is necessary to maximize installations through 2018. - Highlights: • The ductless heat pump (DHP) is an energy-efficient form of space conditioning. • Rebate and marketing programs designed to increase adoptions of DHPs are examined. • Residential adoption of DHPs is sensitive to rebates and tax credits. • Advertising and training have a smaller effect on adoption than rebates.

  10. Forecasted electric power demands for the Baltimore Gas and Electric Company. Volume 1 and Volume 2. Documentation manual

    International Nuclear Information System (INIS)

    Estomin, S.L.; Beach, J.E.; Goldsmith, J.V.

    1991-05-01

    The two-volume report presents the results of an econometric forecast of peak load and electric power demand for the Baltimore Gas and Electric Company (BG ampersand E) through the year 2009. Separate energy sales models were estimated for residential sales in Baltimore City, residential sales in the BG ampersand E service area excluding Baltimore City, commercial sales, industrial sales, streetlighting sales, and Company use plus losses. Econometric equations were also estimated for electric space heating and air conditioning saturation in Baltimore City and in the remainder of the BG ampersand E service territory. In addition to the energy sales models and the electric space conditioning saturation models, econometric models of summer and winter peak demand on the BG ampersand E system were estimated

  11. Customer-economics of residential photovoltaic systems (Part 1): The impact of high renewable energy penetrations on electricity bill savings with net metering

    International Nuclear Information System (INIS)

    Darghouth, Naïm R.; Barbose, Galen; Wiser, Ryan H.

    2014-01-01

    Residential photovoltaic (PV) systems in the US are often compensated at the customer's underlying retail electricity rate through net metering. Given the uncertainty in future retail rates and the inherent links between rates and the customer–economics of behind-the-meter PV, there is growing interest in understanding how potential changes in rates may impact the value of bill savings from PV. In this article, we first use a production cost and capacity expansion model to project California hourly wholesale electricity market prices under two potential electricity market scenarios, including a reference and a 33% renewables scenario. Second, based on the wholesale electricity market prices generated by the model, we develop retail rates (i.e., flat, time-of-use, and real-time pricing) for each future scenario based on standard retail rate design principles. Finally, based on these retail rates, the bill savings from PV is estimated for 226 California residential customers under two types of net metering, for each scenario. We find that high renewable penetrations can drive substantial changes in residential retail rates and that these changes, together with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV. - Highlights: • We investigate the impact of high renewables on customer economics of solar. • We model three types of residential retail electricity rates. • Based on the rates, we calculate the bill savings from photovoltaic (PV) generation. • High renewables penetration can lead to lower bill savings with time-varying rates. • There is substantial uncertainty in the future bill savings from residential PV

  12. A Case Study in Market Transformation for Residential Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Building Technologies Office

    2017-09-01

    This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.

  13. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  14. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  15. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norfolk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norfolk, CT (United States)

    2016-02-05

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  16. Heat pump and PV impact on residential low-voltage distribution grids as a function of building and district properties

    International Nuclear Information System (INIS)

    Protopapadaki, Christina; Saelens, Dirk

    2017-01-01

    Highlights: • Comprehensive method includes variability in building and feeder characteristics. • Detailed, 10-min, Modelica-based simulation of buildings, heat pumps and networks. • Overloading and voltage issues appear from 30% heat pumps in rural Belgian feeders. • Analysis of load profiles reveals great impact of heat pump back-up heaters. • High correlation of building neighborhood properties with grid impact indicators. - Abstract: Heating electrification powered by distributed renewable energy generation is considered among potential solutions towards mitigation of greenhouse gas emissions. Roadmaps propose a wide deployment of heat pumps and photovoltaics in the residential sector. Since current distribution grids are not designed to accommodate these loads, potential benefits of such policies might be compromised. However, in large-scale analyses, often grid constraints are neglected. On the other hand, grid impact of heat pumps and photovoltaics has been investigated without considering the influence of building characteristics. This paper aims to assess and quantify in a probabilistic way the impact of these technologies on the low-voltage distribution grid, as a function of building and district properties. The Monte Carlo approach is used to simulate an assortment of Belgian residential feeders, with varying size, cable type, heat pump and PV penetration rates, and buildings of different geometry and insulation quality. Modelica-based models simulate the dynamic behavior of both buildings and heating systems, as well as three-phase unbalanced loading of the network. Additionally, stochastic occupant behavior is taken into account. Analysis of neighborhood load profiles puts into perspective the importance of demand diversity in terms of building characteristics and load simultaneity, highlighting the crucial role of back-up electrical loads. It is shown that air-source heat pumps have a greater impact on the studied feeders than PV, in terms

  17. Side-by-Side Testing of Water Heating Systems: Results from the 2013-2014 Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States). Bulding America Partnership for Improved Residential Construction

    2017-07-12

    The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

  18. Combined heat and power generation with fuel cells in residential buildings in the future energy system; Kraft-Waerme-Kopplung mit Brennstoffzellen in Wohngebaeuden im zukuenftigen Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Jungbluth, C.H.

    2007-04-27

    Combined heat and power generation (CHP) is regarded as one of the cornerstones of a future sustainable energy system. The application of this approach can be substantially extended by employing fuel cell technologies in small units for supplying heat to residential buildings. This could create an additional market for combined heat and power generation corresponding to approx. 25% of the final energy demand in Germany today. In parallel, the extensive application of distributed fuel cell systems in residential buildings would have substantial effects on energy infrastructures, primary energy demand, the energy mix and greenhouse gas emissions. It is the aim of the present study to quantify these effects via scenario modelling of energy demand and supply for Germany up to the year 2050. Two scenarios, reference and ecological commitment, are set up, and the application and operation of fuel cell plants in the future stock of residential buildings is simulated by a bottom-up approach. A model of the building stock was developed for this purpose, consisting of 213 types of reference buildings, as well as detailed simulation models of the plant operation modes. The aim was, furthermore, to identify economically and ecologically optimised plant designs and operation modes for fuel cells in residential buildings. Under the assumed conditions of the energy economy, economically optimised plant sizes for typical one- or two-family homes are in the range of a generating capacity of a few hundred watts of electrical power. Plant sizes of 2 to 4.7 kW{sub el} as discussed today are only economically feasible in multifamily dwellings. The abolition of the CHP bonus reduces profitability, especially for larger plants operated by contractors. In future, special strategies for power generation and supply can be an economically useful addition for the heat-oriented operation mode of fuel cells. On the basis of the assumed conditions of the energy economy, a technical potential for

  19. 76 FR 63211 - Energy Efficiency Program: Test Procedures for Residential Water Heaters, Direct Heating...

    Science.gov (United States)

    2011-10-12

    ... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2011-BT-TP-0042] RIN 1904-AC53 Energy Efficiency Program: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool Heaters AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Request for...

  20. Dynamic management of integrated residential energy systems

    Science.gov (United States)

    Muratori, Matteo

    This study combines principles of energy systems engineering and statistics to develop integrated models of residential energy use in the United States, to include residential recharging of electric vehicles. These models can be used by government, policymakers, and the utility industry to provide answers and guidance regarding the future of the U.S. energy system. Currently, electric power generation must match the total demand at each instant, following seasonal patterns and instantaneous fluctuations. Thus, one of the biggest drivers of costs and capacity requirement is the electricity demand that occurs during peak periods. These peak periods require utility companies to maintain operational capacity that often is underutilized, outdated, expensive, and inefficient. In light of this, flattening the demand curve has long been recognized as an effective way of cutting the cost of producing electricity and increasing overall efficiency. The problem is exacerbated by expected widespread adoption of non-dispatchable renewable power generation. The intermittent nature of renewable resources and their non-dispatchability substantially limit the ability of electric power generation of adapting to the fluctuating demand. Smart grid technologies and demand response programs are proposed as a technical solution to make the electric power demand more flexible and able to adapt to power generation. Residential demand response programs offer different incentives and benefits to consumers in response to their flexibility in the timing of their electricity consumption. Understanding interactions between new and existing energy technologies, and policy impacts therein, is key to driving sustainable energy use and economic growth. Comprehensive and accurate models of the next-generation power system allow for understanding the effects of new energy technologies on the power system infrastructure, and can be used to guide policy, technology, and economic decisions. This

  1. Next-generation heat pump systems in residential buildings and commercial premises; Naesta generations vaermepumpssystem i bostaeder och lokaler

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Lindahl, Markus; Alsbjer, Markus; Nordman, Roger; Rolfsman, Lennart; Axell, Monica

    2009-07-01

    Summarising, the following conclusions can be drawn from this work. - Installation of a heat pump system is a very efficient way of reducing a building's energy demand without making any greater changes to the building's climate screen, and can therefore assist Sweden's achievement of its energy efficiency improvement targets. - A new generation of cost-effective smaller heat pumps is needed for installation in new detached houses or those being renovated and upgraded. - There also seems to be an excellent market potential for heat pumps that are larger than has previously been common: there should be good prospects for selling them for use in apartment buildings and in commercial or similar premises. - Heat pump installations are particularly competitive in applications where there are simultaneous heating and cooling demands in the property, and also in those cases where heating is required for most of the year and cooling for some other part of the year. If these suggested system arrangements are to be fully realised, there will be a need for further research in certain cases. Particularly, there is a need for research and development of more efficient pumps, fans and speed-controlled compressors in order to get such products on to the market. Performance measurements and follow-up of real systems are needed in order to obtain a clear picture of the efficiency of both present-day and proposed systems. This knowledge is essential for further development of systems, not only for residential buildings but also, even more importantly, for commercial and similar premises. Actual heating and cooling requirements in different types of non-residential premises need to be known more accurately in order to decide how systems should be controlled in order to minimise total energy use. Much indicates that future detached houses will be more energy-efficient, which could have the undesirable result of greater use of direct electric heating, as the investment

  2. Stochastic analysis of residential micro combined heat and power system

    DEFF Research Database (Denmark)

    Karami, H.; Sanjari, M. J.; Gooi, H. B.

    2017-01-01

    In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm...... algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected...

  3. Analysis of heat source selection for residential buildings in rural areas

    OpenAIRE

    Szul Tomasz

    2018-01-01

    The research aiming to check whether the output of currently installed boilers matches the use requirements together with estimation of their energy efficiency was carried out on a group of 84 single-family residential buildings located in rural areas. Heating and hot water energy needs were calculated for each building in order to determine the use requirements. This enabled verification whether the currently installed boilers match the actual use requirements in the buildings. Based on the ...

  4. Is an all-electric society possible? BIP-Enerpresse debate, July 7, 2009

    International Nuclear Information System (INIS)

    2009-01-01

    This paper is a synthesis of a debate where interveners were asked whether an all-electric society was desirable or possible. According to them, the share of electricity will increase, notably under the influence of developing countries. They comment the possible evolutions of the energy mix, the development of electric vehicles, and the transfer towards electricity in several sectors (transport, industry, and building) by giving up fossil energies. They outline the problem of storage of electricity, particularly in the perspective of the development of electric vehicles. Some other issues are discussed like the reduction of the residential energy consumption, the renewing of residential fuel heating systems

  5. TRANSIENT AND STEADY STATE STUDY OF PURE AND MIXED REFRIGERANTS IN A RESIDENTIAL HEAT PUMP

    Science.gov (United States)

    The report gives results of an experimental and theoretical investigation of the transient and steady state performance of a residential air-conditioning/heat pump (AC/HP) operating with different refrigerants. (NOTE: The project was motivated by environmental concerns related to...

  6. Simulation and energy analysis of distributed electric heating system

    Science.gov (United States)

    Yu, Bo; Han, Shenchao; Yang, Yanchun; Liu, Mingyuan

    2018-02-01

    Distributed electric heating system assistssolar heating systemby using air-source heat pump. Air-source heat pump as auxiliary heat sourcecan make up the defects of the conventional solar thermal system can provide a 24 - hour high - efficiency work. It has certain practical value and practical significance to reduce emissions and promote building energy efficiency. Using Polysun software the system is simulated and compared with ordinary electric boiler heating system. The simulation results show that upon energy request, 5844.5kW energy is saved and 3135kg carbon - dioxide emissions are reduced and5844.5 kWhfuel and energy consumption is decreased with distributed electric heating system. Theeffect of conserving energy and reducing emissions using distributed electric heating systemis very obvious.

  7. Impact of residential PV adoption on Retail Electricity Rates

    International Nuclear Information System (INIS)

    Cai, Desmond W.H.; Adlakha, Sachin; Low, Steven H.; De Martini, Paul; Mani Chandy, K.

    2013-01-01

    The price of electricity supplied from home rooftop photo voltaic (PV) solar cells has fallen below the retail price of grid electricity in some areas. A number of residential households have an economic incentive to install rooftop PV systems and reduce their purchases of electricity from the grid. A significant portion of the costs incurred by utility companies are fixed costs which must be recovered even as consumption falls. Electricity rates must increase in order for utility companies to recover fixed costs from shrinking sales bases. Increasing rates will, in turn, result in even more economic incentives for customers to adopt rooftop PV. In this paper, we model this feedback between PV adoption and electricity rates and study its impact on future PV penetration and net-metering costs. We find that the most important parameter that determines whether this feedback has an effect is the fraction of customers who adopt PV in any year based solely on the money saved by doing so in that year, independent of the uncertainties of future years. These uncertainties include possible changes in rate structures such as the introduction of connection charges, the possibility of PV prices dropping significantly in the future, possible changes in tax incentives, and confidence in the reliability and maintainability of PV. -- Highlights: •Households who install PV reduce their electricity consumption from the grid. •Electricity rates must increase for utility companies to recover its fixed costs. •However, higher electricity rates give households more incentives to adopt PV. •We find that this feedback has significant impact on PV uptake only in later years. •Utility companies could lose a significant fraction of high consumption customers

  8. Massive coordination of residential embedded electricity generation and demand response using the PowerMatcher approach

    International Nuclear Information System (INIS)

    Kamphuis, I.G.; Hommelberg, M.P.F.; Warmer, C.J.; Kok, J.K.

    2007-01-01

    Different driving forces push the electricity production towards decentralization. The projected increase of distributed power generation on the residential level with an increasing proportion of intermittent renewable energy resources poses problems for continuously matching the energy balance when coordination takes place centrally. On the other hand, new opportunities arise by intelligent clustering of generators and demand in so-called Virtual Power Plants. Part of the responsibility for new coordination mechanisms, then, has to be laid locally. To achieve this, the current electricity infrastructure is expected to evolve into a network of networks (including ICT (Information and Communication Technology)-networks), in which all system parts communicate with one another, are aware of each other's context and may influence each other. In this paper, a multi-agent systems approach, using price signal-vectors from an electronic market is presented as an appropriate technology needed for massive control and coordination tasks in these future electricity networks. The PowerMatcher, a market-based control concept for supply and demand matching (SDM) in electricity networks, is discussed. The results within a simulation study show the ability to raise the simultaneousness of electricity production and consumption within (local) control clusters with cogeneration and heat-pumps by exchanging price signals and coordinated allocation using market algorithms. The control concept, however, can also be applied in other business cases like reduction of imbalance cost in commercial portfolios or virtual power plant operators, utilizing distributed generators. Furthermore, a PowerMatcher-based field test configuration with 15 Stirling-engine powered micro-CHP's is described, which is currently in operation within a field test in the Netherlands

  9. Integration of Solar Photovoltaics and Electric Vehicles in Residential Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Huang, Shaojun; Bak-Jensen, Birgitte

    2013-01-01

    In the last few years, there is an increased penetration of solar photovoltaic (SPV) units in low voltage (LV) distribution grids. Also electric vehicles (EVs) are introduced to these LV networks. This has caused the distribution networks to be more active and complex as these local generation...... and load units are characterised by unpredictable and diverse operating characteristics. This paper analyses the combined effect of SPVs and EVs in LV Danish residential grids. The EVs charging needs based on typical driving patterns of passenger cars and SPV power profiles during winter/summer days...

  10. Interotex-innovative gas equipment for heating and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Winnington, T.L. [Interotex Ltd. (United Kingdom); Moore, N. [British Gas plc (United Kingdom); Valle, F.; Sanz, J. I. [Gas Natural SDG S.A. (Spain); Chavarri, J.M. [Fagor Electrodomesticos S. Coop. (Spain); Uselton, R. [Lennox Industries Inc. (United States)

    1997-10-01

    Conventionally, cooling technology for the residential market is provided by electrically driven vapour re-compression systems. But lately, due to the Montreal Protocol - restricting the utilisation of ozone depleting substances - and to the high peak demand in electricity, created by electrical air conditioning systems, there is a commercial opportunity for gas fired air conditioning appliances. This paper describes the development programme for a radical new absorption technology, from the theoretical studies, through the experimental programme, to the building, commissioning and installation of demonstration machines. It also includes an analysis of the world-wide residential cooling market and the opportunities available to manufacturers and gas utilities to introduce new gas heating and cooling technology, capable of competing effectively with electrical systems. (au)

  11. A critical look at residential electricity conservation campaigns in a developing country environment

    International Nuclear Information System (INIS)

    Martino Jannuzzi, G. de; Ferreira Santos, V. dos

    1993-01-01

    This paper analyse survey results of the effectiveness of information campaigns to promote energy efficiency among residential consumers in Brazil. The survey found that consumers have a relatively good knowledge of conservation measures to improve electricity usage. Nevertheless, other approaches are needed to promote energy conservation in the household sector. (author). 3 refs, 4 figs, 2 tabs

  12. Developing a Mixed Neural Network Approach to Forecast the Residential Electricity Consumption Based on Sensor Recorded Data.

    Science.gov (United States)

    Oprea, Simona-Vasilica; Pîrjan, Alexandru; Căruțașu, George; Petroșanu, Dana-Mihaela; Bâra, Adela; Stănică, Justina-Lavinia; Coculescu, Cristina

    2018-05-05

    In this paper, we report a study having as a main goal the obtaining of a method that can provide an accurate forecast of the residential electricity consumption, refining it up to the appliance level, using sensor recorded data, for residential smart homes complexes that use renewable energy sources as a part of their consumed electricity, overcoming the limitations of not having available historical meteorological data and the unwillingness of the contractor to acquire such data periodically in the future accurate short-term forecasts from a specialized institute due to the implied costs. In this purpose, we have developed a mixed artificial neural network (ANN) approach using both non-linear autoregressive with exogenous input (NARX) ANNs and function fitting neural networks (FITNETs). We have used a large dataset containing detailed electricity consumption data recorded by sensors, monitoring a series of individual appliances, while in the NARX case we have also used timestamps datasets as exogenous variables. After having developed and validated the forecasting method, we have compiled it in view of incorporating it into a cloud solution, being delivered to the contractor that can provide it as a service for a monthly fee to both the operators and residential consumers.

  13. Study on tariffs for heat pumps

    International Nuclear Information System (INIS)

    Dieleman, M.; Hellemans, J.G.; Bouvy, E.J.; Van de Molen, B.A.

    1996-07-01

    An overview is given of the impact of electricity prices on the economic feasibility of electrical heat pumps for the residential sector, utility buildings, horticulture, and the industry in the Netherlands. The financial feasibility is calculated for three scenarios: low (present situation in the Netherlands), medium (short-term situation, 1998-2000, and more favtoable compared to the low scenario) and high (even more favorable conditions for the expected future situation after the year 2000 in case of a large-scale application of heat pumps). 25 figs., 25 tabs., 10 appendices, 46 refs

  14. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently re-emerged on the U.S. market, and they have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine the actual energy consumption of a HPWH in different U.S. regions, annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the United States. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  15. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains a minimum of 70 citations and includes a subject term index and title list.)

  16. The residential demand for electricity in Australia: an application of the bounds testing approach to cointegration

    International Nuclear Information System (INIS)

    Narayan, P.K.; Smyth, R.

    2005-01-01

    This paper reports estimates of the long- and short-run elasticities of residential demand for electricity in Australia using the bounds testing procedure to cointegration, within an autoregressive distributive lag framework. In the long run, we find that income and own price are the most important determinants of residential electricity demand, while temperature is significant some of the time and gas prices are insignificant. Our estimates of long-run income elasticity and price elasticity of demand are consistent with previous studies, although they are towards the lower end of existing estimates. As expected, the short-run elasticities are much smaller than the long-run elasticities, and the coefficients on the error-correction coefficients are small consistent with the fact that in the short-run energy appliances are fixed. (author)

  17. Modeling global residential sector energy demand for heating and air conditioning in the context of climate change

    International Nuclear Information System (INIS)

    Isaac, Morna; Vuuren, Detlef P. van

    2009-01-01

    In this article, we assess the potential development of energy use for future residential heating and air conditioning in the context of climate change. In a reference scenario, global energy demand for heating is projected to increase until 2030 and then stabilize. In contrast, energy demand for air conditioning is projected to increase rapidly over the whole 2000-2100 period, mostly driven by income growth. The associated CO 2 emissions for both heating and cooling increase from 0.8 Gt C in 2000 to 2.2 Gt C in 2100, i.e. about 12% of total CO 2 emissions from energy use (the strongest increase occurs in Asia). The net effect of climate change on global energy use and emissions is relatively small as decreases in heating are compensated for by increases in cooling. However, impacts on heating and cooling individually are considerable in this scenario, with heating energy demand decreased by 34% worldwide by 2100 as a result of climate change, and air-conditioning energy demand increased by 72%. At the regional scale considerable impacts can be seen, particularly in South Asia, where energy demand for residential air conditioning could increase by around 50% due to climate change, compared with the situation without climate change

  18. Index decomposition analysis of residential energy consumption in China: 2002–2010

    International Nuclear Information System (INIS)

    Nie, Hongguang; Kemp, René

    2014-01-01

    Highlights: • We examine residential energy use in China and predict household electricity use. • We decompose the dramatic increase of residential energy use in China. • Driving factors consist of population, floor space, energy mix and appliances. • Floor space per capita effect becomes increasingly important over time. • Electricity use from appliances will continue to rise despite a saturation. - Abstract: Residential energy consumption in China increased dramatically over the period of 2002–2010. In this paper, we undertake a decomposition analysis of changes in energy use by Chinese households for five energy-using activities: space heating/cooling, cooking, lighting and electric appliances. We investigate to what extent changes in energy use are due to changes from appliances and to change in floor space, population and energy mix. Our decomposition analysis is based on the logarithmic mean Divisia index technique using data from the China statistical yearbook and China energy statistical yearbook in the period of 2002–2010. According to our results, the increase in energy-using appliances is the biggest contributor to the increase of residential energy consumption during 2002–2010 but the effect declines over time, due to energy efficiency improvements in those appliances. The second most important contributor is floor space per capita, which increased with 28%. Of the four factors, population is the most stable factor and energy mix is the least important factor. We predicted electricity use, with the help of regression-based predictions for ownership of appliances and the energy efficiency of appliances. We found that electricity use will continue to rise despite a gradual saturation of demand

  19. The performance of a residential heat pump operating with a nonazeotropic binary refrigerant mixture

    Science.gov (United States)

    Didion, D.; Mulroy, W.

    Results of laboratory measurement of the performance change of a substantially unmodified residential heat pump designed for 222 when charged with a non azeotropic, binary mixture of R1381 and R152a is presented. Results are presented for various sizes of fixed expansion devices. The effect of gliding temperature in the saturation zone was found to be small. The effect of compositions shift by flash distillation in the accumulator was found to measurably improve low temperature heating performance. It was further observed that some system modification (such as the addition of a receiver) could have further enhanced this low temperature heating performance improvement.

  20. Potential Effect and Analysis of High Residential Solar Photovoltaic (PV Systems Penetration to an Electric Distribution Utility (DU

    Directory of Open Access Journals (Sweden)

    Jeffrey Tamba Dellosa

    2016-11-01

    Full Text Available The Renewable Energy Act of 2008 in the Philippines provided an impetus for residential owners to explore solar PV installations at their own rooftops through the Net-Metering policy. The Net-Metering implementation through the law however presented some concerns with inexperienced electric DU on the potential effect of high residential solar PV system installations. It was not known how a high degree of solar integration to the grid can possibly affect the operations of the electric DU in terms of energy load management. The primary objective of this study was to help the local electric DU in the analysis of the potential effect of high residential solar PV system penetration to the supply and demand load profile in an electric distribution utility (DU grid in the province of Agusan del Norte, Philippines. The energy consumption profiles in the year 2015 were obtained from the electric DU operating in the area. An average daily energy demand load profile was obtained from 0-hr to the 24th hour of the day based from the figures provided by the electric DU. The assessment part of the potential effect of high solar PV system integration assumed four potential total capacities from 10 Mega Watts (MW to 40 MW generated by all subscribers in the area under study at a 10 MW interval. The effect of these capacities were measured and analyzed with respect to the average daily load profile of the DU. Results of this study showed that a combined installations beyond 20 MWp coming from all subscribers is not viable for the local electric DU based on their current energy demand or load profile. Based from the results obtained, the electric DU can make better decisions in the management of high capacity penetration of solar PV systems in the future, including investment in storage systems when extra capacities are generated. Article History: Received July 15th 2016; Received in revised form Sept 23rd 2016; Accepted Oct 1st 2016; Available online How to Cite

  1. Ash reduction system using electrically heated particulate matter filter

    Science.gov (United States)

    Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J; He, Yongsheng [Sterling Heights, MI

    2011-08-16

    A control system for reducing ash comprises a temperature estimator module that estimates a temperature of an electrically heated particulate matter (PM) filter. A temperature and position estimator module estimates a position and temperature of an oxidation wave within the electrically heated PM filter. An ash reduction control module adjusts at least one of exhaust flow, fuel and oxygen levels in the electrically heated PM filter to adjust a position of the oxidation wave within the electrically heated PM filter based on the oxidation wave temperature and position.

  2. Modeling electric load and water consumption impacts from an integrated thermal energy and rainwater storage system for residential buildings in Texas

    International Nuclear Information System (INIS)

    Upshaw, Charles R.; Rhodes, Joshua D.; Webber, Michael E.

    2017-01-01

    Highlights: • Hydronic integrated rainwater thermal storage (ITHERST) system concept presented. • ITHERST system modeled to assess peak electric load shifting and water savings. • Case study shows 75% peak load reduction and 9% increase in energy consumption. • Potable rainwater collection could provide ∼50–90% of water used for case study. - Abstract: The United States’ built environment is a significant direct and indirect consumer of energy and water. In Texas, and other parts of the Southern and Western US, air conditioning loads, particularly from residential buildings, contribute significantly to the peak electricity load on the grid, straining transmission. In parallel, water resources in these regions are strained by growing populations and shrinking supplies. One potential method to address both of these issues is to develop integrated thermal energy and auxiliary water (e.g. rainwater, greywater, etc.) storage and management systems that reduce peak load and freshwater consumption. This analysis focuses on a proposed integrated thermal energy and rainwater storage (ITHERST) system that is incorporated into a residential air-source chiller/heat pump with hydronic distribution. This paper describes a step-wise hourly thermodynamic model of the thermal storage system to assess on-peak performance, and a daily volume-balance model of auxiliary water collection and consumption to assess water savings potential. While the model is generalized, this analysis uses a case study of a single family home in Austin, Texas to illustrate its capabilities. The results indicate this ITHERST system could reduce on-peak air conditioning electric power demand by over 75%, with increased overall electric energy consumption of approximately 7–9%, when optimally sized. Additionally, the modeled rainwater collection reduced municipal water consumption by approximately 53–89%, depending on the system size.

  3. Sensitivity of district heating system operation to heat demand reductions and electricity price variations: A Swedish example

    International Nuclear Information System (INIS)

    Åberg, M.; Widén, J.; Henning, D.

    2012-01-01

    In the future, district heating companies in Sweden must adapt to energy efficiency measures in buildings and variable fuel and electricity prices. Swedish district heating demands are expected to decrease by 1–2% per year and electricity price variations seem to be more unpredictable in the future. A cost-optimisation model of a Swedish local district heating system is constructed using the optimisation modelling tool MODEST. A scenario for heat demand changes due to increased energy efficiency in buildings, combined with the addition of new buildings, is studied along with a sensitivity analysis for electricity price variations. Despite fears that heat demand reductions will decrease co-generation of clean electricity and cause increased global emissions, the results show that anticipated heat demand changes do not increase the studied system's primary energy use or global CO 2 emissions. The results further indicate that the heat production plants and the fuels used within the system have crucial importance for the environmental impact of district heat use. Results also show that low seasonal variations in electricity price levels with relatively low winter prices promote the use of electric heat pumps. High winter prices on the other hand promote co-generation of heat and electricity in CHP plants. -- Highlights: ► A MODEST optimisation model of the Uppsala district heating system is built. ► The impact of heat demand change on heat and electricity production is examined. ► An electricity price level sensitivity analysis for district heating is performed. ► Heat demand changes do not increase the primary energy use or global CO 2 emissions. ► Low winter prices promote use of electric heat pumps for district heating production.

  4. Residential heating costs: A comparison of geothermal solar and conventional resources

    Science.gov (United States)

    Bloomster, C. H.; Garrett-Price, B. A.; Fassbender, L. L.

    1980-08-01

    The costs of residential heating throughout the United States using conventional, solar, and geothermal energy were determined under current and projected conditions. These costs are very sensitive to location, being dependent on the local prices of conventional energy supplies, local solar insolation, climate, and the proximity and temperature of potential geothermal resources. The sharp price increases in imported fuels during 1979 and the planned decontrol of domestic oil and natural gas prices have set the stage for geothermal and solar market penetration in the 1980's.

  5. Feasibility study on combined use of residential SOFC cogeneration system and plug-in hybrid electric vehicle from energy-saving viewpoint

    International Nuclear Information System (INIS)

    Wakui, Tetsuya; Wada, Naohiro; Yokoyama, Ryohei

    2012-01-01

    Highlights: ► Optimal operational planning for combined use of SOFC-CGS and PHEV is conducted. ► Charging PHEV with SOFC-CGS increases electric capacity factor of SOFC-CGS. ► Energy-saving effect of combined use is higher than that of their separate use. ► Combined use provides energy savings in both residential and transport sectors. - Abstract: The energy-saving effect of a combined use of a residential solid oxide fuel cell cogeneration system (SOFC-CGS) that adopts a continuous operation, and a plug-in hybrid electric vehicle (PHEV) is discussed by optimal operational planning based on mixed-integer linear programming. This combined use aims to increase the electric capacity factor of the SOFC-CGS by charging the PHEV using the SOFC-CGS electric power output late at night, and targets the application in regions where the reverse power flow from residential cogeneration systems to commercial electric power systems is not permitted, like in Japan. The optimal operation patterns of the combined use of 0.7-kWe SOFC-CGS and PHEV for a simulated energy demand with a sampling time of 1 h and various daily running distances of the PHEV show that this combined use increases the electric capacity factor of the SOFC-CGS and saves more energy in comparison with their separate use in which the SOFC-CGS is used but the PHEV is charged only with purchased electric power. Furthermore, it is found that at the PHEV daily running distance of 12 km/d, the reduction rate of the annual primary energy consumption for this combined use increases by up to 3.7 percentage points relative to their separate use. Consequently, this feasibility study reveals that the combined use of the SOFC-CGS and PHEV provides the synergistic effect on energy savings in the residential and transport sectors. For the practical use, simulation scenarios considering the energy demand fluctuations with short periods and real-time pricing of the purchased electric power must be considered as future

  6. Heat pumps; Synergy of high efficiency and low carbon electricity

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Akio

    2010-09-15

    Heat pump is attracting wide attention for its high efficiency to utilize inexhaustible and renewable ambient heat in the environment. With its rapid innovation and efficiency improvement, this technology has a huge potential to reduce CO2 emissions by replacing currently widespread fossil fuel combustion systems to meet various heat demands from the residential, commercial and industrial sectors. Barriers to deployment such as low public awareness and a relatively long pay-back period do exist, so it is strongly recommended that each country implement policies to promote heat pumps as a renewable energy option and an effective method to combat global warming.

  7. Heat pumps: Residential and commercial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The bibliography contains citations concerning the design and development of heat pumps for use in residential houses, apartments, and commercial installations. Energy exchange systems examined include air-to-air, ground-coupled, air-to-water, and water-to-water types. The citations cover costs and reliability of the heat pump systems, and studies of operations in differing climates and seasons. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  8. An optimisation framework for thermal energy storage integration in a residential heat pump heating system

    International Nuclear Information System (INIS)

    Renaldi, R.; Kiprakis, A.; Friedrich, D.

    2017-01-01

    Highlights: • An integrated framework for the optimal design of low carbon heating systems. • Development of a synthetic heat demand model with occupancy profiles. • Linear model of a heat pump with thermal energy storage heating system. • Evaluation of domestic heating system from generally available input parameters. • The lower carbon heating system can be cost competitive with conventional systems. - Abstract: Domestic heating has a large share in the UK total energy consumption and significant contribution to the greenhouse gas emissions since it is mainly fulfilled by fossil fuels. Therefore, decarbonising the heating system is essential and an option to achieve this is by heating system electrification through heat pumps (HP) installation in combination with renewable power generation. A potential increase in performance and flexibility can be achieved by pairing HP with thermal energy storage (TES), which allows the shifting of heat demand to off peak periods or periods with surplus renewable electricity. We present a design and operational optimisation model which is able to assess the performance of HP–TES relative to conventional heating systems. The optimisation is performed on a synthetic heat demand model which requires only the annual heat demand, temperature and occupancy profiles. The results show that the equipment and operational cost of a HP system without TES are significantly higher than for a conventional system. However, the integration of TES and time-of-use tariffs reduce the operational cost of the HP systems and in combination with the Renewable Heating Incentive make the HP systems cost competitive with conventional systems. The presented demand model and optimisation procedure will enable the design of low carbon district heating systems which integrate the heating system with the variable renewable electricity supply.

  9. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  10. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  11. Analysis and proposal of implementation effects of heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period

    International Nuclear Information System (INIS)

    Bao Lingling; Zhao Jing; Zhu Neng

    2012-01-01

    In China, northern heating region contains approximately 6.5 billion m 2 residential building areas accounting for 15% of the total residential living areas of urban and rural. About 70% of the urban residential buildings in north China are high energy consumption buildings. The task of heat metering and energy efficiency retrofit of 0.15 billion m 2 existing residential buildings in northern heating areas of China in “the 11th Five-Year Plan” period was proposed by the Ministry of Housing and Urban–Rural Development (MOHURD) in 2007 and completed in 2010. This paper introduced both central and local governments' efforts on organization, implementation and finance, etc. Then several retrofitting effects involving improving the people's livelihood, mobilizing the enthusiasm of residents for the retrofit and driving the development of relevant industries were presented. Finally, on the basis of analyzing the issues encountered in the progress of the retrofit in the past 4 years, the paper gave some policy proposals on organization system, financing models, reward mechanism, and heating system reformation to help to promote the energy efficiency retrofit in “the 12th Five-Year Plan” period. - Highlights: ► Specific approaches of heat metering and energy efficiency retrofit (HMEER) at central and local level are introduced. ► Main HMEER effects are presented. ► Analyzing several issues encountered in the progress of the HMEER. ► Corresponding proposals are provided.

  12. The Risk of Residential Peak Electricity Demand: A Comparison of Five European Countries

    Directory of Open Access Journals (Sweden)

    Jacopo Torriti

    2017-03-01

    Full Text Available The creation of a Europe-wide electricity market combined with the increased intermittency of supply from renewable sources calls for an investigation into the risk of aggregate peak demand. This paper makes use of a risk model to assess differences in time-use data from residential end-users in five different European electricity markets. Drawing on the Multinational Time-Use Survey database, it assesses risk in relation to the probability of electrical appliance use within households for five European countries. Findings highlight in which countries and for which activities the risk of aggregate peak demand is higher and link smart home solutions (automated load control, dynamic pricing and smart appliances to different levels of peak demand risk.

  13. Life cycle study. Carbon dioxide emissions lower in electric heating than in oil heating

    Energy Technology Data Exchange (ETDEWEB)

    Heikkinen, A.; Jaervinen, P.; Nikula, A.

    1996-11-01

    A primary objective of energy conservation is to cut carbon dioxide emissions. A comparative study on the various heating forms, based on the life cycle approach, showed that the carbon dioxide emissions resulting form heating are appreciably lower now that electric heating has become more common. The level of carbon dioxide emissions in Finland would have been millions of tonnes higher had oil heating been chosen instead of electric heating. (orig.)

  14. Factor Analysis of Residential Energy Consumption at the Provincial Level in China

    Directory of Open Access Journals (Sweden)

    Weibin Lin

    2014-11-01

    Full Text Available This paper analyzes the differences in the amount and the structure of residential energy consumption at the provincial level in China and identifies the hidden factors behind such differences. The econometrical analysis reveals that population, economic development level, energy resource endowment and climatic conditions are the main factors driving residential energy consumption; while the regional differences in energy consumption per capita and the consumption structure can be mainly illustrated by various economic development levels, energy resource endowments and climatic conditions. Economic development level has a significant positive impact on the proportion of gasoline consumption, whereas its impact on the proportion of electricity consumption is not notable; energy resource endowment and climatic condition indirectly affect both the proportion of electricity consumption and that of gasoline consumption, primarily through their impacts on the proportions of coal consumption and heat consumption.

  15. Field evaluation and assessment of thermal energy storage for residential space heating

    Science.gov (United States)

    Hersh, H. N.

    1982-02-01

    A data base was developed based on two heating seasons and 45 test and 30 control homes in Maine and Vermont. Based on first analysis of monitored temperatures and electrical energy used for space heating, fuel bills and reports of users and utilities, the technical performance of TES ceramic and hydronic systems is deemed to be technically satisfactory and there is a high degree of customer acceptance and positive attitudes towards TES. Analysis of house data shows a high degree of variability in electric heat energy demand for a given degree-day. An analysis is underway to investigate relative differences in the efficiency of electricity utilization of storage and direct heating devices. The much higher price of storge systems relative to direct systems is an impediment to market penetration. A changing picture of rate structures may encourage direct systems at the expense of storage systems.

  16. Economic Model Predictive Control for Hot Water Based Heating Systems in Smart Buildings

    DEFF Research Database (Denmark)

    Awadelrahman, M. A. Ahmed; Zong, Yi; Li, Hongwei

    2017-01-01

    This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank...... as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load...

  17. Heating and cooling energy demand and related emissions of the German residential building stock under climate change

    International Nuclear Information System (INIS)

    Olonscheck, Mady; Holsten, Anne; Kropp, Juergen P.

    2011-01-01

    The housing sector is a major consumer of energy. Studies on the future energy demand under climate change which also take into account future changes of the building stock, renovation measures and heating systems are still lacking. We provide the first analysis of the combined effect of these four influencing factors on the future energy demand for room conditioning of residential buildings and resulting greenhouse gas (GHG) emissions in Germany until 2060. We show that the heating energy demand will decrease substantially in the future. This shift will mainly depend on the number of renovated buildings and climate change scenarios and only slightly on demographic changes. The future cooling energy demand will remain low in the future unless the amount of air conditioners strongly increases. As a strong change in the German energy mix is not expected, the future GHG emissions caused by heating will mainly depend on the energy demand for future heating. - Highlights: → The future heating energy demand of German residential buildings strongly decreases. → Extent of these changes mainly depends on the number of renovated buildings. → Demographic changes will only play a minor role. → Cooling energy demand will remain low in future but with large insecurities. → Germany's 2050 emission targets for the building stock are ambitious.

  18. Substituting natural gas heating for electric heating: assessment of the energy and environmental effects in Ontario

    International Nuclear Information System (INIS)

    Rosen, M.A.; Sy, E.; Gharghouri, P.

    1996-01-01

    A study was conducted to find practical ways to reduce Ontario's energy consumption and environmental emissions. A major portion of the study focused on the advantages of cogeneration in certain regions and sectors of Ontario. Substituting direct fuel heating with natural gas for electric heating was the principal recommendation. Results of a technical analysis of the effects of substituting electric heating with natural gas heating were described. One of the benefits of this substitution would be reduced fuel energy requirements for direct heating, relative to the two-step process of electricity generation followed by electric heating. It was suggested that natural gas should still be used for electricity generation because natural gas has many advantages as an electricity supply option including reductions in coal and uranium use and related emissions. It was recommended that developers and designers of energy systems seriously consider this option. 33 refs., 2 tabs., 4 figs

  19. Comparative analysis of efficiency in cooking with natural gas and electricity

    International Nuclear Information System (INIS)

    Amell Arrieta, Andres; Cadavid Sierra Francisco Javier; Ospina Ospina, Juan Carlos

    2001-01-01

    The natural gas will have, at the Aburra Valley, a massive application in residential process like heating water and cooking, historically doing with electricity. In the study of electricity substitution in necessary to estimate the gas consumption in order to keep satisfying the energetic requirements at the different strata supposing that, alimentary habits in these have not important valuation through the time. Since the volume of natural gas requirements for the electricity substitution at given conditions depend on electrical energy before substitution, electrical equipment efficiency, gas equipment efficiency and gas substitution heating value, the determination of these efficiencies are necessary. This work presents the calculation processes comparing gas heating and cooking processes, versus electrical devises taking in mind several schemes and essay conditions

  20. Proceedings: Meeting customer needs with heat pumps, 1991

    International Nuclear Information System (INIS)

    1992-12-01

    Electric heat pumps provide a growing number of residential and commercial customers with space heating and cooling as well as humidity control and water heating. Industrial customers use heat pump technology for energy-efficient, economical process heating and cooling. Heat pumps help utilities meet environmental protection needs and satisfy their load-shape objectives. The 1991 conference was held in Dallas on October 15--18, featuring 60 speakers representing electric utilities, consulting organizations, sponsoring organizations, and heat pump manufacturers. The speakers presented the latest information about heat pump markets, technologies, applications, trade ally programs, and relevant issues. Participants engaged in detailed discussions in ''breakout'' and parallel sessions and viewed more than 30 exhibits of heat pumps, software, and other products and services supporting heat pump installations and service. Electric utilities have the greatest vested interest in the sale of electric heat pumps and thus have responsibility to ensure quality installations through well-trained technicians, authoritative and accurate technical information, and wellinformed design professionals. The electric heat pump is an excellent tool for the electric utility industry's response to environmental and efficiency challenges as well as to competition from other fuel sources. Manufacturers are continually introducing new products and making research results available to meet these challenges. Industrial process heat pumps offer customers the ability to supply heat to process at a lower cost than heat supplied by primary-fuel-fired boilers. From the utility perspective these heat pumps offer an opportunity for a new electric year-round application

  1. Life Cycle Assessment of Residential Heating and Cooling Systems in Minnesota A comprehensive analysis on life cycle greenhouse gas (GHG) emissions and cost-effectiveness of ground source heat pump (GSHP) systems compared to the conventional gas furnace and air conditioner system

    Science.gov (United States)

    Li, Mo

    Ground Source Heat Pump (GSHP) technologies for residential heating and cooling are often suggested as an effective means to curb energy consumption, reduce greenhouse gas (GHG) emissions and lower homeowners' heating and cooling costs. As such, numerous federal, state and utility-based incentives, most often in the forms of financial incentives, installation rebates, and loan programs, have been made available for these technologies. While GSHP technology for space heating and cooling is well understood, with widespread implementation across the U.S., research specific to the environmental and economic performance of these systems in cold climates, such as Minnesota, is limited. In this study, a comparative environmental life cycle assessment (LCA) is conducted of typical residential HVAC (Heating, Ventilation, and Air Conditioning) systems in Minnesota to investigate greenhouse gas (GHG) emissions for delivering 20 years of residential heating and cooling—maintaining indoor temperatures of 68°F (20°C) and 75°F (24°C) in Minnesota-specific heating and cooling seasons, respectively. Eight residential GSHP design scenarios (i.e. horizontal loop field, vertical loop field, high coefficient of performance, low coefficient of performance, hybrid natural gas heat back-up) and one conventional natural gas furnace and air conditioner system are assessed for GHG and life cycle economic costs. Life cycle GHG emissions were found to range between 1.09 × 105 kg CO2 eq. and 1.86 × 10 5 kg CO2 eq. Six of the eight GSHP technology scenarios had fewer carbon impacts than the conventional system. Only in cases of horizontal low-efficiency GSHP and hybrid, do results suggest increased GHGs. Life cycle costs and present value analyses suggest GSHP technologies can be cost competitive over their 20-year life, but that policy incentives may be required to reduce the high up-front capital costs of GSHPs and relatively long payback periods of more than 20 years. In addition

  2. Techno-economic assessment and optimization of stirling engine micro-cogeneration systems in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Alanne, Kari; Soederholm, Niklas; Siren, Kai [Dept. of Energy Technology, Helsinki University of Technology, P.O. Box 4100, 02015 TKK (Finland); Beausoleil-Morrison, Ian [Dept. of Mechanical and Aerospace Engineering, Carleton University, Ottawa (Canada)

    2010-12-15

    Micro-cogeneration offers numerous potential advantages for the supply of energy to residential buildings in the sense of improved energy efficiency and reduced environmental burdens. To realize these benefits, however, such systems must reduce energy costs, primary energy consumption, and CO{sub 2} emissions relative to conventional heating systems. In this paper, we search for optimized strategies for the integration of a Stirling engine-based micro-cogeneration system in residential buildings by comparing the performance of various system configurations and operational strategies with that of a reference system, i.e. hydronic heating and a low temperature gas boiler in standard and passive house constructions located in different climates. The IDA-ICE whole-building simulation program is employed with the Stirling engine micro-cogeneration model that was developed by IEA/ECBCS Annex 42. In this way the dynamic effects of micro-cogeneration devices, such as warm-ups and shutdowns, are accounted for. This study contributes to the research by addressing hourly changes in the fuel mix used for central electricity generation and the utilization of thermal exhaust through heat recovery. Our results suggest that an optimally operated micro-cogeneration system encompassing heat recovery and appropriate thermal storage would result in a 3-5% decrease in primary energy consumption and CO{sub 2} emissions when compared to a conventional hydronic heating system. Moreover, this configuration is capable of delivering annual savings in all the combinations of electricity and fuel price between 0.05 and 0.15 EUR kW h{sup -1}. As can be expected, these results are sensitive to the electrical energy supply mix, building type, and climate. (author)

  3. Techno-economic assessment and optimization of Stirling engine micro-cogeneration systems in residential buildings

    International Nuclear Information System (INIS)

    Alanne, Kari; Soederholm, Niklas; Siren, Kai; Beausoleil-Morrison, Ian

    2010-01-01

    Micro-cogeneration offers numerous potential advantages for the supply of energy to residential buildings in the sense of improved energy efficiency and reduced environmental burdens. To realize these benefits, however, such systems must reduce energy costs, primary energy consumption, and CO 2 emissions relative to conventional heating systems. In this paper, we search for optimized strategies for the integration of a Stirling engine-based micro-cogeneration system in residential buildings by comparing the performance of various system configurations and operational strategies with that of a reference system, i.e. hydronic heating and a low temperature gas boiler in standard and passive house constructions located in different climates. The IDA-ICE whole-building simulation program is employed with the Stirling engine micro-cogeneration model that was developed by IEA/ECBCS Annex 42. In this way the dynamic effects of micro-cogeneration devices, such as warm-ups and shutdowns, are accounted for. This study contributes to the research by addressing hourly changes in the fuel mix used for central electricity generation and the utilization of thermal exhaust through heat recovery. Our results suggest that an optimally operated micro-cogeneration system encompassing heat recovery and appropriate thermal storage would result in a 3-5% decrease in primary energy consumption and CO 2 emissions when compared to a conventional hydronic heating system. Moreover, this configuration is capable of delivering annual savings in all the combinations of electricity and fuel price between 0.05 and 0.15 Euro kW h -1 . As can be expected, these results are sensitive to the electrical energy supply mix, building type, and climate.

  4. Mathematical modeling of the energy consumption of heated swimming pools

    Energy Technology Data Exchange (ETDEWEB)

    Le Bel, C.; Millette, J. [LTE Shawinigan, Shawinigan, PQ (Canada)

    2007-07-01

    A mathematical model was developed to estimate the water temperature of a residential swimming pool. The model can compare 2 different situations and, if local climatic conditions are known, it can accurately predict energy costs of the pool relative to the total energy consumption of the house. When used with the appropriate energy transfer coefficient and weather file, the model can estimate the water temperature of a residential swimming pool having specific characteristics, such as in-ground, above-ground, heated or non-heated. The model is suitable for determining residential loads. It can be applied to different pool types and sizes, for different water heating scenarios and different climatic regions. Data obtained from the monitoring of water temperature and electricity use of 57 residential swimming pools was used to validate the model. In addition, 5 above-ground pools were installed on the property of LTE Shawinigan to allow for a more detailed study of the parameters involved in the thermal balance of a pool. The mathematical model, based on a global heat transfer coefficient, can determine the effect of a solar blanket and the effect of water volume. 14 refs., 5 tabs., 11 figs.

  5. High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Murphy, Richard W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

  6. Evaluation of advanced technologies for residential appliances and residential and commercial lighting

    Energy Technology Data Exchange (ETDEWEB)

    Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

    1995-01-01

    Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

  7. Residential on site solar heating systems: a project evaluation using the capital asset pricing model

    Energy Technology Data Exchange (ETDEWEB)

    Schutz, S.R.

    1978-12-01

    An energy source ready for immediate use on a commercial scale is solar energy in the form of On Site Solar Heating (OSSH) systems. These systems collect solar energy with rooftop panels, store excess energy in water storage tanks and can, in certain circumstances, provide 100% of the space heating and hot water required by the occupants of the residential or commercial structure on which the system is located. Such systems would take advantage of a free and inexhaustible energy source--sunlight. The principal drawback of such systems is the high initial capital cost. The solution would normally be a carefully worked out corporate financing plan. However, at the moment it is individual homeowners and not corporations who are attempting to finance these systems. As a result, the terms of finance are excessively stringent and constitute the main obstacle to the large scale market penetration of OSSH. This study analyzes the feasibility of OSSH as a private utility investment. Such systems would be installed and owned by private utilities and would displace other investment projects, principally electric generating plants. The return on OSSH is calculated on the basis of the cost to the consumer of the equivalent amount of electrical energy that is displaced by the OSSH system. The hurdle rate for investment in OSSH is calculated using the Sharpe--Lintner Capital Asset Pricing Model. The results of this study indicate that OSSH is a low risk investment having an appropriate hurdle rate of 7.9%. At this rate, OSSH investment appears marginally acceptable in northern California and unambiguously acceptable in southern California. The results also suggest that utility investment in OSSH should lead to a higher degree of financial leverage for utility companies without a concurrent deterioration in the risk class of utility equity.

  8. Economic analysis of using excess renewable electricity to displace heating fuels

    DEFF Research Database (Denmark)

    Pensini, Alessandro; Rasmussen, Claus Nygaard; Kempton, Willett

    2014-01-01

    . Because excess electricity appears to be cost-optimum, this raises the question as to whether the excess electricity, which in the case of wind power is predominately produced in colder weather, might displace other fuels for purposes such as heat. This study models using excess electricity for heating......, based on an analysis of electricity and heat use in a TSO in the North-Eastern part of the United States (PJM Interconnection). The heating system was modeled as heat pump based district heating (HPDH) with thermal energy storage (TES). Thus, excess electricity is transformed into heat, which is easy....... An algorithm that calculates the total cost of a unit of heat was used to determine the economically optimal size of the system’s main components and the influence that natural gas (NG) and electricity prices have on this optimum. It was found that a system based on heat pumps (HP) and centralized thermal...

  9. Electric heating provides a high level of home comfort - economically

    Energy Technology Data Exchange (ETDEWEB)

    Haapakoski, M.

    1997-11-01

    Research and development at IVO in the area of electric heating boasts a tradition going back almost thirty years. Research aimed at further progress is continuing. IVO and power companies launched the `Electrically heated houses of the century` project four years ago. The first results show that electric heating continues to be very competitive with other heating systems. It is an economical way of heating the home and it also increases the comfort of those living there

  10. C-Vine copula mixture model for clustering of residential electrical load pattern data

    OpenAIRE

    Sun, M; Konstantelos, I; Strbac, G

    2016-01-01

    The ongoing deployment of residential smart meters in numerous jurisdictions has led to an influx of electricity consumption data. This information presents a valuable opportunity to suppliers for better understanding their customer base and designing more effective tariff structures. In the past, various clustering methods have been proposed for meaningful customer partitioning. This paper presents a novel finite mixture modeling framework based on C-vine copulas (CVMM) for carrying out cons...

  11. Natural gas–biomass dual fuelled microturbines: Comparison of operating strategies in the Italian residential sector

    International Nuclear Information System (INIS)

    Pantaleo, Antonio M.; Camporeale, Sergio; Shah, Nilay

    2014-01-01

    This paper compares different operating strategies for small scale (100 kWe) combined heat and power (CHP) plants fired by natural gas and solid biomass to serve a residential energy demand. The focus is on a dual fuel micro gas turbine (MGT) cycle. Various biomass/natural gas energy input ratios are modelled, in order to assess the trade-offs between: (i) lower energy conversion efficiency and higher investment cost when increasing the biomass input rate; (ii) higher primary energy savings and revenues from feed-in tariff available for biomass electricity fed into the grid. The strategies of baseload (BL), heat driven (HD) and electricity driven (ED) plant operation are compared, for an aggregate of residential end-users in cold, average and mild climate conditions. On the basis of the results from thermodynamic assessment and simulation at partial load operation, CAPEX and OPEX estimates, and Italian energy policy scenario (incentives available for biomass electricity, on-site and high efficiency CHP), the maximum global energy efficiency, primary energy savings and investment profitability is found, as a function of biomass/natural gas ratio, plant operating strategy and energy demand typology. The thermal and electric conversion efficiency ranged respectively between 46 and 38% and 30 and 19% for the natural gas and biomass fired case studies. The IRR of the investment was highly influenced by the load/CHP thermal power ratio and by the operation mode. The availability of high heat demand levels was also a key factor, to avoid wasted cogenerated heat and maximize CHP sales revenues. BL operation presented the highest profitability because of the higher revenues from electricity sales. Climate area was another important factor, mainly in case of low load/CHP ratios. Moreover, at low load/CHP power ratio and for the BL operation mode, the dual fuel option presented the highest profitability. This is due to the lower cost of biomass fuel in comparison to natural

  12. Energy saving or privatization? The case of the electric residential sector of Mexico; Ahorro de energia o privatizacion? El caso del sector electrico residencial de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Friedmann, Rafael [University of California, Berkeley, CA (United States)

    1994-12-31

    The validity of the premise that proposes the privatization of the electric sector as a solution to the problem of obtaining enough investment capital for the continuous expansion of the electric sector is examined. It is shown that the growth of the demand foreseen for the residential sector for year 2000, can be totally reduced by introducing technologies economically feasible to increase the efficiency and end uses of the residential electricity. With the efficient use of the electricity, the economical development is allowed for the residential sector, without large increments of the residential electricity demand. [Espanol] Se examina la validez de la premisa que propone la privatizacion del sector electrico como una solucion al problema de conseguir suficientes capitales de inversion para la continua expansion del sector. Se muestra que se puede reducir casi totalmente el crecimiento en la demanda prevista del sector residencial al ano 2000, introduciendo tecnologias economicamente factibles para aumentar la eficiencia en los usos finales de electricidad residencial. Con el uso eficiente de la electricidad, se permite el desarrollo economico del sector residencial sin grandes incrementos en la demanda residencial de electricidad.

  13. Energy saving or privatization? The case of the electric residential sector of Mexico; Ahorro de energia o privatizacion? El caso del sector electrico residencial de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Friedmann, Rafael [University of California, Berkeley, CA (United States)

    1993-12-31

    The validity of the premise that proposes the privatization of the electric sector as a solution to the problem of obtaining enough investment capital for the continuous expansion of the electric sector is examined. It is shown that the growth of the demand foreseen for the residential sector for year 2000, can be totally reduced by introducing technologies economically feasible to increase the efficiency and end uses of the residential electricity. With the efficient use of the electricity, the economical development is allowed for the residential sector, without large increments of the residential electricity demand. [Espanol] Se examina la validez de la premisa que propone la privatizacion del sector electrico como una solucion al problema de conseguir suficientes capitales de inversion para la continua expansion del sector. Se muestra que se puede reducir casi totalmente el crecimiento en la demanda prevista del sector residencial al ano 2000, introduciendo tecnologias economicamente factibles para aumentar la eficiencia en los usos finales de electricidad residencial. Con el uso eficiente de la electricidad, se permite el desarrollo economico del sector residencial sin grandes incrementos en la demanda residencial de electricidad.

  14. Change in consumer sensitivity to electricity prices in response to retail deregulation: A panel empirical analysis of the residential demand for electricity in the United States

    International Nuclear Information System (INIS)

    Nakajima, Tadahiro; Hamori, Shigeyuki

    2010-01-01

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections-all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states-and two time series-the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods-before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states.

  15. Change in consumer sensitivity to electricity prices in response to retail deregulation. A panel empirical analysis of the residential demand for electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Tadahiro [The Kansai Electric Power Company, Incorporated, 6-16, Nakanoshima 3-chome, Kita-Ku, Osaka 530-8270 (Japan); Hamori, Shigeyuki [Faculty of Economics, Kobe University 2-1, Rokkodai, Nada-Ku, Kobe 657-8501 (Japan)

    2010-05-15

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections - all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states - and two time series - the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods - before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states. (author)

  16. An energy and cost analysis of residential heat pumps in northern climates

    Science.gov (United States)

    Martin, J. K.; Oneal, D. L.

    1980-04-01

    Lack of natural gas and high oil prices, combined with the large energy costs of electric resistance heat have forced renewed attention to the heat pump in colder climates. The diversity in heating energy use and cost effectiveness of forty-one currently retailed heat pumps in three northern cities, Boston, Denver, and Minneapolis, were examined. Heat pump heating energy use and annualized life cycle costs were compared with other forms of space heating equipment in those same cities.

  17. Residential proximity to major roads and term low birth weight: the roles of air pollution, heat, noise, and road-adjacent trees.

    Science.gov (United States)

    Dadvand, Payam; Ostro, Bart; Figueras, Francesc; Foraster, Maria; Basagaña, Xavier; Valentín, Antònia; Martinez, David; Beelen, Rob; Cirach, Marta; Hoek, Gerard; Jerrett, Michael; Brunekreef, Bert; Nieuwenhuijsen, Mark J

    2014-07-01

    Maternal residential proximity to roads has been associated with adverse pregnancy outcomes. However, there is no study investigating mediators or buffering effects of road-adjacent trees on this association. We investigated the association between mothers' residential proximity to major roads and term low birth weight (LBW), while exploring possible mediating roles of air pollution (PM(2.5), PM(2.5-10), PM(10), PM(2.5) absorbance, nitrogen dioxide, and nitrogen oxides), heat, and noise and buffering effect of road-adjacent trees on this association. This cohort study was based on 6438 singleton term births in Barcelona, Spain (2001-2005). Road proximity was measured as both continuous distance to and living within 200 m from a major road. We assessed individual exposures to air pollution, noise, and heat using, respectively, temporally adjusted land-use regression models, annual averages of 24-hour noise levels across 50 m and 250 m, and average of satellite-derived land-surface temperature in a 50-m buffer around each residential address. We used vegetation continuous fields to abstract tree coverage in a 200-m buffer around major roads. Living within 200 m of major roads was associated with a 46% increase in term LBW risk; an interquartile range increase in heat exposure with an 18% increase; and third-trimester exposure to PM(2.5), PM(2.5-10), and PM10 with 24%, 25%, and 26% increases, respectively. Air pollution and heat exposures together explained about one-third of the association between residential proximity to major roads and term LBW. Our observations on the buffering of this association by road-adjacent trees were not consistent between our 2 measures of proximity to major roads. An increased risk of term LBW associated with proximity to major roads was partly mediated by air pollution and heat exposures.

  18. Household electricity and gas consumption for heating homes

    International Nuclear Information System (INIS)

    Jeong, Jaehoon; Seob Kim, Chang; Lee, Jongsu

    2011-01-01

    Energy consumption has been drastically changed because of energy source depletion, price fluctuations, development and penetration of alternative energy sources, and government policies. Household energy sources are interrelated, and energy price and household characteristics, such as income level and dwelling size, affect the usage. To supply energy consistently and achieve a balance between production and consumption, stakeholders must understand consumer energy-consumption behavior. Therefore, this study identifies household heating energy usage patterns and the substitutive and/or complementary relationships between electricity and gas. Based on a multiple discrete-continuous extreme value model, household utility structure is identified from data on gas-heating usage. Results show greater utility and the smallest satiation values for gas boilers than for electric heaters and electric heating beds. The effects of consumer socioeconomic and environmental characteristics on the choice of heating energy sources were analyzed. Also, for further comparison, the respondents were split into high and low categories for income, heating degree days, dwelling size, and gas usage. Gas was found to be the most economical heating choice for households. - Research highlights: → This study investigates household electricity and gas consumption behavior for heating. → It also studied the relationship between two energy sources. → A research framework is suggested by combining the CDA and the MDCEV models. → It provides quantitative data that might be used for designing efficient energy policies.

  19. Integrated Management of Residential Energy Resources

    Directory of Open Access Journals (Sweden)

    Antunes C. H.

    2012-10-01

    Full Text Available The increasing deployment of distributed generation systems based on renewables in the residential sector, the development of information and communication technologies and the expected evolution of traditional power systems towards smart grids are inducing changes in the passive role of end-users, namely with stimuli to change residential demand patterns. The residential user should be able to make decisions and efficiently manage his energy resources by taking advantages from his flexibility in load usage with the aim to minimize the electricity bill without depreciating the quality of energy services provided. The aim of this paper is characterizing electricity consumption in the residential sector and categorizing the different loads according to their typical usage, working cycles, technical constraints and possible degree of control. This categorization of end-use loads contributes to ascertain the availability of controllable loads to be managed as well as the different direct management actions that can be implemented. The ability to implement different management actions over diverse end-use load will increase the responsiveness of demand and potentially raises the willingness of end-users to accept such activities. The impacts on the aggregated national demand of large-scale dissemination of management systems that would help the end-user to make decisions regarding electricity consumption are predicted using a simulator that generates the aggregated residential sector electricity consumption under variable prices.

  20. 46 CFR 169.685 - Electric heating and cooking equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Electric heating and cooking equipment. 169.685 Section... More on Vessels of Less Than 100 Gross Tons § 169.685 Electric heating and cooking equipment. (a) Each...) All electric cooking equipment, attachments, and devices, must be of rugged construction and so...

  1. The electric tariff in the residential sector; Tarificacion electrica en el sector residencial

    Energy Technology Data Exchange (ETDEWEB)

    Sheinbaum Pardo, Claudia [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1997-12-31

    The main objective of this paper is to make an historical revision and analyze the current condition of the electric tariffs in the Mexican residential sector and ask ourselves if the equalization of tariffs generates the possibility that the entire population has access to the electricity service. The document is divided into three parts. The first one presents the history and the tendencies of the tariffs in the domestic sector in Mexico since 1973 until 1996 and the current tariff structure. The second one describes the characteristics of the residential users and mention is made of how the increment of the electric tariffs would affect the various population sectors. The last part of this paper presents some tariff criteria, that take into account energy conservation measures [Espanol] El objetivo principal de este trabajo es hacer una revision historica y analizar la situacion actual de las tarifas electricas en el sector residencial mexicano y preguntarnos si la igualdad de tarifas genera la posibilidad de que toda la poblacion tenga acceso al servicio electrico. El documento se divide en tres partes. La primera presenta la historia y tendencias de las tarifas del sector domestico en Mexico desde 1973 hasta 1996 y la estructura tarifaria actual. La segunda describe las caracteristicas de los usuarios residenciales y se menciona como afectaria el incremento de las tarifas electricas a los distintos sectores de la poblacion. La ultima parte de este trabajo presenta algunos criterios de tarificacion, que toman en cuenta medidas de ahorro de energia

  2. Modelling weather effects for impact analysis of residential time-of-use electricity pricing

    International Nuclear Information System (INIS)

    Miller, Reid; Golab, Lukasz; Rosenberg, Catherine

    2017-01-01

    Analyzing the impact of pricing policies such as time-of-use (TOU) is challenging in the presence of confounding factors such as weather. Motivated by a lack of consensus and model selection details in prior work, we present a methodology for modelling the effect of weather on residential electricity demand. The best model is selected according to explanatory power, out-of-sample prediction accuracy, goodness of fit and interpretability. We then evaluate the effect of mandatory TOU pricing in a local distribution company in southwestern Ontario, Canada. We use a smart meter dataset of over 20,000 households which is particularly suited to our analysis: it contains data from the summer before and after the implementation of TOU pricing in November 2011, and all customers transitioned from tiered rates to TOU rates at the same time. We find that during the summer rate season, TOU pricing results in electricity conservation across all price periods. The average demand change during on-peak and mid-peak periods is −2.6% and −2.4% respectively. Changes during off-peak periods are not statistically significant. These TOU pricing effects are less pronounced compared to previous studies, underscoring the need for clear, reproducible impact analyses which include full details about the model selection process. - Highlights: • We study models for the effect of weather on residential electricity demand. • We evaluate the effect of mandatory TOU pricing in a local distribution company in Ontario, Canada. • We find the effect of TOU pricing to be less pronounced compared to previous studies.

  3. Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Cruickshank, Robert F.; Henze, Gregor P.; Balaji, Rajagopalan; Hodge, Bri-Mathias S.; Florita, Anthony R.

    2017-04-01

    Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper and lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.

  4. Electricity from waste heat

    Science.gov (United States)

    Larjola, Jaakko; Lindgren, Olli; Vakkilainen, Esa

    In industry and in ships, large amounts of waste heat with quite a high release temperature are produced: examples are combustion gases and the exhaust gases of ceramic kilns. Very often they cannot be used for heating purposes because of long transport distances or because there is no local district heating network. Thus, a practical solution would be to convert this waste heat into electric power. This conversion may be carried out using an ORC-plant (Organic Rankine Cycle). There are probably some twenty ORC-plants in commercial use in the world. They are, however, usually based on conventional power plant technology, and are rather expensive, complicated and may have significant maintenance expenses. In order to obviate these problems, a project was started at Lappeenranta University of Technology at the beginning of 1981 to develop a high-speed, hermetic turbogenerator as the prime mover of the ORC. With this new technology the whole ORC-plant is quite simple, with only one moving part in the power system. It is expected to require very little maintenance, and the calculations made give for it significantly lower specific price than for the conventional technology ORC-plant. Two complete prototypes of the new technology ORC-plant have been built, one to the laboratory, other to industrial use. The nominal output of both is 100 kW electricity. Calculated amortization times for the new ORC-plant range from 2.1 to 6.

  5. Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

    International Nuclear Information System (INIS)

    Kavousian, Amir; Rajagopal, Ram; Fischer, Martin

    2013-01-01

    We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. - Highlights: • Weather, location and floor area are the most important determinants of residential electricity use. • Daily minimum and maximum are explained by different factors. • Number of refrigerators and entertainment devices explain daily minimum the best. • Number of occupants and high-consumption appliances explain daily maximum the best. • Other factors such as energy efficient features and household's socioeconomic status are examined

  6. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  7. Building America Case Study: Side-by-Side Testing of Water Heating Systems: Results from 2013-2014 Evaluation Final Report, Cocoa, FL

    Energy Technology Data Exchange (ETDEWEB)

    Rothgeb, Stacey K [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Colon, C. [BA-PIRC; Martin, E. [BA-PIRC

    2017-08-24

    The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

  8. Building America Case Study: Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation Final Report

    Energy Technology Data Exchange (ETDEWEB)

    C. Colon and E. Martin

    2017-08-24

    The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

  9. Heat-electrical regeneration way to intensive energy saving in an electric arc furnaces

    Science.gov (United States)

    Kartavtcev, S.; Matveev, S.; Neshporenko, E.

    2018-03-01

    Energy saving in steel production is of great significance for its large economical scale of 1500 mil t/year and high-energy consumption. Steady trend of last years is an increase of steel production in electric arc furnaces (EAF) with a very high consumption of electricity up to 750 kWh/ton. The intention to reduce so much energy consumption they can reach by many ways. One of such way is a transforming heat energy of liquid steel to electricity and destine it to steel electric arc process. Under certain conditions, it may lead to “zero” consumption of electric power in the process. The development of these conditions leads to the formation of energy-efficient heat schemes, with a minimum electricity consumption from the external network.

  10. A nonlinear approach to modelling the residential electricity consumption in Ethiopia

    International Nuclear Information System (INIS)

    Gabreyohannes, Emmanuel

    2010-01-01

    In this paper an attempt is made to model, analyze and forecast the residential electricity consumption in Ethiopia using the self-exciting threshold autoregressive (SETAR) model and the smooth transition regression (STR) model. For comparison purposes, the application was also extended to standard linear models. During the empirical presentation of both models, significant nonlinear effects were found and linearity was rejected. The SETAR model was found out to be relatively better than the linear autoregressive model in out-of-sample point and interval (density) forecasts. Results from our STR model showed that the residual variance of the fitted STR model was only about 65.7% of that of the linear ARX model. Thus, we can conclude that the inclusion of the nonlinear part, which basically accounts for the arrival of extreme price events, leads to improvements in the explanatory abilities of the model for electricity consumption in Ethiopia. (author)

  11. A nonlinear approach to modelling the residential electricity consumption in Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Gabreyohannes, Emmanuel [Ethiopian Civil Service College, P.O.Box 5648, Addis Ababa (Ethiopia)

    2010-05-15

    In this paper an attempt is made to model, analyze and forecast the residential electricity consumption in Ethiopia using the self-exciting threshold autoregressive (SETAR) model and the smooth transition regression (STR) model. For comparison purposes, the application was also extended to standard linear models. During the empirical presentation of both models, significant nonlinear effects were found and linearity was rejected. The SETAR model was found out to be relatively better than the linear autoregressive model in out-of-sample point and interval (density) forecasts. Results from our STR model showed that the residual variance of the fitted STR model was only about 65.7% of that of the linear ARX model. Thus, we can conclude that the inclusion of the nonlinear part, which basically accounts for the arrival of extreme price events, leads to improvements in the explanatory abilities of the model for electricity consumption in Ethiopia. (author)

  12. Norwegian households' perception of wood pellet stove compared to air-to-air heat pump and electric heating

    International Nuclear Information System (INIS)

    Sopha, Bertha Maya; Kloeckner, Christian A.; Skjevrak, Geir; Hertwich, Edgar G.

    2010-01-01

    In 2003, the high dependency on electric heating combined with the high electricity price prompted a significant number of Norwegian households to consider alternative heating systems. The government introduced economic support for wood pellet heating and heat pumps. In contrast to the fast growing heat pump market, this financial support has not resulted in a widespread adoption of wood pellet heating. This paper studies factors that influence the choice of heating system based on Norwegian households' perceptions. Electric heating, heat pump and wood pellet heating were compared, with a special focus on wood pellet heating. This study was conducted as a questionnaire survey on two independent samples. The first sample consisted of 188 randomly chosen Norwegian households, mainly using electric heating; the second sample consisted of 461 households using wood pellet heating. Our results show that socio-demographic factors, communication among households, the perceived importance of heating system attributes, and the applied decision strategy all influence the Norwegian homeowners. The significance of these factors differs between the two samples and the preferred type of anticipated future heating system. Strategies for possible interventions and policy initiatives are discussed.

  13. Increasing economic benefits by load-shifting of electrical heat pumps

    OpenAIRE

    Laveyne, Joannes; Zwaenepoel, Brecht; Van Eetvelde, Greet; Vandevelde, Lieven

    2014-01-01

    Electrical heating is still widely used in the process industry. While the use of immersion heaters for the production of hot water or steam is declining, the adoption rate of electrical heat pumps is increasing rapidly. Heat pumps show great flexibility and potential for energy savings, e.g. through low temperature waste heat recuperation. In combination with thermal storage they also allow for load shifting. Because their main power source is electricity, which up to now cannot be stored ef...

  14. Wright tariffs in the Spanish electricity industry: the case of residential consumption

    International Nuclear Information System (INIS)

    Castro-Rodriguez, F.

    1999-01-01

    In this paper a capacity price model is developed for the Spanish electricity industry which allows the presentation of the Spanish utilization level tariffs as an example of duration tariffs (Wright tariffs) when duration is approximated by the ratio of consumption to power used. Using this model and data on the residential consumption of electricity, several optimal two-part tariffs are computed, considering different hypothesis on the configuration of the generating equipment. It has been found that the optimal tariff maintaining universal service increases welfare if the generating equipment and the output assignment to the different technologies are taken as given. Furthermore, if the regulator is concerned not only with efficiency, but also with distributive issues, then welfare losses associated with the existing regulatory regime are even larger

  15. Greenhouse gas abatement cost curves of the residential heating market. A microeconomic approach

    International Nuclear Information System (INIS)

    Dieckhoener, Caroline; Hecking, Harald

    2012-01-01

    In this paper, we develop a microeconomic approach to deduce greenhouse gas abatement cost curves of the residential heating sector. By accounting for household behavior, we find that welfare-based abatement costs are generally higher than pure technical equipment costs. Our results are based on a microsimulation of private households' investment decision for heating systems until 2030. The households' investment behavior in the simulation is derived from a discrete choice estimation which allows investigating the welfare costs of different abatement policies in terms of the compensating variation and the excess burden. We simulate greenhouse gas abatements and welfare costs of carbon taxes and subsidies on heating system investments until 2030 to deduce abatement curves. Given utility maximizing households, our results suggest a carbon tax to be the welfare efficient policy. Assuming behavioral misperceptions instead, a subsidy on investments might have lower marginal greenhouse gas abatement costs than a carbon tax.

  16. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  17. Electrical energy use in different heating systems for early weaned piglets

    Energy Technology Data Exchange (ETDEWEB)

    Sarubbi, J. [Federal Univ. of Santa Maria, Palmeira das Missoes, RS (Brazil). Dept. of Animal Science; Campinas State Univ., Sao Paulo (Brazil). College of Agricultural Engineering; Rossi, L.A.; Moura, D.J.; Oliveira, R.A.; David, E. [Campinas State Univ., Sao Paulo (Brazil). College of Agricultural Engineering

    2010-07-01

    This study compared the electrical energy use and thermal comfort conditions associated with 3 heating technologies used in piglet farms. Heating systems for piglets in nursery and farrowing can be improved to conserve energy without affecting the welfare of the animals. The evaluation was conducted at a commercial farm in a subtropical climate area of Brazil. Each treatment involved 150 weaned piglets at 21 days-old. The systems were designed to keep the piglets at 28 to 30 degrees C for 14 days. Suspended electrical resistors, heated floors and convection heating were the 3 heating technologies examined during this study which evaluated the electrical energy consumption, maximum power demand requirements and dry-bulb temperature. The study also assessed the specific consumption in terms of kWh/kg of live produced body mass as well as the efficiency of heating system in terms of degrees C per cubic metre of air. In terms of electrical energy use, the best heating system was the heated floor. However, the electrical resistance heating system was the best in terms of thermal comfort.

  18. Thermal energy storage for electricity-driven space heating in a day-ahead electricity market

    DEFF Research Database (Denmark)

    Pensini, Alessandro

    2012-01-01

    Thermal Energy Storage (TES) in a space heating (SH) application was investigated. The study aimed to determine the economic benefits of introducing TES into an electricity-driven SH system under a day-ahead electricity market. The performance of the TES was assessed by comparing the cost...... of electricity in a system with a TES unit to the case where no storage is in use and the entire heat requirement is fulfilled by purchasing electricity according to the actual load. The study had two goals: 1. Determining how the size – in terms of electricity input (Pmax) and energy capacity (Emax...

  19. Historic trends in the residential sector

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the OECD countries, income-driven growth in equipment ownership (heating, appliances) and home size drove household energy use up, but higher energy prices and conservation programs had a restraining effect. The results were mixed, with consumption per capita significantly lower in a few countries (United States, France), but higher in others. There was a significant decline in the intensity of space heating (30-40%) and a small decline in the intensity of electric applicances. Changes in the size and features of many appliances offset much of the improvement in technical energy efficiency. Not all of the decline in heating intensity was a result of technical change; the author estimates that about 25% was caused by change in heating behavior. In all, there were significant improvements in efficiency, but these were offset somewhat by structural change. In the Former East Bloc, there is far less residential space and amenity than in OECD countries, and efficiency of space heating and water heating is low, in part due to lake of energy pricing. Electric appliances are simple and relatively inefficient. Unlike in the OECD countries, there is little sign of improved efficiency in the 1970s and 1980s. In the LDCs, patterns of energy use, and changes in them, are very different in rural and urban areas, and vary among regions as well. Biomass is still the dominant fuel in rural areas. In urban areas, Western-like patterns of electricity (and even gas) use have emerged for appliances, cooking, and water heating among the affluent, and TV and refrigerators have become more common among the less-affluent. In many countries, especially in Southeast Asia, there has been very rapid growth in ownership of appliances. Most appliances are cheaply made and inefficient compared to similar appliances sold in the OECD countries, though there are signs of some improvement in the past decade. 16 refs., 11 figs., 9 figs

  20. Heat management of electric-powered vehicles; Thermomanagement von Elektro-Fahrzeugen

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Markus; Koppe, Theresia [Webasto AG, Stockdorf (Germany)

    2010-07-01

    In contrast to a driving operation with combustion engine has in the purely electrical driving conditions only a fraction of the heat losses available from the power train components required for interior heating. Already at an ambient temperature of +10 C additional heating action is needed to prevent condensation on the vehicle windscreen and for a comfortable interior climate. An additional electrical heater strains the resource Battery and thus reduces the driving range for the electric drive depending on the driving cycle and environmental conditions up to 50%. A solution to this dilemma is a burner heating system with a neutral emission combustion process, uses the highest efficiency to direct the required heat energy to heat the vehicle. (orig.)

  1. Experiences with field tests: Ground coupled heat pumps in small residential buildings; Feldtesterfahrungen. Erdgekoppelte Waermepumpen in kleineren Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Wapler, Jeannette; Guenther, Danny; Miara, Marek [Fraunhofer-Institut fuer Solare Energiesysteme ISE/Thermal Systems and Buildings, Freiburg (Germany)

    2012-07-01

    In the context of two research projects, the Fraunhofer Institute for Solar Energy Systems (Freiburg, Federal Republic of Germany) has surveyed a large number of heat pumps in actual application. In particular, heat pumps in small residential buildings (single-family houses) were examined for new and existing buildings. In addition to the achieved performance factors the temperature profile of the heat sink and heat source was recorded. This temperature profile was evaluated separately for systems with geothermal collectors and systems with geothermal probes. The theoretical assumptions could be confirmed. Influences during the installation, commissioning and operation are identified.

  2. Wind Turbines and Heat Pumps. Balancing wind power fluctuations using flexible demand

    International Nuclear Information System (INIS)

    Warmer, C.J.; Hommelberg, M.P.F.; Kamphuis, I.G.; Derszi, Z.; Kok, J.K.

    2007-01-01

    In order to overcome portfolio imbalance for traders of variable power from wind we have built an 'Imbalance Reduction System' (IRS) and performed a real-world field test with it, in which imbalance is minimized within a real-time electricity market portfolio, consisting of wind power and industrial and residential consumers and producers (Combined Heat and Power for district heating; residential heat pumps; industrial cold store; emergency generators). IRS uses the PowerMatcher concept, a coordination system for supply and demand of electricity in a which multi-agent system is combined with microeconomic principles. IRS appears to offer opportunities for embedding less predictable generators such as wind power more smoothly in the portfolio. We describe the context and operation of the Imbalance Reduction System and discuss a number of results from the performed field test. Also we introduce a business model for the balance responsible party, based on the e3-value method

  3. Actual performance and economic feasibility of residential solar water heaters

    International Nuclear Information System (INIS)

    Anhalt, J.

    1987-01-01

    Four residential solar water heaters currently available on the Brazilian market have been evaluated to their possible use for substituting the common electric shower head. The tests were carried out with the solar systems mounted side by side on an artificial roof. The hot water demand was simulated following a consumer profile which represents a Brazilian family with an income of seven minimum salaries. The data, which was collected automatically and presented in the form of graphs and tables, shows that an optimized solar water heater could save as much as 65% of the energy demand for residential water heating in the state of Sao Paulo. An economical study concludes that the installation and maintenance of such a solar system is feasible if long term financing is available. (author)

  4. Pattern analysis and suggestion of energy efficiency retrofit for existing residential buildings in China's northern heating region

    International Nuclear Information System (INIS)

    Lv Shilei; Wu Yong; Sun Jinying

    2009-01-01

    In China, Energy Efficiency Retrofit for Existing Residential Buildings (EERFERB) is faced with a fast development status. The Central Government decided to prompt the retrofit of 1.5x10 8 m 2 existing residential buildings in China's northern heating region during the '11th Five-Years Plan'. But, at present, the relative incentive policies and measurements are very insufficient. Especially, on the aspect of the retrofit pattern about the organization, retrofit content, investing and financing mode, the policy and management and other factors, no existing successful one can be spreaded into the whole northern heating region. This research not only analyzed the foreign advanced methods, drew lessons from their retrofit in Germany and Poland, but contrasted and analyzed energy efficiency retrofit demonstrations from Harbin, Tianjin, Tangshan and Baotou in China to get our domestic successful patterns and experience. Finally, some recommended retrofit patterns are presented, which can be applied for the instruction and decision-making for the Chinese local governments.

  5. Experimental determination of local heat flux variation in an electrically heated BR-2 rod

    International Nuclear Information System (INIS)

    Meyer, L.; Merschroth, F.

    1977-08-01

    The installation of thermocouples within the cladding of an electrically heated BR-2 rod might cause local variations of heat flux. In order to detect a resulting temperature variation at the outer surface, experiments with a single electrically heated rod with heat fluxes up to 30.80 W/cm 2 and heat transfer coefficients up to 1000 W/m 2 K by forced convection in air were conducted. The surface temperatures were measured with an optical pyrometer. The experiment showed about 0.6% variation in the surface temperature. An analysis with the TAC2D-code shows that local variation in the heat flux under these conditions is less than 1.2%. (orig.) [de

  6. Potential Energy Flexibility for a Hot-Water Based Heating System in Smart Buildings Via Economic Model Predictive Control

    DEFF Research Database (Denmark)

    Ahmed, Awadelrahman M. A.; Zong, Yi; Mihet-Popa, Lucian

    2017-01-01

    This paper studies the potential of shifting the heating energy consumption in a residential building to low price periods based on varying electricity price signals suing Economic Model Predictive Control strategy. The investigated heating system consists of a heat pump incorporated with a hot...... water tank as active thermal energy storage, where two optimization problems are integrated together to optimize both the heat pump electricity consumption and the building heating consumption. A sensitivity analysis for the system flexibility is examined. The results revealed that the proposed...

  7. Retrofit energy conservation in residential buildings in southern California

    Science.gov (United States)

    Turner, R. H.; Birur, G. C.; Daksla, C.

    1982-01-01

    The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

  8. Residual heat use generated by a 12 kW fuel cell in an electric vehicle heating system

    International Nuclear Information System (INIS)

    Colmenar-Santos, Antonio; Alberdi-Jiménez, Lucía; Nasarre-Cortés, Lorenzo; Mora-Larramona, Joaquín

    2014-01-01

    A diesel or gasoline vehicle heating is produced by the heat of the engine coolant liquid. Nevertheless, electric vehicles, due to the fact that electric motor transform directly electricity into mechanical energy through electromagnetic interactions, do not generate this heat so other method of providing it has to be developed. This study introduces the system developed in a fuel cell electric vehicle (lithium-ion battery – fuel cell) with residual heat use. The fuel cell electric vehicle is driven by a 12 kW PEM (proton exchange membrane) fuel cell. This fuel cell has an operating temperature around 50 °C. The residual heat generated was originally wasted by interaction with the environment. The new developed heating system designed integrates the heat generated by the fuel cell into the heating system of the vehicle, reducing the global energy consumption and improving the global efficiency as well. - Highlights: • Modification of heating system was done by introducing the residual heat from fuel cell. • Maximum heat achieved by the heating radiator of 9.27 kW. • Reduction of the heat dissipation by the fuel cell cooling system 1.5 kW. • Total efficiency improvement of 20% with an autonomy increase of 21 km

  9. Integration of the heat and refrigeration sector into the electricity market model PowerFlex for the analysis of sector encompasing effects on the climate protection goals and EE integration. Scientific final report - actualized version

    International Nuclear Information System (INIS)

    Koch, Matthias; Hesse, Tilman; Kenkmann, Tanja

    2017-01-01

    The report covers the following issues: (i) Detailed description of the heat sector and its coupling to the electricity sector within the electricity market model PowerFlex: provate heat demand, derivation of heat load profiles, development of a technology and energy carrier mix, data inputs for the electricity market regulation. (ii) Creation of an empirically based data basis for the air conditioning of building, its coupling to the electricity system and derivation of recommendations: preparation of a representative empirical determination of the status quo and the factors that provoke private households to install air conditions, effective parameters for the development of energy demand for air conditioning of residential homes, preparation of a data input for the electricity market model - methodology and results. (iii) Preparation of generic renewable energy supply time series with different levels of fluctuation: Methodology of the renewable energy profile calculation, calculation of the supply profile for photovoltaics, calculation of the supply profile for onshore wind and offshore wind. (iv) Extension of the electricity market model PowerFlex to PowerFlex-heat and cold for the sector encompassing scenario analysis: extension of the module to cogeneration power plants, power-to-heat and power-to-gas for the detailed description of the heat sector, extension of the module for load management, scenarios and interpretation of the results.

  10. Comparison study of the technical characteristics and financial analysis of electric battery storage systems for residential grid

    Science.gov (United States)

    Palivos, Marios; Vokas, Georgios A.; Anastasiadis, Anestis; Papageorgas, Panagiotis; Salame, Chafic

    2018-05-01

    One of the major energy issues of our days is reliable and effective energy generation and supply of electricity grids. In recent years there has been experienced a rapid development and implementation of Renewable Energy Sources (RES) worldwide. On one hand, many Gigawatts of grid-connected renewables are being installed and on the other many Megawatts of hybrid renewable systems for residential use are being installed making use of electric battery systems, in order to cover all daily energy and power needs during. New types of batteries are being developed and many companies have made great progress providing a variety of electricity storage products. The purpose of this research is firstly to highlight the necessity and also the importance of the use of energy storage systems and secondly, through detailed technical and financial simulation analysis using HOMER Pro-optimization software, to compare the technical characteristics and performance of energy storage systems by various leading companies when installed in a residential renewable energy system with a specific load and at the same time to provide the most efficient system economically. Results concerning the operation and the choice of a storage system are derived.

  11. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In this paper, an effective energy management system (EMS) for application in integrated building and microgrid system is introduced and implemented as a multi-objective optimization problem. The proposed architecture covers different key modelling aspects such as distributed heat and electricity......’s objectives, the effectiveness and applicability of the proposed model is studied and validated compared to the existing residential EMSs. The simulation results demonstrate that the proposed EMS has the capability not only to conserve energy in sustainable homes and microgrid system and to reduce energy...

  12. Comparison of Advanced Residential Water Heating Technologies in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Fang, X.; Wilson, E.

    2013-05-01

    Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

  13. Novel approaches for an enhanced geothermal development of residential sites

    Science.gov (United States)

    Schelenz, Sophie; Firmbach, Linda; Shao, Haibing; Dietrich, Peter; Vienken, Thomas

    2015-04-01

    An ongoing technological enhancement drives an increasing use of shallow geothermal systems for heating and cooling applications. However, even in areas with intensive shallow geothermal use, planning of geothermal systems is in many cases solely based on geological maps, drilling databases, and literature references. Thus, relevant heat transport parameters are rather approximated than measured for the specific site. To increase the planning safety and promote the use of renewable energies in the domestic sector, this study investigates a novel concept for an enhanced geothermal development of residential neighbourhoods. This concept is based on a site-specific characterization of subsurface conditions and the implementation of demand-oriented geothermal usage options. Therefore, an investigation approach has been tested that combines non-invasive with minimum-invasive exploration methods. While electrical resistivity tomography has been applied to characterize the geological subsurface structure, Direct Push soundings enable a detailed, vertical high-resolution characterization of the subsurface surrounding the borehole heat exchangers. The benefit of this site-specific subsurface investigation is highlighted for 1) a more precise design of shallow geothermal systems and 2) a reliable prediction of induced long-term changes in groundwater temperatures. To guarantee the financial feasibility and practicability of the novel geothermal development, three different options for its implementation in residential neighbourhoods were consequently deduced.

  14. Optimal load scheduling in commercial and residential microgrids

    Science.gov (United States)

    Ganji Tanha, Mohammad Mahdi

    Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.

  15. Indoor unit for electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  16. Survey of residential heat pump owner experience in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Unsoy, J

    1985-11-11

    Heat pump owners in 7 Canadian cities were surveyed to establish installation costs, repair costs and frequencies, and customer satisfaction with heat pump systems as a function of region, installing contractor, manufacturer, model, year of installation and system type. The following summarizes the major findings of the study. Most Canadian heat pumps are retrofit installations in existing homes. The majority of these heat pumps have either supplemented or replaced an oil furnace. The average age of heat pumps is 2.5 years. The median size of heat pumps installed is 2.5 tons. The three most popular brands by order of prevalence are York, Carrier and General Electric. Only about one-fifth of heat pump owners have purchased service contracts. Two-thirds of the heat pumps have never needed repairs. Eighty-three percent of heat pump owners have never incurred any repair costs; and of those that have, about half spent $100 or less. The most frequent repair problems are refrigerant leaks followed by relays and controls. Corrective actions average about 0.3 per unit year. The owners' evaluation of comfort from their heat pump is generally favourable. About 12% of the owners find the outdoor unit noisy and 10% feel maintenance costs are at a disadvantage. Overall, only 7% of heat pump owners indicated that they would not install a heat pump in their next house. Most heat pump owners are satisfied with their heat pump brand and installer. Owners with systems installed in newer homes are more satisfied with their heat pumps than those who have installed heat pumps in older homes. 3 figs., 93 tabs.

  17. Economic analysis of second use electric vehicle batteries for residential energy storage and load-levelling

    International Nuclear Information System (INIS)

    Heymans, Catherine; Walker, Sean B.; Young, Steven B.; Fowler, Michael

    2014-01-01

    The reuse of Li-ion EV batteries for energy storage systems (ESS) in stationary settings is a promising technology to support improved management of demand and supply of electricity. In this paper, MatLAB simulation of a residential energy profile and regulated cost structure is used to analyze the feasibility of and cost savings from repurposing an EV battery unit for peak-shifting. in situ residential energy storage can contribute to the implementation of a smart grid by supporting the reduction of demand during typical peak use periods. Use of an ESS increases household energy use but potentially improves economic effectiveness and reduces greenhouse gas emissions. The research supports the use of financial incentives for Li-ion battery reuse in ESS, including lower energy rates and reduced auxiliary fees. - Highlights: • EV Li-ion batteries can be reused in stationary energy storage systems (ESS). • A single ESS can shift 2 to 3 h of electricity used in a house. • While energy use increases, potential economic and environmental effectiveness improve. • ESS supports smart grid objectives. • Incentives like reduced fees are needed to encourage implementation of Li-ion battery ESS

  18. Experimental investigation on an integrated thermal management system with heat pipe heat exchanger for electric vehicle

    OpenAIRE

    Zou, Huiming; Wang, Wei; Zhang, Guiying; Qin, Fei; Tian, Changqing; Yan, Yuying

    2016-01-01

    An integrated thermal management system combining a heat pipe battery cooling/preheating system with the heat pump air conditioning system is presented to fulfill the comprehensive energy utilization for electric vehicles. A test bench with battery heat pipe heat exchanger and heat pump air conditioning for a regular five-chair electric car is set up to research the performance of this integrated system under different working conditions. The investigation results show that as the system is d...

  19. Heating and cooling distribution in residential and non-residential premises; Distribution av kyla och vaerme i bostaeder och lokaler

    Energy Technology Data Exchange (ETDEWEB)

    Jardeby, Aasa; Soleimani-Mohseni, Mohsen; Axell, Monica

    2009-08-15

    The building sector accounts for approximately 40% of energy use in Europe, and about the same ratio applies to Sweden. Distribution systems for heating and cooling are an important part of the building's heating and cooling systems. The desired indoor climate can not be achieved without a properly sized distribution system. The aim of this report is to highlight the opportunities for energy efficiency with a properly designed distribution system by identifying and comparing different system solutions for the distribution of heating and cooling in residential and non-residential premises. The report presents which affect various factors have on the system as a whole, such as media selection, sizing of the piping system, heat transfer surface and regulation and control strategies. It also gives a picture of the possibilities and limitations of different needs and requirements of indoor environment (such as requirements for the thermal environment, air quality, noise, space, etc.). By having a systems perspective at the heating and/or cooling, energy efficiency is achieved. There are possibilities of big gains with a systems approach, since the choices made in designing a distribution system, affects many other parts of the system and there is a risk of poor optimization. A first step in reducing the energy use is to reduce the cooling and heating loads in the building. A heating and cooling systems should be designed properly so as not to consume excessive energy. There are other strategies to reduce energy consumption, e.g. by allowing more variations in temperature. However, it is important that it is not at the expense of the needs and requirements of the building. If the building has a cooling requirement that can be covered by the air flow required for ventilation it is recommended to provide under tempered air. In addition, the air can be cooled by free cooling from outside over large parts of the year. If the building has greater cooling requirements

  20. Electric radiant heating : a hot profitable idea

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2006-09-15

    Due to the high cost of heating oil, natural gas and propane, floor mounted radiant heating systems are now proving to be a cost effective method of heating homes. The systems provide evenly distributed heat across the entire floor area. Unlike hydronic floor systems, radiant floor systems require no maintenance, and are easy to control because no mechanical rooms or boilers are required. The system is comprised of a series of resistant heating cables, a thermostat, and a solid state relay. The cables are installed in a poured concrete pad. Separate temperature control devices are used to heat individual areas of floorspace. Building automation systems can also control the heating system by using simple ambient air- and floor-mounted sensors in conjunction with relays to energize the heating cables. The cost of thermostats and heating cables to heat a standard 2000 square foot home are estimated at $9000.00, with an additional 64 hours of installation costs. It was noted that the systems may prove to be less costly in the long-term than hydronic systems, which require additional boilers, pumps and water treatments. Electric radiant heating can be an even more cost-effective application when used with thermal storage heating applications that use lower-cost off-peak electricity to generate and store heat in concrete floor slabs or ceramic bricks contained in insulated cabinets. It was concluded that radiant heating systems are a viable and cost-effective alternative to expensive hydronic systems, which are costly to install and maintain. 4 figs.

  1. Energy management strategies for combined heat and electric power micro-grid

    Directory of Open Access Journals (Sweden)

    Barbarić Marina

    2016-01-01

    Full Text Available The increasing energy production from variable renewable energy sources such as wind and solar has resulted in several challenges related to the system reliability and efficiency. In order to ensure the supply-demand balance under the conditions of higher variability the micro-grid concept of active distribution networks arising as a promising one. However, to achieve all the potential benefits that micro-gird concept offer, it is important to determine optimal operating strategies for micro-grids. The present paper compares three energy management strategies, aimed at ensuring economical micro-grid operation, to find a compromise between the complexity of strategy and its efficiency. The first strategy combines optimization technique and an additional rule while the second strategy is based on the pure optimization approach. The third strategy uses model based predictive control scheme to take into account uncertainties in renewable generation and energy consumption. In order to compare the strategies with respect to cost effectiveness, a residential micro-grid comprising photovoltaic modules, thermal energy storage system, thermal loads, electrical loads as well as combined heat and power plant, is considered.

  2. Techno-economic feasibility of hybrid diesel/PV/wind/battery electricity generation systems for non-residential large electricity consumers under southern Iran climate conditions

    International Nuclear Information System (INIS)

    Baneshi, Mehdi; Hadianfard, Farhad

    2016-01-01

    Highlights: • A hybrid electricity generation system for a large electricity consumer was studied. • The PV and wind electricity potentials under given climate conditions were evaluated. • Technical, economical, and environmental issues of different systems were discussed. • The optimum configuration of components was obtained. • The impacts of governmental incentives on economic viability of systems were examined. - Abstract: This paper aims to study the techno-economical parameters of a hybrid diesel/PV/wind/battery power generation system for a non-residential large electricity consumer in the south of Iran. As a case study, the feasibility of running a hybrid system to meet a non-residential community’s load demand of 9911 kWh daily average and 725 kW peak load demand was investigated. HOMER Pro software was used to model the operation of the system and to identify the appropriate configuration of it based on comparative technical, economical, and environmental analysis. Both stand alone and grid connected systems were modeled. The impacts of annual load growth and governmental energy policies such as providing low interest loan to renewable energy projects, carbon tax, and modifying the grid electricity price on viability of the system were discussed. Results show that for off-grid systems the cost of electricity (COE) and the renewable fraction of 9.3–12.6 ₵/kWh and 0–43.9%, respectively, are achieved with photovoltaic (PV) panel, wind turbine, and battery sizes of 0–1000 kW, 0–600 kW, and 1300 kWh, respectively. For on grid systems without battery storage the range of COE and renewable fraction are 5.7–8.4 ₵/kWh and 0–53%, respectively, for the same sizes of PV panel and wind turbine.

  3. Thermalhydraulic behavior of electrically heated rod during a critical heat flux transient

    International Nuclear Information System (INIS)

    Lima, Rita de Cassia Fernandes de; Carajilescov, Pedro

    1997-01-01

    In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed using electrically heated rods to simulate operational and accidental conditions of nuclear fuel rods. In the present work, a theoretical analysis of the drying and rewetting front propagation is performed during a critical heat flux experiment, starting with the application of slope of electrical power from steady state condition. After the occurrence of critical heat flux, the drying front propagation is predicted. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. Studies done with several values of coolant mass flow rate show that this variable has more influence on the drying front velocity than on the rewetting one. (author)

  4. Cost of electricity from small scale co-generation of electricity and heat

    Energy Technology Data Exchange (ETDEWEB)

    Kjellstroem, Bjoern

    2012-07-15

    There is an increasing interest in Sweden for using also small heat loads for cogeneration of electricity and heat. Increased use of small CHP-plants with heat supply capacities from a few 100 kW(h) up to 10 MW(h) cannot change the structure of the electricity supply system significantly, but could give an important contribution of 2 - 6 TWh(e) annually. The objective of this study was to clarify under what conditions electricity can be generated in small wood fired CHP-plants in Sweden at costs that can compete with those for plants using fossil fuels or nuclear energy. The capacity range studied was 2 - 10 MW(h). The results should facilitate decisions about the meaningfulness of considering CHP as an option when new heat supply systems for small communities or sawmills are planned. At the price for green certificates in Sweden, 250 - 300 SEK/MWh(e), generation costs in small wood fired CHP-plants should be below about 775 SEK/MWh(e) to compete with new nuclear power plants and below about 925 SEK/MWh(e) to compete with generation using fossil fuels.

  5. Residential energy efficiency: Progress since 1973 and future potential

    Science.gov (United States)

    Rosenfeld, Arthur H.

    1985-11-01

    Today's 85 million U.S. homes use 100 billion of fuel and electricity (1150/home). If their energy intensity (resource energy/ft2) were still frozen at 1973 levels, they would use 18% more. With well-insulated houses, need for space heat is vanishing. Superinsulated Saskatchewan homes spend annually only 270 for space heat, 150 for water heat, and 400 for appliances, yet they cost only 2000±1000 more than conventional new homes. The concept of Cost of Conserved Energy (CCE) is used to rank conservation technologies for existing and new homes and appliances, and to develop supply curves of conserved energy and a least cost scenario. Calculations are calibrated with the BECA and other data bases. By limiting investments in efficiency to those whose CCE is less than current fuel and electricity prices, the potential residential plus commercial energy use in 2000 AD drops to half of that estimated by DOE, and the number of power plants needed drops by 200. For the whole buildings sector, potential savings by 2000 are 8 Mbod (worth 50B/year), at an average CCE of 10/barrel.

  6. Efficiency Analysis of Independent and Centralized Heating Systems for Residential Buildings in Northern Italy

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2011-11-01

    Full Text Available The primary energy consumption in residential buildings is determined by the envelope thermal characteristics, air change, outside climatic data, users’ behaviour and the adopted heating system and its control. The new Italian regulations strongly suggest the installation of centralized boilers in renovated buildings with more than four apartments. This work aims to investigate the differences in primary energy consumption and efficiency among several independent and centralized heating systems installed in Northern Italy. The analysis is carried out through the following approach: firstly building heating loads are evaluated using the software TRNSYS® and, then, heating system performances are estimated through a simplified model based on the European Standard EN 15316. Several heating systems have been analyzed, evaluating: independent and centralized configurations, condensing and traditional boilers, radiator and radiant floor emitters and solar plant integration. The heating systems are applied to four buildings dating back to 2010, 2006, 1960s and 1930s. All the combinations of heating systems and buildings are analyzed in detail, evaluating efficiency and primary energy consumption. In most of the cases the choice between centralized and independent heating systems has minor effects on primary energy consumption, less than 3%: the introduction of condensing technology and the integration with solar heating plant can reduce energy consumption by 11% and 29%, respectively.

  7. Higher-capacity lithium ion battery chemistries for improved residential energy storage with micro-cogeneration

    International Nuclear Information System (INIS)

    Darcovich, K.; Henquin, E.R.; Kenney, B.; Davidson, I.J.; Saldanha, N.; Beausoleil-Morrison, I.

    2013-01-01

    Highlights: • Characterized two novel high capacity electrode materials for Li-ion batteries. • A numerical discharge model was run to characterize Li-ion cell behavior. • Engineering model of Li-ion battery pack developed from cell fundamentals. • ESP-r model integrated micro-cogeneration and high capacity Li-ion storage. • Higher capacity batteries shown to improve micro-cogeneration systems. - Abstract: Combined heat and power on a residential scale, also known as micro-cogeneration, is currently gaining traction as an energy savings practice. The configuration of micro-cogeneration systems is highly variable, as local climate, energy supply, energy market and the feasibility of including renewable type components such as wind turbines or photovoltaic panels are all factors. Large-scale lithium ion batteries for electrical storage in this context can provide cost savings, operational flexibility, and reduced stress on the distribution grid as well as a degree of contingency for installations relying upon unsteady renewables. Concurrently, significant advances in component materials used to make lithium ion cells offer performance improvements in terms of power output, energy capacity, robustness and longevity, thereby enhancing their prospective utility in residential micro-cogeneration installations. The present study evaluates annual residential energy use for a typical Canadian home connected to the electrical grid, equipped with a micro-cogeneration system consisting of a Stirling engine for supplying heat and power, coupled with a nominal 2 kW/6 kW h lithium ion battery. Two novel battery cathode chemistries, one a new Li–NCA material, the other a high voltage Ni-doped lithium manganate, are compared in the residential micro-cogeneration context with a system equipped with the presently conventional LiMn 2 O 4 spinel-type battery

  8. Electric radiant heating or, why are plumbers getting our work?

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech, Toronto, ON (Canada)

    2009-02-15

    Electric radiant heating (ERH) technologies are now being installed in floors as a means of reducing heating costs. The radiant installations have seen a large increase in sales over the last decade, and are now being used in commercial applications. Sales of hydronic ERH systems have increased by 24 per cent over the last year. ERH systems are energy efficient and do not cause drafts. The systems consist of resistant heating cables installed within the floors of a room. The cables are supplied as loose cables and tracks with predetermined spacings or rugged, heavier cable that can be stapled onto wooden subfloors. Program temperature setbacks can be applied on a room-by-room basis. Electric thermal storage systems allow building owners to store heat in the floors and are ideal for use in combination with time-of-use electric metering. Some electric utilities are now promoting the use of electric thermal storage in order to reduce demand during peak times. Thermostats used with the systems should have floor sensors and ambient air sensors to control space heating in conjunction with the floor sensor. It was concluded that electrical contractors who gain knowledge in the application and installation of the systems will tap into a growing revenue stream. 5 figs.

  9. Electric radiant heating or, why are plumbers getting our work?

    International Nuclear Information System (INIS)

    Lemieux, G.

    2009-01-01

    Electric radiant heating (ERH) technologies are now being installed in floors as a means of reducing heating costs. The radiant installations have seen a large increase in sales over the last decade, and are now being used in commercial applications. Sales of hydronic ERH systems have increased by 24 per cent over the last year. ERH systems are energy efficient and do not cause drafts. The systems consist of resistant heating cables installed within the floors of a room. The cables are supplied as loose cables and tracks with predetermined spacings or rugged, heavier cable that can be stapled onto wooden subfloors. Program temperature setbacks can be applied on a room-by-room basis. Electric thermal storage systems allow building owners to store heat in the floors and are ideal for use in combination with time-of-use electric metering. Some electric utilities are now promoting the use of electric thermal storage in order to reduce demand during peak times. Thermostats used with the systems should have floor sensors and ambient air sensors to control space heating in conjunction with the floor sensor. It was concluded that electrical contractors who gain knowledge in the application and installation of the systems will tap into a growing revenue stream. 5 figs

  10. Combined heat and power and thermally insulating measures in residential housing stock; Kraft-Waerme-Kopplung und Daemmmassnahmen im Wohngebaeudebestand

    Energy Technology Data Exchange (ETDEWEB)

    Buller, Michael [Gas- und Waerme-Institut Essen e.V., Essen (Germany)

    2013-02-15

    The author of the contribution under consideration reports on the economic, ecologic and primary energetic potential of micro-combined heat and power (micro-CHP) in the residential housing stock under consideration of possible correlations between CHP and thermally insulating measures.

  11. Household preferences of hybrid home heating systems – A choice experiment application

    International Nuclear Information System (INIS)

    Ruokamo, Enni

    2016-01-01

    The residential heating sector presents considerable energy savings potential, as numerous heating solutions for reducing electricity consumption and utilizing renewable energy sources are available in the market. The aim of this paper is to examine determinants of household heating system choices and to use this information for policy planning purposes. This paper investigates residential homeowner attitudes regarding innovative hybrid home heating systems (HHHS) with choice experiment. Heating system scenarios are designed to represent the most relevant primary and supplementary heating alternatives currently available in Finland. The choice sets include six main heating alternatives (district heat, solid wood, wood pellet, electric storage heating, ground heat pump and exhaust air heat pump) that are described by five attributes (supplementary heating systems, investment costs, operating costs, comfort of use and environmental friendliness). The results imply that HHHSs generally appear to be accepted among households; however, several factors affect perceptions of these technologies. The results reveal differing household attitudes toward the main heating alternatives and show that such views are affected by socio-demographic characteristics (age, living environment, education, etc.). The results suggest that households view supplementary heating systems (especially solar-based) favorably. The other attributes studied also play a significant role in decision making. - Highlights: •Study of hybrid heating where supplementary and main heating systems are combined. •Choice experiment is applied to study the determinants of hybrid heating adoption. •Hybrid heating appears to be generally accepted among households. •Households exhibit differing attitudes toward hybrid heating. •Policy makers should not underestimate the potential of hybrid heating.

  12. Trends of multiple air pollutants emissions from residential coal combustion in Beijing and its implication on improving air quality for control measures

    Science.gov (United States)

    Xue, Yifeng; Zhou, Zhen; Nie, Teng; Wang, Kun; Nie, Lei; Pan, Tao; Wu, Xiaoqing; Tian, Hezhong; Zhong, Lianhong; Li, Jing; Liu, Huanjia; Liu, Shuhan; Shao, Panyang

    2016-10-01

    for residential heating can be replaced with gas-burning wall-heaters, ground-source heat pumps, solar energy and electricity. In areas with inadequate clean energy sources, low-sulfur coal should be used instead of the traditional raw coal with high sulfur and ash content, thereby slightly reducing the emissions of PM, SO2, CO and other toxic pollutants.

  13. Analysis of rural residential energy consumption and corresponding carbon emissions in China

    International Nuclear Information System (INIS)

    Yao Chunsheng; Chen Chongying; Li Ming

    2012-01-01

    The analysis of rural residential energy consumption in China from 2001 to 2008 and corresponding impacts on climate change is presented in the paper. It is found that rural residential energy consumption has shown obvious transition from non-commercial energy to commercial energy. The percentage of biomass energy consumption dropped from 81.5% in 2001 to 70.9% in 2008, while the percentage of commercial energy increased from 17.1% to 25.1%. Besides, other renewable energy increased very fast with annual growth rate of 19.8%. Correspondingly, total CO 2 emissions from rural residential energy consumption had significant increase from 152.2 Million tons in 2001 to 283.6 Million tons in 2008. The annual growth rate of per capita CO 2 emissions was nearly 2 times faster than that of urban area. The major driving force for the consumption of commercial energy was the income of rural farmers, while strong rural energy policies supported the development of renewable energy. To satisfy the goals of energy supply and CO 2 emissions reduction in rural areas, it is advised to change the energy structure and improve the energy efficiency, such as to generate electricity using renewable technologies and to replace coal with modern biomass energy for cooking and heating. - Highlights: ► This study analyzed rural residential energy consumption in China 2001–2008. ► It shows obvious transition from non-commercial energy to commercial energy. ► CO 2 emissions from rural residential energy consumption have significant increases. ► Major driving forces are income of rural farmers and rural energy policies. ► Generate electricity using renewable technology and replace coal with modern biomass.

  14. Fuel coolant interaction experiment by direct electrical heating method

    International Nuclear Information System (INIS)

    Takeda, Tsuneo; Hirano, Kenmei

    1979-01-01

    In the PCM (Power Cooling Mismatch) experiments, the FCI (Fuel Coolant Interaction) test is one of necessary tests in order to predict various phenomena that occur during PCM in the core. A direct electrical heating method is used for the FCI tests for fuel pellet temperature of over 1000 0 C. Therefore, preheating is required before initiating the direct electrical heating. The fuel pin used in the FCI tests is typical LWR fuel element, which is surrounded by coolant water. It is undersirable to heat up the coolant water during preheating of the fuel pin. Therefore, a zirconia (ZrO 2 ) pellet which is similar to a UO 2 pellet in physical and chemical properties is used. Electric property (electric conductivity) of ZrO 2 is particularly suitable for direct electrical heating as in the case of UO 2 . In this experiment, ZrO 2 pellet (melting point 2500 0 C) melting was achieved by use of both preheating and direct electrical heating. Temperature changes of coolant and fuel surface, as well as the pressure change of coolant water, were measured. The molten fuel interacted with the coolant and generated shock waves. A portion of this molten fuel fragmented into small particles during this interaction. The peak pressure of the observed shock wave was about 35 bars. The damaged fuel pin was photographed after disassembly. This report shows the measured coolant pressure changes and the coolant temperature changes, as well as photographs of damaged fuel pin and fuel fragments. (author)

  15. Electricity rates in Canada, 1991

    International Nuclear Information System (INIS)

    1991-01-01

    Numerical data only are presented for monthly electricity costs (residential and commercial) for selected Canadian cities. Total electricity supply is broken down by province. Residential, urban and rural electricity costs, including taxation, are provided for selected Canadian cities. Calculations of electricity costs for commercial and residential sectors are tabulated by province. Historical data from 1974 are supplied

  16. 76 FR 37407 - Energy Conservation Program: Energy Conservation Standards for Residential Furnaces and...

    Science.gov (United States)

    2011-06-27

    .... Background 1. Current Standards a. Furnaces b. Central Air Conditioners and Heat Pumps 2. History of... Compliance Requirements a. Central Air Conditioning and Heat Pumps b. Residential Furnaces 3. Duplication... residential central air conditioners and central air conditioning heat pumps (air conditioners and heat pumps...

  17. Incidental electric heating of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Sonninskii, A V; Sirotin, A M; Vasiliev, Y N

    1981-04-01

    VNIIgaz has improved the conventional Japanese SECT pipeline-heating system, which uses a small steel tube that contains an insulated heater/conductor and is welded to the top of the pipeline. The improved version has two insulated electric heaters - one on the top and the other on the bottom of the pipeline - located inside steel angle irons that are welded to the pipeline. A comparison of experimental results from heating a 200-ft pipeline with both systems at currents of up to 470 A clearly demonstrated the better heating efficiency of the VNIIgaz unit. The improved SECT system would be suitable for various types of pipelines, including gas lines, in the USSR's far north regions.

  18. Stripping demolition of reinforced concrete by electric heating method

    International Nuclear Information System (INIS)

    Nakagawa, Wahei; Nishita, Kiwamu; Kasai, Yoshio

    1993-01-01

    The present paper describes the procedures and results of a series of experiments the authors conducted to verify the efficiency of the electric heating method, previously proposed for so-called stripping demolition by applying electric current through reinforcing bars. In this method, a low voltage high current is run from one end to the other of a reinforcing bar or bars existing in a concrete structure, inducing intense heat in the bar(s) which in its turn brings about cracks in the surrounding concrete mass, facilitating secondary demolition by hammer picks or other means. The experiments were performed on full-scale biological shield wall mock-ups of a BWR and a small reactor. The results of the experiments are summarized as follows. (1) When electric current is applied through reinforcing bars, the bond between concrete and bars is loosened, and cracks start from one bar and progress toward other bars. Under appropriate conditions, the cracks in concrete run from the contact surface at one bar all the way to its the contact surface on another bar. (2) Cracks appear and grow only between two electrodes between which current is applied, not extending out of the area thus defined. (3) The concrete in the region closer to a current-bearing bar is intensely heated, whereas the concrete far from the bars remains nearly unheated. (4) Concrete walls after electric heating of bars disintegrates, if demolished with hammers, with the covering concrete are removed from the remaining portion of the structure together with heated bars, in shapes of flakes. (5) The reinforced concrete collapses in massive pieces of concrete, without generating much dust as is the case with the demolition of a concrete structure not heated by electricity. Results of the experiments show that the electric heating method is worth applying also to the demolition of nuclear power plants where concrete in the radioactivated surface region of shield walls needs to be stripped off in flakes

  19. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    This study is part of a research project concerning the possibilities of applying efficient air cleaning technologies using rotary heat exchanger in residential buildings. The purpose of this project was to identify and adapt new air-cleaning technologies for implementation in HVAC systems...... with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measurements included testing of the filters, separately and combined, in a ductwork to study the efficiency...

  20. Report on an investigation into heat pumps in China in fiscal 1995; 1995 nendo Chugoku ni okeru heat pump system ni kansuru chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The paper surveyed the present status, the status of spread, and the technical development of the technology of heat pumps for residential and industrial uses in China. Main examples of installation of heat pumps are cited below: steam drive absorption type refrigerators in Beijing; sea water heat source turbo heat pumps in Qingdao; hot water drive absorption type refrigerators in Beijing; oil-fueled absorption type water cooling and heating appliances in Beijing; ice latent heat storage airconditioning systems using electrically-driven screw chiller in Beijing; temperature rising systems using electrically-driven heat pump of the solar energy utilization warm water swimming pool in Guangdong Province; cooling water supply using waste heat utilization absorption type refrigerator of the alcohol plant in Shandong Province; timber drying systems using electrically-driven heat pump, and marine product cultivation systems in Quangdong Province; distillation systems using steam turbine heat pump in Jiangxi Province. The demand for heat pumps is expected to be 20 million units under the 9th 5-year plan, and the development of equipment is thought to go toward promotion of energy conservation, low noise, multi-type or multi-functional air conditioning equipment, and computer use. 137 figs., 40 tabs.

  1. The consumptive water footprint of electricity and heat: a global assessment

    NARCIS (Netherlands)

    Mekonnen, Mesfin; Gerbens-Leenes, Winnie; Hoekstra, Arjen Ysbert

    2015-01-01

    Water is essential for electricity and heat production. This study assesses the consumptive water footprint (WF) of electricity and heat generation per world region in the three main stages of the production chain, i.e. fuel supply, construction and operation. We consider electricity from power

  2. Estimating the energy and exergy utilization efficiencies for the residential-commercial sector: an application

    International Nuclear Information System (INIS)

    Utlu, Zafer; Hepbasli, Arif

    2006-01-01

    The main objectives in carrying out the present study are twofold, namely to estimate the energy and exergy utilization efficiencies for the residential-commercial sector and to compare those of various countries with each other. In this regard, Turkey is given as an illustrative example with its latest figures in 2002 since the data related to the following years are still being processed. Total energy and exergy inputs in this year are calculated to be 3257.20 and 3212.42 PJ, respectively. Annual fuel consumptions in space heating, water heating and cooking activities as well as electrical energy uses by appliances are also determined. The energy and exergy utilization efficiency values for the Turkish residential-commercial sector are obtained to be 55.58% and 9.33%, respectively. Besides this, Turkey's overall energy and exergy utilization efficiencies are found to be 46.02% and 24.99%, respectively. The present study clearly indicates the necessity of the planned studies toward increasing exergy utilization efficiencies in the sector studied

  3. The Effect of Electric Load Profiles on the Performance of Off-Grid Residential Hybrid Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Stephen Treado

    2015-10-01

    Full Text Available This paper investigates the energy performance of off-grid residential hybrid renewable electric power systems, particularly the effect of electric load profiles on the ability to harvest available solar energy and avoid the consumption of auxiliary energy in the form of propane. The concepts are illustrated by an analysis of the energy performance of electric and propane-fired refrigerators. Off-grid electric power systems frequently incorporate a renewable source, such as wind or solar photovoltaic (PV, with a back-up power provided by a propane fueled motor/generator. Among other design decisions, residential consumers face the choice of employing an electric refrigerator with a conventional vapor compression refrigeration system, or a fuel-fired refrigerator operating as an absorption refrigeration system. One interesting question is whether it is more advantageous from an energy perspective to use electricity to run the refrigerator, which might be provided by some combination of the PV and propane motor/generator, thereby taking advantage of the relatively higher electric refrigerator Coefficient of Performance (COP and free solar energy but having to accept a low electrical conversion efficiency of the motor/generator, or use thermal energy from the combustion of propane to produce the refrigeration effect via an absorption system, albeit with a much lower COP. The analysis is complicated by the fact that most off-grid renewable electrical power systems utilize a battery bank to provide electrical power when it is not available from the wind turbine or PV system, so the state of charge of the battery bank will have a noticeable impact on what energy source is available at any moment in time. Daily electric load profiles combined with variable solar energy input determine the state of charge of the battery bank, with the degree of synchronization between the two being a critical factor in determining performance. The annual energy usage

  4. An experimental study on the thermal characteristics and heating effect of arc-fault from Cu core in residential electrical wiring fires.

    Science.gov (United States)

    Du, Jian-Hua; Tu, Ran; Zeng, Yi; Pan, Leng; Zhang, Ren-Cheng

    2017-01-01

    The characteristics of a series direct current (DC) arc-fault including both electrical and thermal parameters were investigated based on an arc-fault simulator to provide references for multi-parameter electrical fire detection method. Tests on arc fault behavior with three different initial circuit voltages, resistances and arc gaps were conducted, respectively. The influences of circuit conditions on arc dynamic image, voltage, current or power were interpreted. Also, the temperature rises of electrode surface and ambient air were studied. The results showed that, first, significant variations of arc structure and light emitting were observed under different conditions. A thin outer burning layer of vapor generated from electrodes with orange light was found due to the extremely high arc temperature. Second, with the increasing electrode gap in discharging, the arc power was shown to have a non monotonic relationship with arc length for constant initial circuit voltage and resistance. Finally, the temperature rises of electrode surface caused by heat transfer from arc were found to be not sensitive with increasing arc length due to special heat transfer mechanism. In addition, temperature of ambient air showed a large gradient in radial direction of arc.

  5. An experimental study on the thermal characteristics and heating effect of arc-fault from Cu core in residential electrical wiring fires.

    Directory of Open Access Journals (Sweden)

    Jian-Hua Du

    Full Text Available The characteristics of a series direct current (DC arc-fault including both electrical and thermal parameters were investigated based on an arc-fault simulator to provide references for multi-parameter electrical fire detection method. Tests on arc fault behavior with three different initial circuit voltages, resistances and arc gaps were conducted, respectively. The influences of circuit conditions on arc dynamic image, voltage, current or power were interpreted. Also, the temperature rises of electrode surface and ambient air were studied. The results showed that, first, significant variations of arc structure and light emitting were observed under different conditions. A thin outer burning layer of vapor generated from electrodes with orange light was found due to the extremely high arc temperature. Second, with the increasing electrode gap in discharging, the arc power was shown to have a non monotonic relationship with arc length for constant initial circuit voltage and resistance. Finally, the temperature rises of electrode surface caused by heat transfer from arc were found to be not sensitive with increasing arc length due to special heat transfer mechanism. In addition, temperature of ambient air showed a large gradient in radial direction of arc.

  6. Fundamentals of electroheat electrical technologies for process heating

    CERN Document Server

    Lupi, Sergio

    2017-01-01

    This book provides a comprehensive overview of the main electrical technologies for process heating, which tend to be treated separately in specialized books. Individual chapters focus on heat transfer, electromagnetic fields in electro-technologies, arc furnaces, resistance furnaces, direct resistance heating, induction heating, and high-frequency and microwave heating. The authors highlight those topics of greatest relevance to a wide-ranging teaching program, and at the same time offer a detailed review of the main applications of the various technologies. The content represents a synthesis of the extensive knowledge and experience that the authors have accumulated while researching and teaching at the University of Padua’s Engineering Faculty. This text on industrial electroheating technologies is a valuable resource not only for students of industrial, electrical, chemical, and material science engineering, but also for engineers, technicians and others involved in the application of electroheating and...

  7. Residential Mechanical Precooling

    Energy Technology Data Exchange (ETDEWEB)

    German, Alea [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI); Hoeschele, Marc [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation (ARBI)

    2014-12-01

    Residential air conditioning (AC) represents a challenging load for many electric utilities with poor load factors. Mechanical precooling improves the load factor by shifting cooling operation from on-peak to off-peak hours. This provides benefits to utilities and the electricity grid, as well as to occupants who can take advantage of time-of-use (TOU) electricity rates. Performance benefits stem from reduced compressor cycling, and shifting condensing unit operation to earlier periods of the day when outdoor temperatures are more favorable to operational efficiency. Finding solutions that save energy and reduce demand on the electricity grid is an important national objective and supports key Building America goals. The Alliance for Residential Building Innovation team evaluated mechanical AC precooling strategies in homes throughout the United States. EnergyPlus modeling was used to evaluate two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes. A successful off-peak AC strategy offers the potential for increased efficiency and improved occupant comfort, and promotes a more reliable and robust electricity grid. Demand response capabilities and further integration with photovoltaic TOU generation patterns provide additional opportunities to flatten loads and optimize grid impacts.

  8. A Hybrid dasymetric and machine learning approach to high-resolution residential electricity consumption modeling

    Energy Technology Data Exchange (ETDEWEB)

    Morton, April M [ORNL; Nagle, Nicholas N [ORNL; Piburn, Jesse O [ORNL; Stewart, Robert N [ORNL; McManamay, Ryan A [ORNL

    2017-01-01

    As urban areas continue to grow and evolve in a world of increasing environmental awareness, the need for detailed information regarding residential energy consumption patterns has become increasingly important. Though current modeling efforts mark significant progress in the effort to better understand the spatial distribution of energy consumption, the majority of techniques are highly dependent on region-specific data sources and often require building- or dwelling-level details that are not publicly available for many regions in the United States. Furthermore, many existing methods do not account for errors in input data sources and may not accurately reflect inherent uncertainties in model outputs. We propose an alternative and more general hybrid approach to high-resolution residential electricity consumption modeling by merging a dasymetric model with a complementary machine learning algorithm. The method s flexible data requirement and statistical framework ensure that the model both is applicable to a wide range of regions and considers errors in input data sources.

  9. Micro-CHP systems for residential applications

    International Nuclear Information System (INIS)

    Paepe, Michel de; D'Herdt, Peter; Mertens, David

    2006-01-01

    Micro-CHP systems are now emerging on the market. In this paper, a thorough analysis is made of the operational parameters of 3 types of micro-CHP systems for residential use. Two types of houses (detached and terraced) are compared with a two storey apartment. For each building type, the energy demands for electricity and heat are dynamically determined. Using these load profiles, several CHP systems are designed for each building type. Data were obtained for two commercially available gas engines, two Stirling engines and a fuel cell. Using a dynamic simulation, including start up times, these five system types are compared to the separate energy system of a natural gas boiler and buying electricity from the grid. All CHP systems, if well sized, result in a reduction of primary energy use, though different technologies have very different impacts. Gas engines seem to have the best performance. The economic analysis shows that fuel cells are still too expensive and that even the gas engines only have a small internal rate of return (<5%), and this only occurs in favourable economic circumstances. It can, therefore, be concluded that although the different technologies are technically mature, installation costs should at least be reduced by 50% before CHP systems become interesting for residential use. Condensing gas boilers, now very popular in new homes, prove to be economically more interesting and also have a modest effect on primary energy consumption

  10. Iron aluminide useful as electrical resistance heating elements

    Science.gov (United States)

    Sikka, V.K.; Deevi, S.C.; Fleischhauer, G.S.; Hajaligol, M.R.; Lilly, A.C. Jr.

    1997-04-15

    The invention relates generally to aluminum containing iron-base alloys useful as electrical resistance heating elements. The aluminum containing iron-base alloys have improved room temperature ductility, electrical resistivity, cyclic fatigue resistance, high temperature oxidation resistance, low and high temperature strength, and/or resistance to high temperature sagging. The alloy has an entirely ferritic microstructure which is free of austenite and includes, in weight %, over 4% Al, {=}0.05% Zr or ZrO{sub 2} stringers extending perpendicular to an exposed surface of the heating element or {>=}0.1% oxide dispersoid particles. The alloy can contain 14-32% Al, {<=}2% Ti, {<=}2% Mo, {<=}1% Zr, {<=}1% C, {<=}0.1% B, {<=}30% oxide dispersoid and/or electrically insulating or electrically conductive covalent ceramic particles, {<=}1% rare earth metal, {<=}1% oxygen, {<=}3% Cu, balance Fe. 64 figs.

  11. Residential Cold Climate Heat Pump (CCHP) w/Variable Speed Technology

    Energy Technology Data Exchange (ETDEWEB)

    Messmer, Craig S. [Unico, Inc., Arnold, MO (United States)

    2016-09-30

    This report summarizes the results of a three year program awarded to Unico, Inc. to commercialize a residential cold climate heat pump. Several designs were investigated. Compressors were selected using analysis from Oakridge National Laboratories followed by prototype construction and lab testing in a specially built environmental chamber capable of reaching -30°F. The initial design utilized two variable speed compressors in series with very good capacity results and acceptable efficiency at very cold temperatures. The design was then modified to reduce cost and complexity by redesigning the system using three dual-stage compressors: two in parallel followed by one in series. Extensive testing found significant challenge with oil management, reliability, weight and cost which prevented the system from being fully commercialized. Further analysis of other conceptual designs indicated that these challenges could be overcome in the future.

  12. Field Measurement and Evaluation of the Passive and Active Solar Heating Systems for Residential Building Based on the Qinghai-Tibetan Plateau Case

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2017-10-01

    Full Text Available Passive and active solar heating systems have drawn much attention and are widely used in residence buildings in the Qinghai-Tibetan plateau due to its high radiation intensity. In fact, there is still lack of quantitative evaluation of the passive and active heating effect, especially for residential building in the Qinghai-Tibetan plateau areas. In this study, three kinds of heating strategies, including reference condition, passive solar heating condition and active solar heating condition, were tested in one demonstration residential building. The hourly air temperatures of each room under different conditions were obtained and analyzed. The results show the indoor air temperature in the living room and bedrooms (core zones was much higher than that of other rooms under both passive and active solar heating conditions. In addition, the heating effect with different strategies for core zones of the building was evaluated by the ratio of indoor and outdoor degree hour, which indicates that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment. The passive solar heating could undertake 49.8% degree hours for heating under an evaluation criterion of 14 °C and the active solar heating could undertake 75% degree hours for heating under evaluation criterion of 18 °C, which indicated that solar heating could effectively reduce the traditional energy consumption and improve the indoor thermal environment in this area. These findings could provide reference for the design and application of solar heating in similar climate areas.

  13. Potential for increased wind-generated electricity utilization using heat pumps in urban areas

    International Nuclear Information System (INIS)

    Waite, Michael; Modi, Vijay

    2014-01-01

    Highlights: • Large-scale wind power and increased electric heat pumps were evaluated. • A deterministic model of wind power and electricity demand was developed. • Sub-models for space heating and domestic hot water demand were developed. • Increased use of heat pumps can improve the viability of large-scale wind power. • Larger wind power capacity can meet a target utilization rate with more heat pumps. - Abstract: The U.S. has substantial wind power potential, but given wind’s intermittent availability and misalignment with electricity demand profiles, large-scale deployment of wind turbines could result in high electricity costs due to energy storage requirements or low utilization rates. While fuel switching and heat pumps have been proposed as greenhouse gas (GHG) emissions and energy reduction strategies at the building scale, this paper shows that heat pump adoption could have additional system-wide benefits by increasing the utilization of wind-generated electricity. A model was developed to evaluate the effects of coupling large-scale wind power installations in New York State with increased use of electric heat pumps to meet a portion of space heating and domestic hot water (DHW) demands in New York City. The analysis showed significant increases in wind-generated electricity utilization with increased use of heat pumps, allowing for higher installed capacity of wind power. One scenario indicates that 78.5% annual wind-generated electricity utilization can be achieved with 3 GW of installed wind power capacity generated electricity equal to 20% of existing NYC annual electricity demand; if 20% of space heating and DHW demands are provided by heat pumps, the 78.5% utilization rate can be achieved with an increase of total wind power capacity to 5 GW. Therefore, this integrated supply–demand approach could provide additional system-wide emissions reductions

  14. Renewable energy production support schemes for residential-scale solar photovoltaic systems in Nordic conditions

    International Nuclear Information System (INIS)

    Hirvonen, Janne; Kayo, Genku; Cao, Sunliang; Hasan, Ala; Sirén, Kai

    2015-01-01

    The objective of this study was to examine the effect of production-based support schemes on the economic feasibility of residential-scale PV systems (1–10 kW) in Finland. This was done by calculating the payback time for various sizes of newly installed PV systems for a Finnish detached house with district heating. Three types of economic support schemes (guaranteed selling price, fixed premiums and self-consumption incentives) were tested in an hourly simulation. The load of the building was based on real-life measurements, while PV output was simulated with TRNSYS software. The energy results were post-processed with economic data in MATLAB to find the payback time. Hourly electricity prices from the Nordic energy market were used with PV system prices from Finnish companies. Unsubsidised residential PV systems in Finland had payback times of more than 40 years. The production-based support for PV generation needs to be two to three times the buying price of electricity, to make it possible to pay back the initial investment in 20 years. Low capacity systems with more than 50% self-consumption (under 3 kW) were favoured by self-consumption incentives, while high capacity systems with less than 40% self-consumption (over 5 kW) were favoured by the FIT-type support schemes. - Highlights: • Unsubsidised residential PV is uneconomical in Finland. • Support rate must be 2 times the electricity price for reasonable payback time. • Even using all electricity on-site is not profitable enough without support. • Assumed real interest rate had great influence on payback time. • Hourly electricity prices are much lower than average values from Finnish statistics

  15. Accelerating residential PV expansion: demand analysis for competitive electricity markets

    International Nuclear Information System (INIS)

    Duke, Richard; Williams, Robert; Payne, Adam

    2005-01-01

    This article quantifies the potential market for grid-connected, residential photovoltaic (PV) electricity integrated into new homes built in the US. It complements an earlier supply-side analysis by the authors that demonstrates the potential to reduce PV module prices below $1.5/W p by scaling up existing thin-film technology in 100 MW p /yr manufacturing facilities. The present article demonstrates that, at that price, PV modules may be cost effective in 125,000 new home installations per year (0.5 GW p /yr). While this market is large enough to support multiple scaled up thin-film PV factories, inefficient energy pricing and demand-side market failures will inhibit prospective PV consumers without strong public policy support. Net metering rules, already implemented in many states to encourage PV market launch, represent a crude but reasonable surrogate for efficient electricity pricing mechanisms that may ultimately emerge to internalize the externality benefits of PV. These public benefits include reduced air pollution damages (estimated costs of damage to human health from fossil fuel power plants are presented in Appendix A), deferral of transmission and distribution capital expenditures, reduced exposure to fossil fuel price risks, and increased electricity system reliability for end users. Thus, net metering for PV ought to be implemented as broadly as possible and sustained until efficient pricing is in place. Complementary PV 'buydowns' (e.g., a renewable portfolio standard with a specific PV requirement) are needed to jumpstart regional PV markets

  16. Consumer responses to time varying prices for electricity

    International Nuclear Information System (INIS)

    Thorsnes, Paul; Williams, John; Lawson, Rob

    2012-01-01

    We report new experimental evidence of the household response to weekday differentials in peak and off-peak electricity prices. The data come from Auckland, New Zealand, where peak residential electricity consumption occurs in winter for heating. Peak/off-peak price differentials ranged over four randomly selected groups from 1.0 to 3.5. On average, there was no response except in winter. In winter, participant households reduced electricity consumption by at least 10%, took advantage of lower off-peak prices but did not respond to the peak price differentials. Response varied with house and household size, time spent away from home, and whether water was heated with electricity. - Highlights: ► Seasonal effects in winter. ► High conservation effect from information. ► Higher peak prices no effect on peak use. ► Low off-peak prices encourage less conservation off-peak.

  17. Miscellaneous electricity use in U.S. homes

    International Nuclear Information System (INIS)

    Sanchez, Marla C.; Koomey, Jonathan G.; Moezzi, Mithra M.; Meier, Alan; Huber, Wolfgang

    1999-01-01

    Historically, residential energy and carbon saving efforts have targeted conventional end uses such as water heating, lighting and refrigeration. The emergence of new household appliances has transformed energy use from a few large and easily identifiable end uses into a broad array of ''miscellaneous'' energy services. This group of so called miscellaneous appliances has been a major contributor to growth in electricity demand in the past two decades. We use industry shipment data, lifetimes, and wattage and usage estimates of over 90 individual products to construct a bottom-up end use model (1976-2010). The model is then used to analyze historical and forecasted growth trends, and to identify the largest individual products within the miscellaneous end use. We also use the end use model to identify and analyze policy priorities. Our forecast projects that over the period 1996 to 2010, miscellaneous consumption will increase 115 TWh, accounting for over 90 percent of future residential electricity growth. A large portion of this growth will be due to halogen torchiere lamps and consumer electronics, making these two components of miscellaneous electricity a particularly fertile area for efficiency programs. Approximately 20 percent (40 TWh) of residential miscellaneous electricity is ''leaking electricity'' or energy consumed by appliances when they are not performing their principal function. If the standby power of all appliances with a standby mode is reduced to one watt, the potential energy savings equal 21 TWh/yr, saving roughly$1-2 billion annually

  18. Demonstration of Hydrogen Energy Network and Fuel Cells in Residential Homes

    International Nuclear Information System (INIS)

    Hirohisa Aki; Tetsuhiko Maeda; Itaru Tamura; Akeshi Kegasa; Yoshiro Ishikawa; Ichiro Sugimoto; Itaru Ishii

    2006-01-01

    The authors proposed the setting up of an energy interchange system by establishing energy networks of electricity, hot water, and hydrogen in residential homes. In such networks, some homes are equipped with fuel cell stacks, fuel processors, hydrogen storage devices, and large storage tanks for hot water. The energy network enables the flexible operation of the fuel cell stacks and fuel processors. A demonstration project has been planned in existing residential homes to evaluate the proposal. The demonstration will be presented in a small apartment building. The building will be renovated and will be equipped with a hydrogen production facility, a hydrogen interchange pipe, and fuel cell stacks with a heat recovery device. The energy flow process from hydrogen production to consumption in the homes will be demonstrated. This paper presents the proposed energy interchange system and demonstration project. (authors)

  19. Integrating wind power using intelligent electric water heating

    International Nuclear Information System (INIS)

    Fitzgerald, Niall; Foley, Aoife M.; McKeogh, Eamon

    2012-01-01

    Dwindling fossil fuel resources and pressures to reduce greenhouse gas emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is to instantaneously meet demand, to operate to standards and reduce greenhouse gas emissions. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating has been studied previously, particularly at the domestic level to provide load control, peak shave and to benefit end-users financially with lower bills, particularly in vertically integrated monopolies. In this paper a number of continuous direct load control demand response based electric water heating algorithms are modelled to test the effectiveness of wholesale electricity market signals to study the system benefits. The results are compared and contrasted to determine which control algorithm showed the best potential for energy savings, system marginal price savings and wind integration.

  20. Solving hyperbolic heat conduction using electrical simulation

    International Nuclear Information System (INIS)

    Gheitaghy, A. M.; Talaee, M. R.

    2013-01-01

    In the present study, the electrical network simulation method is proposed to solve the hyperbolic and parabolic heat conduction problem considering Cattaneo-Vernoute (C.V) constitutive relation. Using this new proposed numerical model and the electrical circuit simulation program HSPICE, transient temperature and heat flux profiles at slab can be obtained easily and quickly. To verify the proposed method, the obtained numerical results for cases of one dimensional two-layer slab under periodic boundary temperature with perfect and imperfect thermal contact are compared with the published results. Comparisons show the proposed technique might be considered as a useful tool in the analysis of parabolic and hyperbolic thermal problems.

  1. Meeting the Electrical Energy Needs of a Residential Building with a Wind-Photovoltaic Hybrid System

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Mohammadnezami

    2015-03-01

    Full Text Available A complete hybrid system including a photovoltaic cell, a wind turbine, and battery is modeled to determine the best approach for sizing the system to meet the electrical energy needs of a residential building. In evaluating system performance, the city of Tehran is used as a case study. Matlab software is used for analyzing the data and optimizing the system for the given application. Further, the cost of the system design is investigated, and shows that the electrical cost of the hybrid system in Tehran is 0.62 US$/kWh, which is 78% less expensive than a wind turbine system and 34% less expensive than a photovoltaic system.

  2. Comfort air temperature influence on heating and cooling loads of a residential building

    Science.gov (United States)

    Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.

    2016-08-01

    The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.

  3. Thermalhydraulic behavior of electrically heated rods during critical heat flux transients

    International Nuclear Information System (INIS)

    Lima, Rita de Cassia Fernandes de

    1997-01-01

    In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed utilizing heated rods to simulate operational and accidental conditions of nuclear fuel rods, with special attention to the phenomenon of boiling crisis. The use of mechanisms which detect the abrupt temperature rise allows the electric power switch off. These facts prevent the test section from damage. During the critical heat flux phenomenon the axial heat conduction becomes very important. The study of the dryout and rewetting fronts yields the analysis, planning and following of critical heat flux experiments. These facts are important during the reflooding of nuclear cores at severe accidents. In the present work it is performed a theoretical analysis of the drying and rewetting front propagation during a critical heat flux experiment, starting with the application of an electrical power step or power slope from steady state condition. After the occurrence of critical heat flux, it is predicted the drying front propagation. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. In all these transients the coolant pressure is 13,5 MPa. For one of them, comparisons are done with a pressure of 8,00 MPa. Mass flow and enthalpy influences on the fronts velocities are also analysed. These results show that mass flow has more importance on the drying front velocities whereas the pressure alters strongly the rewetting ones. (author)

  4. Experimental investigation on thermal management of electric vehicle battery with heat pipe

    International Nuclear Information System (INIS)

    Rao Zhonghao; Wang Shuangfeng; Wu Maochun; Lin Zirong; Li Fuhuo

    2013-01-01

    Highlights: ► The thermal management system of electric vehicle battery with heat pipes was designed. ► Temperature rise is a key factor for the design of power battery thermal management system. ► Temperature distribution is inevitable to reference for better design of heat pipes used for heat dissipation. ► Heat pipes are effective for power batteries thermal management within electric vehicles. - Abstract: In order to increase the cycle time of power batteries and decrease the overall cost of electric vehicles, the thermal management system equipped with heat pipes was designed according to the heat generated character of power batteries. The experimental result showed that the maximum temperature could be controlled below 50 °C when the heat generation rate was lower than 50 W. Coupled with the desired temperature difference, the heat generation rate should not exceed 30 W. The maximum temperature and temperature difference are kept within desired rang under unsteady operating conditions and cycle testing conditions. Applying heat pipes based power batteries thermal management is an effective method for energy saving in electric vehicles.

  5. Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Michael Garrabrant; Roger Stout; Paul Glanville; Janice Fitzgerald; Chris Keinath

    2013-01-21

    For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

  6. Electrical heating tapes, their use, energy consumption and energy savings potential

    International Nuclear Information System (INIS)

    Nipkow, J.; Lingenhel, S.

    2002-01-01

    Heating cables require about 0.6% of Swiss electricity consumption, approximately as much as all TV-sets. Most important applications are domestic hot water distribution tubing, frost protection (tubing, gutters) and industrial tubing, each requiring about 1/3. For over 10 years, self-regulating technology is standard for heating cables and offers pre-defined maintenance temperatures. To minimize electricity consumption, in most applications additional control devices (timer, temperature-/ power control) are necessary. The study could not give a general answer to whether domestic hot water distribution systems should be heated by heating cables or circulation systems. The best solution depends on the specific building circumstances. Conclusions of the technical and market analysis say that measures in different fields can transfer the saving potentials into practice: architects and designers of sanitary and electrical installations should be informed by articles in specialized magazines: the goal is either to avoid the use of heating cables or to minimize their electricity consumption, training of plumbers and electricians should treat the efficient use of heating cables. An instruction leaflet is to be created. Building owners and operators should be informed by their specialized magazines about problems with heating cables. (author)

  7. An experimental study of the enhanced heating capacity of an electric heat pump (EHP) using the heat recovered from a gas engine generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Min; Chang, Se Dong [HAC R and D Laboratory, LG Electronics, 327-23 Gasan-Dong, Geumcheon-gu, Seoul 153-802 (Korea); Lee, Jaekeun; Hwang, Yujin [School of Mechanical Engineering, Pusan National University, San 30, Changjeon-Dong, Keumjeong-Ku, Busan 609-735 (Korea)

    2009-11-15

    This paper is concerned with the effect of recovered heat on the heating capacity of an Electric Heat Pump (EHP), which is supplied with electric power and recovered heat from a gas engine generator system. Two methods of supplying recovery heat are examined: (i) to the refrigerant with the discharge line heat exchanger (HEX), and (ii) to the refrigerant of the evaporator with the sub-evaporator. Heating capacity, input power and coefficient of performance (COP) were investigated and compared for each heat recovery method. Conclusively, we found that the second method was most reasonable to recover wasted heat and increased system COP by 215%. (author)

  8. Influence of simulation assumptions and input parameters on energy balance calculations of residential buildings

    International Nuclear Information System (INIS)

    Dodoo, Ambrose; Tettey, Uniben Yao Ayikoe; Gustavsson, Leif

    2017-01-01

    In this study, we modelled the influence of different simulation assumptions on energy balances of two variants of a residential building, comprising the building in its existing state and with energy-efficient improvements. We explored how selected parameter combinations and variations affect the energy balances of the building configurations. The selected parameters encompass outdoor microclimate, building thermal envelope and household electrical equipment including technical installations. Our modelling takes into account hourly as well as seasonal profiles of different internal heat gains. The results suggest that the impact of parameter interactions on calculated space heating of buildings is somewhat small and relatively more noticeable for an energy-efficient building in contrast to a conventional building. We find that the influence of parameters combinations is more apparent as more individual parameters are varied. The simulations show that a building's calculated space heating demand is significantly influenced by how heat gains from electrical equipment are modelled. For the analyzed building versions, calculated final energy for space heating differs by 9–14 kWh/m"2 depending on the assumed energy efficiency level for electrical equipment. The influence of electrical equipment on calculated final space heating is proportionally more significant for an energy-efficient building compared to a conventional building. This study shows the influence of different simulation assumptions and parameter combinations when varied simultaneously. - Highlights: • Energy balances are modelled for conventional and efficient variants of a building. • Influence of assumptions and parameter combinations and variations are explored. • Parameter interactions influence is apparent as more single parameters are varied. • Calculated space heating demand is notably affected by how heat gains are modelled.

  9. Estimating short and long-term residential demand for electricity. New evidence from Sri Lanka

    International Nuclear Information System (INIS)

    Athukorala, P.P.A Wasantha; Wilson, Clevo

    2010-01-01

    This study investigates the short-run dynamics and long-run equilibrium relationship between residential electricity demand and factors influencing demand - per capita income, price of electricity, price of kerosene oil and price of liquefied petroleum gas - using annual data for Sri Lanka for the period, 1960-2007. The study uses unit root, cointegration and error-correction models. The long-run demand elasticities of income, own price and price of kerosene oil (substitute) were estimated to be 0.78, - 0.62, and 0.14 respectively. The short-run elasticities for the same variables were estimated to be 0.32, - 0.16 and 0.10 respectively. Liquefied petroleum (LP) gas is a substitute for electricity only in the short-run with an elasticity of 0.09. The main findings of the paper support the following (1) increasing the price of electricity is not the most effective tool to reduce electricity consumption (2) existing subsidies on electricity consumption can be removed without reducing government revenue (3) the long-run income elasticity of demand shows that any future increase in household incomes is likely to significantly increase the demand for electricity and (4) any power generation plans which consider only current per capita consumption and population growth should be revised taking into account the potential future income increases in order to avoid power shortages in the country. (author)

  10. Estimating short and long-term residential demand for electricity. New evidence from Sri Lanka

    Energy Technology Data Exchange (ETDEWEB)

    Athukorala, P.P.A Wasantha; Wilson, Clevo [School of Economics and Finance, Queensland University of Technology, Brisbane (Australia)

    2010-09-15

    This study investigates the short-run dynamics and long-run equilibrium relationship between residential electricity demand and factors influencing demand - per capita income, price of electricity, price of kerosene oil and price of liquefied petroleum gas - using annual data for Sri Lanka for the period, 1960-2007. The study uses unit root, cointegration and error-correction models. The long-run demand elasticities of income, own price and price of kerosene oil (substitute) were estimated to be 0.78, - 0.62, and 0.14 respectively. The short-run elasticities for the same variables were estimated to be 0.32, - 0.16 and 0.10 respectively. Liquefied petroleum (LP) gas is a substitute for electricity only in the short-run with an elasticity of 0.09. The main findings of the paper support the following (1) increasing the price of electricity is not the most effective tool to reduce electricity consumption (2) existing subsidies on electricity consumption can be removed without reducing government revenue (3) the long-run income elasticity of demand shows that any future increase in household incomes is likely to significantly increase the demand for electricity and (4) any power generation plans which consider only current per capita consumption and population growth should be revised taking into account the potential future income increases in order to avoid power shortages in the country. (author)

  11. Electricity demand profile with high penetration of heat pumps in Nordic area

    DEFF Research Database (Denmark)

    Liu, Zhaoxi; Wu, Qiuwei; Nielsen, Arne Hejde

    2013-01-01

    This paper presents the heat pump (HP) demand profile with high HP penetration in the Nordic area in order to achieve the carbon neutrality power system. The calculation method in the European Standard EN14825 was used to estimate the HP electricity demand profile. The study results show...... there will be high power demand from HPs and the selection of supplemental heating for heat pumps has a big impact on the peak electrical power load of heating. The study in this paper gives an estimate of the scale of the electricity demand with high penetration of heat pumps in the Nordic area....

  12. Emissions from residential combustion considering end-uses and spatial constraints: Part I, methods and spatial distribution

    Science.gov (United States)

    Winijkul, Ekbordin; Fierce, Laura; Bond, Tami C.

    2016-01-01

    This study describes a framework to attribute national-level atmospheric emissions in the year 2010 from the residential sector, one of the largest energy-related sources of aerosol emissions. We place special emphasis on end-uses, dividing usage into cooking, heating, lighting, and others. This study covers regions where solid biomass fuel provides more than 50% of total residential energy: Latin America, Africa, and Asia (5.2 billion people in 2010). Using nightlight data and population density, we classify five land types: urban, electrified rural with forest access, electrified rural without forest access, non-electrified rural with forest access, and non-electrified rural without forest access. We then apportion national-level residential fuel consumption among all land-types and end-uses, and assign end-use technologies to each combination. The resulting calculation gives spatially-distributed emissions of particulate matter, black carbon, organic carbon, nitrogen oxides, methane, non-methane hydrocarbons, carbon monoxide, and carbon dioxide. Within this study region, about 13% of the energy is consumed in urban areas, and 45% in non-urban land near forests. About half the energy is consumed in land without access to electricity. Cooking accounts for 54% of the consumption, heating for 9%, and lighting only 2%, with unidentified uses making up the remainder. Because biofuel use is assumed to occur preferentially where wood is accessible and electricity is not, our method shifts emissions to land types without electrification, compared with previous methods. The framework developed here is an important first step in acknowledging the role of household needs and local constraints in choosing energy provision. Although data and relationships described here need further development, this structure offers a more physically-based understanding of residential energy choices and, ultimately, opportunities for emission reduction.

  13. AGA predicts winter jump in residential gas price

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The American Gas Association predicts the average heating bill for residential gas consumers could increase by as much as 18% this winter. AGA Pres. Mike Baly said, Last year's winter was warmer than normal. If the 1992-93 winter is similar, AGA projects that residential natural gas heating bills will go up about 6%. If we see a return to normal winter weather, our projection show the average bill could rise by almost 18%

  14. Residential greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    1985-02-01

    The following report examines the technical and economic viability of residential greenhouse additions in Whitehorse, Yukon. The greenhouse was constructed using the south facing wall of an existing residence as a common wall. Total construction costs were $18,000, including labour. Annual fuel demand for the residence has been reduced by about 10 per cent for an annual saving of $425. In addition, produce to the value of $1,000 is grown annually in the greenhouse for domestic consumption and commercial resale. Typically the greenhouse operates for nine months each year. There is a net thermal loss during the months of November, December and January as a result of the large area of glazing. As well as supplementing the heating supply solar greenhouses can provide additional cash crops which can be used to offset the cost of construction. Humidity problems are minimal and can be dealt with by exhausting high humidity air. One system which has been considered for the greenhouse is to use a standard residential heat pump to remove excess moisture and to pump heat into the house. This would have a secondary benefit of excluding the need to circulate greenhouse air through the house. Thus any allergenic reactions to the greenhouse air would be prevented. 8 refs., 3 figs, 2 tabs.

  15. The 1986 residential occupant survey

    Energy Technology Data Exchange (ETDEWEB)

    Ivey, D.L.; Alley, P.K.

    1987-04-01

    In 1986, Pacific Northwest Laboratory developed the Residential Occupant Survey-Spring '86, which was implemented. The overall purpose of the study was to collect demographic, attitudinal, and behavioral data related to the use and conservation of electricity in dwellings participating in the Bonneville Power Administration's End-Use Load and Conservation Assessment Program (ELCAP). Information was collected on the respondents' perceptions of the energy efficiency of their dwelling, temperature the dwelling was kept when people were at home and awake during the last heating season, which rooms, if any, were not heated during the last heating season, number of times the dwelling was unoccupied for at least one week, number of times pets were let out of the dwelling per day, attitudes toward energy use and conservation and several socio-demographic variables such as age, sex, and total household income. The results of the data analyses showed age to be an important factor for reported indoor temperature and perceived energy efficiency of the dwelling. The results also showed that almost 60% of the ELCAP occupants do not heat one or more rooms during the heating season, and almost 45% of the ELCAP dwellings were unoccupied for at least one week during the reporting period. In terms of the reported allocation of household income for household energy expenses, the results showed that the reported dollar amount spent for the expenses remained relatively constant over income levels.

  16. Motivational factors influencing the homeowners’ decisions between residential heating systems: An empirical analysis for Germany

    International Nuclear Information System (INIS)

    Michelsen, Carl Christian; Madlener, Reinhard

    2013-01-01

    Heating demand accounts for a large fraction of the overall energy demand of private households in Germany. A better understanding of the adoption and diffusion of energy-efficient and renewables-based residential heating systems (RHS) is of high policy relevance, particularly against the background of climate change, security of energy supply and increasing energy prices. In this paper, we explore the multi-dimensionality of the homeowners’ motivation to decide between competing RHS. A questionnaire survey (N=2440) conducted in 2010 among homeowners who had recently installed a RHS provides the empirical foundation. Principal component analysis shows that 25 items capturing different adoption motivations can be grouped around six dimensions: (1) cost aspects, (2) general attitude towards the RHS, (3) government grant, (4) reactions to external threats (i.e., environmental or energy supply security considerations), (5) comfort considerations, and (6) influence of peers. Moreover, a cluster analysis with the identified motivational factors as segmentation variables reveals three adopter types: (1) the convenience-oriented, (2) the consequences-aware, and (3) the multilaterally-motivated RHS adopter. Finally, we show that the influence of the motivational factors on the adoption decision also differs by certain characteristics of the homeowner and features of the home. - Highlights: ► Study of the multi-dimensionality of the motivation to adopt residential heating systems (RHS). ► Principal component and cluster analysis are applied to representative survey data for Germany. ► Motivation has six dimensions, including rational decision-making and emotional factors. ► Adoption motivation differs by certain characteristics of the homeowner and of the home. ► Many adopters are driven by existing habits and perceptions about the convenience of the RHS

  17. Installation guidelines for Solar Heating System, single-family residence at New Castle, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The Solar Heating System installer guidelines are provided for each subsystem and includes testing and filling the system. This single-family residential heating system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: liquid cooled flat plate collectors; water storage tank; passive solar-fired domestic water preheater; electric hot water heater; heat pump with electric backup; solar hot water coil unit; tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; control system; and air-cooled heat purge unit. Information is also provided on the operating procedures, controls, caution requirements, and routine and schedule maintenance. Information consists of written procedures, schematics, detail drawings, pictures and manufacturer's component data.

  18. Assessing incentive contracts for reducing residential electricity consumption: new experimental methods for new results

    International Nuclear Information System (INIS)

    Frachet, Laure

    2013-01-01

    Facing economic, political and environmental stakes, electricity providers are nowadays developing incentive tools, in order to reduce consumer's demand, particularly during peak demand periods. For residential customers, these tools can be tariffs (dynamic pricing of time-of-use tariffs), or informative devices or services (feedbacks on historical or real-time consumption, given on various media). They might go along with automation systems that can help cutting of some electric devices when needed. In order to evaluate the capacity of these settings among their customers, electricity utilities are developing quite a few studies, which are mainly field experiment often called pilots. During these pilots, demand response tools are implemented on a population sample. These long and expensive studies lid to quantitative and qualitative analysis. We have compiled about 40 of them and extract from this survey some generalizable teachings. We have shown what these results were and highlighted pilot programs' methodological limits. In order to propose a substitute to these heavy experimentations, we assessed the capacity or experimental economics. This relatively new discipline's objective is to evaluation the efficiency of institutions, like markets, but also to study what animate economic agents' behaviour, e.g. preferences, beliefs, cognitive biases, willingness to pay... We were also able to elaborate an experimental protocol dedicated to the evaluation of some demand response contracts' acceptability. The results collected during 14 experimental sessions gave us some innovative clues and insight on these contracts acceptability. But, beyond these results, we have demonstrated that even if experimental economics can't obviously be a substitute for field experiments, it can represent an interesting exploratory methodology. To sum up the experimental economics can take part of residential customers' behaviour understanding, performing

  19. Agent-based model for electricity consumption and storage to evaluate economic viability of tariff arbitrage for residential sector demand response

    International Nuclear Information System (INIS)

    Zheng, Menglian; Meinrenken, Christoph J.; Lackner, Klaus S.

    2014-01-01

    Highlights: • Storage-based demand response (loadshifting) is underutilized in residential sector. • Economics (arbitrage savings versus equipment cost) are not well understood. • Stochastic demand models and real-life tariffs can illuminate economic viability. • A range of available storage options provide economically viable DR. • Daily/seasonal stochastic demand variations crucial to understanding optimum capacity. - Abstract: Demand response (DR) is one of many approaches to address temporal mismatches in demand and supply of grid electricity. More common in the commercial sector, DR usually refers to reducing consumption at certain hours or seasons, thus reducing peak demand from the grid. In the residential sector, where sophisticated appliance-level controls such as automatic dimming of lights or on-demand lowering of air conditioning are less common, building-based electricity storage to shift grid consumption from peak to off-peak times could provide DR without requiring consumers to operate their appliances on shifted or reduced schedules: Storage would be dispatched to appliances as needed while still shaving peaks on the grid. Technologically, storage and two-way-inverters are readily available to enable such residential DR. Economically, however, the situation is less clear. Specifically, are time-varying electricity tariffs available such that electricity cost reduction via arbitrage could offset manufacturing, financing, and installation costs of the required storage? To address this question we (i) devise an agent-based appliance-level stochastic model to simulate the electricity demand of an average U.S. household; (ii) loadshift the demand via simple dispatch strategies; and (iii) determine potential profits to the building owner, i.e. reduced electricity cost of the modified demand with realistic tariffs (Con Edison, NY) minus storage cost. We determine the economic viability for a range of traditional and advanced storage technologies

  20. Electricity savings with pellet stoves and solar heating in electrically heated houses; Elbesparing med pelletkaminer och solvaerme i direktelvaermda smaahus

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Tomas [Hoegskolan Dalarna, Borlaenge (Sweden)

    2004-07-01

    The aim of this study was to investigate how electrically heated houses can be converted to using wood pellet and solar heating. There are a large number of wood pellet stoves on the market. Many stoves have a water jacket, which gives an opportunity to distribute the heat to domestic hot water and a radiator heating system. Three typical Swedish houses with electric resistance heating have been studied. Fourteen different system concepts using wood pellet stoves and solar heating systems have been evaluated. The systems and the houses have been simulated in detail using TRNSYS. The houses have been divided in up to 10 different zones and heat transfer by air circulation through doorways and open doors have been simulated. The pellet stoves were simulated using a recently developed TRNSYS component, which models the start- and stop phases, emissions and the dynamic behaviour of the stoves. The model also calculates the CO-emissions. Simulations were made with one stove without a water jacket and two stoves with different fractions of the generated heat distributed in the water circuit. Simulations show that the electricity savings using a pellet stove are greatly affected by the house plan, the system choice, if the internal doors are open or closed and the desired level of comfort. Installing a stove with a water-jacket connected to a radiator system and a hot water storage has the advantage that heat can be transferred to domestic hot water and be distributed to other rooms. Such systems lead to greater electricity savings, especially in houses having a traditional layout. It was found that not all rooms needed radiators and that it was more effective in most cases to use a stove with a higher fraction of the heat distributed by the water circuit. The economic investigation shows that installing a wood pellet stove without a water jacket gives the lowest total energy- and capital costs in the house with an open plan (for today's energy prices and the

  1. Economic valuation of heat pumps and electric boilers in the Danish energy system

    International Nuclear Information System (INIS)

    Nielsen, Maria Grønnegaard; Morales, Juan Miguel; Zugno, Marco; Pedersen, Thomas Engberg; Madsen, Henrik

    2016-01-01

    Highlights: • We assess the economic value of heat pumps and electric boilers in Denmark. • The daily operation of a heat and power system is modeled by stochastic programming. • Deterministic models overestimate the value of heat pumps and electric boilers. • Heat pumps and electric boilers can reduce the cost of operating the Danish system. • Falling power prices may boost the future value of heat pumps and electric boilers. - Abstract: Heat pumps (HP) and electric immersion boilers (EB) have great potential to increase flexibility in energy systems. In parallel, decreasing taxes on electricity-based heat production are creating a more favorable economic environment for the deployment of these units in Denmark. In this paper, the economic value of heat pumps and electric boilers is assessed by simulating their day-to-day market performance using a novel operational strategy based on two-stage stochastic programming. This stochastic model is employed to optimize jointly the daily operation of HPs and EBs along with the Combined Heat and Power (CHP) units in the system. Uncertainty in the heat demand and power price is modeled via scenarios representing different plausible paths for their future evolution. A series of case-studies are performed using real-world data for the heat and power systems in the Copenhagen area during four representative weeks of 2013. We show that the use of stochastic operational models is critical, as standard deterministic models provide an overestimation of the added benefits from the installation of HPs and EBs, thus leading to over-investment in capacity. Furthermore, we perform sensitivity studies to investigate the effect on market performance of varying capacity and efficiency for these units, as well as of different levels of prices in the electricity market. We find that these parameters substantially affect the profitability of heat pumps and electric boilers, hence, they must be carefully assessed by potential

  2. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    Science.gov (United States)

    Darghouth, Naim Richard

    Net metering has become a widespread policy mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), allowing customers with PV systems to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption. Although net metering is one of the principal drivers for the residential PV market in the U.S., the academic literature on this policy has been sparse and this dissertation contributes to this emerging body of literature. This dissertation explores the linkages between the availability of net metering, wholesale electricity market conditions, retail rates, and the residential bill savings from behind-the-meter PV systems. First, I examine the value of the bill savings that customers receive under net metering and alternatives to net metering, and the associated role of retail rate design, based on current rates and a sample of approximately two hundred residential customers of California's two largest electric utilities. I find that the bill savings per kWh of PV electricity generated varies greatly, largely attributable to the increasing block structure of the California utilities' residential retail rates. I also find that net metering provides significantly greater bill savings than alternative compensation mechanisms based on avoided costs. However, retail electricity rates may shift as wholesale electricity market conditions change. I then investigate a potential change in market conditions -- increased solar PV penetrations -- on wholesale prices in the short-term based on the merit-order effect. This demonstrates the potential price effects of changes in market conditions, but also points to a number of methodological shortcomings of this method, motivating my usage of a long-term capacity investment and economic dispatch model to examine wholesale price effects of various wholesale market scenarios in the subsequent analysis. By developing

  3. 77 FR 74559 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Science.gov (United States)

    2012-12-17

    ... Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating... Energy (DOE) is amending its test procedures for residential water heaters, direct heating equipment (DHE... necessary for residential water heaters, because the existing test procedures for those products already...

  4. 76 FR 56347 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters...

    Science.gov (United States)

    2011-09-13

    ... Conservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating... proposed to amend, where appropriate, its test procedures for residential water heaters, direct heating... notes that the test procedure and metric for residential water heaters currently address and incorporate...

  5. Experimental investigation on an integrated thermal management system with heat pipe heat exchanger for electric vehicle

    International Nuclear Information System (INIS)

    Zou, Huiming; Wang, Wei; Zhang, Guiying; Qin, Fei; Tian, Changqing; Yan, Yuying

    2016-01-01

    Highlights: • An integrated thermal management system is proposed for electric vehicle. • The parallel branch of battery chiller can supply additional cooling capacity. • Heat pipe performance on preheating mode is better than that on cooling mode. • Heat pipe heat exchanger is a feasible choice for battery thermal management. - Abstract: An integrated thermal management system combining a heat pipe battery cooling/preheating system with the heat pump air conditioning system is presented to fulfill the comprehensive energy utilization for electric vehicles. A test bench with battery heat pipe heat exchanger and heat pump air conditioning for a regular five-chair electric car is set up to research the performance of this integrated system under different working conditions. The investigation results show that as the system is designed to meet the basic cabinet cooling demand, the additional parallel branch of battery chiller is a good way to solve the battery group cooling problem, which can supply about 20% additional cooling capacity without input power increase. Its coefficient of performance for cabinet heating is around 1.34 at −20 °C out-car temperature and 20 °C in-car temperature. The specific heat of the battery group is tested about 1.24 kJ/kg °C. There exists a necessary temperature condition for the heat pipe heat exchanger to start action. The heat pipe heat transfer performance is around 0.87 W/°C on cooling mode and 1.11 W/°C on preheating mode. The gravity role makes the heat transfer performance of the heat pipe on preheating mode better than that on cooling mode.

  6. Iron aluminide useful as electrical resistance heating elements

    Science.gov (United States)

    Sikka, Vinod K.; Deevi, Seetharama C.; Fleischhauer, Grier S.; Hajaligol, Mohammad R.; Lilly, Jr., A. Clifton

    1997-01-01

    The invention relates generally to aluminum containing iron-base alloys useful as electrical resistance heating elements. The aluminum containing iron-base alloys have improved room temperature ductility, electrical resistivity, cyclic fatigue resistance, high temperature oxidation resistance, low and high temperature strength, and/or resistance to high temperature sagging. The alloy has an entirely ferritic microstructure which is free of austenite and includes, in weight %, over 4% Al, .ltoreq.1% Cr and either .gtoreq.0.05% Zr or ZrO.sub.2 stringers extending perpendicular to an exposed surface of the heating element or .gtoreq.0.1% oxide dispersoid particles. The alloy can contain 14-32% Al, .ltoreq.2% Ti, .ltoreq.2% Mo, .ltoreq.1% Zr, .ltoreq.1% C, .ltoreq.0.1% B, .ltoreq.30% oxide dispersoid and/or electrically insulating or electrically conductive covalent ceramic particles, .ltoreq.1% rare earth metal, .ltoreq.1% oxygen, .ltoreq.3% Cu, balance Fe.

  7. Thermal Performance of Typical Residential Building in Karachi with Different Materials for Construction

    Directory of Open Access Journals (Sweden)

    Nafeesa Shaheen

    2016-04-01

    Full Text Available This research work deals with a study of a residential building located in climatic context of Karachi with the objective of being the study of thermal performance based upon passive design techniques. The study helps in reducing the electricity consumption by improving indoor temperatures. The existing residential buildings in Karachi were studied with reference to their planning and design, analyzed and evaluated. Different construction?s compositions of buildings were identified, surveyed and analyzed in making of the effective building envelops. Autodesk® Ecotect, 2011 was used to determine indoor comfort conditions and HVAC (Heating, Ventilation, Air-Conditioning and Cooling loads. The result of the research depicted significant energy savings of 38.5% in HVAC loads with proposed building envelop of locally available materials and glazing.

  8. The impact of consumer behavior on residential energy demand for space heating

    Energy Technology Data Exchange (ETDEWEB)

    Haas, R.; Auer, H.; Biermayr, P. [Vienna Univ. of Technology (Austria). Inst. of Energy Economics

    1998-04-01

    Besides technical parameters, consumer behavior is the most important issue with respect to energy consumption in households. In this paper, the results of a cross-section analysis of Austrian households are presented. The impact of the following parameters on residential energy demand for space heating have been investigated: (i) thermal quality of buildings; (ii) consumer behavior; (iii) heating degree days; (iv) building type (single- or multi-family dwellings). The result of this investigation provides evidence of a rebound-effect of about 15 to 30% due to building retrofit. This leads to the conclusion that energy savings achieved in practice (and straightforward the reduction in CO{sub 2} emissions) due to energy conservation measures will be lower than those calculated in engineering conservation studies. Straightforward, the most important conclusions for energy policy makers are: (i) Standards, building codes, respectively, are important tools to increase the thermal quality of new buildings; and (ii) Due to prevailing low energy prices, a triggering tool has to be implemented which may be rebates or loans. (orig.)

  9. Setting up charging electric stations within residential communities in current China: Gaming of government agencies and property management companies

    International Nuclear Information System (INIS)

    Wu, Tian; Ma, Lin; Mao, Zhonggen; Ou, Xunmin

    2015-01-01

    The difficulty of charging electric vehicles (EVs) is now hindering their further development. Governments generally choose to build stations for home charging (including piles) within residential communities. Given the conflict of interest between various government agencies and property management companies, constructing a charging station within residential communities would result in welfare loss for the property management companies and therefore lead to the principal–agent problem. This paper constructs a two-period imperfect information game theory model to study the moral hazard involved in this issue and government agencies' optimal choice. In the analytic solution of the model, we find that the optimal choice for a farsighted government agency is to constantly improve the incentive mechanism and introduce charging stations only when the conflict of interest is eliminated. Any benefits derived from government regulations by force would prove short-lived. The government should focus on long-term returns in the development of EVs, and its optimal mechanism should be designed to mitigate the principal–agent problem of property management companies, thereby accelerate the progress of EV charging infrastructure and improve overall social welfare. - Highlights: • The charging of electric vehicles (EVs) is hindering their use. • A game theory model is used for analysis of EV charging station construction. • Charging stations are in residential communities in China. • Government agencies are constantly improving incentive mechanisms

  10. Status of non-electric nuclear heat applications: Technology and safety

    International Nuclear Information System (INIS)

    2000-11-01

    Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the growing experience being accumulated, the IAEA periodically reviews the progress and new developments in the field of nuclear heat applications. This publication summarizes the recent activities among Member States presented at a Technical Committee meeting in April 1999. The purpose of the meeting was to provide a forum for the exchange of up to date information on the prospect, design, safety and licensing aspects, and development of non-electrical applications of nuclear heat for industrial use. This mainly included seawater desalination and hydrogen production

  11. Economic aspects of electricity and industrial heat generating reactors

    International Nuclear Information System (INIS)

    Gaussens, J.; Moulle, N.; Dutheil, F.

    1964-01-01

    The economic advantage of electricity-generating nuclear stations decreases when their size decreases. However, when a counter-pressure turbine is joined on to a reactor and the residual heat can be properly used, it can be shown that fairly low capacity nuclear equipment may compete with conventional equipment under certain realistic enough conditions. The aim of this paper is to define these special conditions under which nuclear energy can be profitable. They are connected with the location and the general economic environment of the station, the pattern of the electricity and heat demands it must meet, the level of fuel and specific capital costs, nuclear and conventional. These conditions entail certain technical and economic specifications for the reactors used in this way otherwise they are unlikely to be competitive. In addition, these results are referred to the potential steam and electricity market, which leads us to examine certain uses for the heat generated by double purpose power stations; for example, to supply combined industrial plants, various types of town heating and for removal of salt from sea water. (authors) [fr

  12. An exploratory analysis of California residential customer response to critical peak pricing of electricity

    International Nuclear Information System (INIS)

    Herter, Karen; McAuliffe, Patrick; Rosenfeld, Arthur

    2007-01-01

    This paper summarizes the results from an exploratory analysis of residential customer response to a critical peak pricing (CPP) experiment in California, in which 15 times per year participating customers received high price signals dispatched by a local electricity distribution company. The high prices were about three times the on-peak price for the otherwise applicable time-of-use rate. Using hourly load data collected during the 15-month experiment, we find statistically significant load reduction for participants both with and without automated end-use control technologies. During 5-h critical peak periods, participants without control technology used up to 13% less energy than they did during normal peak periods. Participants equipped with programmable communicating thermostats used 25% and 41% less for 5 and 2h critical events, respectively. Thus, this paper offers convincing evidence that the residential sector can provide substantial contributions to retail demand response, which is considered a potential tool for mitigating market power, stabilizing wholesale market prices, managing system reliability, and maintaining system resource adequacy. (author)

  13. Modeling temporal variations in global residential energy consumption and pollutant emissions

    International Nuclear Information System (INIS)

    Chen, Han; Huang, Ye; Shen, Huizhong; Chen, Yilin; Ru, Muye; Chen, Yuanchen; Lin, Nan; Su, Shu; Zhuo, Shaojie; Zhong, Qirui; Wang, Xilong; Liu, Junfeng; Li, Bengang; Tao, Shu

    2016-01-01

    Highlights: • Space-for-time substitution was tested for seasonality of residential energy. • Regression models were developed to simulate global residential energy consumption. • Factors affecting the temporal trend in residential energy use were identified. • Climate warming will induce changes in residential energy use and emissions. - Abstract: Energy data are often reported on an annual basis. To address the climate and health impacts of greenhouse gases and air pollutants, seasonally resolved emissions inventories are needed. The seasonality of energy consumption is most affected by consumption in the residential sector. In this study, a set of regression models were developed based on temperature-related variables and a series of socioeconomic parameters to quantify global electricity and fuel consumption for the residential sector. The models were evaluated against observations and applied to simulate monthly changes in residential energy consumption and the resultant emissions of air pollutants. Changes in energy consumption are strongly affected by economic prosperity and population growth. Climate change, electricity prices, and urbanization also affect energy use. Climate warming will cause a net increase in electricity consumption and a decrease in fuel consumption by the residential sector. Consequently, emissions of CO_2, SO_2, and Hg are predicted to decrease, while emissions of incomplete combustion products are expected to increase. These changes vary regionally.

  14. Waste Heat to Power Market Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Elson, Amelia [ICF International, Fairfax, VA (United States); Tidball, Rick [ICF International, Fairfax, VA (United States); Hampson, Anne [ICF International, Fairfax, VA (United States)

    2015-03-01

    Waste heat to power (WHP) is the process of capturing heat discarded by an existing process and using that heat to generate electricity. In the industrial sector, waste heat streams are generated by kilns, furnaces, ovens, turbines, engines, and other equipment. In addition to processes at industrial plants, waste heat streams suitable for WHP are generated at field locations, including landfills, compressor stations, and mining sites. Waste heat streams are also produced in the residential and commercial sectors, but compared to industrial sites these waste heat streams typically have lower temperatures and much lower volumetric flow rates. The economic feasibility for WHP declines as the temperature and flow rate decline, and most WHP technologies are therefore applied in industrial markets where waste heat stream characteristics are more favorable. This report provides an assessment of the potential market for WHP in the industrial sector in the United States.

  15. Thermodynamic investigation of a shared cogeneration system with electrical cars for northern Europe climate

    DEFF Research Database (Denmark)

    Vialetto, Giulio; Noro, Marco; Rokni, Masoud

    2017-01-01

    cells, heat pump and Stirling engine are utilised as a system to achieve high energy conversion efficiency. A transition from traditional petrol cars to electric mobility is also considered and simulated here. Different types of fuel are considered to demonstrate the high versatility of the simulated....... These goals can be achieved increasing renewable energy sources and/or efficiency on energy production processes. In this paper an innovative micro-cogeneration system for household application is presented: it covers heating, domestic hot water and electricity demands for a residential user. Solid oxide fuel...

  16. Influence of electrical and hybrid heating on bread quality during baking

    OpenAIRE

    Chhanwal, N.; Ezhilarasi, P. N.; Indrani, D.; Anandharamakrishnan, C.

    2014-01-01

    Energy efficiency and product quality are the key factors for any food processing industry. The aim of the study was to develop energy and time efficient baking process. The hybrid heating (Infrared + Electrical) oven was designed and fabricated using two infrared lamps and electric heating coils. The developed oven can be operated in serial or combined heating modes. The standardized baking conditions were 18 min at 220°C to produce the bread from hybrid heating oven. Effect of baking with h...

  17. Energy conservation and conversion of electrical heating systems in detached houses

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, Leif; Joelsson, Anna [Ecotechnology, Department of Engineering, Physics and Mathematics, Mid Sweden University, SE-831 25 Oestersund, (Sweden)

    2007-06-15

    In this study, a Swedish house built in 1974, heated with resistance heaters was analysed. Different options for changing the heating system and electricity production were compared for this type of detached house, assuming coal-based electricity production as a reference. Changes in the fuel used, the electricity production technology, the end-use heating technology and the heat demand were analysed. The aim was to show how these different parts of the energy system interact and to evaluate the cost-effectiveness of reducing CO{sub 2} emission and primary energy use by different combinations of changes. The results showed that the CO{sub 2} emission and primary energy use could be reduced by 95 and 70%, respectively, without increased heating costs in a national economic perspective. The choice of end-use heating system had a greater influence than the energy conservation measures on the parameters studied. The energy conservation measures were less cost-effective in combination with the more energy-efficient heating systems, although the fact that they reduced the heat demand, and thus also the investment cost of the new heating system, was taken into account. (Author)

  18. Development of Innovative Heating and Cooling Systems Using Renewable Energy Sources for Non-Residential Buildings

    Directory of Open Access Journals (Sweden)

    Cinzia Buratti

    2013-10-01

    Full Text Available Industrial and commercial areas are synonymous with high energy consumption, both for heating/cooling and electric power requirements, which are in general associated to a massive use of fossil fuels producing consequent greenhouse gas emissions. Two pilot systems, co-funded by the Italian Ministry for the Environment, have been created to upgrade the heating/cooling systems of two existing buildings on the largest industrial estate in Umbria, Italy. The upgrade was specifically designed to improve the system efficiency and to cover the overall energy which needs with renewable energy resources. In both cases a solar photovoltaic plant provides the required electric power. The first system features a geothermal heat pump with an innovative layout: a heat-storage water tank, buried just below ground level, allows a significant reduction of the geothermal unit size, hence requiring fewer and/or shorter boreholes (up to 60%–70%. In the other system a biomass boiler is coupled with an absorption chiller machine, controlling the indoor air temperature in both summer and winter. In this case, lower electricity consumption, if compared to an electric compression chiller, is obtained. The first results of the monitoring of summer cooling are presented and an evaluation of the performance of the two pilot systems is given.

  19. A Cost-Effective Electric Vehicle Charging Method Designed For Residential Homes with Renewable Energy

    Science.gov (United States)

    Lie, T. T.; Liang, Xiuli; Haque, M. H.

    2015-03-01

    Most of the electrical infrastructure in use around the world today is decades old, and may be illsuited to widespread proliferation of personal Electric Vehicles (EVs) whose charging requirements will place increasing strain on grid demand. In order to reduce the pressure on the grid and taking benefits of off peak charging, this paper presents a smart and cost effective EV charging methodology for residential homes equipped with renewable energy resources such as Photovoltaic (PV) panels and battery. The proposed method ensures slower battery degradation and prevents overcharging. The performance of the proposed algorithm is verified by conducting simulation studies utilizing running data of Nissan Altra. From the simulation study results, the algorithm is shown to be effective and feasible which minimizes not only the charging cost but also can shift the charging time from peak value to off-peak time.

  20. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  1. An analysis of a demand charge electricity grid tariff in the residential sector

    International Nuclear Information System (INIS)

    Stokke, A. V.; Doorman, G.L.; Ericson, T.

    2010-01-01

    This paper analyzes the demand response from residential electricity consumers to a demand charge grid tariff. The tariff charges the maximum hourly peak consumption in each of the winter months Dec, Jan, and Feb, thus giving incentives to reduce peak consumption. We use hourly electricity consumption data from 443 households, as well as data on their grid and power prices, the local temperature, wind speed, and hours of daylight. The panel data set is analyzed with a fixed effects regression model. The estimates indicate average demand reductions up to 0.37 kWh/h per household in response to the tariff. This is on average a 5% reduction, with a maximum reduction of 12% in hour 8 in Dec. The consumers did not receive any information on their continuous consumption or any reminders when the tariff was in effect. It is likely that the consumption reductions would have been even higher with more information to the consumers.

  2. Electricity Market Optimization of Heat Pump Portfolio

    DEFF Research Database (Denmark)

    Biegel, Benjamin; Andersen, Palle; Pedersen, Tom S.

    2013-01-01

    We consider a portfolio of domestic heat pumps controlled by an aggregator. The aggregator is able to adjust the consumption of the heat pumps without affecting the comfort in the houses and uses this ability to shift the main consumption to hours with low electricity prices. Further......, the aggregator is able to place upward and downward regulating bids in the regulating power market based on the consumption flexibility. A simulation is carried out based on data from a Danish domestic heat pump project, historical spot prices, regulating power prices, and spot price predictions. The simulations...

  3. Information v. energy efficiency incentives: Evidence from residential electricity consumption in Maryland

    International Nuclear Information System (INIS)

    Alberini, Anna; Towe, Charles

    2015-01-01

    We focus on two utility programs intended to reduce energy usage and the associated CO2 emissions—a home energy audit and rebates on the purchase of high-efficiency air-source heat pumps. We use a unique panel dataset from participating and non-participating households to estimate the average treatment effect of participating in either program on electricity usage. We fit models with household-by-season, season-by-year, and household-by-year fixed effects to account for all possible confounders that might influence energy usage. Since the programs are voluntary, we seek to restore near-exogeneity of the program “treatment” by matching participating households with control households. We deploy coarsened exact matching (CEM; Iacus et al., 2011) as our main matching method. We ask whether it is sufficient to match households based on past electricity usage, or if we gain by adding structural characteristics of the home, including heating system type. We find that the two programs reduce electricity usage by 5% on average. The effects are strong in both winter and summer for the energy audit groups but appear to be stronger in the winter for the heat pump rebate group. Adding house characteristics to the matching variables does seem to affect results, suggesting that using past usage alone, or house characteristics alone, may not be sufficient to identify the effects of program participation.

  4. Profitability Analysis of Residential Wind Turbines with Battery Energy Storage

    Science.gov (United States)

    She, Ying; Erdem, Ergin; Shi, Jing

    Residential wind turbines are often accompanied by an energy storage system for the off-the-grid users, instead of the on-the-grid users, to reduce the risk of black-out. In this paper, we argue that residential wind turbines with battery energy storage could actually be beneficial to the on-the-grid users as well in terms of monetary gain from differential pricing for buying electricity from the grid and the ability to sell electricity back to the grid. We develop a mixed-integer linear programming model to maximize the profit of a residential wind turbine system while meeting the daily household electricity consumption. A case study is designed to investigate the effects of differential pricing schemes and sell-back schemes on the economic output of a 2-kW wind turbine with lithium battery storage. Overall, based on the current settings in California, a residential wind turbine with battery storage carries more economical benefits than the wind turbine alone.

  5. Absorption technology for solar and waste heat utilization

    International Nuclear Information System (INIS)

    Grossman, G.

    1993-01-01

    Absorption heat pumps, first developed in the 19th century, have received renewed and growing attention in the past two decades. With the increasing cost of oil and electricity, the particular features of this heat-powered cycle have made it attractive for both residential and industrial applications. Solar-powered air conditioning, gas-fired domestic cooling and waste-heat-powered temperature boosters are some of the applications on which intensive research and development has been conducted. This paper describes the operation of absorption systems and discusses several practical applications. It surveys recent advances in absorption technology, including the selection of working fluids, cycle improvements and multi-staging, and fundamentals of the combined heat and mass transfer in absorption processes. (author)

  6. Material Research on Salt Hydrates for Seasonal Heat Storage Application in a Residential Environment

    Energy Technology Data Exchange (ETDEWEB)

    Ferchaud, C.J.; Zondag, H.A.; De Boer, R. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2013-09-15

    Water vapor sorption in salt hydrates is a promising method to realize seasonal solar heat storage in the residential sector. Several materials already showed promising performance for this application. However, the stability of these materials needs to be improved for long-term (30 year) application in seasonal solar heat storages. The purpose of this article is to identify the influence of the material properties of the salt hydrates on the performance and the reaction kinetics of the sorption process. The experimental investigation presented in this article shows that the two salt hydrates Li2SO4.H2O and CuSO4.5H2O can store and release heat under the operating conditions of a seasonal solar heat storage in a fully reversible way. However, these two materials show differences in terms of energy density and reaction kinetics. Li2SO4.H2O can release heat with an energy density of around 0.80 GJ/m{sup 3} within 4 hours of rehydration at 25C, while CuSO4.5H2O needs around 130 hours at the same temperature to be fully rehydrated and reaches an energy density of 1.85 GJ/m{sup 3}. Since the two salts are dehydrated and hydrated under the same conditions, this difference in behavior is directly related to the intrinsic properties of the materials.

  7. Comparison of Advanced Residential Water Heating Technologies in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-05-01

    In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

  8. The trigger matters: The decision-making process for heating systems in the residential building sector

    International Nuclear Information System (INIS)

    Hecher, Maria; Hatzl, Stefanie; Knoeri, Christof; Posch, Alfred

    2017-01-01

    As heat demand of buildings accounts for a significant amount of final energy use and related carbon emissions, it’s important to gain insights into the homeowners’ decision-making processes and to identify factors determining the choice of heating systems. In this study, data was collected in an online survey carried out in 2015, from private homeowners of existing and newly built single and double-family houses in Austria who had invested in a new heating system within the last ten years (N=484). In contrast to previous studies, this study specifically investigates the triggers behind homeowner decisions to invest in a new heating system (e.g. problem, opportunity, or new building situation). Results of binary logistic regression analysis show that subsidies for heating system tabinvestments and infrastructural adjustments reveal to be most effective for homeowners in problem situations to foster alternative heating systems. For homeowners in opportunity situations (e.g. building refurbishment), in addition operational convenience appears to be important. For new buildings, the main barriers for alternative heating system adoption were found in the positive perception of fuel supply security and feasibility of fossil systems. Thus, the use of trigger-specific policy measures is proposed to foster alternative heating systems in the residential building sector. - Highlights: • Homeowners’ triggers determine heating system adoption decisions. • It is crucial to reach homeowners early enough to avoid problem situations. • For problem-triggered homeowners, subsidies are most effective. • Opportunity-triggered homeowners prefer alternative heating systems. • Opportunity-triggered homeowners need solid decision basis for technology comparison.

  9. SIZING AND COSTING OPTIMISATION OF A TYPICAL WIND/PV HYBRID ELECTRICITY GENERATION SYSTEM FOR A TYPICAL RESIDENTIAL BUILDING IN URBAN ARMIDALE NSW, AUSTRALIA

    Directory of Open Access Journals (Sweden)

    Yasser Maklad

    2014-04-01

    Full Text Available This study investigates the wind and solar electricity generation availability and potentiality for residential buildings in Armidale NSW, Australia. The main purpose of this study is to design an appropriate wind-PV hybrid system to cover the electricity consumption of typical residential buildings of various occupancy rates and relevant various average electrical daily consumption. In order to do achieve that, monthly average solar irradiance monthly average wind speed historical data observed at weather station belongs to the Australian bureau of meteorology in Armidale town over a fourteen years period from 1997–2010. Simulation of solar photovoltaic panels and wind turbines were conducted to obtain the optimal hybrid system sizing and best efficient with lowest cost. Correlations between the solar and wind power data were carried out on an hourly, daily, and monthly basis. It is shown that the hybrid system can be applied for the efficient and economic utilization of wind and solar renewable energy sources.

  10. Achievements and suggestions of heat metering and energy efficiency retrofit for existing residential buildings in northern heating regions of China

    International Nuclear Information System (INIS)

    Yan Ding; Zhe Tian; Yong Wu; Neng Zhu

    2011-01-01

    In order to promote energy efficiency and emission reduction, the importance of improving building energy efficiency received sufficient attention from Chinese Government. The heat metering and energy efficiency retrofit for existing residential buildings of 0.15 billion m 2 in northern heating regions of China was initiated in 2007 and completed successfully at the end of 2010. This article introduced the background and outline of the retrofit project during the period of 11th five-year plan. Numerous achievements that received by retrofit such as environmental protection effect, improvement of indoor environment, improvement of heating system, investment guidance effect, promotion of relevant industries and increasing chances of employment were concluded. Valuable experience that acquired from the retrofit project during the period of 11th five-year plan was also summarized in this article. By analyzing the main problems emerged in the past, pertinent suggestions were put forward to promote a larger scale and more efficient retrofit project in the period of 12th five-year plan. - Highlights: →Successful implementation of a retrofit project in China is introduced. → Significance of the project contributing to emission reduction is analyzed. →Achievements are summarized and future suggestions are put forward.

  11. Low-Cost Gas Heat Pump for Building Space Heating

    Energy Technology Data Exchange (ETDEWEB)

    Garrabrant, Michael [Stone Mountain Technologies, Inc., Johnson City, TN (United States); Keinath, Christopher [Stone Mountain Technologies, Inc., Johnson City, TN (United States)

    2016-10-11

    Gas-fired residential space heating in the U.S is predominantly supplied by furnaces and boilers. These technologies have been approaching their thermodynamic limit over the past 30 years and improvements for high efficiency units have approached a point of diminishing return. Electric heat pumps are growing in popularity but their heating performance at low ambient temperatures is poor. The development of a low-cost gas absorption heat pump would offer a significant improvement to current furnaces and boilers, and in heating dominated climate zones when compared to electric heat pumps. Gas absorption heat pumps (GAHP) exceed the traditional limit of thermal efficiency encountered by typical furnaces and boilers, and maintain high levels of performance at low ambient temperatures. The project team designed and demonstrated two low-cost packaged prototype GAHP space heating systems during the course of this investigation. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, and the Gas Technology Institute (GTI), the cross-functional team completed research and development tasks including cycle modeling, 8× scaling of a compact solution pump, combustion system development, breadboard evaluation, fabrication of two packaged prototype units, third party testing of the first prototype, and the evaluation of cost and energy savings compared to high and minimum efficiency gas options. Over the course of the project and with the fabrication of two Alpha prototypes it was shown that this technology met or exceeded most of the stated project targets. At ambient temperatures of 47, 35, 17 and -13°F the prototypes achieved gas based coefficients of performance of 1.50, 1.44, 1.37, and 1.17, respectively. Both units operated with parasitic loads well below the 750 watt target with the second Alpha prototype operating 75-100 watts below the first Alpha prototype. Modulation of the units at 4:1 was achieved with the project goal of 2:1 modulation

  12. Technical assessment of electric heat boosters in low-temperature district heating based on combined heat and power analysis

    DEFF Research Database (Denmark)

    Cai, Hanmin; You, Shi; Wang, Jiawei

    2018-01-01

    This paper provides a technical assessment of electric heat boosters (EHBs) in low-energy districts. The analysis is based on a hypothetical district with 23 terraced single-family houses supplied by both a lowtemperature district heating (LTDH) network and a low-voltage network (LVN). Two case...

  13. Research highlights : study of the noise generated by heat pumps in residential areas

    International Nuclear Information System (INIS)

    Rousseau, J.

    2000-01-01

    Rising energy costs and aggressive marketing played a major role in the substantial increase in the number of domestic heat pumps installed. As a rule, heat pumps are connected to the heating and ventilation systems on the outside of the house. Whether the heat pump is equipped with an integrated compressor or not, it creates noise. The noise is generated by the powerful fan designed to cool all the coils, and also by the compressor itself and the circulation of the refrigerant gas. Some municipalities received so many complaints on this topic that they are considering adopting noise bylaws. The first objective of the research undertaken by Canada Mortgage and Housing Corporation on heat pumps in residential areas was to analyze the noise pollution mode of commonly used heat pumps. A study of a simple noise reduction device was performed, and the extent to which it should be used. Finally, there had to be no reduction of the thermal capacities of the pumps. Phase 1 of the study took place between May and August 1990, in the area of Quebec City. A total of 125 heat pumps were identified. The four major manufacturers were Trane, Carrier, York, and Lennox. Initial sound pressure levels measurements were made at one metre from the unit, for 80 such units, respecting the ratio by brands in the sample of 125. A detailed global noise measurement determined the sound power of each pump. A detailed muffler feasibility study was then conducted, using a Trane heat pump. The results of the study indicated that heat pumps were a major source of continuous noise in low and mid-density areas. It was discovered that a noise attenuation device could always be built around heat pumps, which needed to be installed as close as possible to the casing of the heat pump. It is not possible to design a device to fit each and every heat pump, the design is specific to the dimensions and characteristics of each model of heat pump. The thermal performance of the pumps will not be affected by

  14. Incentive mechanism design for the residential building energy efficiency improvement of heating zones in North China

    International Nuclear Information System (INIS)

    Zhong, Y.; Cai, W.G.; Wu, Y.; Ren, H.

    2009-01-01

    Starting with analyzing the investigation results by Ministry of Housing and Urban-Rural Development of China in 2005, more than half of the 10,236 participants are willing to improve the residential building energy efficiency and accept an additional cost of less than 10% of the total cost, the authors illustrate that incenting actions are necessary to improve building energy efficiency and build a central government-local government-market model. As a result of the model analysis, to pursue good execution effects brought by the incentive policies, the executors are required to distinguish the differences of incentive objects' economic activities and strongly respect the incenting on the energy conservation performance. A case study on the incentive policies of existing residential building energy efficiency improvement in heating zones in North China is given as well. Finally, it is strongly recommended to give the first priority to performance-based incentives so that to reduce the lazy behaviors of the incented objects and ensure the targets to be achieved.

  15. Studies in the economics of electricity and heating

    International Nuclear Information System (INIS)

    Andersson, Roland; Bohman, M.; Taylor, L.

    1992-01-01

    This study deals with problems of pricing and capacity planning of electricity and to some extent, heat, as well as with the evaluation of research and development projects. A critical review is given of the discussion in the economic literature concerning whether the price for public utilities should be based on short-run (SRMC) or long-run marginal costs (LRMC). We find it advisable to dispense with the LRMC concept altogether and rely on pricing based on SRMC. We deal with the design of such prices, how they depend on peak and off-peak loads, locational differences in production, transmission and distribution costs etc., particularly when both demand and supply are random. Then follows a critical analysis of the high-voltage as well as low-voltage electricity tariffs used in Sweden. The coordinated pricing system used among power producers in the Nordic countries is found to be an almost ideal application of the theory. The problem of deriving an optimal price structure for cogenerated electricity and heat used for district heating in local communities is analyzed together with an attempt to measure short-run welfare gains of switching from the existing price structure in a stylized local community to the optimal price structure. A critical review presents concepts and methods used to assess the social costs of unsupplied electricity. Methods for dimensioning production capacity for electricity energy in an efficient way, and the problems of dimensioning production capacity for electricity in a socially optimal way are discussed. We then go on to examine the investment criteria used by the Swedish power industry. We also analyze criteria for appraisal of energy R and D projects from a governments perspective and present a model based on sequential decision making for evaluating uncertain energy R and D projects. (au) (138 refs., 45 figs. 18 tabs.)

  16. Life Cycle Multi-Criteria Analysis Of Alternative Energy Supply Systems For A Residential Building

    Directory of Open Access Journals (Sweden)

    Artur Rogoža

    2013-12-01

    Full Text Available The article analyses energy supply alternatives for a partially renovated residential building. In addition to the existing district heating (base case alternative systems, gas boilers, heat pumps (air-water and ground-water, solar collectors, solar cells, and combinations of these systems have been examined. Actual heat consumption of the building and electricity demand determined by the statistical method are used for simulating the systems. The process of simulation is performed using EnergyPro software. In order to select an optimal energy supply option, the life cycle analysis of all systems has been carried out throughout a life span of the building, and the estimated results of energy, environmental and economic evaluation have been converted into non-dimensional variables (3E using multi–criteria analysis.Article in Lithuanian

  17. Michigan residential No. 2 fuel oil and propane price survey for the 1990/91 heating season

    International Nuclear Information System (INIS)

    1991-10-01

    This report summarizes the results of a survey of home heating oil and propane prices over the 1990/1991 heating season in Michigan. The survey was conducted under a cooperative agreement between the State of Michigan, Michigan Public Service Commission and the US Department of Energy (DOE), Energy Information Administration (EIA), and was funded by a grant from EIA. From October 1990 through May 1991, participating dealers/distributions were called and asked for their current residential retail prices of No. 2 home heating oil and propane. This information was then transmitted to the EIA, bi-monthly using an electronic reporting system called Petroleum Data Reporting Option (PEDRO). The survey was conducted using a sample provided by EIA of home heating oil and propane retailers which supply Michigan households. These retailers were contacted the first and third Mondays of each month. The sample was designed to account for distributors with different sales volumes, geographic distributions and sources of primary supply. It should be noted that this simple is different from the sample used in prior year surveys

  18. Solar photovoltaic/thermal residential experiment. Phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Darkazalli, G.

    1980-07-01

    Month-by-month energy transfer data between an occupied residence and its energy supply systems are presented. The data were obtained during the first phase of photovoltaic/thermal residential research conducted at the University of Texas at Arlington/Solar Energy Research Facility. This research was part of the US Department of Energy Photovoltaic/Thermal Project managed by the M.I.T. Lincoln Laboratory. Energy transfer data are divided into different categories depending on how the energy is consumed. Energy transfers between some system components are also categorized. These components include a flat-plate thermal collector array, a flat-plate photovoltaic array, a dc-to-ac inverter, thermal storage tanks, and a series heat pump. System operations included directing surplus electrical energy (generated by the photovoltaic array) into the local utility grid. The heat pump used off-peak utility power to chill water during the cooling season.

  19. Electric heating systems - Measures and options for the reduction of electricity consumption; Elektroheizungen Massnahmen und Vorgehensoptionen zur Reduktion des Stromverbrauchs

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J.; Togni, G.

    2009-10-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at how electricity consumption for electrical heating systems can be reduced. The authors state that electric space heating consumes roughly 6% to 12% of Swiss electricity consumption, depending on the source of data. Important reduction potentials obtainable through the implementation of efficiency measures and substitution are well known. The results of two surveys on hardware installations and heating users' and utility companies' preferences are presented and discussed. The user survey yielded more than 900 evaluable answers. The main focus was on conditions considered necessary for changing a heating system. The utilities' survey was carried out by means of letters posted to 62 utilities, half of whom sent back evaluable answers. The main focus was on the number of dwellings supplied with electric space heating, current and past tariffs and utility activities to motivate customers to change their heating systems. The results showed that high investments necessary for a new heating system and additional thermal insulation of the building are the main obstacles for making changes. On the basis of the project's findings, a catalogue of measures was developed, whereby financial aspects and general conditions were taken into account.

  20. Feasibility study of a hybrid renewable energy system with geothermal and solar heat sources for residential buildings in South Korea

    International Nuclear Information System (INIS)

    Kim, Young Ju; Woo, Nam Sub; Jang, Sung Cheol; Choi, Jeong Ju

    2013-01-01

    This study investigates the economic feasibility of a hybrid renewable energy system (HRES) that uses geothermal and solar heat sources for water heating, space heating, and space cooling in a residential building in Korea. A small-scale HRES consists of a geothermal heat pump for heating and cooling, solar collectors for hot water, a gas-fired backup boiler, and incidental facilities. To determine whether the Hares will produce any economic benefits for homeowners, an economic analysis is conducted to compare the Hares with conventional methods of space heating and cooling in Korea. The payback period of a small-scale Hares is predicted as a maximum of 9 yrs by life cycle costing based on a performance index compared with conventional systems. However, the payback period of large-scale HRES above 400 RT is 6 yrs to 7 yrs.

  1. Feasibility study of a hybrid renewable energy system with geothermal and solar heat sources for residential buildings in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ju; Woo, Nam Sub [Korea Institute of Geoscience and Mineral Resources, Daejeon (Korea, Republic of); Jang, Sung Cheol [Mechatronics Department of the Korea Aviation Polytechnic College, Sacheon (Korea, Republic of); Choi, Jeong Ju [Dong-A University, Busan (Korea, Republic of)

    2013-08-15

    This study investigates the economic feasibility of a hybrid renewable energy system (HRES) that uses geothermal and solar heat sources for water heating, space heating, and space cooling in a residential building in Korea. A small-scale HRES consists of a geothermal heat pump for heating and cooling, solar collectors for hot water, a gas-fired backup boiler, and incidental facilities. To determine whether the Hares will produce any economic benefits for homeowners, an economic analysis is conducted to compare the Hares with conventional methods of space heating and cooling in Korea. The payback period of a small-scale Hares is predicted as a maximum of 9 yrs by life cycle costing based on a performance index compared with conventional systems. However, the payback period of large-scale HRES above 400 RT is 6 yrs to 7 yrs.

  2. Quantification of emissions from domestic heating in residential areas of İzmir, Turkey and assessment of the impact on local/regional air-quality

    International Nuclear Information System (INIS)

    Sari, Deniz; Bayram, Abdurrahman

    2014-01-01

    Air pollution in cities is a major environmental problem principally in the developing countries. The quantification of emissions is a basic requirement to assess the human influence to the atmosphere. The air quality generally shows decreases with the major contribution residential emissions and meteorology in the winter season in the big cities. Poor meteorological conditions especially inversion events for the efficient mixing of air pollutants occurred during the winter months in İzmir. With this work we quantify the amount of domestic heating emissions for particulate matter (PM10), sulfur dioxides (SO 2 ), nitrogen dioxides (NO 2 ), volatile organic compounds (VOC) and carbon monoxide (CO) together with greenhouse gases which are carbon dioxide (CO 2 ), nitrous oxide (N 2 O) and methane (CH 4 ) in İzmir for 2008–2009 winter season. The results showed that the most affected residential areas were central districts in the city center from domestic heating emissions due to meteorological condition and demographic reasons. Air quality modeling is a great tool for assisting policy makers how to decrease emissions and improve air quality. At the second part of the study, calculated emissions were modeled by using CALMET/CALPUFF dispersion modeling system and plotted in the form of air pollution maps by using geographical information system to determine the locations and estimate the effects of the new residential areas that will be established in the future in İzmir. - Highlights: • The air pollution in cities especially shows raises with the opening of winter season. • Air pollution has become a problem due to rapid urbanization in İzmir, Turkey. • The air quality shows decreases with the residential emissions in İzmir's winter. • With this work we quantify the amount of domestic heating emissions for pollutants. • The impact of emissions on local air-quality is determined by using dispersion model

  3. Renewable energy rebound effect?: Estimating the impact of state renewable energy financial incentives on residential electricity consumption

    Science.gov (United States)

    Stephenson, Beth A.

    Climate change is a well-documented phenomenon. If left unchecked greenhouse gas emissions will continue global surface warming, likely leading to severe and irreversible impacts. Generating renewable energy has become an increasingly salient topic in energy policy as it may mitigate the impact of climate change. State renewable energy financial incentives have been in place since the mid-1970s in some states and over 40 states have adopted one or more incentives at some point since then. Using multivariate linear and fixed effects regression for the years 2002 through 2012, I estimate the relationship between state renewable energy financial incentives and residential electricity consumption, along with the associated policy implications. My hypothesis is that a renewable energy rebound effect is present; therefore, states with renewable energy financial incentives have a higher rate of residential electricity consumption. I find a renewable energy rebound effect is present in varying degrees for each model, but the results do not definitively indicate how particular incentives influence consumer behavior. States should use caution when adopting and keeping renewable energy financial incentives as this may increase consumption in the short-term. The long-term impact is unclear, making it worthwhile for policymakers to continue studying the potential for renewable energy financial incentives to alter consumer behavior.

  4. Optimal Scheduling of Residential Microgrids Considering Virtual Energy Storage System

    Directory of Open Access Journals (Sweden)

    Weiliang Liu

    2018-04-01

    Full Text Available The increasingly complex residential microgrids (r-microgrid consisting of renewable generation, energy storage systems, and residential buildings require a more intelligent scheduling method. Firstly, aiming at the radiant floor heating/cooling system widely utilized in residential buildings, the mathematical relationship between the operative temperature and heating/cooling demand is established based on the equivalent thermodynamic parameters (ETP model, by which the thermal storage capacity is analyzed. Secondly, the radiant floor heating/cooling system is treated as virtual energy storage system (VESS, and an optimization model based on mixed-integer nonlinear programming (MINLP for r-microgrid scheduling is established which takes thermal comfort level and economy as the optimization objectives. Finally, the optimal scheduling results of two typical r-microgrids are analyzed. Case studies demonstrate that the proposed scheduling method can effectively employ the thermal storage capacity of radiant floor heating/cooling system, thus lowering the operating cost of the r-microgrid effectively while ensuring the thermal comfort level of users.

  5. Nuclear combined cycle gas turbines for variable electricity and heat using firebrick heat storage and low-carbon fuels

    International Nuclear Information System (INIS)

    Forsberg, Charles; Peterson, Per F.; McDaniel, Patrick; Bindra, Hitesh

    2017-01-01

    The world is transitioning to a low-carbon energy system. Variable electricity and industrial energy demands have been met with storable fossil fuels. The low-carbon energy sources (nuclear, wind and solar) are characterized by high-capital-costs and low-operating costs. High utilization is required to produce economic energy. Wind and solar are non-dispatchable; but, nuclear is the dispatchable energy source. Advanced combined cycle gas turbines with firebrick heat storage coupled to high-temperature reactors may enable economic variable electricity and heat production with constant full-power reactor output. Such systems efficiently couple to fluoride-salt-cooled high-temperature reactors (FHRs) with solid fuel and clean salt coolants, molten salt reactors (MSRs) with fuel dissolved in the salt coolant and salt-cooled fusion machines. Open Brayton combined cycles allow the use of natural gas, hydrogen, other fuels and firebrick heat storage for peak electricity production with incremental heat-to-electricity efficiencies from 66 to 70+% efficient. There are closed Brayton cycle options that use firebrick heat storage but these have not been investigated in any detail. Many of these cycles couple to high-temperature gas-cooled reactors (HTGRs). (author)

  6. Development of electrical heating in the Czech Republic and its consequences

    International Nuclear Information System (INIS)

    Mravinac, L.

    1996-01-01

    After 1990 the necessity to improve ecological conditions in the Czech Republic increased significantly. One of the measures to achieve this aim was the governmental support of households to replace fossil fuel heating by gas or electrical heating. This support, connected with the fact that prices of the electricity for households were and still are below a cost level resulted in a substantial increase of the electricity consumption of these consumers. This increase had a very unfavorable influence on the whole electrical system. While a consumption of industrial consumers had decreased after the year 1990 (as a result of changes in the national economy) and started to increase slowly only last year, the household consumption has recorded a continuous increase (of 17 % in 1994, for example). At present the installed capacity by direct electrical heating is estimated to amount up to 2200 MW while it was practically zero in 1991. The consumption diagram has accordingly changed. The difference between the summer minimum and the winter peak load has substantially increased. With nearly the same average consumption, the peak load in 1995 was about 800 Mw higher than in 1989. In the same period, the needed regulation capacity increased too. The increase in power demand for electrical heating will probably increase in the next years and accordingly new power capacities and new peak sources will be required. (author) 3 figs., 2 tabs

  7. Electric radiant heating: A hot item in home comfort

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2003-12-01

    Electric radiant heating as a floor warming system and its growing popularity in home comfort are discussed. Price can be as low as $2.00 per square foot; cost of operation may be as little as 30 cents per square foot per year, depending on time of use and local hydro rates. The use of radiant cable heating is said to have surged in popularity; it provides the same warmth and comfort as more expensive hydronic systems. Radiant cable is simple and inexpensive to install since unlike hydronic systems, it requires no complicated mechanical system with boiler, heat exchanger, valves, pumps and extensive controls. Nevertheless, prospective end users are warned to make sure that the cable is sturdy, tough, has multiple layers of protection with a thick grounding system and conductor core. In addition to heating floors, electric heating cables can also be used for snow and ice control and for melting in driveways and gutters. In these type of installations heavy duty cables are used which are installed under asphalt, concrete or interlocking stones. Thirty watts per square foot per hour is the typical requirement for melting snow and ice. Based on average electricity prices in Ontario, melting snow on an 800 square foot driveway would cost about $2.20 per hour. Assuming five hours for the system to clear the driveway, installing a heating system under the driveway could be an economically viable solution for the home owner, providing freedom from ice, the inconvenience of shovelling snow, and saving time and money.

  8. High temperature heat capacities and electrical conductivities of boron carbides

    International Nuclear Information System (INIS)

    Matsui, Tsuneo; Arita, Yuri; Naito, Keiji; Imai, Hisashi

    1991-01-01

    The heat capacities and the electrical conductivities of B x C(x=3, 4, 5) were measured by means of direct heating pulse calorimetry in the temperature range from 300 to 1500 K. The heat capacities of B x C increased with increasing x value. This increase in the heat capacity is probably related to the change of the lattice vibration mode originated from the reduction of the stiffness of the intericosahedral chain accompanied with a change from C-B-C to C-B-B chains. A linear relationship between the logarithm of σT (σ is the electrical conductivity and T is the absolute temperature) of B x C and the reciprocal temperature was observed, indicating the presence of small polaron hopping as the predominant conduction mechanism. The electrical conductivity of B x C also increased with increasing x value (from 4 to 5) due to an increase of the polaron hopping of holes between carbon atoms at geometrically nonequivalent sites, since these nonequivalent sites of carbon atoms were considered to increase in either B 11 C icosahedra or in icosahedral chains with increasing x. The electrical conductivity of B 3 C was higher than that of B 4 C, which is probably due to the precipitation of high-conducting carbon. The thermal conductivity and the thermodynamic quantities of B 4 C were also determined precisely from the heat capacity value. (orig.)

  9. Cold local heating. Agrothermal heat supply of an ecovillage; Kalt Nahwaerme. Agrothermische Waermeversorgung einer Plusenergiesiedlung

    Energy Technology Data Exchange (ETDEWEB)

    Pietruschka, Dirk [Hochschule fuer Technik Stuttgart (Germany). Forschungszentrum fuer Nachhaltige Energietechnik; Kluge, Juergen [Doppelacker GmbH, Petershagen-Eggersdorf (Germany)

    2013-03-01

    An ecovillage with highly efficient residential buildings is arisen in the Swabian community Wuestenrot. The power generation in these residential buildings by means of photovoltaic power plants is greater than the energy consumption. Decentralized heat plants supply thermal energy for the space heating and industrial waste. Central agrothermal collectors provide the necessary low-temperature heat for the effective operation of heat pumps over a so-called cold heat grid.

  10. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    International Nuclear Information System (INIS)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-01-01

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER

  11. Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Gregory; Chan, Peter; Lekov, Alex; McMahon, James; Van Buskirk, Robert

    2001-10-10

    In support of the federal government's efforts to raise the minimum energy-efficiency standards for residential-type central air conditioners and heat pumps, a consumer life-cycle cost (LCC) analysis was conducted to demonstrate the economic impacts on individual consumers from revisions to the standards. LCC is the consumer's cost of purchasing and installing an air conditioner or heat pump and operating the unit over its lifetime. The LCC analysis is conducted on a nationally representative sample of air conditioner and heat pump consumers resulting in a distribution of LCC impacts showing the percentage of consumers that are either benefiting or being burdened by increased standards. Relative to the existing minimum efficiency standard of 10 SEER, the results show that a majority of split system air conditioner and heat pump consumers will either benefit or be insignificantly impacted by increased efficiency standards of up to 13 SEER.

  12. 75 FR 12144 - Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential...

    Science.gov (United States)

    2010-03-15

    .... 1. Consensus Agreement On January 26, 2010, the Air-Conditioning, Heating and Refrigeration... subsections. B. History of the Standards Rulemaking for Residential Furnaces 1. Background Energy conservation... recommending minimum energy conservation standards for residential central air conditioners, heat pumps, and...

  13. Electric heating of religious buildings; Chauffage des lieux de culte par l`electricite

    Energy Technology Data Exchange (ETDEWEB)

    Jicquel, J M; Collober, M; Veyrat, O [Electricite de France, 92 - Clamart (France). Direction des Etudes et Recherches

    1997-06-01

    This paper reports on in-situ measurements performed in churches which allow to retain interesting solutions for electric heating. Churches are characterized by an important thermal inertia, a huge volume, an intermittency of use (some few hours a week) and by thermal, physical and chemical constraints for the good preservation of works of art and general esthetics of the building, in particular in the case of listed historical monuments. The installation of heating systems in such monuments requires authorizations from the historical monuments, the sacred art and the safety commissions. This paper summarizes the regulations and recommendations concerning: the thermal insulation, the heating regulation and programming, the ventilation, the fire safety, the electrical installation and the lighting. Then, the available electric powered heating systems are reviewed and described in details (principle, dimension, regulation, domain of use, installation): radiant short-infrared emitters, heating moquettes and heating pews. The choice criteria for a given heating system are analyzed according to the different constraints of the building (size, architecture, regulations, comfort, consumption costs) and finally the advantages of electric power heating are listed (no combustion products, low temperature stratification, aesthetics, silence and service life). (J.S.)

  14. Wind power integration with heat pumps, heat storages, and electric vehicles – Energy systems analysis and modelling

    DEFF Research Database (Denmark)

    Hedegaard, Karsten

    The fluctuating and only partly predictable nature of wind challenges an effective integration of large wind power penetrations. This PhD thesis investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing...... in an energy system context. Energy systems analyses reveal that the heat pumps can even without flexible operation contribute significantly to facilitating larger wind power investments and reducing system costs, fuel consumption, and CO2 emissions. When equipping the heat pumps with heat storages, only...... moderate additional benefits are achieved. Hereof, the main benefit is that the need for investing in peak/reserve capacities can be reduced through peak load shaving. It is more important to ensure flexible operation of electric vehicles than of individual heat pumps, due to differences in the load...

  15. Thermal to Electric Energy Conversion for Cyclic Heat Loads

    Science.gov (United States)

    Whitehead, Benjamin E.

    Today, we find cyclic heat loads almost everywhere. When we drive our cars, the engines heat up while we are driving and cool while parked. Processors heat while the computer is in use at the office and cool when idle at night. The sun heats the earth during the day and the earth radiates that heat into space at night. With modern technology, we have access to a number of methods to take that heat and convert it into electricity, but, before selecting one, we need to identify the parameters that inform decision making. The majority of the parameters for most systems include duty cycle, total cost, weight, size, thermal efficiency, and electrical efficiency. However, the importance of each of these will depend on the application. Size and weight take priority in a handheld device, while efficiency dominates in a power plant, and duty cycle is likely to dominate in highly demanding heat pump applications. Over the past decade, developments in semiconductor technology has led to the creation of the thermoelectric generator. With no moving parts and a nearly endlessly scalable nature, these generators present interesting opportunities for taking advantage of any source of waste heat. However, these generators are typically only capable of 5-8% efficiency from conversion of thermal to electric energy. [1]. Similarly, advancements in photovoltaic cells has led to the development of thermophotovoltaics. By heating an emitter to a temperature so it radiates light, a thermophotovoltaic cell then converts that light into electricity. By selecting materials that emit light in the optimal ranges of the appropriate photovoltaic cells, thermophotovoltaic systems can potentially exceed the current maximum of 10% efficiency. [2]. By pressurizing certain metal powders with hydrogen, hydrogen can be bound to the metal, creating a metal hydride, from which hydrogen can be later re-extracted under the correct pressure and temperature conditions. Since this hydriding reaction is

  16. Life cycle assessment of domestic heat pump hot water systems in Australia

    Directory of Open Access Journals (Sweden)

    Moore Andrew D.

    2017-01-01

    Full Text Available Water heating accounts for 23% of residential energy consumption in Australia, and, as over half is provided by electric water heaters, is a significant source of greenhouse gas emissions. Due to inclusion in rebate schemes heat pump water heating systems are becoming increasingly popular, but do they result in lower greenhouse gas emissions? This study follows on from a previous life cycle assessment study of domestic hot water systems to include heat pump systems. The streamlined life cycle assessment approach used focused on the use phase of the life cycle, which was found in the previous study to be where the majority of global warming potential (GWP impacts occurred. Data was collected from an Australian heat pump manufacturer and was modelled assuming installation within Australian climate zone 3 (AS/NZS 4234:2011. Several scenarios were investigated for the heat pumps including different sources of electricity (grid, photovoltaic solar modules, and batteries and the use of solar thermal panels. It was found that due to their higher efficiency heat pump hot water systems can result in significantly lower GWP than electric storage hot water systems. Further, solar thermal heat pump systems can have lower GWP than solar electric hot water systems that use conventional electric boosting. Additionally, the contributions of HFC refrigerants to GWP can be significant so the use of alternative refrigerants is recommended. Heat pumps combined with PV and battery technology can achieve the lowest GWP of all domestic hot water systems.

  17. Seminar on heat pump research and applications: proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Steele, R.V. Jr. (ed.)

    1984-11-01

    This volume is a compilation of papers prepared by speakers at a seminar on heat pumps. The seminar was organized by the Electric Power Research Institute (EPRI) in cooperation with Louisiana Power and Light Company and New Orleans Public Service, Inc. The seminar's purpose was to inform utility managers and engineers of the most recent developments in residential heat pump technology and applications. Statements by invited panelists on the outlook for heat pump technology are also included. The speakers, who represented key organizations in the heat pump area, including utilities, industry associations, manufacturers, independent research institutes, government, and EPRI, addressed the following topics: status of heat pump research and development, heat pump testing and rating; field monitoring of heat pumps; heat pump water heaters; heat pump reliability; and marketing programs for pumps. All papers, total of sixteen have been processed for inclusion in the Energy Data Base.

  18. Economics of residential solar hot water heating systems in Malaysia

    International Nuclear Information System (INIS)

    Abdulmula, Ahmed Mohamed Omer; Sopian, Kamaruzzaman; Haj Othman, Mohd Yosof

    2006-01-01

    Malaysia has favorable climatic conditions for the development of solar energy due to the abundant sunshine and is considered good for harnessing energy from the sun. This is because solar hot water can represent the large energy consumer in Malaysian households but, because of the high initial cost of Solar Water Heating Systems (SWHSs) and easily to install and relatively inexpensive to purchase electric water heaters, many Malyaysian families are still using Electric Water Heaters to hot their water needs. This paper is presented the comparing of techno-economic feasibility of some models of SWHS from Malaysian's market with the Electric Water Heaters )EWH) by study the annual cost of operation for both systems. The result shows that the annual cost of the electrical water heater becomes greater than than the annual cost of the SWHS for all models in long-team run so it is advantageous for the family to use the solar water heater, at least after 4 years. In addition with installation SWHS the families can get long-term economical benefits, environment friendly and also can doing its part to reduce this country's dependence on foreign oil that is price increase day after day.(Author)

  19. Development of Residential SOFC Cogeneration System

    International Nuclear Information System (INIS)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-01-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the 'Demonstrative Research on Solid Oxide Fuel Cells' Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  20. Development of Residential SOFC Cogeneration System

    Science.gov (United States)

    Ono, Takashi; Miyachi, Itaru; Suzuki, Minoru; Higaki, Katsuki

    2011-06-01

    Since 2001 Kyocera has been developing 1kW class Solid Oxide Fuel Cell (SOFC) for power generation system. We have developed a cell, stack, module and system. Since 2004, Kyocera and Osaka Gas Co., Ltd. have been developed SOFC residential co-generation system. From 2007, we took part in the "Demonstrative Research on Solid Oxide Fuel Cells" Project conducted by New Energy Foundation (NEF). Total 57 units of 0.7kW class SOFC cogeneration systems had been installed at residential houses. In spite of residential small power demand, the actual electric efficiency was about 40%(netAC,LHV), and high CO2 reduction performance was achieved by these systems. Hereafter, new joint development, Osaka Gas, Toyota Motors, Kyocera and Aisin Seiki, aims early commercialization of residential SOFC CHP system.

  1. Hydride heat pump. Volume I. Users manual for HYCSOS system design program. [HYCSOS code

    Energy Technology Data Exchange (ETDEWEB)

    Gorman, R.; Moritz, P.

    1978-05-01

    A method for the design and costing of a metal hydride heat pump for residential use and a computer program, HYCSOS, which automates that method are described. The system analyzed is one in which a metal hydride heat pump can provide space heating and space cooling powered by energy from solar collectors and electric power generated from solar energy. The principles and basic design of the system are presented, and the computer program is described giving detailed design and performance equations used in the program. The operation of the program is explained, and a sample run is presented. This computer program is part of an effort to design, cost, and evaluate a hydride heat pump for residential use. The computer program is written in standard Fortran IV and was run on a CDC Cyber 74 and Cyber 174 computer. A listing of the program is included as an appendix. This report is Volume 1 of a two-volume document.

  2. 75 FR 20111 - Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct...

    Science.gov (United States)

    2010-04-16

    ... Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool... heating equipment and pool heaters. Table I.1--Amended Energy Conservation Standards for Residential Water... for national energy and water conservation; and 7. Other factors the Secretary of Energy (Secretary...

  3. Mitigation of the Impact of High Plug-in Electric Vehicle Penetration on Residential Distribution Grid Using Smart Charging Strategies

    Directory of Open Access Journals (Sweden)

    Chong Cao

    2016-12-01

    Full Text Available Vehicle electrification presents a great opportunity to reduce transportation greenhouse gas emissions. The greater use of plug-in electric vehicles (PEVs, however, puts stress on local distribution networks. This paper presents an optimal PEV charging control method integrated with utility demand response (DR signals to mitigate the impact of PEV charging to several aspects of a grid, including load surge, distribution accumulative voltage deviation, and transformer aging. To build a realistic PEV charging load model, the results of National Household Travel Survey (NHTS have been analyzed and a stochastic PEV charging model has been defined based on survey results. The residential distribution grid contains 120 houses and is modeled in GridLAB-D. Co-simulation is performed using Matlab and GridLAB-D to enable the optimal control algorithm in Matlab to control PEV charging loads in the residential grid modeled in GridLAB-D. Simulation results demonstrate the effectiveness of the proposed optimal charging control method in mitigating the negative impacts of PEV charging on the residential grid.

  4. INVESTIGATION OF HEAT CONDUCTION AND SPECIFIC ELECTRIC IMPEDANCE OF POROUS MATERIALS

    Directory of Open Access Journals (Sweden)

    E. S. Golubtsova

    2004-01-01

    Full Text Available In this article there was investigated the influence of porosity and temperature change on heat condition and electrical resistance of porous iron (PZh4M nickel and steel 14X17H2. There are received the adequate equations of regression, establishing connection between heat conduction and electrical resistance of the investigated materials with their porosity and temperature.

  5. Recouping the thermal-to-electric conversion loss by the use of waste heat

    International Nuclear Information System (INIS)

    Bradley, W.J.

    1976-01-01

    This paper looks at ways to recoup the thermal-to-electric conversion loss of our thermal power generating stations. These stations now produce twice as much low-grade waste heat as they do electricity. We can improve the situation in two ways: by improving the station efficiency, and by utilizing the low-grade heat beneficially. The following options are examined: N 2 O 4 turbines condensing at 10 deg C; power from moderator waste heat; 50 MW heat pump for district heating; industrial parks with integrated waste heat upgrading station. (author)

  6. Architectural design of passive solar residential building

    Directory of Open Access Journals (Sweden)

    Ma Jing

    2015-01-01

    Full Text Available This paper studies thermal environment of closed balconies that commonly exist in residential buildings, and designs a passive solar residential building. The design optimizes the architectural details of the house and passive utilization of solar energy to provide auxiliary heating for house in winter and cooling in summer. This design might provide a more sufficient and reasonable modification for microclimate in the house.

  7. District heating development, air quality improvement, and cogeneration in Krakow, Poland

    International Nuclear Information System (INIS)

    Manczyk, H.; Leach, M.D.

    1992-01-01

    Krakow, Poland, is served by a district heating system that includes coal-fired electrical and heating plants and distribution networks and by approximately 200,000 residential coal furnaces. Cogeneration facilities were added in the mid-1970s to supply up to 40% of the regional peak electrical demand and to optimize energy extraction from the low-heating-value coal mined in the region. Several difficulties prevent the district from realizing the potential efficiencies of its technology: the poor condition of the distribution network, the lack of consumption control and metering devices, inadequate plant maintenance, and the lack of economic incentives for operator productivity and energy conservation by users. Environmental concerns have caused the local government and international agencies to plan major improvements to the system. This paper discusses the development of the district heating system, coal use in Poland, cogeneration facilities, environmental concerns and pollution control plans, and improvement strategies

  8. Determining of the optimal design of a closed loop solar dual source heat pump system coupled with a residential building application

    International Nuclear Information System (INIS)

    Chargui, Ridha; Awani, Sami

    2017-01-01

    Graphical abstract: Operation of the system in heating mode. - Highlights: • We examine the control function in the level of heat pump and collector. • We examine the temporal evolution of the temperature and energy in the all components of the system. • A better system with a significant energy saving was achieved. • The system gives good results in all operating states. - Abstract: This work highlights the results on the coupling of a flat plate collector coupled with a dual source heat pump system and a heat exchanger for building application. The novelty point of this work is to integrate a heat exchanger in the floor and in the interstitial space of the residential house roof in order to minimize the consumed electric power. This technology defining the operational state of the system has been developed and adapted in the present investigation by adopting the Tunisian climate. The dimensioning of this installation for different component makes it possible to operate the hot water heating systems ecologically. Hence, our objective is to ameliorate the performance of the system using the solar radiation converted to the thermal energy in the level of the flat plate collector and the heat pump. A several experimental data have been added for realizing a numerical model based on TRNSYS software. From this point of view, a numerical model was improved in building application using a 150 m 2 as surface area of the building which consists of two floor zones. The dual source heat pump was coupled with a ground heat exchanger (GHE) with 0.2 m of depth. The distance between two consecutive tubes is 0.3 m and the surface area of the solar collector is 8 m 2 . The simulation results have been obtained for 48 h operation in January and all inputs data of the system have been predicted during 48 h and 6 months of heating in Tunisia. It was demonstrated that the COP of the dual source heat pump was enhanced with the increase of the solar radiation during the typical

  9. Electric heating of a unit for uranium trioxide production

    International Nuclear Information System (INIS)

    Faron, R.; Striff, A.

    1985-01-01

    Ammonium diuranate U 2 O 7 (NH 4 ) 2 containing about 50% of water is dried and transformed by calcination in uranium trioxide UO 3 . Drying and calcination was obtained by air heated by two burners using domestic fuel. In 1984 the plant was transformed for utilization of electric heating improving maintenance cost, decreasing heat losses and by energy saving the payback period on investment is of 2.6 years [fr

  10. Indoor temperature changes after retrofit: inferences based on electricity billing data for nonparticipants and participants in the BPA Residential Weatherization Program

    Energy Technology Data Exchange (ETDEWEB)

    Hirst, E.; White, D.

    1985-07-01

    This report discusses changes in indoor temperatures in response to retrofit improvements. The data on which this analysis is based are from an evaluation of the Bonneville Power Administration (BPA) interim Residential Weatherization Program. The BPA program, operated through participating private and public utilities throughout the Pacific Northwest, offered financial assistance (generally a cash rebate) to encourage installation of energy-efficiency improvements to existing homes in the region. These retrofits included attic, wall, floor and heating duct insulation; storm windows and doors; clock thermostats; and caulking and weatherstripping. This program, which operated during 1982 and 1983, weatherized 104 thousand homes at a total cost to BPA of $157 million. In mid-1983, staff at Oak Ridge National Laboratory and Evaluation Research Corporation began an evaluation of the BPA program. The primary focus of this evaluation was assessment of the actual electricity saving that can be attributed to the program (Hirst, et al., 1985). These savings estimates were used to help assess the economic attractiveness of the program to participants, the BPA power system, and the Pacific Northwest region as a whole.

  11. Electric Boiler and Heat Pump Thermo-Electrical Models for Demand Side Management Analysis in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte; Chen, Zhe

    2013-01-01

    The last fifteen years many European countries have integrated large percentage of renewable energy on their electricity generation mix. In Denmark the 21.3% of the electricity consumed nowadays is produced by the wind, and it has planned to be the 50% by 2025. In order to front future challenges...... on the power system control and operation, created by this unstable way of generation, Demand Side Management turns to be a promising solution. The storage capacity from thermo-electric units, like electric boilers and heat pumps, allows operating them with certain freedom. Hence they can be employed under...... certain coordination, to actively respond to the power system fluctuations. The following paper presents two simple thermo-electrical models of an electrical boiler and an air-source CO2 heat pump system. The purpose is using them in low voltage grids analysis to assess their capacity and flexibility...

  12. Impact of roof integrated PV orientation on the residential electricity peak demand

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Atallah, Fady; Boehm, Robert F.

    2012-01-01

    Highlights: ► A study to demonstrate peak load reductions at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 38% through energy efficiency. ► Orientation of roof integrated PV has less influence on the summer peak demand. ► Increasing thermostat temperature during peak by 1 °C can significantly reduce peaks. -- Abstract: Peak electricity demand has been an issue in the Desert Southwest region of the US, due to extreme summer temperatures. To address this issue, a consortium was formed between the University of Nevada, Las Vegas, Pulte Homes, and NV Energy. An energy efficient residential community was developed by the team in Las Vegas with approximately 200 homes to study substation-level peak reduction strategies. A summer peak reduction of more than 65%, between 1:00 PM and 7:00 PM, compared to code standard housing developments is the targeted goal of the project. Approximately 50 homes are already built and some are occupied. The energy performances of the homes have been monitored and are presented in this paper. Several peak electric load reduction strategies such as energy efficiency in buildings, roof integrated photovoltaics (PV) and direct load control have been applied. Though all the homes in the developed community are installed with 1.8 kW p PV systems, the orientation of the PV system depends on the building orientation. Focus of this paper is to find the impact of PV orientation on the peak load from a building. In addition, different time-of-use (TOU) energy pricing options are offered by the local electrical utility company. Hence it is important to find an optimal pricing option for each building. A computer model has been developed for one of the homes in the new development using building energy simulation code, ENERGY-10. Calculations on the PV orientations have shown that a south and 220° (i.e. 40° west of due south

  13. Energy literacy, awareness, and conservation behavior of residential households

    International Nuclear Information System (INIS)

    Brounen, Dirk; Kok, Nils; Quigley, John M.

    2013-01-01

    The residential sector accounts for one-fifth of global energy consumption, resulting from the requirements to heat, cool, and light residential dwellings. It is therefore not surprising that energy efficiency in the residential market has gained importance in recent years. In this paper, we examine awareness, literacy and behavior of households with respect to their residential energy expenditures. Using a detailed survey of 1721 Dutch households, we measure the extent to which consumers are aware of their energy consumption and whether they have taken measures to reduce their energy costs. Our results show that “energy literacy” and awareness among respondents is low: just 56% of the respondents are aware of their monthly charges for energy consumption, and 40% do not appropriately evaluate investment decisions in energy efficient equipment. We document that demographics and consumer attitudes towards energy conservation, but not energy literacy and awareness, have direct effects on behavior regarding heating and cooling of the home. The impact of a moderating factor, measured by thermostat settings, ultimately results in strong variation in the energy consumption of private consumers. - Highlights: • We use a detailed survey of 1,721 Dutch households to measure awareness and conservation behavior in energy consumption. • Energy literacy and awareness among residential households is low. • 40 percent of the sample does not appropriately evaluate investment decisions in energy efficient equipment • Demographics and consumer attitudes affect behavior regarding heating and cooling of a home

  14. Electrification Opportunities in the Transportation Sector and Impact of Residential Charging

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-04

    This presentation provides an overview of electrification opportunities in the transportation sector and present results of a study assessing the impact of residential charging on residential power demand and electric power distribution infrastructure.

  15. GREEN RETROFITTING RESIDENTIAL BUILDINGS

    Science.gov (United States)

    When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...

  16. Residential outage cost estimation: Hong Kong

    International Nuclear Information System (INIS)

    Woo, C.K.; Ho, T.; Shiu, A.; Cheng, Y.S.; Horowitz, I.; Wang, J.

    2014-01-01

    Hong Kong has almost perfect electricity reliability, the result of substantial investments ultimately financed by electricity consumers who may be willing to accept lower reliability in exchange for lower bills. But consumers with high outage costs are likely to reject the reliability reduction. Our ordered-logit regression analysis of the responses by 1876 households to a telephone survey conducted in June 2013 indicates that Hong Kong residents exhibit a statistically-significant preference for their existing service reliability and rate. Moreover, the average residential cost estimate for a 1-h outage is US$45 (HK$350), topping the estimates reported in 10 of the 11 studies published in the last 10 years. The policy implication is that absent additional compelling evidence, Hong Kong should not reduce its service reliability. - Highlights: • Use a contingent valuation survey to obtain residential preferences for reliability. • Use an ordered logit analysis to estimate Hong Kong's residential outage costs. • Find high outage cost estimates that imply high reliability requirements. • Conclude that sans new evidence, Hong Kong should not reduce its reliability

  17. Residential and commercial space heating and cooling with possible greenhouse operation; Baca Grande development, San Luis Valley, Colorado. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Goering, S.W.; Garing, K.L.; Coury, G.E.; Fritzler, E.A.

    1980-05-01

    A feasibility study was performed to evaluate the potential of multipurpose applications of moderate-temperature geothermal waters in the vicinity of the Baca Grande community development in the San Luis Valley, Colorado. The project resource assessment, based on a thorough review of existing data, indicates that a substantial resource likely exists in the Baca Grande region capable of supporting residential and light industrial activity. Engineering designs were developed for geothermal district heating systems for space heating and domestic hot water heating for residences, including a mobile home park, an existing motel, a greenhouse complex, and other small commercial uses such as aquaculture. In addition, a thorough institutional analysis of the study area was performed to highlight factors which might pose barriers to the ultimate commercial development of the resource. Finally, an environmental evaluation of the possible impacts of the proposed action was also performed. The feasibility evaluation indicates the economics of the residential areas are dependent on the continued rate of housing construction. If essentially complete development could occur over a 30-year period, the economics are favorable as compared to existing alternatives. For the commercial area, the economics are good as compared to existing conventional energy sources. This is especially true as related to proposed greenhouse operations. The institutional and environmental analyses indicates that no significant barriers to development are apparent.

  18. Estimation of Residential Heat Pump Consumption for Flexibility Market Applications

    DEFF Research Database (Denmark)

    Kouzelis, Konstantinos; Tan, Zheng-Hua; Bak-Jensen, Birgitte

    2015-01-01

    load of a flexible device, namely a Heat Pump (HP), out of the aggregated energy consumption of a house. The main idea for accomplishing this, is a comparison of the flexible consumer with electrically similar non-flexible consumers. The methodology is based on machine learning techniques, probability...... theory and statistics. After presenting this methodology, the general trend of the HP consumption is estimated and an hour-ahead forecast is conducted by employing Seasonal Autoregressive Integrated Moving Average modeling. In this manner, the flexible consumption is predicted, establishing the basis......Recent technological advancements have facilitated the evolution of traditional distribution grids to smart grids. In a smart grid scenario, flexible devices are expected to aid the system in balancing the electric power in a technically and economically efficient way. To achieve this, the flexible...

  19. An adopter-centric approach to analyze the diffusion patterns of innovative residential heating systems in Sweden

    International Nuclear Information System (INIS)

    Mahapatra, Krushna; Gustavsson, Leif

    2008-01-01

    Innovation and diffusion of renewable energy technologies play a major role in mitigation of climate change. In Sweden replacing electric and oil heating systems with innovative heating systems such as district heating, heat pumps and wood pellet boilers in detached homes is a significant mitigation option. Using an adopter-centric approach, we analyzed the influence of investment subsidy on conversion of resistance heaters and oil boilers, and the variation in diffusion pattern of district heating, heat pumps and pellet boilers in Swedish detached homes. Results from questionnaire surveys of 1500 randomly selected homeowners in September 2004 and January 2007 showed that more than 80% of the respondents did not intend to install a new heating system. Hence, about 37% of the homeowners still have electric and oil heating systems. The government investment subsidy was important for conversion from a resistance heater, but not from an oil boiler. This is because homeowners currently replacing their oil boilers are the laggards, while those replacing resistance heaters are the 'early adopters'. Economic aspects and functional reliability were the most important factors for the homeowners when considering a new heating system. There is a variation in the perceived advantages associated with each of the innovative heating systems and therefore, the diffusion patterns of such systems vary. Installers and interpersonal sources were the most important communication channels for information on heating systems

  20. An adopter-centric approach to analyze the diffusion patterns of innovative residential heating systems in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, Krushna; Gustavsson, Leif [Ecotechnology, Mid Sweden University, 831 25 Oestersund (Sweden)

    2008-02-15

    Innovation and diffusion of renewable energy technologies play a major role in mitigation of climate change. In Sweden replacing electric and oil heating systems with innovative heating systems such as district heating, heat pumps and wood pellet boilers in detached homes is a significant mitigation option. Using an adopter-centric approach, we analyzed the influence of investment subsidy on conversion of resistance heaters and oil boilers, and the variation in diffusion pattern of district heating, heat pumps and pellet boilers in Swedish detached homes. Results from questionnaire surveys of 1500 randomly selected homeowners in September 2004 and January 2007 showed that more than 80% of the respondents did not intend to install a new heating system. Hence, about 37% of the homeowners still have electric and oil heating systems. The government investment subsidy was important for conversion from a resistance heater, but not from an oil boiler. This is because homeowners currently replacing their oil boilers are the laggards, while those replacing resistance heaters are the 'early adopters'. Economic aspects and functional reliability were the most important factors for the homeowners when considering a new heating system. There is a variation in the perceived advantages associated with each of the innovative heating systems and therefore, the diffusion patterns of such systems vary. Installers and interpersonal sources were the most important communication channels for information on heating systems. (author)

  1. Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States). Building America Partnership for Improved Residential Construction (BA-PIRC)

    2017-07-01

    The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

  2. Experimental characterization, modeling and simulation of a wood pellet micro-combined heat and power unit used as a heat source for a residential building

    Energy Technology Data Exchange (ETDEWEB)

    Thiers, Stephane; Aoun, Bernard; Peuportier, Bruno [MINES ParisTech, CEP - Centre Energetique et Procedes, 60 Boulevard St Michel, 75272 Paris Cedex 06 (France)

    2010-06-15

    Cogeneration provides heat and power in a more efficient way than separate production. Micro-cogeneration (micro-CHP) is an emerging solution for the improvement of energy and environmental assessments of residential buildings. A wood pellet Stirling engine micro-CHP unit has been studied in order to characterize its annual performance when integrated to a building. First, through a test bench experiment, both transient and steady state behaviors of the micro-CHP unit have been characterized and modeled. Then a more complete model representing a hot water and heating system including the micro-CHP unit and a stratified storage tank has been carried out. This model has been coupled to a building model. A sensitivity analysis by simulation shows that the dimensioning of different elements of the system strongly influences its global energy performance. (author)

  3. Smart Grid enabled heat pumps

    DEFF Research Database (Denmark)

    Carmo, Carolina; Detlefsen, Nina; Nielsen, Mads Pagh

    2014-01-01

    The transition towards a 100 % fossil-free energy system, while achieving extreme penetration levels of intermittent wind and solar power in electricity generation, requires demand-side technologies that are smart (intermittency-friendly) and efficient. The integration of Smart Grid enabling...... with an empirical study in order to achieve a number of recommendations with respect to technology concepts and control strategies that would allow residential vapor-compression heat pumps to support large-scale integration of intermittent renewables. The analysis is based on data gathered over a period of up to 3...

  4. The role of domestic biomass in electricity, heat and grid balancing markets in Switzerland

    International Nuclear Information System (INIS)

    Panos, Evangelos; Kannan, Ramachandran

    2016-01-01

    The Swiss Energy Strategy targets to reduce per capita energy consumption, to decrease the share of fossil energy and to replace nuclear electricity generation by gains in efficiency and renewable energy sources. In view of the above objectives, we evaluated the prospects of biomass in stationary applications and grid balancing from an energy system perspective. We quantify a number of “what-if” scenarios using a cost-optimisation bottom-up model, with detailed representation of biomass production and use pathways, electricity and heat sectors, and grid ancillary services markets. The scenario analysis shows that domestic biomass can contribute 5–7% in electricity and 14–21% in heat production by 2050, depending on natural gas prices and climate policy intensity. Pooling of biogenic driven cogeneration plants can provide about 22–44% of the total secondary control power in 2050. Generally, biogenic technologies complement other assets in heat, electricity and ancillary services markets such as heat pumps, new renewable sources and hydropower. - Highlights: • Development and application of the Swiss TIMES electricity and heat system model. • Bioenergy supplies 5–7% of electricity and 14–21% of heat by 2050. • Biogenic gas driven CHP can provide 22–44% of secondary control power in 2050.

  5. Residential Photovoltaic/Thermal Energy System

    Science.gov (United States)

    Selcuk, M. K.

    1987-01-01

    Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

  6. Design and Testing of a Thermal Storage System for Electric Vehicle Cabin Heating

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Mingyu [MAHLE Behr Troy Inc.; WolfeIV, Edward [MAHLE Behr Troy Inc.; Craig, Timothy [MAHLE Behr Troy Inc.; LaClair, Tim J [ORNL; Gao, Zhiming [ORNL; Abdelaziz, Omar [ORNL

    2016-01-01

    Without the waste heat available from the engine of a conventional automobile, electric vehicles (EVs) must provide heat to the cabin for climate control using energy stored in the vehicle. In current EV designs, this energy is typically provided by the traction battery. In very cold climatic conditions, the power required to heat the EV cabin can be of a similar magnitude to that required for propulsion of the vehicle. As a result, the driving range of an EV can be reduced very significantly during winter months, which limits consumer acceptance of EVs and results in increased battery costs to achieve a minimum range while ensuring comfort to the EV driver. To minimize the range penalty associated with EV cabin heating, a novel climate control system that includes thermal energy storage has been designed for use in EVs and plug-in hybrid electric vehicles (PHEVs). The system uses the stored latent heat of an advanced phase change material (PCM) to provide cabin heating. The PCM is melted while the EV is connected to the electric grid for charging of the electric battery, and the stored energy is subsequently transferred to the cabin during driving. To minimize thermal losses when the EV is parked for extended periods, the PCM is encased in a high performance insulation system. The electrical PCM-Assisted Thermal Heating System (ePATHS) was designed to provide enough thermal energy to heat the EV s cabin for approximately 46 minutes, covering the entire daily commute of a typical driver in the U.S.

  7. Heat supply systems using natural gas in the residential sector: The case of the agglomeration of Seoul

    International Nuclear Information System (INIS)

    Park, Hi-Chun; Kim, Hoseok

    2008-01-01

    Combined heat and power (CHP) and district heating (DH) promotion policies are based on the assumption of high energy efficiencies. In the last two decades, however, there has been a big increase in energy efficiencies of combined-cycle gas power plants (CCs) including CHPs and gas-condensing boilers. This study tries to verify the validity of the assumption of high energy efficiency of DH. The experience in the agglomeration of Seoul shows that DH in combination with large modern CHPs is not more energy efficient but substantially more expensive compared to individual gas heating by efficient condensing boilers in combination with CCs. We argue that the Korean government should review its CHP/DH support programs and abandon the so-called heat supply monopoly for DH operators in newly developed residential areas. Such a policy intervention only distorts the space heating market and wastes valuable financial resources. Furthermore, the public should be properly informed on energy efficiency as well as energy- and system-related costs of various heat supply systems. In the light of the present improvements in the performance of gas-condensing boilers and CCs, the validity of the assumption of high energy efficiency of CHP/DH in other countries has to be reviewed

  8. Proceedings of the 1998 oil heat technology conference

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, R.J.

    1998-04-01

    The 1998 Oil Heat Technology Conference was held on April 7--8 at Brookhaven National Laboratory (BNL) under sponsorship by the US Department of Energy, Office of Building Technologies, State and Community Programs (DOE/BTS). The meeting was held in cooperation with the Petroleum Marketers Association of America (PMAA). Fourteen technical presentations was made during the two-day program, all related to oil-heat technology and equipment, these will cover a range of research, developmental, and demonstration activities being conducted within the United States and Canada, including: integrated oil heat appliance system development in Canada; a miniature heat-actuated air conditioner for distributed space conditioning; high-flow fan atomized oil burner (HFAB) development; progress in the development of self tuning oil burners; application of HFAB technology to the development of a 500 watt; thermophotovoltaic (TPV) power system; field tests of the Heat Wise Pioneer oil burner and Insight Technologies AFQI; expanded use of residential oil burners to reduce ambient ozone and particulate levels by conversion of electric heated homes to oilheat; PMAA`s Oil Heat Technician`s Manual (third edition); direct venting concept development; evolution of the chimney; combating fuel related problems; the effects of red dye and metal contamination on fuel oil stability; new standard for above ground and basement residential fuel oil storage; plastic and steel composite secondary contained tanks; and money left on the table: an economic analysis of tank cleaning.

  9. Introducing a demand-based electricity distribution tariff in the residential sector: Demand response and customer perception

    International Nuclear Information System (INIS)

    Bartusch, Cajsa; Wallin, Fredrik; Odlare, Monica; Vassileva, Iana; Wester, Lars

    2011-01-01

    Increased demand response is essential to fully exploit the Swedish power system, which in turn is an absolute prerequisite for meeting political goals related to energy efficiency and climate change. Demand response programs are, nonetheless, still exceptional in the residential sector of the Swedish electricity market, one contributory factor being lack of knowledge about the extent of the potential gains. In light of these circumstances, this empirical study set out with the intention of estimating the scope of households' response to, and assessing customers' perception of, a demand-based time-of-use electricity distribution tariff. The results show that households as a whole have a fairly high opinion of the demand-based tariff and act on its intrinsic price signals by decreasing peak demand in peak periods and shifting electricity use from peak to off-peak periods. - Highlights: → Households are sympathetic to demand-based tariffs, seeing as they relate to environmental issues. → Households adjust their electricity use to the price signals of demand-based tariffs. → Demand-based tariffs lead to a shift in electricity use from peak to off-peak hours. → Demand-based tariffs lead to a decrease in maximum demand in peak periods. → Magnitude of these effects increases over time.

  10. Deep influence of passive low energy consumption multi-storey residential building in cold region

    Science.gov (United States)

    Shuai, Zhang; Lihua, Zhao; Rong, Jin; Dong, Junyan

    2018-02-01

    The example of passive architecture demonstration building in Jilin Province, China, based on the practical experience of this project, the control index of passive and low energy consumption residential buildings in cold and passive buildings is referenced by reference to the German construction standard and the Chinese residence construction document, “passive ultra-low energy consumption green Building Technology Guide (Trial)”. The requirement of passive low energy residential buildings on the ground heat transfer coefficient limits is determined, and the performance requirements of passive residential buildings are discussed. This paper analyzes the requirement of the passive low energy residential building on the ground heat transfer coefficient limit, and probes into the influence factors of the ground thermal insulation of the passive low energy consumption residential building. The construction method of passive low energy consumption residential building is proposed.

  11. A Study on Electric Vehicle Heat Pump Systems in Cold Climates

    Directory of Open Access Journals (Sweden)

    Ziqi Zhang

    2016-10-01

    Full Text Available Electric vehicle heat pumps are drawing more and more attention due to their energy-saving and high efficiency designs. Some problems remain, however, in the usage of the heat pumps in electric vehicles, such as a drainage problem regarding the external heat exchangers while in heat pump mode, and the decrease in heating performance when operated in a cold climate. In this article, an R134a economized vapor injection (EVI heat pump system was built and tested. The drainage problem common amongst external heat exchangers was solved by an optimized 5 mm diameter tube-and-fin heat exchanger, which can meet both the needs of a condenser and evaporator based on simulation and test results. The EVI system was also tested under several ambient temperatures. It was found that the EVI was a benefit to the system heating capacity. Under a −20 °C ambient temperature, an average improvement of 57.7% in heating capacity was achieved with EVI and the maximum capacity was 2097 W, with a coefficient of performance (COP of 1.25. The influences of injection pressure and economizer capacity are also discussed in this article.

  12. Influence of electrical and hybrid heating on bread quality during baking.

    Science.gov (United States)

    Chhanwal, N; Ezhilarasi, P N; Indrani, D; Anandharamakrishnan, C

    2015-07-01

    Energy efficiency and product quality are the key factors for any food processing industry. The aim of the study was to develop energy and time efficient baking process. The hybrid heating (Infrared + Electrical) oven was designed and fabricated using two infrared lamps and electric heating coils. The developed oven can be operated in serial or combined heating modes. The standardized baking conditions were 18 min at 220°C to produce the bread from hybrid heating oven. Effect of baking with hybrid heating mode (H-1 and H-2, hybrid oven) on the quality characteristics of bread as against conventional heating mode (C-1, pilot scale oven; C-2, hybrid oven) was studied. The results showed that breads baked in hybrid heating mode (H-2) had higher moisture content (28.87%), higher volume (670 cm(3)), lower crumb firmness value (374.6 g), and overall quality score (67.0) comparable to conventional baking process (68.5). Moreover, bread baked in hybrid heating mode showed 28% reduction in baking time.

  13. Profits or preferences? Assessing the adoption of residential solar thermal technologies

    International Nuclear Information System (INIS)

    Mills, Bradford F.; Schleich, Joachim

    2009-01-01

    Solar thermal technologies offer the potential to meet a substantial share of residential water and space heating needs in the EU, but current levels of adoption are low. This paper uses data from a large sample of German households to assess the effects of geographic, residence, and household characteristics on the adoption of solar thermal water and space heating technologies. In addition, the impact of solar thermal technology adoption on household energy expenditures is estimated after controlling for observed household heterogeneity in geographic, residential, and household characteristics. While evidence is found of moderate household energy expenditure savings from combined solar water and space heating systems, the findings generally confirm that low in-home energy cost savings and fixed housing stocks limit the diffusion of residential solar thermal technologies. Little evidence is found of differential adoption by distinct socio-economic groups.

  14. Coupled heat-electromagnetic simulation of inductive charging stations for electric vehicles

    NARCIS (Netherlands)

    Kaufmann, C.; Günther, M.; Klagges, D.; Richwin, M.; Schöps, S.; Maten, ter E.J.W.

    2012-01-01

    Coupled electromagnetic-heat problems have been studied for induction or inductive heating, for dielectric heating, for testing of corrosion, for detection of cracks, for hardening of steel, and more recently for inductive charging of electric vehicles. In nearly all cases a simple co-simulation is

  15. Coupled heat-electromagnetic simulation of inductive charging stations for electric vehicles

    NARCIS (Netherlands)

    Kaufmann, C.; Günther, M.; Klagges, D.; Richwin, M.; Schöps, S.; Maten, ter E.J.W.; Fontes, M.; Günther, M.; Marheineke, N.

    2014-01-01

    Coupled electromagnetic-heat problems have been studied for induction or inductive heating, for dielectric heating, for testing of corrosion, for detection of cracks, for hardening of steel, and more recently for inductive charging of electric vehicles. In nearly all cases a simple co-simulation is

  16. Conservation in the residential sector: two alternatives as strategies for ordering the market

    International Nuclear Information System (INIS)

    Lins, M.E.

    1990-01-01

    This work purposes an economic flow analysis in order to be driven conservation strategies by the electric sector. Two strategies for three conservation measures are considered here in the residential sector. The results obtained increase the reliability of an action plan to be elaborated for the electric energy conservation in the residential sector. (author)

  17. Electric control of the heat flux through electrophononic effects

    Science.gov (United States)

    Seijas-Bellido, Juan Antonio; Aramberri, Hugo; Íñiguez, Jorge; Rurali, Riccardo

    2018-05-01

    We demonstrate a fully electric control of the heat flux, which can be continuously modulated by an externally applied electric field in PbTiO3, a prototypical ferroelectric perovskite, revealing the mechanisms by which experimentally accessible fields can be used to tune the thermal conductivity by as much as 50% at room temperature.

  18. Heat transfer coefficient in pool boiling for an electrically heated tube at various inclinations

    International Nuclear Information System (INIS)

    Fahmy, A.S.A.; Mariy, A.H.; Mahmoud, S.I.; Ibrahim, N.A.

    1987-01-01

    An experimental investigation is carried out study the behaviour of heat transfer in pool boiling from a vertical and inclined heated tube at atmospheric pressure. An imperial correlation joining the different parameters affecting the heat transfer coefficient in pool boiling for an electrically heated tube at various inclinations is developed. Two test sections (zircaloy-4 and stainless steel) of 16 n n outer diameter and 120 nm length are investigated. Four levels of heat flux are used for heating the two lest sections (e.g. 381, 518, 721 and 929 k.watt/n 2). The maximum surface temperature achieved is 146.5 degree c for both materials, and the maximum bulk temperature is 95 degree C. It is found that the average heat transfer coefficient is inversely proportional with heated length l, where it reaches a constant value in the horizontal position. The heat transfer coefficient curves at various inclinations with respect to the heated tube length pass around one point which is defined as limit length

  19. An overall assessment of the responsiveness of households to time-of-use electricity rates: The Ontario experiment

    International Nuclear Information System (INIS)

    Mountain, D.C.

    1993-01-01

    From 1982 to 1988, Ontario Hydro conducted an experiment in residential time-of-use pricing. A selection of households was offered one of 14 time-of-use treatments and each was monitored for electricity consumption on a 15-minute basis. The different rate structures were designed to reflect time variations in future system and distribution costs, both at the bulk and at the municipal level. Results were analyzed in terms of econometric models which to date have yielded information on the experimental changes in residential load shapes resulting from the time-of-use rates. The results are presented in the form of economic elasticities, percentage impacts, load changes at the household level, and simulated province-wide load changes. Also included are comparisons of results with other jurisdictions, comparisons of impacts on households with and without electric heating and with and without air conditioning, and comparisons across rate treatments with varying lengths of peak periods and relative prices. A fundamental conclusion is that time-of-use electricity rates do make a difference in residential load shapes. 17 refs., 8 tabs

  20. Size and importance of small electrical end uses in households

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, J R; Zogg, R A; Alberino, D L

    1998-07-01

    Miscellaneous end uses (an energy-consumption category in the residential sector) has recently emerged with more importance than ever before. Miscellaneous end uses are a collection of numerous end uses (often unrelated in technology or market characteristics) that individually are small consumers but when grouped together can become notable in size. The Annual Energy Outlook 1998, published by the Energy Information Administration (EIA), suggests that about 32% of residential electricity use in 1996 is attributable to miscellaneous end uses (21% from the Other Uses category and 11% from other miscellaneous categories). The EIA predicts this consumption will grow to about 47% of residential electricity use by 2010. Other studies have shown substantial consumption in this category, and forecast substantial future growth as well. However, it is not clear that the current accounting structure of the miscellaneous category is the most appropriate one, nor that the forecast growth in consumption will materialize. A bottom-up study on a collection of miscellaneous electric end uses was performed to better understand this complex, ill-defined category. Initial results show that many end uses can be categorized more appropriately, such as furnace fans, which belong in Space Heating. A recommended categorization reduces the Other Uses category from 21% to 12% of electric consumption estimated in 1996. Thus, the consumption from miscellaneous end uses is not nearly as large as thought. Furthermore, the growth rate associated with small end uses is projected to be lower relative to projections from other sources.

  1. Quantification of emissions from domestic heating in residential areas of İzmir, Turkey and assessment of the impact on local/regional air-quality

    Energy Technology Data Exchange (ETDEWEB)

    Sari, Deniz, E-mail: deniz.sari@tubitak.gov.tr [TUBITAK Marmara Research Center, Environment and Cleaner Production Institute, 41470 Kocaeli (Turkey); Bayram, Abdurrahman [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eylul University, Kaynaklar Campus, 35160 Buca, Izmir (Turkey)

    2014-08-01

    Air pollution in cities is a major environmental problem principally in the developing countries. The quantification of emissions is a basic requirement to assess the human influence to the atmosphere. The air quality generally shows decreases with the major contribution residential emissions and meteorology in the winter season in the big cities. Poor meteorological conditions especially inversion events for the efficient mixing of air pollutants occurred during the winter months in İzmir. With this work we quantify the amount of domestic heating emissions for particulate matter (PM10), sulfur dioxides (SO{sub 2}), nitrogen dioxides (NO{sub 2}), volatile organic compounds (VOC) and carbon monoxide (CO) together with greenhouse gases which are carbon dioxide (CO{sub 2}), nitrous oxide (N{sub 2}O) and methane (CH{sub 4}) in İzmir for 2008–2009 winter season. The results showed that the most affected residential areas were central districts in the city center from domestic heating emissions due to meteorological condition and demographic reasons. Air quality modeling is a great tool for assisting policy makers how to decrease emissions and improve air quality. At the second part of the study, calculated emissions were modeled by using CALMET/CALPUFF dispersion modeling system and plotted in the form of air pollution maps by using geographical information system to determine the locations and estimate the effects of the new residential areas that will be established in the future in İzmir. - Highlights: • The air pollution in cities especially shows raises with the opening of winter season. • Air pollution has become a problem due to rapid urbanization in İzmir, Turkey. • The air quality shows decreases with the residential emissions in İzmir's winter. • With this work we quantify the amount of domestic heating emissions for pollutants. • The impact of emissions on local air-quality is determined by using dispersion model.

  2. Renewable Energy and Energy Efficiency Technologies in Residential Building Codes: June 15, 1998 to September 15, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Wortman, D.; Echo-Hawk, L.

    2005-02-01

    This report is an attempt to describe the building code requirements and impediments to the application of EE and RE technologies in residential buildings. Several modern model building codes were reviewed. These are representative of the codes that will be adopted by most locations in the coming years. The codes reviewed for this report include: International Residential Code, First Draft, April 1998; International Energy Conservation Code, 1998; International Mechanical Code, 1998; International Plumbing Code, 1997; International Fuel Gas Code, 1997; National Electrical Code, 1996. These codes were reviewed as to their application to (1) PV systems in buildings and building-integrated PV systems and (2) active solar domestic hot water and space-heating systems. A discussion of general code issues that impact these technologies is also included. Examples of this are solar access and sustainability.

  3. Energy-Saving Sintering of Electrically Conductive Powders by Modified Pulsed Electric Current Heating Using an Electrically Nonconductive Die

    Science.gov (United States)

    Ito, Mikio; Kawahara, Kenta; Araki, Keita

    2014-04-01

    Sintering of Cu and thermoelectric Ca3Co4O9 was tried using a modified pulsed electric current sintering (PECS) process, where an electrically nonconductive die was used instead of a conventional graphite die. The pulsed electric current flowed through graphite punches and sample powder, which caused the Joule heating of the powder compact itself, resulting in sintering under smaller power consumption. Especially for the Ca3Co4O9 powder, densification during sintering was also accelerated by this modified PECS process.

  4. Composite electric generator equipped with steam generator for heating reactor coolant

    International Nuclear Information System (INIS)

    Watabe, Masaharu; Soman, Yoshindo; Kawanishi, Kohei; Ota, Masato.

    1997-01-01

    The present invention concerns a composite electric generator having coolants, as a heating source, of a PWR type reactor or a thermonuclear reactor. An electric generator driving gas turbine is disposed, and a superheater using a high temperature exhaust gas of the gas turbine as a heating source is disposed, and main steams are superheated by the superheater to elevate the temperature at the inlet of the turbine. This can increase the electric generation capacity as well as increase the electric generation efficiency. In addition, since the humidity in the vicinity of the exit of the steam turbine is reduced, occurrence of loss and erosion can be suppressed. When cooling water of the thermonuclear reactor is used, the electric power generated by the electric generator driven by the gas turbine can be used upon start of the thermonuclear reactor, and it is not necessary to dispose a large scaled special power source in the vicinity, which is efficient. (N.H.)

  5. Priestley's Shadow and Lavoisier's Influence: Electricity and Heat in the Late Eighteenth and Early Nineteenth Centuries

    Science.gov (United States)

    Fisher, Amy

    In the late eighteenth century, Joseph Priestley argued that any complete theory of heat also had to explain electrical phenomena, which manifested many similar effects to heat. For example, sparking or heating a sample of trapped air caused a reduction in the volume of air and made the gas toxic to living organisms. Because of the complexity of electrical and thermal phenomena, Antoine Lavoisier did not address electrical action in his published works. Rather, he focused on those effects produced by heating alone. With the success of Lavoisier's caloric theory of heat, natural philosophers and chemists continued to debate the relationship between heat and electricity. In this presentation, I compare and contrast the fate of caloric in early-nineteenth-century electrical studies via the work of two scientists: Humphry Davy in Britain and Robert Hare in America.

  6. Applicability of Related Data, Algorithms, and Models to the Simulation of Ground-Coupled Residential Hot Water Piping in California

    International Nuclear Information System (INIS)

    Warner, J.L.; Lutz, J.D.

    2006-01-01

    Residential water heating is an important consideration in California?s building energy efficiency standard. Explicit treatment of ground-coupled hot water piping is one of several planned improvements to the standard. The properties of water, piping, insulation, backfill materials, concrete slabs, and soil, their interactions, and their variations with temperature and over time are important considerations in the required supporting analysis. Heat transfer algorithms and models devised for generalized, hot water distribution system, ground-source heat pump and ground heat exchanger, nuclear waste repository, buried oil pipeline, and underground electricity transmission cable applications can be adapted to the simulation of under-slab water piping. A numerical model that permits detailed examination of and broad variations in many inputs while employing a technique to conserve computer run time is recommended.

  7. Information campaign on solar heating for houses heated by electricity

    International Nuclear Information System (INIS)

    West, M.

    1995-09-01

    A number of NESA's (Danish electric power company) customers were offered the use of a solar water heating system for a short period of time. NESA was responsible for the marketing and consultancy service and worked in cooperation with local plumbers in connection with the delivery of the systems. The company contacted 450 households and its representatives visited 25 of these. 4 customers decided to purchase a solar heating system, fourteen decided to think about it, and four declared that they would not buy one. The company had reckoned with 25 purchases. It is concluded that the price of the solar heating systems was too high for prospective customers and the fact that they were not given a special offer had a negative effect. The economic aspect was absolutely the most important for them, especially the length of the payback period on the higher purchase system. Environmental protection aspects came second in their deliberations. NESA has a positive attitude to their customers' use of solar heating plants and recommends that households are offered very high quality consultancy services in connection with marketing. The project is described in detail. (AB)

  8. Efficient thermo-mechanical generation of electricity from the heat of radioisotopes

    International Nuclear Information System (INIS)

    Cooke-Yarborough, E.H.; Yeats, F.W.

    1975-01-01

    The thermomechanical generator uses a thermomechanical oscillator to convert heat efficiently into a mechanical oscillation which in turn excites a suitable transducer to generate alternating electricity. The thermomechanical oscillator used is based on the Stirling cycle, but avoids the need for rotary motion and for sliding pistons by having a mechanically-resonant, spring-suspended displacer, and by using an oscillating metal diaphragm to provide the mechanical output. The diaphragm drives an alternator consisting of a spring-suspended permanent magnet oscillating between fixed pole pieces which carry the electrical power output windings. Because a thermomechanical generator is much more efficient than a thermo-electric generator at comparable temperatures, it is particularly suitable for use with a radioisotope heat source. The amounts of radioisotope and of shielding required are both greatly reduced. A machine heated by radioisotopes and delivering 10.7W ac at 80Hz began operating in October, 1974. Operating experience with this machine is reported, and these results, together with those obtained with higher-powered machines heated by other means, are used to calculate characteristics and performance of thermo-mechanical radioisotope generators capable of using heat sources such as the waste-management 90 Sr radioisotope sources becoming available from the US nuclear waste management programme. A design to use one of these heat sources in a 52-W underwater generator is described

  9. Drought and Heat Wave Impacts on Electricity Grid Reliability in Illinois

    Science.gov (United States)

    Stillwell, A. S.; Lubega, W. N.

    2016-12-01

    A large proportion of thermal power plants in the United States use cooling systems that discharge large volumes of heated water into rivers and cooling ponds. To minimize thermal pollution from these discharges, restrictions are placed on temperatures at the edge of defined mixing zones in the receiving waters. However, during extended hydrological droughts and heat waves, power plants are often granted thermal variances permitting them to exceed these temperature restrictions. These thermal variances are often deemed necessary for maintaining electricity reliability, particularly as heat waves cause increased electricity demand. Current practice, however, lacks tools for the development of grid-scale operational policies specifying generator output levels that ensure reliable electricity supply while minimizing thermal variances. Such policies must take into consideration characteristics of individual power plants, topology and characteristics of the electricity grid, and locations of power plants within the river basin. In this work, we develop a methodology for the development of these operational policies that captures necessary factors. We develop optimal rules for different hydrological and meteorological conditions, serving as rule curves for thermal power plants. The rules are conditioned on leading modes of the ambient hydrological and meteorological conditions at the different power plant locations, as the locations are geographically close and hydrologically connected. Heat dissipation in the rivers and cooling ponds is modeled using the equilibrium temperature concept. Optimal rules are determined through a Monte Carlo sampling optimization framework. The methodology is applied to a case study of eight power plants in Illinois that were granted thermal variances in the summer of 2012, with a representative electricity grid model used in place of the actual electricity grid.

  10. Tariffs for natural gas, heat, electricity and cogeneration in 1998

    International Nuclear Information System (INIS)

    1998-03-01

    The rate of return of the combined generation of heat and power is not only determined by the capital expenditures and the costs of maintenance, control, management and insurance, but also by the fuel costs of the cogeneration installation and the avoided fuel costs in case of separated heat production, the avoided/saved costs of electricity purchase, and the compensation for possible supply to the public grid (sellback). This brochure aims at providing information about the structure of natural gas and electricity tariffs to be able to determine the three last-mentioned expenditures. First, attention is paid to the tariffs of natural gas for large-scale consumers, the tariff for cogeneration and horticulture, and natural gas supply contracts. Next, the structure of the electricity tariffs is dealt with in detail, discussing the accounting system within the electric power sector, the tariffs and compensations for large-scale consumers and specific large-scale consumers, electricity sellback tariffs, and compensations for reserve capacity. Also attention will be paid to tariffs for electricity transport. Finally, several taxes, excises and levies that have a direct or indirect impact on natural gas tariffs, are discussed. 9 refs

  11. Research on Heat Dissipation of Electric Vehicle Based on Safety Architecture Optimization

    Science.gov (United States)

    Zhou, Chao; Guo, Yajuan; Huang, Wei; Jiang, Haitao; Wu, Liwei

    2017-10-01

    In order to solve the problem of excessive temperature in the discharge process of lithium-ion battery and the temperature difference between batteries, a heat dissipation of electric vehicle based on safety architecture optimization is designed. The simulation is used to optimize the temperature field of the heat dissipation of the battery. A reasonable heat dissipation control scheme is formulated to achieve heat dissipation requirements. The results show that the ideal working temperature range of the lithium ion battery is 20?∼45?, and the temperature difference between the batteries should be controlled within 5?. A cooling fan is arranged at the original air outlet of the battery model, and the two cooling fans work in turn to realize the reciprocating flow. The temperature difference is controlled within 5? to ensure the good temperature uniformity between the batteries of the electric vehicle. Based on the above finding, it is concluded that the heat dissipation design for electric vehicle batteries is safe and effective, which is the most effective methods to ensure battery life and vehicle safety.

  12. Micro-CHP Systems for Residential Applications

    Energy Technology Data Exchange (ETDEWEB)

    Timothy DeValve; Benoit Olsommer

    2007-09-30

    Integrated micro-CHP (Cooling, Heating and Power) system solutions represent an opportunity to address all of the following requirements at once: conservation of scarce energy resources, moderation of pollutant release into our environment, and assured comfort for home-owners. The objective of this effort was to establish strategies for development, demonstration, and sustainable commercialization of cost-effective integrated CHP systems for residential applications. A unified approach to market and opportunity identification, technology assessment, specific system designs, adaptation to modular product platform component conceptual designs was employed. UTRC's recommendation to U.S. Department of Energy is to go ahead with the execution of the proposed product development and commercialization strategy plan under Phase II of this effort. Recent indicators show the emergence of micro-CHP. More than 12,000 micro-CHP systems have been sold worldwide so far, around 7,500 in 2004. Market projections predict a world-wide market growth over 35% per year. In 2004 the installations were mainly in Europe (73.5%) and in Japan (26.4%). The market in North-America is almost non-existent (0.1%). High energy consumption, high energy expenditure, large spark-spread (i.e., difference between electricity and fuel costs), big square footage, and high income are the key conditions for market acceptance. Today, these conditions are best found in the states of New York, Pennsylvania, New Jersey, Wisconsin, Illinois, Indiana, Michigan, Ohio, New England states. A multiple stage development plan is proposed to address risk mitigation. These stages include concept development and supplier engagement, component development, system integration, system demonstration, and field trials. A two stage commercialization strategy is suggested based on two product versions. The first version--a heat and power system named Micro-Cogen, provides the heat and essential electrical power to the

  13. Price, environment and security: Exploring multi-modal motivation in voluntary residential peak demand response

    International Nuclear Information System (INIS)

    Gyamfi, Samuel; Krumdieck, Susan

    2011-01-01

    Peak demand on electricity grids is a growing problem that increases costs and risks to supply security. Residential sector loads often contribute significantly to seasonal and daily peak demand. Demand response projects aim to manage peak demand by applying price signals and automated load shedding technologies. This research investigates voluntary load shedding in response to information about the security of supply, the emission profile and the cost of meeting critical peak demand in the customers' network. Customer willingness to change behaviour in response to this information was explored through mail-back survey. The diversified demand modelling method was used along with energy audit data to estimate the potential peak load reduction resulting from the voluntary demand response. A case study was conducted in a suburb of Christchurch, New Zealand, where electricity is the main source for water and space heating. On this network, all water heating cylinders have ripple-control technology and about 50% of the households subscribe to differential day/night pricing plan. The survey results show that the sensitivity to supply security is on par with price, with the emission sensitivity being slightly weaker. The modelling results show potential 10% reduction in critical peak load for aggregate voluntary demand response. - Highlights: → Multiple-factor behaviour intervention is necessarily for effective residential demand response. → Security signals can achieve result comparable to price. → The modelling results show potential 10% reduction in critical peak load for aggregate voluntary demand response. → New Zealand's energy policy should include innovation and development of VDR programmes and technologies.

  14. The Pacific Northwest residential consumer: Perceptions and preferences of home heating fuels, major appliances, and appliance fuels

    Energy Technology Data Exchange (ETDEWEB)

    Harkreader, S.A.; Hattrup, M.P.

    1988-09-01

    In 1983 the Bonneville Power Administration contracted with the Pacific Northwest Laboratory (PNL) to conduct an analysis of the marketing environment for Bonneville's conservation activities. Since this baseline residential study, PNL has conducted two follow up market research projects: Phase 2 in 1985, and Phase 3, in 1988. In this report the respondents' perceptions, preferences, and fuel switching possibilities of fuels for home heating and major appliances are examined. To aid in effective target marketing, the report identifies market segments according to consumers' demographics, life-cycle, attitudes, and opinions.

  15. Economics of Condensing Gas Furnaces and Water Heaters Potential in Residential Single Family Homes

    OpenAIRE

    Lekov, Alex

    2010-01-01

    Residential space and water heating accounts for over 90percent of total residential primary gas consumption in the United States. Condensing space and water heating equipment are 10-30percent more energy-efficient than conventional space and water heating. Currently, condensing gas furnaces represent 40 percent of shipments and are common in the Northern U.S. market. Meanwhile, manufacturers are planning to develop condensing gas storage water heaters to qualify for Energy Star? certificati...

  16. Design and Analysis of an Optical Coupler for Concentrated Solar Light Using Optical Fibers in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Afshin Aslian

    2016-01-01

    Full Text Available Concentrated sunlight that is transmitted by fiber optics has been used for generating electricity, heat, and daylight. On the other hand, multijunction photovoltaic cells provide high efficiency for generating electricity from highly concentrated sunlight. This study deals with designing and simulating a high-efficiency coupler, employing a mathematical model to connect sunlight with fiber optics for multiple applications. The coupler concentrates and distributes irradiated light from a primary concentrator. In this study, a parabolic dish was used as the primary concentrator, a coupler that contains nine components called a compound truncated pyramid and a cone (CTPC, all of which were mounted on a plate. The material of both the CTPC and the plate was BK7 optical glass. Fiber optics cables and multijunction photovoltaic cells were connected to the cylindrical part of the CTPC. The fibers would transmit the light to the building to provide heat and daylight, whereas multijunction photovoltaic cells generate electricity. Theoretical and simulation results showed high performance of the designed coupler. The efficiency of the coupler was as high as 92%, whereas the rim angle of the dish increased to an optimum angle. Distributed sunlight in the coupler increased the flexibility and simplicity of the design, resulting in a system that provided concentrated electricity, heat, and lighting for residential buildings.

  17. Economic valuation of heat pumps and electric boilers in the Danish energy system

    DEFF Research Database (Denmark)

    Nielsen, Maria Grønnegaard; Morales González, Juan Miguel; Zugno, Marco

    2016-01-01

    Heat pumps (HP) and electric immersion boilers (EB) have great potential to increase flexibility in energy systems. In parallel, decreasing taxes on electricity-based heat production are creating a more favorable economic environment for the deployment of these units in Denmark. In this paper, th...... by potential investors....

  18. Residential heating contribution to level of air pollutants (PAHs, major, trace, and rare earth elements): a moss bag case study.

    Science.gov (United States)

    Vuković, Gordana; Aničić Urošević, Mira; Pergal, Miodrag; Janković, Milan; Goryainova, Zoya; Tomašević, Milica; Popović, Aleksandar

    2015-12-01

    In areas with moderate to continental climates, emissions from residential heating system lead to the winter air pollution peaks. The EU legislation requires only the monitoring of airborne concentrations of particulate matter, As, Cd, Hg, Ni, and B[a]P. Transition metals and rare earth elements (REEs) have also arisen questions about their detrimental health effects. In that sense, this study examined the level of extensive set of air pollutants: 16 polycyclic aromatic hydrocarbons (PAHs), and 41 major elements, trace elements, and REEs using Sphagnum girgensohnii moss bag technique. During the winter of 2013/2014, the moss bags were exposed across Belgrade (Serbia) to study the influence of residential heating system to the overall air quality. The study was set as an extension to our previous survey during the summer, i.e., non-heating season. Markedly higher concentrations of all PAHs, Sb, Cu, V, Ni, and Zn were observed in the exposed moss in comparison to the initial values. The patterns of the moss REE concentrations normalized to North American Shale Composite and Post-Archean Australian Shales were identical across the study area but enhanced by anthropogenic activities. The results clearly demonstrate the seasonal variations in the moss enrichment of the air pollutants. Moreover, the results point out a need for monitoring of air quality during the whole year, and also of various pollutants, not only those regulated by the EU Directive.

  19. The effects of utility cost reduction on residential energy consumption in Hungary – a decomposition analysis

    Directory of Open Access Journals (Sweden)

    Tekla Sebestyén Szép

    2017-01-01

    Full Text Available The residential energy consumption is influenced by a lot of factors. Understanding and calculating these factors is essential to making conscious energy policy decisions and feedbacks. Since 2013 the energy prices for households have been controlled by the government in Hungary and as a result of the utility cost reduction program a sharp decline can be observed in residential electricity, district heating and natural gas prices. This paper applies the LMDI (~Logarithmic Mean Division Index method to decompose the absolute change of the residential energy consumption during the period of 2010-2015. We calculate the price, the intensive structure (it means the change of energy expenditure share on energy sources, the extensive structure (it is in connection with the change of energy expenditure share in total expenditure, expenditure (it is the change of per capita total expenditure and population effect. All of that shows the impact of the specific factor on the residential energy consumption by income deciles. Our results have verified the preliminary expectations: the decreasing energy prices for households have a positive impact on energy use and it has been strengthened by the expenditure effect as well. However, the intensive structure, the extensive structure and the population effect have largely offset it.

  20. Pilot plant experiments for baking of anode blocks in electrically heated ovens

    Energy Technology Data Exchange (ETDEWEB)

    Grjotheim, K. (Oslo Univ. (Norway). Dept. of Chemistry); Kvande, H. (Hydro Aluminium AS, Stabekk (Norway)); Naixiang, F.; Shiheng, Z.; An, L.; Guangxia, H. (Northeast Univ. of Technology, Shenyang, LN (China). Dept. of Non-Ferrous Metallurgy)

    1990-04-01

    Pilot plant experiments were made to bake anode blocks in electrically heated baking ovens. About 70% of the baked anodes had a specific electrical resistance between 35 and 60 {Omega}xmm{sup 2}xm{sup -1}. About 25% had higher resistances, and these were returned to the baking ovens and used as heating elements in the next baking cycle. The average electrical energy consumption was 1430 kWh per tonne of anodes produced, which is about only 60% of the energy consumption in classical oil or gas-fired baking ovens. (orig.).